1
|
Rahnama A, Vaithiyanathan M, Briceno-Mena L, Dugas TM, Yates KL, Romagnoli JA, Melvin AT. A microfluidic approach to study variations in Chlamydomonas reinhardtii alkaline phosphatase activity in response to phosphate availability. Analyst 2024; 149:4256-4266. [PMID: 38895826 DOI: 10.1039/d4an00619d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/21/2024]
Abstract
Algal growth depends strongly on phosphorus (P) as a key nutrient, underscoring the significance of monitoring P levels. Algal species display a sensitive response to fluctuations in P availability, notably through the expression of alkaline phosphatase (AP) when challenged with P-depletion. As such, alkaline phosphatase activity (APA) serves as a valuable metric for P availability, offering insights into how algae utilize and fix available P resources. However, current APA quantification methods lack single cell resolution, while also being time- and reagent consuming. Microfluidics offers a promising cost-effective solution to these limitations, providing a platform for precise single-cell analysis. In this study, a trap-based microfluidic device was integrated with a commercially available AP live stain to study the single cell APA response of a model algae strain, Chlamydomonas reinhardtii, when exposed to different exogenous P levels. A three-step culture-starve-spike process was used to induce APA in cells cultured under two different basal P levels (1 and 21 mM). When challenged with different spiked P levels (ranging from 0.1-41 mM), C. reinhardtii cells demonstrated a highly heterogeneous APA response. Two-way ANOVA confirmed that this response is influenced by both spiked and basal P levels. Utilizing an unsupervised machine learning approach (HDBSCAN), distinct subpopulations of C. reinhardtii cells were identified exhibiting varying levels of APA at the single-cell level. These subpopulations encompass significant groups of individual cells with either notably high or low APA, contributing to the overall behavior of the cohorts. Considerable intrapopulation differences in APA were observed across cohorts with similar average behavior. For instance, while some cohorts exhibited a concentrated distribution around the overall average APA, others displayed subpopulations dispersed across a wider range of APA levels. This underscores the potential bias introduced by analyzing a small number of cells in bulk, which may skew results by overrepresenting extreme behavioral subpopulations. The findings if this study highlight the need for analytical approaches that account for single cell heterogeneity in APA and demonstrate the utility of microfluidics as a well-suited means for such investigations. This study illuminates the complexities of APA regulation at the single cell level, providing crucial insights that advance our understanding of algal phosphorus metabolism and environmental responses.
Collapse
Affiliation(s)
- Alireza Rahnama
- Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, Louisiana, 70803, USA.
| | - Manibarathi Vaithiyanathan
- Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, Louisiana, 70803, USA.
| | - Luis Briceno-Mena
- Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, Louisiana, 70803, USA.
| | - Travis M Dugas
- Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, Louisiana, 70803, USA.
| | - Kelly L Yates
- Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, Louisiana, 70803, USA.
| | - Jose A Romagnoli
- Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, Louisiana, 70803, USA.
| | - Adam T Melvin
- Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, Louisiana, 70803, USA.
- Department of Chemical and Biomolecular Engineering, Clemson University, Clemson, South Carolina, 29634, USA
| |
Collapse
|
2
|
Rasekh M, Harrison S, Schobesberger S, Ertl P, Balachandran W. Reagent storage and delivery on integrated microfluidic chips for point-of-care diagnostics. Biomed Microdevices 2024; 26:28. [PMID: 38825594 DOI: 10.1007/s10544-024-00709-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/02/2024] [Indexed: 06/04/2024]
Abstract
Microfluidic-based point-of-care diagnostics offer several unique advantages over existing bioanalytical solutions, such as automation, miniaturisation, and integration of sensors to rapidly detect on-site specific biomarkers. It is important to highlight that a microfluidic POC system needs to perform a number of steps, including sample preparation, nucleic acid extraction, amplification, and detection. Each of these stages involves mixing and elution to go from sample to result. To address these complex sample preparation procedures, a vast number of different approaches have been developed to solve the problem of reagent storage and delivery. However, to date, no universal method has been proposed that can be applied as a working solution for all cases. Herein, both current self-contained (stored within the chip) and off-chip (stored in a separate device and brought together at the point of use) are reviewed, and their merits and limitations are discussed. This review focuses on reagent storage devices that could be integrated with microfluidic devices, discussing further issues or merits of these storage solutions in two different sections: direct on-chip storage and external storage with their application devices. Furthermore, the different microvalves and micropumps are considered to provide guidelines for designing appropriate integrated microfluidic point-of-care devices.
Collapse
Affiliation(s)
- Manoochehr Rasekh
- College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge, UB8 3PH, UK.
| | - Sam Harrison
- College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge, UB8 3PH, UK
| | - Silvia Schobesberger
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9, 1060, Vienna, Austria
| | - Peter Ertl
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9, 1060, Vienna, Austria
| | - Wamadeva Balachandran
- College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge, UB8 3PH, UK.
| |
Collapse
|
3
|
Amirian H, Dalvand K, Ghiasvand A. Seamless integration of Internet of Things, miniaturization, and environmental chemical surveillance. ENVIRONMENTAL MONITORING AND ASSESSMENT 2024; 196:582. [PMID: 38806872 DOI: 10.1007/s10661-024-12698-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 04/30/2024] [Indexed: 05/30/2024]
Abstract
IoT is a game-changer across all fields, including chemistry. Embracing sustainable practices and green chemistry, the miniaturization and automation of systems, and their integration into IoT is key to achieving these principles, as a rising trend with momentum. Particularly, IoT and analytical chemistry are linked in the rapid exchange of analytical data for environmental, industrial, healthcare, and educational applications. Meanwhile, cooperation with other fields of science is evident, and there is a prompt and subjective analysis of information related to analytical systems and methodologies. This paper will review the concepts, requirements, and architecture of IoT and its role in the miniaturization and automation of analytical tools using electronic modules and sensors. The aim is to explore the standards and perspectives of IoT and its interaction with different aspects of analytical chemistry. Additionally, it aimed to explain the basics and applications of IoT for chemists, and its relevance to different subfields of analytical chemistry, particularly in the field of environmental chemical surveillance. The article also covers updating IoT devices and creating DIY-based degradation devices to enhance the educational aspect of chemistry and reduce barriers to lab facilities and equipment. Lastly, it will explore how IoT is really important and how it's going to significantly impact analytical chemistry.
Collapse
Affiliation(s)
- Hamzeh Amirian
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran
| | - Kolsoum Dalvand
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran
| | - Alireza Ghiasvand
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran.
| |
Collapse
|
4
|
Ji J, Hu C, Pang X, Liang J, Huang Q, Hu S, Mei Q, Ma H. Open Thermal Control System for Stable Polymerase Chain Reaction on a Digital Microfluidic Chip. ACS OMEGA 2024; 9:10937-10944. [PMID: 38463286 PMCID: PMC10918803 DOI: 10.1021/acsomega.3c10312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Revised: 01/31/2024] [Accepted: 02/07/2024] [Indexed: 03/12/2024]
Abstract
In this paper, a digital microfluidic thermal control system was introduced for the stable polymerase chain reaction (PCR). The system consists of a thermoelectric cooler unit, a thermal control board, and graphical-user-interface software capable of simultaneously achieving temperature control and on-chip droplet observation. A fuzzy proportional-integral-derivative (PID) method was developed for this system. The simulation analysis was performed to evaluate the temperature of different reagents within the chip. Based on the results, applying fuzzy PID control for PCR will enhance the thermal stability by 67.8% and save the time by 1195 s, demonstrating excellent dynamic response capability and thermal robustness. The experimental results are consistent with the simulation results on the planar temperature distribution, with a data consistency rate of over 99%. The PCR validation was carried out on this system, successfully amplifying the rat GAPDH gene at a concentration of 193 copies/μL. This work has the potential to be useful in numerous existing lab-on-a-chip applications.
Collapse
Affiliation(s)
- Jiajian Ji
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- CAS Key Laboratory of Biomedical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences (CAS), Suzhou 215163, China
| | - Chenxuan Hu
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- CAS Key Laboratory of Biomedical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences (CAS), Suzhou 215163, China
| | - Xinpei Pang
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- CAS Key Laboratory of Biomedical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences (CAS), Suzhou 215163, China
| | - Jiancong Liang
- Guangdong ACXEL Micro & Nano Tech Co., Ltd, Foshan 528200, China
| | - Qi Huang
- CAS Key Laboratory of Biomedical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences (CAS), Suzhou 215163, China
| | - Siyi Hu
- CAS Key Laboratory of Biomedical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences (CAS), Suzhou 215163, China
| | - Qian Mei
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- CAS Key Laboratory of Biomedical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences (CAS), Suzhou 215163, China
| | - Hanbin Ma
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- CAS Key Laboratory of Biomedical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences (CAS), Suzhou 215163, China
| |
Collapse
|
5
|
Ma X, Guo G, Wu X, Wu Q, Liu F, Zhang H, Shi N, Guan Y. Advances in Integration, Wearable Applications, and Artificial Intelligence of Biomedical Microfluidics Systems. MICROMACHINES 2023; 14:mi14050972. [PMID: 37241596 DOI: 10.3390/mi14050972] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 04/20/2023] [Accepted: 04/25/2023] [Indexed: 05/28/2023]
Abstract
Microfluidics attracts much attention due to its multiple advantages such as high throughput, rapid analysis, low sample volume, and high sensitivity. Microfluidics has profoundly influenced many fields including chemistry, biology, medicine, information technology, and other disciplines. However, some stumbling stones (miniaturization, integration, and intelligence) strain the development of industrialization and commercialization of microchips. The miniaturization of microfluidics means fewer samples and reagents, shorter times to results, and less footprint space consumption, enabling a high throughput and parallelism of sample analysis. Additionally, micro-size channels tend to produce laminar flow, which probably permits some creative applications that are not accessible to traditional fluid-processing platforms. The reasonable integration of biomedical/physical biosensors, semiconductor microelectronics, communications, and other cutting-edge technologies should greatly expand the applications of current microfluidic devices and help develop the next generation of lab-on-a-chip (LOC). At the same time, the evolution of artificial intelligence also gives another strong impetus to the rapid development of microfluidics. Biomedical applications based on microfluidics normally bring a large amount of complex data, so it is a big challenge for researchers and technicians to analyze those huge and complicated data accurately and quickly. To address this problem, machine learning is viewed as an indispensable and powerful tool in processing the data collected from micro-devices. In this review, we mainly focus on discussing the integration, miniaturization, portability, and intelligence of microfluidics technology.
Collapse
Affiliation(s)
- Xingfeng Ma
- School of Communication and Information Engineering, Shanghai University, Shanghai 200000, China
- Department of Microelectronics, Shanghai University, Shanghai 200000, China
| | - Gang Guo
- Department of Microelectronics, Shanghai University, Shanghai 200000, China
| | - Xuanye Wu
- Department of Microelectronics, Shanghai University, Shanghai 200000, China
- Shanghai Industrial μTechnology Research Institute, Shanghai 200000, China
| | - Qiang Wu
- Shanghai Aure Technology Limited Company, Shanghai 200000, China
| | - Fangfang Liu
- Shanghai Industrial μTechnology Research Institute, Shanghai 200000, China
| | - Hua Zhang
- Shanghai Aure Technology Limited Company, Shanghai 200000, China
| | - Nan Shi
- Shanghai Industrial μTechnology Research Institute, Shanghai 200000, China
- Institute of Translational Medicine, Shanghai University, Shanghai 200000, China
| | - Yimin Guan
- Department of Microelectronics, Shanghai University, Shanghai 200000, China
- Shanghai Aure Technology Limited Company, Shanghai 200000, China
| |
Collapse
|
6
|
Shi J, Zhang Y, Yang M. Recent development of microfluidics-based platforms for respiratory virus detection. BIOMICROFLUIDICS 2023; 17:024104. [PMID: 37035101 PMCID: PMC10076069 DOI: 10.1063/5.0135778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Accepted: 02/27/2023] [Indexed: 06/19/2023]
Abstract
With the global outbreak of SARS-CoV-2, the inadequacies of current detection technology for respiratory viruses have been recognized. Rapid, portable, accurate, and sensitive assays are needed to expedite diagnosis and early intervention. Conventional methods for detection of respiratory viruses include cell culture-based assays, serological tests, nucleic acid detection (e.g., RT-PCR), and direct immunoassays. However, these traditional methods are often time-consuming, labor-intensive, and require laboratory facilities, which cannot meet the testing needs, especially during pandemics of respiratory diseases, such as COVID-19. Microfluidics-based techniques can overcome these demerits and provide simple, rapid, accurate, and cost-effective analysis of intact virus, viral antigen/antibody, and viral nucleic acids. This review aims to summarize the recent development of microfluidics-based techniques for detection of respiratory viruses. Recent advances in different types of microfluidic devices for respiratory virus diagnostics are highlighted, including paper-based microfluidics, continuous-flow microfluidics, and droplet-based microfluidics. Finally, the future development of microfluidic technologies for respiratory virus diagnostics is discussed.
Collapse
Affiliation(s)
- Jingyu Shi
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Kowloon 999077, Hong Kong SAR, People's Republic of China
| | - Yu Zhang
- Department of Mechanical and Automotive Engineering, Royal Melbourne Institute of Technology, Melbourne, VIC 3000, Australia
| | - Mo Yang
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Kowloon 999077, Hong Kong SAR, People's Republic of China
| |
Collapse
|
7
|
Lin X, Wu H, Zeng S, Peng T, Zhang P, Wan X, Lang Y, Zhang B, Jia Y, Shen R, Yin B. A self-designed device integrated with a Fermat spiral microfluidic chip for ratiometric and automated point-of-care testing of anthrax biomarker in real samples. Biosens Bioelectron 2023; 230:115283. [PMID: 37019031 DOI: 10.1016/j.bios.2023.115283] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 03/12/2023] [Accepted: 03/28/2023] [Indexed: 04/03/2023]
Abstract
A desirable lanthanide-based ratiometric fluorescent probe was designed and integrated into a self-designed Fermat spiral microfluidic chip (FS-MC) for the automated determination of a unique bacterial endospore biomarker, dipicolinic acid (DPA), with high selectivity and sensitivity. Here, a blue emission wavelength at 425 nm was generated in the Fermat spiral structure by mixing the europium (Eu3+) and luminol to form the Eu3+/Luminol sensing probe. DPA in the reservoir can be used to specifically bind to Eu3+ under the negative pressure and transfer energy from DPA to Eu3+ sequentially via an antenna effect, thus resulting in a significant increase in the red fluorescence emission peak at 615 nm. According to the fluorescence intensity ratio (F615/F425), a good linearity can be obtained with increasing the concentration of DPA from 0 to 200 μM with a limit of detection as low as 10.11 nM. Interestingly, the designed FS-MC can achieve rapid detection of DPA in only 1 min, reducing detection time and improving sensitivity. Furthermore, a self-designed device integrated with the FS-MC and a smartphone color picker APP was employed for the rapid automatic point-of-care testing (POCT) of DPA in the field, simplifying complex processes and reducing testing times, thus confirming the great promise of this ready-to-use measurement platform for in situ inspection.
Collapse
|
8
|
Sinha N, Yang H, Janse D, Hendriks L, Rand U, Hauser H, Köster M, van de Vosse FN, de Greef TFA, Tel J. Microfluidic chip for precise trapping of single cells and temporal analysis of signaling dynamics. COMMUNICATIONS ENGINEERING 2022; 1:18. [PMCID: PMC10955935 DOI: 10.1038/s44172-022-00019-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Accepted: 07/12/2022] [Indexed: 06/15/2024]
Abstract
Microfluidic designs are versatile examples of technology miniaturisation that find their applications in various cell biology research, especially to investigate the influence of environmental signals on cellular response dynamics. Multicellular systems operate in intricate cellular microenvironments where environmental signals govern well-orchestrated and robust responses, the understanding of which can be realized with integrated microfluidic systems. In this study, we present a fully automated and integrated microfluidic chip that can deliver input signals to single and isolated suspension or adherent cells in a precisely controlled manner. In respective analyses of different single cell types, we observe, in real-time, the temporal dynamics of caspase 3 activation during DMSO-induced apoptosis in single cancer cells (K562) and the translocation of STAT-1 triggered by interferon γ (IFNγ) in single fibroblasts (NIH3T3). Our investigations establish the employment of our versatile microfluidic system in probing temporal single cell signaling networks where alternations in outputs uncover signal processing mechanisms. Nidhi Sinha, Haowen Yang and colleagues report a microfluidic large-scale integration chip to probe temporal single-cell signalling networks via the delivery of patterns of input signalling molecules. The researchers use their device to investigate drug-induced cancer cell apoptosis and single cell transcription (STAT-1) protein signalling dynamics.
Collapse
Affiliation(s)
- Nidhi Sinha
- Laboratory of Immunoengineering, Department of Biomedical Engineering, TU Eindhoven, 5600 MB Eindhoven, Netherlands
- Institute of Complex Molecular Systems, TU Eindhoven, 5600 MB Eindhoven, Netherlands
| | - Haowen Yang
- Laboratory of Immunoengineering, Department of Biomedical Engineering, TU Eindhoven, 5600 MB Eindhoven, Netherlands
- Institute of Complex Molecular Systems, TU Eindhoven, 5600 MB Eindhoven, Netherlands
| | - David Janse
- Laboratory of Immunoengineering, Department of Biomedical Engineering, TU Eindhoven, 5600 MB Eindhoven, Netherlands
| | - Luc Hendriks
- Laboratory of Immunoengineering, Department of Biomedical Engineering, TU Eindhoven, 5600 MB Eindhoven, Netherlands
| | - Ulfert Rand
- Model Systems for Infection and Immunity, Helmholtz Centre for Infection Research, 38124 Braunschweig, Germany
| | - Hansjörg Hauser
- Model Systems for Infection and Immunity, Helmholtz Centre for Infection Research, 38124 Braunschweig, Germany
| | - Mario Köster
- Model Systems for Infection and Immunity, Helmholtz Centre for Infection Research, 38124 Braunschweig, Germany
| | - Frans N. van de Vosse
- Cardiovascular Biomechanics Group, Department of Biomedical Engineering, TU Eindhoven, 5600 MB Eindhoven, Netherlands
| | - Tom F. A. de Greef
- Institute of Complex Molecular Systems, TU Eindhoven, 5600 MB Eindhoven, Netherlands
- Computational Biology Group, Department of Biomedical Engineering, TU Eindhoven, 5600 MB Eindhoven, Netherlands
| | - Jurjen Tel
- Laboratory of Immunoengineering, Department of Biomedical Engineering, TU Eindhoven, 5600 MB Eindhoven, Netherlands
- Institute of Complex Molecular Systems, TU Eindhoven, 5600 MB Eindhoven, Netherlands
| |
Collapse
|
9
|
Sateesh J, Guha K, Dutta A, Sengupta P, Yalamanchili D, Donepudi NS, Surya Manoj M, Sohail SS. A comprehensive review on advancements in tissue engineering and microfluidics toward kidney-on-chip. BIOMICROFLUIDICS 2022; 16:041501. [PMID: 35992641 PMCID: PMC9385224 DOI: 10.1063/5.0087852] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Accepted: 07/19/2022] [Indexed: 06/15/2023]
Abstract
This review provides a detailed literature survey on microfluidics and its road map toward kidney-on-chip technology. The whole review has been tailored with a clear description of crucial milestones in regenerative medicine, such as bioengineering, tissue engineering, microfluidics, microfluidic applications in biomedical engineering, capabilities of microfluidics in biomimetics, organ-on-chip, kidney-on-chip for disease modeling, drug toxicity, and implantable devices. This paper also presents future scope for research in the bio-microfluidics domain and biomimetics domain.
Collapse
Affiliation(s)
| | - Koushik Guha
- Department of Electronics and Communication Engineering, National MEMS Design Centre, National Institute of Technology Silchar, Assam 788010, India
| | - Arindam Dutta
- Urologist, RG Stone Urology and Laparoscopic Hospital, Kolkata, West Bengal, India
| | | | | | - Nanda Sai Donepudi
- Medical Interns, Government Siddhartha Medical College, Vijayawada, India
| | - M. Surya Manoj
- Department of Electronics and Communication Engineering, National MEMS Design Centre, National Institute of Technology Silchar, Assam 788010, India
| | - Sk. Shahrukh Sohail
- Department of Electronics and Communication Engineering, National MEMS Design Centre, National Institute of Technology Silchar, Assam 788010, India
| |
Collapse
|
10
|
Li N, Zhang Y, Shen M, Xu Y. A fully integrated SNP genotyping system for hereditary hearing-loss detection. LAB ON A CHIP 2022; 22:697-708. [PMID: 34923580 DOI: 10.1039/d1lc00805f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Hereditary hearing loss is one of the most common human neurosensory disorders, and there is a great need for early intervention methods such as genetically screening newborns. Single nucleotide polymorphisms (SNPs) are the major genetic targets for hearing-loss screening. In this study, a fully integrated SNP genotyping system was constructed to identify hereditary hearing loss-related genetic markers from human whole blood. The entire detection process, including blood cell lysis, nucleic acid extraction, the reaction mixture distribution, the chambers sealing and the two-colour multiplex competitive allele-specific polymerase chain reaction (KASP), can be automatically conducted in a self-contained cassette within 3 hours. To critically evaluate the performance of the system, its specificity, sensitivity and stability were assessed. Then, 13 clinical samples were genotyped with this fluidic cassette system to detect seven hotspot deafness-associated mutations in three genes (MT-RNR1, GJB2 and SLC26A4). The detection results of the cassette system were 100% concordant with those obtained by Sanger sequencing, proving its accuracy in the genetic screening of inherited hearing loss.
Collapse
Affiliation(s)
- Nan Li
- State Key Laboratory of Membrane Biology, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
| | - Yuanyue Zhang
- State Key Laboratory of Membrane Biology, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
| | - Minjie Shen
- State Key Laboratory of Membrane Biology, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
| | - Youchun Xu
- State Key Laboratory of Membrane Biology, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
11
|
Eills J, Hale W, Utz M. Synergies between Hyperpolarized NMR and Microfluidics: A Review. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2022; 128:44-69. [PMID: 35282869 DOI: 10.1016/j.pnmrs.2021.09.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 09/10/2021] [Accepted: 09/11/2021] [Indexed: 06/14/2023]
Abstract
Hyperpolarized nuclear magnetic resonance and lab-on-a-chip microfluidics are two dynamic, but until recently quite distinct, fields of research. Recent developments in both areas increased their synergistic overlap. By microfluidic integration, many complex experimental steps can be brought together onto a single platform. Microfluidic devices are therefore increasingly finding applications in medical diagnostics, forensic analysis, and biomedical research. In particular, they provide novel and powerful ways to culture cells, cell aggregates, and even functional models of entire organs. Nuclear magnetic resonance is a non-invasive, high-resolution spectroscopic technique which allows real-time process monitoring with chemical specificity. It is ideally suited for observing metabolic and other biological and chemical processes in microfluidic systems. However, its intrinsically low sensitivity has limited its application. Recent advances in nuclear hyperpolarization techniques may change this: under special circumstances, it is possible to enhance NMR signals by up to 5 orders of magnitude, which dramatically extends the utility of NMR in the context of microfluidic systems. Hyperpolarization requires complex chemical and/or physical manipulations, which in turn may benefit from microfluidic implementation. In fact, many hyperpolarization methodologies rely on processes that are more efficient at the micro-scale, such as molecular diffusion, penetration of electromagnetic radiation into a sample, or restricted molecular mobility on a surface. In this review we examine the confluence between the fields of hyperpolarization-enhanced NMR and microfluidics, and assess how these areas of research have mutually benefited one another, and will continue to do so.
Collapse
Affiliation(s)
- James Eills
- Institute for Physics, Johannes Gutenberg University, D-55090 Mainz, Germany; GSI Helmholtzzentrum für Schwerionenforschung GmbH, Helmholtz-Institut Mainz, 55128 Mainz, Germany.
| | - William Hale
- Department of Chemistry, University of Florida, 32611, USA
| | - Marcel Utz
- School of Chemistry, University of Southampton, SO17 1BJ, UK.
| |
Collapse
|
12
|
Duarte LC, Pereira I, Maciel LIL, Vaz BG, Coltro WKT. 3D printed microfluidic mixer for real-time monitoring of organic reactions by direct infusion mass spectrometry. Anal Chim Acta 2022; 1190:339252. [PMID: 34857139 DOI: 10.1016/j.aca.2021.339252] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 08/31/2021] [Accepted: 11/03/2021] [Indexed: 12/26/2022]
Abstract
3D printing is a technology that has revolutionized traditional rapid prototyping methods due to its ability to build microscale structures with customized geometries in a simple, fast, and low-cost way. In this sense, this article describes the development of a microfluidic mixing device to monitor chemical reactions by mass spectrometry (MS). Microfluidic mixers were designed containing 3D serpentine and Y-shaped microchannels, both with a pointed end for facilitating the spray formation. The devices were fabricated entirely by 3D printing with fusion deposition modeling (FDM) technology. As proof-of-concept, micromixers were evaluated through monitoring the Katritzky reaction by injecting simultaneously 2,4,6-triphenylpropyllium (TPP) and amino acid (glycine or alanine) solutions, each through a different reactor inlet. Reaction product was monitored online by MS at different flow rates. Mass spectra showed that the relative abundances of the products obtained with the device containing the 3D serpentine channel were three times greater than those obtained with the Y-channel device due to the turbulence generated by the barriers created inside microchannels. In addition, when compared to the conventional electrospray ionization mass spectrometry (ESI-MS) technique, the 3D serpentine mixer offered better performance measured in relation to the relative abundance values for the reaction products. These results as well as the instrumental simplicity indicate that 3D printed microfluidic mixer is a promising tool for monitoring organic reactions via MS.
Collapse
Affiliation(s)
- Lucas C Duarte
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Igor Pereira
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Lanaia I L Maciel
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Boniek G Vaz
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica, 13084-971, Campinas, SP, Brazil.
| |
Collapse
|
13
|
Guduru SSK, Bucella SG, Bonfadini S, Vishnubhatla KC, Caironi M, Criante L. Semi-transparent 3D microelectrodes buried in fused silica for photonics applications. OPTICS EXPRESS 2021; 29:27149-27159. [PMID: 34615136 DOI: 10.1364/oe.433330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 07/13/2021] [Indexed: 06/13/2023]
Abstract
We report the realization of semi-transparent 3D microelectrodes fully embedded in a fused silica substrate by a combination of femtosecond laser microfabrication and inkjet printing. We also demonstrate the application of such electrodes in a proof-of-concept lab-on-chip device configuration, which acts as a liquid crystal molecular polarization rotator using on-chip electric fields. This work constitutes a first of its kind synergy between two widely used microfabrication techniques, femtosecond laser and inkjet, demonstrating a very efficient integration of optical, electrical and microfluidic components in a unique platform and thus enabling fast prototyping of 3D structured electro-optic lab-on-chips.
Collapse
|
14
|
Guttenplan APM, Tahmasebi Birgani Z, Giselbrecht S, Truckenmüller RK, Habibović P. Chips for Biomaterials and Biomaterials for Chips: Recent Advances at the Interface between Microfabrication and Biomaterials Research. Adv Healthc Mater 2021; 10:e2100371. [PMID: 34033239 DOI: 10.1002/adhm.202100371] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 05/08/2021] [Indexed: 12/24/2022]
Abstract
In recent years, the use of microfabrication techniques has allowed biomaterials studies which were originally carried out at larger length scales to be miniaturized as so-called "on-chip" experiments. These miniaturized experiments have a range of advantages which have led to an increase in their popularity. A range of biomaterial shapes and compositions are synthesized or manufactured on chip. Moreover, chips are developed to investigate specific aspects of interactions between biomaterials and biological systems. Finally, biomaterials are used in microfabricated devices to replicate the physiological microenvironment in studies using so-called "organ-on-chip," "tissue-on-chip" or "disease-on-chip" models, which can reduce the use of animal models with their inherent high cost and ethical issues, and due to the possible use of human cells can increase the translation of research from lab to clinic. This review gives an overview of recent developments at the interface between microfabrication and biomaterials science, and indicates potential future directions that the field may take. In particular, a trend toward increased scale and automation is apparent, allowing both industrial production of micron-scale biomaterials and high-throughput screening of the interaction of diverse materials libraries with cells and bioengineered tissues and organs.
Collapse
Affiliation(s)
- Alexander P. M. Guttenplan
- Department of Instructive Biomaterials Engineering MERLN Institute for Technology‐Inspired Regenerative Medicine Maastricht University Universiteitssingel 40 Maastricht 6229ER The Netherlands
| | - Zeinab Tahmasebi Birgani
- Department of Instructive Biomaterials Engineering MERLN Institute for Technology‐Inspired Regenerative Medicine Maastricht University Universiteitssingel 40 Maastricht 6229ER The Netherlands
| | - Stefan Giselbrecht
- Department of Instructive Biomaterials Engineering MERLN Institute for Technology‐Inspired Regenerative Medicine Maastricht University Universiteitssingel 40 Maastricht 6229ER The Netherlands
| | - Roman K. Truckenmüller
- Department of Instructive Biomaterials Engineering MERLN Institute for Technology‐Inspired Regenerative Medicine Maastricht University Universiteitssingel 40 Maastricht 6229ER The Netherlands
| | - Pamela Habibović
- Department of Instructive Biomaterials Engineering MERLN Institute for Technology‐Inspired Regenerative Medicine Maastricht University Universiteitssingel 40 Maastricht 6229ER The Netherlands
| |
Collapse
|
15
|
Chung YD, Liu TH, Liang YL, Lin CN, Hsu KF, Lee GB. An integrated microfluidic platform for detection of ovarian clear cell carcinoma mRNA biomarker FXYD2. LAB ON A CHIP 2021; 21:2625-2632. [PMID: 34013940 DOI: 10.1039/d1lc00177a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
In this work we developed an integrated microfluidic system for automatically detecting the ovarian clear cell carcinoma (OCCC) biomarker FXYD2. Dealing with ascites from ovarian cancer patients, capture of cancer cells, isolation of messenger RNA, and quantitative reverse-transcription polymerase chain reaction were integrated into a single microfluidic chip and carried out on-chip automatically. OCCC is a subtype of ovarian cancer with a high mortality risk, and a high FXYD2 gene expression level was shown to be closely associated with OCCC. The lowest limit of quantification using a benchtop protocol of this system could be as low as 100 copies per sample. By normalizing the expression to a housekeeping gene, GAPDH, a simple cycle threshold ratio index could distinguish high FXYD2 expression cells from the low-expression ones. This developed platform may therefore facilitate future OCCC diagnosis and/or prognosis.
Collapse
Affiliation(s)
- Yi-Da Chung
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan.
| | - Ting-Hang Liu
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan.
| | - Yu-Ling Liang
- Department of Obstetrics and Gynecology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 70403, Taiwan.
| | - Chang-Ni Lin
- Department of Obstetrics and Gynecology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 70403, Taiwan.
| | - Keng-Fu Hsu
- Department of Obstetrics and Gynecology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 70403, Taiwan.
| | - Gwo-Bin Lee
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan. and Institute of NanoEngineering and MicroSystems, National Tsing Hua University, Hsinchu, Taiwan and Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu, Taiwan
| |
Collapse
|
16
|
An innovative and user-friendly smartphone-assisted molecular diagnostic approach for rapid detection of canine vector-borne diseases. Parasitol Res 2021; 120:1799-1809. [PMID: 33649963 PMCID: PMC7920752 DOI: 10.1007/s00436-021-07077-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 02/01/2021] [Indexed: 11/17/2022]
Abstract
Present-day diagnostic tools and technologies for canine diseases and other vector-borne parasitic diseases hardly meet the requirements of an efficient and rapid diagnostic tool, which can be suitable for use at the point-of-care in resource-limited settings. Loop-mediated isothermal amplification (LAMP) technique has been always a method of choice in the development and validation of quick, precise, and sensitive diagnostic assays for pathogen detection and to reorganize point-of-care (POC) molecular diagnostics. In this study, we have demonstrated an efficient detection system for parasitic vector-borne pathogens like Ehrlichia canis and Hepatozoon canis by linking the LAMP assay to a smartphone via a simple, inexpensive, and a portable “LAMP box,” All the components of the LAMP box were connected to each other wirelessly. This LAMP box was made up of an isothermal heating pad mounted below an aluminum base which served as a platform for the reaction tubes and LAMP assay. The entire setup could be connected to a smartphone via an inbuilt Wi-Fi that allowed the user to establish the connection to control the LAMP box. A 5 V USB power source was used as a power supply. The sensitivity of the LAMP assay was estimated to be up to 10−6 dilution limit using the amplified, purified, and quantified specific DNA templates. It can also serve as an efficient diagnostic platform for many other veterinary infectious or parasitic diseases of zoonotic origin majorly towards field-based diagnostics.
Collapse
|
17
|
Wang K, He L, Manz A, Wu W. User-Friendly Microfabrication Method for Complex Topological Structure and Three-Dimensional Microchannel with the Application Prospect in Polymerase Chain Reaction (PCR). Anal Chem 2021; 93:1523-1528. [PMID: 33326206 DOI: 10.1021/acs.analchem.0c03827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
One of the most important challenges in the field of microfluidics is the rapid fabrication of microchips with complex topologies. Although the processing method of microfluidic chips has made brilliant achievements in the past 20 years, almost all traditional processing methods still face huge obstacles in the production of complex topologies and three-dimensional microchannel. Nowadays, the main methods of manufacturing microfluidic chips such as numerical control microprocessing, laser ablation, inkjet printing, photolithography, dry etching, and lithography, galvanoformung and abformung (LIGA) technology are not only inapplicable to the complex topological structure and the rapid processing of three-dimensional microfluidic chips but also rely on expensive processing equipment, complex manufacturing process, and low yield. To solve the problems of these traditional processing methods, we propose a low-cost methodology to obtain a microfluidic chip by sewing the chip pipe to the substrate with an embroidery machine as low as $6. Compared with the above-mentioned traditional microprocessing technologies, the new chip processing technology proposed by us does not involve professional microprocessing equipment and professional skills. Therefore, this new chip processing technology can significantly improve the efficiency of microprocessing.
Collapse
Affiliation(s)
- Kangning Wang
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China
| | - Limin He
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China.,University of Chinese Academy of Sciences (UCAS), Beijing 100049, China
| | - Andreas Manz
- Systems Engineering Department, Saarland University, 66123 Saarbrücken, Germany.,Bio Sensor & Materials Group, KIST Europe, 66123 Saarbrücken, Germany
| | - Wenming Wu
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China
| |
Collapse
|
18
|
Tarim EA, Karakuzu B, Oksuz C, Sarigil O, Kizilkaya M, Al-Ruweidi MKAA, Yalcin HC, Ozcivici E, Tekin HC. Microfluidic-based virus detection methods for respiratory diseases. EMERGENT MATERIALS 2021; 4:143-168. [PMID: 33786415 PMCID: PMC7992628 DOI: 10.1007/s42247-021-00169-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Accepted: 01/19/2021] [Indexed: 05/04/2023]
Abstract
With the recent SARS-CoV-2 outbreak, the importance of rapid and direct detection of respiratory disease viruses has been well recognized. The detection of these viruses with novel technologies is vital in timely prevention and treatment strategies for epidemics and pandemics. Respiratory viruses can be detected from saliva, swab samples, nasal fluid, and blood, and collected samples can be analyzed by various techniques. Conventional methods for virus detection are based on techniques relying on cell culture, antigen-antibody interactions, and nucleic acids. However, these methods require trained personnel as well as expensive equipment. Microfluidic technologies, on the other hand, are one of the most accurate and specific methods to directly detect respiratory tract viruses. During viral infections, the production of detectable amounts of relevant antibodies takes a few days to weeks, hampering the aim of prevention. Alternatively, nucleic acid-based methods can directly detect the virus-specific RNA or DNA region, even before the immune response. There are numerous methods to detect respiratory viruses, but direct detection techniques have higher specificity and sensitivity than other techniques. This review aims to summarize the methods and technologies developed for microfluidic-based direct detection of viruses that cause respiratory infection using different detection techniques. Microfluidics enables the use of minimal sample volumes and thereby leading to a time, cost, and labor effective operation. Microfluidic-based detection technologies provide affordable, portable, rapid, and sensitive analysis of intact virus or virus genetic material, which is very important in pandemic and epidemic events to control outbreaks with an effective diagnosis.
Collapse
Affiliation(s)
- E. Alperay Tarim
- Department of Bioengineering, Izmir Institute of Technology, Urla, Izmir, Turkey
| | - Betul Karakuzu
- Department of Bioengineering, Izmir Institute of Technology, Urla, Izmir, Turkey
| | - Cemre Oksuz
- Department of Bioengineering, Izmir Institute of Technology, Urla, Izmir, Turkey
| | - Oyku Sarigil
- Department of Bioengineering, Izmir Institute of Technology, Urla, Izmir, Turkey
| | - Melike Kizilkaya
- Department of Bioengineering, Izmir Institute of Technology, Urla, Izmir, Turkey
| | | | | | - Engin Ozcivici
- Department of Bioengineering, Izmir Institute of Technology, Urla, Izmir, Turkey
| | - H. Cumhur Tekin
- Department of Bioengineering, Izmir Institute of Technology, Urla, Izmir, Turkey
- METU MEMS Center, Ankara, Turkey
| |
Collapse
|
19
|
Çağlayan Z, Demircan Yalçın Y, Külah H. A Prominent Cell Manipulation Technique in BioMEMS: Dielectrophoresis. MICROMACHINES 2020; 11:E990. [PMID: 33153069 PMCID: PMC7693018 DOI: 10.3390/mi11110990] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 10/22/2020] [Accepted: 10/28/2020] [Indexed: 12/17/2022]
Abstract
BioMEMS, the biological and biomedical applications of micro-electro-mechanical systems (MEMS), has attracted considerable attention in recent years and has found widespread applications in disease detection, advanced diagnosis, therapy, drug delivery, implantable devices, and tissue engineering. One of the most essential and leading goals of the BioMEMS and biosensor technologies is to develop point-of-care (POC) testing systems to perform rapid prognostic or diagnostic tests at a patient site with high accuracy. Manipulation of particles in the analyte of interest is a vital task for POC and biosensor platforms. Dielectrophoresis (DEP), the induced movement of particles in a non-uniform electrical field due to polarization effects, is an accurate, fast, low-cost, and marker-free manipulation technique. It has been indicated as a promising method to characterize, isolate, transport, and trap various particles. The aim of this review is to provide fundamental theory and principles of DEP technique, to explain its importance for the BioMEMS and biosensor fields with detailed references to readers, and to identify and exemplify the application areas in biosensors and POC devices. Finally, the challenges faced in DEP-based systems and the future prospects are discussed.
Collapse
Affiliation(s)
- Zeynep Çağlayan
- Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara 06800, Turkey; (Z.Ç.); (Y.D.Y.)
- METU MEMS Research and Application Center, Ankara 06800, Turkey
| | - Yağmur Demircan Yalçın
- Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara 06800, Turkey; (Z.Ç.); (Y.D.Y.)
- Mikro Biyosistemler Electronics Inc., Ankara 06530, Turkey
| | - Haluk Külah
- Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara 06800, Turkey; (Z.Ç.); (Y.D.Y.)
- METU MEMS Research and Application Center, Ankara 06800, Turkey
- Mikro Biyosistemler Electronics Inc., Ankara 06530, Turkey
| |
Collapse
|
20
|
Khan JU, Sayyar S, Paull B, Innis PC. Novel Approach toward Electrofluidic Substrates Utilizing Textile-Based Braided Structure. ACS APPLIED MATERIALS & INTERFACES 2020; 12:45618-45628. [PMID: 32910632 DOI: 10.1021/acsami.0c13740] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Electrofluidics is the unique combination of electrophoresis and microfluidics, which has opened up broad opportunities for bioanalysis and multiplexed assay. These systems typically comprise inaccessible and fully enclosed microcapillary or microchannels, with limited sample loading capacities and no direct access to the solutes within. Here, we investigate the application of multiyarn textile assemblies which provides an open and surface accessible electrophoretic separation platform. Three-dimensional (3D) textile structures have been produced using conventional knitting and braiding techniques from a range of commercially available yarns. Capillary zone electrophoresis separation studies have been carried out on these substrates using fluorescent anionic (fluorescence, FL) and cationic (rhodamine-B, Rh-B) markers. The effects of different yarn surface chemistry, textile fabrication technique, and electrolyte ionic strength on the electrophoretic mobility of the test analytes have been studied. From the broad range of yarns investigated, polyester was shown to have the highest electrophoretic mobility for Rh-B (6 × 10-4 cm2 V-1 s-1) and for FL (4 × 10-4 cm2 V-1 s-1). The braiding approach, being simple and versatile, was found to be the most effective route to produce 3D textile-based structures and offered the potential for selective movement and targeted delivery to different channels. Composite braids made with yarns of differential surface chemistries further revealed a unique behavior of separation and parallel movement of oppositely charged ionic species. We also demonstrate the feasibility to apply isotachophoresis (ITP) on these braided textile substrates to rapidly focus dispersed FL sample bands. Here, we demonstrate the focusing of FL from a dispersed band into narrow band with a 400 times reduction in sample width over 90 s. Owing to the simplicity and reproducibility of the developed approach, textile-based inverted microfluidic applications are expected to enable opportunities in bioanalysis, proteomics, and rapid clinical diagnostics.
Collapse
Affiliation(s)
- Jawairia Umar Khan
- ARC Centre of Excellence for Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, Wollongong, New South Wales 2500, Australia
- Department of Fibre and Textile Technology, University of Agriculture, Faisalabad 38000, Pakistan
| | - Sepidar Sayyar
- ARC Centre of Excellence for Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, Wollongong, New South Wales 2500, Australia
- Australian National Fabrication Facility-Materials Node, Innovation Campus, University of Wollongong, Wollongong, New South Wales 2500, Australia
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS) and ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7005, Australia
| | - Peter C Innis
- ARC Centre of Excellence for Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, Wollongong, New South Wales 2500, Australia
- Australian National Fabrication Facility-Materials Node, Innovation Campus, University of Wollongong, Wollongong, New South Wales 2500, Australia
| |
Collapse
|
21
|
Yafia M, Foudeh AM, Tabrizian M, Najjaran H. Low-Cost Graphene-Based Digital Microfluidic System. MICROMACHINES 2020; 11:mi11090880. [PMID: 32971896 PMCID: PMC7569958 DOI: 10.3390/mi11090880] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 09/13/2020] [Accepted: 09/16/2020] [Indexed: 01/15/2023]
Abstract
In this work, the laser-scribing technique was used as a low-cost, rapid and facile method for fabricating digital microfluidic (DMF) systems. Laser-scribed graphene (LSG) electrodes are directly synthesized on flexible substrates to pattern the DMF electrode arrays. This facilitates the DMF electrodes’ fabrication process by eliminating many microfabrication steps. An electrowetting test was performed to investigate the effectiveness of the LSG DMF electrodes in changing the contact angles of droplets. Different DMF operations were successfully performed using the proposed LSG DMF chips in both open and closed DMF systems. The quality and output resolution were examined to assess the performance of such patterned electrodes in the DMF systems. To verify the efficacy of the LSG DMF chips, a one-step direct assay for the detection of Legionellapneumophila deoxyribonucleic acid (DNA) was performed on the chip without the need for any washing step. The high specificity in distinguishing a single-nucleotide mismatch was achieved by detecting target DNA concentrations as low as 1 nM. Our findings suggest that the proposed rapid and easy fabrication method for LSG DMF electrodes offers a great platform for low-cost and easily accessible point-of-care diagnostic devices.
Collapse
Affiliation(s)
- Mohamed Yafia
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada
- Correspondence: (M.Y.); (H.N.)
| | - Amir M. Foudeh
- Department of Biomedical Engineering, Faculty of Medicine, McGill University, Montreal, QC H3A 0C7, Canada; (A.M.F.); (M.T.)
| | - Maryam Tabrizian
- Department of Biomedical Engineering, Faculty of Medicine, McGill University, Montreal, QC H3A 0C7, Canada; (A.M.F.); (M.T.)
- Faculty of Dentistry, McGill University, Montreal, QC H3A 1G1, Canada
| | - Homayoun Najjaran
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada
- Correspondence: (M.Y.); (H.N.)
| |
Collapse
|
22
|
Zhuang J, Yin J, Lv S, Wang B, Mu Y. Advanced "lab-on-a-chip" to detect viruses - Current challenges and future perspectives. Biosens Bioelectron 2020; 163:112291. [PMID: 32421630 PMCID: PMC7215165 DOI: 10.1016/j.bios.2020.112291] [Citation(s) in RCA: 82] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 05/02/2020] [Accepted: 05/10/2020] [Indexed: 12/28/2022]
Abstract
Massive viral outbreaks draw attention to viruses that have not been thoroughly studied or understood. In recent decades, microfluidic chips, known as "lab-on-a-chip", appears as a promising tool for the detection of viruses. Here, we review the development of microfluidic chips that could be used in response to viral detection, specifically for viruses involved in more recent outbreaks. The advantages as well as the disadvantages of microfluidic systems are discussed and analyzed. We also propose ideas for future development of these microfluidic chips and we expect this advanced technology to be used in the future for viral outbreaks.
Collapse
Affiliation(s)
- Jianjian Zhuang
- College of Life Sciences, Zhejiang University, Hangzhou, 310058, Zhejiang, China
| | - Juxin Yin
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou, Zhejiang Province, 310058, China; Cancer Institute (Key Laboratory of Cancer Prevention and Intervention, National Ministry of Education), The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310009, China; Institute of Translational Medicine, Zhejiang University, Hangzhou, 310029, China
| | - Shaowu Lv
- Key Laboratory for Molecular Enzymology and Engineering of the Ministry of Education, College of Life Science, Jilin University, Changchun, 130000, China
| | - Ben Wang
- Cancer Institute (Key Laboratory of Cancer Prevention and Intervention, National Ministry of Education), The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310009, China; Institute of Translational Medicine, Zhejiang University, Hangzhou, 310029, China
| | - Ying Mu
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou, Zhejiang Province, 310058, China; College of Life Sciences, Zhejiang University, Hangzhou, 310058, Zhejiang, China.
| |
Collapse
|
23
|
Kanitthamniyom P, Zhou A, Feng S, Liu A, Vasoo S, Zhang Y. A 3D-printed modular magnetic digital microfluidic architecture for on-demand bioanalysis. MICROSYSTEMS & NANOENGINEERING 2020; 6:48. [PMID: 34567660 PMCID: PMC8433373 DOI: 10.1038/s41378-020-0152-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 01/22/2020] [Accepted: 02/29/2020] [Indexed: 05/04/2023]
Abstract
Magnetic digital microfluidics (MDM) manipulates fluids in the form of droplets on an open substrate, and incorporates surface energy traps (SETs) to facilitate the droplet manipulation. Conventional MDM devices are fabricated monolithically, which makes it difficult to modify the device configuration without completely overhauling the original design. In this paper, we present a modular MDM architecture that enables rapid on-demand configuration and re-configuration of MDM platforms for customized bioanalyses. Each modular component contains a SET and a Lego-like antistud that fits onto a base board with Lego-like studs. We illustrate the versatility of the modular MDM architecture in biomarker sensing, pathogen identification, antibiotic resistance determination, and biochemical quantification by demonstrating immunoassays, phenotypical assays and enzymatic assays on various modular MDM platforms configured on demand to accomplish the fluidic operations required by assorted bioanalytical assays. The modular MDM architecture promises great potential for point-of-care diagnostics by offering on-demand customization of testing platforms for various categories of diagnostic assays. It also provides a new avenue for microfluidic assay development with its high configurability which would significantly reduce the time and cost of the development cycle.
Collapse
Affiliation(s)
- Pojchanun Kanitthamniyom
- Singapore Centre for 3D Printing, School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
| | - Aiwu Zhou
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
| | - Shilun Feng
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore, Singapore
| | - Aiqun Liu
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore, Singapore
| | - Shawn Vasoo
- National Center for Infectious Disease, Tan Tock Seng Hospital, Singapore, Singapore
| | - Yi Zhang
- Singapore Centre for 3D Printing, School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
| |
Collapse
|
24
|
Singh J, Mehta A. Rapid and sensitive detection of mycotoxins by advanced and emerging analytical methods: A review. Food Sci Nutr 2020; 8:2183-2204. [PMID: 32405376 PMCID: PMC7215233 DOI: 10.1002/fsn3.1474] [Citation(s) in RCA: 81] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2019] [Revised: 01/20/2020] [Accepted: 01/22/2020] [Indexed: 01/24/2023] Open
Abstract
Quantification of mycotoxins in foodstuffs is extremely difficult as a limited amount of toxins are known to be presented in the food samples. Mycotoxins are secondary toxic metabolites, made primarily by fungal species, contaminating feeds and foods. Due to the presence in globally used grains, it is an unpreventable problem that causes various acute and chronic impacts on human and animal health. Over the previous few years, however, progress has been made in mycotoxin analysis studies. Easier techniques of sample cleanup and advanced chromatographic approaches have been developed, primarily high-performance liquid chromatography. Few extremely sophisticated and adaptable tools such as high-resolution mass spectrometry and gas chromatography-tandem MS/MS have become more important. In addition, Immunoassay, Advanced quantitative techniques are now globally accepted for mycotoxin analysis. Thus, this review summarizes these traditional and highly advance methods and their characteristics for evaluating mycotoxins.
Collapse
Affiliation(s)
- Jyoti Singh
- Department of Integrative BiologySchool of Biosciences and TechnologyVellore Institute of TechnologyVelloreIndia
| | - Alka Mehta
- Department of Integrative BiologySchool of Biosciences and TechnologyVellore Institute of TechnologyVelloreIndia
| |
Collapse
|
25
|
Low-cost Point-of-Care Biosensors Using Common Electronic Components as Transducers. BIOCHIP JOURNAL 2020. [DOI: 10.1007/s13206-020-4104-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
26
|
Guerrero J, Chang YW, Fragkopoulos AA, Fernandez-Nieves A. Capillary-Based Microfluidics-Coflow, Flow-Focusing, Electro-Coflow, Drops, Jets, and Instabilities. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e1904344. [PMID: 31663270 DOI: 10.1002/smll.201904344] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Revised: 09/13/2019] [Indexed: 06/10/2023]
Abstract
Capillary-based microfluidics is a great technique to produce monodisperse and complex emulsions and particulate suspensions. In this review, the current understanding of drop and jet formation in capillary-based microfluidic devices for two primary flow configurations, coflow and flow-focusing is summarized. The experimental and theoretical description of fluid instabilities is discussed and conditions for controlled drop breakup in different modes of drop generation are provided. Current challenges in drop breakup with low interfacial tension systems and recent progress in overcoming drop size limitations using electro-coflow are addressed. In each scenario, the physical mechanisms for drop breakup are revisited, and simple scaling arguments proposed in the literature are introduced.
Collapse
Affiliation(s)
- Josefa Guerrero
- Department of Chemistry and Physics, Augusta University, Augusta, GA, 30912, USA
| | - Ya-Wen Chang
- Department of Chemical Engineering, Texas Tech University, Lubbock, TX, 79409, USA
| | - Alexandros A Fragkopoulos
- Department of Dynamics of Complex Fluids, Max Planck Institute for Dynamics and Self-Organization, 37077, Göttingen, Germany
| | - Alberto Fernandez-Nieves
- School of Physics, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- Department of Condensed Matter Physics, University of Barcelona, 08028, Barcelona, Spain
- ICREA-Institució Caalana de Recerca i Estudis Avançats, 08010, Barcelona, Spain
| |
Collapse
|
27
|
On-chip integration of normal phase high-performance liquid chromatography and droplet microfluidics introducing ethylene glycol as polar continuous phase for the compartmentalization of n-heptane eluents. J Chromatogr A 2020; 1612:460653. [DOI: 10.1016/j.chroma.2019.460653] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Revised: 10/08/2019] [Accepted: 10/23/2019] [Indexed: 01/06/2023]
|
28
|
De Risi C, Bortolini O, Brandolese A, Di Carmine G, Ragno D, Massi A. Recent advances in continuous-flow organocatalysis for process intensification. REACT CHEM ENG 2020. [DOI: 10.1039/d0re00076k] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
The progresses on continuous-flow organocatalysis from 2016 to early 2020 are reviewed with focus on transition from batch to flow.
Collapse
Affiliation(s)
- Carmela De Risi
- Dipartimento di Scienze Chimiche e Farmaceutiche
- I-44121 Ferrara
- Italy
| | - Olga Bortolini
- Dipartimento di Scienze Chimiche e Farmaceutiche
- I-44121 Ferrara
- Italy
| | | | | | - Daniele Ragno
- Dipartimento di Scienze Chimiche e Farmaceutiche
- I-44121 Ferrara
- Italy
| | - Alessandro Massi
- Dipartimento di Scienze Chimiche e Farmaceutiche
- I-44121 Ferrara
- Italy
| |
Collapse
|
29
|
Kubota R, Sasaki Y, Minamiki T, Minami T. Chemical Sensing Platforms Based on Organic Thin-Film Transistors Functionalized with Artificial Receptors. ACS Sens 2019; 4:2571-2587. [PMID: 31475522 DOI: 10.1021/acssensors.9b01114] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Organic thin-film transistors (OTFTs) have attracted intense attention as promising electronic devices owing to their various applications such as rollable active-matrix displays, flexible nonvolatile memories, and radiofrequency identification (RFID) tags. To further broaden the scope of the application of OTFTs, we focus on the host-guest chemistry combined with the electronic devices. Extended-gate types of OTFTs functionalized with artificial receptors were fabricated to achieve chemical sensing of targets in complete aqueous media. Organic and inorganic ions (cations and anions), neutral molecules, and proteins, which are regarded as target analytes in the field of host-guest chemistry, were electrically detected by artificial receptors. Molecular recognition phenomena on the extended-gate electrode were evaluated by several analytical methods such as photoemission yield spectroscopy in the air, contact angle goniometry, and X-ray photoelectron spectroscopy. Interestingly, the electrical responses of the OTFTs were highly sensitive to the chemical structures of the guests. Thus, the OTFTs will facilitate the selective sensing of target analytes and the understanding of chemical conversions in biological and environmental systems. Furthermore, such cross-reactive responses observed in our studies will provide some important insights into next-generation sensing systems such as OTFT arrays. We strongly believe that our approach will enable the development of new intriguing sensor platforms in the field of host-guest chemistry, analytical chemistry, and organic electronics.
Collapse
Affiliation(s)
- Riku Kubota
- Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153−8505, Japan
| | - Yui Sasaki
- Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153−8505, Japan
| | - Tsukuru Minamiki
- Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153−8505, Japan
| | - Tsuyoshi Minami
- Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153−8505, Japan
| |
Collapse
|
30
|
Cooksey GA, Patrone PN, Hands JR, Meek SE, Kearsley AJ. Dynamic Measurement of Nanoflows: Realization of an Optofluidic Flow Meter to the Nanoliter-per-Minute Scale. Anal Chem 2019; 91:10713-10722. [DOI: 10.1021/acs.analchem.9b02056] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Affiliation(s)
| | | | | | - Stephen E. Meek
- Biotechnology Program, Montgomery College, Germantown, Maryland 20876, United States
| | | |
Collapse
|
31
|
Piendl SK, Raddatz CR, Hartner NT, Thoben C, Warias R, Zimmermann S, Belder D. 2D in Seconds: Coupling of Chip-HPLC with Ion Mobility Spectrometry. Anal Chem 2019; 91:7613-7620. [DOI: 10.1021/acs.analchem.9b00302] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Sebastian K. Piendl
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Christian-Robert Raddatz
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Nora T. Hartner
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Christian Thoben
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Rico Warias
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Stefan Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Detlev Belder
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| |
Collapse
|
32
|
Saar KL, Peter Q, Müller T, Challa PK, Herling TW, Knowles TPJ. Rapid two-dimensional characterisation of proteins in solution. MICROSYSTEMS & NANOENGINEERING 2019; 5:33. [PMID: 31636924 PMCID: PMC6799820 DOI: 10.1038/s41378-019-0072-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Revised: 02/25/2019] [Accepted: 03/21/2019] [Indexed: 05/20/2023]
Abstract
Microfluidic platforms provide an excellent basis for working with heterogeneous samples and separating biomolecular components at high throughput, with high recovery rates and by using only very small sample volumes. To date, several micron scale platforms with preparative capabilities have been demonstrated. Here we describe and demonstrate a microfluidic device that brings preparative and analytical operations together onto a single chip and thereby allows the acquisition of multidimensional information. We achieve this objective by using a free-flow electrophoretic separation approach that directs fractions of sample into an on-chip analysis unit, where the fractions are characterised through a microfluidic diffusional sizing process. This combined approach therefore allows simultaneously quantifying the sizes and the charges of components in heterogenous mixtures. We illustrate the power of the platform by describing the size distribution of a mixture comprising components which are close in size and cannot be identified as individual components using state-of-the-art solution sizing techniques on their own. Furthermore, we show that the platform can be used for two-dimensional fingerprinting of heterogeneous protein mixtures within tens of seconds, opening up a possibility to obtain multiparameter data on biomolecular systems on a minute timescale.
Collapse
Affiliation(s)
- Kadi L. Saar
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW UK
| | - Quentin Peter
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW UK
- Cavendish Laboratory, Department of Physics, University of Cambridge, J J Thomson Ave, Cambridge, CB3 0HE UK
| | | | - Pavan K. Challa
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW UK
- Cavendish Laboratory, Department of Physics, University of Cambridge, J J Thomson Ave, Cambridge, CB3 0HE UK
| | - Therese W. Herling
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW UK
| | - Tuomas P. J. Knowles
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW UK
- Cavendish Laboratory, Department of Physics, University of Cambridge, J J Thomson Ave, Cambridge, CB3 0HE UK
| |
Collapse
|
33
|
Yin J, Hu J, Sun J, Wang B, Mu Y. A fast nucleic acid extraction system for point-of-care and integration of digital PCR. Analyst 2019; 144:7032-7040. [DOI: 10.1039/c9an01067j] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
This work showcases a PTFE-based nucleic acid extraction system for point-of-care and integration of digital PCR.
Collapse
Affiliation(s)
- Juxin Yin
- Research Centre for Analytical Instrumentation
- Institute of Cyber-Systems and Control
- State Key Laboratory of Industrial Control Technology
- Zhejiang University
- Hangzhou
| | - Jiumei Hu
- Research Centre for Analytical Instrumentation
- Institute of Cyber-Systems and Control
- State Key Laboratory of Industrial Control Technology
- Zhejiang University
- Hangzhou
| | - Jingjing Sun
- Research Centre for Analytical Instrumentation
- Institute of Cyber-Systems and Control
- State Key Laboratory of Industrial Control Technology
- Zhejiang University
- Hangzhou
| | - Ben Wang
- Cancer Institute (Key Laboratory of Cancer Prevention and Intervention
- National Ministry of Education)
- The Second Affiliated Hospital
- Zhejiang University School of Medicine
- Hangzhou
| | - Ying Mu
- Research Centre for Analytical Instrumentation
- Institute of Cyber-Systems and Control
- State Key Laboratory of Industrial Control Technology
- Zhejiang University
- Hangzhou
| |
Collapse
|
34
|
Bressan LP, de Jesus DP, Gunasekara DB, Lunte SM, da Silva JAF. Microchip Electrophoresis Containing Electrodes for Integrated Electrochemical Detection. Methods Mol Biol 2019; 1906:79-85. [PMID: 30488386 DOI: 10.1007/978-1-4939-8964-5_5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Microchip electrophoresis is a versatile separation technique. Electrochemical detection is suitable to apply to microdevices due to its easy integration to the fabrication process and good sensitivity and selectivity. Here we describe the procedures to prepare Pt band electrodes deposited on glass to couple to polydimethylsiloxane (PDMS) microchips aiming the separation and detection of nitrite using an isolated potentiostat.
Collapse
Affiliation(s)
| | | | | | - Susan Marie Lunte
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS, USA
| | | |
Collapse
|
35
|
Paschoalino WJ, Kogikoski S, Barragan JTC, Giarola JF, Cantelli L, Rabelo TM, Pessanha TM, Kubota LT. Emerging Considerations for the Future Development of Electrochemical Paper-Based Analytical Devices. ChemElectroChem 2018. [DOI: 10.1002/celc.201800677] [Citation(s) in RCA: 52] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Waldemir J. Paschoalino
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - Sergio Kogikoski
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - José T. C. Barragan
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - Juliana F. Giarola
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - Lory Cantelli
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - Thais M. Rabelo
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - Tatiana M. Pessanha
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - Lauro T. Kubota
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| |
Collapse
|
36
|
Alnaimat F, Dagher S, Mathew B, Hilal‐Alnqbi A, Khashan S. Microfluidics Based Magnetophoresis: A Review. CHEM REC 2018; 18:1596-1612. [DOI: 10.1002/tcr.201800018] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Accepted: 05/24/2018] [Indexed: 02/01/2023]
Affiliation(s)
- Fadi Alnaimat
- Mechanical Engineering DepartmentCollege of EngineeringUAE University Al Ain Abu Dhabi UAE
| | - Sawsan Dagher
- Mechanical Engineering DepartmentCollege of EngineeringUAE University Al Ain Abu Dhabi UAE
| | - Bobby Mathew
- Mechanical Engineering DepartmentCollege of EngineeringUAE University Al Ain Abu Dhabi UAE
| | - Ali Hilal‐Alnqbi
- Mechanical Engineering DepartmentCollege of EngineeringUAE University Al Ain Abu Dhabi UAE
- Abu Dhabi Polytechnic Abu Dhabi UAE
| | - Saud Khashan
- Mechanical Engineering DepartmentJordan University of Science and Technology Irbid Jordan
| |
Collapse
|
37
|
Sun S, Yang W, Zhang C, Jing J, Gao Y, Yu X, Song Q, Xiao S. Real-Time Tunable Colors from Microfluidic Reconfigurable All-Dielectric Metasurfaces. ACS NANO 2018; 12:2151-2159. [PMID: 29469563 DOI: 10.1021/acsnano.7b07121] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Structural colors arising from all-dielectric nanostructures are very promising for high-resolution color nanoprinting and high-density optical storage. However, once the all-dielectric nanostructures are fabricated, their optical performances are usually static or change slowly, significantly limiting the practical applications in advanced displays. Herein, we experimentally demonstrate the real-time tunable colors with microfluidic reconfigurable all-dielectric metasurfaces. The metasurface is composed of an array of TiO2 nanoblocks, which are embedded in a polymeric microfluidic channel. By injecting solutions with a different refractive index into the channel, the narrow band reflection peak and the corresponding distinct colors of a TiO2 metasurface can be precisely controlled. The transition time is as small as 16 ms, which is orders of magnitude faster than the current techniques. By varying the lattice size of TiO2 metasurfaces, the real-time tunable colors are able to span the entire visible spectrum. Meanwhile, the injection and ejection of solvent have also shown the capability of the erasion and the restoration of information encoded in TiO2 metasurfaces. The combination of all-dielectric nanostructures with microfluidic channels shall boost their applications in functional color display, banknote security, anticounterfeiting, and point-of-care devices.
Collapse
Affiliation(s)
- Shang Sun
- State Key Laboratory on Tunable Laser Technology, Ministry of Industry and Information Technology Key Lab of Micro-Nano Optoelectronic Information System, Shenzhen Graduate School , Harbin Institute of Technology , Shenzhen , Guangdong 518055 , P.R. China
- Collaborative Innovation Center of Extreme Optics , Shanxi University , Taiyuan , Shanxi 030006 , P.R. China
| | - Wenhong Yang
- State Key Laboratory on Tunable Laser Technology, Ministry of Industry and Information Technology Key Lab of Micro-Nano Optoelectronic Information System, Shenzhen Graduate School , Harbin Institute of Technology , Shenzhen , Guangdong 518055 , P.R. China
- Collaborative Innovation Center of Extreme Optics , Shanxi University , Taiyuan , Shanxi 030006 , P.R. China
| | - Chen Zhang
- State Key Laboratory on Tunable Laser Technology, Ministry of Industry and Information Technology Key Lab of Micro-Nano Optoelectronic Information System, Shenzhen Graduate School , Harbin Institute of Technology , Shenzhen , Guangdong 518055 , P.R. China
- Collaborative Innovation Center of Extreme Optics , Shanxi University , Taiyuan , Shanxi 030006 , P.R. China
| | - Jixiang Jing
- State Key Laboratory on Tunable Laser Technology, Ministry of Industry and Information Technology Key Lab of Micro-Nano Optoelectronic Information System, Shenzhen Graduate School , Harbin Institute of Technology , Shenzhen , Guangdong 518055 , P.R. China
- Collaborative Innovation Center of Extreme Optics , Shanxi University , Taiyuan , Shanxi 030006 , P.R. China
| | - Yisheng Gao
- State Key Laboratory on Tunable Laser Technology, Ministry of Industry and Information Technology Key Lab of Micro-Nano Optoelectronic Information System, Shenzhen Graduate School , Harbin Institute of Technology , Shenzhen , Guangdong 518055 , P.R. China
- Collaborative Innovation Center of Extreme Optics , Shanxi University , Taiyuan , Shanxi 030006 , P.R. China
| | - Xiaoyi Yu
- State Key Laboratory on Tunable Laser Technology, Ministry of Industry and Information Technology Key Lab of Micro-Nano Optoelectronic Information System, Shenzhen Graduate School , Harbin Institute of Technology , Shenzhen , Guangdong 518055 , P.R. China
- Collaborative Innovation Center of Extreme Optics , Shanxi University , Taiyuan , Shanxi 030006 , P.R. China
| | - Qinghai Song
- State Key Laboratory on Tunable Laser Technology, Ministry of Industry and Information Technology Key Lab of Micro-Nano Optoelectronic Information System, Shenzhen Graduate School , Harbin Institute of Technology , Shenzhen , Guangdong 518055 , P.R. China
- Collaborative Innovation Center of Extreme Optics , Shanxi University , Taiyuan , Shanxi 030006 , P.R. China
| | - Shumin Xiao
- State Key Laboratory on Tunable Laser Technology, Ministry of Industry and Information Technology Key Lab of Micro-Nano Optoelectronic Information System, Shenzhen Graduate School , Harbin Institute of Technology , Shenzhen , Guangdong 518055 , P.R. China
- Collaborative Innovation Center of Extreme Optics , Shanxi University , Taiyuan , Shanxi 030006 , P.R. China
| |
Collapse
|
38
|
Ai X, Lu W, Zeng K, Li C, Jiang Y, Tu P. Microfluidic Coculture Device for Monitoring of Inflammation-Induced Myocardial Injury Dynamics. Anal Chem 2018. [PMID: 29533659 DOI: 10.1021/acs.analchem.7b04833] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Emerging awareness of cardiac macrophages' role in inflammation after myocardial infarction indicates that overabundant proinflammatory macrophages induce accentuated myocardial injury. The investigation of the macrophages-cardiomyocytes interaction and inflammation-induced dynamic damage in myocardial infarction, especially in a spatiotemporally controlled manner, remains a huge challenge. Here, we developed an in vitro model using a microfluidic coculture system to mimic inflammatory cardiac injury. To our knowledge, on-chip pathological models focused on inflammation-induced myocardial injury have not been reported. The device consists of two sets of thin interconnecting grooves that isolate heterogeneous cells spatially but maintain their soluble factors communication. The mass transportation is visually characterized, and the complete diffusion reaches equilibrium within 100 s. We investigate the dynamic interaction between the macrophages and the cardiomyocytes in the spatiotemporal controlled microenvironment, mimicking a key aspect of the in vivo pathophysiological process. The results show that the activated macrophages induce time-lapsed apoptotic responses of the cardiac cells and damage mitochondria membrane integrity. The anti-inflammatory and cardio-protective effects of quercetin were explored on the chip. The extent of caspase-3 activation is asynchronous in the individual cardiac cells, suggesting the different apoptosis dynamics. We further demonstrate that the mechanism of activated inflammation is associated with the upregulation of several inflammatory cytokines and NF-κB pathway. Thus, the developed microfluidic coculture device provides a useful tool for real-time monitoring of inflammatory response for myocardial disease and holds potential for anti-inflammatory drug screening.
Collapse
Affiliation(s)
- Xiaoni Ai
- State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences , Peking University , Beijing 100191 , China
| | - Wenbo Lu
- State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences , Peking University , Beijing 100191 , China
| | - Kewu Zeng
- State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences , Peking University , Beijing 100191 , China
| | - Chun Li
- Modern Research Center for Traditional Chinese Medicine , Beijing University of Chinese Medicine , Beijing 100029 , China
| | - Yong Jiang
- State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences , Peking University , Beijing 100191 , China
| | - Pengfei Tu
- State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences , Peking University , Beijing 100191 , China
| |
Collapse
|
39
|
Wang J, Yu X, Wang Y, Pan X, Li D. Detection of viability of micro-algae cells by optofluidic hologram pattern. BIOMICROFLUIDICS 2018; 12:024111. [PMID: 29657655 PMCID: PMC5876039 DOI: 10.1063/1.5021179] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Accepted: 03/16/2018] [Indexed: 06/08/2023]
Abstract
A rapid detection of micro-algae activity is critical for analysis of ship ballast water. A new method for detecting micro-algae activity based on lens-free optofluidic holographic imaging is presented in this paper. A compact lens-free optofluidic holographic imaging device was developed. This device is mainly composed of a light source, a small through-hole, a light propagation module, a microfluidic chip, and an image acquisition and processing module. The excited light from the light source passes through a small hole to reach the surface of the micro-algae cells in the microfluidic chip, and a holographic image is formed by the diffraction light of surface of micro-algae cells. The relation between the characteristics in the hologram pattern and the activity of micro-algae cells was investigated by using this device. The characteristics of the hologram pattern were extracted to represent the activity of micro-algae cells. To demonstrate the accuracy of the presented method and device, four species of micro-algae cells were employed as the test samples and the comparison experiments between the alive and dead cells of four species of micro-algae were conducted. The results show that the developed method and device can determine live/dead microalgae cells accurately.
Collapse
Affiliation(s)
- Junsheng Wang
- College of Information and Science Technology, Dalian Maritime University, Dalian 116026, China
| | - Xiaomei Yu
- College of Information and Science Technology, Dalian Maritime University, Dalian 116026, China
| | - Yanjuan Wang
- College of Information and Science Technology, Dalian Maritime University, Dalian 116026, China
| | - Xinxiang Pan
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China
| | - Dongqing Li
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario N2L3G1, Canada
| |
Collapse
|
40
|
Shih TT, Lee HL, Chen SC, Kang CY, Shen RS, Su YA. Rapid analysis of traditional Chinese medicinePinellia ternataby microchip electrophoresis with electrochemical detection. J Sep Sci 2017; 41:740-746. [DOI: 10.1002/jssc.201700901] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2017] [Revised: 11/08/2017] [Accepted: 11/09/2017] [Indexed: 11/09/2022]
Affiliation(s)
- Tsung-Ting Shih
- Material and Chemical Research Laboratories; Industrial Technology Research Institute; Hsinchu Taiwan
| | - Hui-Ling Lee
- Department of Chemistry; Fu Jen Catholic University; New Taipei City Taiwan
| | - Show-Chuen Chen
- Department of Chemistry; Fu Jen Catholic University; New Taipei City Taiwan
| | - Chih-Yuan Kang
- Department of Chemistry; Fu Jen Catholic University; New Taipei City Taiwan
| | - Ren-Shang Shen
- Department of Chemistry; Fu Jen Catholic University; New Taipei City Taiwan
| | - Yi-An Su
- Material and Chemical Research Laboratories; Industrial Technology Research Institute; Hsinchu Taiwan
| |
Collapse
|
41
|
Saito M, Takahashi K, Kiriyama Y, Espulgar WV, Aso H, Sekiya T, Tanaka Y, Sawazumi T, Furui S, Tamiya E. Centrifugation-Controlled Thermal Convection and Its Application to Rapid Microfluidic Polymerase Chain Reaction Devices. Anal Chem 2017; 89:12797-12804. [DOI: 10.1021/acs.analchem.7b03107] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Masato Saito
- Department
of Applied Physics, Graduate School of Engineering, Osaka University, 2-1,
Yamadaoka, Suita-shi, Osaka 565-0871, Japan
| | - Kazuya Takahashi
- Department
of Applied Physics, Graduate School of Engineering, Osaka University, 2-1,
Yamadaoka, Suita-shi, Osaka 565-0871, Japan
| | - Yuichiro Kiriyama
- Department
of Applied Physics, Graduate School of Engineering, Osaka University, 2-1,
Yamadaoka, Suita-shi, Osaka 565-0871, Japan
| | - Wilfred Villariza Espulgar
- Department
of Applied Physics, Graduate School of Engineering, Osaka University, 2-1,
Yamadaoka, Suita-shi, Osaka 565-0871, Japan
| | - Hiroshi Aso
- Konica Minolta, Inc., JP Tower,
2-7-2 Marunouchi, Chiyoda-ku, Tokyo 100-7015, Japan
| | - Tadanobu Sekiya
- Konica Minolta, Inc., JP Tower,
2-7-2 Marunouchi, Chiyoda-ku, Tokyo 100-7015, Japan
| | - Yoshikazu Tanaka
- Konica Minolta, Inc., JP Tower,
2-7-2 Marunouchi, Chiyoda-ku, Tokyo 100-7015, Japan
| | - Tsuneo Sawazumi
- Konica Minolta, Inc., JP Tower,
2-7-2 Marunouchi, Chiyoda-ku, Tokyo 100-7015, Japan
| | - Satoshi Furui
- Food
Entomology Unit, Food Research Institute, NARO, 2-1-12, Kannondai,
Tsukuba, Ibaraki 305-8642, Japan
| | - Eiichi Tamiya
- Department
of Applied Physics, Graduate School of Engineering, Osaka University, 2-1,
Yamadaoka, Suita-shi, Osaka 565-0871, Japan
| |
Collapse
|
42
|
Niu P, Nablo BJ, Bhadriraju K, Reyes DR. Uncovering the Contribution of Microchannel Deformation to Impedance-Based Flow Rate Measurements. Anal Chem 2017; 89:11372-11377. [DOI: 10.1021/acs.analchem.7b02287] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Pengfei Niu
- Engineering Physics Division,
Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States
| | - Brian J. Nablo
- Engineering Physics Division,
Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States
| | - Kiran Bhadriraju
- Engineering Physics Division,
Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States
| | - Darwin R. Reyes
- Engineering Physics Division,
Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States
| |
Collapse
|
43
|
Koo KM, Wee EJH, Wang Y, Trau M. Enabling miniaturised personalised diagnostics: from lab-on-a-chip to lab-in-a-drop. LAB ON A CHIP 2017; 17:3200-3220. [PMID: 28850136 DOI: 10.1039/c7lc00587c] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The concept of personalised diagnostics is to direct accurate clinical decisions based on an individual's unique disease molecular profile. Lab-on-a-chip (LOC) systems are prime personalised diagnostics examples which seek to perform an entire sample-to-outcome detection of disease nucleic acid (NA) biomarkers on a single miniaturised platform with minimal user handling. Despite the great potential of LOC devices in providing rapid, portable, and inexpensive personalised diagnosis at the point-of-care (POC), the translation of this technology into widespread use has still been hampered by the need for sophisticated and complex engineering. As an alternative miniaturised diagnostics platform free of precision fabrication, there have been recent developments towards a solution-based lab-in-a-drop (LID) system by which an entire laboratory-based diagnostics workflow could be downscaled and integrated within a singular fluid droplet for POC detection of NA biomarkers. In contrast to existing excellent reviews on miniaturised LOC fabrication and individual steps of NA biomarker sensing, we herein focus on miniaturised solution-based NA biosensing strategies suited for integrated LID personalised diagnostics development. In this review, we first evaluate the three fundamental bioassay steps for miniaturised NA biomarker detection: crude sample preparation, isothermal target amplification, and detection readout of amplicons. Then, we provide insights into research advancements towards a functional LID system which integrates all three of the above-mentioned fundamental steps. Finally, we discuss perspectives and future directions of LID diagnostic platforms in personalised medicine applications.
Collapse
Affiliation(s)
- Kevin M Koo
- Centre for Personalised Nanomedicine, Australian Institute for Bioengineering and Nanotechnology, University of Queensland, Brisbane, QLD 4072, Australia.
| | | | | | | |
Collapse
|
44
|
Kašička V. Recent developments in capillary and microchip electroseparations of peptides (2015-mid 2017). Electrophoresis 2017; 39:209-234. [PMID: 28836681 DOI: 10.1002/elps.201700295] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 08/15/2017] [Accepted: 08/16/2017] [Indexed: 12/17/2022]
Abstract
The review brings a comprehensive overview of recent developments and applications of high performance capillary and microchip electroseparation methods (zone electrophoresis, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography, and electrochromatography) to analysis, microscale isolation, purification, and physicochemical and biochemical characterization of peptides in the years 2015, 2016, and ca. up to the middle of 2017. Advances in the investigation of electromigration properties of peptides and in the methodology of their analysis (sample preseparation, preconcentration and derivatization, adsorption suppression and EOF control, and detection) are described. New developments in particular CE and CEC methods are presented and several types of their applications to peptide analysis are reported: qualitative and quantitative analysis, determination in complex (bio)matrices, monitoring of chemical and enzymatical reactions and physical changes, amino acid, sequence and chiral analysis, and peptide mapping of proteins. Some micropreparative peptide separations are shown and capabilities of CE and CEC methods to provide important physicochemical characteristics of peptides are demonstrated.
Collapse
Affiliation(s)
- Václav Kašička
- Institute of Organic Chemistry and Biochemistry, The Czech Academy of Sciences, Prague, Czech Republic
| |
Collapse
|
45
|
Schierenbeck TM, Smith MC. Path to Impact for Autonomous Field Deployable Chemical Sensors: A Case Study of in Situ Nitrite Sensors. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2017; 51:4755-4771. [PMID: 28332819 DOI: 10.1021/acs.est.6b06171] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Natural freshwater systems have been severely affected by excess loading of macronutrients (e.g., nitrogen and phosphorus) from fertilizers, fossil fuels, and human and livestock waste. In the USA, impacts to drinking water quality, biogeochemical cycles, and aquatic ecosystems are estimated to cost US$210 billion annually. Field-deployable nutrient sensors (FDS) offer potential to support research and resource management efforts by acquiring higher resolution data than are currently supported by expensive conventional sampling methods. Following nearly 40 years of research and development, FDS instruments are now starting to penetrate commercial markets. However, instrument uncertainty factors (high cost, reliability, accuracy, and precision) are key drivers impeding the uptake of FDS by the majority of users. Using nitrite sensors as a case study, we review the trends, opportunities, and challenges in producing and implementing FDS from a perspective of innovation and impact. We characterize the user community and consumer needs, identify trends in research approaches, tabulate state-of-the-art examples and specifications, and discuss data life cycle considerations. With further development of FDS through prototyping and testing in real-world applications, these tools can deliver information for protecting and restoring natural waters, enhancing process control for industrial operations and water treatment, and providing novel research insights.
Collapse
Affiliation(s)
- Tim M Schierenbeck
- School of Freshwater Sciences, University of Wisconsin-Milwaukee , 600 E. Greenfield Avenue, Milwaukee, Wisconsin 53204, United States
| | - Matthew C Smith
- School of Freshwater Sciences, University of Wisconsin-Milwaukee , 600 E. Greenfield Avenue, Milwaukee, Wisconsin 53204, United States
| |
Collapse
|
46
|
Advances in biosensor development for the screening of antibiotic residues in food products of animal origin – A comprehensive review. Biosens Bioelectron 2017; 90:363-377. [DOI: 10.1016/j.bios.2016.12.005] [Citation(s) in RCA: 178] [Impact Index Per Article: 25.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Revised: 11/22/2016] [Accepted: 12/01/2016] [Indexed: 12/25/2022]
|
47
|
Heiland JJ, Lotter C, Stein V, Mauritz L, Belder D. Temperature Gradient Elution and Superheated Eluents in Chip-HPLC. Anal Chem 2017; 89:3266-3271. [DOI: 10.1021/acs.analchem.7b00142] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Affiliation(s)
- Josef J. Heiland
- Institute
of Analytical Chemistry, Department of Chemistry and Mineralogy, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Carsten Lotter
- Institute
of Analytical Chemistry, Department of Chemistry and Mineralogy, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Volkmar Stein
- Fraunhofer ICT-IMM, Carl-Zeiss-Straße
18-20, 55129 Mainz, Germany
| | - Laura Mauritz
- Institute
of Analytical Chemistry, Department of Chemistry and Mineralogy, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Detlev Belder
- Institute
of Analytical Chemistry, Department of Chemistry and Mineralogy, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| |
Collapse
|
48
|
Kataoka ÉM, Murer RC, Santos JM, Carvalho RM, Eberlin MN, Augusto F, Poppi RJ, Gobbi AL, Hantao LW. Simple, Expendable, 3D-Printed Microfluidic Systems for Sample Preparation of Petroleum. Anal Chem 2017; 89:3460-3467. [PMID: 28230979 DOI: 10.1021/acs.analchem.6b04413] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
In this study, we introduce a simple protocol to manufacture disposable, 3D-printed microfluidic systems for sample preparation of petroleum. This platform is produced with a consumer-grade 3D-printer, using fused deposition modeling. Successful incorporation of solid-phase extraction (SPE) to microchip was ensured by facile 3D element integration using proposed approach. This 3D-printed μSPE device was applied to challenging matrices in oil and gas industry, such as crude oil and oil-brine emulsions. Case studies investigated important limitations of nonsilicon and nonglass microchips, namely, resistance to nonpolar solvents and conservation of sample integrity. Microfluidic features remained fully functional even after prolonged exposure to nonpolar solvents (20 min). Also, 3D-printed μSPE devices enabled fast emulsion breaking and solvent deasphalting of petroleum, yielding high recovery values (98%) without compromising maltene integrity. Such finding was ascertained by high-resolution molecular analyses using comprehensive two-dimensional gas chromatography and gas chromatography/mass spectrometry by monitoring important biomarker classes, such as C10 demethylated terpanes, ααα-steranes, and monoaromatic steroids. 3D-Printed chips enabled faster and reliable preparation of maltenes by exhibiting a 10-fold reduction in sample processing time, compared to the reference method. Furthermore, polar (oxygen-, nitrogen-, and sulfur-containing) analytes found in low-concentrations were analyzed by Fourier transform ion cyclotron resonance mass spectrometry. Analysis results demonstrated that accurate characterization may be accomplished for most classes of polar compounds, except for asphaltenes, which exhibited lower recoveries (82%) due to irreversible adsorption to sorbent phase. Therefore, 3D-printing is a compelling alternative to existing microfabrication solutions, as robust devices were easy to prepare and operate.
Collapse
Affiliation(s)
- Érica M Kataoka
- Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais , Campinas, São Paulo 13083-100, Brazil
| | - Rui C Murer
- Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais , Campinas, São Paulo 13083-100, Brazil
| | - Jandyson M Santos
- Instituto de Química, Universidade Estadual de Campinas , Campinas, São Paulo 13083-970, Brazil
| | - Rogério M Carvalho
- Centro de Pesquisas e Desenvolvimento Américo Miguez de Mello, Petrobras , Rio de Janeiro, 20031-912 Brazil
| | - Marcos N Eberlin
- Instituto de Química, Universidade Estadual de Campinas , Campinas, São Paulo 13083-970, Brazil
| | - Fabio Augusto
- Instituto de Química, Universidade Estadual de Campinas , Campinas, São Paulo 13083-970, Brazil
| | - Ronei J Poppi
- Instituto de Química, Universidade Estadual de Campinas , Campinas, São Paulo 13083-970, Brazil
| | - Angelo L Gobbi
- Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais , Campinas, São Paulo 13083-100, Brazil
| | - Leandro W Hantao
- Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais , Campinas, São Paulo 13083-100, Brazil.,Instituto de Química, Universidade Estadual de Campinas , Campinas, São Paulo 13083-970, Brazil
| |
Collapse
|
49
|
|
50
|
Solid supports for extraction and preconcentration of proteins and peptides in microfluidic devices: A review. Anal Chim Acta 2016; 955:1-26. [PMID: 28088276 DOI: 10.1016/j.aca.2016.12.017] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2016] [Revised: 12/02/2016] [Accepted: 12/07/2016] [Indexed: 01/08/2023]
Abstract
Determination of proteins and peptides is among the main challenges of today's bioanalytical chemistry. The application of microchip technology in this field is an exhaustively developed concept that aims to create integrated and fully automated analytical devices able to quantify or detect one or several proteins from a complex matrix. Selective extraction and preconcentration of targeted proteins and peptides especially from biological fluids is of the highest importance for a successful realization of these microsystems. Incorporation of solid structures or supports is a convenient solution employed to face these demands. This review presents a critical view on the latest achievements in sample processing techniques for protein determination using solid supports in microfluidics. The study covers the period from 2006 to 2015 and focuses mainly on the strategies based on microbeads, monolithic materials and membranes. Less common approaches are also briefly discussed. The reviewed literature suggests future trends which are discussed in the concluding remarks.
Collapse
|