Suzuki T, Ito C, Kitano K, Yamaguchi T. CIELAB Color Space as a Field for Tracking Color-Changing Chemical Reactions of Polymeric pH Indicators. ACS OMEGA 2024; 9:36682-36689. [PMID: 39220493 PMCID: PMC11360014 DOI: 10.1021/acsomega.4c05320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Revised: 08/02/2024] [Accepted: 08/06/2024] [Indexed: 09/04/2024]
Abstract
Two types of cross-linked polymeric dye films that exhibit reversible color changes in response to pH were prepared. Upon protonation, films with a nitrophenol dye moiety (NP) changed from yellow to colorless, whereas films with an azobenzene dye moiety (AB) changed from yellow to reddish-purple. The colored light transmitted through these films from a D65 white-light source was measured colorimetrically, and the transition of the chromaticity point in CIELAB upon protonation of the polymeric dyes was observed. At low dye concentrations ([NP] < 4.7 × 10-5 and [AB] < 2.7 × 10-5 mol L-1), linear loci of the chromaticity points were displayed for both polymeric dye films, indicating perceptual linearity. This linearity is caused by the avoidance of nonlinear perceptual phenomena such as the Abney effect and the Bezold-Brücke phenomenon. The perceptual linearity of space is a necessary condition for achieving stoichiometric linearity, which requires an additional linear relationship between the dye concentration and each component, a*, b*, and L*. A geometric equation that included the AB concentration and the protonation ratio of AB was used to successfully depict, on the basis of stoichiometric linearity, the protonation of the polymeric AB films three-dimensionally in the restricted area of CIELAB.
Collapse
Affiliation(s)
- Takayuki Suzuki
- Department of Applied Chemistry,
School of Engineering, Tokyo Denki University, 5 Senjyu Asahi-cho, Adachi, Tokyo 120-8551, Japan
| | - Chihiro Ito
- Department of Applied Chemistry,
School of Engineering, Tokyo Denki University, 5 Senjyu Asahi-cho, Adachi, Tokyo 120-8551, Japan
| | - Karen Kitano
- Department of Applied Chemistry,
School of Engineering, Tokyo Denki University, 5 Senjyu Asahi-cho, Adachi, Tokyo 120-8551, Japan
| | - Tomohiro Yamaguchi
- Department of Applied Chemistry,
School of Engineering, Tokyo Denki University, 5 Senjyu Asahi-cho, Adachi, Tokyo 120-8551, Japan
| |
Collapse
|
2
|
Akuoko SY, Kwon KS. Fabrication and Applications of Nature-Inspired Surfaces with Selective Wettability. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:15969-15995. [PMID: 39046090 DOI: 10.1021/acs.langmuir.4c00919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/25/2024]
Abstract
Inspired by the Stenocora beetle, selective wettability surfaces incorporate alternating wettable and nonwettable surface features that have received substantial attention over the past two decades. These surfaces are sought after for their very promising potential to drive progress in numerous application fields, including ecological protection, biomedical sciences, and industrial technologies. However, despite ongoing efforts to produce such surfaces in commercial quantities, understanding their basic fabrication concepts for practical applications can be challenging, especially for novices, given the vast technical literature in this area. This review, therefore, aims to elucidate the principles of wettability, along with the evolution of selective wettability surfaces and their uses. Beginning with a summary of the essential history and theory of wetting, we explore naturally occurring surfaces that have influenced wetting studies. We then detail state-of-the-art methods for fabricating these unique biwetting surfaces and show how contemporary science employs such designs in solving real-world problems. Finally, we offer an outlook for future research prospects on scalable, printing-based fabrication methods.
Collapse
Affiliation(s)
- Stephen Yaw Akuoko
- Department of Electronic Materials, Devices and Equipment Engineering, Soonchunhyang University, 22 Soonchunhyang-ro, Asan, Chungnam 31538, South Korea
| | - Kye-Si Kwon
- Department of Electronic Materials, Devices and Equipment Engineering, Soonchunhyang University, 22 Soonchunhyang-ro, Asan, Chungnam 31538, South Korea
- Department of Mechanical Engineering, Soonchunhyang University, 22 Soonchunhyang-ro, Asan, Chungnam 31538, South Korea
| |
Collapse
|
3
|
Qin M, Khan IM, Ding N, Qi S, Dong X, Zhang Y, Wang Z. Aptamer-modified paper-based analytical devices for the detection of food hazards: Emerging applications and future perspective. Biotechnol Adv 2024; 73:108368. [PMID: 38692442 DOI: 10.1016/j.biotechadv.2024.108368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 03/10/2024] [Accepted: 04/24/2024] [Indexed: 05/03/2024]
Abstract
Food analysis plays a critical role in assessing human health risks and monitoring food quality and safety. Currently, there is a pressing need for a reliable, portable, and quick recognition element for point-of-care testing (POCT) to better serve the demands of on-site food analysis. Aptamer-modified paper-based analytical devices (Apt-PADs) have excellent characteristics of high portability, high sensitivity, high specificity, and on-site detection, which have been widely used and concerned in the field of food safety. The article reviews the basic components and working principles of Apt-PADs, and introduces their representative applications detecting food hazards. Finally, the advantages, challenges, and future directions of Apt-PADs-based sensing performance are discussed, to provide new directions and insights for researchers to select appropriate Apt-PADs according to specific applications.
Collapse
Affiliation(s)
- Mingwei Qin
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Imran Mahmood Khan
- Nottingham Ningbo China Beacons of Excellence Research and Innovation Institute, University of Nottingham Ningbo China, Ningbo 315100, PR China
| | - Ning Ding
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Shuo Qi
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Xiaoze Dong
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Yin Zhang
- Key Laboratory of Meat Processing of Sichuan, Chengdu University, Chengdu 610106, China
| | - Zhouping Wang
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China; Key Laboratory of Meat Processing of Sichuan, Chengdu University, Chengdu 610106, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China; National Engineering Research Center for Functional Food, Jiangnan University, Wuxi 214122, China.
| |
Collapse
|
4
|
Mazur F, Han Z, Tjandra AD, Chandrawati R. Digitalization of Colorimetric Sensor Technologies for Food Safety. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024:e2404274. [PMID: 38932639 DOI: 10.1002/adma.202404274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2024] [Revised: 06/06/2024] [Indexed: 06/28/2024]
Abstract
Colorimetric sensors play a crucial role in promoting on-site testing, enabling the detection and/or quantification of various analytes based on changes in color. These sensors offer several advantages, such as simplicity, cost-effectiveness, and visual readouts, making them suitable for a wide range of applications, including food safety and monitoring. A critical component in portable colorimetric sensors involves their integration with color models for effective analysis and interpretation of output signals. The most commonly used models include CIELAB (Commission Internationale de l'Eclairage), RGB (Red, Green, Blue), and HSV (Hue, Saturation, Value). This review outlines the use of color models via digitalization in sensing applications within the food safety and monitoring field. Additionally, challenges, future directions, and considerations are discussed, highlighting a significant gap in integrating a comparative analysis toward determining the color model that results in the highest sensor performance. The aim of this review is to underline the potential of this integration in mitigating the global impact of food spoilage and contamination on health and the economy, proposing a multidisciplinary approach to harness the full capabilities of colorimetric sensors in ensuring food safety.
Collapse
Affiliation(s)
- Federico Mazur
- School of Chemical Engineering and Australian Centre for Nanomedicine (ACN), The University of New South Wales, Sydney, NSW, 2052, Australia
| | - Zifei Han
- School of Chemical Engineering and Australian Centre for Nanomedicine (ACN), The University of New South Wales, Sydney, NSW, 2052, Australia
| | - Angie Davina Tjandra
- School of Chemical Engineering and Australian Centre for Nanomedicine (ACN), The University of New South Wales, Sydney, NSW, 2052, Australia
| | - Rona Chandrawati
- School of Chemical Engineering and Australian Centre for Nanomedicine (ACN), The University of New South Wales, Sydney, NSW, 2052, Australia
| |
Collapse
|
5
|
Chen JS, Wang CM, Chiang PY, Lo LC, Liao WS. Spatially Mediated Paper Reactors for On-Site Multicoded Encryption. JACS AU 2024; 4:2151-2159. [PMID: 38938820 PMCID: PMC11200220 DOI: 10.1021/jacsau.4c00062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 03/22/2024] [Accepted: 04/02/2024] [Indexed: 06/29/2024]
Abstract
This report develops a point-of-use chemical trigger and applies it to a dual-functional chemical encryption chip that enables manual and digital identification with enhanced coding security levels suitable for on-site information verification. The concept relies on conducting continuous chemical synthesis and chromatographic separation of specified compounds on a paper device in a straightforward sketch. In addition to single-step chemical reactions, cascade syntheses and operations involving components of distinct mobilities are also demonstrated. The condensation of dione and hydrazine is first demonstrated on a linear paper reactor, where precursors can mix to react, followed by final product separation under optimized conditions. This linear paper reactor design can also support a multistep cascade Wittig reaction by controlling the relative mobility of reactants, intermediates, and final products. Furthermore, a three-dimensional paper reactor with appropriate mobile phases helps to initiate complex solvent system-driven azide-alkyne cycloaddition. By the use of a three-dimensional device design for spatially limited interdevice reactant transportation, reactants crossing designated boundaries trigger confined chemical reactions at specific positions. Accumulation of repetitive reactions leads to successful product gradient generation and mixing effects, representing a fully controllable intersubstrate chemical operation on the platform. Standing on initiating desired chemical reactions at particular interface regions, integration of appropriate selective reaction area, numerical digits overlay, color diversity, and mobile recognition realizes this dual-functional multicoding encryption process.
Collapse
Affiliation(s)
- Jia-Syuan Chen
- Department
of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| | - Chang-Ming Wang
- Department
of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| | - Po-Yu Chiang
- Department
of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| | - Lee-Chiang Lo
- Department
of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| | - Wei-Ssu Liao
- Department
of Chemistry, National Taiwan University, Taipei 10617, Taiwan
- Center
for Emerging Material and Advanced Devices, National Taiwan University, Taipei 10617, Taiwan
| |
Collapse
|
6
|
Chen JL, Njoku DI, Tang C, Gao Y, Chen J, Peng YK, Sun H, Mao G, Pan M, Tam NFY. Advances in Microfluidic Paper-Based Analytical Devices (µPADs): Design, Fabrication, and Applications. SMALL METHODS 2024:e2400155. [PMID: 38781604 DOI: 10.1002/smtd.202400155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 05/01/2024] [Indexed: 05/25/2024]
Abstract
Microfluidic Paper-based Analytical Devices (µPADs) have emerged as a new class of microfluidic systems, offering numerous advantages over traditional microfluidic chips. These advantages include simplicity, cost-effectiveness, stability, storability, disposability, and portability. As a result, various designs for different types of assays are developed and investigated. In recent years, µPADs are combined with conventional detection methods to enable rapid on-site detection, providing results comparable to expensive and sophisticated large-scale testing methods that require more time and skilled personnel. The application of µPAD techniques is extensive in environmental quality control/analysis, clinical diagnosis, and food safety testing, paving the way for on-site real-time diagnosis as a promising future development. This review focuses on the recent research advancements in the design, fabrication, material selection, and detection methods of µPADs. It provides a comprehensive understanding of their principles of operation, applications, and future development prospects.
Collapse
Affiliation(s)
- Jian Lin Chen
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
| | - Demian Ifeanyi Njoku
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Cui Tang
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Yaru Gao
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Jiayu Chen
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Yung-Kang Peng
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
| | - Hongyan Sun
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
| | - Guozhu Mao
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300350, P. R. China
| | - Min Pan
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Nora Fung-Yee Tam
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
| |
Collapse
|
7
|
Malik S, Singh J, Saini K, Chaudhary V, Umar A, Ibrahim AA, Akbar S, Baskoutas S. Paper-based sensors: affordable, versatile, and emerging analyte detection platforms. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2777-2809. [PMID: 38639474 DOI: 10.1039/d3ay02258g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
Paper-based sensors, often referred to as paper-based analytical devices (PADs), stand as a transformative technology in the field of analytical chemistry. They offer an affordable, versatile, and accessible solution for diverse analyte detection. These sensors harness the unique properties of paper substrates to provide a cost-effective and adaptable platform for rapid analyte detection, spanning chemical species, biomolecules, and pathogens. This review highlights the key attributes that make paper-based sensors an attractive choice for analyte detection. PADs demonstrate their versatility by accommodating a wide range of analytes, from ions and gases to proteins, nucleic acids, and more, with customizable designs for specific applications. Their user-friendly operation and minimal infrastructure requirements suit point-of-care diagnostics, environmental monitoring, food safety, and more. This review also explores various fabrication methods such as inkjet printing, wax printing, screen printing, dip coating, and photolithography. Incorporating nanomaterials and biorecognition elements promises even more sophisticated and sensitive applications.
Collapse
Affiliation(s)
- Sumit Malik
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Joginder Singh
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Kajal Saini
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Vivek Chaudhary
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Ahmad Umar
- Department of Chemistry, Faculty of Science and Arts, Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, Najran-11001, Kingdom of Saudi Arabia.
- Department of Materials Science and Engineering, The Ohio State University, Columbus 43210, OH, USA
- STEM Pioneers Training Lab, Najran University, Najran 11001, Kingdom of Saudi Arabia
| | - Ahmed A Ibrahim
- Department of Chemistry, Faculty of Science and Arts, Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, Najran-11001, Kingdom of Saudi Arabia.
- STEM Pioneers Training Lab, Najran University, Najran 11001, Kingdom of Saudi Arabia
| | - Sheikh Akbar
- Department of Materials Science and Engineering, The Ohio State University, Columbus 43210, OH, USA
| | | |
Collapse
|
8
|
Soman SS, Samad SA, Venugopalan P, Kumawat N, Kumar S. Microfluidic paper analytic device (μPAD) technology for food safety applications. BIOMICROFLUIDICS 2024; 18:031501. [PMID: 38706979 PMCID: PMC11068414 DOI: 10.1063/5.0192295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 04/15/2024] [Indexed: 05/07/2024]
Abstract
Foodborne pathogens, food adulterants, allergens, and toxic chemicals in food can cause major health hazards to humans and animals. Stringent quality control measures at all stages of food processing are required to ensure food safety. There is, therefore, a global need for affordable, reliable, and rapid tests that can be conducted at different process steps and processing sites, spanning the range from the sourcing of food to the end-product acquired by the consumer. Current laboratory-based food quality control tests are well established, but many are not suitable for rapid on-site investigations and are costly. Microfluidic paper analytical devices (μPADs) are a fast-growing field in medical diagnostics that can fill these gaps. In this review, we describe the latest developments in the applications of microfluidic paper analytic device (μPAD) technology in the food safety sector. State-of-the-art μPAD designs and fabrication methods, microfluidic assay principles, and various types of μPAD devices with food-specific applications are discussed. We have identified the prominent research and development trends and future directions for maximizing the value of microfluidic technology in the food sector and have highlighted key areas for improvement. We conclude that the μPAD technology is promising in food safety applications by using novel materials and improved methods to enhance the sensitivity and specificity of the assays, with low cost.
Collapse
Affiliation(s)
- Soja Saghar Soman
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, P.O. Box 129188, UAE
| | - Shafeek Abdul Samad
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, P.O. Box 129188, UAE
| | | | - Nityanand Kumawat
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, P.O. Box 129188, UAE
| | | |
Collapse
|
9
|
Carou-Senra P, Rodríguez-Pombo L, Awad A, Basit AW, Alvarez-Lorenzo C, Goyanes A. Inkjet Printing of Pharmaceuticals. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2309164. [PMID: 37946604 DOI: 10.1002/adma.202309164] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/23/2023] [Indexed: 11/12/2023]
Abstract
Inkjet printing (IJP) is an additive manufacturing process that selectively deposits ink materials, layer-by-layer, to create 3D objects or 2D patterns with precise control over their structure and composition. This technology has emerged as an attractive and versatile approach to address the ever-evolving demands of personalized medicine in the healthcare industry. Although originally developed for nonhealthcare applications, IJP harnesses the potential of pharma-inks, which are meticulously formulated inks containing drugs and pharmaceutical excipients. Delving into the formulation and components of pharma-inks, the key to precise and adaptable material deposition enabled by IJP is unraveled. The review extends its focus to substrate materials, including paper, films, foams, lenses, and 3D-printed materials, showcasing their diverse advantages, while exploring a wide spectrum of therapeutic applications. Additionally, the potential benefits of hardware and software improvements, along with artificial intelligence integration, are discussed to enhance IJP's precision and efficiency. Embracing these advancements, IJP holds immense potential to reshape traditional medicine manufacturing processes, ushering in an era of medical precision. However, further exploration and optimization are needed to fully utilize IJP's healthcare capabilities. As researchers push the boundaries of IJP, the vision of patient-specific treatment is on the horizon of becoming a tangible reality.
Collapse
Affiliation(s)
- Paola Carou-Senra
- Departamento de Farmacología, Farmacia y Tecnología Farmacéutica, I+D Farma Group (GI-1645), Facultad de Farmacia, Instituto de Materiales (iMATUS) and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, Santiago de Compostela, 15782, Spain
| | - Lucía Rodríguez-Pombo
- Departamento de Farmacología, Farmacia y Tecnología Farmacéutica, I+D Farma Group (GI-1645), Facultad de Farmacia, Instituto de Materiales (iMATUS) and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, Santiago de Compostela, 15782, Spain
| | - Atheer Awad
- Department of Clinical, Pharmaceutical and Biological Sciences, University of Hertfordshire, College Lane, Hatfield, AL10 9AB, UK
| | - Abdul W Basit
- Department of Pharmaceutics, UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London, WC1N 1AX, UK
- FABRX Ltd., Henwood House, Henwood, Ashford, Kent, TN24 8DH, UK
- FABRX Artificial Intelligence, Carretera de Escairón 14, Currelos (O Saviñao), CP 27543, Spain
| | - Carmen Alvarez-Lorenzo
- Departamento de Farmacología, Farmacia y Tecnología Farmacéutica, I+D Farma Group (GI-1645), Facultad de Farmacia, Instituto de Materiales (iMATUS) and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, Santiago de Compostela, 15782, Spain
| | - Alvaro Goyanes
- Departamento de Farmacología, Farmacia y Tecnología Farmacéutica, I+D Farma Group (GI-1645), Facultad de Farmacia, Instituto de Materiales (iMATUS) and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, Santiago de Compostela, 15782, Spain
- Department of Pharmaceutics, UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London, WC1N 1AX, UK
- FABRX Ltd., Henwood House, Henwood, Ashford, Kent, TN24 8DH, UK
- FABRX Artificial Intelligence, Carretera de Escairón 14, Currelos (O Saviñao), CP 27543, Spain
| |
Collapse
|
10
|
Liang M, Zhang G, Song J, Tan M, Su W. Paper-Based Microfluidic Chips for Food Hazard Factor Detection: Fabrication, Modification, and Application. Foods 2023; 12:4107. [PMID: 38002165 PMCID: PMC10670051 DOI: 10.3390/foods12224107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 11/07/2023] [Accepted: 11/09/2023] [Indexed: 11/26/2023] Open
Abstract
Food safety and quality are paramount concerns for ensuring the preservation of human life and well-being. As the field of food processing continues to advance, there is a growing interest in the development of fast, instant, cost-effective, and convenient methods for detecting food safety issues. In this context, the utilization of paper-based microfluidic chips has emerged as a promising platform for enabling rapid detection, owing to their compact size, high throughput capabilities, affordability, and low resource consumption, among other advantages. To shed light on this topic, this review article focuses on the functionalization of paper-based microfluidic surfaces and provides an overview of the latest research and applications to colorimetric analysis, fluorescence analysis, surface-enhanced Raman spectroscopy, as well as their integration with paper-based microfluidic platforms for achieving swift and reliable food safety detection. Lastly, the article deliberates on the challenges these analytical methods and presents insights into their future development prospects in facilitating rapid food safety assessment.
Collapse
Affiliation(s)
- Meiqi Liang
- Academy of Food Interdisciplinary Science, School of Food Science and Technology, Dalian Polytechnic University, Dalian 116034, China; (M.L.); (G.Z.); (J.S.); (M.T.)
- National Engineering Research Center of Seafood, Dalian 116034, China
- SKL of Marine Food Processing & Safety Control, Dalian Polytechnic University, Dalian 116034, China
| | - Guozhi Zhang
- Academy of Food Interdisciplinary Science, School of Food Science and Technology, Dalian Polytechnic University, Dalian 116034, China; (M.L.); (G.Z.); (J.S.); (M.T.)
- National Engineering Research Center of Seafood, Dalian 116034, China
- SKL of Marine Food Processing & Safety Control, Dalian Polytechnic University, Dalian 116034, China
| | - Jie Song
- Academy of Food Interdisciplinary Science, School of Food Science and Technology, Dalian Polytechnic University, Dalian 116034, China; (M.L.); (G.Z.); (J.S.); (M.T.)
- National Engineering Research Center of Seafood, Dalian 116034, China
- SKL of Marine Food Processing & Safety Control, Dalian Polytechnic University, Dalian 116034, China
| | - Mingqian Tan
- Academy of Food Interdisciplinary Science, School of Food Science and Technology, Dalian Polytechnic University, Dalian 116034, China; (M.L.); (G.Z.); (J.S.); (M.T.)
- National Engineering Research Center of Seafood, Dalian 116034, China
- SKL of Marine Food Processing & Safety Control, Dalian Polytechnic University, Dalian 116034, China
| | - Wentao Su
- Academy of Food Interdisciplinary Science, School of Food Science and Technology, Dalian Polytechnic University, Dalian 116034, China; (M.L.); (G.Z.); (J.S.); (M.T.)
- National Engineering Research Center of Seafood, Dalian 116034, China
- SKL of Marine Food Processing & Safety Control, Dalian Polytechnic University, Dalian 116034, China
| |
Collapse
|
11
|
Kumari R, Singh A, Azad UP, Chandra P. Insights into the Fabrication and Electrochemical Aspects of Paper Microfluidics-Based Biosensor Module. BIOSENSORS 2023; 13:891. [PMID: 37754125 PMCID: PMC10526938 DOI: 10.3390/bios13090891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 09/08/2023] [Accepted: 09/14/2023] [Indexed: 09/28/2023]
Abstract
Over the past ten years, microfluidic paper-based analytical devices (micro-PADs) have attracted a lot of attention as a viable analytical platform. It is expanding as a result of advances in manufacturing processes and device integration. Conventional microfluidics approaches have some drawbacks, including high costs, lengthy evaluation times, complicated fabrication, and the necessity of experienced employees. Hence, it is extremely important to construct a detection system that is quick, affordable, portable, and efficient. Nowadays, micro-PADs are frequently employed, particularly in electrochemical analyses, to replicate the classic standard laboratory experiments on a miniature paper chip. It has benefits like rapid assessment, small sample consumption, quick reaction, accuracy, and multiplex function. The goal of this review is to examine modern paper microfluidics-based electrochemical sensing devices for the detection of macromolecules, small molecules, and cells in a variety of real samples. The design and fabrication of micro-PADs using conventional and the latest techniques have also been discussed in detail. Lastly, the limitations and potential of these analytical platforms are examined in order to shed light on future research.
Collapse
Affiliation(s)
- Rohini Kumari
- Laboratory of Bio-Physio Sensors and Nanobioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi 221005, Uttar Pradesh, India; (R.K.); (A.S.)
| | - Akanksha Singh
- Laboratory of Bio-Physio Sensors and Nanobioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi 221005, Uttar Pradesh, India; (R.K.); (A.S.)
| | - Uday Pratap Azad
- Laboratory of Nanoelectrochemistry, Department of Chemistry, Guru Ghasidas Vishwavidyalaya (Central University), Bilaspur 495009, Chhattisgarh, India;
| | - Pranjal Chandra
- Laboratory of Bio-Physio Sensors and Nanobioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi 221005, Uttar Pradesh, India; (R.K.); (A.S.)
| |
Collapse
|
12
|
Musile G, Grazioli C, Fornasaro S, Dossi N, De Palo EF, Tagliaro F, Bortolotti F. Application of Paper-Based Microfluidic Analytical Devices (µPAD) in Forensic and Clinical Toxicology: A Review. BIOSENSORS 2023; 13:743. [PMID: 37504142 PMCID: PMC10377625 DOI: 10.3390/bios13070743] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 06/14/2023] [Accepted: 06/23/2023] [Indexed: 07/29/2023]
Abstract
The need for providing rapid and, possibly, on-the-spot analytical results in the case of intoxication has prompted researchers to develop rapid, sensitive, and cost-effective methods and analytical devices suitable for use in nonspecialized laboratories and at the point of need (PON). In recent years, the technology of paper-based microfluidic analytical devices (μPADs) has undergone rapid development and now provides a feasible, low-cost alternative to traditional rapid tests for detecting harmful compounds. In fact, µPADs have been developed to detect toxic molecules (arsenic, cyanide, ethanol, and nitrite), drugs, and drugs of abuse (benzodiazepines, cathinones, cocaine, fentanyl, ketamine, MDMA, morphine, synthetic cannabinoids, tetrahydrocannabinol, and xylazine), and also psychoactive substances used for drug-facilitated crimes (flunitrazepam, gamma-hydroxybutyric acid (GHB), ketamine, metamizole, midazolam, and scopolamine). The present report critically evaluates the recent developments in paper-based devices, particularly in detection methods, and how these new analytical tools have been tested in forensic and clinical toxicology, also including future perspectives on their application, such as multisensing paper-based devices, microfluidic paper-based separation, and wearable paper-based sensors.
Collapse
Affiliation(s)
- Giacomo Musile
- Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, P.le Scuro 10, 37134 Verona, Italy
| | - Cristian Grazioli
- Department of Agrifood, Environmental and Animal Science, University of Udine, Via Cotonificio 108, 33100 Udine, Italy
| | - Stefano Fornasaro
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgeri 1, 34127 Trieste, Italy
| | - Nicolò Dossi
- Department of Agrifood, Environmental and Animal Science, University of Udine, Via Cotonificio 108, 33100 Udine, Italy
| | - Elio Franco De Palo
- Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, P.le Scuro 10, 37134 Verona, Italy
| | - Franco Tagliaro
- Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, P.le Scuro 10, 37134 Verona, Italy
- Laboratory of Pharmacokinetics and Metabolomics Analysis, Institute of Translational Medicine and Biotechnology, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street, 119991 Moscow, Russia
| | - Federica Bortolotti
- Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, P.le Scuro 10, 37134 Verona, Italy
| |
Collapse
|
13
|
Prakobkij A, Sukapanon S, Chunta S, Jarujamrus P. Mickey mouse-shaped laminated paper-based analytical device in simultaneous total cholesterol and glucose determination in whole blood. Anal Chim Acta 2023; 1263:341303. [PMID: 37225342 DOI: 10.1016/j.aca.2023.341303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2023] [Revised: 04/27/2023] [Accepted: 04/28/2023] [Indexed: 05/26/2023]
Abstract
The microfluidic paper-based analytical device (μPAD) platform is gaining attention as a low-cost, portable, and disposable detection tool. However, the limitations of traditional fabrication methods include poor reproducibility and the use of hydrophobic reagents. In this study, an in-house computer-controlled X-Y knife plotter and pen plotter were used to fabricate μPADs, resulting in a simple, more rapid, reproducible process that consumes less volume of reagents. The μPADs were laminated to increase mechanical strength and reduce sample evaporation during analysis. The resulting laminated paper-based analytical device (LPAD) was used to simultaneously determine glucose and total cholesterol in whole blood using the LF1 membrane as a sample zone. The LF1 membrane selectively separates plasma from whole blood by size exclusion and yields plasma for further enzymatic reaction steps while retaining blood cells and larger proteins. The i1 Pro 3 mini spectrophotometer directly detected color on the LPAD. The results were clinically relevant and in agreement with hospital methods, with a detection limit of 0.16 mmol L⁻1 for glucose and 0.57 mmol L⁻1 for TC. The LPAD retained color intensity after 60 days of storage. The LPAD offers a low-cost, high-performance option for chemical sensing devices and expands the applicability of markers for diagnosing whole blood samples.
Collapse
Affiliation(s)
- Akarapong Prakobkij
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand; Nanomaterials Science, Sensors & Catalysis for Problem-Based Projects, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand
| | - Suchada Sukapanon
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand; Nanomaterials Science, Sensors & Catalysis for Problem-Based Projects, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand
| | - Suticha Chunta
- Department of Clinical Chemistry, Faculty of Medical Technology, Prince of Songkla University, Songkhla, 90110, Thailand
| | - Purim Jarujamrus
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand; Nanomaterials Science, Sensors & Catalysis for Problem-Based Projects, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
| |
Collapse
|
14
|
Pettinau F, Pittau B, Orrù A. Paper microzone assay embedded on a 3D printed support for colorimetric quantification of proteins in different biological and food samples. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023. [PMID: 37309579 DOI: 10.1039/d3ay00597f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
This study describes the development of a paper microzone colorimetric assay embedded on a 3D printed support for quantifying total protein content in different biological matrices and foods. The aim was to develop an accurate and reliable method, ensuring at the same time the possibility of customizability, facility of use, wide applicability, and reduced analysis for both time and costs. The device consists of a 3D printed thermoplastic polyurethane support housing the detection substrate (GF/F glass microfiber). The bromophenol blue (BPB) assay was optimized in this substrate to quantify total protein content. The analytical performance, assessed through image analysis, indicated that the hue factor of the HSV colour space represents the best analytical signal (r2 > 0.98%). The optimized assay ensures a sufficiently low limit of detection (0.05 mg mL-1), and an accuracy between 92% and 95%. The bioanalytical feasibility was demonstrated through total protein concentration measurement in different biological matrices (bee venom and mouse brain tissue), and foods (soya milk, cow's milk and protein supplements). The obtained values showed a strong agreement with those derived from a standard spectrophotometric analysis. Overall, the paper microzone BPB assay may represent an important contribution to protein quantification technology and could significantly impact many areas, such as quality control analysis and pre-clinical laboratory analysis.
Collapse
Affiliation(s)
- Francesca Pettinau
- Institute of Translational Pharmacology, National Research Council, Parco Scientifico e Tecnologico della Sardegna, Polaris - Edificio 5 - Località, Piscinamanna, 09010 Pula (CA), Italy.
| | - Barbara Pittau
- Institute of Translational Pharmacology, National Research Council, Parco Scientifico e Tecnologico della Sardegna, Polaris - Edificio 5 - Località, Piscinamanna, 09010 Pula (CA), Italy.
| | - Alessandro Orrù
- Institute of Translational Pharmacology, National Research Council, Parco Scientifico e Tecnologico della Sardegna, Polaris - Edificio 5 - Località, Piscinamanna, 09010 Pula (CA), Italy.
| |
Collapse
|
15
|
Ebrahimi G, Pakchin PS, Mota A, Omidian H, Omidi Y. Electrochemical microfluidic paper-based analytical devices for cancer biomarker detection: From 2D to 3D sensing systems. Talanta 2023; 257:124370. [PMID: 36858013 DOI: 10.1016/j.talanta.2023.124370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 02/06/2023] [Accepted: 02/13/2023] [Indexed: 02/18/2023]
Abstract
Microfluidic paper-based analytical devices (μPADs) offer a unique possibility for a cost-effective portable and rapid detection of a wide range of small molecules and macromolecules and even microorganisms. In this line, electrochemical detection methods are key techniques for the qualitative analysis of different types of ligands. The electrochemical sensing μPADs have been devised for the rapid, accurate, and quantitative detection of oncomarkers through two-/three-dimensional (2D/3D) approaches. The 2D μPADs were first developed and then transformed into 3D systems via folding and/or twisting of paper. The microfluidic channels and connections were created within the layers of paper. Based on the fabrication methods, 3D μPADs can be classified into origami and stacking devices. Various fabrication methods and materials have been used to create hydrophilic channels in μPADs, among which the wax printing technique is the most common method in fabricating μPADs. In this review, we discuss the fabrication and design strategies of μPADs, elaborate on their detection modes, and highlight their applications in affinity-based electrochemical μPADs methods for the detection of oncomarkers.
Collapse
Affiliation(s)
- Ghasem Ebrahimi
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran; Department of Biochemistry and Clinical Laboratories, Faculty of Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Parvin Samadi Pakchin
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Ali Mota
- Department of Biochemistry and Clinical Laboratories, Faculty of Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Hossein Omidian
- Department of Pharmaceutical Sciences, College of Pharmacy, Nova Southeastern University, Fort Lauderdale, FL, 33328, USA
| | - Yadollah Omidi
- Department of Pharmaceutical Sciences, College of Pharmacy, Nova Southeastern University, Fort Lauderdale, FL, 33328, USA.
| |
Collapse
|
16
|
Khan M, Zhao B, Wu W, Zhao M, Bi Y, Hu Q. Distance-based microfluidic assays for instrument-free visual point-of-care testing. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
|
17
|
Mitrogiannopoulou AM, Tselepi V, Ellinas K. Polymeric and Paper-Based Lab-on-a-Chip Devices in Food Safety: A Review. MICROMACHINES 2023; 14:986. [PMID: 37241610 PMCID: PMC10223399 DOI: 10.3390/mi14050986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 04/27/2023] [Accepted: 04/28/2023] [Indexed: 05/28/2023]
Abstract
Food quality and safety are important to protect consumers from foodborne illnesses. Currently, laboratory scale analysis, which takes several days to complete, is the main way to ensure the absence of pathogenic microorganisms in a wide range of food products. However, new methods such as PCR, ELISA, or even accelerated plate culture tests have been proposed for the rapid detection of pathogens. Lab-on-chip (LOC) devices and microfluidics are miniaturized devices that can enable faster, easier, and at the point of interest analysis. Nowadays, methods such as PCR are often coupled with microfluidics, providing new LOC devices that can replace or complement the standard methods by offering highly sensitive, fast, and on-site analysis. This review's objective is to present an overview of recent advances in LOCs used for the identification of the most prevalent foodborne and waterborne pathogens that put consumer health at risk. In particular, the paper is organized as follows: first, we discuss the main fabrication methods of microfluidics as well as the most popular materials used, and then we present recent literature examples for LOCs used for the detection of pathogenic bacteria found in water and other food samples. In the final section, we summarize our findings and also provide our point of view on the challenges and opportunities in the field.
Collapse
Affiliation(s)
| | | | - Kosmas Ellinas
- Department of Food Science and Nutrition, School of the Environment, University of the Aegean, Ierou Lochou & Makrygianni St, GR 81400 Myrina, Greece
| |
Collapse
|
18
|
Roller RM, Rea A, Lieberman M. The air-gap PAD: a roll-to-roll-compatible fabrication method for paper microfluidics. LAB ON A CHIP 2023; 23:1918-1925. [PMID: 36883463 DOI: 10.1039/d2lc01164f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Paper-based analytical devices (PADs) offer a low-cost, user-friendly platform for rapid point-of-use testing. Without scalable fabrication methods, however, few PADs make it out of the academic laboratory and into the hands of end users. Previously, wax printing was considered an ideal PAD fabrication method, but given that wax printers are no longer commercially available, alternatives are needed. Here, we present one such alternative: the air-gap PAD. Air-gap PADs consist of hydrophilic paper test zones, separated by "air gaps" and affixed to a hydrophobic backing with double-sided adhesive. The primary appeal of this design is its compatibility with roll-to-roll equipment for large-scale manufacturing. In this study, we examine design considerations for air-gap PADs, compare the performance of wax-printed and air-gap PADs, and report on a pilot-scale roll-to-roll production run of air-gap PADs in partnership with a commercial test-strip manufacturer. Air-gap devices performed comparably to their wax-printed counterparts in Washburn flow experiments, a paper-based titration, and a 12-lane pharmaceutical screening device. Using roll-to-roll manufacturing, we produced 2700 feet of air-gap PADs for as little as $0.03 per PAD.
Collapse
Affiliation(s)
- Rachel M Roller
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556, USA.
| | - Angela Rea
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556, USA.
| | - Marya Lieberman
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556, USA.
| |
Collapse
|
19
|
Asci Erkocyigit B, Ozufuklar O, Yardim A, Guler Celik E, Timur S. Biomarker Detection in Early Diagnosis of Cancer: Recent Achievements in Point-of-Care Devices Based on Paper Microfluidics. BIOSENSORS 2023; 13:387. [PMID: 36979600 PMCID: PMC10046104 DOI: 10.3390/bios13030387] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 03/03/2023] [Accepted: 03/08/2023] [Indexed: 06/18/2023]
Abstract
Microfluidics is very crucial in lab-on-a-chip systems for carrying out operations in a large-scale laboratory environment on a single chip. Microfluidic systems are miniaturized devices in which the fluid behavior and control can be manipulated on a small platform, with surface forces on the platform being greater than volumetric forces depending on the test method used. In recent years, paper-based microfluidic analytical devices (μPADs) have been developed to be used in point-of-care (POC) technologies. μPADs have numerous advantages, including ease of use, low cost, capillary action liquid transfer without the need for power, the ability to store reagents in active form in the fiber network, and the capability to perform multiple tests using various measurement techniques. These benefits are critical in the advancement of paper-based microfluidics in the fields of disease diagnosis, drug application, and environment and food safety. Cancer is one of the most critical diseases for early detection all around the world. Detecting cancer-specific biomarkers provides significant data for both early diagnosis and controlling the disease progression. μPADs for cancer biomarker detection hold great promise for improving cure rates, quality of life, and minimizing treatment costs. Although various types of bioanalytical platforms are available for the detection of cancer biomarkers, there are limited studies and critical reviews on paper-based microfluidic platforms in the literature. Hence, this article aims to draw attention to these gaps in the literature as well as the features that future platforms should have.
Collapse
Affiliation(s)
- Bilge Asci Erkocyigit
- Department of Biotechnology, Institute of Natural Sciences, Ege University, Izmir 35100, Turkey
| | - Ozge Ozufuklar
- Department of Biotechnology, Institute of Natural Sciences, Ege University, Izmir 35100, Turkey
| | - Aysenur Yardim
- Department of Bioengineering, Institute of Natural Sciences, Ege University, Izmir 35100, Turkey
| | - Emine Guler Celik
- Department of Bioengineering, Faculty of Engineering, Ege University, Izmir 35100, Turkey
| | - Suna Timur
- Department of Biochemistry, Faculty of Science, Ege University, Izmir 35100, Turkey
- Central Research Test and Analysis Laboratory Application, Research Center, Ege University, Izmir 35100, Turkey
| |
Collapse
|
20
|
Holman JB, Shi Z, Fadahunsi AA, Li C, Ding W. Advances on microfluidic paper-based electroanalytical devices. Biotechnol Adv 2023; 63:108093. [PMID: 36603801 DOI: 10.1016/j.biotechadv.2022.108093] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 12/30/2022] [Accepted: 12/30/2022] [Indexed: 01/03/2023]
Abstract
Since the inception of the first electrochemical devices on paper substrates, many different reports of microfluidic paper-based electroanalytical devices (μPEDs), innovative hydrophobic barriers and electrode fabrication processes have allowed the incorporation of diverse materials, resulting in different applications and a boost in performance. These advancements have led to the creation of paper-based devices with comparable performance to many standard conventional devices, with the added benefits of pumpless fluidic transport, component separation and reagent storage that can be exploited to automate and handle sample preprocessing. Herein, we review μPEDs, summarize the characteristics and functionalities of μPEDs, such as separation, fluid flow control and storage, and outline the conventional and emerging fabrication and modification approaches for μPEDs. We also examine the recent application of μPEDs in biomedicine, the environment, and food and water safety, as well as some limitations and challenges that must be addressed.
Collapse
Affiliation(s)
- Joseph Benjamin Holman
- School of Information Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Zhengdi Shi
- School of Information Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Adeola A Fadahunsi
- School of Information Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Chengpan Li
- School of Information Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China.
| | - Weiping Ding
- Department of Oncology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui 230001, China.
| |
Collapse
|
21
|
Fernández-Ramos MD, Bolaños-Bañuelos M, Capitán-Vallvey LF. Point-of-care assay platform for uric acid, urea, and triglycerides with a microfluidic paper device (μPAD) controlled by stimulus-sensitive valves. Talanta 2023; 254:124189. [PMID: 36525868 DOI: 10.1016/j.talanta.2022.124189] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 12/04/2022] [Accepted: 12/08/2022] [Indexed: 12/14/2022]
Abstract
A microfluidic biosensor paper-based analytical device, or μPAD, was developed as a point-of-care assay platform for the simultaneous determination of three clinically important markers: uric acid, urea, and triglycerides. To achieve a simultaneous determination, thermosensitive valves based on N-isopropylacrylamide polymers controlled the flow of fluid in the μPAD. The evaluation of the analytical characteristics of the μPAD was done using a photographic camera at room temperature. The detection limits were 4.5·10-5, 2.5·10-3, and 1.5·10-3 mg mL-1, for uric acid, urea, and triglycerides, respectively, and the precision expressed as relative standard deviation (% RSD) 3.2, 1.2, and 1.6%. The obtained μPAD devices were validated with real human plasma samples, demonstrating high accuracy and precision. Multiple analyte point-of-care tests such as those developed here have excellent characteristics, being easy to manufacture, cost-effective, easy to use, and highly sensitive.
Collapse
Affiliation(s)
- M D Fernández-Ramos
- ECsens. Department of Analytical Chemistry, University of Granada, Granada, 18071, Spain; Unit of Excellence in Chemistry Applied to Biomedicine and the Environment of the University of Granada, Spain.
| | - M Bolaños-Bañuelos
- ECsens. Department of Analytical Chemistry, University of Granada, Granada, 18071, Spain
| | - L F Capitán-Vallvey
- ECsens. Department of Analytical Chemistry, University of Granada, Granada, 18071, Spain; Unit of Excellence in Chemistry Applied to Biomedicine and the Environment of the University of Granada, Spain
| |
Collapse
|
22
|
Shigemori H, Maejima K, Shibata H, Hiruta Y, Citterio D. Evaluation of cellophane as platform for colorimetric assays on microfluidic analytical devices. Mikrochim Acta 2023; 190:48. [PMID: 36622479 DOI: 10.1007/s00604-022-05622-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 12/14/2022] [Indexed: 01/10/2023]
Abstract
Due to their low cost, simplicity, and pump-free liquid transport properties, colorimetric assays on paper spots and microfluidic paper-based analytical devices (µPADs) are regarded as useful tools for point-of-care testing (POCT). However, for certain types of colorimetric assays, the "non-transparent" and "white" characters of paper can be a disadvantage. In this work, the possibilities of using cellophane as an alternative platform for colorimetric assays have been investigated. Cellophane is a low cost and easy-to-handle transparent film made of regenerated cellulose. Owing to its hydrophilic character, cellophane-based microfluidic channels fabricated through a print-cut-laminate approach enabled pump-free liquid transport into multiple detection areas, similar to µPADs. In addition, the water absorption characteristics of cellophane allowed the stable immobilization of water-soluble colorimetric indicators without any surface modification or additional reagents. The transparency of cellophane provides possibilities for simple background coloring of the substrates, increasing the dynamic signal range for hue-based colorimetric assays, as demonstrated for two model assays targeting H2O2 (46-fold increase) and creatinine (3.6-fold increase). Finally, a turbidity detection-based protein assay was realized on black background cellophane spots. The lowest limits of detection achieved with the cellophane-based devices were calculated as 7 µM for H2O2, 2.7 mg dL-1 for creatinine, and 3.5 mg dL-1 for protein (human serum albumin).
Collapse
Affiliation(s)
- Hiroki Shigemori
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-Ku, Yokohama, Kanagawa, 223-8522, Japan.,AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory (PhotoBIO-OIL), National Institute of Advanced Industrial Science and Technology (AIST), Photonics Center Osaka University, 2-1 Yamada-Oka, Suita, Osaka, 565-0871, Japan.,Graduate School of Human Development and Environment, Kobe University, 3-11 Tsurukabuto, Nada-Ku, Kobe, Hyogo, 657-0011, Japan
| | - Kento Maejima
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-Ku, Yokohama, Kanagawa, 223-8522, Japan
| | - Hiroyuki Shibata
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-Ku, Yokohama, Kanagawa, 223-8522, Japan
| | - Yuki Hiruta
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-Ku, Yokohama, Kanagawa, 223-8522, Japan
| | - Daniel Citterio
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-Ku, Yokohama, Kanagawa, 223-8522, Japan.
| |
Collapse
|
23
|
Syms RRA, Wright S. Paper-based evaporation concentrators: Comparison of linear and radial geometries. BIOMICROFLUIDICS 2023; 17:014102. [PMID: 36619875 PMCID: PMC9815885 DOI: 10.1063/5.0129510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 12/13/2022] [Indexed: 06/17/2023]
Abstract
Paper-based evaporation concentrators with linear and radial geometries are compared. A new method of finding approximate analytic solutions of the advection-dispersion equation is proposed, based on the behavior of concentrators with infinite sources. Analytic approximations are compared with numerical solutions, and the advantage of radial concentration is highlighted: linear concentration rates scale with the square root of the Péclet number Pe while radial rates scale with Pe itself, leading to faster radial concentration beyond a critical value. Experiments are performed with Brilliant Blue FCF dye, using optical transmission and the Beer-Lambert law for quantitation. Dye concentrations are chosen for operation in the linear absorbance regime. Radial concentration is demonstrated under ambient conditions on filter paper disks with 60 mm diameter evaporation areas fed from a perimeter source, in a reverse of the well-known "coffee stain" experiment. Airflow enhanced concentration in strips and wedges is compared directly, using laser-patterned chromatography paper. The advantage of radial concentration is confirmed (and enhanced by diversion of concentrate to the corners of strips) and concentration factors greater than ∼ 500 (the dynamic range of measurement) are obtained in ∼2 h using 30 mm long columns.
Collapse
Affiliation(s)
- Richard R. A. Syms
- EEE Department, Imperial College London, Exhibition Road, London SW7 2AZ, United Kingdom
| | - Steven Wright
- EEE Department, Imperial College London, Exhibition Road, London SW7 2AZ, United Kingdom
| |
Collapse
|
24
|
Anushka, Bandopadhyay A, Das PK. Paper based microfluidic devices: a review of fabrication techniques and applications. THE EUROPEAN PHYSICAL JOURNAL. SPECIAL TOPICS 2022; 232:781-815. [PMID: 36532608 PMCID: PMC9743133 DOI: 10.1140/epjs/s11734-022-00727-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Accepted: 11/09/2022] [Indexed: 06/14/2023]
Abstract
A wide range of applications are possible with paper-based analytical devices, which are low priced, easy to fabricate and operate, and require no specialized equipment. Paper-based microfluidics offers the design of miniaturized POC devices to be applied in the health, environment, food, and energy sector employing the ASSURED (Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment free and Deliverable to end users) principle of WHO. Therefore, this field is growing very rapidly and ample research is being done. This review focuses on fabrication and detection techniques reported to date. Additionally, this review emphasises on the application of this technology in the area of medical diagnosis, energy generation, environmental monitoring, and food quality control. This review also presents the theoretical analysis of fluid flow in porous media for the efficient handling and control of fluids. The limitations of PAD have also been discussed with an emphasis to concern on the transformation of such devices from laboratory to the consumer.
Collapse
Affiliation(s)
- Anushka
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721302 India
| | - Aditya Bandopadhyay
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721302 India
| | - Prasanta Kumar Das
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721302 India
| |
Collapse
|
25
|
Ma P, Wang S, Wang J, Wang Y, Dong Y, Li S, Su H, Chen P, Feng X, Li Y, Du W, Liu BF. Rapid Assembly of Cellulose Microfibers into Translucent and Flexible Microfluidic Paper-Based Analytical Devices via Wettability Patterning. Anal Chem 2022; 94:13332-13341. [PMID: 36121740 DOI: 10.1021/acs.analchem.2c01424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Microfluidic paper-based analytical devices (μPADs) are emerging as powerful analytical platforms in clinical diagnostics, food safety, and environmental protection because of their low cost and favorable substrate properties for biosensing. However, the existing top-down fabrication methods of paper-based chips suffer from low resolution (>200 μm). Additionally, papers have limitations in their physical properties (e.g., thickness, transmittance, and mechanical flexibility). Here, we demonstrate a bottom-up approach for the rapid fabrication of heterogeneously controlled paper-based chip arrays. We simply print a wax-patterned microchip with wettability contrasts, enabling automatic and selective assembly of cellulose microfibers to construct predefined paper-based microchip arrays with controllable thickness. This paper-based microchip printing technology is feasible for various substrate materials ranging from inorganic glass to organic polymers, providing a versatile platform for the full range of applications including transparent devices and flexible health monitoring. Our bottom-up printing technology using cellulose microfibers as the starting material provides a lateral resolution down to 42 ± 3 μm and achieves the narrowest channel barrier down to 33 ± 2 μm. As a proof-of-concept demonstration, a flexible paper-based glucose monitor is built for human health care, requiring only 0.3 μL of sample for testing.
Collapse
Affiliation(s)
- Peng Ma
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Shanshan Wang
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China.,BGI-Shenzhen, Shenzhen 518083, China
| | - Jie Wang
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Yu Wang
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Yue Dong
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Shunji Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Huiying Su
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China.,School of Biological Engineering, Huainan Normal University, Huainan, Anhui 232038, China
| | - Peng Chen
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Xiaojun Feng
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Yiwei Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Wei Du
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Bi-Feng Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
26
|
Kumawat N, Soman SS, Vijayavenkataraman S, Kumar S. Rapid and inexpensive process to fabricate paper based microfluidic devices using a cut and heat plastic lamination process. LAB ON A CHIP 2022; 22:3377-3389. [PMID: 35801817 DOI: 10.1039/d2lc00452f] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Microfluidic paper-based analytical devices (microPADs) are emerging as simple-to-use, low-cost point-of-care testing platforms. Such devices are mostly fabricated at present by creating hydrophobic barriers using wax or photoresist patterning on porous paper sheets. Even though devices fabricated using these methods are used and tested with a wide variety of analytes, still they pose many serious practical limitations for low-cost automated mass fabrication for their widespread applicability. We present an affordable and simple two-step process - cut and heat (CH-microPADs) - for the selective fabrication of hydrophilic channels and reservoirs on a wide variety of porous media such as tissue/printing/filter paper and cloth types, such as cotton and polyester, by a lamination process. The technique presents many advantages as compared to existing commonly used methods. The devices possess excellent mechanical strength against bending, folding and twisting, making them virtually unbreakable. They are structurally flexible and show good chemical resistance to various solvents, acids and bases, presenting widespread applicability in areas such as clinical diagnostics, biological sensing applications, food processing, and the chemical industry. Fabricated paper media 96 well-plate CH-microPAD configurations were tested for cell culture applications using mice embryonic fibroblasts and detection of proteins and enzymes using ELISA. With a simple two-step process and minimal human intervention, the technique presents a promising step towards mass fabrication of inexpensive disposable diagnostic devices for both resource-limited and developed regions.
Collapse
Affiliation(s)
- Nityanand Kumawat
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, P.O. Box 129188, United Arab Emirates.
| | - Soja Saghar Soman
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, P.O. Box 129188, United Arab Emirates.
| | - Sanjairaj Vijayavenkataraman
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, P.O. Box 129188, United Arab Emirates.
- Department of Mechanical Engineering, New York University, Brooklyn, NY 11201, USA
| | - Sunil Kumar
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, P.O. Box 129188, United Arab Emirates.
- Department of Mechanical Engineering, New York University, Brooklyn, NY 11201, USA
| |
Collapse
|
27
|
Wang R, Liu W, Wang Q, Lu Y. A paper-analytical device for detecting bisphenol-A in foods. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2982-2988. [PMID: 35916041 DOI: 10.1039/d2ay00720g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Bisphenol A (BPA) is a plastic monomer that can leach into food and cause adverse health effects with long-term exposure. In this study, we developed simple paper-analytical devices (PADs) for detecting BPA in food. The PADs were designed with hydrophilic and hydrophobic areas via wax printing. The hydrophilic areas were designed as a detection zone and modified with carboxymethyl cellulose (CMC) for the immobilisation of BPA-bovine serum albumin (BSA). The monoclonal antibodies against BPA were generated and modified with quantum dots (QDs) to synthesise QD-antibody (QD-Ab) probes. Detection conditions of the assay were optimized, with results of 0.1 μg of BPA-BSA and 30-fold diluted QD-Ab probes. The detection limit was 0.098 μg L-1 using ImageJ analysis. Samples of drinking water, green tea beverage and peanut cooking oil were selected to conduct the matrix effect study. The recovery rates of BPA in different samples ranged from 78.77% to 118.96%, proving that the PADs were a simple and sensitive detection method for easy, low-cost analysis of real food samples.
Collapse
Affiliation(s)
- Rui Wang
- State Key Laboratory for Food Nutrition and Safety, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin, 300457, China.
| | - Wentao Liu
- State Key Laboratory for Food Nutrition and Safety, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin, 300457, China.
| | - Qian Wang
- State Key Laboratory for Food Nutrition and Safety, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin, 300457, China.
| | - Yang Lu
- State Key Laboratory for Food Nutrition and Safety, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin, 300457, China.
| |
Collapse
|
28
|
Patari S, Datta P, Mahapatra PS. 3D Paper-based milk adulteration detection device. Sci Rep 2022; 12:13657. [PMID: 35953582 PMCID: PMC9372070 DOI: 10.1038/s41598-022-17851-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 08/02/2022] [Indexed: 11/22/2022] Open
Abstract
Milk adulteration is a common problem in developing countries, and it can lead to fatal diseases in humans. Despite several studies to identify different adulterants in milk samples, the effects of multiple adulterants remain unexplored. In this work, a three-dimensional (3D) paper-based microfluidic device is designed and fabricated to simultaneously detect multiple chemical adulterants in milk. This device comprises a top cover, a bottom cover, and a middle layer composed of transportation and a detection zone. By making cuts on the middle layer's support, the device's flow path is characterised by optimum and uniform velocity. For the first time, seven adulterants (urea, detergents, soap, starch, hydrogen peroxide, sodium-hydrogen-carbonate, and salt) are detected in the milk sample simultaneously with specificity evaluation and detailed color interference analysis. Only 1-2 mL of sample volume is required to detect 7 adulterants at one time. We have used only 10 [Formula: see text]L of the reagent's volume for the colorimetric reaction and found the results within a few seconds. Observation reveals that the limit of detection (LOD) of the adulterants lies in the range between [Formula: see text] (vol./vol.) to [Formula: see text] (vol./vol.) using the colorimetric detection technique. The unknown quantity of the added adulterants is measured using the calibration curves obtained from the experiments results. The repeatability and reproducibility of the process, sensitivity, and the linear range of detection of the calibration curves and the statistical study of the color intensity data are thoroughly analysed herein. In any resource-limited setting, this simple, portable, and user-friendly 3D microfluidic device is expected to be used for testing liquid foods before consumption.
Collapse
Affiliation(s)
- Subhashis Patari
- Micro Nano Bio-Fluids Group, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, 600036, India
| | - Priyankan Datta
- Micro Nano Bio-Fluids Group, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, 600036, India
| | - Pallab Sinha Mahapatra
- Micro Nano Bio-Fluids Group, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, 600036, India.
| |
Collapse
|
29
|
Sarabi MR, Yigci D, Alseed MM, Mathyk BA, Ata B, Halicigil C, Tasoglu S. Disposable Paper-Based Microfluidics for Fertility Testing. iScience 2022; 25:104986. [PMID: 36105592 PMCID: PMC9465368 DOI: 10.1016/j.isci.2022.104986] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Fifteen percent of couples of reproductive age suffer from infertility globally and the burden of infertility disproportionately impacts residents of developing countries. Assisted reproductive technologies (ARTs), including in vitro fertilization (IVF) and intracytoplasmic sperm injection (ICSI), have been successful in overcoming various reasons for infertility including borderline and severe male factor infertility which consists of 20%–30% of all infertile cases. Approximately half of male infertility cases stem from suboptimal sperm parameters. Therefore, healthy/normal sperm enrichment and sorting remains crucial in advancing reproductive medicine. Microfluidic technologies have emerged as promising tools to develop in-home rapid fertility tests and point-of-care (POC) diagnostic tools. Here, we review advancements in fabrication methods for paper-based microfluidic devices and their emerging fertility testing applications assessing sperm concentration, sperm motility, sperm DNA analysis, and other sperm functionalities, and provide a glimpse into future directions for paper-based fertility microfluidic systems. Paper-based technologies are emerging to develop in-home rapid fertility tests Fabrication methods for paper-based microfluidic devices are presented Emerging disposable paper-based fertility testing applications are reviewed
Collapse
Affiliation(s)
| | - Defne Yigci
- School of Medicine, Koç University, Istanbul, Türkiye 34450
| | - M. Munzer Alseed
- Boğaziçi Institute of Biomedical Engineering, Boğaziçi University, Istanbul, Türkiye 34684
| | - Begum Aydogan Mathyk
- Department of Obstetrics and Gynecology, HCA Healthcare, University of South Florida Morsani College of Medicine GME, Brandon Regional Hospital, Florida 33511, USA
| | - Baris Ata
- School of Medicine, Koç University, Istanbul, Türkiye 34450
- ART Fertility Clinics, Dubai, United Arab Emirates 337-1500
| | - Cihan Halicigil
- Yale School of Medicine, Yale University, Connecticut 06520, USA
| | - Savas Tasoglu
- School of Mechanical Engineering, Koç University, Istanbul, Türkiye 34450
- Boğaziçi Institute of Biomedical Engineering, Boğaziçi University, Istanbul, Türkiye 34684
- Koç University Translational Medicine Research Center (KUTTAM), Koç University, Istanbul, Türkiye 34450
- Koç University Arçelik Research Center for Creative Industries (KUAR), Koç University, Istanbul, Türkiye 34450
- Koç University Is Bank Artificial Intelligence Lab (KUIS AI Lab), Koç University, Istanbul, Türkiye 34450
- Corresponding author
| |
Collapse
|
30
|
Zhang T, Ding F, Yang Y, Zhao G, Zhang C, Wang R, Huang X. Research Progress and Future Trends of Microfluidic Paper-Based Analytical Devices in In-Vitro Diagnosis. BIOSENSORS 2022; 12:485. [PMID: 35884289 PMCID: PMC9313202 DOI: 10.3390/bios12070485] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 06/30/2022] [Accepted: 07/01/2022] [Indexed: 12/14/2022]
Abstract
In vitro diagnosis (IVD) has become a hot topic in laboratory research and achievement transformation. However, due to the high cost, and time-consuming and complex operation of traditional technologies, some new technologies are being introduced into IVD, to solve the existing problems. As a result, IVD has begun to develop toward point-of-care testing (POCT), a subdivision field of IVD. The pandemic has made governments and health institutions realize the urgency of accelerating the development of POCT. Microfluidic paper-based analytical devices (μPADs), a low-cost, high-efficiency, and easy-to-operate detection platform, have played a significant role in advancing the development of IVD. μPADs are composed of paper as the core material, certain unique substances as reagents for processing the paper, and sensing devices, as auxiliary equipment. The published reviews on the same topic lack a comprehensive and systematic introduction to μPAD classification and research progress in IVD segmentation. In this paper, we first briefly introduce the origin of μPADs and their role in promoting IVD, in the introduction section. Then, processing and detection methods for μPADs are summarized, and the innovative achievements of μPADs in IVD are reviewed. Finally, we discuss and prospect the upgrade and improvement directions of μPADs, in terms of portability, sensitivity, and automation, to help researchers clarify the progress and overcome the difficulties in subsequent μPAD research.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Xiaowen Huang
- State Key Laboratory of Biobased Material and Green Papermaking, School of Bioengineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China; (T.Z.); (F.D.); (Y.Y.); (G.Z.); (C.Z.); (R.W.)
| |
Collapse
|
31
|
Beard JW, Murty S, Caulkins C, Strenk AR, Luta EP, Hunt SL, Yates MZ, Miller BL. Leveraging Arylboronic Acid - Cellulose Binding as a Versatile and Scalable Approach to Hydrophobic Patterning. ADVANCED MATERIALS TECHNOLOGIES 2022; 7:2101280. [PMID: 35935145 PMCID: PMC9355117 DOI: 10.1002/admt.202101280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Indexed: 06/15/2023]
Abstract
Paper-based analytical devices, or μPADs, have proven to be valuable bioanalytical tools for a broad range of applications. New methods for μPAD fabrication are needed, however, to facilitate their mass production at a competitive cost. To address this need, we report the use of a boronic acid-containing siloxane polymer (BorSilOx) for patterning hydrophobic barriers for μPADs. This material functions by covalently binding to hydroxyl groups in the paper substrate. It is compatible with inkjet printing or roll-to-roll (stamping) processes, as demonstrated here using three different deposition methods. BorSilOx is able to render a broad range of cellulosic materials (from paper towels to wood) hydrophobic, with contact angle measurements demonstrating superhydrophobicity in many cases. We further demonstrate the utility of the polymer in μPADs via assays for pH and glucose.
Collapse
Affiliation(s)
- Jeffrey W Beard
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
| | - Shannon Murty
- Department of Chemical Engineering, University of Rochester, Rochester, NY 14627, USA
| | - Christina Caulkins
- Department of Chemical Engineering, University of Rochester, Rochester, NY 14627, USA
| | - Amanda R Strenk
- Department of Chemical Engineering, University of Rochester, Rochester, NY 14627, USA
| | - Ethan P Luta
- Department of Dermatology, University of Rochester, Rochester, NY 14642
| | - Samuel L Hunt
- Department of Dermatology, University of Rochester, Rochester, NY 14642
| | - Matthew Z Yates
- Department of Chemical Engineering, University of Rochester, Rochester, NY 14627, USA
| | - Benjamin L Miller
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
| |
Collapse
|
32
|
Murray LP, Mace CR. Paper-Based Cytometer for the Detection and Enumeration of White Blood Cells According to Their Immunophenotype. Anal Chem 2022; 94:10443-10450. [PMID: 35696545 DOI: 10.1021/acs.analchem.2c01635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Total and differential white blood cell (WBC) counts are vital metrics used routinely by clinicians to aid in the identification of diseases. However, the equipment necessary to perform WBC counts restricts their operation to centralized laboratories, greatly limiting their accessibility. Established solutions for the development of point-of-care assays, namely lateral flow tests and paper-based microfluidic devices, are inherently limited in their ability to support the detection of WBCs─the pore sizes of materials used to fabricate these devices (e.g., membranes or chromatography papers) do not permit passive WBC transport via wicking. Herein, we identify a material capable of the unimpeded transport of WBCs in both lateral and vertical directions: a coffee filter. Through in situ labeling with an enzyme-labeled affinity reagent, our paper-based cytometer detects WBCs according to their immunophenotype. Using two cultured leukocyte lines (Jurkat D1.1 T cells and MAVER-1 B cells), we demonstrate the specific, colorimetric enumeration of each target cell population across the expected physiological range for total lymphocytes, 1000-4000 cells μL-1. Additionally, we highlight a potential application of this type of device as a screening tool for detecting abnormal cell counts outside the normal physiological range and in subclasses of cell types, which could aid in the identification of certain diseases (e.g., CD4+ T lymphocytes, an important biomarker for HIV disease/AIDS). These results pave the way for a new class of paper-based devices─those capable of controlled white blood cell transport, labeling, capture, and detection─thus expanding the opportunities for low-cost, point-of-care cytometers.
Collapse
Affiliation(s)
- Lara P Murray
- Department of Chemistry, Laboratory for Living Devices, Tufts University, Medford, Massachusetts 02155, United States
| | - Charles R Mace
- Department of Chemistry, Laboratory for Living Devices, Tufts University, Medford, Massachusetts 02155, United States
| |
Collapse
|
33
|
Recent advances in optical biosensors for specific detection of E. coli bacteria in food and water. Food Control 2022. [DOI: 10.1016/j.foodcont.2022.108822] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
34
|
Jackson S, Lee S, Badu-Tawiah AK. Automated Immunoassay Performed on a 3D Microfluidic Paper-Based Device for Malaria Detection by Ambient Mass Spectrometry. Anal Chem 2022; 94:5132-5139. [PMID: 35293204 DOI: 10.1021/acs.analchem.1c05530] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Microfluidic paper-based analytical devices (μPADs) are emerging as a prominent platform for disease detection, specifically in developing countries. This paper device offer simplicity and affordability not typically seen in centralized laboratory settings. However, detection limits in μPADs are inadequate and often require test results to be read within a specific time interval to ensure accuracy. To overcome these challenges, we are developing an on-chip mass spectrometry (MS) detection strategy for immunoassays performed on paper substrates. Herein, we present our initial results from a proof-of-concept study toward the development of μPADs capable of storing immunoassay reagents within the confinements of the 3D device, automatic splitting of biofluid into four individual test zones, immuno-capture of the disease biomarker, and on-chip MS detection of the captured species. The reported study encourages the development of point-of-care and direct-to-customer testing using disposable μPADs to collect samples, followed by sensitive analysis using portable MSs. We demonstrate this capability using malaria Plasmodium falciparum histidine-rich protein 2 (PfHRP2) antigen detection.
Collapse
Affiliation(s)
- Sierra Jackson
- Department of Chemistry and Biochemistry, The Ohio State University, 100 W. 18th Avenue, Columbus, Ohio 43210, United States
| | - Suji Lee
- Department of Chemistry and Biochemistry, The Ohio State University, 100 W. 18th Avenue, Columbus, Ohio 43210, United States
| | - Abraham K Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, 100 W. 18th Avenue, Columbus, Ohio 43210, United States
| |
Collapse
|
35
|
Abstract
Printing technology promises a viable solution for the low-cost, rapid, flexible, and mass fabrication of biosensors. Among the vast number of printing techniques, screen printing and inkjet printing have been widely adopted for the fabrication of biosensors. Screen printing provides ease of operation and rapid processing; however, it is bound by the effects of viscous inks, high material waste, and the requirement for masks, to name a few. Inkjet printing, on the other hand, is well suited for mass fabrication that takes advantage of computer-aided design software for pattern modifications. Furthermore, being drop-on-demand, it prevents precious material waste and offers high-resolution patterning. To exploit the features of inkjet printing technology, scientists have been keen to use it for the development of biosensors since 1988. A vast number of fully and partially inkjet-printed biosensors have been developed ever since. This study presents a short introduction on the printing technology used for biosensor fabrication in general, and a brief review of the recent reports related to virus, enzymatic, and non-enzymatic biosensor fabrication, via inkjet printing technology in particular.
Collapse
|
36
|
Shin J, Kasama T, Miyake R. Development of cellulosic material-based microchannel device capable of fluorescence immunoassay of microsamples. Anal Bioanal Chem 2022; 414:3419-3428. [PMID: 35169907 DOI: 10.1007/s00216-022-03963-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 02/02/2022] [Accepted: 02/04/2022] [Indexed: 11/28/2022]
Abstract
Microfluidic immunoassay devices are a promising technology that can quickly detect biomarkers with high sensitivity. Recently, many studies implementing this technology on paper substrates have been proposed for improving cost and user-friendliness. However, these studies have identified problems with the large volume of sample required, low sensitivity, and a lack of quantitative accuracy and precision. In this paper, we report a novel structure implemented as a cellulosic material-based microchannel device capable of quantitative immunoassay using small sample volumes. We fabricated microfluidic channels between a transparent cellophane film and water-resistant paper to facilitate loading of small-volume samples and reagents, with a 40-μm-wide immunoreaction matrix constructed in the center of the microchannel using highly precise photolithography. A fluorescence sandwich immunoassay for C-reactive protein (CRP) was successfully implemented that required only a 1-μL sample volume and a 20-min reaction time. We confirmed that the limit of detection of the device was 10-20 ng/mL with a coefficient of variation under 5.6%, which is a performance level comparable to conventional plastic-based human CRP enzyme-linked immunosorbent assay (ELISA) kits. We expect that such devices will lead to the elimination of large amounts of medical waste from the use of ubiquitous diagnostics, a result that is consistent with environmental sustainability goals.
Collapse
Affiliation(s)
- Jungchan Shin
- Department of Bioengineering, Graduate School of Engineering, The University of Tokyo, Tokyo, 113-8654, Japan
| | - Toshihiro Kasama
- Department of Bioengineering, Graduate School of Engineering, The University of Tokyo, Tokyo, 113-8654, Japan
| | - Ryo Miyake
- Department of Bioengineering, Graduate School of Engineering, The University of Tokyo, Tokyo, 113-8654, Japan.
| |
Collapse
|
37
|
Heinsohn NK, Niedl RR, Anielski A, Lisdat F, Beta C. Electrophoretic µPAD for Purification and Analysis of DNA Samples. BIOSENSORS 2022; 12:62. [PMID: 35200323 PMCID: PMC8869226 DOI: 10.3390/bios12020062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 01/13/2022] [Accepted: 01/17/2022] [Indexed: 11/16/2022]
Abstract
In this work, the fabrication and characterization of a simple, inexpensive, and effective microfluidic paper analytic device (µPAD) for monitoring DNA samples is reported. The glass microfiber-based chip has been fabricated by a new wax-based transfer-printing technique and an electrode printing process. It is capable of moving DNA effectively in a time-dependent fashion. The nucleic acid sample is not damaged by this process and is accumulated in front of the anode, but not directly on the electrode. Thus, further DNA processing is feasible. The system allows the DNA to be purified by separating it from other components in sample mixtures such as proteins. Furthermore, it is demonstrated that DNA can be moved through several layers of the glass fiber material. This proof of concept will provide the basis for the development of rapid test systems, e.g., for the detection of pathogens in water samples.
Collapse
Affiliation(s)
- Natascha Katharina Heinsohn
- InventicsDx GmbH, Magnusstrasse 11, 12489 Berlin, Germany; (R.R.N.); (A.A.)
- Biological Physics, Institute of Physics and Astronomy, University of Potsdam, Karl-Liebknecht-Strasse 24/25, 14476 Potsdam, Germany
| | | | - Alexander Anielski
- InventicsDx GmbH, Magnusstrasse 11, 12489 Berlin, Germany; (R.R.N.); (A.A.)
| | - Fred Lisdat
- Biosystems Technology, Institute of Life Sciences and Biomedical Technologies, Technical University of Applied Sciences, Hochschulring 1, 15745 Wildau, Germany
| | - Carsten Beta
- Biological Physics, Institute of Physics and Astronomy, University of Potsdam, Karl-Liebknecht-Strasse 24/25, 14476 Potsdam, Germany
| |
Collapse
|
38
|
Resmi PE, Suneesh PV, Ramachandran T, Babu TGS. Paper based micro/nanofluidics devices for biomedical applications. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 186:159-190. [PMID: 35033283 DOI: 10.1016/bs.pmbts.2021.07.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
This chapter details the significance, fabrication and biomedical applications of paper-based microfluidic devices. The first part of the chapter describes the importance of paper diagnostic devices, highlighting pretreatment, dipsticks, lateral flow assays, and microPADs. Various methods followed for the fabrication of the paper analytical devices are discussed in the second part. The last part is about some of the important biomedical applications of paper analytical devices. Finally, the challenges and research gaps in the paper microfluidics for biomedical applications are presented.
Collapse
Affiliation(s)
- P E Resmi
- Amrita Biosensor Research Lab, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India
| | - P V Suneesh
- Amrita Biosensor Research Lab, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India; Department of Sciences, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India
| | - T Ramachandran
- Department of Sciences, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India
| | - T G Satheesh Babu
- Amrita Biosensor Research Lab, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India; Department of Sciences, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India.
| |
Collapse
|
39
|
Sinha A, Basu M, Chandna P. Paper based microfluidics: A forecast toward the most affordable and rapid point-of-care devices. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 186:109-158. [PMID: 35033281 DOI: 10.1016/bs.pmbts.2021.07.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The microfluidic industry has evolved through years with acquired scientific knowledge from different, and already developed industries. Consequently, a wide range of materials like silicon from the electronic industry to all the way, silicone, from the chemical engineering industry, has been spotted to solve similar challenges. Although a typical microfluidic chip, fabricated from glass or polymer substrates offers definite benefits, however, paper-based microfluidic analytical devices (μPADs) possess numerous special benefits for practical implementation at a lower price. Owing to these features, in recent years, paper microfluidics has drawn immense interest from researchers in industry and academia alike. These devices have wider applications with advantages like lower cost, speedy detection, user-easiness, biocompatibility, sensitivity, and specificity etc. when compared to other microfluidic devices. Therefore, these sensitive but affordable devices fit themselves into point-of-care (POC) testing with features in demand like natural disposability, situational flexibility, and the capability to store and analyze the target at the point of requirement. Gradually, advancements in fabrication technologies, assay development techniques, and improved packaging capabilities, have contributed significantly to the real-time identification and health investigation through paper microfluidics; however, the growth has not been limited to the biomedical field; industries like electronics, energy storage and many more have expanded substantially. Here, we represent an overall state of the paper-based microfluidic technology by covering the fundamentals, working principles, different fabrication procedures, applications for various needs and then to make things more practical, the real-life scenario and practical challenges involved in launching a device into the market have been revealed. To conclude, recent contribution of μPADs in the 2020 pandemic and potential future possibilities have been reviewed.
Collapse
|
40
|
Carvalho BG, Ceccato BT, Michelon M, Han SW, de la Torre LG. Advanced Microfluidic Technologies for Lipid Nano-Microsystems from Synthesis to Biological Application. Pharmaceutics 2022; 14:141. [PMID: 35057037 PMCID: PMC8781930 DOI: 10.3390/pharmaceutics14010141] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Revised: 12/23/2021] [Accepted: 12/30/2021] [Indexed: 12/17/2022] Open
Abstract
Microfluidics is an emerging technology that can be employed as a powerful tool for designing lipid nano-microsized structures for biological applications. Those lipid structures can be used as carrying vehicles for a wide range of drugs and genetic materials. Microfluidic technology also allows the design of sustainable processes with less financial demand, while it can be scaled up using parallelization to increase production. From this perspective, this article reviews the recent advances in the synthesis of lipid-based nanostructures through microfluidics (liposomes, lipoplexes, lipid nanoparticles, core-shell nanoparticles, and biomimetic nanovesicles). Besides that, this review describes the recent microfluidic approaches to produce lipid micro-sized structures as giant unilamellar vesicles. New strategies are also described for the controlled release of the lipid payloads using microgels and droplet-based microfluidics. To address the importance of microfluidics for lipid-nanoparticle screening, an overview of how microfluidic systems can be used to mimic the cellular environment is also presented. Future trends and perspectives in designing novel nano and micro scales are also discussed herein.
Collapse
Affiliation(s)
- Bruna G. Carvalho
- Department of Material and Bioprocess Engineering, School of Chemical Engineering, University of Campinas (UNICAMP), Campinas 13083-852, Brazil; (B.G.C.); (B.T.C.)
| | - Bruno T. Ceccato
- Department of Material and Bioprocess Engineering, School of Chemical Engineering, University of Campinas (UNICAMP), Campinas 13083-852, Brazil; (B.G.C.); (B.T.C.)
| | - Mariano Michelon
- School of Chemical and Food Engineering, Federal University of Rio Grande (FURG), Rio Grande 96203-900, Brazil;
| | - Sang W. Han
- Center for Cell Therapy and Molecular, Department of Biophysics, Federal University of São Paulo (UNIFESP), São Paulo 04044-010, Brazil;
| | - Lucimara G. de la Torre
- Department of Material and Bioprocess Engineering, School of Chemical Engineering, University of Campinas (UNICAMP), Campinas 13083-852, Brazil; (B.G.C.); (B.T.C.)
| |
Collapse
|
41
|
Equipment-free and visual detection of Pb2+ ion based on curcumin-modified bacterial cellulose nanofiber. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2022. [DOI: 10.1007/s13738-021-02305-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
42
|
Rapid, Simple and Inexpensive Fabrication of Paper-Based Analytical Devices by Parafilm ® Hot Pressing. MICROMACHINES 2021; 13:mi13010048. [PMID: 35056213 PMCID: PMC8780184 DOI: 10.3390/mi13010048] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 12/23/2021] [Accepted: 12/27/2021] [Indexed: 11/28/2022]
Abstract
Paper-based analytical devices have been substantially developed in recent decades. Many fabrication techniques for paper-based analytical devices have been demonstrated and reported. Herein, we report a relatively rapid, simple, and inexpensive method for fabricating paper-based analytical devices using parafilm hot pressing. We studied and optimized the effect of the key fabrication parameters, namely pressure, temperature, and pressing time. We discerned the optimal conditions, including a pressure of 3.8 MPa, temperature of 80 °C, and 3 min of pressing time, with the smallest hydrophobic barrier size (821 µm) being governed by laminate mask and parafilm dispersal from pressure and heat. Physical and biochemical properties were evaluated to substantiate the paper functionality for analytical devices. The wicking speed in the fabricated paper strips was slightly lower than that of non-processed paper, resulting from a reduced paper pore size after hot pressing. A colorimetric immunological assay was performed to demonstrate the protein binding capacity of the paper-based device after exposure to pressure and heat from the fabrication. Moreover, mixing in a two-dimensional paper-based device and flowing in a three-dimensional counterpart were thoroughly investigated, demonstrating that the paper devices from this fabrication process are potentially applicable as analytical devices for biomolecule detection. Fast, easy, and inexpensive parafilm hot press fabrication presents an opportunity for researchers to develop paper-based analytical devices in resource-limited environments.
Collapse
|
43
|
Selvakumar B, Kathiravan A. Sensory materials for microfluidic paper based analytical devices - A review. Talanta 2021; 235:122733. [PMID: 34517601 DOI: 10.1016/j.talanta.2021.122733] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 07/18/2021] [Accepted: 07/23/2021] [Indexed: 11/17/2022]
Abstract
The microfluidic paper-based analytical devices (μPADs) have grown-up swiftly over the decade due to its low cost, simple fabrication procedure, resource-limitedness, non-toxicity and their environmentally benign nature. The μPADs, also identified as point-of-care devices or health care devices have successfully applied in several fields such as diagnostics, biological, food safety, environmental, electrochemical and most importantly colorimetric/fluorimetric sensors, owing to the attractive passive motions of analyte without any external forces. In recent years, a large number of colorimetric and fluorimetric probes have been reported that can selectively recognize the analytes in μPADs. However, there is no organized review on its structure-activity relationship. In this review, we have focused to summarize the colorimetric and fluorimetric probes utilized in μPADs. This review discuss about the relationships between the structure and functions of various probes as signaling units of the efficient μPADs. The probes including nanomaterials, nanozymes, polymers and organic molecules, their structural activity with regard to sensing performances along with their limit of detection are also discussed. This review is expected to assist readers for better understanding of the sensing mechanisms of various chemo and bio-probes utilized in μPADs, as well as promote their advancement in the field. On the other hand, this review also helps the researchers for enhancement of μPADs and paves way for synergistic application of existing molecular probes as an effective diagnostic tool for the worldwide pandemic novel corona virus COVID-19.
Collapse
Affiliation(s)
- Bhavadharini Selvakumar
- Department of Chemistry, Vel Tech Rangarajan Dr Sagunthala R & D Institute of Science and Technology, Avadi, Chennai, 600 062, Tamil Nadu, India
| | - Arunkumar Kathiravan
- Department of Chemistry, Vel Tech Rangarajan Dr Sagunthala R & D Institute of Science and Technology, Avadi, Chennai, 600 062, Tamil Nadu, India.
| |
Collapse
|
44
|
Wu S, Wu M, Wang G, Chen TH. Visual quantitation of silver contamination in fresh water via accumulative length of microparticles in capillary-driven microfluidic devices. Talanta 2021; 235:122707. [PMID: 34517580 DOI: 10.1016/j.talanta.2021.122707] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 07/06/2021] [Accepted: 07/08/2021] [Indexed: 10/20/2022]
Abstract
Silver is a heavy metal commonly used as bacteriostatic agents or disinfectants. However, excess amount of silver ion (Ag+) could lead to adverse biological effects on human health. To monitor silver ions in environmental samples, we report a visual quantitative method for analyzing the trace amount of Ag+. A sliver-specific RNA-cleaving DNAzyme Ag10C firstly makes the connection between magnetic microparticles (MMPs) and polystyrene microparticles (PMPs) forming a complex as "MMPs-Ag10C-PMPs". When Ag+ is present, the Ag10C is cleaved, resulting in an increase of free PMPs. By dropping 3 μL of reacted particle solution to a capillary-driven microfluidic chip, MMPs and MMPs-Ag10C-PMPs are removed by a magnetic separator during the flow, while free PMPs can continue flowing until being trapped and accumulating at a particle dam with a narrow nozzle. The accumulation length of PMPs linearly increases with the increment of Ag+ concentrations in the range of 0-10 μM, and readable by the naked eye. We have achieved a limit of detection (LOD) down to 453.7 nM, which is significantly lower than the maximum contaminant level of 926 nM set by World Health Organization (WHO). More importantly, after validating the high selectivity against other metal ions and stable performance in different pH and water hardness, we demonstrate recovery rate >96.8% for tests of multiple fresh water sources, manifesting the feasibility in practical detection in real water samples.
Collapse
Affiliation(s)
- Siying Wu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong
| | - Minghui Wu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong
| | - Gaobo Wang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong
| | - Ting-Hsuan Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong.
| |
Collapse
|
45
|
Solin K, Borghei M, Imani M, Kämäräinen T, Kiri K, Mäkelä T, Khakalo A, Orelma H, Gane PAC, Rojas OJ. Bicomponent Cellulose Fibrils and Minerals Afford Wicking Channels Stencil-Printed on Paper for Rapid and Reliable Fluidic Platforms. ACS APPLIED POLYMER MATERIALS 2021; 3:5536-5546. [PMID: 34796333 PMCID: PMC8593863 DOI: 10.1021/acsapm.1c00856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Accepted: 09/23/2021] [Indexed: 05/14/2023]
Abstract
Flexible and easy-to-use microfluidic systems are suitable options for point-of-care diagnostics. Here, we investigate liquid transport in fluidic channels produced by stencil printing on flexible substrates as a reproducible and scalable option for diagnostics and paper-based sensing. Optimal printability and flow profiles were obtained by combining minerals with cellulose fibrils of two different characteristic dimensions, in the nano- and microscales, forming channels with ideal wettability. Biomolecular ligands were easily added by inkjet printing on the channels, which were tested for the simultaneous detection of glucose and proteins. Accurate determination of clinically relevant concentrations was possible from linear calibration, confirming the potential of the introduced paper-based diagnostics. The results indicate the promise of simple but reliable fluidic channels for drug and chemical analyses, chromatographic separation, and quality control.
Collapse
Affiliation(s)
- Katariina Solin
- Department
of Bioproducts and Biosystems, School of Chemical Engineering, Aalto University, Vuorimiehentie 1, FI-00076 Espoo, Finland
- VTT
Technical Research Centre of Finland Ltd., Functional Cellulose, Tietotie 4E, FI-02044 Espoo, Finland
| | - Maryam Borghei
- Department
of Bioproducts and Biosystems, School of Chemical Engineering, Aalto University, Vuorimiehentie 1, FI-00076 Espoo, Finland
| | - Monireh Imani
- Department
of Bioproducts and Biosystems, School of Chemical Engineering, Aalto University, Vuorimiehentie 1, FI-00076 Espoo, Finland
| | - Tero Kämäräinen
- Department
of Bioproducts and Biosystems, School of Chemical Engineering, Aalto University, Vuorimiehentie 1, FI-00076 Espoo, Finland
| | - Kaisa Kiri
- VTT
Technical Research Centre of Finland Ltd., Micronova, Tietotie 3, FI-02150 Espoo, Finland
| | - Tapio Mäkelä
- VTT
Technical Research Centre of Finland Ltd., Micronova, Tietotie 3, FI-02150 Espoo, Finland
| | - Alexey Khakalo
- VTT
Technical Research Centre of Finland Ltd., Functional Cellulose, Tietotie 4E, FI-02044 Espoo, Finland
| | - Hannes Orelma
- VTT
Technical Research Centre of Finland Ltd., Functional Cellulose, Tietotie 4E, FI-02044 Espoo, Finland
| | - Patrick A. C. Gane
- Department
of Bioproducts and Biosystems, School of Chemical Engineering, Aalto University, Vuorimiehentie 1, FI-00076 Espoo, Finland
| | - Orlando J. Rojas
- Department
of Bioproducts and Biosystems, School of Chemical Engineering, Aalto University, Vuorimiehentie 1, FI-00076 Espoo, Finland
- The
Bioproducts Institute, Departments of Chemical and Biological Engineering,
Chemistry and Wood Science, University of
British Columbia, 2360 East Mall, Vancouver, BC V6T 1Z4, Canada
| |
Collapse
|
46
|
Designing of various biosensor devices for determination of apoptosis: A comprehensive review. Biochem Biophys Res Commun 2021; 578:42-62. [PMID: 34536828 DOI: 10.1016/j.bbrc.2021.08.089] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 08/29/2021] [Accepted: 08/29/2021] [Indexed: 12/30/2022]
Abstract
Apoptosis is a type of cell death caused by the occurrence of both pathological and physiological conditions triggered by ligation of death receptors outside the cell or triggered by DNA damage and/or cytoskeleton disruption. Timely monitoring of apoptosis can effectively help early diagnosis of related diseases and continuous assessment of the effectiveness of drugs. Detecting caspases, a protease family closely related to cellular apoptosis, and its identification as markers of apoptosis is a popular procedure. Biosensors are used for early diagnosis and play a very important role in preventing disease progression in various body sections. Recently, there has been a widespread increase in the desire to use materials made of paper (e.g. nitrocellulose membrane) for Point-of-Care (POC) testing systems since paper and paper-like materials are cheap, abundant and degradable. Microfluidic paper-based analytical devices (μPADs) are highly promising as they are cost-effective, easy to use, fast, precise and sustainable over time and under different environmental conditions. In this review, we focused our efforts on compiling the different approaches on identifying apoptosis pathway while giving brief information about apoptosis and biosensors. This review includes recent advantages in biosensing techniques to simply determine what happened in the cell life and which direction it would continue. As a conclusion, we believed that the review may help to researchers to compare/update the knowledge about diagnosis of the apoptosis pathway while reminding the basic definitions about the apoptosis and biosensor technologies.
Collapse
|
47
|
Tseng HY, Lizama JH, Shen YW, Chen CJ. The pursuit of further miniaturization of screen printed micro paper-based analytical devices utilizing controlled penetration towards optimized channel patterning. Sci Rep 2021; 11:21496. [PMID: 34728732 PMCID: PMC8563737 DOI: 10.1038/s41598-021-01048-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 10/20/2021] [Indexed: 12/17/2022] Open
Abstract
One of the main objectives of microfluidic paper-based analytical devices is to present solutions particularly, for applications in low-resource settings. Therefore, screen-printing appears to be an attractive fabrication technique in the field, due to its overall simplicity, affordability, and high-scalability potential. Conversely, the minimum feature size attained using screen-printing is still rather low, especially compared to other fabrication methods, mainly attributed to the over-penetration of hydrophobic agents, underneath defined patterns on masks, into the fiber matrix of paper substrates. In this work, we propose the use of the over-penetration to our advantage, whereby an appropriate combination of hydrophobic agent temperature and substrate thickness, allows for the proper control of channel patterning, rendering considerably higher resolutions than prior arts. The implementation of Xuan paper and nail oil as novel substrate and hydrophobic agent, respectively, is proposed in this work. Under optimum conditions of temperature and substrate thickness, the resolution of the screen-printing method was pushed up to 97.83 ± 16.34 μm of channel width with acceptable repeatability. It was also found that a trade-off exists between achieving considerably high channel resolutions and maintaining high levels of repeatability of the process. Lastly, miniaturized microfluidic channels were successfully patterned on pH strips for colorimetric pH measurement, demonstrating its advantage on negligible sample-volume consumption in nano-liter range during chemical measurement and minimal interference on manipulation of precious samples, which for the first time, is realized on screen-printed microfluidic paper-based analytical devices.
Collapse
Affiliation(s)
- Hsiu-Yang Tseng
- Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, 106, Taiwan.
| | - Jose H Lizama
- Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, 106, Taiwan
| | - Yi-Wei Shen
- Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, 106, Taiwan
| | - Chiu-Jen Chen
- Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, 106, Taiwan
| |
Collapse
|
48
|
Wang E, Guo Z, Tang R, Lo YH. Using airflow-driven, evaporative gradients to improve sensitivity and fluid control in colorimetric paper-based assays. LAB ON A CHIP 2021; 21:4249-4261. [PMID: 34608465 DOI: 10.1039/d1lc00542a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Microfluidic paper-based analytical devices (μPADs) are foundational devices for point-of-care testing, yet suffer from limitations in regards to their sensitivity and capability in handling complex assays. Here, we demonstrate an airflow-based, evaporative method that is capable of manipulating fluid flows within paper membranes to offer new functionalities for multistep delivery of reagents and improve the sensitivity of μPADs by 100-1000 times. This method applies an air-jet to a pre-wetted membrane, generating an evaporative gradient such that any solutes become enriched underneath the air-jet spot. By controlling the lateral position of this spot, the solutes in the paper strip are enriched and follow the air jet trajectory, driving the reactions and enhancing visualization for colorimetric readout in multistep assays. The technique has been successfully applied to drive the sequential delivery in multistep immunoassays as well as improve sensitivity for colorimetric detection assays for nucleic acids and proteins via loop-mediated isothermal amplification (LAMP) and ELISA. For colorimetric LAMP detection of the COVID-19 genome, enrichment of the solution on paper could enhance the contrast of the dye in order to more clearly distinguish between the positive and negative results to achieve a sensitivity of 3 copies of SARS-Cov-2 RNAs. For ELISA, enrichment of the oxidized TMB substrate yielded a sensitivity increase of two-to-three orders of magnitude when compared to non-enriched samples - having a limit of detection of around 200 fM for IgG. Therefore, this enrichment method represents a simple process that can be easily integrated into existing detection assays for controlling fluid flows and improving detection of biomarkers on paper.
Collapse
Affiliation(s)
- Edward Wang
- Department of Aerospace and Mechanical Engineering, Materials Science and Engineering Program, UC-San Diego, San Diego, USA.
| | - Zhilin Guo
- Department of Aerospace and Mechanical Engineering, Materials Science and Engineering Program, UC-San Diego, San Diego, USA.
| | - Rui Tang
- Department of Electrical and Computer Engineering, UC-San Diego, San Diego, USA
| | - Yu-Hwa Lo
- Department of Aerospace and Mechanical Engineering, Materials Science and Engineering Program, UC-San Diego, San Diego, USA.
- Department of Electrical and Computer Engineering, UC-San Diego, San Diego, USA
| |
Collapse
|
49
|
Eco-friendly pH detecting paper-based analytical device: Towards process intensification. Anal Chim Acta 2021; 1182:338953. [PMID: 34602199 DOI: 10.1016/j.aca.2021.338953] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 07/24/2021] [Accepted: 08/05/2021] [Indexed: 11/21/2022]
Abstract
This work describes the development of a miniaturized paper-based pH detection platform using natural dye extracted from red cabbage (Brassica oleracea). The easily available paper was used as a substrate and the requisite patterned zone was created with the aid of a punching machine. Experimental parameters were optimized to obtain the best signal readout. The performance of the device at different pH values was quantitatively assessed using digital image analysis with various color space models. Regression analysis suggested that a∗ parameter in CIEL∗a∗b∗ color space model, which captures the variations on the red-green scale, exhibited the best fit with experimental data (R2 = 0.9754). This parameter was used for the quantitative estimation of pH variations in a wide range of pH (1-12). A series of real test samples were examined using the paper-based device and results validated with a standard pH meter. The use of paper and natural dye makes the device eco-friendly. The simplicity of fabrication, ease of usage and low reagent and sample volume requirements render the methodology suitable for in situ measurements of pH. The approach demonstrated here would pave the way for the development of clean, sustainable and intensified chemical sensor technologies.
Collapse
|
50
|
|