1
|
Zhang Y, Hu X, Wang Q. Review of microchip analytical methods for the determination of pathogenic Escherichia coli. Talanta 2021; 232:122410. [PMID: 34074400 DOI: 10.1016/j.talanta.2021.122410] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 03/28/2021] [Accepted: 04/07/2021] [Indexed: 12/13/2022]
Abstract
Bacterial infections remain the principal cause of mortality worldwide, making the detection of pathogenic bacteria highly important, especially Escherichia coli (E. coli). Current E. coli detection methods are labour-intensive, time-consuming, or require expensive instrumentation, making it critical to develop new strategies that are sensitive and specific. Microchips are an automated analytical technique used to analyse food based on their separation efficiency and low analyte consumption, which make them the preferred method to detect pathogenic bacteria. This review presents an overview of microchip-based analytical methods for analysing E. coli, which were published in recent years. Specifically, this review focuses on current research based on microchips for the detection of E. coli and reviews the limitations of microchip-based methods and future perspectives for the analysis of pathogenic bacteria.
Collapse
Affiliation(s)
- Yan Zhang
- Faculty of Science, Kunming University of Science and Technology, Kunming, 650500, China; School of Chemistry and Molecular Engineering, East China Normal University, 500 Dongchuan Road, Shanghai, 200241, PR China
| | - Xianzhi Hu
- Faculty of Science, Kunming University of Science and Technology, Kunming, 650500, China.
| | - Qingjiang Wang
- School of Chemistry and Molecular Engineering, East China Normal University, 500 Dongchuan Road, Shanghai, 200241, PR China.
| |
Collapse
|
2
|
Biocomputing label-free security system based on homogenous ligation chain reaction-induced dramatic change in melting temperature for screening single nucleotide polymorphisms. Talanta 2020; 218:121141. [PMID: 32797898 DOI: 10.1016/j.talanta.2020.121141] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Revised: 05/03/2020] [Accepted: 05/07/2020] [Indexed: 12/17/2022]
Abstract
The development of smart platform with accurate, inexpensive and reliable detection of single-nucleotide polymorphisms (SNPs) has long been concerned in the fields of medical diagnosis and basic research. Here, we present a ligation chain reaction (LCR)-based sensing system for the cost-effective screening of SNPs by simply conducting DNA melting analysis. No chemical modification is required and the signaling operation is accomplished in homogeneous solution, circumventing the complex modification process and possibly compromised enzymatic activity associated with heterogeneous materials, such as quantum dot (QD) and gold nanoparticle (GNP). Due to the enzymatic catalysis and high fidelity of ligase, the system is capable of executing signal amplification, providing a high sensitivity and selectivity. KRAS gene is easily recognized and the site-specific mutation of guanine (G) to adenine (A), thymine (T) or cytosine (C) is accurately screened. Moreover, the excellent reliability was demonstrated by blind test and recovery test. LCR-based signaling mechanism was further used to develop the biocomputing security system, and two logic gates consisting of four single-stranded DNAs (ssDNAs) offer a double insurance to protect the information against illegal invasion, guaranteeing the reliability of output information. Once in the absence of one essential factor, the security system was always locked regardless of target key, serving as a novel strategy to ensure the safety of output information at molecular level. As a proof-of-concept scheme, this contribution introduces new insight into the development of DNA security systems and the exploitation of powerful signal transduction strategy suitable for rapid and convenient disease diagnosis.
Collapse
|
3
|
Zhu H, Zhang H, Ni S, Korabečná M, Yobas L, Neuzil P. The vision of point-of-care PCR tests for the COVID-19 pandemic and beyond. Trends Analyt Chem 2020; 130:115984. [PMID: 32834243 PMCID: PMC7369599 DOI: 10.1016/j.trac.2020.115984] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Infectious diseases, such as the most recent case of coronavirus disease 2019, have brought the prospect of point-of-care (POC) diagnostic tests into the spotlight. A rapid, accurate, low-cost, and easy-to-use test in the field could stop epidemics before they develop into full-blown pandemics. Unfortunately, despite all the advances, it still does not exist. Here, we critically review the limited number of prototypes demonstrated to date that is based on a polymerase chain reaction (PCR) and has come close to fulfill this vision. We summarize the requirements for the POC-PCR tests and then go on to discuss the PCR product-detection methods, the integration of their functional components, the potential applications, and other practical issues related to the implementation of lab-on-a-chip technologies. We conclude our review with a discussion of the latest findings on nucleic acid-based diagnosis.
Collapse
Affiliation(s)
- Hanliang Zhu
- Department of Microsystem Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an, 710072 Shaanxi, PR China
| | - Haoqing Zhang
- Department of Microsystem Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an, 710072 Shaanxi, PR China
| | - Sheng Ni
- Department of Electronic and Computer Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, S.A.R., PR China
| | - Marie Korabečná
- Institute of Biology and Medical Genetics, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Albertov 4, Prague 2, Czech Republic
| | - Levent Yobas
- Department of Electronic and Computer Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, S.A.R., PR China,Corresponding author
| | - Pavel Neuzil
- Department of Microsystem Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an, 710072 Shaanxi, PR China,CEITEC Brno University of Technology, Purkyňova 123, 612 00 Brno, Czech Republic,Faculty of Electrical Engineering and Communications, Brno University of Technology, Technická 3058/10, 616 00 Brno, Czech Republic,Corresponding author. Department of Microsystem Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an, 710072 Shaanxi, PR China
| |
Collapse
|
4
|
Microfluidics-Based Organism Isolation from Whole Blood: An Emerging Tool for Bloodstream Infection Diagnosis. Ann Biomed Eng 2019; 47:1657-1674. [PMID: 30980291 DOI: 10.1007/s10439-019-02256-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 03/27/2019] [Indexed: 12/11/2022]
Abstract
The diagnosis of bloodstream infections presents numerous challenges, in part, due to the low concentration of pathogens present in the peripheral bloodstream. As an alternative to existing time-consuming, culture-based diagnostic methods for organism identification, microfluidic devices have emerged as rapid, high-throughput and integrated platforms for bacterial and fungal enrichment, detection, and characterization. This focused review serves to highlight and compare the emerging microfluidic platforms designed for the isolation of sepsis-causing pathogens from blood and suggest important areas for future research.
Collapse
|
5
|
Chylewska A, Ogryzek M, Makowski M. Modern Approach to Medical Diagnostics - the Use of Separation Techniques in Microorganisms Detection. Curr Med Chem 2019; 26:121-165. [DOI: 10.2174/0929867324666171023164813] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2016] [Revised: 04/20/2017] [Accepted: 05/20/2016] [Indexed: 11/22/2022]
Abstract
Background:Analytical chemistry and biotechnology as an interdisciplinary fields of science have been developed during many years and are experiencing significant growth, to cover a wide range of microorganisms separation techniques and methods, utilized for medical therapeutic and diagnostic purposes. Currently scientific reports contribute by introducing electrophoretical and immunological methods and formation of devices applied in food protection (avoiding epidemiological diseases) and healthcare (safety ensuring in hospitals).Methods:Electrophoretic as well as nucleic-acid-based or specific immunological methods have contributed tremendously to the advance of analyses in recent three decades, particularly in relation to bacteria, viruses and fungi identifications, especially in medical in vitro diagnostics, as well as in environmental or food protection.Results:The paper presents the pathogen detection competitiveness of these methods against conventional ones, which are still too time consuming and also labor intensive. The review is presented in several parts following the current trends in improved pathogens separation and detection methods and their subsequent use in medical diagnosis.Discussion:Part one, consists of elemental knowledge about microorganisms as an introduction to their characterization: descriptions of divisions, sizes, membranes (cells) components. Second section includes the development, new technological and practical solution descriptions used in electrophoretical procedures during microbes analyses, with special attention paid to bio-samples analyses like blood, urine, lymph or wastewater. Third part covers biomolecular areas that have created a basis needed to identify the progress, limitations and challenges of nucleic-acid-based and immunological techniques discussed to emphasize the advantages of new separative techniques in selective fractionating of microorganisms.
Collapse
Affiliation(s)
- Agnieszka Chylewska
- Laboratory of Intermolecular Interactions, Faculty of Chemistry, University of Gdansk, Wita Stwosza 63, 80- 308 Gdansk, Poland
| | - Małgorzata Ogryzek
- Laboratory of Intermolecular Interactions, Faculty of Chemistry, University of Gdansk, Wita Stwosza 63, 80- 308 Gdansk, Poland
| | - Mariusz Makowski
- Laboratory of Intermolecular Interactions, Faculty of Chemistry, University of Gdansk, Wita Stwosza 63, 80- 308 Gdansk, Poland
| |
Collapse
|
6
|
Lee J, Mena SE, Burns MA. Micro-Particle Operations Using Asymmetric Traps. Sci Rep 2019; 9:1278. [PMID: 30718531 PMCID: PMC6362267 DOI: 10.1038/s41598-018-37454-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Accepted: 11/28/2018] [Indexed: 12/19/2022] Open
Abstract
Micro-particle operations in many lab-on-a-chip devices require active-type techniques that are accompanied by complex fabrication and operation. The present study describes an alternative method using a passive microfluidic scheme that allows for simpler operation and, therefore, potentially less expensive devices. We present three practical micro-particle operations using our previously developed passive mechanical trap, the asymmetric trap, in a non-acoustic oscillatory flow field. First, we demonstrate size-based segregation of both binary and ternary micro-particle mixtures using size-dependent trap-particle interactions to induce different transport speeds for each particle type. The degree of segregation, yield, and purity of the binary segregations are 0.97 ± 0.02, 0.96 ± 0.06, and 0.95 ± 0.05, respectively. Next, we perform a solution exchange by displacing particles from one solution into another in a trap array. Lastly, we focus and split groups of micro-particles by exploiting the transport polarity of asymmetric traps. These operations can be implemented in any closed fluidic circuit containing asymmetric traps using non-acoustic oscillatory flow, and they open new opportunities to flexibly control micro-particles in integrated lab-on-a-chip platforms with minimal external equipment.
Collapse
Affiliation(s)
- Jaesung Lee
- Department of Chemical Engineering, University of Michigan, Ann Arbor, 48109, USA
| | - Sarah E Mena
- Department of Chemical Engineering, University of Michigan, Ann Arbor, 48109, USA
| | - Mark A Burns
- Department of Chemical Engineering, University of Michigan, Ann Arbor, 48109, USA. .,Department of Biomedical Engineering, University of Michigan, Ann Arbor, 48109, USA.
| |
Collapse
|
7
|
Hao X, Yeh P, Qin Y, Jiang Y, Qiu Z, Li S, Le T, Cao X. Aptamer surface functionalization of microfluidic devices using dendrimers as multi-handled templates and its application in sensitive detections of foodborne pathogenic bacteria. Anal Chim Acta 2019; 1056:96-107. [PMID: 30797466 DOI: 10.1016/j.aca.2019.01.035] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2019] [Accepted: 01/23/2019] [Indexed: 12/20/2022]
Abstract
A microfluidic system that incorporates both dendrimers and aptamers to detect E. coli O157:H7 is developed. To achieve this, generation 7-polyamidoamine dendrimers were immobilized onto the detection surfaces of PDMS microfluidic channels; subsequently aptamers against E. coli O157:H7 were conjugated onto the microchannel surfaces via the immobilized dendrimers as templates. Surface modifications were characterized by FTIR, XPS, water contact angles, fluorescence microscopy and AFM to confirm the success of each surface modification steps. The efficacy of this simple microchannel in detection was investigated using E. coli O157:H7 spiked samples. Our results showed that this interesting approach significantly increased the amount of aptamers available on the microfluidic channel surfaces to capture E. coli O157:H7 cells to allow sensitive detection, which in turn resulted in detections of E. coli O157:H7 cells at a low limit of detection of 102 cells mL-1. The results also demonstrated that in comparison with the generation 4-polyamidoamine dendrimers (G4) modified microchannels, those modified with G7 showed enhanced detection signals, improved target capturing efficiencies, and at higher throughput. This simple whole cell detection design has not been reported in the literature and it is an interesting and effective approach to developing a sensitive and rapid detection platform for foodborne pathogenic bacteria.
Collapse
Affiliation(s)
- Xingkai Hao
- Department of Chemical and Biological Engineering, University of Ottawa, Ottawa, Ontario, K1N 6N5, Canada
| | - Poying Yeh
- Department of Chemical and Biological Engineering, University of Ottawa, Ottawa, Ontario, K1N 6N5, Canada
| | - Yubo Qin
- Department of Chemical and Biological Engineering, University of Ottawa, Ottawa, Ontario, K1N 6N5, Canada
| | - Yuqian Jiang
- Department of Chemical and Biological Engineering, University of Ottawa, Ottawa, Ontario, K1N 6N5, Canada
| | - Zhenyu Qiu
- Nanchang Institute of Technology, 901 Yingxiong Road, Nanchang, Jiangxi, 330044, China
| | - Shuying Li
- Department of Chemical and Biological Engineering, University of Ottawa, Ottawa, Ontario, K1N 6N5, Canada
| | - Tao Le
- College of Life Science, Chongqing Normal University, Shapingba, Chongqing, 400047, China
| | - Xudong Cao
- Department of Chemical and Biological Engineering, University of Ottawa, Ottawa, Ontario, K1N 6N5, Canada; Ottawa-Carlton Institute of Biomedical Engineering, Ottawa, Ontario, K1N 6N5, Canada.
| |
Collapse
|
8
|
Kalsi S, Valiadi M, Turner C, Sutton M, Morgan H. Sample pre-concentration on a digital microfluidic platform for rapid AMR detection in urine. LAB ON A CHIP 2018; 19:168-177. [PMID: 30516215 DOI: 10.1039/c8lc01249k] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
There is a growing need for rapid diagnostic methods to support stewardship of antibiotics.
Collapse
Affiliation(s)
- Sumit Kalsi
- Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK.
| | | | | | | | | |
Collapse
|
9
|
|
10
|
Tentori AM, Nagarajan MB, Kim JJ, Zhang WC, Slack FJ, Doyle PS. Quantitative and multiplex microRNA assays from unprocessed cells in isolated nanoliter well arrays. LAB ON A CHIP 2018; 18:2410-2424. [PMID: 29998262 PMCID: PMC6081239 DOI: 10.1039/c8lc00498f] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
MicroRNAs (miRNAs) have recently emerged as promising biomarkers for the profiling of diseases. Translation of miRNA biomarkers to clinical practice, however, remains a challenge due to the lack of analysis platforms for sensitive, quantitative, and multiplex miRNA assays that have simple and robust workflows suitable for translation. The platform we present here utilizes functionalized hydrogel posts contained within isolated nanoliter well reactors for quantitative and multiplex assays directly from unprocessed cell samples without the need of prior nucleic acid extraction. Simultaneous reactor isolation and delivery of miRNA extraction reagents is achieved by sealing an array of wells containing the functionalized hydrogel posts and cells against another array of wells containing lysis and extraction reagents. The nanoliter well array platform features >100× better sensitivity compared to previous technology utilizing hydrogel particles without relying on signal amplification and enables >100 parallel assays in a single device. These advances provided by this platform lay the groundwork for translatable and robust analysis technologies for miRNA expression profiling in samples with small populations of cells and in precious, material-limited samples.
Collapse
Affiliation(s)
- Augusto M. Tentori
- Department of Chemical Engineering
, Massachusetts Institute of Technology
,
Cambridge
, USA
.
; Tel: +1 617 253 4534
| | - Maxwell B. Nagarajan
- Department of Chemical Engineering
, Massachusetts Institute of Technology
,
Cambridge
, USA
.
; Tel: +1 617 253 4534
| | - Jae Jung Kim
- Department of Chemical Engineering
, Massachusetts Institute of Technology
,
Cambridge
, USA
.
; Tel: +1 617 253 4534
| | - Wen Cai Zhang
- Department of Pathology
, Beth Israel Deaconess Medical Center/Harvard Medical School
,
Boston
, USA
| | - Frank J. Slack
- Department of Pathology
, Beth Israel Deaconess Medical Center/Harvard Medical School
,
Boston
, USA
| | - Patrick S. Doyle
- Department of Chemical Engineering
, Massachusetts Institute of Technology
,
Cambridge
, USA
.
; Tel: +1 617 253 4534
| |
Collapse
|
11
|
Negou JT, Hu J, Li X, Easley CJ. Advancement of analytical modes in a multichannel, microfluidic droplet-based sample chopper employing phase-locked detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2018; 10:3436-3443. [PMID: 30505354 PMCID: PMC6258173 DOI: 10.1039/c8ay00947c] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
In this work, we expand upon our recently developed droplet-based sample chopping concepts by introducing a multiplexed fluidic micro-chopper device (μChopper). Six aqueous input channels were integrated with a single oil input, and each of these seven channels was controlled by a pneumatic valve for automated sampling through software control. This improved design, while maintaining high precision in valve-based droplet generation at bandwidths of 0.03 to 0.05 Hz, enabled a variety of analytical modes to be employed on-chip compared to previous devices limited to sample/reference alternations. The device was analytically validated for real-time, continuous calibration with a single sample and five standards; multiplexed analysis during calibration using a mixed mode; and standard addition through spiking of six sample droplets with varying amounts of standard. Finally, the standard addition mode was applied to protein quantification in human serum samples using on-chip, homogeneous fluorescence immunoassays. Ultimately, with only ~1.2 μL of total analyzed solution volume- representing 100-fold and 75-fold reductions in reagent and serum volumes, respectively-we were able to generate full, six-point standard addition curves in only 1.5 min, and results correlated well with those from standard plate-reader equipment. This work thus exploited microfluidic valves for both their automation and droplet phase-locking capabilities, resulting in a micro-analytical tool capable of complex analytical interrogation modes on sub-microliter sample volumes while also leveraging drastic noise rejection via lock-in detection. The multichannel μChopper device should prove particularly useful in analyzing precious biological samples or for dynamic analyses at small volume scales.
Collapse
Affiliation(s)
- Jean T. Negou
- Department of Chemistry and Biochemistry, Auburn University, Auburn, AL 36849, USA
| | - Juan Hu
- Department of Chemistry and Biochemistry, Auburn University, Auburn, AL 36849, USA
| | - Xiangpeng Li
- Department of Chemistry and Biochemistry, Auburn University, Auburn, AL 36849, USA
| | | |
Collapse
|
12
|
High-Speed Lateral Flow Strategy for a Fast Biosensing with an Improved Selectivity and Binding Affinity. SENSORS 2018; 18:s18051507. [PMID: 29748509 PMCID: PMC5982462 DOI: 10.3390/s18051507] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/10/2018] [Revised: 05/03/2018] [Accepted: 05/08/2018] [Indexed: 11/16/2022]
Abstract
We report a high-speed lateral flow strategy for a fast biosensing with an improved selectivity and binding affinity even under harsh conditions. In this strategy, biosensors were fixed at a location away from the center of a round shape disk, and the disk was rotated to create the lateral flow of a target solution on the biosensors during the sensing measurements. Experimental results using the strategy showed high reaction speeds, high binding affinity, and low nonspecific adsorptions of target molecules to biosensors. Furthermore, binding affinity between target molecules and sensing molecules was enhanced even in harsh conditions such as low pH and low ionic strength conditions. These results show that the strategy can improve the performance of conventional biosensors by generating high-speed lateral flows on a biosensor surface. Therefore, our strategy can be utilized as a simple but powerful tool for versatile bio and medical applications.
Collapse
|
13
|
Lee J, Burns MA. One-Way Particle Transport Using Oscillatory Flow in Asymmetric Traps. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2018; 14:10.1002/smll.201702724. [PMID: 29377529 PMCID: PMC6324199 DOI: 10.1002/smll.201702724] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2017] [Revised: 12/03/2017] [Indexed: 06/07/2023]
Abstract
One challenge of integrating of passive, microparticles manipulation techniques into multifunctional microfluidic devices is coupling the continuous-flow format of most systems with the often batch-type operation of particle separation systems. Here, a passive fluidic technique-one-way particle transport-that can conduct microparticle operations in a closed fluidic circuit is presented. Exploiting pass/capture interactions between microparticles and asymmetric traps, this technique accomplishes a net displacement of particles in an oscillatory flow field. One-way particle transport is achieved through four kinds of trap-particle interactions: mechanical capture of the particle, asymmetric interactions between the trap and the particle, physical collision of the particle with an obstacle, and lateral shift of the particle into a particle-trapping stream. The critical dimensions for those four conditions are found by numerically solving analytical mass balance equations formulated using the characteristics of the flow field in periodic obstacle arrays. Visual observation of experimental trap-particle dynamics in low Reynolds number flow (<0.01) confirms the validity of the theoretical predictions. This technique can transport hundreds of microparticles across trap rows in only a few fluid oscillations (<500 ms per oscillation) and separate particles by their size differences.
Collapse
Affiliation(s)
- Jaesung Lee
- Department of Chemical Engineering, University of Michigan at Ann Arbor, 3074 H. H. Dow, 2300 Hayward St, Ann Arbor, MI, 48109, USA
| | - Mark A Burns
- Department of Chemical Engineering, University of Michigan at Ann Arbor, 3074 H. H. Dow, 2300 Hayward St, Ann Arbor, MI, 48109, USA
- Department of Biomedical Engineering, University of Michigan, 1107 Carl A. Gerstacker, 2200 Bonisteel Blvd, Ann Arbor, MI, 48109, USA
| |
Collapse
|
14
|
Zhuang B. Introduction. DEVELOPMENT OF A FULLY INTEGRATED “SAMPLE-IN-ANSWER-OUT” SYSTEM FOR AUTOMATIC GENETIC ANALYSIS 2018:1-30. [DOI: 10.1007/978-981-10-4753-4_1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
15
|
Zhuang B. Integrated Module for Automated DNA Extraction and Amplification. DEVELOPMENT OF A FULLY INTEGRATED “SAMPLE-IN-ANSWER-OUT” SYSTEM FOR AUTOMATIC GENETIC ANALYSIS 2018:63-87. [DOI: 10.1007/978-981-10-4753-4_3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
16
|
Fu Y, Zhou X, Xing D. Lab-on-capillary: a rapid, simple and quantitative genetic analysis platform integrating nucleic acid extraction, amplification and detection. LAB ON A CHIP 2017; 17:4334-4341. [PMID: 29139529 DOI: 10.1039/c7lc01107e] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In this work, we describe for the first time a genetic diagnosis platform employing a polydiallyldimethylammonium chloride (PDDA)-modified capillary and a liquid-based thermalization system for rapid, simple and quantitative DNA analysis with minimal user interaction. Positively charged PDDA is modified on the inner surface of the silicon dioxide capillary by using an electrostatic self-assembly approach that allows the negatively charged DNA to be separated from the lysate in less than 20 seconds. The capillary loaded with the PCR mix is incorporated in the thermalization system, which can achieve on-site real-time PCR. This system is based on the circulation of pre-heated liquids in the chamber, allowing for high-speed thermalization of the capillary and fast amplification. Multiple targets can be simultaneously analysed with multiplex spatial melting. Starting with live Escherichia coli (E. coli) cells in milk, as a realistic sample, the current method can achieve DNA extraction, amplification, and detection within 40 min.
Collapse
Affiliation(s)
- Yu Fu
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
| | | | | |
Collapse
|
17
|
Priyanka B, Patil RK, Dwarakanath S. A review on detection methods used for foodborne pathogens. Indian J Med Res 2017; 144:327-338. [PMID: 28139531 PMCID: PMC5320838 DOI: 10.4103/0971-5916.198677] [Citation(s) in RCA: 96] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
Foodborne pathogens have been a cause of a large number of diseases worldwide and more so in developing countries. This has a major economic impact. It is important to contain them, and to do so, early detection is very crucial. Detection and diagnostics relied on culture-based methods to begin with and have developed in the recent past parallel to the developments towards immunological methods such as enzyme-linked immunosorbent assays (ELISA) and molecular biology-based methods such as polymerase chain reaction (PCR). The aim has always been to find a rapid, sensitive, specific and cost-effective method. Ranging from culturing of microbes to the futuristic biosensor technology, the methods have had this common goal. This review summarizes the recent trends and brings together methods that have been developed over the years.
Collapse
Affiliation(s)
- B Priyanka
- Department of Applied Zoology, Mangalore University, Mangaluru, India
| | | | | |
Collapse
|
18
|
Krivitsky V, Zverzhinetsky M, Patolsky F. Antigen-Dissociation from Antibody-Modified Nanotransistor Sensor Arrays as a Direct Biomarker Detection Method in Unprocessed Biosamples. NANO LETTERS 2016; 16:6272-6281. [PMID: 27579528 DOI: 10.1021/acs.nanolett.6b02584] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
The detection of biomolecules is critical for a wide spectrum of applications in life sciences and medical diagnosis. Nonetheless, biosamples are highly complex solutions, which contain an enormous variety of biomolecules, cells, and chemical species. Consequently, the intrinsic chemical complexity of biosamples results in a significant analytical background noise and poses an immense challenge to any analytical measurement, especially when applied without prior efficient separation and purification steps. Here, we demonstrate the application of antigen-dissociation regime, from antibody-modified Si-nanowire sensors, as a simple and effective direct sensing mechanism of biomarkers of interest in complex biosamples, such as serum and untreated blood, which does not require ex situ time-consuming biosample manipulation steps, such as centrifugation, filtering, preconcentration, and desalting, thus overcoming the detrimental Debye screening limitation of nanowire-based biosensors. We found that two key parameters control the capability to perform quantitative biomarkers analysis in biosamples: (i) the affinity strength (koff rate) of the antibody-antigen recognition pair, which dictates the time length of the high-affinity slow dissociation subregime, and (ii) the "flow rate" applied during the solution exchange dissociation step, which controls the time width of the low-affinity fast-dissociation subregime. Undoubtedly, this is the simplest and most convenient approach for the SiNW FET-based detection of antigens in complex untreated biosamples. The lack of ex situ biosample manipulation time-consuming processes enhances the portability of the sensing platform and reduces to minimum the required volume of tested sample, as it allows the direct detection of untreated biosamples (5-10 μL blood or serum), while readily reducing the detection cycle duration to less than 5 min, factors of great importance in near-future point-of-care medical applications. We believe this is the first ever reported demonstration on the real-time, direct label-free sensing of biomarkers from untreated blood samples, using SiNW-based FET devices, while not compromising the ultrasensitive sensing capabilities inherent to these devices.
Collapse
Affiliation(s)
- Vadim Krivitsky
- School of Chemistry, The Raymond and Beverly Sackler Faculty of Exact Sciences, Tel-Aviv University , Tel Aviv 69978, Israel
| | - Marina Zverzhinetsky
- School of Chemistry, The Raymond and Beverly Sackler Faculty of Exact Sciences, Tel-Aviv University , Tel Aviv 69978, Israel
| | - Fernando Patolsky
- School of Chemistry, The Raymond and Beverly Sackler Faculty of Exact Sciences, Tel-Aviv University , Tel Aviv 69978, Israel
- Department of Materials Science and Engineering, The Iby and Aladar Fleischman Faculty of Engineering, Tel-Aviv University , Tel Aviv 69978, Israel
| |
Collapse
|
19
|
HE QD, HUANG DP, HUANG G, CHEN ZG. Advance in Research of Microfluidic Polymerase Chain Reaction Chip. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2016. [DOI: 10.1016/s1872-2040(16)60921-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
20
|
Valiadi M, Kalsi S, Jones IGF, Turner C, Sutton JM, Morgan H. Simple and rapid sample preparation system for the molecular detection of antibiotic resistant pathogens in human urine. Biomed Microdevices 2016; 18:18. [PMID: 26846875 PMCID: PMC4742488 DOI: 10.1007/s10544-016-0031-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Antibiotic resistance in urinary tract infections (UTIs) can cause significant complications without quick detection and appropriate treatment. We describe a new approach to capture, concentrate and prepare amplification-ready DNA from antibiotic resistant bacteria in human urine samples. Klebsiella pneumoniae NCTC13443 (bla CTX-M-15 positive) spiked into filtered human urine was used as a model system. Bacteria were captured using anion exchange diaethylaminoethyl (DEAE) magnetic microparticles and concentrated 200-fold within ~3.5 min using a custom, valve-less microfluidic chip. Eight samples were processed in parallel, and DNA was released using heat lysis from an integrated resistive heater. The crude cell lysate was used for real time Recombinase Polymerase Amplification (RPA) of the bla CTX-M-15 gene. The end to end processing time was approximately 15 min with a limit of detection of 1000 bacteria in 1 mL urine.
Collapse
Affiliation(s)
- Martha Valiadi
- Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ, UK
- Institute for Life Sciences, University of Southampton, Southampton, SO17 1BJ, UK
| | - Sumit Kalsi
- Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ, UK
- Institute for Life Sciences, University of Southampton, Southampton, SO17 1BJ, UK
| | - Isaac G F Jones
- Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ, UK
- Institute for Life Sciences, University of Southampton, Southampton, SO17 1BJ, UK
| | - Carrie Turner
- National Infections Service, Public Health England, Porton Down, Salisbury, SP4 0JG, UK
| | - J Mark Sutton
- National Infections Service, Public Health England, Porton Down, Salisbury, SP4 0JG, UK
| | - Hywel Morgan
- Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ, UK.
- Institute for Life Sciences, University of Southampton, Southampton, SO17 1BJ, UK.
| |
Collapse
|
21
|
Ali I, Alharbi OML, Marsin Sanagi M. Nano-capillary electrophoresis for environmental analysis. ENVIRONMENTAL CHEMISTRY LETTERS 2015; 14:79-98. [PMID: 32214934 PMCID: PMC7087629 DOI: 10.1007/s10311-015-0547-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2015] [Accepted: 12/11/2015] [Indexed: 06/10/2023]
Abstract
Many analytical techniques have been used to monitor environmental pollutants. But most techniques are not capable to detect pollutants at nanogram levels. Hence, under such conditions, absence of pollutants is often assumed, whereas pollutants are in fact present at low but undetectable concentrations. Detection at low levels may be done by nano-capillary electrophoresis, also named microchip electrophoresis. Here, we review the analysis of pollutants by nano-capillary electrophoresis. We present instrumentations, applications, optimizations and separation mechanisms. We discuss the analysis of metal ions, pesticides, polycyclic aromatic hydrocarbons, explosives, viruses, bacteria and other contaminants. Detectors include ultraviolet-visible, fluorescent, conductivity, atomic absorption spectroscopy, refractive index, atomic fluorescence spectrometry, atomic emission spectroscopy, inductively coupled plasma, inductively coupled plasma-mass spectrometry, mass spectrometry, time-of-flight mass spectrometry and nuclear magnetic resonance. Detection limits ranged from nanogram to picogram levels.
Collapse
Affiliation(s)
- Imran Ali
- Department of Chemistry, Jamia Millia Islamia (Central University), New Delhi, 110025 India
| | - Omar M. L. Alharbi
- Biology Department, Faculty of Sciences, Taibah University, P.O. Box 30002, Madinah Al-Munawarah, 41477 Saudi Arabia
| | - Mohd. Marsin Sanagi
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia (UTM), 81310 Johor Bahru, Johor Malaysia
- Ibnu Sina Institute for Fundamental Science Studies, Nanotechnology Research Alliance, Universiti Teknologi Malaysia (UTM), 81310 Johor Bahru, Johor Malaysia
| |
Collapse
|
22
|
Kim YT, Lee D, Heo HY, Kim DH, Seo TS. An integrated slidable and valveless microdevice with solid phase extraction, polymerase chain reaction, and immunochromatographic strip parts for multiplex colorimetric pathogen detection. LAB ON A CHIP 2015; 15:4148-4155. [PMID: 26394907 DOI: 10.1039/c5lc00801h] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
A total integrated genetic analysis microsystem was developed, which consisted of solid phase extraction (SPE), polymerase chain reaction (PCR), and immunochromatographic strip (ICS) parts for multiplex colorimetric detection of pathogenic Staphylococcus aureus (S. aureus) and Escherichia coli O157:H7 (E. coli O157:H7) on a portable genetic analyzer. Utilizing a slidable chamber, which is a movable glass wafer, complex microvalves could be eliminated for fluidic control in the microchannel, which could simplify the chip design and chip operation. The integrated slidable microdevice was composed of 4 layers: a 4-point Pt/Ti resistance temperature detector (RTD) wafer, a micro-patterned channel wafer, a 2 μL volume slidable chamber, and an ICS. The entire process from the DNA extraction in the SPE chamber to the detection of the target gene expression by the ICS was serially performed by simply sliding the slidable chamber from one part to another functional part. The total process for multiplex pathogenic S. aureus and E. coli O157:H7 detection on the integrated slidable microdevice was accomplished within 55 min with a detection limit of 5 cells. Furthermore, spiked bacteria samples in milk were also successfully analysed on the portable genetic analysis microsystem with sample-in-answer-out capability. The proposed total integrated microsystem is adequate for point-of-care DNA testing in that no microvalves and complex tubing systems are required due to the use of the slidable chamber and the bulky and expensive fluorescence or electrochemical detectors are not necessary due to the ICS based colorimetric detection.
Collapse
Affiliation(s)
- Yong Tae Kim
- Department of Chemical and Biomolecular Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 305-701, Korea.
| | | | | | | | | |
Collapse
|
23
|
Willis PA, Creamer JS, Mora MF. Implementation of microchip electrophoresis instrumentation for future spaceflight missions. Anal Bioanal Chem 2015; 407:6939-63. [PMID: 26253225 DOI: 10.1007/s00216-015-8903-z] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2015] [Revised: 06/30/2015] [Accepted: 07/03/2015] [Indexed: 11/27/2022]
Abstract
We present a comprehensive discussion of the role that microchip electrophoresis (ME) instrumentation could play in future NASA missions of exploration, as well as the current barriers that must be overcome to make this type of chemical investigation possible. We describe how ME would be able to fill fundamental gaps in our knowledge of the potential for past, present, or future life beyond Earth. Despite the great promise of ME for ultrasensitive portable chemical analysis, to date, it has never been used on a robotic mission of exploration to another world. We provide a current snapshot of the technology readiness level (TRL) of ME instrumentation, where the TRL is the NASA systems engineering metric used to evaluate the maturity of technology, and its fitness for implementation on missions. We explain how the NASA flight implementation process would apply specifically to ME instrumentation, and outline the scientific and technology development issues that must be addressed for ME analyses to be performed successfully on another world. We also outline research demonstrations that could be accomplished by independent researchers to help advance the TRL of ME instrumentation for future exploration missions. The overall approach described here for system development could be readily applied to a wide range of other instrumentation development efforts having broad societal and commercial impact.
Collapse
Affiliation(s)
- Peter A Willis
- Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Dr., Pasadena, CA, 91109, USA,
| | | | | |
Collapse
|
24
|
Durney BC, Crihfield CL, Holland LA. Capillary electrophoresis applied to DNA: determining and harnessing sequence and structure to advance bioanalyses (2009-2014). Anal Bioanal Chem 2015; 407:6923-38. [PMID: 25935677 PMCID: PMC4551542 DOI: 10.1007/s00216-015-8703-5] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2015] [Revised: 04/09/2015] [Accepted: 04/13/2015] [Indexed: 12/17/2022]
Abstract
This review of capillary electrophoresis methods for DNA analyses covers critical advances from 2009 to 2014, referencing 184 citations. Separation mechanisms based on free-zone capillary electrophoresis, Ogston sieving, and reptation are described. Two prevalent gel matrices for gel-facilitated sieving, which are linear polyacrylamide and polydimethylacrylamide, are compared in terms of performance, cost, viscosity, and passivation of electroosmotic flow. The role of capillary electrophoresis in the discovery, design, and characterization of DNA aptamers for molecular recognition is discussed. Expanding and emerging techniques in the field are also highlighted.
Collapse
Affiliation(s)
- Brandon C Durney
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, 26506, USA
| | | | | |
Collapse
|
25
|
A portable automatic endpoint detection system for amplicons of loop mediated isothermal amplification on microfluidic compact disk platform. SENSORS 2015; 15:5376-89. [PMID: 25751077 PMCID: PMC4435121 DOI: 10.3390/s150305376] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2014] [Revised: 01/19/2015] [Accepted: 01/28/2015] [Indexed: 11/17/2022]
Abstract
In recent years, many improvements have been made in foodborne pathogen detection methods to reduce the impact of food contamination. Several rapid methods have been developed with biosensor devices to improve the way of performing pathogen detection. This paper presents an automated endpoint detection system for amplicons generated by loop mediated isothermal amplification (LAMP) on a microfluidic compact disk platform. The developed detection system utilizes a monochromatic ultraviolet (UV) emitter for excitation of fluorescent labeled LAMP amplicons and a color sensor to detect the emitted florescence from target. Then it processes the sensor output and displays the detection results on liquid crystal display (LCD). The sensitivity test has been performed with detection limit up to 2.5 × 10−3 ng/µL with different DNA concentrations of Salmonella bacteria. This system allows a rapid and automatic endpoint detection which could lead to the development of a point-of-care diagnosis device for foodborne pathogens detection in a resource-limited environment.
Collapse
|
26
|
Tao W, Ai Y, Liu S, Lun CW, Yung PT. Determination of Alpha-Fetoprotein by a Microfluidic Miniature Quartz Crystal Microbalance. ANAL LETT 2015. [DOI: 10.1080/00032719.2014.968927] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
27
|
Cunha MV, Inácio J. Nucleic-acid testing, new platforms and nanotechnology for point-of-decision diagnosis of animal pathogens. Methods Mol Biol 2015; 1247:253-83. [PMID: 25399103 PMCID: PMC7122192 DOI: 10.1007/978-1-4939-2004-4_20] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Accurate disease diagnosis in animals is crucial for animal well-being but also for preventing zoonosis transmission to humans. In particular, livestock diseases may constitute severe threats to humans due to the particularly high physical contact and exposure and, also, be the cause of important economic losses, even in non-endemic countries, where they often arise in the form of rapid and devastating epidemics. Rapid diagnostic tests have been used for a long time in field situations, particularly during outbreaks. However, they mostly rely on serological approaches, which may confirm the exposure to a particular pathogen but may be inappropriate for point-of-decision (point-of-care) settings when emergency responses supported on early and accurate diagnosis are required. Moreover, they often exhibit modest sensitivity and hence significantly depend on later result confirmation in central or reference laboratories. The impressive advances observed in recent years in materials sciences and in nanotechnology, as well as in nucleic-acid synthesis and engineering, have led to an outburst of new in-the-bench and prototype tests for nucleic-acid testing towards point-of-care diagnosis of genetic and infectious diseases. Manufacturing, commercial, regulatory, and technical nature issues for field applicability more likely have hindered their wider entrance into veterinary medicine and practice than have fundamental science gaps. This chapter begins by outlining the current situation, requirements, difficulties, and perspectives of point-of-care tests for diagnosing diseases of veterinary interest. Nucleic-acid testing, particularly for the point of care, is addressed subsequently. A range of valuable signal transduction mechanisms commonly employed in proof-of-concept schemes and techniques born on the analytical chemistry laboratories are also described. As the essential core of this chapter, sections dedicated to the principles and applications of microfluidics, lab-on-a-chip, and nanotechnology for the development of point-of-care tests are presented. Microdevices already applied or under development for application in field diagnosis of animal diseases are reviewed.
Collapse
Affiliation(s)
- Mónica V. Cunha
- Instituto Nacional de Investigação Agrária e Veterinária, IP and Centro de Biologia Ambiental, Faculdade de Ciências, Universidade de Lisboa, Lisbon, Portugal
| | - João Inácio
- Instituto Nacional de Investigação Agrária e Veterinária, IP, Lisboa, Portugal and School of Pharmacy and Biomolecular Sciences, University of Brighton, Brighton, United Kingdom
| |
Collapse
|
28
|
fM to aM nucleic acid amplification for molecular diagnostics in a non-stick-coated metal microfluidic bioreactor. Sci Rep 2014; 4:7344. [PMID: 25475544 PMCID: PMC5384283 DOI: 10.1038/srep07344] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2014] [Accepted: 11/18/2014] [Indexed: 02/04/2023] Open
Abstract
A sensitive DNA isothermal amplification method for the detection of DNA at fM to aM concentrations for pathogen identification was developed using a non-stick-coated metal microfluidic bioreactor. A portable confocal optical detector was utilized to monitor the DNA amplification in micro- to nanoliter reaction assays in real-time, with fluorescence collection near the optical diffraction limit. The non-stick-coated metal microfluidic bioreactor, with a surface contact angle of 103°, was largely inert to bio-molecules, and DNA amplification could be performed in a minimum reaction volume of 40 nL. The isothermal nucleic acid amplification for Mycoplasma pneumoniae identification in the non-stick-coated microfluidic bioreactor could be performed at a minimum DNA template concentration of 1.3 aM, and a detection limit of three copies of genomic DNA was obtained. This microfluidic bioreactor offers a promising clinically relevant pathogen molecular diagnostic method via the amplification of targets from only a few copies of genomic DNA from a single bacterium.
Collapse
|
29
|
Hedman J, Knutsson R, Ansell R, Rådström P, Rasmusson B. Pre-PCR processing in bioterrorism preparedness: improved diagnostic capabilities for laboratory response networks. Biosecur Bioterror 2014; 11 Suppl 1:S87-101. [PMID: 23971826 DOI: 10.1089/bsp.2012.0090] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Diagnostic DNA analysis using polymerase chain reaction (PCR) has become a valuable tool for rapid detection of biothreat agents. However, analysis is often challenging because of the limited size, quality, and purity of the biological target. Pre-PCR processing is an integrated concept in which the issues of analytical limit of detection and simplicity for automation are addressed in all steps leading up to PCR amplification--that is, sampling, sample treatment, and the chemical composition of PCR. The sampling method should maximize target uptake and minimize uptake of extraneous substances that could impair the analysis--so-called PCR inhibitors. In sample treatment, there is a trade-off between yield and purity, as extensive purification leads to DNA loss. A cornerstone of pre-PCR processing is to apply DNA polymerase-buffer systems that are tolerant to specific sample impurities, thereby lowering the need for expensive purification steps and maximizing DNA recovery. Improved awareness among Laboratory Response Networks (LRNs) regarding pre-PCR processing is important, as ineffective sample processing leads to increased cost and possibly false-negative or ambiguous results, hindering the decision-making process in a bioterrorism crisis. This article covers the nature and mechanisms of PCR-inhibitory substances relevant for agroterrorism and bioterrorism preparedness, methods for quality control of PCR reactions, and applications of pre-PCR processing to optimize and simplify the analysis of various biothreat agents. Knowledge about pre-PCR processing will improve diagnostic capabilities of LRNs involved in the response to bioterrorism incidents.
Collapse
Affiliation(s)
- Johannes Hedman
- Johannes Hedman, PhD, is employed as a specialist at the Swedish National Laboratory of Forensic Science (SKL) and holds a research position at Applied Microbiology, Lund University. Rickard Knutsson, PhD, is Director of Security Department, National Veterinary Institute (SVA), Uppsala, Sweden . Ricky Ansell, PhD, is employed as forensic advisor and senior reporting officer at the Swedish National Laboratory of Forensic Science (SKL). Birgitta Rasmusson, PhD, is employed as research director at the Swedish National Laboratory of Forensic Science (SKL) and holds a position as adjunct professor at Applied Microbiology, Lund University. Peter Rådström, PhD, is employed as professor Applied Microbiology, Lund University
| | | | | | | | | |
Collapse
|
30
|
Kim TH, Park J, Kim CJ, Cho YK. Fully integrated lab-on-a-disc for nucleic acid analysis of food-borne pathogens. Anal Chem 2014; 86:3841-8. [PMID: 24635032 DOI: 10.1021/ac403971h] [Citation(s) in RCA: 160] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
This paper describes a micro total analysis system for molecular analysis of Salmonella, a major food-borne pathogen. We developed a centrifugal microfluidic device, which integrated the three main steps of pathogen detection, DNA extraction, isothermal recombinase polymerase amplification (RPA), and detection, onto a single disc. A single laser diode was utilized for wireless control of valve actuation, cell lysis, and noncontact heating in the isothermal amplification step, thereby yielding a compact and miniaturized system. To achieve high detection sensitivity, rare cells in large volumes of phosphate-buffered saline (PBS) and milk samples were enriched before loading onto the disc by using antibody-coated magnetic beads. The entire procedure, from DNA extraction through to detection, was completed within 30 min in a fully automated fashion. The final detection was carried out using lateral flow strips by direct visual observation; detection limit was 10 cfu/mL and 10(2) cfu/mL in PBS and milk, respectively. Our device allows rapid molecular diagnostic analysis and does not require specially trained personnel or expensive equipment. Thus, we expect that it would have an array of potential applications, including in the detection of food-borne pathogens, environmental monitoring, and molecular diagnostics in resource-limited settings.
Collapse
Affiliation(s)
- Tae-Hyeong Kim
- Department of Biomedical Engineering, School of Life Sciences, Ulsan National Institute of Science and Technology (UNIST) , UNIST-gil 50, Ulsan, 689-798, Republic of Korea
| | | | | | | |
Collapse
|
31
|
Gutiérrez-Capitán M, Ipatov A, Merlos Á, Jiménez-Jorquera C, Fernández-Sánchez C. Compact Electrochemical Flow System for the Analysis of Environmental Pollutants. ELECTROANAL 2014. [DOI: 10.1002/elan.201300473] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
32
|
Etayash H, Jiang K, Thundat T, Kaur K. Impedimetric detection of pathogenic Gram-positive bacteria using an antimicrobial peptide from class IIa bacteriocins. Anal Chem 2014; 86:1693-700. [PMID: 24400685 DOI: 10.1021/ac4034938] [Citation(s) in RCA: 63] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Real-time, label-free detection of Gram-positive bacteria with high selectivity and sensitivity is demonstrated using an interdigitated impedimetric array functionalized with naturally produced antimicrobial peptide from class IIa bacteriocins. The antimicrobial peptide, leucocin A, was chemically synthesized and covalently immobilized on interdigitated gold microelectrodes via the interaction between the C-terminal carboxylic acid of the peptide and free amines of a preattached thiolated linker. Exposing the peptide sensor to various concentrations of Gram-positive bacteria generated reproducible impedance spectra that detected peptide-bacteria interactions at a concentration of 1 cell/μL. The peptide sensor also selectively detected Listeria monocytogenes from other Gram-positive strains at a concentration of 10(3) cfu mL(-1). The study highlights that short peptide ligands from bacteriocin class offer high selectivity in bacterial detection and can be used in developing a robust, portable biosensor device to efficiently detect pathogenic Gram-positive bacteria in food samples.
Collapse
Affiliation(s)
- Hashem Etayash
- Faculty of Pharmacy and Pharmaceutical Sciences, University of Alberta , Edmonton, Alberta, T6G 2E1, Canada
| | | | | | | |
Collapse
|
33
|
Ritzi-Lehnert M. Development of chip-compatible sample preparation for diagnosis of infectious diseases. Expert Rev Mol Diagn 2014; 12:189-206. [DOI: 10.1586/erm.11.98] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
34
|
Han N, Shin JH, Han KH. An on-chip RT-PCR microfluidic device, that integrates mRNA extraction, cDNA synthesis, and gene amplification. RSC Adv 2014. [DOI: 10.1039/c3ra47980c] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
35
|
Zhu J, Qiu C, Palla M, Nguyen T, Russo JJ, Ju J, Lin Q. A Microfluidic Device for Multiplex Single-Nucleotide Polymorphism Genotyping. RSC Adv 2014; 4:4269-4277. [PMID: 26594354 PMCID: PMC4651459 DOI: 10.1039/c3ra44091e] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Single-nucleotide polymorphisms (SNPs) are the most abundant type of genetic variations; they provide the genetic fingerprint of individuals and are essential for genetic biomarker discoveries. Accurate detection of SNPs is of great significance for disease prevention, diagnosis and prognosis, and for prediction of drug response and clinical outcomes in patients. Nevertheless, conventional SNP genotyping methods are still limited by insufficient accuracy or labor-, time-, and resource-intensive procedures. Microfluidics has been increasingly utilized to improve efficiency; however, the currently available microfluidic genotyping systems still have shortcomings in accuracy, sensitivity, throughput and multiplexing capability. To address these challenges, we developed a multi-step SNP genotyping microfluidic device, which performs single-base extension of SNP specific primers and solid-phase purification of the extension products on a temperature-controlled chip. The products are ready for immediate detection by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), providing identification of the alleles at the target loci. The integrated device enables efficient and automated operation, while maintaining the high accuracy and sensitivity provided by MS. The multiplex genotyping capability was validated by performing rapid, accurate and simultaneous detection of 4 loci on a synthetic template. The microfluidic device has the potential to perform automatic, accurate, quantitative and high-throughput assays covering a broad spectrum of applications in biological and clinical research, drug development and forensics.
Collapse
Affiliation(s)
- Jing Zhu
- Department of Mechanical Engineering, Columbia University, New York, NY, 10027
| | - Chunmei Qiu
- Department of Chemical Engineering, Columbia University, New York, NY, 10027
| | - Mirkó Palla
- Department of Mechanical Engineering, Columbia University, New York, NY, 10027
- Department of Chemical Engineering, Columbia University, New York, NY, 10027
| | - ThaiHuu Nguyen
- Department of Mechanical Engineering, Columbia University, New York, NY, 10027
| | - James J. Russo
- Department of Chemical Engineering, Columbia University, New York, NY, 10027
| | - Jingyue Ju
- Department of Chemical Engineering, Columbia University, New York, NY, 10027
| | - Qiao Lin
- Department of Mechanical Engineering, Columbia University, New York, NY, 10027
| |
Collapse
|
36
|
Integration of sample pretreatment, μPCR, and detection for a total genetic analysis microsystem. Mikrochim Acta 2013. [DOI: 10.1007/s00604-013-1128-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
37
|
Gu P, Nishida T, Fan ZH. The use of polyurethane as an elastomer in thermoplastic microfluidic devices and the study of its creep properties. Electrophoresis 2013; 35:289-97. [PMID: 23868507 DOI: 10.1002/elps.201300160] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2013] [Revised: 06/04/2013] [Accepted: 06/05/2013] [Indexed: 01/04/2023]
Abstract
We report using polyurethane (PU) as an elastomer in microvalves integrated with thermoplastic microfluidic devices. Elastomer-based microvalves have been used in a number of applications and the elastomer often used is PDMS. Although it is a convenient material for prototyping, PDMS has been recognized to possess shortcomings such as solvent incompatibility and unfavorable manufacturability. We investigated the use of PU as an elastomer to address the challenges. A reliable method was developed to bond hybrid materials such as PU and cyclic olefin copolymer. The film thickness from 3.5 to 24.5 μm was studied to identify an appropriate thickness of PU films for desirable elasticity in microvalves. We integrated PU with thermally actuated, elastomer-based microvalves in thermoplastic devices. Valve actuations were demonstrated, and the relationship between the valve actuation time and heater power was studied. We compared PU with PDMS in terms of their microvalve performance. Valves with PDMS failed to function after two weeks since the thermal-sensitive solution evaporated through porous PDMS membrane, whereas the same valve with PU functioned properly after eight months. In addition, we evaluated the creep and creep recovery of PU, which is a common phenomenon of viscoelastic materials and is related to the long-term elastic property of PU after prolonged use.
Collapse
Affiliation(s)
- Pan Gu
- Interdisciplinary Microsystems Group, Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL, USA
| | | | | |
Collapse
|
38
|
Jung JH, Park BH, Choi YK, Seo TS. A microbead-incorporated centrifugal sample pretreatment microdevice. LAB ON A CHIP 2013; 13:3383-3388. [PMID: 23824467 DOI: 10.1039/c3lc50266j] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
In this study, we present a novel bead-incorporated centrifugal sample pretreatment microdevice to purify influenza A H3N2 viral RNA. Simple revolution per minute (RPM) control can lead to RNA capture on a bead-bed, and the sequential loading of a washing solution and an elution solution. Tetraethoxy orthosilicate (TEOS)-treated glass microbeads were utilized as a capture matrix. The sample pretreatment microdevice consists of four reservoirs for storing an RNA sample, a washing solution, an elution solution, and a collected sample, and they were merged at the microbead-bed microchannel. The washing solution reservoir and the elution solution reservoir were connected to the bead-bed microchannel through a capillary valve and a siphon channel, respectively. An RNA sample (a lysed influenza A H3N2 virus), a washing solution (70% ethanol) and an elution solution (water or a reverse transcription-polymerase chain reaction (RT-PCR) cocktail) were loaded into the designated reservoirs, and they were successively transported to the bead-bed by RPM control owing to the optimized channel design. Purified RNAs could be obtained in 440 s. Then, a target H3 gene was amplified by an off-chip based real-time RT-PCR to evaluate the capture efficiency of RNA on our proposed microdevice. 81% of RNAs were successfully captured and purified. Interestingly, the use of the RT-PCR cocktail itself as an elution solution resulted in a 76% capture yield. Furthermore, we successfully performed RNA purification from the clinical nasopharyngeal swabs to identify the subtype of the influenza A virus. This platform provides high potential for the direct integration of the sample pretreatment microdevice into the downstream micro-PCR unit to create a total genetic analysis microsystem.
Collapse
Affiliation(s)
- Jae Hwan Jung
- Department of Chemical and Biomolecular Engineering, BK21 Program and Institute for the BioCentury, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 305-701, Republic of Korea
| | | | | | | |
Collapse
|
39
|
Skinner JP, Swift KM, Ruan Q, Perfetto S, Gratton E, Tetin SY. Simplified confocal microscope for counting particles at low concentrations. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2013; 84:074301. [PMID: 23902088 PMCID: PMC3724729 DOI: 10.1063/1.4812782] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
We describe a compact scanning confocal fluorescence microscope capable of detecting particles concentrations less than 100 particles∕ml in ~15 min. The system mechanically moves a cuvette containing ~3 ml of sample. A relatively large confocal volume is observed within the cuvette using a 1 mm pinhole in front of a detection PMT. Due to the motion of the sample, particles traverse the confocal volume quickly, and analysis by pattern recognition qualifies spikes in the emission intensity data and counts them as events. We show linearity of detection as a function of concentration and also characterize statistical behavior of the instrument. We calculate a detection sensitivity of the system using 3 μm fluorescent microspheres to be 5 particles/ml. Furthermore, to demonstrate biological application, we performed a dilution series to quantify stained E. coli and yeast cells. We counted E. coli cells at a concentration as low as 30 cells∕ml in 10 min/sample.
Collapse
Affiliation(s)
- Joseph P Skinner
- Diagnostics Research, Abbott Diagnostics Division, Abbott Park, Illinois 60064, USA
| | | | | | | | | | | |
Collapse
|
40
|
Ban E, Song EJ. Recent developments and applications of capillary electrophoresis with laser-induced fluorescence detection in biological samples. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 929:180-6. [DOI: 10.1016/j.jchromb.2013.04.028] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2012] [Revised: 04/18/2013] [Accepted: 04/20/2013] [Indexed: 12/15/2022]
|
41
|
Verbarg J, Plath WD, Shriver-Lake LC, Howell PB, Erickson JS, Golden JP, Ligler FS. Catch and release: integrated system for multiplexed detection of bacteria. Anal Chem 2013; 85:4944-50. [PMID: 23631439 DOI: 10.1021/ac303801v] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
An integrated system with automated immunomagnetic separation and processing of fluidic samples was demonstrated for multiplexed optical detection of bacterial targets. Mixtures of target-specific magnetic bead sets were processed in the NRL MagTrap with the aid of rotating magnet arrays that entrapped and moved the beads within the channel during reagent processing. Processing was performed in buffer and human serum matrixes with 10-fold dilutions in the range of 10(2)-10(6) cells/mL of target bacteria. Reversal of magnets' rotation post-processing released the beads back into the flow and moved them into the microflow cytometer for optical interrogation. Identification of the beads and the detection of PE fluorescence were performed simultaneously for multiplexed detection. Multiplexing was performed with specifically targeted bead sets to detect E. coli 0157.H7, Salmonella Common Structural Antigen, Listeria sp., and Shigella sp., dose-response curves were obtained, and limits of detection were calculated for each target in the buffer and clinical matrix. Additional tests demonstrated the potential for using the MagTrap to concentrate target from larger volumes of sample prior to the addition of assay reagents.
Collapse
Affiliation(s)
- Jasenka Verbarg
- Center for Bio/Molecular Science & Engineering, Naval Research Laboratory, Washington, DC 20375, United States
| | | | | | | | | | | | | |
Collapse
|
42
|
Ríos Á, Ríos Á, Zougagh M, Zougagh M. Sample preparation for micro total analytical systems (μ-TASs). Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2012.12.009] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
43
|
|
44
|
Jensen EC, Stockton AM, Chiesl TN, Kim J, Bera A, Mathies RA. Digitally programmable microfluidic automaton for multiscale combinatorial mixing and sample processing. LAB ON A CHIP 2013; 13:288-96. [PMID: 23172232 PMCID: PMC3568922 DOI: 10.1039/c2lc40861a] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
A digitally programmable microfluidic Automaton consisting of a 2-dimensional array of pneumatically actuated microvalves is programmed to perform new multiscale mixing and sample processing operations. Large (μL-scale) volume processing operations are enabled by precise metering of multiple reagents within individual nL-scale valves followed by serial repetitive transfer to programmed locations in the array. A novel process exploiting new combining valve concepts is developed for continuous rapid and complete mixing of reagents in less than 800 ms. Mixing, transfer, storage, and rinsing operations are implemented combinatorially to achieve complex assay automation protocols. The practical utility of this technology is demonstrated by performing automated serial dilution for quantitative analysis as well as the first demonstration of on-chip fluorescent derivatization of biomarker targets (carboxylic acids) for microchip capillary electrophoresis on the Mars Organic Analyzer. A language is developed to describe how unit operations are combined to form a microfluidic program. Finally, this technology is used to develop a novel microfluidic 6-sample processor for combinatorial mixing of large sets (>2(6) unique combinations) of reagents. The digitally programmable microfluidic Automaton is a versatile programmable sample processor for a wide range of process volumes, for multiple samples, and for different types of analyses.
Collapse
Affiliation(s)
- Erik C. Jensen
- Biophysics Graduate Group, University of California, Berkeley, CA, USA
| | | | - Thomas N. Chiesl
- Department of Chemistry, University of California, Berkeley, CA, USA
| | - Jungkyu Kim
- Department of Chemistry, University of California, Berkeley, CA, USA
| | | | - Richard A. Mathies
- Biophysics Graduate Group, University of California, Berkeley, CA, USA
- Department of Chemistry, University of California, Berkeley, CA, USA
- ; Fax: +1 (510) 642-3599; Tel: +1 (510) 642-4192
| |
Collapse
|
45
|
Kim YT, Choi JY, Chen Y, Seo TS. Integrated slidable and valveless polymerase chain reaction–capillary electrophoresis microdevice for pathogen detection. RSC Adv 2013. [DOI: 10.1039/c3ra41402g] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
46
|
Apori AA, Herr AE. Chip-based immunoassays. Methods Mol Biol 2013; 919:233-248. [PMID: 22976105 DOI: 10.1007/978-1-62703-029-8_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Microfluidic immunoassay techniques offer advantages in speed, automation, and portability over -bench-top gold standard counterparts. In particular, on-chip immunosubtraction is a rapid homogeneous immunoassay used for reporting both protein native mobility and binding specificity. Immunosubtraction is performed by removing antibody-bound target proteins from electrophoretic detection via a size-based exclusion filter, while unbound nontarget proteins are able to pass through the filter for downstream detection. Immunosubtraction is achieved on-chip by fabrication of discrete patterned polyacrylamide (PA) gel regions. Additionally, PA gel regions are used to define on-chip sample preparation regions for protein enrichment, fluorescent labeling, and antibody-target binding prior to immunosubtraction. Here we describe the immunosubtraction device fabrication technique as well as the electrophoretic assay protocol for determining target protein mobility and binding specificity within complex biological samples including cerebrospinal fluid.
Collapse
Affiliation(s)
- Akwasi A Apori
- Department of Bioengineering, University of California Berkeley, Berkeley, CA, USA
| | | |
Collapse
|
47
|
Choi JY, Kim YT, Byun JY, Ahn J, Chung S, Gweon DG, Kim MG, Seo TS. An integrated allele-specific polymerase chain reaction-microarray chip for multiplex single nucleotide polymorphism typing. LAB ON A CHIP 2012; 12:5146-5154. [PMID: 23037501 DOI: 10.1039/c2lc40878c] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
An integrated allele-specific polymerase chain reaction (AS PCR) and microarray chip has been developed for multiplex single nucleotide polymorphism (SNP) typing on a portable genetic analyzer instrumentation. We applied the integrated PCR-microarray system for on-site Hanwoo (Korean indigenous beef cattle) identification. Eleven sets of primers were designed, among which ten sets of primers targeted ten SNP loci to discriminate Hanwoo from the imported beef cattle and one primer set was used as a positive PCR control. The AS PCR for multiplex SNP typing was conducted on a glass-based microchip consisting of four layers: a microchannel plate for microfluidic control, a Pt-electrode plate for a resistance temperature detector (RTD), a poly(dimethylsiloxane) (PDMS) membrane and a manifold glass for micropump and microvalve function. The resultant AS PCR products were mixed with a hybridization buffer in a micromixer channel through the micropumping operation, and then the microarray assay was performed in the downstream process. Eleven duplicate probes were spotted in a glass slide, which was connected at the end of the micromixer channel unit. When the mixed solution was injected into the disposable microarray chip, pneumatically actuated micropumping was executed to speed up the hybridization process by inducing the convective flow. The fluorescence signals on each spot were monitored by a miniaturized fluorescence scanner, and the Hanwoo was verified by detecting the number of fluorescent spots with three or fewer among eleven. An integrated portable PCR-microarray genetic analysis microsystem was first demonstrated for rapid, accurate, and on-site multiplex SNP typing to differentiate animal species.
Collapse
Affiliation(s)
- Jong Young Choi
- Department of Chemical and Biomolecular Engineering (BK21 Program), Korea Advanced Institute of Science and Technology, Daejeon 305-701, Korea
| | | | | | | | | | | | | | | |
Collapse
|
48
|
Hilton JP, Nguyen T, Barbu M, Pei R, Stojanovic M, Lin Q. Bead-based polymerase chain reaction on a microchip. MICROFLUIDICS AND NANOFLUIDICS 2012; 13:749-760. [PMID: 33664642 PMCID: PMC7929480 DOI: 10.1007/s10404-012-0993-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
We present a bead-based approach to microfluidic polymerase chain reaction (PCR), enabling fluorescent detection and sample conditioning in a single microchamber. Bead-based PCR, while not extensively investigated in microchip format, has been used in a variety of bioanalytical applications in recent years. We leverage the ability of bead-based PCR to accumulate fluorescent labels following DNA amplification to explore a novel DNA detection scheme on a microchip. The microchip uses an integrated microheater and temperature sensor for rapid control of thermal cycling temperatures, while the sample is held in a microchamber fabricated from (poly)dimethylsiloxane and coated with Parylene. The effects of key bead-based PCR parameters, including annealing temperature and concentration of microbeads in the reaction mixture, are studied to achieve optimized device sensitivity and detection time. The device is capable of detecting a synthetically prepared section of the Bordetella pertussis genome in as few as 10 temperature cycles with times as short as 15 min. We then demonstrate the use of the procedure in an integrated device; capturing, amplifying, detecting, and purifying template DNA in a single microfluidic chamber. These results show that this method is an effective method of DNA detection which is easily integrated in a microfluidic device to perform additional steps such as sample pre-conditioning.
Collapse
Affiliation(s)
- John P Hilton
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA
| | - ThaiHuu Nguyen
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA
| | - Mihaela Barbu
- Division of Clinical Pharmacology and Experimental Therapeutics, Department of Medicine, Columbia University, New York, NY 10032, USA
| | - Renjun Pei
- Division of Clinical Pharmacology and Experimental Therapeutics, Department of Medicine, Columbia University, New York, NY 10032, USA
| | - Milan Stojanovic
- Division of Clinical Pharmacology and Experimental Therapeutics, Department of Medicine, Columbia University, New York, NY 10032, USA
| | - Qiao Lin
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA
| |
Collapse
|
49
|
Nge PN, Pagaduan JV, Yu M, Woolley AT. Microfluidic chips with reversed-phase monoliths for solid phase extraction and on-chip labeling. J Chromatogr A 2012; 1261:129-35. [PMID: 22995197 PMCID: PMC3463737 DOI: 10.1016/j.chroma.2012.08.095] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2012] [Revised: 08/28/2012] [Accepted: 08/29/2012] [Indexed: 01/13/2023]
Abstract
The integration of sample preparation methods into microfluidic devices provides automation necessary for achieving complete micro total analysis systems. We have developed a technique that combines on-chip sample enrichment with fluorescence labeling and purification. Polymer monoliths made from butyl methacrylate were fabricated in cyclic olefin copolymer microdevices and used for solid phase extraction. We studied the retention of fluorophores, amino acids and proteins on these columns. The retained samples were subsequently labeled with both Alexa Fluor 488 and Chromeo P503, and unreacted dye was rinsed off the column before sample elution. Additional purification was obtained from the differential retention of proteins and fluorescent labels. A linear relation between the eluted peak areas and concentrations of on-chip labeled heat shock protein 90 samples demonstrated the utility of this method for on-chip quantitation. Our fast and simple method of simultaneously concentrating and labeling samples on-chip is compatible with miniaturization and desirable for automated analysis.
Collapse
Affiliation(s)
- Pamela N. Nge
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602
| | - Jayson V. Pagaduan
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602
| | - Ming Yu
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602
| | - Adam T. Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602
| |
Collapse
|
50
|
Jangam SR, Agarwal AK, Sur K, Kelso DM. A point-of-care PCR test for HIV-1 detection in resource-limited settings. Biosens Bioelectron 2012. [PMID: 23202333 DOI: 10.1016/j.bios.2012.10.024] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
A low-cost, fully integrated sample-to-answer, quantitative PCR (qPCR) system that can be used for detection of HIV-1 proviral DNA in infants at the point-of-care in resource-limited settings has been developed and tested. The system is based on a novel DNA extraction method, which uses a glass fiber membrane, a disposable assay card that includes on-board reagent storage, provisions for thermal cycling and fluorescence detection, and a battery-operated portable analyzer. The system is capable of automated PCR mix assembly using a novel reagent delivery system and performing qPCR. HIV-1 and internal control targets are detected using two spectrally separated fluorophores, FAM and Quasar 670. In this report, a proof-of-concept of the platform is demonstrated. Initial results with whole blood demonstrate that the test is capable of detecting HIV-1 in blood samples containing greater than 5000 copies of HIV-1. In resource-limited settings, a point-of-care HIV-1 qPCR test would greatly increase the number of test results that reach the infants caregivers, allowing them to pursue anti-retroviral therapy.
Collapse
Affiliation(s)
- Sujit R Jangam
- Center for Innovation in Global Health Technologies, Biomedical Engineering, 2145 Sheridan Road E310, Northwestern University, Evanston, IL 60208-3107, USA.
| | | | | | | |
Collapse
|