1
|
Madadelahi M, Agarwal R, Martinez-Chapa SO, Madou MJ. A roadmap to high-speed polymerase chain reaction (PCR): COVID-19 as a technology accelerator. Biosens Bioelectron 2024; 246:115830. [PMID: 38039729 DOI: 10.1016/j.bios.2023.115830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 11/07/2023] [Accepted: 11/08/2023] [Indexed: 12/03/2023]
Abstract
The limit of detection (LOD), speed, and cost of crucial COVID-19 diagnostic tools, including lateral flow assays (LFA), enzyme-linked immunosorbent assays (ELISA), and polymerase chain reactions (PCR), have all improved because of the financial and governmental support for the epidemic. The most notable improvement in overall efficiency among them has been seen with PCR. Its significance for human health increased during the COVID-19 pandemic, when it emerged as the commonly used approach for identifying the virus. However, because of problems with speed, complexity, and expense, PCR deployment in point-of-care settings continues to be difficult. Microfluidic platforms offer a promising solution by enabling the development of smaller, more affordable, and faster PCR systems. In this review, we delve into the engineering challenges associated with the advancement of high-speed microfluidic PCR equipment. We introduce criteria that facilitate the evaluation and comparison of factors such as speed, LOD, cycling efficiency, and multiplexing capacity, considering sample volume, fluidics, PCR reactor geometry and materials, as well as heating/cooling methods. We also provide a comprehensive list of commercially available PCR devices and conclude with projections and a discussion regarding the current obstacles that need to be addressed in order to progress further in this field.
Collapse
Affiliation(s)
- Masoud Madadelahi
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, 64849, NL, Mexico; Department of Mechanical Engineering, Isfahan University of Technology, Isfahan, 84156-83111, Iran.
| | - Rahul Agarwal
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, 64849, NL, Mexico
| | | | - Marc J Madou
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, 64849, NL, Mexico; Autonomous Medical Devices Incorporated (AMDI), Santa Ana, CA, 92704, USA.
| |
Collapse
|
2
|
Madadelahi M, Madou MJ. Rational PCR Reactor Design in Microfluidics. MICROMACHINES 2023; 14:1533. [PMID: 37630070 PMCID: PMC10456396 DOI: 10.3390/mi14081533] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2023] [Revised: 07/07/2023] [Accepted: 07/13/2023] [Indexed: 08/27/2023]
Abstract
Limit of detection (LOD), speed, and cost for some of the most important diagnostic tools, i.e., lateral flow assays (LFA), enzyme-linked immunosorbent assays (ELISA), and polymerase chain reaction (PCR), all benefited from both the financial and regulatory support brought about by the pandemic. From those three, PCR has gained the most in overall performance. However, implementing PCR in point of care (POC) settings remains challenging because of its stringent requirements for a low LOD, multiplexing, accuracy, selectivity, robustness, and cost. Moreover, from a clinical point of view, it has become very desirable to attain an overall sample-to-answer time (t) of 10 min or less. Based on those POC requirements, we introduce three parameters to guide the design towards the next generation of PCR reactors: the overall sample-to-answer time (t); lambda (λ), a measure that sets the minimum number of copies required per reactor volume; and gamma (γ), the system's thermal efficiency. These three parameters control the necessary sample volume, the number of reactors that are feasible (for multiplexing), the type of fluidics, the PCR reactor shape, the thermal conductivity, the diffusivity of the materials used, and the type of heating and cooling systems employed. Then, as an illustration, we carry out a numerical simulation of temperature changes in a PCR device, discuss the leading commercial and RT-qPCR contenders under development, and suggest approaches to achieve the PCR reactor for RT-qPCR of the future.
Collapse
Affiliation(s)
- Masoud Madadelahi
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey 64849, NL, Mexico;
| | - Marc J. Madou
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey 64849, NL, Mexico;
- Autonomous Medical Devices Incorporated (AMDI), Santa Ana, CA 92704, USA
| |
Collapse
|
3
|
Bruijns B, Knotter J, Tiggelaar R. A Systematic Review on Commercially Available Integrated Systems for Forensic DNA Analysis. SENSORS (BASEL, SWITZERLAND) 2023; 23:1075. [PMID: 36772114 PMCID: PMC9919030 DOI: 10.3390/s23031075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 01/11/2023] [Accepted: 01/12/2023] [Indexed: 06/18/2023]
Abstract
This systematic review describes and discusses three commercially available integrated systems for forensic DNA analysis, i.e., ParaDNA, RapidHIT, and ANDE. A variety of aspects, such as performance, time-to-result, ease-of-use, portability, and costs (per analysis run) of these three (modified) rapid DNA analysis systems, are considered. Despite their advantages and developmental progress, major steps still have to be made before rapid systems can be broadly applied at crime scenes for full DNA profiling. Aspects in particular that need (further) improvement are portability, performance, the possibility to analyze a (wider) variety of (complex) forensic samples, and (cartridge) costs. Moreover, steps forward regarding ease-of-use and time-to-result will benefit the broader use of commercial rapid DNA systems. In fact, it would be a profit if rapid DNA systems could be used for full DNA profile generation as well as indicative analyses that can give direction to forensic investigators which will speed up investigations.
Collapse
Affiliation(s)
- Brigitte Bruijns
- Technologies for Criminal Investigations, Saxion University of Applied Sciences, M.H. Tromplaan 28, 7513 AB Enschede, The Netherlands
- Politieacademie, Arnhemseweg 348, 7334 AC Apeldoorn, The Netherlands
| | - Jaap Knotter
- Technologies for Criminal Investigations, Saxion University of Applied Sciences, M.H. Tromplaan 28, 7513 AB Enschede, The Netherlands
- Politieacademie, Arnhemseweg 348, 7334 AC Apeldoorn, The Netherlands
| | - Roald Tiggelaar
- NanoLab Cleanroom, MESA+ Institute, University of Twente, Drienerlolaan 5, 7500 AE Enschede, The Netherlands
| |
Collapse
|
4
|
Chen S, Sun Y, Fan F, Chen S, Zhang Y, Zhang Y, Meng X, Lin JM. Present status of microfluidic PCR chip in nucleic acid detection and future perspective. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
5
|
Tzivelekis C, Sgardelis P, Waldron K, Whalley R, Huo D, Dalgarno K. Fabrication routes via projection stereolithography for 3D-printing of microfluidic geometries for nucleic acid amplification. PLoS One 2020; 15:e0240237. [PMID: 33112867 PMCID: PMC7592796 DOI: 10.1371/journal.pone.0240237] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 09/22/2020] [Indexed: 12/19/2022] Open
Abstract
Digital Light Processing (DLP) stereolithography (SLA) as a high-resolution 3D printing process offers a low-cost alternative for prototyping of microfluidic geometries, compared to traditional clean-room and workshop-based methods. Here, we investigate DLP-SLA printing performance for the production of micro-chamber chip geometries suitable for Polymerase Chain Reaction (PCR), a key process in molecular diagnostics to amplify nucleic acid sequences. A DLP-SLA fabrication protocol for printed micro-chamber devices with monolithic micro-channels is developed and evaluated. Printed devices were post-processed with ultraviolet (UV) light and solvent baths to reduce PCR inhibiting residuals and further treated with silane coupling agents to passivate the surface, thereby limiting biomolecular adsorption occurences during the reaction. The printed devices were evaluated on a purpose-built infrared (IR) mediated PCR thermocycler. Amplification of 75 base pair long target sequences from genomic DNA templates on fluorosilane and glass modified chips produced amplicons consistent with the control reactions, unlike the non-silanized chips that produced faint or no amplicon. The results indicated good functionality of the IR thermocycler and good PCR compatibility of the printed and silanized SLA polymer. Based on the proposed methods, various microfluidic designs and ideas can be validated in-house at negligible costs without the requirement of tool manufacturing and workshop or clean-room access. Additionally, the versatile chemistry of 3D printing resins enables customised surface properties adding significant value to the printed prototypes. Considering the low setup and unit cost, design flexibility and flexible resin chemistries, DLP-SLA is anticipated to play a key role in future prototyping of microfluidics, particularly in the fields of research biology and molecular diagnostics. From a system point-of-view, the proposed method of thermocycling shows promise for portability and modular integration of funcitonalitites for diagnostic or research applications that utilize nucleic acid amplification technology.
Collapse
Affiliation(s)
| | - Pavlos Sgardelis
- School of Engineering, Newcastle University, Newcastle, United Kingdom
| | - Kevin Waldron
- Institute for Cell and Molecular Biosciences, Newcastle University, Newcastle, United Kingdom
| | - Richard Whalley
- School of Engineering, Newcastle University, Newcastle, United Kingdom
| | - Dehong Huo
- School of Engineering, Newcastle University, Newcastle, United Kingdom
| | - Kenny Dalgarno
- School of Engineering, Newcastle University, Newcastle, United Kingdom
| |
Collapse
|
6
|
Kopparthy VL, Crews ND. A versatile oscillating‐flow microfluidic PCR system utilizing a thermal gradient for nucleic acid analysis. Biotechnol Bioeng 2020; 117:1525-1532. [DOI: 10.1002/bit.27278] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Revised: 12/20/2019] [Accepted: 01/14/2020] [Indexed: 11/10/2022]
Affiliation(s)
- Varun L. Kopparthy
- Center for Biomedical Engineering and Rehabilitation Science (CBERS) Louisiana Tech University Ruston Louisiana
- Present address: Cleveland Clinic Cleveland Ohio
| | - Niel D. Crews
- Institute for Micromanufacturing (IfM) Louisiana Tech University Ruston Louisiana
| |
Collapse
|
7
|
Weidmann M, Faye O, Faye O, Abd El Wahed A, Patel P, Batejat C, Manugerra JC, Adjami A, Niedrig M, Hufert FT, Sall AA. Development of Mobile Laboratory for Viral Hemorrhagic Fever Detection in Africa. J Infect Dis 2019; 218:1622-1630. [PMID: 29917112 PMCID: PMC6173574 DOI: 10.1093/infdis/jiy362] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2018] [Accepted: 06/12/2018] [Indexed: 11/22/2022] Open
Abstract
Background A mobile laboratory transportable on commercial flights was developed to enable local response to viral hemorrhagic fever outbreaks. Methods The development progressed from use of mobile real-time reverse-transcription polymerase chain reaction to mobile real-time recombinase polymerase amplification. In this study, we describe various stages of the mobile laboratory development. Results A brief overview of mobile laboratory deployments, which culminated in the first on-site detection of Ebola virus disease (EVD) in March 2014, and their successful use in a campaign to roll back EVD cases in Conakry in the West Africa Ebola virus outbreak are described. Conclusions The developed mobile laboratory successfully enabled local teams to perform rapid disgnostic testing for viral hemorrhagic fever.
Collapse
Affiliation(s)
- Manfred Weidmann
- Institute of Aquaculture, University of Stirling, Scotland, United Kingdom
- Correspondence: M. Weidmann, Dr. rer. nat., University of Stirling, Institute of Aquaculture, Stirling FK9 4LA, Scotland, United Kingdom ()
| | - Ousmane Faye
- Arbovirus Unit, Pasteur Institute, Dakar, Senegal
| | - Oumar Faye
- Arbovirus Unit, Pasteur Institute, Dakar, Senegal
| | - Ahmed Abd El Wahed
- Unit of Infection Models, German Primate Center, Goettingen, Germany
- Division of Microbiology and Animal Hygiene, University of Goettingen, Germany
| | | | - Christophe Batejat
- Laboratory for Urgent Response to Biological Threats (CIBU), Environment and Infectious Risks Unit, Institut Pasteur, Paris, France
| | - Jean Claude Manugerra
- Laboratory for Urgent Response to Biological Threats (CIBU), Environment and Infectious Risks Unit, Institut Pasteur, Paris, France
| | - Aimee Adjami
- Multi Disease Surveillance Centre WHO, Ougadougou, Burkina Faso
| | | | - Frank T Hufert
- Institute of Microbiology and Virology, Brandenburg Medical School Fontane (and Member of the Faculty of Environment and Natural Sciences of B-TU Senftenberg site), Senftenberg, Brandenburg, Germany
| | | |
Collapse
|
8
|
Cyclic Olefin Copolymer Microfluidic Devices for Forensic Applications. BIOSENSORS-BASEL 2019; 9:bios9030085. [PMID: 31277382 PMCID: PMC6784357 DOI: 10.3390/bios9030085] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 06/28/2019] [Accepted: 07/03/2019] [Indexed: 01/16/2023]
Abstract
Microfluidic devices offer important benefits for forensic applications, in particular for fast tests at a crime scene. A large portion of forensic applications require microfluidic chip material to show compatibility with biochemical reactions (such as amplification reactions), and to have high transparency in the visible region and high chemical resistance. Also, preferably, manufacturing should be simple. The characteristic properties of cyclic olefin copolymer (COC) fulfills these requirements and offers new opportunities for the development of new forensic tests. In this work, the versatility of COC as material for lab-on-a-chip (LOC) systems in forensic applications has been explored by realizing two proof-of-principle devices. Chemical resistance and optical transparency were investigated for the development of an on-chip presumptive color test to indicate the presence of an illicit substance through applying absorption spectroscopy. Furthermore, the compatibility of COC with a DNA amplification reaction was verified by performing an on-chip multiple displacement amplification (MDA) reaction.
Collapse
|
9
|
Lee NY. A review on microscale polymerase chain reaction based methods in molecular diagnosis, and future prospects for the fabrication of fully integrated portable biomedical devices. Mikrochim Acta 2018; 185:285. [PMID: 29736588 DOI: 10.1007/s00604-018-2791-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2018] [Accepted: 04/05/2018] [Indexed: 02/06/2023]
Abstract
Since the advent of microfabrication technology and soft lithography, the lab-on-a-chip concept has emerged as a state-of-the-art miniaturized tool for conducting the multiple functions associated with micro total analyses of nucleic acids, in series, in a seamless manner with a miniscule volume of sample. The enhanced surface-to-volume ratio inside a microchannel enables fast reactions owing to increased heat dissipation, allowing rapid amplification. For this reason, PCR has been one of the first applications to be miniaturized in a portable format. However, the nature of the basic working principle for microscale PCR, such as the complicated temperature controls and use of a thermal cycler, has hindered its total integration with other components into a micro total analyses systems (μTAS). This review (with 179 references) surveys the diverse forms of PCR microdevices constructed on the basis of different working principles and evaluates their performances. The first two main sections cover the state-of-the-art in chamber-type PCR microdevices and in continuous-flow PCR microdevices. Methods are then discussed that lead to microdevices with upstream sample purification and downstream detection schemes, with a particular focus on rapid on-site detection of foodborne pathogens. Next, the potential for miniaturizing and automating heaters and pumps is examined. The review concludes with sections on aspects of complete functional integration in conjunction with nanomaterial based sensing, a discussion on future prospects, and with conclusions. Graphical abstract In recent years, thermocycler-based PCR systems have been miniaturized to palm-sized, disposable polymer platforms. In addition, operational accessories such as heaters and mechanical pumps have been simplified to realize semi-automatted stand-alone portable biomedical diagnostic microdevices that are directly applicable in the field. This review summarizes the progress made and the current state of this field.
Collapse
Affiliation(s)
- Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| |
Collapse
|
10
|
Microfluidic Devices for Forensic DNA Analysis: A Review. BIOSENSORS-BASEL 2016; 6:bios6030041. [PMID: 27527231 PMCID: PMC5039660 DOI: 10.3390/bios6030041] [Citation(s) in RCA: 75] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Revised: 07/07/2016] [Accepted: 07/25/2016] [Indexed: 12/16/2022]
Abstract
Microfluidic devices may offer various advantages for forensic DNA analysis, such as reduced risk of contamination, shorter analysis time and direct application at the crime scene. Microfluidic chip technology has already proven to be functional and effective within medical applications, such as for point-of-care use. In the forensic field, one may expect microfluidic technology to become particularly relevant for the analysis of biological traces containing human DNA. This would require a number of consecutive steps, including sample work up, DNA amplification and detection, as well as secure storage of the sample. This article provides an extensive overview of microfluidic devices for cell lysis, DNA extraction and purification, DNA amplification and detection and analysis techniques for DNA. Topics to be discussed are polymerase chain reaction (PCR) on-chip, digital PCR (dPCR), isothermal amplification on-chip, chip materials, integrated devices and commercially available techniques. A critical overview of the opportunities and challenges of the use of chips is discussed, and developments made in forensic DNA analysis over the past 10–20 years with microfluidic systems are described. Areas in which further research is needed are indicated in a future outlook.
Collapse
|
11
|
Guzman NA, Guzman DE. An emerging micro-scale immuno-analytical diagnostic tool to see the unseen. Holding promise for precision medicine and P4 medicine. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1021:14-29. [DOI: 10.1016/j.jchromb.2015.11.026] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 11/15/2015] [Accepted: 11/17/2015] [Indexed: 01/10/2023]
|
12
|
Strachan BC, Sloane HS, Houpt E, Lee JC, Miranian DC, Li J, Nelson DA, Landers JP. A simple integrated microfluidic device for the multiplexed fluorescence-free detection of Salmonella enterica. Analyst 2015; 141:947-55. [PMID: 26658961 DOI: 10.1039/c5an01969a] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Rapid, inexpensive and simplistic nucleic acid testing (NAT) is pivotal in delivering biotechnology solutions at the point-of-care (POC). We present a poly(methylmethacrylate) (PMMA) microdevice where on-board infrared-mediated PCR amplification is seamlessly integrated with a particle-based, visual DNA detection for specific detection of bacterial targets in less than 35 minutes. Fluidic control is achieved using a capillary burst valve laser-ablated in a novel manner to confine the PCR reagents to a chamber during thermal cycling, and a manual torque-actuated pressure system to mobilize the fluid from the PCR chamber to the detection reservoir containing oligonucleotide-adducted magnetic particles. Interaction of amplified products specific to the target organism with the beads in a rotating magnetic field allows for near instantaneous (<30 s) detection based on hybridization-induced aggregation (HIA) of the particles and simple optical analysis. The integration of PCR with this rapid, sequence-specific DNA detection method on a single microdevice presents the possibility of creating POC NAT systems that are low cost, easy-to-use, and involve minimal external hardware.
Collapse
Affiliation(s)
- Briony C Strachan
- Dept of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904, USA.
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Bartsch MS, Edwards HS, Lee D, Moseley CE, Tew KE, Renzi RF, Van de Vreugde JL, Kim H, Knight DL, Sinha A, Branda SS, Patel KD. The rotary zone thermal cycler: a low-power system enabling automated rapid PCR. PLoS One 2015; 10:e0118182. [PMID: 25826708 PMCID: PMC4380418 DOI: 10.1371/journal.pone.0118182] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Accepted: 01/09/2015] [Indexed: 12/17/2022] Open
Abstract
Advances in molecular biology, microfluidics, and laboratory automation continue to expand the accessibility and applicability of these methods beyond the confines of conventional, centralized laboratory facilities and into point of use roles in clinical, military, forensic, and field-deployed applications. As a result, there is a growing need to adapt the unit operations of molecular biology (e.g., aliquoting, centrifuging, mixing, and thermal cycling) to compact, portable, low-power, and automation-ready formats. Here we present one such adaptation, the rotary zone thermal cycler (RZTC), a novel wheel-based device capable of cycling up to four different fixed-temperature blocks into contact with a stationary 4-microliter capillary-bound sample to realize 1-3 second transitions with steady state heater power of less than 10 W. We demonstrate the utility of the RZTC for DNA amplification as part of a highly integrated rotary zone PCR (rzPCR) system that uses low-volume valves and syringe-based fluid handling to automate sample loading and unloading, thermal cycling, and between-run cleaning functionalities in a compact, modular form factor. In addition to characterizing the performance of the RZTC and the efficacy of different online cleaning protocols, we present preliminary results for rapid single-plex PCR, multiplex short tandem repeat (STR) amplification, and second strand cDNA synthesis.
Collapse
Affiliation(s)
- Michael S. Bartsch
- Sandia National Laboratories, Livermore, CA, United States of America
- * E-mail:
| | | | - Daniel Lee
- Sandia National Laboratories, Livermore, CA, United States of America
| | | | - Karen E. Tew
- Sandia National Laboratories, Livermore, CA, United States of America
| | - Ronald F. Renzi
- Sandia National Laboratories, Livermore, CA, United States of America
| | | | - Hanyoup Kim
- Sandia National Laboratories, Livermore, CA, United States of America
| | | | - Anupama Sinha
- Sandia National Laboratories, Livermore, CA, United States of America
| | - Steven S. Branda
- Sandia National Laboratories, Livermore, CA, United States of America
| | - Kamlesh D. Patel
- Sandia National Laboratories, Livermore, CA, United States of America
| |
Collapse
|
14
|
Raising the shields: PCR in the presence of metallic surfaces protected by tailor-made coatings. Colloids Surf B Biointerfaces 2014; 122:576-582. [DOI: 10.1016/j.colsurfb.2014.07.035] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2014] [Revised: 07/22/2014] [Accepted: 07/22/2014] [Indexed: 11/21/2022]
|
15
|
Reinholt SJ, Behrent A, Greene C, Kalfe A, Baeumner AJ. Isolation and amplification of mRNA within a simple microfluidic lab on a chip. Anal Chem 2014; 86:849-56. [PMID: 24328414 PMCID: PMC3923508 DOI: 10.1021/ac403417z] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The major modules for realizing molecular biological assays in a micro-total analysis system (μTAS) were developed for the detection of pathogenic organisms. The specific focus was the isolation and amplification of eukaryotic mRNA within a simple, single-channel device for very low RNA concentrations that could then be integrated with detection modules. The hsp70 mRNA from Cryptosporidium parvum was used as a model analyte. Important points of study were surface chemistries within poly(methyl methacrylate) (PMMA) microfluidic channels that enabled specific and sensitive mRNA isolation and amplification reactions for very low mRNA concentrations. Optimal conditions were achieved when the channel surface was carboxylated via UV/ozone treatment followed by the immobilization of polyamidoamine (PAMAM) dendrimers on the surface, thus increasing the immobilization efficiency of the thymidine oligonucleotide, oligo(dT)25, and providing a reliable surface for the amplification reaction, importantly, without the need for blocking agents. Additional chemical modifications of the remaining active surface groups were studied to avoid nonspecific capturing of nucleic acids and hindering of the mRNA amplification at low RNA concentrations. Amplification of the mRNA was accomplished using nucleic acid sequence-based amplification (NASBA), an isothermal, primer-dependent technique. Positive controls consisting of previously generated NASBA amplicons could be diluted 10(15) fold and still result in successful on-chip reamplification. Finally, the successful isolation and amplification of mRNA from as few as 30 C. parvum oocysts was demonstrated directly on-chip and compared to benchtop devices. This is the first proof of successful mRNA isolation and NASBA-based amplification of mRNA within a simple microfluidic device in relevant analytical volumes.
Collapse
Affiliation(s)
- Sarah J. Reinholt
- Department of Biological and Environmental Engineering, Ithaca, NY, 14853, USA
| | - Arne Behrent
- Department of Biological and Environmental Engineering, Ithaca, NY, 14853, USA
| | - Cassandra Greene
- Department of Biological and Environmental Engineering, Ithaca, NY, 14853, USA
| | - Ayten Kalfe
- Department of Biological and Environmental Engineering, Ithaca, NY, 14853, USA
| | - Antje J. Baeumner
- Department of Biological and Environmental Engineering, Ithaca, NY, 14853, USA
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Germany
| |
Collapse
|
16
|
Wu J, Kodzius R, Cao W, Wen W. Extraction, amplification and detection of DNA in microfluidic chip-based assays. Mikrochim Acta 2013. [DOI: 10.1007/s00604-013-1140-2] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
17
|
Hilton JP, Nguyen T, Barbu M, Pei R, Stojanovic M, Lin Q. Bead-based polymerase chain reaction on a microchip. MICROFLUIDICS AND NANOFLUIDICS 2012; 13:749-760. [PMID: 33664642 PMCID: PMC7929480 DOI: 10.1007/s10404-012-0993-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
We present a bead-based approach to microfluidic polymerase chain reaction (PCR), enabling fluorescent detection and sample conditioning in a single microchamber. Bead-based PCR, while not extensively investigated in microchip format, has been used in a variety of bioanalytical applications in recent years. We leverage the ability of bead-based PCR to accumulate fluorescent labels following DNA amplification to explore a novel DNA detection scheme on a microchip. The microchip uses an integrated microheater and temperature sensor for rapid control of thermal cycling temperatures, while the sample is held in a microchamber fabricated from (poly)dimethylsiloxane and coated with Parylene. The effects of key bead-based PCR parameters, including annealing temperature and concentration of microbeads in the reaction mixture, are studied to achieve optimized device sensitivity and detection time. The device is capable of detecting a synthetically prepared section of the Bordetella pertussis genome in as few as 10 temperature cycles with times as short as 15 min. We then demonstrate the use of the procedure in an integrated device; capturing, amplifying, detecting, and purifying template DNA in a single microfluidic chamber. These results show that this method is an effective method of DNA detection which is easily integrated in a microfluidic device to perform additional steps such as sample pre-conditioning.
Collapse
Affiliation(s)
- John P Hilton
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA
| | - ThaiHuu Nguyen
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA
| | - Mihaela Barbu
- Division of Clinical Pharmacology and Experimental Therapeutics, Department of Medicine, Columbia University, New York, NY 10032, USA
| | - Renjun Pei
- Division of Clinical Pharmacology and Experimental Therapeutics, Department of Medicine, Columbia University, New York, NY 10032, USA
| | - Milan Stojanovic
- Division of Clinical Pharmacology and Experimental Therapeutics, Department of Medicine, Columbia University, New York, NY 10032, USA
| | - Qiao Lin
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA
| |
Collapse
|
18
|
Pak N, Saunders DC, Phaneuf CR, Forest CR. Plug-and-play, infrared, laser-mediated PCR in a microfluidic chip. Biomed Microdevices 2012; 14:427-33. [PMID: 22218821 DOI: 10.1007/s10544-011-9619-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Microfluidic polymerase chain reaction (PCR) systems have set milestones for small volume (100 nL-5 μL), amplification speed (100-400 s), and on-chip integration of upstream and downstream sample handling including purification and electrophoretic separation functionality. In practice, the microfluidic chips in these systems require either insertion of thermocouples or calibration prior to every amplification. These factors can offset the speed advantages of microfluidic PCR and have likely hindered commercialization. We present an infrared, laser-mediated, PCR system that features a single calibration, accurate and repeatable precision alignment, and systematic thermal modeling and management for reproducible, open-loop control of PCR in 1 μL chambers of a polymer microfluidic chip. Total cycle time is less than 12 min: 1 min to fill and seal, 10 min to amplify, and 1 min to recover the sample. We describe the design, basis for its operation, and the precision engineering in the system and microfluidic chip. From a single calibration, we demonstrate PCR amplification of a 500 bp amplicon from λ-phage DNA in multiple consecutive trials on the same instrument as well as multiple identical instruments. This simple, relatively low-cost plug-and-play design is thus accessible to persons who may not be skilled in assembly and engineering.
Collapse
Affiliation(s)
- Nikita Pak
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Room 2103, 315 Ferst Drive, Atlanta, GA, USA.
| | | | | | | |
Collapse
|
19
|
Jung JH, Choi SJ, Park BH, Choi YK, Seo TS. Ultrafast rotary PCR system for multiple influenza viral RNA detection. LAB ON A CHIP 2012; 12:1598-1600. [PMID: 22437437 DOI: 10.1039/c2lc21269b] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We presented a novel platform for an ultrafast PCR system, called the Rotary PCR Genetic Analyzer, which incorporates a thermal block and resistive temperature detector (RTD) for thermal cycling control, a disposable PCR microchip, and a stepper motor. The influenza viral RNAs from H3N2, H5N1, and H1N1 were simultaneously identified with high sensitivity and speed.
Collapse
Affiliation(s)
- Jae Hwan Jung
- Department of Chemical and Biomolecular Engineering (BK21 program) and Institute for the BioCentury, Korea Advanced Institute of Science and Technology (KAIST), Yuseong-gu, Daejeon, South Korea
| | | | | | | | | |
Collapse
|
20
|
Quantitative analysis of molecular absorption into PDMS microfluidic channels. Ann Biomed Eng 2012; 40:1862-73. [PMID: 22484830 DOI: 10.1007/s10439-012-0562-z] [Citation(s) in RCA: 175] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2011] [Accepted: 03/27/2012] [Indexed: 01/07/2023]
Abstract
Microfluidic devices fabricated using poly(dimethylsiloxane) (PDMS) polymer are routinely used for in vitro cell culture for a wide range of cellular assays. These assays typically involve the incubation of cultured cells with a drug molecule or a fluorescent marker while monitoring a cellular response. The accuracy of these assays depends on achieving a consistent and reproducible concentration of solute molecules in solution. However, hydrophobic therapeutic and fluorescent molecules tend to diffuse into the PDMS walls of the microfluidic devices, which reduce their concentration in solution and consequently affect the accuracy and reliability of these assays. In this paper, we quantitatively investigate the relationship between the partition coefficient (log P) of a series of markers routinely used in in vitro cellular assays including [3H]-dexamethasone, [3H]-diazepam, [14C]-mannitol, [3H]-phenytoin, and rhodamine 6G and their absorption into PDMS microfluidic channels. Our results show that the absorption of a given solute into PDMS depends on the hydrophilic/hydrophobic balance defined by its log P value. Specifically, results demonstrate that molecules with log P less than 2.47 exhibit minimal absorption (<10%) into PDMS channels whereas molecules with log P larger than 2.62 exhibit extensive absorption (>90%) into PDMS channels. Further investigations showed that TiO(2) and glass coatings of PDMS channels reduced the absorption of hydrophobic molecules (log P > 2.62) by 2- and 4.5-folds, respectively.
Collapse
|
21
|
Hashimoto M, Torii M, Yoshida K, Noda K, Tsukagoshi K. Instrumentation of a PLC-regulated temperature cycler with a PID control unit and its use for miniaturized PCR systems with reduced volumes of aqueous sample droplets isolated in oil phase in a microwell. ANAL SCI 2012; 27:1191-6. [PMID: 22156245 DOI: 10.2116/analsci.27.1191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
We have developed a temperature cycler for polymerase chain reaction (PCR) in a microwell fabricated on a polymer/glass chip. The entire system consisted of three subsystems, which included (1) a thermal conditioner, (2) a proportional-integral-derivative (PID) control signal conditioner and (3) a data acquisition subsystem. The subsystems were regulated coordinately by a ladder logic program written for the programmable logic control (PLC) so that an actual sample temperature could be timed, changed and maintained according to the programmed temperature cycles. The present temperature control system showed high accuracy, stability and minimum overshoot with reduced heating and cooling transition rates. Applicability of the temperature controller to the miniaturized PCR system with reduced volumes of aqueous sample droplets isolated in an oil phase was confirmed by successful amplifications of a target DNA sequence in the microwell.
Collapse
Affiliation(s)
- Masahiko Hashimoto
- Department of Chemical Engineering and Materials Science, Faculty of Science and Engineering, Doshisha University, Kyotanabe, Kyoto 610–0321, Japan.
| | | | | | | | | |
Collapse
|
22
|
Wang JH, Wang CH, Lee GB. Sample pretreatment and nucleic acid-based detection for fast diagnosis utilizing microfluidic systems. Ann Biomed Eng 2011; 40:1367-83. [PMID: 22146901 PMCID: PMC7088154 DOI: 10.1007/s10439-011-0473-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2011] [Accepted: 11/17/2011] [Indexed: 12/24/2022]
Abstract
Recently, micro-electro-mechanical-systems (MEMS) technology and micromachining techniques have enabled miniaturization of biomedical devices and systems. Not only do these techniques facilitate the development of miniaturized instrumentation for biomedical analysis, but they also open a new era for integration of microdevices for performing accurate and sensitive diagnostic assays. A so-called “micro-total-analysis-system”, which integrates sample pretreatment, transport, reaction, and detection on a small chip in an automatic format, can be realized by combining functional microfluidic components manufactured by specific MEMS technologies. Among the promising applications using microfluidic technologies, nucleic acid-based detection has shown considerable potential recently. For instance, micro-polymerase chain reaction chips for rapid DNA amplification have attracted considerable interest. In addition, microfluidic devices for rapid sample pretreatment prior to nucleic acid-based detection have also achieved significant progress in the recent years. In this review paper, microfluidic systems for sample preparation, nucleic acid amplification and detection for fast diagnosis will be reviewed. These microfluidic devices and systems have several advantages over their large-scale counterparts, including lower sample/reagent consumption, lower power consumption, compact size, faster analysis, and lower per unit cost. The development of these microfluidic devices and systems may provide a revolutionary platform technology for fast sample pretreatment and accurate, sensitive diagnosis.
Collapse
Affiliation(s)
- Jung-Hao Wang
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, 30013 Taiwan, ROC
| | - Chih-Hung Wang
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, 30013 Taiwan, ROC
| | - Gwo-Bin Lee
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, 30013 Taiwan, ROC
| |
Collapse
|
23
|
Njoroge SK, Witek MA, Battle KN, Immethun VE, Hupert ML, Soper SA. Integrated continuous flow polymerase chain reaction and micro-capillary electrophoresis system with bioaffinity preconcentration. Electrophoresis 2011; 32:3221-32. [PMID: 22038569 DOI: 10.1002/elps.201100274] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2011] [Revised: 07/01/2011] [Accepted: 07/04/2011] [Indexed: 12/18/2022]
Abstract
An integrated and modular DNA analysis system is reported that consists of two modules: (i) A continuous flow polymerase chain reaction (CFPCR) module fabricated in a high T(g) (150°C) polycarbonate substrate in which selected gene fragments were amplified using biotin and fluorescently labeled primers accomplished by continuously shuttling small packets of PCR reagents and template through isothermal zones as opposed to heating and cooling large thermal masses typically performed in batch-type thermal reactors. (ii) μCE (micro-capillary electrophoresis) module fabricated in poly(methylmethacrylate) (PMMA), which utilized a bioaffinity selection and purification bed (2.9 μL) to preconcentrate and purify the PCR products generated from the CFPCR module prior to electrophoretic sorting. Biotin-labeled CFPCR products were hydrostatically pumped through the streptavidin-modified bed, where they were extracted onto the surface of micropillars. The affinity bed was also fabricated in PMMA and was populated with an array of microposts (50 μm width; 100 μm height) yielding a total surface area of ∼117 mm(2). This solid-phase extraction (SPE) process demonstrated high selectivity for biotinylated amplicons and utilized the strong streptavidin/biotin interaction (K(d) = 10(-15) M) to generate high recoveries. The SPE selected CFPCR products were thermally denatured and single-stranded DNA released for injection into a 7-cm-long μCE channel for size-based separations and fluorescence detection. The utility of the system was demonstrated using Alu DNA typing for gender and ethnicity determinations as a model. Compared with the traditional cross-T injection procedure typically used for μCE, the affinity pre-concentration and injection procedure generated signal enhancements of 17- to 40-fold, critical for CFPCR thermal cyclers due to Taylor dispersion associated with their operation.
Collapse
Affiliation(s)
- Samuel K Njoroge
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, USA
| | | | | | | | | | | |
Collapse
|
24
|
Mettu S, Chaudhury MK. Motion of liquid drops on surfaces induced by asymmetric vibration: role of contact angle hysteresis. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2011; 27:10327-10333. [PMID: 21728326 DOI: 10.1021/la201597c] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Hysteresis of wetting, like the Coulombic friction at solid/solid interface, impedes the motion of a liquid drop on a surface when subjected to an external field. Here, we present a counterintuitive example, where some amount of hysteresis enables a drop to move on a surface when it is subjected to a periodic but asymmetric vibration. Experiments show that a surface either with a negligible or high hysteresis is not conducive to any drop motion. Some finite hysteresis of contact angle is needed to break the periodic symmetry of the forcing function for the drift to occur. These experimental results are consistent with simulations, in which a drop is approximated as a linear harmonic oscillator. The experiment also sheds light on the effect of the drop size on flow reversal, where drops of different sizes move in opposite directions due to the difference in the phase of the oscillation of their center of mass.
Collapse
Affiliation(s)
- Srinivas Mettu
- Department of Chemical Engineering, Lehigh University, Bethlehem, Pennsylvania 18015, United States
| | | |
Collapse
|
25
|
Park S, Zhang Y, Lin S, Wang TH, Yang S. Advances in microfluidic PCR for point-of-care infectious disease diagnostics. Biotechnol Adv 2011; 29:830-9. [PMID: 21741465 DOI: 10.1016/j.biotechadv.2011.06.017] [Citation(s) in RCA: 218] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2011] [Revised: 05/14/2011] [Accepted: 06/22/2011] [Indexed: 12/20/2022]
Abstract
Global burdens from existing or emerging infectious diseases emphasize the need for point-of-care (POC) diagnostics to enhance timely recognition and intervention. Molecular approaches based on PCR methods have made significant inroads by improving detection time and accuracy but are still largely hampered by resource-intensive processing in centralized laboratories, thereby precluding their routine bedside- or field-use. Microfluidic technologies have enabled miniaturization of PCR processes onto a chip device with potential benefits including speed, cost, portability, throughput, and automation. In this review, we provide an overview of recent advances in microfluidic PCR technologies and discuss practical issues and perspectives related to implementing them into infectious disease diagnostics.
Collapse
Affiliation(s)
- Seungkyung Park
- Department of Emergency Medicine, Johns Hopkins University, Baltimore, MD 21205, USA
| | | | | | | | | |
Collapse
|
26
|
Abstract
We have developed a microfluidic device capable of fully integrated sample preparation and gene analysis from crude biosamples such as whole blood. Our platform takes the advantage of the silica superparamagnetic particle based solid phase extraction to develop an all-in-one scheme that performs cell lysis, DNA binding, washing, elution and the PCR in the same reaction chamber. The device also employs a unique reagent loading scheme, allowing efficient preparation of multiple reactions via a single injection channel. In addition, PCR is performed in a droplet-in-oil manner, eliminating the need for chamber sealing. The combination of these design features greatly reduces the complexity in implementing fully integrated lab-on-a-chip systems for genetic detection, facilitating parallel analysis of multiple samples or genes on a single microchip. The capability of the device is demonstrated by performing DNA isolation from the human whole blood sample and analyzing the Rsf-1 gene using the TaqMan probe based gene specific PCR assays.
Collapse
|
27
|
|
28
|
Maltezos G, Johnston M, Taganov K, Srichantaratsamee C, Gorman J, Baltimore D, Chantratita W, Scherer A. Exploring the limits of ultrafast polymerase chain reaction using liquid for thermal heat exchange: A proof of principle. APPLIED PHYSICS LETTERS 2010; 97:264101. [PMID: 21267083 PMCID: PMC3026011 DOI: 10.1063/1.3530452] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2010] [Accepted: 11/05/2010] [Indexed: 05/11/2023]
Abstract
Thermal ramp rate is a major limiting factor in using real-time polymerase chain reaction (PCR) for routine diagnostics. We explored the limits of speed by using liquid for thermal exchange rather than metal as in traditional devices, and by testing different polymerases. In a clinical setting, our system equaled or surpassed state-of-the-art devices for accuracy in amplifying DNA∕RNA of avian influenza, cytomegalovirus, and human immunodeficiency virus. Using Thermococcus kodakaraensis polymerase and optimizing both electrical and chemical systems, we obtained an accurate, 35 cycle amplification of an 85-base pair fragment of E. coli O157:H7 Shiga toxin gene in as little as 94.1 s, a significant improvement over a typical 1 h PCR amplification.
Collapse
|
29
|
Qiu X, Mauk MG, Chen D, Liu C, Bau HH. A large volume, portable, real-time PCR reactor. LAB ON A CHIP 2010; 10:3170-7. [PMID: 20927453 DOI: 10.1039/c0lc00038h] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
A point-of-care, diagnostic system incorporating a portable thermal cycler and a compact fluorescent detector for real-time, polymerase chain reaction (PCR) on disposable, plastic microfluidic reactors with relatively large reaction volume (ranging from 10 µL to 100 µL) is described. To maintain temperature uniformity and a relatively fast temperature ramping rate, the system utilizes double-sided heater that features a master, thermoelectric element and a thermal waveguide connected to a second thermoelectric element. The waveguide has an aperture for optical coupling between a miniature, fluorescent reader and the PCR reaction chamber. The temperature control is accomplished with a modified, feedforward, variable structural proportional-integral-derivative controller. The temperature of the liquid in the reaction chamber tracks the set-point temperature with an accuracy of ± 0.1 °C. The transition times from one temperature to another are minimized with controllable overshoots (< 2 °C) and undershoots (< 5 °C). The disposable, single-use PCR chip can be quickly inserted into a thermal cycler/reader unit for point-of-care diagnostics applications. The large reaction chamber allows convenient pre-storing of dried, paraffin-encapsulated PCR reagents (polymerase, primers, dNTPs, dyes, and buffers) in the PCR chamber. The reagents are reconstituted "just in time" by heating during the PCR process. The system was tested with viral and bacterial nucleic acid targets.
Collapse
Affiliation(s)
- Xianbo Qiu
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA, USA
| | | | | | | | | |
Collapse
|
30
|
The liposome PCR assay is more sensitive than the Vibrio cholerae enterotoxin and Escherichia coli heat-labile enterotoxin reversed passive latex agglutination test at detecting cholera toxin in feces and water. J Clin Microbiol 2010; 48:4620-2. [PMID: 20962142 DOI: 10.1128/jcm.02019-10] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Practical detection of cholera toxin (CT) by a liposome PCR (LPCR) immunoassay was compared to that of an established V. cholerae enterotoxin and Escherichia coli heat-labile enterotoxin reversed passive latex agglutination (VET-RPLA) assay. LPCR detected CT in the range of 10 pg/ml to 100 ng/ml in simulated feces and environmental water. Detection by VET-RPLA required at least 4 to 19 ng/ml CT.
Collapse
|
31
|
Neuzil P, Novak L, Pipper J, Lee S, Ng LFP, Zhang C. Rapid detection of viral RNA by a pocket-size real-time PCR system. LAB ON A CHIP 2010; 10:2632-2634. [PMID: 20676411 DOI: 10.1039/c004921b] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
We present an economical, battery-powered real-time polymerase chain reaction (RT-PCR) system suitable for field and point-of-care applications; it has a built-in thermal management, a fluorescence-based detection system, and a single chip controller with a graphic touch-screen display.
Collapse
Affiliation(s)
- Pavel Neuzil
- Institute of Bioengineering and Nanotechnology, 31 Biopolis Way, The Nanos, #04-01, Singapore 138669.
| | | | | | | | | | | |
Collapse
|
32
|
Wang F, Wu Z, Lu Y, Wang J, Jiang JH, Yu RQ. A label-free DNAzyme sensor for lead(II) detection by quantitative polymerase chain reaction. Anal Biochem 2010; 405:168-73. [DOI: 10.1016/j.ab.2010.06.026] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2010] [Revised: 06/08/2010] [Accepted: 06/12/2010] [Indexed: 10/19/2022]
|
33
|
Theron J, Eugene Cloete T, de Kwaadsteniet M. Current molecular and emerging nanobiotechnology approaches for the detection of microbial pathogens. Crit Rev Microbiol 2010; 36:318-39. [DOI: 10.3109/1040841x.2010.489892] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
34
|
Lien KY, Lee GB. Miniaturization of molecular biological techniques for gene assay. Analyst 2010; 135:1499-518. [PMID: 20390199 DOI: 10.1039/c000037j] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
The rapid diagnosis of various diseases is a critical advantage of many emerging biomedical tools. Due to advances in preventive medicine, tools for the accurate analysis of genetic mutation and associated hereditary diseases have attracted significant interests in recent years. The entire diagnostic process usually involves two critical steps, namely, sample pre-treatment and genetic analysis. The sample pre-treatment processes such as extraction and purification of the target nucleic acids prior to genetic analysis are essential in molecular diagnostics. The genetic analysis process may require specialized apparatus for nucleic acid amplification, sequencing and detection. Traditionally, pre-treatment of clinical biological samples (e.g. the extraction of deoxyribonucleic acid (DNA) or ribonucleic acid (RNA)) and the analysis of genetic polymorphisms associated with genetic diseases are typically a lengthy and costly process. These labor-intensive and time-consuming processes usually result in a high-cost per diagnosis and hinder their practical applications. Besides, the accuracy of the diagnosis may be affected owing to potential contamination from manual processing. Alternatively, due to significant advances in micro-electro-mechanical-systems (MEMS) and microfluidic technology, there are numerous miniature systems employed in biomedical applications, especially for the rapid diagnosis of genetic diseases. A number of advantages including automation, compactness, disposability, portability, lower cost, shorter diagnosis time, lower sample and reagent consumption, and lower power consumption can be realized by using these microfluidic-based platforms. As a result, microfluidic-based systems are becoming promising platforms for genetic analysis, molecular biology and for the rapid detection of genetic diseases. In this review paper, microfluidic-based platforms capable of identifying genetic sequences and diagnosis of genetic mutations are surveyed and reviewed. Some critical issues with the use of microfluidic-based systems for diagnosis of genetic diseases are also highlighted.
Collapse
Affiliation(s)
- Kang-Yi Lien
- Institute of Nanotechnology and Microsystems Engineering, National Cheng Kung University, Tainan, 701, Taiwan
| | | |
Collapse
|
35
|
Giese H, Lam R, Selden R, Tan E. Fast multiplexed polymerase chain reaction for conventional and microfluidic short tandem repeat analysis. J Forensic Sci 2009; 54:1287-96. [PMID: 19840207 DOI: 10.1111/j.1556-4029.2009.01200.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The time required for short tandem repeat (STR) amplification is determined by the temperature ramp rates of the thermal cycler, the components of the reaction mix, and the properties of the reaction vessel. Multiplex amplifications in microfluidic biochip-based and conventional tube-based thermal cyclers have been demonstrated in 17.3 and 19 min, respectively. Optimized 28-cycle amplification protocols generated alleles with signal strengths above calling thresholds, heterozygous peak height ratios of greater than 0.65, and incomplete nontemplate nucleotide addition and stutter of less than 15%. Full CODIS-compatible profiles were generated using the Profiler Plus ID, COfiler and Identifiler primer sets. PCR performance over a wide range of DNA template levels from 0.006 to 4 ng was characterized by separation and detection on a microfluidic electrophoresis system, Genebench-FX. The fast multiplex PCR approach has the potential to reduce process time and cost for STR analysis and enables development of a fully integrated microfluidic forensic DNA analysis system.
Collapse
|
36
|
Abstract
We show the design, development and assessment of disposable, biocompatible, fully plastic microreactors, which are demonstrated to be highly efficient for genomic analyses, such as amplification of DNA, quantitative analyses in real time, multiplex PCR (both in terms of efficiency and selectivity), as compared to conventional laboratory equipment for PCR. The plastic microreactors can easily be coupled to reusable hardware, enabling heating/cooling processes and, in the case of qPCR applications, the real-time detection of the signal from a suitable fluorescent reporter present in the reaction mixture during the analysis. The low cost production of these polymeric microreactors, along with their applicability to a wide range of biochemical targets, may open new perspectives towards practical applications of biochips for point of care diagnostics.
Collapse
|
37
|
Ramalingam N, Liu HB, Dai CC, Jiang Y, Wang H, Wang Q, M Hui K, Gong HQ. Real-time PCR array chip with capillary-driven sample loading and reactor sealing for point-of-care applications. Biomed Microdevices 2009; 11:1007-20. [PMID: 19421862 DOI: 10.1007/s10544-009-9318-4] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A major challenge for the lab-on-a-chip (LOC) community is to develop point-of-care diagnostic chips that do not use instruments. Such instruments include pumping or liquid handling devices for distribution of patient's nucleic-acid test sample among an array of reactors and microvalves or mechanical parts to seal these reactors. In this paper, we report the development of a primer pair pre-loaded PCR array chip, in which the loading of the PCR mixture into an array of reactors and subsequent sealing of the reactors were realized by a novel capillary-based microfluidics with a manual two-step pipetting operations. The chip is capable of performing simultaneous (parallel) analyses of multiple gene targets and its performance was tested by amplifying twelve different gene targets against cDNA template from human hepatocellular carcinoma using SYBR Green I fluorescent dye. The versatility and reproducibility of the PCR-array chip are demonstrated by real-time PCR amplification of the BNI-1 fragment of SARS cDNA cloned in a plasmid vector. The reactor-to-reactor diffusion of the pre-loaded primer pairs in the chip is investigated to eliminate the possibility of primer cross-contamination. Key technical issues such as PCR mixture loss in gas-permeable PDMS chip layer and bubble generation due to different PDMS-glass bonding methods are investigated.
Collapse
Affiliation(s)
- Naveen Ramalingam
- BioMEMS Laboratory, School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| | | | | | | | | | | | | | | |
Collapse
|
38
|
Zhang Y, Bailey V, Puleo CM, Easwaran H, Griffiths E, Herman JG, Baylin SB, Wang TH. DNA methylation analysis on a droplet-in-oil PCR array. LAB ON A CHIP 2009; 9:1059-64. [PMID: 19350087 PMCID: PMC2829306 DOI: 10.1039/b821780g] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
We performed on-chip DNA methylation analysis using methylation-specific PCR (MSP) within an arrayed micro droplet-in-oil platform that is designed for more practical application of microfluidic droplet technologies in clinical applications. Unique features of this ready-to-use device include arrayed primers that are pre-deposited into open micro-reaction chambers and use of the oil phase as a companion fluid for both sample actuation and compartmentalization. These technical advantages allow for infusion of minute amounts of sample for arrayed MSP analysis, without the added complexities inherent in microfluidic droplet-based studies. Ease of use of this micro device is exemplified by analysis of two tumor suppressor promoters, p15 and TMS1 using an on-chip methylation assay. These results were consistent with standard MSP protocols, yet the simplicity of the droplet-in-oil microfluidic PCR platform provides an easy and efficient tool for DNA methylation analysis in a large-scale arrayed manner.
Collapse
Affiliation(s)
- Yi Zhang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA. Tel: +1-410-516-7086
| | - Vasudev Bailey
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA. Tel: +1-410-516-7086
- Cancer Biology Program, The Sidney Kimmel Comprehensive Cancer Center at Johns Hopkins, Baltimore, MD, 21210, USA
| | - Christopher M. Puleo
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA. Tel: +1-410-516-7086
| | - Hariharan Easwaran
- Cancer Biology Program, The Sidney Kimmel Comprehensive Cancer Center at Johns Hopkins, Baltimore, MD, 21210, USA
| | - Elizabeth Griffiths
- Cancer Biology Program, The Sidney Kimmel Comprehensive Cancer Center at Johns Hopkins, Baltimore, MD, 21210, USA
| | - James G. Herman
- Cancer Biology Program, The Sidney Kimmel Comprehensive Cancer Center at Johns Hopkins, Baltimore, MD, 21210, USA
| | - Stephen B. Baylin
- Cancer Biology Program, The Sidney Kimmel Comprehensive Cancer Center at Johns Hopkins, Baltimore, MD, 21210, USA
| | - Tza-Huei Wang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA. Tel: +1-410-516-7086
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA
| |
Collapse
|
39
|
Herold KE, Sergeev N, Matviyenko A, Rasooly A. Rapid DNA amplification using a battery-powered thin-film resistive thermocycler. Methods Mol Biol 2009; 504:441-58. [PMID: 19159110 PMCID: PMC2844723 DOI: 10.1007/978-1-60327-569-9_24] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/13/2023]
Abstract
A prototype handheld, compact, rapid thermocycler was developed for multiplex analysis of nucleic acids in an inexpensive, portable configuration. Instead of the commonly used Peltier heating/cooling element, electric thin-film resistive heater and a miniature fan enable rapid heating and cooling of glass capillaries leading to a simple, low-cost Thin-Film Resistive Thermocycler (TFRT). Computer-based pulse width modulation control yields heating rates of 6-7 K/s and cooling rates of 5 K/s. The four capillaries are closely coupled to the heater, resulting in low power consumption. The energy required by a nominal PCR cycle (20 s at each temperature) was found to be 57+/-2 J yielding an average power of approximately 1.0 W (not including the computer and the control system). Thus the device can be powered by a standard 9 V alkaline battery (or other 9 V power supply). The prototype TFRT was demonstrated (in a benchtop configuration) for detection of three important food pathogens (E. coli ETEC, Shigella dysenteriae, and Salmonella enterica). PCR amplicons were analyzed by gel electrophoresis. The 35 cycle PCR protocol using a single channel was completed in less then 18 min. Simple and efficient heating/cooling, low cost, rapid amplification, and low power consumption make the device suitable for portable DNA amplification applications including clinical point of care diagnostics and field use.
Collapse
Affiliation(s)
- Keith E Herold
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA
| | | | | | | |
Collapse
|
40
|
Mettu S, Chaudhury MK. Motion of drops on a surface induced by thermal gradient and vibration. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2008; 24:10833-10837. [PMID: 18720961 DOI: 10.1021/la801380s] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
It is well known that a liquid drop with a low contact angle (approximately 45 degrees ) and low wetting hysteresis moves toward the colder region of a temperature gradient substrate as a result of the thermal Marangoni force. A moderately sized water drop, however, usually does not move on such a surface because of the overwhelming effect of hysteresis. The water drop can, however, be forced to move when it is vibrated on a temperature gradient surface with its velocity exhibiting maxima at the respective Rayleigh frequencies. A simple model is presented that captures the dependence of drop velocity on hysteresis, vibration amplitude, and the forcing and resonance frequencies of vibration.
Collapse
Affiliation(s)
- Srinivas Mettu
- Department of Chemical Engineering, Lehigh University, Bethlehem, Pennsylvania 18015, USA
| | | |
Collapse
|
41
|
Sun Y, Nguyen NT, Kwok YC. High-Throughput Polymerase Chain Reaction in Parallel Circular Loops Using Magnetic Actuation. Anal Chem 2008; 80:6127-30. [DOI: 10.1021/ac800787g] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Yi Sun
- National Institute of Education, Nanyang Technological University, 01 Nanyang Walk, Singapore 637616, and School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798
| | - Nam-Trung Nguyen
- National Institute of Education, Nanyang Technological University, 01 Nanyang Walk, Singapore 637616, and School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798
| | - Yien Chian Kwok
- National Institute of Education, Nanyang Technological University, 01 Nanyang Walk, Singapore 637616, and School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798
| |
Collapse
|
42
|
Crews N, Wittwer C, Palais R, Gale B. Product differentiation during continuous-flow thermal gradient PCR. LAB ON A CHIP 2008; 8:919-924. [PMID: 18497912 DOI: 10.1039/b716437h] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
A continuous-flow PCR microfluidic device was developed in which the target DNA product can be detected and identified during its amplification. This in situ characterization potentially eliminates the requirement for further post-PCR analysis. Multiple small targets have been amplified from human genomic DNA, having sizes of 108, 122, and 134 bp. With a DNA dye in the PCR mixture, the amplification and unique melting behavior of each sample is observed from a single fluorescent image. The melting behavior of the amplifying DNA, which depends on its molecular composition, occurs spatially in the thermal gradient PCR device, and can be observed with an optical resolution of 0.1 degrees C pixel(-1). Since many PCR cycles are within the field of view of the CCD camera, melting analysis can be performed at any cycle that contains a significant quantity of amplicon, thereby eliminating the cycle-selection challenges typically associated with continuous-flow PCR microfluidics.
Collapse
Affiliation(s)
- Niel Crews
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT 84112, USA
| | | | | | | |
Collapse
|
43
|
Hagren V, Lode PV, Syrjälä A, Soukka T, Lövgren T, Kojola H, Nurmi J. An automated PCR platform with homogeneous time-resolved fluorescence detection and dry chemistry assay kits. Anal Biochem 2008; 374:411-6. [DOI: 10.1016/j.ab.2007.12.017] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2007] [Revised: 12/11/2007] [Accepted: 12/12/2007] [Indexed: 10/22/2022]
|
44
|
Chen L, West J, Auroux PA, Manz A, Day PJR. Ultrasensitive PCR and real-time detection from human genomic samples using a bidirectional flow microreactor. Anal Chem 2007; 79:9185-90. [PMID: 17979297 DOI: 10.1021/ac701668k] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In this paper we present a reliable bidirectional flow DNA amplification microreactor for processing real-world genomic samples. This system shares the low-power thermal responsiveness of a continuous flow reactor with the low surface area to volume ratio character of stationary reactors for reducing surface inhibitory effects. Silanization with dimethyldichlorosilane in combination with dynamic surface passivation was used to enhance PCR compatibility and enable efficient amplification. For real-time fragment amplification monitoring we have implemented an epimodal fluorescent detection capability. The passivated bidirectional flow system was ultrasensitive, achieving an RNase P gene detection limit of 24 human genome copies with a reaction efficiency of 77%. This starts to rival the performance of a conventional real-time PCR instrument with a reaction efficiency of 93% and revitalizes flow-through PCR as a viable component of lab on a chip DNA analysis formats.
Collapse
Affiliation(s)
- Lin Chen
- Institute for Analytical Sciences, Bunsen-Kirchhoff Strasse 11, D-44139 Dortmund, Germany
| | | | | | | | | |
Collapse
|
45
|
Chen L, Manz A, Day PJR. Total nucleic acid analysis integrated on microfluidic devices. LAB ON A CHIP 2007; 7:1413-23. [PMID: 17960265 DOI: 10.1039/b708362a] [Citation(s) in RCA: 100] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
The design and integration of microfluidic devices for on-chip amplification of nucleic acids from various biological samples has undergone extensive development. The actual benefit to the biological community is far from clear, with a growing, but limited, number of application successes in terms of a full on-chip integrated analysis. Several advances have been made, particularly with the integration of amplification and detection, where amplification is most often the polymerase chain reaction. Full integration including sample preparation remains a major obstacle for achieving a quantitative analysis. We review the recently described devices incorporating in vitro gene amplification and compare devices relative to each other and in terms of fully achieving a miniaturised total analysis system (micro-TAS).
Collapse
Affiliation(s)
- Lin Chen
- Institute for Analytical Sciences, Bunsen-Kirchhoff Str. 11, D-44139 Dortmund, Germany
| | | | | |
Collapse
|
46
|
Horsman KM, Bienvenue JM, Blasier KR, Landers JP. Forensic DNA Analysis on Microfluidic Devices: A Review. J Forensic Sci 2007; 52:784-99. [PMID: 17553097 DOI: 10.1111/j.1556-4029.2007.00468.x] [Citation(s) in RCA: 141] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The advent of microfluidic technology for genetic analysis has begun to impact forensic science. Recent advances in microfluidic separation of short-tandem-repeat (STR) fragments has provided unprecedented potential for improving speed and efficiency of DNA typing. In addition, the analytical processes associated with sample preparation--which include cell sorting, DNA extraction, DNA quantitation, and DNA amplification--can all be integrated with the STR separation in a seamless manner. The current state of these microfluidic methods as well as their advantages and potential shortcomings are detailed. Recent advances in microfluidic device technology, as they pertain to forensic DNA typing, are discussed with a focus on the forensic community.
Collapse
Affiliation(s)
- Katie M Horsman
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
| | | | | | | |
Collapse
|
47
|
Abstract
We have developed a fully integrated multichannel polymerase chain reaction-capillary electrophoresis (PCR-CE) microdevice with nanoliter reactor volumes for highly parallel genetic analyses. Resistance temperature detectors and heaters made out of Ti/Pt are integrated on the microchip using a scalable radial design to provide precise temperature control of the four parallel PCR-CE reactor systems. Heating rates of >15 degrees C s(-1) and cooling rates of >10 degrees C s(-1) allow cycle times of 50 s and 30 complete PCR cycles in <27 min. PDMS membrane valves control and localize PCR reagents in the 380-nL reactors. By directly integrating PCR reactors with the CE separation system, efficient coupling of amplification with separation is achieved. The microdevice demonstrates good amplification uniformity and sensitivity down to 10 initial template copies in the 380-nL reactor (approximately 43 aM) with signal-to-noise ratio greater than 10. Parallel PCR-CE multiplex amplification and genetic analyses of four different samples with (1) both M13mp18 control template and E. coli K12 cells, (2) only M13mp18 template, (3) only E. coli K12 cells, and (4) negative control are completed in less than 30 min in a single run.
Collapse
Affiliation(s)
- Chung N Liu
- Department of Chemical Engineering, UCSF/UC Berkeley Joint Graduate Group in Bioengineering, University of California, Berkeley, California 94720, USA
| | | | | |
Collapse
|
48
|
Dorfman KD, Chabert M, Codarbox JH, Rousseau G, de Cremoux P, Viovy JL. Contamination-free continuous flow microfluidic polymerase chain reaction for quantitative and clinical applications. Anal Chem 2007; 77:3700-4. [PMID: 15924408 DOI: 10.1021/ac050031i] [Citation(s) in RCA: 93] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We present a method for performing polymerase chain reaction (PCR) using isolated droplets flowing in an immiscible fluorinated solvent system. Thanks to an optimized control of interfacial properties, we could achieve in this capillary-based system reproducible amplification factors, without any detectable contamination between neighboring droplets. The system is readily amenable to further miniaturization and automation and serves as the first step toward a clinically viable, high-throughput, quantitative continuous flow PCR apparatus.
Collapse
Affiliation(s)
- Kevin D Dorfman
- Laboratoire Physicochimie-Curie, UMR/CNRS 168, Institut Curie Section de Recherche, 26 Rue d'Ulm, F-75248 Paris Cedex, France
| | | | | | | | | | | |
Collapse
|
49
|
Jia G, Siegrist J, Deng C, Zoval JV, Stewart G, Peytavi R, Huletsky A, Bergeron MG, Madou MJ. A low-cost, disposable card for rapid polymerase chain reaction. Colloids Surf B Biointerfaces 2007; 58:52-60. [PMID: 17499979 DOI: 10.1016/j.colsurfb.2007.03.007] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2007] [Accepted: 03/08/2007] [Indexed: 11/23/2022]
Abstract
A low-cost, disposable card for rapid polymerase chain reaction (PCR) was developed in this work. Commercially available, adhesive-coated aluminum foils and polypropylene films were laminated with structured polycarbonate films to form microreactors in a card format. Ice valves [1] were employed to seal the reaction chambers during thermal cycling and a Peltier-based thermal cycler was configured for rapid thermal cycling and ice valve actuation. Numerical modeling was conducted to optimize the design of the PCR reactor and investigate the thermal gradient in the reaction chamber in the direction of sample thickness. The PCR reactor was experimentally characterized by using thin foil thermocouples and validated by a successful amplification of 10 copy of E. coli tuf gene in 27 min.
Collapse
Affiliation(s)
- Guangyao Jia
- Department of Mechanical & Aerospace Engineering, University of California at Irvine, Irvine, CA 92697, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Hou CSJ, Godin M, Payer K, Chakrabarti R, Manalis SR. Integrated microelectronic device for label-free nucleic acid amplification and detection. LAB ON A CHIP 2007; 7:347-54. [PMID: 17330166 DOI: 10.1039/b617082j] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
We present an integrated microelectronic device for amplification and label-free detection of nucleic acids. Amplification by polymerase chain reaction (PCR) is achieved with on-chip metal resistive heaters, temperature sensors, and microfluidic valves. We demonstrate a rapid thermocycling with rates of up to 50 degrees C s(-1) and a PCR product yield equivalent to that of a bench-top system. Amplicons within the PCR product are detected by their intrinsic charge with a silicon field-effect sensor. Similar to existing optical approaches with intercalators such as SYBR Green, our sensing approach can directly detect standard double-stranded PCR product, while in contrast, our sensor does not require labeling reagents. By combining amplification and detection on the same device, we show that the presence or absence of a particular DNA sequence can be determined by converting the analog surface potential output of the field-effect sensor to a simple digital true/false readout.
Collapse
Affiliation(s)
- Chih-Sheng Johnson Hou
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | | | | | | | | |
Collapse
|