1
|
Orouji A, Ghamsari M, Abbasi-Moayed S, Akbari M, Maaza M, Hormozi-Nezhad MR. Gold nanorods as multidimensional optical nanomaterials: machine learning-enhanced quantitative fingerprinting of proteins for diagnostic applications. NANOSCALE 2025; 17:7957-7969. [PMID: 40065699 DOI: 10.1039/d4nr04797d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/29/2025]
Abstract
The rapid and precise quantification and identification of proteins as key diagnostic biomarkers hold significant promise in allergy testing, disease diagnosis, clinical treatment, and proteomics. This is crucial because alterations in disease-associated genetic information during pathogenesis often result in changes in protein types and levels. Therefore, the design of portable, fast, user-friendly, and affordable sensing platforms rather than a single-sensor-per-analyte strategy for multiplex protein detection is quite consequential. In the present research, a robust multicolorimetric probe based on the inhibited etching of gold nanorods (AuNRs) allowing unambiguous high-performance visual and spectral quantification and identification of proteins in human urine samples was designed. Most recently, we discovered that N-bromosuccinimide (NBS) can quickly etch AuNRs with a distinct color change, allowing convenient and accurate visual recognition of all amino acids. Herein, further explorations revealed that the presence of proteins, as amino acids' polymers, reduces the effective concentration of NBS to different amounts and in turn prevents the etching of AuNRs to various degrees, thereby allowing precise quantification and identification of various proteins ranging from phosphatase (ACP), pepsin (Pep), hemoglobin (Hem), and transferrin (TRF) to immunoglobulin G (IgG), lysozyme (Lys), fibrinogen (Fib), and human serum albumin (HSA). The acquired dataset was statistically analyzed using linear discriminant analysis (LDA), partial least-squares regression (PLSR), and hierarchical cluster analysis (HCA) to accurately classify and identify individual proteins and their combinations at various levels. The multivariate regression models indicated that the colorimetric responses were linearly dependent on protein concentrations with low detection limits of around 1 ppm. Most importantly, the proposed multidimensional colorimetric probe was successfully utilized for protein discrimination in real urine samples. The diverse rainbow responses exhibited by the AuNRs in the proposed probe greatly enhance the accuracy of visual detection, making it a practical tool for straightforward protein monitoring in real samples.
Collapse
Affiliation(s)
- Afsaneh Orouji
- Department of Chemistry, Sharif University of Technology, Tehran, 111559516, Iran.
| | - Mahdi Ghamsari
- Department of Chemistry, Sharif University of Technology, Tehran, 111559516, Iran.
| | - Samira Abbasi-Moayed
- Department of Analytical Chemistry, Faculty of Chemistry, Kharazmi University, Tehran, 15719-14911, Iran
| | - Mahmood Akbari
- UNESCO-UNISA-iTALBS Africa Chair in Nanoscience & Nanotechnology (U2ACN2), College of Graduate Studies, University of South Africa (UNISA), Pretoria, South Africa
| | - Malik Maaza
- UNESCO-UNISA-iTALBS Africa Chair in Nanoscience & Nanotechnology (U2ACN2), College of Graduate Studies, University of South Africa (UNISA), Pretoria, South Africa
| | | |
Collapse
|
2
|
Nath K, Sarkar D, DasGupta S. Paper-based microfluidic device for serum zinc assay by colorimetry. Analyst 2025; 150:1347-1360. [PMID: 40019347 DOI: 10.1039/d5an00023h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/01/2025]
Abstract
Zinc is an essential micronutrient playing several crucial roles in human pathophysiology and its deficiency leads to micronutrient malnutrition. Therefore, a rapid, inexpensive, and accurate protocol for serum zinc concentration measurement becomes essential in community healthcare. This study demonstrates the design, fabrication, and characterization of a low-cost, paper-based microfluidic device (μPAD) to detect serum zinc concentration by colorimetric techniques. The μPAD comprises circular spotting zones doped with diphenylthiocarbazone, commonly known as dithizone, that produces pink-colored chelates upon reacting with zinc and the color intensity monotonically changes with concentration even across the physiological range (i.e., 5-25 μM). The design and the doping protocol were optimized to generate a linear correlation (in water, R2 = 0.94; in artificial plasma, R2 = 0.98) between a suitable optical measure (i.e., the normalized Euclidean shift) evaluated by image analysis of photographs captured by the camera of a standard smartphone and zinc concentration. The calibration curve for artificial plasma was further used to evaluate the zinc concentrations in real blood serum samples, resulting in a high parity with the respective gold standard method. The device is expected to significantly contribute in diagnosis of micronutrient malnutrition with a particular emphasis on community healthcare and to reach resource-limited settings.
Collapse
Affiliation(s)
- Kalpita Nath
- Department of Chemical Engineering, IIT Kharagpur, Kharagpur, 721302, India.
| | - Debasish Sarkar
- Hydrogen and Electrochemistry Department, Idaho National Laboratory, Idaho Falls-83401, USA.
| | - Sunando DasGupta
- Department of Chemical Engineering, IIT Kharagpur, Kharagpur, 721302, India.
| |
Collapse
|
3
|
Zhu J, Hoettges K, Wang Y, Ma H, Song P, Hu Y, Lim EG, Zhang Q. TimePAD─Unveiling Temporal Sequence ELISA Signal by Deep Learning for Rapid Readout and Improved Accuracy in a Microfluidic Paper-Based Analytical Platform. Anal Chem 2025; 97:4515-4523. [PMID: 39960863 DOI: 10.1021/acs.analchem.4c06001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2025]
Abstract
The integration of paper-based microfluidics with deep learning represents a pivotal trend in enhancing diagnostic capabilities. This paper introduces a new approach to improve the performance of a paper-based microfluidic enzyme-linked immunosorbent assay (ELISA) by training the temporal sequence colorimetric data rather than static data conventionally, using deep learning. Traditional deep learning-assisted ELISA analysis methods usually rely on a single snapshot of the reaction at its end, which limits the further improvement of sensitivity and specificity (or accuracy for combined evaluation), as it misses dynamic changes in the reaction over time. In this work, we developed a temporal sequence-enhanced paper analytical device (TimePAD) that captures continuous video data of the ELISA reaction, which contains the dynamic colorimetric changes. With the YOLOv8 deep learning alogrithm and the Rabbit IgG as the model for ELISA assay, we can use the initial 20 min signal instead of waiting for 30 min for full reaction, achieving a 33% reduction in the turnaround time. Moreover, the overall accuracy at 20 min is 94.1%, which is slightly improvement to the 93.5% using a traditional single snapshot method at 30 min. This method not only accelerates result interpretation but also enhances the overall efficiency of diagnostics, making it particularly valuable for time-sensitive point-of-care testing applications. Lastly, to demonstrate its real-world use, we expanded to the disease biomarker cTnI detection and obtained accuracy of 98.1% within only 10 min, compared to 25 min with 97.8% accuracy in traditional methods.
Collapse
Affiliation(s)
- Jia Zhu
- School of Advanced Technology, Xi'an Jiaotong-Liverpool University, Suzhou, Jiangsu 215000, China
- School of Intelligent Manufacturing and Smart Transportation, Suzhou City University, Suzhou, Jiangsu 215000, China
- Department of Electrical and Electronic Engineering, University of Liverpool, Liverpool L69 3GJ, U.K
| | - Kai Hoettges
- Department of Electrical and Electronic Engineering, University of Liverpool, Liverpool L69 3GJ, U.K
| | - Yongjie Wang
- School of Science, Harbin Institute of Technology-Shenzhen 518000 Shenzhen, China
| | - Haibo Ma
- School of Advanced Technology, Xi'an Jiaotong-Liverpool University, Suzhou, Jiangsu 215000, China
- Department of Electrical and Electronic Engineering, University of Liverpool, Liverpool L69 3GJ, U.K
| | - Pengfei Song
- School of Advanced Technology, Xi'an Jiaotong-Liverpool University, Suzhou, Jiangsu 215000, China
- Department of Electrical and Electronic Engineering, University of Liverpool, Liverpool L69 3GJ, U.K
| | - Yong Hu
- School of Mechanical and Aerospace Engineering, Jilin University, Changchun, Jilin 130000, China
| | - Eng Gee Lim
- School of Advanced Technology, Xi'an Jiaotong-Liverpool University, Suzhou, Jiangsu 215000, China
- Department of Electrical and Electronic Engineering, University of Liverpool, Liverpool L69 3GJ, U.K
| | - Quan Zhang
- School of Advanced Technology, Xi'an Jiaotong-Liverpool University, Suzhou, Jiangsu 215000, China
- Department of Electrical and Electronic Engineering, University of Liverpool, Liverpool L69 3GJ, U.K
| |
Collapse
|
4
|
Huang Y, Wu J, Yang W, Qiu Q, Liu Q, Li J, Wen J, Cheng W, Xia X. A rapid, multiplexed and naked-eye readable paper assay for detecting heavy metal pollution in food using a catalytic colorimetric reaction. J Dairy Sci 2025:S0022-0302(24)01446-2. [PMID: 39778792 DOI: 10.3168/jds.2024-25838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2024] [Accepted: 12/10/2024] [Indexed: 01/11/2025]
Abstract
Heavy metal contamination is a serious food safety issue. Herein, we report a rapid, multiplexed and naked-eye readable method for detecting heavy metal pollution in food samples using a cheap colorimetric paper, including milk. We leverage the urease catalysis reaction to amplify the presence of heavy metal ions, Hg2+ and Pb2+, by exploiting their strong inhibitory effect on urease. Integrating with a paper-folding strategy, the visual assay realizes rapid detection of over 10 samples within 5 min. It allowed to detection of Hg2+ as low as 0.1 nM and Pb2+ as low as 2 μM, and the results can be read out either by naked eyes or smartphones. Results can be visually interpreted with the naked eye or a smartphone, making it practical for on-site testing and ensuring the safety of dairy products against metal contamination.
Collapse
Affiliation(s)
- Ying Huang
- Department of Brewing Engineering, Moutai Institute, Renhuai 564507, China
| | - Jianwei Wu
- College of Biomass Science and Engineering, Sichuan University, Chengdu, 610065, China
| | - Wenping Yang
- Department of Brewing Engineering, Moutai Institute, Renhuai 564507, China
| | - Qilin Qiu
- Department of Brewing Engineering, Moutai Institute, Renhuai 564507, China
| | - Qin Liu
- Department of Brewing Engineering, Moutai Institute, Renhuai 564507, China
| | - Jie Li
- Department of Brewing Engineering, Moutai Institute, Renhuai 564507, China
| | - Jiangwei Wen
- Department of Brewing Engineering, Moutai Institute, Renhuai 564507, China
| | - Wenbo Cheng
- Department of Brewing Engineering, Moutai Institute, Renhuai 564507, China
| | - Xuhan Xia
- College of Biomass Science and Engineering, Sichuan University, Chengdu, 610065, China.
| |
Collapse
|
5
|
Wan Y, Zhang M, Liu Z, Wang B, Liu Y, Chen P, Li Y, Du W, Feng X, Liu BF. Rapid parallel blood typing on centrifugal microfluidic platform by microcolumn gel immunoassay. Talanta 2025; 282:126959. [PMID: 39341062 DOI: 10.1016/j.talanta.2024.126959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 09/22/2024] [Accepted: 09/24/2024] [Indexed: 09/30/2024]
Abstract
Microcolumn gel immunoassay (MGIA) has the ability to meet the requirements of clinical diagnosis due to its reliable sensitivity and accuracy. However, traditional MGIA exhibits limitations including inadequate portability, low throughput, and extended analysis time. To address these challenges, we combined MGIA with microfluidic technology, demonstrating a centrifugal microfluidic-based microcolumn gel immunoassay (μMGIA) platform for blood typing of clinical samples. Experimental results indicate that the μMGIA platform can simultaneously detect six blood group antigens in five clinical blood samples within 2 min. Notably, it offers comprehensive detection of ABO blood group antigens and Rh blood group antigens with 100 % accuracy, outperforming the traditional slide method. The integration of microfluidic technology with MGIA circumvents the constraints of traditional methods, providing a new avenue for blood typing and immunoanalysis of clinical samples.
Collapse
Affiliation(s)
- Yaru Wan
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Mingyu Zhang
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Zetai Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Bangfeng Wang
- Institute of Science and Technology for Brain-Inspired Intelligence, Research Institute of Intelligent Complex Systems, Fudan University, Shanghai, 200433, China
| | - Yangcheng Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Peng Chen
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yiwei Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Wei Du
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Xiaojun Feng
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China.
| | - Bi-Feng Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China.
| |
Collapse
|
6
|
Moeinfard T, Ghafar-Zadeh E, Magierowski S. CMOS Point-of-Care Diagnostics Technologies: Recent Advances and Future Prospects. MICROMACHINES 2024; 15:1320. [PMID: 39597132 PMCID: PMC11596111 DOI: 10.3390/mi15111320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2024] [Revised: 10/23/2024] [Accepted: 10/25/2024] [Indexed: 11/29/2024]
Abstract
This review provides a comprehensive overview of point-of-care (PoC) devices across several key diagnostic applications, including blood analysis, infectious disease detection, neural interfaces, and commercialized integrated circuits (ICs). In the blood analysis section, the focus is on biomarkers such as glucose, dopamine, and aptamers, and their respective detection techniques. The infectious disease section explores PoC technologies for detecting pathogens, RNA, and DNA, highlighting innovations in molecular diagnostics. The neural interface section reviews advancements in neural recording and stimulation for therapeutic applications. Finally, a survey of commercialized ICs from companies such as Abbott and Medtronic is presented, showcasing existing PoC devices already in widespread clinical use. This review emphasizes the role of complementary metal-oxide-semiconductor (CMOS) technology in enabling compact, efficient diagnostic systems and offers insights into the current and future landscape of PoC devices.
Collapse
Affiliation(s)
- Tania Moeinfard
- Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Toronto, ON M3J 1P3, Canada; (T.M.); (S.M.)
- Biologically Inspired Sensors and Actuators (BioSA) Laboratory, York University, Toronto, ON M3J 1P3, Canada
- Electronic Machine Intelligence Lab, York University, Toronto, ON M3J 1P3, Canada
| | - Ebrahim Ghafar-Zadeh
- Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Toronto, ON M3J 1P3, Canada; (T.M.); (S.M.)
- Biologically Inspired Sensors and Actuators (BioSA) Laboratory, York University, Toronto, ON M3J 1P3, Canada
| | - Sebastian Magierowski
- Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Toronto, ON M3J 1P3, Canada; (T.M.); (S.M.)
- Electronic Machine Intelligence Lab, York University, Toronto, ON M3J 1P3, Canada
| |
Collapse
|
7
|
Zhou J, Li H, Li X, Liang X, Feng Z, He Q, Zhang M, Chen X, Chen H, Zhang H, Guo W. Automatic characterization of capillary flow profile of liquid samples on μTADs based on capacitance measurement. J Chromatogr A 2024; 1735:465328. [PMID: 39232420 DOI: 10.1016/j.chroma.2024.465328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2024] [Revised: 08/24/2024] [Accepted: 08/29/2024] [Indexed: 09/06/2024]
Abstract
Capillary flow profile of liquid samples in porous media is closely related to the important properties of liquid samples, including the viscosity and the surface energy. Therefore, capillary flow profile can be used as an index to differentiate liquid samples with different properties. Fast and automatic characterization of capillary flow profile of liquid samples is necessary. In this work, we develop a portable and economical capacitance acquisition system (CASY) to easily obtain the capillary flow profile of liquid samples on microfluidic thread-based analytical devices (μTADs) by measuring the capacitance during the capillary flow. At first, we validate the accuracy of this method by comparing with the traditional method by video analysis in obtaining the capillary flow profiles in μTADs of cotton threads or glass fiber threads. Then we use it to differentiate liquid samples with different viscosity (mixture of water and glycerol). In addition, capillary flow profile on μTADs with chemical valves (chitosan or sucrose) can also be obtained on this device. Lastly, we show the potential of this device in measurement of hematocrit (HCT) of whole blood samples. This device can be used to catalog liquid biological samples with different properties in point-of-care diagnostics in the near future.
Collapse
Affiliation(s)
- Jie Zhou
- Department of Electrical Engineering, Shantou University, 243 Daxue Road, Shantou, 515063, Guangdong, China
| | - Haonan Li
- Department of Electrical Engineering, Shantou University, 243 Daxue Road, Shantou, 515063, Guangdong, China
| | - Xionghui Li
- Department of Biomedical Engineering, Shantou University, 243 Daxue Road, Shantou, 515063, Guangdong, China
| | - Xuanying Liang
- Department of Biomedical Engineering, Shantou University, 243 Daxue Road, Shantou, 515063, Guangdong, China
| | - Zitao Feng
- Department of Biomedical Engineering, Shantou University, 243 Daxue Road, Shantou, 515063, Guangdong, China
| | - Qinghao He
- Department of Electrical Engineering, Shantou University, 243 Daxue Road, Shantou, 515063, Guangdong, China
| | - Muyang Zhang
- Department of Electrical Engineering, Shantou University, 243 Daxue Road, Shantou, 515063, Guangdong, China
| | - Xinyi Chen
- Department of Biomedical Engineering, Shantou University, 243 Daxue Road, Shantou, 515063, Guangdong, China
| | - Huilin Chen
- Department of Biomedical Engineering, Shantou University, 243 Daxue Road, Shantou, 515063, Guangdong, China
| | - Huiru Zhang
- Guangdong University Research Findings Commercialization Center, Foshan, 528253, Guangdong, China
| | - Weijin Guo
- Department of Biomedical Engineering, Shantou University, 243 Daxue Road, Shantou, 515063, Guangdong, China.
| |
Collapse
|
8
|
Noce E, Zobayed I, Fontenot RJ, Jumet B, Rasheed RM, Turrubiantes J, Preston DJ. Attaining Tailored Wicking Behavior with Additive Manufacturing. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024. [PMID: 39152911 DOI: 10.1021/acs.langmuir.4c01464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/19/2024]
Abstract
Additive manufacturing (AM) has opened a new pathway to create customized wicking materials. With lower manufacturing costs and a larger design space than many alternatives for wicking, AM is of particular value in fields such as thermal management and microfluidics. Fluid propagation during wicking in porous media, however, has largely remained limited to Washburnian (t ) behavior, and optimizing these materials for wicking in a variety of use cases presents a challenge. In this work, we present a method of tailoring wicking behavior to an arbitrary target function of propagation distance versus time, achieved through the use of AM to create nonuniform porous materials. Layers of parallel lines, each successive layer rotated 90° from the last, form a gridded structure with a spatially varying unit cell size for which analytical models for the capillary pressure and solid fraction and a semianalytical model for permeability were found. These models were validated with capillary rise experiments for spatially uniform porous materials over a range of solid fractions from 0.4 to 0.9. Leveraging these models and representing a nonuniform porous material as a series of Ohmic fluidic resistors, we created an inverse design algorithm that generates a wicking material with spatially varying parameters to achieve a specified target function for fluid propagation as a function of time. These materials can exhibit atypical wicking behavior, including fluid propagation displaying simple linear and piecewise linear relationships with time rather than the conventional Washburn relationship.
Collapse
Affiliation(s)
- Evan Noce
- Department of Mechanical Engineering, Rice University, Houston, Texas 77005, United States
| | - Irfan Zobayed
- Department of Mechanical Engineering, Rice University, Houston, Texas 77005, United States
| | - Richard J Fontenot
- Department of Mechanical Engineering, Rice University, Houston, Texas 77005, United States
| | - Barclay Jumet
- Department of Mechanical Engineering, Rice University, Houston, Texas 77005, United States
| | - Rawand M Rasheed
- Department of Mechanical Engineering, Rice University, Houston, Texas 77005, United States
| | - Jennifer Turrubiantes
- Department of Mechanical Engineering, Rice University, Houston, Texas 77005, United States
| | - Daniel J Preston
- Department of Mechanical Engineering, Rice University, Houston, Texas 77005, United States
| |
Collapse
|
9
|
Usala SJ, Vineyard DD, Kastis M, Trindade AA, Gill HS. Comparison of Day-Specific Serum LH, Estradiol, and Progesterone with Mira TM Monitor Urinary LH, Estrone-3-glucuronide, and Pregnanediol-3-glucuronide Levels in Ovulatory Cycles. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:1207. [PMID: 39202489 PMCID: PMC11356644 DOI: 10.3390/medicina60081207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Revised: 07/14/2024] [Accepted: 07/22/2024] [Indexed: 09/03/2024]
Abstract
Background and Objectives: Fertility tracking apps and devices are now currently available, but urinary hormone levels lack accuracy and sensitivity in timing the start of the 6-day fertile window and the precise 24 h interval of transition from ovulation to the luteal phase. We hypothesized the serum hormones estradiol (E2) and progesterone (P) might be better biomarkers for these major ovulatory cycle events, using appropriate mathematical tools. Materials and Methods: Four women provided daily blood samples for serum E2, P, and LH (luteinizing hormone) levels throughout their entire ovulatory cycles, which were indexed to the first day of dominant follicle (DF) collapse (defined as Day 0) determined by transvaginal sonography; therefore, ovulation occurred in the 24 h interval of Day -1 (last day of maximum diameter DF) to Day 0. For comparison, a MiraTM fertility monitor was used to measure daily morning urinary LH (ULH), estrone-3-glucuronide (E3G), and pregnanediol-3-glucuronide (PDG) levels in three of these cycles. Results: There were more fluctuations in the MiraTM hormone levels compared to the serum levels. Previously described methods, the Fertility Indicator Equation (FIE) and Area Under the Curve (AUC) algorithm, were tested for identifying the start of the fertile window and the ovulation/luteal transition point using the day-specific hormone levels. The FIE with E2 levels predicted the start of the 6-day fertile window on Day -7 (two cycles) and Day -5 (two cycles), whereas no identifying signal was found with E3G. However, both pairs of (E2, P) and (E3G, PDG) levels with the AUC algorithm signaled the Day -1 to Day 0 ovulation/luteal transition interval in all cycles. Conclusions: serum E2 and (E2, P) were better biomarkers for signaling the start of the 6-day fertile window, but both MiraTM and serum hormone levels were successful in timing the [Day -1, Day 0] ovulatory/luteal transition interval. These results can presently be applied to urinary hormone monitors for fertility tracking and have implications for the direction of future fertility tracking technology.
Collapse
Affiliation(s)
- Stephen J. Usala
- Department of Internal Medicine, Texas Tech University Health Sciences Center, Amarillo, TX 79106, USA
| | - David D. Vineyard
- Department of Obstetrics and Gynecology, Texas Tech University Health Sciences Center, Amarillo, TX 79106, USA;
| | - Maria Kastis
- School of Medicine, Texas Tech University Health Sciences Center, Lubbock, TX 79430, USA;
| | - A. Alexandre Trindade
- Department of Mathematics and Statistics, Texas Tech University, 1108 Memorial Circle, Lubbock, TX 79409, USA;
| | - Harvinder Singh Gill
- Harvinder Singh Gill, Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA;
| |
Collapse
|
10
|
Lehnert T, Gijs MAM. Microfluidic systems for infectious disease diagnostics. LAB ON A CHIP 2024; 24:1441-1493. [PMID: 38372324 DOI: 10.1039/d4lc00117f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/20/2024]
Abstract
Microorganisms, encompassing both uni- and multicellular entities, exhibit remarkable diversity as omnipresent life forms in nature. They play a pivotal role by supplying essential components for sustaining biological processes across diverse ecosystems, including higher host organisms. The complex interactions within the human gut microbiota are crucial for metabolic functions, immune responses, and biochemical signalling, particularly through the gut-brain axis. Viruses also play important roles in biological processes, for example by increasing genetic diversity through horizontal gene transfer when replicating inside living cells. On the other hand, infection of the human body by microbiological agents may lead to severe physiological disorders and diseases. Infectious diseases pose a significant burden on global healthcare systems, characterized by substantial variations in the epidemiological landscape. Fast spreading antibiotic resistance or uncontrolled outbreaks of communicable diseases are major challenges at present. Furthermore, delivering field-proven point-of-care diagnostic tools to the most severely affected populations in low-resource settings is particularly important and challenging. New paradigms and technological approaches enabling rapid and informed disease management need to be implemented. In this respect, infectious disease diagnostics taking advantage of microfluidic systems combined with integrated biosensor-based pathogen detection offers a host of innovative and promising solutions. In this review, we aim to outline recent activities and progress in the development of microfluidic diagnostic tools. Our literature research mainly covers the last 5 years. We will follow a classification scheme based on the human body systems primarily involved at the clinical level or on specific pathogen transmission modes. Important diseases, such as tuberculosis and malaria, will be addressed more extensively.
Collapse
Affiliation(s)
- Thomas Lehnert
- Laboratory of Microsystems, École Polytechnique Fédérale de Lausanne, Lausanne, CH-1015, Switzerland.
| | - Martin A M Gijs
- Laboratory of Microsystems, École Polytechnique Fédérale de Lausanne, Lausanne, CH-1015, Switzerland.
| |
Collapse
|
11
|
Ardakani F, Hemmateenejad B. Pronounced effect of lamination on plasma separation from whole blood by microfluidic paper-based analytical devices. Anal Chim Acta 2023; 1279:341767. [PMID: 37827667 DOI: 10.1016/j.aca.2023.341767] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Revised: 08/28/2023] [Accepted: 08/29/2023] [Indexed: 10/14/2023]
Abstract
Many diseases are detected through blood tests. Currently, most blood tests are done on plasma instead of whole blood because of the interference of blood cells on detection results. Here, we developed a laminated microfluidic paper-based analytical device (L-μPAD) for the separation of plasma from whole blood without using plasma separation membrane (PSM). A lateral flow design consisting of a circular sampling zone and rectangular detection zone was patterned on the paper substrate using laser printing technology. The μPAD was then laminated after impregnation with KCl solution. Lamination and electrolyte addition represented synergistic effects on the separation by controlling the pore size of the paper. In addition, by preventing evaporation on one hand and squeezing paper pores on the other hand, lamination caused longer movement of the separated plasma, the longest plasma path reported so far. The separation process was monitored using colorimetric reagent bromocresol green and scanning electron microscopy. The process of separation was completed in less than 90s without significant hemolysis and the separated plasma was far from the interfering effect of red blood cells. We used the device for the determination of serum albumin. However, it represents the potential for point-of-care testing in multi-assay experiments too.
Collapse
Affiliation(s)
| | - Bahram Hemmateenejad
- Chemistry Department, Shiraz University, Shiraz, Iran; Medicinal and Natural Products Chemistry Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
| |
Collapse
|
12
|
Zhang Y, Ke L, Sun T, Liu Y, Wei B, Du M. Rapid Detection of Malaria Based on Hairpin-Mediated Amplification and Lateral Flow Detection. MICROMACHINES 2023; 14:1917. [PMID: 37893354 PMCID: PMC10609466 DOI: 10.3390/mi14101917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 09/23/2023] [Accepted: 09/26/2023] [Indexed: 10/29/2023]
Abstract
Malaria is listed as one of the three most hazardous infectious diseases worldwide. Travelers and migrants passing through exit and entry ports are important sources of malaria pandemics globally. Developing accurate and rapid detection technology for malaria is important. Here, a novel hairpin-mediated amplification (HMA) technique was proposed for the detection of four Plasmodium species, including P. falciparum, P. vivax, P. malariae, and P. ovale. Based on the conserved nucleotide sequence of Plasmodium, specific primers and probes were designed for the HMA process, and the amplicon can be detected using lateral flow detection (LFD); the results can be read visually without specialized equipment. The specificity of HMA-LFD was evaluated using nucleic acids extracted from four different Plasmodium species and two virus species. The sensitivity of HMA-LFD was valued using 10× serial dilutions of plasmid containing the template sequence. Moreover, 78 blood samples were collected to compare HMA-LFD and qPCR. The HMA-LFD results were all positive for four different Plasmodium species and negative for the other two virus species. The sensitivity of HMA-LFD was tested to be near five copies/μL. The analysis of clinical samples indicated that the consistency of HMA-LFD and qPCR was approximately 96.15%. Based on these results, the HMA-LFD assay was demonstrated to be a rapid, sensitive, and specific technique for the detection of Plasmodium and has great advantages for on-site detection in low-resource areas and exit and entry ports.
Collapse
Affiliation(s)
- Yang Zhang
- Comprehensive Technical Service Center of Xuzhou Customs, Xuzhou Customs, Xuzhou 221000, China;
| | - Lihui Ke
- Department of Thoracic Surgery, Beijing Tiantan Hospital, Capital Medical University, Beijing 100070, China;
| | - Tao Sun
- Nanjing Customs, Nanjing 210001, China;
| | - Yang Liu
- Department of Health and Quarantine, Nanjing Customs, Nanjing 210001, China;
| | - Bo Wei
- Department of Thoracic Surgery, Beijing Tiantan Hospital, Capital Medical University, Beijing 100070, China;
| | - Minghua Du
- Department of Emergency, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| |
Collapse
|
13
|
Ijadi Bajestani M, Ahmadzadeh H. Modified polysulfone membrane facilitates rapid separation of plasma from whole blood for an effective anti-SARS-CoV-2-IgM diagnosis. Sci Rep 2023; 13:13712. [PMID: 37608047 PMCID: PMC10444766 DOI: 10.1038/s41598-023-40871-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Accepted: 08/17/2023] [Indexed: 08/24/2023] Open
Abstract
During the outbreak of coronavirus, RT-PCR was the premier gold standard method for severe acute respiratory syndrome coronavirus 2 (SARSCoV-2) diagnosis. However, the sophisticated procedure of RT-PCR persuades researchers to develop sustainable point-of-need immunoassay methods for tracing unwitting carriers of SARSCoV-2. Herein, by fabricating a modified polysulfone (MPSF) membrane, we developed an integrated radial flow immunoassay (IRFIA) platform as a point-of-care system, capable of multiplying the immunoassays at a short run time. The target molecule is the SARSCoV-2 IgM in separated plasma. Although the lateral flow immunoassay kits for the rapid identification of Covid-19 have already been commercially developed but, the proposed method is superior to the conventional lateral flow immunoassay. In the newly designed membrane system, we have combined the five membranes of prevalent lateral flow immunoassay (LFIA) strips in one polymeric membrane. The MPSF membrane is capable of separating plasma from whole blood sample, which will reduce the interference of red colour of hemoglobin with generated signal and enhance the immunoassay precision. The efficiency of plasma separation, reached the mean value of 97.34 v/v% in 5 s. Furthermore, the gel electrophoresis results of the separated plasma contrasted with centrifuged plasma sample, demonstrated more efficient separation by the membrane. Using the MPSF membrane, signal generation time reduced from about 20 min in conventional rapid test strip for Covid-19 to about 7 min in IRFIA platform. The sensitivity and specificity of the membrane platform were determined to be 89% and 90%, respectively and a Kappa coefficient of 0.79 showed reliable agreement between the RT-PCR and the membrane system.
Collapse
Affiliation(s)
- Maryam Ijadi Bajestani
- Faculty of Science, Department of Chemistry, Ferdowsi University of Mashhad, Mashhad, 9177948974, Iran
| | - Hossein Ahmadzadeh
- Faculty of Science, Department of Chemistry, Ferdowsi University of Mashhad, Mashhad, 9177948974, Iran.
| |
Collapse
|
14
|
Bazyar H. On the Application of Microfluidic-Based Technologies in Forensics: A Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:5856. [PMID: 37447704 PMCID: PMC10346202 DOI: 10.3390/s23135856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 06/21/2023] [Accepted: 06/22/2023] [Indexed: 07/15/2023]
Abstract
Microfluidic technology is a powerful tool to enable the rapid, accurate, and on-site analysis of forensically relevant evidence on a crime scene. This review paper provides a summary on the application of this technology in various forensic investigation fields spanning from forensic serology and human identification to discriminating and analyzing diverse classes of drugs and explosives. Each aspect is further explained by providing a short summary on general forensic workflow and investigations for body fluid identification as well as through the analysis of drugs and explosives. Microfluidic technology, including fabrication methodologies, materials, and working modules, are touched upon. Finally, the current shortcomings on the implementation of the microfluidic technology in the forensic field are discussed along with the future perspectives.
Collapse
Affiliation(s)
- Hanieh Bazyar
- Engineering Thermodynamics, Process & Energy Department, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Leeghwaterstraat 39, 2628CB Delft, The Netherlands
| |
Collapse
|
15
|
Point-of-care diagnostics for sepsis using clinical biomarkers and microfluidic technology. Biosens Bioelectron 2023; 227:115181. [PMID: 36867959 DOI: 10.1016/j.bios.2023.115181] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 02/13/2023] [Accepted: 02/23/2023] [Indexed: 03/05/2023]
Abstract
Sepsis is a life-threatening immune response which is caused by a wide variety of sources and is a leading cause of mortality globally. Rapid diagnosis and appropriate antibiotic treatment are critical for successful patient outcomes; however, current molecular diagnostic techniques are time-consuming, costly and require trained personnel. Additionally, there is a lack of rapid point-of-care (POC) devices available for sepsis detection despite the urgent requirements in emergency departments and low-resource areas. Recent advances have been made toward developing a POC test for early sepsis detection that will be more rapid and accurate compared to conventional techniques. Within this context, this review discusses the use of current and novel biomarkers for early sepsis diagnosis using microfluidics devices for POC testing.
Collapse
|
16
|
Suardi N, Germanam SJ, Rahim NAYM. Acoustic evaluation of photobiomodulation effect on in vitro human blood samples. Lasers Med Sci 2023; 38:99. [PMID: 37059895 DOI: 10.1007/s10103-023-03766-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 04/04/2023] [Indexed: 04/16/2023]
Abstract
Although positive photobiomodulation response on wound healing, tissue repair, and therapeutic treatment has been widely reported, additional works are still needed to understand its effects on human blood. This research carried out acoustic measurements using A-scan (GAMPT) ultrasonic techniques to elucidate the photobiomodulation effects on in vitro human blood samples as therapeutic treatment measures. The human blood samples were irradiated using a 532-nm laser with different output laser powers (60 and 80 mW) at various exposure times. The ultrasonic velocity measured in the human blood samples after laser irradiation showed significant changes, most of which were within the acceptance limit for soft tissues (1570 [Formula: see text] 30 m/s). Abnormal cells (echinocyte and crenation) were observed due to excessive exposure during laser treatment.
Collapse
Affiliation(s)
- Nursakinah Suardi
- School of Physics, Universiti Sains Malaysia, 11800, Penang, Malaysia.
| | | | | |
Collapse
|
17
|
Rey Gomez LM, Hirani R, Care A, Inglis DW, Wang Y. Emerging Microfluidic Devices for Sample Preparation of Undiluted Whole Blood to Enable the Detection of Biomarkers. ACS Sens 2023; 8:1404-1421. [PMID: 37011238 DOI: 10.1021/acssensors.2c02696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023]
Abstract
Blood testing allows for diagnosis and monitoring of numerous conditions and illnesses; it forms an essential pillar of the health industry that continues to grow in market value. Due to the complex physical and biological nature of blood, samples must be carefully collected and prepared to obtain accurate and reliable analysis results with minimal background signal. Examples of common sample preparation steps include dilutions, plasma separation, cell lysis, and nucleic acid extraction and isolation, which are time-consuming and can introduce risks of sample cross-contamination or pathogen exposure to laboratory staff. Moreover, the reagents and equipment needed can be costly and difficult to obtain in point-of-care or resource-limited settings. Microfluidic devices can perform sample preparation steps in a simpler, faster, and more affordable manner. Devices can be carried to areas that are difficult to access or that do not have the resources necessary. Although many microfluidic devices have been developed in the last 5 years, few were designed for the use of undiluted whole blood as a starting point, which eliminates the need for blood dilution and minimizes blood sample preparation. This review will first provide a short summary on blood properties and blood samples typically used for analysis, before delving into innovative advances in microfluidic devices over the last 5 years that address the hurdles of blood sample preparation. The devices will be categorized by application and the type of blood sample used. The final section focuses on devices for the detection of intracellular nucleic acids, because these require more extensive sample preparation steps, and the challenges involved in adapting this technology and potential improvements are discussed.
Collapse
Affiliation(s)
| | - Rena Hirani
- Australian Red Cross Lifeblood, Sydney, New South Wales 2015, Australia
| | - Andrew Care
- School of Life Sciences, University of Technology Sydney, Ultimo, New South Wales 2007, Australia
| | - David W Inglis
- School of Engineering, Faculty of Science and Engineering and △School of Natural Sciences, Faculty of Science and Engineering, Macquarie University, Sydney, New South Wales 2109, Australia
| | | |
Collapse
|
18
|
Hasan MR, Sharma P, Suleman S, Mukherjee S, Celik EG, Timur S, Pilloton R, Narang J. Papertronics: Marriage between Paper and Electronics Becoming a Real Scenario in Resource-Limited Settings. ACS APPLIED BIO MATERIALS 2023; 6:1368-1379. [PMID: 36926800 DOI: 10.1021/acsabm.2c01070] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2023]
Abstract
Integrating electronic applications with paper, placed next to or below printed images or graphics, can further expand the possible uses of paper substrates. Consuming paper as a substrate in the field of electronics can lead to significant innovations toward papertronics applications as paper comprises various advantages like being disposable, inexpensive, biodegradable, easy to handle, simple to use, and easily available. All of these advantages will definitely spur the advancement of the electronics field, but unfortunately, putting electronics on paper is not an easy task because, compared to plastics, the paper surface is not just rough but also porous. For example, in the case of lateral flow assay testing the sensor response is delayed if the pore size of the paper is enormous. This might be a disadvantage for most electrical devices printed directly on paper. Still, some methods make it compatible when fit with a rough, absorbent surface of the paper. Building electronic devices on a standard paper substrate have sparked much interest because of its lightweight, environmental friendliness, minimal cost, and simple fabrication. A slew of improvements have been achieved in recent years to make paper electronics perform better in various applications, including transistors, batteries, and displays. In addition, flexible electronics have gained much interest in human-machine interaction and wireless sensing. This review briefly examines the origins and fabrication of paper electronics and then moves on to applications and exciting possible paths for paper-based electronics.
Collapse
Affiliation(s)
- Mohd Rahil Hasan
- Department of Biotechnology, Jamia Hamdard University, New Delhi 110062, India
| | - Pradakshina Sharma
- Department of Biotechnology, Jamia Hamdard University, New Delhi 110062, India
| | - Shariq Suleman
- Department of Biotechnology, Jamia Hamdard University, New Delhi 110062, India
| | - Shouvik Mukherjee
- Department of Biotechnology, Jamia Hamdard University, New Delhi 110062, India
| | - Emine Guler Celik
- Department of Bioengineering, Faculty of Engineering, Ege University, 35100 Bornova, Izmir, Turkey
| | - Suna Timur
- Department of Biochemistry, Faculty of Science, Ege University, 35100 Bornova, Izmir, Turkey.,Central Research Test and Analysis Laboratory Application and Research Center, Ege University, 35100 Bornova, Izmir, Turkey
| | - Roberto Pilloton
- CNR-IC, Area della Ricerca di RM1, Via Salaria km 29.3, Monterotondo, Rome I-00015, Italy
| | - Jagriti Narang
- Department of Biotechnology, Jamia Hamdard University, New Delhi 110062, India
| |
Collapse
|
19
|
Microfluidic-based blood immunoassays. J Pharm Biomed Anal 2023; 228:115313. [PMID: 36868029 DOI: 10.1016/j.jpba.2023.115313] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 02/09/2023] [Accepted: 02/22/2023] [Indexed: 02/26/2023]
Abstract
Microfluidics enables the integration of whole protocols performed in a laboratory, including sample loading, reaction, extraction, and measurement steps on a single system, which offers significant advantages thanks to small-scale operation combined with precise fluid control. These include providing efficient transportation mechanisms and immobilization, reduced sample and reagent volumes, fast analysis and response times, lower power requirements, lower cost and disposability, improved portability and sensitivity, and greater integration and automation capability. Immunoassay is a specific bioanalytical method based on the interaction of antigens and antibodies, which is utilized to detect bacteria, viruses, proteins, and small molecules in several areas such as biopharmaceutical analysis, environmental analysis, food safety, and clinical diagnostics. Because of the advantages of both techniques, the combination of immunoassays and microfluidic technology is considered one of the most potential biosensor systems for blood samples. This review presents the current progress and important developments in microfluidic-based blood immunoassays. After providing several basic information about blood analysis, immunoassays, and microfluidics, the review points out in-depth information about microfluidic platforms, detection techniques, and commercial microfluidic blood immunoassay platforms. In conclusion, some thoughts and future perspectives are provided.
Collapse
|
20
|
Palekar S, Kalambe J, Patrikar RM. IoT enabled microfluidics-based biochemistry analyzer based on colorimetric detection techniques. CHEMICAL PAPERS 2023. [DOI: 10.1007/s11696-023-02678-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
21
|
Wang X, Zheng X, Song Z, Lin D, Li Q, Qi J, Xiang J, Chen L, Li B. Electric yo-yo centrifugation combining with paper-based microfluidic immunoassay chip for inflammatory biomarkers detection in whole blood. Talanta 2023; 253:123883. [PMID: 36137494 DOI: 10.1016/j.talanta.2022.123883] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 06/25/2022] [Accepted: 08/23/2022] [Indexed: 12/13/2022]
Abstract
At present, most countries or regions use commercial centrifuges for centrifugation, but this is out of reaching for limited-resource areas. To overcome this problem, a portable electric yo-yo as centrifuge was firstly proposed to obtain serum, and this device can be combined with paper-based analytical devices for enzyme-linked immunosorbent assay (ELISA) analysis from human whole blood. In this study, inflammatory biomarkers C-reactive protein (CRP) and serum amyloid A (SAA) were used as target biomarker to verify the performance of the proposed method. The results shows good performance and their detection limits were determined to be 580 pg/mL for CRP and 800 pg/mL for SAA, respectively. We believe this method provides a new platform of low cost and fast detection for inflammatory biomarkers in the limited-resource settings.
Collapse
Affiliation(s)
- Xiaolei Wang
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Institute of Molecular and Nano Science, Shandong Normal University, Jinan, 250014, PR China
| | - Xiaoli Zheng
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Institute of Molecular and Nano Science, Shandong Normal University, Jinan, 250014, PR China
| | - Zhihua Song
- School of Pharmacy, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Key Laboratory of Molecular Pharmacology and Drug Evaluation, Ministry of Education, Yantai University, Yantai, 264005, PR China
| | - Dong Lin
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, PR China
| | - Qingling Li
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Institute of Molecular and Nano Science, Shandong Normal University, Jinan, 250014, PR China
| | - Ji Qi
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, PR China
| | - Jiawen Xiang
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, PR China
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, PR China.
| | - Bowei Li
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, PR China.
| |
Collapse
|
22
|
Udhani R, Kothari C, Sarvaiya J. A Comprehensive Study: Traditional and Cutting-Edge Analytical Techniques for the Biomarker Based Detection of the Micronutrients & POC Sensing Directions for Next-Generation Diagnostic. Crit Rev Anal Chem 2023; 54:2378-2397. [PMID: 36720848 DOI: 10.1080/10408347.2023.2169823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Micronutrient deficiency is wide spread and highly affects morbidity, mortality, and well-being of human beings. Micronutrient deficiency gradually manifests into diseases, which effects pathophysiology directly or indirectly. There is an imprecision in the diagnosis of micronutrient deficiency because of two causes; the selection of the standard biomarker and the diagnostic technique used. In appropriate diagnosis could increase the severity of the disorder. Instead of a single a combination of biomarkers can give more stringent results for micronutrient testing. Several traditional analytical techniques are used for diagnosis but HPLC, ELISA & LCMS/MS are most sensitive and reliable methods used by CLSIA-certified labs. However, these techniques require well-equipped, centralized laboratory facilities. The diagnostic era moves toward the Point of Care Testing (POCT), a boon in emerging diagnostics, breaking all paradigms of traditional analytical techniques. POCT led us toward the development of biosensors, which encompasses many techniques like paper-based sensors, microfluidic chip, wearable devices, and smartphone-assisted diagnostics, which become more popular diagnostic tools. This outlook summarizes the micronutrients like vitamins A, B5, B6, B7, B9, B12 C, D, and E and Minerals like iron, calcium, zinc, magnesium, and sodium; along with its biomarkers, analytical techniques, and point of care innovation in micronutrients.
Collapse
Affiliation(s)
- Raveena Udhani
- Department of Pharmaceutical Analysis, Institute of Pharmacy, Nirma University, Ahmedabad, Gujarat, India
| | - Charmy Kothari
- Department of Pharmaceutical Analysis, Institute of Pharmacy, Nirma University, Ahmedabad, Gujarat, India
| | - Jayrajsinh Sarvaiya
- School of Engineering and Technology, National Forensic Science University, Gandhinagar, Gujarat, India
| |
Collapse
|
23
|
Grigorev GV, Lebedev AV, Wang X, Qian X, Maksimov GV, Lin L. Advances in Microfluidics for Single Red Blood Cell Analysis. BIOSENSORS 2023; 13:117. [PMID: 36671952 PMCID: PMC9856164 DOI: 10.3390/bios13010117] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/04/2022] [Accepted: 12/23/2022] [Indexed: 05/24/2023]
Abstract
The utilizations of microfluidic chips for single RBC (red blood cell) studies have attracted great interests in recent years to filter, trap, analyze, and release single erythrocytes for various applications. Researchers in this field have highlighted the vast potential in developing micro devices for industrial and academia usages, including lab-on-a-chip and organ-on-a-chip systems. This article critically reviews the current state-of-the-art and recent advances of microfluidics for single RBC analyses, including integrated sensors and microfluidic platforms for microscopic/tomographic/spectroscopic single RBC analyses, trapping arrays (including bifurcating channels), dielectrophoretic and agglutination/aggregation studies, as well as clinical implications covering cancer, sepsis, prenatal, and Sickle Cell diseases. Microfluidics based RBC microarrays, sorting/counting and trapping techniques (including acoustic, dielectrophoretic, hydrodynamic, magnetic, and optical techniques) are also reviewed. Lastly, organs on chips, multi-organ chips, and drug discovery involving single RBC are described. The limitations and drawbacks of each technology are addressed and future prospects are discussed.
Collapse
Affiliation(s)
- Georgii V. Grigorev
- Data Science and Information Technology Research Center, Tsinghua Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518055, China
- Mechanical Engineering Department, University of California in Berkeley, Berkeley, CA 94720, USA
- School of Information Technology, Cherepovets State University, 162600 Cherepovets, Russia
| | - Alexander V. Lebedev
- Machine Building Department, Bauman Moscow State University, 105005 Moscow, Russia
| | - Xiaohao Wang
- Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Xiang Qian
- Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - George V. Maksimov
- Faculty of Biology, Lomonosov Moscow State University, 119991 Moscow, Russia
- Physical metallurgy Department, Federal State Autonomous Educational Institution of Higher Education National Research Technological University “MISiS”, 119049 Moscow, Russia
| | - Liwei Lin
- Mechanical Engineering Department, University of California in Berkeley, Berkeley, CA 94720, USA
| |
Collapse
|
24
|
Ding S, Duan S, Chen Y, Xie J, Tian J, Li Y, Wang H. Centrifugal microfluidic platform with digital image analysis for parallel red cell antigen typing. Talanta 2023; 252:123856. [DOI: 10.1016/j.talanta.2022.123856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 08/11/2022] [Accepted: 08/16/2022] [Indexed: 11/26/2022]
|
25
|
Parween S, Asthana A, Nahar P. Fundamentals of Image-Based Assay (IBA) System for Affordable Point of Care Diagnostics. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
26
|
Iakovlev AP, Erofeev AS, Gorelkin PV. Novel Pumping Methods for Microfluidic Devices: A Comprehensive Review. BIOSENSORS 2022; 12:956. [PMID: 36354465 PMCID: PMC9688261 DOI: 10.3390/bios12110956] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 10/26/2022] [Accepted: 10/28/2022] [Indexed: 06/02/2023]
Abstract
This review is an account of methods that use various strategies to control microfluidic flow control with high accuracy. The reviewed systems are divided into two large groups based on the way they create flow: passive systems (non-mechanical systems) and active (mechanical) systems. Each group is presented by a number of device fabrications. We try to explain the main principles of operation, and we list advantages and disadvantages of the presented systems. Mechanical systems are considered in more detail, as they are currently an area of increased interest due to their unique precision flow control and "multitasking". These systems are often applied as mini-laboratories, working autonomously without any additional operations, provided by humans, which is very important under complicated conditions. We also reviewed the integration of autonomous microfluidic systems with a smartphone or single-board computer when all data are retrieved and processed without using a personal computer. In addition, we discuss future trends and possible solutions for further development of this area of technology.
Collapse
Affiliation(s)
| | | | - Petr V. Gorelkin
- Research Laboratory of Biophysics, National University of Science and Technology «MISiS», 119049 Moscow, Russia
| |
Collapse
|
27
|
Saidykhan J, Pointon L, Cinti S, May JE, Killard AJ. Development of a paper-based lateral flow prothrombin assay. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:3718-3726. [PMID: 36048161 DOI: 10.1039/d2ay00965j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Disorders of haemostasis result in both excessive bleeding and clotting and are a major global cause of morbidity and mortality, particularly in the developing world. A small number of simple tests can be used to screen and monitor for such dysfunctions, one of which is the prothrombin time (PT) test and associated International Normalisation Ratio (INR). PT/INR is routine in hospital laboratories in developed countries, and can also be performed using point-of-care instruments. However, neither of these approaches is appropriate in low-resource settings. Significant interest has grown in paper-based devices to form the basis of simple and low-cost assays that may have the potential for application in such environments. This study describes the development of a simple, low-cost, paper-based lateral flow prothrombin assay. The assay employed wax printing on chromatography paper to define test channels, with deposition of thromboplastin reagent and calcium chloride onto the resulting strips. These were placed in a test housing and measurement of the flow rates of deposited plasma samples were performed in triplicate. The flow dynamics of the assay was optimised according to the type of paper substrate used, the nature and quantity of the thromboplastin reagent, the amount of calcium chloride required, and the volume of sample employed. An optimised assay configuration demonstrated a dynamic range of 6 mm between normal and factor-deficient plasmas. The assay showed good correlation with laboratory-based PT assay (Yumizen G200) in artificial plasmas in the 9.8 to 36 s range (r2 = 0.8112). The assay also demonstrated good dynamic range and correlation in patient plasma samples in comparison with hospital PT, with a range of 9.8 to 45 s (r2 = 0.7209).
Collapse
Affiliation(s)
- Jerro Saidykhan
- Department of Applied Sciences, Centre for Research in Biosciences (CRIB), University of the West of England, Coldharbour Lane, Bristol, BS16 1QY, UK.
| | - Louise Pointon
- North Bristol NHS Trust, Southmead Hospital, Bristol, BS10 5NB, UK
| | - Stefano Cinti
- Department of Pharmacy, University of Naples "Federico II", Napoli 80131, Italy
| | - Jennifer E May
- Department of Applied Sciences, Centre for Research in Biosciences (CRIB), University of the West of England, Coldharbour Lane, Bristol, BS16 1QY, UK.
| | - Anthony J Killard
- Department of Applied Sciences, Centre for Research in Biosciences (CRIB), University of the West of England, Coldharbour Lane, Bristol, BS16 1QY, UK.
| |
Collapse
|
28
|
Seder I, Ham KM, Jun BH, Kim SJ. Mechanical Timer-Actuated Fluidic Dispensing System: Applications to an Automated Multistep Lateral Flow Immunoassay with High Sensitivity. Anal Chem 2022; 94:12884-12889. [PMID: 36069050 DOI: 10.1021/acs.analchem.2c02945] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In this study, we present a fluidic dispensing system that can automate the sequential fluidic delivery of multiple reagents for lateral flow assays. Highly sensitive assays typically require multiple solution-based sequences, including washing steps and signal amplification. However, implementation of these types of sequences on an automated and highly sensitive point-of-care testing (POCT) platform remains challenging. Our platform consists of two disposable cartridges with reagent chambers and a test strip and an instrument that has a mechanical timer to actuate the cam-follower-gear components. The timer rotation sequentially shifts the position of the chambers and loads the reagents to the test paper strip. The dispensing intervals are controlled at a variation of <1% within a total actuation time of 60 min. Unlike other POCT devices, the timing of fluid delivery in our timer-actuated platform is not dependent on the selection of substrates and reagents, and the unique approach to fluidic delivery results in no reagent overlap or carryover, minimal reagent loss, and highly accurate fluidic timing control for highly sensitive solution-based assays. As a model application, the proposed platform applies a gold enhancement solution to amplify the detection signal and detect prostate-specific antigen with a limit of detection of 86 pg/mL within 27 min. This platform provides an opportunity for solution-based POCT applications with high sensitivity, thereby satisfying the requirement for user-friendly operations in resource-limited settings.
Collapse
Affiliation(s)
- Islam Seder
- Department of Mechanical Engineering, Konkuk University, Seoul 05029, Republic of Korea
| | - Kyeong-Min Ham
- Department of Bioscience and Biotechnology, Konkuk University, Seoul 05029, Republic of Korea
| | - Bong-Hyun Jun
- Department of Bioscience and Biotechnology, Konkuk University, Seoul 05029, Republic of Korea
| | - Sung-Jin Kim
- Department of Mechanical Engineering, Konkuk University, Seoul 05029, Republic of Korea
| |
Collapse
|
29
|
Ding J, Shi J, Sun X, Lu X, Sun X, Wang J, Ye Y, Xu S, Luo X. pH Programmed Optical Sensor Arrays for Cancer Plasma Straightforward Discrimination Based on Protein-Responsive Patterns. Anal Chem 2022; 94:12546-12551. [PMID: 36040197 DOI: 10.1021/acs.analchem.2c03245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Optical cross-reactive sensor arrays inspired by the mammalian olfactory system that can realize straightforward discrimination of plasma from cancer patients hold great potential for point-of-care diseases diagnostics. Herein, a pH programmed fluorescence sensor array based on protein-responsive patterns was designed for straightforward discrimination of different types of cancer plasma. It is worth noting that plasma discrimination can be realized only by programming one nanomaterial using different pH values, which greatly simplifies the programmable design of the sensor array, making it an important highlight of this work. In addition, the mechanism of the pH programmed fluorescence sensor array for protein responsiveness was systematically investigated through molecular docking simulation, fluorescence resonance energy transfer (FRET), and fluorescence lifetime experiments. Most importantly, not only can the differences between plasma from healthy people and and from patients with different cancer species including gastric cancer, liver cancer, breast cancer, and cervical cancer be discriminated by this pH programmed fluorescence sensor array, but also the blind test of unknown plasma samples can be well identified with 100% accuracy, indicating its promising prospect in clinical application.
Collapse
Affiliation(s)
- Jiaxiang Ding
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, P. R. China.,College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao 266042, P. R. China
| | - Jiaheng Shi
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, P. R. China
| | - Xiaomei Sun
- The Affiliated Hospital of Qingdao University, Qingdao 266003, P. R. China
| | - Xin Lu
- Tianjin Institute for Drug Control, Tianjin 300070, P. R. China
| | - Xicheng Sun
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, P. R. China
| | - Junhao Wang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, P. R. China
| | - Yuhang Ye
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, P. R. China
| | - Shenghao Xu
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, P. R. China
| | - Xiliang Luo
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, P. R. China
| |
Collapse
|
30
|
Xu S, Xu Z, Liu Z. Paper-Based Molecular-Imprinting Technology and Its Application. BIOSENSORS 2022; 12:595. [PMID: 36004991 PMCID: PMC9405720 DOI: 10.3390/bios12080595] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 07/28/2022] [Accepted: 08/02/2022] [Indexed: 11/24/2022]
Abstract
Paper-based analytical devices (PADs) are highly effective tools due to their low cost, portability, low reagent accumulation, and ease of use. Molecularly imprinted polymers (MIP) are also extensively used as biomimetic receptors and specific adsorption materials for capturing target analytes in various complex matrices due to their excellent recognition ability and structural stability. The integration of MIP and PADs (MIP-PADs) realizes the rapid, convenient, and low-cost application of molecular-imprinting analysis technology. This review introduces the characteristics of MIP-PAD technology and discusses its application in the fields of on-site environmental analysis, food-safety monitoring, point-of-care detection, biomarker detection, and exposure assessment. The problems and future development of MIP-PAD technology in practical application are also prospected.
Collapse
Affiliation(s)
| | - Zhigang Xu
- Faculty of Science, Kunming University of Science and Technology, Kunming 650500, China;
| | - Zhimin Liu
- Faculty of Science, Kunming University of Science and Technology, Kunming 650500, China;
| |
Collapse
|
31
|
Xiao X, Yuan C, Li T, Fock J, Svedlindh P, Tian B. Optomagnetic biosensors: Volumetric sensing based on magnetic actuation-induced optical modulations. Biosens Bioelectron 2022; 215:114560. [PMID: 35841765 DOI: 10.1016/j.bios.2022.114560] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 04/25/2022] [Accepted: 07/07/2022] [Indexed: 12/19/2022]
Abstract
In comparison to alternative nanomaterials, magnetic micron/nano-sized particles show unique advantages, e.g., easy manipulation, stable signal, and high contrast. By applying magnetic actuation, magnetic particles exert forces on target objects for highly selective operation even in non-purified samples. We herein describe a subgroup of magnetic biosensors, namely optomagnetic biosensors, which employ alternating magnetic fields to generate periodic movements of magnetic labels. The optical modulation induced by the dynamics of magnetic labels is then analyzed by photodetectors, providing information of, e.g., hydrodynamic size changes of the magnetic labels. Optomagnetic sensing mechanisms can suppress the noise (by performing lock-in detection), accelerate the reaction (by magnetic force-enhanced molecular collision), and facilitate homogeneous/volumetric detection. Moreover, optomagnetic sensing can be performed using a low magnetic field (<10 mT) without sophisticated light sources or pickup coils, further enhancing its applicability for point-of-care tests. This review concentrates on optomagnetic biosensing techniques of different concepts classified by the magnetic actuation strategy, i.e., magnetic field-enhanced agglutination, rotating magnetic field-based particle rotation, and oscillating magnetic field-induced Brownian relaxation. Optomagnetic sensing principles applied with different actuation strategies are introduced as well. For each representative optomagnetic biosensor, a simple immunoassay strategy-based application is introduced (if possible) for methodological comparison. Thereafter, challenges and perspectives are discussed, including minimization of nonspecific binding, on-chip integration, and multiplex detection, all of which are key requirements in point-of-care diagnostics.
Collapse
Affiliation(s)
- Xiaozhou Xiao
- Department of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha Hunan, 410013, China
| | - Chuqi Yuan
- Department of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha Hunan, 410013, China
| | - Tingting Li
- Department of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha Hunan, 410013, China
| | - Jeppe Fock
- Blusense Diagnostics ApS, Fruebjergvej 3, DK-2100, Copenhagen, Denmark
| | - Peter Svedlindh
- Department of Materials Science and Engineering, Uppsala University, Box 35, SE-751 03, Uppsala, Sweden
| | - Bo Tian
- Department of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha Hunan, 410013, China.
| |
Collapse
|
32
|
Laha S, Bandopadhyay A, Chakraborty S. Smartphone-Integrated Label-Free Rapid Screening of Anemia from the Pattern Formed by One Drop of Blood on a Wet Paper Strip. ACS Sens 2022; 7:2028-2036. [PMID: 35802863 DOI: 10.1021/acssensors.2c00806] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Screening of anemic patients poses demanding challenges in extreme point-of-care settings where the gold standard diagnostic technologies are not pragmatic and the alternative point-of-care technologies suffer from compromised accuracy, prohibitive cost, process complexity, or reagent stability issues. As a disruption to this paradigm, here, we report the development of a smartphone-based sensor for rapid screening of anemic patients by exploiting the patterns formed by a spreading drop of blood on a wet paper strip wherein blood attempts to displace a more viscous fluid, on the porous matrix of a paper, leading to "finger-like" projections at the interface. We analyze the topological features of the pattern via smartphone-enabled image analytics and map the same with the relative occupancy of the red blood cells in the blood sample, allowing for label-free screening and classification of blood samples corresponding to moderate to severe anemic conditions. The accuracy of detection is verified by comparing with gold standard reports of hematology analyzer, showing a strong correlation coefficient (R2) of 0.975. This technique is likely to provide a crucial decision-making tool that obviates delicate reagents and skilled technicians for supreme functionality in resource-limited settings.
Collapse
Affiliation(s)
- Sampad Laha
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, West Bengal, India
| | - Aditya Bandopadhyay
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, West Bengal, India
| | - Suman Chakraborty
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, West Bengal, India
| |
Collapse
|
33
|
Zhang T, Ding F, Yang Y, Zhao G, Zhang C, Wang R, Huang X. Research Progress and Future Trends of Microfluidic Paper-Based Analytical Devices in In-Vitro Diagnosis. BIOSENSORS 2022; 12:485. [PMID: 35884289 PMCID: PMC9313202 DOI: 10.3390/bios12070485] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 06/30/2022] [Accepted: 07/01/2022] [Indexed: 12/14/2022]
Abstract
In vitro diagnosis (IVD) has become a hot topic in laboratory research and achievement transformation. However, due to the high cost, and time-consuming and complex operation of traditional technologies, some new technologies are being introduced into IVD, to solve the existing problems. As a result, IVD has begun to develop toward point-of-care testing (POCT), a subdivision field of IVD. The pandemic has made governments and health institutions realize the urgency of accelerating the development of POCT. Microfluidic paper-based analytical devices (μPADs), a low-cost, high-efficiency, and easy-to-operate detection platform, have played a significant role in advancing the development of IVD. μPADs are composed of paper as the core material, certain unique substances as reagents for processing the paper, and sensing devices, as auxiliary equipment. The published reviews on the same topic lack a comprehensive and systematic introduction to μPAD classification and research progress in IVD segmentation. In this paper, we first briefly introduce the origin of μPADs and their role in promoting IVD, in the introduction section. Then, processing and detection methods for μPADs are summarized, and the innovative achievements of μPADs in IVD are reviewed. Finally, we discuss and prospect the upgrade and improvement directions of μPADs, in terms of portability, sensitivity, and automation, to help researchers clarify the progress and overcome the difficulties in subsequent μPAD research.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Xiaowen Huang
- State Key Laboratory of Biobased Material and Green Papermaking, School of Bioengineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China; (T.Z.); (F.D.); (Y.Y.); (G.Z.); (C.Z.); (R.W.)
| |
Collapse
|
34
|
Point-of-Care Testing Blood Coagulation Detectors Using a Bio-Microfluidic Device Accompanied by Raman Spectroscopy. COATINGS 2022. [DOI: 10.3390/coatings12070893] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
An efficient technique was developed for the detection of human blood coagulation using a bio-microfluidic device based on Raman spectra [...]
Collapse
|
35
|
Landry V, Coburn P, Kost K, Liu X, Li-Jessen NYK. Diagnostic Accuracy of Liquid Biomarkers in Airway Diseases: Toward Point-of-Care Applications. Front Med (Lausanne) 2022; 9:855250. [PMID: 35733871 PMCID: PMC9207186 DOI: 10.3389/fmed.2022.855250] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Accepted: 05/04/2022] [Indexed: 12/30/2022] Open
Abstract
Background Liquid biomarkers have shown increasing utility in the clinical management of airway diseases. Salivary and blood samples are particularly amenable to point-of-care (POC) testing due to simple specimen collection and processing. However, very few POC tests have successfully progressed to clinical application due to the uncertainty and unpredictability surrounding their diagnostic accuracy. Objective To review liquid biomarkers of airway diseases with well-established diagnostic accuracies and discuss their prospects for future POC applications. Methodology A literature review of publications indexed in Medline or Embase was performed to evaluate the diagnostic accuracy of liquid biomarkers for chronic obstructive pulmonary disease (COPD), asthma, laryngopharyngeal reflux (LPR), and COVID-19. Results Of 3,628 studies, 71 fulfilled the inclusion criteria. Sputum and blood eosinophils were the most frequently investigated biomarkers for the management of asthma and COPD. Salivary pepsin was the only biomarker with a well-documented accuracy for the diagnosis of LPR. Inflammatory blood biomarkers (e.g., CRP, D-dimers, ferritin) were found to be useful to predict the severity, complications, and mortality related to COVID-19 infection. Conclusion Multiple liquid biomarkers have well-established diagnostic accuracies and are thus amenable to POC testing in clinical settings.
Collapse
Affiliation(s)
- Vivianne Landry
- Faculty of Medicine, University of Montreal, Montreal, QC, Canada
- School of Communication Sciences & Disorders, McGill University, Montreal, QC, Canada
| | - Patrick Coburn
- School of Communication Sciences & Disorders, McGill University, Montreal, QC, Canada
| | - Karen Kost
- Department of Otolaryngology-Head & Neck Surgery, McGill University, Montreal, QC, Canada
| | - Xinyu Liu
- Department of Mechanical & Industrial Engineering, University of Toronto, Toronto, ON, Canada
| | - Nicole Y. K. Li-Jessen
- School of Communication Sciences & Disorders, McGill University, Montreal, QC, Canada
- Department of Otolaryngology-Head & Neck Surgery, McGill University, Montreal, QC, Canada
- Department of Biomedical Engineering, McGill University, Montreal, QC, Canada
- The Research Institute of the McGill University Health Centre, Montreal, QC, Canada
| |
Collapse
|
36
|
Bollu TK, Parimi DS, Bhatt CS, Suresh AK. Fish-scale waste to portable bioactive discs: a sustainable platform for sensitive and reliable blood group analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:1946-1955. [PMID: 35506745 DOI: 10.1039/d2ay00128d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Blood group analysis has evolved from conventional "test-tube" to ingenious "lab-on-a-chip" micro/paper-fluidic devices for identifying blood phenotypes. Despite the rapid and economical fabrication of these devices, they require Whatman paper that is obtained by cutting down trees and plastic usage involving complex and sophisticated facilities, making scalable manufacturing laborious and expensive. Most importantly, deforestation and plastic incineration pose great threats to the biotic and abiotic environments. Here, we have developed a blood grouping strip utilizing fish-scale waste and household cardboard-waste generated origami as an affordable and sustainable strategy. The naturally inherited hydrophilicity of fish scale with a contact angle of 89° could succinctly auto-stabilize low-volume antisera without the aid of additives. Moreover, unlike paperfluidics, antisera absorption, as well as RBC-antisera agglutination upon blood introduction, happens on the spot with no capillary wicking. The merits of our technique are: it requires a low amount of blood (3 μL), eliminates additional image processing and assays, is equipment-free, and aids accurate blood typing as a visual hemagglutination readout. Additionally, a high tensile strength of ∼85 ± 5 MPa and the shelf-endurance of the bio-disc allowed us to use the simplest cardboard origami as a shield, obviating plastic and fiber generated fancy shields, making our device portable and simultaneously biodegradable. Our novel bio-disc blood analysis was tested with anonymous blood samples (n = 200), with an accuracy comparable to a standard blood group assay. This zero-cost paper, plastic-free eco-friendly blood group analyser derived from biodegradable food and cardboard waste as a resourceful technique has huge potential in various sensors and point-of-care diagnostics, especially in impoverished areas with limited or no lab facilities.
Collapse
Affiliation(s)
- Tharun K Bollu
- Bionanotechnology and Sustainable Laboratory, Department of Biological Sciences, School of Engineering and Applied Sciences, SRM University-AP, Amaravati-522503, India.
| | - Divya S Parimi
- Bionanotechnology and Sustainable Laboratory, Department of Biological Sciences, School of Engineering and Applied Sciences, SRM University-AP, Amaravati-522503, India.
| | - Chandra S Bhatt
- Bionanotechnology and Sustainable Laboratory, Department of Biological Sciences, School of Engineering and Applied Sciences, SRM University-AP, Amaravati-522503, India.
- Department of Biotechnology, FS&H, SRMIST, Kattankulathur, Chennai-603203, India
| | - Anil K Suresh
- Bionanotechnology and Sustainable Laboratory, Department of Biological Sciences, School of Engineering and Applied Sciences, SRM University-AP, Amaravati-522503, India.
| |
Collapse
|
37
|
He G, Dong T, Yang Z, Branstad A, Huang L, Jiang Z. Point-of-care COPD diagnostics: biomarkers, sampling, paper-based analytical devices, and perspectives. Analyst 2022; 147:1273-1293. [PMID: 35113085 DOI: 10.1039/d1an01702k] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Chronic obstructive pulmonary disease (COPD) has become the third leading cause of global death. Insufficiency in early diagnosis and treatment of COPD, especially COPD exacerbations, leads to a tremendous economic burden and medical costs. A cost-effective and timely prevention requires decentralized point-of-care diagnostics at patients' residences at affordable prices. Advances in point-of-care (POC) diagnostics may offer new solutions to reduce medical expenditures by measuring salivary and blood biomarkers. Among them, paper-based analytical devices have been the most promising candidates due to their advantages of being affordable, biocompatible, disposable, scalable, and easy to modify. In this review, we present salivary and blood biomarkers related to COPD endotypes and exacerbations, summarize current technologies to collect human whole saliva and whole blood samples, evaluate state-of-the-art paper-based analytical devices that detect COPD biomarkers in saliva and blood, and discuss existing challenges with outlooks on future paper-based POC systems for COPD diagnosis and management.
Collapse
Affiliation(s)
- Guozhen He
- Chongqing Key Laboratory of Micro-Nano Systems and Smart Transduction, Chongqing Key Laboratory of Colleges and Universities on Micro-Nano Systems Technology and Smart Transducing, Collaborative Innovation Center on Micro-Nano Transduction and Intelligent Eco-Internet of Things, Chongqing Academician and Expert Workstation, Chongqing Technology and Business University, Nan'an District, Chongqing 400067, China.,Department of Microsystems (IMS), Faculty of Technology, Natural Sciences and Maritime Sciences, University of South-Eastern Norway, Postboks 235, 3603 Kongsberg, Norway.
| | - Tao Dong
- Department of Microsystems (IMS), Faculty of Technology, Natural Sciences and Maritime Sciences, University of South-Eastern Norway, Postboks 235, 3603 Kongsberg, Norway.
| | - Zhaochu Yang
- Chongqing Key Laboratory of Micro-Nano Systems and Smart Transduction, Chongqing Key Laboratory of Colleges and Universities on Micro-Nano Systems Technology and Smart Transducing, Collaborative Innovation Center on Micro-Nano Transduction and Intelligent Eco-Internet of Things, Chongqing Academician and Expert Workstation, Chongqing Technology and Business University, Nan'an District, Chongqing 400067, China
| | - Are Branstad
- University of Southeast Norway (USN), School of Business, Box 235, 3603 Kongsberg, Norway
| | - Lan Huang
- Chongqing Key Laboratory of Micro-Nano Systems and Smart Transduction, Chongqing Key Laboratory of Colleges and Universities on Micro-Nano Systems Technology and Smart Transducing, Collaborative Innovation Center on Micro-Nano Transduction and Intelligent Eco-Internet of Things, Chongqing Academician and Expert Workstation, Chongqing Technology and Business University, Nan'an District, Chongqing 400067, China
| | - Zhuangde Jiang
- Chongqing Key Laboratory of Micro-Nano Systems and Smart Transduction, Chongqing Key Laboratory of Colleges and Universities on Micro-Nano Systems Technology and Smart Transducing, Collaborative Innovation Center on Micro-Nano Transduction and Intelligent Eco-Internet of Things, Chongqing Academician and Expert Workstation, Chongqing Technology and Business University, Nan'an District, Chongqing 400067, China
| |
Collapse
|
38
|
Wan Y, Zong C, Li X, Wang A, Li Y, Yang T, Bao Q, Dubow M, Yang M, Rodrigo LA, Mao C. New Insights for Biosensing: Lessons from Microbial Defense Systems. Chem Rev 2022; 122:8126-8180. [PMID: 35234463 DOI: 10.1021/acs.chemrev.1c01063] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Microorganisms have gained defense systems during the lengthy process of evolution over millions of years. Such defense systems can protect them from being attacked by invading species (e.g., CRISPR-Cas for establishing adaptive immune systems and nanopore-forming toxins as virulence factors) or enable them to adapt to different conditions (e.g., gas vesicles for achieving buoyancy control). These microorganism defense systems (MDS) have inspired the development of biosensors that have received much attention in a wide range of fields including life science research, food safety, and medical diagnosis. This Review comprehensively analyzes biosensing platforms originating from MDS for sensing and imaging biological analytes. We first describe a basic overview of MDS and MDS-inspired biosensing platforms (e.g., CRISPR-Cas systems, nanopore-forming proteins, and gas vesicles), followed by a critical discussion of their functions and properties. We then discuss several transduction mechanisms (optical, acoustic, magnetic, and electrical) involved in MDS-inspired biosensing. We further detail the applications of the MDS-inspired biosensors to detect a variety of analytes (nucleic acids, peptides, proteins, pathogens, cells, small molecules, and metal ions). In the end, we propose the key challenges and future perspectives in seeking new and improved MDS tools that can potentially lead to breakthrough discoveries in developing a new generation of biosensors with a combination of low cost; high sensitivity, accuracy, and precision; and fast detection. Overall, this Review gives a historical review of MDS, elucidates the principles of emulating MDS to develop biosensors, and analyzes the recent advancements, current challenges, and future trends in this field. It provides a unique critical analysis of emulating MDS to develop robust biosensors and discusses the design of such biosensors using elements found in MDS, showing that emulating MDS is a promising approach to conceptually advancing the design of biosensors.
Collapse
Affiliation(s)
- Yi Wan
- State Key Laboratory of Marine Resource Utilization in the South China Sea, School of Pharmaceutical Sciences, Marine College, Hainan University, Haikou 570228, P. R. China
| | - Chengli Zong
- State Key Laboratory of Marine Resource Utilization in the South China Sea, School of Pharmaceutical Sciences, Marine College, Hainan University, Haikou 570228, P. R. China
| | - Xiangpeng Li
- Department of Bioengineering and Therapeutic Sciences, Schools of Medicine and Pharmacy, University of California, San Francisco, 1700 Fourth Street, Byers Hall 303C, San Francisco, California 94158, United States
| | - Aimin Wang
- State Key Laboratory of Marine Resource Utilization in the South China Sea, School of Pharmaceutical Sciences, Marine College, Hainan University, Haikou 570228, P. R. China
| | - Yan Li
- College of Animal Science, Zhejiang University, Hangzhou, Zhejiang 310058, P. R. China
| | - Tao Yang
- School of Materials Science and Engineering, Zhejiang University, Hangzhou, Zhejiang 310058, P. R. China
| | - Qing Bao
- School of Materials Science and Engineering, Zhejiang University, Hangzhou, Zhejiang 310058, P. R. China
| | - Michael Dubow
- Institute for Integrative Biology of the Cell (I2BC), UMR 9198 CNRS, CEA, Université Paris-Saclay, Campus C.N.R.S, Bâtiment 12, Avenue de la Terrasse, 91190 Gif-sur-Yvette, France
| | - Mingying Yang
- College of Animal Science, Zhejiang University, Hangzhou, Zhejiang 310058, P. R. China
| | - Ledesma-Amaro Rodrigo
- Imperial College Centre for Synthetic Biology, Department of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom
| | - Chuanbin Mao
- Department of Chemistry & Biochemistry, Stephenson Life Science Research Center, University of Oklahoma, 101 Stephenson Parkway, Norman, Oklahoma 73019, United States.,School of Materials Science and Engineering, Zhejiang University, Hangzhou, Zhejiang 310058, P. R. China
| |
Collapse
|
39
|
Boegner DJ, Everitt ML, White IM. Thermally Responsive Alkane Partitions for Assay Automation. ACS APPLIED MATERIALS & INTERFACES 2022; 14:8865-8875. [PMID: 35147027 PMCID: PMC10044609 DOI: 10.1021/acsami.2c00493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
For point-of-care diagnostic tools to be impactful, they must be inexpensive, equipment-free, and sample-to-answer (i.e., require no user intervention). Here, we report a new approach to enable sample-to-answer diagnostics that utilizes thermally responsive alkane partitions (TRAPs) as automated pseudo-valves. When combined with the magnetic manipulation of microbeads, TRAPs enable the pumpless automation of all steps in complex assays. We demonstrate that in relatively narrow channel geometries, liquified alkane partitions continue to separate reagents on each side of the partition while enabling the transition of magnetic beads from one reagent to the next, replacing manual pipetting steps in conventional assays. In addition, we show that in relatively broader geometries, liquified partitions breach, enabling the addition/mixing of preloaded reagents. Through calculation and experimentation, we determine the geometric design rules for implementing the stationary and removable partitions in fluidic channels. In addition, we demonstrate that magnetic microbeads can be pulled through liquified stationary TRAPs without disrupting partition integrity and without disrupting bound protein complexes attached at the microbead surface. The TRAP technology introduced here can enable a new low-cost and equipment-free approach for fully automated sample-to-answer diagnostics.
Collapse
Affiliation(s)
- David J Boegner
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, Maryland 20742, United States
| | - Micaela L Everitt
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, Maryland 20742, United States
| | - Ian M White
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, Maryland 20742, United States
| |
Collapse
|
40
|
Weng X, Fu Z, Zhang C, Jiang W, Jiang H. A Portable 3D Microfluidic Origami Biosensor for Cortisol Detection in Human Sweat. Anal Chem 2022; 94:3526-3534. [PMID: 35170939 DOI: 10.1021/acs.analchem.1c04508] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Analysis of cortisol levels in human sweat is increasingly important as it can be a "stress biomarker" in stress-related disorders, giving real-time information about human health status. In this study, a portable 3D microfluidic origami biosensor based on a smartphone was developed for cortisol-level detection in human sweat. Molybdenum disulfide (MoS2) nanosheet-mediated fluorescence resonance energy transfer (FRET) and fluorescently labeled aptamers were employed in the biosensing process. A multilayer-structured 3D origami microfluidic chip was fabricated and functionalized to facilitate low-volume perspired human sweat collection, transportation, and detection. The translatability of the biosensor was exhibited by the fluorescence analysis in a smartphone mounted in a custom-designed holder. The critical design parameters of the microfluidic origami biosensor, including the characterization of various paper substrates, the concentration of MoS2 nanosheets, and the incubation/reaction time, were adjusted to obtain an acceptable range for the assay dynamic range and limit of detection (LOD). Under optimum conditions, various doses of cortisol within the physiologically relevant range of 10-1000 ng/mL reported in human sweat were tested to evaluate the performance of the proposed biosensor. It displayed an LOD of 6.76 ng/mL at 3σ in artificial sweat, an analysis time of 25 min, and high selectivity. The performance of the proposed cortisol sensor was compared with an enzyme-linked immunosorbent assay (ELISA) for a spiked artificial sweat sample, and a correlation coefficient of 0.988 was found. The proposed biosensor also presented satisfactory results in the determination of the cortisol levels in a real human sweat sample. The resulting portable biosensor provides a rapid, low-cost, convenient, and non-invasive sensing solution for the point-of-care analysis of cortisol levels in sweat.
Collapse
Affiliation(s)
- Xuan Weng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 611731, China.,Institute of Electronic and Information Engineering of UESTC in Guangdong, Dongguan, Guangdong 523808, China
| | - Zhuoyi Fu
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 611731, China
| | - Cheng Zhang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 611731, China
| | - Wen Jiang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 611731, China
| | - Hai Jiang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 611731, China.,Institute of Electronic and Information Engineering of UESTC in Guangdong, Dongguan, Guangdong 523808, China
| |
Collapse
|
41
|
Hang Y, Boryczka J, Wu N. Visible-light and near-infrared fluorescence and surface-enhanced Raman scattering point-of-care sensing and bio-imaging: a review. Chem Soc Rev 2022; 51:329-375. [PMID: 34897302 PMCID: PMC9135580 DOI: 10.1039/c9cs00621d] [Citation(s) in RCA: 109] [Impact Index Per Article: 36.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
This review article deals with the concepts, principles and applications of visible-light and near-infrared (NIR) fluorescence and surface-enhanced Raman scattering (SERS) in in vitro point-of-care testing (POCT) and in vivo bio-imaging. It has discussed how to utilize the biological transparency windows to improve the penetration depth and signal-to-noise ratio, and how to use surface plasmon resonance (SPR) to amplify fluorescence and SERS signals. This article has highlighted some plasmonic fluorescence and SERS probes. It has also reviewed the design strategies of fluorescent and SERS sensors in the detection of metal ions, small molecules, proteins and nucleic acids. Particularly, it has provided perspectives on the integration of fluorescent and SERS sensors into microfluidic chips as lab-on-chips to realize point-of-care testing. It has also discussed the design of active microfluidic devices and non-paper- or paper-based lateral flow assays for in vitro diagnostics. In addition, this article has discussed the strategies to design in vivo NIR fluorescence and SERS bio-imaging platforms for monitoring physiological processes and disease progression in live cells and tissues. Moreover, it has highlighted the applications of POCT and bio-imaging in testing toxins, heavy metals, illicit drugs, cancers, traumatic brain injuries, and infectious diseases such as COVID-19, influenza, HIV and sepsis.
Collapse
Affiliation(s)
- Yingjie Hang
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, MA 01003-9303, USA.
| | - Jennifer Boryczka
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, MA 01003-9303, USA.
| | - Nianqiang Wu
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, MA 01003-9303, USA.
| |
Collapse
|
42
|
Dou J, Shen Q, Yang Y, Song H, Shen D. A smartphone-based device for simultaneous measurement of ratiometric fluorescence and absorbance demonstrated by the determination of hypochlorous acid. NEW J CHEM 2022. [DOI: 10.1039/d2nj03106j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Ratiometric fluorescence and absorbance are measured simultaneously by a smartphone-based device according to the corrected brightness ratio in a picture.
Collapse
Affiliation(s)
- Jianzhi Dou
- School of Applied Chemistry, Food and Drug, Weifang Engineering Vocational College, Qingzhou 262500, P. R. China
| | - Qirui Shen
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Shandong Normal University, Jinan 250014, P. R. China
| | - Yan Yang
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Shandong Normal University, Jinan 250014, P. R. China
| | - Haiyan Song
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Shandong Normal University, Jinan 250014, P. R. China
| | - Dazhong Shen
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Shandong Normal University, Jinan 250014, P. R. China
| |
Collapse
|
43
|
Samae M, Chatpun S, Chirasatitsin S. Hemagglutination Detection with Paper-Plastic Hybrid Passive Microfluidic Chip. MICROMACHINES 2021; 12:1533. [PMID: 34945381 PMCID: PMC8708700 DOI: 10.3390/mi12121533] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/04/2021] [Accepted: 12/07/2021] [Indexed: 01/21/2023]
Abstract
Hemagglutination is a critical reaction that occurs when antigens expressed on red blood cells (RBCs) react with the antibodies used for blood typing. Even though blood typing devices have been introduced to the market, they continue to face several limitations in terms of observation by the eye alone, blood manipulation difficulties, and the need for large-scale equipment, particularly process automated machines. Thus, this study aimed to design, fabricate, and test a novel hybrid passive microfluidic chip made of filter paper and polymer using a cost-effective xurography manufacturing technique. This chip is referred to as the microfluidic paper-plastic hybrid passive device (PPHD). A passive PPHD does not require external sources, such as a syringe pump. It is composed of a paper-based component that contains dried antibodies within its porous paper and a polymer component that serves as the detection zone. A single blood sample was injected into the chip's inlet, and classification was determined using the mean intensity image. The results indicated that embedded antibodies were capable of causing RBC agglutination without a saline washing step and that the results could be classified as obviously agglutination or nonagglutination for blood typing using both the naked eye and a mean intensity image. As a proof-of-concept, this study demonstrated efficiency in quantitative hemagglutination measurement within a passive PPHD for blood typing, which could be used to simplify blood biomarker analysis.
Collapse
Affiliation(s)
| | | | - Somyot Chirasatitsin
- Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai 90110, Thailand; (M.S.); (S.C.)
| |
Collapse
|
44
|
Molloy A, Harrison J, McGrath JS, Owen Z, Smith C, Liu X, Li X, Cox JAG. Microfluidics as a Novel Technique for Tuberculosis: From Diagnostics to Drug Discovery. Microorganisms 2021; 9:microorganisms9112330. [PMID: 34835455 PMCID: PMC8618277 DOI: 10.3390/microorganisms9112330] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 11/01/2021] [Accepted: 11/03/2021] [Indexed: 12/29/2022] Open
Abstract
Tuberculosis (TB) remains a global healthcare crisis, with an estimated 5.8 million new cases and 1.5 million deaths in 2020. TB is caused by infection with the major human pathogen Mycobacterium tuberculosis, which is difficult to rapidly diagnose and treat. There is an urgent need for new methods of diagnosis, sufficient in vitro models that capably mimic all physiological conditions of the infection, and high-throughput drug screening platforms. Microfluidic-based techniques provide single-cell analysis which reduces experimental time and the cost of reagents, and have been extremely useful for gaining insight into monitoring microorganisms. This review outlines the field of microfluidics and discusses the use of this novel technique so far in M. tuberculosis diagnostics, research methods, and drug discovery platforms. The practices of microfluidics have promising future applications for diagnosing and treating TB.
Collapse
Affiliation(s)
- Antonia Molloy
- School of Life and Health Sciences, Aston University, Aston Triangle, Birmingham B4 7ET, UK; (A.M.); (J.H.)
| | - James Harrison
- School of Life and Health Sciences, Aston University, Aston Triangle, Birmingham B4 7ET, UK; (A.M.); (J.H.)
| | - John S. McGrath
- Sphere Fluidics Limited, The McClintock Building, Suite 7, Granta Park, Great Abington, Cambridge CB21 6GP, UK; (J.S.M.); (Z.O.); (C.S.); (X.L.); (X.L.)
| | - Zachary Owen
- Sphere Fluidics Limited, The McClintock Building, Suite 7, Granta Park, Great Abington, Cambridge CB21 6GP, UK; (J.S.M.); (Z.O.); (C.S.); (X.L.); (X.L.)
| | - Clive Smith
- Sphere Fluidics Limited, The McClintock Building, Suite 7, Granta Park, Great Abington, Cambridge CB21 6GP, UK; (J.S.M.); (Z.O.); (C.S.); (X.L.); (X.L.)
| | - Xin Liu
- Sphere Fluidics Limited, The McClintock Building, Suite 7, Granta Park, Great Abington, Cambridge CB21 6GP, UK; (J.S.M.); (Z.O.); (C.S.); (X.L.); (X.L.)
| | - Xin Li
- Sphere Fluidics Limited, The McClintock Building, Suite 7, Granta Park, Great Abington, Cambridge CB21 6GP, UK; (J.S.M.); (Z.O.); (C.S.); (X.L.); (X.L.)
| | - Jonathan A. G. Cox
- School of Life and Health Sciences, Aston University, Aston Triangle, Birmingham B4 7ET, UK; (A.M.); (J.H.)
- Correspondence: ; Tel.: +44-121-204-5011
| |
Collapse
|
45
|
Li M, Zeng Y, Qu X, Jalalah M, Alsareii SA, Li C, Harraz FA, Li G. Biocatalytic CsPbX 3 Perovskite Nanocrystals: A Self-Reporting Nanoprobe for Metabolism Analysis. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2103255. [PMID: 34605143 DOI: 10.1002/smll.202103255] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 07/25/2021] [Indexed: 06/13/2023]
Abstract
CsPbX3 perovskite nanocrystals (NCs), with excellent optical properties, have drawn considerable attention in recent years. However, they also suffer from inherent vulnerability and hydrolysis, causing the new understanding or new applications to be difficultly explored. Herein, for the first time, it is discovered that the phospholipid membrane (PM)-coated CsPbX3 NCs have intrinsic biocatalytic activity. Different from other peroxidase-like nanozymes relying on extra chromogenic reagents, the PM-CsPbX3 NCs can be used as a self-reporting nanoprobe, allowing an "add-to-answer" detection model. Notably, the fluorescence of PM-CsPbX3 NCs can be rapidly quenched by adding H2 O2 and then be restored by removing excess H2 O2 . Initiated from this unexpected observation, the PM-CsPbX3 NCs can be explored to prepare multi-color bioinks and metabolite-responsive paper analytical devices, demonstrating the great potential of CsPbX3 NCs in bioanalysis. This is the first report on the discovery of nanozyme-like property of all-inorganic CsPbX3 perovskite NCs, which adds another piece to the nanozyme puzzle and opens new avenues for in vitro disease diagnostics.
Collapse
Affiliation(s)
- Menglu Li
- State Key Laboratory of Pharmaceutical Biotechnology, School of Life Sciences, Nanjing University, Nanjing, 210023, P. R. China
| | - Yujing Zeng
- State Key Laboratory of Pharmaceutical Biotechnology, School of Life Sciences, Nanjing University, Nanjing, 210023, P. R. China
| | - Xinyu Qu
- State Key Laboratory of Pharmaceutical Biotechnology, School of Life Sciences, Nanjing University, Nanjing, 210023, P. R. China
| | - Mohammed Jalalah
- Promising Centre for Sensors and Electronic Devices (PCSED), Advanced Materials and Nano-Research Centre, Najran University, P.O. Box: 1988, Najran, 11001, Saudi Arabia
- Department of Electrical Engineering, Faculty of Engineering, Najran University, P.O. Box: 1988, Najran, 11001, Saudi Arabia
| | - Saeed A Alsareii
- Department of Surgery, College of Medicine, Najran University, P.O. Box: 1988, Najran, 11001, Saudi Arabia
| | - Chao Li
- School of Food and Biological Engineering, Hefei University of Technology, Hefei, 230009, P. R. China
| | - Farid A Harraz
- Promising Centre for Sensors and Electronic Devices (PCSED), Advanced Materials and Nano-Research Centre, Najran University, P.O. Box: 1988, Najran, 11001, Saudi Arabia
- Nanomaterials and Nanotechnology Department, Central Metallurgical Research and Development Institute (CMRDI), P.O. 87 Helwan, Cairo, 11421, Egypt
| | - Genxi Li
- State Key Laboratory of Pharmaceutical Biotechnology, School of Life Sciences, Nanjing University, Nanjing, 210023, P. R. China
- Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai, 200444, P. R. China
| |
Collapse
|
46
|
|
47
|
Saidykhan J, Selevic L, Cinti S, May JE, Killard AJ. Paper-Based Lateral Flow Device for the Sustainable Measurement of Human Plasma Fibrinogen in Low-Resource Settings. Anal Chem 2021; 93:14007-14013. [PMID: 34615344 PMCID: PMC8529579 DOI: 10.1021/acs.analchem.1c03665] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
![]()
Fibrinogen
concentration is a major determinant of both clotting
and bleeding risk. Clotting and bleeding disorders cause extensive
morbidity and mortality, particularly in resource-poor and emergency
settings. This is exacerbated by a lack of timely intervention informed
by measurement of fibrinogen levels under conditions such as thrombosis
or postpartum haemorrhage. There is an absence of simple, rapid, low-cost,
and sustainable diagnostic devices for fibrinogen measurement that
can be deployed in such environments. Paper-based analytical devices
are of significant interest due to their potential for low-cost production,
ease of use, and environmental sustainability. In this work, a device
for measuring blood plasma fibrinogen using chromatography paper was
developed. Wax printing was used to create hydrophobic structures
to define the test channel and sample application zone. Test strips
were modified with bovine thrombin. Plasma samples (22 μL) were
applied, and the flow rate was monitored over 5 min. As the sample
traversed the strip, clotting was induced by the conversion of soluble
fibrinogen to insoluble fibrin. The flow rate and distance travelled
by the sample were dependent on fibrinogen concentration. The device
was able to measure fibrinogen concentration in the range of 0.5–7.0
± 0.3 mg/mL (p < 0.05, n = 24) and had excellent correlation with laboratory coagulometry
in artificial samples (r2 = 0.9582, n = 60). Devices were also stable at 4–6 °C
for up to 3 weeks.
Collapse
Affiliation(s)
- Jerro Saidykhan
- Centre for Research in Biosciences (CRIB), Department of Applied Sciences, University of the West of England, Coldhar-bour Lane, Bristol BS16 1QY, U.K
| | - Laura Selevic
- Centre for Research in Biosciences (CRIB), Department of Applied Sciences, University of the West of England, Coldhar-bour Lane, Bristol BS16 1QY, U.K
| | - Stefano Cinti
- Department of Pharmacy, University of Naples "Federico II", Via Domenico Montesano 49, Napoli 80131, Italy
| | - Jennifer E May
- Centre for Research in Biosciences (CRIB), Department of Applied Sciences, University of the West of England, Coldhar-bour Lane, Bristol BS16 1QY, U.K
| | - Anthony J Killard
- Centre for Research in Biosciences (CRIB), Department of Applied Sciences, University of the West of England, Coldhar-bour Lane, Bristol BS16 1QY, U.K
| |
Collapse
|
48
|
Li CY, Zheng B, Lu LL, Fang WK, Zheng MQ, Gao JL, Yuheng L, Pang DW, Tang HW. Biomimetic Chip Enhanced Time-Gated Luminescent CRISPR-Cas12a Biosensors under Functional DNA Regulation. Anal Chem 2021; 93:12514-12523. [PMID: 34490773 DOI: 10.1021/acs.analchem.1c01403] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Despite that the currently discovered CRISPR-Cas12a system is beneficial for improving the detection accuracy and design flexibility of luminescent biosensors, there are still challenges to extend target species and strengthen adaptability in complicated biological media. To conquer these obstacles, we present here some useful strategies. For the former, the limitation to nucleic acids assay is broken through by introducing a simple functional DNA regulation pathway to activate the unique trans-cleavage effect of this CRISPR system, under which the expected biosensors are capable of effectively transducing a protein (employing dual aptamers) and a metal ion (employing DNAzyme). For the latter, a time-gated luminescence resonance energy transfer imaging manner using a long-persistent nanophosphor as the energy donor is performed to completely eliminate the background interference and a nature-inspired biomimetic periodic chip constructed by photonic crystals is further combined to enhance the persistent luminescence. In line with the above efforts, the improved CRISPR-Cas12a luminescent biosensor not only exhibits a sound analysis performance toward the model targets (carcinoembryonic antigen and Na+) but also owns a strong anti-interference feature to actualize accurate sensing in human plasma samples, offering a new and applicative analytical tool for laboratory medicine.
Collapse
Affiliation(s)
- Cheng-Yu Li
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan, 430065, People's Republic of China
| | - Bei Zheng
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, People's Republic of China.,Westlake Institute for Advanced Study, School of Life Sciences, Westlake University, Hangzhou, 310024, People's Republic of China
| | - Li-Li Lu
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan, 430065, People's Republic of China.,Institute of Pharmaceutical Innovation, Medical College, Wuhan University of Science and Technology, Wuhan, 430065, People's Republic of China
| | - Wen-Kai Fang
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, People's Republic of China
| | - Ming-Qiu Zheng
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, People's Republic of China
| | - Jia-Ling Gao
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan, 430065, People's Republic of China
| | - Liu Yuheng
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan, 430065, People's Republic of China
| | - Dai-Wen Pang
- State Key Laboratory of Medicinal Chemical Biology, Tianjin Key Laboratory of Biosensing and Molecular Recognition, Research Center for Analytical Sciences, and College of Chemistry, Nankai University, Tianjin, 300071, People's Republic of China
| | - Hong-Wu Tang
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, People's Republic of China
| |
Collapse
|
49
|
Hamidon NN, Salentijn GI, Verpoorte E. Enhanced passive mixing for paper microfluidics. RSC Adv 2021; 11:25677-25685. [PMID: 34354827 PMCID: PMC8311897 DOI: 10.1039/d1ra04916j] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 07/19/2021] [Indexed: 11/21/2022] Open
Abstract
Imprecise control of fluid flows in paper-based devices is a major challenge in pushing the innovations in this area towards societal implementation. Assays on paper tend to have low reaction yield and reproducibility issues that lead to poor sensitivity and detection limits. Understanding and addressing these issues is key to improving the performance of paper-based devices. In this work, we use colorimetric analysis to observe the mixing behaviour of molecules from two parallel flow streams in unobstructed (on unpatterned paper) and constricted flow (through the gap of a patterned hourglass structure). The model system used for characterization of mixing involved the reaction of Fe3+ with SCN− to form the coloured, soluble complex Fe(SCN)2+. At all tested concentrations (equal concentrations of 50.0 mM, 25.0 mM or 12.5 mM for KSCN and FeCl3 in each experiment), the reaction yield increases (higher colorimetric signal) and better mixing is obtained (lower relative standard deviation) as the gap of the flow constriction becomes smaller (4.69–0.32 mm). This indicates enhanced passive mixing of reagents. A transition window of gap widths exhibiting no mixing enhancement (about 2 mm) to gap widths exhibiting complete mixing (0.5 mm) is defined. The implementation of gap sizes that are smaller than 0.5 mm (below the transition window) for passive mixing is suggested as a good strategy to obtain complete mixing and reproducible reaction yields on paper. In addition, the hourglass structure was used to define the ratio of reagents to be mixed (2 : 1, 1 : 1 and 1 : 2 HCl–NaOH) by simply varying the width ratio of the input channels of the paper. This allows easy adaptation of the device to reaction stoichiometry. Efficient passive mixing can be achieved by contricting the reagent flow using structures having narrow gaps.![]()
Collapse
Affiliation(s)
- Nurul Nadiah Hamidon
- Pharmaceutical Analysis, Groningen Research Institute of Pharmacy, University of Groningen 9700 AD Groningen The Netherlands +31 50 363 75 82 +31 50 363 33 37.,Faculty of Industrial Sciences and Technology, Universiti Malaysia Pahang 26300 Kuantan Malaysia
| | - Gert Ij Salentijn
- Laboratory of Organic Chemistry, Wageningen University and Research Stippeneng 4 6708 WE Wageningen The Netherlands
| | - Elisabeth Verpoorte
- Pharmaceutical Analysis, Groningen Research Institute of Pharmacy, University of Groningen 9700 AD Groningen The Netherlands +31 50 363 75 82 +31 50 363 33 37
| |
Collapse
|
50
|
Zhang X, Liu S, Wei X, Yu YL, Wang JH. A Novel Pretreatment Device Integrating Magnetic-Assisted Dispersive Extraction and Ultrasonic Spray Separation for Speciation Analysis of Arsenic in Whole Blood by Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry. Anal Chem 2021; 93:10577-10583. [PMID: 34283582 DOI: 10.1021/acs.analchem.1c01745] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Speciation analysis of arsenic in blood is essential for identifying and quantifying the exposure of arsenic and studying the metabolism and toxicity of arsenic. Herein, a novel pretreatment device is rationally designed and used for speciation analysis of arsenic in whole blood by ion chromatography-inductively coupled plasma-mass spectrometry (IC-ICP-MS). The sample centrifuge tubes containing blood, reagents, and a magnetic stir bar are placed on the fidget spinner of the pretreatment device. When flicking the fidget spinner rotation with the finger, the magnetic stir bar in the tube rotates in three dimensions under the magnetic field, thereby assisting dispersive extraction of arsenic species by the mixing of blood with reagents. Afterward, the arsenic extract is separated in situ from the blood matrix using an ultrasonic spray sheet covered with a filter and ultrafiltration membrane, which is directly used for subsequent IC-ICP-MS analysis. For 100 μL of blood, the whole pretreatment operation can be completed within 10 min. With As(III), As(V), MMA, and DMA in blood as analytes, the use of the present pretreatment device will hardly lead to the loss and transformation of arsenic species, and the extraction efficiency of the total arsenic is more than 96%. When the pretreatment device is coupled to IC-ICP-MS, the detection limits of four arsenic species in whole blood are 0.017-0.023 μg L-1, and precisions are within 2.3-4.2%. This pretreatment device provides a simple, fast, efficient, and low-cost tool for extraction and separation of arsenic species in whole blood, opening a new idea for the pretreatment of complex samples.
Collapse
Affiliation(s)
- Xiao Zhang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Shuang Liu
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Xing Wei
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Yong-Liang Yu
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Jian-Hua Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| |
Collapse
|