1
|
Cheng Y, Li X, Gu P, Mao R, Zou Y, Tong L, Li Z, Fan Y, Zhang X, Liang J, Sun Y. Hierarchical Scaffold with Directional Microchannels Promotes Cell Ingrowth for Bone Regeneration. Adv Healthc Mater 2024; 13:e2303600. [PMID: 38303119 DOI: 10.1002/adhm.202303600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 01/06/2024] [Indexed: 02/03/2024]
Abstract
Bone regenerative scaffolds with a bionic natural bone hierarchical porous structure provide a suitable microenvironment for cell migration and proliferation. Here, a bionic scaffold (DP-PLGA/HAp) with directional microchannels is prepared by combining 3D printing and directional freezing technology. The 3D printed framework provides structural support for new bone tissue growth, while the directional pore embedded in the scaffolds provides an express lane for cell migration and nutrition transport, facilitating cell growth and differentiation. The hierarchical porous scaffolds achieve rapid infiltration and adhesion of bone marrow mesenchymal stem cells (BMSCs) and improve the expression of osteogenesis-related genes. The rabbit cranial defect experiment presents significant new bone formation, demonstrating that DP-PLGA/HAp offers an effective means to guide cranial bone regeneration. The combination of 3D printing and directional freezing technology might be a promising strategy for developing bone regenerative biomaterials.
Collapse
Affiliation(s)
- Yaling Cheng
- National Engineering Research Center for Biomaterials, Sichuan University, 29# Wangjiang Road, Chengdu, 610064, China
| | - Xing Li
- National Engineering Research Center for Biomaterials, Sichuan University, 29# Wangjiang Road, Chengdu, 610064, China
| | - Peiyang Gu
- National Engineering Research Center for Biomaterials, Sichuan University, 29# Wangjiang Road, Chengdu, 610064, China
| | - Ruiqi Mao
- College of Materials Science and Engineering, Sichuan University, 29# Wangjiang Road, Chengdu, 610064, China
| | - Yaping Zou
- National Engineering Research Center for Biomaterials, Sichuan University, 29# Wangjiang Road, Chengdu, 610064, China
| | - Lei Tong
- National Engineering Research Center for Biomaterials, Sichuan University, 29# Wangjiang Road, Chengdu, 610064, China
| | - Zhulian Li
- National Engineering Research Center for Biomaterials, Sichuan University, 29# Wangjiang Road, Chengdu, 610064, China
| | - Yujiang Fan
- National Engineering Research Center for Biomaterials, Sichuan University, 29# Wangjiang Road, Chengdu, 610064, China
| | - Xingdong Zhang
- National Engineering Research Center for Biomaterials, Sichuan University, 29# Wangjiang Road, Chengdu, 610064, China
| | - Jie Liang
- National Engineering Research Center for Biomaterials, Sichuan University, 29# Wangjiang Road, Chengdu, 610064, China
- Sichuan Testing Center for Biomaterials and Medical Devices, Sichuan University, 29# Wangjiang Road, Chengdu, 610064, China
| | - Yong Sun
- National Engineering Research Center for Biomaterials, Sichuan University, 29# Wangjiang Road, Chengdu, 610064, China
| |
Collapse
|
2
|
Chen J, Qian Y, Li H, Zuo W, Sun W, Xing D, Zhou X. Lysophosphatidic Acid/Polydopamine-Modified nHA Composite Scaffolds for Enhanced Osteogenesis via Upregulating the Wnt/Beta-Catenin Pathway. ACS APPLIED MATERIALS & INTERFACES 2024; 16:13466-13480. [PMID: 38445450 DOI: 10.1021/acsami.3c16545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/07/2024]
Abstract
Guided bone regeneration (GBR) technology has been widely used for the regeneration of periodontal bone defects. However, the limited mechanical properties and bone regeneration potential of the currently available GBR membranes often limit their repair effectiveness. In this paper, serum-derived growth factor lysophosphatidic acid (LPA) nanoparticles and dopamine-decorative nanohydroxyapatite (pDA/nHA) particles were double-loaded into polylactic-glycolic acid/polycaprolactone (PLGA/PCL) scaffolds as an organic/inorganic biphase delivery system, namely, PP-pDA/nHA-LPA scaffolds. Physicochemical properties and osteogenic ability in vitro and in vivo were performed. Scanning electron microscopy and mechanical tests showed that the PP-pDA/nHA-LPA scaffolds had a 3D bionic scaffold structure with improved mechanical properties. In vitro cell experiments demonstrated that the PP-pDA/nHA-LPA scaffolds could significantly enhance the attachment, proliferation, osteogenic differentiation, and mineralization of MC3T3-E1 cells. In vivo, the PP-pDA/nHA-LPA scaffolds exhibited great cytocompatibility and cell recruitment ability in 2- and 4-week subcutaneous implantation experiments and significantly promoted bone regeneration in the periodontal defect scaffold implantation experiment. Moreover, LPA-loaded scaffolds were confirmed to enhance osteogenic activities by upregulating the expression of β-catenin and further activating the Wnt/β-catenin pathway. These results demonstrate that the biphase PP-pDA/nHA-LPA delivery system is a promising material for the GBR.
Collapse
Affiliation(s)
- Jiahong Chen
- Department of Stomatology, The Fourth Affiliated Hospital of Soochow University, Suzhou Dushu Lake Hospital, Medical Center of Soochow University, Suzhou 215123, People's Republic of China
- Center of Stomatology, The Second Affiliated Hospital of Soochow University, Suzhou 215004, People's Republic of China
| | - Yunzhu Qian
- Department of Stomatology, The Fourth Affiliated Hospital of Soochow University, Suzhou Dushu Lake Hospital, Medical Center of Soochow University, Suzhou 215123, People's Republic of China
- Center of Stomatology, The Second Affiliated Hospital of Soochow University, Suzhou 215004, People's Republic of China
| | - Heng Li
- State Key Laboratory of Bioelectronics, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, People's Republic of China
| | - Wei Zuo
- Center of Stomatology, The Second Affiliated Hospital of Soochow University, Suzhou 215004, People's Republic of China
| | - Wentao Sun
- Nano Science and Technology Institute, University of Science and Technology of China, Suzhou 215123, People's Republic of China
| | - Danlei Xing
- Center of Stomatology, The Second Affiliated Hospital of Soochow University, Suzhou 215004, People's Republic of China
| | - Xuefeng Zhou
- State Key Laboratory of Bioelectronics, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, People's Republic of China
| |
Collapse
|
3
|
Li Y, Yang J, Chen X, Hu H, Lan N, Zhao J, Zheng L. Mitochondrial-targeting and NIR-responsive Mn 3O 4@PDA@Pd-SS31 nanozymes reduce oxidative stress and reverse mitochondrial dysfunction to alleviate osteoarthritis. Biomaterials 2024; 305:122449. [PMID: 38194734 DOI: 10.1016/j.biomaterials.2023.122449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 12/20/2023] [Accepted: 12/22/2023] [Indexed: 01/11/2024]
Abstract
Mitochondrial reactive oxygen species (mROS) play a crucial role in the process of osteoarthritis (OA), which may be a promising target for therapy of OA. In this study, novel mitochondrial-targeting and SOD-mimic Mn3O4@PDA@Pd-SS31 nanozymes with near-infrared (NIR) responsiveness and synergistic cascade to scavenge mROS were designed for the therapy of OA. Results showed that the nanozymes accelerated the release of Pd and Mn3O4 under NIR irradiation, exhibiting enhanced activities of SOD and CAT mimic enzymes with reversed mitochondrial dysfunction and promoted mitophagy to effectively scavenge mROS from chondrocytes, modulate the microenvironment of oxidative stress, and eventually inhibit the inflammatory response. Nanozymes were excreted in vivo through intestinal metabolic pathway and had good biocompatibility, effectively reducing the inflammatory response and relieving articular cartilage degeneration in OA joints, with a reduction of 93.7 % and 93.8 % in OARSCI scores for 4 and 8 weeks respectively. Thus, this study demonstrated that the mitochondria targeting and NIR responsive Mn3O4@PDA@Pd-SS31 nanozymes could efficiently scavenge mROS, repair damaged mitochondrial function and promote cartilage regeneration, which are promising for the treatment of OA in clinical applications.
Collapse
Affiliation(s)
- Yuquan Li
- Guangxi Engineering Center in Biomedical Materials for Tissue and Organ Regeneration, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China; Collaborative Innovation Centre of Regenerative Medicine and Medical Bioresource Development and Application, Guangxi Key Laboratory of Regenerative Medicine,The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China; Department of Orthopaedics Trauma and Hand Surgery, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China; Department of Orthopedics, The Second Affiliated Hospital of Guangxi Medical University, Nanning, 530005, China
| | - Junxu Yang
- Guangxi Engineering Center in Biomedical Materials for Tissue and Organ Regeneration, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China; Collaborative Innovation Centre of Regenerative Medicine and Medical Bioresource Development and Application, Guangxi Key Laboratory of Regenerative Medicine,The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China; Department of Orthopaedics Trauma and Hand Surgery, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China
| | - Xiaoming Chen
- Department of Spine Osteopathia, The First Affifiliated Hospital of Guangxi Medical University, Nanning, 530021, China
| | - Hao Hu
- Guangxi Engineering Center in Biomedical Materials for Tissue and Organ Regeneration, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China; Collaborative Innovation Centre of Regenerative Medicine and Medical Bioresource Development and Application, Guangxi Key Laboratory of Regenerative Medicine,The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China; Xiangyang Central Hospital, Affiliated Hospital of Hubei University of Arts and Science, Xiangyang, 441100, China
| | - Nihan Lan
- Guangxi Engineering Center in Biomedical Materials for Tissue and Organ Regeneration, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China; Collaborative Innovation Centre of Regenerative Medicine and Medical Bioresource Development and Application, Guangxi Key Laboratory of Regenerative Medicine,The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China; Life Sciences Institute, Guangxi Medical University, Nanning, 530021, China.
| | - Jinmin Zhao
- Guangxi Engineering Center in Biomedical Materials for Tissue and Organ Regeneration, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China; Collaborative Innovation Centre of Regenerative Medicine and Medical Bioresource Development and Application, Guangxi Key Laboratory of Regenerative Medicine,The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China; Department of Orthopaedics Trauma and Hand Surgery, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China.
| | - Li Zheng
- Guangxi Engineering Center in Biomedical Materials for Tissue and Organ Regeneration, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China; Collaborative Innovation Centre of Regenerative Medicine and Medical Bioresource Development and Application, Guangxi Key Laboratory of Regenerative Medicine,The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China.
| |
Collapse
|
4
|
Jin X, Xie D, Zhang Z, Liu A, Wang M, Dai J, Wang X, Deng H, Liang Y, Zhao Y, Wen P, Li Y. In vitro and in vivo studies on biodegradable Zn porous scaffolds with a drug-loaded coating for the treatment of infected bone defect. Mater Today Bio 2024; 24:100885. [PMID: 38169782 PMCID: PMC10758886 DOI: 10.1016/j.mtbio.2023.100885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 11/17/2023] [Accepted: 11/27/2023] [Indexed: 01/05/2024] Open
Abstract
Additively manufactured biodegradable zinc (Zn) scaffolds have great potential to repair infected bone defects due to their osteogenic and antibacterial properties. However, the enhancement of antibacterial properties depends on a high concentration of dissolved Zn2+, which in return deteriorates osteogenic activity. In this study, a vancomycin (Van)-loaded polydopamine (PDA) coating was prepared on pure Zn porous scaffolds to solve the above dilemma. Compared with pure Zn scaffolds according to comprehensive in vitro tests, the PDA coating resulted in a slow degradation and inhibited the excessive release of Zn2+ at the early stage, thus improving cytocompatibility and osteogenic activity. Meanwhile, the addition of Van drug substantially suppressed the attachment and proliferation of S. aureus and E. coli bacterial. Furthermore, in vivo implantation confirmed the simultaneously improved osteogenic and antibacterial functions by using the pure Zn scaffolds with Van-loaded PDA coating. Therefore, it is promising to employ biodegradable Zn porous scaffolds with the proposed drug-loaded coating for the treatment of infected bone defects.
Collapse
Affiliation(s)
- Xiang Jin
- Postgraduate Training Base, Jinzhou Medical University and The Fourth Medical Centre, Chinese PLA General Hospital, Beijing, 10048, China
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| | - Dongxu Xie
- State Key Laboratory of Tribology in Advanced Equipment, Beijing, 100084, China
- Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China
| | - Zhenbao Zhang
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| | - Aobo Liu
- State Key Laboratory of Tribology in Advanced Equipment, Beijing, 100084, China
- Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China
| | - Menglin Wang
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| | - Jiabao Dai
- State Key Laboratory of Tribology in Advanced Equipment, Beijing, 100084, China
- Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China
| | - Xuan Wang
- Postgraduate Training Base, Jinzhou Medical University and The Fourth Medical Centre, Chinese PLA General Hospital, Beijing, 10048, China
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| | - Huanze Deng
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| | - Yijie Liang
- Postgraduate Training Base, Jinzhou Medical University and The Fourth Medical Centre, Chinese PLA General Hospital, Beijing, 10048, China
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| | - Yantao Zhao
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
- Senior Department of Orthopedics, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
- Beijing Engineering Research Center of Orthopedics Implants, Beijing, 100048, China
| | - Peng Wen
- State Key Laboratory of Tribology in Advanced Equipment, Beijing, 100084, China
- Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China
| | - Yanfeng Li
- Postgraduate Training Base, Jinzhou Medical University and The Fourth Medical Centre, Chinese PLA General Hospital, Beijing, 10048, China
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| |
Collapse
|
5
|
Li J, Zhang J, Ye H, Wang Q, Ouyang Y, Luo Y, Gong Y. Pulmonary decellularized extracellular matrix (dECM) modified polyethylene terephthalate three-dimensional cell carriers regulate the proliferation and paracrine activity of mesenchymal stem cells. Front Bioeng Biotechnol 2024; 11:1324424. [PMID: 38260733 PMCID: PMC10800494 DOI: 10.3389/fbioe.2023.1324424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Accepted: 12/07/2023] [Indexed: 01/24/2024] Open
Abstract
Introduction: Mesenchymal stem cells (MSCs) possess a high degree of self-renewal capacity and in vitro multi-lineage differentiation potential. Decellularized materials have garnered considerable attention due to their elevated biocompatibility, reduced immunogenicity, excellent biodegradability, and the ability to partially mimic the in vivo microenvironment conducive to cell growth. To address the issue of mesenchymal stem cells losing their stem cell characteristics during two-dimensional (2D) cultivation, this study established three-dimensional cell carriers modified with lung decellularized extracellular matrix and assessed its impact on the life activities of mesenchymal stem cells. Methods: This study employed PET as a substrate material, grafting with polydopamine (PDA), and constructing a decellularized extracellular matrix (dECM) coating on its surface, thus creating the PET/PDA/dECM three-dimensional (3D) composite carrier. Subsequently, material characterization of the cellular carriers was conducted, followed by co-culturing with human umbilical cord mesenchymal stem cells in vitro, aiming to investigate the material's impact on the proliferation and paracrine activity of mesenchymal stem cells. Results and Discussion: Material characterization demonstrated successful grafting of PDA and dECM materials, and it had complete hydrophilicity, high porosity, and excellent mechanical properties. The material was rich in various ECM proteins (collagen I, collagen IV , laminin, fibronectin, elastin), indicating good biocompatibility. In long-term in vitro cultivation (14 days) experiments, the PET/PDA/dECM three-dimensional composite carrier significantly enhanced adhesion and proliferation of human umbilical cord-derived mesenchymal stem cells (HUCMSCs), with a proliferation rate 1.9 times higher than that of cells cultured on tissue culture polystyrene (TCPS) at day 14. Furthermore, it effectively maintained the stem cell characteristics, expressing specific antigens for HUCMSCs. Through qPCR, Western blot, and ELISA experiments, the composite carrier markedly promoted the expression and secretion of key cell factors in HUCMSCs. These results demonstrate that the PET/PDA/dECM composite carrier holds great potential for scaling up MSCs' long-term in vitro cultivation and the production of paracrine factors.
Collapse
Affiliation(s)
- Jinze Li
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen, China
| | - Jiali Zhang
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen, China
| | - Hao Ye
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen, China
| | - Qixuan Wang
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen, China
| | - Yanran Ouyang
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen, China
| | - Yuxi Luo
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen, China
- Guangdong Provincial Key Laboratory of Sensor Technology and Biomedical Instrument, Sun Yat-Sen University, Guangzhou, China
| | - Yihong Gong
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen, China
- Guangdong Provincial Key Laboratory of Sensor Technology and Biomedical Instrument, Sun Yat-Sen University, Guangzhou, China
| |
Collapse
|
6
|
Zhang J, Zhuang Y, Sheng R, Tomás H, Rodrigues J, Yuan G, Wang X, Lin K. Smart stimuli-responsive strategies for titanium implant functionalization in bone regeneration and therapeutics. MATERIALS HORIZONS 2024; 11:12-36. [PMID: 37818593 DOI: 10.1039/d3mh01260c] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/12/2023]
Abstract
With the increasing and aging of global population, there is a dramatic rise in the demand for implants or substitutes to rehabilitate bone-related disorders which can considerably decrease quality of life and even endanger lives. Though titanium and its alloys have been applied as the mainstream material to fabricate implants for load-bearing bone defect restoration or temporary internal fixation devices for bone fractures, it is far from rare to encounter failed cases in clinical practice, particularly with pathological factors involved. In recent years, smart stimuli-responsive (SSR) strategies have been conducted to functionalize titanium implants to improve bone regeneration in pathological conditions, such as bacterial infection, chronic inflammation, tumor and diabetes mellitus, etc. SSR implants can exert on-demand therapeutic and/or pro-regenerative effects in response to externally applied stimuli (such as photostimulation, magnetic field, electrical and ultrasound stimulation) or internal pathology-related microenvironment changes (such as decreased pH value, specific enzyme secreted by bacterial and excessive production of reactive oxygen species). This review summarizes recent progress on the material design and fabrication, responsive mechanisms, and in vitro and in vivo evaluations for versatile clinical applications of SSR titanium implants. In addition, currently existing limitations and challenges and further prospective directions of these strategies are also discussed.
Collapse
Affiliation(s)
- Jinkai Zhang
- Department of Oral & Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology; Research Unit of Oral and Maxillofacial Regenerative Medicine, Chinese Academy of Medical Sciences, Shanghai 200011, China.
| | - Yu Zhuang
- Department of Oral & Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology; Research Unit of Oral and Maxillofacial Regenerative Medicine, Chinese Academy of Medical Sciences, Shanghai 200011, China.
| | - Ruilong Sheng
- CQM-Centro de Quimica da Madeira, Universidade da Madeira, Campus da Penteada, 9020-105, Funchal, Madeira, Portugal.
| | - Helena Tomás
- CQM-Centro de Quimica da Madeira, Universidade da Madeira, Campus da Penteada, 9020-105, Funchal, Madeira, Portugal.
| | - João Rodrigues
- CQM-Centro de Quimica da Madeira, Universidade da Madeira, Campus da Penteada, 9020-105, Funchal, Madeira, Portugal.
| | - Guangyin Yuan
- School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
| | - Xudong Wang
- Department of Oral & Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology; Research Unit of Oral and Maxillofacial Regenerative Medicine, Chinese Academy of Medical Sciences, Shanghai 200011, China.
| | - Kaili Lin
- Department of Oral & Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology; Research Unit of Oral and Maxillofacial Regenerative Medicine, Chinese Academy of Medical Sciences, Shanghai 200011, China.
| |
Collapse
|
7
|
Zeng J, Gu C, Zeng F, Xie Y. 2D silicene nanosheets-loaded coating for combating implant-associated infection. Int J Biol Macromol 2023; 253:127585. [PMID: 37866572 DOI: 10.1016/j.ijbiomac.2023.127585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 10/01/2023] [Accepted: 10/19/2023] [Indexed: 10/24/2023]
Abstract
Implant-associated infection (IAI) is an unsolved problem in orthopaedics. Current therapies, including antibiotics and surgical debridement, can lead severe clinical and financial burdens on patients. Therefore, there is an urgent need to reinforce the inherent antibacterial properties of implants. Recently, two-dimensional (2D) silicene nanosheets (SNs) have gained increasing attention in biomedical fields owing to their considerable biocompatibility, biodegradability and strong photothermal-conversion performance. Herein, a dual-functional photosensitive coating on a Ti substrate (denoted as TPSNs) was rationally fabricated for bacterial inhibition and osteogenesis promotion. For the first time, SNs were loaded onto the surface of implants. Hyperthermia generated by the SNs and polydopamine (PDA) coating under 808 nm laser irradiation achieved the in vitro anti-bacterial efficiency of 90.7 ± 2.4 % for S. aureus and 88.0 ± 5.8 % for E. coli, respectively. In addition, TPSNs exhibited promising biocompatibility for the promotion of BMSC (bone marrow mesenchymal stem cells) proliferation and spreading. The presence of silicon (Si) in TPSNs contributed to the improved osteogenic differentiation of BMSCs, elevating the expressions of RUNX2 and OCN. In animal experiments, the combination of TPSNs with photothermal therapy (PTT) achieved an anti-bacterial efficiency of 89.2 % ± 1.6 % against S. aureus. Furthermore, TPSNs significantly improved bone-implant osseointegration in vivo. Overall, the development of a dual-functional TPSNs coating provides a new strategy for combating IAI.
Collapse
Affiliation(s)
- Junkai Zeng
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou, China
| | - Changjiang Gu
- Spine Center, Department of Orthopaedics, Changzheng Hospital, Naval Medical University (Second Military Medical University), Shanghai, China
| | - Feihui Zeng
- Department of Endocrinology, Fujian Medical University Union Hospital, Fuzhou, China
| | - Youzhuan Xie
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao tong University School of Medicine, Shanghai, China.
| |
Collapse
|
8
|
Wu M, Hong C, Shen C, Xie D, Chen T, Wu A, Li Q. Polydopamine nanomaterials and their potential applications in the treatment of autoimmune diseases. Drug Deliv 2023; 30:2289846. [PMID: 38069584 PMCID: PMC10987051 DOI: 10.1080/10717544.2023.2289846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 11/15/2023] [Indexed: 12/18/2023] Open
Abstract
The conventional treatment methods used for the management of autoimmune diseases (ADs) have limited efficacy and also exhibit significant side effects. Thus, identification of novel strategies to improve the efficacy and safety of ADs treatment is urgently required. Overactivated immune response and oxidative stress are common characteristics associated with ADs. Polydopamine (PDA), as a polymer material with good antioxidant and photothermal conversion properties, has displayed useful application potential against ADs. In addition, PDA possesses good biosafety, simple preparation, and easy functionalization, which is conducive for the pharmacological development of PDA nanomaterials with clinical transformation prospects. Here, we have first reviewed the preparation of PDA, the different functional integration strategies of PDA-based biomaterials, and their potential applications in ADs. Next, the mechanism of action of PDA in ADs has been elaborated in detail. Finally, the application opportunities and challenges linked with PDA nanomaterials for ADs treatment are discussed. This review is contributed to design reasonable and effective PDA nanomaterials for the diagnosis and treatment of ADs.
Collapse
Affiliation(s)
- Manxiang Wu
- Cixi Institute of Biomedical Engineering, International Cooperation Base of Biomedical Materials Technology and Application, Chinese Academy of Science (CAS) Key Laboratory of Magnetic Materials and Devices and Zhejiang Engineering Research Center for Biomedical Materials, Ningbo Institute of Materials Technology and Engineering, CAS, Ningbo Key Laboratory of Biomedical Imaging Probe Materials and Technology, Ningbo, China
- Department of Radiology, The Affiliated People’s Hospital of Ningbo University, Ningbo, P. R. China
| | - Chengyuan Hong
- Cixi Institute of Biomedical Engineering, International Cooperation Base of Biomedical Materials Technology and Application, Chinese Academy of Science (CAS) Key Laboratory of Magnetic Materials and Devices and Zhejiang Engineering Research Center for Biomedical Materials, Ningbo Institute of Materials Technology and Engineering, CAS, Ningbo Key Laboratory of Biomedical Imaging Probe Materials and Technology, Ningbo, China
- Department of Mechanical, Materials and Manufacturing Engineering, University of Nottingham Ningbo China, Ningbo, P. R. China
| | - Chunjuan Shen
- Center for Reproductive Medicine, Jiaxing University Affilated Maternity and Child Hospital, Jiaxing, P. R. China
| | - Dong Xie
- Cixi Institute of Biomedical Engineering, International Cooperation Base of Biomedical Materials Technology and Application, Chinese Academy of Science (CAS) Key Laboratory of Magnetic Materials and Devices and Zhejiang Engineering Research Center for Biomedical Materials, Ningbo Institute of Materials Technology and Engineering, CAS, Ningbo Key Laboratory of Biomedical Imaging Probe Materials and Technology, Ningbo, China
- Department of Radiology, The Affiliated People’s Hospital of Ningbo University, Ningbo, P. R. China
| | - Tianxiang Chen
- Cixi Institute of Biomedical Engineering, International Cooperation Base of Biomedical Materials Technology and Application, Chinese Academy of Science (CAS) Key Laboratory of Magnetic Materials and Devices and Zhejiang Engineering Research Center for Biomedical Materials, Ningbo Institute of Materials Technology and Engineering, CAS, Ningbo Key Laboratory of Biomedical Imaging Probe Materials and Technology, Ningbo, China
| | - Aiguo Wu
- Cixi Institute of Biomedical Engineering, International Cooperation Base of Biomedical Materials Technology and Application, Chinese Academy of Science (CAS) Key Laboratory of Magnetic Materials and Devices and Zhejiang Engineering Research Center for Biomedical Materials, Ningbo Institute of Materials Technology and Engineering, CAS, Ningbo Key Laboratory of Biomedical Imaging Probe Materials and Technology, Ningbo, China
| | - Qiang Li
- Department of Radiology, The Affiliated People’s Hospital of Ningbo University, Ningbo, P. R. China
| |
Collapse
|
9
|
Sang F, Pan L, Ji Z, Zhang B, Meng Z, Cao L, Zhang J, Li X, Yang X, Shi C. Polydopamine functionalized polyurethane shape memory sponge with controllable expansion performance triggered by near-infrared light for incompressible hemorrhage control. Colloids Surf B Biointerfaces 2023; 232:113590. [PMID: 37862950 DOI: 10.1016/j.colsurfb.2023.113590] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 10/06/2023] [Accepted: 10/11/2023] [Indexed: 10/22/2023]
Abstract
Uncontrolled expansion of shape memory sponges face a significant challenge in the treatment of lethal incompressible hemorrhage, which can lead to blood overflow or damage to the surrounding tissue. Herein, we developed a polydopamine functionalized polyurethane shape memory sponge (PDA-TPI-PU) with a controllable degree of expansion by near-infrared (NIR) light-triggered stimulation for the treatment of incompressible hemorrhage. The sponge has excellent liquid absorption performance and robust mechanical strength as well as good photothermal conversion ability. Under NIR light of 0.32 W/cm2, the maximum recovery rate of the fixed-shape compression sponge was 91% within 25 s in air and 80% within 25 s in blood. In the SD rat liver penetrating injury model, compared with commercial medical gelatin sponge and PVA sponge, the PDA-TPI-PU sponge could effectively control the bleeding under the NIR light irradiation and did not cause excessive compression of the wound. The sponge with these characteristics shows potential application prospects as a hemostatic material.
Collapse
Affiliation(s)
- Feng Sang
- School of Ophthalmology and Optometry, School of Biomedical Engineering, Wenzhou Medical University, Wenzhou, Zhejiang 325027, China; Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325011, China
| | - Luqi Pan
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325011, China
| | - Zhixiao Ji
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325011, China
| | - Bingxu Zhang
- School of Ophthalmology and Optometry, School of Biomedical Engineering, Wenzhou Medical University, Wenzhou, Zhejiang 325027, China; Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325011, China
| | - Zhizhen Meng
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325011, China; The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang 325000, China
| | - Lina Cao
- School of Ophthalmology and Optometry, School of Biomedical Engineering, Wenzhou Medical University, Wenzhou, Zhejiang 325027, China; Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325011, China
| | - Jing Zhang
- College of Materials Science and Engineering, Donghua University, Shanghai 200051, China
| | - Xujian Li
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325011, China.
| | - Xiao Yang
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325011, China.
| | - Changcan Shi
- School of Ophthalmology and Optometry, School of Biomedical Engineering, Wenzhou Medical University, Wenzhou, Zhejiang 325027, China; Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325011, China; The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang 325000, China.
| |
Collapse
|
10
|
Davaie S, Hooshmand T, Najafi F, Haghbin Nazarpak M, Pirmoradian M. Synthesis, Characterization, and Induced Osteogenic Differentiation Effect of Collagen Membranes Functionalized by Polydopamine/Graphene Oxide for Bone Tissue Engineering. ACS APPLIED BIO MATERIALS 2023; 6:4629-4644. [PMID: 37930634 DOI: 10.1021/acsabm.3c00400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2023]
Abstract
Collagen is one of the most common natural absorbable polymers, which is widely used as a barrier membrane in biomedical fields due to its many desirable biological properties. However, absorbable membranes such as collagen have their own disadvantages such as unpredictable degradation rates, poor rigidity leading to tissue collapse, and limited osteogenic properties and cell adhesion. In this study, a modified collagen membrane with a polydopamine-graphene oxide (PDA/GO) complex was synthesized to improve the characteristics of collagen for bone tissue engineering. The successful synthesis of PDA/GO on collagen membranes was verified using X-ray photoelectron spectroscopy (XPS) and attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR). The wettability of PDA/GO-modified collagen membranes was considerably improved based on the characterization by water contact angle compared to the uncoated membranes and surface coatings solely by either PDA or GO. The modified PDA/GO coating also enhanced the mechanical properties such as tensile strength and biodegradation rate of collagen membranes. In addition, the PDA/GO coating effectively enhanced the biocompatibility of collagen membranes as verified by the enhanced proliferation and adhesion of human bone marrow stem cells (hBMSCs). Additionally, the effects of PDA/GO coating on the osteogenic differentiation of hBMSCs on collagen membranes were investigated through alkaline phosphatase (ALP) activity and reverse transcription-quantitative polymerase chain reaction (RT-qPCR). The PDA/GO coating on collagen membranes resulted in a significant increase in osteogenic properties compared with the uncoated collagen membranes. According to the results of the current study, the combination of PDA and GO-modified collagen membranes could be used for bone tissue engineering and biomedical applications.
Collapse
Affiliation(s)
- Sotoudeh Davaie
- Department of Dental Biomaterials, School of Dentistry, Tehran University of Medical Sciences, Tehran 1439955991, Iran
| | - Tabassom Hooshmand
- Dental Research Center, Dentistry Research Institute/School of Dentistry, Tehran University of Medical Sciences, Tehran 1439955991, Iran
| | - Farhood Najafi
- Department of Resin and Additives, Institute for Color Science and Technology, Tehran 1668814811, Iran
| | | | - Maryam Pirmoradian
- Department of Dental Biomaterials, School of Dentistry, Tehran University of Medical Sciences, Tehran 1439955991, Iran
| |
Collapse
|
11
|
Masse M, Jimenez M, Genay S, Pettinari A, Bellayer S, Barthélémy C, Décaudin B, Blanchemain N, Odou P. Limitation of the migration of plasticizers from medical devices through treatment with low-pressure cold plasma, polydopamine coating, and annealing. Int J Pharm 2023; 646:123422. [PMID: 37722492 DOI: 10.1016/j.ijpharm.2023.123422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 09/14/2023] [Accepted: 09/15/2023] [Indexed: 09/20/2023]
Abstract
Poly(vinyl chloride) (PVC) is widely used in the manufacture of medical devices. The plasticizers added to PVC are potentially toxic for humans, likely to migrate, and thus unintentionally administered to patients. The objective of the present study was to reduce the migration of plasticizer (1,2-cyclohexanedicarboxylic acid, diisononylester (DINCH) or trioctyltrimellitate (TOTM)) from PVC by implementing a three-step surface treatment process: (i) pretreatment with low-pressure argon cold plasma, (ii) polydopamine coating, and (iii) post-treatment with cold plasma exposure or thermal treatment at 140 °C. Samples were then characterized in terms of the water contact angle (WCA) and the aspect in scanning electron microscopy. Plasticizer migration (n = 5) was measured using an HPLC technique with ultraviolet detection and found to depend on the treatment and the plasticizer. Plasticized PVC was hydrophobic, with a measured mean ± standard deviation WCA of 96.7 ± 3.6° for PVC-DINCH and 110.2 ± 5.8° for PVC-TOTM. Plasma post-treatment and thermal post-treatment were respectively associated with a mean decrease in migration of 38.3 ± 1.9% for DINCH and 61.5 ± 4.4% for TOTM. Our results are promising with regard to limiting the migration of plasticizers into the patient's blood and thus enabling the development of safer medical devices.
Collapse
Affiliation(s)
- Morgane Masse
- Univ. Lille, CHU Lille, ULR 7365 - GRITA - Groupe de Recherche sur les formes Injectables et les Technologies Associées, F-59000 Lille, France.
| | - Maude Jimenez
- Univ. Lille, CNRS, INRA, ENSCL UMR8207, UMET - Unité Matériaux et Transformations, F-59000 Lille, France; Institut Universitaire de France, 1 rue Descartes, F-75005 Paris, France
| | - Stéphanie Genay
- Univ. Lille, CHU Lille, ULR 7365 - GRITA - Groupe de Recherche sur les formes Injectables et les Technologies Associées, F-59000 Lille, France
| | - Alice Pettinari
- Univ. Lille, CHU Lille, ULR 7365 - GRITA - Groupe de Recherche sur les formes Injectables et les Technologies Associées, F-59000 Lille, France
| | - Séverine Bellayer
- Univ. Lille, CNRS, INRA, ENSCL UMR8207, UMET - Unité Matériaux et Transformations, F-59000 Lille, France
| | - Christine Barthélémy
- Univ. Lille, CHU Lille, ULR 7365 - GRITA - Groupe de Recherche sur les formes Injectables et les Technologies Associées, F-59000 Lille, France
| | - Bertrand Décaudin
- Univ. Lille, CHU Lille, ULR 7365 - GRITA - Groupe de Recherche sur les formes Injectables et les Technologies Associées, F-59000 Lille, France
| | - Nicolas Blanchemain
- Univ. Lille, Inserm, CHU Lille, U1008 - Controlled Drug Delivery Systems and Biomaterials, F-59000 Lille, France
| | - Pascal Odou
- Univ. Lille, CHU Lille, ULR 7365 - GRITA - Groupe de Recherche sur les formes Injectables et les Technologies Associées, F-59000 Lille, France
| |
Collapse
|
12
|
Ma T, Wang CX, Ge XY, Zhang Y. Applications of Polydopamine in Implant Surface Modification. Macromol Biosci 2023; 23:e2300067. [PMID: 37229654 DOI: 10.1002/mabi.202300067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 04/22/2023] [Indexed: 05/27/2023]
Abstract
There is great clinical demand for orthopedic and dental implant surface modification methods to prevent osseointegration failure and improve implant biological functions. Notably, dopamine (DA) can be polymerized to form polydopamine (PDA), which is similar to the adhesive proteins secreted by mussels, to form a stable bond between the bone surface and implants. Therefore, PDA has the potential to be used as an implant surface modification material with good hydrophilicity, roughness, morphology, mechanical strength, biocompatibility, antibacterial activity, cellular adhesion, and osteogenesis. In addition, PDA degradation releases DA into the surrounding microenvironment, which is found to play an important role in regulating DA receptors on both osteoblasts and osteoclasts during the bone remodeling process. Furthermore, the adhesion properties of PDA suggest its use as an intermediate layer in assisting other functional bone remodeling materials, such as nanoparticles, growth factors, peptides, and hydrogels, to form "dual modifications." The purpose of this review is to summarize the recent progress in research on PDA and its derivatives as orthopedic and dental implant surface modification materials and to analyze the multiple functions of PDA.
Collapse
Affiliation(s)
- Ting Ma
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, 100081, P. R. China
| | - Chen-Xi Wang
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, 100081, P. R. China
| | - Xi-Yuan Ge
- Central Laboratory, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, 100081, P. R. China
| | - Yu Zhang
- Department of Oral Implantology, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, 100081, P. R. China
| |
Collapse
|
13
|
Omidian H, Wilson RL, Babanejad N. Bioinspired Polymers: Transformative Applications in Biomedicine and Regenerative Medicine. Life (Basel) 2023; 13:1673. [PMID: 37629530 PMCID: PMC10456054 DOI: 10.3390/life13081673] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 07/28/2023] [Accepted: 07/28/2023] [Indexed: 08/27/2023] Open
Abstract
Bioinspired polymers have emerged as a promising field in biomaterials research, offering innovative solutions for various applications in biomedical engineering. This manuscript provides an overview of the advancements and potential of bioinspired polymers in tissue engineering, regenerative medicine, and biomedicine. The manuscript discusses their role in enhancing mechanical properties, mimicking the extracellular matrix, incorporating hydrophobic particles for self-healing abilities, and improving stability. Additionally, it explores their applications in antibacterial properties, optical and sensing applications, cancer therapy, and wound healing. The manuscript emphasizes the significance of bioinspired polymers in expanding biomedical applications, addressing healthcare challenges, and improving outcomes. By highlighting these achievements, this manuscript highlights the transformative impact of bioinspired polymers in biomedical engineering and sets the stage for further research and development in the field.
Collapse
Affiliation(s)
- Hossein Omidian
- Barry and Judy Silverman College of Pharmacy, Nova Southeastern University, Fort Lauderdale, FL 33328, USA; (R.L.W.); (N.B.)
| | | | | |
Collapse
|
14
|
Chen T, Jinno Y, Atsuta I, Tsuchiya A, Stocchero M, Bressan E, Ayukawa Y. Current surface modification strategies to improve the binding efficiency of emerging biomaterial polyetheretherketone (PEEK) with bone and soft tissue: A literature review. J Prosthodont Res 2023; 67:337-347. [PMID: 36372438 DOI: 10.2186/jpr.jpr_d_22_00138] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/01/2023]
Abstract
PURPOSE The aim of this study was to review the literature on current surface modification strategies used to improve the binding efficiency of an emerging biological material, polyetheretherketone (PEEK), with bone and soft tissues. STUDY SELECTION This review was based on articles retrieved from PubMed, Google Scholar, Web of Science, and ScienceDirect databases. The main keywords used during the search were "polyetheretherketone (PEEK)," "implant," "surface modification," "biomaterials," "bone," "osseointegration," and "soft tissue." RESULTS The suitability of PEEK surface modification strategies has been critically analyzed and summarized here. Many cell and in vivo experiments in small animals have shown that the use of advanced modification technologies with appropriate surface modification strategies can effectively improve the surface inertness of PEEK, thereby improving its binding efficiency with bone and soft tissues. CONCLUSIONS Surface modifications of PEEK have revealed new possibilities for implant treatment; however, most results are based on in vitro or short-term in vivo evaluations in small animals. To achieve a broad application of PEEK in the field of oral implantology, more in vivo experiments and long-term clinical evaluations are needed to investigate the effects of various surface modifications on the tissue integration ability of PEEK to develop an ideal implant material.
Collapse
Affiliation(s)
- Tianjie Chen
- Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University, Fukuoka, Japan
| | - Yohei Jinno
- Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University, Fukuoka, Japan
| | - Ikiru Atsuta
- Division of Advanced Dental Devices and Therapeutics, Faculty of Dental Science, Kyushu University, Fukuoka, Japan
| | - Akira Tsuchiya
- Department of Biomaterials, Faculty of Dental Science, Kyushu University, Fukuoka, Japan
| | - Michele Stocchero
- Department of Oral and Maxillofacial Surgery and Oral Medicine, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Eriberto Bressan
- Department of Neurosciences, Section of Dentistry, University of Padova, Padova, Italy
| | - Yasunori Ayukawa
- Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University, Fukuoka, Japan
| |
Collapse
|
15
|
Choi SM, Jung HW, Ryu JH, You HK. Effect of polydopamine and fluoride ion coating on dental enamel remineralization: an in vitro study. BMC Oral Health 2023; 23:526. [PMID: 37496034 PMCID: PMC10373225 DOI: 10.1186/s12903-023-03221-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Accepted: 07/11/2023] [Indexed: 07/28/2023] Open
Abstract
BACKGROUND Fluoride treatment is one of the most effective dental caries prevention methods. To continuously prevent dental caries, stably immobilizing the fluoride on the tooth enamel is highly desirable. This study aimed to evaluate the remineralization of tooth enamels by one-pot coating using polydopamine and fluoride ions. METHODS To prepare the enamel specimens for polydopamine- and fluoride ion-coating, they were treated with polydopamine- and fluoride-containing gels. The enamel specimens were collected from human molars in a blind manner (n = 100) and were randomized into five treatment groups (n = 20, each): 1) untreated, 2) polydopamine-coated, 3) fluoride-containing gel-treated, 4) F varnish-treated, and 5) polydopamine- and fluoride ion-coated enamels. Vickers hardness number (VHN), morphology, and fluoride contents of the specimens were measured before and after the pH-cycling regimen. RESULTS Polydopamine- and fluoride ion-coated enamels showed the highest fluoride content and lowest VHN reduction among the samples. The fluoride content of the polydopamine/fluoride ion (PD/F)-coated enamel was increased to 182 ± 6.6%, which was far higher than that of the uncoated enamel (112.3 ± 32.8%, P < 0.05). The changes in the VHN values (ΔVHN) of PD/F-coated enamel substrates showed a slight reduction in the VHN (-3.6%, P < 0.05), which was far lower than that in the control group (-18.9%, P < 0.05). In addition, scanning electron microscopy clearly supported the effect of polydopamine- and fluoride ion-coatings on the remineralization of enamel specimens. CONCLUSION Our findings suggest that one-pot treatments with polydopamine and fluoride ions could significantly enhance remineralization by inhibiting enamel demineralization through the prolonged retention of fluoride ions.
Collapse
Affiliation(s)
- Seok-Min Choi
- Department of Periodontology, Clinical Lab for Innovative Periodontology, School of Dentistry, Wonkwang University, Iksan, Jeonbuk, 54538, South Korea
| | - Hee-Won Jung
- Department of Periodontology, Clinical Lab for Innovative Periodontology, School of Dentistry, Wonkwang University, Iksan, Jeonbuk, 54538, South Korea
| | - Ji Hyun Ryu
- Department of Carbon Convergence Engineering, Wonkwang University, Iksan, Jeonbuk, 54538, South Korea.
- Smart Convergence Materials Analysis Center, Wonkwang University, Iksan, Jeonbuk, 54538, South Korea.
| | - Hyung-Keun You
- Department of Periodontology, Clinical Lab for Innovative Periodontology, School of Dentistry, Wonkwang University, Iksan, Jeonbuk, 54538, South Korea.
| |
Collapse
|
16
|
Wei Z, Zhang Z, Zhu W, Weng X. Polyetheretherketone development in bone tissue engineering and orthopedic surgery. Front Bioeng Biotechnol 2023; 11:1207277. [PMID: 37456732 PMCID: PMC10345210 DOI: 10.3389/fbioe.2023.1207277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 06/16/2023] [Indexed: 07/18/2023] Open
Abstract
Polyetheretherketone (PEEK) has been widely used in the medical field as an implant material, especially in bone tissue engineering and orthopedic surgery, in recent years. This material exhibits superior stability at high temperatures and is biosecured without harmful reactions. However, the chemical and biological inertness of PEEK still limits its applications. Recently, many approaches have been applied to improve its performance, including the modulation of physical morphology, chemical composition and antimicrobial agents, which advanced the osteointegration as well as antibacterial properties of PEEK materials. Based on the evolution of PEEK biomedical devices, many studies on the use of PEEK implants in spine surgery, joint surgery and trauma repair have been performed in the past few years, in most of which PEEK implants show better outcomes than traditional metal implants. This paper summarizes recent studies on the modification and application of biomedical PEEK materials, which provides further research directions for PEEK implants.
Collapse
Affiliation(s)
- Zhanqi Wei
- Department of Orthopedics, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- School of Medicine, Tsinghua University, Beijing, China
| | - Ze Zhang
- Department of Orthopedics, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- School of Medicine, Tsinghua University, Beijing, China
| | - Wei Zhu
- Department of Orthopedics, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Xisheng Weng
- Department of Orthopedics, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Department of State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| |
Collapse
|
17
|
Zeng J, Gu C, Geng X, Lin K, Xie Y, Chen X. Combined photothermal and sonodynamic therapy using a 2D black phosphorus nanosheets loaded coating for efficient bacterial inhibition and bone-implant integration. Biomaterials 2023; 297:122122. [PMID: 37080119 DOI: 10.1016/j.biomaterials.2023.122122] [Citation(s) in RCA: 17] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 03/29/2023] [Accepted: 04/08/2023] [Indexed: 04/22/2023]
Abstract
Surgical site infection (SSI) remains a major threat for implant failure in orthopedics. Herein, we report a dual-functional coating on Ti implants (named Ti/PDA/BP) with the integration of two-dimensional (2D) photo-sono sensitive black phosphorus nanosheets (BPNSs) and polydopamine (PDA) for efficient bacterial inhibition and bone-implant integration. For the first time, we employ BPNSs as generators of reactive radicals (ROS) under ultrasound (US) stimuli for implant associated infection. Additionally, the application of PDA improves the stability of BPNSs, the biocompatibility and photothermal performance of this hybrid coating. The as-prepared Ti/PDA/BP coating exhibits superior biocompatibility, bioactivity, photothermal and sonodynamic conversion abilities. Owing to the synergistic effect of hyperthermia and ·OH, Ti/PDA/BP damages the membrane and antioxidant system of Staphylococcus aureus, reaching a high antibacterial activity of 96.6% in vitro and 97.3% in vivo with rapid 10 min NIR irradiation and 20 min US treatment. In addition, we firstly unveil the significant effect of Ti/PDA/BP-based sonodynamic therapy (SDT) on bacterial membrane and oxidative stress at the transcriptome level. Moreover, the Ti/PDA/BP coating remarkably promotes osteogenesis in vitro and bone-implant osseointegration in vivo. Overall, development of Ti/PDA/BP bioactive coating provides a new strategy for combating the implant associated infection.
Collapse
Affiliation(s)
- Junkai Zeng
- Spine Center, Department of Orthopaedics, Changzheng Hospital, Naval Medical University (Second Military Medical University), Shanghai, PR China
| | - Changjiang Gu
- Spine Center, Department of Orthopaedics, Changzheng Hospital, Naval Medical University (Second Military Medical University), Shanghai, PR China
| | - Xiangwu Geng
- Spine Center, Department of Orthopaedics, Changzheng Hospital, Naval Medical University (Second Military Medical University), Shanghai, PR China
| | - Kaili Lin
- Department of Oral and Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Research Unit of Oral and Maxillofacial Regenerative Medicine, Chinese Academy of Medical Sciences, Shanghai, PR China.
| | - Youzhuan Xie
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China.
| | - Xiongsheng Chen
- Spine Center, Department of Orthopaedics, Changzheng Hospital, Naval Medical University (Second Military Medical University), Shanghai, PR China; Department of Orthopaedics, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China.
| |
Collapse
|
18
|
Wang X, Ma N, Feng L, Shen M, Zhou Y, Zhang X, Huang R, Zhou L, Ji S, Lou Y, Zhu Z. Fabrication of bFGF/polydopamine-loaded PEEK implants for improving soft tissue integration by upregulating Wnt/β-catenin signaling. Heliyon 2023; 9:e14800. [PMID: 37012909 PMCID: PMC10066536 DOI: 10.1016/j.heliyon.2023.e14800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Revised: 03/15/2023] [Accepted: 03/17/2023] [Indexed: 03/28/2023] Open
Abstract
The difficulties associated with polyetheretherketone (PEEK) implants and soft tissue integration for craniomaxillofacial bone repair have led to a series of complications that limit the clinical benefits. In this study, 3D printed multi-stage microporous PEEK implants coated with bFGF via polydopamine were fabricated to enhance PEEK implant-soft tissue integration. Multistage microporous PEEK scaffolds prepared by sulfonation of concentrated sulfuric acid were coated with polydopamine, and then used as templates for electrophoretic deposition of bFGF bioactive factors. Achieving polydopamine and bFGF sustained release, the composite PEEK scaffolds possessed good mechanical properties, hydrophilicity, protein adhesion properties. The in vitro results indicated that bFGF/polydopamine-loaded PEEK exhibited good biocompatibility to rabbit embryonic fibroblasts (REF) by promoting cell proliferation, adhesion, and migration. Ribonucleic acid sequencing (RNA-seq) revealed that bFGF/polydopamine-loaded PEEK implants significantly upregulated the expression of genes and proteins associated with soft tissue integration and activated Wnt/β-catenin signaling in biological processes, but related expression of genes and proteins was significantly downregulated when the Wnt/β-catenin signaling was inhibited. Furthermore, in vivo bFGF/polydopamine-loaded PEEK implants exhibited excellent performance in improving the growth and adhesion of the surrounding soft tissue. In summary, bFGF/polydopamine-loaded PEEK implants possess soft tissue integration properties by activating the Wnt/β-catenin signaling, which have a potential translational clinical application in the future.
Collapse
|
19
|
Dixon DT, Gomillion CT. 3D-Printed conductive polymeric scaffolds with direct current electrical stimulation for enhanced bone regeneration. J Biomed Mater Res B Appl Biomater 2023; 111:1351-1364. [PMID: 36825765 DOI: 10.1002/jbm.b.35239] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 12/13/2022] [Accepted: 02/10/2023] [Indexed: 02/25/2023]
Abstract
Various methods have been used to treat bone defects caused by genetic disorders, injury, or disease. Yet, there is still great need to develop alternative approaches to repair damaged bone tissue. Bones naturally exhibit piezoelectric potential, or the ability to convert mechanical stresses into electrical impulses. This phenomenon has been utilized clinically to enhance bone regeneration in conjunction with electrical stimulation (ES) therapies; however, oftentimes with critical-sized bone defects, the bioelectric potential at the site of injury is compromised, resulting in less desirable outcomes. In the present study, the potential of a 3D-printed conductive polymer blend to enhance bone formation through restoration of the bioelectrical microenvironment was evaluated. A commercially available 3D printer was used to create circular, thin-film scaffolds consisting of either polylactide (PLA) or a conductive PLA (CPLA) composite. Preosteoblast cells were seeded onto the scaffolds and subjected to direct current ES via a purpose-built cell culture chamber. It was found that CPLA scaffolds had no adverse effects on cell viability, proliferation or differentiation when compared with control scaffolds. The addition of ES, however, resulted in a significant increase in the expression of osteocalcin, a protein indicative of osteoblast maturation, after 14 days of culture. Furthermore, xylenol orange staining also showed the presence of increased mineralized calcium nodules in cultures undergoing stimulation. This study demonstrates the potential for low-cost, conductive scaffolding materials to support cell viability and enhance in vitro mineralization in conjunction with ES.
Collapse
Affiliation(s)
- Damion T Dixon
- School of Environmental, Civil, Agricultural and Mechanical Engineering, College of Engineering, University of Georgia, Athens, Georgia, USA
| | - Cheryl T Gomillion
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia, USA
| |
Collapse
|
20
|
Mahnavi A, Shahriari-Khalaji M, Hosseinpour B, Ahangarian M, Aidun A, Bungau S, Hassan SSU. Evaluation of cell adhesion and osteoconductivity in bone substitutes modified by polydopamine. Front Bioeng Biotechnol 2023; 10:1057699. [PMID: 36727042 PMCID: PMC9885973 DOI: 10.3389/fbioe.2022.1057699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 12/30/2022] [Indexed: 01/15/2023] Open
Abstract
Bones damaged due to disease or accidents can be repaired in different ways. Tissue engineering has helped with scaffolds made of different biomaterials and various methods. Although all kinds of biomaterials can be useful, sometimes their weakness in cellular activity or osteoconductivity prevents their optimal use in the fabrication of bone scaffolds. To solve this problem, we need additional processes, such as surface modification. One of the common methods is coating with polydopamine. Polydopamine can not only cover the weakness of the scaffolds in terms of cellular properties, but it can also create or increase osteoconductivity properties. Polydopamine creates a hydrophilic layer on the surface of scaffolds due to a large number of functional groups such as amino and hydroxyl groups. This layer allows bone cells to anchor and adheres well to the surfaces. In addition, it creates a biocompatible environment for proliferation and differentiation. Besides, the polydopamine coating makes the surfaces chemically active by catechol and amine group, and as a result of their presence, osteoconductivity increases. In this mini-review, we investigated the characteristics, structure, and properties of polydopamine as a modifier of bone substitutes. Finally, we evaluated the cell adhesion and osteoconductivity of different polydopamine-modified bone scaffolds.
Collapse
Affiliation(s)
- Ali Mahnavi
- Department of Biomaterials, Faculty of Interdisciplinary Science and Technology, Tarbiat Modares University, Tehran, Iran
| | - Mina Shahriari-Khalaji
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, China
| | | | - Mostafa Ahangarian
- Department of Biomaterials, Faculty of Interdisciplinary Science and Technology, Tarbiat Modares University, Tehran, Iran
| | - Amir Aidun
- National Cell Bank of Iran, Pasteur Institute of Iran, Tehran, Iran,Tissues and Biomaterials Research Group (TBRG), Universal Scientific Education and Research Network (USERN), Tehran, Iran,*Correspondence: Amir Aidun, ; Simona Bungau, ; Syed Shams ul Hassan,
| | - Simona Bungau
- Department of Pharmacy, Faculty of Medicine and Pharmacy, University of Oradea, Oradea, Romania,*Correspondence: Amir Aidun, ; Simona Bungau, ; Syed Shams ul Hassan,
| | - Syed Shams ul Hassan
- Shanghai Key Laboratory for Molecular Engineering of Chiral Drugs, School of Pharmacy, Shanghai Jiao Tong University, Shanghai, China,Department of Natural Product Chemistry, School of Pharmacy, Shanghai Jiao Tong University, Shanghai, China,*Correspondence: Amir Aidun, ; Simona Bungau, ; Syed Shams ul Hassan,
| |
Collapse
|
21
|
Casagualda C, Mancebo-Aracil J, Moreno-Villaécija M, López-Moral A, Alibés R, Busqué F, Ruiz-Molina D. Mussel-Inspired Lego Approach for Controlling the Wettability of Surfaces with Colorless Coatings. Biomimetics (Basel) 2022; 8:3. [PMID: 36648789 PMCID: PMC9844497 DOI: 10.3390/biomimetics8010003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 12/14/2022] [Accepted: 12/14/2022] [Indexed: 12/24/2022] Open
Abstract
The control of surface wettability with polyphenol coatings has been at the forefront of materials research since the late 1990s, when robust underwater adhesion was linked to the presence of L-DOPA-a catecholic amino acid-in unusually high amounts, in the sequences of several mussel foot proteins. Since then, several successful approaches have been reported, although a common undesired feature of most of them is the presence of a remnant color and/or the intrinsic difficulty in fine-tuning and controlling the hydrophobic character. We report here a new family of functional catechol-based coatings, grounded in the oxidative condensation of readily available pyrocatechol and thiol-capped functional moieties. The presence of at least two additional thiol groups in their structure allows for polymerization through the formation of disulfide bonds. The synthetic flexibility, together with its modular character, allowed us to: (I) develop coatings with applications exemplified by textiles for oil-spill water treatment; (II) develop multifunctional coatings, and (III) fine-tune the WCA for flat and textile surfaces. All of this was achieved with the application of colorless coatings.
Collapse
Affiliation(s)
- Carolina Casagualda
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain
- Departament de Química, Universitat Autònoma de Barcelona, Bellaterra, 08193 Barcelona, Spain
| | - Juan Mancebo-Aracil
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain
- Instituto de Química del Sur-INQUISUR (UNS-CONICET), Universidad Nacional del Sur, Bahía Blanca 8000, Argentina
| | - Miguel Moreno-Villaécija
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain
| | - Alba López-Moral
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain
- Departament de Química, Universitat Autònoma de Barcelona, Bellaterra, 08193 Barcelona, Spain
| | - Ramon Alibés
- Departament de Química, Universitat Autònoma de Barcelona, Bellaterra, 08193 Barcelona, Spain
| | - Félix Busqué
- Departament de Química, Universitat Autònoma de Barcelona, Bellaterra, 08193 Barcelona, Spain
| | - Daniel Ruiz-Molina
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain
| |
Collapse
|
22
|
Sekar S, Lee S. In Situ Facile Synthesis of Low-Cost Biogenic Eggshell-Derived Nanohydroxyapatite/Chitosan Biocomposites for Orthopedic Implant Applications. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:4302. [PMID: 36500924 PMCID: PMC9739235 DOI: 10.3390/nano12234302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 11/25/2022] [Accepted: 11/29/2022] [Indexed: 06/17/2023]
Abstract
In situ facile synthesis and the characterization of nanohydroxyapatite/chitosan (nHAP/CS) biocomposites were investigated for examining their potential applications in orthopedic implant technology. Firstly, the bare nHAP, europium-doped hydroxyapatite (Eu-nHAP), yttrium-doped hydroxyapatite (Y-nHAP), and Eu- and Y-codoped hydroxyapatite (Eu,Y-nHAP) nanoparticles were synthesized by the wet precipitation technique using biowaste-eggshell-derived calcium oxide powders. Then, through ultrasonication using the nanohydroxyapatite/chitosan mixtures (molar ratio = 1:2), the nHAP/CS, Eu-nHAP/CS, Y-nHAP/CS, and Eu,Y-nHAP/CS biocomposites were fabricated. Among them, Eu,Y-nHAP/CS showed higher cell viability (94.9%), higher solubility (pH = 7.6 after 21 days), and greater antibacterial activity than those of the other composites. In addition, Eu,Y-nHAP/CS exhibited improved mechanical properties compared with the other composites. For example, the nanoindentation test displayed the Eu,Y-nHAP/CS-coated 316L stainless steel implant to possess a higher Young's modulus value (9.24 GPa) and greater hardness value (300.71 MPa) than those of the others. The results indicate that the biomass-eggshell-derived Eu,Y-doped nHAP is of good use for orthopedic implant applications.
Collapse
Affiliation(s)
- Sankar Sekar
- Department of Semiconductor Science, Dongguk University-Seoul, Seoul 04620, Republic of Korea
- Quantum-Functional Semiconductor Research Center, Dongguk University-Seoul, Seoul 04620, Republic of Korea
| | - Sejoon Lee
- Department of Semiconductor Science, Dongguk University-Seoul, Seoul 04620, Republic of Korea
- Quantum-Functional Semiconductor Research Center, Dongguk University-Seoul, Seoul 04620, Republic of Korea
| |
Collapse
|
23
|
Jing X, Xiong Z, Lin Z, Sun T. The Application of Black Phosphorus Nanomaterials in Bone Tissue Engineering. Pharmaceutics 2022; 14:pharmaceutics14122634. [PMID: 36559127 PMCID: PMC9787998 DOI: 10.3390/pharmaceutics14122634] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 11/22/2022] [Accepted: 11/24/2022] [Indexed: 11/30/2022] Open
Abstract
Recently, research on and the application of nanomaterials such as graphene, carbon nanotubes, and metal-organic frameworks has become increasingly popular in tissue engineering. In 2014, a two-dimensional sheet of black phosphorus (BP) was isolated from massive BP crystals. Since then, BP has attracted significant attention as an emerging nanomaterial. BP possesses many advantages such as light responsiveness, electrical conductivity, degradability, and good biocompatibility. Thus, it has broad prospects in biomedical applications. Moreover, BP is composed of phosphorus, which is a key bone tissue component with good biocompatibility and osteogenic repair ability. Thereby, BP exhibits excellent advantages for application in bone tissue engineering. In this review, the structure and the physical and chemical properties of BP are described. In addition, the current applications of BP in bone tissue engineering are reviewed to aid the future research and application of BP.
Collapse
Affiliation(s)
- Xirui Jing
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Zekang Xiong
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Zian Lin
- Hubei Key Laboratory of Bioinorganic Chemistry and Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Tingfang Sun
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Correspondence:
| |
Collapse
|
24
|
He F, Li J, Wang Y, Li Z, Wang L, Li Y, Chen H, Wang C, Liu B, Ma P, Dong G, Zhou P. Design of Cefotaxime Sodium-Loaded Polydopamine Coatings with Controlled Surface Roughness for Titanium Implants. ACS Biomater Sci Eng 2022; 8:4751-4763. [PMID: 36191062 DOI: 10.1021/acsbiomaterials.2c00702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The success rate of dental implants is limited by peri-implant infection and insufficient osseointegration. Therefore, reducing the occurrence of peri-implantitis and promoting osseointegration are in demand. A roughened surface has commonly been applied to improve the osseointegration of implants, but it will accelerate the attachment of bacteria. We have developed novel antibiotic-decorated titanium (Ti) surfaces by the immobilization of dopamine and cefotaxime sodium (CS) simultaneously. Moreover, the surface roughness of the polydopamine (PDA)/CS coating was controlled by the changes in polymerization times as determined by atomic force microscopy. Then, all antibiotic-grafted Ti surfaces could effectively prevent the adhesion and proliferation of both Escherichia coli and Streptococcus mutans in comparison to the pristine control. For the culture and osteogenic differentiation of human umbilical mesenchymal stem cells (hUMSCs) on the substrate surface, PDA/CS coating with polymerization times less than 30 min showed acceptable biocompatibility, but the upregulation of marker genes and proteins was detected when the polymerization time was more than 30 min. Moreover, the best calcium deposition results were found in the 30 min PDA/CS group with or without the addition of osteogenic factors. Therefore, our PDA/CS coating with a polymerization time of 30 min holds great potential to design dental implants with dual bacteriostatic and osteogenic properties.
Collapse
Affiliation(s)
- Fei He
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China.,Key Laboratory of Mechanics on Disaster and Environment in Western China, Ministry of Education, College of Civil Engineering and Mechanics, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Jing Li
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Yixi Wang
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Zhipeng Li
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Lu Wang
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Yuchen Li
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Huiling Chen
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Chenggang Wang
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Bin Liu
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Peng Ma
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Genxi Dong
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Ping Zhou
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China.,Department of Orthopedics, Lanzhou University Second Hospital, No. 82 Cuiyingmen Street, Lanzhou 730030, Gansu, P. R. China
| |
Collapse
|
25
|
Yan L, Zhou T, Ni R, Jia Z, Jiang Y, Guo T, Wang K, Chen X, Han L, Lu X. Adhesive Gelatin-Catechol Complex Reinforced Poly(Acrylic Acid) Hydrogel with Enhanced Toughness and Cell Affinity for Cartilage Regeneration. ACS APPLIED BIO MATERIALS 2022; 5:4366-4377. [PMID: 36044775 DOI: 10.1021/acsabm.2c00533] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The repair of cartilage damage caused by trauma, wear, or degenerative deformation remains a major challenge in modern medicine. Therefore, it is essential to develop a mechanically compatible and bioactive scaffold for cartilage tissue regeneration. In this study, a mussel-inspired, tough, adhesive polydopamine/gelatin-poly(acrylic acid) (PDA/Gel-PAA) composite hydrogel was developed for cartilage regeneration. The hydrogel achieved a high compressive strength of up to 0.67 MPa and a toughness of 420 J/m2 because of the unique chemical-physical cross-linking structure by introducing the PDA/Gel complex into the PAA network. PAA chains with rich carboxyl groups mimic the negatively charged glycosaminoglycans (GAGs) in the natural cartilage extracellular matrix (ECM), leading to strong water retention in the hydrogel. The incorporation of the PDA/Gel complex with catechol groups on PDA and arginine-glycine-aspartic acid (RGD) sequences on gelatin chains provided abundant adhesive motifs to improve the cell affinity and tissue adhesiveness of PAA, thereby facilitating the adhesion and proliferation of bone marrow stromal cells (BMSCs). In addition, transforming growth factor-β3 (TGFβ3) was stably immobilized and released from the PDA/Gel-PAA hydrogel. Thus, adhesive hydrogels can provide a suitable microenvironment to promote cell migration in the defect area and induce chronogenesis for cartilage regeneration.
Collapse
Affiliation(s)
- Liwei Yan
- School of Materials Science and Engineering, Key Lab of Advanced Technologies of Materials, Ministry of Education, Yibin Institute of Southwest Jiaotong University, Southwest Jiaotong University, Chengdu 610031, Sichuan, China
| | - Ting Zhou
- School of Materials Science and Engineering, Key Lab of Advanced Technologies of Materials, Ministry of Education, Yibin Institute of Southwest Jiaotong University, Southwest Jiaotong University, Chengdu 610031, Sichuan, China
| | - Ruicheng Ni
- School of Materials Science and Engineering, Key Lab of Advanced Technologies of Materials, Ministry of Education, Yibin Institute of Southwest Jiaotong University, Southwest Jiaotong University, Chengdu 610031, Sichuan, China
| | - Zhanrong Jia
- School of Materials Science and Engineering, Key Lab of Advanced Technologies of Materials, Ministry of Education, Yibin Institute of Southwest Jiaotong University, Southwest Jiaotong University, Chengdu 610031, Sichuan, China
| | - Yanan Jiang
- School of Materials Science and Engineering, Key Lab of Advanced Technologies of Materials, Ministry of Education, Yibin Institute of Southwest Jiaotong University, Southwest Jiaotong University, Chengdu 610031, Sichuan, China
| | - Tailin Guo
- College of Medicine, Southwest Jiaotong University, Chengdu 610031, Sichuan, China
| | - Kefeng Wang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, Sichuan, China
| | - Xian Chen
- Hospital of Chengdu University of Traditional Chinese Medicine, Chengdu 610072, Sichuan, China
| | - Lu Han
- School of Medicine and Pharmaceutics, Laboratory for Marine Drugs and Bioproducts, Pilot National Laboratory for Marine Science and Technology, Ocean University of China, Qingdao 266003, Shandong, China
| | - Xiong Lu
- School of Materials Science and Engineering, Key Lab of Advanced Technologies of Materials, Ministry of Education, Yibin Institute of Southwest Jiaotong University, Southwest Jiaotong University, Chengdu 610031, Sichuan, China
| |
Collapse
|
26
|
Taghizadeh A, Taghizadeh M, Khodadadi Yazdi M, Zarrintaj P, Ramsey JD, Seidi F, Stadler FJ, Lee H, Saeb MR, Mozafari M. Mussel‐Inspired
Biomaterials: From Chemistry to Clinic. Bioeng Transl Med 2022; 7:e10385. [PMID: 36176595 PMCID: PMC9472010 DOI: 10.1002/btm2.10385] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 05/25/2022] [Accepted: 07/16/2022] [Indexed: 11/18/2022] Open
Abstract
After several billions of years, nature still makes decisions on its own to identify, develop, and direct the most effective material for phenomena/challenges faced. Likewise, and inspired by the nature, we learned how to take steps in developing new technologies and materials innovations. Wet and strong adhesion by Mytilidae mussels (among which Mytilus edulis—blue mussel and Mytilus californianus—California mussel are the most well‐known species) has been an inspiration in developing advanced adhesives for the moist condition. The wet adhesion phenomenon is significant in designing tissue adhesives and surgical sealants. However, a deep understanding of engaged chemical moieties, microenvironmental conditions of secreted proteins, and other contributing mechanisms for outstanding wet adhesion mussels are essential for the optimal design of wet glues. In this review, all aspects of wet adhesion of Mytilidae mussels, as well as different strategies needed for designing and fabricating wet adhesives are discussed from a chemistry point of view. Developed muscle‐inspired chemistry is a versatile technique when designing not only wet adhesive, but also, in several more applications, especially in the bioengineering area. The applications of muscle‐inspired biomaterials in various medical applications are summarized for future developments in the field.
Collapse
Affiliation(s)
- Ali Taghizadeh
- Institute of Tissue Regeneration Engineering (ITREN) Dankook University Cheonan Republic of Korea
| | - Mohsen Taghizadeh
- Institute of Tissue Regeneration Engineering (ITREN) Dankook University Cheonan Republic of Korea
| | - Mohsen Khodadadi Yazdi
- Center of Excellence in Electrochemistry, School of Chemistry, College of Science University of Tehran Tehran Iran
| | - Payam Zarrintaj
- School of Chemical Engineering, Oklahoma State University 420 Engineering North Stillwater OK United States
| | - Joshua D. Ramsey
- School of Chemical Engineering, Oklahoma State University 420 Engineering North Stillwater OK United States
| | - Farzad Seidi
- Jiangsu Co‐Innovation Center of Efficient Processing and Utilization of Forest Resources and International Innovation Center for Forest Chemicals and Materials Nanjing Forestry University Nanjing China
| | - Florian J. Stadler
- College of Materials Science and Engineering, Shenzhen Key Laboratory of Polymer Science and Technology Guangdong China
| | - Haeshin Lee
- Department of Chemistry Korea Advanced Institute of Science and Technology (KAIST) Daejeon Republic of Korea
| | - Mohammad Reza Saeb
- Department of Polymer Technology, Faculty of Chemistry Gdańsk University of Technology, G. Narutowicza 11 Gdańsk Poland
| | - Masoud Mozafari
- Department of Tissue Engineering & Regenerative Medicine Iran University of Medical Sciences Tehran Iran
| |
Collapse
|
27
|
Du J, Zhou Y, Bao X, Kang Z, Huang J, Xu G, Yi C, Li D. Surface polydopamine modification of bone defect repair materials: Characteristics and applications. Front Bioeng Biotechnol 2022; 10:974533. [PMID: 35935489 PMCID: PMC9355039 DOI: 10.3389/fbioe.2022.974533] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Accepted: 07/04/2022] [Indexed: 12/02/2022] Open
Abstract
Bone defects are a common challenge for clinical orthopedic surgeons. The existing bone defect repair materials are difficult to achieve satisfactory osseointegration between the material and the bone. Therefore, it is increasingly important to find effective methods to improve the integration of the materials with the bone and thus facilitate bone defect repair. Researchers have found that polydopamine (PDA) has a structure and properties similar to the adhesive proteins secreted by mussels in nature, with good biocompatibility, bioactivity, hydrophilicity, bio-adhesion and thermal stability. PDA is therefore expected to be used as a surface modification material for bone repair materials to improve the bonding of bone repair materials to the bone surface. This paper reviews research related to PDA-modified bone repair materials and looks at their future applications.
Collapse
Affiliation(s)
- Jianhang Du
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Ying Zhou
- Department of Rehabilitation, General Hospital of Chinese People’s Liberation Army, Beijing, China
| | - Xiaogang Bao
- Spine Center, Department of Orthopedics Surgery, Changzheng Hospital, Second Military Medical University, Shanghai, China
| | - Zhanrong Kang
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Jianming Huang
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Guohua Xu
- Spine Center, Department of Orthopedics Surgery, Changzheng Hospital, Second Military Medical University, Shanghai, China
- *Correspondence: Guohua Xu, ; Chengqing Yi, ; Dejian Li,
| | - Chengqing Yi
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
- *Correspondence: Guohua Xu, ; Chengqing Yi, ; Dejian Li,
| | - Dejian Li
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
- *Correspondence: Guohua Xu, ; Chengqing Yi, ; Dejian Li,
| |
Collapse
|
28
|
Fabrication of a Cell-Friendly Poly(dimethylsiloxane) Culture Surface via Polydopamine Coating. MICROMACHINES 2022; 13:mi13071122. [PMID: 35888939 PMCID: PMC9315764 DOI: 10.3390/mi13071122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 06/24/2022] [Accepted: 07/12/2022] [Indexed: 02/04/2023]
Abstract
In this study, we fabricated a poly(dimethylsiloxane) (PDMS) surface coated with polydopamine (PDA) to enhance cell adhesion. PDA is well known for improving surface adhesion on various surfaces due to the abundant reactions enabled by the phenyl, amine, and catechol groups contained within it. To confirm the successful surface coating with PDA, the water contact angle and X-ray photoelectron spectroscopy were analyzed. Human umbilical vein endothelial cells (HUVECs) and human-bone-marrow-derived mesenchymal stem cells (MSCs) were cultured on the PDA-coated PDMS surface to evaluate potential improvements in cell adhesion and proliferation. HUVECs were also cultured inside a cylindrical PDMS microchannel, which was constructed to mimic a human blood vessel, and their growth and performance were compared to those of cells grown inside a rectangular microchannel. This study provides a helpful perspective for building a platform that mimics in vivo environments in a more realistic manner.
Collapse
|
29
|
Wu H, Zhao C, Lin K, Wang X. Mussel-Inspired Polydopamine-Based Multilayered Coatings for Enhanced Bone Formation. Front Bioeng Biotechnol 2022; 10:952500. [PMID: 35875492 PMCID: PMC9301208 DOI: 10.3389/fbioe.2022.952500] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Accepted: 06/17/2022] [Indexed: 12/03/2022] Open
Abstract
Repairing bone defects remains a challenge in clinical practice and the application of artificial scaffolds can enhance local bone formation, but the function of unmodified scaffolds is limited. Considering different application scenarios, the scaffolds should be multifunctionalized to meet specific demands. Inspired by the superior adhesive property of mussels, polydopamine (PDA) has attracted extensive attention due to its universal capacity to assemble on all biomaterials and promote further adsorption of multiple external components to form PDA-based multilayered coatings with multifunctional property, which can induce synergistic enhancement of new bone formation, such as immunomodulation, angiogenesis, antibiosis and antitumor property. This review will summarize mussel-inspired PDA-based multilayered coatings for enhanced bone formation, including formation mechanism and biofunction of PDA coating, as well as different functional components. The synergistic enhancement of multiple functions for better bone formation will also be discussed. This review will inspire the design and fabrication of PDA-based multilayered coatings for different application scenarios and promote deeper understanding of their effect on bone formation, but more efforts should be made to achieve clinical translation. On this basis, we present a critical conclusion, and forecast the prospects of PDA-based multilayered coatings for bone regeneration.
Collapse
Affiliation(s)
| | | | - Kaili Lin
- *Correspondence: Kaili Lin, ; Xudong Wang,
| | | |
Collapse
|
30
|
Application of biomolecules modification strategies on PEEK and its composites for osteogenesis and antibacterial properties. Colloids Surf B Biointerfaces 2022; 215:112492. [PMID: 35430485 DOI: 10.1016/j.colsurfb.2022.112492] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 03/24/2022] [Accepted: 04/04/2022] [Indexed: 12/24/2022]
Abstract
As orthopedic and dental implants, polyetheretherketone (PEEK) is expected to be a common substitute material of titanium (Ti) and its alloys due to its good biocompatibility, chemical stability, and elastic modulus close to that of bone tissue. It could avoid metal allergy and bone resorption caused by the stress shielding effect of Ti implants, widely studied in the medical field. However, the lack of biological activity is not conducive to the clinical application of PEEK implants. Therefore, the surface modification of PEEK has increasingly become one of the research hotspots. Researchers have explored various biomolecules modification methods to effectively enhance the osteogenic and antibacterial activities of PEEK and its composites. Therefore, this review mainly summarizes the recent research of PEEK modified by biomolecules and discusses the further research directions to promote the clinical transformation of PEEK implants.
Collapse
|
31
|
Deng Y, Shi J, Chan YK, Bai D, Shu R, Shi X, Li Y, Li L, Yang X, Yang W. Heterostructured Metal-Organic Frameworks/Polydopamine Coating Endows Polyetheretherketone Implants with Multimodal Osteogenicity and Photoswitchable Disinfection. Adv Healthc Mater 2022; 11:e2200641. [PMID: 35521819 DOI: 10.1002/adhm.202200641] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 04/12/2022] [Indexed: 02/05/2023]
Abstract
Clinically, bacteria-induced contagion and insufficient osseointegrative property inevitably elicit the failure of orthopedic implants. Herein, a heterostructured coating consisting of simvastatin (SIM)-laden metal-organic frameworks and polydopamine nanolayers is created on a porous bioinert polyetheretherketone implant. The heterostructured coating significantly promotes cytocompatibility and osteogenic differentiation through multimodal osteogenicity mechanisms of zinc ion (Zn2+ ) therapy, SIM drug therapy, and surface micro-/nano-topological stimulation. Under the illumination of near-infrared (NIR) light, singlet oxygen (1 O2 ) and local hyperthermia are produced; besides, NIR light dramatically accelerates the release of Zn2+ ions from heterostructured coatings. Gram-positive and -negative bacteria are effectively eradicated by the synergy of photothermal/photodynamic effects and photo-induced accelerated delivery of Zn2+ ions. The superior osteogenicity and osseointegration, as well as photoswitchable disinfection controlled by NIR light are corroborated via in vivo results. This work highlights the great potential of photoresponsive heterostructured orthopedic implants in treatment of the noninvasive bone reconstruction of bacteria-associated infectious tissues through multimodal phototherapy and photoswitchable ion-therapy.
Collapse
Affiliation(s)
- Yi Deng
- College of Biomedical Engineering School of Chemical Engineering Sichuan University Chengdu 610065 China
- State Key Laboratory of Polymer Materials Engineering Sichuan University Chengdu 610065 China
- Department of Mechanical Engineering The University of Hong Kong Hong Kong 999077 China
| | - Jiacheng Shi
- College of Biomedical Engineering School of Chemical Engineering Sichuan University Chengdu 610065 China
| | - Yau Kei Chan
- Department of Ophthalmology The University of Hong Kong Hong Kong 999077 China
| | - Ding Bai
- State Key Laboratory of Oral Diseases National Clinical Research Center for Oral Disease Department of Orthodontics and Pediatrics West China Hospital of Stomatology Sichuan University Chengdu 610064 China
| | - Rui Shu
- State Key Laboratory of Oral Diseases National Clinical Research Center for Oral Disease Department of Orthodontics and Pediatrics West China Hospital of Stomatology Sichuan University Chengdu 610064 China
| | - Xiuyuan Shi
- Department of Materials Imperial College London London SW7 2AZ UK
| | - Yunfei Li
- Department of Biomedical Engineering The City College of City University of New York New York NY 10031 USA
| | - Limei Li
- Science and Technology Achievement Incubation Center Kunming Medical University Kunming 650500 China
| | - Xiao Yang
- National Engineering Research Center for Biomaterials College of Biomedical Engineering Sichuan University Chengdu 610064 China
| | - Weizhong Yang
- College of Biomedical Engineering School of Chemical Engineering Sichuan University Chengdu 610065 China
| |
Collapse
|
32
|
Negrescu AM, Mitran V, Draghicescu W, Popescu S, Pirvu C, Ionascu I, Soare T, Uzun S, Croitoru SM, Cimpean A. TiO2 Nanotubes Functionalized with Icariin for an Attenuated In Vitro Immune Response and Improved In Vivo Osseointegration. J Funct Biomater 2022; 13:jfb13020043. [PMID: 35466225 PMCID: PMC9036299 DOI: 10.3390/jfb13020043] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/07/2022] [Accepted: 04/11/2022] [Indexed: 12/30/2022] Open
Abstract
Due to their superior mechanical and chemical properties, titanium (Ti) and its alloys have been widely used as orthopedic implantable devices. However, their bioinertness represents a limitation, which can be overcome by employing various surface modifications, such as TiO2 nanotube (TNT) fabrication via electrochemical anodization. Anodic TNTs present tunable dimensions and unique structures, turning them into feasible drug delivery platforms. In the present work, TNTs were loaded with icariin (Ica) through an adhesive intermediate layer of polydopamine (DP), and their in vitro and in vivo biological performance was evaluated. The successful fabrication of the modified surfaces was verified by scanning electron microscopy (SEM), atomic force microscopy (AFM), Fourier transform infrared spectroscopy (FTIR), and contact angle measurements (CA), while the in vitro release of Ica was evaluated via UV-VIS spectrophotometry. In terms of in vitro behaviour, comparative studies on RAW 264.7 macrophages demonstrated that the TNT substrates, especially TNT-DP-Ica, elicited a lower inflammatory response compared to the Ti support. Moreover, the in vivo implantation studies evinced generation of a reduced fibrotic capsule around this implant and increased thickness of the newly formed bone tissue at 1 month and 3 months post-implantation, respectively. Overall, our results indicate that the controlled release of Ica from TNT surfaces could result in an improved osseointegration process.
Collapse
Affiliation(s)
- Andreea-Mariana Negrescu
- Department of Biochemistry and Molecular Biology, Faculty of Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095 Bucharest, Romania; (A.-M.N.); (V.M.)
| | - Valentina Mitran
- Department of Biochemistry and Molecular Biology, Faculty of Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095 Bucharest, Romania; (A.-M.N.); (V.M.)
| | - Wanda Draghicescu
- Faculty of Chemical Engineering and Biotechnology, University Politehnica of Bucharest, 1-7 Polizu, 011061 Bucharest, Romania; (W.D.); (S.P.); (C.P.)
| | - Simona Popescu
- Faculty of Chemical Engineering and Biotechnology, University Politehnica of Bucharest, 1-7 Polizu, 011061 Bucharest, Romania; (W.D.); (S.P.); (C.P.)
| | - Cristian Pirvu
- Faculty of Chemical Engineering and Biotechnology, University Politehnica of Bucharest, 1-7 Polizu, 011061 Bucharest, Romania; (W.D.); (S.P.); (C.P.)
- Faculty of Medical Engineering, University Politehnica of Bucharest, 1-7 Polizu, 011061 Bucharest, Romania
| | - Iuliana Ionascu
- Faculty of Veterinary Medicine, University of Agricultural Sciences and Veterinary Medicine, 105 Spl. Independentei, 050097 Bucharest, Romania; (I.I.); (T.S.); (S.U.)
| | - Teodoru Soare
- Faculty of Veterinary Medicine, University of Agricultural Sciences and Veterinary Medicine, 105 Spl. Independentei, 050097 Bucharest, Romania; (I.I.); (T.S.); (S.U.)
| | - Seralp Uzun
- Faculty of Veterinary Medicine, University of Agricultural Sciences and Veterinary Medicine, 105 Spl. Independentei, 050097 Bucharest, Romania; (I.I.); (T.S.); (S.U.)
| | - Sorin Mihai Croitoru
- Machines and Manufacturing Systems Department, University Politehnica of Bucharest, 313 Spl. Independentei, 060042 Bucharest, Romania;
| | - Anisoara Cimpean
- Department of Biochemistry and Molecular Biology, Faculty of Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095 Bucharest, Romania; (A.-M.N.); (V.M.)
- Correspondence: ; Tel.: +40-21-318-1575 (ext. 106)
| |
Collapse
|
33
|
Zhao Y, Wang Z, Zhao J, Hussain M, Wang M. Additive Manufacturing in Orthopedics: A Review. ACS Biomater Sci Eng 2022; 8:1367-1380. [PMID: 35266709 DOI: 10.1021/acsbiomaterials.1c01072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Additive manufacturing is an advanced manufacturing manner that seems like the industrial revolution. It has the inborn benefit of producing complex formations, which are distinct from traditional machining technology. Its manufacturing strategy is flexible, including a wide range of materials, and its manufacturing cycle is short. Additive manufacturing techniques are progressively used in bone research and orthopedic operation as more innovative materials are developed. This Review lists the recent research results, analyzes the strengths and weaknesses of diverse three-dimensional printing strategies in orthopedics, and sums up the use of varying 3D printing strategies in surgical guides, surgical implants, surgical predictive models, and bone tissue engineering. Moreover, various postprocessing methods for additive manufacturing for orthopedics are described.
Collapse
Affiliation(s)
- Yingchao Zhao
- Xiangya School of Medicine, Central South University, No.172 Yinpenling Street, Tongzipo Road, Changsha 410013, China
| | - Zhen Wang
- Xiangya School of Medicine, Central South University, No.172 Yinpenling Street, Tongzipo Road, Changsha 410013, China
| | - Jingzhou Zhao
- Department of Chemical & Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, Singapore 117585, Singapore
| | - Mubashir Hussain
- Postdoctoral Innovation Practice, Shenzhen Polytechnic, No.4089 Shahe West Road, Xinwei Nanshan District, Shenzhen 518055, China
| | - Maonan Wang
- Department of Chemical & Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, Singapore 117585, Singapore
| |
Collapse
|
34
|
Huang B, Chen M, Tian J, Zhang Y, Dai Z, Li J, Zhang W. Oxygen-Carrying and Antibacterial Fluorinated Nano-Hydroxyapatite Incorporated Hydrogels for Enhanced Bone Regeneration. Adv Healthc Mater 2022; 11:e2102540. [PMID: 35166460 DOI: 10.1002/adhm.202102540] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 01/27/2022] [Indexed: 12/27/2022]
Abstract
Insufficient oxygen availability in tissue engineering is one of the major factors for the failure of clinical transplantation. One potential strategy to conquer this limitation is the fabrication of spontaneous and continuous oxygen supplying scaffolds for in situ tissue regeneration. In this work, a versatile fluorine-incorporating hydrogel is designed which can not only timely and continuously supply oxygen for mesenchymal stem cells (MSCs) to overcome deficient oxygen before vascularization in scaffolds, but can present a higher antibacterial capability to avoid bacterial infections. The HAp@PDA-F nanoparticles are first prepared and then incorporated with the quaternized and methacrylated chitosan forming CS/HAp@PDA-F by photo-crosslinking. In vitro results indicate that CS/HAp@PDA-F hydrogel has outstanding mechanical performance, moreover, it also has the oxygen-carrying ability to prolong survival ability, enhance proliferation activity, and preserve osteogenic differentiation potency and promote osteogenic-related genes expression of rat bone mesenchymal stem cells (rBMSCs) under hypoxic environment. Furthermore, the CS/HAp@PDA-F hydrogel can inhibit the growth of Staphylococcus aureus and Escherichia coli, providing a good antibacterial activity. Additionally, in vivo experiments demonstrate higher bone volume and bone mineral density, and more new bone tissue generation in CS/HAp@PDA-F group than in CS/HAp@PDA group. These results indicate that the rational design of fluorinated hydrogel possesses a good clinical application prospect for bone regeneration.
Collapse
Affiliation(s)
- Baoxuan Huang
- Shanghai Key Laboratory of Functional Materials Chemistry School of Chemistry and Molecular Engineering East China University of Science and Technology Meilong Road No. 130 Shanghai 200237 P. R. China
| | - Mingjiao Chen
- Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology Department of Ophthalmology Ninth People's Hospital Shanghai Jiao Tong University School of Medicine Zhizaoju Road No. 639 Shanghai 200011 P. R. China
| | - Jia Tian
- Shanghai Key Laboratory of Functional Materials Chemistry School of Chemistry and Molecular Engineering East China University of Science and Technology Meilong Road No. 130 Shanghai 200237 P. R. China
| | - Yuanhao Zhang
- Shanghai Key Laboratory of Functional Materials Chemistry School of Chemistry and Molecular Engineering East China University of Science and Technology Meilong Road No. 130 Shanghai 200237 P. R. China
| | - Zhaobo Dai
- Shanghai Key Laboratory of Functional Materials Chemistry School of Chemistry and Molecular Engineering East China University of Science and Technology Meilong Road No. 130 Shanghai 200237 P. R. China
| | - Jin Li
- Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology Department of Ophthalmology Ninth People's Hospital Shanghai Jiao Tong University School of Medicine Zhizaoju Road No. 639 Shanghai 200011 P. R. China
| | - Weian Zhang
- Shanghai Key Laboratory of Functional Materials Chemistry School of Chemistry and Molecular Engineering East China University of Science and Technology Meilong Road No. 130 Shanghai 200237 P. R. China
| |
Collapse
|
35
|
Ma L, Li G, Lei J, Song Y, Feng X, Tan L, Luo R, Liao Z, Shi Y, Zhang W, Liu X, Sheng W, Wu S, Yang C. Nanotopography Sequentially Mediates Human Mesenchymal Stem Cell-Derived Small Extracellular Vesicles for Enhancing Osteogenesis. ACS NANO 2022; 16:415-430. [PMID: 34935354 DOI: 10.1021/acsnano.1c07150] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Engineered small extracellular vesicles (sEVs) are used as tools to enhance therapeutic efficacy. However, such application of sEVs is associated with several issues, including high costs and a high risk of tumorigenesis. Nanotopography has a greater influence on bone-related cell behaviors. However, whether nanotopography specifically mediate sEV content to perform particular biological functions remains unclear. Here, we demonstrate that selective nanotopography may be used to sequentially mediate human bone mesenchymal stem cell (hBMSC) sEVs to enhance the therapeutic efficacy of hBMSCs-EVs for osteogenesis. We subjected sEVs harvested from hBMSCs cultured on polished titanium plates (Ti) or nanotopographical titanium plates (Ti4) after 7, 14, and 21 d for RNA sequencing, and we found that there was no significant difference in sEV-miRNA expression after 7 d. Differentially expressed osteogenic-related microRNAs were founded after 14 days, and KEGG analysis indicated that the main microRNAs were associated with osteogenesis-related pathways, such as TGF-beta, AMPK, and FoxO. A significant difference was found in sEV-miRNAs expression after 21 d. We loaded sEV secreted from hBMSCs cultured on Ti4 after 21 d on 3D-printed porous PEEK scaffolds with poly dopamine (PDA) and found that such scaffolds showed superior osteogenic ability after 6- and 12-weeks. Here, we demonstrate the alkali- and heat-treated nanotopography with the ability of stimulating osteogenic differentiation of hBMSC can induce the secretion of pro-osteogenesis sEV, and we also found that sEVs meditate osteogenesis through miRNA. Thus, whether nanotopography has the ability to regulate other contents of sEVs such as proteins for enhancing osteogenesis needs further research. These findings may help us use nanotopography to extract sEVs for other biomedical applications, including cancer therapy.
Collapse
Affiliation(s)
- Liang Ma
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Gaocai Li
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Jie Lei
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Yu Song
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Xiaobo Feng
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Lei Tan
- Biomedical Materials Engineering Research Center, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, Hubei Key Laboratory of Polymer Materials, Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, School of Materials Science & Engineering, Hubei University, Wuhan 430062, China
| | - Rongjin Luo
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Zhiwei Liao
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Yunsong Shi
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Weifeng Zhang
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Xiangmei Liu
- Biomedical Materials Engineering Research Center, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, Hubei Key Laboratory of Polymer Materials, Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, School of Materials Science & Engineering, Hubei University, Wuhan 430062, China
| | - Weibin Sheng
- Department of Spine Surgery, The First Affiliated Hospital of Xinjiang Medical University, Urumqi 830054, China
| | - Shuilin Wu
- The Key Laboratory of Advanced Ceramics and Machining Technology by the Ministry of Education of China, School of Materials Science & Engineering, Tianjin University, Tianjin 300072, China
| | - Cao Yang
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| |
Collapse
|
36
|
Wang Y, Wang P, Wu Q, Qin Z, Xiang Z, Chu Y, Li J. Loading of erythropoietin on biphasic calcium phosphate bioceramics promotes osteogenesis and angiogenesis by regulating EphB4/EphrinB2 molecules. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2022; 33:19. [PMID: 35072831 PMCID: PMC8786765 DOI: 10.1007/s10856-022-06644-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Accepted: 01/05/2022] [Indexed: 06/14/2023]
Abstract
Improving osteogenesis and angiogenesis using different cells and drugs is critical in the field of bone tissue engineering. Recent research has found that erythropoietin (EPO) plays an important role in both osteogenesis and angiogenesis. In this study, we grafted polydopamine and EPO onto the surface of biphasic calcium phosphate. The characterization and release property of the modified bioceramics were assessed. Cell proliferation, expression of osteoblastic and endothelial markers, and EphB4/EphrinB2 molecules were investigated while employing co-cultures of two different cells [rat vein endothelial cells (VECs) and rat bone marrow mesenchymal stromal cells (BMSCs)]. The modified bioceramics were finally implanted into the SD rats' femurs and followed by investigating the bone defect repair efficacy and the expression of EphB4/EphrinB2 molecules in vivo. The results indicated that the modified bioceramics could control the release of EPO continuously. The osteogenesis and angiogenesis were improved along with the increased expression of EphB4/EphrinB2 molecules. The expression of EphB4/EphrinB2 molecules was also significantly increased in vivo and the bone defect was repaired effectively. Overall, our findings demonstrated that EPO loading on biphasic calcium phosphate bioceramics could promote both osteogenesis and angiogenesis. The results suggest that EphB4/EphrinB2 may be crucial in the process. Graphical abstract.
Collapse
Affiliation(s)
- Yu Wang
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Orthognathic & TMJ Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China
| | - Peng Wang
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Orthognathic & TMJ Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China
| | - Qionghui Wu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Orthognathic & TMJ Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China
| | - Zhifan Qin
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Orthognathic & TMJ Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China
| | - Zichao Xiang
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Orthognathic & TMJ Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China
| | - Yuxian Chu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Orthognathic & TMJ Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China
| | - Jihua Li
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Orthognathic & TMJ Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China.
| |
Collapse
|
37
|
Dong W, Ma W, Zhao S, Zhou X, Wang Y, Liu Z, Sun D, Zhang M, Jiang Z. Multifunctional 3D sponge-like macroporous cryogel-modified long carbon fiber reinforced polyetheretherketone implant with enhanced vascularization and osseointegration. J Mater Chem B 2022; 10:5473-5486. [DOI: 10.1039/d2tb00725h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Long carbon fiber reinforced polyetheretherketone (LCFRPEEK), a newly developed high-performance composite material, is being investigated as a possible orthopedic implant. However, its inability of angiogenesis and osseointegration after implantation makes...
Collapse
|
38
|
Zhao H, Wang X, Zhang W, Wang L, Zhu C, Huang Y, Chen R, Chen X, Wang M, Pan G, Shi Q, Zhou X. Bioclickable Mussel-Derived Peptides With Immunoregulation for Osseointegration of PEEK. Front Bioeng Biotechnol 2021; 9:780609. [PMID: 34900969 PMCID: PMC8652040 DOI: 10.3389/fbioe.2021.780609] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Accepted: 10/25/2021] [Indexed: 02/01/2023] Open
Abstract
Polyether ether ketone (PEEK)–based biomaterials have been widely used in the field of spine and joint surgery. However, lack of biological activity limits their further clinical application. In this study, we synthesized a bioclickable mussel-derived peptide Azide-DOPA4 as a PEEK surface coating modifier and further combined bone morphogenetic protein 2 functional peptides (BMP2p) with a dibenzylcyclooctyne (DBCO) motif through bio-orthogonal reactions to obtain DOPA4@BMP2p-PEEK. As expected, more BMP2p can be conjugated on PEEK after Azide-DOPA4 coating. The surface roughness and hydrophilicity of DOPA4@BMP2p-PEEK were obviously increased. Then, we optimized the osteogenic capacity of PEEK substrates. In vitro, compared with the BMP2p-coating PEEK material, DOPA4@BMP2p-PEEK showed significantly higher osteogenic induction capability of rat bone marrow mesenchymal stem cells. In vivo, we constructed a rat calvarial bone defect model and implanted PEEK materials with a differently modified surface. Micro-computed tomography scanning displayed that the DOPA4@BMP2p-PEEK implant group had significantly higher new bone volume and bone mineral density than the BMP2p-PEEK group. Histological staining of hard tissue further confirmed that the DOPA4@BMP2p-PEEK group revealed a better osseointegrative effect than the BMP2p-PEEK group. More importantly, we also found that DOPA4@BMP2p coating has a synergistic effect with induced Foxp3+ regulatory T (iTreg) cells to promote osteogenesis. In summary, with an easy-to-perform, two-step surface bioengineering approach, the DOPA4@BMP2p-PEEK material reported here displayed excellent biocompatibility and osteogenic functions. It will, moreover, offer insights to engineering surfaces of orthopedic implants.
Collapse
Affiliation(s)
- Huan Zhao
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Orthopaedic Institute of Soochow University, Suzhou, China
| | - Xiaokang Wang
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Orthopaedic Institute of Soochow University, Suzhou, China.,Department of Orthopaedics, The Affiliated Maternity and Child Health Care Hospital of Nantong University, Nantong University, Nantong, China
| | - Wen Zhang
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Orthopaedic Institute of Soochow University, Suzhou, China
| | - Lin Wang
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Orthopaedic Institute of Soochow University, Suzhou, China
| | - Can Zhu
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Orthopaedic Institute of Soochow University, Suzhou, China
| | - Yingkang Huang
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Orthopaedic Institute of Soochow University, Suzhou, China
| | - Rongrong Chen
- Department of Pediatrics, The Affiliated Maternity and Child Health Care Hospital of Nantong University, Nantong University, Nantong, China
| | - Xu Chen
- Institute for Advanced Materials, School of Materials Science and Engineering, Jiangsu University, Zhenjiang, China
| | - Miao Wang
- Institute for Advanced Materials, School of Materials Science and Engineering, Jiangsu University, Zhenjiang, China
| | - Guoqing Pan
- Institute for Advanced Materials, School of Materials Science and Engineering, Jiangsu University, Zhenjiang, China
| | - Qin Shi
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Orthopaedic Institute of Soochow University, Suzhou, China
| | - Xichao Zhou
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Orthopaedic Institute of Soochow University, Suzhou, China
| |
Collapse
|
39
|
Sun Y, Li Y, Zhang Y, Wang T, Lin K, Liu J. A polydopamine-assisted strontium-substituted apatite coating for titanium promotes osteogenesis and angiogenesis via FAK/MAPK and PI3K/AKT signaling pathways. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 131:112482. [PMID: 34857268 DOI: 10.1016/j.msec.2021.112482] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 09/16/2021] [Accepted: 10/08/2021] [Indexed: 02/07/2023]
Abstract
Early osteointegration is essential for biomedical implants. Surface modifications can significantly compensate for an implant's lack of biocompatibility and osteo-differentiation. They can also be designed to promote angiogenesis in order to assist osteogenesis and ultimately facilitate bone regeneration. In this study, a polydopamine-assisted strontium-substituted apatite coating (Ti@PDA + SrHA) was fabricated on a multifunctional titanium implant to induce both angiogenic and osteogenic abilities for rapid osseointegration. Polydopamine and Sr-substituted hydroxyapatite were coated on the implant through biomineralization. The in vitro results showed that Ti@PDA + SrHA improved cell adhesion and increased the proliferation of rat bone marrow-derived mesenchymal stem cells (rBMSCs) and human umbilical vein endothelial cells (HUVECs). Ti@PDA + SrHA upregulated the expression of ALP activity and osteogenic genes in rBMSCs and elevated angiogenic genes in both rBMSCs and HUVECs. Mechanically, the FAK/MAPK signaling pathway was activated in rBMSCs, and the PI3K/AKT signaling pathway was activated in both rBMSCs and HUVECs. Consistent with these findings, Ti@PDA + SrHA accelerated new bone formation and rapid osseointegration in the femoral condyle implantation study with good stability. Overall, we fabricated a multifunctional biocompatible implant with better angiogenic and osteogenic performance compared to the non-coated implant.
Collapse
Affiliation(s)
- Yiting Sun
- Department of Oral & Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China; College of Stomatology, Shanghai Jiao Tong University, Shanghai 200011, China; National Center for Stomatology, Shanghai 200011, China; National Clinical Research Center for Oral Diseases, Shanghai 200011, China; Shanghai Key Laboratory of Stomatology, Shanghai 200011, China
| | - Yaxin Li
- Department of Oral & Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China; College of Stomatology, Shanghai Jiao Tong University, Shanghai 200011, China; National Center for Stomatology, Shanghai 200011, China; National Clinical Research Center for Oral Diseases, Shanghai 200011, China; Shanghai Key Laboratory of Stomatology, Shanghai 200011, China
| | - Yu Zhang
- College of Stomatology, Shanghai Jiao Tong University, Shanghai 200011, China; National Center for Stomatology, Shanghai 200011, China; National Clinical Research Center for Oral Diseases, Shanghai 200011, China; Shanghai Key Laboratory of Stomatology, Shanghai 200011, China; Department of Oral Maxillofacial-Head Neck Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China
| | - Tiange Wang
- Department of Oral & Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China; College of Stomatology, Shanghai Jiao Tong University, Shanghai 200011, China; National Center for Stomatology, Shanghai 200011, China; National Clinical Research Center for Oral Diseases, Shanghai 200011, China; Shanghai Key Laboratory of Stomatology, Shanghai 200011, China
| | - Kaili Lin
- Department of Oral & Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China; College of Stomatology, Shanghai Jiao Tong University, Shanghai 200011, China; National Center for Stomatology, Shanghai 200011, China; National Clinical Research Center for Oral Diseases, Shanghai 200011, China; Shanghai Key Laboratory of Stomatology, Shanghai 200011, China.
| | - Jiaqiang Liu
- Department of Oral & Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China; College of Stomatology, Shanghai Jiao Tong University, Shanghai 200011, China; National Center for Stomatology, Shanghai 200011, China; National Clinical Research Center for Oral Diseases, Shanghai 200011, China; Shanghai Key Laboratory of Stomatology, Shanghai 200011, China.
| |
Collapse
|
40
|
Wang H, Ma Y, Li J, Zhou C, Xu A, Xu Y, He F. Modulating autophagy by strontium-doped micro/nano rough titanium surface for promotion of osteogenesis and inhibition of osteoclastogenesis. Colloids Surf B Biointerfaces 2021; 210:112246. [PMID: 34883339 DOI: 10.1016/j.colsurfb.2021.112246] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Revised: 11/13/2021] [Accepted: 11/22/2021] [Indexed: 12/20/2022]
Abstract
Although it has been demonstrated that implant surfaces treated with strontium (Sr) promote osseointegration, the underlying intracellular mechanism remains unknown. Autophagy is a vital intracellular degradation mechanism that plays an essential role in maintaining bone homeostasis. Therefore, while designing implant biomaterials, it is critical to consider the autophagy mechanism. In this study, we fabricated Sr-doped micro/nano rough titanium implant surface by hydrothermal treatment (SLA+Sr). The in vitro results revealed that the SLA+Sr surface promoted osteogenic differentiation of bone marrow-derived mesenchymal stem cells (BMSCs) via autophagy activation. The SLA+Sr surface, on the other hand, inhibited osteoclast differentiation by downregulating autophagy. Additionally, in vivo, the SLA+Sr implant improved osseointegration, inhibited osteoclastogenesis, and upregulated autophagy levels in surrounding bone tissue cells. Our findings established a novel centralized mechanism by which SLA+Sr regulated osteogenesis and osteoclastogenesis during the osseointegration process through autophagy regulation. Moreover, endowing implants with the ability to modulate autophagy may be a promising strategy for enhancing implant osseointegration in the future translational medicine field.
Collapse
Affiliation(s)
- Hui Wang
- Zhejiang University, Stomatology Hospital, Department of Prosthodontics, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006
| | - Yang Ma
- Zhejiang University, Stomatology Hospital, Department of Prosthodontics, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006
| | - Jia Li
- Zhejiang University, Stomatology Hospital, Department of Prosthodontics, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006
| | - Chuan Zhou
- Zhejiang University, Stomatology Hospital, Department of Prosthodontics, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006
| | - Antian Xu
- Zhejiang University, Stomatology Hospital, Department of Prosthodontics, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006
| | - Yangbo Xu
- Zhejiang University, Stomatology Hospital, Department of Prosthodontics, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006
| | - Fuming He
- Zhejiang University, Stomatology Hospital, Department of Prosthodontics, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006.
| |
Collapse
|
41
|
Cui J, Xia L, Lin K, Wang X. In situ construction of a nano-structured akermanite coating for promoting bone formation and osseointegration of Ti-6Al-4V implants in a rabbit osteoporosis model. J Mater Chem B 2021; 9:9505-9513. [PMID: 34747422 DOI: 10.1039/d1tb01917a] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
With the aging population worldwide, osteoporosis, as an age-related bone metabolic disease, is becoming a hot issue in public health. However, it is still a great challenge to realize osteoporotic bone healing due to the alteration of the bone microenvironment in osteoporosis patients. In this study, a nano-structured akermanite (nAK) coating was in situ constructed on Ti-6Al-4V implants to improve osteoporotic bone repair. In vitro studies indicated that both the surface nano-topography and bioactive ions released from the nAK coatings promoted the proliferation, osteogenesis, angiogenesis and inhibited osteoclastogenesis of ovariectomy rabbit-derived bone marrow mesenchymal stem cells (OVX-rBMSCs). Furthermore, the nAK-coated Ti-6Al-4V implants improved new bone formation and osseointegration in an osteoporosis rabbit model in vivo. These results indicated that the AK coating with a nano-structured surface on the Ti-6Al-4V implant could synergistically promote bone formation and osseointegration for osteoporosis patients. This may be a promising strategy to improve the bone regeneration and osseointegration capability of orthopedic implants under osteoporosis conditions.
Collapse
Affiliation(s)
- Jinjie Cui
- Department of Oral and Cranio-maxillofacial Science, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai 200011, China.
| | - Lunguo Xia
- Department of Oral and Cranio-maxillofacial Science, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai 200011, China.
| | - Kaili Lin
- Department of Oral and Cranio-maxillofacial Science, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai 200011, China.
| | - Xiuhui Wang
- Institute of Translational Medicine, Shanghai University, Shanghai 200011, China.
| |
Collapse
|
42
|
Wang S, Lao W, He Y, Shi H, Ye Q, Ma J. Promoting the stability and adsorptive capacity of Fe 3O 4-embedded expanded graphite with an aminopropyltriethoxysilane-polydopamine coating for the removal of copper(ii) from water. RSC Adv 2021; 11:35673-35686. [PMID: 35493170 PMCID: PMC9043260 DOI: 10.1039/d1ra05160a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Accepted: 10/22/2021] [Indexed: 01/07/2023] Open
Abstract
In this study, three magnetic graphites, namely, EGF, GAF, and GFA + KH550, were prepared, which were loaded either with Fe3O4 or with Fe3O4 and PDA or with Fe3O4, PDA, and KH550 onto expanded graphite. ATR-FTIR, XRD, XPS, SEM, TEM, and TGA characterization results showed that EGF, GAF, and GFA + KH550 were successfully prepared. Under the same initial copper concentration, the removal rates of copper ions by EGF, GFA, and GFA + KH550 were 86.2%, 96.9%, and 97.0%, respectively and the hazard index reductions of the three adsorbents were 2191 ± 71 (EGF), 1843 ± 68 (GFA), and 1664 ± 102 (GFA + KH550), respectively. Therefore GFA + KH550 exhibited better removal of Cu(ii) than EGF and GFA, for PDA and KH550 provided more adsorption-active sites like –OH and –NH. Here, the adsorption of GFA + KH550 fitted the pseudo-second-order kinetic and Langmuir models well within the testing range, which means that adsorption occurs on a monolayer surface between Cu(ii) and the adsorption sites. The intraparticle diffusion model and various thermodynamic parameters demonstrated that Cu(ii) was adsorbed on GFA + KH550 mainly via external surface diffusion and that the process was both endothermic and spontaneous. Recycling experiments show that GFA + KH550 has a satisfactory recyclability, and the way of direct recovery by magnets exhibits good magnetic induction. GFA + KH550 was applied in lake water and artificial seawater samples, and exhibited better removal of copper than that in DI water under the same environmental conditions for the existence of macromolecular organic matter. Furthermore, the adsorption capacity of copper ions was not relative to the salinity of water. The application of GFA + KH550 demonstrated the potential for application in water treatment procedures. In this study, three magnetic graphites, namely, EGF, GAF, and GFA + KH550, were prepared, which were loaded either with Fe3O4 or with Fe3O4 and PDA or with Fe3O4, PDA, and KH550 onto expanded graphite.![]()
Collapse
Affiliation(s)
- Shunhui Wang
- School of Chemistry and Chemical Engineering, Oil & Gas Field Applied Chemistry Key Laboratory of Sichuan Province, Southwest Petroleum University Chengdu 610500 China +86 28 83037367
| | - Wenjian Lao
- Southern California Coastal Water Research Project Authority Costa Mesa California 92626 USA
| | - Yi He
- School of Chemistry and Chemical Engineering, Oil & Gas Field Applied Chemistry Key Laboratory of Sichuan Province, Southwest Petroleum University Chengdu 610500 China +86 28 83037367.,State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation Chengdu Sichuan 610500 China
| | - Heng Shi
- School of Chemistry and Chemical Engineering, Oil & Gas Field Applied Chemistry Key Laboratory of Sichuan Province, Southwest Petroleum University Chengdu 610500 China +86 28 83037367
| | - Qihang Ye
- School of Chemistry and Chemical Engineering, Oil & Gas Field Applied Chemistry Key Laboratory of Sichuan Province, Southwest Petroleum University Chengdu 610500 China +86 28 83037367
| | - Jing Ma
- School of Chemistry and Chemical Engineering, Oil & Gas Field Applied Chemistry Key Laboratory of Sichuan Province, Southwest Petroleum University Chengdu 610500 China +86 28 83037367
| |
Collapse
|
43
|
An excellent antibacterial and high self-adhesive hydrogel can promote wound fully healing driven by its shrinkage under NIR. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 129:112395. [PMID: 34579914 DOI: 10.1016/j.msec.2021.112395] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 08/04/2021] [Accepted: 08/25/2021] [Indexed: 11/24/2022]
Abstract
The lacks of antibacterial properties, low adhesion and delayed wound healing of the hydrogel wound dressings limit their applications in wound treatment. To resolve these, a novel hydrogel composed of polydopamine (PDA), Ag and graphene oxide (GO) is fabricated for wound dressing via the chemical crosslinking of N-isopropylacrylamide (NIPAM) and N,N'-methylene bisacrylamide (BIS). The prepared hydrogel containing PDA@Ag5GO1 (Ag5GO1 denotes the mass ratio between Ag and GO is 5:1) exhibits effective antibacterial properties and high inhibition rate against E. coli and S. aureus. It shows high adhesion ability to various substrate materials, implying a simpler method to the wound obtained by self-fixing rather than suturing. More important, it can produce strong contractility under the irradiation of near-infrared light (NIR), exerting a centripetal force that helps accelerate wound healing. Thus, the hydrogel containing a high concentration PDA@Ag5GO1 irradiated by NIR can completely repair the wound defect (1.0 × 1.0 cm2) within 15 days, the wound healing rate can reach 100%, which was far higher than other groups. Taken together, the new hydrogel with excellent antibacterial, high adhesion and strong contractility will subvert the traditional treatment methods on wound defect, extending its new application range in wound dressing.
Collapse
|
44
|
Controlled release of dopamine coatings on titanium bidirectionally regulate osteoclastic and osteogenic response behaviors. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 129:112376. [PMID: 34579895 DOI: 10.1016/j.msec.2021.112376] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 07/23/2021] [Accepted: 08/10/2021] [Indexed: 12/31/2022]
Abstract
Bone diseases, for example, osteoporosis, cause excessive differentiation of osteoclasts and decreased bone formation, resulting in imbalance of bone remodeling and poor osseointegration, which can be considered a relative contraindication for titanium implants. Dopamine (DA) might provide a solution to this problem by inhibiting osteoclasts and promoting osteoblasts at different concentrations. However, current commercial implants cannot load bone-active molecules, such as DA. Therefore, this study aimed to develop a surface modification method for implants to achieve a controlled release of DA and enhance the resistance of titanium implants to bone resorption and bone regeneration. DA-loaded alginate-arginine-glycine-aspartic acid (RGD) (AlgR) coatings on a vaterite-modified titanium surface were successfully assembled, which continuously and steadily released DA. In vitro studies have shown that materials showing good biocompatibility can not only inhibit receptor activator of nuclear factor-kappa B (NFκB) ligand (RANKL)-induced osteoclastogenesis but also enhance the adhesion and osteogenic differentiation of human bone marrow mesenchymal stem cells (hBMSCs). The optimal DA-loaded concentration of this bidirectional regulation is 100 μM. Interestingly, DA more effectively attenuated osteoclastogenesis when released in a sustained manner from titanium coatings than it did via traditional, free administration, and the alginate-RGD coating and DA clearly exhibited great synergy. This study provides a design of titanium implant surface modification to improve bone remodeling around implants.
Collapse
|
45
|
Zheng D, Huang C, Zhu X, Huang H, Xu C. Performance of Polydopamine Complex and Mechanisms in Wound Healing. Int J Mol Sci 2021; 22:10563. [PMID: 34638906 PMCID: PMC8508909 DOI: 10.3390/ijms221910563] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Revised: 09/26/2021] [Accepted: 09/27/2021] [Indexed: 12/15/2022] Open
Abstract
Polydopamine (PDA) has been gradually applied in wound healing of various types in the last three years. Due to its rich phenol groups and unique structure, it can be combined with a variety of materials to form wound dressings that can be used for chronic infection, tissue repair in vivo and serious wound healing. PDA complex has excellent mechanical properties and self-healing properties, and it is a stable material that can be used for a long period of time. Unlike other dressings, PDA complexes can achieve both photothermal therapy and electro activity. In this paper, wound healing is divided into four stages: antibacterial, anti-inflammatory, cell adhesion and proliferation, and re-epithelialization. Photothermal therapy can improve the bacteriostatic rate and remove reactive oxygen species to inhibit inflammation. Electrical signals can stimulate cell proliferation and directional migration. With low reactive oxygen species (ROS) levels, inflammatory factors are down-regulated and growth factors are up-regulated, forming regular collagen fibers and accelerating wound healing. Finally, five potential development directions are proposed, including increasing drug loading capacity, optimization of drug delivery platforms, improvement of photothermal conversion efficiency, intelligent electroactive materials and combined 3D printing.
Collapse
Affiliation(s)
| | - Chongxing Huang
- School of Light Industry & Food Engineering, Guangxi University, Daxue Road 100, Nanning 530000, China; (D.Z.); (X.Z.); (H.H.); (C.X.)
| | | | | | | |
Collapse
|
46
|
Shao H, Cheng S, Yao M, Ji X, Zhong H, Wang D, Fan X, Li Q, Zhou J, Zhang Y, Peng F. A pH-response chemotherapy synergistic photothermal therapy for tumor suppression and bone regeneration by mussel-inspired Mg implant. Regen Biomater 2021; 8:rbab053. [PMID: 34557310 PMCID: PMC8455343 DOI: 10.1093/rb/rbab053] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 08/17/2021] [Accepted: 08/30/2021] [Indexed: 12/18/2022] Open
Abstract
Primary malignant bone tumors can be life-threatening. Surgical resection of tumor plus chemotherapy is the standard clinical treatment. However, postoperative recovery is hindered due to tumor recurrence caused by residual tumor cells and bone defect caused by resection of tumor tissue. Herein, a multifunctional mussel-inspired film was fabricated on Mg alloy, that is, an inner hydrothermal-treated layer, a middle layer of polydopamine, and an outer layer of doxorubicin. The modified Mg alloy showed excellent photothermal effect and thermal/pH-controlled release of doxorubicin. The synergistic effect of chemotherapy and photothermal therapy enabled the modified Mg alloy to kill bone tumor in vitro and inhibit tumor growth in nude mice. Moreover, because of the controlled release of Mg ions and biocompatibility of polydopamine, the modified Mg alloy supported extracellular matrix mineralization, alkaline phosphatase activity, and bone-related gene expression in C3H10T1/2. Bone implantation model in rats verified that the modified Mg showed excellent osteointegration. These findings prove that the use of mussel-inspired multifunction film on Mg alloy offers a promising strategy for the therapy of primary malignant bone tumor.
Collapse
Affiliation(s)
- Hongwei Shao
- Department of Orthopedics, Research Center of Medical Sciences, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106, Zhongshan 2nd Road, Yuexiu District, Guangzhou, Guangdong 510080, China.,School of Medicine, South China University of Technology, Guangzhou University Town, Panyu District, Guangzhou, Guangdong 510006, China
| | - Shi Cheng
- Department of Orthopedics, Research Center of Medical Sciences, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106, Zhongshan 2nd Road, Yuexiu District, Guangzhou, Guangdong 510080, China
| | - Mengyu Yao
- Department of Orthopedics, Research Center of Medical Sciences, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106, Zhongshan 2nd Road, Yuexiu District, Guangzhou, Guangdong 510080, China
| | - Xiongfa Ji
- Department of Orthopedics, Research Center of Medical Sciences, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106, Zhongshan 2nd Road, Yuexiu District, Guangzhou, Guangdong 510080, China
| | - Hua Zhong
- Department of Orthopedics, The Fifth Affiliated Hospital of Southern Medical University, No. 566 Congcheng Avenue, Conghua District, Guangzhou, Guangdong 510900, China
| | - Donghui Wang
- School of Materials Science and Engineering, Hebei University of Technology, No. 5340 Xiping Road, Beichen District, Tianjin 300130, China
| | - Xiujuan Fan
- Department of Orthopedics, The Second School of Clinical Medicine, Southern Medical University, No. 111 Liuhua Road, Yuexiu District, Guangzhou, Guangdong 510515, China
| | - Qian Li
- Department of Orthopedics, Research Center of Medical Sciences, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106, Zhongshan 2nd Road, Yuexiu District, Guangzhou, Guangdong 510080, China
| | - Jielong Zhou
- Department of Orthopedics, Research Center of Medical Sciences, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106, Zhongshan 2nd Road, Yuexiu District, Guangzhou, Guangdong 510080, China.,Institute of New Materials, Guangdong Academy of Sciences, No. 363 Changxing Road, Tianhe District, Guangzhou, Guangdong 510651, China
| | - Yu Zhang
- Department of Orthopedics, Research Center of Medical Sciences, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106, Zhongshan 2nd Road, Yuexiu District, Guangzhou, Guangdong 510080, China.,School of Medicine, South China University of Technology, Guangzhou University Town, Panyu District, Guangzhou, Guangdong 510006, China.,Institute of New Materials, Guangdong Academy of Sciences, No. 363 Changxing Road, Tianhe District, Guangzhou, Guangdong 510651, China
| | - Feng Peng
- Department of Orthopedics, Research Center of Medical Sciences, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106, Zhongshan 2nd Road, Yuexiu District, Guangzhou, Guangdong 510080, China
| |
Collapse
|
47
|
Tang Y, Tan Y, Lin K, Zhu M. Research Progress on Polydopamine Nanoparticles for Tissue Engineering. Front Chem 2021; 9:727123. [PMID: 34552912 PMCID: PMC8451720 DOI: 10.3389/fchem.2021.727123] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 08/18/2021] [Indexed: 01/20/2023] Open
Abstract
Tissue engineering is an interdisciplinary field that aims to develop biological substitutes for the replacement, repair, or enhancement of tissue function. The physical and chemical characteristics of biomaterials exert a profound influence on the biological responses and the following biofunction. Nanostructured coatings have been widely applied as an effective surface modification strategy to improve the bioactivity of biomaterials. Especially, polydopamine and polydopamine-derived nanoparticles are found with excessive adhesiveness, redox activity, photothermal conversion capacity, paramagnetism and conductivity other than excellent biocompatibility, and hydrophilicity. In this article, advances about polydopamine nanoparticles in tissue engineering applications are reviewed, including the repair of bone, cartilage, skin, heart, and nerve, to provide strategies for future biomaterial design.
Collapse
Affiliation(s)
- Yanmei Tang
- Department of Oral and Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology and Shanghai Research Institute of Stomatology, Shanghai, China
| | - Yu Tan
- Second Dental Clinic, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology and Shanghai Research Institute of Stomatology, Shanghai, China
| | - Kaili Lin
- Department of Oral and Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology and Shanghai Research Institute of Stomatology, Shanghai, China
| | - Min Zhu
- Department of Oral and Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology and Shanghai Research Institute of Stomatology, Shanghai, China
| |
Collapse
|
48
|
Zhang Y, Wu H, Yuan B, Zhu X, Zhang K, Zhang X. Enhanced osteogenic activity and antibacterial performance in vitro of polyetheretherketone by plasma-induced graft polymerization of acrylic acid and incorporation of zinc ions. J Mater Chem B 2021; 9:7506-7515. [PMID: 34551053 DOI: 10.1039/d1tb01349a] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Polyetheretherketone (PEEK) has been widely used in the fields of orthopedics and trauma, but weak osteointegration and bacterial infection affect its long-term stability and repair effects. Surface modification is an effective way to improve the osteogenic and antibacterial activity of PEEK implants. In the present study, a layer of acrylic acid (AA) polymer coating loaded with zinc ions (Zn2+) was constructed on the surface of PEEK (PEEK-AA-Zn) using a strategy of combining plasma-induced graft polymerization with a chemical immersion technique. Successful construction of the AA coating remarkably enhanced the hydrophilicity of PEEK, and effectively loaded and released Zn2+. In vitro cell culture using MC3T3-E1 preosteoblasts showed that the Zn2+ released from PEEK-AA-Zn promoted cell proliferation and elevated gene expression levels of alkaline phosphatase (ALP), osteocalcin (OCN) and bone sialoprotein (BSP). Antibacterial tests revealed that PEEK-AA-Zn efficiently inhibited the proliferation of Staphylococcus aureus (S. aureus). These results suggest that the combined method of graft polymerization and ion incorporation endows PEEK with excellent osteogenic and antibacterial activity, which provides a wide range of possibilities for developing PEEK implants with multifunctional properties for bone tissue repair.
Collapse
Affiliation(s)
- Yuxiang Zhang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610064, China.
| | - Hongfeng Wu
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610064, China.
| | - Bo Yuan
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610064, China.
| | - Xiangdong Zhu
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610064, China.
| | - Kai Zhang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610064, China.
| | - Xingdong Zhang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610064, China.
| |
Collapse
|
49
|
Yao M, Cheng S, Zhong G, Zhou J, Shao H, Ma L, Du C, Peng F, Zhang Y. Enhanced osteogenesis of titanium with nano-Mg(OH) 2 film and a mechanism study via whole genome expression analysis. Bioact Mater 2021; 6:2729-2741. [PMID: 33665504 PMCID: PMC7895731 DOI: 10.1016/j.bioactmat.2021.02.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 02/01/2021] [Accepted: 02/02/2021] [Indexed: 02/07/2023] Open
Abstract
Titanium (Ti) has been the most widely used orthopedic implant in the past decades. However, their inert surface often leads to insufficient osteointegration of Ti implant. To solve this issue, two bioactive Mg(OH)2 films were developed on Ti surfaces using hydrothermal treatment (Ti-M1# and Ti-M2#). The Mg(OH)2 films showed nano-flake structures: sheets on Ti-M1# with a thickness of 14.7 ± 0.7 nm and a length of 131.5 ± 2.9 nm, and on Ti-M2# with a thickness of 13.4 ± 2.2 nm and a length of 56.9 ± 5.6 nm. Both films worked as Mg ions releasing platforms. With the gradual degradation of Mg(OH)2 films, weakly alkaline microenvironments will be established surrounding the modified implants. Benefiting from the sustained release of Mg ions, nanostructures, and weakly alkaline microenvironments, the as-prepared nano-Mg(OH)2 coated Ti showed better in vitro and in vivo osteogenesis. Notably, Ti-M2# showed better osteogenesis than Ti-M1#, which can be ascribed to its smaller nanostructure. Moreover, whole genome expression analysis was applied to study the osteogenic mechanism of nano-Mg(OH)2 films. For both coated samples, most of the genes related to ECM-receptor interaction, focal adhesion, and TGF-β pathways were upregulated, indicating that these signaling pathways were activated, leading to better osteogenesis. Furthermore, cells cultured on Ti-M2# showed markedly upregulated BMP-4 gene expression, suggesting that the nanostructure with Mg ion release ability can better activate BMP-4 related signaling pathways, resulting in better osteogenesis. Nano-Mg(OH)2 films demonstrated a superior osteogenesis and are promising surface modification strategy for orthopedic applications.
Collapse
Affiliation(s)
- Mengyu Yao
- Department of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou, 510641, China
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, 510080, China
| | - Shi Cheng
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, 510080, China
| | - Guoqing Zhong
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, 510080, China
- Shantou University Medical College, Shantou, 515041, Guangdong, China
| | - Jielong Zhou
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, 510080, China
| | - Hongwei Shao
- Department of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou, 510641, China
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, 510080, China
| | - Limin Ma
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, 510080, China
| | - Chang Du
- Department of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou, 510641, China
- Corresponding author.
| | - Feng Peng
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, 510080, China
- Corresponding author.
| | - Yu Zhang
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, 510080, China
- Corresponding author.
| |
Collapse
|
50
|
Wang G, Qian G, Yao J, Cai W, Peng S, Shuai C. Polydopamine-decorated black phosphorous to enhance stability in polymer scaffold. NANOTECHNOLOGY 2021; 32:455701. [PMID: 34330108 DOI: 10.1088/1361-6528/ac1977] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 07/30/2021] [Indexed: 06/13/2023]
Abstract
Black phosphorous (BP) is recognized as an effective reinforcement for polymer scaffold because of its excellent mechanical property and biocompatibility. Nevertheless, its poor stability in physiological environment limits its application in bone repair. In this work, BP was modified with dopamine by self-polymerization approach (donated as BP@PDA) to improve its stability, and then was introduced into poly-L-lactic acid (PLLA) scaffold fabricated by selective laser sintering technology. Results showed the compressive and tensile strength of PLLA/BP@PDA scaffold were improved by 105% and 50%, respectively. The enhanced strength was ascribed to the increased stability of BP and the improved compatibility of BP@PDA with PLLA matrix after modifying with polydopamine. Simultaneously, the bioactivity of PLLA scaffold was significantly improved. It was attributed to that BP@PDA provided the sustained source ofPO43-ions which could capture Ca2+ions from physiological medium to facilitatein situbiomineralization, thereby promoting cell adhesion, proliferation and differentiation. This study demonstrated the great potential of BP@PDA in bone repair.
Collapse
Affiliation(s)
- Guoyong Wang
- Institute of Bioadditive Manufacturing, Jiangxi University of Science and Technology, Nanchang 330013, People's Republic of China
| | - Guowen Qian
- Institute of Bioadditive Manufacturing, Jiangxi University of Science and Technology, Nanchang 330013, People's Republic of China
| | - Jia Yao
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, Hunan 410011, People's Republic of China
| | - Weiliang Cai
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, Hunan 410011, People's Republic of China
| | - Shuping Peng
- NHC Key Laboratory of Carcinogenesis, The Key Laboratory of Carcinogenesis and Cancer Invasion of the Chinese Ministry of Education, School of Basic Medical Science, Central South University, Changsha, 410078 Hunan People's Republic of China
- School of energy and mechanical engineering, Jiangxi University of Science and Technology, Nanchang 330013, People's Republic of China
| | - Cijun Shuai
- Institute of Bioadditive Manufacturing, Jiangxi University of Science and Technology, Nanchang 330013, People's Republic of China
- Shenzhen Institute of Information Technology, Shenzhen 518172, People's Republic of China
- State Key Laboratory of High Performance Complex Manufacturing, Central South University, Changsha 410083, People's Republic of China
| |
Collapse
|