1
|
Köksaldı İÇ, Avcı E, Köse S, Özkul G, Kehribar EŞ, Şafak Şeker UÖ. Genetically engineered bacterial biofilm materials enhances portable whole cell sensing. Biosens Bioelectron 2024; 264:116644. [PMID: 39137519 DOI: 10.1016/j.bios.2024.116644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Revised: 07/16/2024] [Accepted: 08/07/2024] [Indexed: 08/15/2024]
Abstract
In recent years, whole-cell biosensors (WCBs) have emerged as a potent approach for environmental monitoring and on-site analyte detection. These biosensors harness the biological apparatus of microorganisms to identify specific analytes, offering advantages in sensitivity, specificity, and real-time monitoring capabilities. A critical hurdle in biosensor development lies in ensuring the robust attachment of cells to surfaces, a crucial step for practical utility. In this study, we present a comprehensive approach to tackle this challenge via engineering Escherichia coli cells for immobilization on paper through the Curli biofilm pathway. Furthermore, incorporating a cellulose-binding peptide domain to the CsgA biofilm protein enhances cell adhesion to paper surfaces, consequently boosting biosensor efficacy. To demonstrate the versatility of this platform, we developed a WCB for copper, optimized to exhibit a discernible response, even with the naked eye. To confirm its suitability for practical field use, we characterized our copper sensor under various environmental conditions-temperature, salinity, and pH-to mimic real-world scenarios. The biosensor-equipped paper discs can be freeze-dried for deployment in on-site applications, providing a practical method for long-term storage without loss of sensitivity paper discs demonstrate sustained functionality and viability even after months of storage with 5 μM limit of detection for copper with visible-to-naked-eye signal levels. Biofilm-mediated surface attachment and analyte sensing can be independently engineered, allowing for flexible utilization of this platform as required. With the implementation of copper sensing as a proof-of-concept study, we underscore the potential of WCBs as a promising avenue for the on-site detection of a multitude of analytes.
Collapse
Affiliation(s)
- İlkay Çisil Köksaldı
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey; Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey
| | - Ece Avcı
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey; Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey
| | - Sıla Köse
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey; Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey
| | - Gökçe Özkul
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey; Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey
| | - Ebru Şahin Kehribar
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey; Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey
| | - Urartu Özgür Şafak Şeker
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey; Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey.
| |
Collapse
|
2
|
Duda M, Joshi P, Borodziuk A, Sobczak K, Sikora-Dobrowolska B, Maćkowski S, Dennis AM, Kłopotowski Ł. Multimodal Temperature Readout Boosts the Performance of CuInS 2/ZnS Quantum Dot Nanothermometers. ACS APPLIED MATERIALS & INTERFACES 2024. [PMID: 39437320 DOI: 10.1021/acsami.4c14541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2024]
Abstract
Fluorescent nanothermometers are positioned to revolutionize research into cell functions and provide strategies for early diagnostics. Fluorescent nanostructures hold particular promise to fulfill this potential if nontoxic, stable varieties allowing for precise temperature measurement with high thermal sensitivities can be fabricated. In this work, we investigate the performance of micelle-encapsulated CuInS2/ZnS core/shell colloidal quantum dots (QDs) as fluorescent nanothermometers. We demonstrate four temperature readout modes, which are based on variations in the photoluminescence intensity, energy, and lifetime and on a specific ratio of excitation efficiencies. We further leverage this multimodal readout to construct a fifth, multiparametric thermometer calibration based on the multiple linear regression (MLR) model. We show that the MLR approach boosts the thermometer sensitivity by up to 7-fold while reducing the readout error by about a factor of 3. As a result, our QDs offer the highest sensitivities among semiconducting QDs emitting in the first biological window. The obtained results indicate that CuInS2/ZnS QDs are excellent candidates for intracellular in vivo thermometry and provide guidelines for further optimization of their performance.
Collapse
Affiliation(s)
- Magdalena Duda
- Institute of Physics, Polish Academy of Sciences, 02-668 Warsaw, Poland
| | - Pushkar Joshi
- Institute of Physics, Polish Academy of Sciences, 02-668 Warsaw, Poland
| | - Anna Borodziuk
- Institute of Physics, Polish Academy of Sciences, 02-668 Warsaw, Poland
| | - Kamil Sobczak
- University of Warsaw Biological and Chemical Research Centre, 02-089 Warsaw, Poland
| | | | - Sebastian Maćkowski
- Institute of Physics, Faculty of Physics, Nicolaus Copernicus University, Astronomy and Informatics, 87-100 Toruń, Poland
| | - Allison M Dennis
- Department of Chemical Engineering, Northeastern University, Boston, Massachusetts 02115, United States
| | | |
Collapse
|
3
|
Fricke TC, Leffler A. TRPV2: a universal regulator in cellular physiology with a yet poorly defined thermosensitivity. J Physiol Sci 2024; 74:42. [PMID: 39285320 PMCID: PMC11403965 DOI: 10.1186/s12576-024-00936-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2024] [Accepted: 08/31/2024] [Indexed: 09/22/2024]
Abstract
Transient receptor potential (TRP) ion channels serve as sensors for variations in ambient temperature, modulating both thermoregulation and temperature responsive cellular processes. Among these, the vanilloid TRP subfamily (TRPV) comprises six members and at least four of these members (TRPV1-TRPV4) have been associated with thermal sensation. TRPV2 has been described as a sensor for noxious heat, but subsequent studies have unveiled a more complex role for TRPV2 beyond temperature perception. This comprehensive review aims to elucidate the intricate thermosensitivity of TRPV2 by synthesizing current knowledge on its biophysical properties, expression pattern and known physiological functions associated with thermosensation.
Collapse
Affiliation(s)
- Tabea C Fricke
- Department of Anesthesiology and Intensive Care Medicine, Hannover Medical School, Carl-Neuberg Strasse 1, 30625, Hannover, Germany
| | - Andreas Leffler
- Department of Anesthesiology and Intensive Care Medicine, Hannover Medical School, Carl-Neuberg Strasse 1, 30625, Hannover, Germany.
| |
Collapse
|
4
|
Fukushima SI, Wazawa T, Sugiura K, Nagai T. Extremely Sensitive Genetically Encoded Temperature Indicator Enabling Measurement at the Organelle Level. ACS Sens 2024; 9:3889-3897. [PMID: 39042704 PMCID: PMC11348412 DOI: 10.1021/acssensors.3c02658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 07/18/2024] [Accepted: 07/19/2024] [Indexed: 07/25/2024]
Abstract
Intracellular temperature is a fundamental parameter in biochemical reactions. Genetically encoded fluorescent temperature indicators (GETIs) have been developed to visualize intracellular thermogenesis; however, the temperature sensitivity or localization capability in specific organelles should have been further improved to clearly capture when and where intracellular temperature changes at the subcellular level occur. Here, we developed a new GETI, gMELT, composed of donor and acceptor subunits, in which cyan and yellow fluorescent proteins, respectively, as a Förster resonance energy transfer (FRET) pair were fused with temperature-sensitive domains. The donor and acceptor subunits associated and dissociated in response to temperature changes, altering the FRET efficiency. Consequently, gMELT functioned as a fluorescence ratiometric indicator. Untagged gMELT was expressed in the cytoplasm, whereas versions fused with specific localization signals were targeted to the endoplasmic reticulum (ER) or mitochondria. All gMELT variations enabled more sensitive temperature measurements in cellular compartments than those in previous GETIs. The gMELTs, tagged with ER or mitochondrial targeting sequences, were used to detect thermogenesis in organelles stimulated chemically, a method previously known to induce thermogenesis. The observed temperature changes were comparable to previous reports, assuming that the fluorescence readout changes were exclusively due to temperature variations. Furthermore, we demonstrated how macromolecular crowding influences gMELT fluorescence given that this factor can subtly affect the fluorescence readout. Investigating thermogenesis with gMELT, accounting for factors such as macromolecular crowding, will enhance our understanding of intracellular thermogenesis phenomena.
Collapse
Affiliation(s)
| | | | | | - Takeharu Nagai
- SANKEN, The University of Osaka, Ibaraki, Osaka 567-0047, Japan
- OTRI, The University of Osaka, Suita, Osaka 565-0871, Japan
- Research
Institute for Electronic Science, Hokkaido
University, Sapporo, Hokkaido 001-0021, Japan
| |
Collapse
|
5
|
Rusch G, Wang J, Breau K, Kilgour K, Gilleskie G, Keele J, Selle K, Magness ST, Menegatti S, Daniele M. Comparative Approaches for Quantification of Product Yield in a Model Recombinant Green Fluorescent Protein Expressed in E. coli. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.06.24.600411. [PMID: 38979374 PMCID: PMC11230288 DOI: 10.1101/2024.06.24.600411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/10/2024]
Abstract
Process Analytical Technologies (PAT) used to monitor and control manufacturing processes are crucial for efficient and automated bioprocessing, which is in congruence with lights-off-manufacturing and Industry 4.0 initiatives. As biomanufacturing seeks to realize more high-throughput and automated operation, an increasing need for multimodal analysis of process metrics becomes essential. Herein, we detail a series of methods for analyzing product yield from a bioreactor and how to conduct cross-method comparisons. We employ a model system of Escherichia coli (E. coli) expression of green fluorescent protein (GFP), which is a simple, cost effective model for students and educators to replicate at different scales. GFP is an ideal analytical marker as it is easy to visualize due to its fluorescence which indicates cellular protein expression, cell localization and physiological changes of the cell population. In this study, samples from a 300 L bioreactor with GFP-expressing E. coli are analyzed to improve product yield and bioprocessing efficiency. Utilizing a fed-batch process for enhanced cell density and product titer, this bioreactor runs on a 24-hour schedule from inoculation to GFP induction and final harvest. To reliably quantify relative GFP expression and E. coli proliferation, we provide simple protocols and example results for comparing three different analytical methods: (1) in-line bioreactor measurements, (2) plate reader assays, and (3) microscopy. The GFP and cell density results follow similar trends based on the various inline and offline analytical methods and show a peak of GFP expression and cell density between 12.5 and 18 hours post inoculation.
Collapse
Affiliation(s)
- Gabrielle Rusch
- Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina, Chapel Hill, 911 Oval Dr., Raleigh, NC 27695 (USA)
- Comparative Medicine Institute, North Carolina State University, 1060 William Moore Dr., Raleigh, NC 27606 (USA)
| | - Junhyeong Wang
- Department of Electrical & Computer Engineering, North Carolina State University, 890 Oval Dr., Raleigh NC, 27695 (USA)
| | - Keith Breau
- Department of Cell Biology and Physiology, University of North Carolina, Chapel Hill, 111 Mason Farm Road, Chapel Hill, NC 27599 (USA)
| | - Katie Kilgour
- Department of Chemical Engineering, North Carolina State University, 911 Partners Way, Raleigh, NC 27695 (USA)
| | - Gary Gilleskie
- Golden LEAF Biomanufacturing Training and Education Center (BTEC), NC State University, Raleigh, NC 27695 (USA)
| | - Jeff Keele
- Golden LEAF Biomanufacturing Training and Education Center (BTEC), NC State University, Raleigh, NC 27695 (USA)
| | - Kurt Selle
- Golden LEAF Biomanufacturing Training and Education Center (BTEC), NC State University, Raleigh, NC 27695 (USA)
| | - Scott T. Magness
- Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina, Chapel Hill, 911 Oval Dr., Raleigh, NC 27695 (USA)
| | - Stefano Menegatti
- Department of Chemical Engineering, North Carolina State University, 911 Partners Way, Raleigh, NC 27695 (USA)
| | - Michael Daniele
- Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina, Chapel Hill, 911 Oval Dr., Raleigh, NC 27695 (USA)
- Comparative Medicine Institute, North Carolina State University, 1060 William Moore Dr., Raleigh, NC 27606 (USA)
| |
Collapse
|
6
|
Cheng Y, Wu J, Cui Y, Zhai J, Wu M, Xie X. Photoswitchable Temperature Nanosensors Based on the Chemical Kinetics of Photochromic Naphthopyran for Live Cell Imaging. Anal Chem 2024; 96:4605-4611. [PMID: 38457774 DOI: 10.1021/acs.analchem.3c05568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/10/2024]
Abstract
Microscopic temperature imaging holds significant importance in various fields, particularly in the development of nanomaterials for photothermal therapy (PTT). In this study, we present an analytical method to probe cellular temperature based on chemical kinetics and additional luminescence quenching by photoswitchable naphthopyrans. Taking advantage of the rapid ring-closing reaction of naphthopyran, temperature sensing was realized with a linear relationship between the logarithmic decay time constant (ln τ) and the reciprocal temperature (T-1). To create luminescent temperature nanosensors, we harnessed the ability of ring-opened naphthopyran to quench the luminescence of a semiconducting polymer, resulting in a diverse array of probes. Structural modifications on the naphthopyran also provided a way to fine-tune the sensitivity and response window of the nanosensors. The method allowed cellular temperature imaging on a cost-effective fluorescence microscopic setup. As an application, the temperature increase induced by gold nanorods (AuNRs) in cell lysosomes was successfully monitored, laying the foundation for a new class of photoswitchable nanosensors with promising biological applications.
Collapse
Affiliation(s)
- Yu Cheng
- Department of Chemistry, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Jianhong Wu
- Academy for Advanced Interdisciplinary Studies, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Yunxin Cui
- Department of Chemistry, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Jingying Zhai
- Academy for Advanced Interdisciplinary Studies, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Minghui Wu
- Department of Chemistry, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Xiaojiang Xie
- Department of Chemistry, Southern University of Science and Technology, Shenzhen, 518055, China
| |
Collapse
|
7
|
Gonçalves JM, Bastos ARN, Ribeiro SJL, Carlos LD, Longo RL, Caiut JMA, Ferreira RAS. Thermal properties of nanofluids using hydrophilic and hydrophobic LiYF 4:Yb/Er upconverting nanoparticles. NANOSCALE ADVANCES 2024; 6:1486-1496. [PMID: 38419868 PMCID: PMC10898443 DOI: 10.1039/d3na01114c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Accepted: 01/26/2024] [Indexed: 03/02/2024]
Abstract
Luminescent nanoparticles have shown great potential for thermal sensing in bio-applications. Nonetheless, these materials lack water dispersibility that can be overcome by modifying their surface properties with water dispersible molecules such as cysteine. Herein, we employ LiYF4:Er3+/Yb3+ upconverting nanoparticles (UCNPs) capped with oleate or modified with cysteine dispersed in cyclohexane or in water, respectively, as thermal probes. Upconversion emission was used to sense temperature with a relative thermal sensitivity of ∼1.24% K-1 (at 300 K) and a temperature uncertainty of 0.8 K for the oleate capped and of 0.5 K for cysteine modified NPs. To study the effect of the cysteine modification in the heat transfer processes, the thermal conductivity of the nanofluids was determined, yielding 0.123(6) W m-1 K-1 for the oleate capped UCNPs dispersed in cyclohexane and 0.50(7) W m-1 K-1 for the cysteine modified UCNPs dispersed in water. Moreover, through the heating curves, the nanofluids' thermal resistances were estimated, showing that the cysteine modification partially prevents heat transfer.
Collapse
Affiliation(s)
- João M Gonçalves
- Department of Physics, CICECO - Aveiro Institute of Materials, University of Aveiro Aveiro 3810-193 Portugal
- Department of Chemistry, Faculdade de Filosofia, Ciências e Letras, University of São Paulo Ribeirão Preto 14040-900 Brazil
| | - Ana R N Bastos
- Department of Physics, CICECO - Aveiro Institute of Materials, University of Aveiro Aveiro 3810-193 Portugal
| | - Sidney J L Ribeiro
- Institute of Chemistry, Universidade Estadual Paulista «Júlio de Mesquisa Filho» Araraquara 14800-060 Brazil
| | - L D Carlos
- Department of Physics, CICECO - Aveiro Institute of Materials, University of Aveiro Aveiro 3810-193 Portugal
| | - Ricardo L Longo
- Departamento de Química Fundamental, Universidade Federal de Pernambuco Recife PE 50740-540 Brazil
| | - José Maurício A Caiut
- Department of Chemistry, Faculdade de Filosofia, Ciências e Letras, University of São Paulo Ribeirão Preto 14040-900 Brazil
| | - Rute A S Ferreira
- Department of Physics, CICECO - Aveiro Institute of Materials, University of Aveiro Aveiro 3810-193 Portugal
| |
Collapse
|
8
|
Terzioglu M, Veeroja K, Montonen T, Ihalainen TO, Salminen TS, Bénit P, Rustin P, Chang YT, Nagai T, Jacobs HT. Mitochondrial temperature homeostasis resists external metabolic stresses. eLife 2023; 12:RP89232. [PMID: 38079477 PMCID: PMC10712956 DOI: 10.7554/elife.89232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2023] Open
Abstract
Based on studies with a fluorescent reporter dye, Mito Thermo Yellow (MTY), and the genetically encoded gTEMP ratiometric fluorescent temperature indicator targeted to mitochondria, the temperature of active mitochondria in four mammalian and one insect cell line was estimated to be up to 15°C above that of the external environment to which the cells were exposed. High mitochondrial temperature was maintained in the face of a variety of metabolic stresses, including substrate starvation or modification, decreased ATP demand due to inhibition of cytosolic protein synthesis, inhibition of the mitochondrial adenine nucleotide transporter and, if an auxiliary pathway for electron transfer was available via the alternative oxidase, even respiratory poisons acting downstream of oxidative phosphorylation (OXPHOS) complex I. We propose that the high temperature of active mitochondria is an inescapable consequence of the biochemistry of OXPHOS and is homeostatically maintained as a primary feature of mitochondrial metabolism.
Collapse
Affiliation(s)
- Mügen Terzioglu
- Faculty of Medicine and Health Technology, Tampere UniversityTampereFinland
| | - Kristo Veeroja
- Faculty of Medicine and Health Technology, Tampere UniversityTampereFinland
| | - Toni Montonen
- Faculty of Medicine and Health Technology, Tampere UniversityTampereFinland
| | - Teemu O Ihalainen
- Faculty of Medicine and Health Technology, Tampere UniversityTampereFinland
| | - Tiina S Salminen
- Faculty of Medicine and Health Technology, Tampere UniversityTampereFinland
| | - Paule Bénit
- Université Paris Cité, Inserm, Maladies Neurodéveloppementales et NeurovasculairesParisFrance
| | - Pierre Rustin
- Université Paris Cité, Inserm, Maladies Neurodéveloppementales et NeurovasculairesParisFrance
| | - Young-Tae Chang
- SANKEN (The Institute of Scientific and Industrial Research), Osaka UniversityIbarakiJapan
| | | | - Howard T Jacobs
- Faculty of Medicine and Health Technology, Tampere UniversityTampereFinland
- Department of Environment and Genetics, La Trobe UniversityMelbourneAustralia
| |
Collapse
|
9
|
Kruglov AG, Romshin AM, Nikiforova AB, Plotnikova A, Vlasov II. Warm Cells, Hot Mitochondria: Achievements and Problems of Ultralocal Thermometry. Int J Mol Sci 2023; 24:16955. [PMID: 38069275 PMCID: PMC10707128 DOI: 10.3390/ijms242316955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 11/27/2023] [Accepted: 11/28/2023] [Indexed: 12/18/2023] Open
Abstract
Temperature is a crucial regulator of the rate and direction of biochemical reactions and cell processes. The recent data indicating the presence of local thermal gradients associated with the sites of high-rate thermogenesis, on the one hand, demonstrate the possibility for the existence of "thermal signaling" in a cell and, on the other, are criticized on the basis of thermodynamic calculations and models. Here, we review the main thermometric techniques and sensors developed for the determination of temperature inside living cells and diverse intracellular compartments. A comparative analysis is conducted of the results obtained using these methods for the cytosol, nucleus, endo-/sarcoplasmic reticulum, and mitochondria, as well as their biological consistency. Special attention is given to the limitations, possible sources of errors and ambiguities of the sensor's responses. The issue of biological temperature limits in cells and organelles is considered. It is concluded that the elaboration of experimental protocols for ultralocal temperature measurements that take into account both the characteristics of biological systems, as well as the properties and limitations of each type of sensor is of critical importance for the generation of reliable results and further progress in this field.
Collapse
Affiliation(s)
- Alexey G. Kruglov
- Institute of Theoretical and Experimental Biophysics of the Russian Academy of Sciences, 142290 Pushchino, Russia;
| | - Alexey M. Romshin
- Prokhorov General Physics Institute of the Russian Academy of Sciences, 119991 Moscow, Russia;
| | - Anna B. Nikiforova
- Institute of Theoretical and Experimental Biophysics of the Russian Academy of Sciences, 142290 Pushchino, Russia;
| | - Arina Plotnikova
- Institute for Physics and Engineering in Biomedicine, National Research Nuclear University MEPhI (Moscow Engineering Physics Institute MEPhI), 115409 Moscow, Russia;
| | - Igor I. Vlasov
- Prokhorov General Physics Institute of the Russian Academy of Sciences, 119991 Moscow, Russia;
| |
Collapse
|
10
|
Đačanin Far L, Dramićanin MD. Luminescence Thermometry with Nanoparticles: A Review. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2904. [PMID: 37947749 PMCID: PMC10647651 DOI: 10.3390/nano13212904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 10/31/2023] [Accepted: 11/02/2023] [Indexed: 11/12/2023]
Abstract
Luminescence thermometry has emerged as a very versatile optical technique for remote temperature measurements, exhibiting a wide range of applicability spanning from cryogenic temperatures to 2000 K. This technology has found extensive utilization across many disciplines. In the last thirty years, there has been significant growth in the field of luminous thermometry. This growth has been accompanied by the development of temperature read-out procedures, the creation of luminescent materials for very sensitive temperature probes, and advancements in theoretical understanding. This review article primarily centers on luminescent nanoparticles employed in the field of luminescence thermometry. In this paper, we provide a comprehensive survey of the recent literature pertaining to the utilization of lanthanide and transition metal nanophosphors, semiconductor quantum dots, polymer nanoparticles, carbon dots, and nanodiamonds for luminescence thermometry. In addition, we engage in a discussion regarding the benefits and limitations of nanoparticles in comparison with conventional, microsized probes for their application in luminescent thermometry.
Collapse
Affiliation(s)
| | - Miroslav D. Dramićanin
- Centre of Excellence for Photoconversion, Vinča Institute of Nuclear Sciences—National Institute of the Republic of Serbia, University of Belgrade, P.O. Box 522, 11001 Belgrade, Serbia;
| |
Collapse
|
11
|
Correia SFH, Fu L, Dias LMS, Pereira RFP, de Zea Bermudez V, André PS, Ferreira RAS. An autonomous power temperature sensor based on window-integrated transparent PV using sustainable luminescent carbon dots. NANOSCALE ADVANCES 2023; 5:3428-3438. [PMID: 37383075 PMCID: PMC10295119 DOI: 10.1039/d3na00136a] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 04/06/2023] [Indexed: 06/30/2023]
Abstract
The energy efficiency of buildings can be significantly improved through the use of renewable energy sources. Luminescent solar concentrators (LSCs) appear to be a solution for integrating photovoltaic (PV) devices into the structure of buildings (windows, for instance) to enable low-voltage devices to be powered. Here, we present transparent planar and cylindrical LSCs based on carbon dots in an aqueous solution and dispersed in organic-inorganic hybrid matrices, which present photoluminescent quantum yield values up to 82%, facilitating an effective solar photon conversion. These LSCs showed the potencial for being incorporated as building windows due to an average light transmittance of up to ∼91% and color rendering index of up to 97, with optical and power conversion efficiency values of 5.4 ± 0.1% and 0.18 ± 0.01%, respectively. In addition, the fabricated devices showed temperature sensing ability enabling the fabrication of an autonomous power mobile temperature sensor. Two independent thermometric parameters were established based on the emission and the electrical power generated by the LSC-PV system, which could both be accessed by a mobile phone, enabling mobile optical sensing through multiparametric thermal reading with relative sensitivity values up to 1.0% °C-1, making real-time mobile temperature sensing accessible to all users.
Collapse
Affiliation(s)
- Sandra F H Correia
- Instituto de Telecomunicações and University of Aveiro, Campus Universitário de Santiago 3810-193 Aveiro Portugal
| | - Lianshe Fu
- Department of Physics and CICECO - Aveiro Institute of Materials, University of Aveiro 3810-193 Aveiro Portugal
| | - Lília M S Dias
- Department of Physics and CICECO - Aveiro Institute of Materials, University of Aveiro 3810-193 Aveiro Portugal
- Department of Electrical and Computer Engineering and Instituto de Telecomunicações, Instituto Superior Técnico, University of Lisbon 1049-001 Lisbon Portugal
| | - Rui F P Pereira
- Chemistry Center and Chemistry Department, University of Minho 4710-057 Braga Portugal
| | - V de Zea Bermudez
- Chemistry Department and CQ-VR, University of Trás-os-Montes e Alto Douro 5000-801 Vila Real Portugal
| | - Paulo S André
- Department of Electrical and Computer Engineering and Instituto de Telecomunicações, Instituto Superior Técnico, University of Lisbon 1049-001 Lisbon Portugal
| | - Rute A S Ferreira
- Department of Physics and CICECO - Aveiro Institute of Materials, University of Aveiro 3810-193 Aveiro Portugal
| |
Collapse
|
12
|
Sorenson AE, Schaeffer PM. Real-Time Temperature Sensing Using a Ratiometric Dual Fluorescent Protein Biosensor. BIOSENSORS 2023; 13:338. [PMID: 36979550 PMCID: PMC10046200 DOI: 10.3390/bios13030338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 02/27/2023] [Accepted: 03/02/2023] [Indexed: 06/18/2023]
Abstract
Accurate temperature control within biological and chemical reaction samples and instrument calibration are essential to the diagnostic, pharmaceutical and chemical industries. This is particularly challenging for microlitre-scale reactions typically used in real-time PCR applications and differential scanning fluorometry. Here, we describe the development of a simple, inexpensive ratiometric dual fluorescent protein temperature biosensor (DFPTB). A combination of cycle three green fluorescent protein and a monomeric red fluorescent protein enabled the quantification of relative temperature changes and the identification of temperature discrepancies across a wide temperature range of 4-70 °C. The maximal sensitivity of 6.7% °C-1 and precision of 0.1 °C were achieved in a biologically relevant temperature range of 25-42 °C in standard phosphate-buffered saline conditions at a pH of 7.2. Good temperature sensitivity was achieved in a variety of biological buffers and pH ranging from 4.8 to 9.1. The DFPTB can be used in either purified or mixed bacteria-encapsulated formats, paving the way for in vitro and in vivo applications for topologically precise temperature measurements.
Collapse
|
13
|
How hot can mitochondria be? Incubation at temperatures above 43 °C induces the degradation of respiratory complexes and supercomplexes in intact cells and isolated mitochondria. Mitochondrion 2023; 69:83-94. [PMID: 36764502 DOI: 10.1016/j.mito.2023.02.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 01/25/2023] [Accepted: 02/04/2023] [Indexed: 02/11/2023]
Abstract
Mitochondrial function generates an important fraction of the heat that contributes to cellular and organismal temperature maintenance, but the actual values of this parameter reached in the organelles is a matter of debate. The studies addressing this issue have reported divergent results: from detecting in the organelles the same temperature as the cell average or the incubation temperature, to increasing differences of up to 10 degrees above the incubation value. Theoretical calculations based on physical laws exclude the possibility of relevant temperature gradients between mitochondria and their surroundings. These facts have given rise to a conundrum or paradox about hot mitochondria. We have examined by Blue-Native electrophoresis, both in intact cells and in isolated organelles, the stability of respiratory complexes and supercomplexes at different temperatures to obtain information about their tolerance to heat stress. We observe that, upon incubation at values above 43 °C and after relatively short periods, respiratory complexes, and especially complex I and its supercomplexes, are unstable even when the respiratory activity is inhibited. These results support the conclusion that high temperatures (>43 °C) cause damage to mitochondrial structure and function and question the proposal that these organelles can physiologically work at close to 50 °C.
Collapse
|
14
|
Inada N. A Guide to Plant Intracellular Temperature Imaging using Fluorescent Thermometers. PLANT & CELL PHYSIOLOGY 2023; 64:7-18. [PMID: 36039974 DOI: 10.1093/pcp/pcac123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2022] [Revised: 07/06/2022] [Accepted: 08/30/2022] [Indexed: 06/15/2023]
Abstract
All aspects of plant physiology are influenced by temperature. Changes in environmental temperature alter the temperatures of plant tissues and cells, which then affect various cellular activities, such as gene expression, protein stability and enzyme activities. In turn, changes in cellular activities, which are associated with either exothermic or endothermic reactions, can change the local temperature in cells and tissues. In the past 10 years, a number of fluorescent probes that detect temperature and enable intracellular temperature imaging have been reported. Intracellular temperature imaging has revealed that there is a temperature difference >1°C inside cells and that the treatment of cells with mitochondrial uncoupler or ionomycin can cause more than a 1°C intracellular temperature increase in mammalian cultured cells. Thermogenesis mechanisms in brown adipocytes have been revealed with the aid of intracellular temperature imaging. While there have been no reports on plant intracellular temperature imaging thus far, intracellular temperature imaging is expected to provide a new way to analyze the mechanisms underlying the various activities of plant cells. In this review, I will first summarize the recent progress in the development of fluorescent thermometers and their biological applications. I will then discuss the selection of fluorescent thermometers and experimental setup for the adaptation of intracellular temperature imaging to plant cells. Finally, possible applications of intracellular temperature imaging to investigate plant cell functions will be discussed.
Collapse
Affiliation(s)
- Noriko Inada
- Graduate School of Life and Environmental Sciences, Osaka Prefecture University, 1-1 Gakuen-cho, Naka-ku, Sakai-shi, Osaka, 599-8531 Japan
- School of Agriculture, Osaka Metropolitan University, 1-1 Gakuen-cho, Naka-ku, Sakai-shi, Osaka, 599-8531 Japan
| |
Collapse
|
15
|
Cheng Y, Ma X, Zhai J, Xie X. Visible light responsive photoacids for subcellular pH and temperature correlated fluorescence sensing. Chem Commun (Camb) 2023; 59:1805-1808. [PMID: 36722768 DOI: 10.1039/d2cc06816h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Liao's photoacids (PAs) are a well-known type of visible light-responsive photoswitches. Here, taking advantage of the temperature-dependent thermal relaxation from the ring-closed to the ring-opened forms, PAs are proposed for the first time as a fluorescent temperature sensor in cells. The logarithmic lifetime (ln τ) of the ring-closed spiro-form exhibited an excellent linear response to the reciprocal of the temperature. In addition, the fluorescent ring-opened PAs were able to highlight lysosomes and responded to lysosomal pH changes. These properties made the PAs promising fluorescent probes in the sensing of subcellular pH and temperature.
Collapse
Affiliation(s)
- Yu Cheng
- Department of Chemistry, Southern University of Science and Technology, Shenzhen, 518055, China. .,Research Center for Chemical Biology and Omics Analysis, School of Science, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Xueqing Ma
- Department of Chemistry, Southern University of Science and Technology, Shenzhen, 518055, China. .,Research Center for Chemical Biology and Omics Analysis, School of Science, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Jingying Zhai
- Academy for Advanced Interdisciplinary Studies, Southern University of Science and Technology, Shenzhen, 518055, China.,Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Xiaojiang Xie
- Department of Chemistry, Southern University of Science and Technology, Shenzhen, 518055, China. .,Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, 518055, China.,Research Center for Chemical Biology and Omics Analysis, School of Science, Southern University of Science and Technology, Shenzhen, 518055, China
| |
Collapse
|
16
|
Romshin AM, Osypov AA, Popova IY, Zeeb VE, Sinogeykin AG, Vlasov II. Heat Release by Isolated Mouse Brain Mitochondria Detected with Diamond Thermometer. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 13:98. [PMID: 36616008 PMCID: PMC9823591 DOI: 10.3390/nano13010098] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 12/15/2022] [Accepted: 12/21/2022] [Indexed: 06/17/2023]
Abstract
The production of heat by mitochondria is critical for maintaining body temperature, regulating metabolic rate, and preventing oxidative damage to mitochondria and cells. Until the present, mitochondrial heat production has been characterized only by methods based on fluorescent probes, which are sensitive to environmental variations (viscosity, pH, ionic strength, quenching, etc.). Here, for the first time, the heat release of isolated mitochondria was unambiguously measured by a diamond thermometer (DT), which is absolutely indifferent to external non-thermal parameters. We show that during total uncoupling of transmembrane potential by CCCP application, the temperature near the mitochondria rises by 4-22 °C above the ambient temperature with an absolute maximum of 45 °C. Such a broad variation in the temperature response is associated with the heterogeneity of the mitochondria themselves as well as their aggregations in the isolated suspension. Spontaneous temperature bursts with comparable amplitude were also detected prior to CCCP application, which may reflect involvement of some mitochondria to ATP synthesis or membrane potential leaking to avoid hyperproduction of reactive oxygen species. The results obtained with the diamond temperature sensor shed light on the "hot mitochondria" paradox.
Collapse
Affiliation(s)
- Alexey M. Romshin
- Prokhorov General Physics Institute of the Russian Academy of Sciences, 119991 Moscow, Russia
| | - Alexander A. Osypov
- Institute of Theoretical and Experimental Biophysics of the Russian Academy of Sciences, 142292 Moscow, Russia
- Institute of Higher Nervous Activity and Neurophysiology of the Russian Academy of Sciences, 117485 Moscow, Russia
| | - Irina Yu. Popova
- Institute of Theoretical and Experimental Biophysics of the Russian Academy of Sciences, 142292 Moscow, Russia
| | - Vadim E. Zeeb
- Institute of Theoretical and Experimental Biophysics of the Russian Academy of Sciences, 142292 Moscow, Russia
| | | | - Igor I. Vlasov
- Prokhorov General Physics Institute of the Russian Academy of Sciences, 119991 Moscow, Russia
| |
Collapse
|
17
|
Pittman M, Ali AM, Chen Y. How sticky? How tight? How hot? Imaging probes for fluid viscosity, membrane tension and temperature measurements at the cellular level. Int J Biochem Cell Biol 2022; 153:106329. [PMID: 36336304 PMCID: PMC10148659 DOI: 10.1016/j.biocel.2022.106329] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 10/22/2022] [Accepted: 10/31/2022] [Indexed: 11/06/2022]
Abstract
We review the progress made in imaging probes for three important physical parameters: viscosity, membrane tension, and temperature, all of which play important roles in many cellular processes. Recent evidences showed that cell migration speed can be modulated by extracellular fluid viscosity; membrane tension contributes to the regulation of cell motility, exo-/endo-cytosis, and cell spread area; and temperature affects neural activity and adipocyte differentiation. We discuss the techniques implementing imaging-based probes to measure viscosity, membrane tension, and temperature at subcellular resolution dynamically. The merits and shortcomings of each technique are examined, and the future applications of the recently developed techniques are also explored.
Collapse
Affiliation(s)
- Matthew Pittman
- Department of Mechanical Engineering, Johns Hopkins University, MD, USA; Center for Cell Dynamics, Johns Hopkins University, MD, USA; Institute for NanoBio Technology, Johns Hopkins University, MD, USA
| | - Abdulla M Ali
- Center for Cell Dynamics, Johns Hopkins University, MD, USA; Institute for NanoBio Technology, Johns Hopkins University, MD, USA; T.C. Jenkins Department of Biophysics, Johns Hopkins University, MD, USA
| | - Yun Chen
- Department of Mechanical Engineering, Johns Hopkins University, MD, USA; Center for Cell Dynamics, Johns Hopkins University, MD, USA; Institute for NanoBio Technology, Johns Hopkins University, MD, USA.
| |
Collapse
|
18
|
Lu K, Wazawa T, Sakamoto J, Vu CQ, Nakano M, Kamei Y, Nagai T. Intracellular Heat Transfer and Thermal Property Revealed by Kilohertz Temperature Imaging with a Genetically Encoded Nanothermometer. NANO LETTERS 2022; 22:5698-5707. [PMID: 35792763 PMCID: PMC9335883 DOI: 10.1021/acs.nanolett.2c00608] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Despite improved sensitivity of nanothermometers, direct observation of heat transport inside single cells has remained challenging for the lack of high-speed temperature imaging techniques. Here, we identified insufficient temperature resolution under short signal integration time and slow sensor kinetics as two major bottlenecks. To overcome the limitations, we developed B-gTEMP, a nanothermometer based on the tandem fusion of mNeonGreen and tdTomato fluorescent proteins. We visualized the propagation of heat inside intracellular space by tracking the temporal variation of local temperature at a time resolution of 155 μs and a temperature resolution 0.042 °C. By comparing the fast in situ temperature dynamics with computer-simulated heat diffusion, we estimated the thermal diffusivity of live HeLa cells. The present thermal diffusivity in cells was about 1/5.3 of that of water and much smaller than the values reported for bulk tissues, which may account for observations of heterogeneous intracellular temperature distributions.
Collapse
Affiliation(s)
- Kai Lu
- SANKEN
(The Institute of Scientific and Industrial Research), Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047, Japan
| | - Tetsuichi Wazawa
- SANKEN
(The Institute of Scientific and Industrial Research), Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047, Japan
| | - Joe Sakamoto
- National
Institute for Basic Biology, Nishigonaka 38, Myodaiji, Okazaki, Aichi 444-8585, Japan
| | - Cong Quang Vu
- SANKEN
(The Institute of Scientific and Industrial Research), Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047, Japan
- Graduate
School of Frontier Biosciences, Osaka University, 1-3 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Masahiro Nakano
- SANKEN
(The Institute of Scientific and Industrial Research), Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047, Japan
| | - Yasuhiro Kamei
- National
Institute for Basic Biology, Nishigonaka 38, Myodaiji, Okazaki, Aichi 444-8585, Japan
| | - Takeharu Nagai
- SANKEN
(The Institute of Scientific and Industrial Research), Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047, Japan
- Graduate
School of Frontier Biosciences, Osaka University, 1-3 Yamadaoka, Suita, Osaka 565-0871, Japan
| |
Collapse
|
19
|
El-Gammal Z, Nasr MA, Elmehrath AO, Salah RA, Saad SM, El-Badri N. Regulation of mitochondrial temperature in health and disease. Pflugers Arch 2022; 474:1043-1051. [PMID: 35780250 PMCID: PMC9492600 DOI: 10.1007/s00424-022-02719-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 06/15/2022] [Indexed: 11/30/2022]
Abstract
Mitochondrial temperature is produced by various metabolic processes inside the mitochondria, particularly oxidative phosphorylation. It was recently reported that mitochondria could normally operate at high temperatures that can reach 50℃. The aim of this review is to identify mitochondrial temperature differences between normal cells and cancer cells. Herein, we discussed the different types of mitochondrial thermosensors and their advantages and disadvantages. We reviewed the studies assessing the mitochondrial temperature in cancer cells and normal cells. We shed the light on the factors involved in maintaining the mitochondrial temperature of normal cells compared to cancer cells.
Collapse
Affiliation(s)
- Zaynab El-Gammal
- Center of Excellence for Stem Cells and Regenerative Medicine (CESC), Zewail City of Science and Technology, Cairo, Egypt.,Egypt Center for Research and Regenerative Medicine, Cairo, Egypt
| | - Mohamed A Nasr
- Center of Excellence for Stem Cells and Regenerative Medicine (CESC), Zewail City of Science and Technology, Cairo, Egypt
| | - Ahmed O Elmehrath
- Center of Excellence for Stem Cells and Regenerative Medicine (CESC), Zewail City of Science and Technology, Cairo, Egypt.,Faculty of Medicine, Cairo University, Cairo, Egypt
| | - Radwa A Salah
- Center of Excellence for Stem Cells and Regenerative Medicine (CESC), Zewail City of Science and Technology, Cairo, Egypt
| | - Shams M Saad
- Center of Excellence for Stem Cells and Regenerative Medicine (CESC), Zewail City of Science and Technology, Cairo, Egypt
| | - Nagwa El-Badri
- Center of Excellence for Stem Cells and Regenerative Medicine (CESC), Zewail City of Science and Technology, Cairo, Egypt.
| |
Collapse
|
20
|
Correia SF, Bastos AR, Martins M, Macário IP, Veloso T, Pereira JL, Coutinho JA, Ventura SP, André PS, Ferreira RA. Bio-Based Solar Energy Harvesting for Onsite Mobile Optical Temperature Sensing in Smart Cities. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2104801. [PMID: 35347889 PMCID: PMC9189672 DOI: 10.1002/advs.202104801] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 03/02/2022] [Indexed: 05/29/2023]
Abstract
The Internet of Things (IoT) fosters the development of smart city systems for sustainable living and increases comfort for people. One of the current challenges for sustainable buildings is the optimization of energy management. Temperature monitoring in buildings is of prime importance, as heating account for a great part of the total energy consumption. Here, a solar optical temperature sensor is presented with a thermal sensitivity of up to 1.23% °C-1 based on sustainable aqueous solutions of enhanced green fluorescent protein and C-phycocyanin from biological feedstocks. These photonic sensors are presented under the configuration of luminescent solar concentrators widely proposed as a solution to integrate energy-generating devices in buildings, as windows or façades. The developed mobile sensor is inserted in IoT context through the development of a self-powered system able to measure, record, and send data to a user-friendly website.
Collapse
Affiliation(s)
- Sandra F.H. Correia
- Department of Physics, CICECO – Aveiro Institute of MaterialsUniversity of AveiroAveiro3810‐193Portugal
- Instituto de Telecomunicações and University of AveiroCampus Universitário de SantiagoAveiro3810‐193Portugal
| | - Ana R.N. Bastos
- Department of Physics, CICECO – Aveiro Institute of MaterialsUniversity of AveiroAveiro3810‐193Portugal
| | - Margarida Martins
- Department of Chemistry, CICECO – Aveiro Institute of MaterialsUniversity of AveiroAveiro3810‐193Portugal
| | - Inês P.E. Macário
- Department of Chemistry, CICECO – Aveiro Institute of MaterialsUniversity of AveiroAveiro3810‐193Portugal
- Department of Biology, CESAMUniversity of AveiroAveiro3810‐193Portugal
| | - Telma Veloso
- Department of Chemistry, CICECO – Aveiro Institute of MaterialsUniversity of AveiroAveiro3810‐193Portugal
- Department of Biology, CESAMUniversity of AveiroAveiro3810‐193Portugal
| | - Joana L. Pereira
- Department of Biology, CESAMUniversity of AveiroAveiro3810‐193Portugal
| | - João A.P. Coutinho
- Department of Chemistry, CICECO – Aveiro Institute of MaterialsUniversity of AveiroAveiro3810‐193Portugal
| | - Sónia P.M. Ventura
- Department of Chemistry, CICECO – Aveiro Institute of MaterialsUniversity of AveiroAveiro3810‐193Portugal
| | - Paulo S. André
- Department of Electrical and Computer Engineering, Instituto de TelecomunicaçõesInstituto Superior TécnicoUniversidade de LisboaLisbon1049‐001Portugal
| | - Rute A.S. Ferreira
- Department of Physics, CICECO – Aveiro Institute of MaterialsUniversity of AveiroAveiro3810‐193Portugal
| |
Collapse
|
21
|
Losa J, Leupold S, Alonso‐Martinez D, Vainikka P, Thallmair S, Tych KM, Marrink SJ, Heinemann M. Perspective: a stirring role for metabolism in cells. Mol Syst Biol 2022; 18:e10822. [PMID: 35362256 PMCID: PMC8972047 DOI: 10.15252/msb.202110822] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 03/05/2022] [Accepted: 03/09/2022] [Indexed: 11/24/2022] Open
Abstract
Based on recent findings indicating that metabolism might be governed by a limit on the rate at which cells can dissipate Gibbs energy, in this Perspective, we propose a new mechanism of how metabolic activity could globally regulate biomolecular processes in a cell. Specifically, we postulate that Gibbs energy released in metabolic reactions is used to perform work, allowing enzymes to self-propel or to break free from supramolecular structures. This catalysis-induced enzyme movement will result in increased intracellular motion, which in turn can compromise biomolecular functions. Once the increased intracellular motion has a detrimental effect on regulatory mechanisms, this will establish a feedback mechanism on metabolic activity, and result in the observed thermodynamic limit. While this proposed explanation for the identified upper rate limit on cellular Gibbs energy dissipation rate awaits experimental validation, it offers an intriguing perspective of how metabolic activity can globally affect biomolecular functions and will hopefully spark new research.
Collapse
Affiliation(s)
- José Losa
- Molecular Systems BiologyGroningen Biomolecular Sciences and Biotechnology InstituteUniversity of GroningenGroningenThe Netherlands
| | - Simeon Leupold
- Molecular Systems BiologyGroningen Biomolecular Sciences and Biotechnology InstituteUniversity of GroningenGroningenThe Netherlands
| | - Diego Alonso‐Martinez
- Molecular Systems BiologyGroningen Biomolecular Sciences and Biotechnology InstituteUniversity of GroningenGroningenThe Netherlands
| | - Petteri Vainikka
- Molecular DynamicsGroningen Biomolecular Sciences and Biotechnology InstituteUniversity of GroningenGroningenThe Netherlands
| | - Sebastian Thallmair
- Molecular DynamicsGroningen Biomolecular Sciences and Biotechnology InstituteUniversity of GroningenGroningenThe Netherlands
- Present address:
Frankfurt Institute for Advanced StudiesFrankfurt am MainGermany
| | - Katarzyna M Tych
- Chemical BiologyGroningen Biomolecular Sciences and Biotechnology InstituteUniversity of GroningenGroningenThe Netherlands
| | - Siewert J Marrink
- Molecular DynamicsGroningen Biomolecular Sciences and Biotechnology InstituteUniversity of GroningenGroningenThe Netherlands
| | - Matthias Heinemann
- Molecular Systems BiologyGroningen Biomolecular Sciences and Biotechnology InstituteUniversity of GroningenGroningenThe Netherlands
| |
Collapse
|
22
|
Rodríguez-Sevilla P, Thompson SA, Jaque D. Multichannel Fluorescence Microscopy: Advantages of Going beyond a Single Emission. ADVANCED NANOBIOMED RESEARCH 2022. [DOI: 10.1002/anbr.202100084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Affiliation(s)
- Paloma Rodríguez-Sevilla
- Nanomaterials for Bioimaging Group (NanoBIG) Departamento de Física de Materiales Universidad Autónoma de Madrid C/Francisco Tomás y Valiente 7 Madrid 28049 Spain
| | - Sebastian A. Thompson
- Madrid Institute for Advanced Studies in Nanoscience (IMDEA Nanociencia) C/Faraday 9 Madrid 28049 Spain
- Nanobiotechnology Unit Associated to the National Center for Biotechnology (CNB-CSIC-IMDEA) Madrid 28049 Spain
| | - Daniel Jaque
- Nanomaterials for Bioimaging Group (NanoBIG) Departamento de Física de Materiales Universidad Autónoma de Madrid C/Francisco Tomás y Valiente 7 Madrid 28049 Spain
- Instituto Ramón y Cajal de Investigación Sanitaria Hospital Ramón y Cajal Ctra. Colmenar km. 9,100 Madrid 28034 Spain
| |
Collapse
|
23
|
Opto-thermal technologies for microscopic analysis of cellular temperature-sensing systems. Biophys Rev 2021; 14:41-54. [PMID: 35340595 PMCID: PMC8921355 DOI: 10.1007/s12551-021-00854-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Accepted: 10/12/2021] [Indexed: 12/15/2022] Open
Abstract
AbstractCould enzymatic activities and their cooperative functions act as cellular temperature-sensing systems? This review introduces recent opto-thermal technologies for microscopic analyses of various types of cellular temperature-sensing system. Optical microheating technologies have been developed for local and rapid temperature manipulations at the cellular level. Advanced luminescent thermometers visualize the dynamics of cellular local temperature in space and time during microheating. An optical heater and thermometer can be combined into one smart nanomaterial that demonstrates hybrid function. These technologies have revealed a variety of cellular responses to spatial and temporal changes in temperature. Spatial temperature gradients cause asymmetric deformations during mitosis and neurite outgrowth. Rapid changes in temperature causes imbalance of intracellular Ca2+ homeostasis and membrane potential. Among those responses, heat-induced muscle contractions are highlighted. It is also demonstrated that the short-term heating hyperactivates molecular motors to exceed their maximal activities at optimal temperatures. We discuss future prospects for opto-thermal manipulation of cellular functions and contributions to obtain a deeper understanding of the mechanisms of cellular temperature-sensing systems.
Collapse
|
24
|
Ovejero JG, Armenia I, Serantes D, Veintemillas-Verdaguer S, Zeballos N, López-Gallego F, Grüttner C, de la Fuente JM, Puerto Morales MD, Grazu V. Selective Magnetic Nanoheating: Combining Iron Oxide Nanoparticles for Multi-Hot-Spot Induction and Sequential Regulation. NANO LETTERS 2021; 21:7213-7220. [PMID: 34410726 PMCID: PMC8431726 DOI: 10.1021/acs.nanolett.1c02178] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 08/11/2021] [Indexed: 05/11/2023]
Abstract
The contactless heating capacity of magnetic nanoparticles (MNPs) has been exploited in fields such as hyperthermia cancer therapy, catalysis, and enzymatic thermal regulation. Herein, we propose an advanced technology to generate multiple local temperatures in a single-pot reactor by exploiting the unique nanoheating features of iron oxide MNPs exposed to alternating magnetic fields (AMFs). The heating power of the MNPs depends on their magnetic features but also on the intensity and frequency conditions of the AMF. Using a mixture of diluted colloids of MNPs we were able to generate a multi-hot-spot reactor in which each population of MNPs can be selectively activated by adjusting the AMF conditions. The maximum temperature reached at the surface of each MNP was registered using independent fluorescent thermometers that mimic the molecular link between enzymes and MNPs. This technology paves the path for the implementation of a selective regulation of multienzymatic reactions.
Collapse
Affiliation(s)
- Jesus G. Ovejero
- Institute
of Materials Science of Madrid (ICMM-CSIC), Sor Juana Inés de la Cruz
3, 28049 Madrid, Spain
| | - Ilaria Armenia
- BioNanoSurf
Group, Aragon Nanoscience and Materials Institute (INMA-CSIC-UNIZAR),
Edificio I+D, Mariano
Esquillor Gómez, 50018 Zaragoza, Spain
| | - David Serantes
- Applied
Physics Department and Instituto de Investigacións Tecnolóxicas, Universidade de Santiago de Compostela, 15782 Santiago
de Compostela, Spain
| | | | - Nicoll Zeballos
- Heterogeneous
Biocatalysis Laboratory, Center for Cooperative
Research in Biomaterials (CIC biomaGUNE), Basque Research and Technology
Alliance, Paseo de Miramón
194, 20014 Donostia-San
Sebastián, Spain
- IKERBASQUE,
Basque Foundation for Science, María Díaz de Haro 3, 48013 Bilbao, Spain
| | - Fernando López-Gallego
- Heterogeneous
Biocatalysis Laboratory, Center for Cooperative
Research in Biomaterials (CIC biomaGUNE), Basque Research and Technology
Alliance, Paseo de Miramón
194, 20014 Donostia-San
Sebastián, Spain
- IKERBASQUE,
Basque Foundation for Science, María Díaz de Haro 3, 48013 Bilbao, Spain
| | - Cordula Grüttner
- Micromod,
Partikeltechnologie GmbH, Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany
| | - Jesús M. de la Fuente
- BioNanoSurf
Group, Aragon Nanoscience and Materials Institute (INMA-CSIC-UNIZAR),
Edificio I+D, Mariano
Esquillor Gómez, 50018 Zaragoza, Spain
- Centro
de Investigación Biomédica en Red de Bioingeniería,
Biomateriales y Nanomedicina (CIBER-BBN), Avenida Monforte de Lemos, 3-5, 28029 Madrid, Spain
| | - María del Puerto Morales
- Institute
of Materials Science of Madrid (ICMM-CSIC), Sor Juana Inés de la Cruz
3, 28049 Madrid, Spain
| | - Valeria Grazu
- BioNanoSurf
Group, Aragon Nanoscience and Materials Institute (INMA-CSIC-UNIZAR),
Edificio I+D, Mariano
Esquillor Gómez, 50018 Zaragoza, Spain
- Centro
de Investigación Biomédica en Red de Bioingeniería,
Biomateriales y Nanomedicina (CIBER-BBN), Avenida Monforte de Lemos, 3-5, 28029 Madrid, Spain
| |
Collapse
|
25
|
Vu CQ, Fukushima SI, Wazawa T, Nagai T. A highly-sensitive genetically encoded temperature indicator exploiting a temperature-responsive elastin-like polypeptide. Sci Rep 2021; 11:16519. [PMID: 34389773 PMCID: PMC8363741 DOI: 10.1038/s41598-021-96049-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2021] [Accepted: 07/26/2021] [Indexed: 12/02/2022] Open
Abstract
Genetically encoded temperature indicators (GETIs) allow for real-time measurement of subcellular temperature dynamics in live cells. However, GETIs have suffered from poor temperature sensitivity, which may not be sufficient to resolve small heat production from a biological process. Here, we develop a highly-sensitive GETI, denoted as ELP-TEMP, comprised of a temperature-responsive elastin-like polypeptide (ELP) fused with a cyan fluorescent protein (FP), mTurquoise2 (mT), and a yellow FP, mVenus (mV), as the donor and acceptor, respectively, of Förster resonance energy transfer (FRET). At elevated temperatures, the ELP moiety in ELP-TEMP undergoes a phase transition leading to an increase in the FRET efficiency. In HeLa cells, ELP-TEMP responded to the temperature from 33 to 40 °C with a maximum temperature sensitivity of 45.1 ± 8.1%/°C, which was the highest ever temperature sensitivity among hitherto-developed fluorescent nanothermometers. Although ELP-TEMP showed sensitivity not only to temperature but also to macromolecular crowding and self-concentration, we were able to correct the output of ELP-TEMP to achieve accurate temperature measurements at a subcellular resolution. We successfully applied ELP-TEMP to accurately measure temperature changes in cells induced by a local heat spot, even if the temperature difference was as small as < 1 °C, and to visualize heat production from stimulated Ca2+ influx in live HeLa cells induced by a chemical stimulation. Furthermore, we investigated temperatures in the nucleus and cytoplasm of live HeLa cells and found that their temperatures were almost the same within the temperature resolution of our measurement. Our study would contribute to better understanding of cellular temperature dynamics, and ELP-TEMP would be a useful GETI for the investigation of cell thermobiology.
Collapse
Affiliation(s)
- Cong Quang Vu
- Graduate School of Frontier Biosciences, Osaka University, Suita, Osaka, 565-0871, Japan.,SANKEN (The Institute of Scientific and Industrial Research), Osaka University, Ibaraki, Osaka, 567-0047, Japan
| | - Shun-Ichi Fukushima
- SANKEN (The Institute of Scientific and Industrial Research), Osaka University, Ibaraki, Osaka, 567-0047, Japan
| | - Tetsuichi Wazawa
- SANKEN (The Institute of Scientific and Industrial Research), Osaka University, Ibaraki, Osaka, 567-0047, Japan
| | - Takeharu Nagai
- Graduate School of Frontier Biosciences, Osaka University, Suita, Osaka, 565-0871, Japan. .,SANKEN (The Institute of Scientific and Industrial Research), Osaka University, Ibaraki, Osaka, 567-0047, Japan.
| |
Collapse
|
26
|
Morikawa TJ, Nishiyama M, Yoshizawa K, Fujita H, Watanabe TM. Glycine insertion modulates the fluorescence properties of Aequorea victoria green fluorescent protein and its variants in their ambient environment. Biophys Physicobiol 2021; 18:145-158. [PMID: 34178565 PMCID: PMC8214926 DOI: 10.2142/biophysico.bppb-v18.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 04/27/2021] [Indexed: 12/04/2022] Open
Abstract
The green fluorescent protein (GFP) derived from Pacific Ocean jellyfish is an essential tool in biology. GFP-solvent interactions can modulate the fluorescent property of GFP. We previously reported that glycine insertion is an effective mutation in the yellow variant of GFP, yellow fluorescent protein (YFP). Glycine insertion into one of the β-strands comprising the barrel structure distorts its structure, allowing water molecules to invade near the chromophore, enhancing hydrostatic pressure or solution hydrophobicity sensitivity. However, the underlying mechanism of how glycine insertion imparts environmental sensitivity to YFP has not been elucidated yet. To unveil the relationship between fluorescence and β-strand distortion, we investigated the effects of glycine insertion on the dependence of the optical properties of GFP variants named enhanced-GFP (eGFP) and its yellow (eYFP) and cyan (eCFP) variants with respect to pH, temperature, pressure, and hydrophobicity. Our results showed that the quantum yield decreased depending on the number of inserted glycines in all variants, and the dependence on pH, temperature, pressure, and hydrophobicity was altered, indicating the invasion of water molecules into the β-barrel. Peak shifts in the emission spectrum were observed in glycine-inserted eGFP, suggesting a change of the electric state in the excited chromophore. A comparative investigation of the spectral shift among variants under different conditions demonstrated that glycine insertion rearranged the hydrogen bond network between His148 and the chromophore. The present results provide important insights for further understanding the fluorescence mechanism in GFPs and suggest that glycine insertion could be a potent approach for investigating the relationship between water molecules and the intra-protein chromophore.
Collapse
Affiliation(s)
- Takamitsu J Morikawa
- Laboratory for Comprehensive Bioimaging, RIKEN Center for Biosystems Dynamics Research (BDR), Kobe, Hyogo 650-0047, Japan.,Graduate School of Frontier Bioscience, Osaka University, Suita, Osaka 565-0871, Japan
| | - Masayoshi Nishiyama
- Department of Physics, Kindai University, Higashiosaka, Osaka 577-8502, Japan
| | - Keiko Yoshizawa
- Laboratory for Comprehensive Bioimaging, RIKEN Center for Biosystems Dynamics Research (BDR), Kobe, Hyogo 650-0047, Japan
| | - Hideaki Fujita
- Laboratory for Comprehensive Bioimaging, RIKEN Center for Biosystems Dynamics Research (BDR), Kobe, Hyogo 650-0047, Japan.,Department of Stem Cell Biology, Research Institute for Radiation Biology and Medicine, Hiroshima University, Hiroshima 734-8553, Japan
| | - Tomonobu M Watanabe
- Laboratory for Comprehensive Bioimaging, RIKEN Center for Biosystems Dynamics Research (BDR), Kobe, Hyogo 650-0047, Japan.,Department of Stem Cell Biology, Research Institute for Radiation Biology and Medicine, Hiroshima University, Hiroshima 734-8553, Japan
| |
Collapse
|
27
|
Nexha A, Carvajal JJ, Pujol MC, Díaz F, Aguiló M. Lanthanide doped luminescence nanothermometers in the biological windows: strategies and applications. NANOSCALE 2021; 13:7913-7987. [PMID: 33899861 DOI: 10.1039/d0nr09150b] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The development of lanthanide-doped non-contact luminescent nanothermometers with accuracy, efficiency and fast diagnostic tools attributed to their versatility, stability and narrow emission band profiles has spurred the replacement of conventional contact thermal probes. The application of lanthanide-doped materials as temperature nanosensors, excited by ultraviolet, visible or near infrared light, and the generation of emissions lying in the biological window regions, I-BW (650 nm-950 nm), II-BW (1000 nm-1350 nm), III-BW (1400 nm-2000 nm) and IV-BW (centered at 2200 nm), are notably growing due to the advantages they present, including reduced phototoxicity and photobleaching, better image contrast and deeper penetration depths into biological tissues. Here, the different mechanisms used in lanthanide ion-doped nanomaterials to sense temperature in these biological windows for biomedical and other applications are summarized, focusing on factors that affect their thermal sensitivity, and consequently their temperature resolution. Comparing the thermometric performance of these nanomaterials in each biological window, we identified the strategies that allow boosting of their sensing properties.
Collapse
Affiliation(s)
- Albenc Nexha
- Universitat Rovira i Virgili, Departament de Química Física i Inorgànica, Física i Cristal·lografia de Materials i Nanomaterials (FiCMA-FiCNA)-EMaS, Campus Sescelades, E-43007, Tarragona, Spain.
| | | | | | | | | |
Collapse
|
28
|
Vanden Bussche F, Kaczmarek AM, Van Speybroeck V, Van Der Voort P, Stevens CV. Overview of N-Rich Antennae Investigated in Lanthanide-Based Temperature Sensing. Chemistry 2021; 27:7214-7230. [PMID: 33539627 DOI: 10.1002/chem.202100007] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2021] [Indexed: 12/20/2022]
Abstract
The market share of noncontact temperature sensors is expending due to fast technological and medical evolutions. In the wide variety of noncontact sensors, lanthanide-based temperature sensors stand out. They benefit from high photostability, relatively long decay times and high quantum yields. To circumvent their low molar light absorption, the incorporation of a light-harvesting antenna is required. This Review provides an overview of the nitrogen-rich antennae in lanthanide-based temperature sensors, emitting in the visible light spectrum, and discusses their temperature sensor ability. The N-rich ligands are incorporated in many different platforms. The investigation of different antennae is required to develop temperature sensors with diverse optical properties and to create a diverse offer for the multiple application fields. Molecular probes, consisting of small molecules, are first discussed. Furthermore, the thermometer properties of ratiometric temperature sensors, based on di- and polynuclear complexes, metal-organic frameworks, periodic mesoporous organosilicas and porous organic polymers, are summarized. The antenna mainly determines the application potential of the ratiometric thermometer. It can be observed that molecular probes are operational in the broad physiological range, metal-organic frameworks are generally very useful in the cryogenic region, periodic mesoporous organosilica show temperature dependency in the physiological range, and porous organic polymers are operative in the cryogenic-to-medium temperature range.
Collapse
Affiliation(s)
- Flore Vanden Bussche
- Department of Green Chemistry and Technology, Ghent University, Ghent, Belgium.,Department of Chemistry, Ghent University, Krijgslaan 281 (S3), 9000, Ghent, Belgium
| | - Anna M Kaczmarek
- Department of Chemistry, Ghent University, Krijgslaan 281 (S3), 9000, Ghent, Belgium
| | | | - Pascal Van Der Voort
- Department of Chemistry, Ghent University, Krijgslaan 281 (S3), 9000, Ghent, Belgium
| | - Christian V Stevens
- Department of Green Chemistry and Technology, Ghent University, Ghent, Belgium
| |
Collapse
|
29
|
Abstract
Temperature is an important factor in the process of life, as thermal energy transfer participates in all biological events in organisms. Due to technical limitations, there is still a lot more information to be explored regarding the correlation between life activities and temperature changes. In recent years, the emergence of a variety of new temperature measurement methods has facilitated further research in this field. Here, we introduce the latest advances in temperature sensors for biological detection and their related applications in metabolic research. Various technologies are discussed in terms of their advantages and shortcomings, and future prospects are presented.
Collapse
Affiliation(s)
- Fangxu Wang
- State Key Laboratory of Bioelectronics, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Yuexia Han
- State Key Laboratory of Bioelectronics, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Ning Gu
- State Key Laboratory of Bioelectronics, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| |
Collapse
|
30
|
Spicer G, Gutierrez-Erlandsson S, Matesanz R, Bernard H, Adam A, Efeyan A, Thompson S. Harnessing DNA for nanothermometry. JOURNAL OF BIOPHOTONICS 2021; 14:e202000341. [PMID: 33128802 PMCID: PMC8009499 DOI: 10.1002/jbio.202000341] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 10/05/2020] [Accepted: 10/20/2020] [Indexed: 06/11/2023]
Abstract
Temperature measurement at the nanoscale has brought insight to a wide array of research interests in modern chemistry, physics, and biology. These measurements have been enabled by the advent of nanothermometers, which relay nanoscale temperature information through the analysis of their intrinsic photophysical behavior. In the past decade, several nanothermometers have been developed including dyes, nanodiamonds, fluorescent proteins, nucleotides, and nanoparticles. However, temperature measurement using intact DNA has not yet been achieved. Here, we present a method to study the temperature sensitivity of the DNA molecule within a physiologic temperature range when complexed with fluorescent dye. We theoretically and experimentally report the temperature sensitivity of the DNA-Hoechst 33342 complex in different sizes of double-stranded oligonucleotides and plasmids, showing its potential use as a nanothermometer. These findings allow for extending the thermal study of DNA to several research fields including DNA nanotechnology, optical tweezers, and DNA nanoparticles.
Collapse
Affiliation(s)
- Graham Spicer
- Wellman Center for Photomedicine, Massachusetts General Hospital, 02114 Boston, MA, USA
- Harvard Medical School, Harvard University, 02115 Boston, MA, USA
| | | | - Ruth Matesanz
- Centro de Investigaciones Biológicas Margarita Salas 28040, Madrid, Spain
| | - Hugo Bernard
- Centro Nacional de Investigaciones Oncológicas (CNIO), 28029 Madrid Spain
| | - Alejandro Adam
- Department of Molecular and Cellular Physiology and Department of Ophthalmology, Albany Medical Center, Albany, 12208 NY, USA
| | - Alejo Efeyan
- Centro Nacional de Investigaciones Oncológicas (CNIO), 28029 Madrid Spain
| | - Sebastian Thompson
- Madrid Institute for Advanced Studies in Nanoscience (IMDEA Nanociencia), C/Faraday 9, Madrid 28049, Spain
- Nanobiotechnology Unit Associated to the National Center for Biotechnology (CNB-CSIC-IMDEA), Madrid 28049, Spain
| |
Collapse
|
31
|
Pitfalls in Monitoring Mitochondrial Temperature Using Charged Thermosensitive Fluorophores. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors8040124] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Mitochondria are the source of internal heat which influences all cellular processes. Hence, monitoring mitochondrial temperature provides a unique insight into cell physiology. Using a thermosensitive fluorescent probe MitoThermo Yellow (MTY), we have shown recently that mitochondria within human cells are maintained at close to 50 °C when active, increasing their temperature locally by about 10 °C. Initially reported in the HEK293 cell line, we confirmed this finding in the HeLa cell line. Delving deeper, using MTY and MTX (MitoThermo X), a modified version of MTY, we unraveled some caveats related to the nature of these charged fluorophores. While enabling the assessment of mitochondrial temperature in HEK and HeLa cell lines, the reactivity of MTY to membrane potential variations in human primary skin fibroblasts precluded local temperature monitoring in these cells. Chemical modification of MTY into MTX did not result in a temperature probe unresponsive to membrane potential variations that could be universally used in any cell type to determine mitochondrial temperature. Thus, the cell-type dependence of MTY in measuring mitochondrial temperature, which is likely due to the variable binding of this dye to specific internal mitochondrial components, should imply cautiousness while using these nanothermometers for mitochondrial temperature analysis.
Collapse
|
32
|
The conundrum of hot mitochondria. BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS 2020; 1862:148348. [PMID: 33248118 DOI: 10.1016/j.bbabio.2020.148348] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 11/10/2020] [Accepted: 11/20/2020] [Indexed: 01/11/2023]
Abstract
The mitochondrion is often referred as the cellular powerhouse because the organelle oxidizes organic acids and NADH derived from nutriments, converting around 40% of the Gibbs free energy change of these reactions into ATP, the major energy currency of cell metabolism. Mitochondria are thus microscopic furnaces that inevitably release heat as a by-product of these reactions, and this contributes to body warming, especially in endotherms like birds and mammals. Over the last decade, the idea has emerged that mitochondria could be warmer than the cytosol, because of their intense energy metabolism. It has even been suggested that our own mitochondria could operate under normal conditions at a temperature close to 50 °C, something difficult to reconcile with the laws of thermal physics. Here, using our combined expertise in biology and physics, we exhaustively review the reports that led to the concept of a hot mitochondrion, which is essentially based on the development and use of a variety of molecular thermosensors whose intrinsic fluorescence is modified by temperature. Then, we discuss the physical concepts of heat diffusion, including mechanisms like phonons scattering, which occur in the nanoscale range. Although most of approaches with thermosensors studies present relatively sparse data and lack absolute temperature calibration, overall, they do support the hypothesis of hot mitochondria. However, there is no convincing physical explanation that would allow the organelle to maintain a higher temperature than its surroundings. We nevertheless proposed some research directions, mainly biological, that might help throw light on this intriguing conundrum.
Collapse
|
33
|
Silva PL, Savchuk OA, Gallo J, García-Hevia L, Bañobre-López M, Nieder JB. Mapping intracellular thermal response of cancer cells to magnetic hyperthermia treatment. NANOSCALE 2020; 12:21647-21656. [PMID: 32766635 DOI: 10.1039/c9nr10370h] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Temperature is a key parameter for optimal cellular function and growth. Temperature perturbation may directly lead to cell death. This can be used in cancer therapies to kill cells in tumors, a therapeutic approach called hyperthermia. To avoid overheating of tumors that may damage healthy tissues, a knowledge of the intracellular temperature reached during the hyperthermia treatment of cancer cells is relevant. Recently, several luminescent intracellular nanothermometers have been proposed; however an application to sense temperature during a hyperthermia treatment is lacking. Here we present a technique to measure intracellular temperature changes in in vitro cancer cell models. For this purpose, we study for the first time the temperature dependence of the green fluorescent protein (GFP)'s fluorescence lifetime parameter. We find the fluorescence lifetime of GFP can be used for nanothermosensing. We use GFP in a bound form to actin filaments as an intracellular thermal reporter. Furthermore, we assess intracellular temperature during in vitro magnetothermal therapy on live HeLa cells incubated with polyacrylic acid-coated iron oxide nanoparticles. Compared to other thermosensitive materials and formulations reported so far, the GFP nanothermosensor is easily expressed via transfection and various GFP variants are commercially available. We foresee that the nanothermometer developed might find widespread applications in cancer therapy research and development.
Collapse
Affiliation(s)
- Pedro L Silva
- Ultrafast Bio- and Nanophotonics Group, INL - International Iberian Nanotechnology Laboratory, 4715-330 Braga, Portugal.
| | | | | | | | | | | |
Collapse
|
34
|
Zhou J, Del Rosal B, Jaque D, Uchiyama S, Jin D. Advances and challenges for fluorescence nanothermometry. Nat Methods 2020; 17:967-980. [PMID: 32989319 DOI: 10.1038/s41592-020-0957-y] [Citation(s) in RCA: 185] [Impact Index Per Article: 46.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 08/17/2020] [Indexed: 12/12/2022]
Abstract
Fluorescent nanothermometers can probe changes in local temperature in living cells and in vivo and reveal fundamental insights into biological properties. This field has attracted global efforts in developing both temperature-responsive materials and detection procedures to achieve sub-degree temperature resolution in biosystems. Recent generations of nanothermometers show superior performance to earlier ones and also offer multifunctionality, enabling state-of-the-art functional imaging with improved spatial, temporal and temperature resolutions for monitoring the metabolism of intracellular organelles and internal organs. Although progress in this field has been rapid, it has not been without controversy, as recent studies have shown possible biased sensing during fluorescence-based detection. Here, we introduce the design principles and advances in fluorescence nanothermometry, highlight application achievements, discuss scenarios that may lead to biased sensing, analyze the challenges ahead in terms of both fundamental issues and practical implementations, and point to new directions for improving this interdisciplinary field.
Collapse
Affiliation(s)
- Jiajia Zhou
- Institute for Biomedical Materials & Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, Australia.
| | - Blanca Del Rosal
- ARC Centre of Excellence for Nanoscale Biophotonics, RMIT University, Melbourne, Australia
| | - Daniel Jaque
- Nanobiology Group, Instituto Ramón y Cajal de Investigación Sanitaria, IRYCIS, Madrid, Spain. .,Fluorescence Imaging Group, Departamento de Física de Materiales-Facultad de Ciencias, Universidad Autónoma de Madrid, Madrid, Spain.
| | - Seiichi Uchiyama
- Graduate School of Pharmaceutical Sciences, The University of Tokyo, Tokyo, Japan
| | - Dayong Jin
- Institute for Biomedical Materials & Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, Australia.,Department of Biomedical Engineering, Southern University of Science and Technology, Guangdong, China
| |
Collapse
|
35
|
Piñol R, Zeler J, Brites CDS, Gu Y, Téllez P, Carneiro Neto AN, da Silva TE, Moreno-Loshuertos R, Fernandez-Silva P, Gallego AI, Martinez-Lostao L, Martínez A, Carlos LD, Millán A. Real-Time Intracellular Temperature Imaging Using Lanthanide-Bearing Polymeric Micelles. NANO LETTERS 2020; 20:6466-6472. [PMID: 32787172 DOI: 10.1021/acs.nanolett.0c02163] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Measurement of thermogenesis in individual cells is a remarkable challenge due to the complexity of the biochemical environment (such as pH and ionic strength) and to the rapid and yet not well-understood heat transfer mechanisms throughout the cell. Here, we present a unique system for intracellular temperature mapping in a fluorescence microscope (uncertainty of 0.2 K) using rationally designed luminescent Ln3+-bearing polymeric micellar probes (Ln = Sm, Eu) incubated in breast cancer MDA-MB468 cells. Two-dimensional (2D) thermal images recorded increasing the temperature of the cells culture medium between 296 and 304 K shows inhomogeneous intracellular temperature progressions up to ∼20 degrees and subcellular gradients of ∼5 degrees between the nucleolus and the rest of the cell, illustrating the thermogenic activity of the different organelles and highlighting the potential of this tool to study intracellular processes.
Collapse
Affiliation(s)
- Rafael Piñol
- ICMA, Institute of Materials Science of Aragon, CSIC, University of Zaragoza, 50008 Zaragoza, Spain
| | - Justyna Zeler
- Phantom-g, CICECO-Aveiro Institute of Materials, Department of Physics, University of Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal
- Faculty of Chemistry, University of Wroclaw, Wroclaw 50-302, Poland
| | - Carlos D S Brites
- Phantom-g, CICECO-Aveiro Institute of Materials, Department of Physics, University of Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal
| | - Yuanyu Gu
- ICMA, Institute of Materials Science of Aragon, CSIC, University of Zaragoza, 50008 Zaragoza, Spain
- School of Materials Science and Engineering, Nanjing Tech University, 210009 Nanjing, People's Republic of China
| | - Pedro Téllez
- Servicio de Apoyo a la Investigación, University of Zaragoza, C/Pedro Cerbuna 10, 50006 Zaragoza, Spain
| | - Albano N Carneiro Neto
- Phantom-g, CICECO-Aveiro Institute of Materials, Department of Physics, University of Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal
| | - Thiago E da Silva
- Phantom-g, CICECO-Aveiro Institute of Materials, Department of Physics, University of Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal
- Department of Fundamental Chemistry, Federal University of Pernambuco, 50670-901 Recife, Pernambuco, Brazil
| | - Raquel Moreno-Loshuertos
- Departamento de Bioquímica, Biología Molecular y Celular, University of Zaragoza, 50018 Zaragoza, Spain
| | - Patrício Fernandez-Silva
- Departamento de Bioquímica, Biología Molecular y Celular, University of Zaragoza, 50018 Zaragoza, Spain
| | - Ana Isabel Gallego
- Departamento de Bioquímica, Biología Molecular y Celular, University of Zaragoza, 50018 Zaragoza, Spain
| | - Luis Martinez-Lostao
- Departamento de Bioquímica, Biología Molecular y Celular, University of Zaragoza, 50018 Zaragoza, Spain
| | - Abelardo Martínez
- Departamento de Electrónica de Potencia, I3A, University of Zaragoza, 50018 Zaragoza, Spain
| | - Luís D Carlos
- Phantom-g, CICECO-Aveiro Institute of Materials, Department of Physics, University of Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal
| | - Angel Millán
- ICMA, Institute of Materials Science of Aragon, CSIC, University of Zaragoza, 50008 Zaragoza, Spain
| |
Collapse
|
36
|
Sugimura T, Kajimoto S, Nakabayashi T. Label‐Free Imaging of Intracellular Temperature by Using the O−H Stretching Raman Band of Water. Angew Chem Int Ed Engl 2020. [DOI: 10.1002/ange.201915846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Toshiki Sugimura
- Graduate School of Pharmaceutical Sciences Tohoku University, Aoba-ku Sendai 980–8578 Japan
| | - Shinji Kajimoto
- Graduate School of Pharmaceutical Sciences Tohoku University, Aoba-ku Sendai 980–8578 Japan
| | - Takakazu Nakabayashi
- Graduate School of Pharmaceutical Sciences Tohoku University, Aoba-ku Sendai 980–8578 Japan
| |
Collapse
|
37
|
Sugimura T, Kajimoto S, Nakabayashi T. Label‐Free Imaging of Intracellular Temperature by Using the O−H Stretching Raman Band of Water. Angew Chem Int Ed Engl 2020; 59:7755-7760. [DOI: 10.1002/anie.201915846] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Revised: 01/19/2020] [Indexed: 12/22/2022]
Affiliation(s)
- Toshiki Sugimura
- Graduate School of Pharmaceutical Sciences Tohoku University, Aoba-ku Sendai 980–8578 Japan
| | - Shinji Kajimoto
- Graduate School of Pharmaceutical Sciences Tohoku University, Aoba-ku Sendai 980–8578 Japan
| | - Takakazu Nakabayashi
- Graduate School of Pharmaceutical Sciences Tohoku University, Aoba-ku Sendai 980–8578 Japan
| |
Collapse
|