1
|
Dziobak MK, Fahlman A, Wells RS, Takeshita R, Smith C, Gray A, Weinstein J, Hart LB. First evidence of microplastic inhalation among free-ranging small cetaceans. PLoS One 2024; 19:e0309377. [PMID: 39413051 PMCID: PMC11482699 DOI: 10.1371/journal.pone.0309377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Accepted: 08/09/2024] [Indexed: 10/18/2024] Open
Abstract
Plastic is a ubiquitous environmental contaminant, resulting in widespread exposure across terrestrial and marine spaces. In the environment, plastics can degrade into microparticles where exposure has been documented in a variety of fauna at all trophic levels. Human epidemiological studies have found relationships between inhaled microplastics and oxidative stress and inflammation. Previous studies of bottlenose dolphins (Tursiops truncatus) have reported prevalent exposure to plasticizing chemicals (e.g., phthalates) as well as particle loads in gastrointestinal tracts, but exposure from inhalation has not yet been studied. The objective of this study was to determine if inhalation is a viable route of microplastic exposure for free-ranging dolphins. Exhalation samples were opportunistically collected from dolphins residing in Sarasota Bay, Florida (n = 5) and Barataria Bay, Louisiana (n = 6) during catch-and-release health assessments to screen for microplastic particles. All dolphin samples contained at least one suspected microplastic particle, and polymer composition was determined for 100% of a subset (n = 17) of samples. Additional studies are warranted to better understand the extent of inhaled microplastics, as well as to explore impacts, given potential risks to lung function and health.
Collapse
Affiliation(s)
- Miranda K. Dziobak
- Department of Health and Human Performance, School of Health Sciences, College of Charleston, Charleston, SC, United States of America
- Department of Environmental Health Sciences, Arnold School of Public Health, University of South Carolina, Columbia, SC, United States of America
| | - Andreas Fahlman
- Fundacion Oceanografic, Valencia, Spain
- Global Diving Research, Sanlucar de Barrameda, Spain
- IFM, Linkoping University, Linkoping, Sweden
| | - Randall S. Wells
- Chicago Zoological Society’s Sarasota Dolphin Research Program, ℅ Mote Marine Laboratory, Sarasota, FL, United States of America
| | - Ryan Takeshita
- National Marine Mammal Foundation, San Diego, CA, United States of America
| | - Cynthia Smith
- National Marine Mammal Foundation, San Diego, CA, United States of America
| | - Austin Gray
- Department of Biological Sciences, Virginia Tech, Blacksburg, VA, United States of America
| | - John Weinstein
- Department of Biology, The Citadel, Charleston, SC, United States of America
| | - Leslie B. Hart
- Department of Health and Human Performance, School of Health Sciences, College of Charleston, Charleston, SC, United States of America
| |
Collapse
|
2
|
Taylor-Blair HC, Siu ACW, Haysom-McDowell A, Kokkinis S, Bani Saeid A, Chellappan DK, Oliver BGG, Paudel KR, De Rubis G, Dua K. The impact of airborne particulate matter-based pollution on the cellular and molecular mechanisms in chronic obstructive pulmonary disease (COPD). THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 954:176413. [PMID: 39322084 DOI: 10.1016/j.scitotenv.2024.176413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2024] [Revised: 08/26/2024] [Accepted: 09/18/2024] [Indexed: 09/27/2024]
Abstract
Inhalation of particulate matter (PM), one of the many components of air pollution, is associated with the development and exacerbation of chronic respiratory diseases, such as chronic obstructive pulmonary disease (COPD). COPD is one of the leading causes of global mortality and morbidity, with a paucity of therapeutic options and a significant contributor to global health expenditure. This review aims to provide a mechanistic understanding of the cellular and molecular pathways that lead to the development of COPD following chronic PM exposure. Our review describes how the inhalation of PM can lead to lung parenchymal destruction and cellular senescence due to chronic pulmonary inflammation and oxidative stress. Following inhalation of PM, significant increases in a range of pro-inflammatory cytokines, mediated by the nuclear factor kappa B pathway are reported. This review also highlights how the inhalation of PM can lead to deleterious chronic oxidative stress persisting in the lung post-exposure. Furthermore, our work summarises how PM inhalation can lead to airway remodelling, with increases in pro-fibrotic cytokines and collagen deposition, typical of COPD. This paper also accentuates the interconnection and possible synergism between the pathophysiological mechanisms leading to COPD. Our work emphasises the serious health consequences of PM exposure on respiratory health. Elucidation of the cellular and molecular mechanisms can provide insight into possible therapeutic options. Finally, this review should serve as a stark reminder of the need for genuine action on air pollution to decrease the associated health burden on our growing global population.
Collapse
Affiliation(s)
- Hudson C Taylor-Blair
- School of Life Sciences, Faculty of Science, University of Technology Sydney, Ultimo, NSW 2007, Australia; Discipline of Pharmacy, Graduate School of Health, University of Technology Sydney, Ultimo, NSW 2007, Australia
| | - Alexander Chi Wang Siu
- Discipline of Pharmacy, Graduate School of Health, University of Technology Sydney, Ultimo, NSW 2007, Australia
| | - Adam Haysom-McDowell
- Discipline of Pharmacy, Graduate School of Health, University of Technology Sydney, Ultimo, NSW 2007, Australia; Faculty of Health, Australian Research Centre in Complementary and Integrative Medicine, University of Technology Sydney, Ultimo, NSW 2007, Australia
| | - Sofia Kokkinis
- Discipline of Pharmacy, Graduate School of Health, University of Technology Sydney, Ultimo, NSW 2007, Australia; Faculty of Health, Australian Research Centre in Complementary and Integrative Medicine, University of Technology Sydney, Ultimo, NSW 2007, Australia
| | - Ayeh Bani Saeid
- Discipline of Pharmacy, Graduate School of Health, University of Technology Sydney, Ultimo, NSW 2007, Australia; Faculty of Health, Australian Research Centre in Complementary and Integrative Medicine, University of Technology Sydney, Ultimo, NSW 2007, Australia
| | - Dinesh Kumar Chellappan
- Department of Life Sciences, School of Pharmacy, International Medical University, Bukit Jalil, 57000 Kuala Lumpur, Malaysia
| | - Brian G G Oliver
- School of Life Sciences, Faculty of Science, University of Technology Sydney, Ultimo, NSW 2007, Australia; Respiratory Cellular and Molecular Biology, Woolcock Institute of Medical Research, Macquarie Park, NSW 2113, Australia
| | - Keshav Raj Paudel
- Centre for Inflammation, Centenary Institute, University of Technology Sydney, School of Life Sciences, Faculty of Science, Ultimo, NSW 2007, Australia
| | - Gabriele De Rubis
- Discipline of Pharmacy, Graduate School of Health, University of Technology Sydney, Ultimo, NSW 2007, Australia; Faculty of Health, Australian Research Centre in Complementary and Integrative Medicine, University of Technology Sydney, Ultimo, NSW 2007, Australia.
| | - Kamal Dua
- Discipline of Pharmacy, Graduate School of Health, University of Technology Sydney, Ultimo, NSW 2007, Australia; Faculty of Health, Australian Research Centre in Complementary and Integrative Medicine, University of Technology Sydney, Ultimo, NSW 2007, Australia.
| |
Collapse
|
3
|
Salana S, Verma V. Review of in vitro studies evaluating respiratory toxicity of aerosols: impact of cell types, chemical composition, and atmospheric processing. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2024. [PMID: 39291816 DOI: 10.1039/d4em00475b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/19/2024]
Abstract
In recent decades, several cell-based and acellular methods have been developed to evaluate ambient particulate matter (PM) toxicity. Although cell-based methods provide a more comprehensive assessment of PM toxicity, their results are difficult to comprehend due to the diversity in cellular endpoints, cell types, and assays and the interference of PM chemical components with some of the assays' techniques. In this review, we attempt to clarify some of these issues. We first discuss the morphological and immunological differences among various macrophage and epithelial cells, belonging to the respiratory systems of human and murine species, used in the in vitro studies evaluating PM toxicity. Then, we review the current state of knowledge on the role of different PM chemical components and the relevance of atmospheric processing and aging of aerosols in the respiratory toxicity of PM. Our review demonstrates the need to adopt more physiologically relevant cellular models such as epithelial (or endothelial) cells instead of macrophages for oxidative stress measurement. We suggest limiting macrophages for investigating other cellular responses (e.g., phagocytosis, inflammation, and DNA damage). Unlike monocultures (of macrophages and epithelial cells), which are generally used to study the direct effects of PM on a given cell type, the use of co-culture systems should be encouraged to investigate a more comprehensive effect of PM in the presence of other cells. Our review has identified two major groups of toxic PM chemical species from the existing literature, i.e., metals (Fe, Cu, Mn, Cr, Ni, and Zn) and organic compounds (PAHs, ketones, aliphatic and chlorinated hydrocarbons, and quinones). However, the relative toxicities of these species are still a matter of debate. Finally, the results of the existing studies investigating the effect of aging on PM toxicity are ambiguous, with varying results due to different cell types, different aging conditions, and the presence/absence of specific oxidants. More systematic studies are necessary to understand the role of different SOA precursors, interactions between different PM components, and aging conditions in the overall toxicity of PM. We anticipate that our review will guide future investigations by helping researchers choose appropriate cell models, resulting in a more meaningful interpretation of cell-based assays and thus ultimately leading to a better understanding of the health effects of PM exposure.
Collapse
Affiliation(s)
- Sudheer Salana
- Department of Civil and Environmental Engineering, University of Illinois at Urbana Champaign, Urbana, 61801, USA.
| | - Vishal Verma
- Department of Civil and Environmental Engineering, University of Illinois at Urbana Champaign, Urbana, 61801, USA.
| |
Collapse
|
4
|
Zhang Y, Zhang Z, Mo Y, Zhang Y, Yuan J, Zhang Q. MMP-3 mediates copper oxide nanoparticle-induced pulmonary inflammation and fibrosis. J Nanobiotechnology 2024; 22:428. [PMID: 39030581 PMCID: PMC11264740 DOI: 10.1186/s12951-024-02707-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Accepted: 07/05/2024] [Indexed: 07/21/2024] Open
Abstract
BACKGROUND The increasing production and usage of copper oxide nanoparticles (Nano-CuO) raise human health concerns. Previous studies have demonstrated that exposure to Nano-CuO could induce lung inflammation, injury, and fibrosis. However, the potential underlying mechanisms are still unclear. Here, we proposed that matrix metalloproteinase-3 (MMP-3) might play an important role in Nano-CuO-induced lung inflammation, injury, and fibrosis. RESULTS Exposure of mice to Nano-CuO caused acute lung inflammation and injury in a dose-dependent manner, which was reflected by increased total cell number, neutrophil count, macrophage count, lactate dehydrogenase (LDH) activity, and CXCL1/KC level in bronchoalveolar lavage fluid (BALF) obtained on day 3 post-exposure. The time-response study showed that Nano-CuO-induced acute lung inflammation and injury appeared as early as day 1 after exposure, peaked on day 3, and ameliorated over time. However, even on day 42 post-exposure, the LDH activity and macrophage count were still higher than those in the control group, suggesting that Nano-CuO caused chronic lung inflammation. The Nano-CuO-induced pulmonary inflammation was further confirmed by H&E staining of lung sections. Trichrome staining showed that Nano-CuO exposure caused pulmonary fibrosis from day 14 to day 42 post-exposure with an increasing tendency over time. Increased hydroxyproline content and expression levels of fibrosis-associated proteins in mouse lungs were also observed. In addition, Nano-CuO exposure induced MMP-3 overexpression and increased MMP-3 secretion in mouse lungs. Knocking down MMP-3 in mouse lungs significantly attenuated Nano-CuO-induced acute and chronic lung inflammation and fibrosis. Moreover, Nano-CuO exposure caused sustained production of cleaved osteopontin (OPN) in mouse lungs, which was also significantly decreased by knocking down MMP-3. CONCLUSIONS Our results demonstrated that short-term Nano-CuO exposure caused acute lung inflammation and injury, while long-term exposure induced chronic pulmonary inflammation and fibrosis. Knocking down MMP-3 significantly ameliorated Nano-CuO-induced pulmonary inflammation, injury, and fibrosis, and also attenuated Nano-CuO-induced cleaved OPN level. Our study suggests that MMP-3 may play important roles in Nano-CuO-induced pulmonary inflammation and fibrosis via cleavage of OPN and may provide a further understanding of the mechanisms underlying Nano-CuO-induced pulmonary toxicity.
Collapse
Affiliation(s)
- Yuanbao Zhang
- Department of Epidemiology and Population Health, School of Public Health and Information Sciences, University of Louisville, 485 E. Gray Street, Louisville, KY, 40202, USA
- Beijing Key Laboratory of Occupational Safety and Health, Institute of Urban Safety and Environmental Science, Beijing Academy of Science and Technology, Beijing, 100054, China
| | - Zhenyu Zhang
- Department of Emergency, Xiang'An Hospital of Xiamen University, Xiamen, 361104, Fujian, China
| | - Yiqun Mo
- Department of Epidemiology and Population Health, School of Public Health and Information Sciences, University of Louisville, 485 E. Gray Street, Louisville, KY, 40202, USA
| | - Yue Zhang
- Indiana University School of Medicine, Indianapolis, IN, 46202, USA
| | - Jiali Yuan
- Department of Epidemiology and Population Health, School of Public Health and Information Sciences, University of Louisville, 485 E. Gray Street, Louisville, KY, 40202, USA
| | - Qunwei Zhang
- Department of Epidemiology and Population Health, School of Public Health and Information Sciences, University of Louisville, 485 E. Gray Street, Louisville, KY, 40202, USA.
| |
Collapse
|
5
|
Neukirchen C, Meiners T, Bendl J, Zimmermann R, Adam T. Automated SEM/EDX imaging for the in-depth characterization of non-exhaust traffic emissions from the Munich subway system. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 915:170008. [PMID: 38220016 DOI: 10.1016/j.scitotenv.2024.170008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2023] [Revised: 12/27/2023] [Accepted: 01/06/2024] [Indexed: 01/16/2024]
Abstract
A SEM/EDX based automated measurement and classification algorithm was tested as a method for the in-depth analysis of micro-environments in the Munich subway using a custom build mobile measurements system. Sampling was conducted at platform stations, to investigate the personal exposure of commuters to subway particulate matter during platform stays. EDX spectra and morphological features of all analyzed particles were automatically obtained and particles were automatically classified based on pre-defined chemical and morphological boundaries. Source apportionment for individual particles, such as abrasion processes at the wheel-brake interface, was partially possible based on the established particle classes. An average of 98.87 ± 1.06 % of over 200,000 analyzed particles were automatically assigned to the pre-defined classes, with 84.68 ± 16.45 % of particles classified as highly ferruginous. Manual EDX analysis further revealed, that heavy metal rich particles were also present in the ultrafine size range well below 100 nm.
Collapse
Affiliation(s)
- Carsten Neukirchen
- University of the Bundeswehr Munich, Faculty for Mechanical Engineering, Institute of Chemical and Environmental Engineering, Werner-Heisenberg-Weg 39, 85577 Neubiberg, Germany; Joint Mass Spectrometry Center (JMSC) at Chair of Analytical Chemistry, Institute of Chemistry, University of Rostock, Albert-Einstein-Strasse 27, 18059 Rostock, Germany
| | - Thorsten Meiners
- Oxford Instruments GmbH, Borsigstraße 15 A, 652025 Wiesbaden, Germany
| | - Jan Bendl
- University of the Bundeswehr Munich, Faculty for Mechanical Engineering, Institute of Chemical and Environmental Engineering, Werner-Heisenberg-Weg 39, 85577 Neubiberg, Germany; Institute for Environmental Studies, Faculty of Science, Charles University, Benátská 2, 128 01 Prague, Czech Republic.
| | - Ralf Zimmermann
- Joint Mass Spectrometry Center (JMSC) at Comprehensive Molecular Analytics (CMA), Department Environmental Health, Helmholtz Munich, Gmunder Str. 37, 81379 München, Germany; Joint Mass Spectrometry Center (JMSC) at Chair of Analytical Chemistry, Institute of Chemistry, University of Rostock, Albert-Einstein-Strasse 27, 18059 Rostock, Germany
| | - Thomas Adam
- University of the Bundeswehr Munich, Faculty for Mechanical Engineering, Institute of Chemical and Environmental Engineering, Werner-Heisenberg-Weg 39, 85577 Neubiberg, Germany; Joint Mass Spectrometry Center (JMSC) at Comprehensive Molecular Analytics (CMA), Department Environmental Health, Helmholtz Munich, Gmunder Str. 37, 81379 München, Germany
| |
Collapse
|
6
|
Eka Rani YD, Rahmadi M, Hariyadi DM. Characteristics and release of isoniazid from inhalable alginate/carrageenan microspheres. Ther Deliv 2023; 14:689-704. [PMID: 38084393 DOI: 10.4155/tde-2023-0064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2023] Open
Abstract
Aim: Inhalable microspheres made of polymers as a targeted drug delivery system have been developed to overcome the limitation of current treatments in Tuberculosis. Materials & methods: Isoniazid inhalable microspheres were created using a gelation ionotropic method with sodium alginate, carrageenan and calcium chloride in four different formulations. Result: The particle morphology has smooth surfaces and round spherical shapes with sizes below 5 μm; good flowability. The drug loading and entrapment efficiency values ranged from 1.69 to 2.75% and 62.44 to 85.30%, respectively. The microspheres drug release followed the Korsmeyer-Peppas model, indicating Fickian diffusion. Conclusion: Isoniazid inhalable microspheres achieved as targeted lung delivery for tuberculosis treatment.
Collapse
Affiliation(s)
- Yotomi Desia Eka Rani
- Department of Pharmaceutical Sciences, Faculty of Pharmacy, Universitas Airlangga, Campus C Mulyorejo, Surabaya, 60115, Indonesia
| | - Mahardian Rahmadi
- Department of Pharmacy Practice, Faculty of Pharmacy, Universitas Airlangga, Campus C Jl. Mulyorejo, Surabaya, 60115, Indonesia
| | - Dewi Melani Hariyadi
- Department of Pharmaceutical Sciences, Faculty of Pharmacy, Universitas Airlangga, Campus C Mulyorejo, Surabaya, 60115, Indonesia
- Nanotechnology & Drug Delivery System Research Group, Faculty of Pharmacy, Universitas Airlangga, Campus C Mulyorejo, Surabaya, 60115, Indonesia
| |
Collapse
|
7
|
Mendez S, Garcia W, Nicolas A. From Microscopic Droplets to Macroscopic Crowds: Crossing the Scales in Models of Short-Range Respiratory Disease Transmission, with Application to COVID-19. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2205255. [PMID: 37132608 PMCID: PMC10323631 DOI: 10.1002/advs.202205255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Revised: 03/14/2023] [Indexed: 05/04/2023]
Abstract
Short-range exposure to airborne virus-laden respiratory droplets is an effective transmission route of respiratory diseases, as exemplified by Coronavirus Disease 2019 (COVID-19). In order to assess the risks associated with this pathway in daily-life settings involving tens to hundreds of individuals, the chasm needs to be bridged between fluid dynamical simulations and population-scale epidemiological models. This is achieved by simulating droplet trajectories at the microscale in numerous ambient flows, coarse-graining their results into spatio-temporal maps of viral concentration around the emitter, and coupling these maps to field-data about pedestrian crowds in different scenarios (streets, train stations, markets, queues, and street cafés). At the individual scale, the results highlight the paramount importance of the velocity of the ambient air flow relative to the emitter's motion. This aerodynamic effect, which disperses infectious aerosols, prevails over all other environmental variables. At the crowd's scale, the method yields a ranking of the scenarios by the risks of new infections, dominated by the street cafés and then the outdoor market. While the effect of light winds on the qualitative ranking is fairly marginal, even the most modest air flows dramatically lower the quantitative rates of new infections.
Collapse
Affiliation(s)
- Simon Mendez
- IMAGUniv. MontpellierCNRSMontpellierF‐34095France
| | - Willy Garcia
- Institut Lumière Matière, CNRSUniv. Claude Bernard Lyon 1VilleurbanneF‐69622France
| | - Alexandre Nicolas
- Institut Lumière Matière, CNRSUniv. Claude Bernard Lyon 1VilleurbanneF‐69622France
| |
Collapse
|
8
|
Peng Y, Yao M. Quantitatively Visualizing Airborne Disease Transmission Risks of Different Exhalation Activities through CO 2 Imaging. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:6865-6875. [PMID: 37074044 PMCID: PMC10124748 DOI: 10.1021/acs.est.2c08503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 03/23/2023] [Accepted: 04/03/2023] [Indexed: 05/03/2023]
Abstract
Aerosol transmission has played a leading role in COVID-19 pandemic. However, there is still a poor understanding about how it is transmitted. This work was designed to study the exhaled breath flow dynamics and transmission risks under different exhaling modes. Using an infrared photography device, exhaled flow characteristics of different breathing activities, such as deep breathing, dry coughing, and laughing, together with the roles of mouth and nose were characterized by imaging CO2 flow morphologies. Both mouth and nose played an important role in the disease transmission though in the downward direction for the nose. In contrast to the trajectory commonly modeled, the exhaled airflows appeared with turbulent entrainments and obvious irregular movements, particularly the exhalations involving mouth were directed horizontal and had a higher propagation capacity and transmission risk. While the cumulative risk was high for deep breathing, those transient ones from dry coughing, yawning, and laughing were also shown to be significant. Various protective measures including masks, canteen table shields, and wearable devices were visually demonstrated to be effective for altering the exhaled flow directions. This work is useful to understanding the risk of aerosol infection and guiding the formulation of its prevention and control strategies. Experimental data also provide important information for refining model boundary conditions.
Collapse
Affiliation(s)
- Yijiao Peng
- State Key Joint Laboratory of Environmental Simulation and
Pollution Control, College of Environmental Sciences and Engineering, Peking
University, Beijing 100871, China
| | - Maosheng Yao
- State Key Joint Laboratory of Environmental Simulation and
Pollution Control, College of Environmental Sciences and Engineering, Peking
University, Beijing 100871, China
| |
Collapse
|
9
|
Pena M, Neu DT, Feng HA, Hammond DR, Mead KR, Banerjee RK. Use of a Negative Pressure Containment Pod Within Ambulance-Workspace During Pandemic Response. J Med Device 2023; 17:011009. [PMID: 36890857 PMCID: PMC9987460 DOI: 10.1115/1.4056694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 12/02/2022] [Indexed: 01/17/2023] Open
Abstract
Emergency medical service (EMS) providers have a higher potential exposure to infectious agents than the general public (Nguyen et al., 2020, "Risk of COVID-19 Among Frontline Healthcare Workers and the General Community: A Prospective Cohort Study," Lancet Pub. Health, 5(9), pp. e475-e483; Brown et al., 2021, "Risk for Acquiring Coronavirus Disease Illness Among Emergency Medical Service Personnel Exposed to Aerosol-Generating Procedures," Emer. Infect. Disease J., 27(9), p. 2340). The use of protective equipment may reduce, but does not eliminate their risk of becoming infected as a result of these exposures. Prehospital environments have a high risk of disease transmission exposing EMS providers to bioaerosols and droplets from infectious patients. Field intubation procedures may be performed causing the generation of bioaerosols, thereby increasing the exposure of EMS workers to pathogens. Additionally, ambulances have a reduced volume compared to a hospital treatment space, often without an air filtration system, and no control mechanism to reduce exposure. This study evaluated a containment plus filtration intervention for reducing aerosol concentrations in the patient module of an ambulance. Aerosol concentration measurements were taken in an unoccupied research ambulance at National Institute for Occupational Safety and Health (NIOSH) Cincinnati using a tracer aerosol and optical particle counters (OPCs). The evaluated filtration intervention was a containment pod with a high efficiency particulate air (HEPA)-filtered extraction system that was developed and tested based on its ability to contain, capture, and remove aerosols during the intubation procedure. Three conditions were tested (1) baseline (without intervention), (2) containment pod with HEPA-1, and (3) containment pod with HEPA-2. The containment pod with HEPA-filtered extraction intervention provided containment of 95% of the total generated particle concentration during aerosol generation relative to the baseline condition, followed by rapid air cleaning within the containment pod. This intervention can help reduce aerosol concentrations within ambulance patient modules while performing aerosol-generating procedures.
Collapse
Affiliation(s)
- Mirle Pena
- Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH 45226; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH 45221
| | - Dylan T. Neu
- Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH 45226
| | - H. Amy Feng
- Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH 45226
| | - Duane R. Hammond
- Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH 45226
| | - Kenneth R. Mead
- Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH 45226
| | - Rupak K. Banerjee
- Department of Mechanical and Biomedical Engineering, University of Cincinnati, 593 Rhodes Hall, 2600 Clifton Ave, Cincinnati, OH 45221
| |
Collapse
|
10
|
Bessa MJ, Brandão F, Rosário F, Moreira L, Reis AT, Valdiglesias V, Laffon B, Fraga S, Teixeira JP. Assessing the in vitro toxicity of airborne (nano)particles to the human respiratory system: from basic to advanced models. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART B, CRITICAL REVIEWS 2023; 26:67-96. [PMID: 36692141 DOI: 10.1080/10937404.2023.2166638] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Several studies have been conducted to address the potential adverse health risks attributed to exposure to nanoscale materials. While in vivo studies are fundamental for identifying the relationship between dose and occurrence of adverse effects, in vitro model systems provide important information regarding the mechanism(s) of action at the molecular level. With a special focus on exposure to inhaled (nano)particulate material toxicity assessment, this review provides an overview of the available human respiratory models and exposure systems for in vitro testing, advantages, limitations, and existing investigations using models of different complexity. A brief overview of the human respiratory system, pathway and fate of inhaled (nano)particles is also presented.
Collapse
Affiliation(s)
- Maria João Bessa
- Departamento de Saúde Ambiental, Instituto Nacional de Saúde Doutor Ricardo Jorge, Porto, Portugal
- EPIUnit, Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal
- Laboratório para a Investigação Integrativa e Translacional em Saúde Populacional (ITR), Porto, Portugal
- Instituto de Ciências Biomédicas Abel Salazar (ICBAS), Universidade do Porto, Porto, Portugal
| | - Fátima Brandão
- Departamento de Saúde Ambiental, Instituto Nacional de Saúde Doutor Ricardo Jorge, Porto, Portugal
- EPIUnit, Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal
- Laboratório para a Investigação Integrativa e Translacional em Saúde Populacional (ITR), Porto, Portugal
- Instituto de Ciências Biomédicas Abel Salazar (ICBAS), Universidade do Porto, Porto, Portugal
| | - Fernanda Rosário
- Departamento de Saúde Ambiental, Instituto Nacional de Saúde Doutor Ricardo Jorge, Porto, Portugal
- EPIUnit, Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal
- Laboratório para a Investigação Integrativa e Translacional em Saúde Populacional (ITR), Porto, Portugal
| | - Luciana Moreira
- Departamento de Saúde Ambiental, Instituto Nacional de Saúde Doutor Ricardo Jorge, Porto, Portugal
- EPIUnit, Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal
- Laboratório para a Investigação Integrativa e Translacional em Saúde Populacional (ITR), Porto, Portugal
| | - Ana Teresa Reis
- Departamento de Saúde Ambiental, Instituto Nacional de Saúde Doutor Ricardo Jorge, Porto, Portugal
- EPIUnit, Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal
- Laboratório para a Investigação Integrativa e Translacional em Saúde Populacional (ITR), Porto, Portugal
| | - Vanessa Valdiglesias
- Departamento de Biología, Universidade da Coruña, Grupo NanoToxGen, Centro Interdisciplinar de Química e Bioloxía - CICA, A Coruña, Spain
- Instituto de Investigación Biomédica de A Coruña (INIBIC), A Coruña, Spain
| | - Blanca Laffon
- Instituto de Investigación Biomédica de A Coruña (INIBIC), A Coruña, Spain
- Departamento de Psicología, Universidade da Coruña, Grupo DICOMOSA, Centro Interdisciplinar de Química e Bioloxía - CICA, A Coruña, Spain
| | - Sónia Fraga
- Departamento de Saúde Ambiental, Instituto Nacional de Saúde Doutor Ricardo Jorge, Porto, Portugal
- EPIUnit, Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal
- Laboratório para a Investigação Integrativa e Translacional em Saúde Populacional (ITR), Porto, Portugal
- Department of Biomedicine, Unit of Pharmacology and Therapeutics, Faculty of Medicine, University of Porto, Porto, Portugal
| | - João Paulo Teixeira
- Departamento de Saúde Ambiental, Instituto Nacional de Saúde Doutor Ricardo Jorge, Porto, Portugal
- EPIUnit, Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal
- Laboratório para a Investigação Integrativa e Translacional em Saúde Populacional (ITR), Porto, Portugal
| |
Collapse
|
11
|
Nishandar SR, He Y, Princevac M, Edwards RD. Fate of Exhaled Droplets From Breathing and Coughing in Supermarket Checkouts and Passenger Cars. ENVIRONMENTAL HEALTH INSIGHTS 2023; 17:11786302221148274. [PMID: 36644342 PMCID: PMC9834932 DOI: 10.1177/11786302221148274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 12/12/2022] [Indexed: 06/17/2023]
Abstract
The global pandemic of COVID-19 has highlighted the importance of understanding the role that exhaled droplets play in virus transmission in community settings. Computational Fluid Dynamics (CFD) enables systematic examination of roles the exhaled droplets play in the spread of SARS-CoV-2 in indoor environments. This analysis uses published exhaled droplet size distributions combined with terminal aerosol droplet size based on measured peak concentrations for SARS-CoV-2 RNA in aerosols to simulate exhaled droplet dispersion, evaporation, and deposition in a supermarket checkout area and rideshare car where close proximity with other individuals is common. Using air inlet velocity of 2 m/s in the passenger car and ASHRAE recommendations for ventilation and comfort in the supermarket, simulations demonstrate that exhaled droplets <20 μm that contain the majority of viral RNA evaporated leaving residual droplet nuclei that remain aerosolized in the air. Subsequently ~ 70% of these droplet nuclei deposited in the supermarket and the car with the reminder vented from the space. The maximum surface deposition of droplet nuclei/m2 for speaking and coughing were 2 and 819, 18 and 1387 for supermarket and car respectively. Approximately 15% of the total exhaled droplets (aerodynamic diameters 20-700 µm) were deposited on surfaces in close proximity to the individual. Due to the non-linear distribution of viral RNA across droplet sizes, however, these larger exhaled droplets that deposit on surfaces have low viral content. Maximum surface deposition of viral RNA was 70 and 1.7 × 103 virions/m2 for speaking and 2.3 × 104 and 9.3 × 104 virions/m2 for coughing in the supermarket and car respectively while the initial airborne concentration of viral RNA was 7 × 106 copies per ml. Integrating the droplet size distributions with viral load distributions, this study helps explain the apparent importance of inhalation exposures compared to surface contact observed in the pandemic.
Collapse
Affiliation(s)
- Sanika Ravindra Nishandar
- Department of Mechanical Engineering,
Bourns College of Engineering, University of California, Riverside, CA, USA
| | - Yucheng He
- Department of Mechanical Engineering,
Bourns College of Engineering, University of California, Riverside, CA, USA
| | - Marko Princevac
- Department of Mechanical Engineering,
Bourns College of Engineering, University of California, Riverside, CA, USA
| | - Rufus D Edwards
- Department of Epidemiology, Program in
Public Health, University of California Irvine, CA, USA
| |
Collapse
|
12
|
Shinohara N, Ogata M, Kim H, Kagi N, Tatsu K, Inui F, Naito W. Evaluation of shields and ventilation as a countermeasure to protect bus drivers from infection. ENVIRONMENTAL RESEARCH 2023; 216:114603. [PMID: 36279914 DOI: 10.1016/j.envres.2022.114603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 09/22/2022] [Accepted: 10/13/2022] [Indexed: 06/16/2023]
Abstract
We evaluated the deposition of droplets and droplet nuclei-generated by simulated coughing and talking from three points in a bus-on the driver's face and on surfaces around the driver (e.g., the steering wheel), based on whether countermeasures were taken, and assuming that an infected passenger was talking to the driver. When a shield, such as acrylic boards or polyvinyl chloride (PVC) sheets, was used as the countermeasure, the deposition of artificial droplets (>4 μm), emitted from beside or behind the driver, on his eyes, mouth, and cheeks reduced by two to three orders of magnitude or more. Deposition on the surfaces around the driver was also reduced following the use of shields. For artificial droplet nuclei (1.3 μm of polystyrene latex (PSL)) emitted from atomizers beside the driver, the operation of the ventilation fan (VF) and air conditioner (AC), and defroster (DEF) greatly reduced the driver's exposure, while the use of the shield did not. The infection risk of the driver was estimated through exposure to the virus via transfer to the mucosa via hands or surface-to-finger, direct adhesion on the mucosa, and direct inhalation of droplets and droplet nuclei. This is under the assumption that the droplets and droplet nuclei measured in this study are 40% the diameter of those after immediately leaving the mouth of the infected person and are constant regardless of particle size. When using the shield, total infection risk via droplet, airborne, and contact transmission was decreased by 75.0-99.8%. When the shield was not installed, the infection risk decreased by 9.74-48.7% with the operation of the VF, AC, and/or DEF.
Collapse
Affiliation(s)
- Naohide Shinohara
- National Institute of Advanced Industrial Science and Technology (AIST), 16-1 Onogawa, Tsukuba-shi, Ibaraki, 305-8569, Japan.
| | - Masayuki Ogata
- Tokyo Metropolitan University, 1-1 Minami-Osawa, Hachioji-shi, Tokyo, 192-0397, Japan
| | - Hoon Kim
- National Institute of Public Health, 2-3-6 Minami, Wako-shi, Saitama, 351-0197, Japan
| | - Naoki Kagi
- Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo, 152-8552, Japan
| | - Koichi Tatsu
- National Institute of Advanced Industrial Science and Technology (AIST), 16-1 Onogawa, Tsukuba-shi, Ibaraki, 305-8569, Japan; Isuzu Motors Ltd., 8 Tsuchidana, Fujisawa-shi, Kanagawa, 252-8501, Japan
| | - Fuminori Inui
- National Institute of Advanced Industrial Science and Technology (AIST), 16-1 Onogawa, Tsukuba-shi, Ibaraki, 305-8569, Japan
| | - Wataru Naito
- National Institute of Advanced Industrial Science and Technology (AIST), 16-1 Onogawa, Tsukuba-shi, Ibaraki, 305-8569, Japan
| |
Collapse
|
13
|
Dai H, Zhao B. Association between the infection probability of COVID-19 and ventilation rates: An update for SARS-CoV-2 variants. BUILDING SIMULATION 2023; 16:3-12. [PMID: 36277843 PMCID: PMC9579617 DOI: 10.1007/s12273-022-0952-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 09/23/2022] [Accepted: 10/10/2022] [Indexed: 05/12/2023]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the cause of the current coronavirus disease 2019 (COVID-19) pandemic, is evolving. Thus, the risk of airborne transmission in confined spaces may be higher, and corresponding precautions should be re-appraised. Here, we obtained the quantum generation rate (q) value of three SARS-CoV-2 variants (Alpha, Delta, and Omicron) for the Wells-Riley equation with a reproductive number-based fitted approach and estimated the association between the infection probability and ventilation rates. The q value was 89-165 h-1 for Alpha variant, 312-935 h-1 for Delta variant, and 725-2,345 h-1 for Omicron variant. The ventilation rates increased to ensure an infection probability of less than 1%, and were 8,000-14,000 m3 h-1, 26,000-80,000 m3 h-1, and 64,000-250,000 m3 h-1 per infector for the Alpha, Delta, and Omicron variants, respectively. If the infector and susceptible person wore N95 masks, the required ventilation rates decreased to about 1/100 of the values required without masks, which can be achieved in most typical scenarios. An air purifier was ineffective for reducing transmission when used in scenarios without masks. Preventing prolonged exposure time in confined spaces remains critical in reducing the risk of airborne transmission for highly contagious SARS-CoV-2 variants.
Collapse
Affiliation(s)
- Hui Dai
- Department of Building Science, School of Architecture, Tsinghua University, Beijing, 100084 China
| | - Bin Zhao
- Department of Building Science, School of Architecture, Tsinghua University, Beijing, 100084 China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Tsinghua University, Beijing, 100084 China
| |
Collapse
|
14
|
Oksanen L, Auvinen M, Kuula J, Malmgren R, Romantschuk M, Hyvärinen A, Laitinen S, Maunula L, Sanmark E, Geneid A, Sofieva S, Salokas J, Veskiväli H, Sironen T, Grönholm T, Hellsten A, Atanasova N. Combining Phi6 as a surrogate virus and computational large-eddy simulations to study airborne transmission of SARS-CoV-2 in a restaurant. INDOOR AIR 2022; 32:e13165. [PMID: 36437671 PMCID: PMC10100099 DOI: 10.1111/ina.13165] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 09/30/2022] [Accepted: 10/08/2022] [Indexed: 05/18/2023]
Abstract
COVID-19 has highlighted the need for indoor risk-reduction strategies. Our aim is to provide information about the virus dispersion and attempts to reduce the infection risk. Indoor transmission was studied simulating a dining situation in a restaurant. Aerosolized Phi6 viruses were detected with several methods. The aerosol dispersion was modeled by using the Large-Eddy Simulation (LES) technique. Three risk-reduction strategies were studied: (1) augmenting ventilation with air purifiers, (2) spatial partitioning with dividers, and (3) combination of 1 and 2. In all simulations infectious viruses were detected throughout the space proving the existence long-distance aerosol transmission indoors. Experimental cumulative virus numbers and LES dispersion results were qualitatively similar. The LES results were further utilized to derive the evolution of infection probability. Air purifiers augmenting the effective ventilation rate by 65% reduced the spatially averaged infection probability by 30%-32%. This relative reduction manifests with approximately 15 min lag as aerosol dispersion only gradually reaches the purifier units. Both viral findings and LES results confirm that spatial partitioning has a negligible effect on the mean infection-probability indoors, but may affect the local levels adversely. Exploitation of high-resolution LES jointly with microbiological measurements enables an informative interpretation of the experimental results and facilitates a more complete risk assessment.
Collapse
Affiliation(s)
- Lotta Oksanen
- Department of Otorhinolaryngology and Phoniatrics – Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
| | | | - Joel Kuula
- Finnish Meteorological InstituteHelsinkiFinland
| | - Rasmus Malmgren
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| | - Martin Romantschuk
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiLahtiFinland
| | | | | | - Leena Maunula
- Faculty of Veterinary Medicine, Food Hygiene and Environmental HealthUniversity of HelsinkiHelsinkiFinland
| | - Enni Sanmark
- Department of Otorhinolaryngology and Phoniatrics – Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
| | - Ahmed Geneid
- Department of Otorhinolaryngology and Phoniatrics – Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
| | - Svetlana Sofieva
- Finnish Meteorological InstituteHelsinkiFinland
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| | - Julija Salokas
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| | - Helin Veskiväli
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| | - Tarja Sironen
- Department of Virology, Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Department of Veterinary Biosciences, Faculty of Veterinary MedicineUniversity of HelsinkiHelsinkiFinland
| | | | | | - Nina Atanasova
- Finnish Meteorological InstituteHelsinkiFinland
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| |
Collapse
|
15
|
Aerosol concentrations and size distributions during clinical dental procedures. Heliyon 2022; 8:e11074. [PMID: 36303931 PMCID: PMC9593181 DOI: 10.1016/j.heliyon.2022.e11074] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 09/17/2022] [Accepted: 10/10/2022] [Indexed: 11/05/2022] Open
Abstract
Background Suspected aerosol-generating dental instruments may cause risks for operators by transmitting pathogens, such as the SARS-CoV-2 virus. The aim of our study was to measure aerosol generation in various dental procedures in clinical settings. Methods The study population comprised of 84 patients who underwent 253 different dental procedures measured with Optical Particle Sizer in a dental office setting. Aerosol particles from 0.3 to 10 μm in diameter were measured. Dental procedures included oral examinations (N = 52), restorative procedures with air turbine handpiece (N = 8), high-speed (N = 6) and low-speed (N = 30) handpieces, ultrasonic scaling (N = 31), periodontal treatment using hand instruments (N = 60), endodontic treatment (N = 12), intraoral radiographs (N = 24), and dental local anesthesia (N = 31). Results Air turbine handpieces significantly elevated <1 μm particle median (p = 0.013) and maximum (p = 0.016) aerosol number concentrations as well as aerosol particle mass concentrations (p = 0.046 and p = 0.006) compared to the background aerosol levels preceding the operation. Low-speed dental handpieces elevated >5 μm median (p = 0.023), maximum (p = 0.013) particle number concentrations,> 5 μm particle mass concentrations (p = 0.021) and maximum total particle mass concentrations (p = 0.022). High-speed dental handpieces elevated aerosol concentration levels compared to the levels produced during oral examination. Conclusions Air turbine handpieces produced the highest levels of <1 μm aerosols and total particle number concentrations when compared to the other commonly used instruments. In addition, high- and low-speed dental handpieces and ultrasonic scalers elevated the aerosol concentration levels compared to the aerosol levels measured during oral examination. These aerosol-generating procedures, involving air turbine, high- and low-speed handpiece, and ultrasonic scaler, should be performed with caution. Clinical significance Aerosol generating dental instruments, especially air turbine, should be used with adequate precautions (rubber dam, high-volume evacuation, FFP-respirators), because aerosols can cause a potential risk for operators and substitution of air turbine for high-speed dental handpiece in poor epidemic situations should be considered to reduce the risk of aerosol transmission.
Collapse
|
16
|
Morawska L, Buonanno G, Mikszewski A, Stabile L. The physics of respiratory particle generation, fate in the air, and inhalation. NATURE REVIEWS. PHYSICS 2022; 4:723-734. [PMID: 36065441 PMCID: PMC9430019 DOI: 10.1038/s42254-022-00506-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 08/03/2022] [Indexed: 05/31/2023]
Abstract
Given that breathing is one of the most fundamental physiological functions, there is an urgent need to broaden our understanding of the fluid dynamics that governs it. There would be many benefits from doing so, including a better assessment of respiratory health, a basis for more precise delivery of pharmaceutical drugs for treatment, and the understanding and potential minimization of respiratory infection transmission. We review the physics of particle generation in the respiratory tract, the fate of these particles in the air on exhalation and the physics of particle inhalation. The main focus is on evidence from experimental studies. We conclude that although there is qualitative understanding of the generation of particles in the respiratory tract, a basic quantitative knowledge of the characteristics of the particles emitted during respiratory activities and their fate after emission, and a theoretical understanding of particle deposition during inhalation, nevertheless the general understanding of the entire process is rudimentary, and many open questions remain.
Collapse
Affiliation(s)
- Lidia Morawska
- Queensland University of Technology, International Laboratory for Air Quality & Health (ILAQH), Brisbane, Queensland Australia
- Global Centre for Clean Air Research, Department of Civil and Environmental Engineering, University of Surrey, Guildford, UK
| | - Giorgio Buonanno
- Queensland University of Technology, International Laboratory for Air Quality & Health (ILAQH), Brisbane, Queensland Australia
- Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, Italy
| | - Alex Mikszewski
- Queensland University of Technology, International Laboratory for Air Quality & Health (ILAQH), Brisbane, Queensland Australia
| | - Luca Stabile
- Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, Italy
| |
Collapse
|
17
|
Jimenez JL, Marr LC, Randall K, Ewing ET, Tufekci Z, Greenhalgh T, Tellier R, Tang JW, Li Y, Morawska L, Mesiano‐Crookston J, Fisman D, Hegarty O, Dancer SJ, Bluyssen PM, Buonanno G, Loomans MGLC, Bahnfleth WP, Yao M, Sekhar C, Wargocki P, Melikov AK, Prather KA. What were the historical reasons for the resistance to recognizing airborne transmission during the COVID-19 pandemic? INDOOR AIR 2022; 32:e13070. [PMID: 36040283 PMCID: PMC9538841 DOI: 10.1111/ina.13070] [Citation(s) in RCA: 31] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 05/25/2022] [Accepted: 05/30/2022] [Indexed: 05/05/2023]
Abstract
The question of whether SARS-CoV-2 is mainly transmitted by droplets or aerosols has been highly controversial. We sought to explain this controversy through a historical analysis of transmission research in other diseases. For most of human history, the dominant paradigm was that many diseases were carried by the air, often over long distances and in a phantasmagorical way. This miasmatic paradigm was challenged in the mid to late 19th century with the rise of germ theory, and as diseases such as cholera, puerperal fever, and malaria were found to actually transmit in other ways. Motivated by his views on the importance of contact/droplet infection, and the resistance he encountered from the remaining influence of miasma theory, prominent public health official Charles Chapin in 1910 helped initiate a successful paradigm shift, deeming airborne transmission most unlikely. This new paradigm became dominant. However, the lack of understanding of aerosols led to systematic errors in the interpretation of research evidence on transmission pathways. For the next five decades, airborne transmission was considered of negligible or minor importance for all major respiratory diseases, until a demonstration of airborne transmission of tuberculosis (which had been mistakenly thought to be transmitted by droplets) in 1962. The contact/droplet paradigm remained dominant, and only a few diseases were widely accepted as airborne before COVID-19: those that were clearly transmitted to people not in the same room. The acceleration of interdisciplinary research inspired by the COVID-19 pandemic has shown that airborne transmission is a major mode of transmission for this disease, and is likely to be significant for many respiratory infectious diseases.
Collapse
Affiliation(s)
- Jose L. Jimenez
- Department of Chemistry and Cooperative Institute for Research in Environmental SciencesUniversity of ColoradoBoulderColoradoUSA
| | - Linsey C. Marr
- Department of Civil and Environmental EngineeringVirginia TechBlacksburgVirginiaUSA
| | | | | | - Zeynep Tufekci
- School of JournalismColumbia UniversityNew YorkNew YorkUSA
| | - Trish Greenhalgh
- Department of Primary Care Health SciencesMedical Sciences DivisionUniversity of OxfordOxfordUK
| | | | - Julian W. Tang
- Department of Respiratory SciencesUniversity of LeicesterLeicesterUK
| | - Yuguo Li
- Department of Mechanical EngineeringUniversity of Hong KongHong KongChina
| | - Lidia Morawska
- International Laboratory for Air Quality and HeathQueensland University of TechnologyBrisbaneQueenslandAustralia
| | | | - David Fisman
- Dalla Lana School of Public HealthUniversity of TorontoTorontoOntarioCanada
| | - Orla Hegarty
- School of Architecture, Planning & Environmental PolicyUniversity College DublinDublinIreland
| | - Stephanie J. Dancer
- Department of MicrobiologyHairmyres Hospital, Glasgow, and Edinburgh Napier UniversityGlasgowUK
| | - Philomena M. Bluyssen
- Faculty of Architecture and the Built EnvironmentDelft University of TechnologyDelftThe Netherlands
| | - Giorgio Buonanno
- Department of Civil and Mechanical EngineeringUniversity of Cassino and Southern LazioCassinoItaly
| | - Marcel G. L. C. Loomans
- Department of the Built EnvironmentEindhoven University of Technology (TU/e)EindhovenThe Netherlands
| | - William P. Bahnfleth
- Department of Architectural EngineeringThe Pennsylvania State UniversityUniversity ParkPennsylvaniaUSA
| | - Maosheng Yao
- College of Environmental Sciences and EngineeringPeking UniversityBeijingChina
| | - Chandra Sekhar
- Department of the Built EnvironmentNational University of SingaporeSingaporeSingapore
| | - Pawel Wargocki
- Department of Civil EngineeringTechnical University of DenmarkLyngbyDenmark
| | - Arsen K. Melikov
- Department of Civil EngineeringTechnical University of DenmarkLyngbyDenmark
| | - Kimberly A. Prather
- Scripps Institution of OceanographyUniversity of California San DiegoLa JollaCaliforniaUSA
| |
Collapse
|
18
|
Buonanno G, Robotto A, Brizio E, Morawska L, Civra A, Corino F, Lembo D, Ficco G, Stabile L. Link between SARS-CoV-2 emissions and airborne concentrations: Closing the gap in understanding. JOURNAL OF HAZARDOUS MATERIALS 2022; 428:128279. [PMID: 35063838 PMCID: PMC8760841 DOI: 10.1016/j.jhazmat.2022.128279] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 01/11/2022] [Accepted: 01/12/2022] [Indexed: 05/03/2023]
Abstract
The airborne transmission of SARS-CoV-2 remains surprisingly controversial; indeed, health and regulatory authorities still require direct proof of this mode of transmission. To close this gap, we measured the viral load of SARS-CoV-2 of an infected subject in a hospital room (through an oral and nasopharyngeal swab), as well as the airborne SARS-CoV-2 concentration in the room resulting from the person breathing and speaking. Moreover, we simulated the same scenarios to estimate the concentration of RNA copies in the air through a novel theoretical approach and conducted a comparative analysis between experimental and theoretical results. Results showed that for an infected subject's viral load ranging between 2.4 × 106 and 5.5 × 106 RNA copies mL-1, the corresponding airborne SARS-CoV-2 concentration was below the minimum detection threshold when the person was breathing, and 16.1 (expanded uncertainty of 32.8) RNA copies m-3 when speaking. The application of the predictive approach provided concentrations metrologically compatible with the available experimental data (i.e. for speaking activity). Thus, the study presented significant evidence to close the gap in understanding airborne transmission, given that the airborne SARS-CoV-2 concentration was shown to be directly related to the SARS-CoV-2 emitted. Moreover, the theoretical analysis was shown to be able to quantitatively link the airborne concentration to the emission.
Collapse
Affiliation(s)
- G Buonanno
- Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, FR, Italy; International Laboratory for Air Quality and Health, Queensland University of Technology, Brisbane, Qld, Australia; Infectious Diseases Unit, Department of Medical Sciences, Amedeo di Savoia Hospital, University of Turin, Torino, Italy
| | - A Robotto
- Environmental Protection Agency of Piedmont (ARPA Piemonte), Italy; Infectious Diseases Unit, Department of Medical Sciences, Amedeo di Savoia Hospital, University of Turin, Torino, Italy
| | - E Brizio
- Environmental Protection Agency of Piedmont (ARPA Piemonte), Italy; Infectious Diseases Unit, Department of Medical Sciences, Amedeo di Savoia Hospital, University of Turin, Torino, Italy
| | - L Morawska
- International Laboratory for Air Quality and Health, Queensland University of Technology, Brisbane, Qld, Australia; Infectious Diseases Unit, Department of Medical Sciences, Amedeo di Savoia Hospital, University of Turin, Torino, Italy
| | - A Civra
- Dept. of Clinical and Biological Science, Azienda Ospedaliero-Universitaria San Luigi Gonzaga, University of Turin, Italy; Infectious Diseases Unit, Department of Medical Sciences, Amedeo di Savoia Hospital, University of Turin, Torino, Italy
| | - F Corino
- Environmental Protection Agency of Piedmont (ARPA Piemonte), Italy; Infectious Diseases Unit, Department of Medical Sciences, Amedeo di Savoia Hospital, University of Turin, Torino, Italy
| | - D Lembo
- Dept. of Clinical and Biological Science, Azienda Ospedaliero-Universitaria San Luigi Gonzaga, University of Turin, Italy; Infectious Diseases Unit, Department of Medical Sciences, Amedeo di Savoia Hospital, University of Turin, Torino, Italy
| | - G Ficco
- Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, FR, Italy; Infectious Diseases Unit, Department of Medical Sciences, Amedeo di Savoia Hospital, University of Turin, Torino, Italy
| | - L Stabile
- Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, FR, Italy; Infectious Diseases Unit, Department of Medical Sciences, Amedeo di Savoia Hospital, University of Turin, Torino, Italy.
| |
Collapse
|
19
|
Tellier R. COVID-19: the case for aerosol transmission. Interface Focus 2022; 12:20210072. [PMID: 35261731 PMCID: PMC8831082 DOI: 10.1098/rsfs.2021.0072] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Accepted: 12/06/2021] [Indexed: 01/21/2023] Open
Abstract
The COVID-19 pandemic is the most severe pandemic caused by a respiratory virus since the 1918 influenza pandemic. As is the case with other respiratory viruses, three modes of transmission have been invoked: contact (direct and through fomites), large droplets and aerosols. This narrative review makes the case that aerosol transmission is an important mode for COVID-19, through reviewing studies about bioaerosol physiology, detection of infectious SARS-CoV-2 in exhaled bioaerosols, prolonged SARS-CoV-2 infectivity persistence in aerosols created in the laboratory, detection of SARS-CoV-2 in air samples, investigation of outbreaks with manifest involvement of aerosols, and animal model experiments. SARS-CoV-2 joins influenza A virus as a virus with proven pandemic capacity that can be spread by the aerosol route. This has profound implications for the control of the current pandemic and for future pandemic preparedness.
Collapse
Affiliation(s)
- Raymond Tellier
- Department of Medicine, McGill University, Montreal, Quebec, Canada
| |
Collapse
|
20
|
Oksanen L, Sanmark E, Sofieva S, Rantanen N, Lahelma M, Anttila V, Lehtonen L, Atanasova N, Pesonen E, Geneid A, Hyvärinen A. Aerosol generation during general anesthesia is comparable to coughing: An observational clinical study. Acta Anaesthesiol Scand 2022; 66:463-472. [PMID: 34951703 PMCID: PMC9303240 DOI: 10.1111/aas.14022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 12/13/2021] [Accepted: 12/16/2021] [Indexed: 11/27/2022]
Abstract
BACKGROUND Intubation, laryngoscopy, and extubation are considered highly aerosol-generating procedures, and additional safety protocols are used during COVID-19 pandemic in these procedures. However, previous studies are mainly experimental and have neither analyzed staff exposure to aerosol generation in the real-life operating room environment nor compared the exposure to aerosol concentrations generated during normal patient care. To assess operational staff exposure to potentially infectious particle generation during general anesthesia, we measured particle concentration and size distribution with patients undergoing surgery with Optical Particle Sizer. METHODS A single-center observative multidisciplinary clinical study in Helsinki University Hospital with 39 adult patients who underwent general anesthesia with tracheal intubation. Mean particle concentrations during different anesthesia procedures were statistically compared with cough control data collected from 37 volunteers to assess the differences in particle generation. RESULTS This study measured 25 preoxygenations, 30 mask ventilations, 28 intubations, and 24 extubations. The highest total aerosol concentration of 1153 particles (p)/cm³ was observed during mask ventilation. Preoxygenations, mask ventilations, and extubations as well as uncomplicated intubations generated mean aerosol concentrations statistically comparable to coughing. It is noteworthy that difficult intubation generated significantly fewer aerosols than either uncomplicated intubation (p = .007) or coughing (p = 0.006). CONCLUSIONS Anesthesia induction generates mainly small (<1 µm) aerosol particles. Based on our results, general anesthesia procedures are not highly aerosol-generating compared with coughing. Thus, their definition as high-risk aerosol-generating procedures should be re-evaluated due to comparable exposures during normal patient care. IMPLICATION STATEMENT The list of aerosol-generating procedures guides the use of protective equipments in hospitals. Intubation is listed as a high-risk aerosol-generating procedure, however, aerosol generation has not been measured thoroughly. We measured aerosol generation during general anesthesia. None of the general anesthesia procedures generated statistically more aerosols than coughing and thus should not be considered as higher risk compared to normal respiratory activities.
Collapse
Affiliation(s)
- Lotta‐Maria Oksanen
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Department of Otorhinolaryngology and Phoniatrics—Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
| | - Enni Sanmark
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Department of Otorhinolaryngology and Phoniatrics—Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
| | - Svetlana Sofieva
- Faculty of Biological and Environmental SciencesMolecular and Integrative Biosciences Research ProgrammeUniversity of HelsinkiHelsinkiFinland
| | - Noora Rantanen
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Department of Otorhinolaryngology and Phoniatrics—Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
| | - Mari Lahelma
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Department of Otorhinolaryngology and Phoniatrics—Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
- Faculty of Science, Mathematics and StatisticsUniversity of HelsinkiHelsinkiFinland
| | - Veli‐Jukka Anttila
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- HUS Inflammation CentreHelsinki University HospitalHelsinkiFinland
| | - Lasse Lehtonen
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- HUS Diagnostic CentreHUSLABHelsinki University HospitalHelsinkiFinland
| | - Nina Atanasova
- Faculty of Biological and Environmental SciencesMolecular and Integrative Biosciences Research ProgrammeUniversity of HelsinkiHelsinkiFinland
- Finnish Meteorological InstituteHelsinkiFinland
| | - Eero Pesonen
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Department of Anesthesiology, Intensive Care and Pain MedicineHelsinki University HospitalHelsinkiFinland
| | - Ahmed Geneid
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Department of Otorhinolaryngology and Phoniatrics—Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
| | | |
Collapse
|
21
|
Khursheed R, Paudel KR, Gulati M, Vishwas S, Jha NK, Hansbro PM, Oliver BG, Dua K, Singh SK. Expanding the arsenal against pulmonary diseases using surface-functionalized polymeric micelles: breakthroughs and bottlenecks. Nanomedicine (Lond) 2022; 17:881-911. [PMID: 35332783 DOI: 10.2217/nnm-2021-0451] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Pulmonary diseases such as lung cancer, asthma and tuberculosis have remained one of the common challenges globally. Polymeric micelles (PMs) have emerged as an effective technique for achieving targeted drug delivery for a local as well as a systemic effect. These PMs encapsulate and protect hydrophobic drugs, increase pulmonary targeting, decrease side effects and enhance drug efficacy through the inhalation route. In the current review, emphasis has been placed on the different barriers encountered by the drugs given via the pulmonary route and the mechanism of PMs in achieving drug targeting. The applications of PMs in different pulmonary diseases have also been discussed in detail.
Collapse
Affiliation(s)
- Rubiya Khursheed
- School of Pharmaceutical Sciences, Lovely Professional University, Phagwara, Punjab, 144411, India
| | - Keshav R Paudel
- Centre of Inflammation, Centenary Institute and University of Technology Sydney, Faculty of Science, School of Life Sciences, Sydney, 2007, Australia
| | - Monica Gulati
- School of Pharmaceutical Sciences, Lovely Professional University, Phagwara, Punjab, 144411, India.,Faculty of Health, Australian Research Centre in Complementary & Integrative Medicine, University of Technology Sydney, Ultimo, NSW, 2007, Australia
| | - Sukriti Vishwas
- School of Pharmaceutical Sciences, Lovely Professional University, Phagwara, Punjab, 144411, India
| | - Niraj Kumar Jha
- Department of Biotechnology, School of Engineering & Technology (SET), Sharda University, Plot No. 32-34 Knowledge Park III Greater Noida, Uttar Pradesh, 201310, India
| | - Philip M Hansbro
- Centre of Inflammation, Centenary Institute and University of Technology Sydney, Faculty of Science, School of Life Sciences, Sydney, 2007, Australia
| | - Brian G Oliver
- Woolcock Institute of Medical Research, University of Sydney, Sydney, New South Wales, 2007, Australia.,School of Life Sciences, Faculty of Science, University of Technology Sydney, Sydney 2007, Australia
| | - Kamal Dua
- Faculty of Health, Australian Research Centre in Complementary & Integrative Medicine, University of Technology Sydney, Ultimo, NSW, 2007, Australia.,Discipline of Pharmacy, Graduate School of Health, University of Technology Sydney, Ultimo, NSW, 2007, Australia
| | - Sachin Kumar Singh
- School of Pharmaceutical Sciences, Lovely Professional University, Phagwara, Punjab, 144411, India.,Faculty of Health, Australian Research Centre in Complementary & Integrative Medicine, University of Technology Sydney, Ultimo, NSW, 2007, Australia
| |
Collapse
|
22
|
Bueno de Mesquita PJ, Delp WW, Chan WR, Bahnfleth WP, Singer BC. Control of airborne infectious disease in buildings: Evidence and research priorities. INDOOR AIR 2022; 32:e12965. [PMID: 34816493 DOI: 10.1111/ina.12965] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 10/07/2021] [Accepted: 11/11/2021] [Indexed: 06/13/2023]
Abstract
The evolution of SARS-CoV-2 virus has resulted in variants likely to be more readily transmitted through respiratory aerosols, underscoring the increased potential for indoor environmental controls to mitigate risk. Use of tight-fitting face masks to trap infectious aerosol in exhaled breath and reduce inhalation exposure to contaminated air is of critical importance for disease control. Administrative controls including the regulation of occupancy and interpersonal spacing are also important, while presenting social and economic challenges. Indoor engineering controls including ventilation, exhaust, air flow control, filtration, and disinfection by germicidal ultraviolet irradiation can reduce reliance on stringent occupancy restrictions. However, the effects of controls-individually and in combination-on reducing infectious aerosol transfer indoors remain to be clearly characterized to the extent needed to support widespread implementation by building operators. We review aerobiologic and epidemiologic evidence of indoor environmental controls against transmission and present a quantitative aerosol transfer scenario illustrating relative differences in exposure at close-interactive, room, and building scales. We identify an overarching need for investment to implement building controls and evaluate their effectiveness on infection in well-characterized and real-world settings, supported by specific, methodological advances. Improved understanding of engineering control effectiveness guides implementation at scale while considering occupant comfort, operational challenges, and energy costs.
Collapse
Affiliation(s)
| | - William W Delp
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - Wanyu R Chan
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - William P Bahnfleth
- Department of Architectural Engineering, Pennsylvania State University, State College, Pennsylvania, USA
| | - Brett C Singer
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| |
Collapse
|