1
|
Wang X, Liu W, Luo Q, Yao L, Wei F. Thermally Drawn-Based Microtubule Soft Continuum Robot for Cardiovascular Intervention. ACS APPLIED MATERIALS & INTERFACES 2024; 16:29783-29792. [PMID: 38811019 DOI: 10.1021/acsami.4c03885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2024]
Abstract
Cardiovascular disease is becoming the leading cause of human mortality. In order to address this, flexible continuum robots have emerged as a promising solution for miniaturizing and automating vascular interventional equipment for diagnosing and treating cardiovascular diseases. However, existing continuum robots used for vascular intervention face challenges such as large cross-sectional sizes, inadequate driving force, and lack of navigation control, preventing them from accessing cerebral blood vessels or capillaries for medical procedures. Additionally, the complex manufacturing process and high cost of soft continuum robots hinder their widespread clinical application. In this study, we propose a thermally drawn-based microtubule soft continuum robot that overcomes these limitations. The proposed robot has cross-sectional dimensions several orders of magnitude smaller than the smallest commercially available conduits, and it can be manufactured without any length restrictions. By utilizing a driving strategy based on liquid kinetic energy advancement and external magnetic field for steering, the robot can easily navigate within blood vessels and accurately reach the site of the lesion. This innovation holds the potential to achieve controlled navigation of the robot throughout the entire blood vessel, enabling in situ diagnosis and treatment of cardiovascular diseases.
Collapse
Affiliation(s)
- Xufeng Wang
- School of Mechanical Engineering and Automation, Fuzhou University, Minhou County, Fuzhou, Fujian 350108, China
| | - Wei Liu
- School of Mechanical Engineering and Automation, Fuzhou University, Minhou County, Fuzhou, Fujian 350108, China
| | - Qinzhou Luo
- School of Mechanical Engineering and Automation, Fuzhou University, Minhou County, Fuzhou, Fujian 350108, China
| | - Ligang Yao
- School of Mechanical Engineering and Automation, Fuzhou University, Minhou County, Fuzhou, Fujian 350108, China
| | - Fanan Wei
- School of Mechanical Engineering and Automation, Fuzhou University, Minhou County, Fuzhou, Fujian 350108, China
| |
Collapse
|
2
|
Sakuta K, Imahori T, Molaie A, Ghovvati M, Rao N, Tateshima S, Kaneko N. Water content for clot composition prediction in acute ischemic stroke. PLoS One 2024; 19:e0304520. [PMID: 38787842 PMCID: PMC11125472 DOI: 10.1371/journal.pone.0304520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Accepted: 05/14/2024] [Indexed: 05/26/2024] Open
Abstract
BACKGROUND Mechanical thrombectomy (MT) has become the gold standard care for treating acute ischemic stroke (AIS) due to large vessel occlusion. Emerging evidence suggests that understanding the composition of clots prior to intervention could be useful for the selection of neuroendovascular techniques, potentially improving the efficacy of treatments. However, current imaging modalities lack the ability to distinguish clot composition accurately and reliably. Since water content can influence signal intensity on CT and MRI scans, its assessment may provide indirect clues about clot composition. This study aimed to elucidate the correlation between water content and clot composition using human clots retrieved from stroke patients and experimentally generated ovine clots. MATERIALS AND METHODS This study involved an analysis of ten clots retrieved from patients with AIS undergoing MT. Additionally, we created ten red blood cells (RBC)-rich and ten fibrin-rich ovine blood clots, which were placed in a human intracranial vascular model under realistic flow conditions. The water content and compositions of these clots were evaluated, and linear regression analyses were performed to determine the relationship between clot composition and water content. RESULTS The regression analysis in human stroke clots revealed a significant negative association between RBC concentration and water content. We also observed a positive correlation between water content and both fibrin and platelets in ovine blood clots. Conclusion.
Collapse
Affiliation(s)
- Kenichi Sakuta
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States of America
- Department of Neurology, Jikei University School of Medicine, Tokyo, Japan
- Department of Neurology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States of America
| | - Taichiro Imahori
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States of America
- Department of Neurosurgery, Kitaharima Medical Center, Hyogo, Japan
| | - Amir Molaie
- Department of Neurology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States of America
| | - Mahsa Ghovvati
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States of America
| | - Neal Rao
- Department of Neurology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States of America
| | - Satoshi Tateshima
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States of America
| | - Naoki Kaneko
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States of America
| |
Collapse
|
3
|
Schoenborn S, Lorenz T, Kuo K, Fletcher DF, Woodruff MA, Pirola S, Allenby MC. Fluid-structure interactions of peripheral arteries using a coupled in silico and in vitro approach. Comput Biol Med 2023; 165:107474. [PMID: 37703711 DOI: 10.1016/j.compbiomed.2023.107474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 08/21/2023] [Accepted: 09/04/2023] [Indexed: 09/15/2023]
Abstract
Vascular compliance is considered both a cause and a consequence of cardiovascular disease and a significant factor in the mid- and long-term patency of vascular grafts. However, the biomechanical effects of localised changes in compliance cannot be satisfactorily studied with the available medical imaging technologies or surgical simulation materials. To address this unmet need, we developed a coupled silico-vitro platform which allows for the validation of numerical fluid-structure interaction results as a numerical model and physical prototype. This numerical one-way and two-way fluid-structure interaction study is based on a three-dimensional computer model of an idealised femoral artery which is validated against patient measurements derived from the literature. The numerical results are then compared with experimental values collected from compliant arterial phantoms via direct pressurisation and ring tensile testing. Phantoms within a compliance range of 1.4-68.0%/100 mmHg were fabricated via additive manufacturing and silicone casting, then mechanically characterised via ring tensile testing and optical analysis under direct pressurisation with moderately statistically significant differences in measured compliance ranging between 10 and 20% for the two methods. One-way fluid-structure interaction coupling underestimated arterial wall compliance by up to 14.7% compared with two-way coupled models. Overall, Solaris™ (Smooth-On) matched the compliance range of the numerical and in vivo patient models most closely out of the tested silicone materials. Our approach is promising for vascular applications where mechanical compliance is especially important, such as the study of diseases which commonly affect arterial wall stiffness, such as atherosclerosis, and the model-based design, surgical training, and optimisation of vascular prostheses.
Collapse
Affiliation(s)
- S Schoenborn
- BioMimetic Systems Engineering (BMSE) Lab, School of Chemical Engineering, University of Queensland (UQ), St Lucia, QLD, 4072, Australia; Biofabrication and Tissue Morphology (BTM) Group, Faculty of Engineering, Centre for Biomedical Technologies, Queensland University of Technology (QUT), Kelvin Grove, QLD, 4059, Australia
| | - T Lorenz
- Institute of Textile Technology, RWTH Aachen University, 52074, Aachen, Germany
| | - K Kuo
- Institute of Textile Technology, RWTH Aachen University, 52074, Aachen, Germany
| | - D F Fletcher
- School of Chemical and Biomolecular Engineering, University of Sydney, Darlington, NSW, 2006, Australia
| | - M A Woodruff
- Biofabrication and Tissue Morphology (BTM) Group, Faculty of Engineering, Centre for Biomedical Technologies, Queensland University of Technology (QUT), Kelvin Grove, QLD, 4059, Australia
| | - S Pirola
- BHF Centre of Research Excellence, Faculty of Medicine, Institute of Clinical Sciences, Imperial College London, South Kensington Campus, London, SW7 2AZ, United Kingdom; Department of Biomechanical Engineering, Faculty of Mechanical Engineering (3me), Delft University of Technology (TUD), Delft, the Netherlands
| | - M C Allenby
- BioMimetic Systems Engineering (BMSE) Lab, School of Chemical Engineering, University of Queensland (UQ), St Lucia, QLD, 4072, Australia; Biofabrication and Tissue Morphology (BTM) Group, Faculty of Engineering, Centre for Biomedical Technologies, Queensland University of Technology (QUT), Kelvin Grove, QLD, 4059, Australia.
| |
Collapse
|
4
|
Mechanical Properties of a 3 Dimensional-Printed Transparent Flexible Resin Used for Vascular Model Simulation Compared with Those of Porcine Arteries. J Vasc Interv Radiol 2023; 34:871-878.e3. [PMID: 36646207 DOI: 10.1016/j.jvir.2023.01.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 12/21/2022] [Accepted: 01/06/2023] [Indexed: 01/15/2023] Open
Abstract
PURPOSE To develop a vascular intervention simulation model that replicates the characteristics of a human patient and to compare the mechanical properties of a 3-dimensional (3D)-printed transparent flexible resin with those of porcine arteries using the elastic modulus (E) and kinetic friction coefficient (μk). MATERIALS AND METHODS Resin plates were created from a transparent flexible resin using a 3D printer. Porcine artery plates were prepared by excising the aorta. E values and the adhesive strengths of the resin and arterial surfaces toward a polyethylene plate, were measured with a tensile-compressive mechanical tester. Resin transparency was measured using an ultraviolet-visible light spectrometer. The μk value of the resin plate surface after applying silicone spray for 1-5 seconds and that of the artery were measured using a translational friction tester. RESULTS E values differed significantly between the arteries and resin plates at each curing time (0.20 MPa ± 0.04 vs 8.53 MPa ± 2.37 for a curing time of 1 minute; P < .05). The resin was stiffer than the arteries, regardless of the curing times. The visible light transmittance and adhesive strength of the resin decreased as the curing time increased. The adhesive strength of the artery was the lowest. The μk value of the silicone-coated resin surface created by applying silicone for 2-3 seconds (thickness of the silicone layer, 1.6-2.0 μm) was comparable with that of the artery, indicating that the coating imparted a similar slippage to the resin as to the living artery. CONCLUSIONS A transparent flexible resin is useful for creating a transparent and slippery vascular model for vascular intervention simulation.
Collapse
|
5
|
Johnson S, Dwivedi A, Mirza M, McCarthy R, Gilvarry M. A Review of the Advancements in the in-vitro Modelling of Acute Ischemic Stroke and Its Treatment. FRONTIERS IN MEDICAL TECHNOLOGY 2022; 4:879074. [PMID: 35756535 PMCID: PMC9214215 DOI: 10.3389/fmedt.2022.879074] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 04/29/2022] [Indexed: 11/13/2022] Open
Abstract
In-vitro neurovascular models of large vessel occlusions (LVOs) causing acute ischemic stroke (AIS) are used extensively for pre-clinical testing of new treatment devices. They enable physicians and engineers to examine device performance and the response of the occlusion to further advance design solutions for current unmet clinical needs. These models also enable physicians to train on basic skills, to try out new devices and new procedural approaches, and for the stroke team to practice workflows together in the comfort of a controlled environment in a non-clinical setting. Removal of the occlusive clot in its entirety is the primary goal of the endovascular treatment of LVOs via mechanical thrombectomy (MT) and the medical treatment via thrombolysis. In MT, recanalization after just one pass is associated with better clinical outcomes than procedures that take multiple passes to achieve the same level of recanalization, commonly known as first pass effect (FPE). To achieve this, physicians and engineers are continually investigating new devices and treatment approaches. To distinguish between treatment devices in the pre-clinical setting, test models must also be optimized and expanded become more nuanced and to represent challenging patient cohorts that could be improved through new technology or better techniques. The aim of this paper is to provide a perspective review of the recent advancements in the in-vitro modeling of stroke and to outline how these models need to advance further in future. This review provides an overview of the various in-vitro models used for the modeling of AIS and compares the advantages and limitations of each. In-vitro models remain an extremely useful tool in the evaluation and design of treatment devices, and great strides have been made to improve replication of physiological conditions. However, further advancement is still required to represent the expanding indications for thrombectomy and thrombolysis, and the generation of new thrombectomy devices, to ensure that smaller treatment effects are captured.
Collapse
Affiliation(s)
- Sarah Johnson
- Cerenovus (Johnson & Johnson), Galway Neuro Technology Centre, Galway, Ireland
| | | | | | | | | |
Collapse
|
6
|
Preclinical modeling of mechanical thrombectomy. J Biomech 2021; 130:110894. [PMID: 34915309 DOI: 10.1016/j.jbiomech.2021.110894] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 11/16/2021] [Accepted: 11/18/2021] [Indexed: 11/21/2022]
Abstract
Mechanical thrombectomy to treat large vessel occlusions (LVO) causing a stroke is one of the most effective treatments in medicine, with a number needed to treat to improve clinical outcomes as low as 2.6. As the name implies, it is a mechanical solution to a blocked artery and modeling these mechanics preclinically for device design, regulatory clearance and high-fidelity physician training made clinical applications possible. In vitro simulation of LVO is extensively used to characterize device performance in representative vascular anatomies with physiologically accurate hemodynamics. Embolus analogues, validated against clots extracted from patients, provide a realistic simulated use experience. In vitro experimentation produces quantitative results such as particle analysis of distal emboli generated during the procedure, as well as pressure and flow throughout the experiment. Animal modeling, used mostly for regulatory review, allows estimation of device safety. Other than one recent development, nearly all animal modeling does not incorporate the desired target organ, the brain, but rather is performed in the extracranial circulation. Computational modeling of the procedure remains at the earliest stages but represents an enormous opportunity to rapidly characterize and iterate new thrombectomy concepts as well as optimize procedure workflow. No preclinical model is a perfect surrogate; however, models available can answer important questions during device development and have to date been successful in delivering efficacious and safe devices producing excellent clinical outcomes. This review reflects on the developments of preclinical modeling of mechanical thrombectomy with particular focus on clinical translation, as well as articulate existing gaps requiring additional research.
Collapse
|
7
|
A new method of intracranial aneurysm modeling for stereolithography apparatus 3D printer: the "Wall-carving technique" using digital imaging and communications in medicine data. World Neurosurg 2021; 159:e113-e119. [PMID: 34896354 DOI: 10.1016/j.wneu.2021.12.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 12/03/2021] [Accepted: 12/03/2021] [Indexed: 11/22/2022]
Abstract
PURPOSE To assess the ability of the "wall-carving (WC) image technique," which uses vascular images from three-dimensional digital subtraction angiograms (3DDSAs). Also, to verify the accuracy of the resulting 3D-printed hollow models of intracranial aneurysms. METHODS The 3DDSA data from nine aneurysms were processed to obtain volumetric models suitable for the stereolithography apparatus. The resulting models were filled with iodinated contrast media. 3D rotational angiography of the models was carried out, and the aneurysm geometry was compared with the original patient data. The accuracy of the 3D-printed hollow models' sizes and shapes was evaluated using the nonparametric Wilcoxon signed-rank test and the Dice coefficient index. RESULTS The aneurysm volumes ranged from 34.1 to 4609.8 mm3 (maximum diameters 5.1-30.1 mm), and no statistically significant differences were noted between the patient data and the 3D-printed models (p = 0.4). Shape analysis of the aneurysms and related arteries indicated a high level of accuracy (Dice coefficient index value, 88.7-97.3%; mean [± standard deviation (SD)], 93.6% ± 2.5%). The vessel wall thickness of the 3D-printed hollow models was 0.4 mm for the parent and 0.2 mm for small branches and aneurysms, almost the same as the patient data. CONCLUSION The WC technique, which involves volume rendering of 3DDSAs, can provide a detailed description of the contrast enhancement of intracranial vessels and aneurysms at arbitrary depths. These models can provide precise anatomic information and be used for simulations of endovascular treatment.
Collapse
|
8
|
Yong KW, Janmaleki M, Pachenari M, Mitha AP, Sanati-Nezhad A, Sen A. Engineering a 3D human intracranial aneurysm model using liquid-assisted injection molding and tuned hydrogels. Acta Biomater 2021; 136:266-278. [PMID: 34547516 DOI: 10.1016/j.actbio.2021.09.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 09/14/2021] [Accepted: 09/14/2021] [Indexed: 12/30/2022]
Abstract
Physiologically relevant intracranial aneurysm (IA) models are crucially required to facilitate testing treatment options for IA. Herein, we report the development of a new in vitro tissue-engineered platform, which recapitulates the microenvironment, structure, and cellular complexity of native human IA. A new modified liquid-assisted injection molding technique was developed to fabricate a three-dimensional hollow IA model with clinically relevant IA dimensions within a mechanically tuned Gelatin Methacryloyl (GelMA) hydrogel. An endothelium lining was created inside the IA model by culturing human umbilical vein endothelial cells over pre-cultured human brain vascular smooth muscle cells. These cellularized IA models were subjected to medium perfusion at flow rates between 6.3 and 15.75 mL/min for inducing biomimetic vessel wall shear stress (10-25 dyn/cm2) to the cells for ten days. Both cell types maintained their secretome profiles and showed more than 96% viability, demonstrating the biocompatibility of the hydrogel during perfusion cell culture at such flow rates. Based on the characterized viscoelastic properties of the GelMA hydrogel and with the aid of a fluid-structure interaction model, the capability of the IA model in predicting the response of the IA to different fluid flow profiles was mathematically shown. With physiologically relevant behavior, our developed in vitro human IA model could allow researchers to better understand the pathophysiology and treatment of IA. STATEMENT OF SIGNIFICANCE: A three-dimensional intracranial aneurysm (IA) tissue model recapitulating the microenvironment, structure, and cellular complexity of native human IA was developed. • An endothelium lining was created inside the IA model over pre-cultured human brain vascular smooth muscle cells over at least 10-day successful culture. • The cells maintained their secretome profiles, demonstrating the biocompatibility of hydrogel during a long-term perfusion cell culture. • The IA model showed its capability in predicting the response of IA to different fluid flow profiles. • The cells in the vessel region behaved differently from cells in the aneurysm region due to alteration in hemodynamic shear stress. • The IA model could allow researchers to better understand the pathophysiology and treatment options of IA.
Collapse
|
9
|
Pravdivtseva MS, Peschke E, Lindner T, Wodarg F, Hensler J, Gabbert D, Voges I, Berg P, Barker AJ, Jansen O, Hövener JB. 3D-printed, patient-specific intracranial aneurysm models: From clinical data to flow experiments with endovascular devices. Med Phys 2021; 48:1469-1484. [PMID: 33428778 DOI: 10.1002/mp.14714] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Revised: 12/30/2020] [Accepted: 12/31/2020] [Indexed: 12/14/2022] Open
Abstract
PURPOSE Flow models of intracranial aneurysms (IAs) can be used to test new and existing endovascular treatments with flow modulation devices (FMDs). Additionally, 4D flow magnetic resonance imaging (MRI) offers the ability to measure hemodynamics. This way, the effect of FMDs can be determined noninvasively and compared to patient data. Here, we describe a cost-effective method for producing flow models to test the efficiency of FMDs with 4D flow MRI. METHODS The models were based on human radiological data (internal carotid and basilar arteries) and printed in 3D with stereolithography. The models were printed with three different printing layers (25, 50, and 100 µm thickness). To evaluate the models in vitro, 3D rotational angiography, time-of-flight MRI, and 4D flow MRI were employed. The flow and geometry of one model were compared with in vivo data. Two FMDs (FMD1 and FMD2) were deployed into two different IA models, and the effect on the flow was estimated by 4D flow MRI. RESULTS Models printed with different layer thicknesses exhibited similar flow and little geometric variation. The mean spatial difference between the vessel geometry measured in vivo and in vitro was 0.7 ± 1.1 mm. The main flow features, such as vortices in the IAs, were reproduced. The velocities in the aneurysms were similar in vivo and in vitro (mean velocity magnitude: 5.4 ± 7.6 and 7.7 ± 8.6 cm/s, maximum velocity magnitude: 72.5 and 55.1 cm/s). By deploying FMDs, the mean velocity was reduced in the IAs (from 8.3 ± 10 to 4.3 ± 9.32 cm/s for FMD1 and 9.9 ± 12.1 to 2.1 ± 5.6 cm/s for FMD2). CONCLUSIONS The presented method allows to produce neurovascular models in approx. 15 to 30 h. The resulting models were found to be geometrically accurate, reproducing the main flow patterns, and suitable for implanting FMDs as well as 4D flow MRI.
Collapse
Affiliation(s)
- Mariya S Pravdivtseva
- Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel, Germany.,Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany.,University of Kiel, Kiel, Germany
| | - Eva Peschke
- Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel, Germany.,Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany.,University of Kiel, Kiel, Germany
| | - Thomas Lindner
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany.,Department of Diagnostic and Interventional Neuroradiology, University Hospital Hamburg-Eppendorf, Hamburg, Germany
| | - Fritz Wodarg
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany
| | - Johannes Hensler
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany
| | - Dominik Gabbert
- Department of Congenital Heart Disease and Pediatric Cardiology, University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany
| | - Inga Voges
- Department of Congenital Heart Disease and Pediatric Cardiology, University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany
| | - Philipp Berg
- Department of Fluid Dynamics and Technical Flows, University of Magdeburg, Magdeburg, Germany.,Research Campus STIMULATE, University of Magdeburg, Magdeburg, Germany
| | - Alex J Barker
- Department of Radiology, University of Colorado Anschutz Medical Campus, Aurora, CO, USA
| | - Olav Jansen
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany
| | - Jan-Bernd Hövener
- Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel, Germany.,Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany.,University of Kiel, Kiel, Germany
| |
Collapse
|
10
|
Onda T, Nonaka T, Nomura T, Inamura S, Honda O, Daibou M. Usefulness of Preoperative Simulation Using a Stereolithographic 3D Printer in Cerebral Aneurysm Coil Embolization. JOURNAL OF NEUROENDOVASCULAR THERAPY 2021; 15:736-740. [PMID: 37502266 PMCID: PMC10371000 DOI: 10.5797/jnet.tn.2020-0151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 01/17/2021] [Indexed: 07/29/2023]
Abstract
Objective We present a preoperative simulation of cerebral aneurysm coil embolization using a hollow model of cerebral blood vessels created by a stereolithography (SLA) 3D printer. Case Presentation The patient was a 66-year-old woman. During follow-up, coil embolization was planned for an expanding paraclinoid aneurysm. A hollow cerebral vascular model was created preoperatively using an SLA 3D printer. The catheter was malleable and inserted into the hollow model, which enabled the surgeons to confirm its movement, stability, and ease of insertion. In the surgical procedure, the catheter was easily inserted into the aneurysm without reshaping. The procedure was completed without stability problems. Conclusion The use of a hollow model of cerebral blood vessels was useful as a preoperative simulation and improved the safety of the procedure.
Collapse
Affiliation(s)
- Toshiyuki Onda
- Department of Neurosurgery, Sapporo Shiroishi Memorial Hospital, Sapporo, Hokkaido, Japan
| | - Tadashi Nonaka
- Department of Neurosurgery, Sapporo Shiroishi Memorial Hospital, Sapporo, Hokkaido, Japan
| | - Tatsufumi Nomura
- Department of Neurosurgery, Sapporo Shiroishi Memorial Hospital, Sapporo, Hokkaido, Japan
| | - Shigeru Inamura
- Department of Neurosurgery, Sapporo Shiroishi Memorial Hospital, Sapporo, Hokkaido, Japan
| | - Osamu Honda
- Department of Neurosurgery, Sapporo Shiroishi Memorial Hospital, Sapporo, Hokkaido, Japan
| | - Masahiko Daibou
- Department of Neurosurgery, Sapporo Shiroishi Memorial Hospital, Sapporo, Hokkaido, Japan
| |
Collapse
|
11
|
Poupart O, Conti R, Schmocker A, Pancaldi L, Moser C, Nuss KM, Sakar MS, Dobrocky T, Grützmacher H, Mosimann PJ, Pioletti DP. Pulsatile Flow-Induced Fatigue-Resistant Photopolymerizable Hydrogels for the Treatment of Intracranial Aneurysms. Front Bioeng Biotechnol 2021; 8:619858. [PMID: 33553124 PMCID: PMC7855579 DOI: 10.3389/fbioe.2020.619858] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Accepted: 12/22/2020] [Indexed: 11/13/2022] Open
Abstract
An alternative intracranial aneurysm embolic agent is emerging in the form of hydrogels due to their ability to be injected in liquid phase and solidify in situ. Hydrogels have the ability to fill an aneurysm sac more completely compared to solid implants such as those used in coil embolization. Recently, the feasibility to implement photopolymerizable poly(ethylene glycol) dimethacrylate (PEGDMA) hydrogels in vitro has been demonstrated for aneurysm application. Nonetheless, the physical and mechanical properties of such hydrogels require further characterization to evaluate their long-term integrity and stability to avoid implant compaction and aneurysm recurrence over time. To that end, molecular weight and polymer content of the hydrogels were tuned to match the elastic modulus and compliance of aneurysmal tissue while minimizing the swelling volume and pressure. The hydrogel precursor was injected and photopolymerized in an in vitro aneurysm model, designed by casting polydimethylsiloxane (PDMS) around 3D printed water-soluble sacrificial molds. The hydrogels were then exposed to a fatigue test under physiological pulsatile flow, inducing a combination of circumferential and shear stresses. The hydrogels withstood 5.5 million cycles and no significant weight loss of the implant was observed nor did the polymerized hydrogel protrude or migrate into the parent artery. Slight surface erosion defects of 2–10 μm in depth were observed after loading compared to 2 μm maximum for non-loaded hydrogels. These results show that our fine-tuned photopolymerized hydrogel is expected to withstand the physiological conditions of an in vivo implant study.
Collapse
Affiliation(s)
- Oriane Poupart
- Laboratory of Biomechanical Orthopedics, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Riccardo Conti
- Department of Chemistry and Applied Biosciences, Swiss Federal Institute of Technology, Zurich, Switzerland
| | - Andreas Schmocker
- Department of Chemistry and Applied Biosciences, Swiss Federal Institute of Technology, Zurich, Switzerland.,Laboratory of Applied Photonics Devices, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.,Institute of Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Lucio Pancaldi
- Institute of Mechanical Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Christophe Moser
- Laboratory of Applied Photonics Devices, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Katja M Nuss
- Musculoskeletal Research Unit, Department of Molecular Mechanisms of Disease, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Mahmut S Sakar
- Institute of Mechanical Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Tomas Dobrocky
- Institute of Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Hansjörg Grützmacher
- Department of Chemistry and Applied Biosciences, Swiss Federal Institute of Technology, Zurich, Switzerland
| | - Pascal J Mosimann
- Institute of Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, Bern, Switzerland.,Department of Diagnostic and Interventional Neuroradiology, Alfried Krupp Hospital, Essen, Germany
| | - Dominique P Pioletti
- Laboratory of Biomechanical Orthopedics, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| |
Collapse
|
12
|
Waqas M, Mokin M, Lim J, Vakharia K, Springer ME, Meess KM, Ducharme RW, Ionita CN, Nagesh SVS, Gutierrez LC, Snyder KV, Davies JM, Levy EI, Siddiqui AH. Design and Physical Properties of 3-Dimensional Printed Models Used for Neurointervention: A Systematic Review of the Literature. Neurosurgery 2021; 87:E445-E453. [PMID: 32392300 DOI: 10.1093/neuros/nyaa134] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Accepted: 03/11/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Three-dimensional (3D) printing has revolutionized training, education, and device testing. Understanding the design and physical properties of 3D-printed models is important. OBJECTIVE To systematically review the design, physical properties, accuracy, and experimental outcomes of 3D-printed vascular models used in neurointervention. METHODS We conducted a systematic review of the literature between January 1, 2000 and September 30, 2018. Public/Publisher MEDLINE (PubMed), Web of Science, Compendex, Cochrane, and Inspec databases were searched using Medical Subject Heading terms for design and physical attributes of 3D-printed models for neurointervention. Information on design and physical properties like compliance, lubricity, flow system, accuracy, and outcome measures were collected. RESULTS A total of 23 articles were included. Nine studies described 3D-printed models for stroke intervention. Tango Plus (Stratasys) was the most common material used to develop these models. Four studies described a population-representative geometry model. All other studies reported patient-specific vascular geometry. Eight studies reported complete reconstruction of the circle of Willis, anterior, and posterior circulation. Four studies reported a model with extracranial vasculature. One prototype study reported compliance and lubricity. Reported circulation systems included manual flushing, programmable pistons, peristaltic, and pulsatile pumps. Outcomes included thrombolysis in cerebral infarction, post-thrombectomy flow restoration, surgical performance, and qualitative feedback. CONCLUSION Variations exist in the material, design, and extent of reconstruction of vasculature of 3D-printed models. There is a need for objective characterization of 3D-printed vascular models. We propose the development of population representative 3D-printed models for skill improvement or device testing.
Collapse
Affiliation(s)
- Muhammad Waqas
- Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York.,Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York
| | - Maxim Mokin
- Department of Neurosurgery and Brain Repair, University of South Florida, Tampa, Florida
| | - Jaims Lim
- Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York.,Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York
| | - Kunal Vakharia
- Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York.,Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York
| | | | | | | | - Ciprian N Ionita
- Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, New York
| | - Swetadri Vasan Setlur Nagesh
- Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York.,Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, New York
| | - Liza C Gutierrez
- Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, New York
| | - Kenneth V Snyder
- Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York.,Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York
| | - Jason M Davies
- Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York.,Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York.,Jacobs Institute, Buffalo, New York.,Department of Bioinformatics, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York
| | - Elad I Levy
- Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York.,Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York.,Jacobs Institute, Buffalo, New York.,Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, New York
| | - Adnan H Siddiqui
- Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York.,Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York.,Jacobs Institute, Buffalo, New York.,Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, New York.,Department of Radiology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York
| |
Collapse
|
13
|
Greenwood TE, Hatch SE, Colton MB, Thomson SL. 3D Printing Low-Stiffness Silicone Within a Curable Support Matrix. ADDITIVE MANUFACTURING 2021; 37:101681. [PMID: 33718006 PMCID: PMC7946128 DOI: 10.1016/j.addma.2020.101681] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Embedded 3D printing processes involve extruding ink within a support matrix that supports the ink throughout printing and curing. In once class of embedded 3D printing, which we refer to as "removable embedded 3D printing," curable inks are printed, cured, then removed from the uncured support matrix. Removable embedded 3D printing is advantageous because low-viscosity inks can be patterned in freeform geometries which may not be feasible to create via casting and other printing processes. When printing solid-infill geometries, however, uncured support matrix becomes trapped within the prints, which may be undesirable. This study builds on previous work by formulating a support matrix for removable embedded 3D printing that cures when mixed with the printed silicone ink to solve the problem of trapped, uncured support matrix within solid-infill prints. Printed specimens are shown to have a nearly isotropic elastic modulus in directions perpendicular and parallel to the printed layers, and a decreased modulus and increased elongation at break compared to specimens cast from the ink. The rheological properties of the support matrix are reported. The capabilities of the printer and support matrix are demonstrated by printing a variety of geometries from four UV and addition-cure silicone inks. Shapes printed with these inks range by nearly two orders of magnitude in stiffness and have failure strains between approximately 50 and 250%, suggesting a wide range of potential applications for this printing process.
Collapse
Affiliation(s)
- Taylor E Greenwood
- Department of Mechanical Engineering, Brigham Young University, Provo, UT, 84602, USA
| | - Serah E Hatch
- Department of Mechanical Engineering, Brigham Young University, Provo, UT, 84602, USA
| | - Mark B Colton
- Department of Mechanical Engineering, Brigham Young University, Provo, UT, 84602, USA
| | - Scott L Thomson
- Department of Mechanical Engineering, Brigham Young University, Provo, UT, 84602, USA
| |
Collapse
|
14
|
Kaneko N, Satta S, Komuro Y, Muthukrishnan SD, Kakarla V, Guo L, An J, Elahi F, Kornblum HI, Liebeskind DS, Hsiai T, Hinman JD. Flow-Mediated Susceptibility and Molecular Response of Cerebral Endothelia to SARS-CoV-2 Infection. Stroke 2021; 52:260-270. [PMID: 33161843 PMCID: PMC7769899 DOI: 10.1161/strokeaha.120.032764] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND AND PURPOSE Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection is associated with an increased rate of cerebrovascular events including ischemic stroke and intracerebral hemorrhage. The mechanisms underlying cerebral endothelial susceptibility and response to SARS-CoV-2 are unknown yet critical to understanding the association of SARS-CoV-2 infection with cerebrovascular events. METHODS Endothelial cells were isolated from human brain and analyzed by RNA sequencing. Human umbilical vein and human brain microvascular cells were used in both monolayer culture and endothelialized within a 3-dimensional printed vascular model of the middle cerebral artery. Gene expression levels were measured by quantitative polymerase chain reaction and direct RNA hybridization. Recombinant SARS-CoV-2 S protein and S protein-containing liposomes were used to measure endothelial binding by immunocytochemistry. RESULTS ACE2 (angiotensin-converting enzyme-2) mRNA levels were low in human brain and monolayer endothelial cell culture. Within the 3-dimensional printed vascular model, ACE2 gene expression and protein levels were progressively increased by vessel size and flow rates. SARS-CoV-2 S protein-containing liposomes were detected in human umbilical vein endothelial cells and human brain microvascular endothelial cells in 3-dimensional middle cerebral artery models but not in monolayer culture consistent with flow dependency of ACE2 expression. Binding of SARS-CoV-2 S protein triggered 83 unique genes in human brain endothelial cells including upregulation of complement component C3. CONCLUSIONS Brain endothelial cells are susceptible to direct SARS-CoV-2 infection through flow-dependent expression of ACE2. Viral S protein binding triggers a unique gene expression profile in brain endothelia that may explain the association of SARS-CoV-2 infection with cerebrovascular events.
Collapse
Affiliation(s)
- Naoki Kaneko
- Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles
| | - Sandro Satta
- Department of Medicine, David Geffen School of Medicine, University of California Los Angeles
| | - Yutaro Komuro
- Department of Neurology, David Geffen School of Medicine, University of California Los Angeles
| | - Sree Deepthi Muthukrishnan
- Intellectual and Developmental Disabilities Research Center, Semel Institute of Neuroscience, University of California Los Angeles
| | | | - Lea Guo
- Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles
| | - Jennifer An
- Department of Neurology, David Geffen School of Medicine, University of California Los Angeles
| | - Fanny Elahi
- Memory and Aging Center, University of California San Francisco
| | - Harley I. Kornblum
- Intellectual and Developmental Disabilities Research Center, Semel Institute of Neuroscience, University of California Los Angeles
| | - David S. Liebeskind
- Department of Neurology, David Geffen School of Medicine, University of California Los Angeles
| | - Tzung Hsiai
- Department of Medicine, David Geffen School of Medicine, University of California Los Angeles
- Veterans Healthcare Administration, Greater Los Angeles Healthcare System
| | - Jason D. Hinman
- Department of Neurology, David Geffen School of Medicine, University of California Los Angeles
- Veterans Healthcare Administration, Greater Los Angeles Healthcare System
| |
Collapse
|
15
|
Flow driven robotic navigation of microengineered endovascular probes. Nat Commun 2020; 11:6356. [PMID: 33353938 PMCID: PMC7755921 DOI: 10.1038/s41467-020-20195-z] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Accepted: 11/11/2020] [Indexed: 02/07/2023] Open
Abstract
Minimally invasive medical procedures, such as endovascular catheterization, have considerably reduced procedure time and associated complications. However, many regions inside the body, such as in the brain vasculature, still remain inaccessible due to the lack of appropriate guidance technologies. Here, experimentally and through numerical simulations, we show that tethered ultra-flexible endovascular microscopic probes can be transported through tortuous vascular networks with minimal external intervention by harnessing hydrokinetic energy. Dynamic steering at bifurcations is performed by deformation of the probe head using magnetic actuation. We developed an endovascular microrobotic toolkit with a cross-sectional area that is orders of magnitude smaller than the smallest catheter currently available. Our technology has the potential to improve state-of-the-art practices as it enhances the reachability, reduces the risk of iatrogenic damage, significantly increases the speed of robot-assisted interventions, and enables the deployment of multiple leads simultaneously through a standard needle injection and saline perfusion. The navigation of catheters through blood vessels requires flexible guiding wires that are pushable and tractable at the same time. Pancaldi et al. rely on hydrodynamic forces and magnetic torque in order to access even rather small capillaries with an ultraflexible magnetomechanical probe.
Collapse
|
16
|
Thrombus Imaging Using 3D Printed Middle Cerebral Artery Model and Preclinical Imaging Techniques: Application to Thrombus Targeting and Thrombolytic Studies. Pharmaceutics 2020; 12:pharmaceutics12121207. [PMID: 33322710 PMCID: PMC7763938 DOI: 10.3390/pharmaceutics12121207] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 12/08/2020] [Accepted: 12/09/2020] [Indexed: 01/01/2023] Open
Abstract
Diseases with the highest burden for society such as stroke, myocardial infarction, pulmonary embolism, and others are due to blood clots. Preclinical and clinical techniques to study blood clots are important tools for translational research of new diagnostic and therapeutic modalities that target blood clots. In this study, we employed a three-dimensional (3D) printed middle cerebral artery model to image clots under flow conditions using preclinical imaging techniques including fluorescent whole-body imaging, magnetic resonance imaging (MRI), and computed X-ray microtomography (microCT). Both liposome-based, fibrin-targeted, and non-targeted contrast agents were proven to provide a sufficient signal for clot imaging within the model under flow conditions. The application of the model for clot targeting studies and thrombolytic studies using preclinical imaging techniques is shown here. For the first time, a novel method of thrombus labeling utilizing barium sulphate (Micropaque®) is presented here as an example of successfully employed contrast agents for in vitro experiments evaluating the time-course of thrombolysis and thus the efficacy of a thrombolytic drug, recombinant tissue plasminogen activator (rtPA). Finally, the proof-of-concept of in vivo clot imaging in a middle cerebral artery occlusion (MCAO) rat model using barium sulphate-labelled clots is presented, confirming the great potential of such an approach to make experiments comparable between in vitro and in vivo models, finally leading to a reduction in animals needed.
Collapse
|
17
|
A Brush-Spin-Coating Method for Fabricating In Vitro Patient-Specific Vascular Models by Coupling 3D-Printing. Cardiovasc Eng Technol 2020; 12:200-214. [PMID: 33263929 DOI: 10.1007/s13239-020-00504-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Accepted: 11/18/2020] [Indexed: 12/31/2022]
Abstract
PURPOSE In vitro patient-specific flexible vascular models are helpful for understanding the haemodynamic changes before and after endovascular treatment and for effective training of neuroendovascular interventionalists. However, it is difficult to fabricate models of overall unified or controllable thickness using existing manufacturing methods. In this study, we developed an improved and easily implemented method by combining 3D printing and brush-spin-coating processes to produce a transparent silicone model of uniform or varied thickness. METHODS First, a water-soluble inner-skeleton model, based on clinical data, was printed on a 3D printer. The skeleton model was subsequently fixed in a single-axis-rotation machine to enable continuous coating of silicone, the thickness of which was manually controlled by adsorption and removal of excess silicone in a brush-spinning operation. After the silicone layer was solidified, the inner skeleton was further dissolved in a hot water bath, affording a transparent vascular model with real geometry. To verify the controllability of the coating thickness by using this method, a straight tube, an idealised aneurysm model, a patient-specific aortic arch model, and an abdominal aortic aneurysm model were manufactured. RESULTS The different thicknesses of the manufactured tubes could be well controlled, with the relative standard deviations being 5.6 and 8.1% for the straight and aneurysm tubes, respectively. Despite of the diameter changing from 33 to 20 mm in the patient-specific aorta, the thickness of the fabricated aortic model remains almost the same along the longitudinal direction with a lower standard deviation of 3.1%. In the more complex patient-specific abdominal aneurysm model, varied thicknesses were realized to mimic the measured data from the CT images, where the middle of the aneurysm was with 2 mm and abdominal aorta as well as the iliac arteries had the normal thickness of 2.3 mm. CONCLUSION Through the brush-spin-coating method, models of different sizes and complexity with prescribed thickness can be manufactured, which will be helpful for developing surgical treatment strategies or training neuroendovascular interventionalists.
Collapse
|
18
|
Joseph FJ, Weber S, Raabe A, Bervini D. Neurosurgical simulator for training aneurysm microsurgery-a user suitability study involving neurosurgeons and residents. Acta Neurochir (Wien) 2020; 162:2313-2321. [PMID: 32780255 PMCID: PMC7496061 DOI: 10.1007/s00701-020-04522-3] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 07/30/2020] [Indexed: 12/14/2022]
Abstract
BACKGROUND Due to its complexity and to existing treatment alternatives, exposure to intracranial aneurysm microsurgery at the time of neurosurgical residency is limited. The current state of the art includes training methods like assisting in surgeries, operating under supervision, and video training. These approaches are labor-intensive and difficult to fit into a timetable limited by the new work regulations. Existing virtual reality (VR)-based training modules lack patient-specific exercises and haptic properties and are thus inferior to hands-on training sessions and exposure to real surgical procedures. MATERIALS AND METHODS We developed a physical simulator able to reproduce the experience of clipping an intracranial aneurysm based on a patient-specific 3D-printed model of the skull, brain, and arteries. The simulator is made of materials that not only imitate tissue properties including arterial wall patency, thickness, and elasticity but also able to recreate a pulsatile blood flow. A sample group of 25 neurosurgeons and residents (n = 16: early residency with less than 4 years of neurosurgical exposure; n = 9: late residency and board-certified neurosurgeons, 4-15 years of neurosurgical exposure) took part to the study. Participants evaluated the simulator and were asked to answer questions about surgical simulation anatomy, realism, haptics, tactility, and general usage, scored on a 5-point Likert scale. In order to evaluate the feasibility of a future validation study on the role of the simulator in neurosurgical postgraduate training, an expert neurosurgeon assessed participants' clipping performance and a comparison between groups was done. RESULTS The proposed simulator is reliable and potentially useful for training neurosurgical residents and board-certified neurosurgeons. A large majority of participants (84%) found it a better alternative than conventional neurosurgical training methods. CONCLUSION The integration of a new surgical simulator including blood circulation and pulsatility should be considered as part of the future armamentarium of postgraduate education aimed to ensure high training standards for current and future generations of neurosurgeons involved in intracranial aneurysm surgery.
Collapse
Affiliation(s)
| | - Stefan Weber
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Andreas Raabe
- Department of Neurosurgery, Bern University Hospital and University of Bern, 3010, Bern, Switzerland
| | - David Bervini
- Department of Neurosurgery, Bern University Hospital and University of Bern, 3010, Bern, Switzerland.
| |
Collapse
|
19
|
In Vitro Modeling of Human Brain Arteriovenous Malformation for Endovascular Simulation and Flow Analysis. World Neurosurg 2020; 141:e873-e879. [DOI: 10.1016/j.wneu.2020.06.084] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 06/08/2020] [Accepted: 06/09/2020] [Indexed: 02/06/2023]
|
20
|
Phan TG, Ma H, Goyal M, Hilton J, Sinnott M, Srikanth V, Beare R. Computer Modeling of Clot Retrieval-Circle of Willis. Front Neurol 2020; 11:773. [PMID: 32849226 PMCID: PMC7427049 DOI: 10.3389/fneur.2020.00773] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 06/24/2020] [Indexed: 12/22/2022] Open
Abstract
Endovascular clot retrieval, often referred to as mechanical thrombectomy, has transformed the treatment of patients with ischemic stroke based on an underlying large cerebral vessel occlusion, ranging from the extracranial internal carotid artery (ICA) to the M1 (proximal) segment of the middle cerebral artery (MCA). The aim of this study was to evaluate the effect of a progressive occlusion of the extracranial portion of the ICA on the cerebral blood flow either with a conventional guiding catheter or a balloon-guiding catheter, which enables the operator to completely occlude the parent artery by inflating the balloon around the tip of this type of guiding catheter. We evaluated the impact of flow reduction in the ICA in the setting of ipsilateral MCA occlusion given the different configurations of the circle of Willis (CoW). The computer model of cerebral arteries was based on anatomical works by Rhoton (1) and van der Eecken (2). The interactive experimental results are available on the web at https://gntem3.shinyapps.io/ecrsim. In the setting of left MCA occlusion, compensation from the anterior and posterior communicating artery preserved the flow in the left anterior cerebral artery (ACA) but not the left MCA branches. Under selected CoW configurations, such as classic, missing Acom, or missing A1 segment of the ACA and concurrent right ICA occlusion, there was a progressive decrease of flow in the left ACA to a minimum of 78% when the simulated catheter fully occluded the left ICA. Flow collapsed (<10%) in the left ACA and MCA branches under CoW configurations, such as bilateral fetal PCA. In summary, compensatory flow collapsed under certain clot retrieval scenarios and unusual configurations of CoW.
Collapse
Affiliation(s)
- Thanh G Phan
- Stroke and Aging Research Group, Clinical Trials, Imaging and Informatics Division, School of Clinical Sciences at Monash Health, Monash University, Melbourne, VIC, Australia.,Department of Neurology, Monash Health, Melbourne, VIC, Australia
| | - Henry Ma
- Stroke and Aging Research Group, Clinical Trials, Imaging and Informatics Division, School of Clinical Sciences at Monash Health, Monash University, Melbourne, VIC, Australia.,Department of Neurology, Monash Health, Melbourne, VIC, Australia
| | - Mayank Goyal
- Departments of Clinical Neuroscience and Radiology, Cummings School of Medicine, Hotchkiss Brain Institute, University of Calgary, Calgary, AB, Canada
| | - James Hilton
- Data 61, CSIRO, Innovation Hub, Docklands, VIC, Australia
| | | | - Velandai Srikanth
- Department of Medicine, Peninsula Clinical School, Central Clinical School, Frankston Hospital, Monash University, Melbourne, VIC, Australia
| | - Richard Beare
- Departments of Clinical Neuroscience and Radiology, Cummings School of Medicine, Hotchkiss Brain Institute, University of Calgary, Calgary, AB, Canada
| |
Collapse
|
21
|
Campos JK, Lien BV, Wang AS, Lin LM. Advances in endovascular aneurysm management: coiling and adjunctive devices. Stroke Vasc Neurol 2020; 5:14-21. [PMID: 32411403 PMCID: PMC7213502 DOI: 10.1136/svn-2019-000303] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 02/15/2020] [Accepted: 02/27/2020] [Indexed: 01/30/2023] Open
Abstract
Endovascular coil embolisation continues to evolve and remains a valid modality in managing ruptured and unruptured cerebral aneurysms. Technological advances in coil properties, adjunctive devices and interventional techniques continue to improve long-term aneurysm occlusion rates. This review elaborates on the latest advances in next-generation endovascular coils and adjunctive coiling techniques for treating cerebral aneurysms.
Collapse
Affiliation(s)
- Jessica K Campos
- Department of Neurological Surgery, University of California Irvine Medical Center, Orange, California, USA
| | - Brian V Lien
- Department of Neurological Surgery, University of California Irvine Medical Center, Orange, California, USA
| | - Alice S Wang
- College of Osteopathic Medicine of the Pacific, Western University of Health Sciences, Pomona, California, USA
| | - Li-Mei Lin
- Carondelet Neurological Institute, St. Joseph's Hospital, Carondelet Health Network, Tucson, AZ, United States
| |
Collapse
|
22
|
Villadolid C, Puccini B, Dennis B, Gunnin T, Hedigan C, Cardinal KO. Custom tissue engineered aneurysm models with varying neck size and height for early stage in vitro testing of flow diverters. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2020; 31:34. [PMID: 32172490 PMCID: PMC7072062 DOI: 10.1007/s10856-020-06372-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Accepted: 02/28/2020] [Indexed: 05/03/2023]
Abstract
Endovascular techniques for treating cerebral aneurysms are rapidly advancing and require testing to optimize device configurations. The purpose of this work was to customize tissue-engineered aneurysm "blood vessel mimics" (aBVMs) for early stage in vitro assessment of vascular cell responses to flow diverters and other devices. Aneurysm scaffolds with varying neck size and height were created through solid modeling, mold fabrication, mandrel creation, and electrospinning. Scaffold dimensions and fiber morphology were characterized. aBVMs were created by depositing human smooth muscle and endothelial cells within scaffolds, and cultivating within perfusion bioreactors. These vessels were left untreated or used for flow diverter implantation. Cellular responses to flow diverters were evaluated at 3 days. Custom scaffolds were created with aneurysm neck diameters of 2.3, 3.5, and 5.5 mm and with aneurysm heights of 2, 5, and 8 mm. A set of scaffolds with varying neck size was used for aBVM creation, and dual-sodding of endothelial and smooth muscle cells resulted in consistent and confluent cellular linings. Flow diverters were successfully implanted in a subset of aBVMs, and initial cell coverage over devices was seen in the parent vessel at 3 days. Direct visualization of the device over the neck region was feasible, supporting the future use of these models for evaluating and comparing flow diverter healing. Tissue-engineered aneurysm models can be created with custom neck sizes and heights, and used to evaluate cellular responses to flow diverters and other endovascular devices.
Collapse
Affiliation(s)
- Camille Villadolid
- Biomedical Engineering Department, Cal Poly, 1 Grand Ave, San Luis Obispo, CA, 93407, USA
| | - Brandon Puccini
- Mechanical Engineering Department, Cal Poly, 1 Grand Ave, San Luis Obispo, CA, 93407, USA
| | - Benjamin Dennis
- Biomedical Engineering Department, Cal Poly, 1 Grand Ave, San Luis Obispo, CA, 93407, USA
| | - Tessa Gunnin
- Biomedical Engineering Department, Cal Poly, 1 Grand Ave, San Luis Obispo, CA, 93407, USA
| | - Conor Hedigan
- Biomedical Engineering Department, Cal Poly, 1 Grand Ave, San Luis Obispo, CA, 93407, USA
| | | |
Collapse
|
23
|
Kaneko N, Minhas A, Tateshima S, Colby GP, Szeder V, Hinman JD, Nour M, Jahan R, Duckwiler G. Pre-procedural simulation for precision stent-assisted coiling of cerebral aneurysm. Interv Neuroradiol 2019; 25:419-422. [PMID: 30922200 DOI: 10.1177/1591019919831923] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Artificial vascular models are emerging as a newly-inexpensive and accurate way to simulate a procedure before the treatment. Through utilization of precision three-dimensionally printed, silicone-reconstructed, patient-specific models of aneurysms, we can compare the performance of devices including stents, and accurately predict the behavior of the microcatheter and stent-assisted coiling in the aneurysm to not only reduce procedural time, but also make the procedure safer. Here we report two challenging cases of wide-necked aneurysms, which could be safely treated with stent-assisted coiling as simulated in the patient-specific aneurysm models.
Collapse
Affiliation(s)
- Naoki Kaneko
- 1 Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA
| | - Arjun Minhas
- 2 Georgetown University School of Medicine, Washington, DC, USA
| | - Satoshi Tateshima
- 1 Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA
| | - Geoffrey P Colby
- 1 Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA.,3 Department of Neurosurgery, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA
| | - Viktor Szeder
- 1 Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA
| | - Jason D Hinman
- 4 Department of Neurology, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA
| | - May Nour
- 1 Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA.,4 Department of Neurology, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA
| | - Reza Jahan
- 1 Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA
| | - Gary Duckwiler
- 1 Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA
| |
Collapse
|
24
|
Sandmann J, Müschenich FS, Riabikin A, Kramer M, Wiesmann M, Nikoubashman O. Can silicone models replace animal models in hands-on training for endovascular stroke therapy? Interv Neuroradiol 2019; 25:397-402. [PMID: 30895839 DOI: 10.1177/1591019919833843] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
PURPOSE Since thrombectomy has become a standard treatment technique for stroke, there is great demand for well-trained interventionalists. We offer practical courses on both silicone models and porcine models, and conducted a survey to evaluate whether ex vivo training models could replace in vivo models in the future. METHODS In total, 110 neurointerventionalists participating in 30 training courses were included in our survey using a semi-structured questionnaire. RESULTS The level of experience in thrombectomy maneuvers was almost balanced in our sample (52% experienced and 48% less-experienced participants). Silicone models were regarded as useful training tools regardless of the participants' experience (p = 1.000): 94% of less-experienced and 92% of experienced participants considered a silicone model to be a useful introduction for training with animal models. Of the participants, 95% indicated that training on animal models was helpful and necessary, even if they already had experience in performing interventions in humans (p = 1.000). After joining this course, 97% of all participants felt well prepared to perform thrombectomies in humans. CONCLUSION Even experienced participants benefit from silicone models. Silicone models are a good preparation for animal models but cannot replace them. Categorizing participants depending on their experience and their individual needs before practical training may allow for more efficient endovascular training.
Collapse
Affiliation(s)
- Johanna Sandmann
- 1 Department of Diagnostic and Interventional Neuroradiology, RWTH Aachen University, Aachen, Germany
| | | | - Alexander Riabikin
- 1 Department of Diagnostic and Interventional Neuroradiology, RWTH Aachen University, Aachen, Germany
| | - Martin Kramer
- 2 Department of Veterinary Clinical Sciences, Justus-Liebig-University, Gießen, Germany
| | - Martin Wiesmann
- 1 Department of Diagnostic and Interventional Neuroradiology, RWTH Aachen University, Aachen, Germany
| | - Omid Nikoubashman
- 1 Department of Diagnostic and Interventional Neuroradiology, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
25
|
Nakayama M, Yamamoto S, Kaneko N, Mato N, Suzuki T, Hagiwara K. Use of low-cost three-dimensional printer to simulate grasping of bronchial foreign body. Respirol Case Rep 2018; 6:e00351. [PMID: 30009031 PMCID: PMC6041124 DOI: 10.1002/rcr2.351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Accepted: 06/12/2018] [Indexed: 12/04/2022] Open
Abstract
An 89-year-old man was hospitalized with severe pneumonia. Chest computed tomography showed a foreign body in the left main bronchus. We moulded a three-dimensional (3D) model of the foreign body with a low-cost 3D printer and found it had the shape of a tooth. We simulated grasping the model with several forceps and succeeded in grasping it with a retrieval net and shark-tooth forceps. Bronchoscopy was performed after his respiratory condition improved. We found a dental foreign body that had accidentally moved and become stuck in the right upper bronchus. We scraped it out with a retrieval net and grasped the recess site of the foreign body with a shark-tooth forceps as performed in the simulation. Removal was successful, and the total bronchoscopy time was 9 min. The bronchial foreign body was safely grasped and removed in a short time after simulation with several forceps using a low-cost 3D printer.
Collapse
Affiliation(s)
- Masayuki Nakayama
- Division of Pulmonary Medicine, Department of MedicineJichi Medical UniversityShimotsukeTochigiJapan
| | - Shinichi Yamamoto
- Department of General Thoracic SurgeryJichi Medical UniversityShimotsukeTochigiJapan
| | - Naoki Kaneko
- Division of Interventional NeuroradiologyRonald Reagan UCLA Medical CenterLos AngelesUSA
| | - Naoko Mato
- Division of Pulmonary Medicine, Department of MedicineJichi Medical UniversityShimotsukeTochigiJapan
| | - Takuji Suzuki
- Division of Pulmonary Medicine, Department of MedicineJichi Medical UniversityShimotsukeTochigiJapan
| | - Koichi Hagiwara
- Division of Pulmonary Medicine, Department of MedicineJichi Medical UniversityShimotsukeTochigiJapan
| |
Collapse
|
26
|
Hayakawa T, Maruyama H, Watanabe T, Arai F. Three-Dimensional Blood Vessel Model with Temperature-Indicating Function for Evaluation of Thermal Damage during Surgery. SENSORS 2018; 18:s18020345. [PMID: 29370139 PMCID: PMC5855279 DOI: 10.3390/s18020345] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Revised: 01/20/2018] [Accepted: 01/23/2018] [Indexed: 01/28/2023]
Abstract
Surgical simulators have recently attracted attention because they enable the evaluation of the surgical skills of medical doctors and the performance of medical devices. However, thermal damage to the human body during surgery is difficult to evaluate using conventional surgical simulators. In this study, we propose a functional surgical model with a temperature-indicating function for the evaluation of thermal damage during surgery. The simulator is made of a composite material of polydimethylsiloxane and a thermochromic dye, which produces an irreversible color change as the temperature increases. Using this material, we fabricated a three-dimensional blood vessel model using the lost-wax process. We succeeded in fabricating a renal vessel model for simulation of catheter ablation. Increases in the temperature of the materials can be measured by image analysis of their color change. The maximum measurement error of the temperature was approximately -1.6 °C/+2.4 °C within the range of 60 °C to 100 °C.
Collapse
Affiliation(s)
- Takeshi Hayakawa
- Room 310, Aerospace Mechanical Engineering Research Building 3F, Department of Micro-Nano Mechanical Science & Engineering, Nagoya University, Furo-cho, Chikusa-ku, Aichi-Pref., Nagoya-shi 464-8603, Japan.
| | - Hisataka Maruyama
- Room 310, Aerospace Mechanical Engineering Research Building 3F, Department of Micro-Nano Mechanical Science & Engineering, Nagoya University, Furo-cho, Chikusa-ku, Aichi-Pref., Nagoya-shi 464-8603, Japan.
| | - Takafumi Watanabe
- Room 310, Aerospace Mechanical Engineering Research Building 3F, Department of Micro-Nano Mechanical Science & Engineering, Nagoya University, Furo-cho, Chikusa-ku, Aichi-Pref., Nagoya-shi 464-8603, Japan.
| | - Fumihito Arai
- Room 310, Aerospace Mechanical Engineering Research Building 3F, Department of Micro-Nano Mechanical Science & Engineering, Nagoya University, Furo-cho, Chikusa-ku, Aichi-Pref., Nagoya-shi 464-8603, Japan.
| |
Collapse
|
27
|
Kaneko N, Mashiko T, Namba K, Tateshima S, Watanabe E, Kawai K. A patient-specific intracranial aneurysm model with endothelial lining: a novel in vitro approach to bridge the gap between biology and flow dynamics. J Neurointerv Surg 2017; 10:306-309. [PMID: 28652298 DOI: 10.1136/neurintsurg-2017-013087] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2017] [Accepted: 05/02/2017] [Indexed: 11/04/2022]
Abstract
OBJECTIVES To develop an in vitro model for studying the biological effect of complex-flow stress on endothelial cells in three-dimensional (3D) patient-specific vascular geometry. MATERIALS AND METHODS A vessel replica was fabricated with polydimethylsiloxanes using 3D printing technology from vascular image data acquired by rotational angiography. The vascular model was coated with fibronectin and immersed in a tube filled with a cell suspension of endothelium, and then cultured while being slowly rotated in three dimensions. Culture medium with viscosity was perfused in the circulation with the endothelialized vascular model. A computational fluid dynamics (CFD) study was conducted using perfusion conditions used in the flow experiment. The morphology of endothelial cells was observed under a confocal microscope. RESULTS The CFD study showed low wall shear stress and circulating flow in the apex of the basilar tip aneurysm, with linear flow in the parent artery. Confocal imaging demonstrated that the inner surface of the vascular model was evenly covered with monolayer endothelial cells. After 24 h of flow circulation, endothelial cells in the parent artery exhibited a spindle shape and aligned with the flow direction. In contrast, endothelial cells in the aneurysmal apex were irregular in shape and size. CONCLUSIONS A geometrically realistic intracranial aneurysm model with live endothelial lining was successfully developed. This in vitro model enables a new research approach combining study of the biological impact of complex flow on endothelial cells with CFD analysis and patient information, including the presence of aneurysmal growth or rupture.
Collapse
Affiliation(s)
- Naoki Kaneko
- Department of Neurosurgery, Jichi Medical University, Shimotsuke, Japan.,Division of Interventional Neuroradiology, University of California, Los Angeles, Los Angeles, California, USA
| | - Toshihiro Mashiko
- Department of Neurosurgery, Jichi Medical University, Shimotsuke, Japan
| | - Katsunari Namba
- Department of Endovascular Surgery, Jichi Medical University, Shimotsuke, Japan
| | - Satoshi Tateshima
- Division of Interventional Neuroradiology, University of California, Los Angeles, Los Angeles, California, USA
| | - Eiju Watanabe
- Department of Neurosurgery, Jichi Medical University, Shimotsuke, Japan
| | - Kensuke Kawai
- Department of Neurosurgery, Jichi Medical University, Shimotsuke, Japan
| |
Collapse
|
28
|
Vennin C, Chin VT, Warren SC, Lucas MC, Herrmann D, Magenau A, Melenec P, Walters SN, Del Monte-Nieto G, Conway JRW, Nobis M, Allam AH, McCloy RA, Currey N, Pinese M, Boulghourjian A, Zaratzian A, Adam AAS, Heu C, Nagrial AM, Chou A, Steinmann A, Drury A, Froio D, Giry-Laterriere M, Harris NLE, Phan T, Jain R, Weninger W, McGhee EJ, Whan R, Johns AL, Samra JS, Chantrill L, Gill AJ, Kohonen-Corish M, Harvey RP, Biankin AV, Evans TRJ, Anderson KI, Grey ST, Ormandy CJ, Gallego-Ortega D, Wang Y, Samuel MS, Sansom OJ, Burgess A, Cox TR, Morton JP, Pajic M, Timpson P. Transient tissue priming via ROCK inhibition uncouples pancreatic cancer progression, sensitivity to chemotherapy, and metastasis. Sci Transl Med 2017; 9:eaai8504. [PMID: 28381539 PMCID: PMC5777504 DOI: 10.1126/scitranslmed.aai8504] [Citation(s) in RCA: 187] [Impact Index Per Article: 26.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2016] [Revised: 12/21/2016] [Accepted: 03/04/2017] [Indexed: 12/18/2022]
Abstract
The emerging standard of care for patients with inoperable pancreatic cancer is a combination of cytotoxic drugs gemcitabine and Abraxane, but patient response remains moderate. Pancreatic cancer development and metastasis occur in complex settings, with reciprocal feedback from microenvironmental cues influencing both disease progression and drug response. Little is known about how sequential dual targeting of tumor tissue tension and vasculature before chemotherapy can affect tumor response. We used intravital imaging to assess how transient manipulation of the tumor tissue, or "priming," using the pharmaceutical Rho kinase inhibitor Fasudil affects response to chemotherapy. Intravital Förster resonance energy transfer imaging of a cyclin-dependent kinase 1 biosensor to monitor the efficacy of cytotoxic drugs revealed that priming improves pancreatic cancer response to gemcitabine/Abraxane at both primary and secondary sites. Transient priming also sensitized cells to shear stress and impaired colonization efficiency and fibrotic niche remodeling within the liver, three important features of cancer spread. Last, we demonstrate a graded response to priming in stratified patient-derived tumors, indicating that fine-tuned tissue manipulation before chemotherapy may offer opportunities in both primary and metastatic targeting of pancreatic cancer.
Collapse
Affiliation(s)
- Claire Vennin
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Venessa T Chin
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Sean C Warren
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Morghan C Lucas
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - David Herrmann
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Astrid Magenau
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Pauline Melenec
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Stacey N Walters
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Gonzalo Del Monte-Nieto
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
- Developmental and Stem Cell Biology Division, Victor Chang Cardiac Research Institute, Sydney, New South Wales 2010, Australia
| | - James R W Conway
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Max Nobis
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Amr H Allam
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Rachael A McCloy
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Nicola Currey
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Mark Pinese
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Alice Boulghourjian
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
| | - Anaiis Zaratzian
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
| | - Arne A S Adam
- Developmental and Stem Cell Biology Division, Victor Chang Cardiac Research Institute, Sydney, New South Wales 2010, Australia
| | - Celine Heu
- Biomedical Imaging Facility, Mark Wainwright Analytical Centre, Lowy Cancer Research Centre, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Adnan M Nagrial
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
| | - Angela Chou
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
- Department of Pathology, St. Vincent's Hospital, Sydney, New South Wales 2010, Australia
| | - Angela Steinmann
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
| | - Alison Drury
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
| | - Danielle Froio
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
| | - Marc Giry-Laterriere
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Nathanial L E Harris
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- Illawarra Health and Medical Research Institute, University of Wollongong, Wollongong, New South Wales 2522, Australia
| | - Tri Phan
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Rohit Jain
- Immune Imaging Program, Centenary Institute, University of Sydney, Sydney, New South Wales 2006, Australia
- University of Sydney Medical School, Sydney, New South Wales 2006, Australia
| | - Wolfgang Weninger
- Immune Imaging Program, Centenary Institute, University of Sydney, Sydney, New South Wales 2006, Australia
- University of Sydney Medical School, Sydney, New South Wales 2006, Australia
- Department of Dermatology, Royal Prince Alfred Hospital, Camperdown, New South Wales 2050, Australia
| | - Ewan J McGhee
- Cancer Research UK Beatson Institute, Glasgow, Scotland G61 BD, U.K
| | - Renee Whan
- Developmental and Stem Cell Biology Division, Victor Chang Cardiac Research Institute, Sydney, New South Wales 2010, Australia
| | - Amber L Johns
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- Cancer Diagnosis and Pathology Research Group, Kolling Institute of Medical Research and Royal North Shore Hospital, Sydney, New South Wales 2065, Australia
- University of Sydney, Sydney, New South Wales 2006, Australia
- Australian Pancreatic Cancer Genome Initiative
| | - Jaswinder S Samra
- Cancer Research UK Beatson Institute, Glasgow, Scotland G61 BD, U.K
- Australian Pancreatic Cancer Genome Initiative
- Department of Surgery, Royal North Shore Hospital, Sydney, New South Wales 2065, Australia
| | - Lorraine Chantrill
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- Australian Pancreatic Cancer Genome Initiative
- Department of Surgery, Royal North Shore Hospital, Sydney, New South Wales 2065, Australia
| | - Anthony J Gill
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- Cancer Diagnosis and Pathology Research Group, Kolling Institute of Medical Research and Royal North Shore Hospital, Sydney, New South Wales 2065, Australia
- University of Sydney, Sydney, New South Wales 2006, Australia
- Australian Pancreatic Cancer Genome Initiative
- Macarthur Cancer Therapy Centre, Campbelltown Hospital, Sydney, New South Wales 2560, Australia
| | - Maija Kohonen-Corish
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
- School of Medicine, Western Sydney University, Penrith, Sydney, New South Wales 2751, Australia
| | - Richard P Harvey
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
- Developmental and Stem Cell Biology Division, Victor Chang Cardiac Research Institute, Sydney, New South Wales 2010, Australia
- School of Biotechnology and Biomolecular Science, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Andrew V Biankin
- Australian Pancreatic Cancer Genome Initiative
- Wolfson Wohl Cancer Research Centre, Institute of Cancer Sciences, University of Glasgow, Scotland G61 BD, U.K
- West of Scotland Pancreatic Unit, Glasgow Royal Infirmary, Scotland G61 BD, U.K
| | - T R Jeffry Evans
- Cancer Research UK Beatson Institute, Glasgow, Scotland G61 BD, U.K
| | - Kurt I Anderson
- Cancer Research UK Beatson Institute, Glasgow, Scotland G61 BD, U.K
| | - Shane T Grey
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Christopher J Ormandy
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - David Gallego-Ortega
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Yingxiao Wang
- Department of Bioengineering, Institute of Engineering in Medicine, University of California, San Diego, San Diego, CA 92121, USA
| | - Michael S Samuel
- Centre for Cancer Biology, SA Pathology and University of South Australia School of Medicine, University of Adelaide, Adelaide, South Australia 5000, Australia
| | - Owen J Sansom
- Cancer Research UK Beatson Institute, Glasgow, Scotland G61 BD, U.K
| | - Andrew Burgess
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Thomas R Cox
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | | | - Marina Pajic
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia.
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| | - Paul Timpson
- The Kinghorn Cancer Centre, Garvan Institute of Medical Research, Sydney, New South Wales 2010, Australia.
- St. Vincent's Clinical School, Faculty of Medicine, University of New South Wales, Sydney, New South Wales 2010, Australia
| |
Collapse
|