1
|
Kim PG, Choi YH, Lee A, Shin J, Song E, Sochichiu S, Koo Y, Hong Y, Kwon JH. Determination of personal exposure to volatile organic compounds and their health risks after the use of mosquito repellents in residential environments using passive sampling. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 949:175158. [PMID: 39094641 DOI: 10.1016/j.scitotenv.2024.175158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Revised: 07/28/2024] [Accepted: 07/28/2024] [Indexed: 08/04/2024]
Abstract
The ubiquitous use of mosquito repellents in homes across Asia, Africa, and South America is related with human exposure to indoor volatile organic compounds (VOCs). There are three primary types of mosquito repellents: those in the form of coils, mats, and liquids. The repellent mechanisms of these products are distinct, resulting in the generation of varying types of VOCs during the repellent process. In this study, the emission characteristics of commercial coil-, mat-, and liquid-type mosquito repellents were observed in a laboratory chamber using real-time measurement. A previously developed personal passive sampler, ePTFE PS, was used to quantify personal exposure to indoor VOCs while 86 volunteers habitually used those three representative types for 3 h in their residence. Notable increase of indoor benzene was observed for coil- and mat-type mosquito repellents, while α-pinene concentration increased significantly following the use of liquid-type mosquito repellent. The average incremental cancer risks for benzene were 10-6 to 10-4 for adults following the use of coil- and mat-type mosquito repellents. The average non-cancer risks for all chemicals were <1 after the use of three types of mosquito repellents. Considering the potential human health risks associated with byproducts (e.g., particulate matter or carbon monoxide from incomplete combustion) emitted after mosquito coil use, further research on this topic is warranted.
Collapse
Affiliation(s)
- Pil-Gon Kim
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea; Department of Environmental Education, Mokpo National University, Muan, Jeonnam 58554, Republic of Korea
| | - Yun-Hee Choi
- Department of Ophthalmology, Korea University College of Medicine, Seoul 02841, Republic of Korea; School of Health and Environmental Science, Korea University, Seoul 02841, Republic of Korea
| | - Arum Lee
- Department of Consumer Science, Chungbuk National University, Cheongju 28644, Republic of Korea
| | - Jaeho Shin
- Department of Consumer Science, Chungbuk National University, Cheongju 28644, Republic of Korea
| | - Eugene Song
- Department of Consumer Science, Chungbuk National University, Cheongju 28644, Republic of Korea
| | - Stefana Sochichiu
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Yerim Koo
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Yongseok Hong
- Department of Environmental Engineering, College of Science and Technology, Korea University Sejong Campus, Sejong City 30019, Republic of Korea
| | - Jung-Hwan Kwon
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea.
| |
Collapse
|
2
|
Lai Y, Koelmel JP, Walker DI, Price EJ, Papazian S, Manz KE, Castilla-Fernández D, Bowden JA, Nikiforov V, David A, Bessonneau V, Amer B, Seethapathy S, Hu X, Lin EZ, Jbebli A, McNeil BR, Barupal D, Cerasa M, Xie H, Kalia V, Nandakumar R, Singh R, Tian Z, Gao P, Zhao Y, Froment J, Rostkowski P, Dubey S, Coufalíková K, Seličová H, Hecht H, Liu S, Udhani HH, Restituito S, Tchou-Wong KM, Lu K, Martin JW, Warth B, Godri Pollitt KJ, Klánová J, Fiehn O, Metz TO, Pennell KD, Jones DP, Miller GW. High-Resolution Mass Spectrometry for Human Exposomics: Expanding Chemical Space Coverage. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:12784-12822. [PMID: 38984754 PMCID: PMC11271014 DOI: 10.1021/acs.est.4c01156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 06/11/2024] [Accepted: 06/12/2024] [Indexed: 07/11/2024]
Abstract
In the modern "omics" era, measurement of the human exposome is a critical missing link between genetic drivers and disease outcomes. High-resolution mass spectrometry (HRMS), routinely used in proteomics and metabolomics, has emerged as a leading technology to broadly profile chemical exposure agents and related biomolecules for accurate mass measurement, high sensitivity, rapid data acquisition, and increased resolution of chemical space. Non-targeted approaches are increasingly accessible, supporting a shift from conventional hypothesis-driven, quantitation-centric targeted analyses toward data-driven, hypothesis-generating chemical exposome-wide profiling. However, HRMS-based exposomics encounters unique challenges. New analytical and computational infrastructures are needed to expand the analysis coverage through streamlined, scalable, and harmonized workflows and data pipelines that permit longitudinal chemical exposome tracking, retrospective validation, and multi-omics integration for meaningful health-oriented inferences. In this article, we survey the literature on state-of-the-art HRMS-based technologies, review current analytical workflows and informatic pipelines, and provide an up-to-date reference on exposomic approaches for chemists, toxicologists, epidemiologists, care providers, and stakeholders in health sciences and medicine. We propose efforts to benchmark fit-for-purpose platforms for expanding coverage of chemical space, including gas/liquid chromatography-HRMS (GC-HRMS and LC-HRMS), and discuss opportunities, challenges, and strategies to advance the burgeoning field of the exposome.
Collapse
Affiliation(s)
- Yunjia Lai
- Department
of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York 10032, United States
| | - Jeremy P. Koelmel
- Department
of Environmental Health Sciences, Yale School
of Public Health, New Haven, Connecticut 06520, United States
| | - Douglas I. Walker
- Gangarosa
Department of Environmental Health, Rollins School of Public Health, Emory University, Atlanta, Georgia 30322, United States
| | - Elliott J. Price
- RECETOX,
Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic
| | - Stefano Papazian
- Department
of Environmental Science, Science for Life Laboratory, Stockholm University, SE-106 91 Stockholm, Sweden
- National
Facility for Exposomics, Metabolomics Platform, Science for Life Laboratory, Stockholm University, Solna 171 65, Sweden
| | - Katherine E. Manz
- Department
of Environmental Health Sciences, School of Public Health, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Delia Castilla-Fernández
- Department
of Food Chemistry and Toxicology, Faculty of Chemistry, University of Vienna, 1010 Vienna, Austria
| | - John A. Bowden
- Center for
Environmental and Human Toxicology, Department of Physiological Sciences,
College of Veterinary Medicine, University
of Florida, Gainesville, Florida 32611, United States
| | | | - Arthur David
- Univ Rennes,
Inserm, EHESP, Irset (Institut de recherche en santé, environnement
et travail) − UMR_S, 1085 Rennes, France
| | - Vincent Bessonneau
- Univ Rennes,
Inserm, EHESP, Irset (Institut de recherche en santé, environnement
et travail) − UMR_S, 1085 Rennes, France
| | - Bashar Amer
- Thermo
Fisher Scientific, San Jose, California 95134, United States
| | | | - Xin Hu
- Gangarosa
Department of Environmental Health, Rollins School of Public Health, Emory University, Atlanta, Georgia 30322, United States
| | - Elizabeth Z. Lin
- Department
of Environmental Health Sciences, Yale School
of Public Health, New Haven, Connecticut 06520, United States
| | - Akrem Jbebli
- RECETOX,
Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic
| | - Brooklynn R. McNeil
- Biomarkers
Core Laboratory, Irving Institute for Clinical and Translational Research, Columbia University Irving Medical Center, New York, New York 10032, United States
| | - Dinesh Barupal
- Department
of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, New York 10029, United States
| | - Marina Cerasa
- Institute
of Atmospheric Pollution Research, Italian National Research Council, 00015 Monterotondo, Rome, Italy
| | - Hongyu Xie
- Department
of Environmental Science, Science for Life Laboratory, Stockholm University, SE-106 91 Stockholm, Sweden
| | - Vrinda Kalia
- Department
of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York 10032, United States
| | - Renu Nandakumar
- Biomarkers
Core Laboratory, Irving Institute for Clinical and Translational Research, Columbia University Irving Medical Center, New York, New York 10032, United States
| | - Randolph Singh
- Department
of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York 10032, United States
| | - Zhenyu Tian
- Department
of Chemistry and Chemical Biology, Northeastern
University, Boston, Massachusetts 02115, United States
| | - Peng Gao
- Department
of Environmental and Occupational Health, and Department of Civil
and Environmental Engineering, University
of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
- UPMC Hillman
Cancer Center, Pittsburgh, Pennsylvania 15232, United States
| | - Yujia Zhao
- Institute
for Risk Assessment Sciences, Utrecht University, Utrecht 3584CM, The Netherlands
| | | | | | - Saurabh Dubey
- Biomarkers
Core Laboratory, Irving Institute for Clinical and Translational Research, Columbia University Irving Medical Center, New York, New York 10032, United States
| | - Kateřina Coufalíková
- RECETOX,
Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic
| | - Hana Seličová
- RECETOX,
Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic
| | - Helge Hecht
- RECETOX,
Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic
| | - Sheng Liu
- Department
of Environmental Health Sciences, Yale School
of Public Health, New Haven, Connecticut 06520, United States
| | - Hanisha H. Udhani
- Biomarkers
Core Laboratory, Irving Institute for Clinical and Translational Research, Columbia University Irving Medical Center, New York, New York 10032, United States
| | - Sophie Restituito
- Department
of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York 10032, United States
| | - Kam-Meng Tchou-Wong
- Department
of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York 10032, United States
| | - Kun Lu
- Department
of Environmental Sciences and Engineering, Gillings School of Global
Public Health, The University of North Carolina
at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| | - Jonathan W. Martin
- Department
of Environmental Science, Science for Life Laboratory, Stockholm University, SE-106 91 Stockholm, Sweden
- National
Facility for Exposomics, Metabolomics Platform, Science for Life Laboratory, Stockholm University, Solna 171 65, Sweden
| | - Benedikt Warth
- Department
of Food Chemistry and Toxicology, Faculty of Chemistry, University of Vienna, 1010 Vienna, Austria
| | - Krystal J. Godri Pollitt
- Department
of Environmental Health Sciences, Yale School
of Public Health, New Haven, Connecticut 06520, United States
| | - Jana Klánová
- RECETOX,
Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic
| | - Oliver Fiehn
- West Coast
Metabolomics Center, University of California−Davis, Davis, California 95616, United States
| | - Thomas O. Metz
- Biological
Sciences Division, Pacific Northwest National
Laboratory, Richland, Washington 99354, United States
| | - Kurt D. Pennell
- School
of Engineering, Brown University, Providence, Rhode Island 02912, United States
| | - Dean P. Jones
- Department
of Medicine, School of Medicine, Emory University, Atlanta, Georgia 30322, United States
| | - Gary W. Miller
- Department
of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York 10032, United States
| |
Collapse
|
3
|
Kim PG, Lee A, Shin J, Song E, Koo Y, Sochichiu S, Mohamed DFMS, Choi S, Hong Y, Kwon JH. Increase of the indoor concentration of volatile organic compounds after the use of incense and scented candle in studio apartments determined using passive sampling. CHEMOSPHERE 2024; 359:142344. [PMID: 38754484 DOI: 10.1016/j.chemosphere.2024.142344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 05/10/2024] [Accepted: 05/14/2024] [Indexed: 05/18/2024]
Abstract
Burning incenses and scented candles may provide harmful chemicals. Although many studies have evaluated volatile organic chemicals emitted by their use and related health risks, extension of our understanding for guiding appropriate use under various use conditions is necessary. In this study, emission characteristics of commercial incenses and scented candles were evaluated in a laboratory chamber using real-time measurement and the time-weighted average exposure concentrations of monoaromatic compounds and monoterpenes were assessed using passive samplers while volunteers living in a studio apartment use them. After burning incense, the average levels of benzene increased from 1.4 to 100 μg m-3. The presence of a wood core in commercial incense products was the main cause of high benzene emission by burning them although the increase in benzene was also influenced by factors such as the brand of the products, the number of incense sticks burned, the duration of each burning session, and ventilation period. Electrical warming of scented candles increased the levels of monoterpenes by factors of 16-30 on average. Considering the emission characteristics found in this study, exposure to benzene and monoterpenes could be mitigated by cautious use of those products in residential areas.
Collapse
Affiliation(s)
- Pil-Gon Kim
- Department of Environmental Education, Mokpo National University, Muan, Jeonnam, 58554, Republic of Korea; Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Arum Lee
- Department of Consumer Science, Chungbuk National University, Cheongju, 28644, Republic of Korea
| | - Jaeho Shin
- Department of Consumer Science, Chungbuk National University, Cheongju, 28644, Republic of Korea
| | - Eugene Song
- Department of Consumer Science, Chungbuk National University, Cheongju, 28644, Republic of Korea
| | - Yerim Koo
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Stefana Sochichiu
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Dana Fahad M S Mohamed
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Soobin Choi
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Yongseok Hong
- Department of Environmental Engineering, College of Science and Technology, Korea University Sejong Campus, Sejong, 30019, Republic of Korea
| | - Jung-Hwan Kwon
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
| |
Collapse
|
4
|
Grieco M, Giorgi A, Giacovazzo G, Maggiore A, Ficchì S, d'Erme M, Mosca L, Mignogna G, Maras B, Coccurello R. β-Hexachlorocyclohexane triggers neuroinflammatory activity, epigenetic histone post-translational modifications and cognitive dysfunction. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2024; 279:116487. [PMID: 38810285 DOI: 10.1016/j.ecoenv.2024.116487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 05/06/2024] [Accepted: 05/18/2024] [Indexed: 05/31/2024]
Abstract
Persistent organic pollutants (POPs), which encompass pesticides and industrial chemicals widely utilized across the globe, pose a covert threat to human health. β-hexachlorocyclohexane (β-HCH) is an organochlorine pesticide with striking stability, still illegally dumped in many countries, and recognized as responsible for several pathogenetic mechanisms. This study represents a pioneering exploration into the neurotoxic effects induced by the exposure to β-HCH specifically targeting neuronal cells (N2a), microglia (BV-2), and C57BL/6 mice. As shown by western blot and qPCR analyses, the administration of β-HCH triggered a modulation of NF-κB, a key factor influencing both inflammation and pro-inflammatory cytokines expression. We demonstrated by proteomic and western blot techniques epigenetic modifications in H3 histone induced by β-HCH. Histone acetylation of H3K9 and H3K27 increased in N2a, and in the prefrontal cortex of C57BL/6 mice administered with β-HCH, whereas it decreased in BV-2 cells and in the hippocampus. We also observed a severe detrimental effect on recognition memory and spatial navigation by the Novel Object Recognition Test (NORT) and the Object Place Recognition Task (OPRT) behavioural tests. Cognitive impairment was linked to decreased expression of the genes BDNF and SNAP-25, which are mediators involved in synaptic function and activity. The obtained results expand our understanding of the harmful impact produced by β-HCH exposure by highlighting its implication in the pathogenesis of neurological diseases. These findings will support intervention programs to limit the risk induced by exposure to POPs. Regulatory agencies should block further illicit use, causing environmental hazards and endangering human and animal health.
Collapse
Affiliation(s)
- Maddalena Grieco
- Department of Biochemical Sciences, Sapienza University, Rome, Italy
| | - Alessandra Giorgi
- Department of Biochemical Sciences, Sapienza University, Rome, Italy
| | - Giacomo Giacovazzo
- European Center for Brain Research, Santa Lucia Foundation IRCCS, Rome, Italy
| | - Anna Maggiore
- Department of Biochemical Sciences, Sapienza University, Rome, Italy; Department of Brain Sciences, Imperial College, London, UK
| | - Serena Ficchì
- Department of Biochemical Sciences, Sapienza University, Rome, Italy
| | - Maria d'Erme
- Department of Biochemical Sciences, Sapienza University, Rome, Italy
| | - Luciana Mosca
- Department of Biochemical Sciences, Sapienza University, Rome, Italy
| | | | - Bruno Maras
- Department of Biochemical Sciences, Sapienza University, Rome, Italy.
| | - Roberto Coccurello
- European Center for Brain Research, Santa Lucia Foundation IRCCS, Rome, Italy; Institute for Complex Systems, National Research Council (CNR), Roma, Italy
| |
Collapse
|
5
|
Wang Z, Yu T, Ye J, Tian L, Lin B, Leng W, Liu C. A novel low sampling rate and cost-efficient active sampler for medium/long-term monitoring of gaseous pollutants. JOURNAL OF HAZARDOUS MATERIALS 2024; 461:132583. [PMID: 37741205 DOI: 10.1016/j.jhazmat.2023.132583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 09/14/2023] [Accepted: 09/17/2023] [Indexed: 09/25/2023]
Abstract
Active sampling is a dependable approach for gaseous pollutants monitoring, offering high accuracy and precision that is unaffected by environmental factors such as wind and temperature in comparison to passive sampling. To measure long-term average concentrations while minimizing the use of materials, a reduced sampling rate is necessary. Thus, this study aims to develop a novel low sampling rate (down to 1 mL/min) and cost-efficient active sampler (LASP) for medium/long-term monitoring of gaseous pollutants. The LASP mainly consisted of a syringe pump, a Y-shaped fitting with two one-way valves, and a control unit for intermittent operation. Results showed that LASP can obtain a sampling rate of less than 1 mL/min and sampling rate exhibited a high level of stability. Daily average concentrations measurements for nitrogen dioxide and formaldehyde by LASP had normalized mean biases of 2.8% and 5.2%, respectively. These numbers were - 5.8% and 6.1% for weekly-average samplings. This study demonstrated applications of LASP in real outdoor (daily-average) and indoor (weekly-average) air quality measurements. It worked well with low noise levels, and without interfering with occupants' daily activities. LASP can assist in improving our ability to monitor air quality and pollutants emissions, thereby supporting health research and policy development. ENVIRONMENTAL IMPLICATION: Gaseous air pollution is an important hazardous factor threatening human health. Medium/long-term air quality monitoring is essential for outdoor and indoor air quality assessment and control. However, air sampler for medium/long-term sampling is lacking. This study developed a novel low sampling rate and cost-efficient active sampler and applied it to medium/long-term air sampling. The sampler can work at a sampling rate of less than 1 mL/min. This technology provides a feasible strategy for medium/long-term monitoring of gaseous air pollutants in both environments and emission hotspots.
Collapse
Affiliation(s)
- Zhiyuan Wang
- School of Energy and Environment, Southeast University, Nanjing 210096, China
| | - Tao Yu
- Wuhan Second Ship Design and Research Institute, Wuhan 430205, China
| | - Jin Ye
- School of Energy and Power, Jiangsu University of Science and Technology, Zhenjiang, Jiangsu 212100, China
| | - Lei Tian
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Bencheng Lin
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Wenjun Leng
- Wuhan Second Ship Design and Research Institute, Wuhan 430205, China
| | - Cong Liu
- School of Energy and Environment, Southeast University, Nanjing 210096, China.
| |
Collapse
|
6
|
Udomkun P, Boonupara T, Sumitsawan S, Khan E, Pongpichan S, Kajitvichyanukul P. Airborne Pesticides-Deep Diving into Sampling and Analysis. TOXICS 2023; 11:883. [PMID: 37999535 PMCID: PMC10674914 DOI: 10.3390/toxics11110883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 10/23/2023] [Accepted: 10/25/2023] [Indexed: 11/25/2023]
Abstract
The escalating utilization of pesticides has led to pronounced environmental contamination, posing a significant threat to agroecosystems. The extensive and persistent global application of these chemicals has been linked to a spectrum of acute and chronic human health concerns. This review paper focuses on the concentrations of airborne pesticides in both indoor and outdoor environments. The collection of diverse pesticide compounds from the atmosphere is examined, with a particular emphasis on active and passive air sampling techniques. Furthermore, a critical evaluation is conducted on the methodologies employed for the extraction and subsequent quantification of airborne pesticides. This analysis takes into consideration the complexities involved in ensuring accurate measurements, highlighting the advancements and limitations of current practices. By synthesizing these aspects, this review aims to foster a more comprehensive and informed comprehension of the intricate dynamics related to the presence and measurement of airborne pesticides. This, in turn, is poised to significantly contribute to the refinement of environmental monitoring strategies and the augmentation of precise risk assessments.
Collapse
Affiliation(s)
- Patchimaporn Udomkun
- Department of Environmental Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai 50200, Thailand; (P.U.); (T.B.); or (S.S.)
- Office of Research Administration, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Thirasant Boonupara
- Department of Environmental Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai 50200, Thailand; (P.U.); (T.B.); or (S.S.)
| | - Sulak Sumitsawan
- Department of Environmental Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai 50200, Thailand; (P.U.); (T.B.); or (S.S.)
| | - Eakalak Khan
- Civil and Environmental Engineering and Construction Department, University of Nevada, Las Vegas, NV 89154-4015, USA;
| | - Siwatt Pongpichan
- NIDA Center for Research and Development of Disaster Prevention and Management, Graduate School of Social Development and Management Strategy, National Institute of Development Administration (NIDA), Bangkok 10240, Thailand
| | - Puangrat Kajitvichyanukul
- Department of Environmental Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai 50200, Thailand; (P.U.); (T.B.); or (S.S.)
| |
Collapse
|
7
|
Kim PG, Lee A, Shin J, Song E, Koo Y, Mohamed DFMS, Choi S, Hong Y, Song S, Noh I, Kwon JH. Determination of terpene levels after the use of essential oil diffusers in vehicles and studio apartments using passive sampling. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 879:163071. [PMID: 36965723 DOI: 10.1016/j.scitotenv.2023.163071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/07/2023] [Accepted: 03/22/2023] [Indexed: 05/17/2023]
Abstract
The exposure levels of selected terpenes (limonene, α- and β-pinenes, and γ-terpinene) emitted by essential oil diffusers in vehicles and studio apartments were assessed using a passive sampling method. A previously developed passive sampler composed of an expanded polytetrafluoroethylene membrane and adsorbent (ePTFE PS) was enlarged and made wearable. Before field deployment, the sampling performance of the modified ePTFE PS for selected terpenes was compared with that of active sampling in a lab-scale 5 m3 test chamber under constant exposure conditions, supporting that passive sampling provides reasonable estimates of the time-weighted exposure concentration. Fifty volunteers were recruited and asked to wear the ePTFE PS while using an essential oil diffuser inside their own vehicle while commuting and in their studio apartment while sleeping. Terpene levels without an essential oil diffuser were very low in vehicles and 47, 3.6, 1.6, and 0.62 μg m-3 for average concentrations of limonene, α- and β-pinenes, and γ-terpinene in studio apartments, respectively, close to those reported in previous studies. The indoor concentrations of all selected terpenes in vehicles and studio apartments were elevated by the use of essential oil diffusers, especially in vehicles. The average concentration of limonene in vehicles after the use of essential oil diffusers was 11 μg m-3, which was greater than that before use by a factor of 30. Therefore, cautious usage of essential oil diffusers indoors where the volume is limited, such as a vehicle, is needed to reduce exposure to terpenes.
Collapse
Affiliation(s)
- Pil-Gon Kim
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Arum Lee
- Department of Consumer Science, Chungbuk National University, Cheongju 28644, Republic of Korea
| | - Jaeho Shin
- Department of Consumer Science, Chungbuk National University, Cheongju 28644, Republic of Korea
| | - Eugene Song
- Department of Consumer Science, Chungbuk National University, Cheongju 28644, Republic of Korea
| | - Yerim Koo
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Dana Fahad M S Mohamed
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Soobin Choi
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Yongseok Hong
- Department of Environmental Engineering, College of Science and Technology, Korea University Sejong Campus, Sejong City 30019, Republic of Korea
| | - Seokho Song
- Bio Division, Environmental Toxicity Center, Korea Conformity Laboratories, Incheon 21999, Republic of Korea
| | - Incheol Noh
- Environment Division, Chemical Analysis Center, Korea Conformity Laboratories, Seoul 08503, Republic of Korea
| | - Jung-Hwan Kwon
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea.
| |
Collapse
|
8
|
Moon JK, Kim PG, Lee KY, Kwon JH, Hong Y. Development of an in situ equilibrium polydimethylsiloxane passive sampler for measuring volatile organic compounds in soil vapor. CHEMOSPHERE 2023; 325:138419. [PMID: 36925016 DOI: 10.1016/j.chemosphere.2023.138419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 03/10/2023] [Accepted: 03/13/2023] [Indexed: 06/18/2023]
Abstract
An equilibrium passive sampler made of polydimethylsiloxane (PDMS) fiber was developed to measure volatile organic compounds (VOCs) in soil vapor. Expanded polytetrafluoroethylene (ePTFE) was used to protect PDMS from pollution and direct contact with soil components. For all tested VOCs, equilibrium was reached after 7 days at 5 °C. The equilibrium partition coefficients of VOCs between PDMS, gas, and water were measured at three different temperatures. The analyte concentrations in PDMS exposed to gas and water separately were almost the same, which suggests that Cgas and Cwater in soil pores can be accurately deduced from CPDMS after equilibrium at various temperatures. To evaluate the passive sampler, active sampling measurements were performed simultaneously. Concentrations of VOCs deduced from the passive sampler were consistent with the concentrations measured by active sampling near the 1:1 line. Tests with artificial soils were conducted to observe the effects of soil components on passive sampling. The results suggest that the effect of water saturation can be ignored; in other words, the developed passive sampler can be applied in the vadose zone, which has fluctuating water saturation. With a holder for the sampler made of stainless steel, the developed in situ passive sampler can measure VOCs in contaminated soil vapor. The developed passive sampler was proven to be an alternative for measuring VOCs in soil vapor, which can be helpful for soil risk assessment and for observing the diffusion of VOCs in contaminated sites.
Collapse
Affiliation(s)
- Jae-Kyoung Moon
- Department of Environmental Engineering, College of Science and Technology, Korea University Sejong Campus, Sejong City, 30019, Republic of Korea
| | - Pil-Gon Kim
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Keum Young Lee
- R&D Center, H-Plus Eco Ltd., 130-70, Jinsangmi-ro 813beon-gil, Seolseong-myeon, Icheon-si, 17412, Republic of Korea
| | - Jung-Hwan Kwon
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Yongseok Hong
- Department of Environmental Engineering, College of Science and Technology, Korea University Sejong Campus, Sejong City, 30019, Republic of Korea.
| |
Collapse
|
9
|
Figueiredo DM, Lô S, Krop E, Meijer J, Beeltje H, Lamoree MH, Vermeulen R. Do cats mirror their owner? Paired exposure assessment using silicone bands to measure residential PAH exposure. ENVIRONMENTAL RESEARCH 2023; 222:115412. [PMID: 36736760 DOI: 10.1016/j.envres.2023.115412] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 01/27/2023] [Accepted: 01/31/2023] [Indexed: 06/18/2023]
Abstract
It has been suggested that domestic animals can serve as sentinels for human exposures. In this study our objectives were to demonstrate that i) silicone collars can be used to measure environmental exposures of (domestic) animals, and that ii) domestic animals can be used as sentinels for human residential exposure. For this, we simultaneously measured polycyclic aromatic hydrocarbons (PAHs) using silicone bands worn by 30 pet cats (collar) and their owner (wristband). Collars and wristbands were worn for 7 days and analyzed via targeted Gas Chromatography-Mass Spectrometry (GC-MS). Demographics and daily routines were collected for humans and cats. Out of 16 PAHs, 9 were frequently detected (>50% of samples) in both wristbands and collars, of which Phenanthrene and Fluorene were detected in all samples. Concentrations of wristbands and collars were moderately correlated for these 9 PAHs (Median Spearman's r = 0.51 (range 0.16-0.68)). Determinants of PAH concentrations of cats and humans showed considerable overlap, with vacuum cleaning resulting in higher exposures and frequent changing of bed sheets in lower exposures. This study adds proof-of-principle data for the use of silicone collars to measure (domestic) animal exposure and shows that cats can be used as sentinels for human residential exposure.
Collapse
Affiliation(s)
- Daniel M Figueiredo
- Institute for Risk Assessment Sciences (IRAS), Utrecht University, Yalelaan 2, 3584 CM, Utrecht, the Netherlands.
| | - Serigne Lô
- Institute for Risk Assessment Sciences (IRAS), Utrecht University, Yalelaan 2, 3584 CM, Utrecht, the Netherlands
| | - Esmeralda Krop
- Institute for Risk Assessment Sciences (IRAS), Utrecht University, Yalelaan 2, 3584 CM, Utrecht, the Netherlands
| | - Jeroen Meijer
- Institute for Risk Assessment Sciences (IRAS), Utrecht University, Yalelaan 2, 3584 CM, Utrecht, the Netherlands; Department of Environment & Health, Faculty of Science, Amsterdam Institute for Life and Environment, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081 HV, Amsterdam, the Netherlands
| | - Henry Beeltje
- TNO Environmeral Modelling, Sensing & Analysis, Princetonlaan 8, 3584 CB, Utrecht, the Netherlands; AQUON, De Blomboogerd 12, 4003 BX, Tiel, the Netherlands
| | - Marja H Lamoree
- Department of Environment & Health, Faculty of Science, Amsterdam Institute for Life and Environment, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081 HV, Amsterdam, the Netherlands
| | - Roel Vermeulen
- Institute for Risk Assessment Sciences (IRAS), Utrecht University, Yalelaan 2, 3584 CM, Utrecht, the Netherlands
| |
Collapse
|
10
|
Matsukami H, Wannomai T, Uchida N, Tue NM, Hoang AQ, Tuyen LH, Viet PH, Takahashi S, Kunisue T, Suzuki G. Silicone wristband- and handwipe-based assessment of exposure to flame retardants for informal electronic-waste and end-of-life-vehicle recycling workers and their children in Vietnam. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 853:158669. [PMID: 36108870 DOI: 10.1016/j.scitotenv.2022.158669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Revised: 09/06/2022] [Accepted: 09/07/2022] [Indexed: 06/15/2023]
Abstract
Measuring personal exposure to flame retardants (FRs) is crucial for assessing and controlling human health risks posed by FRs during the recycling of electronic waste (e-waste) and end-of-life vehicles (ELVs). Here, we examined the use of handwipes and silicone wristbands to measure personal FR exposure for e-waste and ELV recycling workers and their children in Vietnam. On the handwipes from the e-waste recycling workers, the predominant five FRs detected were TBBPA (median concentration: 3700 ng/wipe), BDE-209 (1700 ng/wipe), TPHP (500 ng/wipe), DBDPE (410 ng/wipe), and BPA-BDPP (360 ng/wipe). On the handwipes from ELV recycling workers, TPHP (60 ng/wipe), IPPDPP (47 ng/wipe), BIPPPP/DIPPDPP (33 ng/wipe), BDE-209 (26 ng/wipe), and TCIPP (23 ng/wipe) were detected as the five predominant FRs. On the wristbands from the e-waste recycling workers, the five predominant FRs detected were TBBPA (median concentration: 340 ng/g), BDE-209 (330 ng/g), DBDPE (65 ng/g), TPHP (50 ng/g), and TMPP (34 ng/g). On the wristbands from the ELV recycling workers, TPHP (34 ng/g), IPPDPP (18 ng/g), TCIPP (14 ng/g), TDMPP (13 ng/g), BIPPPP/DIPPDPP (9.3 ng/g) and TMPP (9.3 ng/g) were detected as the predominant FRs. The data obtained with the wristbands were comparable to those obtained with the handwipes. Similar FR profiles were found in between the workers and their children. The profiles indicate that the informal e-waste and ELV recycling caused FR exposure not only for workers but also for their children who live in the workshops. By using the handwipe and wristband sampling approaches, we determined types and concentrations of FRs to which the workers and their children were dominantly exposed. Silicone wristband- and handwipe-based assessment is expected to be effective means of measuring personal FR exposure for the informal e-waste and ELV recycling workers and their children.
Collapse
Affiliation(s)
- Hidenori Matsukami
- Material Cycles Division, National Institute for Environmental Studies, Tsukuba 305-8506, Japan.
| | - Tatiya Wannomai
- Department of Transdisciplinary Science and Engineering, School of Environment and Society, Tokyo Institute of Technology, 4259, Nagatsuta, Midori-ku, Yokohama 226-8503, Japan
| | - Natsuyo Uchida
- Material Cycles Division, National Institute for Environmental Studies, Tsukuba 305-8506, Japan
| | - Nguyen Minh Tue
- Center for Marine Environmental Studies, Ehime University, 2-5 Bunkyo-cho, Matsuyama 790-8577, Japan; Key Laboratory of Analytical Technology for Environmental Quality and Food Safety Control, VNU University of Science, Vietnam National University, Hanoi, 334 Nguyen Trai, Hanoi 11400, Viet Nam
| | - Anh Quoc Hoang
- Center of Advanced Technology for the Environment, Faculty of Agriculture, Ehime University, 3-5-7 Tarumi, Matsuyama 790-8566, Japan; Faculty of Chemistry, VNU University of Science, Vietnam National University, Hanoi, 19 Le Thanh Tong, Hanoi 11000, Viet Nam
| | - Le Huu Tuyen
- Key Laboratory of Analytical Technology for Environmental Quality and Food Safety Control, VNU University of Science, Vietnam National University, Hanoi, 334 Nguyen Trai, Hanoi 11400, Viet Nam
| | - Pham Hung Viet
- Key Laboratory of Analytical Technology for Environmental Quality and Food Safety Control, VNU University of Science, Vietnam National University, Hanoi, 334 Nguyen Trai, Hanoi 11400, Viet Nam
| | - Shin Takahashi
- Center of Advanced Technology for the Environment, Faculty of Agriculture, Ehime University, 3-5-7 Tarumi, Matsuyama 790-8566, Japan
| | - Tatsuya Kunisue
- Center for Marine Environmental Studies, Ehime University, 2-5 Bunkyo-cho, Matsuyama 790-8577, Japan
| | - Go Suzuki
- Material Cycles Division, National Institute for Environmental Studies, Tsukuba 305-8506, Japan
| |
Collapse
|
11
|
Samon SM, Hammel SC, Stapleton HM, Anderson KA. Silicone wristbands as personal passive sampling devices: Current knowledge, recommendations for use, and future directions. ENVIRONMENT INTERNATIONAL 2022; 169:107339. [PMID: 36116363 PMCID: PMC9713950 DOI: 10.1016/j.envint.2022.107339] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 06/03/2022] [Accepted: 06/06/2022] [Indexed: 05/13/2023]
Abstract
Personal chemical exposure assessment is necessary to determine the frequency and magnitude of individual chemical exposures, especially since chemicals present in everyday environments may lead to adverse health outcomes. In the last decade, silicone wristbands have emerged as a new chemical exposure assessment tool and have since been utilized for assessing personal exposure to a wide range of chemicals in a variety of populations. Silicone wristbands can be powerful tools for quantifying personal exposure to chemical mixtures in a single sample, associating exposure with health outcomes, and potentially overcoming some of the challenges associated with quantifying the chemical exposome. However, as their popularity grows, it is crucial that they are used in the appropriate context and within the limits of the technology. This review serves as a guide for researchers interested in utilizing silicone wristbands as a personal exposure assessment tool. Along with briefly discussing the passive sampling theory behind silicone wristbands, this review performs an in-depth comparison of wristbands to other common exposure assessment tools, including biomarkers of exposure measured in biospecimens, and evaluates their utility in exposure assessments and epidemiological studies. Finally, this review includes recommendations for utilizing silicone wristbands to evaluate personal chemical exposure and provides suggestions on what research is needed to recognize silicone wristbands as a premier chemical exposure assessment tool.
Collapse
Affiliation(s)
- Samantha M Samon
- Department of Environmental & Molecular Toxicology, Oregon State University, Corvallis, OR, United States
| | - Stephanie C Hammel
- The National Research Centre for the Working Environment, Copenhagen, Denmark
| | - Heather M Stapleton
- Nicholas School of the Environment, Duke University, Durham, NC, United States
| | - Kim A Anderson
- Department of Environmental & Molecular Toxicology, Oregon State University, Corvallis, OR, United States.
| |
Collapse
|
12
|
Unconventional and user-friendly sampling techniques of semi-volatile organic compounds present in an indoor environment: An approach to human exposure assessment. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116669] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
13
|
Wacławik M, Rodzaj W, Wielgomas B. Silicone Wristbands in Exposure Assessment: Analytical Considerations and Comparison with Other Approaches. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19041935. [PMID: 35206121 PMCID: PMC8872583 DOI: 10.3390/ijerph19041935] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 01/28/2022] [Accepted: 02/05/2022] [Indexed: 02/06/2023]
Abstract
Humans are exposed to numerous potentially harmful chemicals throughout their lifetime. Although many studies have addressed this issue, the data on chronic exposure is still lacking. Hence, there is a growing interest in methods and tools allowing to longitudinally track personal exposure to multiple chemicals via different routes. Since the seminal work, silicone wristbands (WBs) have been increasingly used to facilitate human exposure assessment, as using WBs as a wearable sampler offers new insights into measuring chemical risks involved in many ambient and occupational scenarios. However, the literature lacks a detailed overview regarding methodologies being used; a comprehensive comparison with other approaches of personal exposure assessment is needed as well. Therefore, the aim of this review is fourfold. First, we summarize hitherto conducted research that employed silicone WBs as personal passive samplers. Second, all pre-analytical and analytical steps used to obtain exposure data are discussed. Third, we compare main characteristics of WBs with key features of selected matrices used in exposure assessment, namely urine, blood, hand wipes, active air sampling, and settled dust. Finally, we discuss future needs of research employing silicone WBs. Our work shows a variety of possibilities, advantages, and caveats associated with employment of silicone WBs as personal passive samplers. Although further research is necessary, silicone WBs have already been proven valuable as a tool for longitudinal assessment of personal exposure.
Collapse
|
14
|
Fuentes ZC, Schwartz YL, Robuck AR, Walker DI. Operationalizing the Exposome Using Passive Silicone Samplers. CURRENT POLLUTION REPORTS 2022; 8:1-29. [PMID: 35004129 PMCID: PMC8724229 DOI: 10.1007/s40726-021-00211-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 12/11/2021] [Indexed: 05/15/2023]
Abstract
The exposome, which is defined as the cumulative effect of environmental exposures and corresponding biological responses, aims to provide a comprehensive measure for evaluating non-genetic causes of disease. Operationalization of the exposome for environmental health and precision medicine has been limited by the lack of a universal approach for characterizing complex exposures, particularly as they vary temporally and geographically. To overcome these challenges, passive sampling devices (PSDs) provide a key measurement strategy for deep exposome phenotyping, which aims to provide comprehensive chemical assessment using untargeted high-resolution mass spectrometry for exposome-wide association studies. To highlight the advantages of silicone PSDs, we review their use in population studies and evaluate the broad range of applications and chemical classes characterized using these samplers. We assess key aspects of incorporating PSDs within observational studies, including the need to preclean samplers prior to use to remove impurities that interfere with compound detection, analytical considerations, and cost. We close with strategies on how to incorporate measures of the external exposome using PSDs, and their advantages for reducing variability in exposure measures and providing a more thorough accounting of the exposome. Continued development and application of silicone PSDs will facilitate greater understanding of how environmental exposures drive disease risk, while providing a feasible strategy for incorporating untargeted, high-resolution characterization of the external exposome in human studies.
Collapse
Affiliation(s)
- Zoe Coates Fuentes
- Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, 1428 Madison Ave, New York, NY USA
| | - Yuri Levin Schwartz
- Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, 1428 Madison Ave, New York, NY USA
| | - Anna R. Robuck
- Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, 1428 Madison Ave, New York, NY USA
| | - Douglas I. Walker
- Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, 1428 Madison Ave, New York, NY USA
| |
Collapse
|
15
|
Akanyange SN, Lyu X, Zhao X, Li X, Zhang Y, Crittenden JC, Anning C, Chen T, Jiang T, Zhao H. Does microplastic really represent a threat? A review of the atmospheric contamination sources and potential impacts. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 777:146020. [PMID: 33677289 DOI: 10.1016/j.scitotenv.2021.146020] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 02/14/2021] [Accepted: 02/16/2021] [Indexed: 06/12/2023]
Abstract
Microplastics (MPs) are regarded as one of the major atmospheric contaminants that have gained wide attention across the globe in the current dispensation. Airborne MPs have been collected in atmospheric fallouts, in indoor and outdoor air as well as along roadways and indoor dust. The most dominating constituent shapes and forms of identified airborne MPs are fibers and synthetic textiles, respectively. With the breathing mechanism as a spontaneous practice for survival, the inhalation of airborne MPs is an inevitable deal. The level of toxicity of MPs to organisms stems from its physiochemical speciation. The smaller size and almost weightless nature make it possible to suspend in the atmosphere and be inhaled and create potential health problems. Nonetheless, the data available concerning the presence of airborne MPs and its environmental and human health impacts is limited. In this review, we extensively discuss the rigorous and suitable methodologies adopted for the analysis of airborne MPs in previous studies. The characteristics and sources of airborne MPs, the potential health impacts on humans, and some mitigating measures have also been discussed thoroughly.
Collapse
Affiliation(s)
- Stephen Nyabire Akanyange
- College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266000, China
| | - Xianjun Lyu
- College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266000, China
| | - Xiaohan Zhao
- College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266000, China
| | - Xue Li
- College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266000, China
| | - Yan Zhang
- College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266000, China.
| | - John C Crittenden
- School of Civil and Environmental Engineering, Georgia Institute of Technology, 828 W. Peachtree Street, Suite 320, Atlanta, GA 30332-0595, USA
| | - Cosmos Anning
- College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266000, China
| | - Tianpeng Chen
- College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266000, China
| | - Tianlin Jiang
- College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266000, China
| | - Huaqing Zhao
- College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266000, China
| |
Collapse
|
16
|
Chan W, Jin L, Sun Z, Griffith SM, Yu JZ. Fabric Masks as a Personal Dosimeter for Quantifying Exposure to Airborne Polycyclic Aromatic Hydrocarbons. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:5128-5135. [PMID: 33710865 DOI: 10.1021/acs.est.0c08327] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
In this study, we assessed the feasibility of using ordinary face masks as a sampling means to collect airborne polycyclic aromatic hydrocarbons (PAHs). Nonwoven fabric masks can trap three-ring or larger PAHs at a high efficiency (>70%) and naphthalene at ∼17%. The sampling method is quantitative as confirmed by comparison with the standard method of the National Institute for Occupational Safety and Health. In conjunction with sensitive fluorescence detection, the method was applied to quantify nine airborne PAHs in a range of indoor and outdoor environments. Wearing the mask for 2 h allowed quantification of individual PAHs as low as 0.07 ng/m3. The demonstration shows applicability of the method in monitoring PAHs down to ∼30-80 ng/m3 in university office and laboratory settings and up to ∼900 ng/m3 in an incense-burning temple. Compared with traditional filter-/sorbent tube-based approaches, which require a sampling pump, our new method is simple, convenient, and inexpensive. More importantly, it closely tracks human exposure down to the individual level, thus having great potential to facilitate routine occupational exposure monitoring and large-scale surveillance of PAH concentrations in indoor and outdoor environments.
Collapse
Affiliation(s)
- Wan Chan
- Department of Chemistry and Division of Environment, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Long Jin
- Department of Chemistry and Division of Environment, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Zhihan Sun
- Department of Chemistry and Division of Environment, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Stephen M Griffith
- Department of Atmospheric Sciences, National Central University, Taoyuan 32001, Taiwan
| | - Jian Zhen Yu
- Department of Chemistry and Division of Environment, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| |
Collapse
|
17
|
Baum JLR, Bakali U, Killawala C, Santiago KM, Dikici E, Kobetz EN, Solle NS, Deo S, Bachas L, Daunert S. Evaluation of silicone-based wristbands as passive sampling systems using PAHs as an exposure proxy for carcinogen monitoring in firefighters: Evidence from the firefighter cancer initiative. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2020; 205:111100. [PMID: 32911453 DOI: 10.1016/j.ecoenv.2020.111100] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 07/25/2020] [Accepted: 07/28/2020] [Indexed: 05/23/2023]
Abstract
Compared to the general population, firefighters are known to sustain greater levels of exposure to hazardous compounds, despite their personal protective equipment, also known as turnout gear. Among the most significant toxins that firefighters are chronically exposed to are polycyclic aromatic hydrocarbons (PAHs). Additionally, firefighters have also been noted to exhibit an increased incidence of certain types of cancer. Considering a probable link between exposure to PAHs and increased rates of cancer in the fire service, we aim to document ambient chemical concentrations in the firefighter work environment. Our strategy involves the use of silicone-based wristbands that have the capacity to passively sorb PAHs. To determine if wristbands can serve as an effective chemical monitoring device for the fire service, silicone wristbands were pilot-tested as personal sampling devices for work environment risk monitoring in active-duty firefighters. Recovered wristbands underwent multiple extraction steps, followed by GC-MS analysis to demonstrate their efficacy in monitoring PAHs in the firefighter environment. Initial findings from all wristband samples taken from firefighters showed multiple exposures to various PAHs of concern for the health of the firefighters when in a fire environment. In addition to PAH monitoring, we examined known and potential sources of PAH contamination in their work environment. To that end, profiles of elevated PAH concentrations were documented at various fire stations throughout South Florida, for individual firefighters both during station duties and active fire response.
Collapse
Affiliation(s)
- Jeramy L R Baum
- Chemistry, University of Miami, Coral Gables, FL, USA; Biochemistry and Molecular Biology, University of Miami, Miller School of Medicine, Miami, FL, USA
| | - Umer Bakali
- Biochemistry and Molecular Biology, University of Miami, Miller School of Medicine, Miami, FL, USA
| | - Chitvan Killawala
- Biochemistry and Molecular Biology, University of Miami, Miller School of Medicine, Miami, FL, USA; Biomedical Engineering, University of Miami, Coral Gables, FL, USA
| | - Katerina M Santiago
- Public Health Sciences, University of Miami, Miller School of Medicine, Miami, FL, USA
| | - Emre Dikici
- Biochemistry and Molecular Biology, University of Miami, Miller School of Medicine, Miami, FL, USA
| | - Erin N Kobetz
- Public Health Sciences, University of Miami, Miller School of Medicine, Miami, FL, USA; Medicine, University of Miami, Miller School of Medicine, Miami, FL, USA; Sylvester Comprehensive Cancer Center, Miami, FL, USA
| | - Natasha Schaefer Solle
- Medicine, University of Miami, Miller School of Medicine, Miami, FL, USA; Sylvester Comprehensive Cancer Center, Miami, FL, USA
| | - Sapna Deo
- Biochemistry and Molecular Biology, University of Miami, Miller School of Medicine, Miami, FL, USA; Sylvester Comprehensive Cancer Center, Miami, FL, USA
| | | | - Sylvia Daunert
- Biochemistry and Molecular Biology, University of Miami, Miller School of Medicine, Miami, FL, USA; Sylvester Comprehensive Cancer Center, Miami, FL, USA.
| |
Collapse
|
18
|
Wania F, Shunthirasingham C. Passive air sampling for semi-volatile organic chemicals. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2020; 22:1925-2002. [PMID: 32822447 DOI: 10.1039/d0em00194e] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
During passive air sampling, the amount of a chemical taken up in a sorbent from the air without the help of a pump is quantified and converted into an air concentration. In an equilibrium sampler, this conversion requires a thermodynamic parameter, the equilibrium sorption coefficient between gas-phase and sorbent. In a kinetic sampler, a time-averaged air concentration is obtained using a sampling rate, which is a kinetic parameter. Design requirements for kinetic and equilibrium sampling conflict with each other. The volatility of semi-volatile organic compounds (SVOCs) varies over five orders of magnitude, which implies that passive air samplers are inevitably kinetic samplers for less volatile SVOCs and equilibrium samplers for more volatile SVOCs. Therefore, most currently used passive sampler designs for SVOCs are a compromise that requires the consideration of both a thermodynamic and a kinetic parameter. Their quantitative interpretation depends on assumptions that are rarely fulfilled, and on input parameters, that are often only known with high uncertainty. Kinetic passive air sampling for SVOCs is also challenging because their typically very low atmospheric concentrations necessitate relatively high sampling rates that can only be achieved without the use of diffusive barriers. This in turn renders sampling rates dependent on wind conditions and therefore highly variable. Despite the overall high uncertainty arising from these challenges, passive air samplers for SVOCs have valuable roles to play in recording (i) spatial concentration variability at scales ranging from a few centimeters to tens of thousands of kilometers, (ii) long-term trends, (iii) air contamination in remote and inaccessible locations and (iv) indoor inhalation exposure. Going forward, thermal desorption of sorbents may lower the detection limits for some SVOCs to an extent that the use of diffusive barriers in the kinetic sampling of SVOCs becomes feasible, which is a prerequisite to decreasing the uncertainty of sampling rates. If the thermally stable sorbent additionally has a high sorptive capacity, it may be possible to design true kinetic samplers for most SVOCs. In the meantime, the passive air sampling community would benefit from being more transparent by rigorously quantifying and explicitly reporting uncertainty.
Collapse
Affiliation(s)
- Frank Wania
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario M1C 1A4, Canada.
| | | |
Collapse
|
19
|
Advances in Comprehensive Exposure Assessment: Opportunities for the US Military. J Occup Environ Med 2020; 61 Suppl 12:S5-S14. [PMID: 31800446 DOI: 10.1097/jom.0000000000001677] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
OBJECTIVE Review advances in exposure assessment offered by the exposome concept and new -omics and sensor technologies. METHODS Narrative review of advances, including current efforts and potential future applications by the US military. RESULTS Exposure assessment methods from both bottom-up and top-down exposomics approaches are advancing at a rapid pace, and the US military is engaged in developing both approaches. Top-down approaches employ various -omics technologies to identify biomarkers of internal exposure and biological effect. Bottom-up approaches use new sensor technology to better measure external dose. Key challenges of both approaches are largely centered around how to integrate, analyze, and interpret large datasets that are multidimensional and disparate. CONCLUSIONS Advances in -omics and sensor technologies may dramatically enhance exposure assessment and improve our ability to characterize health risks related to occupational and environmental exposures, including for the US military.
Collapse
|
20
|
Reddam A, Tait G, Herkert N, Hammel SC, Stapleton HM, Volz DC. Longer commutes are associated with increased human exposure to tris(1,3-dichloro-2-propyl) phosphate. ENVIRONMENT INTERNATIONAL 2020; 136:105499. [PMID: 31999975 PMCID: PMC7061053 DOI: 10.1016/j.envint.2020.105499] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 01/15/2020] [Accepted: 01/15/2020] [Indexed: 05/21/2023]
Abstract
Organophosphate esters (OPEs) are a class of semi-volatile organic compounds (SVOCs) used as flame retardants, plasticizers, and anti-foaming agents. Due to stringent flammability standards in vehicles and the ability of OPEs to migrate out of end-use products, elevated concentrations of OPEs have been found in car dust samples around the world. As many residents of Southern California spend a significant amount of time in their vehicles, there is potential for increased exposure to OPEs associated with longer commute times. As approximately 70% of the University of California, Riverside's undergraduate population commutes, the objective of this study was to use silicone wristbands to monitor personal exposure to OPEs and determine if exposure was associated with commute time in a subset of these students. Participants were asked to wear wristbands for five continuous days and complete daily surveys about the amount of time spent commuting. Data were then used to calculate a participant-specific total commute score. Components of Firemaster 550 (triphenyl phosphate, or TPHP, and isopropylated triaryl phosphate isomers) and Firemaster 600 (TPHP and tert-butylated triaryl phosphate isomers) - both widely used commercial flame retardant formulations - were strongly correlated with other OPEs detected within participant wristbands. Moreover, the concentration of tris(1,3-dichloro-2-propyl) phosphate (TDCIPP) was significantly correlated with the concentration of several Firemaster 500 components and tris(2-chloroisopropyl) phosphate (TCIPP). Finally, out of all OPEs measured, TDCIPP was significantly and positively correlated with total commute score, indicating that longer commutes are associated with increased human exposure to TDCIPP. Overall, our findings raise concerns about the potential for chronic TDCIPP exposure within vehicles and other forms of transportation, particularly within densely populated and traffic-congested areas such as Southern California.
Collapse
Affiliation(s)
- Aalekhya Reddam
- Environmental Toxicology Graduate Program, University of California, Riverside, CA, USA; Department of Environmental Sciences, University of California, Riverside, CA, USA
| | - George Tait
- Nicholas School of the Environment, Duke University, Durham, NC, USA
| | - Nicholas Herkert
- Nicholas School of the Environment, Duke University, Durham, NC, USA
| | | | | | - David C Volz
- Department of Environmental Sciences, University of California, Riverside, CA, USA.
| |
Collapse
|
21
|
Hendryx M, Wang S, Romanak KA, Salamova A, Venier M. Personal exposure to polycyclic aromatic hydrocarbons in Appalachian mining communities. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2020; 257:113501. [PMID: 31706774 PMCID: PMC6981027 DOI: 10.1016/j.envpol.2019.113501] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 10/25/2019] [Accepted: 10/26/2019] [Indexed: 05/07/2023]
Abstract
Coal mining activities may increase residential exposure to polycyclic aromatic hydrocarbons (PAHs), but personal PAH exposures have not been studied in mining areas. We used silicone wristbands as passive personal samplers to estimate PAH exposures in coal mining communities in Central Appalachia in the United States. Adults (N = 101) wore wristbands for one week; 51 resided in communities within approximately three miles of surface mining sites, and 50 resided 10 or more miles from mining sites. Passive indoor polyurethane foam (PUF) sampling was conducted in residents' homes, and a sample of 16 outdoor PUF samples were also collected. Nine PAH congeners were commonly detected in wristbands (mean ± standard deviation), including phenanthrene (50.2 ± 68.7 ng/g), benz[a]anthracene (20.2 ± 58.2 ng/g), fluoranthene (19.4 ± 24.1 ng/g) and pyrene (15.2 ± 18.2 ng/g). Controlling for participant characteristics and season, participants living closer to mining sites had significantly higher levels of phenanthrene, fluorene, fluoranthene, pyrene and ∑PAHs in wristbands compared to participants living farther from mining. Indoor air showed no significant group differences except for pyrene, but outdoor air showed significant or marginally significant differences for phenanthrene, fluorene, pyrene and ∑PAHs. The results suggest that mining community residents face exposure to outdoor mining-related pollutants, and demonstrate that personal silicone wristbands can be deployed as effective passive sampling devices.
Collapse
Affiliation(s)
- Michael Hendryx
- Department of Environmental and Occupational Health, School of Public Health, Indiana University, 1025 E, 7th St., Bloomington, USA.
| | - Shaorui Wang
- O'Neill School of Public and Environmental Affairs, Indiana University, Bloomington, IN, 47405, USA
| | - Kevin A Romanak
- O'Neill School of Public and Environmental Affairs, Indiana University, Bloomington, IN, 47405, USA
| | - Amina Salamova
- O'Neill School of Public and Environmental Affairs, Indiana University, Bloomington, IN, 47405, USA
| | - Marta Venier
- O'Neill School of Public and Environmental Affairs, Indiana University, Bloomington, IN, 47405, USA
| |
Collapse
|
22
|
Matatiele P, Mochaki L, Southon B, Dabula B, Poongavanum P, Kgarebe B. Environmental and biological monitoring in the workplace: A 10-year South African retrospective analysis. AAS Open Res 2019; 1:20. [PMID: 32382697 PMCID: PMC7194147 DOI: 10.12688/aasopenres.12882.2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/10/2019] [Indexed: 11/20/2022] Open
Abstract
This report is an overview of requests for biological and environmental monitoring of hazardous chemicals, submitted to the National Institute for Occupational Health, Analytical Services Laboratory for testing from the years 2005 to 2015. The report discusses the nature of tests requested and implications for workers’ health and environment, as well as potential impact of the uncertainties associated with monitoring of hazardous chemicals. This is a retrospective, descriptive, qualitative and quantitative audit of all samples received and tests performed retrieved from records of analysis by the laboratory. The study sample consisted of 44,221 samples. The report indicates that throughout the interrogation period the demand for biological monitoring was higher than that for environmental monitoring, with more requests for toxic metals than organic pollutants. Toxic metal testing was highest for mercury, followed by manganese, lead, aluminium and arsenic. The highest number of tests for organic pollutants was conducted for pesticides followed by toluene and xylene. The study has also revealed that the scope of tests requested is rather narrow and does not reflect the broad spectrum of
South Africa’s industrial diversity. Having identified possible reasons for underutilization, a number of reforms that could enhance the laboratory’s performance have been addressed.
Collapse
Affiliation(s)
- Puleng Matatiele
- Analytical Services, National Institute for Occupational Health, Johannesburg, Gauteng, 2000, South Africa
| | - Lerato Mochaki
- Analytical Services, National Institute for Occupational Health, Johannesburg, Gauteng, 2000, South Africa
| | - Bianca Southon
- Analytical Services, National Institute for Occupational Health, Johannesburg, Gauteng, 2000, South Africa
| | - Boitumelo Dabula
- Analytical Services, National Institute for Occupational Health, Johannesburg, Gauteng, 2000, South Africa
| | - Poobalan Poongavanum
- Analytical Services, National Institute for Occupational Health, Johannesburg, Gauteng, 2000, South Africa
| | - Boitumelo Kgarebe
- Analytical Services, National Institute for Occupational Health, Johannesburg, Gauteng, 2000, South Africa.,African Academy of Sciences, Nairobi, Kenya
| |
Collapse
|
23
|
Rohlman D, Dixon HM, Kincl L, Larkin A, Evoy R, Barton M, Phillips A, Peterson E, Scaffidi C, Herbstman JB, Waters KM, Anderson KA. Development of an environmental health tool linking chemical exposures, physical location and lung function. BMC Public Health 2019; 19:854. [PMID: 31262274 PMCID: PMC6604385 DOI: 10.1186/s12889-019-7217-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2018] [Accepted: 06/20/2019] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND A challenge in environmental health research is collecting robust data sets to facilitate comparisons between personal chemical exposures, the environment and health outcomes. To address this challenge, the Exposure, Location and lung Function (ELF) tool was designed in collaboration with communities that share environmental health concerns. These concerns centered on respiratory health and ambient air quality. The ELF collects exposure to polycyclic aromatic hydrocarbons (PAHs), given their association with diminished lung function. Here, we describe the ELF as a novel environmental health assessment tool. METHODS The ELF tool collects chemical exposure for 62 PAHs using passive sampling silicone wristbands, geospatial location data and respiratory lung function measures using a paired hand-held spirometer. The ELF was tested by 10 individuals with mild to moderate asthma for 7 days. Participants wore a wristband each day to collect PAH exposure, carried a cell phone, and performed spirometry daily to collect respiratory health measures. Location data was gathered using the geospatial positioning system technology in an Android cell-phone. RESULTS We detected and quantified 31 PAHs across the study population. PAH exposure data showed spatial and temporal sensitivity within and between participants. Location data was used with existing datasets such as the Toxics Release Inventory and the National Oceanic and Atmospheric Administration (NOAA) Hazard Mapping System. Respiratory health outcomes were validated using criteria from the American Thoracic Society with 94% of participant data meeting standards. Finally, the ELF was used with a high degree of compliance (> 90%) by community members. CONCLUSIONS The ELF is a novel environmental health assessment tool that allows for personal data collection spanning chemical exposures, location and lung function measures as well as self-reported information.
Collapse
Affiliation(s)
- Diana Rohlman
- College of Public Health and Human Sciences; Superfund Research Program, Oregon State University, 101 Milam Hall, Corvallis, Oregon USA
| | - Holly M. Dixon
- Environmental and Molecular Toxicology, Food Safety and Environmental Stewardship Program, Oregon State University, Corvallis, Oregon USA
| | - Laurel Kincl
- College of Public Health and Human Sciences, Oregon State University, Corvallis, Oregon USA
| | - Andrew Larkin
- College of Public Health and Human Sciences, Oregon State University, Corvallis, Oregon USA
| | - Richard Evoy
- College of Public Health and Human Sciences, Oregon State University, Corvallis, Oregon USA
| | - Michael Barton
- Superfund Research Program, Food Safety and Environmental Stewardship Program, Oregon State University, Corvallis, Oregon USA
| | - Aaron Phillips
- Computing & Analytics Division, Pacific Northwest National Laboratory, Richland, Washington USA
| | - Elena Peterson
- Computing & Analytics Division, Pacific Northwest National Laboratory, Richland, Washington USA
| | | | - Julie B. Herbstman
- Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York City, USA
| | - Katrina M. Waters
- Biological Sciences Division, Pacific Northwest National Laboratory, Pacific Northwest National Laboratory, Richland, WA USA
| | - Kim A. Anderson
- Environmental and Molecular Toxicology, Food Safety and Environmental Stewardship Program, Oregon State University, Corvallis, Oregon USA
| |
Collapse
|
24
|
Jung Y, Kim PG, Kwon JH. Inhalation risk assessment of naphthalene emitted from deodorant balls in public toilets. ENVIRONMENTAL HEALTH AND TOXICOLOGY 2019; 34:e2019005. [PMID: 31286749 PMCID: PMC6620615 DOI: 10.5620/eht.e2019005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/13/2019] [Accepted: 06/19/2019] [Indexed: 06/09/2023]
Abstract
The inhalation of naphthalene used as deodorant balls in public toilets could be an important cancer risk factor. The atmospheric concentration of naphthalene in public toilets (Cin) was estimated both by a polyurethane foam passive air sampler (PUF-PAS) deployed in nine public toilets in Seoul, Korea and by a steady-state indoor air quality model, including emission estimation using Monte-Carlo simulation. Based on the estimated Cin, cancer risk was also assessed for cleaning workers and the general population. The steady-state Cin estimated using the estimated emission rate, which assumed that air exchange was the only process by which naphthalene was removed, was much greater than the Cin value measured using PUF-PAS in nine public toilets, implying the importance of other removal processes, such as sorption to walls and the garments of visitors, as well as decreased emission rate owing to wetting of the naphthalene ball surface. The 95 percentile values of cancer risk for workers based on the estimation by PUF-PAS was 1.6×10-6 , whereas those for the general public were lower than 1×10-6 . The results suggested that naphthalene deodorant balls in public toilets may be an important cancer risk factor especially for the cleaning workers.
Collapse
Affiliation(s)
- Yerin Jung
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Korea
| | - Pil-Gon Kim
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Korea
| | - Jung-Hwan Kwon
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Korea
| |
Collapse
|
25
|
Manzano CA, Dodder NG, Hoh E, Morales R. Patterns of Personal Exposure to Urban Pollutants Using Personal Passive Samplers and GC × GC/ToF-MS. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:614-624. [PMID: 30575390 DOI: 10.1021/acs.est.8b06220] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The performance of silicon wristband passive samplers (WB), combined with comprehensive two-dimensional gas-chromatography/time-of-flight mass-spectrometry (GC × GC/ToF-MS), for the analysis of urban derived pollutants in the personal environment was evaluated. Cumulative 5-day exposure samples from 27 individuals in areas with different geographical/socioeconomic characteristics within the Santiago Metropolitan Region (Chile) were collected during winter and summer (2016-2017). Samples were extracted without cleanup/fractionation and analyzed using targeted and nontargeted methods. The quantified semivolatile organic compounds (SVOCs, n = 33) (targeted analysis), and tentatively identified features ( n = 595-1011) (nontargeted analysis) were classified according to their use/source. Seasonal differences were observed in the targeted analysis, while seasonal and spatial differences were observed in the nontargeted analysis. Higher concentrations of combustion products were observed in winter, while higher concentrations of consumer products were found in summer. Spatial differences were observed in hierarchical clustering analysis of the nontargeted data, with distinct clusters corresponding to specific subregions of the urban area. Results from this study provide spatial and seasonal distributions of urban pollutants within an urban area and establish the utility of linking WB with nontargeted analysis as a tool to identify and prioritize new exposures to urban contaminants at the local/community level.
Collapse
Affiliation(s)
- Carlos A Manzano
- Center for Environmental Science, Faculty of Science , Universidad de Chile , Santiago , Chile
- School of Public Health , San Diego State University , San Diego , California United States
| | - Nathan G Dodder
- School of Public Health , San Diego State University , San Diego , California United States
- San Diego State University Research Foundation , San Diego , California United States
| | - Eunha Hoh
- School of Public Health , San Diego State University , San Diego , California United States
| | - Raul Morales
- Center for Environmental Science, Faculty of Science , Universidad de Chile , Santiago , Chile
| |
Collapse
|
26
|
Hammel SC, Phillips AL, Hoffman K, Stapleton HM. Evaluating the Use of Silicone Wristbands To Measure Personal Exposure to Brominated Flame Retardants. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2018; 52:11875-11885. [PMID: 30216050 PMCID: PMC6445795 DOI: 10.1021/acs.est.8b03755] [Citation(s) in RCA: 52] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Biomarkers remain the gold standard for assessing chemical exposure. However, silicone wristbands may provide some added benefits for characterizing personal exposures compared to single biomarker measurements, such as decreased costs, noninvasive sampling, and increased ease of analysis. Previously, we validated their use in characterizing exposure to organophosphate flame retardants (PFRs). However, it is unclear whether these results would extend to chemicals like polybrominated diphenyl ethers (PBDEs), which biomagnify and have longer half-lives than PFRs in the body. This study sought to determine if accumulation of PBDEs on wristbands was correlated to serum biomarkers. Adult participants ( n = 30) provided serum samples and wore wristbands for 7 days. PBDEs and 6 novel brominated flame retardants (BFRs) were measured on wristbands, and serum samples were analyzed for PBDE biomarkers. Like most PBDE congeners, 5 of 6 novel BFRs were frequently detected on wristbands (≥90% of bands). In particular, decabromodiphenyl ethane (DBDPE) was detected in all wristbands in this study and was significantly correlated with BDE-209, suggesting a similar source and exposure pathway. Wristband levels of BDE-47, -99, -100, and -153 were significantly and positively associated with respective serum biomarkers ( rs = 0.39-0.57, p < 0.05). This study demonstrates that silicone wristbands can accurately detect personal PBDE exposures.
Collapse
|
27
|
Sha B, Dahlberg AK, Wiberg K, Ahrens L. Fluorotelomer alcohols (FTOHs), brominated flame retardants (BFRs), organophosphorus flame retardants (OPFRs) and cyclic volatile methylsiloxanes (cVMSs) in indoor air from occupational and home environments. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2018; 241:319-330. [PMID: 29843014 DOI: 10.1016/j.envpol.2018.04.032] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 04/04/2018] [Accepted: 04/05/2018] [Indexed: 06/08/2023]
Abstract
Indoor air samples were collected from private homes and various occupational indoor environments using passive air sampler and analysed for fluorotelomer alcohols (FTOHs), brominated flame retardants (BFRs), organophosphorus flame retardants (OPFRs) and cyclic volatile methyl siloxanes (cVMSs). The aim was to investigate their occurrence in indoor air, factors that may affect their presence and human daily exposure dose (DED) via inhalation. In general, levels of cVMSs were 3-4 orders of magnitude greater than the other compound classes. OPFRs concentration was found significantly higher than BFRs in indoor air. The most abundant compounds in each chemical class were 8:2 FTOH, 2,4,6-TBP, TNBP and TCEP and decamethylcyclopentasiloxane (D5). Home samples contained higher level of FTOHs, BFRs and cVMSs than occupational environments, whereas concentration of OPFRs in office samples were higher. BFRs concentrations were significantly correlated with building age and with the number of electronic/electrical devices at the sampling sites. Moreover, significantly lower levels of FTOHs and cVMSs were observed in rooms with forced-ventilation system. Estimated DED via inhalation was significantly higher at home than in office and the total DED was on average 3-5 orders of magnitude lower than the reference value.
Collapse
Affiliation(s)
- Bo Sha
- Swedish University of Agricultural Sciences (SLU), Department of Aquatic Sciences and Assessment, SE-75007 Uppsala, Sweden
| | - Anna-Karin Dahlberg
- Swedish University of Agricultural Sciences (SLU), Department of Aquatic Sciences and Assessment, SE-75007 Uppsala, Sweden
| | - Karin Wiberg
- Swedish University of Agricultural Sciences (SLU), Department of Aquatic Sciences and Assessment, SE-75007 Uppsala, Sweden
| | - Lutz Ahrens
- Swedish University of Agricultural Sciences (SLU), Department of Aquatic Sciences and Assessment, SE-75007 Uppsala, Sweden.
| |
Collapse
|
28
|
Paulik LB, Hobbie KA, Rohlman D, Smith BW, Scott RP, Kincl L, Haynes EN, Anderson KA. Environmental and individual PAH exposures near rural natural gas extraction. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2018; 241:397-405. [PMID: 29857308 PMCID: PMC7169985 DOI: 10.1016/j.envpol.2018.05.010] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Revised: 05/02/2018] [Accepted: 05/03/2018] [Indexed: 05/19/2023]
Abstract
Natural gas extraction (NGE) has expanded rapidly in the United States in recent years. Despite concerns, there is little information about the effects of NGE on air quality or personal exposures of people living or working nearby. Recent research suggests NGE emits polycyclic aromatic hydrocarbons (PAHs) into air. This study used low-density polyethylene passive samplers to measure concentrations of PAHs in air near active (n = 3) and proposed (n = 2) NGE sites. At each site, two concentric rings of air samplers were placed around the active or proposed well pad location. Silicone wristbands were used to assess personal PAH exposures of participants (n = 19) living or working near the sampling sites. All samples were analyzed for 62 PAHs using GC-MS/MS, and point sources were estimated using the fluoranthene/pyrene isomer ratio. ∑PAH was significantly higher in air at active NGE sites (Wilcoxon rank sum test, p < 0.01). PAHs in air were also more petrogenic (petroleum-derived) at active NGE sites. This suggests that PAH mixtures at active NGE sites may have been affected by direct emissions from petroleum sources at these sites. ∑PAH was also significantly higher in wristbands from participants who had active NGE wells on their properties than from participants who did not (Wilcoxon rank sum test, p < 0.005). There was a significant positive correlation between ∑PAH in participants' wristbands and ∑PAH in air measured closest to participants' homes or workplaces (simple linear regression, p < 0.0001). These findings suggest that living or working near an active NGE well may increase personal PAH exposure. This work also supports the utility of the silicone wristband to assess personal PAH exposure.
Collapse
Affiliation(s)
- L Blair Paulik
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR 97331, United States
| | - Kevin A Hobbie
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR 97331, United States
| | - Diana Rohlman
- College of Public Health and Human Sciences, Oregon State University, Corvallis, OR 97331, United States
| | - Brian W Smith
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR 97331, United States
| | - Richard P Scott
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR 97331, United States
| | - Laurel Kincl
- College of Public Health and Human Sciences, Oregon State University, Corvallis, OR 97331, United States
| | - Erin N Haynes
- College of Medicine, Department of Environmental Health, University of Cincinnati, Cincinnati, OH 45267, United States
| | - Kim A Anderson
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR 97331, United States.
| |
Collapse
|
29
|
Matatiele P, Mochaki L, Southon B, Dabula B, Poongavanum P, Kgarebe B. Environmental and biological monitoring in the workplace: A 10-year South African retrospective analysis. AAS Open Res 2018; 1:20. [DOI: 10.12688/aasopenres.12882.1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/04/2018] [Indexed: 11/20/2022] Open
Abstract
This report is an overview of requests for biological and environmental monitoring of hazardous chemicals, submitted to the National Institute for Occupational Health, Analytical Services Laboratory for testing from the years 2005 to 2015. The report discusses the nature of tests requested and implications for workers’ health and environment, as well as potential impact of the uncertainties associated with monitoring of hazardous chemicals. This is a retrospective, descriptive, qualitative and quantitative audit of all samples received and tests performed retrieved from records of analysis by the laboratory. The study sample consisted of 44,221 samples. The report indicates that throughout the interrogation period the demand for biological monitoring was higher than that for environmental monitoring, with more requests for toxic metals than organic pollutants. Toxic metal testing was highest for mercury, followed by manganese, lead, aluminium and arsenic. The highest number of tests for organic pollutants was conducted for pesticides followed by toluene and xylene. The study has also revealed that the scope of tests requested is rather narrow and does not reflect the broad spectrum of South Africa’s industrial diversity. Having identified possible reasons for underutilization, a number of reforms that could enhance the laboratory’s performance have been addressed.
Collapse
|
30
|
Lucattini L, Poma G, Covaci A, de Boer J, Lamoree MH, Leonards PEG. A review of semi-volatile organic compounds (SVOCs) in the indoor environment: occurrence in consumer products, indoor air and dust. CHEMOSPHERE 2018; 201:466-482. [PMID: 29529574 DOI: 10.1016/j.chemosphere.2018.02.161] [Citation(s) in RCA: 188] [Impact Index Per Article: 31.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2017] [Revised: 02/24/2018] [Accepted: 02/26/2018] [Indexed: 05/19/2023]
Abstract
As many people spend a large part of their life indoors, the quality of the indoor environment is important. Data on contaminants such as flame retardants, pesticides and plasticizers are available for indoor air and dust but are scarce for consumer products such as computers, televisions, furniture, carpets, etc. This review presents information on semi-volatile organic compounds (SVOCs) in consumer products in an attempt to link the information available for chemicals in indoor air and dust with their indoor sources. A number of 256 papers were selected and divided among SVOCs found in consumer products (n = 57), indoor dust (n = 104) and air (n = 95). Concentrations of SVOCs in consumer products, indoor dust and air are reported (e.g. PFASs max: 13.9 μg/g in textiles, 5.8 μg/kg in building materials, 121 ng/g in house dust and 6.4 ng/m3 in indoor air). Most of the studies show common aims, such as human exposure and risk assessment. The main micro-environments investigated (houses, offices and schools) reflect the relevance of indoor air quality. Most of the studies show a lack of data on concentrations of chemicals in consumer goods and often only the presence of chemicals is reported. At the moment this is the largest obstacle linking chemicals in products to chemicals detected in indoor air and dust.
Collapse
Affiliation(s)
- Luisa Lucattini
- Department of Environment and Health, VU University Amsterdam, De Boelelaan 1108, Amsterdam, The Netherlands.
| | - Giulia Poma
- Toxicological Centre, Department of Pharmaceutical Sciences, University of Antwerp, Universiteitsplein 1, B-2610, Wilrijk, Belgium
| | - Adrian Covaci
- Toxicological Centre, Department of Pharmaceutical Sciences, University of Antwerp, Universiteitsplein 1, B-2610, Wilrijk, Belgium
| | - Jacob de Boer
- Department of Environment and Health, VU University Amsterdam, De Boelelaan 1108, Amsterdam, The Netherlands
| | - Marja H Lamoree
- Department of Environment and Health, VU University Amsterdam, De Boelelaan 1108, Amsterdam, The Netherlands
| | - Pim E G Leonards
- Department of Environment and Health, VU University Amsterdam, De Boelelaan 1108, Amsterdam, The Netherlands
| |
Collapse
|
31
|
Herkert NJ, Hornbuckle KC. Effects of room airflow on accurate determination of PUF-PAS sampling rates in the indoor environment. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2018; 20:757-766. [PMID: 29611590 PMCID: PMC5966328 DOI: 10.1039/c8em00082d] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Accurate and precise interpretation of concentrations from polyurethane passive samplers (PUF-PAS) is important as more studies show elevated concentrations of PCBs and other semivolatile air toxics in indoor air of schools and homes. If sufficiently reliable, these samplers may be used to identify local sources and human health risks. Here we report indoor air sampling rates (Rs) for polychlorinated biphenyl congeners (PCBs) predicted for a frequently used double-dome and a half-dome PUF-PAS design. Both our experimentally calibrated (1.10 ± 0.23 m3 d-1) and modeled (1.08 ± 0.04 m3 d-1) Rs for the double-dome samplers compare well with literature reports for similar rooms. We determined that variability of wind speeds throughout the room significantly (P < 0.001) effected uptake rates. We examined this effect using computational fluid dynamics modeling and 3-D sonic anemometer measurements and found the airflow dynamics to have a significant but small impact on the precision of calculated airborne concentrations. The PUF-PAS concentration measurements were within 27% and 10% of the active sampling concentration measurements for the double-dome and half-dome designs, respectively. While the half-dome samplers produced more consistent concentration measurements, we find both designs to perform well indoors.
Collapse
Affiliation(s)
- Nicholas J Herkert
- Department of Civil & Environmental Engineering, IIHR-Hydroscience and Engineering, The University of Iowa, 4105 SC, Iowa City, IA 52242, USA.
| | | |
Collapse
|
32
|
Dixon HM, Scott RP, Holmes D, Calero L, Kincl LD, Waters KM, Camann DE, Calafat AM, Herbstman JB, Anderson KA. Silicone wristbands compared with traditional polycyclic aromatic hydrocarbon exposure assessment methods. Anal Bioanal Chem 2018; 410:3059-3071. [PMID: 29607448 PMCID: PMC5910488 DOI: 10.1007/s00216-018-0992-z] [Citation(s) in RCA: 72] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 01/31/2018] [Accepted: 03/01/2018] [Indexed: 12/16/2022]
Abstract
Currently there is a lack of inexpensive, easy-to-use technology to evaluate human exposure to environmental chemicals, including polycyclic aromatic hydrocarbons (PAHs). This is the first study in which silicone wristbands were deployed alongside two traditional personal PAH exposure assessment methods: active air monitoring with samplers (i.e., polyurethane foam (PUF) and filter) housed in backpacks, and biological sampling with urine. We demonstrate that wristbands worn for 48 h in a non-occupational setting recover semivolatile PAHs, and we compare levels of PAHs in wristbands to PAHs in PUFs-filters and to hydroxy-PAH (OH-PAH) biomarkers in urine. We deployed all samplers simultaneously for 48 h on 22 pregnant women in an established urban birth cohort. Each woman provided one spot urine sample at the end of the 48-h period. Wristbands recovered PAHs with similar detection frequencies to PUFs-filters. Of the 62 PAHs tested for in the 22 wristbands, 51 PAHs were detected in at least one wristband. In this cohort of pregnant women, we found more significant correlations between OH-PAHs and PAHs in wristbands than between OH-PAHs and PAHs in PUFs-filters. Only two comparisons between PAHs in PUFs-filters and OH-PAHs correlated significantly (rs = 0.53 and p = 0.01; rs = 0.44 and p = 0.04), whereas six comparisons between PAHs in wristbands and OH-PAHs correlated significantly (rs = 0.44 to 0.76 and p = 0.04 to <0.0001). These results support the utility of wristbands as a biologically relevant exposure assessment tool which can be easily integrated into environmental health studies. PAHs detected in samples collected from urban pregnant women ![]()
Collapse
Affiliation(s)
- Holly M Dixon
- Food Safety and Environmental Stewardship Program, Environmental and Molecular Toxicology, Oregon State University, 1007 Agricultural and Life Sciences Building, Corvallis, OR, 97331, USA
| | - Richard P Scott
- Food Safety and Environmental Stewardship Program, Environmental and Molecular Toxicology, Oregon State University, 1007 Agricultural and Life Sciences Building, Corvallis, OR, 97331, USA
| | - Darrell Holmes
- Columbia Center for Children's Environmental Health, Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, 722 West 168th Street, New York, NY, 10032, USA
| | - Lehyla Calero
- Columbia Center for Children's Environmental Health, Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, 722 West 168th Street, New York, NY, 10032, USA
| | - Laurel D Kincl
- College of Public Health and Human Sciences, Department of Environmental and Occupational Health, Oregon State University, 160 SW 26th St, Corvallis, OR, 97331, USA
| | - Katrina M Waters
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, WA, 99352, USA
| | - David E Camann
- Chemistry and Chemical Engineering Division, Southwest Research Institute, P.O. Drawer 28510, San Antonio, TX, 78228-0510, USA
| | - Antonia M Calafat
- Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, 1600 Clifton Road, Atlanta, GA, 30333, USA
| | - Julie B Herbstman
- Columbia Center for Children's Environmental Health, Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, 722 West 168th Street, New York, NY, 10032, USA
| | - Kim A Anderson
- Food Safety and Environmental Stewardship Program, Environmental and Molecular Toxicology, Oregon State University, 1007 Agricultural and Life Sciences Building, Corvallis, OR, 97331, USA.
| |
Collapse
|
33
|
Strandberg B, Julander A, Sjöström M, Lewné M, Koca Akdeva H, Bigert C. Evaluation of polyurethane foam passive air sampler (PUF) as a tool for occupational PAH measurements. CHEMOSPHERE 2018; 190:35-42. [PMID: 28985535 DOI: 10.1016/j.chemosphere.2017.09.106] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Revised: 09/21/2017] [Accepted: 09/22/2017] [Indexed: 06/07/2023]
Abstract
Routine monitoring of workplace exposure to polycyclic aromatic hydrocarbons (PAHs) is performed mainly via active sampling. However, active samplers have several drawbacks and, in some cases, may even be unusable. Polyurethane foam (PUF) as personal passive air samplers constitute good alternatives for PAH monitoring in occupational air (8 h). However, PUFs must be further tested to reliably yield detectable levels of PAHs in short exposure times (1-3 h) and under extreme occupational conditions. Therefore, we compared the personal exposure monitoring performance of a passive PUF sampler with that of an active air sampler and determined the corresponding uptake rates (Rs). These rates were then used to estimate the occupational exposure of firefighters and police forensic specialists to 32 PAHs. The work environments studied were heavily contaminated by PAHs with (for example) benzo(a)pyrene ranging from 0.2 to 56 ng m-3, as measured via active sampling. We show that, even after short exposure times, PUF can reliably accumulate both gaseous and particle-bound PAHs. The Rs-values are almost independent of variables such as the concentration and the wind speed. Therefore, by using the Rs-values (2.0-20 m3 day-1), the air concentrations can be estimated within a factor of two for gaseous PAHs and a factor of 10 for particulate PAHs. With very short sampling times (1 h), our method can serve as a (i) simple and user-friendly semi-quantitative screening tool for estimating and tracking point sources of PAH in micro-environments and (ii) complement to the traditional active pumping methods.
Collapse
Affiliation(s)
- Bo Strandberg
- Section of Occupational and Environmental Medicine, Institute of Medicine, Sahlgrenska Academy at the University of Gothenburg, Gothenburg, Sweden; Division of Occupational and Environmental Medicine, Lund University, Lund, Sweden.
| | - Anneli Julander
- Unit of Work Environment Toxicology, Institute of Environmental Medicine, Karolinska Institutet, Stockholm, Sweden
| | - Mattias Sjöström
- Unit of Occupational Medicine, Institute of Environmental Medicine, Karolinska Institutet, Stockholm, Sweden; Centre for Occupational and Environmental Medicine, Stockholm County Council, Stockholm, Sweden
| | - Marie Lewné
- Unit of Occupational Medicine, Institute of Environmental Medicine, Karolinska Institutet, Stockholm, Sweden; Centre for Occupational and Environmental Medicine, Stockholm County Council, Stockholm, Sweden
| | - Hatice Koca Akdeva
- Section of Occupational and Environmental Medicine, Institute of Medicine, Sahlgrenska Academy at the University of Gothenburg, Gothenburg, Sweden
| | - Carolina Bigert
- Unit of Occupational Medicine, Institute of Environmental Medicine, Karolinska Institutet, Stockholm, Sweden; Centre for Occupational and Environmental Medicine, Stockholm County Council, Stockholm, Sweden
| |
Collapse
|
34
|
Bergmann AJ, North PE, Vasquez L, Bello H, del Carmen Gastañaga Ruiz M, Anderson KA. Multi-class chemical exposure in rural Peru using silicone wristbands. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2017; 27:560-568. [PMID: 28745304 PMCID: PMC5658680 DOI: 10.1038/jes.2017.12] [Citation(s) in RCA: 58] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2016] [Accepted: 06/02/2017] [Indexed: 05/18/2023]
Abstract
Exposure monitoring with personal silicone wristband samplers was demonstrated in Peru in four agriculture and urban communities where logistic and practical constraints hinder use of more traditional approaches. Wristbands and associated methods enabled quantitation of 63 pesticides and screening for 1397 chemicals including environmental contaminants and personal care products. Sixty-eight wristbands were worn for approximately one month by volunteers from four communities of Alto Mayo, Peru. We identified 106 chemicals from eight chemical classes among all wristbands. Agricultural communities were characterized by pesticides and PAHs, while the urban communities had more personal care products present. Multiple linear regressions explained up to 40% of variance in wristbands from chlorpyrifos, cypermethrin, and DDT and its metabolites (DDx) (r2=0.39, 0.30, 0.40, respectively). All three pesticides were significantly different between communities, and cypermethrin and DDx were associated with participant age. The calculated relative age of DDT suggested some communities had more recent exposure than others. This work aids health research in the Alto Mayo and beyond by identifying typical mixtures and potential sources of exposure to organic chemicals in the personal environment. Silicone wristband sampling with chemical screening is a candidate for widespread use in exposure monitoring in remote areas.
Collapse
Affiliation(s)
- Alan J Bergmann
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, Oregon, USA
| | - Paula E North
- Department of Pathology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Luis Vasquez
- Yantaló Peru Foundation, Yantaló, Moyobamba, Peru
| | - Hernan Bello
- Department of Pathology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | | | - Kim A Anderson
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, Oregon, USA
- Department of Environmental and Molecular Toxicology, Oregon State University College of Agricultural Sciences, 1007 Agricultural and Life Sciences Building, Corvallis, OR 97331, USA. Tel.: +541 737 8501. Fax: +541 737 0497. E-mail:
| |
Collapse
|
35
|
Anderson KA, Points GL, Donald CE, Dixon HM, Scott RP, Wilson G, Tidwell LG, Hoffman PD, Herbstman JB, O'Connell SG. Preparation and performance features of wristband samplers and considerations for chemical exposure assessment. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2017; 27:551-559. [PMID: 28745305 PMCID: PMC5658681 DOI: 10.1038/jes.2017.9] [Citation(s) in RCA: 87] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2017] [Accepted: 05/19/2017] [Indexed: 05/21/2023]
Abstract
Wristbands are increasingly used for assessing personal chemical exposures. Unlike some exposure assessment tools, guidelines for wristbands, such as preparation, applicable chemicals, and transport and storage logistics, are lacking. We tested the wristband's capacity to capture and retain 148 chemicals including polychlorinated biphenyls (PCBs), pesticides, flame retardants, polycyclic aromatic hydrocarbons (PAHs), and volatile organic chemicals (VOCs). The chemicals span a wide range of physical-chemical properties, with log octanol-air partitioning coefficients from 2.1 to 13.7. All chemicals were quantitatively and precisely recovered from initial exposures, averaging 102% recovery with relative SD ≤21%. In simulated transport conditions at +30 °C, SVOCs were stable up to 1 month (average: 104%) and VOC levels were unchanged (average: 99%) for 7 days. During long-term storage at -20 °C up to 3 (VOCs) or 6 months (SVOCs), all chemical levels were stable from chemical degradation or diffusional losses, averaging 110%. Applying a paired wristband/active sampler study with human participants, the first estimates of wristband-air partitioning coefficients for PAHs are presented to aid in environmental air concentration estimates. Extrapolation of these stability results to other chemicals within the same physical-chemical parameters is expected to yield similar results. As we better define wristband characteristics, wristbands can be better integrated in exposure science and epidemiological studies.
Collapse
Affiliation(s)
- Kim A Anderson
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, Oregon, USA
- Department of Environmental and Molecular Toxicology, Oregon State University, 1007 Agricultural and Life Sciences Building, Corvallis, OR 97331, USA. Tel.: +1 541 737 8501. Fax: +1 541 737 0497. E-mail:
| | - Gary L Points
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, Oregon, USA
| | - Carey E Donald
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, Oregon, USA
| | - Holly M Dixon
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, Oregon, USA
| | - Richard P Scott
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, Oregon, USA
| | - Glenn Wilson
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, Oregon, USA
| | - Lane G Tidwell
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, Oregon, USA
| | - Peter D Hoffman
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, Oregon, USA
| | - Julie B Herbstman
- Columbia Center for Children’s Environmental Health, Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York, USA
| | - Steven G O'Connell
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, Oregon, USA
| |
Collapse
|
36
|
Hsieh HC, Kim H. A miniature closed-loop gas chromatography system. LAB ON A CHIP 2016; 16:1002-1012. [PMID: 26911622 DOI: 10.1039/c5lc01553g] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This paper reports the characterization of a miniaturized circulatory column system that is capable of magnifying the effective column length by forming a circulatory loop with chip-scale columns, thus ultimately achieving high-efficiency target separation. The circulatory column system is composed of a tandem of 25 cm microcolumns and six valves for fluidic flow control in order to enable chromatographic separation in circulatory motions while requiring only 5.5 kPa of pressure, which current micropumps are currently capable of supplying. The developed column system (1) successfully demonstrated 16 times elongation of a virtual column length up to 800 cm by only utilizing two 25 cm microcolumns, which is the longest column length reported by any MEMS-scale functioning GC column, (2) achieved a high theoretical plate number of 68,696 with pentane circulating after 15.5 circulatory cycles, which corresponds to the plate number per length-pressure of 1611 plate m(-1) kPa(-1), the highest record reported yet, and (3) demonstrated successful separation of target molecules during circulation by utilizing a pentane/hexane mixture, resulting in magnification of the two corresponding peaks via circulation.
Collapse
Affiliation(s)
- Hao-Chieh Hsieh
- Department of Electrical & Computer Engineering, University of Utah, SMBB-3100, 36 South Wasatch Drive, Salt Lake City, UT 84112, USA.
| | | |
Collapse
|
37
|
Han W, Fan T, Xu B, Feng J, Zhang G, Wu M, Yu Y, Fu J. Passive sampling of polybrominated diphenyl ethers in indoor and outdoor air in Shanghai, China: seasonal variations, sources, and inhalation exposure. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2016; 23:5771-5781. [PMID: 26585455 DOI: 10.1007/s11356-015-5792-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2015] [Accepted: 11/10/2015] [Indexed: 06/05/2023]
Abstract
Ninety-seven seasonal, passive indoor and outdoor air samples were collected in Shanghai to study polybrominated diphenyl ethers (ΣPBDEs, 16 congeners including BDE-209), their concentrations, composition profiles, seasonal variations, influencing factors, emission sources, and human inhalation exposure. In summer, median indoor concentrations of Σ 15 PBDEs (excluding BDE-209) were 82 pg m(-3) in offices and 30 pg m(-3) in homes, ∼3 times the winter concentrations. The average summer concentration of 130 pg m(-3) BDE-209 in homes was higher than that in offices (which was 90 pg m(-3)); in winter, home and office concentrations were similar (46 and 47 pg m(-3), respectively). For outdoor air, the median concentration of Σ 15 PBDEs in summer (12 pg m(-3)) was twice the winter concentration (6 pg m(-3)), while the summer median concentration of BDE-209 (398 pg m(-3)) was half the winter concentration (794 pg m(-3)). Higher concentrations of Σ 15 PBDEs indoors compared with outdoors showed that the lower brominated BDEs found were mainly from indoor sources. Meanwhile, the much lower indoor concentration of BDE-209 compared with the outdoors showed that BDE-209 came mainly from outdoor sources. The data set also indicated that electric/electronic appliances were the main sources of indoor ΣPBDEs, and old appliances emitted more lower brominated BDEs, while industrial emissions should be the main source of the outdoor BDE-209. Median daily human exposures to Σ 15 PBDEs and BDE-209 through inhalation were estimated to be 0.23 and 1.73 ng day(-1) in winter and 0.65 and 2.28 ng day(-1) in summer for adults. The human inhalation exposure to ΣPBDEs (3.44 ng day(-1) for adults and 1.33 ng day(-1) for toddlers) was comparable to that from eating contaminated fish for both toddlers and adults in Shanghai.
Collapse
Affiliation(s)
- Wenliang Han
- Institute of Environmental and Resources Technology, Department of Environmental Science and Engineering, College of Chemical Engineering, Huaqiao University, Xiamen, 361021, China
| | - Tao Fan
- Institute of Environmental and Resources Technology, Department of Environmental Science and Engineering, College of Chemical Engineering, Huaqiao University, Xiamen, 361021, China
| | - Binhua Xu
- Institute of Environmental Pollution and Health, Shanghai University, Shanghai, 200444, China
| | - Jialiang Feng
- Institute of Environmental Pollution and Health, Shanghai University, Shanghai, 200444, China.
| | - Gan Zhang
- Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, 510640, China
| | - Minghong Wu
- Institute of Environmental Pollution and Health, Shanghai University, Shanghai, 200444, China
| | - Yingxin Yu
- Institute of Environmental Pollution and Health, Shanghai University, Shanghai, 200444, China
| | - Jiamo Fu
- Institute of Environmental Pollution and Health, Shanghai University, Shanghai, 200444, China
| |
Collapse
|
38
|
Melymuk L, Bohlin P, Sáňka O, Pozo K, Klánová J. Current challenges in air sampling of semivolatile organic contaminants: sampling artifacts and their influence on data comparability. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:14077-91. [PMID: 25329599 DOI: 10.1021/es502164r] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
With current science and policy needs, more attention is being given to expanding and improving air sampling of semivolatile organic contaminants (SVOCs). However, a wide range of techniques and configurations are currently used (active and passive samplers, different deployment times, different sorbents, etc.) and as the SVOC community looks to assess air measurements on a global scale, questions of comparability arise. We review current air sampling techniques, with a focus on sampling artifacts that can lead to uncertainties or biases in reported concentrations, in particular breakthrough, degradation, meteorological influences, and assumptions regarding passive sampling. From this assessment, we estimate the bias introduced for SVOC concentrations from all factors. Due to the effects of breakthrough, degradation, particle fractions and sampler uptake periods, some current passive and active sampler configurations may underestimate certain SVOCs by 30-95%. We then recommend future study design, appropriateness of sampler types for different study goals, and finally, how the SVOC community should move forward in both research and monitoring to best achieve comparability and consistency in air measurements.
Collapse
Affiliation(s)
- Lisa Melymuk
- Research Centre for Toxic Compounds in the Environment (RECETOX), Faculty of Science, Masaryk University , Kamenice 5/753, Pavilon A29, Brno 62500, Czech Republic
| | | | | | | | | |
Collapse
|
39
|
Chaemfa C, Xu Y, Li J, Chakraborty P, Hussain Syed J, Naseem Malik R, Wang Y, Tian C, Zhang G, Jones KC. Screening of atmospheric short- and medium-chain chlorinated paraffins in India and Pakistan using polyurethane foam based passive air sampler. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:4799-808. [PMID: 24666432 DOI: 10.1021/es405186m] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Production and use of chlorinated paraffins (CPs) have been increasing in India. Distribution of CPs in the area and vicinity have become a great concern due to their persistency and toxicity. Polyurethane foam based passive air samplers (PUF-PAS) was deployed in order to screen the presence of short- and medium- chain chlorinated paraffins (SCCPs and MCCPs) in the outdoor atmosphere at many sites in India (in winter 2006) and Pakistan (in winter 2011). Concentrations of SCCPs and MCCPs ranged from not detected (ND) to 47.4 and 0 to 38.2 ng m(-3) with means of 8.11 and 4.83 ng m(-3), respectively. Indian concentrations showed higher average levels of both SCCPs and MCCPs India (10.2 ng m(-3) and 3.62 ng m(-3)than the samples from Pakistan (5.13 ng m(-3) and 4.21 ng m(-3)). Relative abundance patterns of carbon number are C10 > C11 > C12 ∼ C13 for SCCPs and C14 > C15 > C16 C17 for MCCP with similarity to the profiles of samples from China, the biggest CPs producer in the world. Principal Component Analysis suggested that detected SCCPs and MCCPs in this study originated from the same emission source.
Collapse
Affiliation(s)
- Chakra Chaemfa
- State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences , Guangzhou, 510640, China
| | | | | | | | | | | | | | | | | | | |
Collapse
|
40
|
O’Connell S, Kincl L, Anderson KA. Silicone wristbands as personal passive samplers. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:3327-35. [PMID: 24548134 PMCID: PMC3962070 DOI: 10.1021/es405022f] [Citation(s) in RCA: 165] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2013] [Revised: 02/13/2014] [Accepted: 02/18/2014] [Indexed: 05/18/2023]
Abstract
Active-sampling approaches are commonly used for personal monitoring, but are limited by energy usage and data that may not represent an individual's exposure or bioavailable concentrations. Current passive techniques often involve extensive preparation, or are developed for only a small number of targeted compounds. In this work, we present a novel application for measuring bioavailable exposure with silicone wristbands as personal passive samplers. Laboratory methodology affecting precleaning, infusion, and extraction were developed from commercially available silicone, and chromatographic background interference was reduced after solvent cleanup with good extraction efficiency (>96%). After finalizing laboratory methods, 49 compounds were sequestered during an ambient deployment which encompassed a diverse set of compounds including polycyclic aromatic hydrocarbons (PAHs), consumer products, personal care products, pesticides, phthalates, and other industrial compounds ranging in log K(ow) from -0.07 (caffeine) to 9.49 (tris(2-ethylhexyl) phosphate). In two hot asphalt occupational settings, silicone personal samplers sequestered 25 PAHs during 8- and 40-h exposures, as well as 2 oxygenated-PAHs (benzofluorenone and fluorenone) suggesting temporal sensitivity over a single work day or week (p < 0.05, power =0.85). Additionally, the amount of PAH sequestered differed between worksites (p < 0.05, power = 0.99), suggesting spatial sensitivity using this novel application.
Collapse
Affiliation(s)
- Steven
G. O’Connell
- Department of
Environmental and Molecular Toxicology and College of Public Health and Human
Sciences, Oregon State University, Corvallis, Oregon 97331, United States
| | - Laurel
D. Kincl
- Department of
Environmental and Molecular Toxicology and College of Public Health and Human
Sciences, Oregon State University, Corvallis, Oregon 97331, United States
| | - Kim A. Anderson
- Department of
Environmental and Molecular Toxicology and College of Public Health and Human
Sciences, Oregon State University, Corvallis, Oregon 97331, United States
| |
Collapse
|
41
|
Novel method for determining DDT in vapour and particulate phases within contaminated indoor air in a malaria area of South Africa. Anal Chim Acta 2012; 730:112-9. [DOI: 10.1016/j.aca.2012.02.054] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2011] [Revised: 02/15/2012] [Accepted: 02/28/2012] [Indexed: 11/21/2022]
|
42
|
|
43
|
Hursthouse A, Kowalczyk G. Transport and dynamics of toxic pollutants in the natural environment and their effect on human health: research gaps and challenge. ENVIRONMENTAL GEOCHEMISTRY AND HEALTH 2009; 31:165-187. [PMID: 19002593 DOI: 10.1007/s10653-008-9213-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2008] [Revised: 08/19/2008] [Accepted: 08/22/2008] [Indexed: 05/27/2023]
Abstract
The source-pathway-receptor (SPR) approach to human exposure and risk assessment contains considerable uncertainty when using the refined modelling approaches to pollutant transport and dispersal, not least in how compounds of concern might be prioritized, proxy or indicator substances identified and the basic environmental and toxicological data collected. The impact of external environmental variables, urban systems and lifestyle is still poorly understood. This determines exposure of individuals and there are a number of methods being developed to provide more reliable spatial assessments. Within the human body, the dynamics of pollutants and effects on target organs from diffuse, transient sources of exposure sets ambitious challenges for traditional risk assessment approaches. Considerable potential exists in the application of, e.g. physiologically based pharmacokinetic (PBPK) models. The reduction in uncertainties associated with the effects of contaminants on humans, transport and dynamics influencing exposure, implications of adult versus child exposure and lifestyle and the development of realistic toxicological and exposure data are all highlighted as urgent research needs. The potential to integrate environmental with toxicological models provides the next phase of research opportunity and should be used to drive empirical and model assessments.
Collapse
Affiliation(s)
- Andrew Hursthouse
- School of Engineering & Science, University of the West of Scotland, Paisley Campus, Paisley PA12BE, UK.
| | | |
Collapse
|
44
|
Wang J, Tuduri L, Mercury M, Millet M, Briand O, Montury M. Sampling atmospheric pesticides with SPME: Laboratory developments and field study. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2009; 157:365-370. [PMID: 19010574 DOI: 10.1016/j.envpol.2008.10.006] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2008] [Revised: 09/23/2008] [Accepted: 10/04/2008] [Indexed: 05/27/2023]
Abstract
To estimate the atmospheric exposure of the greenhouse workers to pesticides, solid phase microextraction (SPME) was used under non-equilibrium conditions. Using Fick's law of diffusion, the concentrations of pesticides in the greenhouse can be calculated using pre-determined sampling rates (SRs). Thus the sampling rates (SRs) of two modes of SPME in the lab and in the field were determined and compared. The SRs for six pesticides in the lab were 20.4-48.3 mL min(-1) for the exposed fiber and 0.166-0.929 mL min(-1) for the retracted fiber. In field sampling, two pesticides, dichlorvos and cyprodinil were detected with exposed SPME. SR with exposed SPME for dichlorvos in the field (32.4 mL min(-1)) was consistent with that in the lab (34.5 mL min(-1)). SR for dichlorvos in the field (32.4 mL min(-1)) was consistent with that in the lab (34.5 mL min(-1)). The trends of temporal concentration and the inhalation exposure were also obtained.
Collapse
Affiliation(s)
- Junxia Wang
- EPCA-Institut des Sciences Moléculaires, UMR 5255 CNRS-Université Bordeaux 1,ISM, Site universitaire, 24019 Périgueux Cedex, France
| | | | | | | | | | | |
Collapse
|
45
|
Chaemfa C, Barber JL, Moeckel C, Gocht T, Harner T, Holoubek I, Klanova J, Jones KC. Field calibration of polyurethane foam disk passive air samplers for PBDEs. ACTA ACUST UNITED AC 2009; 11:1859-65. [DOI: 10.1039/b903152a] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
46
|
Garcia-Jares C, Regueiro J, Barro R, Dagnac T, Llompart M. Analysis of industrial contaminants in indoor air. Part 2. Emergent contaminants and pesticides. J Chromatogr A 2009; 1216:567-97. [DOI: 10.1016/j.chroma.2008.10.020] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2008] [Revised: 09/11/2008] [Accepted: 10/08/2008] [Indexed: 11/25/2022]
|
47
|
Analysis of industrial contaminants in indoor air: Part 1. Volatile organic compounds, carbonyl compounds, polycyclic aromatic hydrocarbons and polychlorinated biphenyls. J Chromatogr A 2009; 1216:540-66. [DOI: 10.1016/j.chroma.2008.10.117] [Citation(s) in RCA: 140] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2008] [Revised: 10/27/2008] [Accepted: 10/31/2008] [Indexed: 11/20/2022]
|
48
|
Chaemfa C, Barber JL, Gocht T, Harner T, Holoubek I, Klanova J, Jones KC. Field calibration of polyurethane foam (PUF) disk passive air samplers for PCBs and OC pesticides. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2008; 156:1290-1297. [PMID: 18474408 DOI: 10.1016/j.envpol.2008.03.016] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2007] [Revised: 03/05/2008] [Accepted: 03/20/2008] [Indexed: 05/26/2023]
Abstract
Different passive air sampler (PAS) strategies have been developed for sampling in remote areas and for cost-effective simultaneous spatial mapping of POPs (persistent organic pollutants) over differing geographical scales. The polyurethane foam (PUF) disk-based PAS is probably the most widely used. In a PUF-based PAS, the PUF disk is generally mounted inside two stainless steel bowls to buffer the air flow to the disk and to shield it from precipitation and light. The field study described in this manuscript was conducted to: compare performance of 3 different designs of sampler; to further calibrate the sampler against the conventional active sampler; to derive more information on field-based uptake rates and equilibrium times of the samplers. Samplers were also deployed at different locations across the field site, and at different heights up a meteorological tower, to investigate the possible influence of sampler location. Samplers deployed <5m above ground, and not directly sheltered from the wind gave similar uptake rates. Small differences in dimensions between the 3 designs of passive sampler chamber had no discernable effect on accumulation rates, allowing comparison with previously published data.
Collapse
Affiliation(s)
- Chakra Chaemfa
- Centre for Chemicals Management and Environmental Science Department, Lancaster Environment Centre, Lancaster University, Lancaster LA14YQ, UK
| | | | | | | | | | | | | |
Collapse
|
49
|
Gouin T, Wania F, Ruepert C, Castillo LE. Field testing passive air samplers for current use pesticides in a tropical environment. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2008; 42:6625-6630. [PMID: 18800540 DOI: 10.1021/es8008425] [Citation(s) in RCA: 65] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Air was sampled for one year in the central valley of Costa Rica using an active high-volume sampler as well as passive samplers (PAS) based on polyurethane foam (PUF) disks and XAD-resin filled mesh cylinders. Extracts were analyzed for pesticides that are either banned or currently used in Costa Rican agriculture. Sampling rates for PUF-based passive air samplers, determined from the loss of depuration compounds spiked on the disks prior to deployment averaged 5.9 +/- 0.9 m3 x d(-1) and were higher during the windier dry season than during the rainy season. Sampling rates for the XAD-based passive sampler were determined from the slopes of linear relationships that were observed between the amount of pesticide sequestered in the resin and the length of deployment, which varied from 4 months to 1 year. Those sampling rates increased with decreasing molecular size of a pesticide, and their average of 2.1 +/- 1.5 m3 x d(-1) is higher than rates previously reported for temperate and polar sampling sites. Even though the trends of the sampling rate with molecular size and temperature are consistent with the hypothesis that molecular diffusion controls uptake in passive samplers, the trends are much more pronounced than a direct proportionality between sampling rate and molecular diffusivity would suggest. Air concentrations derived by the three sampling methods are within a factor of 2 of each other, suggesting that properly calibrated PAS can be effective tools for monitoring levels of pesticides in the tropical atmosphere. In particular, HiVol samplers, PUF-disk samplers, and XAD-based passive samplers are suitable for obtaining information on air concentration variability on the time scale of days, seasons and years, respectively. This study represents the first calibration study for the uptake of current use pesticides by passive air samplers.
Collapse
Affiliation(s)
- Todd Gouin
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario, Canada M1C 1A4.
| | | | | | | |
Collapse
|