1
|
Prochilo G, Pfeffer A, Du S, Kaneko N, Liebeskind DS, Hinman JD. Recent Translational Research Models of Intracranial Atherosclerotic Disease. Stroke 2024; 55:1707-1719. [PMID: 38738375 DOI: 10.1161/strokeaha.124.044520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2024]
Abstract
Intracranial atherosclerotic disease (ICAD) is a leading cause of ischemic stroke worldwide. However, research on the pathophysiology of ICAD is scarce due to the relative inaccessibility of histology samples and the lack of comprehensive experimental models. As a result, much of the current understanding of ICAD relies on research on extracranial atherosclerosis. This approach is problematic as intracranial and extracranial arteries are anatomically, structurally, physiologically, and metabolically distinct, indicating that intracranial and extracranial atherosclerosis likely develop through different biologic pathways. The current standard of care for ICAD treatment relies predominantly on therapeutics developed to treat extracranial atherosclerosis and is insufficient given the alarmingly high risk of stroke. To provide a definitive treatment for the disease, a deeper understanding of the pathophysiology underlying ICAD is specifically required. True mechanistic understanding of disease pathogenesis is only possible using robust experimental models. In this review, we aim to identify the advantages and limitations of the existing in vivo and in vitro models of ICAD and basic atherosclerotic processes, which may be used to inform better models of ICAD in the future and drive new therapeutic strategies to reduce stroke risk.
Collapse
Affiliation(s)
- Grace Prochilo
- Departments of Neurology (G.P., A.P., S.D., D.S.L., J.D.H.), David Geffen School of Medicine, University of California, Los Angeles
| | - Alissa Pfeffer
- Departments of Neurology (G.P., A.P., S.D., D.S.L., J.D.H.), David Geffen School of Medicine, University of California, Los Angeles
| | - Stephanie Du
- Departments of Neurology (G.P., A.P., S.D., D.S.L., J.D.H.), David Geffen School of Medicine, University of California, Los Angeles
| | - Naoki Kaneko
- Radiology (N.K.), David Geffen School of Medicine, University of California, Los Angeles
| | - David S Liebeskind
- Departments of Neurology (G.P., A.P., S.D., D.S.L., J.D.H.), David Geffen School of Medicine, University of California, Los Angeles
| | - Jason D Hinman
- Departments of Neurology (G.P., A.P., S.D., D.S.L., J.D.H.), David Geffen School of Medicine, University of California, Los Angeles
- Department of Neurology, Department of Veterans Affairs Medical Center, Los Angeles, CA (J.D.H.)
| |
Collapse
|
2
|
Goh T, Gao L, Singh J, Totaro R, Carey R, Yang K, Cartwright B, Dennis M, Ju LA, Waterhouse A. Platelet Adhesion and Activation in an ECMO Thrombosis-on-a-Chip Model. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024:e2401524. [PMID: 38757670 DOI: 10.1002/advs.202401524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2024] [Revised: 04/03/2024] [Indexed: 05/18/2024]
Abstract
Use of extracorporeal membrane oxygenation (ECMO) for cardiorespiratory failure remains complicated by blood clot formation (thrombosis), triggered by biomaterial surfaces and flow conditions. Thrombosis may result in ECMO circuit changes, cause red blood cell hemolysis, and thromboembolic events. Medical device thrombosis is potentiated by the interplay between biomaterial properties, hemodynamic flow conditions and patient pathology, however, the contribution and importance of these factors are poorly understood because many in vitro models lack the capability to customize material and flow conditions to investigate thrombosis under clinically relevant medical device conditions. Therefore, an ECMO thrombosis-on-a-chip model is developed that enables highly customizable biomaterial and flow combinations to evaluate ECMO thrombosis in real-time with low blood volume. It is observed that low flow rates, decelerating conditions, and flow stasis significantly increased platelet adhesion, correlating with clinical thrombus formation. For the first time, it is found that tubing material, polyvinyl chloride, caused increased platelet P-selectin activation compared to connector material, polycarbonate. This ECMO thrombosis-on-a-chip model can be used to guide ECMO operation, inform medical device design, investigate embolism, occlusion and platelet activation mechanisms, and develop anti-thrombotic biomaterials to ultimately reduce medical device thrombosis, anti-thrombotic drug use and therefore bleeding complications, leading to safer blood-contacting medical devices.
Collapse
Affiliation(s)
- Tiffany Goh
- School of Medical Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, 2006, Australia
- Heart Research Institute, Newtown, NSW, 2042, Australia
- Charles Perkins Centre, The University of Sydney, Sydney, NSW, 2006, Australia
- The University of Sydney Nano Institute, The University of Sydney, Sydney, NSW, 2006, Australia
| | - Lingzi Gao
- School of Medical Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, 2006, Australia
- Heart Research Institute, Newtown, NSW, 2042, Australia
- Charles Perkins Centre, The University of Sydney, Sydney, NSW, 2006, Australia
- The University of Sydney Nano Institute, The University of Sydney, Sydney, NSW, 2006, Australia
| | - Jasneil Singh
- School of Medical Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, 2006, Australia
- Heart Research Institute, Newtown, NSW, 2042, Australia
- Charles Perkins Centre, The University of Sydney, Sydney, NSW, 2006, Australia
- The University of Sydney Nano Institute, The University of Sydney, Sydney, NSW, 2006, Australia
| | - Richard Totaro
- Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, 2006, Australia
- Intensive Care Department, Royal Prince Alfred Hospital, Missenden Road, Camperdown, Sydney, NSW, 2050, Australia
| | - Ruaidhri Carey
- Intensive Care Department, Royal Prince Alfred Hospital, Missenden Road, Camperdown, Sydney, NSW, 2050, Australia
| | - Kevin Yang
- Intensive Care Department, Royal Prince Alfred Hospital, Missenden Road, Camperdown, Sydney, NSW, 2050, Australia
| | - Bruce Cartwright
- Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, 2006, Australia
- Anaesthetics Department, Royal Prince Alfred Hospital, Camperdown, Sydney, NSW, 2050, Australia
| | - Mark Dennis
- Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, 2006, Australia
- Cardiology Department, Royal Prince Alfred Hospital, Missenden Road, Camperdown, Sydney, NSW, 2050, Australia
| | - Lining Arnold Ju
- Heart Research Institute, Newtown, NSW, 2042, Australia
- Charles Perkins Centre, The University of Sydney, Sydney, NSW, 2006, Australia
- The University of Sydney Nano Institute, The University of Sydney, Sydney, NSW, 2006, Australia
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Darlington, NSW, 2008, Australia
| | - Anna Waterhouse
- School of Medical Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, 2006, Australia
- Charles Perkins Centre, The University of Sydney, Sydney, NSW, 2006, Australia
- The University of Sydney Nano Institute, The University of Sydney, Sydney, NSW, 2006, Australia
| |
Collapse
|
3
|
Yu Z, Chen Y, Li J, Chen C, Lu H, Chen S, Zhang T, Guo T, Zhu Y, Jin J, Yan S, Chen H. A tempo-spatial controllable microfluidic shear-stress generator for in-vitro mimicking of the thrombus. J Nanobiotechnology 2024; 22:187. [PMID: 38632623 PMCID: PMC11022418 DOI: 10.1186/s12951-024-02334-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 02/09/2024] [Indexed: 04/19/2024] Open
Abstract
Pathological conditions linked to shear stress have been identified in hematological diseases, cardiovascular diseases, and cancer. These conditions often exhibit significantly elevated shear stress levels, surpassing 1000 dyn/cm2 in severely stenotic arteries. Heightened shear stress can induce mechanical harm to endothelial cells, potentially leading to bleeding and fatal consequences. However, current technology still grapples with limitations, including inadequate flexibility in simulating bodily shear stress environments, limited range of shear stress generation, and spatial and temporal adaptability. Consequently, a comprehensive understanding of the mechanisms underlying the impact of shear stress on physiological and pathological conditions, like thrombosis, remains inadequate. To address these limitations, this study presents a microfluidic-based shear stress generation chip as a proposed solution. The chip achieves a substantial 929-fold variation in shear stress solely by adjusting the degree of constriction in branch channels after PDMS fabrication. Experiments demonstrated that a rapid increase in shear stress up to 1000 dyn/cm2 significantly detached 88.2% cells from the substrate. Long-term exposure (24 h) to shear stress levels below 8.3 dyn/cm2 did not significantly impact cell growth. Furthermore, cells exposed to shear stress levels equal to or greater than 8.3 dyn/cm2 exhibited significant alterations in aspect ratio and orientation, following a normal distribution. This microfluidic chip provides a reliable tool for investigating cellular responses to the wide-ranging shear stress existing in both physiological and pathological flow conditions.
Collapse
Affiliation(s)
- Zhihang Yu
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Yiqun Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Jingjing Li
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, NSW, 2052, Australia
| | - Chang Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Huaxiu Lu
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Siyuan Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Tingting Zhang
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Tianruo Guo
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, NSW, 2052, Australia
| | - Yonggang Zhu
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Jing Jin
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China.
| | - Sheng Yan
- Institute for Advanced Study, Shenzhen University, Shenzhen, 518060, China.
| | - Huaying Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China.
| |
Collapse
|
4
|
Mukherjee J, Chaturvedi D, Mishra S, Jain R, Dandekar P. Microfluidic technology for cell biology-related applications: a review. J Biol Phys 2024; 50:1-27. [PMID: 38055086 PMCID: PMC10864244 DOI: 10.1007/s10867-023-09646-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 11/13/2023] [Indexed: 12/07/2023] Open
Abstract
Fluid flow at the microscale level exhibits a unique phenomenon that can be explored to fabricate microfluidic devices integrated with components that can perform various biological functions. In this manuscript, the importance of physics for microscale fluid dynamics using microfluidic devices has been reviewed. Microfluidic devices provide new opportunities with regard to spatial and temporal control over cell growth. Furthermore, the manuscript presents an overview of cellular stimuli observed by combining surfaces that mimic the complex biochemistries and different geometries of the extracellular matrix, with microfluidic channels regulating the transport of fluids, soluble factors, etc. We have also explained the concept of mechanotransduction, which defines the relation between mechanical force and biological response. Furthermore, the manipulation of cellular microenvironments by the use of microfluidic systems has been highlighted as a useful device for basic cell biology research activities. Finally, the article focuses on highly integrated microfluidic platforms that exhibit immense potential for biomedical and pharmaceutical research as robust and portable point-of-care diagnostic devices for the assessment of clinical samples.
Collapse
Affiliation(s)
- Joydeb Mukherjee
- Department of Biological Science and Biotechnology, Institute of Chemical Technology, Mumbai, 400019, India
| | - Deepa Chaturvedi
- Department of Pharmaceutical Sciences and Technology, Institute of Chemical Technology, Mumbai, 400019, India
| | - Shlok Mishra
- Department of Chemical Engineering, Institute of Chemical Technology, Mumbai, 400019, India
| | - Ratnesh Jain
- Department of Biological Science and Biotechnology, Institute of Chemical Technology, Mumbai, 400019, India
| | - Prajakta Dandekar
- Department of Pharmaceutical Sciences and Technology, Institute of Chemical Technology, Mumbai, 400019, India.
| |
Collapse
|
5
|
Gatto ML, Mengucci P, Mattioli-Belmonte M, Munteanu D, Nasini R, Tognoli E, Denti L, Gatto A. Features of Vat-Photopolymerized Masters for Microfluidic Device Manufacturing. Bioengineering (Basel) 2024; 11:80. [PMID: 38247957 PMCID: PMC10813418 DOI: 10.3390/bioengineering11010080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 12/23/2023] [Accepted: 01/09/2024] [Indexed: 01/23/2024] Open
Abstract
The growing interest in advancing microfluidic devices for manipulating fluids within micrometer-scale channels has prompted a shift in manufacturing practices, moving from single-component production to medium-size batches. This transition arises due to the impracticality of lab-scale manufacturing methods in accommodating the increased demand. This experimental study focuses on the design of master benchmarks 1-5, taking into consideration critical parameters such as rib width, height, and the relative width-to-height ratio. Notably, benchmarks 4 and 5 featured ribs that were strategically connected to the inlet, outlet, and reaction chamber of the master, enhancing their utility for subsequent replica production. Vat photopolymerization was employed for the fabrication of benchmarks 1-5, while replicas of benchmarks 4 and 5 were generated through polydimethylsiloxane casting. Dimensional investigations of the ribs and channels in both the master benchmarks and replicas were conducted using an optical technique validated through readability analysis based on the Michelson global contrast index. The primary goal was to evaluate the potential applicability of vat photopolymerization technology for efficiently producing microfluidic devices through a streamlined production process. Results indicate that the combination of vat photopolymerization followed by replication is well suited for achieving a minimum rib size of 25 µm in width and an aspect ratio of 1:12 for the master benchmark.
Collapse
Affiliation(s)
- Maria Laura Gatto
- Department of Industrial Engineering and Mathematical Sciences (DIISM), Università Politecnica delle Marche, Via Brecce Bianche 12, 60131 Ancona, Italy;
| | - Paolo Mengucci
- Department of Materials, Environmental Sciences and Urban Planning (SIMAU), Università Politecnica delle Marche, Via Brecce Bianche 12, 60131 Ancona, Italy;
| | - Monica Mattioli-Belmonte
- Department of Clinical and Molecular Sciences, Università Politecnica delle Marche, Via Tronto 10/a, 60126 Ancona, Italy;
- INSTM, National Consortium of Materials Science and Technology, Via G. Giusti 9, 50121 Florence, Italy
| | - Daniel Munteanu
- Material Science Department, Transilvania University of Brasov, 29 Eroilor Blvd., 500036 Brasov, Romania;
| | - Roberto Nasini
- Prosilas S.r.l., Via Terracini 14, 60212 Civitanova Marche, Italy
| | - Emanuele Tognoli
- Department of Engineering “Enzo Ferrari”, Università di Modena e Reggio Emilia, Via P. Vivarelli 10, 41125 Modena, Italy; (L.D.); (A.G.)
| | - Lucia Denti
- Department of Engineering “Enzo Ferrari”, Università di Modena e Reggio Emilia, Via P. Vivarelli 10, 41125 Modena, Italy; (L.D.); (A.G.)
| | - Andrea Gatto
- Department of Engineering “Enzo Ferrari”, Università di Modena e Reggio Emilia, Via P. Vivarelli 10, 41125 Modena, Italy; (L.D.); (A.G.)
| |
Collapse
|
6
|
Artemenko EO, Obydennyi SI, Troyanova KS, Novichkova GA, Nechipurenko DY, Panteleev MA. Adhesive properties of plasma-circulating and platelet-derived microvesicles from healthy individuals. Thromb Res 2024; 233:119-126. [PMID: 38039724 DOI: 10.1016/j.thromres.2023.11.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 10/31/2023] [Accepted: 11/15/2023] [Indexed: 12/03/2023]
Abstract
BACKGROUND Microvesicles (MVs) produced by platelets upon activation possess high procoagulant activity and represent a possible thrombotic risk marker. However, direct experimental evaluation of the adhesive properties of MVs and their potential role in thrombus growth is lacking. OBJECTIVES We investigated integrin αIIbβ3 status and adhesive properties of plasma-circulating and platelet-derived MVs from healthy individuals. METHODS MVs were isolated from whole blood or produced from activated platelets. Flow cytometry was used for quantification of fluorescently labeled PAC-1 and fibrinogen binding to MVs. Confocal microscopy was used for evaluation of MVs adhesion to fibrinogen and for estimation of their involvement in whole blood thrombus formation in a parallel-plate flow chambers under arterial shear conditions. RESULTS AND CONCLUSIONS Neither circulating plasma MVs, nor platelet-activation-produced MVs bound PAC-1. However, both types of MVs specifically and weakly bound fibrinogen (about 400 molecules of bound fibrinogen per MV versus >100,000 per non-procoagulant activated platelet). Still, the MVs did not adhere stably to the immobilized fibrinogen. Both types of MVs were weakly incorporated into a thrombus and did not affect thrombus formation: average thrombus height in the recalcified whole blood in the presence of platelet-activation-produced MVs was 4.19 ± 1.38 μm versus 4.87 ± 1.72 μm (n = 6, p > 0.05) in the control experiments. This suggests that MVs present in plasma of healthy individuals are not likely to be directly involved in thrombus formation under arterial flow conditions.
Collapse
Affiliation(s)
- E O Artemenko
- Centre for Theoretical Problems of Physicochemical Pharmacology, Moscow, Russia; National Scientific and Practical Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia.
| | - S I Obydennyi
- Centre for Theoretical Problems of Physicochemical Pharmacology, Moscow, Russia; National Scientific and Practical Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia
| | - K S Troyanova
- Centre for Theoretical Problems of Physicochemical Pharmacology, Moscow, Russia; Faculty of Physics, Moscow State University, Moscow, Russia
| | - G A Novichkova
- National Scientific and Practical Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia
| | - D Y Nechipurenko
- Centre for Theoretical Problems of Physicochemical Pharmacology, Moscow, Russia; National Scientific and Practical Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia; Faculty of Physics, Moscow State University, Moscow, Russia
| | - M A Panteleev
- Centre for Theoretical Problems of Physicochemical Pharmacology, Moscow, Russia; National Scientific and Practical Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia; Faculty of Physics, Moscow State University, Moscow, Russia
| |
Collapse
|
7
|
Zainal Abidin NA, Timofeeva M, Szydzik C, Akbaridoust F, Lav C, Marusic I, Mitchell A, Hamilton JR, Ooi AS, Nesbitt WS. A microfluidic method to investigate platelet mechanotransduction under extensional strain. Res Pract Thromb Haemost 2023; 7:100037. [PMID: 36846647 PMCID: PMC9944983 DOI: 10.1016/j.rpth.2023.100037] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Revised: 11/17/2022] [Accepted: 12/12/2022] [Indexed: 01/11/2023] Open
Abstract
Background Blood platelets have evolved a complex mechanotransduction machinery to rapidly respond to hemodynamic conditions. A variety of microfluidic flow-based approaches have been developed to explore platelet mechanotransduction; however, these experimental models primarily focus on the effects of increased wall shear stress on platelet adhesion events and do not consider the critical effects of extensional strain on platelet activation in free flow. Objectives We report the development and application of a hyperbolic microfluidic assay that allows for investigation of platelet mechanotransduction under quasi-homogenous extensional strain rates in the absence of surface adhesions. Methods Using a combined computational fluid dynamic and experimental microfluidic approach, we explore 5 extensional strain regimes (geometries) and their effect on platelet calcium signal transduction. Results We demonstrate that in the absence of canonical adhesion, receptor engagement platelets are highly sensitive to both initial increase and subsequent decrease in extensional strain rates within the range of 747 to 3319/s. Furthermore, we demonstrate that platelets rapidly respond to the rate of change in extensional strain and define a threshold of ≥7.33 × 106/s/m, with an optimal range of 9.21 × 107 to 1.32 × 108/s/m. In addition, we demonstrate a key role of both the actin-based cytoskeleton and annular microtubules in the modulation of extensional strain-mediated platelet mechanotransduction. Conclusion This method opens a window onto a novel platelet signal transduction mechanism and may have potential diagnostic utility in the identification of patients who are prone to thromboembolic complications associated with high-grade arterial stenosis or are on mechanical circulatory support systems, for which the extensional strain rate is a predominant hemodynamic driver.
Collapse
Affiliation(s)
- Nurul A. Zainal Abidin
- The Australian Centre for Blood Diseases, Central Clinical School, Monash University, Melbourne, Victoria, Australia
| | - Mariia Timofeeva
- Department of Mechanical Engineering, Faculty of Engineering and Information Technology, The University of Melbourne, Melbourne, Victoria, Australia
| | - Crispin Szydzik
- The Australian Centre for Blood Diseases, Central Clinical School, Monash University, Melbourne, Victoria, Australia
- School of Engineering, RMIT University, Melbourne, Victoria, Australia
| | - Farzan Akbaridoust
- Department of Mechanical Engineering, Faculty of Engineering and Information Technology, The University of Melbourne, Melbourne, Victoria, Australia
| | - Chitrarth Lav
- Department of Mechanical Engineering, Faculty of Engineering and Information Technology, The University of Melbourne, Melbourne, Victoria, Australia
- Scuderia AlphaTauri F1, Bicester, UK
| | - Ivan Marusic
- Department of Mechanical Engineering, Faculty of Engineering and Information Technology, The University of Melbourne, Melbourne, Victoria, Australia
| | - Arnan Mitchell
- School of Engineering, RMIT University, Melbourne, Victoria, Australia
| | - Justin R. Hamilton
- The Australian Centre for Blood Diseases, Central Clinical School, Monash University, Melbourne, Victoria, Australia
| | - Andrew S.H. Ooi
- Department of Mechanical Engineering, Faculty of Engineering and Information Technology, The University of Melbourne, Melbourne, Victoria, Australia
| | - Warwick S. Nesbitt
- The Australian Centre for Blood Diseases, Central Clinical School, Monash University, Melbourne, Victoria, Australia
- Correspondence Warwick S. Nesbitt, The Australian Centre for Blood Diseases, Monash University, 99 Commercial Road, Melbourne, Victoria 3004, Australia.
| |
Collapse
|
8
|
Extracting Mural and Volumetric Growth Patterns of Platelet Aggregates on Engineered Surfaces by Use of an Entity Tracking Algorithm. ASAIO J 2022; 69:382-390. [PMID: 36302265 PMCID: PMC10065893 DOI: 10.1097/mat.0000000000001841] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Thrombosis is a major complication that can occur in both blood-contacting devices and regions and in regions of vascular damage. Microfluidic devices are popular templates to model various thrombogenic settings and to assess conditions that lead to bulk channel occlusion. However, area-averaged measurements miss the opportunity to extract real-time information on thrombus evolution and early dynamics of thrombus formation and propagation, which result in late-stage bulk channel occlusion. To clarify these dynamics, we have developed a standalone tracking algorithm that uses consecutive image connectivity and minimal centroid distance mappings to uniquely index all appearing thrombi in fluorescence time-lapse videos http://links.lww.com/ASAIO/A887 , and http://links.lww.com/ASAIO/A888 . This leads to measurements of all individual aggregates that can in turn be studied as ensembles. We applied tracking to fluorescence time-lapse videos http://links.lww.com/ASAIO/A887 , and http://links.lww.com/ASAIO/A888 of thrombosis across both collagen-functionalized substrate and across the surface of a roughened titanium alloy (Ti6Al4V) at a shear rate of 4000 s -1 . When comparing ensemble-averaged measurements to area-averaged metrics, we unveil immediate, steady thrombus growth at early phases on collagen surfaces and unstable thrombus attachment to roughened Ti6Al4V surfaces on Ti6Al4V surfaces. Additionally, we introduce tracked thrombus eccentricity and fluorescence intensity as additional volumetric measures of thrombus growth that relate back to the primary thrombosis mechanism at play. This work advocates for the complementation of surface macrostate metrics with characteristic thrombus microstate growth patterns to accurately predict critical thrombosis events.
Collapse
|
9
|
Major R, Wilczek G, Więcek J, Gawlikowski M, Plutecka H, Kasperkiewicz K, Kot M, Pomorska M, Ostrowski R, Kopernik M. Hemocompatibile Thin Films Assessed under Blood Flow Shear Forces. Molecules 2022; 27:molecules27175696. [PMID: 36080463 PMCID: PMC9458224 DOI: 10.3390/molecules27175696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 08/23/2022] [Accepted: 09/01/2022] [Indexed: 11/16/2022] Open
Abstract
The aim of this study was to minimize the risk of life-threatening thromboembolism in the ventricle through the use of a new biomimetic heart valve based on metal-polymer composites. Finite volume element simulations of blood adhesion to the material were carried out, encompassing radial flow and the cone and plane test together with determination of the effect of boundary conditions. Both tilt-disc and bicuspid valves do not have optimized blood flow due to their design based on rigid valve materials (leaflet made of pyrolytic carbon). The main objective was the development of materials with specific properties dedicated to contact with blood. Materials were evaluated by dynamic tests using blood, concentrates, and whole human blood. Hemostability tests under hydrodynamic conditions were related to the mechanical properties of thin-film materials obtained from tribological tests. The quality of the coatings was high enough to avoid damage to the coating even as they were exposed up to maximum loading. Analysis towards blood concentrates of the hydrogenated carbon sample and the nitrogen-doped hydrogenated carbon sample revealed that the interaction of the coating with erythrocytes was the strongest. Hemocompatibility evaluation under hydrodynamic conditions confirmed very good properties of the developed coatings.
Collapse
Affiliation(s)
- Roman Major
- Institute of Metallurgy and Materials Science, Polish Academy of Sciences, 25 Reymonta St., 30-059 Cracow, Poland
| | - Grażyna Wilczek
- Institute of Biology, Biotechnology and Environmental Protection, University of Silesia, Bankowa St. 9, 40-007 Katowice, Poland
| | - Justyna Więcek
- Institute of Metallurgy and Materials Science, Polish Academy of Sciences, 25 Reymonta St., 30-059 Cracow, Poland
| | - Maciej Gawlikowski
- Faculty of Biomedical Engineering, Department of Biosensors and Processing of Biomedical Signals, Silesian University of Technology, Roosevelt St. 40, 41-800 Zabrze, Poland
| | - Hanna Plutecka
- Division of Molecular Biology and Clinical Genetics, Faculty of Medicine, Jagiellonian University Medical College, Skawinska St. 8, 31-066 Cracow, Poland
| | - Katarzyna Kasperkiewicz
- Institute of Biology, Biotechnology and Environmental Protection, Faculty of Natural Sciences, University of Silesia in Katowice, Jagiellońska St., 2840-032 Katowice, Poland
| | - Marcin Kot
- Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow, Poland
| | - Małgorzata Pomorska
- Institute of Metallurgy and Materials Science, Polish Academy of Sciences, 25 Reymonta St., 30-059 Cracow, Poland
| | - Roman Ostrowski
- Institute of Optoelectronics, Military University of Technology, Gen. S. Kaliskiego St. 2, 00-908 Warsaw, Poland
| | - Magdalena Kopernik
- Faculty of Metals Engineering and Industrial Computer Science, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow, Poland
- Correspondence: ; Tel.: +48-12-617-51-26
| |
Collapse
|
10
|
Meng F, Cheng H, Qian J, Dai X, Huang Y, Fan Y. In vitro fluidic systems: Applying shear stress on endothelial cells. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2022. [DOI: 10.1016/j.medntd.2022.100143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
11
|
Microscopic Imaging Methods for Organ-on-a-Chip Platforms. MICROMACHINES 2022; 13:mi13020328. [PMID: 35208453 PMCID: PMC8879989 DOI: 10.3390/mi13020328] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 02/15/2022] [Accepted: 02/15/2022] [Indexed: 02/06/2023]
Abstract
Microscopic imaging is essential and the most popular method for in situ monitoring and evaluating the outcome of various organ-on-a-chip (OOC) platforms, including the number and morphology of mammalian cells, gene expression, protein secretions, etc. This review presents an overview of how various imaging methods can be used to image organ-on-a-chip platforms, including transillumination imaging (including brightfield, phase-contrast, and holographic optofluidic imaging), fluorescence imaging (including confocal fluorescence and light-sheet fluorescence imaging), and smartphone-based imaging (including microscope attachment-based, quantitative phase, and lens-free imaging). While various microscopic imaging methods have been demonstrated for conventional microfluidic devices, a relatively small number of microscopic imaging methods have been demonstrated for OOC platforms. Some methods have rarely been used to image OOCs. Specific requirements for imaging OOCs will be discussed in comparison to the conventional microfluidic devices and future directions will be introduced in this review.
Collapse
|
12
|
Zhang Y, Jiang F, Chen Y, Ju LA. Platelet Mechanobiology Inspired Microdevices: From Hematological Function Tests to Disease and Drug Screening. Front Pharmacol 2022; 12:779753. [PMID: 35126120 PMCID: PMC8811026 DOI: 10.3389/fphar.2021.779753] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Accepted: 12/28/2021] [Indexed: 12/30/2022] Open
Abstract
Platelet function tests are essential to profile platelet dysfunction and dysregulation in hemostasis and thrombosis. Clinically they provide critical guidance to the patient management and therapeutic evaluation. Recently, the biomechanical effects induced by hemodynamic and contractile forces on platelet functions attracted increasing attention. Unfortunately, the existing platelet function tests on the market do not sufficiently incorporate the topical platelet mechanobiology at play. Besides, they are often expensive and bulky systems that require large sample volumes and long processing time. To this end, numerous novel microfluidic technologies emerge to mimic vascular anatomies, incorporate hemodynamic parameters and recapitulate platelet mechanobiology. These miniaturized and cost-efficient microfluidic devices shed light on high-throughput, rapid and scalable platelet function testing, hematological disorder profiling and antiplatelet drug screening. Moreover, the existing antiplatelet drugs often have suboptimal efficacy while incurring several adverse bleeding side effects on certain individuals. Encouraged by a few microfluidic systems that are successfully commercialized and applied to clinical practices, the microfluidics that incorporate platelet mechanobiology hold great potential as handy, efficient, and inexpensive point-of-care tools for patient monitoring and therapeutic evaluation. Hereby, we first summarize the conventional and commercially available platelet function tests. Then we highlight the recent advances of platelet mechanobiology inspired microfluidic technologies. Last but not least, we discuss their future potential of microfluidics as point-of-care tools for platelet function test and antiplatelet drug screening.
Collapse
Affiliation(s)
- Yingqi Zhang
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Sydney, NSW, Australia
- Charles Perkins Centre, The University of Sydney, Camperdown, NSW, Australia
- Heart Research Institute, Newtown, NSW, Australia
| | - Fengtao Jiang
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Sydney, NSW, Australia
| | - Yunfeng Chen
- The Department of Biochemistry and Molecular Biology, The University of Texas Medical Branch, Galveston, TX, United States
- The Department of Pathology, The University of Texas Medical Branch, Galveston, TX, United States
| | - Lining Arnold Ju
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Sydney, NSW, Australia
- Charles Perkins Centre, The University of Sydney, Camperdown, NSW, Australia
- Heart Research Institute, Newtown, NSW, Australia
- *Correspondence: Lining Arnold Ju,
| |
Collapse
|
13
|
Zhang Y, Ramasundara SDZ, Preketes-Tardiani RE, Cheng V, Lu H, Ju LA. Emerging Microfluidic Approaches for Platelet Mechanobiology and Interplay With Circulatory Systems. Front Cardiovasc Med 2021; 8:766513. [PMID: 34901226 PMCID: PMC8655735 DOI: 10.3389/fcvm.2021.766513] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Accepted: 10/15/2021] [Indexed: 12/29/2022] Open
Abstract
Understanding how platelets can sense and respond to hemodynamic forces in disturbed blood flow and complexed vasculature is crucial to the development of more effective and safer antithrombotic therapeutics. By incorporating diverse structural and functional designs, microfluidic technologies have emerged to mimic microvascular anatomies and hemodynamic microenvironments, which open the floodgates for fascinating platelet mechanobiology investigations. The latest endothelialized microfluidics can even recapitulate the crosstalk between platelets and the circulatory system, including the vessel walls and plasma proteins such as von Willebrand factor. Hereby, we highlight these exciting microfluidic applications to platelet mechanobiology and platelet–circulatory system interplay as implicated in thrombosis. Last but not least, we discuss the need for microfluidic standardization and summarize the commercially available microfluidic platforms for researchers to obtain reproducible and consistent results in the field.
Collapse
Affiliation(s)
- Yingqi Zhang
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Darlington, NSW, Australia.,Charles Perkins Centre, The University of Sydney, Camperdown, NSW, Australia.,Heart Research Institute, Newtown, NSW, Australia
| | - Savindi De Zoysa Ramasundara
- Charles Perkins Centre, The University of Sydney, Camperdown, NSW, Australia.,Heart Research Institute, Newtown, NSW, Australia.,School of Medicine, The University of Notre Dame Sydney, Darlinghurst, NSW, Australia
| | - Renee Ellen Preketes-Tardiani
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Darlington, NSW, Australia.,Charles Perkins Centre, The University of Sydney, Camperdown, NSW, Australia.,Heart Research Institute, Newtown, NSW, Australia
| | - Vivian Cheng
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Darlington, NSW, Australia
| | - Hongxu Lu
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Darlington, NSW, Australia.,Faculty of Science, Institute for Biomedical Materials and Devices, The University of Technology Sydney, Ultimo, NSW, Australia
| | - Lining Arnold Ju
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Darlington, NSW, Australia.,Charles Perkins Centre, The University of Sydney, Camperdown, NSW, Australia.,Heart Research Institute, Newtown, NSW, Australia
| |
Collapse
|
14
|
Nguyen N, Thurgood P, Sekar NC, Chen S, Pirogova E, Peter K, Baratchi S, Khoshmanesh K. Microfluidic models of the human circulatory system: versatile platforms for exploring mechanobiology and disease modeling. Biophys Rev 2021; 13:769-786. [PMID: 34777617 DOI: 10.1007/s12551-021-00815-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Accepted: 06/22/2021] [Indexed: 02/07/2023] Open
Abstract
The human circulatory system is a marvelous fluidic system, which is very sensitive to biophysical and biochemical cues. The current animal and cell culture models do not recapitulate the functional properties of the human circulatory system, limiting our ability to fully understand the complex biological processes underlying the dysfunction of this multifaceted system. In this review, we discuss the unique ability of microfluidic systems to recapitulate the biophysical, biochemical, and functional properties of the human circulatory system. We also describe the remarkable capacity of microfluidic technologies for exploring the complex mechanobiology of the cardiovascular system, mechanistic studying of cardiovascular diseases, and screening cardiovascular drugs with the additional benefit of reducing the need for animal models. We also discuss opportunities for further advancement in this exciting field.
Collapse
Affiliation(s)
- Ngan Nguyen
- School of Engineering, RMIT University, Melbourne, Australia
| | - Peter Thurgood
- School of Engineering, RMIT University, Melbourne, Australia
| | - Nadia Chandra Sekar
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Australia
| | - Sheng Chen
- School of Engineering, RMIT University, Melbourne, Australia
| | - Elena Pirogova
- School of Engineering, RMIT University, Melbourne, Australia
| | - Karlheinz Peter
- Baker Heart and Diabetes Institute, Melbourne, Australia.,Department of Cardiometabolic Health, The University of Melbourne, Parkville, Australia
| | - Sara Baratchi
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Australia
| | | |
Collapse
|
15
|
Gabbasov ZA, Avtaeva YN, Melnikov IS, Okhota SD, Caprnda M, Mozos I, Prosecky R, Rodrigo L, Kruzliak P, Zozulya NI. Kinetics of platelet adhesion to a fibrinogen-coated surface in whole blood under flow conditions. J Clin Lab Anal 2021; 35:e23939. [PMID: 34347925 PMCID: PMC8418503 DOI: 10.1002/jcla.23939] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 07/19/2021] [Accepted: 07/24/2021] [Indexed: 12/25/2022] Open
Abstract
Aim To test a novel method of assessment of platelet adhesion to a fibrinogen‐coated surface in whole blood under flow conditions. Methods We developed a fluidic device that mimics blood flow in vessels. The method of detection of platelet adhesion is based on recording of a scattered laser light signal from a fibrinogen‐covered surface. Testing was performed in platelet‐rich plasma (PRP) and whole blood of healthy volunteers. Control measurements were performed, followed by tests with inhibition of platelet GPIIa/IIIb and GPIb receptors. Then, the same testing sequence was performed in whole blood of persons with autoimmune thrombocytopenia and type 3 von Willebrand disease. Results The change in intensity of scattered light was 2.7 (2.4; 4.1) times higher in whole blood (0.2 ± 0.08V, n = 7) than in PRP (0.05 ± 0.02 V, n = 7), p < 0.01. The blocking of GP IIb/IIIa receptors decreased the intensity of scattered light to 8.5 (6.5;12)%; the blocking of GPIb receptors decreased it to 34 (23;58)%, p < 0.01. In the whole blood of a person with autoimmune thrombocytopenia, the inhibition of GPIb receptors decreased platelet adhesion, but no effect was observed in type 3 von Willebrand disease. Inhibition of platelet GPIIb/IIIa receptors alone or combined inhibition of GPIb and GPIIb/IIIa receptors resulted in almost total suppression of adhesion in both cases. Conclusion Our system effectively registers platelet adhesion to a fibrinogen‐coated surface under controlled‐flow conditions and may successfully be applied to the investigation of platelet adhesion kinetics.
Collapse
Affiliation(s)
- Zufar A Gabbasov
- National Medical Research Centre for Cardiology of the Ministry of Health of the Russian Federation, Moscow, Russia
| | - Yuliya N Avtaeva
- National Medical Research Centre for Cardiology of the Ministry of Health of the Russian Federation, Moscow, Russia
| | - Ivan S Melnikov
- National Medical Research Centre for Cardiology of the Ministry of Health of the Russian Federation, Moscow, Russia.,Institute of Biomedical Problems of Russian Academy of Sciences, Moscow, Russia
| | - Sergey D Okhota
- National Medical Research Centre for Cardiology of the Ministry of Health of the Russian Federation, Moscow, Russia
| | - Martin Caprnda
- 1st Department of Internal Medicine, Faculty of Medicine, Comenius University and University Hospital, Bratislava, Slovakia
| | - Ioana Mozos
- Department of Functional Sciences, "Victor Babes" University of Medicine and Pharmacy, Timisoara, Romania.,Center for Translational Research and Systems Medicine, "Victor Babes" University of Medicine and Pharmacy, Timisoara, Romania
| | - Robert Prosecky
- 2nd Department of Internal Medicine, Faculty of Medicine, Masaryk University and St, Anne´s University Hospital, Brno, Czech Republic
| | - Luis Rodrigo
- Faculty of Medicine, University of Oviedo and Central University Hospital of Asturias (HUCA), Oviedo, Spain
| | - Peter Kruzliak
- 2nd Department of Surgery, Faculty of Medicine, Masaryk University and St, Anne´s University Hospital, Brno, Czech Republic
| | - Nadezhda I Zozulya
- National Research Center for Hematology of the Ministry of Health of the Russian Federation, Moscow, Russia
| |
Collapse
|
16
|
Caruso C, Lam WA. Point-of-Care Diagnostic Assays and Novel Preclinical Technologies for Hemostasis and Thrombosis. Semin Thromb Hemost 2021; 47:120-128. [PMID: 33636744 DOI: 10.1055/s-0041-1723798] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Hemostasis is a complex wound-healing process involving numerous mechanical and biochemical mechanisms and influenced by many factors including platelets, coagulation factors, and endothelial components. Slight alterations in these mechanisms can lead to either prothrombotic or bleeding consequences, and such hemostatic imbalances can lead to significant clinical consequences with resultant morbidity and mortality. An ideal hemostasis assay would not only address all the unique processes involved in clot formation and resolution but also take place under flow conditions to account for endothelial involvement. Global assays do exist; however, these assays are not flow based. Flow-based assays have been limited secondary to their large blood volume requirements and low throughput, limiting potential clinical applications. Microfluidic-based assays address the aforementioned limitations of both global and flow-based assays by utilizing standardized devices that require low blood volumes, offer reproducible analysis, and have functionality under a range of shear stresses and flow conditions. While still largely confined to the preclinical space, here we aim to discuss these novel technologies and potential clinical implications, particularly in comparison to the current, commercially available point-of-care assays.
Collapse
Affiliation(s)
- Christina Caruso
- Department of Pediatrics, Aflac Cancer and Blood Disorders Center of Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, Georgia
| | - Wilbur A Lam
- Department of Pediatrics, Aflac Cancer and Blood Disorders Center of Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, Georgia.,Wallace H. Coulter Department of Biomedical Engineering, Emory University School of Medicine, Georgia Institute of Technology, Atlanta, Georgia
| |
Collapse
|
17
|
Beverung S, Wu J, Steward R. Lab-on-a-Chip for Cardiovascular Physiology and Pathology. MICROMACHINES 2020; 11:E898. [PMID: 32998305 PMCID: PMC7600691 DOI: 10.3390/mi11100898] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 09/09/2020] [Accepted: 09/24/2020] [Indexed: 02/08/2023]
Abstract
Lab-on-a-chip technologies have allowed researchers to acquire a flexible, yet relatively inexpensive testbed to study one of the leading causes of death worldwide, cardiovascular disease. Cardiovascular diseases, such as peripheral artery disease, arteriosclerosis, and aortic stenosis, for example, have all been studied by lab-on-a-chip technologies. These technologies allow for the integration of mammalian cells into functional structures that mimic vital organs with geometries comparable to those found in vivo. For this review, we focus on microdevices that have been developed to study cardiovascular physiology and pathology. With these technologies, researchers can better understand the electrical-biomechanical properties unique to cardiomyocytes and better stimulate and understand the influence of blood flow on the human vasculature. Such studies have helped increase our understanding of many cardiovascular diseases in general; as such, we present here a review of the current state of the field and potential for the future.
Collapse
Affiliation(s)
| | | | - Robert Steward
- Department of Mechanical and Aerospace Engineering, Burnett School of Biomedical Sciences, University of Central Florida, Orlando, FL 32816, USA; (S.B.); (J.W.)
| |
Collapse
|
18
|
Trembecka-Wójciga K, Kopernik M, Surmiak M, Major R, Gawlikowski M, Bruckert F, Kot M, Lackner JM. Effect of the mechanical properties of carbon-based coatings on the mechanics of cell-material interactions. Colloids Surf B Biointerfaces 2020; 197:111359. [PMID: 33032179 DOI: 10.1016/j.colsurfb.2020.111359] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 08/31/2020] [Accepted: 09/02/2020] [Indexed: 12/28/2022]
Abstract
The paper presents an influence of the surface mechanical properties of thin-film materials on blood cell adhesion under shear stress conditions. Physical vapour deposited (PVD) coatings i.e. hydrogenated amorphous carbon (a-C:H) doped with nitrogen or silicon have been investigated. The mechanical properties of materials, namely their microhardness and Young's modulus were measured using indentation test with Rockwell indenter. The adhesion efficiency of blood cells in dynamic conditions were analysed using a radial flow chamber. Red blood cells (RBC) were used as representative cells to analyse cell-material interactions. The biomaterial examinations were performed under physiological flow conditions at the single-cell level. The 3D FVM (finite volume method) model of multi-phase radial flow test was developed to reproduce the physical test and to predict distributions of shear stresses and velocity during blood washout with PBS. Cell-material interactions were found to be strongly associated with the mechanical properties of the thin-film material. The decrease in the hardness of the coatings translated into a weaker cell - material interactions.
Collapse
Affiliation(s)
- K Trembecka-Wójciga
- Institute of Metallurgy and Materials Science, Polish Academy of Sciences, Reymonta St. 25, Cracow, Poland
| | - M Kopernik
- AGH University of Science and Technology, Mickiewicza Str. 30, Cracow, Poland.
| | - M Surmiak
- Department of Internal Medicine, Jagiellonian University Medical College, Skawinska Str. 8, Cracow, Poland
| | - R Major
- Institute of Metallurgy and Materials Science, Polish Academy of Sciences, Reymonta St. 25, Cracow, Poland
| | - M Gawlikowski
- Silesian University of Technology, Faculty of Biomedical Engineering, Department of Biosensors and Processing of Biomedical Signals, Roosevelt Str. 40, Zabrze, Poland
| | - F Bruckert
- Laboratoire des Matériaux et du Génie Physique - UMR 5628, 3 parvis Louis Néel, Grenoble Cedex 1, France
| | - M Kot
- Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Mickiewicza Str. 30, Cracow, Poland
| | - J M Lackner
- Joanneum Research Forschungsges mbH, Institute of Surface Technologies and Photonics, Functional Surfaces, Leobner Strasse 94, A-8712, Niklasdorf, Austria
| |
Collapse
|
19
|
Abstract
Recent advances in super-resolution (sub-diffraction limited) microscopy have yielded remarkable insights into the nanoscale architecture and behavior of cells. In addition to the capacity to provide sub 100 nm resolution, these technologies offer unique quantitative opportunities with particular relevance to platelet and megakaryocyte biology. In this review, we provide a short introduction to modern super-resolution microscopy, its applications in the field of platelet and megakaryocyte biology, and emerging quantitative approaches which will allow for unprecedented insights into the biology of these unique cell types.
Collapse
Affiliation(s)
- Abdullah O Khan
- Institute of Cardiovascular Sciences, College of Medical and Dental Science, University of Birmingham , Birmingham, UK
| | - Jeremy A Pike
- Institute of Cardiovascular Sciences, College of Medical and Dental Science, University of Birmingham , Birmingham, UK.,Centre of Membrane Proteins and Receptors, Universities of Birmingham and Nottingham , UK
| |
Collapse
|
20
|
Park SJ, Yoon J, Seo HS, Lim CS. Performance evaluation of the Anysis-200 platelet function analyzer in cardiac patients. Clin Hemorheol Microcirc 2020; 80:17-24. [DOI: 10.3233/ch-190801] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Seong Jun Park
- Department of Laboratory Medicine, College of Medicine, Korea University Seoul, South Korea
| | - Jung Yoon
- Department of Laboratory Medicine, College of Medicine, Korea University Seoul, South Korea
| | - Hong Seog Seo
- Division of Cardiology, Internal Medicine, College of Medicine, Korea University Seoul, South Korea
| | - Chae Seung Lim
- Department of Laboratory Medicine, College of Medicine, Korea University Seoul, South Korea
| |
Collapse
|
21
|
Jigar Panchal H, Kent NJ, Knox AJS, Harris LF. Microfluidics in Haemostasis: A Review. Molecules 2020; 25:E833. [PMID: 32075008 PMCID: PMC7070452 DOI: 10.3390/molecules25040833] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 02/11/2020] [Accepted: 02/12/2020] [Indexed: 12/17/2022] Open
Abstract
Haemostatic disorders are both complex and costly in relation to both their treatment and subsequent management. As leading causes of mortality worldwide, there is an ever-increasing drive to improve the diagnosis and prevention of haemostatic disorders. The field of microfluidic and Lab on a Chip (LOC) technologies is rapidly advancing and the important role of miniaturised diagnostics is becoming more evident in the healthcare system, with particular importance in near patient testing (NPT) and point of care (POC) settings. Microfluidic technologies present innovative solutions to diagnostic and clinical challenges which have the knock-on effect of improving health care and quality of life. In this review, both advanced microfluidic devices (R&D) and commercially available devices for the diagnosis and monitoring of haemostasis-related disorders and antithrombotic therapies, respectively, are discussed. Innovative design specifications, fabrication techniques, and modes of detection in addition to the materials used in developing micro-channels are reviewed in the context of application to the field of haemostasis.
Collapse
Affiliation(s)
- Heta Jigar Panchal
- School of Biological and Health Sciences, Technological University Dublin (TU Dublin) - City Campus, Kevin Street, Dublin D08 NF82, Ireland; (H.J.P.); (A.J.S.K.)
| | - Nigel J Kent
- engCORE, Faculty of Engineering, Institute of Technology Carlow, Kilkenny Road, Carlow R93 V960, Ireland;
| | - Andrew J S Knox
- School of Biological and Health Sciences, Technological University Dublin (TU Dublin) - City Campus, Kevin Street, Dublin D08 NF82, Ireland; (H.J.P.); (A.J.S.K.)
| | - Leanne F Harris
- School of Biological and Health Sciences, Technological University Dublin (TU Dublin) - City Campus, Kevin Street, Dublin D08 NF82, Ireland; (H.J.P.); (A.J.S.K.)
| |
Collapse
|
22
|
Platelet Adhesion and Thrombus Formation in Microchannels: The Effect of Assay-Dependent Variables. Int J Mol Sci 2020; 21:ijms21030750. [PMID: 31979370 PMCID: PMC7037340 DOI: 10.3390/ijms21030750] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 01/13/2020] [Accepted: 01/21/2020] [Indexed: 12/12/2022] Open
Abstract
Microfluidic flow chambers (MFCs) allow the study of platelet adhesion and thrombus formation under flow, which may be influenced by several variables. We developed a new MFC, with which we tested the effects of different variables on the results of platelet deposition and thrombus formation on a collagen-coated surface. Methods: Whole blood was perfused in the MFC over collagen Type I for 4 min at different wall shear rates (WSR) and different concentrations of collagen-coating solutions, keeping blood samples at room temperature or 37 °C before starting the experiments. In addition, we tested the effects of the antiplatelet agent acetylsalicylic acid (ASA) (antagonist of cyclooxygenase-1, 100 µM) and cangrelor (antagonist of P2Y12, 1 µM). Results: Platelet deposition on collagen (I) was not affected by the storage temperature of the blood before perfusion (room temperature vs. 37 °C); (II) was dependent on a shear rate in the range between 300/s and 1700/s; and (III) was influenced by the collagen concentration used to coat the microchannels up to a value of 10 µg/mL. ASA and cangrelor did not cause statistically significant inhibition of platelet accumulation, except for ASA at low collagen concentrations. Conclusions: Platelet deposition on collagen-coated surfaces is a shear-dependent process, not influenced by the collagen concentration beyond a value of 10 µg/mL. However, the inhibitory effect of antiplatelet drugs is better observed using low concentrations of collagen.
Collapse
|
23
|
Laser speckle decorrelation time-based platelet function testing in microfluidic system. Sci Rep 2019; 9:16514. [PMID: 31712610 PMCID: PMC6848072 DOI: 10.1038/s41598-019-52953-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Accepted: 10/24/2019] [Indexed: 11/10/2022] Open
Abstract
Platelet aggregation and adhesion are critically involved in both normal hemostasis and thrombosis during vascular injury. Before any surgery, it is important to identify the number of platelets and their functionality to reduce the risk of bleeding; therefore, platelet function testing is a requirement. We introduce a novel evaluation method of assessing platelet function with laser speckle contrast imaging. The speckle decorrelation time (SDT) of the blood flowing through a microfluidic channel chip provides a quantitative measure of platelet aggregation. We compared SDTs of whole blood and platelet-poor blood, i.e., whole blood stripped of its buffy coat region, and found a marked reduction in decorrelation time for platelet-poor blood. The measured SDT of platelet-poor blood was 1.04 ± 0.21 ms, while that of whole blood was 2.64 ± 0.83 ms. To further characterize the sensitivity of our speckle decorrelation time-based platelet function testing (SDT-PFT), we added various agonists involved in platelet aggregation, including adenosine diphosphate (ADP), epinephrine (EPI), and arachidonic acid (AA). In this study, the results show that whole blood with ADP resulted in the largest SDT, followed by whole blood with AA, whole blood with EPI, whole blood without agonist, and platelet-poor blood with or without agonist. These findings show that SDT-PFT has the potential for rapid screening of bleeding disorders and monitoring of anti-platelet therapies with only a small volume of blood.
Collapse
|
24
|
Szydzik C, Brazilek RJ, Akbaridoust F, de Silva C, Moon M, Marusic I, Ooi ASH, Nandurkar HH, Hamilton JR, Mitchell A, Nesbitt WS. Active Micropump-Mixer for Rapid Antiplatelet Drug Screening in Whole Blood. Anal Chem 2019; 91:10830-10839. [PMID: 31343155 DOI: 10.1021/acs.analchem.9b02486] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
There is a need for scalable automated lab-on-chip systems incorporating precise hemodynamic control that can be applied to high-content screening of new more efficacious antiplatelet therapies. This paper reports on the development and characterization of a novel active micropump-mixer microfluidic to address this need. Using a novel reciprocating elastomeric micropump design, we take advantage of the flexible structural and actuation properties of this framework to manage the hemodynamics for on-chip platelet thrombosis assay on type 1 fibrillar collagen, using whole blood. By characterizing and harnessing the complex three-dimensional hemodynamics of the micropump operation in conjunction with a microvalve controlled reagent injection system we demonstrate that this prototype can act as a real-time assay of antiplatelet drug pharmacokinetics. In a proof-of-concept preclinical application, we utilize this system to investigate the way in which rapid dosing of human whole blood with isoform selective inhibitors of phosphatidylinositol 3-kinase dose dependently modulate platelet thrombus dynamics. This modular system exhibits utility as an automated multiplexable assay system with applications to high-content chemical library screening of new antiplatelet therapies.
Collapse
Affiliation(s)
- Crispin Szydzik
- The Australian Centre for Blood Diseases , Monash University , 99 Commercial Road , Melbourne , Victoria 3004 , Australia.,School of Engineering , RMIT University , 124 La Trobe Street , Melbourne , Victoria 3000 , Australia
| | - Rose J Brazilek
- The Australian Centre for Blood Diseases , Monash University , 99 Commercial Road , Melbourne , Victoria 3004 , Australia
| | - Farzan Akbaridoust
- School of Engineering , RMIT University , 124 La Trobe Street , Melbourne , Victoria 3000 , Australia.,Department of Mechanical Engineering, Melbourne School of Engineering , The University of Melbourne , Melbourne , Victoria 3010 , Australia
| | - Charitha de Silva
- Department of Mechanical Engineering, Melbourne School of Engineering , The University of Melbourne , Melbourne , Victoria 3010 , Australia.,School of Mechanical and Manufacturing Engineering , The University of New South Wales , Sydney , New South Wales 2052 , Australia
| | - Mitchell Moon
- The Australian Centre for Blood Diseases , Monash University , 99 Commercial Road , Melbourne , Victoria 3004 , Australia
| | - Ivan Marusic
- Department of Mechanical Engineering, Melbourne School of Engineering , The University of Melbourne , Melbourne , Victoria 3010 , Australia
| | - Andrew S H Ooi
- Department of Mechanical Engineering, Melbourne School of Engineering , The University of Melbourne , Melbourne , Victoria 3010 , Australia
| | - Harshal H Nandurkar
- The Australian Centre for Blood Diseases , Monash University , 99 Commercial Road , Melbourne , Victoria 3004 , Australia
| | - Justin R Hamilton
- The Australian Centre for Blood Diseases , Monash University , 99 Commercial Road , Melbourne , Victoria 3004 , Australia
| | - Arnan Mitchell
- School of Engineering , RMIT University , 124 La Trobe Street , Melbourne , Victoria 3000 , Australia
| | - Warwick S Nesbitt
- The Australian Centre for Blood Diseases , Monash University , 99 Commercial Road , Melbourne , Victoria 3004 , Australia.,School of Engineering , RMIT University , 124 La Trobe Street , Melbourne , Victoria 3000 , Australia
| |
Collapse
|
25
|
Microfluidic models of physiological or pathological flow shear stress for cell biology, disease modeling and drug development. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.06.023] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
26
|
Tan A, Lam YY, Pacot O, Hawley A, Boyd BJ. Probing cell-nanoparticle (cubosome) interactions at the endothelial interface: do tissue dimension and flow matter? Biomater Sci 2019; 7:3460-3470. [PMID: 31268062 DOI: 10.1039/c9bm00243j] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
In the research field of nanostructured systems for biomedical applications, increasing attention has been paid to using biomimetic, dynamic cellular models to adequately predict their bio-nano behaviours. This work specifically evaluates the biointeractions of nanostructured lipid-based particles (cubosomes) with human vascular cells from the aspects of tissue dimension (conventional 2D well plate versus 3D dynamic tubular vasculature) and shear flow effect (static, venous and arterial flow-mimicking conditions). A glass capillary-hosted, 3D tubular endothelial construct was coupled with circulating luminal fluid flow to simulate the human vascular systems. In the absence of fluid flow, the degree of cell-cubosome association was not significantly different between the 2D planar and the 3D tubular systems. Under flow conditions simulating venous (0.8 dynes per cm2) and arterial (10 dynes per cm2) shear stresses, the cell-cubosome association notably declined by 50% and 98%, respectively. This highlights the significance of shear-guided biointeractions of non-targeted nanoparticles in the circulation. Across all 2D and 3D cellular models with and without flow, cubosomes had little effect on the cell-cell contact based on the unchanged immunoexpression of the endothelial-specific intercellular junction marker PECAM-1. Interestingly, there were dissimilar nanoparticle distribution patterns between the 2D planar (showing discrete punctate staining) and the 3D tubular endothelium (with a more diffused, patchy fashion). Taken together, these findings highlight the importance of tissue dimension and shear flow in governing the magnitude and feature of cell-nanoparticle interactions.
Collapse
Affiliation(s)
- Angel Tan
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University (Parkville Campus), 3052 Victoria, Australia. and ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash University (Parkville Campus), 3052 Victoria, Australia
| | - Yuen Yi Lam
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University (Parkville Campus), 3052 Victoria, Australia. and ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash University (Parkville Campus), 3052 Victoria, Australia
| | - Olivier Pacot
- Institute of Systems Engineering, School of Engineering, University of Applied Sciences and Arts Western Switzerland, 1950 Sion, Switzerland
| | - Adrian Hawley
- Australian Synchrotron, ANSTO, 3168 Victoria, Australia
| | - Ben J Boyd
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University (Parkville Campus), 3052 Victoria, Australia. and ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash University (Parkville Campus), 3052 Victoria, Australia
| |
Collapse
|
27
|
Lee H, Na W, Lee BK, Lim CS, Shin S. Recent advances in microfluidic platelet function assays: Moving microfluidics into clinical applications. Clin Hemorheol Microcirc 2019; 71:249-266. [PMID: 30584134 DOI: 10.3233/ch-189416] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The analysis of platelet aggregation and thrombosis kinetics has significantly advanced with progress in microfluidic technology. However, the results of platelet aggregation tests do not fully reflect the observed clinical outcomes. To address the present unmet clinical needs, the basic but essential biology of platelets should be reconsidered in relation to the characteristics of microfluidic systems employed for platelet tests. To this end, the present article provides an overview of commercially available point of care devices and focuses on recent microfluidic studies, describing their measurement principles. We critically discuss the characteristics of the microfluidics systems used to evaluate the complex processes underlying platelet aggregation, and that are specifically designed to mimic the pathophysiological environment of blood vessels, including hemodynamic factors as well as blood vessel injury. To this end, we summarize unsolved issues related to the application of platelet function tests based on microfluidics. Overall, we confirm that platelet function tests based on microfluidics provide a versatile platform that encompasses a variety of basic research, as well as clinical diagnostic applications.
Collapse
Affiliation(s)
- Hoyoon Lee
- Department of Mechanical Engineering, Korea University, Seoul, Korea
| | - Wonwhi Na
- Engineering Research Center for Biofluid Biopsy, Korea University, Seoul, Korea
| | - Byoung-Kwon Lee
- Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University Medical College, Seoul, Korea
| | - Chae-Seung Lim
- Department of Laboratory Medicine, Guro Hospital, Korea University, Seoul, Korea
| | - Sehyun Shin
- Department of Mechanical Engineering, Korea University, Seoul, Korea.,Engineering Research Center for Biofluid Biopsy, Korea University, Seoul, Korea
| |
Collapse
|
28
|
Microclot array elastometry for integrated measurement of thrombus formation and clot biomechanics under fluid shear. Nat Commun 2019; 10:2051. [PMID: 31053712 PMCID: PMC6499828 DOI: 10.1038/s41467-019-10067-6] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Accepted: 04/15/2019] [Indexed: 11/08/2022] Open
Abstract
Blood clotting at the vascular injury site is a complex process that involves platelet adhesion and clot stiffening/contraction in the milieu of fluid flow. An integrated understanding of the hemodynamics and tissue mechanics regulating this process is currently lacking due to the absence of an experimental system that can simultaneously model clot formation and measure clot mechanics under shear flow. Here we develop a microfluidic-integrated microclot-array-elastometry system (clotMAT) that recapitulates dynamic changes in clot mechanics under physiological shear. Treatments with procoagulants and platelet antagonists and studies with diseased patient plasma demonstrate the ability of the system to assay clot biomechanics associated with common antiplatelet treatments and bleeding disorders. The changes of clot mechanics under biochemical treatments and shear flow demonstrate independent yet equally strong effects of these two stimulants on clot stiffening. This microtissue force sensing system may have future research and diagnostic potential for various bleeding disorders.
Collapse
|
29
|
Liao WJ, Wu MY, Peng CC, Tung YC, Yang RB. Epidermal growth factor-like repeats of SCUBE1 derived from platelets are critical for thrombus formation. Cardiovasc Res 2019; 116:193-201. [DOI: 10.1093/cvr/cvz036] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Revised: 01/16/2019] [Accepted: 02/04/2019] [Indexed: 11/13/2022] Open
Abstract
Abstract
Aims
SCUBE1 [signal peptide-CUB-epidermal growth factor (EGF) domain-containing protein 1], expressed in endothelial cells (ECs) and platelets, exists in soluble or membrane forms. We previously showed that soluble SCUBE1 is a biomarker for platelet activation and also an active participant of thrombosis. However, whether the adhesive module of its EGF-like repeats is essential and the specific contribution of SCUBE1 synthesized in ECs or platelets to thrombosis in vivo remain unclear.
Methods and results
We generated new mutant (Δ2) mice lacking the entire EGF-like repeats to evaluate the module’s functional importance during thrombogenesis in vivo. The Δ2 platelet-rich plasma showed markedly impaired platelet aggregation induced by agonists including adenosine diphosphate, collagen, the thrombin agonist PAR-4 peptide and the thromboxane A2 analogue U46619. Consistently, genetic ablation of the EGF-like repeats diminished arterial thrombosis and protected Δ2 mice against lethal thromboembolism. On flow chamber assay, whole blood isolated from Δ2 or wild-type (WT) mice pre-treated with blocking antibodies against the EGF-like repeats showed a significant decrease in platelet deposition and thrombus formation on collagen-coated surfaces under arterial shear rates. Moreover, we created animals expressing SCUBE1 only in ECs (S1-EC) or platelets (S1-PLT) by reciprocal bone-marrow transplantation between WT and Δ2 mice. The time of carotid arterial thrombosis induced by ferric chloride was normal in S1-PLT chimeric mice but much prolonged in S1-EC animals.
Conclusions
We demonstrate that platelet-derived SCUBE1 plays a critical role in arterial thrombosis via its adhesive EGF-like repeats in vivo and suggest targeting these adhesive motifs of SCUBE1 for potential anti-thrombotic strategy.
Collapse
Affiliation(s)
- Wei-Ju Liao
- Institute of Biomedical Sciences, Academia Sinica, 128 Academia Road, Sec. 2, Taipei 11529, Taiwan
| | - Meng-Ying Wu
- Institute of Biomedical Sciences, Academia Sinica, 128 Academia Road, Sec. 2, Taipei 11529, Taiwan
| | - Chen-Chung Peng
- Research Center for Applied Sciences, 128 Academia Road, Sec. 2, Taipei 11529, Taiwan
| | - Yi-Chung Tung
- Research Center for Applied Sciences, 128 Academia Road, Sec. 2, Taipei 11529, Taiwan
| | - Ruey-Bing Yang
- Institute of Biomedical Sciences, Academia Sinica, 128 Academia Road, Sec. 2, Taipei 11529, Taiwan
- Institute of Pharmacology, School of Medicine, National Yang-Ming University, 155 Linong Street, Sec. 2, Taipei 11221, Taiwan
- Ph.D. Program in Biotechnology Research and Development, College of Pharmacy, Taipei Medical University, 250 Wuxing Street, Taipei 11031, Taiwan
| |
Collapse
|
30
|
Hanke J, Ranke C, Perego E, Köster S. Human blood platelets contract in perpendicular direction to shear flow. SOFT MATTER 2019; 15:2009-2019. [PMID: 30724316 DOI: 10.1039/c8sm02136h] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In their physiological environment, blood platelets are permanently exposed to shear forces caused by blood flow. Within this surrounding, they generate contractile forces that eventually lead to a compaction of the blood clot. Here, we present a microfluidic chamber that combines hydrogel-based traction force microscopy with a controlled shear environment, and investigate the force fields platelets generate when exposed to shear flow in a spatio-temporally resolved manner. We find that for shear rates between 14 s-1 to 33 s-1, the general contraction behavior in terms of force distribution and magnitude does not differ from no-flow conditions. The main direction of contraction, however, does respond to the externally applied stress. At high shear stress, we observe an angle of about 90° between flow direction and main contraction axis. We explain this observation by the distribution of the stress acting on the adherent cell: the observed angle provides the most stable situation for the cell experiencing the shear flow, as supported by a finite element method simulation of the stresses along the platelet boundary.
Collapse
Affiliation(s)
- Jana Hanke
- Institute for X-Ray Physics, University of Goettingen, 37077 Göttingen, Germany.
| | | | | | | |
Collapse
|
31
|
Lordkipanidzé M, Hvas AM, Harrison P. Clinical Tests of Platelet Function. Platelets 2019. [DOI: 10.1016/b978-0-12-813456-6.00033-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
32
|
Dimasi A, Roka-Moiia Y, Consolo F, Rasponi M, Fiore GB, Slepian MJ, Redaelli A. Microfluidic flow-based platforms for induction and analysis of dynamic shear-mediated platelet activation-Initial validation versus the standardized hemodynamic shearing device. BIOMICROFLUIDICS 2018; 12:042208. [PMID: 29861819 PMCID: PMC5963949 DOI: 10.1063/1.5024500] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Accepted: 05/07/2018] [Indexed: 06/08/2023]
Abstract
A microfluidic flow-based platform (μFP), able to stimulate platelets via exposure of shear stress patterns pertinent to cardiovascular devices and prostheses, was compared to the Hemodynamic Shearing Device (HSD)-a state-of-the-art bench-top system for exposure of platelets to defined levels and patterns of shear. Platelets were exposed to time-varying shear stress patterns in the two systems; in detail, platelets were recirculated in the μFP or stimulated in the HSD to replicate comparable exposure time. Shear-mediated platelet activation was evaluated via (i) the platelet activity state assay, allowing the measurement of platelet-mediated thrombin generation and associated prothrombotic tendencies, (ii) scanning electron microscopy to evaluate morphological changes of sheared platelets, and (iii) flow cytometry for the determination of platelet phosphatidylserine exposure as a marker of shear activation. The results revealed good matching and comparability between the two systems, with similar trends of platelet activation, formation of microaggregates, and analogous trends of activation marker exposure for both the HSD and microfluidic-stimulated samples. These findings support future translation of the microfluidic platform as a Point-of-Care facsimile system for the diagnosis of thrombotic risk in patients implanted with cardiovascular devices.
Collapse
Affiliation(s)
- Annalisa Dimasi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Golgi 39, 20133 Milano, Italy
| | - Yana Roka-Moiia
- Department of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, 1501 N Campbell Ave, Tucson, Arizona 85724, USA
| | | | - Marco Rasponi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Golgi 39, 20133 Milano, Italy
| | - Gianfranco B. Fiore
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Golgi 39, 20133 Milano, Italy
| | - Marvin J Slepian
- Department of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, 1501 N Campbell Ave, Tucson, Arizona 85724, USA
| | - Alberto Redaelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Golgi 39, 20133 Milano, Italy
| |
Collapse
|
33
|
Zavrel EA, Shen X. TOWARD A MICROFLUIDIC IMPLEMENTATION OF A DIGITAL POTENTIOMETER. PROCEEDINGS OF THE ... DESIGN OF MEDICAL DEVICES CONFERENCE. DESIGN OF MEDICAL DEVICES CONFERENCE 2018; 2018:V001T05A002. [PMID: 30854172 PMCID: PMC6407897 DOI: 10.1115/dmd2018-6812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Herein, we report on the motivation for, design of, and progress toward a microfluidic implementation of a digital potentiometer for various physical and life science applications.
Collapse
Affiliation(s)
- Erik A Zavrel
- Department of Biomedical Engineering Cornell University, Ithaca, NY, United States
| | - Xiling Shen
- Department of Biomedical Engineering Duke University, Durham, NC, United States
| |
Collapse
|
34
|
Fabricating smooth PDMS microfluidic channels from low-resolution 3D printed molds using an omniphobic lubricant-infused coating. Anal Chim Acta 2018; 1000:248-255. [DOI: 10.1016/j.aca.2017.11.063] [Citation(s) in RCA: 73] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Revised: 11/23/2017] [Accepted: 11/24/2017] [Indexed: 11/17/2022]
|
35
|
Plegue TJ, Kovach KM, Thompson AJ, Potkay JA. Stability of Polyethylene Glycol and Zwitterionic Surface Modifications in PDMS Microfluidic Flow Chambers. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2018; 34:492-502. [PMID: 29231737 DOI: 10.1021/acs.langmuir.7b03095] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Blood-material interactions are crucial to the lifetime, safety, and overall success of blood contacting devices. Hydrophilic polymer coatings have been employed to improve device lifetime by shielding blood contacting materials from the natural foreign body response, primarily the intrinsic pathway of the coagulation cascade. These coatings have the ability to repel proteins, cells, bacteria, and other micro-organisms. Coatings are desired to have long-term stability, so that the nonthrombogenic and nonfouling effects gained are long lasting. Unfortunately, there exist limited studies which investigate their stability under dynamic flow conditions as encountered in a physiological setting. In addition, direct comparisons between multiple coatings are lacking in the literature. In this study, we investigate the stability of polyethylene glycol (PEG), zwitterionic sulfobetaine silane (SBSi), and zwitterionic polyethylene glycol sulfobetaine silane (PEG-SBSi) grafted by a room temperature, sequential flow chemistry process on polydimethylsiloxane (PDMS) over time under ambient, static fluid (no flow), and physiologically relevant flow conditions and compare the results to uncoated PDMS controls. PEG, SBSi, and PEG-SBSi coatings maintained contact angles below 20° for up to 35 days under ambient conditions. SBSi and PEG-SBSi showed increased stability and hydrophilicity after 7 days under static conditions. They also retained contact angles ≤40° for all shear rates after 7 days under flow, demonstrating their potential for long-term stability. The effectiveness of the coatings to resist platelet adhesion was also studied under physiological flow conditions. PEG showed a 69% reduction in adhered platelets, PEG-SBSi a significant 80% reduction, and SBSi a significant 96% reduction compared to uncoated control samples, demonstrating their potential applicability for blood contacting applications. In addition, the presented coatings and their stability under shear may be of interest in other applications including marine coatings, lab on a chip devices, and contact lenses, where it is desirable to reduce surface fouling due to proteins, cells, and other organisms.
Collapse
Affiliation(s)
- Thomas J Plegue
- VA Ann Arbor Healthcare System , Ann Arbor, Michigan 48105, United States
| | - Kyle M Kovach
- Department of Biomedical Engineering, Case Western Reserve University , Cleveland, Ohio 44106, United States
| | - Alex J Thompson
- VA Ann Arbor Healthcare System , Ann Arbor, Michigan 48105, United States
- Department of Surgery, University of Michigan , Ann Arbor, Michigan 48109, United States
| | - Joseph A Potkay
- VA Ann Arbor Healthcare System , Ann Arbor, Michigan 48105, United States
- Department of Surgery, University of Michigan , Ann Arbor, Michigan 48109, United States
| |
Collapse
|
36
|
Ciciliano JC, Abbaspour R, Woodall J, Wu C, Bakir MS, Lam WA. Probing blood cell mechanics of hematologic processes at the single micron level. LAB ON A CHIP 2017; 17:3804-3816. [PMID: 29052682 DOI: 10.1039/c7lc00720e] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Blood cells circulate in a dynamic fluidic environment, and during hematologic processes such as hemostasis, thrombosis, and inflammation, blood cells interact biophysically with a myriad of vascular matrices-blood clots and the subendothelial matrix. While it is known that adherent cells physiologically respond to the mechanical properties of their underlying matrices, how blood cells interact with their mechanical microenvironment of vascular matrices remains poorly understood. To that end, we developed microfluidic systems that achieve high fidelity, high resolution, single-micron PDMS features that mimic the physical geometries of vascular matrices. With these electron beam lithography (EBL)-based microsystems, the physical interactions of individual blood cells with the mechanical properties of the matrices can be directly visualized. We observe that the physical presence of the matrix, in and of itself, mediates hematologic processes of the three major blood cell types: platelets, erythrocytes, and leukocytes. First, we find that the physical presence of single micron micropillars creates a shear microgradient that is sufficient to cause rapid, localized platelet adhesion and aggregation that leads to complete microchannel occlusion; this response is enhanced with the presence of fibrinogen or collagen on the micropillar surface. Second, we begin to describe the heretofore unknown biophysical parameters for the formation of schistocytes, pathologic erythrocyte fragments associated with various thrombotic microangiopathies (poorly understood, yet life-threatening blood disorders associated with microvascular thrombosis). Finally, we observe that the physical interactions with a vascular matrix is sufficient to cause neutrophils to form procoagulant neutrophil extracellular trap (NET)-like structures. By combining electron beam lithography (EBL), photolithography, and soft lithography, we thus create microfluidic devices that provide novel insight into the response of blood cells to the mechanical microenvironment of vascular matrices and have promise as research-enabling and diagnostic platforms.
Collapse
Affiliation(s)
- Jordan C Ciciliano
- Woodruff School of Mechanical Engineering, Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA, USA
| | | | | | | | | | | |
Collapse
|
37
|
Adding dimension to cellular mechanotransduction: Advances in biomedical engineering of multiaxial cell-stretch systems and their application to cardiovascular biomechanics and mechano-signaling. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2017. [DOI: 10.1016/j.pbiomolbio.2017.06.011] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
38
|
Islam MM, Beverung S, Steward R. Bio-Inspired Microdevices that Mimic the Human Vasculature. MICROMACHINES 2017; 8:mi8100299. [PMID: 30400489 PMCID: PMC6190335 DOI: 10.3390/mi8100299] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Revised: 09/25/2017] [Accepted: 09/26/2017] [Indexed: 12/17/2022]
Abstract
Blood vessels may be found throughout the entire body and their importance to human life is undeniable. This is evident in the fact that a malfunctioning blood vessel can result in mild symptoms such as shortness of breath or chest pain to more severe symptoms such as a heart attack or stroke, to even death in the severest of cases. Furthermore, there are a host of pathologies that have been linked to the human vasculature. As a result many researchers have attempted to unlock the mysteries of the vasculature by performing studies that duplicate the physiological structural, chemical, and mechanical properties known to exist. While the ideal study would consist of utilizing living, blood vessels derived from human tissue, such studies are not always possible since intact human blood vessels are not readily accessible and there are immense technical difficulties associated with such studies. These limitations have opened the door for the development of microdevices modeled after the human vasculature as it is believed by many researchers in the field that such devices can one day replace tissue models. In this review we present an overview of microdevices developed to mimic various types of vasculature found throughout the human body. Although the human body contains a diverse array of vascular systems for this review we limit our discussion to the cardiovascular system and cerebrovascular system and discuss such systems that have been fabricated in both 2D and 3D configurations.
Collapse
Affiliation(s)
- Md Mydul Islam
- Department of Mechanical and Aerospace Engineering, University of Central Florida, Orlando, FL 32816, USA.
| | - Sean Beverung
- Department of Mechanical and Aerospace Engineering, University of Central Florida, Orlando, FL 32816, USA.
| | - Robert Steward
- Departments of Mechanical and Aerospace Engineering, College of Medicine, Burnett School of Biomedical Sciences, University of Central Florida, Orlando, FL 32816, USA.
| |
Collapse
|
39
|
Dimasi A, Rasponi M, Consolo F, Fiore GB, Bluestein D, Slepian MJ, Redaelli A. Microfludic platforms for the evaluation of anti-platelet agent efficacy under hyper-shear conditions associated with ventricular assist devices. Med Eng Phys 2017; 48:31-38. [PMID: 28869117 PMCID: PMC5610105 DOI: 10.1016/j.medengphy.2017.08.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2017] [Revised: 07/31/2017] [Accepted: 08/09/2017] [Indexed: 01/06/2023]
Abstract
Thrombus formation is a major adverse event affecting patients implanted with ventricular assist devices (VADs). Despite anti-thrombotic drug administration, thrombotic events remain frequent within the first year post-implantation. Platelet activation (PA) is an essential process underling thrombotic adverse events in VAD systems. Indeed, abnormal shear forces, correlating with specific flow trajectories of VADs, are strong agonists mediating PA. To date, the ability to determine efficacy of anti-platelet (AP) agents under shear stress conditions is limited. Here, we present a novel microfluidic platform designed to replicate shear stress patterns of a clinical VAD, and use it to compare the efficacy of two AP agents in vitro. Gel-filtered platelets were incubated with i) acetylsalicylic acid (ASA) and ii) ticagrelor, at two different concentrations (ASA: 125 and 250 µM; ticagrelor: 250 and 500 nM) and were circulated in the VAD-emulating microfluidic platform using a peristaltic pump. GFP was collected after 4 and 52 repetitions of exposure to the VAD shear pattern and tested for shear-mediated PA. ASA significantly inhibited PA only at 2-fold higher concentration (250 µM) than therapeutic dose (125 µM). The effect of ticagrelor was not dependent on drug concentration, and did not show significant inhibition with respect to untreated control. This study demonstrates the potential use of microfluidic platforms as means of testing platelet responsiveness and AP drug efficacy under complex and realistic VAD-like shear stress conditions.
Collapse
Affiliation(s)
- Annalisa Dimasi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Golgi 39, 20133, Milano, Italy.
| | - Marco Rasponi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Golgi 39, 20133, Milano, Italy
| | - Filippo Consolo
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Golgi 39, 20133, Milano, Italy; Anesthesia and Cardiothoracic Intensive Care Unit. Università Vita Salute, San Raffaele Scientific Institute, Via Olgettina 58, 20132, Milano, Italy
| | - Gianfranco B Fiore
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Golgi 39, 20133, Milano, Italy
| | - Danny Bluestein
- Department of Biomedical Engineering, StonyBrook University, Stony Brook, NY, USA
| | - Marvin J Slepian
- Department of Biomedical Engineering, StonyBrook University, Stony Brook, NY, USA; Department of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, 1501 N Campbell Ave, 85724, Tucson, AZ, USA
| | - Alberto Redaelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Golgi 39, 20133, Milano, Italy
| |
Collapse
|
40
|
Schoeman RM, Lehmann M, Neeves KB. Flow chamber and microfluidic approaches for measuring thrombus formation in genetic bleeding disorders. Platelets 2017; 28:463-471. [PMID: 28532218 PMCID: PMC6131111 DOI: 10.1080/09537104.2017.1306042] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Platelet adhesion and aggregation, coagulation, fibrin formation, and fibrinolysis are regulated by the forces and flows imposed by blood at the site of a vascular injury. Flow chambers designed to observe these events are an indispensable part of doing hemostasis and thrombosis research, especially with human blood. Microfluidic methods have provided the flexibility to design flow chambers with complex geometries and features that more closely mimic the anatomy and physiology of blood vessels. Additionally, microfluidic systems with integrated optics and/or pressure sensors and on-board signal processing could transform what have been primarily research tools into clinical assays. Here, we describe a historical review of how flow-based approaches have informed biophysical mechanisms in genetic bleeding disorders, challenges and potential solutions for developing models of bleeding in vitro, and outstanding issues that need to be addressed prior to their use in clinical settings.
Collapse
Affiliation(s)
- Rogier M. Schoeman
- Chemical and Biological Engineering Department, Colorado School of Mines, Golden, CO, USA
| | - Marcus Lehmann
- Chemical and Biological Engineering Department, Colorado School of Mines, Golden, CO, USA
| | - Keith B. Neeves
- Chemical and Biological Engineering Department, Colorado School of Mines, Golden, CO, USA
- Pediatrics, University of Colorado, Denver, CO, USA
| |
Collapse
|
41
|
Zhang C, Neelamegham S. Application of microfluidic devices in studies of thrombosis and hemostasis. Platelets 2017; 28:434-440. [PMID: 28580870 DOI: 10.1080/09537104.2017.1319047] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Due to the importance of fluid flow during thrombotic episodes, it is quite appropriate to study clotting and bleeding processes in devices that have well-defined fluid shear environments. Two common devices for applying these defined shear stresses include the cone-and-plate viscometer and parallel-plate flow chamber. While such tools have many salient features, they require large amounts of blood or other protein components. With growth in the area of microfluidics over the last two decades, it has become feasible to miniaturize such flow devices. Such miniaturization not only enables saving of precious samples but also increases the throughput of fluid shear devices, thus enabling the design of combinatorial experiments and making the technique more accessible to the larger scientific community. In addition to simple flows that are common in traditional flow apparatus, more complex geometries that mimic stenosed arteries and the human microvasculature can also be generated. The composition of the microfluidics cell substrate can also be varied for diverse basic science investigations, and clinical investigations that aim to assay either individual patient coagulopathy or response to anti-coagulation treatment. This review summarizes the current state of the art for such microfluidic devices and their applications in the field of thrombosis and hemostasis.
Collapse
Affiliation(s)
- Changjie Zhang
- a Chemical and Biological Engineering, and Clinical & Translational Research Center , University at Buffalo, State University of New York , Buffalo , NY , USA
| | - Sriram Neelamegham
- a Chemical and Biological Engineering, and Clinical & Translational Research Center , University at Buffalo, State University of New York , Buffalo , NY , USA
| |
Collapse
|
42
|
Six KR, Devloo R, Van Aelst B, Vandekerckhove P, Feys HB, Compernolle V. A Microfluidic Flow Chamber Model for Platelet Transfusion and Hemostasis Measures Platelet Deposition and Fibrin Formation in Real-time. J Vis Exp 2017. [PMID: 28287584 PMCID: PMC5409263 DOI: 10.3791/55351] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Microfluidic models of hemostasis assess platelet function under conditions of hydrodynamic shear, but in the presence of anticoagulants, this analysis is restricted to platelet deposition only. The intricate relationship between Ca2+-dependent coagulation and platelet function requires careful and controlled recalcification of blood prior to analysis. Our setup uses a Y-shaped mixing channel, which supplies concentrated Ca2+/Mg2+ buffer to flowing blood just prior to perfusion, enabling rapid recalcification without sample stasis. A ten-fold difference in flow velocity between both reservoirs minimizes dilution. The recalcified blood is then perfused in a collagen-coated analysis chamber, and differential labeling permits real-time imaging of both platelet and fibrin deposition using fluorescence video microscopy. The system uses only commercially available tools, increasing the chances of standardization. Reconstitution of thrombocytopenic blood with platelets from banked concentrates furthermore models platelet transfusion, proving its use in this research domain. Exemplary data demonstrated that coagulation onset and fibrin deposition were linearly dependent on the platelet concentration, confirming the relationship between primary and secondary hemostasis in our model. In a timeframe of 16 perfusion min, contact activation did not take place, despite recalcification to normal Ca2+ and Mg2+ levels. When coagulation factor XIIa was inhibited by corn trypsin inhibitor, this time frame was even longer, indicating a considerable dynamic range in which the changes in the procoagulant nature of the platelets can be assessed. Co-immobilization of tissue factor with collagen significantly reduced the time to onset of coagulation, but not its rate. The option to study the tissue factor and/or the contact pathway increases the versatility and utility of the assay.
Collapse
Affiliation(s)
- Katrijn R Six
- Transfusion Research Center, Belgian Red Cross-Flanders; Faculty of Medicine and Health Sciences, Ghent University
| | | | | | - Philippe Vandekerckhove
- Faculty of Medicine and Health Sciences, Ghent University; Blood Service, Belgian Red Cross-Flanders; Department of Public Health and Primary Care, KULeuven - University of Leuven
| | - Hendrik B Feys
- Transfusion Research Center, Belgian Red Cross-Flanders;
| | - Veerle Compernolle
- Transfusion Research Center, Belgian Red Cross-Flanders; Faculty of Medicine and Health Sciences, Ghent University; Blood Service, Belgian Red Cross-Flanders
| |
Collapse
|
43
|
Lee H, Kim G, Lim C, Lee B, Shin S. A simple method for activating the platelets used in microfluidic platelet aggregation tests: Stirring-induced platelet activation. BIOMICROFLUIDICS 2016; 10:064118. [PMID: 28058084 PMCID: PMC5176351 DOI: 10.1063/1.4972077] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Accepted: 11/29/2016] [Indexed: 06/06/2023]
Abstract
High-shear stimulation is well known as one of the key factors affecting platelet activation and aggregation, which can lead to the formation of a thrombus. In one of our previous studies, we introduced migration distance-based platelet function analysis in a microfluidic system. In this study, we set out to examine the effects of stirring on shear-induced platelet activation and aggregation in a chamber system by using a rotating stirrer. We found that the rotating stirrer caused not only rotational shear flow but also a strong radial secondary flow. The latter flow led to efficient mixing in the chamber. Moreover, the rotational flow led to the generation of shear stress, the magnitude of which can be controlled to activate the platelets. Activated platelets tend to aggregate themselves. The maximum platelet aggregation was observed at a critical shear rate of 3100 s-1, regardless of the stirrer shape. Furthermore, the time taken to attain maximum aggregation was significantly shortened when using a wide stirrer (30 s) instead of a narrow one (180 s). When using a flat stirrer, the non-uniform shear field in the chamber system was resolved with the radial secondary flow-induced mixing; thus, most of the platelets were homogenously activated. The stirring-induced platelet activation mechanism was experimentally confirmed in a microfluidic system for a platelet aggregation test while monitoring the migration distance until the microfluidic channel is occluded. Our findings indicate that the present system, consisting of a rotating stirrer and a confined chamber, provides effective shear stimulation for activating platelets and inducing platelet aggregates.
Collapse
Affiliation(s)
- Hoyoon Lee
- School of Mechanical Engineering, Korea University , Seoul 136-701, South Korea
| | - Gyehyu Kim
- School of Mechanical Engineering, Korea University , Seoul 136-701, South Korea
| | - Chaeseung Lim
- Department of Laboratory Medicine, College of Medicine, Korea University Guro Hospital , Seoul 152-703, South Korea
| | - ByoungKwon Lee
- Department of Internal Medicine, College of Medicine, Yonsei University Gangnam Severance Hospital , Seoul 135-720, South Korea
| | - Sehyun Shin
- School of Mechanical Engineering, Korea University , Seoul 136-701, South Korea
| |
Collapse
|
44
|
Reviakine I, Jung F, Braune S, Brash JL, Latour R, Gorbet M, van Oeveren W. Stirred, shaken, or stagnant: What goes on at the blood-biomaterial interface. Blood Rev 2016; 31:11-21. [PMID: 27478147 DOI: 10.1016/j.blre.2016.07.003] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Revised: 07/08/2016] [Accepted: 07/12/2016] [Indexed: 01/15/2023]
Abstract
There is a widely recognized need to improve the performance of vascular implants and external medical devices that come into contact with blood by reducing adverse reactions they cause, such as thrombosis and inflammation. These reactions lead to major adverse cardiovascular events such as heart attacks and strokes. Currently, they are managed therapeutically. This need remains unmet by the biomaterials research community. Recognized stagnation of the blood-biomaterial interface research translates into waning interest from clinicians, funding agencies, and practitioners of adjacent fields. The purpose of this contribution is to stir things up. It follows the 2014 BloodSurf meeting (74th International IUVSTA Workshop on Blood-Biomaterial Interactions), offers reflections on the situation in the field, and a three-pronged strategy integrating different perspectives on the biological mechanisms underlying blood-biomaterial interactions. The success of this strategy depends on reengaging clinicians and on the renewed cooperation of the funding agencies to support long-term efforts.
Collapse
Affiliation(s)
- Ilya Reviakine
- Institute of Functional Interfaces (IFG), Karlsruhe Institute of Technology (KIT), Hermann von Helmholtz Platz 1, 76344 Eggenstein-Leopoldshafen, Germany; Department of Bioengineering, University of Washington, Seattle, WA 98105, USA.
| | - Friedrich Jung
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies (BCRT), Helmholtz Zentrum Geesthacht, Kantstrasse 55, 14513 Teltow, Germany
| | - Steffen Braune
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies (BCRT), Helmholtz Zentrum Geesthacht, Kantstrasse 55, 14513 Teltow, Germany
| | - John L Brash
- Department of Chemical Engineering, School of Biomedical Engineering, McMaster University, Hamilton, Ontario, L8S 4L8, Canada
| | - Robert Latour
- Rhodes Engineering Research Center, Department of Bioengineering, Clemson University, Clemson, SC 29634, USA
| | - Maud Gorbet
- Department of Systems Design Engineering, Biomedical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada
| | - Wim van Oeveren
- HaemoScan, Stavangerweg 23-23, 9723JC Groningen, The Netherlands
| |
Collapse
|
45
|
Eichinger CD, Fogelson AL, Hlady V. Functional assay of antiplatelet drugs based on margination of platelets in flowing blood. Biointerphases 2016; 11:029805. [PMID: 27030476 PMCID: PMC4818277 DOI: 10.1116/1.4945305] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2016] [Revised: 03/18/2016] [Accepted: 03/22/2016] [Indexed: 02/02/2023] Open
Abstract
A novel functional assay of antiplatelet drug efficacy was designed by utilizing the phenomena of platelet margination in flowing blood and transient platelet contacts with surface-immobilized platelet agonists. Flow margination enhances transient contacts of platelets with the walls of flow chambers covered with surface-immobilized proteins. Depending on the type and the surface density of the immobilized agonists, such transient interactions could "prime" the marginated platelet subpopulation for enhanced activation and adhesion downstream. By creating an upstream surface patch with an immobilized platelet agonist, platelet flow margination was used to test how effective antiplatelet drugs are in suppressing downstream platelet activation and adhesion. The platelet adhesion downstream was measured by a so-called "capture" patch region close to the distal end of the flow chamber. Platelet adhesion downstream was found to be dose-dependent on the upstream surface coverage of the "priming" patch, with immobilized fibrinogen acting as a platelet agonist. Several antiplatelet agents (acetylsalicylic acid, eptifibatide, and tirofiban) were evaluated for their efficacy in attenuating downstream adhesion after upstream platelet priming. The activation of the platelet population was found to be dependent on both the extent of the upstream agonist stimulus and the antiplatelet drug concentration. Such a relationship provides an opportunity to measure the efficacy of specific antiplatelet agents against the type and concentration of upstream platelet agonists.
Collapse
Affiliation(s)
- Colin D Eichinger
- Department of Bioengineering, University of Utah, Salt Lake City, Utah 84112
| | - Aaron L Fogelson
- Department of Mathematics, University of Utah, Salt Lake City, Utah 84112
| | - Vladimir Hlady
- Department of Bioengineering, University of Utah, Salt Lake City, Utah 84112
| |
Collapse
|
46
|
Microfluidic approaches for the assessment of blood cell trauma: a focus on thrombotic risk in mechanical circulatory support devices. Int J Artif Organs 2016; 39:184-93. [PMID: 27034318 DOI: 10.5301/ijao.5000485] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/03/2016] [Indexed: 11/20/2022]
Abstract
INTRODUCTION Mechanical circulatory support devices (MCSDs) are emerging as a valuable therapeutic option for the management of end-stage heart failure. However, although recipients are routinely administered with anti-thrombotic (AT) drugs, thrombosis persists as a severe post-implant complication. Conventional clinical assays and coagulation markers demonstrate partial ability in preventing the onset of thrombosis. Through years, different laboratory techniques have been proposed as potential tools for the evaluation of platelets' hemostatic response in MCSD recipients. Most rely on platelet aggregation tests; they are performed in static or low shear conditions, neglecting the prominent contribution of MCSD shear-induced mechanical load in enhancing platelet activation (PA). On the other hand, those tests able to account for shear-induced PA have limited possibility of effective clinical translation. AIMS AND METHODS Advances on this side have been addressed by microfluidic technology. Microfluidic devices have been developed for AT drug monitoring under flow, able to replicate physiological and/or constant shear flow conditions in vitro. In this paper, we present a newly developed microfluidic platform able to expose platelets to MCSD-specific dynamic shear stress patterns. We performed in vitro tests circulating human platelets in the microfluidic platform and quantifying the dynamics of PA by means of the Platelet Activity State (PAS) assay. RESULTS Our results prove the feasibility of using microfluidics for the diagnosis of MCSD-related thrombotic risk. This study paves the way for the development of a miniaturized point-of-care device for monitoring AT drug regimen. Such a system may have significant impact on limiting the incidence of thrombosis in MCSD recipients.
Collapse
|
47
|
Dimasi A, Rasponi M, Sheriff J, Chiu WC, Bluestein D, Tran PL, Slepian MJ, Redaelli A. Microfluidic emulation of mechanical circulatory support device shear-mediated platelet activation. Biomed Microdevices 2015; 17:117. [PMID: 26578003 PMCID: PMC4855287 DOI: 10.1007/s10544-015-0015-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Thrombosis of ventricular assist devices (VADs) compromises their performance, with associated risks of systemic embolization, stroke, pump stop and possible death. Anti-thrombotic (AT) drugs, utilized to limit thrombosis, are largely dosed empirically, with limited testing of their efficacy. Further, such testing, if performed, typically examines efficacy under static conditions, which is not reflective of actual shear-mediated flow. Here we adopted our previously developed Device Thrombogenicity Emulation methodology to design microfluidic platforms able to emulate representative shear stress profiles of mechanical circulatory support (MCS) devices. Our long-term goal is to utilize these systems for point-of-care (POC) personalized testing of AT efficacy under specific, individual shear profiles. First, we designed different types of microfluidic channels able to replicate sample shear stress patterns observed in MCS devices. Second, we explored the flexibility of microfluidic technology in generating dynamic shear stress profiles by modulating the geometrical features of the channels. Finally, we designed microfluidic channel systems able to emulate the shear stress profiles of two commercial VADs. From CFD analyses, the VAD-emulating microfluidic systems were able to replicate the main characteristics of the shear stress waveforms of the macroscale VADs (i.e., shear stress peaks and duration). Our results establish the basis for development of a lab-on-chip POC system able to perform device-specific and patient-specific platelet activation state assays.
Collapse
Affiliation(s)
- Annalisa Dimasi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, 20133, Italy
| | - Marco Rasponi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, 20133, Italy
| | - Jawaad Sheriff
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA
| | - Wei-Che Chiu
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA
| | - Phat L Tran
- Department of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, 1501 North Campbell Avenue, Tucson, AZ, 85724, USA
| | - Marvin J Slepian
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA.
- Department of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, 1501 North Campbell Avenue, Tucson, AZ, 85724, USA.
| | - Alberto Redaelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, 20133, Italy
| |
Collapse
|
48
|
Yang L, Okamura Y, Kimura H. Surface modification on polydimethylsiloxane-based microchannels with fragmented poly(l-lactic acid) nanosheets. BIOMICROFLUIDICS 2015; 9:064108. [PMID: 26634016 PMCID: PMC4654732 DOI: 10.1063/1.4936350] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2015] [Accepted: 11/11/2015] [Indexed: 05/08/2023]
Abstract
Surface modification is a critical issue in various applications of polydimethylsiloxane (PDMS)-based microfluidic devices. Here, we describe a novel method through which PDMS-based microchannels were successfully modified with fragmented poly(l-lactic acid) (PLLA) nanosheets through a simple patchwork technique that exploited the high level of adhesiveness of PLLA nanosheets. Compared with other surface modification methods, our method required neither complicated chemical modifications nor the use of organic solvents that tend to cause PDMS swelling. The experimental results indicated that the modified PDMS exhibited excellent capacity for preventing the adhesion and activation of platelets. This simple yet efficient method can be used to fabricate the special PDMS microfluidic devices for biological, medical, and even hematological purposes.
Collapse
Affiliation(s)
- Lu Yang
- Micro/Nano Technology Center, Tokai University , 4-1-1 Kitakaname, Hiratsuka, Kanagawa 259-1292, Japan
| | | | | |
Collapse
|
49
|
Combariza ME, Yu X, Nesbitt WS, Mitchell A, Tovar-Lopez FJ. Nonlinear Dynamic Modelling of Platelet Aggregation via Microfluidic Devices. IEEE Trans Biomed Eng 2015; 62:1718-27. [DOI: 10.1109/tbme.2015.2403266] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
50
|
Wang H, Liu J, Zheng X, Rong X, Zheng X, Peng H, Silber-Li Z, Li M, Liu L. Three-dimensional virtual surgery models for percutaneous coronary intervention (PCI) optimization strategies. Sci Rep 2015; 5:10945. [PMID: 26042609 PMCID: PMC4455241 DOI: 10.1038/srep10945] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2015] [Accepted: 05/11/2015] [Indexed: 12/03/2022] Open
Abstract
Percutaneous coronary intervention (PCI), especially coronary stent implantation, has been shown to be an effective treatment for coronary artery disease. However, in-stent restenosis is one of the longstanding unsolvable problems following PCI. Although stents implanted inside narrowed vessels recover normal flux of blood flows, they instantaneously change the wall shear stress (WSS) distribution on the vessel surface. Improper stent implantation positions bring high possibilities of restenosis as it enlarges the low WSS regions and subsequently stimulates more epithelial cell outgrowth on vessel walls. To optimize the stent position for lowering the risk of restenosis, we successfully established a digital three-dimensional (3-D) model based on a real clinical coronary artery and analysed the optimal stenting strategies by computational simulation. Via microfabrication and 3-D printing technology, the digital model was also converted into in vitro microfluidic models with 3-D micro channels. Simultaneously, physicians placed real stents inside them; i.e., they performed “virtual surgeries”. The hydrodynamic experimental results showed that the microfluidic models highly inosculated the simulations. Therefore, our study not only demonstrated that the half-cross stenting strategy could maximally reduce restenosis risks but also indicated that 3-D printing combined with clinical image reconstruction is a promising method for future angiocardiopathy research.
Collapse
Affiliation(s)
- Hujun Wang
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China.,Key Laboratory of Soft Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China
| | - Jinghua Liu
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart, Lung and Blood Vessel Disease, Beijing 100029, China
| | - Xu Zheng
- State key laboratory of Nonlinear Mechanics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China
| | - Xiaohui Rong
- Key Laboratory of Soft Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China
| | - Xuwei Zheng
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart, Lung and Blood Vessel Disease, Beijing 100029, China
| | - Hongyu Peng
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart, Lung and Blood Vessel Disease, Beijing 100029, China
| | - Zhanghua Silber-Li
- State key laboratory of Nonlinear Mechanics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China
| | - Mujun Li
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Liyu Liu
- Key Laboratory of Soft Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China
| |
Collapse
|