1
|
Hari Gupta G, Mohan K, Ghosh S, Sarath Babu S, Velyutham R, Kapusetti G. Label-Free detection of Poly-Cystic Ovarian Syndrome using a highly conductive 2-D rGO/MoS 2/PANI nanocomposite based immunosensor. Bioelectrochemistry 2024; 158:108681. [PMID: 38493574 DOI: 10.1016/j.bioelechem.2024.108681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 03/11/2024] [Accepted: 03/13/2024] [Indexed: 03/19/2024]
Abstract
Polycystic ovarian syndrome (PCOS) is an endocrinal disorder characterized by multiple tiny cysts, amenorrhea, dysmenorrhea, hirsutism, and infertility. The current diagnostic tools comprise of expensive, time-consuming ultrasonography to serological test, which have low patient compliance. To address these limitations, we have developed a highly sensitive, cost effective and ultrafast immunosensor for the diagnosis of PCOS. Herein, we have fabricated a 2-D electro conductive composites of reduced Graphene oxide (rGO), Molybdenum disulfide (MoS2), and Polyaniline (PANI) as electrode material. Furthermore, for detecting an early and non-cyclic biomarker of PCOS, i.e. anti-Mullerian hormone (AMH). We utilize the specific antigen-antibody mechanism, in which monoclonal Anti-AMH antibodies were covalently immobilized using EDC-NHS chemistry on electrode. The developed biosensor was physicochemical and electrochemically characterized to demonstrate its efficiency. Further we have investigated the biosensor's performance with Cyclic Voltammetry, Differential Pulse Voltammetry, and Electrochemical Impedance Spectroscopy. We have validated that under the optimized condition the immunosensor exhibits higher sensitivity with a LOD of ∼ 2.0 ng/mL with a linear range up to 100 ng/mL. Furthermore, this immunosensor works efficiently with a lower sample volume (>5 μL), which provides a sensitive, reproducible, low-cost, rapid analysis to detect AMH level in PCOS diagnosis.
Collapse
Affiliation(s)
- Gourang Hari Gupta
- Department of Medical Devices, National Institute of Pharmaceutical Education and Research (NIPER)- Ahmedabad, India
| | - Keerthana Mohan
- Department of Medical Devices, National Institute of Pharmaceutical Education and Research (NIPER)- Ahmedabad, India
| | - Sumanta Ghosh
- Department of Medical Devices, National Institute of Pharmaceutical Education and Research (NIPER)- Ahmedabad, India
| | | | | | - Govinda Kapusetti
- National Institute of Pharmaceutical Education and Research (NIPER), Kolkata, India; Department of Medical Devices, National Institute of Pharmaceutical Education and Research (NIPER)- Ahmedabad, India.
| |
Collapse
|
2
|
Masud, Aftabuzzaman M, Zhou H, Kim S, Yi J, Park SS, Kim YS, Kim HK. Chemically synthesized poly(3,4-ethylenedioxythiophene) conducting polymer as a robust electrocatalyst for highly efficient dye-sensitized solar cells. NANOSCALE 2024; 16:13874-13884. [PMID: 38990512 DOI: 10.1039/d4nr00949e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/12/2024]
Abstract
Chemically synthesized PEDOT (poly(3,4-ethylenedioxythiophene)) nanomaterials, with various nanostructured morphologies as well as different intrinsic electrical conductivities and crystallinities, were compared as electrocatalysts for Co(III) reduction in dye-sensitized solar cells (DSSCs). Electrochemical parameters, charge transfer resistance toward the electrode/electrolyte interface, catalytic activity for Co(III)-reduction, and diffusion of cobalt redox species greatly depend on the morphology, crystallinity, and intrinsic electrical conductivity of the chemically synthesized PEDOTs and optimization of the fabrication procedure for counter electrodes. The PEDOT counter electrode, fabricated by spin coating a DMSO-dispersed PEDOT solution with an ordered 1D structure and nanosized fibers averaging 70 nm in diameter and an electrical conductivity of ∼16 S cm-1, exhibits the lowest charge transfer resistance, highest diffusion for a cobalt redox mediator and superior electrocatalytic performance compared to a traditional Pt-counter electrode. The photovoltaic performance of the DSSC using chemically synthesized PEDOT exceeds that of a Pt-electrode device because of the enhanced current density, which is directly related to the superior electrocatalytic ability of PEDOT for Co(III)-reduction. This simple spin-coated counter electrode prepared using cheap and scalable chemically synthesized PEDOT can be a potential alternative to the expensive Pt-counter electrode for cobalt and other redox electrolytes in DSSCs and various flexible electronic devices.
Collapse
Affiliation(s)
- Masud
- Global GET-Future Lab., Department of Advanced Materials Chemistry, Korea University, 2511 Sejong-ro, Sejong 339-700, Republic of Korea.
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-Ro, Nam-Gu Pohang, Gyeongbuk, Republic of Korea.
- Department of Biomedical Engineering, College of Life Science and Biotechnology, Dongguk University, Seoul 04620, Republic of Korea
| | - Md Aftabuzzaman
- Global GET-Future Lab., Department of Advanced Materials Chemistry, Korea University, 2511 Sejong-ro, Sejong 339-700, Republic of Korea.
| | - Haoran Zhou
- Global GET-Future Lab., Department of Advanced Materials Chemistry, Korea University, 2511 Sejong-ro, Sejong 339-700, Republic of Korea.
- Renewable Energy Materials Laboratory (REML), Advanced Institute of Convergence Technology, Seoul National University, Suwon 16229, Republic of Korea
| | - Saehyun Kim
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-Ro, Nam-Gu Pohang, Gyeongbuk, Republic of Korea.
| | - Jaekyung Yi
- Department of Chemistry, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea
| | - Sarah S Park
- Department of Chemistry, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea
| | - Youn Soo Kim
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-Ro, Nam-Gu Pohang, Gyeongbuk, Republic of Korea.
| | - Hwan Kyu Kim
- Global GET-Future Lab., Department of Advanced Materials Chemistry, Korea University, 2511 Sejong-ro, Sejong 339-700, Republic of Korea.
| |
Collapse
|
3
|
Tian X, Qin Y, Jiang Y, Guo X, Wen Y, Yang H. Chemically renewable SERS sensor for the inspection of H 2O 2 residue in food stuff. Food Chem 2024; 438:137777. [PMID: 37979276 DOI: 10.1016/j.foodchem.2023.137777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 09/30/2023] [Accepted: 10/14/2023] [Indexed: 11/20/2023]
Abstract
Hydrogen peroxide (H2O2) residue in foodstuffs will bring great harm to human health. We immobilize the composite of the reduced polyaniline (PANIR) modified gold nanoparticles on the surface of ITO (ITO/AuNPs/PANIR) to develop surface-enhanced Raman scattering (SERS) sensor for H2O2.detection. The principle is that PANIR is oxidized by H2O2 to generate a new SERS peak at 1460 cm-1 for realizing quantitative analysis of H2O2. Fe2+-Fenton reaction is introduced to catalytically react with H2O2 to hydroxyl radical, which speeds up the oxidation of PANIR. Before SERS detection, acidic treatment could guarantee the reduced state of PANIR in composite. Limit of detection of ITO/AuNPs/PANIR-based SERS assay for H2O2 is down to 1.78 × 10-12 mol/L and a good linear relationship from 1 × 10-10 to 3.16 × 10-7 mol/L is achieved. Furthermore, the SERS sensor could be regenerated by acidic treatment. As a scenario, the renewable SERS sensor is utilized to monitor H2O2 residues in food and environmental samples.
Collapse
Affiliation(s)
- Xin Tian
- The Education Ministry Key Lab of Resource Chemistry, and Shanghai Frontiers Science Center of Biomimetic Catalysis, Shanghai Normal University, Shanghai 200234, China
| | - Yun Qin
- The Education Ministry Key Lab of Resource Chemistry, and Shanghai Frontiers Science Center of Biomimetic Catalysis, Shanghai Normal University, Shanghai 200234, China
| | - Yuning Jiang
- The Education Ministry Key Lab of Resource Chemistry, and Shanghai Frontiers Science Center of Biomimetic Catalysis, Shanghai Normal University, Shanghai 200234, China
| | - Xiaoyu Guo
- The Education Ministry Key Lab of Resource Chemistry, and Shanghai Frontiers Science Center of Biomimetic Catalysis, Shanghai Normal University, Shanghai 200234, China
| | - Ying Wen
- The Education Ministry Key Lab of Resource Chemistry, and Shanghai Frontiers Science Center of Biomimetic Catalysis, Shanghai Normal University, Shanghai 200234, China
| | - Haifeng Yang
- The Education Ministry Key Lab of Resource Chemistry, and Shanghai Frontiers Science Center of Biomimetic Catalysis, Shanghai Normal University, Shanghai 200234, China.
| |
Collapse
|
4
|
Wachholz Junior D, Hryniewicz BM, Tatsuo Kubota L. Advanced Hybrid materials in electrochemical sensors: Combining MOFs and conducting polymers for environmental monitoring. CHEMOSPHERE 2024; 352:141479. [PMID: 38367874 DOI: 10.1016/j.chemosphere.2024.141479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 02/07/2024] [Accepted: 02/15/2024] [Indexed: 02/19/2024]
Abstract
The integration of conducting polymers (CPs) with metal-organic frameworks (MOFs) has arisen as a dynamic and innovative approach to overcome some intrinsic limitations of both materials, representing a transformative method to address the pressing need for high-performance environmental monitoring tools. MOFs, with their intricate structures and versatile functional groups, provide tuneable porosity and an extensive surface area, facilitating the selective adsorption of target analytes. Conversely, CPs, characterized by their exceptional electrical conductivity and redox properties, serve as proficient signal transducers. By combining these two materials, a novel class of hybrid materials emerges, capitalizing on the unique attributes of both components. These MOF/CP hybrids exhibit heightened sensitivity, selectivity, and adaptability, making them primordial in detecting and quantifying environmental contaminants. This review examines the synergy between MOFs and CPs, highlighting recent advancements, challenges, and prospects, thus offering a promising solution for developing advanced functional materials with tailored properties and multifunctionality to be applied in electrochemical sensors for environmental monitoring.
Collapse
Affiliation(s)
- Dagwin Wachholz Junior
- Institute of Chemistry, University of Campinas - UNICAMP, 13083-970, Campinas, Brazil; National Institute of Science and Technology in Bioanalytic, Campinas, Brazil.
| | - Bruna M Hryniewicz
- Institute of Chemistry, University of Campinas - UNICAMP, 13083-970, Campinas, Brazil; National Institute of Science and Technology in Bioanalytic, Campinas, Brazil.
| | - Lauro Tatsuo Kubota
- Institute of Chemistry, University of Campinas - UNICAMP, 13083-970, Campinas, Brazil; National Institute of Science and Technology in Bioanalytic, Campinas, Brazil.
| |
Collapse
|
5
|
Patra S, Pareek D, Gupta PS, Wasnik K, Singh G, Yadav DD, Mastai Y, Paik P. Progress in Treatment and Diagnostics of Infectious Disease with Polymers. ACS Infect Dis 2024; 10:287-316. [PMID: 38237146 DOI: 10.1021/acsinfecdis.3c00528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/10/2024]
Abstract
In this era of advanced technology and innovation, infectious diseases still cause significant morbidity and mortality, which need to be addressed. Despite overwhelming success in the development of vaccines, transmittable diseases such as tuberculosis and AIDS remain unprotected, and the treatment is challenging due to frequent mutations of the pathogens. Formulations of new or existing drugs with polymeric materials have been explored as a promising new approach. Variations in shape, size, surface charge, internal morphology, and functionalization position polymer particles as a revolutionary material in healthcare. Here, an overview is provided of major diseases along with statistics on infection and death rates, focusing on polymer-based treatments and modes of action. Key issues are discussed in this review pertaining to current challenges and future perspectives.
Collapse
Affiliation(s)
- Sukanya Patra
- School of Biomedical Engineering, Indian Institute of Technology-BHU, Varanasi 221005, India
| | - Divya Pareek
- School of Biomedical Engineering, Indian Institute of Technology-BHU, Varanasi 221005, India
| | - Prem Shankar Gupta
- School of Biomedical Engineering, Indian Institute of Technology-BHU, Varanasi 221005, India
| | - Kirti Wasnik
- School of Biomedical Engineering, Indian Institute of Technology-BHU, Varanasi 221005, India
| | - Gurmeet Singh
- School of Biomedical Engineering, Indian Institute of Technology-BHU, Varanasi 221005, India
| | - Desh Deepak Yadav
- School of Biomedical Engineering, Indian Institute of Technology-BHU, Varanasi 221005, India
| | - Yitzhak Mastai
- Department of Chemistry, Bar-Ilan University, Ramat-Gan 5290002, Israel
| | - Pradip Paik
- School of Biomedical Engineering, Indian Institute of Technology-BHU, Varanasi 221005, India
| |
Collapse
|
6
|
Meshesha M, Sardar A, Supekar R, Bhattacharjee L, Chatterjee S, Halder N, Mohanta K, Bhattacharyya TK, Pal B. Development and Analytical Evaluation of a Point-of-Care Electrochemical Biosensor for Rapid and Accurate SARS-CoV-2 Detection. SENSORS (BASEL, SWITZERLAND) 2023; 23:8000. [PMID: 37766054 PMCID: PMC10534802 DOI: 10.3390/s23188000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 09/15/2023] [Accepted: 09/19/2023] [Indexed: 09/29/2023]
Abstract
The COVID-19 pandemic has underscored the critical need for rapid and accurate screening and diagnostic methods for potential respiratory viruses. Existing COVID-19 diagnostic approaches face limitations either in terms of turnaround time or accuracy. In this study, we present an electrochemical biosensor that offers nearly instantaneous and precise SARS-CoV-2 detection, suitable for point-of-care and environmental monitoring applications. The biosensor employs a stapled hACE-2 N-terminal alpha helix peptide to functionalize an in situ grown polypyrrole conductive polymer on a nitrocellulose membrane backbone through a chemical process. We assessed the biosensor's analytical performance using heat-inactivated omicron and delta variants of the SARS-CoV-2 virus in artificial saliva (AS) and nasal swab (NS) samples diluted in a strong ionic solution, as well as clinical specimens with known Ct values. Virus identification was achieved through electrochemical impedance spectroscopy (EIS) and frequency analyses. The assay demonstrated a limit of detection (LoD) of 40 TCID50/mL, with 95% sensitivity and 100% specificity. Notably, the biosensor exhibited no cross-reactivity when tested against the influenza virus. The entire testing process using the biosensor takes less than a minute. In summary, our biosensor exhibits promising potential in the battle against pandemic respiratory viruses, offering a platform for the development of rapid, compact, portable, and point-of-care devices capable of multiplexing various viruses. The biosensor has the capacity to significantly bolster our readiness and response to future viral outbreaks.
Collapse
Affiliation(s)
- Mesfin Meshesha
- Department of Virology, Opteev Technologies Inc., Baltimore, MD 21225, USA;
| | - Anik Sardar
- Research and Development Laboratory, Opteev Healthtech, GN-4, Sector-V, Kolkata 700091, India; (A.S.); (R.S.); (L.B.); (S.C.); (N.H.); (K.M.)
| | - Ruchi Supekar
- Research and Development Laboratory, Opteev Healthtech, GN-4, Sector-V, Kolkata 700091, India; (A.S.); (R.S.); (L.B.); (S.C.); (N.H.); (K.M.)
| | - Lopamudra Bhattacharjee
- Research and Development Laboratory, Opteev Healthtech, GN-4, Sector-V, Kolkata 700091, India; (A.S.); (R.S.); (L.B.); (S.C.); (N.H.); (K.M.)
| | - Soumyo Chatterjee
- Research and Development Laboratory, Opteev Healthtech, GN-4, Sector-V, Kolkata 700091, India; (A.S.); (R.S.); (L.B.); (S.C.); (N.H.); (K.M.)
| | - Nyancy Halder
- Research and Development Laboratory, Opteev Healthtech, GN-4, Sector-V, Kolkata 700091, India; (A.S.); (R.S.); (L.B.); (S.C.); (N.H.); (K.M.)
| | - Kallol Mohanta
- Research and Development Laboratory, Opteev Healthtech, GN-4, Sector-V, Kolkata 700091, India; (A.S.); (R.S.); (L.B.); (S.C.); (N.H.); (K.M.)
| | - Tarun Kanti Bhattacharyya
- Department of Electronics and Electrical Communication Engineering, Indian Institute of Technology, Kharagpur 721302, India;
| | - Biplab Pal
- Department of Virology, Opteev Technologies Inc., Baltimore, MD 21225, USA;
- Research and Development Laboratory, Opteev Healthtech, GN-4, Sector-V, Kolkata 700091, India; (A.S.); (R.S.); (L.B.); (S.C.); (N.H.); (K.M.)
| |
Collapse
|
7
|
Fraga VM, Lovi IT, Abegão LMG, Mello HJNPD. Understanding the Effect of Deposition Technique on the Structure-Property Relationship of Polyaniline Thin Films Applied in Potentiometric pH Sensor. Polymers (Basel) 2023; 15:3450. [PMID: 37631510 PMCID: PMC10459526 DOI: 10.3390/polym15163450] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 08/08/2023] [Accepted: 08/16/2023] [Indexed: 08/27/2023] Open
Abstract
The comprehension of potentiometric pH sensors with polymeric thin films for new and advanced applications is a constant technological need. The present study aimed to explore the relationship between the sensitivity and correlation coefficient of potentiometric pH sensors and the structure-property relationship of polyaniline thin films. The effect of the deposition method on the sample's properties was evaluated. Galvanostatically electrodeposited and spin-coated polyaniline thin films were used as the sensing stage. Samples were electrodeposited with a current density of 0.5 mA/cm2 for 300, 600, and 1200 s and were spin coated for 60 s with an angular velocity of 500, 1000, and 2000 rpm. The electrodeposited set of films presented higher average sensitivity, 73.4 ± 1.3 mV/pH, compared to the spin-coated set, 59.2 ± 2.5 mV/pH. The electrodeposited films presented higher sensitivity due to their morphology, characterized by a larger roughness and thickness compared to spin-coated ones, favoring the potentiometric response. Also, their oxidation state, evaluated with cyclic voltammetry and UV-VIS spectroscopy, corroborates their sensing performance. The understanding of the structure-property relationship of the polymeric films affecting the pH detection is discussed based on the characteristics of the deposition method used.
Collapse
Affiliation(s)
- Vinicius M. Fraga
- Materials Physics Group, Physics Institute, Goiás Federal University, Samambaia Campus, Goiânia 74001-970, GO, Brazil; (V.M.F.); (I.T.L.)
| | - Isabela T. Lovi
- Materials Physics Group, Physics Institute, Goiás Federal University, Samambaia Campus, Goiânia 74001-970, GO, Brazil; (V.M.F.); (I.T.L.)
| | - Luis M. G. Abegão
- Photonics Group, Physics Institute, Goiás Federal University, Samambaia Campus, Goiânia 74001-970, GO, Brazil
| | - Hugo J. N. P. D. Mello
- Materials Physics Group, Physics Institute, Goiás Federal University, Samambaia Campus, Goiânia 74001-970, GO, Brazil; (V.M.F.); (I.T.L.)
| |
Collapse
|
8
|
Nguyen TN, Phung VD, Tran VV. Recent Advances in Conjugated Polymer-Based Biosensors for Virus Detection. BIOSENSORS 2023; 13:586. [PMID: 37366951 DOI: 10.3390/bios13060586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/24/2023] [Accepted: 05/26/2023] [Indexed: 06/28/2023]
Abstract
Nowadays, virus pandemics have become a major burden seriously affecting human health and social and economic development. Thus, the design and fabrication of effective and low-cost techniques for early and accurate virus detection have been given priority for prevention and control of such pandemics. Biosensors and bioelectronic devices have been demonstrated as promising technology to resolve the major drawbacks and problems of the current detection methods. Discovering and applying advanced materials have offered opportunities to develop and commercialize biosensor devices for effectively controlling pandemics. Along with various well-known materials such as gold and silver nanoparticles, carbon-based materials, metal oxide-based materials, and graphene, conjugated polymer (CPs) have become one of the most promising candidates for preparation and construction of excellent biosensors with high sensitivity and specificity to different virus analytes owing to their unique π orbital structure and chain conformation alterations, solution processability, and flexibility. Therefore, CP-based biosensors have been regarded as innovative technologies attracting great interest from the community for early diagnosis of COVID-19 as well as other virus pandemics. For providing precious scientific evidence of CP-based biosensor technologies in virus detection, this review aims to give a critical overview of the recent research related to use of CPs in fabrication of virus biosensors. We emphasize structures and interesting characteristics of different CPs and discuss the state-of-the-art applications of CP-based biosensors as well. In addition, different types of biosensors such as optical biosensors, organic thin film transistors (OTFT), and conjugated polymer hydrogels (CPHs) based on CPs are also summarized and presented.
Collapse
Affiliation(s)
- Thanh Ngoc Nguyen
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, 300A Nguyen Tat Thanh, Ward 13, District 4, Ho Chi Minh City 700000, Vietnam
| | - Viet-Duc Phung
- Institute of Fundamental and Applied Sciences, Duy Tan University, Ho Chi Minh City 700000, Vietnam
- Faculty of Environmental and Chemical Engineering, Duy Tan University, Da Nang 550000, Vietnam
| | - Vinh Van Tran
- Department of Mechanical Engineering, Gachon University, Seongnam 13120, Republic of Korea
| |
Collapse
|
9
|
Vajhadin F, Mazloum-Ardakani M, Hemati M, Moshtaghioun SM. Facile preparation of a cost-effective platform based on ZnFe 2O 4 nanomaterials for electrochemical cell detection. Sci Rep 2023; 13:4962. [PMID: 36973342 PMCID: PMC10042879 DOI: 10.1038/s41598-023-31377-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Accepted: 03/10/2023] [Indexed: 03/29/2023] Open
Abstract
Circulating tumor cells (CTCs) are important tumor markers that indicate early metastasis, tumor recurrence, and treatment efficacy. To identify and separate these cells from the blood, new nanomaterials need to be developed. The present study explored the potential application of ZnFe2O4 magnetic nanoparticles in capturing CTCs with cell surface markers. Folic acid was coupled to L-cysteine-capped ZnFe2O4 nanoparticles (ZC) to provide binding sites on ZnFe2O4 nanoparticles for the recognition of folate bioreceptors, which are highly expressed in MCF-7 breast cancer cells. The cytotoxicity of ZnFe2O4 nanoparticles and ZC against MCF-7 was analyzed with the MTT assay. After 24 h of incubation, there were IC50 values of 702.6 and 805.5 µg/mL for ZnFe2O4 and ZC, respectively. However, after 48 h of incubation, IC50 values of ZnFe2O4 and ZC were reduced to 267.3 and 389.7 µg/mL, respectively. The cell quantification was conducted with magnetically collected cells placed on a glassy carbon electrode, and the differential pulse voltammetry (DPV) responses were analyzed. This cost-effective ZnFe2O4-based biosensing platform allowed cancer cell detection with a limit of detection of 3 cells/mL, ranging from 25 to 104 cells/mL. In future, these functionalized zinc ferrites may be used in electrochemical cell detection and targeted cancer therapy.
Collapse
Affiliation(s)
- Fereshteh Vajhadin
- Department of Chemistry, Faculty of Science, Yazd University, Yazd, 8915818411, Iran
| | | | - Mahdie Hemati
- Department of Clinical Biochemistry, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
- Medical Nanotechnology & Tissue Engineering Research Center, Yazd Reproductive Sciences Institute, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | | |
Collapse
|
10
|
Cruz-Pacheco AF, Quinchia J, Orozco J. Nanostructured poly(thiophene acetic acid)/Au/poly(methylene blue) interface for electrochemical immunosensing of p53 protein. Mikrochim Acta 2023; 190:136. [PMID: 36920574 DOI: 10.1007/s00604-023-05683-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 01/30/2023] [Indexed: 03/16/2023]
Abstract
A poly(thiophene acetic acid)/Au/poly(methylene blue) nanostructured interface was electrochemically assembled step-by-step on screen-printed carbon electrodes (SPCE) for label-free detection of p53 protein. The initial electrical conductive properties of the polymeric interface were increased with an additional layer of poly(methylene blue) electropolymerized in the presence of gold nanoparticles. The nano-immunosensing architecture was prepared by covalent immobilization of anti-p53 antibodies as bioreceptors through the poly(thiophene acetic acid) moieties. The nano-immunosensor assembly was extensively characterized by ultraviolet-visible spectrophotometry, dynamic and electrophoretic light scattering, scanning electron microscopy, X-ray photoelectron spectroscopy, Raman spectroscopy, atomic force microscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. Under optimal conditions, p53 was specifically and selectively detected by square wave voltammetry in a linear range between 1 and 100 ng mL-1 with a limit of detection of 0.65 ng mL-1. In addition, the electrochemical nano-immunosensor detected p53 in spiked human serum samples and colorectal cancer cell lysates, and the results were validated with a standard spectrophotometric method using a paired samples t test, which did not exhibit significant differences between both methods. The resultant p53 nano-immunosensor is simple to assemble, robust, and has the potential for point-of-care biomarker detection applications.
Collapse
Affiliation(s)
- Andrés F Cruz-Pacheco
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67 No. 52-20, 050010, Medellín, Colombia
| | - Jennifer Quinchia
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67 No. 52-20, 050010, Medellín, Colombia
| | - Jahir Orozco
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67 No. 52-20, 050010, Medellín, Colombia.
| |
Collapse
|
11
|
Rossignatti BC, Vieira AP, Barbosa MS, Abegão LMG, Mello HJNPD. Thin Films of Polyaniline-Based Nanocomposites with CeO 2 and WO 3 Metal Oxides Applied to the Impedimetric and Capacitive Transducer Stages in Chemical Sensors. Polymers (Basel) 2023; 15:polym15030578. [PMID: 36771879 PMCID: PMC9920537 DOI: 10.3390/polym15030578] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 01/06/2023] [Accepted: 01/19/2023] [Indexed: 01/24/2023] Open
Abstract
There is a recognized need for the development of cost-effective, stable, fast, and optimized novel materials for technological applications. Substantial research has been undertaken on the role of polymeric nanocomposites in sensing applications. However, the use of PANI-based nanocomposites in impedimetric and capacitive electrochemical sensors has yet to be understood. The present study aimed to explore the relationship between the sensitivity and linearity of electrochemical pH sensors and the composition of nanocomposites. Thin films of PANI/CeO2 and PANI/WO3 were deposited via spin coating for characterization and application during the electrochemical impedance and capacitance spectroscopy (EIS and ECS) transduction stages. The findings showed that the optimized performance of the devices was extended not only to the sensitivity but also to the linearity. An increase of 213% in the ECS sensitivity of the PANI/CeO2 compared to the metal oxide and an increase of 64% in the ECS linearity of the PANI/WO3 compared to the polymeric sensitivity were reported. This study identified the structure-property relationship of nanocomposite thin films of PANI with metal oxides for use in electrochemical sensors. The developed materials could be applied in devices to be used in different fields, such as food, environment, and biomedical monitoring.
Collapse
Affiliation(s)
| | - Amanda Portes Vieira
- Physics Institute, Goiás Federal University, Samambaia Campus, Goiânia 74001-970, GO, Brazil
| | | | | | | |
Collapse
|
12
|
Pillai RR, Thomas V. Plasma Surface Engineering of Natural and Sustainable Polymeric Derivatives and Their Potential Applications. Polymers (Basel) 2023; 15:400. [PMID: 36679280 PMCID: PMC9863272 DOI: 10.3390/polym15020400] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 01/03/2023] [Accepted: 01/05/2023] [Indexed: 01/14/2023] Open
Abstract
Recently, natural as well as synthetic polymers have been receiving significant attention as candidates to replace non-renewable materials. With the exponential developments in the world each day, the collateral damage to the environment is incessant. Increased demands for reducing pollution and energy consumption are the driving force behind the research related to surface-modified natural fibers (NFs), polymers, and various derivatives of them such as natural-fiber-reinforced polymer composites. Natural fibers have received special attention for industrial applications due to their favorable characteristics, such as low cost, abundance, light weight, and biodegradable nature. Even though NFs offer many potential applications, they still face some challenges in terms of durability, strength, and processing. Many of these have been addressed by various surface modification methodologies and compositing with polymers. Among different surface treatment strategies, low-temperature plasma (LTP) surface treatment has recently received special attention for tailoring surface properties of different materials, including NFs and synthetic polymers, without affecting any of the bulk properties of these materials. Hence, it is very important to get an overview of the latest developments in this field. The present article attempts to give an overview of different materials such as NFs, synthetic polymers, and composites. Special attention was placed on the low-temperature plasma-based surface engineering of these materials for diverse applications, which include but are not limited to environmental remediation, packaging, biomedical devices, and sensor development.
Collapse
Affiliation(s)
| | - Vinoy Thomas
- Department of Material Science and Engineering, The University of Alabama at Birmingham, Birmingham, AL 35294, USA
| |
Collapse
|
13
|
Bauer M, Duerkop A, Baeumner AJ. Critical review of polymer and hydrogel deposition methods for optical and electrochemical bioanalytical sensors correlated to the sensor's applicability in real samples. Anal Bioanal Chem 2023; 415:83-95. [PMID: 36280625 PMCID: PMC9816278 DOI: 10.1007/s00216-022-04363-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 09/24/2022] [Accepted: 09/27/2022] [Indexed: 01/11/2023]
Abstract
Sensors, ranging from in vivo through to single-use systems, employ protective membranes or hydrogels to enhance sample collection or serve as filters, to immobilize or entrap probes or receptors, or to stabilize and enhance a sensor's lifetime. Furthermore, many applications demand specific requirements such as biocompatibility and non-fouling properties for in vivo applications, or fast and inexpensive mass production capabilities for single-use sensors. We critically evaluated how membrane materials and their deposition methods impact optical and electrochemical systems with special focus on analytical figures of merit and potential toward large-scale production. With some chosen examples, we highlight the fact that often a sensor's performance relies heavily on the deposition method, even though other methods or materials could in fact improve the sensor. Over the course of the last 5 years, most sensing applications within healthcare diagnostics included glucose, lactate, uric acid, O2, H+ ions, and many specific metabolites and markers. In the case of food safety and environmental monitoring, the choice of analytes was much more comprehensive regarding a variety of natural and synthetic toxicants like bacteria, pesticides, or pollutants and other relevant substances. We conclude that more attention must be paid toward deposition techniques as these may in the end become a major hurdle in a sensor's likelihood of moving from an academic lab into a real-world product.
Collapse
Affiliation(s)
- Meike Bauer
- grid.7727.50000 0001 2190 5763Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93040 Regensburg, Germany
| | - Axel Duerkop
- grid.7727.50000 0001 2190 5763Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93040 Regensburg, Germany
| | - Antje J. Baeumner
- grid.7727.50000 0001 2190 5763Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93040 Regensburg, Germany ,grid.5386.8000000041936877XDepartment of Biological and Environmental Engineering, Cornell University, Ithaca, NY 14853 USA
| |
Collapse
|
14
|
Kappen J, Skorupa M, Krukiewicz K. Conducting Polymers as Versatile Tools for the Electrochemical Detection of Cancer Biomarkers. BIOSENSORS 2022; 13:bios13010031. [PMID: 36671866 PMCID: PMC9856009 DOI: 10.3390/bios13010031] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 12/16/2022] [Accepted: 12/23/2022] [Indexed: 05/14/2023]
Abstract
The detection of cancer biomarkers has recently become an established method for the early diagnosis of cancer. The sensitive analysis of specific biomarkers can also be clinically applied for the determination of response to treatment and monitoring of disease progression. Because of the ultra-low concentration of cancer biomarkers in body fluids, diagnostic tools need to be highly sensitive and specific. Conducting polymers (CPs) are particularly known to exhibit numerous features that enable them to serve as excellent materials for the immobilization of biomolecules and the facilitation of electron transfer. Their large surface area, porosity, and the presence of functional groups provide CPs with binding sites suitable for capturing biomarkers, in addition to their sensitive and easy detection. The aim of this review is to present a comprehensive summary of the available electrochemical biosensors based on CPs and their composites for the ultrasensitive detection of selected cancer biomarkers. We have categorized the study based on different types of targeted biomarkers such as DNAs, miRNAs, proteins, enzymes, neurotransmitters and whole cancer cells. The sensitivity of their detection is enhanced by the presence of CPs, providing a limit of detection as low as 0.5 fM (for miRNA) and 10 cells (for the detection of cancer cells). The methods of multiplex biomarker detection and cell capture are indicated as the most promising category, since they furnish more accurate and reliable results. Ultimately, we discuss the available CP-based electrochemical sensors and promising approaches for facilitating cancer diagnosis and treatment.
Collapse
Affiliation(s)
- Jincymol Kappen
- Centre for Nanoscience and Nanotechnology, Department of Chemistry, The Gandhigram Rural Institute-Deemed to be University, Dindigul 624 302, Tamilnadu, India
| | - Małgorzata Skorupa
- Department of Physical Chemistry and Technology of Polymers, Silesian University of Technology, M. Strzody 9, 44-100 Gliwice, Poland
- Joint Doctoral School, Silesian University of Technology, Akademicka 2A, 44-100 Gliwice, Poland
| | - Katarzyna Krukiewicz
- Department of Physical Chemistry and Technology of Polymers, Silesian University of Technology, M. Strzody 9, 44-100 Gliwice, Poland
- Centre for Organic and Nanohybrid Electronics, Silesian University of Technology, S. Konarskiego 22B, 44-100 Gliwice, Poland
- Correspondence: ; Tel.: +48-32-237-1773
| |
Collapse
|
15
|
Ashraf J, Lau S, Akbarinejad A, Evans CW, Williams DE, Barker D, Travas-Sejdic J. Conducting Polymer-Infused Electrospun Fibre Mat Modified by POEGMA Brushes as Antifouling Biointerface. BIOSENSORS 2022; 12:1143. [PMID: 36551110 PMCID: PMC9775683 DOI: 10.3390/bios12121143] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 11/29/2022] [Accepted: 12/05/2022] [Indexed: 06/17/2023]
Abstract
Biofouling on surfaces, caused by the assimilation of proteins, peptides, lipids and microorganisms, leads to contamination, deterioration and failure of biomedical devices and causes implants rejection. To address these issues, various antifouling strategies have been extensively studied, including polyethylene glycol-based polymer brushes. Conducting polymers-based biointerfaces have emerged as advanced surfaces for interfacing biological tissues and organs with electronics. Antifouling of such biointerfaces is a challenge. In this study, we fabricated electrospun fibre mats from sulphonated polystyrene-block-poly(ethylene-ran-butylene)-block-polystyrene (sSEBS), infused with conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) (sSEBS-PEDOT), to produce a conductive (2.06 ± 0.1 S/cm), highly porous, fibre mat that can be used as a biointerface in bioelectronic applications. To afford antifouling, here the poly(oligo (ethylene glycol) methyl ether methacrylate) (POEGMA) brushes were grafted onto the sSEBS-PEDOT conducting fibre mats via surface-initiated atom transfer radical polymerization technique (SI-ATRP). For that, a copolymer of EDOT and an EDOT derivative with SI-ATRP initiating sites, 3,4-ethylenedioxythiophene) methyl 2-bromopropanoate (EDOTBr), was firstly electropolymerized on the sSEBS-PEDOT fibre mat to provide sSEBS-PEDOT/P(EDOT-co-EDOTBr). The POEGMA brushes were grafted from the sSEBS-PEDOT/P(EDOT-co-EDOTBr) and the polymerization kinetics confirmed the successful growth of the brushes. Fibre mats with 10-mers and 30-mers POEGMA brushes were studied for antifouling using a BCA protein assay. The mats with 30-mers grafted brushes exhibited excellent antifouling efficiency, ~82% of proteins repelled, compared to the pristine sSEBS-PEDOT fibre mat. The grafted fibre mats exhibited cell viability >80%, comparable to the standard cell culture plate controls. Such conducting, porous biointerfaces with POEGMA grafted brushes are suitable for applications in various biomedical devices, including biosensors, liquid biopsy, wound healing substrates and drug delivery systems.
Collapse
Affiliation(s)
- Jesna Ashraf
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - Sandy Lau
- Hub for Extracellular Vesicles Investigation (HEVI), Department of Obstetrics and Gynecology, The University of Auckland, Auckland 1010, New Zealand
| | - Alireza Akbarinejad
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - Clive W. Evans
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- School of Biological Sciences, The University of Auckland, Auckland 1010, New Zealand
| | - David E. Williams
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - David Barker
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - Jadranka Travas-Sejdic
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| |
Collapse
|
16
|
Tran VV. Conjugated Polymers-Based Biosensors for Virus Detection: Lessons from COVID-19. BIOSENSORS 2022; 12:bios12090748. [PMID: 36140133 PMCID: PMC9496581 DOI: 10.3390/bios12090748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Accepted: 09/09/2022] [Indexed: 11/16/2022]
Abstract
Human beings continue to endure the coronavirus disease (COVID-19) pandemic, which has spread throughout the world and significantly affected all countries and territories, causing a socioeconomic crunch. Human pathogenic viruses are considered a global burden for public health, both in the present and the future. Therefore, the early and accurate diagnosis of viruses has been and still is critical and should be accorded a degree of priority that is equivalent to vaccinations and drugs. We have opened a Special Issue titled “Conjugated polymers-based biosensors for virus detection”. This editorial seeks to emphasize the importance and potential of conjugated polymers in the design and development of biosensors. Furthermore, we briefly provide an overview, scientific evidence, and opinions on promising strategies for the development of CP-based electrochemical biosensors for virus detection.
Collapse
Affiliation(s)
- Vinh Van Tran
- Laser and Thermal Engineering Laboratory, Department of Mechanical Engineering, Gachon University, Seongnam 13120, Korea
| |
Collapse
|
17
|
Oaki Y, Sato K. Nanoarchitectonics for conductive polymers using solid and vapor phases. NANOSCALE ADVANCES 2022; 4:2773-2781. [PMID: 36132001 PMCID: PMC9418446 DOI: 10.1039/d2na00203e] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 04/21/2022] [Indexed: 05/03/2023]
Abstract
Conductive polymers have been extensively studied as functional organic materials due to their broad range of applications. Conductive polymers, such as polypyrrole, polythiophene, and their derivatives, are typically obtained as coatings and precipitates in the solution phase. Nanoarchitectonics for conductive polymers requires new methods including syntheses and morphology control. For example, nanoarchitectonics is achieved by liquid-phase syntheses with the assistance of templates, such as macromolecules and porous materials. This minireview summarizes the other new synthetic methods using the solid and vapor phases for nanoarchitectonics. In general, the monomers and related species are supplied from the solution phase. Our group has studied polymerization of heteroaromatic monomers using the solid and vapor phases. The surface and inside of solid crystals were used for the polymerization with the diffusion of the heteroaromatic monomer vapor. Our nanoarchitectonics affords to form homogeneous coatings, hierarchical structures, composites, and copolymers for energy-related applications. The concepts using solid and vapor phases can be applied to nanoarchitectonics for not only conductive polymers but also other polymers toward a variety of applications.
Collapse
Affiliation(s)
- Yuya Oaki
- Department of Applied Chemistry, Faculty of Science and Technology, Keio University 3-14-1 Hiyoshi, Kohoku-ku Yokohama 223-8522 Japan
| | - Kosuke Sato
- Department of Applied Chemistry, Faculty of Science and Technology, Keio University 3-14-1 Hiyoshi, Kohoku-ku Yokohama 223-8522 Japan
- Organic Materials Chemistry Group, Sagami Chemical Research Institute 2743-1 Hayakawa Ayase Kanagawa 252-1193 Japan
| |
Collapse
|
18
|
Dokur E, Uruc S, Gorduk O, Sahin Y. Ultrasensitive Electrochemical Detection of Carcinoembryonic Antigen with a Label‐Free Immunosensor using Gold Nanoparticle‐Decorated Poly(pyrrole‐co‐3,4‐ethylenedioxythiophene). ChemElectroChem 2022. [DOI: 10.1002/celc.202200121] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Ebrar Dokur
- Yildiz Technical University: Yildiz Teknik Universitesi Chemistry TURKEY
| | - Selen Uruc
- Yildiz Technical University: Yildiz Teknik Universitesi Chemistry TURKEY
| | - Ozge Gorduk
- Yildiz Technical University: Yildiz Teknik Universitesi Chemistry YTU 34210 Istanbul TURKEY
| | - Yucel Sahin
- Yildiz Technical University: Yildiz Teknik Universitesi Chemistry TURKEY
| |
Collapse
|
19
|
Bankole OE, Verma DK, Chávez González ML, Ceferino JG, Sandoval-Cortés J, Aguilar CN. Recent trends and technical advancements in biosensors and their emerging applications in food and bioscience. FOOD BIOSCI 2022. [DOI: 10.1016/j.fbio.2022.101695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
20
|
Gupta S, Datt R, Mishra A, Tsoi WC, Patra A, Bober P. Poly(3,4‐ethylenedioxythiophene):Poly(styrene sulfonate) in antibacterial, tissue engineering and biosensors applications: Progress, challenges and perspectives. J Appl Polym Sci 2022. [DOI: 10.1002/app.52663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Sonal Gupta
- Institute of Macromolecular Chemistry Czech Academy of Sciences Prague 6 Czech Republic
| | - Ram Datt
- SPECIFIC, Faculty of Science and Engineering, Swansea University Swansea United Kingdom
| | - Anamika Mishra
- Advanced Materials and Devices Metrology Division CSIR‐National Physical Laboratory New Delhi India
| | - Wing Chung Tsoi
- SPECIFIC, Faculty of Science and Engineering, Swansea University Swansea United Kingdom
| | - Asit Patra
- Advanced Materials and Devices Metrology Division CSIR‐National Physical Laboratory New Delhi India
| | - Patrycja Bober
- Institute of Macromolecular Chemistry Czech Academy of Sciences Prague 6 Czech Republic
| |
Collapse
|
21
|
Cerium oxide-doped PEDOT nanocomposite for label-free electrochemical immunosensing of anti-p53 autoantibodies. Mikrochim Acta 2022; 189:228. [PMID: 35610491 DOI: 10.1007/s00604-022-05322-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Accepted: 04/27/2022] [Indexed: 11/27/2022]
Abstract
A label-free nanoimmunosensor is reported based on p53/CeO2/PEDOT nanobiocomposite-decorated screen-printed gold electrodes (SPAuE) for the electrochemical detection of anti-p53 autoantibodies. CeO2 nanoparticles (NPs) were synthesized and stabilized with cyanopropyltriethoxysilane by a soft chemistry method. The nanoimmunosensing architecture was prepared by in situ electropolymerization of 3,4-ethylenedioxythiophene (EDOT) on SPAuE in the presence of CeO2 NPs. The CeO2 NPs and Ce/PEDOT/SPAuE were characterized by scanning and transmission electron microscopy, dynamic and electrophoretic light scattering, ultraviolet-visible spectrophotometry, X-ray diffraction, Fourier-transform infrared spectroscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. Ce/PEDOT/SPAuE was biofunctionalized with p53 antigen by covalent bonding for the label-free determination of anti-p53 autoantibodies by differential pulse voltammetry. The nanobiocomposite-based nanoimmunosensor detected anti-p53 autoantibodies in a linear range from 10 to 1000 pg mL-1, with a limit of detection (LOD) of 3.2 pg mL-1. The nanoimmunosensor offered high specificity, selectivity, and long-term storage stability with great potential to detect anti-p53 autoantibodies in serum samples. Overall, incorporating organo-functional nanoparticles into polymeric matrices can provide a simple-to-assemble, rapid, and ultrasensitive approach for on-site screening of anti-p53 autoantibodies and other disease-related biomarkers with low sample volumes.
Collapse
|
22
|
Wearable Near-Field Communication Sensors for Healthcare: Materials, Fabrication and Application. MICROMACHINES 2022; 13:mi13050784. [PMID: 35630251 PMCID: PMC9146494 DOI: 10.3390/mi13050784] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 04/18/2022] [Accepted: 04/21/2022] [Indexed: 01/27/2023]
Abstract
The wearable device industry is on the rise, with technology applications ranging from wireless communication technologies to the Internet of Things. However, most of the wearable sensors currently on the market are expensive, rigid and bulky, leading to poor data accuracy and uncomfortable wearing experiences. Near-field communication sensors are low-cost, easy-to-manufacture wireless communication technologies that are widely used in many fields, especially in the field of wearable electronic devices. The integration of wireless communication devices and sensors exhibits tremendous potential for these wearable applications by endowing sensors with new features of wireless signal transferring and conferring radio frequency identification or near-field communication devices with a sensing function. Likewise, the development of new materials and intensive research promotes the next generation of ultra-light and soft wearable devices for healthcare. This review begins with an introduction to the different components of near-field communication, with particular emphasis on the antenna design part of near-field communication. We summarize recent advances in different wearable areas of near-field communication sensors, including structural design, material selection, and the state of the art of scenario-based development. The challenges and opportunities relating to wearable near-field communication sensors for healthcare are also discussed.
Collapse
|
23
|
dos Santos DM, Cardoso RM, Migliorini FL, Facure MH, Mercante LA, Mattoso LH, Correa DS. Advances in 3D printed sensors for food analysis. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
24
|
Ting MS, Vella J, Raos BJ, Narasimhan BN, Svirskis D, Travas-Sejdic J, Malmström J. Conducting polymer hydrogels with electrically-tuneable mechanical properties as dynamic cell culture substrates. BIOMATERIALS ADVANCES 2022; 134:112559. [PMID: 35527144 DOI: 10.1016/j.msec.2021.112559] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 11/15/2021] [Accepted: 11/19/2021] [Indexed: 01/06/2023]
Abstract
Hydrogels are a popular substrate for cell culture due to their mechanical properties closely resembling natural tissue. Stimuli-responsive hydrogels are a good platform for studying cell response to dynamic stimuli. Poly(N-isopropylacrylamide) (pNIPAM) is a thermo-responsive polymer that undergoes a volume-phase transition when heated to 32 °C. Conducting polymers can be incorporated into hydrogels to introduce electrically responsive properties. The conducting polymer, polypyrrole (PPy), has been widely studied as electrochemical actuators due to its electrochemical stability, fast actuation and high strains. We determine the volume-phase transition temperature of pNIPAM hydrogels with PPy electropolymerised with different salts as a film within the hydrogel network. We also investigate the electro-mechanical properties at the transition temperature (32 °C) and physiological temperature (37 °C). We show statistically significant differences in the Young's modulus of the hybrid hydrogel at elevated temperatures upon electrochemical stimulation, with a 5 kPa difference at the transition temperature. Furthermore, we show a three-fold increase in actuation at transition temperature compared to room temperature and physiological temperature, attributed to the movement of ions in/out of the PPy film that induce the volume-phase transition of the pNIPAM hydrogel. Furthermore, cell adhesion to the hybrid hydrogel was demonstrated with mouse articular chondrocytes.
Collapse
Affiliation(s)
- Matthew S Ting
- Department of Chemical and Materials Engineering, The University of Auckland, Auckland, New Zealand; MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington, New Zealand; Polymer Biointerface Centre, The University of Auckland, Auckland, New Zealand
| | - Joseph Vella
- School of Chemical Sciences, The University of Auckland, Auckland, New Zealand
| | - Brad J Raos
- School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Badri Narayanan Narasimhan
- Department of Chemical and Materials Engineering, The University of Auckland, Auckland, New Zealand; MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington, New Zealand
| | - Darren Svirskis
- School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Jadranka Travas-Sejdic
- MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington, New Zealand; Polymer Biointerface Centre, The University of Auckland, Auckland, New Zealand; School of Chemical Sciences, The University of Auckland, Auckland, New Zealand
| | - Jenny Malmström
- Department of Chemical and Materials Engineering, The University of Auckland, Auckland, New Zealand; MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington, New Zealand; Polymer Biointerface Centre, The University of Auckland, Auckland, New Zealand.
| |
Collapse
|
25
|
Atomistic Simulations of Functionalized Nano-Materials for Biosensors Applications. Int J Mol Sci 2022; 23:ijms23031484. [PMID: 35163407 PMCID: PMC8835741 DOI: 10.3390/ijms23031484] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Revised: 12/30/2021] [Accepted: 12/31/2021] [Indexed: 12/24/2022] Open
Abstract
Nanoscale biosensors, a highly promising technique in clinical analysis, can provide sensitive yet label-free detection of biomolecules. The spatial and chemical specificity of the surface coverage, the proper immobilization of the bioreceptor as well as the underlying interfacial phenomena are crucial elements for optimizing the performance of a biosensor. Due to experimental limitations at the microscopic level, integrated cross-disciplinary approaches that combine in silico design with experimental measurements have the potential to present a powerful new paradigm that tackles the issue of developing novel biosensors. In some cases, computational studies can be seen as alternative approaches to assess the microscopic working mechanisms of biosensors. Nonetheless, the complex architecture of a biosensor, associated with the collective contribution from "substrate-receptor-analyte" conjugate in a solvent, often requires extensive atomistic simulations and systems of prohibitive size which need to be addressed. In silico studies of functionalized surfaces also require ad hoc force field parameterization, as existing force fields for biomolecules are usually unable to correctly describe the biomolecule/surface interface. Thus, the computational studies in this field are limited to date. In this review, we aim to introduce fundamental principles that govern the absorption of biomolecules onto functionalized nanomaterials and to report state-of-the-art computational strategies to rationally design nanoscale biosensors. A detailed account of available in silico strategies used to drive and/or optimize the synthesis of functionalized nanomaterials for biosensing will be presented. The insights will not only stimulate the field to rationally design functionalized nanomaterials with improved biosensing performance but also foster research on the required functionalization to improve biomolecule-surface complex formation as a whole.
Collapse
|
26
|
Vajhadin F, Mazloum-Ardakani M, Shahidi M, Moshtaghioun SM, Haghiralsadat F, Ebadi A, Amini A. MXene-based cytosensor for the detection of HER2-positive cancer cells using CoFe 2O 4@Ag magnetic nanohybrids conjugated to the HB5 aptamer. Biosens Bioelectron 2022; 195:113626. [PMID: 34543916 DOI: 10.1016/j.bios.2021.113626] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 08/31/2021] [Accepted: 09/10/2021] [Indexed: 12/20/2022]
Abstract
MXenes are a new class of conductive two-dimensional material which have received growing attention in biosensing for their significant surface area and unique surface chemistry. Here, gold electrodes were modified with MXene nanosheets of about 2 nm thickness and 1.5 μm lateral size for the electrochemical detection of tumor cells. An HB5 aptamer with high selectivity for HER-2 positive cells was immobilized on the MXene layers via electrostatic interactions. To minimize electrode biofouling with blood matrix, magnetic separation of HER-2 positive circulating tumor cells was carried out using CoFe2O4@Ag magnetic nanohybrids bonded to the HB5. The formation of sandwich-like structures between the magnetically captured cells and the functionalized MXene electrodes effectively shields the electron transfer of a redox probe, enabling quantitative cell detection using the change in current. This label-free MXene-based cytosensor platform yielded a wide linear range of 102-106 cells/mL, low detection limit of 47 cells/mL, and good sensitivity and selectivity in the detection of HER2-posetive cells in blood samples. The presented aptacytosensor demonstrates the great potential of using CoFe2O4@Ag magnetic nanohybrids and MXenes to monitor cancer progression via circulating tumor cells in blood at low cost.
Collapse
Affiliation(s)
- Fereshteh Vajhadin
- Department of Chemistry, Faculty of Science, Yazd University, Yazd, 89195-741, Iran
| | | | - Maryamsadat Shahidi
- Department of Clinical Biochemistry, School of Medicine, Shahid Sadoughi University of Medical Sciences and Health Services, Yazd, Iran
| | | | - Fateme Haghiralsadat
- Medical Nanotechnology & Tissue Engineering Research Center, Yazd Reproductive Sciences Institute, Shahid Sadoughi University of Medical Sciences, Yazd, Iran; Department of Advanced Medical Sciences and Technologies, School of Paramedicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Azar Ebadi
- Department of Chemistry, Faculty of Science, Yazd University, Yazd, 89195-741, Iran
| | - Abbas Amini
- Department of Mechanical Engineering, Australian College of Kuwait, Mishref, Safat 13015, Kuwait; Centre for Infrastructure Engineering, Western Sydney University, Penrith 2751, NSW, Australia
| |
Collapse
|
27
|
TANABE S, ITAGAKI S, SUEKUNI S, SHIIGI H. Development of an Electrochemical Evaluation for the Respiration of Escherichia coli. BUNSEKI KAGAKU 2021. [DOI: 10.2116/bunsekikagaku.70.715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- So TANABE
- Department of Applied Chemistry, Osaka Prefecture University
| | | | - Satoshi SUEKUNI
- Department of Applied Chemistry, Osaka Prefecture University
| | - Hiroshi SHIIGI
- Department of Applied Chemistry, Osaka Prefecture University
| |
Collapse
|
28
|
Supchocksoonthorn P, Alvior Sinoy MC, de Luna MDG, Paoprasert P. Facile fabrication of 17β-estradiol electrochemical sensor using polyaniline/carbon dot-coated glassy carbon electrode with synergistically enhanced electrochemical stability. Talanta 2021; 235:122782. [PMID: 34517640 DOI: 10.1016/j.talanta.2021.122782] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Revised: 06/18/2021] [Accepted: 08/02/2021] [Indexed: 12/26/2022]
Abstract
Previous 17β-estradiol sensors required expensive reagents or complicated fabrication of sensing probes. In this work, a cheap, simple, and reusable electrochemical sensor based on commercially available polyaniline (PANI) and carbon dots (CDs) synthesized from iota-carrageenan was developed for the sensitive detection of 17β-estradiol. The sensor was simply prepared by drop-casting CDs/PANI composite on a glassy carbon electrode (GCE) using poly(vinylidene fluoride) as a binder. With synergistic contributions from both CDs and PANI, the CDs-PANI/GCE was much more electrochemically stable than the CDs/GCE or PANI/GCE. The CDs-PANI/GCE was sensitive to 17β-estradiol across a linear range from 0.001 to 100 μmol L-1 with a detection limit of 43 nmol L-1. The electrochemical measurement can be performed in 2 min and the probe can be reused for several hundred times. The CDs-PANI/GCE was selective towards 17β-estradiol against several interferences and gave excellent recovery between 94.4 and 103.7 % from real sample analysis. From intensive investigation on electron transfer process and energy levels, the oxidation reaction of 17β-estradiol occurred on the surface of CDs-PANI/GCE via favorable energy levels and dominantly surface adsorption process through π-π stacking and hydrogen bonding between 17β-estradiol and CDs/PANI. Such unique interfacial interactions also resulted in the synergistically enhanced electrochemical stability of the modified electrode.
Collapse
Affiliation(s)
| | - Ma Concepcion Alvior Sinoy
- Department of Chemical Engineering, University of the Philippines, Diliman, 1101, Quezon City, Philippines
| | - Mark Daniel G de Luna
- Department of Chemical Engineering, University of the Philippines, Diliman, 1101, Quezon City, Philippines
| | - Peerasak Paoprasert
- Department of Chemistry, Faculty of Science and Technology, Thammasat University, Pathumthani, 12120 Thailand.
| |
Collapse
|
29
|
Gholami MD, O'Mullane AP, Sonar P, Ayoko GA, Izake EL. Antibody coated conductive polymer for the electrochemical immunosensing of Human Cardiac Troponin I in blood plasma. Anal Chim Acta 2021; 1185:339082. [PMID: 34711328 DOI: 10.1016/j.aca.2021.339082] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Revised: 09/15/2021] [Accepted: 09/16/2021] [Indexed: 01/05/2023]
Abstract
Cardiac troponin I (cTnI) is a sensitive biomarker for cardiovascular disease (CVD). Rapid determination of cTnI concentration in blood can greatly reduce the potential of significant heart damage and heart failure. Herein, we demonstrate a new electrochemical immunosensor for selective affinity binding and rapid detection of cTnI in blood plasma by an electrochemical method. A conductive film of "poly 2,5-bis(2-thienyl)3,4-diamine-terthiophene (PDATT)" was deposited onto an Indium Tin Oxide (ITO) electrode using chronoamperometry. Anti-cardiac troponin I antibody was then attached to the two amine (NH2) groups substituted on the central thiophene of terthiophene repeating unit of the polymer chain via amide bond formation. The gaps on the surface of the antibody coated immunosensor were backfilled with bovine serum albumin (BSA) to prevent nonspecific binding of interfering molecules. Differential pulse voltammetry (DPV) was used to determine cTnI upon the formation of cTnI immunocomplex on the sensing surface, appearing a peak at 0.27 V. The response range was 0.01-100 ng mL-1 with limit of quantification down to 0.01 ng mL-1. The developed immunosensor was used to determine cTnI in spiked blood plasma without interference from cardiac troponin T (cTnT). Therefore, this new sensor can be utilised for the detection of cTnI biomarker in pathological laboratories and points of care in less than 15 min.
Collapse
Affiliation(s)
- Mahnaz D Gholami
- School of Chemistry and Physics, Faculty of Science, Queensland University of Technology (QUT), 2 George Street, Brisbane, QLD, 4000, Australia
| | - Anthony P O'Mullane
- School of Chemistry and Physics, Faculty of Science, Queensland University of Technology (QUT), 2 George Street, Brisbane, QLD, 4000, Australia; Centre for Materials Science, Queensland University of Technology (QUT), 2 George Street, Brisbane, QLD, 4000, Australia.
| | - Prashant Sonar
- School of Chemistry and Physics, Faculty of Science, Queensland University of Technology (QUT), 2 George Street, Brisbane, QLD, 4000, Australia; Centre for Materials Science, Queensland University of Technology (QUT), 2 George Street, Brisbane, QLD, 4000, Australia
| | - Godwin A Ayoko
- School of Chemistry and Physics, Faculty of Science, Queensland University of Technology (QUT), 2 George Street, Brisbane, QLD, 4000, Australia; Centre for Materials Science, Queensland University of Technology (QUT), 2 George Street, Brisbane, QLD, 4000, Australia
| | - Emad L Izake
- School of Chemistry and Physics, Faculty of Science, Queensland University of Technology (QUT), 2 George Street, Brisbane, QLD, 4000, Australia; Centre for Materials Science, Queensland University of Technology (QUT), 2 George Street, Brisbane, QLD, 4000, Australia.
| |
Collapse
|
30
|
Thapa K, Liu W, Wang R. Nucleic acid-based electrochemical biosensor: Recent advances in probe immobilization and signal amplification strategies. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2021; 14:e1765. [PMID: 34734485 DOI: 10.1002/wnan.1765] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 08/06/2021] [Accepted: 10/04/2021] [Indexed: 12/26/2022]
Abstract
With the increasing importance of accurate and early disease diagnosis and the development of personalized medicine, DNA-based electrochemical biosensor has attracted broad scientific and clinical interests in the past decades due to its unique hybridization specificity, fast response time, and potential for miniaturization. In order to achieve high detection sensitivity, the design of DNA electrochemical biosensors depends critically on the improvement of the accessibility of target molecules and the enhancement of signal readout. Here, we summarize the recent advances in DNA probe immobilization and signal amplification strategies with a special focus on DNA nanostructure-supported DNA probe immobilization method, which provides the opportunity to rationally control the distance between probes and keep them in upright confirmation, as well as the contribution of functional nanomaterials in enhancing the signal amplification. The next challenge of biosensors will be the fabrication of point-of-care devices for clinical testing. The advancement of multidisciplinary areas, including nanofabrication, material science, and biochemistry, has exhibited profound promise in achieving such portable sensing devices. This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > Diagnostic Nanodevices Biology-Inspired Nanomaterials > Nucleic Acid-Based Structures.
Collapse
Affiliation(s)
- Krishna Thapa
- Department of Chemistry, Missouri University of Science and Technology, Rolla, Missouri, USA
| | - Wenyan Liu
- Department of Chemistry, Missouri University of Science and Technology, Rolla, Missouri, USA.,Center for Research in Energy and Environment, Missouri University of Science and Technology, Rolla, Missouri, USA
| | - Risheng Wang
- Department of Chemistry, Missouri University of Science and Technology, Rolla, Missouri, USA
| |
Collapse
|
31
|
Kalkan Z, Yence M, Turk F, Bektas TU, Ozturk S, Surdem S, Yildirim‐Tirgil N. Boronic Acid Substituted Polyaniline Based Enzymatic Biosensor System for Catechol Detection. ELECTROANAL 2021. [DOI: 10.1002/elan.202100271] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Zeycan Kalkan
- Materials Engineering Faculty of Engineering and Natural Sciences Ankara Yıldırım Beyazıt University Ankara Turkey
| | - Merve Yence
- TENMAK Boron Research Institute Ankara Turkey
| | - Fatih Turk
- Materials Engineering Faculty of Engineering and Natural Sciences Ankara Yıldırım Beyazıt University Ankara Turkey
| | - Tamer U. Bektas
- Materials Engineering Faculty of Engineering and Natural Sciences Ankara Yıldırım Beyazıt University Ankara Turkey
| | | | | | - Nimet Yildirim‐Tirgil
- Materials Engineering Faculty of Engineering and Natural Sciences Ankara Yıldırım Beyazıt University Ankara Turkey
- Biomedical Engineering Faculty of Engineering and Natural Sciences Ankara Yıldırım Beyazıt University Ankara Turkey
| |
Collapse
|
32
|
Cheema JA, Carraher C, Plank NOV, Travas-Sejdic J, Kralicek A. Insect odorant receptor-based biosensors: Current status and prospects. Biotechnol Adv 2021; 53:107840. [PMID: 34606949 DOI: 10.1016/j.biotechadv.2021.107840] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 09/02/2021] [Accepted: 09/27/2021] [Indexed: 02/01/2023]
Abstract
Whilst the senses of vision and hearing have been successfully automated and miniaturized in portable formats (e.g. smart phone), this is yet to be achieved with the sense of smell. This is because the sensing challenge is not trivial as it involves navigating a chemosensory space comprising thousands of volatile organic compounds. Distinct aroma recognition is based on detecting unique combinations of volatile organic compounds. In natural olfactory systems this is accomplished by employing odorant receptors (ORs) with varying specificities, together with combinatorial neural coding mechanisms. Attempts to mimic the remarkable sensitivity and accuracy of natural olfactory systems has therefore been challenging. Current portable chemical sensors for odorant detection are neither sensitive nor selective, prompting research exploring artificial olfactory devices that use natural OR proteins for sensing. Much research activity to develop OR based biosensors has concentrated on mammalian ORs, however, insect ORs have not been explored as extensively. Insects possess an extraordinary sense of smell due to a repertoire of odorant receptors evolved to interpret olfactory cues vital to the insects' survival. The potential of insect ORs as sensing elements is only now being unlocked through recent research efforts to understand their structure, ligand binding mechanisms and development of odorant biosensors. Like their mammalian counterparts, there are many challenges with working with insect ORs. These include expression, purification and presentation of the insect OR in a stable display format compatible with an effective transduction methodology while maintaining OR structure and function. Despite these challenges, significant progress has been demonstrated in developing OR-based biosensors which exploit insect ORs in cells, lipid bilayers, liposomes and nanodisc formats. Ultrasensitive and highly selective detection of volatile organic compounds has been validated by coupling these insect OR display formats with transduction methodologies spanning optical (fluorescence) and electrical (field effect transistors, electrochemical impedance spectroscopy) techniques. This review summarizes the current status of insect OR based biosensors and their future outlook.
Collapse
Affiliation(s)
- Jamal Ahmed Cheema
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1023, New Zealand; MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington 6140, New Zealand; The New Zealand Institute for Plant and Food Research Limited, Private Bag 92169, Auckland 1142, New Zealand
| | - Colm Carraher
- The New Zealand Institute for Plant and Food Research Limited, Private Bag 92169, Auckland 1142, New Zealand
| | - Natalie O V Plank
- MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington 6140, New Zealand; School of Chemical and Physical Sciences, Victoria University of Wellington, Wellington 6021, New Zealand
| | - Jadranka Travas-Sejdic
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1023, New Zealand; MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington 6140, New Zealand.
| | - Andrew Kralicek
- The New Zealand Institute for Plant and Food Research Limited, Private Bag 92169, Auckland 1142, New Zealand; Scentian Bio Limited, 1c Goring Road, Sandringham, Auckland 1025, New Zealand.
| |
Collapse
|
33
|
Zia TUH, Ali Shah AUH. Understanding the adsorption of 1 NLB antibody on polyaniline nanotubes as a function of zeta potential and surface charge density for detection of hepatitis C core antigen: A label-free impedimetric immunosensor. Colloids Surf A Physicochem Eng Asp 2021. [DOI: 10.1016/j.colsurfa.2021.127076] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
34
|
A Cu2O/PEDOT/graphene-modified electrode for the enzyme-free detection and quantification of glucose. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115558] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
35
|
Shiohara A, Prieto-Simon B, Voelcker NH. Porous polymeric membranes: fabrication techniques and biomedical applications. J Mater Chem B 2021; 9:2129-2154. [PMID: 33283821 DOI: 10.1039/d0tb01727b] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Porous polymeric membranes have shown great potential in biological and biomedical applications such as tissue engineering, bioseparation, and biosensing, due to their structural flexibility, versatile surface chemistry, and biocompatibility. This review outlines the advantages and limitations of the fabrication techniques commonly used to produce porous polymeric membranes, with especial focus on those featuring nano/submicron scale pores, which include track etching, nanoimprinting, block-copolymer self-assembly, and electrospinning. Recent advances in membrane technology have been key to facilitate precise control of pore size, shape, density and surface properties. The review provides a critical overview of the main biological and biomedical applications of these porous polymeric membranes, especially focusing on drug delivery, tissue engineering, biosensing, and bioseparation. The effect of the membrane material and pore morphology on the role of the membranes for each specific application as well as the specific fabrication challenges, and future prospects of these membranes are thoroughly discussed.
Collapse
Affiliation(s)
- Amane Shiohara
- Drug Delivery, Deposition, and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia. and Commonwealth Scientific and Industrial Research Organisation (CSIRO), Clayton, Victoria 3168, Australia and Melbourne Centre of Nanofabrication, Victorian Node of the Australian National Fabrication Facility, Clayton, Victoria 3168, Australia
| | - Beatriz Prieto-Simon
- Drug Delivery, Deposition, and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia. and Department of Electronic Engineering, Universitat Rovira i Virgili, 43007 Tarragona, Spain and ICREA, Pg. Lluís Companys 23, 08010 Barcelona, Spain
| | - Nicolas H Voelcker
- Drug Delivery, Deposition, and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia. and Commonwealth Scientific and Industrial Research Organisation (CSIRO), Clayton, Victoria 3168, Australia and Melbourne Centre of Nanofabrication, Victorian Node of the Australian National Fabrication Facility, Clayton, Victoria 3168, Australia
| |
Collapse
|
36
|
Hassan MH, Vyas C, Grieve B, Bartolo P. Recent Advances in Enzymatic and Non-Enzymatic Electrochemical Glucose Sensing. SENSORS (BASEL, SWITZERLAND) 2021; 21:4672. [PMID: 34300412 PMCID: PMC8309655 DOI: 10.3390/s21144672] [Citation(s) in RCA: 84] [Impact Index Per Article: 28.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 06/28/2021] [Accepted: 07/06/2021] [Indexed: 11/17/2022]
Abstract
The detection of glucose is crucial in the management of diabetes and other medical conditions but also crucial in a wide range of industries such as food and beverages. The development of glucose sensors in the past century has allowed diabetic patients to effectively manage their disease and has saved lives. First-generation glucose sensors have considerable limitations in sensitivity and selectivity which has spurred the development of more advanced approaches for both the medical and industrial sectors. The wide range of application areas has resulted in a range of materials and fabrication techniques to produce novel glucose sensors that have higher sensitivity and selectivity, lower cost, and are simpler to use. A major focus has been on the development of enzymatic electrochemical sensors, typically using glucose oxidase. However, non-enzymatic approaches using direct electrochemistry of glucose on noble metals are now a viable approach in glucose biosensor design. This review discusses the mechanisms of electrochemical glucose sensing with a focus on the different generations of enzymatic-based sensors, their recent advances, and provides an overview of the next generation of non-enzymatic sensors. Advancements in manufacturing techniques and materials are key in propelling the field of glucose sensing, however, significant limitations remain which are highlighted in this review and requires addressing to obtain a more stable, sensitive, selective, cost efficient, and real-time glucose sensor.
Collapse
Affiliation(s)
- Mohamed H. Hassan
- Department of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester M13 9PL, UK; (M.H.H.); (C.V.)
| | - Cian Vyas
- Department of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester M13 9PL, UK; (M.H.H.); (C.V.)
| | - Bruce Grieve
- Department of Electrical & Electronic Engineering, University of Manchester, Manchester M13 9PL, UK;
| | - Paulo Bartolo
- Department of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester M13 9PL, UK; (M.H.H.); (C.V.)
| |
Collapse
|
37
|
Ajmal Mokhtar SM, Alvarez de Eulate E, Sethumadhavan V, Yamada M, Prow TW, Evans DR. Electrochemical stability of
PEDOT
for wearable
on‐skin
application. J Appl Polym Sci 2021. [DOI: 10.1002/app.51314] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Siti Musliha Ajmal Mokhtar
- Future Industries Institute University of South Australia Mawson Lakes Australia
- Faculty of Electrical Engineering Universiti Teknologi Mara, Johor Branch, Pasir Gudang Campus Masai Malaysia
| | | | | | - Miko Yamada
- Future Industries Institute University of South Australia Mawson Lakes Australia
| | - Tarl W. Prow
- Future Industries Institute University of South Australia Mawson Lakes Australia
| | - Drew R. Evans
- Future Industries Institute University of South Australia Mawson Lakes Australia
| |
Collapse
|
38
|
A New Nanomaterial Based Biosensor for MUC1 Biomarker Detection in Early Diagnosis, Tumor Progression and Treatment of Cancer. ACTA ACUST UNITED AC 2021. [DOI: 10.3390/nanomanufacturing1010003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Early detection of cancer disease is vital to the successful treatment, follow-up and survival of patients, therefore sensitive and specific methods are still required. Mucin 1 (MUC1) is a clinically approved biomarker for determining the cancer that is a type I transmembrane protein with a dense glycosylated extracellular domain extending from the cell surface to 200–500 nm. In this study, nanopolymers were designed with a lectin affinity-based recognition system for MUC1 detection as a bioactive layer on electrochemical biosensor electrode surfaces. They were synthesized using a mini emulsion polymerization method and derivatized with triethoxy-3-(2-imidazolin-1-yl) propylsilane (IMEO) and functionalized with Concanavalin a Type IV (Con A) lectin. Advanced characterization studies of nanopolymers were performed. The operating conditions of the sensor system have been optimized. Biosensor validation studies were performed. Real sample blood serum was analyzed and this new method compared with a commercially available medical diagnostic kit (Enzyme-Linked ImmunoSorbent Assay-ELISA). The new generation nanopolymeric material has been shown to be an affordable, sensitive, reliable and rapid device with 0.1–100 U/mL linear range and 20 min response time.
Collapse
|
39
|
Dalkiran B, Brett CMA. Polyphenazine and polytriphenylmethane redox polymer/nanomaterial-based electrochemical sensors and biosensors: a review. Mikrochim Acta 2021; 188:178. [PMID: 33913010 DOI: 10.1007/s00604-021-04821-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Accepted: 04/02/2021] [Indexed: 12/01/2022]
Abstract
In recent years, an increasing number of studies has demonstrated that redox polymers can be used in simple and effective electrochemical sensing platforms due to their fast electron transfer and electrocatalytic ability. To develop more sensitive and selective electrochemical (bio)sensors, the electrocatalytic properties of redox polymers and the electrical, mechanical, and catalytic properties of various nanomaterials are combined. This review aims to summarize and contribute to the development of (bio)sensors based on polyphenazine or polytriphenylmethane redox polymers combined with nanomaterials, including carbon-based nanomaterials, metal/metal oxide, and semiconductor nanoparticles. The synthesis, preparation, and modification of these nanocomposites is presented and the contribution of each material to the performance of (bio)sensor has been be examined. It is explained how the combined use of these redox polymers and nanomaterials as a sensing platform leads to improved analytical performance of the (bio)sensors. Finally, the analytical performance characteristics and practical applications of polyphenazine and polytriphenylmethane redox polymer/nanomaterial-based electrochemical (bio)sensors are compared and discussed.
Collapse
Affiliation(s)
- Berna Dalkiran
- Department of Chemistry, University of Coimbra, CEMMPRE, 3004-535, Coimbra, Portugal.,Department of Chemistry, Faculty of Science, Ankara University, 06100, Ankara, Turkey
| | - Christopher M A Brett
- Department of Chemistry, University of Coimbra, CEMMPRE, 3004-535, Coimbra, Portugal.
| |
Collapse
|
40
|
Shu T, Hu L, Shen Q, Jiang L, Zhang Q, Serpe MJ. Stimuli-responsive polymer-based systems for diagnostic applications. J Mater Chem B 2021; 8:7042-7061. [PMID: 32743631 DOI: 10.1039/d0tb00570c] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Stimuli-responsive polymers exhibit properties that make them ideal candidates for biosensing and molecular diagnostics. Through rational design of polymer composition combined with new polymer functionalization and synthetic strategies, polymers with myriad responsivities, e.g., responses to temperature, pH, biomolecules, CO2, light, and electricity can be achieved. When these polymers are specifically designed to respond to biomarkers, stimuli-responsive devices/probes, capable of recognizing and transducing analyte signals, can be used to diagnose and treat disease. In this review, we highlight recent state-of-the-art examples of stimuli-responsive polymer-based systems for biosensing and bioimaging.
Collapse
Affiliation(s)
- Tong Shu
- School of Biomedical Engineering, Shenzhen University Health Science Center, Shenzhen, Guangdong 518060, China
| | - Liang Hu
- State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, 199 Ren'ai Road, Suzhou 215123, China
| | - Qiming Shen
- Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2, Canada.
| | - Li Jiang
- State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, 199 Ren'ai Road, Suzhou 215123, China
| | - Qiang Zhang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, China.
| | - Michael J Serpe
- Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2, Canada.
| |
Collapse
|
41
|
Tang J, Xie T, Geng J, Hua J, Wang Z. Rearrangement Strategy for the Preparation of Polymers With π-Conjugated Structures. Front Chem 2021; 9:665877. [PMID: 33869147 PMCID: PMC8049560 DOI: 10.3389/fchem.2021.665877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 03/01/2021] [Indexed: 11/22/2022] Open
Abstract
π-Conjugated polymers are usually prepared by polymerization only. In this perspective article, typical synthesis methods of conjugated polymers are briefly summarized, and a novel strategy for preparing conjugated polymers by rearrangement is proposed. During the metalation process, many conjugated structures were generated in polybutadiene by double bond migration. The effects of reaction time, temperature, and catalyst dosage on the product structure were investigated. Moreover, the structure of the products was confirmed by FTIR, 1H NMR, and 2D HSQC NMR spectra. Thus, a possible reaction mechanism was proposed, in which polybutadiene generates allylic carbanions in the presence of n-butyllithium, and then the double bonds migrate through the carbanions rearrangement to generate many conjugated structures in the backbone chain. The method shows promise in facile and low-cost synthesis of conjugated polymers without the need for precious metal catalysts.
Collapse
Affiliation(s)
| | - Tinghao Xie
- Key Laboratory of Rubber-Plastics, Ministry of Education, Shandong Education, Shandong Provincial Key Laboratory of Rubber-plastics, Qingdao University of Science and Technology, Qingdao, China
| | | | - Jing Hua
- Key Laboratory of Rubber-Plastics, Ministry of Education, Shandong Education, Shandong Provincial Key Laboratory of Rubber-plastics, Qingdao University of Science and Technology, Qingdao, China
| | - Zhaobo Wang
- Key Laboratory of Rubber-Plastics, Ministry of Education, Shandong Education, Shandong Provincial Key Laboratory of Rubber-plastics, Qingdao University of Science and Technology, Qingdao, China
| |
Collapse
|
42
|
Tran VV, Tran NHT, Hwang HS, Chang M. Development strategies of conducting polymer-based electrochemical biosensors for virus biomarkers: Potential for rapid COVID-19 detection. Biosens Bioelectron 2021; 182:113192. [PMID: 33819902 PMCID: PMC7992312 DOI: 10.1016/j.bios.2021.113192] [Citation(s) in RCA: 39] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 03/16/2021] [Accepted: 03/18/2021] [Indexed: 12/24/2022]
Abstract
Rapid, accurate, portable, and large-scale diagnostic technologies for the detection of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) are crucial for controlling the coronavirus disease (COVID-19). The current standard technologies, i.e., reverse-transcription polymerase chain reaction, serological assays, and computed tomography (CT) exhibit practical limitations and challenges in case of massive and rapid testing. Biosensors, particularly electrochemical conducting polymer (CP)-based biosensors, are considered as potential alternatives owing to their large advantages such as high selectivity and sensitivity, rapid detection, low cost, simplicity, flexibility, long self-life, and ease of use. Therefore, CP-based biosensors can serve as multisensors, mobile biosensors, and wearable biosensors, facilitating the development of point-of-care (POC) systems and home-use biosensors for COVID-19 detection. However, the application of these biosensors for COVID-19 entails several challenges related to their degradation, low crystallinity, charge transport properties, and weak interaction with biomarkers. To overcome these problems, this study provides scientific evidence for the potential applications of CP-based electrochemical biosensors in COVID-19 detection based on their applications for the detection of various biomarkers such as DNA/RNA, proteins, whole viruses, and antigens. We then propose promising strategies for the development of CP-based electrochemical biosensors for COVID-19 detection.
Collapse
Affiliation(s)
- Vinh Van Tran
- Alan G. MacDiarmid Energy Research Institute, Chonnam National University, Gwangju 61186, South Korea
| | - Nhu Hoa Thi Tran
- Faculty of Materials Science and Technology, University of Science, HoChiMinh City 700000, Viet Nam; Vietnam National University, HoChiMinh City 700000, Viet Nam
| | - Hye Suk Hwang
- Alan G. MacDiarmid Energy Research Institute, Chonnam National University, Gwangju 61186, South Korea.
| | - Mincheol Chang
- Alan G. MacDiarmid Energy Research Institute, Chonnam National University, Gwangju 61186, South Korea; Department of Polymer Engineering, Graduate School, Chonnam National University, Gwangju 61186, South Korea; School of Polymer Science and Engineering, Chonnam National University, Gwangju 61186, South Korea.
| |
Collapse
|
43
|
Nanda O, Gupta N, Biradar A, Saxena K. Effect of Humidity on the Electrical Properties of Poly (3, 4‐Ethylenedioxythiophene) – Poly (Styrenesulfonate) and its Carbon Nanotube Composites. ChemistrySelect 2021. [DOI: 10.1002/slct.202004311] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Omita Nanda
- Amity Institute of Renewable and Alternative Energy & Amity Institute of Advanced Research and Studies (Materials and Devices) Amity University Uttar Pradesh, Sector 125 Noida, U.P. 201313 India
| | - Nidhi Gupta
- Amity Institute of Renewable and Alternative Energy & Amity Institute of Advanced Research and Studies (Materials and Devices) Amity University Uttar Pradesh, Sector 125 Noida, U.P. 201313 India
| | - Ashok M. Biradar
- CSIR-National Physical Laboratory Dr. K. S. Krishnan Road New Delhi 110012 India
| | - Kanchan Saxena
- Amity Institute of Renewable and Alternative Energy & Amity Institute of Advanced Research and Studies (Materials and Devices) Amity University Uttar Pradesh, Sector 125 Noida, U.P. 201313 India
| |
Collapse
|
44
|
Electrosynthesis of polydopamine-ethanolamine films for the development of immunosensing interfaces. Sci Rep 2021; 11:2237. [PMID: 33500469 PMCID: PMC7838280 DOI: 10.1038/s41598-021-81816-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Accepted: 11/26/2020] [Indexed: 12/21/2022] Open
Abstract
We report a straightforward and reproducible electrochemical approach to develop polydopamine-ethanolamine (ePDA-ETA) films to be used as immunosensing interfaces. ETA is strongly attached to polydopamine films during the potentiodynamic electropolymerization of dopamine. The great advantage of the electrochemical methods is to generate the oxidized species (quinones), which can readily react with ETA amine groups present in solution, with the subsequent incorporation of this molecule in the polymer. The presence of ETA and its effect on the electrosynthesis of polydopamine was accessed by cyclic voltammetry, ellipsometry, atomic force microscopy, FTIR and X-ray photoelectron spectroscopy. The adhesive and biocompatible films enable a facile protein linkage, are resilient to flow assays, and display intrinsic anti-fouling properties to block non-specific protein interactions, as monitored by real-time surface plasmon resonance, and confirmed by ellipsometry. Immunoglobulin G (IgG) and Anti-IgG were used in this work as model proteins for the affinity sensor. By using the one-step methodology (ePDA-ETA), the lower amount of immobilized biorecognition element, IgG, compared to that deposited on ePDA or on ETA post-modified film (ePDA/ETA), allied to the presence of ETA, improved the antibody-antigen affinity interaction. The great potential of the developed platform is its versatility to be used with any target biorecognition molecules, allowing both optical and electrochemical detection.
Collapse
|
45
|
Uzunçar S, Meng L, Turner AP, Mak WC. Processable and nanofibrous polyaniline:polystyrene-sulphonate (nano-PANI:PSS) for the fabrication of catalyst-free ammonium sensors and enzyme-coupled urea biosensors. Biosens Bioelectron 2021; 171:112725. [DOI: 10.1016/j.bios.2020.112725] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Revised: 09/28/2020] [Accepted: 10/12/2020] [Indexed: 12/15/2022]
|
46
|
Gelen SS, Munkhbat T, Rexhepi Z, Kirbay FO, Azak H, Demirkol DO. Catalase-conjugated surfaces: H2O2 detection based on quenching of tryptophan fluorescence on conducting polymers. Eur Polym J 2021. [DOI: 10.1016/j.eurpolymj.2020.110130] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
47
|
Wu J, Zhu Y, You L, Dong PT, Mei J, Cheng JX. Polymer Electrochromism Driven by Metabolic Activity Facilitates Rapid and Facile Bacterial Detection and Susceptibility Evaluation. ADVANCED FUNCTIONAL MATERIALS 2020; 30:2005192. [PMID: 33708032 PMCID: PMC7941207 DOI: 10.1002/adfm.202005192] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Indexed: 05/19/2023]
Abstract
The electrochromism of a water-soluble naturally oxidized electrochromic polymer, ox-PPE, is harnessed for rapid and facile bacterial detection, discrimination, and susceptibility testing. The ox-PPE solution shows distinct colorimetric and spectroscopic changes within 30 min when mixed with live bacteria. For the underlying mechanism, it is found that ox-PPE responds to the reducing species (e.g. cysteine and glutathione) released by metabolically active bacteria. This reduction reaction is ubiquitous among various bacterial strains, with a noticeable difference that enables discrimination of Gram-negative and Gram-positive bacterial strains. Combining ox-PPE with antibiotics, methicillin-susceptible and -resistant S. aureus can be differentiated within 2.5 h. Proof-of-concept demonstration of ox-PPE for antimicrobial susceptibility testing is carried out by incubating E. coli with various antibiotics. The obtained minimum inhibition concentrations are consistent with the conventional culture-based methods, but with the procedure time significantly shortened to 3 h.
Collapse
Affiliation(s)
- Jiayingzi Wu
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, USA
| | - Yifan Zhu
- Department of Chemistry, Department of Electrical and Computer Engineering, Boston University, Boston, Massachusetts 02215, USA
| | - Liyan You
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, USA
| | - Pu-Ting Dong
- Department of Chemistry, Department of Electrical and Computer Engineering, Boston University, Boston, Massachusetts 02215, USA
| | - Jianguo Mei
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, USA
| | - Ji-Xin Cheng
- Department of Chemistry, Department of Electrical and Computer Engineering, Boston University, Boston, Massachusetts 02215, USA; Department of Physics, Department of Biomedical Engineering, Boston University, Boston, Massachusetts 02215, USA
| |
Collapse
|
48
|
Bakirhan NK, Topal BD, Ozcelikay G, Karadurmus L, Ozkan SA. Current Advances in Electrochemical Biosensors and Nanobiosensors. Crit Rev Anal Chem 2020; 52:519-534. [DOI: 10.1080/10408347.2020.1809339] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Nurgul K. Bakirhan
- Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Ankara, Turkey
| | - Burcu D. Topal
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Goksu Ozcelikay
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Leyla Karadurmus
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
- Department of Analytical Chemistry, Faculty of Pharmacy, Adıyaman University, Adıyaman, Turkey
| | - Sibel A. Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
49
|
Khokhar D, Jadoun S, Arif R, Jabin S. Functionalization of conducting polymers and their applications in optoelectronics. POLYM-PLAST TECH MAT 2020. [DOI: 10.1080/25740881.2020.1819312] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Deepali Khokhar
- Department of Chemistry, Lingaya’s Vidyapeeth, Faridabad, India
| | - Sapana Jadoun
- Department of Chemistry, Lingaya’s Vidyapeeth, Faridabad, India
| | - Rizwan Arif
- Department of Chemistry, Lingaya’s Vidyapeeth, Faridabad, India
| | - Shagufta Jabin
- Department of Chemistry, Manav Rachna International Institute of Research & Studies, Faridabad, India
| |
Collapse
|
50
|
Ito RM, de Souza CC, Gandarilla AMD, de Oliveira LM, Brito WR, Sanches EA, Matos RS, da Fonseca Filho HD. Micromorphology and microtexture evaluation of poly(o-ethoxyaniline) films using atomic force microscopy and fractal analysis. JOURNAL OF POLYMER RESEARCH 2020. [DOI: 10.1007/s10965-020-02262-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|