1
|
Guliya H, Yadav M, Nohwal B, Lata S, Chaudhary R. Emphasizing laccase based amperometric biosensing as an eventual panpharmacon for rapid and effective detection of phenolic compounds. Biochim Biophys Acta Gen Subj 2024; 1868:130691. [PMID: 39117046 DOI: 10.1016/j.bbagen.2024.130691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Accepted: 08/05/2024] [Indexed: 08/10/2024]
Abstract
Phenols and phenolic compounds are major plant metabolites used in industries to produce pesticides, dyes, medicines, and plastics. These compounds enter water bodies, soil, and living organisms via such industrial routes. Some polyphenolic compounds like phenolic acids, flavonoids have antioxidant and organoleptic qualities, as well as preventive effects against neurodegenerative illnesses, cardiovascular disease, diabetes, and cancer. However, many of the polyphenolic compounds, such as Bisphenol A, phthalates, and dioxins also cause major environmental pollution and endocrine disruption, once the dose level becomes objectionable. The development of reliable and rapid methods for studying their dose dependency, high-impact detrimental effects, and continuous monitoring of phenol levels in humans and environmental samples is a crucial necessity of the day. Enzymatic biosensors employing phenol oxidases like tyrosinase, peroxidase and laccase, utilizing electrochemical amperometric methods are innovative methods for phenol quantification. Enzymatic biosensing, being highly sensitive and efficacious technique, is illuminated in this review article as a progressive approach for phenol quantification with special emphasis on laccase amperometric biosensors. Even more, the review article discussion is extended up to nanozymes, composites of metal organic frameworks (MOFs), and molecularly imprinted polymers (MIPs) as some emerging species for electro-chemical sensing of phenols. Applications of phenol quantification and green biosensing are also specified. A concrete summary of the innovative polyphenol detection approaches with futuristic scope indicates a triumph over some existing constraints of the phenomenological approaches providing an informative aisle to the modern researchers towards the bulk readability.
Collapse
Affiliation(s)
- Himani Guliya
- Department of Biotechnology, Deenbandhu Chhotu Ram University of Science and Technology, Murth, al-131039, Haryana, India
| | - Meena Yadav
- Department of Chemistry, Deenbandhu Chhotu Ram University of Science and Technology, Murth, al-131039, Haryana, India
| | - Bhawna Nohwal
- Department of Biotechnology, Deenbandhu Chhotu Ram University of Science and Technology, Murth, al-131039, Haryana, India
| | - Suman Lata
- Department of Chemistry, Deenbandhu Chhotu Ram University of Science and Technology, Murth, al-131039, Haryana, India.
| | - Reeti Chaudhary
- Department of Biotechnology, Deenbandhu Chhotu Ram University of Science and Technology, Murth, al-131039, Haryana, India.
| |
Collapse
|
2
|
Savas S, Sarıçam M. A Novel PCR-Free Ultrasensitive GQD-Based Label-Free Electrochemical DNA Sensor for Sensitive and Rapid Detection of Francisella tularensis. MICROMACHINES 2024; 15:1308. [PMID: 39597120 PMCID: PMC11596170 DOI: 10.3390/mi15111308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2024] [Revised: 10/21/2024] [Accepted: 10/24/2024] [Indexed: 11/29/2024]
Abstract
Biological warfare agents are infectious microorganisms or toxins capable of harming or killing humans. Francisella tularensis is a potential bioterrorism agent that is highly infectious, even at very low doses. Biosensors for biological warfare agents are simple yet reliable point-of-care analytical tools. Developing highly sensitive, reliable, and cost-effective label-free DNA biosensors poses significant challenges, particularly when utilizing traditional techniques such as fluorescence, electrochemical methods, and others. These challenges arise primarily due to the need for labeling, enzymes, or complex modifications, which can complicate the design and implementation of biosensors. In this study, we fabricated Graphene Quantum dot (GQD)-functionalized biosensors for highly sensitive label-free DNA detection. GQDs were immobilized on the surface of screen-printed gold electrodes via mercaptoacetic acid with a thiol group. The single-stranded DNA (ssDNA) probe was also immobilized on GQDs through strong π-π interactions. The ssDNA probe can hybridize with the ssDNA target and form double-stranded DNA, leading to a decrease in the effect of GQD but a positive shift associated with the increase in DNA concentration. The specificity of the developed system was observed with different microorganism target DNAs and up to three-base mismatches in the target DNA, effectively distinguishing the target DNA. The response time for the target DNA molecule is approximately 1010 s (17 min). Experimental steps were monitored using UV/Vis spectroscopy, Atomic Force Microscopy (AFM), and electrochemical techniques to confirm the successful fabrication of the biosensor. The detection limit can reach 0.1 nM, which is two-five orders of magnitude lower than previously reported methods. The biosensor also exhibits a good linear range from 105 to 0.01 nM and has good specificity. The biosensor's detection limit (LOD) was evaluated as 0.1 nM from the standard calibration curve, with a correlation coefficient of R2 = 0.9712, showing a good linear range and specificity. Here, we demonstrate a cost-effective, GQD-based SPGE/F. tularensis DNA test suitable for portable electrochemical devices. This application provides good perspectives for point-of-care portable electrochemical devices that integrate sample processing and detection into a single cartridge without requiring a PCR before detection. Based on these results, it can be concluded that this is the first enzyme-free electrochemical DNA biosensor developed for the rapid and sensitive detection of F. tularensis, leveraging the nanoenzyme and catalytic properties of GQDs.
Collapse
Affiliation(s)
- Sumeyra Savas
- Department of Clinical Microbiology, Medical School, Bandirma Onyedi Eylul University, Bandırma 10200, Türkiye
| | - Melike Sarıçam
- CBRN Defense Technologies R&D Group, Materials and Process Technologies, The Scientific and Technological Research Council of Türkiye (TÜBİTAK), Marmara Research Center, Kocaeli 41470, Türkiye;
| |
Collapse
|
3
|
Walimbe PD, Kumar R, Shringi AK, Keelson O, Ouma HA, Yan F. Electrochemical Detection of H 2O 2 Using Bi 2O 3/Bi 2O 2Se Nanocomposites. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:1592. [PMID: 39404320 PMCID: PMC11478603 DOI: 10.3390/nano14191592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2024] [Revised: 09/25/2024] [Accepted: 09/27/2024] [Indexed: 10/19/2024]
Abstract
The development of high-performance hydrogen peroxide (H2O2) sensors is critical for various applications, including environmental monitoring, industrial processes, and biomedical diagnostics. This study explores the development of efficient and selective H2O2 sensors based on bismuth oxide/bismuth oxyselenide (Bi2O3/Bi2O2Se) nanocomposites. The Bi2O3/Bi2O2Se nanocomposites were synthesized using a simple solution-processing method at room temperature, resulting in a unique heterostructure with remarkable electrochemical characteristics for H2O2 detection. Characterization techniques, including powder X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM), confirmed the successful formation of the nanocomposites and their structural integrity. The synthesis time was varied to obtain the composites with different Se contents. The end goal was to obtain phase pure Bi2O2Se. Electrochemical measurements revealed that the Bi2O3/Bi2O2Se composite formed under optimal synthesis conditions displayed high sensitivity (75.7 µA µM-1 cm-2) and excellent selectivity towards H2O2 detection, along with a wide linear detection range (0-15 µM). The superior performance is attributed to the synergistic effect between Bi2O3 and Bi2O2Se, enhancing electron transfer and creating more active sites for H2O2 oxidation. These findings suggest that Bi2O3/Bi2O2Se nanocomposites hold great potential as advanced H2O2 sensors for practical applications.
Collapse
Affiliation(s)
| | - Rajeev Kumar
- Department of Chemistry and Biochemistry, North Carolina Central University, Durham, NC 27707, USA; (P.D.W.); (A.K.S.); (O.K.); (H.A.O.)
| | | | | | | | - Fei Yan
- Department of Chemistry and Biochemistry, North Carolina Central University, Durham, NC 27707, USA; (P.D.W.); (A.K.S.); (O.K.); (H.A.O.)
| |
Collapse
|
4
|
Pourmadadi M, Ghaemi A, Khanizadeh A, Yazdian F, Mollajavadi Y, Arshad R, Rahdar A. Breast cancer detection based on cancer antigen 15-3; emphasis on optical and electrochemical methods: A review. Biosens Bioelectron 2024; 260:116425. [PMID: 38824703 DOI: 10.1016/j.bios.2024.116425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 04/23/2024] [Accepted: 05/23/2024] [Indexed: 06/04/2024]
Abstract
Cancer antigen 15-3 (CA 15-3) is a crucial marker used in the diagnosis and monitoring of breast cancer (BC). The demand for early and precise cancer detection has grown, making the creation of biosensors that are highly sensitive and specific essential. This review paper provides a thorough examination of the progress made in optical and electrochemical biosensors for detecting the cancer biomarker CA 15-3. We focus on explaining their fundamental principles, sensitivity, specificity, and potential for point-of-care applications. The performance attributes of these biosensors are assessed by considering their limits of detection, reaction times, and operational stability, while also making comparisons to conventional methods of CA 15-3 detection. In addition, we explore the incorporation of nanomaterials and innovative transducer components to improve the performance of biosensors. This paper conducts a thorough examination of recent studies to identify the existing obstacles. It also suggests potential areas for future research in this fast progressing field.The paper provides insights into their advancement and utilization to enhance patient outcomes. Both categories of biosensors provide significant promise for the detection of CA 15-3 and offer distinct advantages compared to conventional analytical approaches.
Collapse
Affiliation(s)
- Mehrab Pourmadadi
- Protein Research Center, Shahid Beheshti University, Tehran, GC, 1983963113, Iran
| | - Amirhossein Ghaemi
- Department of Biotechnology, School of Chemical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Amirhossein Khanizadeh
- Department of Biotechnology, School of Chemical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Fatemeh Yazdian
- Department of Life Science Engineering, Faculty of New Science and Technologies, University of Tehran, Tehran, Iran.
| | - Yasin Mollajavadi
- Department of Life Science Engineering, Faculty of New Science and Technologies, University of Tehran, Tehran, Iran
| | - Rabia Arshad
- Faculty of Pharmacy, The University of Lahore, Lahore, Pakistan; Adjunct Professor at Equator University of Science and Technology, Uganda
| | - Abbas Rahdar
- Department of Physics, Faculty of Sciences, University of Zabol, Zabol, 538-98615, Iran; Key Laboratory of Modeling and Simulation-based Reliability and Optimization, University of Zabol, Zabol, Iran.
| |
Collapse
|
5
|
Manasa G, Mahamiya V, Chakraborty B, Rout CS. 2D/1D VSe 2/MWCNT hybrid-based electrochemical sensor for carbendazim quantification of environmental, food, and biological samples. Mikrochim Acta 2024; 191:540. [PMID: 39150580 DOI: 10.1007/s00604-024-06619-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2024] [Accepted: 07/31/2024] [Indexed: 08/17/2024]
Abstract
For the first time the sensitive determination of carbendatim (CRB) is reported utilizing a well-designed sensing architecture based on vanadium diselenide-multiwalled carbon nanotube (VSMC). FTIR, XRD, FESEM, EDS, and EIS were employed to evaluate the sensor's structural integrity, and the results demonstrated the successful integration of nanomaterials, resulting in a robust and sensitive electrochemical sensor. Cyclic voltammetry (CV) and chronoamperometric (CA) investigations showed that the sensor best performed at pH 8.0 (BRB) with an excellent detection limit of 9.80 nM with a wide linear range of 0.1 to 10.0 µM. A more thermodynamically viable oxidation of CRB was observed at the VSMC/GCE, with a shift of 200 mV in peak potential towards the less positive side compared with the unmodified GCE. In addition, the sensor demonstrated facile heterogeneous electron transfer, favorable anti-fouling traits in the presence of a wide range of interferents, good stability, and reproducible analytical performance. Finally, the developed sensor was validated for real-time quantification of CRB from spiked water, food, and bio-samples, which depicted acceptable recoveries (98.6 to 101.5%) with RSD values between 0.35 and 2.23%. Further, to derive the possible sensing mechanism, the valence orbitals projected density of states (PDOS) for C, H, and N atoms of an isolated CRB molecule, VSe2 + CNT and VSe2 + CNT + CRB were calculated using density functional theory (DFT) calculations. The dominant charge transfer from the valence 2p-orbitals of the C and N atoms of CRB to CNT is responsible for the electrochemical sensing of CRB molecules.
Collapse
Affiliation(s)
- G Manasa
- Centre for Nano and Material Sciences, Jain (Deemed-to-Be University), Jain Global Campus, Kanakapura Road, Bangalore, 562112, Karnataka, India
| | - Vikram Mahamiya
- The Abdus Salam International Centre for Theoretical Physics (ICTP), Trieste, 34151, Italy
| | - Brahmananda Chakraborty
- High Pressure and Synchrotron Radiation Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India
- Homi Bhabha National Institute, Mumbai, 400094, India
| | - Chandra Sekhar Rout
- Centre for Nano and Material Sciences, Jain (Deemed-to-Be University), Jain Global Campus, Kanakapura Road, Bangalore, 562112, Karnataka, India.
| |
Collapse
|
6
|
Wang Z, Chen J, Ma H, Deng Y, Li Y, Geng L, Huang Y, Fan Y. A novel copper ion enhanced electrochemical DNA biosensor for the determination of epinephrine. Talanta 2024; 276:126274. [PMID: 38788379 DOI: 10.1016/j.talanta.2024.126274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 04/12/2024] [Accepted: 05/16/2024] [Indexed: 05/26/2024]
Abstract
A novel electrochemical biosensor was developed for the detection of epinephrine (EP) by immobilizing double-strand DNA (dsDNA) bound with copper ions on a gold electrode (Cu2+/dsDNA/MCH/AuE). The electrochemical behavior of EP at Cu2+/dsDNA/MCH/AuE was examined, and the results demonstrated a significant enhancement in the electrocatalytic oxidation peak current of EP due to the formation of a stable G-Cu(II)-G sandwich structure between Cu2+ and guanine at the modified electrode. The modification process of the electrode was characterized by scanning electron microscopy, infrared spectroscopy, electrochemical impedance spectroscopy, and differential pulse voltammetry. A study on the effect of pH in phosphate buffer solution on the electrochemical oxidation of EP indicated that the catalytic oxidation process was pH-dependent. A plot of catalytic current versus EP concentration exhibited a dual-linear relationship within two ranges: 1.0-12.5 μM and 12.5-1000.0 μM, with correlation coefficients of 0.995 and 0.997, respectively. The limit of detection was determined to be 47 nM (S/N = 3). According to the calculated Hill coefficient (0.99), it can be concluded that the electrocatalytic process followed the Michaelis-Menten kinetic mechanism. The maximum catalytic current Im was 25 μA, while the apparent Michaelis-Menten constant Km was 1.425 mM. These findings indicated excellent electrocatalytic activity of the modified electrode towards oxidation of EP. The developed biosensor successfully detected EP in spiked mouse serum as well as epinephrine hydrochloride injection with high selectivity, sensitivity, stability, and accuracy.
Collapse
Affiliation(s)
- Zhenbo Wang
- School of Pharmacy, Ningxia Medical University, Yinchuan, 750004, PR China
| | - Jing Chen
- School of Pharmacy, Ningxia Medical University, Yinchuan, 750004, PR China
| | - Hua Ma
- School of Pharmacy, Ningxia Medical University, Yinchuan, 750004, PR China
| | - Yaru Deng
- School of Pharmacy, Ningxia Medical University, Yinchuan, 750004, PR China
| | - Yafei Li
- School of Pharmacy, Ningxia Medical University, Yinchuan, 750004, PR China
| | - Lijie Geng
- School of Pharmacy, Ningxia Medical University, Yinchuan, 750004, PR China
| | - Yu Huang
- School of Pharmacy, Ningxia Medical University, Yinchuan, 750004, PR China; Key Laboratory of Protection, Development and Utilization of Medicinal Resources in Liupanshan Area Ministry of Education, Ningxia Medical University, Yinchuan, 750004, PR China; Collaborative Innovation Center for Ningxia Characteristic Traditional Chinese Medicine by Ningxia Hui Autonomous Region & Education Ministry of P.R. China, PR China; Ningxia Characteristic Traditional Chinese Medicine Modern Engineering and Technique Research Center, Ningxia Key Laboratory of Drug Development and Generic Drug Research, Key Laboratory of Ningxia Ethnomedicine Modernization, Ministry of Education, Yinchuan, 750004, PR China.
| | - Yanru Fan
- School of Pharmacy, Ningxia Medical University, Yinchuan, 750004, PR China; Key Laboratory of Protection, Development and Utilization of Medicinal Resources in Liupanshan Area Ministry of Education, Ningxia Medical University, Yinchuan, 750004, PR China; Collaborative Innovation Center for Ningxia Characteristic Traditional Chinese Medicine by Ningxia Hui Autonomous Region & Education Ministry of P.R. China, PR China; Ningxia Characteristic Traditional Chinese Medicine Modern Engineering and Technique Research Center, Ningxia Key Laboratory of Drug Development and Generic Drug Research, Key Laboratory of Ningxia Ethnomedicine Modernization, Ministry of Education, Yinchuan, 750004, PR China.
| |
Collapse
|
7
|
Alyamni N, Abot JL, Zestos AG. Perspective-Advances in Voltammetric Methods for the Measurement of Biomolecules. ECS SENSORS PLUS 2024; 3:027001. [PMID: 38645638 PMCID: PMC11024638 DOI: 10.1149/2754-2726/ad3c4f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 04/03/2024] [Accepted: 04/09/2024] [Indexed: 04/23/2024]
Abstract
Voltammetry is a powerful electroanalytical tool that makes fast, real-time measurements of neurotransmitters and other molecules. Electroanalytical methods like cyclic, pulse, and stripping voltammetry are useful for qualitative and quantitative examination. Neurochemical sensing has been enhanced using carbon-based electrodes and waveform modification methods that improve sensitivity and stability of electrode performance. Voltammetry has revolutionized neurochemical monitoring by providing real-time information on neurotransmitter dynamics for neurochemical studies. Selectivity and electrode fouling remain issues for biomolecule detection, but recent advances promise new methods of analysis for other applications to enhance spatiotemporal resolution, sensitivity, selectivity, and other important considerations.
Collapse
Affiliation(s)
- Nadiah Alyamni
- Department of Biomedical Engineering, The Catholic University of America, Washington, DC, 20064, United States of America
- Department of Chemistry, American University, Washington, D.C. 20016, United States of America
| | - Jandro L. Abot
- Department of Mechanical Engineering, The Catholic University of America, Washington, DC, 20064, United States of America
| | - Alexander G. Zestos
- Department of Chemistry, American University, Washington, D.C. 20016, United States of America
| |
Collapse
|
8
|
Luis-Sunga M, Carinelli S, García G, González-Mora JL, Salazar-Carballo PA. Electrochemical Detection of Bisphenol A Based on Gold Nanoparticles/Multi-Walled Carbon Nanotubes: Applications on Glassy Carbon and Screen Printed Electrodes. SENSORS (BASEL, SWITZERLAND) 2024; 24:2570. [PMID: 38676187 PMCID: PMC11054518 DOI: 10.3390/s24082570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 04/12/2024] [Accepted: 04/13/2024] [Indexed: 04/28/2024]
Abstract
Bisphenol A (BPA) has been classified as an endocrine-disrupting substance that may cause adverse effects on human health and the environment. The development of simple and sensitive electrochemical biosensors is crucial for the rapid and effective quantitative determination of BPA. This work presents a study on electrochemical sensors utilizing gold nanoparticle-modified multi-walled carbon nanotubes (CNT/AuNPs). Glassy carbon electrodes (GCEs) and screen-printed electrodes (SPEs) were conveniently modified and used for BPA detection. AuNPs were electrodeposited onto the CNT-modified electrodes using the galvanostatic method. The electrodes were properly modified and characterized by using Raman spectroscopy, cyclic voltammetry (CV), and electrochemical impedance analysis (EIS). The electrochemical response of the sensors was studied using differential pulse voltammetry (DPV) and constant potential amperometry (CPA) for modified GCE and SPE electrodes, respectively, and the main analytical parameters were studied and optimized. Problems encountered with the use of GCEs, such as sensor degradation and high limit of detection (LOD), were overcome by using modified SPEs and a flow injection device for the measurements. Under this approach, an LOD as low as 5 nM (S/N = 3) was achieved and presented a linear range up to 20 μM. Finally, our investigation addressed interference, reproducibility, and reusability aspects, successfully identifying BPA in both spiked and authentic samples, including commercial and tap waters. These findings underscore the practical applicability of our method for accurate BPA detection in real-world scenarios. Notably, the integration of SPEs and a flow injection device facilitated simplified automation, offering an exceptionally efficient and reliable solution for precise BPA detection in water analysis laboratories.
Collapse
Affiliation(s)
- Maximina Luis-Sunga
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, Universidad de la Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain; (M.L.-S.); (J.L.G.-M.); (P.A.S.-C.)
- Departamento de Química, Instituto Universitario de Materiales y Nanotecnología, Universidad de la Laguna, P.O. Box 456, 38200 La Laguna, Spain;
| | - Soledad Carinelli
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, Universidad de la Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain; (M.L.-S.); (J.L.G.-M.); (P.A.S.-C.)
- Departamento de Ciencias Médicas Básicas and Instituto de Tecnologías Biomédicas, Universidad de La Laguna, 38200 La Laguna, Spain
| | - Gonzalo García
- Departamento de Química, Instituto Universitario de Materiales y Nanotecnología, Universidad de la Laguna, P.O. Box 456, 38200 La Laguna, Spain;
| | - José Luis González-Mora
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, Universidad de la Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain; (M.L.-S.); (J.L.G.-M.); (P.A.S.-C.)
- Departamento de Ciencias Médicas Básicas and Instituto de Tecnologías Biomédicas, Universidad de La Laguna, 38200 La Laguna, Spain
- Instituto Universitario de Neurociencia, Universidad de la Laguna, 38071 Santa Cruz de Tenerife, Spain
| | - Pedro A. Salazar-Carballo
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, Universidad de la Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain; (M.L.-S.); (J.L.G.-M.); (P.A.S.-C.)
| |
Collapse
|
9
|
Bounegru AV, Iticescu C, Georgescu LP, Apetrei C. Development of an Innovative Biosensor Based on Graphene/PEDOT/Tyrosinase for the Detection of Phenolic Compounds in River Waters. Int J Mol Sci 2024; 25:4419. [PMID: 38674004 PMCID: PMC11049897 DOI: 10.3390/ijms25084419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 04/02/2024] [Accepted: 04/15/2024] [Indexed: 04/28/2024] Open
Abstract
Phenolic compounds, originating from industrial, agricultural, and urban sources, can leach into flowing waters, adversely affecting aquatic life, biodiversity, and compromising the quality of drinking water, posing potential health hazards to humans. Thus, monitoring and mitigating the presence of phenolic compounds in flowing waters are essential for preserving ecosystem integrity and safeguarding public health. This study explores the development and performance of an innovative sensor based on screen-printed electrode (SPE) modified with graphene (GPH), poly(3,4-ethylenedioxythiophene) (PEDOT), and tyrosinase (Ty), designed for water analysis, focusing on the manufacturing process and the obtained electroanalytical results. The proposed biosensor (SPE/GPH/PEDOT/Ty) was designed to achieve a high level of precision and sensitivity, as well as to allow efficient analytical recoveries. Special attention was given to the manufacturing process and optimization of the modifying elements' composition. This study highlights the potential of the biosensor as an efficient and reliable solution for water analysis. Modification with graphene, the synthesis and electropolymerization deposition of the PEDOT polymer, and tyrosinase immobilization contributed to obtaining a high-performance and robust biosensor, presenting promising perspectives in monitoring the quality of the aquatic environment. Regarding the electroanalytical experimental results, the detection limits (LODs) obtained with this biosensor are extremely low for all phenolic compounds (8.63 × 10-10 M for catechol, 7.72 × 10-10 M for 3-methoxycatechol, and 9.56 × 10-10 M for 4-methylcatechol), emphasizing its ability to accurately measure even subtle variations in the trace compound parameters. The enhanced sensitivity of the biosensor facilitates detection and quantification in river water samples. Analytical recovery is also an essential aspect, and the biosensor presents consistent and reproducible results. This feature significantly improves the reliability and usefulness of the biosensor in practical applications, making it suitable for monitoring industrial or river water.
Collapse
Affiliation(s)
| | | | | | - Constantin Apetrei
- Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, “Dunărea de Jos” University of Galati, 47 Domneasca Street, 800008 Galați, Romania; (A.V.B.); (C.I.)
| |
Collapse
|
10
|
Aydın EB, Aydın M, Sezgintürk MK. Label-Free Electrochemical Immunosensor Based on Conjugated Polymer Film Coated Disposable Electrode for Ultrasensitive Determination of Resistin Potential Obesity Biomarker. ACS APPLIED BIO MATERIALS 2024; 7:1820-1830. [PMID: 38395746 PMCID: PMC10952011 DOI: 10.1021/acsabm.3c01231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 02/09/2024] [Accepted: 02/11/2024] [Indexed: 02/25/2024]
Abstract
A new label-free immunosensor was designed for sensitive detection of resistin obesity biomarker in human biological fluids. To construct a sensing interface, the monomer of double epoxy groups-substituted thiophene (TdiEpx) was synthesized for the fabrication of the biosensing system. A disposable indium tin oxide sheet was first modified by electrochemical polymerization of the TdiEpx monomer, and this robust and novel surface was characterized using different spectroscopic and electrochemical analyses. The double epoxy ends were linked to the amino ends of anti-resistin, and they served as binding points for the covalent binding of biomolecules. The double epoxy ends present in each TdiEpx monomer ensured an extensive surface area, which improved the quantity of attached anti-resistin. The determination of resistin antigen was based on the specific coupling of resistin with anti-resistin, and this interaction hindered the electron transfer reaction. The immunosensor introduced a wide linear range of 0.0125-15 pg/mL, a low detection limit of 4.17 fg/mL, and an excellent sensitivity of 1.38 kohm pg mL-1 cm2. In this study, a sandwich enzyme-linked immunosorbent assay spectrophotometric method was utilized as a reference technique for the quantitative analysis of resistin in human serum and saliva samples. Both measurements in clinical samples displayed correlations and high-correlation coefficients. In addition, this immunosensor had good storage stability, acceptable repeatability and reproducibility, high specificity, and good accuracy. The proposed immunosensor provided a simple and versatile impedimetric immunosensing platform and a promisingly sensitive way for clinical applications.
Collapse
Affiliation(s)
- Elif Burcu Aydın
- Scientific
and Technological Research Center, Tekirdaǧ
Namık Kemal University, Tekirdaǧ, Turkey 59030
| | - Muhammet Aydın
- Scientific
and Technological Research Center, Tekirdaǧ
Namık Kemal University, Tekirdaǧ, Turkey 59030
| | - Mustafa Kemal Sezgintürk
- Bioengineering
Department, Faculty of Engineering, Çanakkale
Onsekiz Mart University, Çanakkale, Turkey 17100
| |
Collapse
|
11
|
Zhang M, Wang Y, Jiang J, Jiang Y, Song D. The Role of Catecholamines in the Pathogenesis of Diseases and the Modified Electrodes for Electrochemical Detection of Catecholamines: A Review. Crit Rev Anal Chem 2024:1-22. [PMID: 38462811 DOI: 10.1080/10408347.2024.2324460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
Catecholamines (CAs), which include adrenaline, noradrenaline, and dopamine, are neurotransmitters and hormones that critically regulate the cardiovascular system, metabolism, and stress response in the human body. The abnormal levels of these molecules can lead to the development of various diseases, including pheochromocytoma and paragangliomas, Alzheimer's disease, and Takotsubo cardiomyopathy. Due to their low cost, high sensitivity, flexible detection strategies, ease of integration, and miniaturization, electrochemical techniques have been extensively employed in the detection of CAs, surpassing traditional analytical methods. Electrochemical detection of CAs in real samples is challenging due to the tendency of poisoning electrode. Chemically modified electrodes have been widely used to solve the problems of poor sensitivity and selectivity faced by bare electrodes. There are a few articles that provide an overview of electrochemical detection and efficient enrichment of CAs, but there is a dearth of updates on the role of CAs in the pathogenesis of diseases. Additionally, there is still a lack of systematic synthesis with a focus on modified electrodes for electrochemical detection. Thus, this review provides a summary of the recent clinical pathogenesis of CAs and the modified electrodes for electrochemical detection of CAs published between 2017 and 2022. Moreover, challenges and future perspectives are also highlighted. This work is expected to provide useful guidance to researchers entering this interdisciplinary field, promoting further development of CAs pathogenesis, and developing more novel chemically modified electrodes for the detection of CAs.
Collapse
Affiliation(s)
- Meng Zhang
- School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Weihai, Shandong, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China
| | - Yimeng Wang
- Elite Engineer School, Harbin Institute of Technology, Harbin, Heilongjiang, China
| | - Jie Jiang
- School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Weihai, Shandong, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang, China
| | - Yanxiao Jiang
- School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Weihai, Shandong, China
| | - Daqian Song
- College of Chemistry, Jilin University, Changchun, Jilin, China
| |
Collapse
|
12
|
Lee J, Park S, Lee J, Kim N, Kim MK. Recent advances of additively manufactured noninvasive kinematic biosensors. Front Bioeng Biotechnol 2023; 11:1303004. [PMID: 38047290 PMCID: PMC10690938 DOI: 10.3389/fbioe.2023.1303004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 10/31/2023] [Indexed: 12/05/2023] Open
Abstract
The necessity of reliable measurement data assessment in the realm of human life has experienced exponential growth due to its extensive utilization in health monitoring, rehabilitation, surgery, and long-term treatment. As a result, the significance of kinematic biosensors has substantially increased across various domains, including wearable devices, human-machine interaction, and bioengineering. Traditionally, the fabrication of skin-mounted biosensors involved complex and costly processes such as lithography and deposition, which required extensive preparation. However, the advent of additive manufacturing has revolutionized biosensor production by facilitating customized manufacturing, expedited processes, and streamlined fabrication. AM technology enables the development of highly sensitive biosensors capable of measuring a wide range of kinematic signals while maintaining a low-cost aspect. This paper provides a comprehensive overview of state-of-the-art noninvasive kinematic biosensors created using diverse AM technologies. The detailed development process and the specifics of different types of kinematic biosensors are also discussed. Unlike previous review articles that primarily focused on the applications of additively manufactured sensors based on their sensing data, this article adopts a unique approach by categorizing and describing their applications according to their sensing frequencies. Although AM technology has opened new possibilities for biosensor fabrication, the field still faces several challenges that need to be addressed. Consequently, this paper also outlines these challenges and provides an overview of future applications in the field. This review article offers researchers in academia and industry a comprehensive overview of the innovative opportunities presented by kinematic biosensors fabricated through additive manufacturing technologies.
Collapse
Affiliation(s)
- Jeonghoon Lee
- Department of Mechanical Convergence Engineering, Hanyang University, Seoul, Republic of Korea
| | - Sangmin Park
- Department of Mechanical Engineering, Gachon University, Seongnam, Republic of Korea
| | - Jaehoon Lee
- Department of Mechanical Engineering, Gachon University, Seongnam, Republic of Korea
| | - Namjung Kim
- Department of Mechanical Engineering, Gachon University, Seongnam, Republic of Korea
| | - Min Ku Kim
- School of Mechanical Engineering, Hanyang University, Seoul, Republic of Korea
| |
Collapse
|
13
|
Feng Z, Lim HN, Ibrahim I, Gowthaman NSK. A review of zeolitic imidazolate frameworks (ZIFs) as electrochemical sensors for important small biomolecules in human body fluids. J Mater Chem B 2023; 11:9099-9127. [PMID: 37650588 DOI: 10.1039/d3tb01221b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
Small biomolecules play a critical role in the fundamental processes that sustain life and are essential for the proper functioning of the human body. The detection of small biomolecules has garnered significant interest in various fields, including disease diagnosis and medicine. Electrochemical techniques are commonly employed in the detection of critical biomolecules through the principle of redox reactions. It is also a very convenient, cheap, simple, fast, and accurate measurement method in analytical chemistry. Zeolitic imidazolate frameworks (ZIFs) are a unique type of metal-organic framework (MOF) composed of porous crystals with extended three-dimensional structures. These frameworks are made up of metal ions and imidazolate linkers, which form a highly porous and stable structure. In addition to their many advantages in other applications, ZIFs have emerged as promising candidates for electrochemical sensors. Their large surface area, pore diameter, and stability make them ideal for use in sensing applications, particularly in the detection of small molecules and ions. This review summarizes the critical role of small biomolecules in the human body, the standard features of electrochemical analysis, and the utilization of various types of ZIF materials (including carbon composites, metal-based composites, ZIF polymer materials, and ZIF-derived materials) for the detection of important small biomolecules in human body fluids. Lastly, we provide an overview of the current status, challenges, and future outlook for research on ZIF materials.
Collapse
Affiliation(s)
- Zhou Feng
- Department of Chemistry, Faculty of Science, University Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia.
| | - H N Lim
- Department of Chemistry, Faculty of Science, University Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia.
- Foundry of Reticular Materials for Sustainability (FORMS) Laboratory, Institute of Advanced Technology, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia
| | - I Ibrahim
- Foundry of Reticular Materials for Sustainability (FORMS) Laboratory, Institute of Advanced Technology, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia
- Functional Nanotechnology Devices Laboratory (FNDL), Institute of Nanoscience and Nanotechnology, Universiti Putra Malaysia, 43400 Serdang, Selangor, Malaysia
| | - N S K Gowthaman
- School of Engineering, Monash University Malaysia, Jalan Lagoon Selatan, 47500, Bandar Sunway, Selangor, Malaysia
| |
Collapse
|
14
|
Fredj Z, Wang P, Ullah F, Sawan M. A nanoplatform-based aptasensor to electrochemically detect epinephrine produced by living cells. Mikrochim Acta 2023; 190:343. [PMID: 37540351 DOI: 10.1007/s00604-023-05902-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Accepted: 07/04/2023] [Indexed: 08/05/2023]
Abstract
A novel aptasensor has been designed for quantitative monitoring of epinephrine (EP) based on cerium metal-organic framework (CeMOF) loaded gold nanoparticles (AuNPs). The aptamer, specific to EP, is immobilized on a flexible screen-printed electrode modified with AuNPs@CeMOF, enabling highly selective binding to the target biomolecule. Under optimized operational conditions, the peak currents using voltammetric detection measured at voltage of 83 mV (vs. Ag/AgCl) for epinephrine exhibit a linear increase within concentration in the range 1 pM-10 nM. Following this detection strategy, a boasted limit of detection of 0.3 pM was achieved, surpassing the sensitivity of most reported methods. The developed biosensor showcased exceptional performance in detection of EP in spiked serum sample, with remarkable recovery range of 95.8-113% and precision reflected by low relative standard deviation (RSD) ranging from 2.23 to 6.19%. These results indicate the potential utility of this biosensor as a valuable clinical diagnostic tool. Furthermore, in vitro experiments were carried out using the presented biosensor to monitor the release of epinephrine from PC12 cells upon extracellular stimulation with K+ ions.
Collapse
Affiliation(s)
- Zina Fredj
- CenBRAIN Neurotech, School of Engineering, Westlake University, Hangzhou, 310030, China
| | - Pengbo Wang
- CenBRAIN Neurotech, School of Engineering, Westlake University, Hangzhou, 310030, China
| | - Fateh Ullah
- CenBRAIN Neurotech, School of Engineering, Westlake University, Hangzhou, 310030, China
| | - Mohamad Sawan
- CenBRAIN Neurotech, School of Engineering, Westlake University, Hangzhou, 310030, China.
| |
Collapse
|
15
|
Choi HK, Yoon J. Enzymatic Electrochemical/Fluorescent Nanobiosensor for Detection of Small Chemicals. BIOSENSORS 2023; 13:bios13040492. [PMID: 37185567 PMCID: PMC10136675 DOI: 10.3390/bios13040492] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 04/13/2023] [Accepted: 04/18/2023] [Indexed: 05/17/2023]
Abstract
The detection of small molecules has attracted enormous interest in various fields, including the chemical, biological, and healthcare fields. In order to achieve such detection with high accuracy, up to now, various types of biosensors have been developed. Among those biosensors, enzymatic biosensors have shown excellent sensing performances via their highly specific enzymatic reactions with small chemical molecules. As techniques used to implement the sensing function of such enzymatic biosensors, electrochemical and fluorescence techniques have been mostly used for the detection of small molecules because of their advantages. In addition, through the incorporation of nanotechnologies, the detection property of each technique-based enzymatic nanobiosensors can be improved to measure harmful or important small molecules accurately. This review provides interdisciplinary information related to developing enzymatic nanobiosensors for small molecule detection, such as widely used enzymes, target small molecules, and electrochemical/fluorescence techniques. We expect that this review will provide a broad perspective and well-organized roadmap to develop novel electrochemical and fluorescent enzymatic nanobiosensors.
Collapse
Affiliation(s)
- Hye Kyu Choi
- Department of Chemistry and Chemical Biology, Rutgers, The State University of New Jersey, Piscataway, NJ 08854, USA
| | - Jinho Yoon
- Department of Biomedical-Chemical Engineering, The Catholic University of Korea, 43 Jibong-ro, Bucheon-si 14662, Gyeonggi-do, Republic of Korea
| |
Collapse
|
16
|
Bounegru AV, Apetrei C. Tyrosinase Immobilization Strategies for the Development of Electrochemical Biosensors-A Review. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:760. [PMID: 36839128 PMCID: PMC9962745 DOI: 10.3390/nano13040760] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Revised: 02/11/2023] [Accepted: 02/15/2023] [Indexed: 06/18/2023]
Abstract
The development of enzyme biosensors has successfully overcome various challenges such as enzyme instability, loss of enzyme activity or long response time. In the electroanalytical field, tyrosinase is used to develop biosensors that exploit its ability to catalyze the oxidation of numerous types of phenolic compounds with antioxidant and neurotransmitter roles. This review critically examines the main tyrosinase immobilization techniques for the development of sensitive electrochemical biosensors. Immobilization strategies are mainly classified according to the degree of reversibility/irreversibility of enzyme binding to the support material. Each tyrosinase immobilization method has advantages and limitations, and its selection depends mainly on the type of support electrode, electrode-modifying nanomaterials, cross-linking agent or surfactants used. Tyrosinase immobilization by cross-linking is characterized by very frequent use with outstanding performance of the developed biosensors. Additionally, research in recent years has focused on new immobilization strategies involving cross-linking, such as cross-linked enzyme aggregates (CLEAs) and magnetic cross-linked enzyme aggregates (mCLEAs). Therefore, it can be considered that cross-linking immobilization is the most feasible and economical approach, also providing the possibility of selecting the reagents used and the order of the immobilization steps, which favor the enhancement of biosensor performance characteristics.
Collapse
|
17
|
Kulkarni MB, Ayachit NH, Aminabhavi TM. Recent Advancements in Nanobiosensors: Current Trends, Challenges, Applications, and Future Scope. BIOSENSORS 2022; 12:892. [PMID: 36291028 PMCID: PMC9599941 DOI: 10.3390/bios12100892] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 10/14/2022] [Accepted: 10/17/2022] [Indexed: 05/30/2023]
Abstract
In recent years, there has been immense advancement in the development of nanobiosensors as these are a fundamental need of the hour that act as a potential candidate integrated with point-of-care-testing for several applications, such as healthcare, the environment, energy harvesting, electronics, and the food industry. Nanomaterials have an important part in efficiently sensing bioreceptors such as cells, enzymes, and antibodies to develop biosensors with high selectivity, peculiarity, and sensibility. It is virtually impossible in science and technology to perform any application without nanomaterials. Nanomaterials are distinguished from fine particles used for numerous applications as a result of being unique in properties such as electrical, thermal, chemical, optical, mechanical, and physical. The combination of nanostructured materials and biosensors is generally known as nanobiosensor technology. These miniaturized nanobiosensors are revolutionizing the healthcare domain for sensing, monitoring, and diagnosing pathogens, viruses, and bacteria. However, the conventional approach is time-consuming, expensive, laborious, and requires sophisticated instruments with skilled operators. Further, automating and integrating is quite a challenging process. Thus, there is a considerable demand for the development of nanobiosensors that can be used along with the POCT module for testing real samples. Additionally, with the advent of nano/biotechnology and the impact on designing portable ultrasensitive devices, it can be stated that it is probably one of the most capable ways of overcoming the aforementioned problems concerning the cumulative requirement for the development of a rapid, economical, and highly sensible device for analyzing applications within biomedical diagnostics, energy harvesting, the environment, food and water, agriculture, and the pharmaceutical industry.
Collapse
Affiliation(s)
- Madhusudan B. Kulkarni
- Department of Research & Development, Renalyx Health Systems (P) Limited, Bengaluru 560004, Karnataka, India
| | - Narasimha H. Ayachit
- Department of Physics, Visvesvaraya Technological University (VTU), Belagavi 590018, Karnataka, India
| | - Tejraj M. Aminabhavi
- School of Advanced Sciences, KLE Technological University, Hubballi 580031, Karnataka, India
| |
Collapse
|