1
|
Luevitoonvechakij N, Buranapim N, Suriyasathaporn W, Bansiddhi P, Warrit K, Punyapornwithaya V, Suriyasathaporn W. Cadaveric Study on Comparison of Neck Extension Angles for Endotracheal Intubation in Rabbits Using a Rigid and Flexible Endoscope. Animals (Basel) 2024; 14:1270. [PMID: 38731275 PMCID: PMC11083616 DOI: 10.3390/ani14091270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 04/19/2024] [Accepted: 04/22/2024] [Indexed: 05/13/2024] Open
Abstract
Endotracheal intubation in rabbits is always challenging due to the unique anatomical conformation. To improve endotracheal intubation success, this study determined the relationship between head placement angles guided by endoscope-assisted visualization techniques and the endotracheal intubation success rate. Thirty-two rabbit cadavers were used in the study. Six veterinary practitioners who had no experience with rabbit endotracheal intubation were randomly assigned to intubate rabbit cadavers using the guidance of either a rigid endoscope (RE) or flexible endoscope (FE), with the head placement angles with an ascending neck at 90, 100, 110, 120 and 130 degrees. The endotracheal intubation completed in 90 s was determined to be a success. The success rates using RE and FE were 97.2% and 95.9%, respectively. The means and standard error of means (SEM) of endotracheal intubation times guided by RE and FE were 53.7 ± 4.68 and 55.2 ± 4.24 s, respectively. Results from survival time analysis show that the five veterinarians successfully intubated the rabbit within 90 s, regardless of the different types of endoscopes. Angle was the only significant factor that affected the endotracheal intubation success. The head placement angle at 110 and 120 degrees had the highest success rate of endotracheal intubation compared to 90 degrees (p ≤ 0.05). In conclusion, for inexperienced veterinarians, the success of endotracheal intubation in rabbits, guided by endoscope-assisted visualized techniques regardless of rigid endoscope or flexible endoscope guidance, is improved when the head extension is 110 and 120 degrees.
Collapse
Affiliation(s)
- Nicharee Luevitoonvechakij
- Graduate Program in Veterinary Science, Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand;
- Center of Elephant and Wildlife Health, Chiang Mai University Animal Hospital, Chiang Mai University, Chiang Mai 50100, Thailand;
| | - Nithidol Buranapim
- Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand; (N.B.); (W.S.); (K.W.); (V.P.)
| | - Witaya Suriyasathaporn
- Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand; (N.B.); (W.S.); (K.W.); (V.P.)
- Research Center of Producing and Development of Products and Innovations for Animal Health and Production, Chiang Mai University, Chiang Mai 50100, Thailand
- Asian Satellite Campuses Institute, Nagoya University, Nagoya 464-8603, Japan
| | - Pakkanut Bansiddhi
- Center of Elephant and Wildlife Health, Chiang Mai University Animal Hospital, Chiang Mai University, Chiang Mai 50100, Thailand;
- Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand; (N.B.); (W.S.); (K.W.); (V.P.)
| | - Kanawee Warrit
- Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand; (N.B.); (W.S.); (K.W.); (V.P.)
| | - Veerasak Punyapornwithaya
- Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand; (N.B.); (W.S.); (K.W.); (V.P.)
| | - Wanna Suriyasathaporn
- Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand; (N.B.); (W.S.); (K.W.); (V.P.)
- Research Center of Producing and Development of Products and Innovations for Animal Health and Production, Chiang Mai University, Chiang Mai 50100, Thailand
| |
Collapse
|
2
|
Nejamkin P, Clausse M, Landivar F, Lorenzutti MA, Cavilla V, Viviani P, Alvarez LI, Del Sole MJ. Development and evaluation of an anatomically designed and 3D printed device to enhance orotracheal intubation success in rabbits by inexperienced veterinarians. Vet Anaesth Analg 2023; 50:273-279. [PMID: 36967327 DOI: 10.1016/j.vaa.2023.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 03/01/2023] [Accepted: 03/01/2023] [Indexed: 03/12/2023]
Abstract
OBJECTIVE To assess whether the use of a three-dimensional (3D) printed device enhances the success rate of orotracheal intubation in rabbits. STUDY DESIGN Prospective, crossover randomized controlled trial. ANIMALS A total of six mixed-breed rabbits. METHODS A device to guide the endotracheal tube was designed based on computed tomography images and then manufactured using 3D printing. Rabbits were randomly assigned for intubation by two inexperienced veterinarians using the blind (BLI), borescope- (BOR) or device- (DEV) guided techniques. Success rate, number of attempts, time to success, injury scores and propofol dose were recorded and compared. Significance was considered when p < 0.05. RESULTS Success rate was higher in DEV (58.3%) than in BLI (8.3%) (p < 0.023), but not different from that in BOR (41.6%). Total time until successful intubation was lower in DEV (45 ± 23 seconds) and BOR (85 ± 62 seconds) than in BLI (290 seconds; p < 0.006). Time for the successful attempt was lower for DEV (35 ± 10 seconds) and BOR (74 ± 43 seconds) than in BLI (290 seconds; p < 0.0001). The propofol dose required was lower for DEV (2.3 ± 1.2 mg kg-1) than for BLI (3.4 ± 1.6 mg kg-1) (p < 0.031), but not different from BOR (2.4 ± 0.9 mg kg-1). Number of attempts and oxygen desaturation events were not different among techniques (p < 0.051 and p < 0.326, respectively). Injury scores [median (range)] before and after attempts were different in BLI [0 versus 1 (0-3), p < 0.005] and BOR [0 (0-1) versus 1 (0-3), p < 0.002] but not in DEV [0 (0-2) versus 0 (0-3), p < 0.109]. CONCLUSIONS AND CLINICAL RELEVANCE The device facilitated orotracheal intubation with a time similar to the borescope-guided technique but faster than the traditional blind technique.
Collapse
Affiliation(s)
- Pablo Nejamkin
- Universidad Nacional del Centro de la Provincia de Buenos Aires, Facultad de Ciencias Veterinarias, MEVET, Tandil, BA, Argentina; CIVETAN, UNCPBA-CONICET, Tandil, BA, Argentina.
| | - María Clausse
- Universidad Nacional del Centro de la Provincia de Buenos Aires, Facultad de Ciencias Veterinarias, MEVET, Tandil, BA, Argentina; CIVETAN, UNCPBA-CONICET, Tandil, BA, Argentina
| | - Florencia Landivar
- Universidad Nacional del Centro de la Provincia de Buenos Aires, Facultad de Ciencias Veterinarias, MEVET, Tandil, BA, Argentina
| | - Matías A Lorenzutti
- Facultad de Ciencias Agropecuarias, IRNASUS CONICET - Universidad Católica de Córdoba, CB, Argentina
| | - Verónica Cavilla
- Universidad Nacional del Centro de la Provincia de Buenos Aires, Facultad de Ciencias Veterinarias, MEVET, Tandil, BA, Argentina
| | - Paula Viviani
- Universidad Nacional del Centro de la Provincia de Buenos Aires, Facultad de Ciencias Veterinarias, MEVET, Tandil, BA, Argentina; Department of Large Animal Clinical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK, Canada
| | - Luis I Alvarez
- CIVETAN, UNCPBA-CONICET, Tandil, BA, Argentina; Universidad Nacional del Centro de la Provincia de Buenos Aires, Facultad de Ciencias Veterinarias, FISFARVET, Tandil, BA, Argentina
| | - María J Del Sole
- Universidad Nacional del Centro de la Provincia de Buenos Aires, Facultad de Ciencias Veterinarias, MEVET, Tandil, BA, Argentina
| |
Collapse
|
3
|
Comparison of blind and endoscopic-guided orotracheal intubation on laryngeal and tracheal damage in domestic rabbits (Oryctolagus cuniculus). Vet Anaesth Analg 2022; 49:398-406. [DOI: 10.1016/j.vaa.2022.04.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 04/09/2022] [Accepted: 04/10/2022] [Indexed: 11/24/2022]
|
4
|
Abstract
With the increasing frequency of rabbits as veterinary patients, the expectation for high-quality, intensive veterinary care, and resultantly an understanding of anesthesia has been increasing. Sedation and general anesthesia are commonly required for many routine and emergency procedures in rabbits, and this results in the need for a strong awareness of anesthetic principles, knowledge of limitations of anesthesia, and maintenance of high standards of anesthesia.
Collapse
|
5
|
Reabel SN, Queiroz-Williams P, Cremer J, Hampton CE, Liu CC, da Cunha A, Nevarez JG. Assessment of intramuscular administration of three doses of alfaxalone combined with hydromorphone and dexmedetomidine for endoscopic-guided orotracheal intubation in domestic rabbits (Oryctolagus cuniculus). J Am Vet Med Assoc 2021; 259:1148-1153. [PMID: 34727075 DOI: 10.2460/javma.20.07.0402] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To determine the dose of alfaxalone for IM administration combined with dexmedetomidine and hydromorphone that would allow endoscopic-guided orotracheal intubation in rabbits without causing a decrease in respiratory rate or apnea. ANIMALS 15 sexually intact (9 females and 6 males) healthy Miniature Lop rabbits weighing a mean ± SD of 2.3 ± 0.3 kg and ranging in age from 4 to 9 months. PROCEDURES In a randomized, controlled clinical trial, rabbits received 0.1 mg of hydro-morphone/kg and 0.005 mg of dexmedetomidine/kg, plus alfaxalone at either 2 mg/kg (5 rabbits), 5 mg/kg (5 rabbits), or 7 mg/kg (5 rabbits). Drugs were mixed in a single syringe and administered IM. Semiquantitative rating scales were used to evaluate quality of anesthesia and intubation. Orotracheal intubation was attempted with endoscopy and confirmed by capnography. RESULTS The number of successful intubations was 0, 3, and 4 in rabbits receiving 2, 5, and 7 mg of alfaxalone/kg, respectively. Median (range) anesthesia quality scores (scale, 0 to 12; 12 = deepest anesthesia) were 3 (2 to 5), 6 (5 to 6), and 6 (4 to 9) for rabbits receiving 2, 5, and 7 mg of alfaxalone/kg, respectively. The median (range) intubation quality scores (scale, 0 to 3 [ie, intubation not possible to easiest intubation]) were 0 (0 to 0), 2 (0 to 3), and 2 (0 to 3) for rabbits receiving 2, 5, and 7 mg of alfaxalone/kg, respectively. None of the rabbits experienced a decrease in respiratory rate or apnea. CONCLUSIONS AND CLINICAL RELEVANCE Increasing doses of alfaxalone combined with hydromorphone and dexmedetomidine increased the success rate of endoscopic-guided orotracheal intubation. Increasing the dose of alfaxalone had no effect on respiratory rate.
Collapse
|
6
|
Fusco A, Douglas H, Barba A, Hopster K, Stefanovski D, Sinder B, Cahill PJ, Snyder B, Schaer TP. V-Gel ® Guided Endotracheal Intubation in Rabbits. Front Vet Sci 2021; 8:684624. [PMID: 34447802 PMCID: PMC8383107 DOI: 10.3389/fvets.2021.684624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Accepted: 07/09/2021] [Indexed: 11/13/2022] Open
Abstract
Background: General anesthesia in rabbits is associated with higher morbidity and mortality relative to other mammalian species commonly anesthetized. Unique challenges related to endotracheal intubation (ETI) in rabbits contribute to this risk. Objective: To improve the safety of ETI in rabbits, we developed two new ETI methods using a supraglottic airway device (v-gel®) to facilitate ETI and compared them to traditional "blind" technique. We hypothesized that relative to blind ETI, v-gel® guided ETI provides more successful placement of the endotracheal tube (ETT) in a shorter time. Outcomes included number of intubation attempts, time for achievement of ETI, endoscopic findings, and serial arterial blood gas (ABG) analysis. Study Design: Prospective, randomized, and crossover study. Methods: Ten female, New Zealand White rabbits aged 1-2 years old, weighing 4.3 ± 0.4 kg, were anesthetized four times. Each time, ETI was performed with one of the following techniques: Method 1: v-gel® guided, polypropylene catheter facilitated, intubation using a cuffed ETT; Method 2: v-gel® guided intubation using an uncuffed ETT directly inserted through the device airway channel; Method 3 and 4: Blind intubation with uncuffed or cuffed ETT. Upper airway endoscopy was performed before intubation attempts and after extubation. Serial ABG analysis was performed during the peri-intubation process. Results: V-gel® guided techniques allowed successful ETI on the initial attempt for 9/10 subjects using Method 1 and 10/10 using Method 2. Relative to the v-gel® guided techniques, the blind techniques required more intubation attempts. A median of 2 attempts (range 1-4, p < 0.007) were required for the uncuffed ETT, and a median of 4 (range 1-4, p < 0.001) attempts were performed for the cuffed ETT. The time to perform successful ETI was positively correlated with the number of attempts (ρ = 0.82), while successful ETI was negatively correlated with number of attempts (ρ = -0.82). Endoscopic findings showed mild to moderate laryngeal trauma. In the absence of oxygen supplementation, ABG analysis demonstrated low PaO2, while PaCO2 remained consistent. Conclusions: Facilitated ETI using the v-gel® guided techniques allows for the rapid establishment of a secure airway to provide ventilatory support for rabbits undergoing general anesthesia.
Collapse
Affiliation(s)
- Alessandra Fusco
- Department of Clinical Studies New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA, United States
| | - Hope Douglas
- Department of Clinical Studies New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA, United States
| | - Adriana Barba
- Department of Clinical Studies New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA, United States
| | - Klaus Hopster
- Department of Clinical Studies New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA, United States
| | - Darko Stefanovski
- Department of Clinical Studies New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA, United States
| | - Benjamin Sinder
- Division of Orthopaedics, Children's Hospital of Philadelphia, Philadelphia, PA, United States
| | - Patrick J Cahill
- Division of Orthopaedics, Children's Hospital of Philadelphia, Philadelphia, PA, United States
| | - Brian Snyder
- Division of Orthopaedics, Children's Hospital of Philadelphia, Philadelphia, PA, United States.,Department of Orthopaedic Surgery, Children's Hospital, Harvard Medical School, Boston, MA, United States
| | - Thomas P Schaer
- Department of Clinical Studies New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA, United States
| |
Collapse
|
7
|
Huckins GL, Doss GA, Ferreira TH. Evaluation of supraglottic airway device use during inhalation anesthesia in healthy African pygmy hedgehogs (Atelerix albiventris). Vet Anaesth Analg 2021; 48:517-523. [PMID: 33903071 DOI: 10.1016/j.vaa.2021.03.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 03/03/2021] [Accepted: 03/04/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To evaluate a supraglottic airway device (SGAD) designed for rabbits in African pygmy hedgehogs (Atelerix albiventris) during inhalation anesthesia. STUDY DESIGN Prospective, randomized, blinded experimental study. ANIMALS A total of 12 adult African pygmy hedgehogs (seven male, five female). METHODS Hedgehogs were placed in a chamber and anesthesia was induced using isoflurane in oxygen. Oropharyngeal endoscopy was performed and video recorded. The SGAD (v-gel R1) was inserted and connected to a Mapleson D circuit. Capnography, pulse oximetry and physiologic variables were measured during anesthesia, and lung inflation was tested at 10 and 20 cmH2O. With the SGAD temporarily disconnected, anesthetized hedgehogs were randomly positioned into right and left lateral, dorsal and sternal recumbency to evaluate the effect of a change in body position on SGAD placement. Oropharyngeal endoscopy was repeated at the end of anesthesia, and recovery time was recorded. Pre- and post-SGAD placement endoscopy videos were retrospectively reviewed and scored for gross trauma. RESULTS The median [interquartile range (IQR)] time to successful SGAD placement was 38 (16-68) seconds. The time to SGAD placement decreased as the study progressed. SGAD required repositioning in six hedgehogs, median 2.5 (IQR, 1-3.5) adjustments each, to successfully perform lung inflation or maintain capnography readings. Lung inflation at 10 cmH2O was successfully performed without leakage in nine animals, and in the other three animals after adjusting the SGAD at 1-2 time points. Inflation at 20 cmH2O was rarely achieved without an air leak. Changes in heart and respiratory rates during anesthesia were not clinically relevant. Median endoscopic scores were 0 (no lesions) for both pre-and postplacement. CONCLUSIONS AND CLINICAL RELEVANCE The SGAD was relatively quickly and easily placed, permitted lung inflation and caused no significant oropharyngeal damage. The SGAD is a practical option for airway management in African pygmy hedgehogs.
Collapse
Affiliation(s)
- Gail L Huckins
- Department of Surgical Sciences, University of Wisconsin-Madison, School of Veterinary Medicine, Madison, WI, USA
| | - Grayson A Doss
- Department of Surgical Sciences, University of Wisconsin-Madison, School of Veterinary Medicine, Madison, WI, USA.
| | - Tatiana H Ferreira
- Department of Surgical Sciences, University of Wisconsin-Madison, School of Veterinary Medicine, Madison, WI, USA
| |
Collapse
|
8
|
Comparison of blind intubation and a smartphone-based endoscope-assisted intubation in rabbits. Vet Anaesth Analg 2020; 47:826-834. [PMID: 32981837 DOI: 10.1016/j.vaa.2020.07.037] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 07/23/2020] [Accepted: 07/28/2020] [Indexed: 12/12/2022]
Abstract
OBJECTIVE To compare between blind and smartphone-based endoscope-assisted techniques for endotracheal intubation in rabbits. STUDY DESIGN Prospective clinical study. ANIMALS A total of 34 rabbits. METHODS Rabbits were assigned to four groups: intubation by a veterinary anesthesiologist (VA) or an exotic pet medicine specialist (EPS) using blind or endoscope-assisted techniques. Propofol dose, number of attempts until successful intubation, total time for intubation, duration of the successful attempt and occurrence of lingual cyanosis/laryngeal lesions were recorded. Data were analyzed by t test, Wilcoxon-Mann-Whitney U test or chi-square test. Pearson correlation for body weight was performed. RESULTS The success rate of blind intubation was 88.9% and 77.8% for VA and EPS, respectively. Propofol dose, total and median number of attempts, total time for intubation and duration of the successful attempt were 3.1 (0-6.2) mg kg-1, 19, 2 (1-5), 79 ± 65 and 30 ± 20 seconds for VA and 1.5 (0-4.5) mg kg-1, 24, 3 (1-5), 136 ± 92 and 38 ± 16 seconds for EPS. The success rate of endoscope-assisted intubation was 87.5% for both operators. Propofol dose, total and median number of attempts, total time for intubation and duration of the successful attempt were 2.5 (1.3-7.4) mg kg-1, 22, 3 (1-5), 170 (65-368) and 46 (22-150) seconds for VA and 3.2 (0-6) mg kg-1, 11, 1 (1-4), 56 (27-432) and 55 (26-79) seconds for EPS. VA performed blind intubation more quickly, propofol dose was lower and cyanosis was less frequent than in the endoscope-assisted group. CONCLUSIONS AND CLINICAL RELEVANCE Both techniques were reliable for rabbit endotracheal intubation. Best results were achieved when the operator was experienced in the technique. The smartphone-based endoscope is a useful aid for rabbit intubation.
Collapse
|
9
|
Freitag FAV, Muehlbauer E, Martini R, Froes TR, Duque JCM. Smartphone otoscope: an alternative technique for intubation in rabbits. Vet Anaesth Analg 2019; 47:281-284. [PMID: 31973915 DOI: 10.1016/j.vaa.2019.11.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 10/29/2019] [Accepted: 11/19/2019] [Indexed: 01/20/2023]
Affiliation(s)
- Flavio A V Freitag
- Veterinary Sciences Graduate Program, Department of Veterinary Medicine, Federal University of Paraná, Curitiba, PR, Brazil
| | - Eloisa Muehlbauer
- Veterinary Sciences Graduate Program, Department of Veterinary Medicine, Federal University of Paraná, Curitiba, PR, Brazil
| | - Rafaella Martini
- Veterinary Sciences Graduate Program, Department of Veterinary Medicine, Federal University of Paraná, Curitiba, PR, Brazil
| | - Tilde R Froes
- Veterinary Sciences Graduate Program, Department of Veterinary Medicine, Federal University of Paraná, Curitiba, PR, Brazil
| | - Juan C M Duque
- Veterinary Sciences Graduate Program, Department of Veterinary Medicine, Federal University of Paraná, Curitiba, PR, Brazil.
| |
Collapse
|
10
|
Ferris RL, Quesenberry KE, Weisse CW. Outcome of intraluminal tracheal stent placement for tracheal stenosis in a rabbit (Oryctolagus cuniculus). J Exot Pet Med 2019. [DOI: 10.1053/j.jepm.2019.04.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
11
|
Abstract
Medical devices are defined as implantable if they are intended to remain in the body after the procedure. In veterinary medicine, use of such devices is marginal but may find some indications. Use in exotic pet medicine is even more challenging due to size restriction and the limited data available. This review focuses on the esophageal and tracheal stent in the case of stricture, ureteral stent and subcutaneous ureteral bypass in the case of ureteral obstruction, permanent urinary diversion in the case of bladder atony, and pacemaker in the case of severe arrythmias. Comparative aspects are developed.
Collapse
Affiliation(s)
- Minh Huynh
- Centre Hospitalier Vétérinaire Frégis, 43 Avenue Aristide Briand, Arcueil 94110, France.
| |
Collapse
|
12
|
Affiliation(s)
- Adrianna Skarbek
- Anderson Moores Veterinary Specialists, The Granary, Bunstead Barns, Poles Lane, Hursley, Winchaster, Hampshire, SO21 2LL
| | - Karla Borland
- Anderson Moores Veterinary Specialists, The Granary, Bunstead Barns, Poles Lane, Hursley, Winchaster, Hampshire, SO21 2LL
| |
Collapse
|