1
|
Wu HH, Zhang YQ, Yu CD, Yang L, Tao C, Shu W, Li T, Huang G, Hou D, Chen FF, Liu JT, Li SL, Zong XN. Association of height, foot length, and pubertal development in children aged 3-18: a cross-sectional survey in China. Front Public Health 2024; 12:1322333. [PMID: 38410665 PMCID: PMC10894912 DOI: 10.3389/fpubh.2024.1322333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 01/24/2024] [Indexed: 02/28/2024] Open
Abstract
Objective This study aimed to analyze the growth patterns of height and foot length (FL) among Chinese children aged 3-18 and examine their associations with puberty development. Methods A cross-sectional survey was conducted in September 2022 in Beijing. Data were collected through questionnaires and on-site physical examinations. The growth patterns and velocity of height and FL in different age groups were described, and their associations with puberty development were analyzed. Results From an age perspective, the peak FL growth occurred between 9 and 11 years (boys were 11 years and girls were 9 years), while the peak height growth occurred at 11 ~ 13 years for boys and 9 ~ 11 years for girls. Additionally, boys and girls reached 99.0% of their final FL at the ages of 14 and 13, respectively, while they reached 99.0% of their final height at the ages of 16 and 15, respectively. From the perspective of Tanner stage, the age of peak FL growth in boys coincided with the age of the G2 stage, while in girls it occurred slightly earlier than the mean age of the B2 stage. The peak height growth for both boys and girls occurred between Tanner stages 2 and 3. Conclusion Boys and girls reach their peak FL growth at 11 and 9 years old, respectively, which were both 2 years earlier than their peak height growth. The peak FL growth occurred around the onset of puberty, while the peak height growth occurred between Tanner stages 2 and 3.
Collapse
|
2
|
Zhang LY, Yick KL, Yue MJ, Yip J, Ng SP. An exploratory study of dynamic foot shape measurements with 4D scanning system. Sci Rep 2023; 13:8628. [PMID: 37244970 DOI: 10.1038/s41598-023-35822-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 05/24/2023] [Indexed: 05/29/2023] Open
Abstract
Accurate and reliable foot measurements at different stances offer comprehensive geometrical information on foot, thus enabling a more comfortable insole/footwear for practical use and daily activities. However, there lacks investigations on continuous deformation of foot shape during the roll-over process. This study analyses the foot deformation of 19 female diabetic patients during half weight bearing standing and self-selected walking speed by using a novel 4D foot scanning system. The scanning system has good repeatability and accuracy in both static and dynamic scanning situations. Point cloud registration for scanned image reorientation and algorithms to automatically extract foot measurements is developed. During the foot roll-over process, maximum deformation of length and girth dimensions are found at first toe contact. Width dimensions have maximum deformation at heel take off. The findings provide a new understanding of foot shape changes in dynamic situations, thus providing an optimal solution for foot comfort, function and protection.
Collapse
Affiliation(s)
- Li-Ying Zhang
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China
- Laboratory for Artificial Intelligence in Design, Hong Kong Science Park, New Territories, Hong Kong, China
| | - Kit-Lun Yick
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China.
- Laboratory for Artificial Intelligence in Design, Hong Kong Science Park, New Territories, Hong Kong, China.
| | - Mei-Jun Yue
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China
| | - Joanne Yip
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China
| | - Sun-Pui Ng
- School of Professional Education and Executive Development, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China
| |
Collapse
|
3
|
Wang Y, Jiang H, Yu L, Gao Z, Liu W, Mei Q, Gu Y. Understanding the Role of Children's Footwear on Children's Feet and Gait Development: A Systematic Scoping Review. Healthcare (Basel) 2023; 11:healthcare11101418. [PMID: 37239704 DOI: 10.3390/healthcare11101418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 04/29/2023] [Accepted: 05/09/2023] [Indexed: 05/28/2023] Open
Abstract
Children's footwear plays an important role in the healthy growth of foot and gait development during the growing stage. This review aims to synthesize findings of previous investigations and to explore the biomechanical influences of different types of children's footwear on foot health and gait development, thus guiding the healthy and safe growth of children's feet and gait. Online databases were searched for potential eligible articles, including Web of Science, Google Scholar, and PubMed. In total, nineteen articles were identified after searching based on the inclusion requirements. The following five aspects of biomechanical parameters were identified in the literature, including spatiotemporal, kinematics, kinetics, electromyography (EMG), and plantar pressure distribution. Children's footwear can affect their foot health and gait performance. In addition, children's shoes with different flexibility and sole hardness have different effects on children's feet and gait development. Compared to barefoot, the stride length, step length, stride time, and step time were increased, but cadence was decreased with wearing shoes. Furthermore, the support base and toe-off time increased. Double support time and stance time increased, but single support time decreased. The hip, knee, and ankle joints showed increased range of motion in children with the rear-foot strike with larger ground reaction force as well. Future studies may need to evaluate the influence of footwear types on gait performance of children in different age groups. Findings in this study may provide recommendations for suitable footwear types for different ages, achieving the aim of growth and development in a healthy and safe manner.
Collapse
Affiliation(s)
- Yuan Wang
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China
- Research Academy of Grand Health, Ningbo University, Ningbo 315211, China
| | - Hanhui Jiang
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China
- Research Academy of Grand Health, Ningbo University, Ningbo 315211, China
| | - Lin Yu
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China
| | - Zixiang Gao
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China
- Faculty of Engineering, University of Pannonia, 8200 Veszprém, Hungary
- Savaria Institute of Technology, Eötvös Loránd University, 9700 Szombathely, Hungary
| | - Wei Liu
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China
- Faculty of Engineering, University of Pannonia, 8200 Veszprém, Hungary
- Savaria Institute of Technology, Eötvös Loránd University, 9700 Szombathely, Hungary
| | - Qichang Mei
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China
- Research Academy of Grand Health, Ningbo University, Ningbo 315211, China
- Auckland Bioengineering Institute, The University of Auckland, Auckland 1010, New Zealand
| | - Yaodong Gu
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China
- Research Academy of Grand Health, Ningbo University, Ningbo 315211, China
| |
Collapse
|
4
|
Allan JJ, Munteanu SE, Bonanno DR, Buldt AK, Choppin S, Bullas A, Pearce N, Menz HB. Methodological and statistical approaches for the assessment of foot shape using three-dimensional foot scanning: a scoping review. J Foot Ankle Res 2023; 16:24. [PMID: 37106385 PMCID: PMC10134589 DOI: 10.1186/s13047-023-00617-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Accepted: 03/21/2023] [Indexed: 04/29/2023] Open
Abstract
OBJECTIVE The objectives of this study were to: (i) review and provide a narrative synthesis of three-dimensional (3D) foot surface scanning methodological and statistical analysis protocols, and (ii) develop a set of recommendations for standardising the reporting of 3D foot scanning approaches. METHODS A systematic search of the SCOPUS, ProQuest, and Web of Science databases were conducted to identify papers reporting 3D foot scanning protocols and analysis techniques. To be included, studies were required to be published in English, have more than ten participants, and involve the use of static 3D surface scans of the foot. Papers were excluded if they reported two-dimensional footprints only, 3D scans that did not include the medial arch, dynamic scans, or derived foot data from a full body scan. RESULTS The search yielded 78 relevant studies from 17 different countries. The available evidence showed a large variation in scanning protocols. The subcategories displaying the most variation included scanner specifications (model, type, accuracy, resolution, capture duration), scanning conditions (markers, weightbearing, number of scans), foot measurements and definitions used, and statistical analysis approaches. A 16-item checklist was developed to improve the consistency of reporting of future 3D scanning studies. CONCLUSION 3D foot scanning methodological and statistical analysis protocol consistency and reporting has been lacking in the literature to date. Improved reporting of the included subcategories could assist in data pooling and facilitate collaboration between researchers. As a result, larger sample sizes and diversification of population groups could be obtained to vastly improve the quantification of foot shape and inform the development of orthotic and footwear interventions and products.
Collapse
Affiliation(s)
- Jamie J Allan
- Discipline of Podiatry, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC, 3086, Australia.
| | - Shannon E Munteanu
- Discipline of Podiatry, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC, 3086, Australia
| | - Daniel R Bonanno
- Discipline of Podiatry, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC, 3086, Australia
| | - Andrew K Buldt
- Discipline of Podiatry, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC, 3086, Australia
| | - Simon Choppin
- Advanced Wellbeing Research Centre, Sheffield Hallam University, Sheffield, S9 3TU, UK
| | - Alice Bullas
- Advanced Wellbeing Research Centre, Sheffield Hallam University, Sheffield, S9 3TU, UK
| | - Natalie Pearce
- La Trobe Library, La Trobe University, Melbourne, VIC, 3086, Australia
| | - Hylton B Menz
- Discipline of Podiatry, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC, 3086, Australia
| |
Collapse
|
5
|
Abstract
Advancements in volumetric imaging makes it possible to generate high-resolution three-dimensional reconstructions of bones in throughout the foot and ankle. The use of weightbearing computed tomography allows for the analysis of joint relationships in a consistent natural position that can be used for statistical shape modeling. Using statistical shape modeling, a population-based statistical model is created that can be used to compare mean bone shape morphology and identify anatomical modes of variation. A review is presented to highlight the current work using statistical shape modeling in the foot and ankle with a future view of the impact on clinical care.
Collapse
|
6
|
Zhang LY, Liu QL, Yick KL, Yip J, Ng SP. Analysis of Diabetic Foot Deformation and Plantar Pressure Distribution of Women at Different Walking Speeds. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:3688. [PMID: 36834384 PMCID: PMC9965013 DOI: 10.3390/ijerph20043688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 02/17/2023] [Accepted: 02/17/2023] [Indexed: 06/18/2023]
Abstract
Official guidelines state that suitable physical activity is recommended for patients with diabetes mellitus. However, since walking at a rapid pace could be associated with increased plantar pressure and potential foot pain, the footwear condition is particularly important for optimal foot protection in order to reduce the risk of tissue injury and ulceration of diabetic patients. This study aims to analyze foot deformation and plantar pressure distribution at three different walking speeds (slow, normal, and fast walking) in dynamic situations. The dynamic foot shape of 19 female diabetic patients at three walking speeds is obtained by using a novel 4D foot scanning system. Their plantar pressure distributions at the three walking speeds are also measured by using the Pedar in-shoe system. The pressure changes in the toes, metatarsal heads, medial and lateral midfoot, and heel areas are systematically investigated. Although a faster walking speed shows slightly larger foot measurements than the two other walking speeds, the difference is insignificant. The foot measurement changes at the forefoot and heel areas, such as the toe angles and heel width, are found to increase more readily than the measurements at the midfoot. The mean peak plantar pressure shows a significant increase at a faster walking speed with the exception of the midfoot, especially at the forefoot and heel areas. However, the pressure time integral decreases for all of the foot regions with an increase in walking speed. Suitable offloading devices are essential for diabetic patients, particularly during brisk walking. Design features such as medial arch support, wide toe box, and suitable insole material for specific area of the foot (such as polyurethane for forefoot area and ethylene-vinyl acetate for heel area) are essential for diabetic insole/footwear to provide optimal fit and offloading. The findings contribute to enhancing the understanding of foot shape deformation and plantar pressure changes during dynamic situations, thus facilitating the design of footwear/insoles with optimal fit, wear comfort, and foot protection for diabetic patients.
Collapse
Affiliation(s)
- Li-Ying Zhang
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong, China
- Laboratory for Artificial Intelligence in Design, Hong Kong Science Park, Hong Kong, China
| | - Qi-Long Liu
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong, China
| | - Kit-Lun Yick
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong, China
- Laboratory for Artificial Intelligence in Design, Hong Kong Science Park, Hong Kong, China
| | - Joanne Yip
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong, China
| | - Sun-Pui Ng
- School of Professional Education and Executive Development, The Hong Kong Polytechnic University, Hong Kong, China
| |
Collapse
|
7
|
Boryczka-Trefler A, Kalinowska M, Szczerbik E, Stępowska J, Łukaszewska A, Syczewska M. How to Define Pediatric Flatfoot: Comparison of 2 Methods: Foot Posture in Static and Dynamic Conditions in Children 5 to 9 Years Old. Foot Ankle Spec 2023; 16:43-49. [PMID: 33605152 DOI: 10.1177/1938640021991345] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
LEVELS OF EVIDENCE Prospective cohort study.
Collapse
Affiliation(s)
- Anna Boryczka-Trefler
- Department of Rehabilitation, The Children's Memorial Health Institute, Warszawa, Poland
| | - Małgorzata Kalinowska
- Department of Rehabilitation, The Children's Memorial Health Institute, Warszawa, Poland
| | - Ewa Szczerbik
- Department of Rehabilitation, The Children's Memorial Health Institute, Warszawa, Poland
| | - Jolanta Stępowska
- Department of Rehabilitation, The Children's Memorial Health Institute, Warszawa, Poland
| | - Anna Łukaszewska
- Department of Rehabilitation, The Children's Memorial Health Institute, Warszawa, Poland
| | - Małgorzata Syczewska
- Department of Rehabilitation, The Children's Memorial Health Institute, Warszawa, Poland
| |
Collapse
|
8
|
Jiao Y, Džeroski S, Jurca A. Analysis of hallux valgus angles automatically extracted from 3D foot scans taken in North America, Europe, and Asia. ERGONOMICS 2022:1-12. [PMID: 36269073 DOI: 10.1080/00140139.2022.2139415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 10/17/2022] [Indexed: 06/16/2023]
Abstract
The forefoot is the foot part most affected by ill-fitting shoes. Footwear fitting considers the measurements of length, width, and arch length. Toe shape has not yet been used in sizing feet and fitting shoes. This study aims to investigate the variation in toe shape, as measured by the hallux valgus angle. An automatic and reproducible hallux valgus angle measuring method using 3D foot scans with no palpation markers is proposed and applied to about half a million samples collected across North America, Europe, and Asia. The measuring method is robust and can detect the medial contour along the proximal phalanx even in extreme cases. The hallux valgus angle has a normal distribution with long tails on both sides in the general population. Large dispersions of HVA values were observed for both genders and in all three geographical regions. Practitioner summary: The hallux valgus angle has a broad distribution in the general population. Females have larger hallux valgus angles than males, and people from Asia have larger hallux valgus angles than people from North America and Europe. Shoe toe boxes should be designed to fit the actual shapes of shoppers' toes. The proposed method for measuring HVA opens a new opportunity to study the causal relationship between shoe wearing habits and HVA on a large scale.
Collapse
Affiliation(s)
| | - Sašo Džeroski
- Jozef Stefan Institute, Ljubljana, Slovenia
- Jozef Stefan International Postgraduate School, Ljubljana, Slovenia
| | - Ales Jurca
- Volumental AB, Stockholm, Sweden
- Jozef Stefan International Postgraduate School, Ljubljana, Slovenia
| |
Collapse
|
9
|
Gimunová M, Kolářová K, Vodička T, Bozděch M, Zvonař M. How barefoot and conventional shoes affect the foot and gait characteristics in toddlers. PLoS One 2022; 17:e0273388. [PMID: 35998149 PMCID: PMC9398026 DOI: 10.1371/journal.pone.0273388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 08/08/2022] [Indexed: 11/18/2022] Open
Abstract
Objectives Barefoot shoes have recently become a popular alternative to conventional shoes among the parents of pre-school children. As the long-term effect of habitual shoe-wearing on the foot is still unclear, the aim of this study was to compare the arch index, dynamic foot anthropometry and gait parameters in toddlers who had been habitually wearing barefoot shoes or conventional shoes since their first steps. Methods 30 toddlers– 15 habitually wearing barefoot shoes (BF group) and 15 habitually wearing conventional shoes (N-BF group)–participated in this study. Each child was measured twice during the study. The first data collection session occurred within one month after the first five consecutive unsupported steps were performed by the toddler. The second data collection session occurred seven months after this event. At each data collection session, the toddler was instructed to walk barefooted at its natural speed over an Emed® platform (Novel GmbH, Germany). The Emed ® software generated data regarding the arch index, dynamic foot anthropometry, foot progression angle, contact area, contact time, peak pressure and maximum force. The Wilcoxon signed-rank test was used to compare the differences between the 1st and 2nd data collections. The Mann-Whitney U test was used to compare the differences between the BF and N-BF groups. Results The results of this study show a higher plantar arch and a smaller foot progression angle in the BF group. The forefoot width in both the BF and N-BF groups remained proportional to the foot length after seven months of independent walking. Conclusions These findings may encourage parents and caregivers to introduce barefoot shoes or create a habitual barefoot time for their child.
Collapse
Affiliation(s)
- Marta Gimunová
- Department of Kinesiology, Faculty of Sport Studies, Masaryk University, Brno, Czech Republic
- * E-mail:
| | - Kateřina Kolářová
- University Sport Centre, Faculty of Sport Studies, Masaryk University, Brno, Czech Republic
| | - Tomáš Vodička
- Department of Kinesiology, Faculty of Sport Studies, Masaryk University, Brno, Czech Republic
| | - Michal Bozděch
- Department of Kinesiology, Faculty of Sport Studies, Masaryk University, Brno, Czech Republic
| | - Martin Zvonař
- Department of Kinesiology, Faculty of Sport Studies, Masaryk University, Brno, Czech Republic
| |
Collapse
|
10
|
Brognara L, Fantini M, Morellato K, Graziani G, Baldini N, Cauli O. Foot Orthosis and Sensorized House Slipper by 3D Printing. MATERIALS 2022; 15:ma15124064. [PMID: 35744123 PMCID: PMC9231166 DOI: 10.3390/ma15124064] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2022] [Revised: 06/03/2022] [Accepted: 06/04/2022] [Indexed: 02/05/2023]
Abstract
BACKGROUND In clinical practice, specific customization is needed to address foot pathology, which must be disease and patient-specific. To date, the traditional methods for manufacturing custom functional Foot Orthoses (FO) are based on plaster casting and manual manufacturing, hence orthotic therapy depends entirely on the skills and expertise of individual practitioners. This makes the procedures difficult to standardize and replicate, as well as expensive, time-consuming and material-wasting, as well as difficult to standardize and replicate. 3D printing offers new perspectives in the development of patient-specific orthoses, as it permits addressing all the limitations of currently available technologies, but has been so far scarcely explored for the podiatric field, so many aspects remain unmet, especially for what regards customization, which requires the definition of a protocol that entails all stages from patient scanning to manufacturing. METHODS A feasibility study was carried out involving interdisciplinary cooperation between industrial engineers and podiatrists. To that end: (i) For patient-specific data acquisition, 3D scanning of the foot is compared to traditional casting. (ii) a modelling GD workflow is first created to design a process permitting easy creations of customized shapes, enabling the end user (the podiatrist) to interactively customize the orthoses. Then, (iii) a comparison is made between different printing materials, in order to reproduce the same mechanical behavior shown by standard orthoses. To do this, the mechanical properties of standard materials (Polycarbonate sheets), cut and hand-shaped, are compared with four groups of 3D printed samples: poly(ethylene glycol) (PETG), poly(acrylonitrile-butadiene.styrene) (ABS), polycarbonate (PC) and poly(lactic acid) (PLA) obtained by Fused Filament Fabrication (FFF). RESULTS Differences found between the foot plaster model obtained with the plaster slipper cast in a neutral position and the model of the real foot obtained with 3D scanning in the same position can be ascribed to the non-stationarity of the patient during the acquisition process, and were limited by a locking system with which no substantial differences in the almost entire sole of the foot scan were observed. CONCLUSIONS Using the designed GD workflow, podiatrists with limited CAD skills can easily design and interactively customize foot orthoses to adapt them to the patients' clinical needs. 3D printing enables the complex shape of the orthoses to be reproduced easily and quickly. Compared to Polycarbonate sheets (gold standard), all the printed materials were less deformable and reached lower yield stress for comparable deformation. No modifications in any of the materials as a result of printing process were observed.
Collapse
Affiliation(s)
- Lorenzo Brognara
- Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, 40123 Bologna, Italy;
| | | | - Kavin Morellato
- Department of Industrial Engineering, Alma Mater Studiorum, University of Bologna, Via Terracini 28, 40131 Bologna, Italy;
| | - Gabriela Graziani
- Laboratory of Nanobiotechnology, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy;
| | - Nicola Baldini
- Biomedical Science and Technologies Lab, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy;
| | - Omar Cauli
- Nursing Department, University of Valencia, Avda Menendez Pelayo 19, 46010 Valencia, Spain
- Frailty Research Organizad Group, University of Valencia, Avda Menendez Pelayo 19, 46010 Valencia, Spain
- Correspondence:
| |
Collapse
|
11
|
Matthias E, Banwell HA, Arnold JB. Children's school footwear: The impact of fit on foot function, comfort and jump performance in children aged 8 to 12 years. Gait Posture 2021; 87:87-94. [PMID: 33895636 DOI: 10.1016/j.gaitpost.2021.04.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 04/07/2021] [Accepted: 04/14/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND There is a common perception that poorly fitting footwear will negatively impact a child's foot, however, there is limited evidence to support this. AIM To determine the effect of shoe size on foot motion, perceived footwear comfort and fit during walking, maximal vertical jump height and maximal standing broad jump distance in children aged 8-12 years. METHODS Fourteen participants completed 3D walking gait analysis and jumping tasks in three different sizes of school shoes (one size bigger, fitted for size, one size smaller). In-shoe motion of the hindfoot, midfoot and 1st metatarsophalangeal joint (1st MTPJ) were calculated using a multi-segment kinematic foot model. Physical performance measures were calculated via maximal vertical jump and maximal standing broad jump. Perceived footwear comfort and fit (heel, toes and overall) was assessed using a 100 mm visual analog scale (VAS). Differences were compared between shoe sizes using repeated measures ANOVA, post-hoc tests and effect sizes (Cohen's d). RESULTS Compared to the fitted footwear, the smaller sizing restricted hindfoot eversion (-2.5°, p = 0.021, d = 0.82), 1st MTPJ dorsiflexion (-3.9°, p = 0.012, d = 0.54), and compared to the bigger footwear, smaller sizing restricted sagittal plane midfoot range-of-motion during walking (-2.5°, p = 0.047, d = 0.59). The fitted footwear was rated as more comfortable overall with the smaller size rated as too tight in both the heel (mean difference 11.5 mm, p = 0.042, d = 0.58) and toes (mean difference 12.1 mm, p = 0.022, d = 0.59), compared to the fitted size. Vertical and standing broad jump distance were not impacted by footwear size (p = 0.218-0.836). SIGNIFICANCE Footwear that is too small restricts foot motion during walking in children aged 8-12 years. Jump performance was not affected. Children were able to recognise shoes that were not correctly matched to their foot length, reinforcing that comfort is an important part of the fitting process.
Collapse
Affiliation(s)
- Elsa Matthias
- Alliance for Research in Exercise, Nutrition and Activity (ARENA), Allied Health & Human Performance, University of South Australia, Adelaide, Australia.
| | - Helen Ann Banwell
- Allied Health and Human Performance, University of South Australia, Adelaide, Australia.
| | - John Bradley Arnold
- Alliance for Research in Exercise, Nutrition and Activity (ARENA), Allied Health & Human Performance, University of South Australia, Adelaide, Australia; IIMPACT in Health, Allied Health & Human Performance, University of South Australia, Adelaide, Australia.
| |
Collapse
|
12
|
Boppana A, Anderson AP. Dynamic foot morphology explained through 4D scanning and shape modeling. J Biomech 2021; 122:110465. [PMID: 33964577 DOI: 10.1016/j.jbiomech.2021.110465] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 03/20/2021] [Accepted: 04/14/2021] [Indexed: 12/14/2022]
Abstract
A detailed understanding of foot morphology can enable the design of more comfortable and better fitting footwear. However, foot morphology varies widely within the population, and changes dynamically as the foot is loaded during stance. This study presents a parametric statistical shape model from 4D foot scans to capture both the inter- and intra-individual variability in foot morphology. Thirty subjects walked on a treadmill while 4D scans of their right foot were taken at 90 frames-per second during stance phase. Each subject's height, weight, foot length, foot width, arch length, and sex were also recorded. The 4D scans were all registered to a common high-quality foot scan, and a principal component analysis was done on all processed 4D scans. Elastic-net linear regression models were built to predict the principal component scores, which were then inverse transformed into 4D scans. The best performing model was selected with leave-one-out cross-validation. The chosen model predicts foot morphology across stance phase with a root-mean-square error of 5.2 ± 2.0 mm and a mean Hausdorff distance of 25.5 ± 13.4 mm. This study shows that statistical shape modeling can be used to predict dynamic changes in foot morphology across the population. The model can be used to investigate and improve foot-footwear interaction, allowing for better fitting and more comfortable footwear.
Collapse
Affiliation(s)
- Abhishektha Boppana
- Ann and H.J. Smead Department of Aerospace Engineering Sciences, University of Colorado Boulder, USA.
| | - Allison P Anderson
- Ann and H.J. Smead Department of Aerospace Engineering Sciences, University of Colorado Boulder, USA
| |
Collapse
|
13
|
A Cross-Sectional Study of Foot Growth and Its Correlation with Anthropometric Parameters in a Representative Cohort of Schoolchildren from Southern Spain. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18084031. [PMID: 33921266 PMCID: PMC8068955 DOI: 10.3390/ijerph18084031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 04/02/2021] [Accepted: 04/10/2021] [Indexed: 02/04/2023]
Abstract
Background: The relationship between growth of the foot and other anthropometric parameters during body development until puberty has been scarcely studied. Some studies propose that growth of the foot in length may be an early index of puberty. The objective of this cross-sectional study was to analyze the relationship between the growth of the foot in length and width with other anthropometric parameters, in prepubertal and early pubertal schoolchildren (Tanner stage II). Methods: Using an instrument that was designed and calibrated for this purpose, maximum foot length, width and height were obtained in 1005 schoolchildren. Results: The findings indicate that the age of onset of pubertal foot growth spur was 7–8 years in girls, and 8–9 years in boys. Growth in foot length stabilized in both sexes after 12 years of age. In boys, a strong correlation was found between height and foot length (r = 0.884; p < 0.047), and between body mass index (BMI) and forefoot width at 12 years of age (r = 0.935; p < 0.020). A strong correlation was found between height and forefoot width at 6 years in girls (r = 0.719; p < 0.001), as well as between BMI and metatarsal width in 10 years-old girls (r = 0.812; p <0.001). Conclusions: The average increase in foot length and width that precedes the onset of Tanner’s stage II in both girls and boys can be considered as a useful biological indicator of the onset of puberty.
Collapse
|
14
|
Jones PJ, Bibb RJ, Davies MJ, Khunti K, McCarthy M, Fong DTP, Webb D. A fitting problem: Standardising shoe fit standards to reduce related diabetic foot ulcers. Diabetes Res Clin Pract 2019; 154:66-74. [PMID: 31128134 DOI: 10.1016/j.diabres.2019.05.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Accepted: 05/15/2019] [Indexed: 12/21/2022]
Abstract
AIMS Incorrectly fitting shoes are implicated in callus formation and a significant proportion of diabetic foot ulcers, yet remain surprisingly prevalent. We review the current shoe fit guidelines for consistency and discuss ways in which technology may assist us in standardising methods of footwear assessment. METHODS Narrative review. RESULTS Incorrectly fitted shoes are implicated in the development of some diabetic foot ulcers yet surprisingly there's no consensus on shoe fit, despite substantial spending on prescription footwear. Suggested toe gaps vary from 6 to 20 mm and measurement methods also vary from Brannock Devices and callipers to manual measurement. CONCLUSIONS To prevent fit-related foot ulceration, we need to standardise our biomechanical definition of fit. Future research should (1) evaluate the potential use of 3D scanning technology to provide a standardised means of capturing foot morphology; (2) develop a working biomechanical definition of fit, including toe gap through the identification of key physiological markers that capture and predict dynamic foot shape changes during different physical activities and body weight loading conditions; and (3) determine whether changes in dynamic foot shape of those with diabetes differs from those without, impacting on their shoe fitting needs, potentially necessitating specialist footwear at an earlier stage to avoid ulceration.
Collapse
Affiliation(s)
- Petra J Jones
- Leicester Diabetes Centre, Leicester General Hospital, Leicester, UK.
| | - Richard J Bibb
- Loughborough Design School, Loughborough University, Loughborough, UK
| | - Melanie J Davies
- Leicester Diabetes Centre, Leicester General Hospital, Leicester, UK
| | - Kamlesh Khunti
- Leicester Diabetes Centre, Leicester General Hospital, Leicester, UK
| | - Matthew McCarthy
- Leicester Diabetes Centre, Leicester General Hospital, Leicester, UK
| | - Daniel T P Fong
- School of Sport, Exercise and Health Sciences, Loughborough University, UK
| | - David Webb
- Leicester Diabetes Centre, Leicester General Hospital, Leicester, UK
| |
Collapse
|
15
|
Footwear fit in schoolchildren of southern Spain: a population study. BMC Musculoskelet Disord 2019; 20:208. [PMID: 31077163 PMCID: PMC6511213 DOI: 10.1186/s12891-019-2591-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Accepted: 04/26/2019] [Indexed: 11/10/2022] Open
Abstract
Background Recent studies support the theory that ill-fitting shoes are an important source of pain and may lead to foot malformations in the medium term. Taking as reference the ideal allowance considered in the literature, the purpose of this study was to verify the outdoor footwear fit in a population of schoolchildren of southern Spain. Methods Five hundred and five children within the range of 3–12 years of age participated in this study. Using a measuring instrument designed and validated for this purpose, maximum foot length, width and height were obtained from the longest foot. These measurements were compared with the inner length, width and height of the footwear. An adequate toe allowance of 5–15 mm in length and 10 mm in width were estimated. Results Inner footwear length was shorter than foot length in 33.3% of the schoolchildren. Based on the allowance established, it was observed that the footwear of the schoolchildren was too short and too narrow in 72.5 and 66.7% of the cases, respectively. Conclusions Only one third of the participants analysed had well-fitted footwear. The results show that it is necessary to raise awareness among parents and teachers about the importance of replacing, periodically, the footwear of children in primary education. Manufacturers should adapt the lasts considering the use of 90th percentiles instead of mean values obtained from the growth curves of schoolchildren’s feet.
Collapse
|
16
|
Hill M, Healy A, Chockalingam N. Key concepts in children's footwear research: a scoping review focusing on therapeutic footwear. J Foot Ankle Res 2019; 12:25. [PMID: 31061678 PMCID: PMC6487054 DOI: 10.1186/s13047-019-0336-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2018] [Accepted: 04/11/2019] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Reports suggest that children with mobility impairment represent a significant proportion of the population living with a disability. Footwear is considered to be the key extrinsic factor affecting children's gait and footwear modifications have been historically postulated to assist with locomotory difficulty. Although therapeutic footwear has been considered within the literature, there is a lack of consistency on terminology and paucity on the overall understanding. A scoping review was performed to chart the key concepts in children's footwear and to establish the range of studies that considered therapeutic footwear. METHODS A systematic search of MEDLINE, CINAHL, PubMed, SPORTdiscus, and Scopus electronic databases was performed using MeSH headings and free text terms in relation to children's footwear. All studies that used footwear as an intervention in children aged 9 months to 18 years with the outcome measures including design, fit, and the effects on development and health were included. Studies were charted by textual narrative synthesis into research groupings dependent on the topics discussed and the methods used in the studies. RESULTS The search yielded a total of 5006 articles with 287 of these articles meeting the inclusion criteria. Two overarching areas of research were identified; articles that discussed footwear design and those that discussed the effects of footwear. Eight further general groupings were charted and apportioned between the overarching areas and therapeutic footwear was charted into three subgroupings (corrective, accommodative and functional). CONCLUSION Children's footwear has become an increasing area of research in the past decade with a shift towards more empirical research, with most of the included articles examining biomechanical and anthropometric aspects. However, children's therapeutic footwear has not shared the same recent impetus with no focused review and limited research exploring its effects. Empirical research in this area is limited and there is ambiguity in the terminology used to describe therapeutic footwear. Based on the findings of this review the authors suggest the term children's therapeutic footwear be used as the standard definition for footwear that is designed specifically with the purpose to support or alleviate mobility impairment in childhood; with subgroupings of corrective, accommodative and functional dependent on the intended therapeutic role.
Collapse
Affiliation(s)
- Matthew Hill
- Centre for Biomechanics and Rehabilitation Technologies, Staffordshire University, Stoke on Trent, ST4 2DF UK
| | - Aoife Healy
- Centre for Biomechanics and Rehabilitation Technologies, Staffordshire University, Stoke on Trent, ST4 2DF UK
| | - Nachiappan Chockalingam
- Centre for Biomechanics and Rehabilitation Technologies, Staffordshire University, Stoke on Trent, ST4 2DF UK
| |
Collapse
|
17
|
Grau S, Barisch-Fritz B. Improvement of safety shoe fit - evaluation of dynamic foot structure. FOOTWEAR SCIENCE 2018. [DOI: 10.1080/19424280.2018.1529062] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Affiliation(s)
- Stefan Grau
- Department of Food and Nutrition and Sport Science, University of Gothenburg, Göteborg, Sweden
- Department of Sports Medicine, University Clinic Tübingen, Tübingen, Germany
| | - Bettina Barisch-Fritz
- Department of Sports Medicine, University Clinic Tübingen, Tübingen, Germany
- Institute of Sports and Sports Science, Karlsruhe Institute of Technology, Karlsruhe, Germany
| |
Collapse
|
18
|
Morrison SC, Price C, McClymont J, Nester C. Big issues for small feet: developmental, biomechanical and clinical narratives on children's footwear. J Foot Ankle Res 2018; 11:39. [PMID: 30002732 PMCID: PMC6034280 DOI: 10.1186/s13047-018-0281-2] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Accepted: 06/25/2018] [Indexed: 11/10/2022] Open
Abstract
The effects of footwear on the development of children's feet has been debated for many years and recent work from the developmental and biomechanical literature has challenged long-held views about footwear and the impact on foot development. This narrative review draws upon existing studies from developmental, biomechanical and clinical literature to explore the effects of footwear on the development of the foot. The emerging findings from this support the need for progress in [children's] footwear science and advance understanding of the interaction between the foot and shoe. Ensuring clear and credible messages inform practice requires a progressive evidence base but this remains big issue in children's footwear research.
Collapse
Affiliation(s)
- Stewart C Morrison
- 1School of Health Sciences, University of Brighton, 49 Darley Road, Eastbourne Campus, BN20 7UR UK
| | - Carina Price
- 2Centre for Health Research, University of Salford, Salford, UK
| | - Juliet McClymont
- 1School of Health Sciences, University of Brighton, 49 Darley Road, Eastbourne Campus, BN20 7UR UK
| | - Chris Nester
- 2Centre for Health Research, University of Salford, Salford, UK
| |
Collapse
|
19
|
Banwell HA, Paris ME, Mackintosh S, Williams CM. Paediatric flexible flat foot: how are we measuring it and are we getting it right? A systematic review. J Foot Ankle Res 2018; 11:21. [PMID: 29854006 PMCID: PMC5975578 DOI: 10.1186/s13047-018-0264-3] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Accepted: 05/11/2018] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND Flexible flat foot is a normal observation in typically developing children, however, some children with flat feet present with pain and impaired lower limb function. The challenge for health professionals is to identify when foot posture is outside of expected findings and may warrant intervention. Diagnoses of flexible flat foot is often based on radiographic or clinical measures, yet the validity and reliability of these measures for a paediatric population is not clearly understood. The aim of this systematic review was to investigate how paediatric foot posture is defined and measured within the literature, and if the psychometric properties of these measures support any given diagnoses. METHODS Electronic databases (MEDLINE, CINAHL, EMBASE, Cochrane, AMED, SportDiscus, PsycINFO, and Web of Science) were systematically searched in January 2017 for empirical studies where participants had diagnosed flexible flat foot and were aged 18 years or younger. Outcomes of interest were the foot posture measures and definitions used. Further articles were sought where cited in relation to the psychometric properties of the measures used. RESULTS Of the 1101 unique records identified by the searches, 27 studies met the inclusion criteria involving 20 foot posture measures and 40 definitions of paediatric flexible flat foot. A further 18 citations were sought in relation to the psychometric properties of these measures. Three measures were deemed valid and reliable, the FPI-6 > + 6 for children aged three to 15 years, a Staheli arch index of > 1.07 for children aged three to six and ≥ 1.28 for children six to nine, and a Chippaux-Smirak index of > 62.7% in three to seven year olds, > 59% in six to nine year olds and ≥ 40% for children aged nine to 16 years. No further measures were found to be valid for the paediatric population. CONCLUSION No universally accepted criteria for diagnosing paediatric flat foot was found within existing literature, and psychometric data for foot posture measures and definitions used was limited. The outcomes of this review indicate that the FPI - 6, Staheli arch index or Chippaux-Smirak index should be the preferred method of paediatric foot posture measurement in future research.
Collapse
Affiliation(s)
- Helen A. Banwell
- International Centre for Allied Health Evidence, University of South Australia, Adelaide, South Australia 5001 Australia
- School of Health Sciences, University of South Australia, Adelaide, South Australia 5001 Australia
| | - Maisie E. Paris
- International Centre for Allied Health Evidence, University of South Australia, Adelaide, South Australia 5001 Australia
| | - Shylie Mackintosh
- School of Health Sciences, University of South Australia, Adelaide, South Australia 5001 Australia
| | - Cylie M. Williams
- School of Health Sciences, University of South Australia, Adelaide, South Australia 5001 Australia
- Allied Health, Peninsula Health, Frankston, VIC 3199 Australia
- School of Primary and Allied Health, Monash University, Frankston, VIC 3199 Australia
| |
Collapse
|
20
|
Dobson JA, Riddiford-Harland DL, Bell AF, Steele JR. The three-dimensional shapes of underground coal miners' feet do not match the internal dimensions of their work boots. ERGONOMICS 2018; 61:588-602. [PMID: 29065793 DOI: 10.1080/00140139.2017.1397201] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2017] [Accepted: 10/04/2017] [Indexed: 06/07/2023]
Abstract
Mining work boots provide an interface between the foot and the ground, protecting and supporting miners' feet during lengthy coal mining shifts. Although underground coal miners report the fit of their work boots as reasonable to good, they frequently rate their boots as uncomfortable, suggesting that there is a mismatch between the shape of their feet and their boots. This study aimed to identify whether dimensions derived from the three-dimensional scans of 208 underground coal miners' feet (age 38.3 ± 9.8 years) differed from the internal dimensions of their work boots. The results revealed underground coal miners wore boots that were substantially longer than their feet, possibly because boots available in their correct length were too narrow. It is recommended boot manufacturers reassess the algorithms used to create boot lasts, focusing on adjusting boot circumference at the instep and heel relative to increases in foot length. Practitioner Summary: Fit and comfort ratings suggest a mismatch between the shape of underground coal miners' feet and their boots exists. This study examined whether three-dimensional scans of 208 miners' feet differed from their boot internal dimensions. Miners wore boots substantially longer than their feet, possibly due to inadequate width.
Collapse
Affiliation(s)
- Jessica A Dobson
- a Biomechanics Research Laboratory, Faculty of Science, Medicine & Health, School of Medicine , University of Wollongong , Wollongong , Australia
| | - Diane L Riddiford-Harland
- a Biomechanics Research Laboratory, Faculty of Science, Medicine & Health, School of Medicine , University of Wollongong , Wollongong , Australia
| | - Alison F Bell
- b School of Health & Society, Faculty of Social Sciences , University of Wollongong , Wollongong , Australia
| | - Julie R Steele
- a Biomechanics Research Laboratory, Faculty of Science, Medicine & Health, School of Medicine , University of Wollongong , Wollongong , Australia
| |
Collapse
|
21
|
Grau S, Barisch-Fritz B. Improvement of fit of security shoes – evaluation of dynamic foot structure. FOOTWEAR SCIENCE 2017. [DOI: 10.1080/19424280.2017.1314322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Stefan Grau
- Department of Food and Nutrition, and Sport Science, University of Gothenburg, Göteborg, Sweden
- Department of Sports Medicine, University Clinic Tübingen, Germany
| | - Bettina Barisch-Fritz
- Department of Sports Medicine, University Clinic Tübingen, Germany
- Institute of Sports and Sports Science, Karlsruhe Institute of Technology, Karlsruhe, Germany
| |
Collapse
|
22
|
Tsao L, Ma L. Using subject-specific three-dimensional (3D) anthropometry data in digital human modelling: case study in hand motion simulation. ERGONOMICS 2016; 59:1526-1539. [PMID: 26857691 DOI: 10.1080/00140139.2016.1151554] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Digital human modelling enables ergonomists and designers to consider ergonomic concerns and design alternatives in a timely and cost-efficient manner in the early stages of design. However, the reliability of the simulation could be limited due to the percentile-based approach used in constructing the digital human model. To enhance the accuracy of the size and shape of the models, we proposed a framework to generate digital human models using three-dimensional (3D) anthropometric data. The 3D scan data from specific subjects' hands were segmented based on the estimated centres of rotation. The segments were then driven in forward kinematics to perform several functional postures. The constructed hand models were then verified, thereby validating the feasibility of the framework. The proposed framework helps generate accurate subject-specific digital human models, which can be utilised to guide product design and workspace arrangement. Practitioner Summary: Subject-specific digital human models can be constructed under the proposed framework based on three-dimensional (3D) anthropometry. This approach enables more reliable digital human simulation to guide product design and workspace arrangement.
Collapse
Affiliation(s)
- Liuxing Tsao
- a Department of Industrial Engineering , Tsinghua University , Beijing , China
| | - Liang Ma
- a Department of Industrial Engineering , Tsinghua University , Beijing , China
| |
Collapse
|
23
|
Barisch-Fritz B, Plank C, Grau S. Evaluation of the rule-of-thumb: calculation of the toe allowance for developing feet. FOOTWEAR SCIENCE 2016. [DOI: 10.1080/19424280.2016.1144654] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|