1
|
Long Z, Zhao Z, Fan X, Luo X. Comparison of analytical-flow, micro-flow and nano-flow LC-MS/MS for sub-proteome analysis. J Pharm Biomed Anal 2025; 252:116484. [PMID: 39353257 DOI: 10.1016/j.jpba.2024.116484] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 09/11/2024] [Accepted: 09/22/2024] [Indexed: 10/04/2024]
Abstract
The accurate and sensitive analysis of sub-proteomic samples, such as host cell proteins (HCPs) in recombinant products and stem cells in medical devices, is crucial for ensuring product safety and efficacy in the biopharmaceutical industry. However, current analytical techniques, such as conventional analytical-flow LC-MS/MS, face limitations in sensitivity due to the low concentrations of target proteins and the complexity of the sample matrix. In this study, a highly sensitive and repeatable micro-flow LC-MS/MS strategy was developed by replacing analytical-flow tubing with micro-flow tubing on an existing analytical-flow LC-MS system for sub-proteomic sample analysis. Method optimization and evaluation were first conducted with monoclonal antibody (mAb) digestion, focusing on enhancing sensitivity and repeatability. Over 8 days, relative standard deviations (RSDs) for retention time and mass area were less than 5 % and 10 %, respectively. Sensitivity improved by 2.91-4.14 times compared to the analytical-flow LC-MS/MS method. After confirming the reliability of the method, the micro-flow LC-MS/MS method was compared to the nano-flow LC-MS/MS method and the analytical-flow LC-MS/MS method in sub-proteomic sample analysis. For HCPs, the micro-flow LC-MS/MS method demonstrated superior qualitative and much better reproducibility than the nano-flow LC-MS/MS method, with more than 98 % of proteins showing intensity RSD values below 20 %. In the analysis of mesenchymal stem cells (MSCs), the micro-flow method demonstrated good reproducibility and better sensitivity than the analytical-flow method. Taking the analysis of the 20th generation of MSC products as an example, the sample analyzed by micro-flow LC-MS/MS resulted in the identification of 68 % and 8.5 % more peptides and proteins, respectively. Moreover, micro-flow maintained stable system pressure while analyzing umbilical cord stem cells, where nano-flow methods often encounter blockages. This micro-flow LC-MS/MS method is notable for its sensitivity, reproducibility, and straightforward operation, making it highly adaptable for diverse sub-proteomic analyses in biopharmaceutical laboratories.
Collapse
Affiliation(s)
- Zhen Long
- ThermoFisher scientific corporation, Beijing 100080, China
| | - Zixi Zhao
- National Institutes for Food and Drug Control, Institute for Medical Devices Control, Beijing 102629, China
| | - Xingliang Fan
- National Institutes for Food and Drug Control, Institute for Medical Devices Control, Beijing 102629, China
| | - Xi Luo
- State Key Laboratory of Biochemical Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China; Key Laboratory of Biopharmaceutical Preparation and Delivery, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China.
| |
Collapse
|
2
|
Liang W, Zhu Z, Zheng C. Application of Proteomics Technology Based on LC-MS Combined with Western Blotting and Co-IP in Antiviral Innate Immunity. Methods Mol Biol 2025; 2854:93-106. [PMID: 39192122 DOI: 10.1007/978-1-0716-4108-8_11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/29/2024]
Abstract
As an interferon-stimulating factor protein, STING plays a role in the response and downstream liaison in antiviral natural immunity. Upon viral invasion, the immediate response of STING protein leads to a series of changes in downstream proteins, which ultimately leads to an antiviral immune response in the form of proinflammatory cytokines and type I interferons, thus triggering an innate immune response, an adaptive immune response in vivo, and long-term protection of the host. In the field of antiviral natural immunity, it is particularly important to rigorously and sequentially probe the dynamic changes in the antiviral natural immunity connector protein STING caused by the entire anti-inflammatory and anti-pathway mechanism and the differences in upstream and downstream proteins. Traditionally, proteomics technology has been validated by detecting proteins in a 2D platform, for which it is difficult to sensitively identify changes in the nature and abundance of target proteins. With the development of mass spectrometry (MS) technology, MS-based proteomics has made important contributions to characterizing the dynamic changes in the natural immune proteome induced by viral infections. MS analytical techniques have several advantages, such as high throughput, rapidity, sensitivity, accuracy, and automation. The most common techniques for detecting complex proteomes are liquid chromatography (LC) and mass spectrometry (MS). LC-MS (Liquid Chromatography-Mass Spectrometry), which combines the physical separation capability of LC and the mass analysis capability of MS, is a powerful technique mainly used for analyzing the proteome of cells, tissues, and body fluids. To explore the combination of traditional proteomics techniques such as Western blotting, Co-IP (co-Immunoprecipitation), and the latest LC-MS methods to probe the anti-inflammatory pathway and the differential changes in upstream and downstream proteins induced by the antiviral natural immune junction protein STING.
Collapse
Affiliation(s)
- Weizheng Liang
- Central Laboratory, The First Affiliated Hospital of Hebei North University, Zhangjiakou, Hebei, China
- Department of General Surgery, The First Affiliated Hospital of Hebei North University, Zhangjiakou, Hebei, China
| | - Zhenpeng Zhu
- Department of General Surgery, The First Affiliated Hospital of Hebei North University, Zhangjiakou, Hebei, China
| | - Chunfu Zheng
- Department of Microbiology, Immunology and Infectious Diseases, University of Calgary, Calgary, AB, Canada
| |
Collapse
|
3
|
Zahn E, Xie Y, Liu X, Karki R, Searfoss RM, de Luna Vitorino FN, Lempiäinen JK, Gongora J, Lin Z, Zhao C, Yuan ZF, Garcia BA. Development of a high-throughput platform for quantitation of histone modifications on a new QTOF instrument. Mol Cell Proteomics 2024:100897. [PMID: 39708910 DOI: 10.1016/j.mcpro.2024.100897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2024] [Revised: 12/12/2024] [Accepted: 12/13/2024] [Indexed: 12/23/2024] Open
Abstract
Histone post-translational modifications (PTMs) regulate gene expression patterns through epigenetic mechanisms. The 5 histone proteins (H1, H2A, H2B, H3, and H4) are extensively modified, with over 75 distinct modification types spanning more than 200 sites. Despite strong advances in mass spectrometry-based approaches, identification and quantification of modified histone peptides remains challenging due to factors such as isobaric peptides, pseudo-isobaric PTMs, and low stoichiometry of certain marks. Here we describe the development of a new high-throughput method to identify and quantify over 150 modified histone peptides by liquid chromatography-mass spectrometry (LC-MS). Fast gradient microflow liquid chromatography and variable window SWATH data-independent acquisition on a new quadrupole time-of-flight platform is compared to a previous method using nanoflow LC-MS on an Orbitrap hybrid. Histones extracted from cells treated with either a histone deacetylase inhibitor (HDACi) or TGF-beta 1 were analyzed by data-independent acquisition (DIA) on two mass spectrometers: an Orbitrap Exploris 240 with a 55-minute nanoflow LC gradient, and the SCIEX ZenoTOF 7600 with a 10-minute microflow gradient. To demonstrate the reproducibility and speed advantage of the method, 100 consecutive injections of one sample were performed in less than 2 days on the QTOF platform. The result is the comprehensive characterization of histone PTMs achieved in less than 20 minutes of total run time using only 200 ng of sample. Results for drug-treated histone samples are comparable to those produced by the previous method and can be achieved using less than one-third of the instrument time.
Collapse
Affiliation(s)
- Emily Zahn
- Department of Biochemistry and Molecular Biophysics, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - Yixuan Xie
- Department of Biochemistry and Molecular Biophysics, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - Xingyu Liu
- Department of Biochemistry and Molecular Biophysics, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - Rashmi Karki
- Department of Biochemistry and Molecular Biophysics, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - Richard M Searfoss
- Department of Biochemistry and Molecular Biophysics, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - Francisca N de Luna Vitorino
- Department of Biochemistry and Molecular Biophysics, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - Joanna K Lempiäinen
- Department of Biochemistry and Molecular Biophysics, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - Joanna Gongora
- Department of Biochemistry and Molecular Biophysics, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - Zongtao Lin
- Department of Biochemistry and Molecular Biophysics, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - Chenfeng Zhao
- Department of Computer Science and Engineering, Washington University in St. Louis, St. Louis, MO 63130, United States
| | - Zuo-Fei Yuan
- Center for Proteomics and Metabolomics, St. Jude Children's Research Hospital, Memphis, TN 38105, United States
| | - Benjamin A Garcia
- Department of Biochemistry and Molecular Biophysics, Washington University School of Medicine, St. Louis, Missouri 63110, United States.
| |
Collapse
|
4
|
Starovoit MR, Jadeja S, Gazárková T, Lenčo J. Mitigating In-Column Artificial Modifications in High-Temperature LC-MS for Bottom-Up Proteomics and Quality Control of Protein Biopharmaceuticals. Anal Chem 2024; 96:14531-14540. [PMID: 39196537 PMCID: PMC11391404 DOI: 10.1021/acs.analchem.4c02819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/29/2024]
Abstract
Elevating the column temperature is an effective strategy for improving the chromatographic separation of peptides. However, high temperatures induce artificial modifications that compromise the quality of the peptide analysis. Here, we present a novel high-temperature LC-MS method that retains the benefits of a high column temperature while significantly reducing peptide modification and degradation during reversed-phase liquid chromatography. Our approach leverages a short inline trap column maintained at a near-ambient temperature installed upstream of a separation column. The retentivity and dimensions of the trap column were optimized to shorten the residence time of peptides in the heated separation column without compromising the separation performance. This easy-to-implement approach increased peak capacity by 1.4-fold within a 110 min peptide mapping of trastuzumab and provided 10% more peptide identifications in exploratory LC-MS proteomic analyses compared with analyses conducted at 30 °C while maintaining the extent of modifications close to the background level. In the peptide mapping of biopharmaceuticals, where in-column modifications can falsely elevate the levels of some critical quality attributes, the method reduced temperature-related artifacts by 66% for N-terminal pyroGlu and 63% for oxidized Met compared to direct injection at 60 °C, thus improving reliability in quality control of protein drugs. Our findings represent a promising advancement in LC-MS methodology, providing researchers and industry professionals with a valuable tool for improving the chromatographic separation of peptides while significantly reducing the unwanted modifications.
Collapse
Affiliation(s)
- Mykyta R Starovoit
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 03 Hradec Králové, Czech Republic
| | - Siddharth Jadeja
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 03 Hradec Králové, Czech Republic
| | - Taťána Gazárková
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 03 Hradec Králové, Czech Republic
| | - Juraj Lenčo
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 03 Hradec Králové, Czech Republic
| |
Collapse
|
5
|
Gotti C, Roux-Dalvai F, Bérubé È, Lacombe-Rastoll A, Leclercq M, Jacob CC, Boissinot M, Martins C, Wijeratne NR, Bergeron MG, Droit A. LC-SRM Combined With Machine Learning Enables Fast Identification and Quantification of Bacterial Pathogens in Urinary Tract Infections. Mol Cell Proteomics 2024; 23:100832. [PMID: 39178943 PMCID: PMC11532907 DOI: 10.1016/j.mcpro.2024.100832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2024] [Revised: 08/16/2024] [Accepted: 08/20/2024] [Indexed: 08/26/2024] Open
Abstract
Urinary tract infections (UTIs) are a worldwide health problem. Fast and accurate detection of bacterial infection is essential to provide appropriate antibiotherapy to patients and to avoid the emergence of drug-resistant pathogens. While the gold standard requires 24 h to 48 h of bacteria culture prior to MALDI-TOF species identification, we propose a culture-free workflow, enabling bacterial identification and quantification in less than 4 h using 1 ml of urine. After rapid and automatable sample preparation, a signature of 82 bacterial peptides, defined by machine learning, was monitored in LC-MS, to distinguish the 15 species causing 84% of the UTIs. The combination of the sensitivity of the SRM mode on a triple quadrupole TSQ Altis instrument and the robustness of capillary flow enabled us to analyze up to 75 samples per day, with 99.2% accuracy on bacterial inoculations of healthy urines. We have also shown our method can be used to quantify the spread of the infection, from 8 × 104 to 3 × 107 CFU/ml. Finally, the workflow was validated on 45 inoculated urines and on 84 UTI-positive urine from patients, with respectively 93.3% and 87.1% of agreement with the culture-MALDI procedure at a level above 1 × 105 CFU/ml corresponding to an infection requiring antibiotherapy.
Collapse
Affiliation(s)
- Clarisse Gotti
- Computational Biology Laboratory, CHU de Québec - Université Laval Research Center, Québec City, Quebec, Canada; Proteomics Platform, CHU de Québec - Université Laval Research Center, Québec City, Quebec, Canada
| | - Florence Roux-Dalvai
- Computational Biology Laboratory, CHU de Québec - Université Laval Research Center, Québec City, Quebec, Canada; Proteomics Platform, CHU de Québec - Université Laval Research Center, Québec City, Quebec, Canada
| | - Ève Bérubé
- Centre de Recherche en Infectiologie de l'Université Laval, Axe Maladies Infectieuses et Immunitaires, Centre de Recherche du CHU de Québec-Université Laval, Québec City, Quebec, Canada
| | - Antoine Lacombe-Rastoll
- Computational Biology Laboratory, CHU de Québec - Université Laval Research Center, Québec City, Quebec, Canada; Proteomics Platform, CHU de Québec - Université Laval Research Center, Québec City, Quebec, Canada
| | - Mickaël Leclercq
- Computational Biology Laboratory, CHU de Québec - Université Laval Research Center, Québec City, Quebec, Canada
| | | | - Maurice Boissinot
- Centre de Recherche en Infectiologie de l'Université Laval, Axe Maladies Infectieuses et Immunitaires, Centre de Recherche du CHU de Québec-Université Laval, Québec City, Quebec, Canada
| | | | | | - Michel G Bergeron
- Centre de Recherche en Infectiologie de l'Université Laval, Axe Maladies Infectieuses et Immunitaires, Centre de Recherche du CHU de Québec-Université Laval, Québec City, Quebec, Canada
| | - Arnaud Droit
- Computational Biology Laboratory, CHU de Québec - Université Laval Research Center, Québec City, Quebec, Canada; Proteomics Platform, CHU de Québec - Université Laval Research Center, Québec City, Quebec, Canada.
| |
Collapse
|
6
|
Steel R, Timms M, Bamford N, Spence R, Sillence M. The detection of ACTH and insulin in equine plasma by solid-phase extraction and micro-flow LC/MSMS. Drug Test Anal 2024. [PMID: 38978168 DOI: 10.1002/dta.3762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 06/17/2024] [Accepted: 06/20/2024] [Indexed: 07/10/2024]
Abstract
Previous liquid chromatography/mass spectrometry (LC/MS) methods for the detection of insulin and other similar peptide hormones in equine plasma relied on the use of antibody affinity extraction. As a result, these methods were not suitable for routine high-throughput analysis. A solid-phase extraction (SPE) method incorporating size exclusion as well as reversed-phase interactions allows the selective extraction of peptide hormones such as adrenocorticotropic hormone (ACTH), insulin and their synthetic analogues from equine plasma with approximately 80% extraction efficiencies. This extraction was combined with on-column derivatisation with acetic anhydride, followed by tryptic digestion and analysis by micro-LC/MSMS for high-sensitivity peptide hormone detection. The analysis of tryptic peptides provides greater sensitivity and more robust chromatography compared with the analysis of intact insulin and ACTH. For quantitative analysis, isotopically labelled internal standards of target peptides can be prepared in the laboratory through the use of deuterated acetic anhydride. The utility of the method was assessed for the analysis of ACTH and insulin in samples from horses suffering from pituitary pars intermedia dysfunction (PPID).
Collapse
Affiliation(s)
- Rohan Steel
- Biological Research Unit, Racing Analytical Services Ltd, Flemington, Australia
| | - Mark Timms
- Biological Research Unit, Racing Analytical Services Ltd, Flemington, Australia
| | - Nicholas Bamford
- Veterinary Biosciences, Melbourne University, Parkville, Australia
| | - Robert Spence
- Department of Biological and Environmental Sciences, Queensland University of Technology, Brisbane, Australia
| | - Martin Sillence
- Department of Biological and Environmental Sciences, Queensland University of Technology, Brisbane, Australia
| |
Collapse
|
7
|
Humphries EM, Xavier D, Ashman K, Hains PG, Robinson PJ. High-Throughput Proteomics and Phosphoproteomics of Rat Tissues Using Microflow Zeno SWATH. J Proteome Res 2024; 23:2355-2366. [PMID: 38819404 DOI: 10.1021/acs.jproteome.4c00010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2024]
Abstract
High-throughput tissue proteomics has great potential in the advancement of precision medicine. Here, we investigated the combined sensitivity of trap-elute microflow liquid chromatography with a ZenoTOF for DIA proteomics and phosphoproteomics. Method optimization was conducted on HEK293T cell lines to determine the optimal variable window size, MS2 accumulation time and gradient length. The ZenoTOF 7600 was then compared to the previous generation TripleTOF 6600 using eight rat organs, finding up to 23% more proteins using a fifth of the sample load and a third of the instrument time. Spectral reference libraries generated from Zeno SWATH data in FragPipe (MSFragger-DIA/DIA-NN) contained 4 times more fragment ions than the DIA-NN only library and quantified more proteins. Replicate single-shot phosphopeptide enrichments of 50-100 μg of rat tryptic peptide were analyzed by microflow HPLC using Zeno SWATH without fractionation. Using Spectronaut we quantified a shallow phosphoproteome containing 1000-3000 phosphoprecursors per organ. Promisingly, clear hierarchical clustering of organs was observed with high Pearson correlation coefficients >0.95 between replicate enrichments and median CV of 20%. The combined sensitivity of microflow HPLC with Zeno SWATH allows for the high-throughput quantitation of an extensive proteome and shallow phosphoproteome from small tissue samples.
Collapse
Affiliation(s)
- Erin M Humphries
- ProCan®, Children's Medical Research Institute, Faculty of Medicine and Health, The University of Sydney, Westmead, New South Wales 2145, Australia
| | - Dylan Xavier
- ProCan®, Children's Medical Research Institute, Faculty of Medicine and Health, The University of Sydney, Westmead, New South Wales 2145, Australia
| | - Keith Ashman
- Sciex, 96 Ricketts Road,Mount Waverley, Victoria 3149, Australia
| | - Peter G Hains
- ProCan®, Children's Medical Research Institute, Faculty of Medicine and Health, The University of Sydney, Westmead, New South Wales 2145, Australia
| | - Phillip J Robinson
- ProCan®, Children's Medical Research Institute, Faculty of Medicine and Health, The University of Sydney, Westmead, New South Wales 2145, Australia
| |
Collapse
|
8
|
Girel S, Meister I, Glauser G, Rudaz S. Hyphenation of microflow chromatography with electrospray ionization mass spectrometry for bioanalytical applications focusing on low molecular weight compounds: A tutorial review. MASS SPECTROMETRY REVIEWS 2024. [PMID: 38952056 DOI: 10.1002/mas.21898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 06/10/2024] [Accepted: 06/20/2024] [Indexed: 07/03/2024]
Abstract
Benefits of miniaturized chromatography with various detection modes, such as increased sensitivity, chromatographic efficiency, and speed, were recognized nearly 50 years ago. Over the past two decades, this approach has experienced rapid growth, driven by the emergence of mass spectrometry applications serving -omics sciences and the need for analyzing minute volumes of precious samples with ever higher sensitivity. While nanoscale liquid chromatography (flow rates <1 μL/min) has gained widespread recognition in proteomics, the adoption of microscale setups (flow rates ranging from 1 to 100 μL/min) for low molecular weight compound applications, including metabolomics, has been surprisingly slow, despite the inherent advantages of the approach. Highly heterogeneous matrices and chemical structures accompanied by a relative lack of options for both selective sample preparation and user-friendly equipment are usually reported as major hindrances. To facilitate the wider implementation of microscale analyses, we present here a comprehensive tutorial encompassing important theoretical and practical considerations. We provide fundamental principles in micro-chromatography and guide the reader through the main elements of a microflow workflow, from LC pumps to ionization devices. Finally, based on both our literature overview and experience, illustrated by some in-house data, we highlight the critical importance of the ionization source design and its careful optimization to achieve significant sensitivity improvement.
Collapse
Affiliation(s)
- Sergey Girel
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
| | - Isabel Meister
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
- Swiss Center of Applied Human Toxicology (SCAHT), Basel, Switzerland
| | - Gaetan Glauser
- Neuchâtel Platform of Analytical Chemistry, University of Neuchâtel, Neuchâtel, Switzerland
| | - Serge Rudaz
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
- Swiss Center of Applied Human Toxicology (SCAHT), Basel, Switzerland
| |
Collapse
|
9
|
Peters-Clarke TM, Coon JJ, Riley NM. Instrumentation at the Leading Edge of Proteomics. Anal Chem 2024; 96:7976-8010. [PMID: 38738990 DOI: 10.1021/acs.analchem.3c04497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2024]
Affiliation(s)
- Trenton M Peters-Clarke
- Department of Chemistry, University of Wisconsin─Madison, Madison, Wisconsin 53706, United States
- Department of Biomolecular Chemistry, University of Wisconsin─Madison, Madison, Wisconsin 53706, United States
| | - Joshua J Coon
- Department of Chemistry, University of Wisconsin─Madison, Madison, Wisconsin 53706, United States
- Department of Biomolecular Chemistry, University of Wisconsin─Madison, Madison, Wisconsin 53706, United States
- Morgridge Institute for Research, Madison, Wisconsin 53715, United States
| | - Nicholas M Riley
- Department of Chemistry, University of Washington, Seattle, Washington 98195, United States
| |
Collapse
|
10
|
You Y, Chen X, Huo L, Chen L, Chen G, Gu M, Yi C, Wang J, Hu W. An improved medium for in vitro studies of female reproduction and oviposition in Schistosoma japonicum. Parasit Vectors 2024; 17:116. [PMID: 38454463 PMCID: PMC10918852 DOI: 10.1186/s13071-024-06191-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Accepted: 02/11/2024] [Indexed: 03/09/2024] Open
Abstract
BACKGROUND Schistosomiasis is a disease primarily caused by eggs laid by pathogens called schistosomes. Among the schistosome species infecting humans, Schistosoma japonicum possesses the largest fecundity; each adult female produces an average of 3500 eggs per day. The lack of proper culture conditions supporting continuous oviposition in vitro has precluded detailed investigation of mechanisms regulating sexual maturation and egg production in Schistosoma japonicum. METHODS We optimized in vitro culture conditions by replacing reagents that are part of the classical ABC169 medium. Fast Blue BB staining and 4',6-diamidino-2-phenylindole (DAPI) labeling were applied to observe the sexual development status of the females. In vitro RNA interference (RNAi) technology was used to validate the capability of the modified medium. The detection of male β-alanyl-tryptamine (BATT) was conducted using liquid chromatography-mass spectrometry (LC-MS). RESULTS Both m-AB169 (1640) and AB169 (1640) media are capable of facilitating the sexual development of paired virgin female S. japonicum, as well as sustaining the mature reproductive organs and egg production of adult S. japonicum for at least 22 days in vitro. M-AB169 (1640) provided a more stable condition for supporting the sexual maturity of female S. japonicum, as evidenced by the consistent initiation of egg production compared with AB169 (1640). Through a comparative analysis of S. japonicum and S. mansoni in diverse media, we demonstrated that these closely related species display distinct demands for their sexual development and egg production, suggesting a potential influence of nutritional factors on the observed variations in host ranges among different schistosome species. Importantly, we successfully identified the presence of the pheromone β-alanyl-tryptamine (BATT) in S. japonicum, previously identified in S. mansoni, highlighting its conserved role in schistosome reproductive development. Through the employment of double-stranded RNA (dsRNA) treatment to silence two genes that are involved in either the male (gli1, glioma-associated oncogene homolog 1) or female (vf1, vitellogenic factor 1) side in male-induced female reproductive development of S. mansoni, we confirmed that the combination of m-AB169 (1640) and RNAi technology has the capacity to facilitate in vitro studies of S. japonicum's reproductive and oviposition processes. CONCLUSIONS We developed a novel medium, m-AB169 (1640), that not only maintains the mature reproductive organs and continuous oviposition of adult female Schistosoma japonicum for up to 22 days but also supports the reproductive development and subsequent egg-laying of virgin females after pairing with male worms. This study provides a valuable in vitro platform for functional studies of the mechanisms underlying the fascinating biology of the female sexual development and egg production of S. japonicum, which may accelerate the development of new strategies targeting schistosome egg production.
Collapse
Affiliation(s)
- Yanmin You
- State Key Laboratory of Genetic Engineering, Ministry of Education Key Laboratory of Contemporary Anthropology, School of Life Sciences, Fudan University, Shanghai, China
| | - Xu Chen
- State Key Laboratory of Genetic Engineering, Ministry of Education Key Laboratory of Contemporary Anthropology, School of Life Sciences, Fudan University, Shanghai, China
| | - Lele Huo
- National Institute of Parasitic Diseases, Chinese Center for Disease Control and Prevention (Chinese Center for Tropical Diseases Research), NHC Key Laboratory of Parasite and Vector Biology, WHO Collaborating Center for Tropical Diseases, National Center for International Research On Tropical Diseases, Shanghai, China
| | - Longlong Chen
- Metabonomics and Systems Biology Laboratory at Shanghai International Centre for Molecular Phenomics, Fudan University, Shanghai, China
| | - Gongwen Chen
- State Key Laboratory of Genetic Engineering, Ministry of Education Key Laboratory of Contemporary Anthropology, School of Life Sciences, Fudan University, Shanghai, China
| | - Mengjie Gu
- State Key Laboratory of Genetic Engineering, Ministry of Education Key Laboratory of Contemporary Anthropology, School of Life Sciences, Fudan University, Shanghai, China
| | - Cun Yi
- State Key Laboratory of Genetic Engineering, Ministry of Education Key Laboratory of Contemporary Anthropology, School of Life Sciences, Fudan University, Shanghai, China
| | - Jipeng Wang
- State Key Laboratory of Genetic Engineering, Ministry of Education Key Laboratory of Contemporary Anthropology, School of Life Sciences, Fudan University, Shanghai, China.
| | - Wei Hu
- State Key Laboratory of Genetic Engineering, Ministry of Education Key Laboratory of Contemporary Anthropology, School of Life Sciences, Fudan University, Shanghai, China.
- National Institute of Parasitic Diseases, Chinese Center for Disease Control and Prevention (Chinese Center for Tropical Diseases Research), NHC Key Laboratory of Parasite and Vector Biology, WHO Collaborating Center for Tropical Diseases, National Center for International Research On Tropical Diseases, Shanghai, China.
| |
Collapse
|
11
|
Weigert Muñoz A, Zhao W, Sieber SA. Monitoring host-pathogen interactions using chemical proteomics. RSC Chem Biol 2024; 5:73-89. [PMID: 38333198 PMCID: PMC10849124 DOI: 10.1039/d3cb00135k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 11/09/2023] [Indexed: 02/10/2024] Open
Abstract
With the rapid emergence and the dissemination of microbial resistance to conventional chemotherapy, the shortage of novel antimicrobial drugs has raised a global health threat. As molecular interactions between microbial pathogens and their mammalian hosts are crucial to establish virulence, pathogenicity, and infectivity, a detailed understanding of these interactions has the potential to reveal novel therapeutic targets and treatment strategies. Bidirectional molecular communication between microbes and eukaryotes is essential for both pathogenic and commensal organisms to colonise their host. In particular, several devastating pathogens exploit host signalling to adjust the expression of energetically costly virulent behaviours. Chemical proteomics has emerged as a powerful tool to interrogate the protein interaction partners of small molecules and has been successfully applied to advance host-pathogen communication studies. Here, we present recent significant progress made by this approach and provide a perspective for future studies.
Collapse
Affiliation(s)
- Angela Weigert Muñoz
- Center for Functional Protein Assemblies, Department of Bioscience, TUM School of Natural Sciences, Technical University of Munich Ernst-Otto-Fischer-Straße 8 D-85748 Garching Germany
| | - Weining Zhao
- College of Pharmacy, Shenzhen Technology University Shenzhen 518118 China
| | - Stephan A Sieber
- Center for Functional Protein Assemblies, Department of Bioscience, TUM School of Natural Sciences, Technical University of Munich Ernst-Otto-Fischer-Straße 8 D-85748 Garching Germany
- Helmholtz Institute for Pharmaceutical Research Saarland (HIPS) Germany
| |
Collapse
|
12
|
Schrader M. Origins, Technological Advancement, and Applications of Peptidomics. Methods Mol Biol 2024; 2758:3-47. [PMID: 38549006 DOI: 10.1007/978-1-0716-3646-6_1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/02/2024]
Abstract
Peptidomics is the comprehensive characterization of peptides from biological sources instead of heading for a few single peptides in former peptide research. Mass spectrometry allows to detect a multitude of peptides in complex mixtures and thus enables new strategies leading to peptidomics. The term was established in the year 2001, and up to now, this new field has grown to over 3000 publications. Analytical techniques originally developed for fast and comprehensive analysis of peptides in proteomics were specifically adjusted for peptidomics. Although it is thus closely linked to proteomics, there are fundamental differences with conventional bottom-up proteomics. Fundamental technological advancements of peptidomics since have occurred in mass spectrometry and data processing, including quantification, and more slightly in separation technology. Different strategies and diverse sources of peptidomes are mentioned by numerous applications, such as discovery of neuropeptides and other bioactive peptides, including the use of biochemical assays. Furthermore, food and plant peptidomics are introduced similarly. Additionally, applications with a clinical focus are included, comprising biomarker discovery as well as immunopeptidomics. This overview extensively reviews recent methods, strategies, and applications including links to all other chapters of this book.
Collapse
Affiliation(s)
- Michael Schrader
- Department of Bioengineering Sciences, Weihenstephan-Tr. University of Applied Sciences, Freising, Germany.
| |
Collapse
|
13
|
Xiang P, Liyu A, Kwon Y, Hu D, Williams SM, Veličković D, Markillie LM, Chrisler WB, Paša-Tolić L, Zhu Y. Spatial Proteomics toward Subcellular Resolution by Coupling Deep Ultraviolet Laser Ablation with Nanodroplet Sample Preparation. ACS MEASUREMENT SCIENCE AU 2023; 3:459-468. [PMID: 38145026 PMCID: PMC10740121 DOI: 10.1021/acsmeasuresciau.3c00033] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 09/17/2023] [Accepted: 09/22/2023] [Indexed: 12/26/2023]
Abstract
Multiplexed molecular profiling of tissue microenvironments, or spatial omics, can provide critical insights into cellular functions and disease pathology. The coupling of laser microdissection with mass spectrometry-based proteomics has enabled deep and unbiased mapping of >1000 proteins. However, the throughput of laser microdissection is often limited due to tedious two-step procedures, sequential laser cutting, and sample collection. The two-step procedure also hinders the further improvement of spatial resolution to <10 μm as needed for subcellular proteomics. Herein, we developed a high-throughput and high-resolution spatial proteomics platform by seamlessly coupling deep ultraviolet (DUV) laser ablation (LA) with nanoPOTS (Nanodroplet Processing in One pot for Trace Samples)-based sample preparation. We demonstrated the DUV-LA system can quickly isolate and collect tissue samples at a throughput of ∼30 spots/min and a spatial resolution down to 2 μm from a 10 μm thick human pancreas tissue section. To improve sample recovery, we developed a proximity aerosol collection approach by placing DMSO droplets close to LA spots. We demonstrated the DUV-LA-nanoPOTS platform can detect an average of 1312, 1533, and 1966 proteins from ablation spots with diameters of 7, 13, and 19 μm, respectively. In a proof-of-concept study, we isolated and profiled two distinct subcellular regions of the pancreas tissue revealed by hematoxylin and eosin (H&E) staining. Quantitative proteomics revealed proteins specifically enriched to subcellular compartments.
Collapse
Affiliation(s)
- Piliang Xiang
- Environmental
Molecular Sciences Laboratory, Pacific Northwest
National Laboratory, Richland, Washington 99354, United States
| | - Andrey Liyu
- Environmental
Molecular Sciences Laboratory, Pacific Northwest
National Laboratory, Richland, Washington 99354, United States
| | - Yumi Kwon
- Environmental
Molecular Sciences Laboratory, Pacific Northwest
National Laboratory, Richland, Washington 99354, United States
| | - Dehong Hu
- Environmental
Molecular Sciences Laboratory, Pacific Northwest
National Laboratory, Richland, Washington 99354, United States
| | - Sarah M. Williams
- Environmental
Molecular Sciences Laboratory, Pacific Northwest
National Laboratory, Richland, Washington 99354, United States
| | - Dušan Veličković
- Environmental
Molecular Sciences Laboratory, Pacific Northwest
National Laboratory, Richland, Washington 99354, United States
| | - Lye Meng Markillie
- Environmental
Molecular Sciences Laboratory, Pacific Northwest
National Laboratory, Richland, Washington 99354, United States
| | - William B. Chrisler
- Biological
Sciences Division, Pacific Northwest National
Laboratory, Richland, Washington 99354, United States
| | - Ljiljana Paša-Tolić
- Environmental
Molecular Sciences Laboratory, Pacific Northwest
National Laboratory, Richland, Washington 99354, United States
| | - Ying Zhu
- Department
of Microchemistry, Proteomics, Lipidomics and Next Generation Sequencing, Genentech, 1 DNA Way, South San Francisco, California 94080, United States
| |
Collapse
|
14
|
Jadeja S, Kupcik R, Fabrik I, Sklenářová H, Lenčo J. A stationary phase with a positively charged surface allows for minimizing formic acid concentration in the mobile phase, enhancing electrospray ionization in LC-MS proteomic experiments. Analyst 2023; 148:5980-5990. [PMID: 37870390 DOI: 10.1039/d3an01508d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2023]
Abstract
The default choice of mobile phase acidifier for bottom-up LC-MS proteomic analyses is 0.10% formic acid because of its decent acidity, decent ion pairing ability, and low suppression of electrospray ionization. In recent years, state-of-the-art columns have been designed specifically to provide efficient separation even when using an MS-friendly mobile phase of low ionic strength. Despite this, no attempts have been made to improve the sensitivity of the MS-based analytical methods by reducing the amount of formic acid in the mobile phase. In this study, we evaluated the effect of reduced formic acid concentration in the mobile phase on the chromatographic behavior and MS response of peptides when separated using columns packed with a C18 stationary phase with a positively charged surface. Using 0.01% formic acid in the mobile phase maintained excellent chromatographic performance and increased MS signal response compared to the standard of 0.10%. The enhanced MS response translated to about 50% improved peptide identifications depending on the complexity and amount of sample injected. The increased retention of peptides at a reduced formic acid concentration was directly proportional to the number of acidic residues in the peptide sequence. The study was carried out by covering a spectrum of protein samples with varied complexity using analytical flow, micro-, and nanoflow regimes to expand the applicability in routine practice.
Collapse
Affiliation(s)
- Siddharth Jadeja
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 03 Hradec Králové, Czech Republic.
| | - Rudolf Kupcik
- Biomedical Research Centre, University Hospital Hradec Králové, Sokolská 581, 500 05 Hradec Králové, Czech Republic
| | - Ivo Fabrik
- Biomedical Research Centre, University Hospital Hradec Králové, Sokolská 581, 500 05 Hradec Králové, Czech Republic
| | - Hana Sklenářová
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 03 Hradec Králové, Czech Republic.
| | - Juraj Lenčo
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 03 Hradec Králové, Czech Republic.
| |
Collapse
|
15
|
Zhang H, Yang Y, Jiang Y, Zhang M, Xu Z, Wang X, Jiang J. Mass Spectrometry Analysis for Clinical Applications: A Review. Crit Rev Anal Chem 2023; 55:213-232. [PMID: 37910438 DOI: 10.1080/10408347.2023.2274039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2023]
Abstract
Mass spectrometry (MS) has become an attractive analytical method in clinical analysis due to its comprehensive advantages of high sensitivity, high specificity and high throughput. Separation techniques coupled MS detection (e.g., LC-MS/MS) have shown unique advantages over immunoassay and have developed as golden criterion for many clinical applications. This review summarizes the characteristics and applications of MS, and emphasizes the high efficiency of MS in clinical research. In addition, this review also put forward further prospects for the future of mass spectrometry technology, including the introduction of miniature MS instruments, point-of-care detection and high-throughput analysis, to achieve better development of MS technology in various fields of clinical application. Moreover, as ambient ionization mass spectrometry (AIMS) requires little or no sample pretreatment and improves the flux of MS, this review also summarizes its potential applications in clinic.
Collapse
Affiliation(s)
- Hong Zhang
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, P. R. China
| | - Yali Yang
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, P. R. China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, P. R. China
| | - Yanxiao Jiang
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, P. R. China
| | - Meng Zhang
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, P. R. China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, P. R. China
| | - Zhilong Xu
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, P. R. China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, P. R. China
| | - Xiaofei Wang
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, P. R. China
| | - Jie Jiang
- School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, P. R. China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, P. R. China
| |
Collapse
|
16
|
Phipps WS, Kilgore MR, Kennedy JJ, Whiteaker JR, Hoofnagle AN, Paulovich AG. Clinical Proteomics for Solid Organ Tissues. Mol Cell Proteomics 2023; 22:100648. [PMID: 37730181 PMCID: PMC10692389 DOI: 10.1016/j.mcpro.2023.100648] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 09/07/2023] [Accepted: 09/12/2023] [Indexed: 09/22/2023] Open
Abstract
The evaluation of biopsied solid organ tissue has long relied on visual examination using a microscope. Immunohistochemistry is critical in this process, labeling and detecting cell lineage markers and therapeutic targets. However, while the practice of immunohistochemistry has reshaped diagnostic pathology and facilitated improvements in cancer treatment, it has also been subject to pervasive challenges with respect to standardization and reproducibility. Efforts are ongoing to improve immunohistochemistry, but for some applications, the benefit of such initiatives could be impeded by its reliance on monospecific antibody-protein reagents and limited multiplexing capacity. This perspective surveys the relevant challenges facing traditional immunohistochemistry and describes how mass spectrometry, particularly liquid chromatography-tandem mass spectrometry, could help alleviate problems. In particular, targeted mass spectrometry assays could facilitate measurements of individual proteins or analyte panels, using internal standards for more robust quantification and improved interlaboratory reproducibility. Meanwhile, untargeted mass spectrometry, showcased to date clinically in the form of amyloid typing, is inherently multiplexed, facilitating the detection and crude quantification of 100s to 1000s of proteins in a single analysis. Further, data-independent acquisition has yet to be applied in clinical practice, but offers particular strengths that could appeal to clinical users. Finally, we discuss the guidance that is needed to facilitate broader utilization in clinical environments and achieve standardization.
Collapse
Affiliation(s)
- William S Phipps
- Department of Laboratory Medicine and Pathology, University of Washington School of Medicine, Seattle, Washington, USA
| | - Mark R Kilgore
- Department of Laboratory Medicine and Pathology, University of Washington School of Medicine, Seattle, Washington, USA
| | - Jacob J Kennedy
- Clinical Research Division, Fred Hutchinson Cancer Research Center, Seattle, Washington, USA
| | - Jeffrey R Whiteaker
- Clinical Research Division, Fred Hutchinson Cancer Research Center, Seattle, Washington, USA
| | - Andrew N Hoofnagle
- Department of Laboratory Medicine and Pathology, University of Washington School of Medicine, Seattle, Washington, USA; Department of Medicine, University of Washington School of Medicine, Seattle, Washington, USA.
| | - Amanda G Paulovich
- Clinical Research Division, Fred Hutchinson Cancer Research Center, Seattle, Washington, USA; Department of Medicine, University of Washington School of Medicine, Seattle, Washington, USA.
| |
Collapse
|
17
|
Saunders KD, von Gerichten J, Lewis HM, Gupta P, Spick M, Costa C, Velliou E, Bailey MJ. Single-Cell Lipidomics Using Analytical Flow LC-MS Characterizes the Response to Chemotherapy in Cultured Pancreatic Cancer Cells. Anal Chem 2023; 95:14727-14735. [PMID: 37725657 PMCID: PMC10551860 DOI: 10.1021/acs.analchem.3c02854] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Accepted: 09/07/2023] [Indexed: 09/21/2023]
Abstract
In this work, we demonstrate the development and first application of nanocapillary sampling followed by analytical flow liquid chromatography-mass spectrometry for single-cell lipidomics. Around 260 lipids were tentatively identified in a single cell, demonstrating remarkable sensitivity. Human pancreatic ductal adenocarcinoma cells (PANC-1) treated with the chemotherapeutic drug gemcitabine can be distinguished from controls solely on the basis of their single-cell lipid profiles. Notably, the relative abundance of LPC(0:0/16:0) was significantly affected in gemcitabine-treated cells, in agreement with previous work in bulk. This work serves as a proof of concept that live cells can be sampled selectively and then characterized using automated and widely available analytical workflows, providing biologically relevant outputs.
Collapse
Affiliation(s)
| | | | - Holly-May Lewis
- Faculty
of Health & Medical Sciences, University
of Surrey, Guildford GU2 7XH, U.K.
| | - Priyanka Gupta
- Centre
for 3D Models of Health and Disease, University
College London—Division of Surgery and Interventional Science, London W1W 7TY, U.K.
| | - Matt Spick
- Faculty
of Health & Medical Sciences, University
of Surrey, Guildford GU2 7XH, U.K.
| | - Catia Costa
- Ion
Beam Centre, University of Surrey, Guildford GU2 7XH, U.K.
| | - Eirini Velliou
- Centre
for 3D Models of Health and Disease, University
College London—Division of Surgery and Interventional Science, London W1W 7TY, U.K.
| | - Melanie J. Bailey
- Department
of Chemistry, University of Surrey, Guildford GU2 7XH, U.K.
| |
Collapse
|
18
|
Teunissen CE, Kimble L, Bayoumy S, Bolsewig K, Burtscher F, Coppens S, Das S, Gogishvili D, Fernandes Gomes B, Gómez de San José N, Mavrina E, Meda FJ, Mohaupt P, Mravinacová S, Waury K, Wojdała AL, Abeln S, Chiasserini D, Hirtz C, Gaetani L, Vermunt L, Bellomo G, Halbgebauer S, Lehmann S, Månberg A, Nilsson P, Otto M, Vanmechelen E, Verberk IMW, Willemse E, Zetterberg H. Methods to Discover and Validate Biofluid-Based Biomarkers in Neurodegenerative Dementias. Mol Cell Proteomics 2023; 22:100629. [PMID: 37557955 PMCID: PMC10594029 DOI: 10.1016/j.mcpro.2023.100629] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 07/24/2023] [Accepted: 07/31/2023] [Indexed: 08/11/2023] Open
Abstract
Neurodegenerative dementias are progressive diseases that cause neuronal network breakdown in different brain regions often because of accumulation of misfolded proteins in the brain extracellular matrix, such as amyloids or inside neurons or other cell types of the brain. Several diagnostic protein biomarkers in body fluids are being used and implemented, such as for Alzheimer's disease. However, there is still a lack of biomarkers for co-pathologies and other causes of dementia. Such biofluid-based biomarkers enable precision medicine approaches for diagnosis and treatment, allow to learn more about underlying disease processes, and facilitate the development of patient inclusion and evaluation tools in clinical trials. When designing studies to discover novel biofluid-based biomarkers, choice of technology is an important starting point. But there are so many technologies to choose among. To address this, we here review the technologies that are currently available in research settings and, in some cases, in clinical laboratory practice. This presents a form of lexicon on each technology addressing its use in research and clinics, its strengths and limitations, and a future perspective.
Collapse
Affiliation(s)
- Charlotte E Teunissen
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Neurochemistry Lab, Department of Laboratory Medicine, Amsterdam Neuroscience, Amsterdam UMC, Vrije Universiteit, Amsterdam, Netherlands.
| | - Leighann Kimble
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; KIN Center for Digital Innovation, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| | - Sherif Bayoumy
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Neurochemistry Lab, Department of Laboratory Medicine, Amsterdam Neuroscience, Amsterdam UMC, Vrije Universiteit, Amsterdam, Netherlands
| | - Katharina Bolsewig
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Neurochemistry Lab, Department of Laboratory Medicine, Amsterdam Neuroscience, Amsterdam UMC, Vrije Universiteit, Amsterdam, Netherlands
| | - Felicia Burtscher
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Luxembourg Centre for Systems Biomedicine, University of Luxembourg, Esch-sur-Alzette, Luxembourg
| | - Salomé Coppens
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; National Measurement Laboratory at LGC, Teddington, United Kingdom
| | - Shreyasee Das
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; ADx NeuroSciences, Gent, Belgium
| | - Dea Gogishvili
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Department of Computer Science, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| | - Bárbara Fernandes Gomes
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Department of Psychiatry and Neurochemistry, Institute of Neuroscience and Physiology, The Sahlgrenska Academy at the University of Gothenburg, Mölndal, Sweden
| | - Nerea Gómez de San José
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Department of Neurology, University of Ulm, Ulm, Germany
| | - Ekaterina Mavrina
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; KIN Center for Digital Innovation, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| | - Francisco J Meda
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Department of Psychiatry and Neurochemistry, Institute of Neuroscience and Physiology, The Sahlgrenska Academy at the University of Gothenburg, Mölndal, Sweden
| | - Pablo Mohaupt
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; LBPC-PPC, IRMB CHU Montpellier, INM INSERM, Université de Montpellier, Montpellier, France
| | - Sára Mravinacová
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Division of Affinity Proteomics, Department of Protein Science, KTH Royal Institute of Technology, SciLifeLab, Stockholm, Sweden
| | - Katharina Waury
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Department of Computer Science, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| | - Anna Lidia Wojdała
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Section of Neurology, Department of Medicine and Surgery, University of Perugia, Perugia, Italy
| | - Sanne Abeln
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Department of Computer Science, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| | - Davide Chiasserini
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Section of Physiology and Biochemistry, Department of Medicine and Surgery, University of Perugia, Perugia, Italy
| | - Christophe Hirtz
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; LBPC-PPC, IRMB CHU Montpellier, INM INSERM, Université de Montpellier, Montpellier, France
| | - Lorenzo Gaetani
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Section of Neurology, Department of Medicine and Surgery, University of Perugia, Perugia, Italy
| | - Lisa Vermunt
- Neurochemistry Lab, Department of Laboratory Medicine, Amsterdam Neuroscience, Amsterdam UMC, Vrije Universiteit, Amsterdam, Netherlands
| | - Giovanni Bellomo
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Section of Neurology, Department of Medicine and Surgery, University of Perugia, Perugia, Italy
| | - Steffen Halbgebauer
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Department of Neurology, University of Ulm, Ulm, Germany; German Center for Neurodegenerative Diseases (DZNE e.V.), Ulm, Germany
| | - Sylvain Lehmann
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; LBPC-PPC, IRMB CHU Montpellier, INM INSERM, Université de Montpellier, Montpellier, France
| | - Anna Månberg
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Division of Affinity Proteomics, Department of Protein Science, KTH Royal Institute of Technology, SciLifeLab, Stockholm, Sweden
| | - Peter Nilsson
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Division of Affinity Proteomics, Department of Protein Science, KTH Royal Institute of Technology, SciLifeLab, Stockholm, Sweden
| | - Markus Otto
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Department of Neurology, University of Ulm, Ulm, Germany; Department of Neurology, Martin-Luther-University Halle-Wittenberg, Halle, Germany
| | - Eugeen Vanmechelen
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; ADx NeuroSciences, Gent, Belgium
| | - Inge M W Verberk
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Neurochemistry Lab, Department of Laboratory Medicine, Amsterdam Neuroscience, Amsterdam UMC, Vrije Universiteit, Amsterdam, Netherlands
| | - Eline Willemse
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Neurochemistry Lab, Department of Laboratory Medicine, Amsterdam Neuroscience, Amsterdam UMC, Vrije Universiteit, Amsterdam, Netherlands
| | - Henrik Zetterberg
- MIRIADE Consortium, Multiomics Interdisciplinary Research Integration to Address DEmentia diagnosis, Amsterdam, The Netherlands; Department of Psychiatry and Neurochemistry, Institute of Neuroscience and Physiology, The Sahlgrenska Academy at the University of Gothenburg, Mölndal, Sweden; Clinical Neurochemistry Laboratory, Sahlgrenska University Hospital, Mölndal, Sweden; Department of Neurodegenerative Disease, UCL Institute of Neurology, London, UK; UK Dementia Research Institute at UCL, London, UK; Hong Kong Center for Neurodegenerative Diseases, Clear Water Bay, Hong Kong, China; Wisconsin Alzheimer's Disease Research Center, University of Wisconsin School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
19
|
Mendonça APS, Dos Reis KL, Barbosa-Tessmann IP. Aspergillus clavatus UEM 04: An efficient producer of glucoamylase and α-amylase able to hydrolyze gelatinized and raw starch. Int J Biol Macromol 2023; 249:125890. [PMID: 37479205 DOI: 10.1016/j.ijbiomac.2023.125890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2023] [Revised: 06/04/2023] [Accepted: 07/17/2023] [Indexed: 07/23/2023]
Abstract
The best amylolytic activity production by Aspergillus clavatus UEM 04 occurred in submersed culture, with starch, for 72 h, at 25 °C, and 100 rpm. Exclusion chromatography partially purified two enzymes, which ran as unique bands in SDS-PAGE with approximately 84 kDa. LC-MS/MS identified a glucoamylase (GH15) and an α-amylase (GH13_1) as the predominant proteins and other co-purified proteins. Zn2+, Cu2+, and Mn2+ activated the glucoamylase, and SDS, Zn2+, Fe3+, and Cu2+ inhibited the α-amylase. The α-amylase optimum pH was 6.5. The optimal temperatures for the glucoamylase and α-amylase were 50 °C and 40 °C, and the Tm was 53.1 °C and 56.3 °C, respectively. Both enzymes remained almost fully active for 28-32 h at 40 °C, but the α-amylase thermal stability was calcium-dependent. Furthermore, the glucoamylase and α-amylase KM for starch were 2.95 and 1.0 mg/mL, respectively. Still, the Vmax was 0.28 μmol/min of released glucose for glucoamylase and 0.1 mg/min of consumed starch for α-amylase. Moreover, the glucoamylase showed greater affinity for amylopectin and α-amylase for maltodextrin. Additionally, both enzymes efficiently degraded raw starch. At last, glucose was the main product of glucoamylase, and α-amylase produced mainly maltose from gelatinized soluble starch hydrolysis.
Collapse
Affiliation(s)
- Ana Paula Silva Mendonça
- Biological Sciences Center, Department of Biochemistry, Universidade Estadual de Maringá, Maringá, PR, Brazil
| | - Karina Lima Dos Reis
- Biological Sciences Center, Department of Biochemistry, Universidade Estadual de Maringá, Maringá, PR, Brazil
| | - Ione Parra Barbosa-Tessmann
- Biological Sciences Center, Department of Biochemistry, Universidade Estadual de Maringá, Maringá, PR, Brazil.
| |
Collapse
|
20
|
Luo Y, Huang Y, Deng L, Li Z, Li C. Metabolomic Profiling of Female Mink Serum during Early to Mid-Pregnancy to Reveal Metabolite Changes. Genes (Basel) 2023; 14:1759. [PMID: 37761899 PMCID: PMC10531253 DOI: 10.3390/genes14091759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 08/29/2023] [Accepted: 08/29/2023] [Indexed: 09/29/2023] Open
Abstract
Mink embryos enter a period of diapause after the embryo develops into the blastocyst, and its reactivation is mainly caused by an increase in polyamine. The specific process of embryo diapause regulation and reactivation remains largely unexamined. This study aimed to identify changes in metabolites in the early pregnancy of mink by comparing and analyzing in serum metabolites up to twenty-nine days after mating. Blood samples were taken on the first day of mating, once a week until the fifth week. Metabolomic profiles of the serum samples taken during this period were analyzed by ultra-performance liquid chromatography/mass spectrometry. Multivariate statistical analyses identified differential metabolite expression at different time points in both positive and negative ion modes. The levels of dopamine, tyramine, L-phenylalanine, L-tyrosine, tyrosine, L-kynurenine, L-lysine, L-arginine, D-ornithine, and leucine changed significantly. These metabolites may be associated with the process of embryo diapause and subsequent reactivation.
Collapse
Affiliation(s)
| | | | | | | | - Chunjin Li
- College of Animal Science, Jilin University, Changchun 130062, China; (Y.L.); (Y.H.); (L.D.); (Z.L.)
| |
Collapse
|
21
|
Midha MK, Kapil C, Maes M, Baxter DH, Morrone SR, Prokop TJ, Moritz RL. Vacuum Insulated Probe Heated Electrospray Ionization Source Enhances Microflow Rate Chromatography Signals in the Bruker timsTOF Mass Spectrometer. J Proteome Res 2023; 22:2525-2537. [PMID: 37294184 PMCID: PMC11060334 DOI: 10.1021/acs.jproteome.3c00305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
By far the largest contribution to ion detectability in liquid chromatography-driven mass spectrometry-based proteomics is the efficient generation of peptide molecular ions by the electrospray source. To maximize the transfer of peptides from the liquid to gaseous phase and allow molecular ions to enter the mass spectrometer at microspray flow rates, an efficient electrospray process is required. Here we describe the superior performance of newly design vacuum insulated probe heated electrospray ionization (VIP-HESI) source coupled to a Bruker timsTOF PRO mass spectrometer operated in microspray mode. VIP-HESI significantly improves chromatography signals in comparison to electrospray ionization (ESI) and nanospray ionization using the captivespray (CS) source and provides increased protein detection with higher quantitative precision, enhancing reproducibility of sample injection amounts. Protein quantitation of human K562 lymphoblast samples displayed excellent chromatographic retention time reproducibility (<10% coefficient of variation (CV)) with no signal degradation over extended periods of time, and a mouse plasma proteome analysis identified 12% more plasma protein groups allowing large-scale analysis to proceed with confidence (1,267 proteins at 0.4% CV). We show that the Slice-PASEF VIP-HESI mode is sensitive in identifying low amounts of peptide without losing quantitative precision. We demonstrate that VIP-HESI coupled with microflow rate chromatography achieves a higher depth of coverage and run-to-run reproducibility for a broad range of proteomic applications. Data and spectral libraries are available via ProteomeXchange (PXD040497).
Collapse
Affiliation(s)
- Mukul K Midha
- Institute for Systems Biology, 401 Terry Avenue N, Seattle, Washington 98109, United States
| | - Charu Kapil
- Institute for Systems Biology, 401 Terry Avenue N, Seattle, Washington 98109, United States
| | - Michal Maes
- Institute for Systems Biology, 401 Terry Avenue N, Seattle, Washington 98109, United States
| | - David H Baxter
- Institute for Systems Biology, 401 Terry Avenue N, Seattle, Washington 98109, United States
| | - Seamus R Morrone
- Institute for Systems Biology, 401 Terry Avenue N, Seattle, Washington 98109, United States
| | - Timothy J Prokop
- Institute for Systems Biology, 401 Terry Avenue N, Seattle, Washington 98109, United States
| | - Robert L Moritz
- Institute for Systems Biology, 401 Terry Avenue N, Seattle, Washington 98109, United States
| |
Collapse
|
22
|
Singh VK, Srivastava M, Seed TM. Protein biomarkers for radiation injury and testing of medical countermeasure efficacy: promises, pitfalls, and future directions. Expert Rev Proteomics 2023; 20:221-246. [PMID: 37752078 DOI: 10.1080/14789450.2023.2263652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 09/11/2023] [Indexed: 09/28/2023]
Abstract
INTRODUCTION Radiological/nuclear accidents, hostile military activity, or terrorist strikes have the potential to expose a large number of civilians and military personnel to high doses of radiation resulting in the development of acute radiation syndrome and delayed effects of exposure. Thus, there is an urgent need for sensitive and specific assays to assess the levels of radiation exposure to individuals. Such radiation exposures are expected to alter primary cellular proteomic processes, resulting in multifaceted biological responses. AREAS COVERED This article covers the application of proteomics, a promising and fast developing technology based on quantitative and qualitative measurements of protein molecules for possible rapid measurement of radiation exposure levels. Recent advancements in high-resolution chromatography, mass spectrometry, high-throughput, and bioinformatics have resulted in comprehensive (relative quantitation) and precise (absolute quantitation) approaches for the discovery and accuracy of key protein biomarkers of radiation exposure. Such proteome biomarkers might prove useful for assessing radiation exposure levels as well as for extrapolating the pharmaceutical dose of countermeasures for humans based on efficacy data generated using animal models. EXPERT OPINION The field of proteomics promises to be a valuable asset in evaluating levels of radiation exposure and characterizing radiation injury biomarkers.
Collapse
Affiliation(s)
- Vijay K Singh
- Division of Radioprotectants, Department of Pharmacology and Molecular Therapeutics, F. Edward Hébert School of Medicine, Uniformed Services University of the Health Sciences, Bethesda, MD, USA
- Armed Forces Radiobiology Research Institute, Uniformed Services University of the Health Sciences, Bethesda, MD, USA
| | - Meera Srivastava
- Department of Anatomy, Physiology and Genetics, F. Edward Hébert School of Medicine, Uniformed Services University of the Health Sciences, Bethesda, MD, USA
| | | |
Collapse
|
23
|
Bader JM, Albrecht V, Mann M. MS-based proteomics of body fluids: The end of the beginning. Mol Cell Proteomics 2023:100577. [PMID: 37209816 PMCID: PMC10388585 DOI: 10.1016/j.mcpro.2023.100577] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 05/07/2023] [Accepted: 05/11/2023] [Indexed: 05/22/2023] Open
Abstract
Accurate biomarkers are a crucial and necessary precondition for precision medicine, yet existing ones are often unspecific and new ones have been very slow to enter the clinic. Mass spectrometry (MS)-based proteomics excels by its untargeted nature, specificity of identification and quantification making it an ideal technology for biomarker discovery and routine measurement. It has unique attributes compared to affinity binder technologies, such as OLINK Proximity Extension Assay and SOMAscan. In a previous review we described technological and conceptual limitations that had held back success (Geyer et al., 2017). We proposed a 'rectangular strategy' to better separate true biomarkers by minimizing cohort-specific effects. Today, this has converged with advances in MS-based proteomics technology, such as increased sample throughput, depth of identification and quantification. As a result, biomarker discovery studies have become more successful, producing biomarker candidates that withstand independent verification and, in some cases, already outperform state-of-the-art clinical assays. We summarize developments over the last years, including the benefits of large and independent cohorts, which are necessary for clinical acceptance. They are also required for machine learning or deep learning. Shorter gradients, new scan modes and multiplexing are about to drastically increase throughput, cross-study integration, and quantification, including proxies for absolute levels. We have found that multi-protein panels are inherently more robust than current single analyte tests and better capture the complexity of human phenotypes. Routine MS measurement in the clinic is fast becoming a viable option. The full set of proteins in a body fluid (global proteome) is the most important reference and the best process control. Additionally, it increasingly has all the information that could be obtained from targeted analysis although the latter may be the most straightforward way to enter into regular use. Many challenges remain, not least of a regulatory and ethical nature, but the outlook for MS-based clinical applications has never been brighter.
Collapse
Affiliation(s)
- Jakob M Bader
- Department of Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, 82152 Martinsried, Germany
| | - Vincent Albrecht
- Department of Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, 82152 Martinsried, Germany
| | - Matthias Mann
- Department of Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, 82152 Martinsried, Germany; Novo Nordisk Foundation Center for Protein Research, Faculty of Health Sciences, University of Copenhagen, 2200 Copenhagen, Denmark.
| |
Collapse
|
24
|
Sedláčková S, Hubálek M, Vrkoslav V, Blechová M, Kozlík P, Cvačka J. Positive Effect of Acetylation on Proteomic Analysis Based on Liquid Chromatography with Atmospheric Pressure Chemical Ionization and Photoionization Mass Spectrometry. Molecules 2023; 28:molecules28093711. [PMID: 37175121 PMCID: PMC10180487 DOI: 10.3390/molecules28093711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 04/14/2023] [Accepted: 04/21/2023] [Indexed: 05/15/2023] Open
Abstract
A typical bottom-up proteomic workflow comprises sample digestion with trypsin, separation of the hydrolysate using reversed-phase HPLC, and detection of peptides via electrospray ionization (ESI) tandem mass spectrometry. Despite the advantages and wide usage of protein identification and quantification, the procedure has limitations. Some domains or parts of the proteins may remain inadequately described due to inefficient detection of certain peptides. This study presents an alternative approach based on sample acetylation and mass spectrometry with atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). These ionizations allowed for improved detection of acetylated peptides obtained via chymotrypsin or glutamyl peptidase I (Glu-C) digestion. APCI and APPI spectra of acetylated peptides often provided sequence information already at the full scan level, while fragmentation spectra of protonated molecules and sodium adducts were easy to interpret. As demonstrated for bovine serum albumin, acetylation improved proteomic analysis. Compared to ESI, gas-phase ionizations APCI and APPI made it possible to detect more peptides and provide better sequence coverages in most cases. Importantly, APCI and APPI detected many peptides which passed unnoticed in the ESI source. Therefore, analytical methods based on chymotrypsin or Glu-C digestion, acetylation, and APPI or APCI provide data complementary to classical bottom-up proteomics.
Collapse
Affiliation(s)
- Simona Sedláčková
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 16000 Prague, Czech Republic
- Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 2030/8, 12800 Prague, Czech Republic
| | - Martin Hubálek
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 16000 Prague, Czech Republic
| | - Vladimír Vrkoslav
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 16000 Prague, Czech Republic
| | - Miroslava Blechová
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 16000 Prague, Czech Republic
| | - Petr Kozlík
- Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 2030/8, 12800 Prague, Czech Republic
| | - Josef Cvačka
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 16000 Prague, Czech Republic
- Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 2030/8, 12800 Prague, Czech Republic
| |
Collapse
|
25
|
Midha MK, Kapil C, Maes M, Baxter DH, Morrone SR, Prokop TJ, Moritz RL. Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.02.15.528699. [PMID: 36824828 PMCID: PMC9949110 DOI: 10.1101/2023.02.15.528699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
Abstract
By far the largest contribution to ion detectability in liquid chromatography-driven mass spectrometry-based proteomics is the efficient generation of peptide ions by the electrospray source. To maximize the transfer of peptides from liquid to a gaseous phase to allow molecular ions to enter the mass spectrometer at micro-spray flow rates, an efficient electrospray process is required. Here we describe superior performance of new Vacuum-Insulated-Probe-Heated-ElectroSpray-Ionization source (VIP-HESI) coupled with micro-spray flow rate chromatography and Bruker timsTOF PRO mass spectrometer. VIP-HESI significantly improves chromatography signals in comparison to nano-spray ionization using the CaptiveSpray source and provides increased protein detection with higher quantitative precision, enhancing reproducibility of sample injection amounts. Protein quantitation of human K562 lymphoblast samples displayed excellent chromatographic retention time reproducibility (<10% coefficient-of-variation (CV)) with no signal degradation over extended periods of time, and a mouse plasma proteome analysis identified 12% more plasma protein groups allowing large-scale analysis to proceed with confidence (1,267 proteins at 0.4% CV). We show that Slice-PASEF mode with VIP-HESI setup is sensitive in identifying low amounts of peptide without losing quantitative precision. We demonstrate that VIP-HESI coupled with micro-flow-rate chromatography achieves higher depth of coverage and run-to-run reproducibility for a broad range of proteomic applications.
Collapse
|
26
|
Embracing lipidomics at single-cell resolution: Promises and pitfalls. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.116973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
|
27
|
Bersching K, Michna T, Tenzer S, Jacob S. Data-Independent Acquisition (DIA) Is Superior for High Precision Phospho-Peptide Quantification in Magnaporthe oryzae. J Fungi (Basel) 2022; 9:jof9010063. [PMID: 36675884 PMCID: PMC9863866 DOI: 10.3390/jof9010063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 12/16/2022] [Accepted: 12/21/2022] [Indexed: 01/04/2023] Open
Abstract
The dynamic interplay of signaling networks in most major cellular processes is characterized by the orchestration of reversible protein phosphorylation. Consequently, analytic methods such as quantitative phospho-peptidomics have been pushed forward from a highly specialized edge-technique to a powerful and versatile platform for comprehensively analyzing the phosphorylation profile of living organisms. Despite enormous progress in instrumentation and bioinformatics, a high number of missing values caused by the experimental procedure remains a major problem, due to either a random phospho-peptide enrichment selectivity or borderline signal intensities, which both cause the exclusion for fragmentation using the commonly applied data dependent acquisition (DDA) mode. Consequently, an incomplete dataset reduces confidence in the subsequent statistical bioinformatic processing. Here, we successfully applied data independent acquisition (DIA) by using the filamentous fungus Magnaporthe oryzae as a model organism, and could prove that while maintaining data quality (such as phosphosite and peptide sequence confidence), the data completeness increases dramatically. Since the method presented here reduces the LC-MS/MS analysis from 3 h to 1 h and increases the number of phosphosites identified up to 10-fold in contrast to published studies in Magnaporthe oryzae, we provide a refined methodology and a sophisticated resource for investigation of signaling processes in filamentous fungi.
Collapse
Affiliation(s)
- Katharina Bersching
- Institute of Biotechnology and Drug Research gGmbH (IBWF), Hanns-Dieter-Hüsch-Weg 17, 55131 Mainz, Germany
| | - Thomas Michna
- Institute for Immunology, University Medical Center of the Johannes Gutenberg University Mainz, 55131 Mainz, Germany
| | - Stefan Tenzer
- Institute for Immunology, University Medical Center of the Johannes Gutenberg University Mainz, 55131 Mainz, Germany
- Helmholtz-Institute for Translational Oncology Mainz (HI-TRON), 55131 Mainz, Germany
- German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
| | - Stefan Jacob
- Institute of Biotechnology and Drug Research gGmbH (IBWF), Hanns-Dieter-Hüsch-Weg 17, 55131 Mainz, Germany
- Correspondence:
| |
Collapse
|