1
|
Samal S, Nelson S, Du Z, Wang D, Wang T, Yang C, Deng Q, Parkinson EI, Mei J. Blood-Catalyzed Polymerization Creates Conductive Polymer in Live Zebrafish. RESEARCH SQUARE 2024:rs.3.rs-3602290. [PMID: 38978602 PMCID: PMC11230466 DOI: 10.21203/rs.3.rs-3602290/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/10/2024]
Abstract
Conducting polymers are of great interest in bioimaging, bio-interfaces, and bioelectronics for their biocompatibility and the unique combination of optical, electrical, and mechanical properties. They are typically prepared outside through traditional organic synthesis and delivered into the biological systems. The ability to call for the polymerization ingredients available inside the living systems to generate conducting polymers in vivo will offer new venues in future biomedical applications. This study is the first report of in vivo synthesis of an n-doped conducting polymer (n-PBDF) within live zebrafish embryos, achieved through whole blood catalyzed polymerization of 3,7-dihydrobenzo[1,2-b:4,5-b']difuran-2,6-dione (BDF). Prior to this, the efficacy of such a polymerization was rigorously established through a sequence of in vitro experiments involving Hemin, Hemoproteins (Hemoglobin, Myoglobin, and Cytochrome C), red blood cells, and the whole blood. Ultimately, in cellulo formed n-PBDF within cultured primary neurons demonstrated enhanced bio-interfaces and led to more effective light-induced neural activation than the prefabricated polymer. This underscores the potential advantages of synthesizing conducting polymers directly in living systems for biomedical applications.
Collapse
Affiliation(s)
- Sanket Samal
- Department of Chemistry, Purdue University, West Lafayette, IN, USA
| | - Samantha Nelson
- Department of Medicinal Chemistry and Molecular Pharmacology, Purdue University, West Lafayette, IN, USA
| | - Zhiyi Du
- Department of Chemistry, Boston University, Boston, MA, USA
| | - Decheng Wang
- Department of Biological Sciences, Purdue University, West Lafayette, IN, USA
| | - Tianqi Wang
- Department of Biological Sciences, Purdue University, West Lafayette, IN, USA
| | - Chen Yang
- Department of Chemistry, Boston University, Boston, MA, USA
| | - Qing Deng
- Department of Biological Sciences, Purdue University, West Lafayette, IN, USA
- Purdue Institute for Inflammation, Immunology & Infectious Diseases, Purdue University, West Lafayette, IN, USA
- Purdue University Center for Cancer Research, Purdue University, West Lafayette, IN, USA
| | - Elizabeth I. Parkinson
- Department of Chemistry, Purdue University, West Lafayette, IN, USA
- Department of Medicinal Chemistry and Molecular Pharmacology, Purdue University, West Lafayette, IN, USA
| | - Jianguo Mei
- Department of Chemistry, Purdue University, West Lafayette, IN, USA
| |
Collapse
|
2
|
Sha B, Du Z. Neural repair and regeneration interfaces: a comprehensive review. Biomed Mater 2024; 19:022002. [PMID: 38232383 DOI: 10.1088/1748-605x/ad1f78] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Accepted: 01/17/2024] [Indexed: 01/19/2024]
Abstract
Neural interfaces play a pivotal role in neuromodulation, as they enable precise intervention into aberrant neural activity and facilitate recovery from neural injuries and resultant functional impairments by modulating local immune responses and neural circuits. This review outlines the development and applications of these interfaces and highlights the advantages of employing neural interfaces for neural stimulation and repair, including accurate targeting of specific neural populations, real-time monitoring and control of neural activity, reduced invasiveness, and personalized treatment strategies. Ongoing research aims to enhance the biocompatibility, stability, and functionality of these interfaces, ultimately augmenting their therapeutic potential for various neurological disorders. The review focuses on electrophysiological and optophysiology neural interfaces, discussing functionalization and power supply approaches. By summarizing the techniques, materials, and methods employed in this field, this review aims to provide a comprehensive understanding of the potential applications and future directions for neural repair and regeneration devices.
Collapse
Affiliation(s)
- Baoning Sha
- Brain Cognition and Brain Disease Institute, CAS Key Laboratory of Brain Connectome and Manipulation, Guangdong Provincial Key Laboratory of Brain Connectome and Behavior, Shenzhen institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China
- Shenzhen-Hong Kong Institute of Brain Science, Shenzhen Fundamental Research Institutions, Shenzhen, People's Republic of China
- Department of Biomedical Engineering, Columbia University, New York, NY, United States of America
| | - Zhanhong Du
- Brain Cognition and Brain Disease Institute, CAS Key Laboratory of Brain Connectome and Manipulation, Guangdong Provincial Key Laboratory of Brain Connectome and Behavior, Shenzhen institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China
- Shenzhen-Hong Kong Institute of Brain Science, Shenzhen Fundamental Research Institutions, Shenzhen, People's Republic of China
- University of Chinese Academy of Sciences, Beijing, People's Republic of China
- Faculty of Life and Health Sciences, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China
| |
Collapse
|
3
|
Boulingre M, Portillo-Lara R, Green RA. Biohybrid neural interfaces: improving the biological integration of neural implants. Chem Commun (Camb) 2023; 59:14745-14758. [PMID: 37991846 PMCID: PMC10720954 DOI: 10.1039/d3cc05006h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 11/10/2023] [Indexed: 11/24/2023]
Abstract
Implantable neural interfaces (NIs) have emerged in the clinic as outstanding tools for the management of a variety of neurological conditions caused by trauma or disease. However, the foreign body reaction triggered upon implantation remains one of the major challenges hindering the safety and longevity of NIs. The integration of tools and principles from biomaterial design and tissue engineering has been investigated as a promising strategy to develop NIs with enhanced functionality and performance. In this Feature Article, we highlight the main bioengineering approaches for the development of biohybrid NIs with an emphasis on relevant device design criteria. Technical and scientific challenges associated with the fabrication and functional assessment of technologies composed of both artificial and biological components are discussed. Lastly, we provide future perspectives related to engineering, regulatory, and neuroethical challenges to be addressed towards the realisation of the promise of biohybrid neurotechnology.
Collapse
Affiliation(s)
- Marjolaine Boulingre
- Department of Bioengineering, Imperial College London, South Kensington, London, SW7 2AZ, UK
| | - Roberto Portillo-Lara
- Department of Bioengineering, Imperial College London, South Kensington, London, SW7 2AZ, UK
| | - Rylie A Green
- Department of Bioengineering, Imperial College London, South Kensington, London, SW7 2AZ, UK
| |
Collapse
|
4
|
Zhang A, Loh KY, Kadur CS, Michalek L, Dou J, Ramakrishnan C, Bao Z, Deisseroth K. Genetically targeted chemical assembly of polymers specifically localized extracellularly to surface membranes of living neurons. SCIENCE ADVANCES 2023; 9:eadi1870. [PMID: 37556541 PMCID: PMC10411876 DOI: 10.1126/sciadv.adi1870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2023] [Accepted: 07/05/2023] [Indexed: 08/11/2023]
Abstract
Multicellular biological systems, particularly living neural networks, exhibit highly complex organization properties that pose difficulties for building cell-specific biocompatible interfaces. We previously developed an approach to genetically program cells to assemble structures that modify electrical properties of neurons in situ, opening up the possibility of building minimally invasive cell-specific structures and interfaces. However, the efficiency and biocompatibility of this approach were challenged by limited membrane targeting of the constructed materials. Here, we design a method for highly localized expression of enzymes targeted to the plasma membrane of primary neurons, with minimal intracellular retention. Next, we show that polymers synthesized in situ by this approach form dense extracellular clusters selectively on the targeted cell membrane and that neurons remain viable after polymerization. Last, we show generalizability of this method across a range of design strategies. This platform can be readily extended to incorporate a broad diversity of materials onto specific cell membranes within tissues and may further enable next-generation biological interfaces.
Collapse
Affiliation(s)
- Anqi Zhang
- Department of Chemical Engineering, Stanford University, Stanford, CA 94305, USA
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
| | - Kang Yong Loh
- Department of Chemistry, Stanford Chemistry, Engineering and Medicine for Human Health (ChEM-H), Stanford University, Stanford, CA 94305, USA
| | - Chandan S. Kadur
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
| | - Lukas Michalek
- Department of Chemical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Jiayi Dou
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
| | - Charu Ramakrishnan
- CNC Program, School of Medicine, Stanford University, Stanford, CA 94305, USA
| | - Zhenan Bao
- Department of Chemical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Karl Deisseroth
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
- CNC Program, School of Medicine, Stanford University, Stanford, CA 94305, USA
- Department of Psychiatry and Behavioral Sciences, Stanford University, Stanford, CA 94305, USA
- Howard Hughes Medical Institute, Stanford University, Stanford, CA 94305, USA
| |
Collapse
|
5
|
Xue Y, Guo S, Wang A, Li Q, Li J, Bai S. Surface modification and cell behavior of electronic packaging materials PET. Colloids Surf A Physicochem Eng Asp 2023. [DOI: 10.1016/j.colsurfa.2023.131212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
|
6
|
Strakosas X, Biesmans H, Abrahamsson T, Hellman K, Ejneby MS, Donahue MJ, Ekström P, Ek F, Savvakis M, Hjort M, Bliman D, Linares M, Lindholm C, Stavrinidou E, Gerasimov JY, Simon DT, Olsson R, Berggren M. Metabolite-induced in vivo fabrication of substrate-free organic bioelectronics. Science 2023; 379:795-802. [PMID: 36821679 DOI: 10.1126/science.adc9998] [Citation(s) in RCA: 22] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
Abstract
Interfacing electronics with neural tissue is crucial for understanding complex biological functions, but conventional bioelectronics consist of rigid electrodes fundamentally incompatible with living systems. The difference between static solid-state electronics and dynamic biological matter makes seamless integration of the two challenging. To address this incompatibility, we developed a method to dynamically create soft substrate-free conducting materials within the biological environment. We demonstrate in vivo electrode formation in zebrafish and leech models, using endogenous metabolites to trigger enzymatic polymerization of organic precursors within an injectable gel, thereby forming conducting polymer gels with long-range conductivity. This approach can be used to target specific biological substructures and is suitable for nerve stimulation, paving the way for fully integrated, in vivo-fabricated electronics within the nervous system.
Collapse
Affiliation(s)
- Xenofon Strakosas
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
- Chemical Biology and Therapeutics, Department of Experimental Medical Science, Lund University, SE-221 84 Lund, Sweden
| | - Hanne Biesmans
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| | - Tobias Abrahamsson
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| | - Karin Hellman
- Chemical Biology and Therapeutics, Department of Experimental Medical Science, Lund University, SE-221 84 Lund, Sweden
| | - Malin Silverå Ejneby
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| | - Mary J Donahue
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| | - Peter Ekström
- Chemical Biology and Therapeutics, Department of Experimental Medical Science, Lund University, SE-221 84 Lund, Sweden
| | - Fredrik Ek
- Chemical Biology and Therapeutics, Department of Experimental Medical Science, Lund University, SE-221 84 Lund, Sweden
| | - Marios Savvakis
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| | - Martin Hjort
- Chemical Biology and Therapeutics, Department of Experimental Medical Science, Lund University, SE-221 84 Lund, Sweden
| | - David Bliman
- Department of Chemistry and Molecular Biology, University of Gothenburg, SE-405 30 Gothenburg, Sweden
- IRLAB Therapeutics AB, Arvid Wallgrens Backe 20, 413 46 Gothenburg, Sweden
| | - Mathieu Linares
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
- Scientific Visualization Group, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| | - Caroline Lindholm
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| | - Eleni Stavrinidou
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| | - Jennifer Y Gerasimov
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| | - Daniel T Simon
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| | - Roger Olsson
- Chemical Biology and Therapeutics, Department of Experimental Medical Science, Lund University, SE-221 84 Lund, Sweden
- Department of Chemistry and Molecular Biology, University of Gothenburg, SE-405 30 Gothenburg, Sweden
| | - Magnus Berggren
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| |
Collapse
|
7
|
Inal S. Turning tissues into conducting matter. Science 2023; 379:758-759. [PMID: 36821689 DOI: 10.1126/science.adg4761] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
Abstract
An electrically conducting soft polymer is synthesized within living tissue.
Collapse
Affiliation(s)
- Sahika Inal
- Biological and Environmental Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia
| |
Collapse
|
8
|
Chen HL, Yang D, Chen CR, Tian GZ, Kim DH. In situ polymerization of conducting polymers around living neural cells: Cellular effect study. Colloids Surf B Biointerfaces 2022; 213:112410. [PMID: 35176603 DOI: 10.1016/j.colsurfb.2022.112410] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 01/24/2022] [Accepted: 02/10/2022] [Indexed: 10/19/2022]
Abstract
Conducting polymer has been directly polymerized around living neural cells or in the cortex with the aim of creating an intimate contact between implantable electrical devices and electrogenetic cells. The long term cellular effect after conductive polymer coating, a critical issue for practical applications, has not been reported. In this study, poly(3,4-ethylenedioxythiophene) PEDOT was directly polymerized around the living primary neural and PC12 cells under varying current densities, potentials and charge-balanced current pulses. The cell morphology, nuclei evolution, and cell viability post PEDOT polymerization were studied at different time points. The aim of this study was to investigate the immediate and long-term cellular response towards in-situ polymerization of conductive polymers and to provide experimental information on the feasibility of this technique in practical applications.
Collapse
Affiliation(s)
- Hai-Lan Chen
- School of Animal Science and Technology, Guangxi University, Nanning 530004, Guangxi, People's Republic of China.
| | - Dan Yang
- School of Animal Science and Technology, Guangxi University, Nanning 530004, Guangxi, People's Republic of China
| | - Chun-Rong Chen
- School of Animal Science and Technology, Guangxi University, Nanning 530004, Guangxi, People's Republic of China
| | - Guang-Zhao Tian
- School of Animal Science and Technology, Guangxi University, Nanning 530004, Guangxi, People's Republic of China
| | - Dong-Hwan Kim
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea; Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea.
| |
Collapse
|
9
|
Manousiouthakis E, Park J, Hardy JG, Lee JY, Schmidt CE. Towards the translation of electroconductive organic materials for regeneration of neural tissues. Acta Biomater 2022; 139:22-42. [PMID: 34339871 DOI: 10.1016/j.actbio.2021.07.065] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 07/23/2021] [Accepted: 07/27/2021] [Indexed: 12/13/2022]
Abstract
Carbon-based conductive and electroactive materials (e.g., derivatives of graphene, fullerenes, polypyrrole, polythiophene, polyaniline) have been studied since the 1970s for use in a broad range of applications. These materials have electrical properties comparable to those of commonly used metals, while providing other benefits such as flexibility in processing and modification with biologics (e.g., cells, biomolecules), to yield electroactive materials with biomimetic mechanical and chemical properties. In this review, we focus on the uses of these electroconductive materials in the context of the central and peripheral nervous system, specifically recent studies in the peripheral nerve, spinal cord, brain, eye, and ear. We also highlight in vivo studies and clinical trials, as well as a snapshot of emerging classes of electroconductive materials (e.g., biodegradable materials). We believe such specialized electrically conductive biomaterials will clinically impact the field of tissue regeneration in the foreseeable future. STATEMENT OF SIGNIFICANCE: This review addresses the use of conductive and electroactive materials for neural tissue regeneration, which is of significant interest to a broad readership, and of particular relevance to the growing community of scientists, engineers and clinicians in academia and industry who develop novel medical devices for tissue engineering and regenerative medicine. The review covers the materials that may be employed (primarily focusing on derivatives of fullerenes, graphene and conjugated polymers) and techniques used to analyze materials composed thereof, followed by sections on the application of these materials to nervous tissues (i.e., peripheral nerve, spinal cord, brain, optical, and auditory tissues) throughout the body.
Collapse
Affiliation(s)
- Eleana Manousiouthakis
- Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville 32611, FL, United States
| | - Junggeon Park
- School of Materials Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea
| | - John G Hardy
- Department of Chemistry, Lancaster University, Lancaster LA1 4YB, United Kingdom; Materials Science Institute, Lancaster University, Lancaster LA1 4YB, United Kingdom.
| | - Jae Young Lee
- School of Materials Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea.
| | - Christine E Schmidt
- Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville 32611, FL, United States.
| |
Collapse
|
10
|
Abstract
![]()
Electronically interfacing with the
nervous system for the purposes
of health diagnostics and therapy, sports performance monitoring,
or device control has been a subject of intense academic and industrial
research for decades. This trend has only increased in recent years,
with numerous high-profile research initiatives and commercial endeavors.
An important research theme has emerged as a result, which is the
incorporation of semiconducting polymers in various devices that communicate
with the nervous system—from wearable brain-monitoring caps
to penetrating implantable microelectrodes. This has been driven by
the potential of this broad class of materials to improve the electrical
and mechanical properties of the tissue–device interface, along
with possibilities for increased biocompatibility. In this review
we first begin with a tutorial on neural interfacing, by reviewing
the basics of nervous system function, device physics, and neuroelectrophysiological
techniques and their demands, and finally we give a brief perspective
on how material improvements can address current deficiencies in this
system. The second part is a detailed review of past work on semiconducting
polymers, covering electrical properties, structure, synthesis, and
processing.
Collapse
Affiliation(s)
- Ivan B Dimov
- Electrical Engineering Division, Department of Engineering, University of Cambridge, 9 JJ Thomson Avenue, Cambridge CB3 0FA, U.K
| | - Maximilian Moser
- University of Oxford, Department of Chemistry, Oxford OX1 3TA, United Kingdom
| | - George G Malliaras
- Electrical Engineering Division, Department of Engineering, University of Cambridge, 9 JJ Thomson Avenue, Cambridge CB3 0FA, U.K
| | - Iain McCulloch
- University of Oxford, Department of Chemistry, Oxford OX1 3TA, United Kingdom.,King Abdullah University of Science and Technology (KAUST), KAUST Solar Center, Thuwal 23955-6900, Saudi Arabia
| |
Collapse
|
11
|
Flexible Neural Probes with Optical Artifact-Suppressing Modification and Biofriendly Polypeptide Coating. MICROMACHINES 2022; 13:mi13020199. [PMID: 35208323 PMCID: PMC8877708 DOI: 10.3390/mi13020199] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 01/23/2022] [Accepted: 01/23/2022] [Indexed: 11/24/2022]
Abstract
The advent of optogenetics provides a well-targeted tool to manipulate neurons because of its high time resolution and cell-type specificity. Recently, closed-loop neural manipulation techniques consisting of optical stimulation and electrical recording have been widely used. However, metal microelectrodes exposed to light radiation could generate photoelectric noise, thus causing loss or distortion of neural signal in recording channels. Meanwhile, the biocompatibility of neural probes remains to be improved. Here, five kinds of neural interface materials are deposited on flexible polyimide-based neural probes and illuminated with a series of blue laser pulses to study their electrochemical performance and photoelectric noises for single-unit recording. The results show that the modifications can not only improve the electrochemical performance, but can also reduce the photoelectric artifacts. In particular, the double-layer composite consisting of platinum-black and conductive polymer has the best comprehensive performance. Thus, a layer of polypeptide is deposited on the entire surface of the double-layer modified neural probes to further improve their biocompatibility. The results show that the biocompatible polypeptide coating has little effect on the electrochemical performance of the neural probe, and it may serve as a drug carrier due to its special micromorphology.
Collapse
|
12
|
Berggren M, Głowacki ED, Simon DT, Stavrinidou E, Tybrandt K. In Vivo Organic Bioelectronics for Neuromodulation. Chem Rev 2022; 122:4826-4846. [PMID: 35050623 PMCID: PMC8874920 DOI: 10.1021/acs.chemrev.1c00390] [Citation(s) in RCA: 39] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
![]()
The nervous system
poses a grand challenge for integration with
modern electronics and the subsequent advances in neurobiology, neuroprosthetics,
and therapy which would become possible upon such integration. Due
to its extreme complexity, multifaceted signaling pathways, and ∼1
kHz operating frequency, modern complementary metal oxide semiconductor
(CMOS) based electronics appear to be the only technology platform
at hand for such integration. However, conventional CMOS-based electronics
rely exclusively on electronic signaling and therefore require an
additional technology platform to translate electronic signals into
the language of neurobiology. Organic electronics are just such a
technology platform, capable of converting electronic addressing into
a variety of signals matching the endogenous signaling of the nervous
system while simultaneously possessing favorable material similarities
with nervous tissue. In this review, we introduce a variety of organic
material platforms and signaling modalities specifically designed
for this role as “translator”, focusing especially on
recent implementation in in vivo neuromodulation.
We hope that this review serves both as an informational resource
and as an encouragement and challenge to the field.
Collapse
Affiliation(s)
- Magnus Berggren
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| | - Eric D Głowacki
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden.,Bioelectronics Materials and Devices, Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00 Brno, Czech Republic
| | - Daniel T Simon
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| | - Eleni Stavrinidou
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| | - Klas Tybrandt
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74 Norrköping, Sweden
| |
Collapse
|
13
|
Liu Y, Feig VR, Bao Z. Conjugated Polymer for Implantable Electronics toward Clinical Application. Adv Healthc Mater 2021; 10:e2001916. [PMID: 33899347 DOI: 10.1002/adhm.202001916] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 12/13/2020] [Indexed: 12/21/2022]
Abstract
Owing to their excellent mechanical flexibility, mixed-conducting electrical property, and extraordinary chemical turnability, conjugated polymers have been demonstrated to be an ideal bioelectronic interface to deliver therapeutic effect in many different chronic diseases. This review article summarizes the latest advances in implantable electronics using conjugated polymers as electroactive materials and identifies remaining challenges and opportunities for developing electronic medicine. Examples of conjugated polymer-based bioelectronic devices are selectively reviewed in human clinical studies or animal studies with the potential for clinical adoption. The unique properties of conjugated polymers are highlighted and exemplified as potential solutions to address the specific challenges in electronic medicine.
Collapse
Affiliation(s)
- Yuxin Liu
- Institute of Materials Research and Engineering Agency for Science, Technology and Research Singapore 138634 Singapore
| | - Vivian Rachel Feig
- Division of Gastroenterology, Department of Medicine, Brigham and Women’s Hospital Harvard Medical School Boston MA 02115 USA
| | - Zhenan Bao
- Department of Chemical Engineering Stanford University Stanford CA 94305 USA
| |
Collapse
|
14
|
Subramanian V, Martin DC. Direct Observation of Liquid-to-Solid Phase Transformations during the Electrochemical Deposition of Poly(3,4-ethylenedioxythiophene) (PEDOT) by Liquid-Phase Transmission Electron Microscopy (LPTEM). Macromolecules 2021. [DOI: 10.1021/acs.macromol.1c00404] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Affiliation(s)
- Vivek Subramanian
- Department of Materials Science and Engineering, The University of Delaware, Newark, Delaware 19716, United States
| | - David C. Martin
- Department of Materials Science and Engineering, The University of Delaware, Newark, Delaware 19716, United States
- Department of Biomedical Engineering, The University of Delaware, Newark, Delaware 19716, United States
| |
Collapse
|
15
|
Phillips JA, Hutchings C, Djamgoz MBA. Clinical Potential of Nerve Input to Tumors: A Bioelectricity Perspective. Bioelectricity 2021; 3:14-26. [PMID: 34476375 DOI: 10.1089/bioe.2020.0051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Abstract
We support the notion that the neural connections of the tumor microenvironment (TME) and the associated 'bioelectricity' play significant role in the pathophysiology of cancer. In several cancers, the nerve input promotes the cancer process. While straightforward surgical denervation of tumors, therefore, could improve prognosis, resulting side effects of such a procedure would be unpredictable and irreversible. On the other hand, tumor innervation can be manipulated effectively for therapeutic purposes by alternative novel approaches broadly termed "electroceuticals." In this perspective, we evaluate the clinical potential of targeting the TME first through manipulation of the nerve input itself and second by application of electric fields directly to the tumor. The former encompasses several different biophysical and biochemical approaches. These include implantable devices, nanoparticles, and electroactive polymers, as well as optogenetics and chemogenetics. As regard bioelectrical manipulation of the tumor itself, the "tumor-treating field" technique, applied to gliomas commonly in combination with chemotherapy, is evaluated. Also, as electroceuticals, drugs acting on ion channels and neurotransmitter receptors are highlighted for completeness. It is concluded, first, that electroceuticals comprise a broad range of biomedical tools. Second, such electroceuticals present significant clinical potential for exploiting the neural component of the TME as a strategy against cancer. Finally, the inherent bioelectric characteristics of tumors themselves are also amenable to complementary approaches. Collectively, these represent an evolving, dynamic field and further progress and applications can be expected to follow both conceptually and technically.
Collapse
Affiliation(s)
- Jade A Phillips
- Department of Life Sciences, Imperial College London, London, United Kingdom
| | - Charlotte Hutchings
- Department of Life Sciences, Imperial College London, London, United Kingdom
| | - Mustafa B A Djamgoz
- Department of Life Sciences, Imperial College London, London, United Kingdom.,Biotechnology Research Center, Cyprus International University, Nicosia, North Cyprus
| |
Collapse
|
16
|
How is flexible electronics advancing neuroscience research? Biomaterials 2020; 268:120559. [PMID: 33310538 DOI: 10.1016/j.biomaterials.2020.120559] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 11/16/2020] [Accepted: 11/18/2020] [Indexed: 02/07/2023]
Abstract
Innovative neurotechnology must be leveraged to experimentally answer the multitude of pressing questions in modern neuroscience. Driven by the desire to address the existing neuroscience problems with newly engineered tools, we discuss in this review the benefits of flexible electronics for neuroscience studies. We first introduce the concept and define the properties of flexible and stretchable electronics. We then categorize the four dimensions where flexible electronics meets the demands of modern neuroscience: chronic stability, interfacing multiple structures, multi-modal compatibility, and neuron-type-specific recording. Specifically, with the bending stiffness now approaching that of neural tissue, implanted flexible electronic devices produce little shear motion, minimizing chronic immune responses and enabling recording and stimulation for months, and even years. The unique mechanical properties of flexible electronics also allow for intimate conformation to the brain, the spinal cord, peripheral nerves, and the retina. Moreover, flexible electronics enables optogenetic stimulation, microfluidic drug delivery, and neural activity imaging during electrical stimulation and recording. Finally, flexible electronics can enable neuron-type identification through analysis of high-fidelity recorded action potentials facilitated by its seamless integration with the neural circuitry. We argue that flexible electronics will play an increasingly important role in neuroscience studies and neurological therapies via the fabrication of neuromorphic devices on flexible substrates and the development of enhanced methods of neuronal interpenetration.
Collapse
|
17
|
Low ZWK, Li Z, Owh C, Chee PL, Ye E, Dan K, Chan SY, Young DJ, Loh XJ. Recent innovations in artificial skin. Biomater Sci 2020; 8:776-797. [PMID: 31820749 DOI: 10.1039/c9bm01445d] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The skin is a "smart", multifunctional organ that is protective, self-healing and capable of sensing and many forms of artificial skins have been developed with properties and functionalities approximating those of natural skin. Starting from specific commercial products for the treatment of burns, progress in two fields of research has since allowed these remarkable materials to be viable skin replacements for a wide range of dermatological conditions. This review maps out the development of bioengineered skin replacements and synthetic skin substitutes, including electronic skins. The specific behaviors of these skins are highlighted, and the performances of both types of artificial skins are evaluated against this. Moving beyond mere replication, highly advanced artificial skin materials are also identified as potential augmented skins that can be used as flexible electronics for health-care monitoring and other applications.
Collapse
Affiliation(s)
- Zhi Wei Kenny Low
- Institute of Materials Research and Engineering, A*STAR, 2Fusionopolis Way, Innovis, #08-03, Singapore 138634.
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Parashar K, Prajapati D, McIntyre R, Kandasubramanian B. Advancements in Biological Neural Interfaces Using Conducting Polymers: A Review. Ind Eng Chem Res 2020. [DOI: 10.1021/acs.iecr.0c00174] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Kashish Parashar
- Nanofabrication and Characterization Lab, Centre for Converging Technologies, University of Rajasthan, JLN Marg, Jaipur-302004, India
| | - Deepak Prajapati
- Material Science and Engineering, Indian Institute of Technology, Gandhinagar, Gujarat 382355, India
| | | | - Balasubramanian Kandasubramanian
- Nano Surface Texturing Lab, Dept. of Metallurgical and Materials Engineering, Defence Institute of Advanced Technology (DIAT), Ministry of Defence, DRDO, Girinagar, Pune-411025, India
| |
Collapse
|
19
|
Keef CV, Kayser LV, Tronboll S, Carpenter CW, Root NB, Finn M, O’Connor TF, Abuhamdieh SN, Davies DM, Runser R, Meng YS, Ramachandran VS, Lipomi DJ. Virtual Texture Generated using Elastomeric Conductive Block Copolymer in Wireless Multimodal Haptic Glove. ADVANCED INTELLIGENT SYSTEMS (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 2:2000018. [PMID: 32656536 PMCID: PMC7351316 DOI: 10.1002/aisy.202000018] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Indexed: 05/03/2023]
Abstract
Haptic devices are in general more adept at mimicking the bulk properties of materials than they are at mimicking the surface properties. This paper describes a haptic glove capable of producing sensations reminiscent of three types of near-surface properties: hardness, temperature, and roughness. To accomplish this mixed mode of stimulation, three types of haptic actuators were combined: vibrotactile motors, thermoelectric devices, and electrotactile electrodes made from a stretchable conductive polymer synthesized in our laboratory. This polymer consisted of a stretchable polyanion which served as a scaffold for the polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT). The scaffold was synthesized using controlled radical polymerization to afford material of low dispersity, relatively high conductivity (0.1 S cm-1), and low impedance relative to metals. The glove was equipped with flex sensors to make it possible to control a robotic hand and a hand in virtual reality (VR). In psychophysical experiments, human participants were able to discern combinations of electrotactile, vibrotactile, and thermal stimulation in VR. Participants trained to associate these sensations with roughness, hardness, and temperature had an overall accuracy of 98%, while untrained participants had an accuracy of 85%. Sensations could similarly be conveyed using a robotic hand equipped with sensors for pressure and temperature.
Collapse
Affiliation(s)
- Colin V. Keef
- Department of Electrical and Computer Engineering,
University of California, San Diego, Mail Code 0407, La Jolla, CA 92093-0407
| | - Laure V. Kayser
- Department of NanoEngineering and Program in Chemical
Engineering, University of California, San Diego, Mail Code 0448, La Jolla, CA
92093-0448
| | - Stazia Tronboll
- Department of Electrical and Computer Engineering,
University of California, San Diego, Mail Code 0407, La Jolla, CA 92093-0407
| | - Cody W. Carpenter
- Department of NanoEngineering and Program in Chemical
Engineering, University of California, San Diego, Mail Code 0448, La Jolla, CA
92093-0448
| | - Nicholas B. Root
- Department of Psychology, University of California, San
Diego, Mail Code 0109, La Jolla, CA 92093-0109
| | - Mickey Finn
- Department of NanoEngineering and Program in Chemical
Engineering, University of California, San Diego, Mail Code 0448, La Jolla, CA
92093-0448
| | - Timothy F. O’Connor
- Department of NanoEngineering and Program in Chemical
Engineering, University of California, San Diego, Mail Code 0448, La Jolla, CA
92093-0448
| | - Sami N. Abuhamdieh
- Department of NanoEngineering and Program in Chemical
Engineering, University of California, San Diego, Mail Code 0448, La Jolla, CA
92093-0448
| | - Daniel M. Davies
- Department of NanoEngineering and Program in Chemical
Engineering, University of California, San Diego, Mail Code 0448, La Jolla, CA
92093-0448
| | - Rory Runser
- Department of NanoEngineering and Program in Chemical
Engineering, University of California, San Diego, Mail Code 0448, La Jolla, CA
92093-0448
| | - Y. Shirley Meng
- Department of NanoEngineering and Program in Chemical
Engineering, University of California, San Diego, Mail Code 0448, La Jolla, CA
92093-0448
| | - Vilayanur S. Ramachandran
- Department of Psychology, University of California, San
Diego, Mail Code 0109, La Jolla, CA 92093-0109
| | - Darren J. Lipomi
- Department of NanoEngineering and Program in Chemical
Engineering, University of California, San Diego, Mail Code 0448, La Jolla, CA
92093-0448
| |
Collapse
|
20
|
Liu J, Kim YS, Richardson CE, Tom A, Ramakrishnan C, Birey F, Katsumata T, Chen S, Wang C, Wang X, Joubert LM, Jiang Y, Wang H, Fenno LE, Tok JBH, Pașca SP, Shen K, Bao Z, Deisseroth K. Genetically targeted chemical assembly of functional materials in living cells, tissues, and animals. Science 2020; 367:1372-1376. [PMID: 32193327 DOI: 10.1126/science.aay4866] [Citation(s) in RCA: 99] [Impact Index Per Article: 24.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2019] [Accepted: 01/21/2020] [Indexed: 12/30/2022]
Abstract
The structural and functional complexity of multicellular biological systems, such as the brain, are beyond the reach of human design or assembly capabilities. Cells in living organisms may be recruited to construct synthetic materials or structures if treated as anatomically defined compartments for specific chemistry, harnessing biology for the assembly of complex functional structures. By integrating engineered-enzyme targeting and polymer chemistry, we genetically instructed specific living neurons to guide chemical synthesis of electrically functional (conductive or insulating) polymers at the plasma membrane. Electrophysiological and behavioral analyses confirmed that rationally designed, genetically targeted assembly of functional polymers not only preserved neuronal viability but also achieved remodeling of membrane properties and modulated cell type-specific behaviors in freely moving animals. This approach may enable the creation of diverse, complex, and functional structures and materials within living systems.
Collapse
Affiliation(s)
- Jia Liu
- Department of Chemical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Yoon Seok Kim
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
| | | | - Ariane Tom
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
| | - Charu Ramakrishnan
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
| | - Fikri Birey
- Department of Psychiatry, Stanford University, Stanford, CA 94305, USA
| | - Toru Katsumata
- Department of Chemical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Shucheng Chen
- Department of Chemical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Cheng Wang
- Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley CA 94720, USA
| | - Xiao Wang
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
| | - Lydia-Marie Joubert
- Cell Sciences Imaging Facility, Stanford University, Stanford, CA 94305, USA
| | - Yuanwen Jiang
- Department of Chemical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Huiliang Wang
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
| | - Lief E Fenno
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA.,Department of Psychiatry, Stanford University, Stanford, CA 94305, USA
| | - Jeffrey B-H Tok
- Department of Chemical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Sergiu P Pașca
- Department of Psychiatry, Stanford University, Stanford, CA 94305, USA
| | - Kang Shen
- Department of Biology, Stanford University, Stanford, CA 94305, USA.,Howard Hughes Medical Institute, Stanford University, Stanford, CA 94305, USA
| | - Zhenan Bao
- Department of Chemical Engineering, Stanford University, Stanford, CA 94305, USA.
| | - Karl Deisseroth
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA. .,Department of Psychiatry, Stanford University, Stanford, CA 94305, USA.,Howard Hughes Medical Institute, Stanford University, Stanford, CA 94305, USA
| |
Collapse
|
21
|
Affiliation(s)
- Kevin J Otto
- J. Crayton Pruitt Family Department of Biomedical Engineering, Herbert Wertheim College of Engineering, University of Florida, Gainesville, FL, USA.
| | - Christine E Schmidt
- J. Crayton Pruitt Family Department of Biomedical Engineering, Herbert Wertheim College of Engineering, University of Florida, Gainesville, FL, USA.
| |
Collapse
|
22
|
Oribe S, Yoshida S, Kusama S, Osawa SI, Nakagawa A, Iwasaki M, Tominaga T, Nishizawa M. Hydrogel-Based Organic Subdural Electrode with High Conformability to Brain Surface. Sci Rep 2019; 9:13379. [PMID: 31527626 PMCID: PMC6746719 DOI: 10.1038/s41598-019-49772-z] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 08/28/2019] [Indexed: 11/16/2022] Open
Abstract
A totally soft organic subdural electrode has been developed by embedding an array of poly(3,4-ethylenedioxythiophene)-modified carbon fabric (PEDOT-CF) into the polyvinyl alcohol (PVA) hydrogel substrate. The mesh structure of the stretchable PEDOT-CF allowed stable structural integration with the PVA substrate. The electrode performance for monitoring electrocorticography (ECoG) was evaluated in saline solution, on ex vivo brains, and in vivo animal experiments using rats and porcines. It was demonstrated that the large double-layer capacitance of the PEDOT-CF brings low impedance at the frequency of brain wave including epileptic seizures, and PVA hydrogel substrate minimized the contact impedance on the brain. The most important unique feature of the hydrogel-based ECoG electrode was its shape conformability to enable tight adhesion even to curved, grooved surface of brains by just being placed. In addition, since the hydrogel-based electrode is totally organic, the simultaneous ECoG-fMRI measurements could be conducted without image artifacts, avoiding problems induced by conventional metallic electrodes.
Collapse
Affiliation(s)
- Shuntaro Oribe
- Department of Neurosurgery, Graduate School of Medicine, Tohoku University, 2-1 Seiryo-machi, Aoba-ku, Sendai, 980-8575, Japan
| | - Shotaro Yoshida
- Department of Finemechanics, Graduate School of Engineering, Tohoku University, 6-6-01 Aramaki-Aoba, Aoba-ku, Sendai, 980-8579, Japan
| | - Shinya Kusama
- Department of Finemechanics, Graduate School of Engineering, Tohoku University, 6-6-01 Aramaki-Aoba, Aoba-ku, Sendai, 980-8579, Japan
| | - Shin-Ichiro Osawa
- Department of Neurosurgery, Graduate School of Medicine, Tohoku University, 2-1 Seiryo-machi, Aoba-ku, Sendai, 980-8575, Japan
| | - Atsuhiro Nakagawa
- Department of Neurosurgery, Graduate School of Medicine, Tohoku University, 2-1 Seiryo-machi, Aoba-ku, Sendai, 980-8575, Japan
| | - Masaki Iwasaki
- Department of Neurosurgery, National Center Hospital, National Center of Neurology and Psychiatry (NCNP), 4-1-1 Ogawahigashi-cho, Kodaira-shi, Tokyo, 187-8551, Japan
| | - Teiji Tominaga
- Department of Neurosurgery, Graduate School of Medicine, Tohoku University, 2-1 Seiryo-machi, Aoba-ku, Sendai, 980-8575, Japan
| | - Matsuhiko Nishizawa
- Department of Finemechanics, Graduate School of Engineering, Tohoku University, 6-6-01 Aramaki-Aoba, Aoba-ku, Sendai, 980-8579, Japan.
| |
Collapse
|
23
|
Müller C, Ouyang L, Lund A, Moth-Poulsen K, Hamedi MM. From Single Molecules to Thin Film Electronics, Nanofibers, e-Textiles and Power Cables: Bridging Length Scales with Organic Semiconductors. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2019; 31:e1807286. [PMID: 30785223 DOI: 10.1002/adma.201807286] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Revised: 12/19/2018] [Indexed: 05/22/2023]
Abstract
Organic semiconductors are the centerpiece of several vibrant research fields from single-molecule to organic electronics, and they are finding increasing use in bioelectronics and even classical polymer technology. The versatile chemistry and broad range of electronic functionalities of conjugated materials enable the bridging of length scales 15 orders of magnitude apart, ranging from a single nanometer (10-9 m) to the size of continents (106 m). This work provides a taste of the diverse applications that can be realized with organic semiconductors. The reader will embark on a journey from single molecular junctions to thin film organic electronics, supramolecular assemblies, biomaterials such as amyloid fibrils and nanofibrillated cellulose, conducting fibers and yarns for e-textiles, and finally to power cables that shuffle power across thousands of kilometers.
Collapse
Affiliation(s)
- Christian Müller
- Department of Chemistry and Chemical Engineering, Chalmers University of Technology, 412 96, Göteborg, Sweden
| | - Liangqi Ouyang
- Fibre and Polymer Technology, KTH Royal Institute of Technology, 100 44 Stockholm, Sweden
| | - Anja Lund
- Department of Chemistry and Chemical Engineering, Chalmers University of Technology, 412 96, Göteborg, Sweden
| | - Kasper Moth-Poulsen
- Department of Chemistry and Chemical Engineering, Chalmers University of Technology, 412 96, Göteborg, Sweden
| | - Mahiar M Hamedi
- Fibre and Polymer Technology, KTH Royal Institute of Technology, 100 44 Stockholm, Sweden
| |
Collapse
|
24
|
Low ZWK, Li Z, Owh C, Chee PL, Ye E, Kai D, Yang DP, Loh XJ. Using Artificial Skin Devices as Skin Replacements: Insights into Superficial Treatment. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1805453. [PMID: 30690897 DOI: 10.1002/smll.201805453] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Indexed: 06/09/2023]
Abstract
Artificial skin devices are able to mimic the flexibility and sensory perception abilities of the skin. They have thus garnered attention in the biomedical field as potential skin replacements. This Review delves into issues pertaining to these skin-deep devices. It first elaborates on the roles that these devices have to fulfill as skin replacements, and identify strategies that are used to achieve such functionality. Following which, a comparison is done between the current state of these skin-deep devices and that of natural skin. Finally, an outlook on artificial skin devices is presented, which discusses how complementary technologies can create skin enhancements, and what challenges face such devices.
Collapse
Affiliation(s)
- Zhi Wei Kenny Low
- Institute of Materials Research and Engineering, 2 Fusionopolis Way, Innovis, #08-03, Singapore, 138634, Singapore
- Department of Materials Science and Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117576, Singapore
| | - Zibiao Li
- Institute of Materials Research and Engineering, 2 Fusionopolis Way, Innovis, #08-03, Singapore, 138634, Singapore
| | - Cally Owh
- Institute of Materials Research and Engineering, 2 Fusionopolis Way, Innovis, #08-03, Singapore, 138634, Singapore
- Department of Materials Science and Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117576, Singapore
| | - Pei Lin Chee
- Institute of Materials Research and Engineering, 2 Fusionopolis Way, Innovis, #08-03, Singapore, 138634, Singapore
- Department of Materials Science and Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117576, Singapore
| | - Enyi Ye
- Institute of Materials Research and Engineering, 2 Fusionopolis Way, Innovis, #08-03, Singapore, 138634, Singapore
| | - Dan Kai
- Institute of Materials Research and Engineering, 2 Fusionopolis Way, Innovis, #08-03, Singapore, 138634, Singapore
| | - Da-Peng Yang
- College of Chemical Engineering and Materials Science, Quanzhou Normal University, Quanzhou, 362000, Fujian Province, China
| | - Xian Jun Loh
- Institute of Materials Research and Engineering, 2 Fusionopolis Way, Innovis, #08-03, Singapore, 138634, Singapore
- Department of Materials Science and Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117576, Singapore
| |
Collapse
|
25
|
Murbach JM, Currlin S, Widener A, Tong Y, Chhatre S, Subramanian V, Martin DC, Johnson BN, Otto KJ. In situ electrochemical polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT) for peripheral nerve interfaces. MRS COMMUNICATIONS 2018; 8:1043-1049. [PMID: 34386296 PMCID: PMC8356669 DOI: 10.1557/mrc.2018.138] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Accepted: 07/12/2018] [Indexed: 06/13/2023]
Abstract
The goal of this study was to perform in situ electrochemical polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT) in peripheral nerves to create a soft, precisely located injectable conductive polymer electrode for bi-directional communication. Intraneural PEDOT polymerization was performed to target both outer and inner fascicles via custom fabricated 3D printed cuff electrodes and monomer injection strategies using a combination electrode-cannula system. Electrochemistry, histology, and laser light sheet microscopy revealed the presence of PEDOT at specified locations inside of peripheral nerve. This work demonstrates the potential for using in situ PEDOT electrodeposition as an injectable electrode for recording and stimulation of peripheral nerves.
Collapse
Affiliation(s)
- Jamie M Murbach
- Department of Materials Science and Engineering, University of Florida, Gainesville, FL 32611, USA
| | - Seth Currlin
- Department of Neuroscience, University of Florida, Gainesville, FL 32611, USA
| | - Adrienne Widener
- Department of Materials Science and Engineering, University of Florida, Gainesville, FL 32611, USA
| | - Yuxin Tong
- Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA 24061, USA
| | - Shrirang Chhatre
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - Vivek Subramanian
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - David C Martin
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - Blake N Johnson
- Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA 24061, USA
| | - Kevin J Otto
- Department of Materials Science and Engineering, University of Florida, Gainesville, FL 32611, USA; Department of Neuroscience, University of Florida, Gainesville, FL 32611, USA; J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611, USA; Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL 32611, USA
| |
Collapse
|
26
|
Rajnicek AM, Zhao Z, Moral-Vico J, Cruz AM, McCaig CD, Casañ-Pastor N. Controlling Nerve Growth with an Electric Field Induced Indirectly in Transparent Conductive Substrate Materials. Adv Healthc Mater 2018; 7:e1800473. [PMID: 29975820 DOI: 10.1002/adhm.201800473] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Revised: 06/05/2018] [Indexed: 11/05/2022]
Abstract
Innovative neurostimulation therapies require improved electrode materials, such as poly(3,4-ethylenedioxythiophene) (PEDOT) polymers or IrOx mixed ionic-electronic conductors and better understanding of how their electrochemistry influences nerve growth. Amphibian neurons growing on transparent films of electronic (metal) conductors and electronic-ionic conductors (polymers and semiconducting oxides) are monitored. Materials are not connected directly to the power supply, but a dipole is created wirelessly within them by electrodes connected to the culture medium in which they are immersed. Without electrical stimulation neurons grow on gold, platinum, PEDOT-polystyrene sulfonate (PEDOT-PSS), IrOx , and mixed oxide (Ir-Ti)Ox , but growth is not related to surface texture or hydrophilicity. Stimulation induces a dipole in all conductive materials, but neurons grow differently on electronic conductors and mixed-valence mixed-ionic conductors. Stimulation slows, but steers neurite extension on gold but not on platinum. The rate and direction of neurite growth on PEDOT-PSS resemble that on glass, but on IrOx and (Ir-Ti)Ox neurites grow faster and in random directions. This suggests electrochemical changes induced in these materials control growth speed and direction selectively. Evidence that the electric dipole induced in conductive material controls nerve growth will impact electrotherapies exploiting wireless stimulation of implanted material arrays, even where transparency is required.
Collapse
Affiliation(s)
- Ann M. Rajnicek
- School of Medicine, Medical Sciences and Nutrition; Institute of Medical Sciences; University of Aberdeen; Aberdeen AB25 2ZD UK
| | - Zhiqiang Zhao
- School of Medicine, Medical Sciences and Nutrition; Institute of Medical Sciences; University of Aberdeen; Aberdeen AB25 2ZD UK
| | - Javier Moral-Vico
- Instituto de Ciencia de Materiales de Barcelona; CSIC; Campus de la Universidad Autónoma de Barcelona; E-08193 Barcelona Spain
| | - Ana M. Cruz
- Instituto de Ciencia de Materiales de Barcelona; CSIC; Campus de la Universidad Autónoma de Barcelona; E-08193 Barcelona Spain
| | - Colin D. McCaig
- School of Medicine, Medical Sciences and Nutrition; Institute of Medical Sciences; University of Aberdeen; Aberdeen AB25 2ZD UK
| | - Nieves Casañ-Pastor
- Instituto de Ciencia de Materiales de Barcelona; CSIC; Campus de la Universidad Autónoma de Barcelona; E-08193 Barcelona Spain
| |
Collapse
|
27
|
Franco-Gonzalez JF, Pavlopoulou E, Stavrinidou E, Gabrielsson R, Simon DT, Berggren M, Zozoulenko IV. Morphology of a self-doped conducting oligomer for green energy applications. NANOSCALE 2017; 9:13717-13724. [PMID: 28884179 DOI: 10.1039/c7nr04617k] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
A recently synthesized self-doped conducting oligomer, salt of bis[3,4-ethylenedioxythiophene]3thiophene butyric acid, ETE-S, is a novel promising material for green energy applications. Recently, it has been demonstrated that it can polymerize in vivo, in plant systems, leading to a formation of long-range conducting wires, charge storage and supercapacitive behaviour of living plants. Here we investigate the morphology of ETE-S combining the experimental characterisation using Grazing Incidence Wide Angle X-ray Scattering (GIWAXS) and atomistic molecular dynamics (MD) simulations. The GIWAXS measurements reveal a formation of small crystallites consisting of π-π stacked oligomers (with the staking distance 3.5 Å) that are further organized in h00 lamellae. These experimental results are confirmed by MD calculations, where we calculated the X-ray diffraction pattern and the radial distribution function for the distance between ETE-S chains. Our MD simulations also demonstrate the formation of the percolative paths for charge carriers that extend throughout the whole structure, despite the fact that the oligomers are short (6-9 rings) and crystallites are thin along the π-π stacking direction, consisting of only two or three π-π stacked oligomers. The existence of the percolative paths explains the previously observed high conductivity in in vivo polymerized ETE-S. We also explored the geometrical conformation of ETE-S oligomers and the bending of their aliphatic chains as a function of the oligomer lengths.
Collapse
Affiliation(s)
- Juan Felipe Franco-Gonzalez
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, SE-601 74 Norrköping, Sweden.
| | | | | | | | | | | | | |
Collapse
|
28
|
Abstract
Plastic bioelectronics is a research field that takes advantage of the inherent properties of polymers and soft organic electronics for applications at the interface of biology and electronics. The resulting electronic materials and devices are soft, stretchable and mechanically conformable, which are important qualities for interacting with biological systems in both wearable and implantable devices. Work is currently aimed at improving these devices with a view to making the electronic-biological interface as seamless as possible.
Collapse
|
29
|
Ouyang L, Wei B, Kuo CC, Pathak S, Farrell B, Martin DC. Enhanced PEDOT adhesion on solid substrates with electrografted P(EDOT-NH 2). SCIENCE ADVANCES 2017; 3:e1600448. [PMID: 28275726 PMCID: PMC5336355 DOI: 10.1126/sciadv.1600448] [Citation(s) in RCA: 70] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Accepted: 01/27/2017] [Indexed: 05/29/2023]
Abstract
Conjugated polymers, such as poly(3,4-ethylene dioxythiophene) (PEDOT), have emerged as promising materials for interfacing biomedical devices with tissue because of their relatively soft mechanical properties, versatile organic chemistry, and inherent ability to conduct both ions and electrons. However, their limited adhesion to substrates is a concern for in vivo applications. We report an electrografting method to create covalently bonded PEDOT on solid substrates. An amine-functionalized EDOT derivative (2,3-dihydrothieno[3,4-b][1,4]dioxin-2-yl)methanamine (EDOT-NH2), was synthesized and then electrografted onto conducting substrates including platinum, iridium, and indium tin oxide. The electrografting process was performed under slightly basic conditions with an overpotential of ~2 to 3 V. A nonconjugated, cross-linked, and well-adherent P(EDOT-NH2)-based polymer coating was obtained. We found that the P(EDOT-NH2) polymer coating did not block the charge transport through the interface. Subsequent PEDOT electrochemical deposition onto P(EDOT-NH2)-modified electrodes showed comparable electroactivity to pristine PEDOT coating. With P(EDOT-NH2) as an anchoring layer, PEDOT coating showed greatly enhanced adhesion. The modified coating could withstand extensive ultrasonication (1 hour) without significant cracking or delamination, whereas PEDOT typically delaminated after seconds of sonication. Therefore, this is an effective means to selectively modify microelectrodes with highly adherent and highly conductive polymer coatings as direct neural interfaces.
Collapse
Affiliation(s)
- Liangqi Ouyang
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - Bin Wei
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - Chin-chen Kuo
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - Sheevangi Pathak
- Department of Materials Science and Engineering, Pennsylvania State University, College Park, PA 16801, USA
| | - Brendan Farrell
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716, USA
| | - David C. Martin
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716, USA
| |
Collapse
|
30
|
Simon DT, Gabrielsson EO, Tybrandt K, Berggren M. Organic Bioelectronics: Bridging the Signaling Gap between Biology and Technology. Chem Rev 2016; 116:13009-13041. [PMID: 27367172 DOI: 10.1021/acs.chemrev.6b00146] [Citation(s) in RCA: 219] [Impact Index Per Article: 27.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The electronics surrounding us in our daily lives rely almost exclusively on electrons as the dominant charge carrier. In stark contrast, biological systems rarely use electrons but rather use ions and molecules of varying size. Due to the unique combination of both electronic and ionic/molecular conductivity in conducting and semiconducting organic polymers and small molecules, these materials have emerged in recent decades as excellent tools for translating signals between these two realms and, therefore, providing a means to effectively interface biology with conventional electronics-thus, the field of organic bioelectronics. Today, organic bioelectronics defines a generic platform with unprecedented biological recording and regulation tools and is maturing toward applications ranging from life sciences to the clinic. In this Review, we introduce the field, from its early breakthroughs to its current results and future challenges.
Collapse
Affiliation(s)
- Daniel T Simon
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University , 60174 Norrköping, Sweden
| | - Erik O Gabrielsson
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University , 60174 Norrköping, Sweden
| | - Klas Tybrandt
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University , 60174 Norrköping, Sweden.,Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zürich , 8092 Zürich, Switzerland
| | - Magnus Berggren
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University , 60174 Norrköping, Sweden
| |
Collapse
|
31
|
Alves-Sampaio A, García-Rama C, Collazos-Castro JE. Biofunctionalized PEDOT-coated microfibers for the treatment of spinal cord injury. Biomaterials 2016; 89:98-113. [DOI: 10.1016/j.biomaterials.2016.02.037] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2015] [Revised: 02/11/2016] [Accepted: 02/23/2016] [Indexed: 12/26/2022]
|
32
|
Martin DC, Malliaras GG. Interfacing Electronic and Ionic Charge Transport in Bioelectronics. ChemElectroChem 2016. [DOI: 10.1002/celc.201500555] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- David C. Martin
- Materials Science and Engineering and Biomedical Engineering The University of Delaware Newark DE 19716 USA
| | - George G. Malliaras
- Department of Bioelectronics École des Mines de Saint-Étienne Gardanne France
| |
Collapse
|
33
|
Strakosas X, Wei B, Martin DC, Owens RM. Biofunctionalization of polydioxythiophene derivatives for biomedical applications. J Mater Chem B 2016; 4:4952-4968. [DOI: 10.1039/c6tb00852f] [Citation(s) in RCA: 64] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
It is becoming clear that development of biomedical devices relies on engineering of the interface between the device and the biological component. Improved performance for these sensors and devices can be achieved through biofunctionalization. In this review we focus on highlighting the biofunctionalization of polydioxythiophene sensors.
Collapse
Affiliation(s)
| | - Bin Wei
- Materials Science and Engineering
- University of Delaware
- Newark
- US
| | - David C. Martin
- Materials Science and Engineering
- University of Delaware
- Newark
- US
| | | |
Collapse
|
34
|
Green R, Abidian MR. Conducting Polymers for Neural Prosthetic and Neural Interface Applications. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2015; 27:7620-37. [PMID: 26414302 PMCID: PMC4681501 DOI: 10.1002/adma.201501810] [Citation(s) in RCA: 193] [Impact Index Per Article: 21.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2015] [Revised: 06/11/2015] [Indexed: 05/20/2023]
Abstract
Neural-interfacing devices are an artificial mechanism for restoring or supplementing the function of the nervous system, lost as a result of injury or disease. Conducting polymers (CPs) are gaining significant attention due to their capacity to meet the performance criteria of a number of neuronal therapies including recording and stimulating neural activity, the regeneration of neural tissue and the delivery of bioactive molecules for mediating device-tissue interactions. CPs form a flexible platform technology that enables the development of tailored materials for a range of neuronal diagnostic and treatment therapies. In this review, the application of CPs for neural prostheses and other neural interfacing devices is discussed, with a specific focus on neural recording, neural stimulation, neural regeneration, and therapeutic drug delivery.
Collapse
Affiliation(s)
- Rylie Green
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, NSW 2052, Australia
| | - Mohammad Reza Abidian
- Biomedical Engineering Department, Materials Science & Engineering Department, Chemical Engineering Department, Materials Research Institute, Huck Institutes of the Life Sciences, Pennsylvania State University, University Park, PA 16802 (USA)
| |
Collapse
|
35
|
Thompson BC, Murray E, Wallace GG. Graphite Oxide to Graphene. Biomaterials to Bionics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2015; 27:7563-7582. [PMID: 25914294 DOI: 10.1002/adma.201500411] [Citation(s) in RCA: 84] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2015] [Revised: 03/04/2015] [Indexed: 06/04/2023]
Abstract
The advent of implantable biomaterials has revolutionized medical treatment, allowing the development of the fields of tissue engineering and medical bionic devices (e.g., cochlea implants to restore hearing, vagus nerve stimulators to control Parkinson's disease, and cardiac pace makers). Similarly, future materials developments are likely to continue to drive development in treatment of disease and disability, or even enhancing human potential. The material requirements for implantable devices are stringent. In all cases they must be nontoxic and provide appropriate mechanical integrity for the application at hand. In the case of scaffolds for tissue regeneration, biodegradability in an appropriate time frame may be required, and for medical bionics electronic conductivity is essential. The emergence of graphene and graphene-family composites has resulted in materials and structures highly relevant to the expansion of the biomaterials inventory available for implantable medical devices. The rich chemistries available are able to ensure properties uncovered in the nanodomain are conveyed into the world of macroscopic devices. Here, the inherent properties of graphene, along with how graphene or structures containing it interface with living cells and the effect of electrical stimulation on nerves and cells, are reviewed.
Collapse
Affiliation(s)
- Brianna C Thompson
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 639798, Singapore
| | - Eoin Murray
- Institute for Sports Research, Nanyang Technological University, 639798, Singapore
| | - Gordon G Wallace
- Intelligent Polymer Research Institute, ARC Center of Excellence for Electromaterials Science, University of Wollongong, 2500, Australia
| |
Collapse
|
36
|
Stavrinidou E, Gabrielsson R, Gomez E, Crispin X, Nilsson O, Simon DT, Berggren M. Electronic plants. SCIENCE ADVANCES 2015; 1:e1501136. [PMID: 26702448 PMCID: PMC4681328 DOI: 10.1126/sciadv.1501136] [Citation(s) in RCA: 106] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Accepted: 10/07/2015] [Indexed: 05/20/2023]
Abstract
The roots, stems, leaves, and vascular circuitry of higher plants are responsible for conveying the chemical signals that regulate growth and functions. From a certain perspective, these features are analogous to the contacts, interconnections, devices, and wires of discrete and integrated electronic circuits. Although many attempts have been made to augment plant function with electroactive materials, plants' "circuitry" has never been directly merged with electronics. We report analog and digital organic electronic circuits and devices manufactured in living plants. The four key components of a circuit have been achieved using the xylem, leaves, veins, and signals of the plant as the template and integral part of the circuit elements and functions. With integrated and distributed electronics in plants, one can envisage a range of applications including precision recording and regulation of physiology, energy harvesting from photosynthesis, and alternatives to genetic modification for plant optimization.
Collapse
Affiliation(s)
- Eleni Stavrinidou
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, SE-601 74 Norrköping, Sweden
| | - Roger Gabrielsson
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, SE-601 74 Norrköping, Sweden
| | - Eliot Gomez
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, SE-601 74 Norrköping, Sweden
| | - Xavier Crispin
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, SE-601 74 Norrköping, Sweden
| | - Ove Nilsson
- Department of Forest Genetics and Plant Physiology, Swedish University of Agricultural Sciences, SE-901 87 Umeå, Sweden
| | - Daniel T. Simon
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, SE-601 74 Norrköping, Sweden
| | - Magnus Berggren
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, SE-601 74 Norrköping, Sweden
- Corresponding author. E-mail:
| |
Collapse
|
37
|
Guex AA, Vachicouras N, Hight AE, Brown MC, Lee DJ, Lacour SP. Conducting polymer electrodes for auditory brainstem implants. J Mater Chem B 2015; 3:5021-5027. [PMID: 26207184 PMCID: PMC4507441 DOI: 10.1039/c5tb00099h] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The auditory brainstem implant (ABI) restores hearing in patients with damaged auditory nerves. One of the main ideas to improve the efficacy of ABIs is to increase spatial specificity of stimulation, in order to minimize extra-auditory side-effects and to maximize the tonotopy of stimulation. This study reports on the development of a microfabricated conformable electrode array with small (100 μm diameter) electrode sites. The latter are coated with a conducting polymer, PEDOT:PSS, to offer high charge injection properties and to safely stimulate the auditory system with small stimulation sites. We report on the design and fabrication of the polymer implant, and characterize the coatings in physiological conditions in vitro and under mechanical deformation. We characterize the coating electrochemically and during bending tests. We present a proof of principle experiment where the auditory system is efficiently activated by the flexible polymeric interface in a rat model. These results demonstrate the potential of using conducting polymer coatings on small electrode sites for electrochemically safe and efficient stimulation of the central auditory system.
Collapse
Affiliation(s)
- Amélie A. Guex
- Center for Neuroprosthetics, Ecole Polytechnique Federale de Lausanne, Lausanne, Switzerland
| | - Nicolas Vachicouras
- Center for Neuroprosthetics, Ecole Polytechnique Federale de Lausanne, Lausanne, Switzerland
| | - Ariel E. Hight
- Eaton-Peabody Laboratories and Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, and Department of Otology and Laryngology, Harvard Medical School, Boston, Massachusetts
| | - M. Christian Brown
- Eaton-Peabody Laboratories and Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, and Department of Otology and Laryngology, Harvard Medical School, Boston, Massachusetts
| | - Daniel J. Lee
- Eaton-Peabody Laboratories and Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, and Department of Otology and Laryngology, Harvard Medical School, Boston, Massachusetts
| | - Stéphanie P. Lacour
- Center for Neuroprosthetics, Ecole Polytechnique Federale de Lausanne, Lausanne, Switzerland
| |
Collapse
|
38
|
Frost CM, Cederna PS, Martin DC, Shim BS, Urbanchek MG. Decellular biological scaffold polymerized with PEDOT for improving peripheral nerve interface charge transfer. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:422-5. [PMID: 25569986 DOI: 10.1109/embc.2014.6943618] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Regenerative peripheral nerve interfaces (RPNIs) are for signal transfer between peripheral nerves inside the body to controllers for motorized prosthetics external to the body. Within the residual limb of an amputee, surgical construction of a RPNI connects a remaining peripheral nerve and spare muscle. Nerve signals become concentrated within the RPNI. Currently metal electrodes implanted on the RPNI muscle transfer signals but scarring around metal electrodes progressively diminishes charge transfer. Engineered materials may benefit RPNI signal transfer across the neural interface if they lower the power and charge density of the biologically meaningful signals. Poly3,4-ethylenedioxythiophene (PEDOT) is known to mediate ionic potentials allowing excitation across a critical nerve gap. We hypothesize that the capacity of an interface material to conduct electron mediated current is significantly increased by polymerized coating of PEDOT. SIS was either used plain or after PEDOT coating by electrochemical polymerization. Muscle forces are a direct representation of stimulating current distribution within an RPNI. In situ muscle forces were measured for the same muscle by electrically stimulating: a) the muscle's innervating nerve, b) directly on the muscle, c) on plain SIS laid on the muscle, and d) on SIS polymerized with PEDOT laid on the muscle. Electro-chemically coating PEDOT on SIS resulted in a thin, flexible material. PEDOT coated SIS distributed electrical stimulation more efficiently than SIS alone. Conductive polymer containing biological material allowed ionic signal distribution within the RPNI like muscle at lower charge density.
Collapse
|
39
|
Ouyang L, Kuo CC, Farrell B, Pathak S, Wei B, Qu J, Martin DC. Poly[3,4-ethylene dioxythiophene (EDOT) -co- 1,3,5-tri[2-(3,4-ethylene dioxythienyl)]-benzene (EPh)] copolymers (PEDOT-co-EPh): optical, electrochemical and mechanical properties. J Mater Chem B 2015; 3:5010-5020. [PMID: 26413299 DOI: 10.1039/c5tb00053j] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
PEDOT-co-EPh copolymers with systematic variations in composition were prepared by electrochemical polymerization from mixed monomer solutions in acetonitrile. The EPh monomer is a trifunctional crosslinking agent with three EDOTs around a central benzene ring. With increasing EPh content, the color of the copolymers changed from blue to yellow to red due to decreased absorption in the near infrared (IR) spectrum and increased absorption in the visible spectrum. The surface morphology changed from rough and nanofibrillar to more smooth with rounded bumps. The electrical transport properties dramatically decreased with increasing EPh content, resulting in coatings that either substantially lowered the impedance of the electrode (at the lowest EPh content), leave the impedance nearly unchanged (near 1% EPh), or significantly increase the impedance (at 1% and above). The mechanical properties of the films were substantially improved with EPh content, with the 0.5% EPh films showing an estimated 5x improvement in modulus measured by AFM nanoindentation. The PEDOT-co-EPh copolymer films were all shown to be non-cytotoxic toward and promote the neurite outgrowth of PC12 cells. Given these results, we expect that the films of most interest for neural interface applications will be those with improved mechanical properties that maintain the improved charge transport performance (with 1% EPh and below).
Collapse
|