1
|
Zeng Q, Xing C, Xu Z, Liu Q, Yang L, Yang H, Zhang Y, Peng Z. Fast Electrodeposition of MXene/PDA Composites for High‐Performance Bioelectronic Interfaces: An In Vitro Evaluation. ADVANCED FUNCTIONAL MATERIALS 2024; 34. [DOI: 10.1002/adfm.202312770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Indexed: 11/28/2024]
Abstract
AbstractBioelectrode is critical to many biomedical researches. However, traditional materials (typically noble metals) and manufacturing techniques limit the large‐scale production of bioelectrodes. Herein, a fast electrochemical approach is proposed to deposit versatile MXene/polydopamine (PDA) composites on a metalized substrate. PDA coating can improve the adhesion between MXene and the substrate, while MXene provides rough surfaces with unique micro/nanostructure and outstanding electrical/optical/thermal performance. The impedance of the as‐prepared bioelectrode at 1 kHz is down to 8.48 Ω cm2. The corresponding cathodic charge storage capacity (CSCc) and charge injection capacity (CIC) are up to ≈250 and 6.59 mC cm−2 respectively, much superior to that of bare Pt and other conventional material‐based electrodes. The MXene/PDA composites also demonstrate robust stability under continuous electrostimulation for 1 × 108 pulse cycles and 1000 CV cycles. Moreover, MXene/PDA composites show a high and rapid photothermal response. Photoelectrochemical activity is also observed with high photocurrent, ≈40 folds larger than that of bare Pt. The utility of this new electrode in ascorbic acid sensing is demonstrated. Excellent biocompatibility is verified via neuron adhesion test and viability assay.
Collapse
Affiliation(s)
- Qi Zeng
- State Key Laboratory of Radio Frequency Heterogeneous Integration School of Physics and Optoelectronic Engineering Shenzhen University Shenzhen 518061 China
| | - Chenyang Xing
- State Key Laboratory of Radio Frequency Heterogeneous Integration School of Physics and Optoelectronic Engineering Shenzhen University Shenzhen 518061 China
| | - Zhen Xu
- Shenzhen Institute of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
| | - Qing Liu
- Shenzhen Institute of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
| | - Liangtao Yang
- Shenzhen Institute of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
| | - Hui Yang
- Shenzhen Institute of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
| | - Yi Zhang
- Shenzhen Institute of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
| | - Zhengchun Peng
- State Key Laboratory of Radio Frequency Heterogeneous Integration School of Physics and Optoelectronic Engineering Shenzhen University Shenzhen 518061 China
| |
Collapse
|
2
|
Rodilla BL, Arché-Núñez A, Ruiz-Gómez S, Domínguez-Bajo A, Fernández-González C, Guillén-Colomer C, González-Mayorga A, Rodríguez-Díez N, Camarero J, Miranda R, López-Dolado E, Ocón P, Serrano MC, Pérez L, González MT. Flexible metallic core-shell nanostructured electrodes for neural interfacing. Sci Rep 2024; 14:3729. [PMID: 38355737 PMCID: PMC10866994 DOI: 10.1038/s41598-024-53719-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 02/04/2024] [Indexed: 02/16/2024] Open
Abstract
Electrodes with nanostructured surface have emerged as promising low-impedance neural interfaces that can avoid the charge-injection restrictions typically associated to microelectrodes. In this work, we propose a novel approximation, based on a two-step template assisted electrodeposition technique, to obtain flexible nanostructured electrodes coated with core-shell Ni-Au vertical nanowires. These nanowires benefit from biocompatibility of the Au shell exposed to the environment and the mechanical properties of Ni that allow for nanowires longer and more homogeneous in length than their only-Au counterparts. The nanostructured electrodes show impedance values, measured by electrochemical impedance spectroscopy (EIS), at least 9 times lower than those of flat reference electrodes. This ratio is in good accordance with the increased effective surface area determined both from SEM images and cyclic voltammetry measurements, evidencing that only Au is exposed to the medium. The observed EIS profile evolution of Ni-Au electrodes over 7 days were very close to those of Au electrodes and differently from Ni ones. Finally, the morphology, viability and neuronal differentiation of rat embryonic cortical cells cultured on Ni-Au NW electrodes were found to be similar to those on control (glass) substrates and Au NW electrodes, accompanied by a lower glial cell differentiation. This positive in-vitro neural cell behavior encourages further investigation to explore the tissue responses that the implantation of these nanostructured electrodes might elicit in healthy (damaged) neural tissues in vivo, with special emphasis on eventual tissue encapsulation.
Collapse
Affiliation(s)
- Beatriz L Rodilla
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
- Departamento de Física de Materiales, Universidad Complutense de Madrid, Plaza de las Ciencias S/N, 28040, Madrid, Spain
| | - Ana Arché-Núñez
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
| | - Sandra Ruiz-Gómez
- Max Planck Institute for Chemical Physics of Solids, Dresden, Germany
| | - Ana Domínguez-Bajo
- Instituto de Ciencia de Materiales de Madrid (ICMM), CSIC, Calle Sor Juana Inés de la Cruz 3, 28049, Madrid, Spain
- Animal Molecular and Cellular Biology group (AMCB), Louvain Institute of Biomolecular Science and Technology (LIBST), Université catholique de Louvain, Place Croix du Sud 5, 1348 , Louvain la Neuve, Belgium
| | | | | | | | | | - Julio Camarero
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
- Department de Física de la Materia Condensada and Instituto "Nicolás Cabrera", Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - Rodolfo Miranda
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
- Department de Física de la Materia Condensada and Instituto "Nicolás Cabrera", Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - Elisa López-Dolado
- Hospital Nacional de Parapléjicos, SESCAM, Finca la Peraleda S/N, 45071, Toledo, Spain
- Design and development of Biomaterials for Neural Regeneration, HNP-SESCAM, Associated Unit With CSIC Through ICMM, Finca La Peraleda S/N, 45071, Toledo, Spain
| | - Pilar Ocón
- Departamento de Química Física Aplicada, Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - María C Serrano
- Instituto de Ciencia de Materiales de Madrid (ICMM), CSIC, Calle Sor Juana Inés de la Cruz 3, 28049, Madrid, Spain
| | - Lucas Pérez
- Fundación IMDEA Nanociencia, Calle Faraday 9, 28049, Madrid, Spain
- Departamento de Física de Materiales, Universidad Complutense de Madrid, Plaza de las Ciencias S/N, 28040, Madrid, Spain
| | | |
Collapse
|
3
|
Kim YH, Koo H, Kim MS, Jung SD. Fabrication of a photo-crosslinkable fluoropolymer-passivated flexible neural probe and acute recording and stimulation performances in vivo. BIOMATERIALS ADVANCES 2023; 154:213629. [PMID: 37742557 DOI: 10.1016/j.bioadv.2023.213629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 08/25/2023] [Accepted: 09/16/2023] [Indexed: 09/26/2023]
Abstract
Herein, we fabricated fluorine-containing, polymer-based, flexible neural probes with fluorinated ethylene propylene (FEP) films as the substrates and photo-crosslinkable fluoropolymers as the passivation material. For fabrication, metal-free Au layer formation on the FEP film, the simultaneous photo-adhesion and photo-patterning technique, and the pulsed-laser scanning probe shaping technique were combined, followed by Au electrode surface modification. The resultant probes achieved a charge injection limit equal to 5.18 mC cm-2 by implementing iridium oxide-modified nanoporous Au (IrOx/NPG) structures. We performed simultaneous in vivo micro-stimulations of the Schaffer collateral fibres and recorded the evoked field excitatory postsynaptic potentials (fEPSPs) in the stratum radiatum layer of the hippocampal Cornu Ammonis 1 region using a single probe. Inducing the fEPSP at very low charge per pulse settings (3.2-3.6 nC/pulse) indicates the efficient charge injection capability of the IrOx/NPG electrode, thereby enabling safe, prolonged, and thrifty micro-stimulations. Furthermore, the single probe-induced and recorded long-term potentiation persisted for periods longer than 60 min following theta-burst stimulation. The materials used in this study are all biocompatible and chemically robust. The fabricated neural probes can be applied in chronic clinical trials in vivo.
Collapse
Affiliation(s)
- Yong Hee Kim
- Cybre Brain Research Section, Electronics and Telecommunications Research Institute, 218 Gajeong-ro, Yuseong-gu, Daejeon 305-700, Republic of Korea
| | - Ho Koo
- Department of Neuroscience, Cell Biology, and Anatomy, University of Texas Medical Branch, Galveston, TX, United States
| | - Min Sun Kim
- Department of Physiology, Wonkwang University School of Medicine, 895 Munwang-ro, Iksan 570-711, Jeollabuk-do, Republic of Korea
| | - Sang-Don Jung
- Cybre Brain Research Section, Electronics and Telecommunications Research Institute, 218 Gajeong-ro, Yuseong-gu, Daejeon 305-700, Republic of Korea.
| |
Collapse
|
4
|
Ziai Y, Zargarian SS, Rinoldi C, Nakielski P, Sola A, Lanzi M, Truong YB, Pierini F. Conducting polymer-based nanostructured materials for brain-machine interfaces. WILEY INTERDISCIPLINARY REVIEWS. NANOMEDICINE AND NANOBIOTECHNOLOGY 2023; 15:e1895. [PMID: 37141863 DOI: 10.1002/wnan.1895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 03/14/2023] [Accepted: 04/05/2023] [Indexed: 05/06/2023]
Abstract
As scientists discovered that raw neurological signals could translate into bioelectric information, brain-machine interfaces (BMI) for experimental and clinical studies have experienced massive growth. Developing suitable materials for bioelectronic devices to be used for real-time recording and data digitalizing has three important necessitates which should be covered. Biocompatibility, electrical conductivity, and having mechanical properties similar to soft brain tissue to decrease mechanical mismatch should be adopted for all materials. In this review, inorganic nanoparticles and intrinsically conducting polymers are discussed to impart electrical conductivity to systems, where soft materials such as hydrogels can offer reliable mechanical properties and a biocompatible substrate. Interpenetrating hydrogel networks offer more mechanical stability and provide a path for incorporating polymers with desired properties into one strong network. Promising fabrication methods, like electrospinning and additive manufacturing, allow scientists to customize designs for each application and reach the maximum potential for the system. In the near future, it is desired to fabricate biohybrid conducting polymer-based interfaces loaded with cells, giving the opportunity for simultaneous stimulation and regeneration. Developing multi-modal BMIs, Using artificial intelligence and machine learning to design advanced materials are among the future goals for this field. This article is categorized under: Therapeutic Approaches and Drug Discovery > Nanomedicine for Neurological Disease.
Collapse
Affiliation(s)
- Yasamin Ziai
- Department of Biosystems and Soft Matter, Institute of Fundamental Technological Research, Polish Academy of Sciences, Warsaw, Poland
| | - Seyed Shahrooz Zargarian
- Department of Biosystems and Soft Matter, Institute of Fundamental Technological Research, Polish Academy of Sciences, Warsaw, Poland
| | - Chiara Rinoldi
- Department of Biosystems and Soft Matter, Institute of Fundamental Technological Research, Polish Academy of Sciences, Warsaw, Poland
| | - Paweł Nakielski
- Department of Biosystems and Soft Matter, Institute of Fundamental Technological Research, Polish Academy of Sciences, Warsaw, Poland
| | - Antonella Sola
- Commonwealth Scientific and Industrial Research Organisation (CSIRO), Manufacturing Business Unit, Clayton, Victoria, Australia
| | - Massimiliano Lanzi
- Department of Industrial Chemistry "Toso Montanari", University of Bologna, Bologna, Italy
| | - Yen Bach Truong
- Commonwealth Scientific and Industrial Research Organisation (CSIRO), Manufacturing Business Unit, Clayton, Victoria, Australia
| | - Filippo Pierini
- Department of Biosystems and Soft Matter, Institute of Fundamental Technological Research, Polish Academy of Sciences, Warsaw, Poland
| |
Collapse
|
5
|
Zare I, Yaraki MT, Speranza G, Najafabadi AH, Haghighi AS, Nik AB, Manshian BB, Saraiva C, Soenen SJ, Kogan MJ, Lee JW, Apollo NV, Bernardino L, Araya E, Mayer D, Mao G, Hamblin MR. Gold nanostructures: synthesis, properties, and neurological applications. Chem Soc Rev 2022; 51:2601-2680. [PMID: 35234776 DOI: 10.1039/d1cs01111a] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Recent advances in technology are expected to increase our current understanding of neuroscience. Nanotechnology and nanomaterials can alter and control neural functionality in both in vitro and in vivo experimental setups. The intersection between neuroscience and nanoscience may generate long-term neural interfaces adapted at the molecular level. Owing to their intrinsic physicochemical characteristics, gold nanostructures (GNSs) have received much attention in neuroscience, especially for combined diagnostic and therapeutic (theragnostic) purposes. GNSs have been successfully employed to stimulate and monitor neurophysiological signals. Hence, GNSs could provide a promising solution for the regeneration and recovery of neural tissue, novel neuroprotective strategies, and integrated implantable materials. This review covers the broad range of neurological applications of GNS-based materials to improve clinical diagnosis and therapy. Sub-topics include neurotoxicity, targeted delivery of therapeutics to the central nervous system (CNS), neurochemical sensing, neuromodulation, neuroimaging, neurotherapy, tissue engineering, and neural regeneration. It focuses on core concepts of GNSs in neurology, to circumvent the limitations and significant obstacles of innovative approaches in neurobiology and neurochemistry, including theragnostics. We will discuss recent advances in the use of GNSs to overcome current bottlenecks and tackle technical and conceptual challenges.
Collapse
Affiliation(s)
- Iman Zare
- Research and Development Department, Sina Medical Biochemistry Technologies Co. Ltd., Shiraz 7178795844, Iran
| | | | - Giorgio Speranza
- CMM - FBK, v. Sommarive 18, 38123 Trento, Italy.,IFN - CNR, CSMFO Lab., via alla Cascata 56/C Povo, 38123 Trento, Italy.,Department of Industrial Engineering, University of Trento, v. Sommarive 9, 38123 Trento, Italy
| | - Alireza Hassani Najafabadi
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, CA 90064, USA.,Department of Pharmaceutical Sciences, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Alireza Shourangiz Haghighi
- Department of Mechanical Engineering, Shiraz University of Technology, Modarres Boulevard, 13876-71557, Shiraz, Iran
| | - Amirala Bakhshian Nik
- Department of Biomedical Engineering, Florida International University, Miami, FL 33174, USA
| | - Bella B Manshian
- Translational Cell and Tissue Research Unit, Department of Imaging and Pathology, KU Leuven, Herestraat 49, B3000 Leuven, Belgium
| | - Cláudia Saraiva
- Luxembourg Centre for Systems Biomedicine (LCSB), University of Luxembourg, 7 Avenue des Hauts-Fourneaux, 4362 Esch-sur-Alzette, Luxembourg.,Health Sciences Research Centre (CICS-UBI), University of Beira Interior, Rua Marques d'Avila e Bolama, 6201-001 Covilha, Portugal
| | - Stefaan J Soenen
- NanoHealth and Optical Imaging Group, Department of Imaging and Pathology, KU Leuven, Herestraat 49, B3000 Leuven, Belgium
| | - Marcelo J Kogan
- Advanced Center for Chronic Diseases (ACCDiS), Facultad de Ciencias Químicas y Farmacéuticas, Departamento de Química Farmacológica y Toxicológica, Universidad de Chile, 8380492 Santiago, Chile
| | - Jee Woong Lee
- Department of Medical Sciences, Clinical Neurophysiology, Uppsala University, Uppsala, SE-751 23, Sweden
| | - Nicholas V Apollo
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA.,School of Physics, University of Melbourne, Parkville, Victoria 3010, Australia
| | - Liliana Bernardino
- Health Sciences Research Centre (CICS-UBI), University of Beira Interior, Rua Marques d'Avila e Bolama, 6201-001 Covilha, Portugal
| | - Eyleen Araya
- Departamento de Ciencias Quimicas, Facultad de Ciencias Exactas, Universidad Andres Bello, Av. Republica 275, Santiago, Chile
| | - Dirk Mayer
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Germany
| | - Guangzhao Mao
- School of Chemical Engineering, University of New South Wales (UNSW Sydney), Sydney, NSW 2052, Australia
| | - Michael R Hamblin
- Laser Research Center, University of Johannesburg, Doorfontein 2028, South Africa.
| |
Collapse
|
6
|
Mobini S, González MU, Caballero-Calero O, Patrick EE, Martín-González M, García-Martín JM. Effects of nanostructuration on the electrochemical performance of metallic bioelectrodes. NANOSCALE 2022; 14:3179-3190. [PMID: 35142756 DOI: 10.1039/d1nr06280h] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The use of metallic nanostructures in the fabrication of bioelectrodes (e.g., neural implants) is gaining attention nowadays. Nanostructures provide increased surface area that might benefit the performance of bioelectrodes. However, there is a need for comprehensive studies that assess electrochemical performance of nanostructured surfaces in physiological and relevant working conditions. Here, we introduce a versatile scalable fabrication method based on magnetron sputtering to develop analogous metallic nanocolumnar structures (NCs) and thin films (TFs) from Ti, Au, and Pt. We show that NCs contribute significantly to reduce the impedance of metallic surfaces. Charge storage capacity of Pt NCs is remarkably higher than that of Pt TFs and that of the other metals in both morphologies. Circuit simulations of the electrode/electrolyte interface show that the signal delivered in voltage-controlled systems is less filtered when nanocolumns are used. In a current-controlled system, simulation shows that NCs provide safer stimulation conditions compared to TFs. We have assessed the durability of NCs and TFs for potential use in vivo by reactive accelerated aging test, mimicking one-year in vivo implantation. Although each metal/morphology reveals a unique response to aging, NCs show overall more stable electrochemical properties compared to TFs in spite of their porous structure.
Collapse
Affiliation(s)
- Sahba Mobini
- Instituto de Micro y Nanotecnología, IMN-CNM, CSIC (CEI UAM+CSIC), Isaac Newton 8, E-28760, Tres Cantos, Madrid, Spain.
| | - María Ujué González
- Instituto de Micro y Nanotecnología, IMN-CNM, CSIC (CEI UAM+CSIC), Isaac Newton 8, E-28760, Tres Cantos, Madrid, Spain.
| | - Olga Caballero-Calero
- Instituto de Micro y Nanotecnología, IMN-CNM, CSIC (CEI UAM+CSIC), Isaac Newton 8, E-28760, Tres Cantos, Madrid, Spain.
| | - Erin E Patrick
- Department of Electrical and Computer Engineering, University of Florida, Center Drive 968, Gainesville, FL 32603, USA
| | - Marisol Martín-González
- Instituto de Micro y Nanotecnología, IMN-CNM, CSIC (CEI UAM+CSIC), Isaac Newton 8, E-28760, Tres Cantos, Madrid, Spain.
| | - José Miguel García-Martín
- Instituto de Micro y Nanotecnología, IMN-CNM, CSIC (CEI UAM+CSIC), Isaac Newton 8, E-28760, Tres Cantos, Madrid, Spain.
| |
Collapse
|
7
|
Domínguez-Bajo A, Rosa JM, González-Mayorga A, Rodilla BL, Arché-Núñez A, Benayas E, Ocón P, Pérez L, Camarero J, Miranda R, González MT, Aguilar J, López-Dolado E, Serrano MC. Nanostructured gold electrodes promote neural maturation and network connectivity. Biomaterials 2021; 279:121186. [PMID: 34700221 DOI: 10.1016/j.biomaterials.2021.121186] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Revised: 10/05/2021] [Accepted: 10/12/2021] [Indexed: 12/22/2022]
Abstract
Progress in the clinical application of recording and stimulation devices for neural diseases is still limited, mainly because of suboptimal material engineering and unfavorable interactions with biological entities. Nanotechnology is providing upgraded designs of materials to better mimic the native extracellular environment and attain more intimate contacts with individual neurons, besides allowing for the miniaturization of the electrodes. However, little progress has been done to date on the understanding of the biological impact that such neural interfaces have on neural network maturation and functionality. In this work, we elucidate the effect of a gold (Au) highly ordered nanostructure on the morphological and functional interactions with neural cells and tissues. Alumina-templated Au nanostructured electrodes composed of parallel nanowires of 160 nm in diameter and 1.2 μm in length (Au-NWs), with 320 nm of pitch, are designed and characterized. Equivalent non-structured Au electrodes (Au-Flat) are used for comparison. By using diverse techniques in in vitro cell cultures including live calcium imaging, we found that Au-NWs interfaced with primary neural cortical cells for up to 14 days allow neural networks growth and increase spontaneous activity and ability of neuronal synchronization, thus indicating that nanostructured features favor neuronal network. The enhancement in the number of glial cells found is hypothesized to be behind these beneficial functional effects. The in vivo effect of the implantation of these nanostructured electrodes and its potential relevance for future clinical applicability has been explored in an experimental model of rat spinal cord injury. Subacute responses to implanted Au-NWs show no overt reactive or toxic biological reactions besides those triggered by the injury itself. These results highlight the translational potential of Au-NWs electrodes for in vivo applications as neural interfaces in contact with central nervous tissues including the injured spinal cord.
Collapse
Affiliation(s)
- Ana Domínguez-Bajo
- Instituto de Ciencia de Materiales de Madrid (ICMM), CSIC, Calle Sor Juana Inés de la Cruz 3, 28049, Madrid, Spain
| | - Juliana M Rosa
- Hospital Nacional de Parapléjicos, SESCAM, Finca La Peraleda s/n, 45071, Toledo, Spain
| | | | - Beatriz L Rodilla
- Instituto Madrileño de Estudios Avanzados (IMDEA Nanociencia), Calle Faraday 9, 28049, Madrid, Spain; Departamento de Física de Materiales, Universidad Complutense de Madrid, Plaza de las Ciencias s/n, 28040, Madrid, Spain
| | - Ana Arché-Núñez
- Instituto Madrileño de Estudios Avanzados (IMDEA Nanociencia), Calle Faraday 9, 28049, Madrid, Spain
| | - Esther Benayas
- Instituto de Ciencia de Materiales de Madrid (ICMM), CSIC, Calle Sor Juana Inés de la Cruz 3, 28049, Madrid, Spain
| | - Pilar Ocón
- Departamento de Química Física Aplicada, Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - Lucas Pérez
- Instituto Madrileño de Estudios Avanzados (IMDEA Nanociencia), Calle Faraday 9, 28049, Madrid, Spain; Departamento de Física de Materiales, Universidad Complutense de Madrid, Plaza de las Ciencias s/n, 28040, Madrid, Spain
| | - Julio Camarero
- Instituto Madrileño de Estudios Avanzados (IMDEA Nanociencia), Calle Faraday 9, 28049, Madrid, Spain; Instituto "Nicolás Cabrera" and Condensed Matter Physics Center (IFIMAC), Departamento de Física de la Materia Condensada, Universidad Autonoma de Madrid, Madrid, 28049, Spain
| | - Rodolfo Miranda
- Instituto Madrileño de Estudios Avanzados (IMDEA Nanociencia), Calle Faraday 9, 28049, Madrid, Spain; Instituto "Nicolás Cabrera" and Condensed Matter Physics Center (IFIMAC), Departamento de Física de la Materia Condensada, Universidad Autonoma de Madrid, Madrid, 28049, Spain
| | - M Teresa González
- Instituto Madrileño de Estudios Avanzados (IMDEA Nanociencia), Calle Faraday 9, 28049, Madrid, Spain
| | - Juan Aguilar
- Hospital Nacional de Parapléjicos, SESCAM, Finca La Peraleda s/n, 45071, Toledo, Spain; Research Unit of "Design and development of biomaterials for neural regeneration", Hospital Nacional de Parapléjicos, Joint Research Unit with CSIC, Finca La Peraleda s/n, 45071, Toledo, Spain
| | - Elisa López-Dolado
- Hospital Nacional de Parapléjicos, SESCAM, Finca La Peraleda s/n, 45071, Toledo, Spain; Research Unit of "Design and development of biomaterials for neural regeneration", Hospital Nacional de Parapléjicos, Joint Research Unit with CSIC, Finca La Peraleda s/n, 45071, Toledo, Spain
| | - María C Serrano
- Instituto de Ciencia de Materiales de Madrid (ICMM), CSIC, Calle Sor Juana Inés de la Cruz 3, 28049, Madrid, Spain.
| |
Collapse
|
8
|
Wang Y, Graham ES, Unsworth CP. Superior galvanostatic electrochemical deposition of platinum nanograss provides high performance planar microelectrodes for in vitroneural recording. J Neural Eng 2021; 18. [PMID: 34371484 DOI: 10.1088/1741-2552/ac1bc1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Accepted: 08/09/2021] [Indexed: 11/11/2022]
Abstract
Objective.Platinum nanograss (Ptng) has been demonstrated as an excellent coating to increase the electrode roughness and reduce the impedance of microelectrodes for neural recording. However, the optimisation of the original potentiostatic electrochemical deposition (PSED) method has been performed by the original group only and noin vitrovalidation of functionality was reported.Approach.This study firstly reinvestigates the use of the PSED method for Ptng coating at different charge densities which highlights non-uniformities in the edges of the microelectrodes for increasing deposition charge densities, leading to a decreased impedance which is in fact an artefact. We then introduce a novel Ptng fabrication method of galvanostatic electrochemical deposition (GSED).Main results.We demonstrate that the GSED deposition method also significantly reduces the electrode impedance, raises the charge storage capacity and provides a significantly more planar electrode surface in comparison to the PSED method with negligible edge effects. In addition, we demonstrate how high-quality neural recordings were performed, for the first time, using the Ptng GSED deposition microelectrodes from human hNT neurons and how spiking and bursting were observed.Significance.Thus, the GSED Ptng deposition method presented here provides an alternative method of microelectrode fabrication for neural applications with excellent impedance and planarity of surface.
Collapse
Affiliation(s)
- Yi Wang
- Department of Engineering Science, University of Auckland, Auckland, New Zealand and the MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington, New Zealand
| | - E Scott Graham
- Department of Molecular Medicine and Pathology, School of Medical Sciences, and Centre for Brain Research, University of Auckland, Auckland, New Zealand
| | - Charles P Unsworth
- Department of Engineering Science, University of Auckland, Auckland, New Zealand and the MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington, New Zealand
| |
Collapse
|
9
|
Liang Y, Offenhäusser A, Ingebrandt S, Mayer D. PEDOT:PSS-Based Bioelectronic Devices for Recording and Modulation of Electrophysiological and Biochemical Cell Signals. Adv Healthc Mater 2021; 10:e2100061. [PMID: 33970552 PMCID: PMC11468774 DOI: 10.1002/adhm.202100061] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 03/31/2021] [Indexed: 12/16/2022]
Abstract
To understand the physiology and pathology of electrogenic cells and the corresponding tissue in their full complexity, the quantitative investigation of the transmission of ions as well as the release of chemical signals is important. Organic (semi-) conducting materials and in particular organic electrochemical transistor are gaining in importance for the investigation of electrophysiological and recently biochemical signals due to their synthetic nature and thus chemical diversity and modifiability, their biocompatible and compliant properties, as well as their mixed electronic and ionic conductivity featuring ion-to-electron conversion. Here, the aim is to summarize recent progress on the development of bioelectronic devices utilizing polymer polyethylenedioxythiophene: poly(styrene sulfonate) (PEDOT:PSS) to interface electronics and biological matter including microelectrode arrays, neural cuff electrodes, organic electrochemical transistors, PEDOT:PSS-based biosensors, and organic electronic ion pumps. Finally, progress in the material development is summarized for the improvement of polymer conductivity, stretchability, higher transistor transconductance, or to extend their field of application such as cation sensing or metabolite recognition. This survey of recent trends in PEDOT:PSS electrophysiological sensors highlights the potential of this multifunctional material to revolve current technology and to enable long-lasting, multichannel polymer probes for simultaneous recordings of electrophysiological and biochemical signals from electrogenic cells.
Collapse
Affiliation(s)
- Yuanying Liang
- Institute of Polymer Optoelectronic Materials and DevicesState Key Laboratory of Luminescent Materials and DevicesSouth China University of TechnologyGuangzhouGuangdong510640China
| | - Andreas Offenhäusser
- Institute of Biological Information ProcessingBioelectronics IBI‐3Forschungszentrum JülichJülich52425Germany
| | - Sven Ingebrandt
- Faculty of Electrical Engineering and Information TechnologyInstitute of Materials in Electrical Engineering 1RWTH Aachen UniversityAachen52074Germany
| | - Dirk Mayer
- Institute of Biological Information ProcessingBioelectronics IBI‐3Forschungszentrum JülichJülich52425Germany
| |
Collapse
|
10
|
Bae JH, Kim K, Han D, Chung TD. Ultra Compact Nanoporous Platinum Coating Improves Neural Recording. ELECTROANAL 2021. [DOI: 10.1002/elan.202060519] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Je Hyun Bae
- Graduate School of Analytical Science and Technology Chungnam National University 34134 Daejeon Republic of Korea
| | - Kayeon Kim
- Helsinki Institute of Life Sciences Neuroscience Center University of Helsinki PO Box 63 FI-00271 Helsinki Finland
| | - Donghoon Han
- Department of Chemistry The Catholic University of Korea 14662 Bucheon Gyeonggi-do Republic of Korea
| | - Taek Dong Chung
- Department of Chemistry Seoul National University 08826 Seoul Republic of Korea
- Electrochemistry Laboratory Advanced Institutes of Convergence Technology 16229 Suwon Gyeonggi-do Republic of Korea
| |
Collapse
|
11
|
Alvarez NT, Buschbeck E, Miller S, Le AD, Gupta VK, Ruhunage C, Vilinsky I, Ma Y. Carbon Nanotube Fibers for Neural Recording and Stimulation. ACS APPLIED BIO MATERIALS 2020; 3:6478-6487. [PMID: 35021779 DOI: 10.1021/acsabm.0c00861] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Recordings and stimulations of neuronal electrical activity are topics of great interest in neuroscience. Many recording techniques, and even treatment of neurological disorders, can benefit from a microelectrode that is flexible, chemically inert, and electrically conducting and preferentially transfers electrons via capacitive charge injection. Commercial electrodes that currently exist and other electrodes that are being tested with the purpose of facilitating and improving the electron transport between solid materials and biological tissues still have some limitations. This paper discusses carbon nanotube (CNT)-based microelectrodes to record and stimulate neurons and compares their electron transport capabilities to noble metals such as Au and Ag. The recording ability of electrodes is tested through electroretinography on Sarcophaga bullata fly eyes by using Au and Ag wires and CNT fibers as electrodes. Stimulation is demonstrated through the implantation of Au wire and CNT fibers into the antennas of the Madagascar hissing cockroach (Gromphadorhina portentosa) to control their locomotion. Our results demonstrate that a particular property of the CNT fiber is its high rate of electron transfer, leading to an order of magnitude lower impedance compared to Au and Ag and an impressive 15.09 charge injection capacity. We also established that this carbon nanomaterial assembly performs well for in vivo electrophysiology, rendering it a promising prospect for neurophysiological applications.
Collapse
Affiliation(s)
- Noe T Alvarez
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Elke Buschbeck
- Department of Biology, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Sydney Miller
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Anh Duc Le
- Department of Biology, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Vandna K Gupta
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Chethani Ruhunage
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Ilya Vilinsky
- Department of Biology, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Yishan Ma
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| |
Collapse
|
12
|
Won SM, Song E, Reeder JT, Rogers JA. Emerging Modalities and Implantable Technologies for Neuromodulation. Cell 2020; 181:115-135. [DOI: 10.1016/j.cell.2020.02.054] [Citation(s) in RCA: 63] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Revised: 02/23/2020] [Accepted: 02/25/2020] [Indexed: 02/08/2023]
|
13
|
Lee D, Moon HC, Tran BT, Kwon DH, Kim YH, Jung SD, Joo JH, Park YS. Characterization of Tetrodes Coated with Au Nanoparticles (AuNPs) and PEDOT and Their Application to Thalamic Neural Signal Detection in vivo. Exp Neurobiol 2019; 27:593-604. [PMID: 30636908 PMCID: PMC6318560 DOI: 10.5607/en.2018.27.6.593] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Revised: 11/12/2018] [Accepted: 11/16/2018] [Indexed: 11/27/2022] Open
Abstract
Tetrodes, consisting of four twisted micro-wires can simultaneously record the number of neurons in the brain. To improve the quality of neuronal activity detection, the tetrode tips should be modified to increase the surface area and lower the impedance properties. In this study, tetrode tips were modified by the electrodeposition of Au nanoparticles (AuNPs) and dextran (Dex) doped poly (3,4-ethylenedioxythiophene) (PEDOT). The electrochemical properties were measured using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). A decrease in the impedance value from 4.3 MΩ to 13 kΩ at 1 kHz was achieved by the modified tetrodes. The cathodic charge storage capacity (CSCC) of AuNPs-PEDOT deposited tetrodes was 4.5 mC/cm2, as determined by CV measurements. The tetrodes that were electroplated with AuNPs and PEDOT exhibited an increased surface area, which reduced the tetrode impedance. In vivo recording in the ventral posterior medial (VPM) nucleus of the thalamus was performed to investigate the single-unit activity in normal rats. To evaluate the recording performance of modified tetrodes, spontaneous spike signals were recorded. The values of the L-ratio, isolation distance and signal-to-noise (SNR) confirmed that electroplating the tetrode surface with AuNPs and PEDOT improved the recording performance, and these parameters could be used to effectively quantify the spikes of each cluster.
Collapse
Affiliation(s)
- Daae Lee
- Department of Advanced Materials Engineering, Chungbuk National University, Cheongju 28644, Korea
| | - Hyeong Cheol Moon
- Department of Neurosurgery, Chungbuk National University Hospital, Cheongju 28644, Korea.,Department of Neurosurgery, Chungbuk National University, Cheongju 28644, Korea
| | - Bao-Tram Tran
- Department of Neurosurgery, Chungbuk National University, Cheongju 28644, Korea
| | - Dae-Hyuk Kwon
- Neuroscience Research Institute, Brain-Bio center, University of Suwon, Hwaseong 18323, Korea
| | - Yong Hee Kim
- Synaptic Devices Research Section, Electronics and Telecommunications Research Institute, Daejeon 34129, Korea
| | - Sang-Don Jung
- Synaptic Devices Research Section, Electronics and Telecommunications Research Institute, Daejeon 34129, Korea
| | - Jong Hoon Joo
- Department of Advanced Materials Engineering, Chungbuk National University, Cheongju 28644, Korea
| | - Young Seok Park
- Department of Neurosurgery, Chungbuk National University Hospital, Cheongju 28644, Korea.,Department of Neurosurgery, Chungbuk National University, Cheongju 28644, Korea
| |
Collapse
|
14
|
McGuire AF, Santoro F, Cui B. Interfacing Cells with Vertical Nanoscale Devices: Applications and Characterization. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2018; 11:101-126. [PMID: 29570360 PMCID: PMC6530470 DOI: 10.1146/annurev-anchem-061417-125705] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Measurements of the intracellular state of mammalian cells often require probes or molecules to breach the tightly regulated cell membrane. Mammalian cells have been shown to grow well on vertical nanoscale structures in vitro, going out of their way to reach and tightly wrap the structures. A great deal of research has taken advantage of this interaction to bring probes close to the interface or deliver molecules with increased efficiency or ease. In turn, techniques have been developed to characterize this interface. Here, we endeavor to survey this research with an emphasis on the interface as driven by cellular mechanisms.
Collapse
Affiliation(s)
- Allister F McGuire
- Department of Chemistry, Stanford University, Stanford, California 94305, USA;
| | - Francesca Santoro
- Department of Chemistry, Stanford University, Stanford, California 94305, USA;
- Center for Advanced Biomaterials for Healthcare, Istituto Italiano di Tecnologia, 80125 Naples, Italy;
| | - Bianxiao Cui
- Department of Chemistry, Stanford University, Stanford, California 94305, USA;
| |
Collapse
|
15
|
Şeker E, Shih WC, Stine KJ. Nanoporous metals by alloy corrosion: Bioanalytical and biomedical applications. MRS BULLETIN 2018; 43:49-56. [PMID: 32684663 PMCID: PMC7367097 DOI: 10.1557/mrs.2017.298] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Nanoporous metals obtained by dealloying have attracted significant attention for their unusual catalytic properties, and as model materials for fundamental studies of structure-property relationships in a variety of research areas. There has been a recent surge in the use of these metals for biomedical and bioanalytical applications, where many exciting opportunities exist. The goal of this article is to provide a review of recent progress in using nanoporous metals for biological applications, including as biosensors for detecting biomarkers of disease and multifunctional neural interfaces for monitoring and modulating the activity of neural tissue. The article emphasizes the unique properties of nanoporous gold and concludes by discussing its utility in addressing important challenges in biomedical devices.
Collapse
Affiliation(s)
- Erkin Şeker
- Department of Electrical and Computer Engineering, Multifunctional Nanoporous Metals Group, University of California, Davis, USA
| | - Wei-Chuan Shih
- Nanobiophotonics Laboratory, and Nanosystem Manufacturing Center, University of Houston, USA
| | | |
Collapse
|
16
|
Kim YH, Park J, Koo H, Kim MS, Jung SD. Fluoropolymer-Based Flexible Neural Prosthetic Electrodes for Reliable Neural Interfacing. ACS APPLIED MATERIALS & INTERFACES 2017; 9:43420-43428. [PMID: 29185336 DOI: 10.1021/acsami.7b12364] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
We covalently bound fluoropolymer (FP) films by plasma treatment followed by thermal pressing at temperatures below their melting point and fabricated an adhesion-metal-free flexible gold electrode array entirely encapsulated by the FP film, excepting the active electrode openings. The fabricated device was chemically resistant and was modified to have a lower impedance and efficient charge injection capability. The fabricated device was evaluated in vivo in rats and was confirmed to record the epidural epileptiform activity induced by chemical administration. The chemically inert nature of FPs and the gold electrode is expected to facilitate reliable neural interfacing without abiotic issues. Plasma treatment-induced covalent binding of FP films can also be utilized in a variety of applications requiring durability, such as implantable biosensors and sensor platforms operating under chemically harsh environments, including humid conditions.
Collapse
Affiliation(s)
- Yong Hee Kim
- Synaptic Devices Research Section, Electronics and Telecommunications Research Institute , 218 Gajeong-ro, Yuseng-gu, Daejeon 34129, Republic of Korea
| | - Jongkil Park
- Synaptic Devices Research Section, Electronics and Telecommunications Research Institute , 218 Gajeong-ro, Yuseng-gu, Daejeon 34129, Republic of Korea
| | - Ho Koo
- Department of Physiology, Wonkwang University School of Medicine , 895 Munwang-ro, Iksan 570-711, Jeollabuk-do, Republic of Korea
| | - Min Sun Kim
- Department of Physiology, Wonkwang University School of Medicine , 895 Munwang-ro, Iksan 570-711, Jeollabuk-do, Republic of Korea
| | - Sang-Don Jung
- Synaptic Devices Research Section, Electronics and Telecommunications Research Institute , 218 Gajeong-ro, Yuseng-gu, Daejeon 34129, Republic of Korea
| |
Collapse
|
17
|
Park J, Kim G, Jung SD. A 128-Channel FPGA-Based Real-Time Spike-Sorting Bidirectional Closed-Loop Neural Interface System. IEEE Trans Neural Syst Rehabil Eng 2017; 25:2227-2238. [DOI: 10.1109/tnsre.2017.2697415] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
18
|
Chapman CAR, Wang L, Chen H, Garrison J, Lein PJ, Seker E. Nanoporous Gold Biointerfaces: Modifying Nanostructure to Control Neural Cell Coverage and Enhance Electrophysiological Recording Performance. ADVANCED FUNCTIONAL MATERIALS 2017; 27:1604631. [PMID: 28626362 PMCID: PMC5471629 DOI: 10.1002/adfm.201604631] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Nanostructured neural interface coatings have significantly enhanced recording fidelity in both implantable and in vitro devices. As such, nano-porous gold (np-Au) has shown promise as a multifunctional neural interface coating due, in part, to its ability to promote nanostructure-mediated reduction in astrocytic surface coverage while not affecting neuronal coverage. The goal of this study is to provide insight into the mechanisms by which the np-Au nanostructure drives the differential response of neurons versus astrocytes in an in vitro model. Utilizing microfabricated libraries that display varying feature sizes of np-Au, it is demonstrated that np-Au influ-ences neural cell coverage through modulating focal adhesion formation in a feature size-dependent manner. The results here show that surfaces with small (≈30 nm) features control astrocyte spreading through inhibition of focal adhesion formation, while surfaces with large (≈170 nm and greater) features control astrocyte spreading through other mechanotransduction mechanisms. This cellular response combined with lower electrical impedance of np-Au electrodes significantly enhances the fidelity and stability of electrophysiological recordings from cortical neuronglia co-cultures relative to smooth gold electrodes. Finally, by leveraging the effect of nanostructure on neuronal versus glial cell attachment, the use of laser-based nanostructure modulation is demonstrated for selectively patterning neurons with micrometer spatial resolution.
Collapse
Affiliation(s)
| | - Ling Wang
- Department of Electrical and Computer Engineering, University of California, Davis, Davis, CA 95616, USA
| | - Hao Chen
- Department of Molecular Biosciences, University of California, Davis, Davis, CA 95616, USA
| | - Joshua Garrison
- Department of Electrical and Computer Engineering, University of California, Davis, Davis, CA 95616, USA
| | - Pamela J Lein
- Department of Molecular Biosciences, University of California, Davis, Davis, CA 95616, USA
| | - Erkin Seker
- Department of Electrical and Computer Engineering, University of California, Davis, Davis, CA 95616, USA
| |
Collapse
|
19
|
Jeong DW, Kim GH, Kim NY, Lee Z, Jung SD, Lee JO. A high-performance transparent graphene/vertically aligned carbon nanotube (VACNT) hybrid electrode for neural interfacing. RSC Adv 2017. [DOI: 10.1039/c6ra26836f] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Transparent graphene-vertically aligned carbon nanotube (VACNT) electrodes enable the dual function of optical cell monitoring and cell electrical signal measurements with exceptionally high signal amplitude.
Collapse
Affiliation(s)
- Du Won Jeong
- Advanced Materials Division
- Korea Research Institute of Chemical Technology (KRICT)
- Daejeon 34114
- Korea
| | - Gook Hwa Kim
- Synapse Device Creative Research Section
- Electronics and Telecommunications Research Institute (ETRI)
- Daejeon 34129
- Korea
| | - Na Yeon Kim
- School of Materials Science and Engineering
- Ulsan National Institute of Science and Technology (UNIST)
- Ulsan 44919
- Korea
| | - Zonghoon Lee
- School of Materials Science and Engineering
- Ulsan National Institute of Science and Technology (UNIST)
- Ulsan 44919
- Korea
| | - Sang Don Jung
- Synapse Device Creative Research Section
- Electronics and Telecommunications Research Institute (ETRI)
- Daejeon 34129
- Korea
| | - Jeong-O. Lee
- Advanced Materials Division
- Korea Research Institute of Chemical Technology (KRICT)
- Daejeon 34114
- Korea
| |
Collapse
|
20
|
Kim YH, Kim GH, Kim MS, Jung SD. Iridium Oxide-Electrodeposited Nanoporous Gold Multielectrode Array with Enhanced Stimulus Efficacy. NANO LETTERS 2016; 16:7163-7168. [PMID: 27736070 DOI: 10.1021/acs.nanolett.6b03473] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A multielectrode array (MEA) was fabricated with electrodes consisting of iridium oxide (IrOx) electrochemically deposited on nanoporous gold (NPG) to improve the moderate charge injection limit (ca. 1 mC cm-2) of NPG MEA. IrOx was electrodeposited by performing cyclic voltammetry with an IrOx deposition solution. The IrOx was electrodeposited on Au (EIROF/Au) and on NPG (EIROF/NPG) MEA, and the samples were analyzed in terms of the charge injection limit, charge storage capacity (CSC), and electrochemical impedance. The charge injection limit of the EIROF(100-cycled)/NPG MEA was estimated to be 2.3 mC cm-2 by measuring the voltage transient, and this value is sufficiently greater than the neural damage threshold (ca. 1 mC cm-2) and is also comparable to that of sputtered IrOx films. Considering the low charge injection limit (<0.1 mC cm-2) for the EIROF(100-cycled)/Au MEA, the high charge injection limit for the EIROF/NPG MEA was explained to be a result of synergetic combination of the inherently large surface area of the NPG and electrically active EIROF. The EIROF(100-cycled)/NPG exhibited an impedance of 9.7 ± 0.45 kΩ at 1 kHz and a CSC of 8 mC/cm-2, respectively, obtained via electrochemical impedance spectroscopy and integration of the cathodic current in a cyclic voltammogram. Scanning transmission electron microscopy and energy-dispersive X-ray spectroscopy are used to conduct an elemental mapping analysis of the cross-sectional structure of the EIROF/NPG and revealed that the EIROF had been uniformly deposited on the surface of the interconnected Au. The efficacy of the improvement in the charge injection limit of the EIROF/NPG MEA was evaluated with rat hippocampal slices. The EIROF/NPG electrodes exhibited a steeper increase in the negative peak amplitude of the field excitatory postsynaptic potentials (fEPSPs), even with an electrical stimulation of a lower amplitude (1-4 V), prolonged negative fEPSPs wave after peak response, and decreased serial reduction of fEPSPs compared to NPG MEA, all of which strongly indicate an improved charge injection for the EIROF/NPG MEA over NPG MEA.
Collapse
Affiliation(s)
- Yong Hee Kim
- Synaptic Devices Research Section, Electronics and Telecommunications Research Institute , 218 Gajeong-ro, Yuseong-gu, Daejeon 305-700, Republic of Korea
| | - Gook Hwa Kim
- Synaptic Devices Research Section, Electronics and Telecommunications Research Institute , 218 Gajeong-ro, Yuseong-gu, Daejeon 305-700, Republic of Korea
| | - Min Sun Kim
- Department of Physiology, Wonkwang University School of Medicine , 895 Muwang-ro, Iksan, Jeollabuk-do 570-711, Republic of Korea
| | - Sang-Don Jung
- Synaptic Devices Research Section, Electronics and Telecommunications Research Institute , 218 Gajeong-ro, Yuseong-gu, Daejeon 305-700, Republic of Korea
| |
Collapse
|
21
|
Zhao Z, Gong R, Zheng L, Wang J. In Vivo Neural Recording and Electrochemical Performance of Microelectrode Arrays Modified by Rough-Surfaced AuPt Alloy Nanoparticles with Nanoporosity. SENSORS (BASEL, SWITZERLAND) 2016; 16:E1851. [PMID: 27827893 PMCID: PMC5134510 DOI: 10.3390/s16111851] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2016] [Revised: 10/18/2016] [Accepted: 10/28/2016] [Indexed: 11/16/2022]
Abstract
In order to reduce the impedance and improve in vivo neural recording performance of our developed Michigan type silicon electrodes, rough-surfaced AuPt alloy nanoparticles with nanoporosity were deposited on gold microelectrode sites through electro-co-deposition of Au-Pt-Cu alloy nanoparticles, followed by chemical dealloying Cu. The AuPt alloy nanoparticles modified gold microelectrode sites were characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and in vivo neural recording experiment. The SEM images showed that the prepared AuPt alloy nanoparticles exhibited cauliflower-like shapes and possessed very rough surfaces with many different sizes of pores. Average impedance of rough-surfaced AuPt alloy nanoparticles modified sites was 0.23 MΩ at 1 kHz, which was only 4.7% of that of bare gold microelectrode sites (4.9 MΩ), and corresponding in vitro background noise in the range of 1 Hz to 7500 Hz decreased to 7.5 μ V rms from 34.1 μ V rms at bare gold microelectrode sites. Spontaneous spike signal recording was used to evaluate in vivo neural recording performance of modified microelectrode sites, and results showed that rough-surfaced AuPt alloy nanoparticles modified microelectrode sites exhibited higher average spike signal-to-noise ratio (SNR) of 4.8 in lateral globus pallidus (GPe) due to lower background noise compared to control microelectrodes. Electro-co-deposition of Au-Pt-Cu alloy nanoparticles combined with chemical dealloying Cu was a convenient way for increasing the effective surface area of microelectrode sites, which could reduce electrode impedance and improve the quality of in vivo spike signal recording.
Collapse
Affiliation(s)
- Zongya Zhao
- Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Institute of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.
- National Engineering Research Center of Health Care and Medical Devices, Xi'an Jiaotong University Branch, Xi'an 710049, China.
| | - Ruxue Gong
- Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Institute of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.
- National Engineering Research Center of Health Care and Medical Devices, Xi'an Jiaotong University Branch, Xi'an 710049, China.
| | - Liang Zheng
- Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Institute of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.
- National Engineering Research Center of Health Care and Medical Devices, Xi'an Jiaotong University Branch, Xi'an 710049, China.
| | - Jue Wang
- Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Institute of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.
- National Engineering Research Center of Health Care and Medical Devices, Xi'an Jiaotong University Branch, Xi'an 710049, China.
| |
Collapse
|
22
|
Hempel F, Law JKY, Nguyen TC, Munief W, Lu X, Pachauri V, Susloparova A, Vu XT, Ingebrandt S. PEDOT:PSS organic electrochemical transistor arrays for extracellular electrophysiological sensing of cardiac cells. Biosens Bioelectron 2016; 93:132-138. [PMID: 27666366 DOI: 10.1016/j.bios.2016.09.047] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2016] [Revised: 08/21/2016] [Accepted: 09/13/2016] [Indexed: 10/21/2022]
Abstract
Electrophysiological biosensors embedded in planar devices represent a state of the art approach to measure and evaluate the electrical activity of biological systems. This measurement method allows for the testing of drugs and their influences on cells or tissues, cytotoxicity, as well as the direct implementation into biological systems in vivo for signal transduction. Multi-electrode arrays (MEAs) with metal or metal-like electrodes on glass substrates are one of the most common, well-established platforms for this purpose. In recent years organic electrochemical transistors (OECTs) made of poly(2,3-dihydrothieno-1,4-dioxin)-poly(styrenesulfonate) (PEDOT:PSS) have as well shown their value in transducing and amplifying the ionic signals in biological systems. We developed OECT devices in a wafer-scale process and used them as electrophysiological biosensors measuring electrophysiological activity of the cardiac cell line HL-1. Our optimized devices show very promising properties such as good signal-to-noise ratio as well as the ability to record fast components of extracellular signals. Combined with an easy, cost effective fabrication and the transparency of the polymer, this platform offers a valuable alternative to traditional MEA systems for future cell sensing applications.
Collapse
Affiliation(s)
- Felix Hempel
- Department of Informatics and Microsystem Technology, University of Applied Sciences Kaiserslautern, Zweibrücken, Germany
| | - Jessica Ka-Yan Law
- RAM Group DE GmbH, Research and Development Center, Zweibrücken, Germany
| | - Thanh Chien Nguyen
- RAM Group DE GmbH, Research and Development Center, Zweibrücken, Germany
| | - Walid Munief
- Department of Informatics and Microsystem Technology, University of Applied Sciences Kaiserslautern, Zweibrücken, Germany
| | - Xiaoling Lu
- Department of Informatics and Microsystem Technology, University of Applied Sciences Kaiserslautern, Zweibrücken, Germany
| | - Vivek Pachauri
- Department of Informatics and Microsystem Technology, University of Applied Sciences Kaiserslautern, Zweibrücken, Germany
| | - Anna Susloparova
- Department of Informatics and Microsystem Technology, University of Applied Sciences Kaiserslautern, Zweibrücken, Germany
| | - Xuan Thang Vu
- Department of Informatics and Microsystem Technology, University of Applied Sciences Kaiserslautern, Zweibrücken, Germany; RWTH Aachen University, Lehrstuhl für Experimentalphysik I A und I. Physikalisches Institut, Aachen, Germany
| | - Sven Ingebrandt
- Department of Informatics and Microsystem Technology, University of Applied Sciences Kaiserslautern, Zweibrücken, Germany; RAM Group DE GmbH, Research and Development Center, Zweibrücken, Germany.
| |
Collapse
|
23
|
Alcaide M, Taylor A, Fjorback M, Zachar V, Pennisi CP. Boron-Doped Nanocrystalline Diamond Electrodes for Neural Interfaces: In vivo Biocompatibility Evaluation. Front Neurosci 2016; 10:87. [PMID: 27013949 PMCID: PMC4781860 DOI: 10.3389/fnins.2016.00087] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2015] [Accepted: 02/22/2016] [Indexed: 11/13/2022] Open
Abstract
Boron-doped nanocrystalline diamond (BDD) electrodes have recently attracted attention as materials for neural electrodes due to their superior physical and electrochemical properties, however their biocompatibility remains largely unexplored. In this work, we aim to investigate the in vivo biocompatibility of BDD electrodes in relation to conventional titanium nitride (TiN) electrodes using a rat subcutaneous implantation model. High quality BDD films were synthesized on electrodes intended for use as an implantable neurostimulation device. After implantation for 2 and 4 weeks, tissue sections adjacent to the electrodes were obtained for histological analysis. Both types of implants were contained in a thin fibrous encapsulation layer, the thickness of which decreased with time. Although the level of neovascularization around the implants was similar, BDD electrodes elicited significantly thinner fibrous capsules and a milder inflammatory reaction at both time points. These results suggest that BDD films may constitute an appropriate material to support stable performance of implantable neural electrodes over time.
Collapse
Affiliation(s)
- María Alcaide
- Laboratory for Stem Cell Research, Department of Health Science and Technology, Aalborg University Aalborg, Denmark
| | - Andrew Taylor
- Institute of Physics, Academy of Sciences of the Czech Republic v.v.iPrague, Czech Republic; Nano6 s.r.o.Kladno, Czech Republic
| | | | - Vladimir Zachar
- Laboratory for Stem Cell Research, Department of Health Science and Technology, Aalborg University Aalborg, Denmark
| | - Cristian P Pennisi
- Laboratory for Stem Cell Research, Department of Health Science and Technology, Aalborg University Aalborg, Denmark
| |
Collapse
|