1
|
Vilkhu RS, Vasireddy PK, Kish KE, Gogliettino AR, Lotlikar A, Hottowy P, Dabrowski W, Sher A, Litke AM, Mitra S, Chichilnisky EJ. Understanding responses to multi-electrode epiretinal stimulation using a biophysical model. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.08.20.608829. [PMID: 39229196 PMCID: PMC11370456 DOI: 10.1101/2024.08.20.608829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/05/2024]
Abstract
Objective Neural interfaces are designed to evoke specific patterns of electrical activity in populations of neurons by stimulating with many electrodes. However, currents passed simultaneously through multiple electrodes often combine nonlinearly to drive neural responses, making evoked responses difficult to predict and control. This response nonlinearity could arise from the interaction of many excitable sites in each cell, any of which can produce a spike. However, this multi-site activation hypothesis is difficult to verify experimentally. Approach We developed a biophysical model to study retinal ganglion cell (RGC) responses to multi-electrode stimulation and validated it using data collected from ex vivo preparations of the macaque retina using a microelectrode array (512 electrodes; 30µm pitch; 10µm diameter). Results First, the model was validated by reproducing essential empirical findings from single-electrode stimulation and recording, including spike waveforms over the electrode array and sigmoidal responses to injected current. Then, stimulation with two electrodes was modeled to test how the positioning of the electrodes relative to the cell affected the degree of response nonlinearity. Currents passed through pairs of electrodes positioned near the cell body or far from the axon (>40 µm) exhibited linear summation. Currents passed through pairs of electrodes close to the axon summed linearly when their locations along the axon were similar, and nonlinearly otherwise. Over a range of electrode placements, several distinct, localized spike initiation sites were observed, and the number of these sites covaried with the degree of response nonlinearity. Similar trends were observed for three-electrode stimuli. All of these trends were consistent with experimental observations. Significance These findings support the multi-site activation hypothesis for nonlinear activation of neurons, providing a biophysical interpretation of previous experimental results and potentially enabling more efficient use of multi-electrode stimuli in future neural implants.
Collapse
|
2
|
Shokri M, Gogliettino AR, Hottowy P, Sher A, Litke AM, Chichilnisky EJ, Pequito S, Muratore D. Spike sorting in the presence of stimulation artifacts: a dynamical control systems approach. J Neural Eng 2024; 21:016022. [PMID: 38271715 PMCID: PMC10853761 DOI: 10.1088/1741-2552/ad228f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 11/08/2023] [Accepted: 01/25/2024] [Indexed: 01/27/2024]
Abstract
Objective. Bi-directional electronic neural interfaces, capable of both electrical recording and stimulation, communicate with the nervous system to permit precise calibration of electrical inputs by capturing the evoked neural responses. However, one significant challenge is that stimulation artifacts often mask the actual neural signals. To address this issue, we introduce a novel approach that employs dynamical control systems to detect and decipher electrically evoked neural activity despite the presence of electrical artifacts.Approach. Our proposed method leverages the unique spatiotemporal patterns of neural activity and electrical artifacts to distinguish and identify individual neural spikes. We designed distinctive dynamical models for both the stimulation artifact and each neuron observed during spontaneous neural activity. We can estimate which neurons were active by analyzing the recorded voltage responses across multiple electrodes post-stimulation. This technique also allows us to exclude signals from electrodes heavily affected by stimulation artifacts, such as the stimulating electrode itself, yet still accurately differentiate between evoked spikes and electrical artifacts.Main results. We applied our method to high-density multi-electrode recordings from the primate retina in anex vivosetup, using a grid of 512 electrodes. Through repeated electrical stimulations at varying amplitudes, we were able to construct activation curves for each neuron. The curves obtained with our method closely resembled those derived from manual spike sorting. Additionally, the stimulation thresholds we estimated strongly agreed with those determined through manual analysis, demonstrating high reliability (R2=0.951for human 1 andR2=0.944for human 2).Significance. Our method can effectively separate evoked neural spikes from stimulation artifacts by exploiting the distinct spatiotemporal propagation patterns captured by a dense, large-scale multi-electrode array. This technique holds promise for future applications in real-time closed-loop stimulation systems and for managing multi-channel stimulation strategies.
Collapse
Affiliation(s)
- Mohammad Shokri
- Delft Center for Systems and Control, Delft University of Technology, Delft 2628 CN, The Netherlands
| | - Alex R Gogliettino
- Neurosciences PhD Program, Stanford University, Stanford, CA 94305, United States of America
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305, United States of America
| | - Paweł Hottowy
- Faculty of Physics and Applied Computer Science, AGH University of Krakow, Krakow, Poland
| | - Alexander Sher
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA, United States of America
| | - Alan M Litke
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA, United States of America
| | - E J Chichilnisky
- Departments of Neurosurgery and Ophthalmology, Stanford University, Stanford, CA 94305, United States of America
| | - Sérgio Pequito
- Division of Systems and Control, Department of Information Technology, Uppsala University, 751 05 Uppsala, Sweden
| | - Dante Muratore
- Microelectronics Department, Delft University of Technology, Delft 2628 CN, The Netherlands
| |
Collapse
|
3
|
Zaidi M, Aggarwal G, Shah NP, Karniol-Tambour O, Goetz G, Madugula SS, Gogliettino AR, Wu EG, Kling A, Brackbill N, Sher A, Litke AM, Chichilnisky EJ. Inferring light responses of primate retinal ganglion cells using intrinsic electrical signatures. J Neural Eng 2023; 20:10.1088/1741-2552/ace657. [PMID: 37433293 PMCID: PMC11067857 DOI: 10.1088/1741-2552/ace657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Accepted: 07/11/2023] [Indexed: 07/13/2023]
Abstract
Objective. Retinal implants are designed to stimulate retinal ganglion cells (RGCs) in a way that restores sight to individuals blinded by photoreceptor degeneration. Reproducing high-acuity vision with these devices will likely require inferring the natural light responses of diverse RGC types in the implanted retina, without being able to measure them directly. Here we demonstrate an inference approach that exploits intrinsic electrophysiological features of primate RGCs.Approach.First, ON-parasol and OFF-parasol RGC types were identified using their intrinsic electrical features in large-scale multi-electrode recordings from macaque retina. Then, the electrically inferred somatic location, inferred cell type, and average linear-nonlinear-Poisson model parameters of each cell type were used to infer a light response model for each cell. The accuracy of the cell type classification and of reproducing measured light responses with the model were evaluated.Main results.A cell-type classifier trained on 246 large-scale multi-electrode recordings from 148 retinas achieved 95% mean accuracy on 29 test retinas. In five retinas tested, the inferred models achieved an average correlation with measured firing rates of 0.49 for white noise visual stimuli and 0.50 for natural scenes stimuli, compared to 0.65 and 0.58 respectively for models fitted to recorded light responses (an upper bound). Linear decoding of natural images from predicted RGC activity in one retina showed a mean correlation of 0.55 between decoded and true images, compared to an upper bound of 0.81 using models fitted to light response data.Significance.These results suggest that inference of RGC light response properties from intrinsic features of their electrical activity may be a useful approach for high-fidelity sight restoration. The overall strategy of first inferring cell type from electrical features and then exploiting cell type to help infer natural cell function may also prove broadly useful to neural interfaces.
Collapse
Affiliation(s)
- Moosa Zaidi
- Stanford University School of Medicine, Stanford University, Stanford, CA, United States of America
- Neurosurgery, Stanford University, Stanford, CA, United States of America
| | - Gorish Aggarwal
- Neurosurgery, Stanford University, Stanford, CA, United States of America
- Electrical Engineering, Stanford University, Stanford, CA, United States of America
| | - Nishal P Shah
- Neurosurgery, Stanford University, Stanford, CA, United States of America
| | - Orren Karniol-Tambour
- Princeton Neuroscience Institute, Princeton University, Princeton, NJ, United States of America
| | - Georges Goetz
- Neurosurgery, Stanford University, Stanford, CA, United States of America
| | - Sasidhar S Madugula
- Stanford University School of Medicine, Stanford University, Stanford, CA, United States of America
- Neurosciences, Stanford University, Stanford, CA, United States of America
| | - Alex R Gogliettino
- Neurosciences, Stanford University, Stanford, CA, United States of America
| | - Eric G Wu
- Electrical Engineering, Stanford University, Stanford, CA, United States of America
| | - Alexandra Kling
- Neurosurgery, Stanford University, Stanford, CA, United States of America
| | - Nora Brackbill
- Physics, Stanford University, Stanford, CA, United States of America
| | - Alexander Sher
- Santa Cruz Institute for Particle Physics, University of California Santa Cruz, Santa Cruz, CA, United States of America
| | - Alan M Litke
- Santa Cruz Institute for Particle Physics, University of California Santa Cruz, Santa Cruz, CA, United States of America
| | - E J Chichilnisky
- Neurosurgery, Stanford University, Stanford, CA, United States of America
- Ophthalmology, Stanford University, Stanford, CA, United States of America
| |
Collapse
|
4
|
Panskus R, Holzapfel L, Serdijn WA, Giagka V. On the Stimulation Artifact Reduction during Electrophysiological Recording of Compound Nerve Action Potentials . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-5. [PMID: 38083005 DOI: 10.1109/embc40787.2023.10341179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Recording neuronal activity triggered by electrical impulses is a powerful tool in neuroscience research and neural engineering. It is often applied in acute electrophysiological experimental settings to record compound nerve action potentials. However, the elicited neural response is often distorted by electrical stimulus artifacts, complicating subsequent analysis. In this work, we present a model to better understand the effect of the selected amplifier configuration and the location of the ground electrode in a practical electrophysiological nerve setup. Simulation results show that the stimulus artifact can be reduced by more than an order of magnitude if the placement of the ground electrode, its impedance, and the amplifier configuration are optimized. We experimentally demonstrate the effects in three different settings, in-vivo and in-vitro.
Collapse
|
5
|
Madugula SS, Vilkhu R, Shah NP, Grosberg LE, Kling A, Gogliettino AR, Nguyen H, Hottowy P, Sher A, Litke AM, Chichilnisky EJ. Inference of Electrical Stimulation Sensitivity from Recorded Activity of Primate Retinal Ganglion Cells. J Neurosci 2023; 43:4808-4820. [PMID: 37268418 PMCID: PMC10312054 DOI: 10.1523/jneurosci.1023-22.2023] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 05/22/2023] [Accepted: 05/24/2023] [Indexed: 06/04/2023] Open
Abstract
High-fidelity electronic implants can in principle restore the function of neural circuits by precisely activating neurons via extracellular stimulation. However, direct characterization of the individual electrical sensitivity of a large population of target neurons, to precisely control their activity, can be difficult or impossible. A potential solution is to leverage biophysical principles to infer sensitivity to electrical stimulation from features of spontaneous electrical activity, which can be recorded relatively easily. Here, this approach is developed and its potential value for vision restoration is tested quantitatively using large-scale multielectrode stimulation and recording from retinal ganglion cells (RGCs) of male and female macaque monkeys ex vivo Electrodes recording larger spikes from a given cell exhibited lower stimulation thresholds across cell types, retinas, and eccentricities, with systematic and distinct trends for somas and axons. Thresholds for somatic stimulation increased with distance from the axon initial segment. The dependence of spike probability on injected current was inversely related to threshold, and was substantially steeper for axonal than somatic compartments, which could be identified by their recorded electrical signatures. Dendritic stimulation was largely ineffective for eliciting spikes. These trends were quantitatively reproduced with biophysical simulations. Results from human RGCs were broadly similar. The inference of stimulation sensitivity from recorded electrical features was tested in a data-driven simulation of visual reconstruction, revealing that the approach could significantly improve the function of future high-fidelity retinal implants.SIGNIFICANCE STATEMENT This study demonstrates that individual in situ primate retinal ganglion cells of different types respond to artificially generated, external electrical fields in a systematic manner, in accordance with theoretical predictions, that allows for prediction of electrical stimulus sensitivity from recorded spontaneous activity. It also provides evidence that such an approach could be immensely helpful in the calibration of clinical retinal implants.
Collapse
Affiliation(s)
- Sasidhar S Madugula
- Neurosciences PhD Program, Stanford University, Stanford, California 94305
- School of Medicine, Stanford University, Stanford, California 94305
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
| | - Ramandeep Vilkhu
- Department of Electrical Engineering, Stanford University, Stanford, California 94305
| | - Nishal P Shah
- Department of Neurosurgery, Stanford University, Stanford, California 94305
- Department of Electrical Engineering, Stanford University, Stanford, California 94305
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
| | - Lauren E Grosberg
- Department of Neurosurgery, Stanford University, Stanford, California 94305
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
- Facebook Reality Labs, Facebook, Mountain View, California 94040
| | - Alexandra Kling
- Department of Neurosurgery, Stanford University, Stanford, California 94305
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
| | - Alex R Gogliettino
- Neurosciences PhD Program, Stanford University, Stanford, California 94305
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
| | - Huy Nguyen
- Department of Neurosurgery, Stanford University, Stanford, California 94305
| | - Paweł Hottowy
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Krakow, Poland 30-059
| | - Alexander Sher
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, California 95064
| | - Alan M Litke
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, California 95064
| | - E J Chichilnisky
- Department of Neurosurgery, Stanford University, Stanford, California 94305
- Department of Ophthalmology, Stanford University, Stanford, California 94305
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
| |
Collapse
|
6
|
Gogliettino AR, Madugula SS, Grosberg LE, Vilkhu RS, Brown J, Nguyen H, Kling A, Hottowy P, Dąbrowski W, Sher A, Litke AM, Chichilnisky EJ. High-Fidelity Reproduction of Visual Signals by Electrical Stimulation in the Central Primate Retina. J Neurosci 2023; 43:4625-4641. [PMID: 37188516 PMCID: PMC10286946 DOI: 10.1523/jneurosci.1091-22.2023] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 05/08/2023] [Accepted: 05/10/2023] [Indexed: 05/17/2023] Open
Abstract
Electrical stimulation of retinal ganglion cells (RGCs) with electronic implants provides rudimentary artificial vision to people blinded by retinal degeneration. However, current devices stimulate indiscriminately and therefore cannot reproduce the intricate neural code of the retina. Recent work has demonstrated more precise activation of RGCs using focal electrical stimulation with multielectrode arrays in the peripheral macaque retina, but it is unclear how effective this can be in the central retina, which is required for high-resolution vision. This work probes the neural code and effectiveness of focal epiretinal stimulation in the central macaque retina, using large-scale electrical recording and stimulation ex vivo The functional organization, light response properties, and electrical properties of the major RGC types in the central retina were mostly similar to the peripheral retina, with some notable differences in density, kinetics, linearity, spiking statistics, and correlations. The major RGC types could be distinguished by their intrinsic electrical properties. Electrical stimulation targeting parasol cells revealed similar activation thresholds and reduced axon bundle activation in the central retina, but lower stimulation selectivity. Quantitative evaluation of the potential for image reconstruction from electrically evoked parasol cell signals revealed higher overall expected image quality in the central retina. An exploration of inadvertent midget cell activation suggested that it could contribute high spatial frequency noise to the visual signal carried by parasol cells. These results support the possibility of reproducing high-acuity visual signals in the central retina with an epiretinal implant.SIGNIFICANCE STATEMENT Artificial restoration of vision with retinal implants is a major treatment for blindness. However, present-day implants do not provide high-resolution visual perception, in part because they do not reproduce the natural neural code of the retina. Here, we demonstrate the level of visual signal reproduction that is possible with a future implant by examining how accurately responses to electrical stimulation of parasol retinal ganglion cells can convey visual signals. Although the precision of electrical stimulation in the central retina was diminished relative to the peripheral retina, the quality of expected visual signal reconstruction in parasol cells was greater. These findings suggest that visual signals could be restored with high fidelity in the central retina using a future retinal implant.
Collapse
Affiliation(s)
- Alex R Gogliettino
- Neurosciences PhD Program, Stanford University, Stanford, California 94305
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
| | - Sasidhar S Madugula
- Neurosciences PhD Program, Stanford University, Stanford, California 94305
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
- Stanford School of Medicine, Stanford University, Stanford, California 94305
| | - Lauren E Grosberg
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
- Department of Neurosurgery, Stanford University, Stanford, California 94305
| | - Ramandeep S Vilkhu
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
- Department of Electrical Engineering, Stanford University, Stanford, California 94305
| | - Jeff Brown
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
- Department of Neurosurgery, Stanford University, Stanford, California 94305
- Department of Electrical Engineering, Stanford University, Stanford, California 94305
| | - Huy Nguyen
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
| | - Alexandra Kling
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
- Department of Neurosurgery, Stanford University, Stanford, California 94305
| | - Paweł Hottowy
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, 30-059, Kraków, Poland
| | - Władysław Dąbrowski
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, 30-059, Kraków, Poland
| | - Alexander Sher
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, Santa Cruz, California 95064
| | - Alan M Litke
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, Santa Cruz, California 95064
| | - E J Chichilnisky
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
- Department of Neurosurgery, Stanford University, Stanford, California 94305
- Department of Electrical Engineering, Stanford University, Stanford, California 94305
- Department of Ophthalmology, Stanford University, Stanford, California 94305
| |
Collapse
|
7
|
Santiago J, Kreutzer J, Bossink E, Kallio P, le Feber J. Oxygen gradient generator to improve in vitro modeling of ischemic stroke. Front Neurosci 2023; 17:1110083. [PMID: 37056304 PMCID: PMC10086255 DOI: 10.3389/fnins.2023.1110083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Accepted: 03/08/2023] [Indexed: 03/30/2023] Open
Abstract
IntroductionIn the core of a brain infarct, perfusion is severely impeded, and neuronal death occurs within minutes. In the penumbra, an area near the core with more remaining perfusion, cells initially remain viable, but activity is significantly reduced. In principle, the penumbra can be saved if reperfusion is established on time, making it a promising target for treatment. In vitro models with cultured neurons on microelectrode arrays (MEAs) provide a useful tool to investigate how ischemic stroke affects neuronal functioning. These models tend to be uniform, focusing on the isolated penumbra, and typically lack adjacent regions such as a core and unaffected regions (normal perfusion). However, processes in these regions may affect neuronal functioning and survival in the penumbra.Materials and methodsHere, we designed, fabricated, and characterized a cytocompatible device that generates an oxygen gradient across in vitro neuronal cultures to expose cells to hypoxia of various depths from near anoxia to near normoxia. This marks a step in the path to mimic core, penumbra, and healthy tissue, and will facilitate better in vitro modeling of ischemic stroke.ResultsThe generator forms a stable and reproducible gradient within 30 min. Oxygen concentrations at the extremes are adjustable in a physiologically relevant range. Application of the generator did not negatively affect electrophysiological recordings or the viability of cultures, thus confirming the cytocompatibility of the device.DiscussionThe developed device is able to impose an oxygen gradient on neuronal cultures and may enrich in vitro stroke models.
Collapse
Affiliation(s)
- João Santiago
- Clinical Neurophysiology, University of Twente, Enschede, Netherlands
| | - Joose Kreutzer
- Micro and Nanosystems Research Group, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Elsbeth Bossink
- Biomedical and Environmental Sensor Systems, University of Twente, Enschede, Netherlands
| | - Pasi Kallio
- Micro and Nanosystems Research Group, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Joost le Feber
- Clinical Neurophysiology, University of Twente, Enschede, Netherlands
- *Correspondence: Joost le Feber,
| |
Collapse
|
8
|
Madugula SS, Gogliettino AR, Zaidi M, Aggarwal G, Kling A, Shah NP, Brown JB, Vilkhu R, Hays MR, Nguyen H, Fan V, Wu EG, Hottowy P, Sher A, Litke AM, Silva RA, Chichilnisky E. Focal electrical stimulation of human retinal ganglion cells for vision restoration. J Neural Eng 2022; 19:10.1088/1741-2552/aca5b5. [PMID: 36533865 PMCID: PMC10010036 DOI: 10.1088/1741-2552/aca5b5] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Accepted: 11/24/2022] [Indexed: 11/25/2022]
Abstract
Objective. Vision restoration with retinal implants is limited by indiscriminate simultaneous activation of many cells and cell types, which is incompatible with reproducing the neural code of the retina. Recent work has shown that primate retinal ganglion cells (RGCs), which transmit visual information to the brain, can be directly electrically activated with single-cell, single-spike, cell-type precision - however, this possibility has never been tested in the human retina. In this study we aim to characterize, for the first time, direct in situ extracellular electrical stimulation of individual human RGCs.Approach. Extracellular electrical stimulation of individual human RGCs was conducted in three human retinas ex vivo using a custom large-scale, multi-electrode array capable of simultaneous recording and stimulation. Measured activation properties were compared directly to extensive results from macaque.Main results. Precise activation was in many cases possible without activating overlying axon bundles, at low stimulation current levels similar to those used in macaque. The major RGC types could be identified and targeted based on their distinctive electrical signatures. The measured electrical activation properties of RGCs, combined with a dynamic stimulation algorithm, was sufficient to produce an evoked visual signal that was nearly optimal given the constraints of the interface.Significance. These results suggest the possibility of high-fidelity vision restoration in humans using bi-directional epiretinal implants.
Collapse
Affiliation(s)
- Sasidhar S. Madugula
- Neurosciences PhD Program, Stanford University, Stanford, CA, USA
- School of Medicine, Stanford University, Stanford, CA, USA
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
| | - Alex R. Gogliettino
- Neurosciences PhD Program, Stanford University, Stanford, CA, USA
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
| | - Moosa Zaidi
- Department of Neurosurgery, Stanford University, Stanford, CA, USA
- School of Medicine, Stanford University, Stanford, CA, USA
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
| | - Gorish Aggarwal
- Department of Neurosurgery, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
| | - Alexandra Kling
- Department of Neurosurgery, Stanford University, Stanford, CA, USA
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
| | - Nishal P. Shah
- Department of Neurosurgery, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
| | - Jeff B. Brown
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Ramandeep Vilkhu
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Madeline R. Hays
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Huy Nguyen
- Department of Neurosurgery, Stanford University, Stanford, CA, USA
| | - Victoria Fan
- Department of Neurosurgery, Stanford University, Stanford, CA, USA
| | - Eric G. Wu
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
| | - Pawel Hottowy
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Krakow, Poland
| | - Alexander Sher
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA, USA
| | - Alan M. Litke
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA, USA
| | - Ruwan A. Silva
- Department of Ophthalmology, Stanford University, Stanford, CA, USA
| | - E.J. Chichilnisky
- Department of Neurosurgery, Stanford University, Stanford, CA, USA
- Department of Ophthalmology, Stanford University, Stanford, CA, USA
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, USA
| |
Collapse
|
9
|
Weaver IA, Li A, Shields BC, Tadross MR. An Open-Source Transparent Microelectrode Array. J Neural Eng 2022; 19. [PMID: 35349992 PMCID: PMC9176384 DOI: 10.1088/1741-2552/ac620d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Accepted: 03/28/2022] [Indexed: 11/12/2022]
Abstract
Abstract
The micro-electrode array (MEA) is a cell-culture surface with integrated electrodes used for assays of electrically excitable cells and tissues. MEAs have been a workhorse in the study of neurons and myocytes, owing to the scalability and millisecond temporal resolution of the technology. However, traditional MEAs are opaque, precluding inverted microscope access to modern genetically encoded optical sensors and effectors. To address this gap, transparent MEAs have been developed. However, for many labs, transparent MEAs remain out of reach due to the cost of commercially available products, and the complexity of custom fabrication. Here, we describe an open-source transparent MEA based on the OpenEphys platform. This resource is designed to be accessible, requiring minimal microelectrode fabrication or circuit design experience. We include low-noise connectors for seamless integration with the Intan Technologies headstage, and a mechanically stable adaptor conforming to the 24-well plate footprint for compatibility with most inverted microscopes. We demonstrate the performance of this transparent MEA in a multiplexed electrical and optogenetic assay of primary rat hippocampal neurons.
Collapse
|
10
|
Wilson NR, Wang FL, Chen N, Yan SX, Daitch AL, Shi B, Sharma S, Sur M. A Platform for Spatiotemporal "Matrix" Stimulation in Brain Networks Reveals Novel Forms of Circuit Plasticity. Front Neural Circuits 2022; 15:792228. [PMID: 35069127 PMCID: PMC8766665 DOI: 10.3389/fncir.2021.792228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2021] [Accepted: 12/13/2021] [Indexed: 12/16/2022] Open
Abstract
Here we demonstrate a facile method by which to deliver complex spatiotemporal stimulation to neural networks in fast patterns, to trigger interesting forms of circuit-level plasticity in cortical areas. We present a complete platform by which patterns of electricity can be arbitrarily defined and distributed across a brain circuit, either simultaneously, asynchronously, or in complex patterns that can be easily designed and orchestrated with precise timing. Interfacing with acute slices of mouse cortex, we show that our system can be used to activate neurons at many locations and drive synaptic transmission in distributed patterns, and that this elicits new forms of plasticity that may not be observable via traditional methods, including interesting measurements of associational and sequence plasticity. Finally, we introduce an automated "network assay" for imaging activation and plasticity across a circuit. Spatiotemporal stimulation opens the door for high-throughput explorations of plasticity at the circuit level, and may provide a basis for new types of adaptive neural prosthetics.
Collapse
Affiliation(s)
- Nathan R. Wilson
- Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, United States,Nara Logics, Inc., Boston, MA, United States,*Correspondence: Nathan R. Wilson
| | - Forea L. Wang
- Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, United States
| | - Naiyan Chen
- Program in Computational and Systems Biology, Massachusetts Institute of Technology, Cambridge, MA, United States
| | - Sherry X. Yan
- Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, United States
| | - Amy L. Daitch
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, United States
| | - Bo Shi
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, United States
| | - Samvaran Sharma
- Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, United States
| | - Mriganka Sur
- Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, United States,Mriganka Sur
| |
Collapse
|
11
|
Kmon P. Highly Configurable 100 Channel Recording and Stimulating Integrated Circuit for Biomedical Experiments. SENSORS (BASEL, SWITZERLAND) 2021; 21:8482. [PMID: 34960575 PMCID: PMC8705452 DOI: 10.3390/s21248482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 12/13/2021] [Accepted: 12/16/2021] [Indexed: 11/16/2022]
Abstract
This paper presents the design results of a 100-channel integrated circuit dedicated to various biomedical experiments requiring both electrical stimulation and recording ability. The main design motivation was to develop an architecture that would comprise not only the recording and stimulation, but would also block allowing to meet different experimental requirements. Therefore, both the controllability and programmability were prime concerns, as well as the main chip parameters uniformity. The recording stage allows one to set their parameters independently from channel to channel, i.e., the frequency bandwidth can be controlled in the (0.3 Hz-1 kHz)-(20 Hz-3 kHz) (slow signal path) or (0.3 Hz-1 kHz)-4.7 kHz (fast signal path) range, while the voltage gain can be set individually either to 43.5 dB or 52 dB. Importantly, thanks to in-pixel circuitry, main system parameters may be controlled individually allowing to mitigate the circuitry components spread, i.e., lower corner frequency can be tuned in the 54 dB range with approximately 5% precision, and the upper corner frequency spread is only 4.2%, while the voltage gain spread is only 0.62%. The current stimulator may also be controlled in the broad range (69 dB) with its current setting precision being no worse than 2.6%. The recording channels' input-referred noise is equal to 8.5 µVRMS in the 10 Hz-4.7 kHz bandwidth. The single-pixel occupies 0.16 mm2 and consumes 12 µW (recording part) and 22 µW (stimulation blocks).
Collapse
Affiliation(s)
- Piotr Kmon
- Department of Measurement and Electronics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow, Poland
| |
Collapse
|
12
|
Tandon P, Bhaskhar N, Shah N, Madugula S, Grosberg L, Fan VH, Hottowy P, Sher A, Litke AM, Chichilnisky EJ, Mitra S. Automatic Identification of Axon Bundle Activation for Epiretinal Prosthesis. IEEE Trans Neural Syst Rehabil Eng 2021; 29:2496-2502. [PMID: 34784278 PMCID: PMC8860174 DOI: 10.1109/tnsre.2021.3128486] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Objective: Retinal prostheses must be able to activate cells in a selective way in order to restore high-fidelity vision. However, inadvertent activation of far-away retinal ganglion cells (RGCs) through electrical stimulation of axon bundles can produce irregular and poorly controlled percepts, limiting artificial vision. In this work, we aim to provide an algorithmic solution to the problem of detecting axon bundle activation with a bi-directional epiretinal prostheses. Methods: The algorithm utilizes electrical recordings to determine the stimulation current amplitudes above which axon bundle activation occurs. Bundle activation is defined as the axonal stimulation of RGCs with unknown soma and receptive field locations, typically beyond the electrode array. The method exploits spatiotemporal characteristics of electrically-evoked spikes to overcome the challenge of detecting small axonal spikes. Results: The algorithm was validated using large-scale, single-electrode and short pulse, ex vivo stimulation and recording experiments in macaque retina, by comparing algorithmically and manually identified bundle activation thresholds. For 88% of the electrodes analyzed, the threshold identified by the algorithm was within ±10% of the manually identified threshold, with a correlation coefficient of 0.95. Conclusion: This works presents a simple, accurate and efficient algorithm to detect axon bundle activation in epiretinal prostheses. Significance: The algorithm could be used in a closed-loop manner by a future epiretinal prosthesis to reduce poorly controlled visual percepts associated with bundle activation. Activation of distant cells via axonal stimulation will likely occur in other types of retinal implants and cortical implants, and the method may therefore be broadly applicable.
Collapse
|
13
|
Vilkhu RS, Madugula SS, Grosberg LE, Gogliettino AR, Hottowy P, Dabrowski W, Sher A, Litke AM, Mitra S, Chichilnisky EJ. Spatially patterned bi-electrode epiretinal stimulation for axon avoidance at cellular resolution. J Neural Eng 2021; 18. [PMID: 34710857 DOI: 10.1088/1741-2552/ac3450] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Accepted: 10/28/2021] [Indexed: 11/12/2022]
Abstract
Objective.Epiretinal prostheses are designed to restore vision to people blinded by photoreceptor degenerative diseases by stimulating surviving retinal ganglion cells (RGCs), which carry visual signals to the brain. However, inadvertent stimulation of RGCs at their axons can result in non-focal visual percepts, limiting the quality of artificial vision. Theoretical work has suggested that axon activation can be avoided with current stimulation designed to minimize the second spatial derivative of the induced extracellular voltage along the axon. However, this approach has not been verified experimentally at the resolution of single cells.Approach.In this work, a custom multi-electrode array (512 electrodes, 10μm diameter, 60μm pitch) was used to stimulate and record RGCs in macaque retinaex vivoat single-cell, single-spike resolution. RGC activation thresholds resulting from bi-electrode stimulation, which consisted of bipolar currents simultaneously delivered through two electrodes straddling an axon, were compared to activation thresholds from traditional single-electrode stimulation.Main results.On average, across three retinal preparations, the bi-electrode stimulation strategy reduced somatic activation thresholds (∼21%) while increasing axonal activation thresholds (∼14%), thus favoring selective somatic activation. Furthermore, individual examples revealed rescued selective activation of somas that was not possible with any individual electrode.Significance.This work suggests that a bi-electrode epiretinal stimulation strategy can reduce inadvertent axonal activation at cellular resolution, for high-fidelity artificial vision.
Collapse
Affiliation(s)
- Ramandeep S Vilkhu
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States of America
| | - Sasidhar S Madugula
- Departments of Neurosurgery, Ophthalmology, and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| | - Lauren E Grosberg
- Departments of Neurosurgery, Ophthalmology, and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| | - Alex R Gogliettino
- Departments of Neurosurgery, Ophthalmology, and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| | - Pawel Hottowy
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Krakow 30-059, Poland
| | - Wladyslaw Dabrowski
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Krakow 30-059, Poland
| | - Alexander Sher
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA, United States of America
| | - Alan M Litke
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA, United States of America
| | - Subhasish Mitra
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States of America
| | - E J Chichilnisky
- Departments of Neurosurgery, Ophthalmology, and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| |
Collapse
|
14
|
Culaclii S, Wang PM, Taccola G, Yang W, Bailey B, Chen YP, Lo YK, Liu W. A Biomimetic, SoC-Based Neural Stimulator for Novel Arbitrary-Waveform Stimulation Protocols. Front Neurosci 2021; 15:697731. [PMID: 34393710 PMCID: PMC8358079 DOI: 10.3389/fnins.2021.697731] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 07/07/2021] [Indexed: 11/15/2022] Open
Abstract
Novel neural stimulation protocols mimicking biological signals and patterns have demonstrated significant advantages as compared to traditional protocols based on uniform periodic square pulses. At the same time, the treatments for neural disorders which employ such protocols require the stimulator to be integrated into miniaturized wearable devices or implantable neural prostheses. Unfortunately, most miniaturized stimulator designs show none or very limited ability to deliver biomimetic protocols due to the architecture of their control logic, which generates the waveform. Most such designs are integrated into a single System-on-Chip (SoC) for the size reduction and the option to implement them as neural implants. But their on-chip stimulation controllers are fixed and limited in memory and computing power, preventing them from accommodating the amplitude and timing variances, and the waveform data parameters necessary to output biomimetic stimulation. To that end, a new stimulator architecture is proposed, which distributes the control logic over three component tiers - software, microcontroller firmware and digital circuits of the SoC, which is compatible with existing and future biomimetic protocols and with integration into implantable neural prosthetics. A portable prototype with the proposed architecture is designed and demonstrated in a bench-top test with various known biomimetic output waveforms. The prototype is also tested in vivo to deliver a complex, continuous biomimetic stimulation to a rat model of a spinal-cord injury. By delivering this unique biomimetic stimulation, the device is shown to successfully reestablish the connectivity of the spinal cord post-injury and thus restore motor outputs in the rat model.
Collapse
Affiliation(s)
- Stanislav Culaclii
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, United States
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, United States
| | - Po-Min Wang
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, United States
| | - Giuliano Taccola
- Neuroscience Department, International School for Advanced Studies, Trieste, Italy
- Department of Integrative Biology and Physiology, University of California, Los Angeles, Los Angeles, CA, United States
| | - William Yang
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, United States
| | - Brett Bailey
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, United States
| | - Yan-Peng Chen
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, United States
- Department of Electrical Engineering, University of California, Los Angeles, Los Angeles, CA, United States
| | - Yi-Kai Lo
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, United States
- Niche Biomedical Inc., Los Angeles, CA, United States
| | - Wentai Liu
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, United States
- Department of Electrical Engineering, University of California, Los Angeles, Los Angeles, CA, United States
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA, United States
- Brain Research Institute, University of California, Los Angeles, Los Angeles, CA, United States
| |
Collapse
|
15
|
Modular Data Acquisition System for Recording Activity and Electrical Stimulation of Brain Tissue Using Dedicated Electronics. SENSORS 2021; 21:s21134423. [PMID: 34203305 PMCID: PMC8271791 DOI: 10.3390/s21134423] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 06/14/2021] [Accepted: 06/23/2021] [Indexed: 11/25/2022]
Abstract
In this paper, we present a modular Data Acquisition (DAQ) system for simultaneous electrical stimulation and recording of brain activity. The DAQ system is designed to work with custom-designed Application Specific Integrated Circuit (ASIC) called Neurostim-3 and a variety of commercially available Multi-Electrode Arrays (MEAs). The system can control simultaneously up to 512 independent bidirectional i.e., input-output channels. We present in-depth insight into both hardware and software architectures and discuss relationships between cooperating parts of that system. The particular focus of this study was the exploration of efficient software design so that it could perform all its tasks in real-time using a standard Personal Computer (PC) without the need for data precomputation even for the most demanding experiment scenarios. Not only do we show bare performance metrics, but we also used this software to characterise signal processing capabilities of Neurostim-3 (e.g., gain linearity, transmission band) so that to obtain information on how well it can handle neural signals in real-world applications. The results indicate that each Neurostim-3 channel exhibits signal gain linearity in a wide range of input signal amplitudes. Moreover, their high-pass cut-off frequency gets close to 0.6Hz making it suitable for recording both Local Field Potential (LFP) and spiking brain activity signals. Additionally, the current stimulation circuitry was checked in terms of the ability to reproduce complex patterns. Finally, we present data acquired using our system from the experiments on a living rat’s brain, which proved we obtained physiological data from non-stimulated and stimulated tissue. The presented results lead us to conclude that our hardware and software can work efficiently and effectively in tandem giving valuable insights into how information is being processed by the brain.
Collapse
|
16
|
Shah NP, Chichilnisky EJ. Computational challenges and opportunities for a bi-directional artificial retina. J Neural Eng 2020; 17:055002. [PMID: 33089827 DOI: 10.1088/1741-2552/aba8b1] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
A future artificial retina that can restore high acuity vision in blind people will rely on the capability to both read (observe) and write (control) the spiking activity of neurons using an adaptive, bi-directional and high-resolution device. Although current research is focused on overcoming the technical challenges of building and implanting such a device, exploiting its capabilities to achieve more acute visual perception will also require substantial computational advances. Using high-density large-scale recording and stimulation in the primate retina with an ex vivo multi-electrode array lab prototype, we frame several of the major computational problems, and describe current progress and future opportunities in solving them. First, we identify cell types and locations from spontaneous activity in the blind retina, and then efficiently estimate their visual response properties by using a low-dimensional manifold of inter-retina variability learned from a large experimental dataset. Second, we estimate retinal responses to a large collection of relevant electrical stimuli by passing current patterns through an electrode array, spike sorting the resulting recordings and using the results to develop a model of evoked responses. Third, we reproduce the desired responses for a given visual target by temporally dithering a diverse collection of electrical stimuli within the integration time of the visual system. Together, these novel approaches may substantially enhance artificial vision in a next-generation device.
Collapse
Affiliation(s)
- Nishal P Shah
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States of America. Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America. Department of Neurosurgery, Stanford University, Stanford, CA, United States of America. Author to whom any correspondence should be addressed
| | | |
Collapse
|
17
|
Muralidharan M, Guo T, Shivdasani MN, Tsai D, Fried S, Li L, Dokos S, Morley JW, Lovell NH. Neural activity of functionally different retinal ganglion cells can be robustly modulated by high-rate electrical pulse trains. J Neural Eng 2020; 17:045013. [DOI: 10.1088/1741-2552/ab9a97] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
18
|
Elyahoodayan S, Jiang W, Xu H, Song D. A Multi-Channel Asynchronous Neurostimulator With Artifact Suppression for Neural Code-Based Stimulations. Front Neurosci 2019; 13:1011. [PMID: 31611764 PMCID: PMC6776638 DOI: 10.3389/fnins.2019.01011] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 09/05/2019] [Indexed: 11/18/2022] Open
Abstract
A novel neurostimulator for generating neural code-based, precise, asynchronous electrical stimulation pulses is designed, fabricated, and characterized. Through multiplexing, this system can deliver constant current biphasic pulses, with arbitrary temporal patterns, and pulse parameters to 32 electrodes using one pulse generator. The design also features a stimulus artifact suppression (SAS) technique that can be integrated with commercial amplifiers. Using an array of CMOS switches, electrodes are disconnected from recording amplifiers during stimulation, while the input of the recording system is shorted to ground through another CMOS switch to suppress ringing in the recording system. The timing of the switches used to block and suppress the stimulus artifact are crucial and are determined by the electrochemical properties of the electrode. This system allows stimulation and recording from the same electrodes to monitor local field potentials with short latencies from the region of stimulation for achieving feedback control of neural stimulation. In this way, timing between each pulse is controlled by inputs from an external source and stimulus magnitude is controlled by feed-back from neural response from the stimulated tissue. The system was implemented with low-power and compact packaged microchips to constitute an effective, cost-efficient, and miniaturized neurostimulator. The device has been first evaluated in phantom preparations and then tested in hippocampi of behaving rats. Benchtop results demonstrate the capability of the stimulator to generate arbitrary spatio-temporal pattern of stimulation pulses dictated by random number generators (RNGs) to control magnitude and timing between each individual biphasic pulse. In vivo results show that evoked potentials elicited by the neurostimulator can be recorded ∼2 ms after the termination of stimulus pulses from the same electrodes where stimulation pulses are delivered, whereas commercial amplifiers without such an artifact suppression typically result in tens to hundreds of milliseconds recovery period. This neurostimulator design is desirable in a variety of neural interface applications, particularly hippocampal memory prosthesis aiming to restore cognitive functions by reinstating neural code transmissions in the brain.
Collapse
Affiliation(s)
- Sahar Elyahoodayan
- Department of Biomedical Engineering, Center for Neural Engineering, University of Southern California, Los Angeles, CA, United States
| | - Wenxuan Jiang
- Department of Biomedical Engineering, Center for Neural Engineering, University of Southern California, Los Angeles, CA, United States
| | - Huijing Xu
- Department of Biomedical Engineering, Center for Neural Engineering, University of Southern California, Los Angeles, CA, United States
| | - Dong Song
- Department of Biomedical Engineering, Center for Neural Engineering, University of Southern California, Los Angeles, CA, United States.,Neuroscience Graduate Program, University of Southern California, Los Angeles, CA, United States
| |
Collapse
|
19
|
Shadmani A, Viswam V, Chen Y, Bounik R, Dragas J, Radivojevic M, Geissler S, Sitnikov S, Muller J, Hierlemann A. Stimulation and Artifact-Suppression Techniques for In Vitro High-Density Microelectrode Array Systems. IEEE Trans Biomed Eng 2019; 66:2481-2490. [PMID: 30605090 PMCID: PMC6711758 DOI: 10.1109/tbme.2018.2890530] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
We present novel voltage stimulation buffers with controlled output current, along with recording circuits featuring adjustable high-pass cut-off filtering to perform efficient stimulation while actively suppressing stimulation artifacts in high-density microelectrode arrays. Owing to the dense packing and close proximity of the electrodes in such systems, a stimulation through one electrode can cause large electrical artifacts on neighboring electrodes that easily saturate the corresponding recording amplifiers. To suppress such artifacts, the high-pass corner frequencies of all available 2048 recording channels can be raised from several Hz to several kHz by applying a "soft-reset" or pole-shifting technique. With the implemented artifact suppression technique, the saturation time of the recording circuits, connected to electrodes in immediate vicinity to the stimulation site, could be reduced to less than 150 μs. For the stimulation buffer, we developed a circuit, which can operate in two modes: either control of only the stimulation voltage or control of current and voltage during stimulation. The voltage-only controlled mode employs a local common-mode feedback operational transconductance amplifier with a near rail-to-rail input/output range, suitable for driving high-capacitive loads. The current/voltage controlled mode is based on a positive current conveyor generating adjustable output currents, whereas its upper and lower output voltages are limited by two feedback loops. The current/voltage controlled circuit can generate stimulation pulses up to 30 μA with less than ±0.1% linearity error in the low-current mode and up to 300 μA with less than ±0.2% linearity error in the high-current mode.
Collapse
|
20
|
Fan VH, Grosberg LE, Madugula SS, Hottowy P, Dabrowski W, Sher A, Litke AM, Chichilnisky EJ. Epiretinal stimulation with local returns enhances selectivity at cellular resolution. J Neural Eng 2019; 16:025001. [PMID: 30523958 PMCID: PMC6416068 DOI: 10.1088/1741-2552/aaeef1] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
OBJECTIVE Epiretinal prostheses are designed to restore vision in people blinded by photoreceptor degenerative diseases, by directly activating retinal ganglion cells (RGCs) using an electrode array implanted on the retina. In present-day clinical devices, current spread from the stimulating electrode to a distant return electrode often results in the activation of many cells, potentially limiting the quality of artificial vision. In the laboratory, epiretinal activation of RGCs with cellular resolution has been demonstrated with small electrodes, but distant returns may still cause undesirable current spread. Here, the ability of local return stimulation to improve the selective activation of RGCs at cellular resolution was evaluated. APPROACH A custom multi-electrode array (512 electrodes, 10 μm diameter, 60 μm pitch) was used to simultaneously stimulate and record from RGCs in isolated primate retina. Stimulation near the RGC soma with a single electrode and a distant return was compared to stimulation in which the return was provided by six neighboring electrodes. MAIN RESULTS Local return stimulation enhanced the capability to activate cells near the central electrode (<30 μm) while avoiding cells farther away (>30 μm). This resulted in an improved ability to selectively activate ON and OFF cells, including cells encoding immediately adjacent regions in the visual field. SIGNIFICANCE These results suggest that a device that restricts the electric field through local returns could optimize activation of neurons at cellular resolution, improving the quality of artificial vision.
Collapse
Affiliation(s)
- Victoria H Fan
- Departments of Neurosurgery, Ophthalmology, and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| | | | | | | | | | | | | | | |
Collapse
|
21
|
Ronchi S, Fiscella M, Marchetti C, Viswam V, Müller J, Frey U, Hierlemann A. Single-Cell Electrical Stimulation Using CMOS-Based High-Density Microelectrode Arrays. Front Neurosci 2019; 13:208. [PMID: 30918481 PMCID: PMC6424875 DOI: 10.3389/fnins.2019.00208] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 02/22/2019] [Indexed: 01/24/2023] Open
Abstract
Non-invasive electrical stimulation can be used to study and control neural activity in the brain or to alleviate somatosensory dysfunctions. One intriguing prospect is to precisely stimulate individual targeted neurons. Here, we investigated single-neuron current and voltage stimulation in vitro using high-density microelectrode arrays featuring 26,400 bidirectional electrodes at a pitch of 17.5 μm and an electrode area of 5 × 9 μm2. We determined optimal waveforms, amplitudes and durations for both stimulation modes. Owing to the high spatial resolution of our arrays and the close proximity of the electrodes to the respective neurons, we were able to stimulate the axon initial segments (AIS) with charges of less than 2 pC. This resulted in minimal artifact production and reliable readout of stimulation efficiency directly at the soma of the stimulated cell. Stimulation signals as low as 70 mV or 100 nA, with pulse durations as short as 18 μs, yielded measurable action potential initiation and propagation. We found that the required stimulation signal amplitudes decreased with cell growth and development and that stimulation efficiency did not improve at higher electric fields generated by simultaneous multi-electrode stimulation.
Collapse
Affiliation(s)
- Silvia Ronchi
- Department of Biosystems Science and Engineering, ETH Zürich, Basel, Switzerland
| | - Michele Fiscella
- Department of Biosystems Science and Engineering, ETH Zürich, Basel, Switzerland
- MaxWell Biosystems AG, Basel, Switzerland
| | - Camilla Marchetti
- Department of Biosystems Science and Engineering, ETH Zürich, Basel, Switzerland
| | - Vijay Viswam
- Department of Biosystems Science and Engineering, ETH Zürich, Basel, Switzerland
- MaxWell Biosystems AG, Basel, Switzerland
| | - Jan Müller
- Department of Biosystems Science and Engineering, ETH Zürich, Basel, Switzerland
- MaxWell Biosystems AG, Basel, Switzerland
| | - Urs Frey
- Department of Biosystems Science and Engineering, ETH Zürich, Basel, Switzerland
- MaxWell Biosystems AG, Basel, Switzerland
| | - Andreas Hierlemann
- Department of Biosystems Science and Engineering, ETH Zürich, Basel, Switzerland
| |
Collapse
|
22
|
Jung H, Kim J, Nam Y. Recovery of early neural spikes from stimulation electrodes using a DC-coupled low gain high resolution data acquisition system. J Neurosci Methods 2018; 304:118-125. [PMID: 29709657 DOI: 10.1016/j.jneumeth.2018.04.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2018] [Revised: 04/16/2018] [Accepted: 04/18/2018] [Indexed: 11/29/2022]
Abstract
BACKGROUND Neural responses to electrical stimulation provide valuable information to probe and study the network function. Especially, recording neural responses from the stimulated site provides improved neural interfacing method. However, it is difficult to measure short-delayed responses at the stimulated electrode due to the saturation of the amplifier after stimulation which is called "stimulus artifact". Despite the advances in handling stimulation artifacts, it is still very challenging to deal with the artifacts if one tries to stimulate and record from the same electrode. NEW METHOD In this paper, we developed a system consisting of 24 bit ADC and low gain DC-amplifier which allows us to record the entire responses including saturation-free stimulus artifact and neural responses with excellent resolution. RESULTS Our approach showed saturation-free recording after stimulation, which makes it possible to recover neural spike as early as in 2 ms at the stimulating electrode with digital elimination methods. COMPARISON WITH EXISTING METHODS With our system we could record neural signals after stimulation that was difficult with high gain and high pass filtered recording system due to amplifier saturation. CONCLUSIONS Our new system can enhance interface performance with its higher robustness and with simple system configuration.
Collapse
Affiliation(s)
- Hyunjun Jung
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Jintae Kim
- Department of Electronics Engineering, Konkuk University, Seoul, Republic of Korea
| | - Yoonkey Nam
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea.
| |
Collapse
|
23
|
Esler TB, Maturana MI, Kerr RR, Grayden DB, Burkitt AN, Meffin H. Biophysical basis of the linear electrical receptive fields of retinal ganglion cells. J Neural Eng 2018; 15:055001. [PMID: 29889051 DOI: 10.1088/1741-2552/aacbaa] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Responses of retinal ganglion cells to direct electrical stimulation have been shown experimentally to be well described by linear-nonlinear models. These models rely on the simplifying assumption that retinal ganglion cell responses to stimulation with an array of electrodes are driven by a simple linear weighted sum of stimulus current amplitudes from each electrode, known as the 'electrical receptive field'. OBJECTIVE This paper aims to demonstrate the biophysical basis of the linear-nonlinear model and the electrical receptive field to facilitate the development of improved stimulation strategies for retinal implants. APPROACH We compare the linear-nonlinear model of subretinal electrical stimulation with a multi-layered, biophysical, volume conductor model of retinal stimulation. MAIN RESULTS Our results show that the linear electrical receptive field of the linear-nonlinear model matches the transmembrane currents induced by electrodes (the activating function) at the site of the high-density sodium channel band with only minor discrepancies. The discrepancies are mostly eliminated by including axial current flow originating from adjacent cell compartments. Furthermore, for cells where a single linear electrical receptive field is insufficient, we show that cell responses are likely driven by multiple sites of action potential initiation with multiple distinct receptive fields, each of which can be accurately described by the activating function. SIGNIFICANCE This result establishes that the biophysical basis of the electrical receptive field of the linear-nonlinear model is the superposition of transmembrane currents induced by different electrodes at and near the site of action potential initiation. Together with existing experimental support for linear-nonlinear models of electrical stimulation, this provides a firm basis for using this much simplified model to generate more optimal stimulation patterns for retinal implants.
Collapse
Affiliation(s)
- Timothy B Esler
- NeuroEngineering Laboratory, Department of Biomedical Engineering, The University of Melbourne, Australia
| | | | | | | | | | | |
Collapse
|
24
|
Culaclii S, Kim B, Lo YK, Li L, Liu W. Online Artifact Cancelation in Same-Electrode Neural Stimulation and Recording Using a Combined Hardware and Software Architecture. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2018; 12:601-613. [PMID: 29877823 PMCID: PMC6299268 DOI: 10.1109/tbcas.2018.2816464] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Advancing studies of neural network dynamics and developments of closed-loop neural interfaces requires the ability to simultaneously stimulate and record the neural cells. Recording adjacent to or at the stimulation site produces artifact signals that are orders of magnitude larger than the neural responses of interest. These signals often saturate the recording amplifier causing distortion or loss of short-latency evoked responses. This paper proposes a method to cancel the artifact in simultaneous neural recording and stimulation on the same electrode. By combining a novel hardware architecture with concurrent software processing, the design achieves neural signal recovery in a wide range of conditions. The proposed system uniquely demonstrates same-electrode stimulation and recording, with neural signal recovery in presence of stimulation artifact 100 dB larger in magnitude than the underlying signals. The system is tested both in vitro and in vivo, during concurrent stimulation and recording on the same electrode. In vivo results in a rodent model are compared to recordings made by a commercial neural amplifier system connected in parallel.
Collapse
|
25
|
Zhou A, Johnson BC, Muller R. Toward true closed-loop neuromodulation: artifact-free recording during stimulation. Curr Opin Neurobiol 2018; 50:119-127. [DOI: 10.1016/j.conb.2018.01.012] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Revised: 01/12/2018] [Accepted: 01/17/2018] [Indexed: 11/29/2022]
|
26
|
Ling T, Boyle KC, Goetz G, Zhou P, Quan Y, Alfonso FS, Huang TW, Palanker D. Full-field interferometric imaging of propagating action potentials. LIGHT, SCIENCE & APPLICATIONS 2018; 7:107. [PMID: 30564313 PMCID: PMC6290013 DOI: 10.1038/s41377-018-0107-9] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Revised: 11/24/2018] [Accepted: 11/24/2018] [Indexed: 05/15/2023]
Abstract
Currently, cellular action potentials are detected using either electrical recordings or exogenous fluorescent probes that sense the calcium concentration or transmembrane voltage. Ca imaging has a low temporal resolution, while voltage indicators are vulnerable to phototoxicity, photobleaching, and heating. Here, we report full-field interferometric imaging of individual action potentials by detecting movement across the entire cell membrane. Using spike-triggered averaging of movies synchronized with electrical recordings, we demonstrate deformations up to 3 nm (0.9 mrad) during the action potential in spiking HEK-293 cells, with a rise time of 4 ms. The time course of the optically recorded spikes matches the electrical waveforms. Since the shot noise limit of the camera (~2 mrad/pix) precludes detection of the action potential in a single frame, for all-optical spike detection, images are acquired at 50 kHz, and 50 frames are binned into 1 ms steps to achieve a sensitivity of 0.3 mrad in a single pixel. Using a self-reinforcing sensitivity enhancement algorithm based on iteratively expanding the region of interest for spatial averaging, individual spikes can be detected by matching the previously extracted template of the action potential with the optical recording. This allows all-optical full-field imaging of the propagating action potentials without exogeneous labels or electrodes.
Collapse
Affiliation(s)
- Tong Ling
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305 USA
- Department of Ophthalmology, Stanford University, Stanford, CA 94305 USA
| | - Kevin C. Boyle
- Department of Electrical Engineering, Stanford University, Stanford, CA 94305 USA
| | - Georges Goetz
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305 USA
| | - Peng Zhou
- Department of Molecular and Cellular Physiology, Howard Hughes Medical Institute, Stanford University, Stanford, CA 94305 USA
| | - Yi Quan
- Department of Ophthalmology, Stanford University, Stanford, CA 94305 USA
| | - Felix S. Alfonso
- Department of Chemistry, Stanford University, Stanford, CA 94305 USA
| | - Tiffany W. Huang
- Department of Electrical Engineering, Stanford University, Stanford, CA 94305 USA
| | - Daniel Palanker
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305 USA
- Department of Ophthalmology, Stanford University, Stanford, CA 94305 USA
| |
Collapse
|
27
|
Cserpán D, Meszéna D, Wittner L, Tóth K, Ulbert I, Somogyvári Z, Wójcik DK. Revealing the distribution of transmembrane currents along the dendritic tree of a neuron from extracellular recordings. eLife 2017; 6:29384. [PMID: 29148974 PMCID: PMC5716668 DOI: 10.7554/elife.29384] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2017] [Accepted: 11/16/2017] [Indexed: 12/29/2022] Open
Abstract
Revealing the current source distribution along the neuronal membrane is a key step on the way to understanding neural computations; however, the experimental and theoretical tools to achieve sufficient spatiotemporal resolution for the estimation remain to be established. Here, we address this problem using extracellularly recorded potentials with arbitrarily distributed electrodes for a neuron of known morphology. We use simulations of models with varying complexity to validate the proposed method and to give recommendations for experimental applications. The method is applied to in vitro data from rat hippocampus.
Collapse
Affiliation(s)
- Dorottya Cserpán
- Wigner Research Centre for Physics, Hungarian Academy of Sciences, Budapest, Hungary
| | - Domokos Meszéna
- Institute of Cognitive Neuroscience and Psychology, Research Centre for Natural Sciences, Hungarian Academy of Sciences, Budapest, Hungary.,Faculty of Information Technology and Bionics, Pázmány Péter Catholic University, Budapest, Hungary
| | - Lucia Wittner
- Institute of Cognitive Neuroscience and Psychology, Research Centre for Natural Sciences, Hungarian Academy of Sciences, Budapest, Hungary.,National Institute of Clinical Neurosciences, Budapest, Hungary
| | - Kinga Tóth
- Institute of Cognitive Neuroscience and Psychology, Research Centre for Natural Sciences, Hungarian Academy of Sciences, Budapest, Hungary
| | - István Ulbert
- Institute of Cognitive Neuroscience and Psychology, Research Centre for Natural Sciences, Hungarian Academy of Sciences, Budapest, Hungary.,Faculty of Information Technology and Bionics, Pázmány Péter Catholic University, Budapest, Hungary.,National Institute of Clinical Neurosciences, Budapest, Hungary
| | - Zoltán Somogyvári
- Wigner Research Centre for Physics, Hungarian Academy of Sciences, Budapest, Hungary.,National Institute of Clinical Neurosciences, Budapest, Hungary.,Neuromicrosystems Ltd., Budapest, Hungary
| | - Daniel K Wójcik
- Department of Neurophysiology, Nencki Institute of Experimental Biology of Polish Academy of Sciences, Warsaw, Poland
| |
Collapse
|
28
|
Mena GE, Grosberg LE, Madugula S, Hottowy P, Litke A, Cunningham J, Chichilnisky EJ, Paninski L. Electrical stimulus artifact cancellation and neural spike detection on large multi-electrode arrays. PLoS Comput Biol 2017; 13:e1005842. [PMID: 29131818 PMCID: PMC5703587 DOI: 10.1371/journal.pcbi.1005842] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2016] [Revised: 11/27/2017] [Accepted: 10/20/2017] [Indexed: 11/18/2022] Open
Abstract
Simultaneous electrical stimulation and recording using multi-electrode arrays can provide a valuable technique for studying circuit connectivity and engineering neural interfaces. However, interpreting these measurements is challenging because the spike sorting process (identifying and segregating action potentials arising from different neurons) is greatly complicated by electrical stimulation artifacts across the array, which can exhibit complex and nonlinear waveforms, and overlap temporarily with evoked spikes. Here we develop a scalable algorithm based on a structured Gaussian Process model to estimate the artifact and identify evoked spikes. The effectiveness of our methods is demonstrated in both real and simulated 512-electrode recordings in the peripheral primate retina with single-electrode and several types of multi-electrode stimulation. We establish small error rates in the identification of evoked spikes, with a computational complexity that is compatible with real-time data analysis. This technology may be helpful in the design of future high-resolution sensory prostheses based on tailored stimulation (e.g., retinal prostheses), and for closed-loop neural stimulation at a much larger scale than currently possible.
Collapse
Affiliation(s)
- Gonzalo E. Mena
- Statistics Department, Columbia University, New York, New York, United States of America
| | - Lauren E. Grosberg
- Department of Neurosurgery and Hansen Experimental Physics Laboratory, Stanford University, Stanford, California, United States of America
| | - Sasidhar Madugula
- Department of Neurosurgery and Hansen Experimental Physics Laboratory, Stanford University, Stanford, California, United States of America
| | - Paweł Hottowy
- Physics and Applied Computer Science, AGH University of Science and Technology, Krakow, Poland
| | - Alan Litke
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, Santa Cruz, California, United States of America
| | - John Cunningham
- Statistics Department, Columbia University, New York, New York, United States of America
- Grossman Center for the Statistics of Mind and Center for Theoretical Neuroscience, Columbia University, New York, New York, United States of America
| | - E. J. Chichilnisky
- Department of Neurosurgery and Hansen Experimental Physics Laboratory, Stanford University, Stanford, California, United States of America
| | - Liam Paninski
- Statistics Department, Columbia University, New York, New York, United States of America
- Grossman Center for the Statistics of Mind and Center for Theoretical Neuroscience, Columbia University, New York, New York, United States of America
| |
Collapse
|
29
|
Culaclii S, Kim B. A hybrid hardware and software approach for cancelling stimulus artifacts during same-electrode neural stimulation and recording. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:6190-6193. [PMID: 28269665 DOI: 10.1109/embc.2016.7592142] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Recovering neural responses from electrode recordings is fundamental for understanding the dynamics of neural networks. This effort is often obscured by stimulus artifacts in the recordings, which result from stimuli injected into the electrode-tissue interface. Stimulus artifacts, which can be orders of magnitude larger than the neural responses of interest, can mask short-latency evoked responses. Furthermore, simultaneous neural stimulation and recording on the same electrode generates artifacts with larger amplitudes compared to a separate electrode setup, which inevitably overwhelm the amplifier operation and cause unrecoverable neural signal loss. This paper proposes an end-to-end system combining hardware and software techniques for actively cancelling stimulus artifacts, avoiding amplifier saturation, and recovering neural responses during current-controlled in-vivo neural stimulation and recording. The proposed system is tested in-vitro under various stimulation settings by stimulating and recording on the same electrode with a superimposed pre-recorded neural signal. Experimental results show that neural responses can be recovered with minimal distortion even during stimulus artifacts that are several orders greater in magnitude.
Collapse
|
30
|
Grosberg LE, Ganesan K, Goetz GA, Madugula SS, Bhaskhar N, Fan V, Li P, Hottowy P, Dabrowski W, Sher A, Litke AM, Mitra S, Chichilnisky EJ. Activation of ganglion cells and axon bundles using epiretinal electrical stimulation. J Neurophysiol 2017; 118:1457-1471. [PMID: 28566464 DOI: 10.1152/jn.00750.2016] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2016] [Revised: 05/30/2017] [Accepted: 05/30/2017] [Indexed: 12/17/2022] Open
Abstract
Epiretinal prostheses for treating blindness activate axon bundles, causing large, arc-shaped visual percepts that limit the quality of artificial vision. Improving the function of epiretinal prostheses therefore requires understanding and avoiding axon bundle activation. This study introduces a method to detect axon bundle activation on the basis of its electrical signature and uses the method to test whether epiretinal stimulation can directly elicit spikes in individual retinal ganglion cells without activating nearby axon bundles. Combined electrical stimulation and recording from isolated primate retina were performed using a custom multielectrode system (512 electrodes, 10-μm diameter, 60-μm pitch). Axon bundle signals were identified by their bidirectional propagation, speed, and increasing amplitude as a function of stimulation current. The threshold for bundle activation varied across electrodes and retinas, and was in the same range as the threshold for activating retinal ganglion cells near their somas. In the peripheral retina, 45% of electrodes that activated individual ganglion cells (17% of all electrodes) did so without activating bundles. This permitted selective activation of 21% of recorded ganglion cells (7% of expected ganglion cells) over the array. In one recording in the central retina, 75% of electrodes that activated individual ganglion cells (16% of all electrodes) did so without activating bundles. The ability to selectively activate a subset of retinal ganglion cells without axon bundles suggests a possible novel architecture for future epiretinal prostheses.NEW & NOTEWORTHY Large-scale multielectrode recording and stimulation were used to test how selectively retinal ganglion cells can be electrically activated without activating axon bundles. A novel method was developed to identify axon activation on the basis of its unique electrical signature and was used to find that a subset of ganglion cells can be activated at single-cell, single-spike resolution without producing bundle activity in peripheral and central retina. These findings have implications for the development of advanced retinal prostheses.
Collapse
Affiliation(s)
- Lauren E Grosberg
- Department of Neurosurgery and Hansen Experimental Physics Laboratory, Stanford University, Stanford, California;
| | - Karthik Ganesan
- Departments of Electrical Engineering and Computer Science, Stanford University, Stanford, California
| | - Georges A Goetz
- Department of Neurosurgery and Hansen Experimental Physics Laboratory, Stanford University, Stanford, California
| | - Sasidhar S Madugula
- Department of Neurosurgery and Hansen Experimental Physics Laboratory, Stanford University, Stanford, California
| | - Nandita Bhaskhar
- Departments of Electrical Engineering and Computer Science, Stanford University, Stanford, California
| | - Victoria Fan
- Department of Neurosurgery and Hansen Experimental Physics Laboratory, Stanford University, Stanford, California
| | - Peter Li
- Systems Neurobiology Laboratories, Salk Institute for Biological Studies, La Jolla, California
| | - Pawel Hottowy
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Krakow, Poland; and
| | - Wladyslaw Dabrowski
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Krakow, Poland; and
| | - Alexander Sher
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, Santa Cruz, California
| | - Alan M Litke
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, Santa Cruz, California
| | - Subhasish Mitra
- Departments of Electrical Engineering and Computer Science, Stanford University, Stanford, California
| | - E J Chichilnisky
- Department of Neurosurgery and Hansen Experimental Physics Laboratory, Stanford University, Stanford, California
| |
Collapse
|
31
|
Yang Z, Xu J, Nguyen AT, Wu T, Zhao W, Tam WK. Neuronix enables continuous, simultaneous neural recording and electrical microstimulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2016:4451-4454. [PMID: 28269266 DOI: 10.1109/embc.2016.7591715] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This paper reports a novel neurotechnology (Neuronix) and its validation through experiments. It is a miniature system-on-chip (SoC) that allows recording with simultaneous electrical microstimulation. This function has not been demonstrated before and enables precise, closed-loop neuromodulation. Neuronix represents recent advancement in brain technology and applies to both animal research and clinical applications.
Collapse
|
32
|
Obien MEJ, Deligkaris K, Bullmann T, Bakkum DJ, Frey U. Revealing neuronal function through microelectrode array recordings. Front Neurosci 2015; 8:423. [PMID: 25610364 PMCID: PMC4285113 DOI: 10.3389/fnins.2014.00423] [Citation(s) in RCA: 305] [Impact Index Per Article: 33.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2014] [Accepted: 12/03/2014] [Indexed: 12/26/2022] Open
Abstract
Microelectrode arrays and microprobes have been widely utilized to measure neuronal activity, both in vitro and in vivo. The key advantage is the capability to record and stimulate neurons at multiple sites simultaneously. However, unlike the single-cell or single-channel resolution of intracellular recording, microelectrodes detect signals from all possible sources around every sensor. Here, we review the current understanding of microelectrode signals and the techniques for analyzing them. We introduce the ongoing advancements in microelectrode technology, with focus on achieving higher resolution and quality of recordings by means of monolithic integration with on-chip circuitry. We show how recent advanced microelectrode array measurement methods facilitate the understanding of single neurons as well as network function.
Collapse
Affiliation(s)
| | - Kosmas Deligkaris
- RIKEN Quantitative Biology Center, RIKEN Kobe, Japan ; Graduate School of Frontier Biosciences, Osaka University Osaka, Japan
| | | | - Douglas J Bakkum
- Department of Biosystems Science and Engineering, ETH Zurich Basel, Switzerland
| | - Urs Frey
- RIKEN Quantitative Biology Center, RIKEN Kobe, Japan ; Graduate School of Frontier Biosciences, Osaka University Osaka, Japan ; Department of Biosystems Science and Engineering, ETH Zurich Basel, Switzerland
| |
Collapse
|
33
|
Tateno T, Nishikawa J. A CMOS IC-based multisite measuring system for stimulation and recording in neural preparations in vitro. FRONTIERS IN NEUROENGINEERING 2014; 7:39. [PMID: 25346683 PMCID: PMC4193337 DOI: 10.3389/fneng.2014.00039] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2014] [Accepted: 09/15/2014] [Indexed: 11/13/2022]
Abstract
In this report, we describe the system integration of a complementary metal oxide semiconductor (CMOS) integrated circuit (IC) chip, capable of both stimulation and recording of neurons or neural tissues, to investigate electrical signal propagation within cellular networks in vitro. The overall system consisted of three major subunits: a 5.0 × 5.0 mm CMOS IC chip, a reconfigurable logic device (field-programmable gate array, FPGA), and a PC. To test the system, microelectrode arrays (MEAs) were used to extracellularly measure the activity of cultured rat cortical neurons and mouse cortical slices. The MEA had 64 bidirectional (stimulation and recording) electrodes. In addition, the CMOS IC chip was equipped with dedicated analog filters, amplification stages, and a stimulation buffer. Signals from the electrodes were sampled at 15.6 kHz with 16-bit resolution. The measured input-referred circuitry noise was 10.1 μ V root mean square (10 Hz to 100 kHz), which allowed reliable detection of neural signals ranging from several millivolts down to approximately 33 μ Vpp. Experiments were performed involving the stimulation of neurons with several spatiotemporal patterns and the recording of the triggered activity. An advantage over current MEAs, as demonstrated by our experiments, includes the ability to stimulate (voltage stimulation, 5-bit resolution) spatiotemporal patterns in arbitrary subsets of electrodes. Furthermore, the fast stimulation reset mechanism allowed us to record neuronal signals from a stimulating electrode around 3 ms after stimulation. We demonstrate that the system can be directly applied to, for example, auditory neural prostheses in conjunction with an acoustic sensor and a sound processing system.
Collapse
Affiliation(s)
- Takashi Tateno
- Special Research Promotion Group, Graduate School of Frontier Biosciences, Osaka University Osaka, Japan ; Bioengineering and Bioinformatics, Graduate School of Information Science and Technology, Hokkaido University Sapporo, Japan
| | - Jun Nishikawa
- Bioengineering and Bioinformatics, Graduate School of Information Science and Technology, Hokkaido University Sapporo, Japan
| |
Collapse
|
34
|
Jepson LH, Hottowy P, Weiner GA, Dabrowski W, Litke AM, Chichilnisky EJ. High-fidelity reproduction of spatiotemporal visual signals for retinal prosthesis. Neuron 2014; 83:87-92. [PMID: 24910077 PMCID: PMC4465222 DOI: 10.1016/j.neuron.2014.04.044] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/23/2014] [Indexed: 11/15/2022]
Abstract
Natural vision relies on spatiotemporal patterns of electrical activity in the retina. We investigated the feasibility of veridically reproducing such patterns with epiretinal prostheses. Multielectrode recordings and visual and electrical stimulation were performed on populations of identified ganglion cells in isolated peripheral primate retina. Electrical stimulation patterns were designed to reproduce recorded waves of activity elicited by a moving visual stimulus. Electrical responses in populations of ON parasol cells exhibited high spatial and temporal precision, matching or exceeding the precision of visual responses measured in the same cells. Computational readout of electrical and visual responses produced similar estimates of stimulus speed, confirming the fidelity of electrical stimulation for biologically relevant visual signals. These results suggest the possibility of producing rich spatiotemporal patterns of retinal activity with a prosthesis and that temporal multiplexing may aid in reproducing the neural code of the retina.
Collapse
Affiliation(s)
- Lauren H Jepson
- Systems Neurobiology Laboratories, Salk Institute for Biological Studies, La Jolla, CA 92037, USA; Bioengineering Department, University of California, San Diego, La Jolla, CA 92093, USA
| | - Pawel Hottowy
- AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, 30-059 Krakow, Poland
| | - Geoffrey A Weiner
- Neuroscience Graduate Program, University of California, La Jolla, CA 92093, USA
| | - Władysław Dabrowski
- AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, 30-059 Krakow, Poland
| | - Alan M Litke
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, Santa Cruz, CA 95064, USA
| | - E J Chichilnisky
- Systems Neurobiology Laboratories, Salk Institute for Biological Studies, La Jolla, CA 92037, USA; Department of Neurosurgery and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305, USA.
| |
Collapse
|
35
|
Jepson LH, Hottowy P, Mathieson K, Gunning DE, Dąbrowski W, Litke AM, Chichilnisky EJ. Spatially patterned electrical stimulation to enhance resolution of retinal prostheses. J Neurosci 2014; 34:4871-81. [PMID: 24695706 PMCID: PMC3972715 DOI: 10.1523/jneurosci.2882-13.2014] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2013] [Revised: 01/04/2014] [Accepted: 01/30/2014] [Indexed: 11/21/2022] Open
Abstract
Retinal prostheses electrically stimulate neurons to produce artificial vision in people blinded by photoreceptor degenerative diseases. The limited spatial resolution of current devices results in indiscriminate stimulation of interleaved cells of different types, precluding veridical reproduction of natural activity patterns in the retinal output. Here we investigate the use of spatial patterns of current injection to increase the spatial resolution of stimulation, using high-density multielectrode recording and stimulation of identified ganglion cells in isolated macaque retina. As previously shown, current passed through a single electrode typically induced a single retinal ganglion cell spike with submillisecond timing precision. Current passed simultaneously through pairs of neighboring electrodes modified the probability of activation relative to injection through a single electrode. This modification could be accurately summarized by a piecewise linear model of current summation, consistent with a simple biophysical model based on multiple sites of activation. The generalizability of the piecewise linear model was tested by using the measured responses to stimulation with two electrodes to predict responses to stimulation with three electrodes. Finally, the model provided an accurate prediction of which among a set of spatial stimulation patterns maximized selective activation of a cell while minimizing activation of a neighboring cell. The results demonstrate that tailored multielectrode stimulation patterns based on a piecewise linear model may be useful in increasing the spatial resolution of retinal prostheses.
Collapse
Affiliation(s)
- Lauren H. Jepson
- Systems Neurobiology Laboratories, Salk Institute for Biological Studies, La Jolla, California 92037
- Bioengineering Department, University of California, San Diego, La Jolla, California 92093
| | - Paweł Hottowy
- AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, 30-059, Krakow, Poland
| | - Keith Mathieson
- Institute of Photonics, SUPA, University of Strathclyde, Glasgow G4 0NW, United Kingdom
| | - Deborah E. Gunning
- Institute of Photonics, SUPA, University of Strathclyde, Glasgow G4 0NW, United Kingdom
| | - Władysław Dąbrowski
- AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, 30-059, Krakow, Poland
| | - Alan M. Litke
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, Santa Cruz, California 95064, and
| | - E. J. Chichilnisky
- Systems Neurobiology Laboratories, Salk Institute for Biological Studies, La Jolla, California 92037
- Department of Neurosurgery and Hansen Experimental Physics Laboratory, Stanford University, Stanford, California 94305
| |
Collapse
|
36
|
Boinagrov D, Pangratz-Fuehrer S, Goetz G, Palanker D. Selectivity of direct and network-mediated stimulation of the retinal ganglion cells with epi-, sub- and intraretinal electrodes. J Neural Eng 2014; 11:026008. [PMID: 24608166 DOI: 10.1088/1741-2560/11/2/026008] [Citation(s) in RCA: 111] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
OBJECTIVE Intra-retinal placement of stimulating electrodes can provide close and stable proximity to target neurons. We assessed improvement in stimulation thresholds and selectivity of the direct and network-mediated retinal stimulation with intraretinal electrodes, compared to epiretinal and subretinal placements. APPROACH Stimulation thresholds of the retinal ganglion cells (RGCs) in wild-type rat retina were measured using the patch-clamp technique. Direct and network-mediated responses were discriminated using various synaptic blockers. MAIN RESULTS Three types of RGC responses were identified: short latency (SL, τ < 5 ms) originating in RGCs, medium latency (ML, 3 < τ < 70 ms) originating in the inner nuclear layer and long latency (LL, τ > 40 ms) originating in photoreceptors. Cathodic epiretinal stimulation exhibited the lowest threshold for direct RGC response and the highest direct selectivity (network/direct thresholds ratio), exceeding a factor of 3 with pulse durations below 0.5 ms. For network-mediated stimulation, the lowest threshold was obtained with anodic pulses in OPL position, and its network selectivity (direct/network thresholds ratio) increased with pulse duration, exceeding a factor of 4 at 10 ms. Latency of all three types of responses decreased with increasing strength of the stimulus. SIGNIFICANCE These results define the optimal range of pulse durations, pulse polarities and electrode placement for the retinal prostheses aiming at direct or network-mediated stimulation of RGCs.
Collapse
Affiliation(s)
- David Boinagrov
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305, USA. Department of Physics, Stanford University, Stanford, CA 94305, USA
| | | | | | | |
Collapse
|
37
|
Focal electrical stimulation of major ganglion cell types in the primate retina for the design of visual prostheses. J Neurosci 2013; 33:7194-205. [PMID: 23616529 DOI: 10.1523/jneurosci.4967-12.2013] [Citation(s) in RCA: 63] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Electrical stimulation of retinal neurons with an advanced retinal prosthesis may eventually provide high-resolution artificial vision to the blind. However, the success of future prostheses depends on the ability to activate the major parallel visual pathways of the human visual system. Electrical stimulation of the five numerically dominant retinal ganglion cell types was investigated by simultaneous stimulation and recording in isolated peripheral primate (Macaca sp.) retina using multi-electrode arrays. ON and OFF midget, ON and OFF parasol, and small bistratified ganglion cells could all be activated directly to fire a single spike with submillisecond latency using brief pulses of current within established safety limits. Thresholds for electrical stimulation were similar in all five cell types. In many cases, a single cell could be specifically activated without activating neighboring cells of the same type or other types. These findings support the feasibility of direct electrical stimulation of the major visual pathways at or near their native spatial and temporal resolution.
Collapse
|
38
|
Franke F, Jäckel D, Dragas J, Müller J, Radivojevic M, Bakkum D, Hierlemann A. High-density microelectrode array recordings and real-time spike sorting for closed-loop experiments: an emerging technology to study neural plasticity. Front Neural Circuits 2012; 6:105. [PMID: 23267316 PMCID: PMC3526803 DOI: 10.3389/fncir.2012.00105] [Citation(s) in RCA: 73] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2012] [Accepted: 12/02/2012] [Indexed: 11/30/2022] Open
Abstract
Understanding plasticity of neural networks is a key to comprehending their development and function. A powerful technique to study neural plasticity includes recording and control of pre- and post-synaptic neural activity, e.g., by using simultaneous intracellular recording and stimulation of several neurons. Intracellular recording is, however, a demanding technique and has its limitations in that only a small number of neurons can be stimulated and recorded from at the same time. Extracellular techniques offer the possibility to simultaneously record from larger numbers of neurons with relative ease, at the expenses of increased efforts to sort out single neuronal activities from the recorded mixture, which is a time consuming and error prone step, referred to as spike sorting. In this mini-review, we describe recent technological developments in two separate fields, namely CMOS-based high-density microelectrode arrays, which also allow for extracellular stimulation of neurons, and real-time spike sorting. We argue that these techniques, when combined, will provide a powerful tool to study plasticity in neural networks consisting of several thousand neurons in vitro.
Collapse
Affiliation(s)
- Felix Franke
- Department of Biosystems Science and Engineering, ETH Zürich Basle, Switzerland
| | | | | | | | | | | | | |
Collapse
|
39
|
Gunning DE, Beggs JM, Dabrowski W, Hottowy P, Kenney CJ, Sher A, Litke AM, Mathieson K. Dense arrays of micro-needles for recording and electrical stimulation of neural activity in acute brain slices. J Neural Eng 2012; 10:016007. [PMID: 23234809 DOI: 10.1088/1741-2560/10/1/016007] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE This paper describes the design, microfabrication, electrical characterization and biological evaluation of a high-density micro-needle array. The array records from and electrically stimulates individual neurons simultaneously in acute slices of brain tissue. APPROACH Acute slices, arguably the closest in-vitro model of the brain, have a damaged surface layer. Since electrophysiological recording methods rely heavily on electrode-cell proximity, this layer significantly attenuates the signal amplitude making the use of traditional planar electrodes unsuitable. To penetrate into the tissue, bypassing the tissue surface, and to record and stimulate neural activity in the healthy interior volume of the slice, an array of 61 micro-needles was fabricated. MAIN RESULTS This device is shown to record extracellular action potentials from individual neurons in acute cortical slices with a signal to noise ratio of up to ∼15:1. Electrical stimulation of individual neurons is achieved with stimulation thresholds of 1.1-2.9 µA. SIGNIFICANCE The novelty of this system is the combination of close needle spacing (60 µm), needle heights of up to 250 µm and small (5-10 µm diameter) electrodes allowing the recording of single unit activity. The array is coupled to a custom-designed readout system forming a powerful electrophysiological tool that permits two-way electrode-cell communication with populations of neurons in acute brain slices.
Collapse
Affiliation(s)
- D E Gunning
- IOP, University of Strathclyde, Glasgow G4 0NW, UK.
| | | | | | | | | | | | | | | |
Collapse
|