1
|
Yang Z, Lu J, Yan T, Ibrahim M, Wang Q, Tan L, Wang Q, Mu Y, Gao Y. Construction of a Titanium-Magnesium Composite Internal Fixation System for Repairing Bone Defects. ACS Biomater Sci Eng 2024; 10:5723-5738. [PMID: 39163588 DOI: 10.1021/acsbiomaterials.4c00949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/22/2024]
Abstract
The repair and regeneration of maxillofacial bone defects are major clinical challenges. Titanium (Ti)-magnesium (Mg) composites are a new generation of revolutionary internal fixation materials encompassing the mechanical strength and bioactive advantages of Ti and Mg alloys, respectively. This study was aimed to construct a Ti-Mg composite internal plate/screw fixation system to fix and repair bone defects. Further, the effects of different internal fixation systems on bone repair were analyzed through radiological and histological analyses. Notably, Ti6Al4V with rolled Mg foil was used as the experimental group, and a bone defect model of transverse complete amputation of the ulna in rabbits similar to the clinical condition was established. The internal fixation system with the highest osteogenic efficiency was selected based on in vivo results, and the direct and indirect bone repair abilities of the selected materials were evaluated in vitro. Notably, the thin Mg foil-Ti6Al4V internal fixation system exhibited the best fixation effect in the bone defect model and promoted the formation of new bone and early healing of bone defect areas. In vitro, the thin Mg foil-Ti6Al4V composite enhanced the activity of MC3T3-E1 cells; promoted the proliferation, adhesion, extension, and osteogenic differentiation of MC3T3-E1 cells; and regulated new bone formation. Further, it also promoted the polarization of RAW264.7 cells to M2 macrophages, induced the osteogenic immune microenvironment, and indirectly regulated the bone repair process. Therefore, a internal fixation system holds a promising potential for the internal fixation of maxillofacial bone defects. Our findings provide a theoretical and scientific basis for the design and clinical application of Ti-Mg internal fixation systems.
Collapse
Affiliation(s)
- Zhongheng Yang
- The First Affiliated Hospital of Jinzhou Medical University, Jinzhou, Liaoning 121001, China
| | - Jiarui Lu
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang 110001, China
| | - Tao Yan
- Department of Orthopedics and Sports Medicine and Joint Surgery, The People's Hospital of China Medical University, Shenyang, Liaoning 110016, China
| | - Muhammad Ibrahim
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
- School of Materials Science and Engineering, University of Science and Technology of China, Shenyang 110016, China
| | - Qingchuan Wang
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
| | - Lili Tan
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
| | - Qiang Wang
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang 110001, China
| | - Yabing Mu
- Department of Medical Bioscience, Building 6M, Umeå University, SE 90185 Umeå, Sweden
| | - Yuzhong Gao
- The First Affiliated Hospital of Jinzhou Medical University, Jinzhou, Liaoning 121001, China
| |
Collapse
|
2
|
Lewandrowski KU, Vira S, Elfar JC, Lorio MP. Advancements in Custom 3D-Printed Titanium Interbody Spinal Fusion Cages and Their Relevance in Personalized Spine Care. J Pers Med 2024; 14:809. [PMID: 39202002 PMCID: PMC11355268 DOI: 10.3390/jpm14080809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Revised: 07/17/2024] [Accepted: 07/24/2024] [Indexed: 09/03/2024] Open
Abstract
3D-printing technology has revolutionized spinal implant manufacturing, particularly in developing personalized and custom-fit titanium interbody fusion cages. These cages are pivotal in supporting inter-vertebral stability, promoting bone growth, and restoring spinal alignment. This article reviews the latest advancements in 3D-printed titanium interbody fusion cages, emphasizing their relevance in modern personalized surgical spine care protocols applied to common clinical scenarios. Furthermore, the authors review the various printing and post-printing processing technologies and discuss how engineering and design are deployed to tailor each type of implant to its patient-specific clinical application, highlighting how anatomical and biomechanical considerations impact their development and manufacturing processes to achieve optimum osteoinductive and osteoconductive properties. The article further examines the benefits of 3D printing, such as customizable geometry and porosity, that enhance osteointegration and mechanical compatibility, offering a leap forward in patient-specific solutions. The comparative analysis provided by the authors underscores the unique challenges and solutions in designing cervical, and lumbar spine implants, including load-bearing requirements and bioactivity with surrounding bony tissue to promote cell attachment. Additionally, the authors discuss the clinical outcomes associated with these implants, including the implications of improvements in surgical precision on patient outcomes. Lastly, they address strategies to overcome implementation challenges in healthcare facilities, which often resist new technology acquisitions due to perceived cost overruns and preconceived notions that hinder potential savings by providing customized surgical implants with the potential for lower complication and revision rates. This comprehensive review aims to provide insights into how modern 3D-printed titanium interbody fusion cages are made, explain quality standards, and how they may impact personalized surgical spine care.
Collapse
Affiliation(s)
- Kai-Uwe Lewandrowski
- Center for Advanced Spine Care of Southern Arizona, Division Personalized Pain Research and Education, Tucson, AZ 85712, USA
- Department of Orthopaedics, Fundación Universitaria Sanitas Bogotá, Bogotá 111321, Colombia
| | - Shaleen Vira
- Orthopedic and Sports Medicine Institute, Banner-University Tucson Campus, 755 East McDowell Road, Floor 2, Phoenix, AZ 85006, USA;
| | - John C. Elfar
- Department of Orthopaedic Surgery, University of Arizona College of Medicine, Tucson, AZ 85721, USA
| | - Morgan P. Lorio
- Advanced Orthopedics, 499 East Central Parkway, Altamonte Springs, FL 32701, USA;
- Orlando College of Osteopathic Medicine, Orlando, FL 34787, USA
| |
Collapse
|
3
|
Hu Y, Chen X, Chu Z, Tian Q, Luo L, Gan Z, Zhong J, Yuan Z, Zhu B, Dong W. Micro-Computed Tomography Analysis and Histological Observation of the Screw-Bone Interface of Novel Porous Scaffold Core Pedicle Screws and Hollow Lateral Hole Pedicle Screws: A Comparative Study in Bama Pigs. World Neurosurg 2024:S1878-8750(24)01263-4. [PMID: 39059721 DOI: 10.1016/j.wneu.2024.07.123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2024] [Accepted: 07/17/2024] [Indexed: 07/28/2024]
Abstract
OBJECTIVE Screw loosening is a common complication of pedicle screw internal fixation surgery. This study aimed to investigate whether the application of a porous scaffold structure can increase the contact area between screws and bone tissue by comparing the bone ingrowth and screw-bone interface of porous scaffold core pedicle screws (PSCPSs) and hollow lateral hole pedicle screws (HLHPSs) in the lumbar spine of Bama pigs. METHODS Sixteen pedicle screws of both types were implanted into the bilateral pedicles of the L1-4 vertebrae of 2 Bama pigs. All Bama pigs were sacrificed and the lumbar spine was freed into individual vertebrae at 16 weeks postoperatively. After the vertebrae were made into screw-centered specimens, micro-computed tomography analysis and histological observation were performed to assess the screw-bone interface and bone growth around and within the screws. RESULTS We found that the bone condition around PSCPSs and HLHPSs did not show significant differences on micro-computed tomography three-dimensional reconstruction images. CT transverse views showed different bone growth inside the 2 screws. In PSCPSs, bone tissue was seen to fill the internal pores and was evenly distributed around each strut. Inside HLHPSs, bone growth was confined to 1 side of the screw and did not fill the entire cavity. Osteometric analysis showed that bone volume fraction and trabecular number, the parameters representing bone mass, were higher in PSCPSs than in HLHPSs. These differences were not statistically significant (P > 0.05). Histological observations visualized that the osseointegration within PSCPSs was superior to that of HLHPSs, and the tight integration of bone tissue with the porous scaffold resulted in a larger screw-bone integration area in PSCPSs than in HLHPSs. CONCLUSIONS Compared with HLHPSs, PSCPSs possessing a porous scaffold core could promote bone ingrowth and osseointegration, resulting in an effective enhancement of the combined area of the screw-bone interface.
Collapse
Affiliation(s)
- Yong Hu
- Department of Spine Surgery, Ningbo No. 6 Hospital of Ningbo University, Ningbo, China.
| | - Xijiong Chen
- Health Science Center, Ningbo University, Ningbo, China
| | - Zhentao Chu
- Health Science Center, Ningbo University, Ningbo, China
| | - Quanliang Tian
- Department of Spine Surgery, Qianxinan Autonomous Prefecture Hospital of TCM, Xingyi, China
| | - Linwei Luo
- Health Science Center, Ningbo University, Ningbo, China
| | - Zhiwei Gan
- Health Science Center, Ningbo University, Ningbo, China
| | - Jianbin Zhong
- Department of Spine Surgery, Ningbo No. 6 Hospital of Ningbo University, Ningbo, China
| | - Zhenshan Yuan
- Department of Spine Surgery, Ningbo No. 6 Hospital of Ningbo University, Ningbo, China
| | - Bingke Zhu
- Department of Spine Surgery, Ningbo No. 6 Hospital of Ningbo University, Ningbo, China
| | - Weixin Dong
- Department of Spine Surgery, Ningbo No. 6 Hospital of Ningbo University, Ningbo, China
| |
Collapse
|
4
|
Emonson NS, Dharmasiri B, Gordon EB, Borkar A, Newman B, Wickramasingha YA, Coia P, Harte T, Newton J, Allardyce BJ, Stojcevski F, Kaplan DL, Henderson LC. Biomedical Applications of Electro-Initiated Polymerisation on Ti6Al4 V Titanium Alloy using Silk Fibroin Coatings for Antibiotic Delivery and Improved Cell Metabolism. Chempluschem 2024; 89:e202300555. [PMID: 38036452 DOI: 10.1002/cplu.202300555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 11/29/2023] [Accepted: 11/30/2023] [Indexed: 12/02/2023]
Abstract
Silk fibroin interactions with metallic surfaces can provide utility for medical materials and devices. Toward this goal, titanium alloy (Ti6Al4 V) was covalently grafted with polyacrylamide via electrochemically reducing 4-nitrobenzene diazonium salt in the presence of acrylamide. Analysis of the modified surfaces with FT-IR spectra, SEM and AFM were consistent with surface grafting. Functionalised titanium samples with a silk fibroin membrane, with and without impregnated therapeutics, were used to assess cytocompatibility and drug delivery. Initial cytocompatibility experiments using fibroblasts showed that the functionalised samples, both with and without silk fibroin coatings, supported significant increases between 72-136 % in cell metabolism, compared to the controls after 7 days. A 7-days release profiling showed consistent bacterial inhibition through gentamicin release with average inhibition zones of 239 mm2. Over a 5-week period, silk fibroin coated samples, both with and without growth factors, supported better human mesenchymal stem cell metabolism with increases reaching 1031 % and 388 %, respectively, compared to samples without the silk fibroin coating with.
Collapse
Affiliation(s)
- Nicholas S Emonson
- Institute for Frontier Materials, Deakin University, Waurn Ponds, VIC, 3216, Australia
| | - Bhagya Dharmasiri
- Institute for Frontier Materials, Deakin University, Waurn Ponds, VIC, 3216, Australia
| | - Edward B Gordon
- Biomedical Engineering Department, Tufts University, Medford, MA, 02155, USA
| | - Ameya Borkar
- Institute for Frontier Materials, Deakin University, Waurn Ponds, VIC, 3216, Australia
| | - Ben Newman
- Institute for Frontier Materials, Deakin University, Waurn Ponds, VIC, 3216, Australia
| | | | - Piers Coia
- Institute for Frontier Materials, Deakin University, Waurn Ponds, VIC, 3216, Australia
| | - Timothy Harte
- Institute for Frontier Materials, Deakin University, Waurn Ponds, VIC, 3216, Australia
| | - Jazmyn Newton
- Institute for Frontier Materials, Deakin University, Waurn Ponds, VIC, 3216, Australia
| | - Benjamin J Allardyce
- Institute for Frontier Materials, Deakin University, Waurn Ponds, VIC, 3216, Australia
| | - Filip Stojcevski
- Institute for Frontier Materials, Deakin University, Waurn Ponds, VIC, 3216, Australia
| | - David L Kaplan
- Biomedical Engineering Department, Tufts University, Medford, MA, 02155, USA
| | - Luke C Henderson
- Institute for Frontier Materials, Deakin University, Waurn Ponds, VIC, 3216, Australia
| |
Collapse
|
5
|
Liu W, Wang D, He G, Li T, Zhang X. A novel porous titanium with engineered surface for bone defect repair in load-bearing position. J Biomed Mater Res A 2024; 112:1083-1092. [PMID: 38411355 DOI: 10.1002/jbm.a.37689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2023] [Revised: 02/01/2024] [Accepted: 02/06/2024] [Indexed: 02/28/2024]
Abstract
Porous titanium exhibits low elastic modulus and porous structure is thought to be a promising implant in bone defect repair. However, the bioinert and low mechanical strength of porous titanium have limited its clinical application, especially in load-bearing bone defect repair. Our previous study has reported an infiltration casting and acid corrosion (IC-AC) method to fabricate a novel porous titanium (pTi) with 40% porosity and 0.4 mm pore diameter, which exerts mechanical property matching with cortical bone and interconnected channels. In this study, we introduced a nanoporous coating and incorporated an osteogenic element strontium (Sr) on the surface of porous titanium (named as Sr-micro arch oxidation [MAO]) to improve the osteogenic ability of the pTi by MAO. Better biocompatibility of Sr-MAO was verified by cell adhesion experiment and cell counting kit-8 (CCK-8) test. The in vitro osteogenic-related tests such as immunofluorescence staining, alkaline phosphatase staining and real-time polymerase chain reaction (RT-PCR) demonstrated better osteogenic ability of Sr-MAO. Femoral bone defect repair model was employed to evaluate the osseointegration of samples in vivo. Results of micro-CT scanning, sequential fluorochrome labeling and Van Gieson staining suggested that Sr-MAO showed better in vivo osteogenic ability than other groups. Taking results of both in vitro and in vivo experiment together, this study indicated the Sr-MAO porous titanium could be a promising implant load-bearing bone defect.
Collapse
Affiliation(s)
- Wei Liu
- Department of Orthopaedics, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Dong Wang
- School of Mechanical and Electrical Engineering, Henan University of Technology, Zhengzhou, China
| | - Guo He
- State Key Lab of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Tingting Li
- Department of Infection Disease, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xianlong Zhang
- Department of Orthopaedics, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
6
|
Liang H, Chen B, Duan S, Yang L, Xu R, Zhang H, Sun M, Zhou X, Liu H, Wen H, Cai Z. Treatment of complex limb fractures with 3D printing technology combined with personalized plates: a retrospective study of case series and literature review. Front Surg 2024; 11:1383401. [PMID: 38817945 PMCID: PMC11137251 DOI: 10.3389/fsurg.2024.1383401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Accepted: 05/09/2024] [Indexed: 06/01/2024] Open
Abstract
Background In recent years, 3D printing technology has made significant strides in the medical field. With the advancement of orthopedics, there is an increasing pursuit of high surgical quality and optimal functional recovery. 3D printing enables the creation of precise physical models of fractures, and customized personalized steel plates can better realign and more comprehensively and securely fix fractures. These technologies improve preoperative diagnosis, simulation, and planning for complex limb fractures, providing patients with better treatment options. Patients and methods Five typical cases were selected from a pool of numerous patients treated with 3D printing technology combined with personalized custom steel plates at our hospital. These cases were chosen to demonstrate the entire process of printing 3D models and customizing individualized steel plates, including details of the patients' surgeries and treatment procedures. Literature reviews were conducted, with a focus on highlighting the application of 3D printing technology combined with personalized custom steel plates in the treatment of complex limb fractures. Results 3D printing technology can produce accurate physical models of fractures, and personalized custom plates can achieve better fracture realignment and more comprehensive and robust fixation. These technologies provide patients with better treatment options. Conclusion The use of 3D printing models and personalized custom steel plates can improve preoperative diagnosis, simulation, and planning for complex limb fractures, realizing personalized medicine. This approach helps reduce surgical time, minimize trauma, enhance treatment outcomes, and improve patient functional recovery.
Collapse
Affiliation(s)
- Hairui Liang
- Department of Orthopedics Surgery, Central Hospital Affiliated to Shenyang Medical College, Shenyang, Liaoning, China
| | - Beibei Chen
- Department of Orthopedics Surgery, Central Hospital Affiliated to Shenyang Medical College, Shenyang, Liaoning, China
| | - Siyu Duan
- Department of Orthopedics Surgery, Central Hospital Affiliated to Shenyang Medical College, Shenyang, Liaoning, China
| | - Lei Yang
- School of Pharmacy, Inner Mongolia Medical University, Inner Mongolia Autonomous Region, Shenyang, China
| | - Rongda Xu
- Department of Orthopedics Surgery, Central Hospital Affiliated to Shenyang Medical College, Shenyang, Liaoning, China
| | - He Zhang
- Department of Orthopedics Surgery, Central Hospital Affiliated to Shenyang Medical College, Shenyang, Liaoning, China
| | - Ming Sun
- Department of Orthopedics Surgery, Central Hospital Affiliated to Shenyang Medical College, Shenyang, Liaoning, China
| | - Xueting Zhou
- Department of Orthopedics Surgery, Central Hospital Affiliated to Shenyang Medical College, Shenyang, Liaoning, China
| | - Hanfei Liu
- Department of Orthopedics Surgery, Central Hospital Affiliated to Shenyang Medical College, Shenyang, Liaoning, China
| | - Hang Wen
- Department of Orthopedics Surgery, Central Hospital Affiliated to Shenyang Medical College, Shenyang, Liaoning, China
| | - Zhencun Cai
- Department of Orthopedics Surgery, Central Hospital Affiliated to Shenyang Medical College, Shenyang, Liaoning, China
- Key Laboratory of Human Ethnic Specificity and Phenomics of Critical Illness in Liaoning Province, Shenyang Medical College, Shenyang, China
| |
Collapse
|
7
|
Akay S, Yaghmur A. Recent Advances in Antibacterial Coatings to Combat Orthopedic Implant-Associated Infections. Molecules 2024; 29:1172. [PMID: 38474684 DOI: 10.3390/molecules29051172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 03/02/2024] [Accepted: 03/03/2024] [Indexed: 03/14/2024] Open
Abstract
Implant-associated infections (IAIs) represent a major health burden due to the complex structural features of biofilms and their inherent tolerance to antimicrobial agents and the immune system. Thus, the viable options to eradicate biofilms embedded on medical implants are surgical operations and long-term and repeated antibiotic courses. Recent years have witnessed a growing interest in the development of robust and reliable strategies for prevention and treatment of IAIs. In particular, it seems promising to develop materials with anti-biofouling and antibacterial properties for combating IAIs on implants. In this contribution, we exclusively focus on recent advances in the development of modified and functionalized implant surfaces for inhibiting bacterial attachment and eventually biofilm formation on orthopedic implants. Further, we highlight recent progress in the development of antibacterial coatings (including self-assembled nanocoatings) for preventing biofilm formation on orthopedic implants. Among the recently introduced approaches for development of efficient and durable antibacterial coatings, we focus on the use of safe and biocompatible materials with excellent antibacterial activities for local delivery of combinatorial antimicrobial agents for preventing and treating IAIs and overcoming antimicrobial resistance.
Collapse
Affiliation(s)
- Seref Akay
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, 2100 Copenhagen, Denmark
| | - Anan Yaghmur
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, 2100 Copenhagen, Denmark
| |
Collapse
|
8
|
Jing Z, Yuan W, Wang J, Ni R, Qin Y, Mao Z, Wei F, Song C, Zheng Y, Cai H, Liu Z. Simvastatin/hydrogel-loaded 3D-printed titanium alloy scaffolds suppress osteosarcoma via TF/NOX2-associated ferroptosis while repairing bone defects. Bioact Mater 2024; 33:223-241. [PMID: 38045570 PMCID: PMC10689208 DOI: 10.1016/j.bioactmat.2023.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 10/18/2023] [Accepted: 11/02/2023] [Indexed: 12/05/2023] Open
Abstract
Postoperative anatomical reconstruction and prevention of local recurrence after tumor resection are two vital clinical challenges in osteosarcoma treatment. A three-dimensional (3D)-printed porous Ti6Al4V scaffold (3DTi) is an ideal material for reconstructing critical bone defects with numerous advantages over traditional implants, including a lower elasticity modulus, stronger bone-implant interlock, and larger drug-loading space. Simvastatin is a multitarget drug with anti-tumor and osteogenic potential; however, its efficiency is unsatisfactory when delivered systematically. Here, simvastatin was loaded into a 3DTi using a thermosensitive poly (lactic-co-glycolic) acid (PLGA)-polyethylene glycol (PEG)-PLGA hydrogel as a carrier to exert anti-osteosarcoma and osteogenic effects. Newly constructed simvastatin/hydrogel-loaded 3DTi (Sim-3DTi) was comprehensively appraised, and its newfound anti-osteosarcoma mechanism was explained. Specifically, in a bone defect model of rabbit condyles, Sim-3DTi exhibited enhanced osteogenesis, bone in-growth, and osseointegration compared with 3DTi alone, with greater bone morphogenetic protein 2 expression. In our nude mice model, simvastatin loading reduced tumor volume by 59%-77 % without organic damage, implying good anti-osteosarcoma activity and biosafety. Furthermore, Sim-3DTi induced ferroptosis by upregulating transferrin and nicotinamide adenine dinucleotide phosphate oxidase 2 levels in osteosarcoma both in vivo and in vitro. Sim-3DTi is a promising osteogenic bone substitute for osteosarcoma-related bone defects, with a ferroptosis-mediated anti-osteosarcoma effect.
Collapse
Affiliation(s)
- Zehao Jing
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Wanqiong Yuan
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Jiedong Wang
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Renhua Ni
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Yu Qin
- School of Materials Science and Engineering, Peking University, Beijing, 100871, People's Republic of China
| | - Zhinan Mao
- School of Materials Science and Engineering, Peking University, Beijing, 100871, People's Republic of China
| | - Feng Wei
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Chunli Song
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
| | - Yufeng Zheng
- School of Materials Science and Engineering, Peking University, Beijing, 100871, People's Republic of China
| | - Hong Cai
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
| | - Zhongjun Liu
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| |
Collapse
|
9
|
Liu G, Wei X, Zhai Y, Zhang J, Li J, Zhao Z, Guan T, Zhao D. 3D printed osteochondral scaffolds: design strategies, present applications and future perspectives. Front Bioeng Biotechnol 2024; 12:1339916. [PMID: 38425994 PMCID: PMC10902174 DOI: 10.3389/fbioe.2024.1339916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Accepted: 02/02/2024] [Indexed: 03/02/2024] Open
Abstract
Articular osteochondral (OC) defects are a global clinical problem characterized by loss of full-thickness articular cartilage with underlying calcified cartilage through to the subchondral bone. While current surgical treatments can relieve pain, none of them can completely repair all components of the OC unit and restore its original function. With the rapid development of three-dimensional (3D) printing technology, admirable progress has been made in bone and cartilage reconstruction, providing new strategies for restoring joint function. 3D printing has the advantages of fast speed, high precision, and personalized customization to meet the requirements of irregular geometry, differentiated composition, and multi-layered boundary layer structures of joint OC scaffolds. This review captures the original published researches on the application of 3D printing technology to the repair of entire OC units and provides a comprehensive summary of the recent advances in 3D printed OC scaffolds. We first introduce the gradient structure and biological properties of articular OC tissue. The considerations for the development of 3D printed OC scaffolds are emphatically summarized, including material types, fabrication techniques, structural design and seed cells. Especially from the perspective of material composition and structural design, the classification, characteristics and latest research progress of discrete gradient scaffolds (biphasic, triphasic and multiphasic scaffolds) and continuous gradient scaffolds (gradient material and/or structure, and gradient interface) are summarized. Finally, we also describe the important progress and application prospect of 3D printing technology in OC interface regeneration. 3D printing technology for OC reconstruction should simulate the gradient structure of subchondral bone and cartilage. Therefore, we must not only strengthen the basic research on OC structure, but also continue to explore the role of 3D printing technology in OC tissue engineering. This will enable better structural and functional bionics of OC scaffolds, ultimately improving the repair of OC defects.
Collapse
Affiliation(s)
- Ge Liu
- School of Mechanical Engineering, Dalian Jiaotong University, Dalian, China
- Department of Orthopedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, China
| | - Xiaowei Wei
- Department of Orthopedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, China
| | - Yun Zhai
- School of Mechanical Engineering, Dalian Jiaotong University, Dalian, China
| | - Jingrun Zhang
- Department of Orthopedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, China
| | - Junlei Li
- Department of Orthopedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, China
| | - Zhenhua Zhao
- Department of Orthopedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, China
| | - Tianmin Guan
- School of Mechanical Engineering, Dalian Jiaotong University, Dalian, China
| | - Deiwei Zhao
- Department of Orthopedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, China
| |
Collapse
|
10
|
Huang D, Ye Z, Wang J, Chen F, Liu H, Huang J. Reconstruction of recurrent shoulder dislocation with glenoid bone defect with 3D-printed titanium alloy pad: outcomes at 2-year minimum follow-up. BMC Musculoskelet Disord 2024; 25:29. [PMID: 38166887 PMCID: PMC10763388 DOI: 10.1186/s12891-023-07148-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 12/22/2023] [Indexed: 01/05/2024] Open
Abstract
BACKGROUND To evaluate the outcome of shoulder arthroscopy-assisted implantation of three-dimensional (3D)-printed titanium pads for recurrent shoulder dislocation with glenoid bone defects. METHODS From June 2019 to May 2020, the clinical efficacy of 3D printed titanium pad implantation assisted by shoulder arthroscopy, for the treatment of recurrent shoulder dislocations with shoulder glenoid defects was retrospectively analyzed. The American Shoulder and Elbow Surgeons (ASES) shoulder, Rowe, and Constant scores were recorded before surgery and at 3 months, 6 months, 1 year, and 2 years after surgery. 3D computed tomography (CT) and magnetic resonance imaging were used to evaluate the location of the glenoid pad, bone ingrowth, joint degeneration, and osteochondral damage. RESULTS The mean age of the 12 patients was 21.4 (19-24) years and the mean follow-up time was 27.6 (24-35) months. The Visual Analog Scale score significantly improved from 5.67 ± 1.98 preoperatively to 0.83 ± 0.58 postoperatively (p = 0.012). The postoperative ASES score was significantly increased to 87.91 ± 3.47 compared with preoperative ASES score (46.79 ± 6.45) (p < 0.01). Rowe and Constant scores also improved from 22.5 ± 12.34 and 56.58 ± 7.59 preoperatively to 90.83 ± 4.69 and 90.17 ± 1.89 at 2 years postoperatively, respectively. CT performed 2 years after surgery showed that the pad perfectly replenished the bone-defective part of the shoulder glenoid and restored the articular surface curvature of the shoulder glenoid in the anterior-posterior direction, and the bone around the central riser of the pad was tightly united. Magnetic resonance imaging 2 years after surgery showed that the humeral head osteochondral bone was intact, and there was no obvious osteochondral damage. CONCLUSIONS 3D printed titanium pads are a reliable, safe, and effective surgical procedure for treating recurrent shoulder dislocations with glenoid bone defects.
Collapse
Affiliation(s)
- Danlei Huang
- Department of Orthopedics, Chenggong Hospital of Xiamen University (the 73th Group Military Hospital of People's Liberation Army), 94 Wenyuan Road, Siming District, Xiamen City, Fujian Province, 361000, China
| | - Zhiyang Ye
- Department of Orthopedics, Chenggong Hospital of Xiamen University (the 73th Group Military Hospital of People's Liberation Army), 94 Wenyuan Road, Siming District, Xiamen City, Fujian Province, 361000, China
| | - Jun Wang
- Department of Orthopedics, Chenggong Hospital of Xiamen University (the 73th Group Military Hospital of People's Liberation Army), 94 Wenyuan Road, Siming District, Xiamen City, Fujian Province, 361000, China
| | - Feixiong Chen
- Department of Orthopedics, Chenggong Hospital of Xiamen University (the 73th Group Military Hospital of People's Liberation Army), 94 Wenyuan Road, Siming District, Xiamen City, Fujian Province, 361000, China
| | - Haoyuan Liu
- Department of Orthopedics, Chenggong Hospital of Xiamen University (the 73th Group Military Hospital of People's Liberation Army), 94 Wenyuan Road, Siming District, Xiamen City, Fujian Province, 361000, China
| | - Jianming Huang
- Department of Orthopedics, Chenggong Hospital of Xiamen University (the 73th Group Military Hospital of People's Liberation Army), 94 Wenyuan Road, Siming District, Xiamen City, Fujian Province, 361000, China.
| |
Collapse
|
11
|
Timofticiuc IA, Călinescu O, Iftime A, Dragosloveanu S, Caruntu A, Scheau AE, Badarau IA, Didilescu AC, Caruntu C, Scheau C. Biomaterials Adapted to Vat Photopolymerization in 3D Printing: Characteristics and Medical Applications. J Funct Biomater 2023; 15:7. [PMID: 38248674 PMCID: PMC10816811 DOI: 10.3390/jfb15010007] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 12/07/2023] [Accepted: 12/19/2023] [Indexed: 01/23/2024] Open
Abstract
Along with the rapid and extensive advancements in the 3D printing field, a diverse range of uses for 3D printing have appeared in the spectrum of medical applications. Vat photopolymerization (VPP) stands out as one of the most extensively researched methods of 3D printing, with its main advantages being a high printing speed and the ability to produce high-resolution structures. A major challenge in using VPP 3D-printed materials in medicine is the general incompatibility of standard VPP resin mixtures with the requirements of biocompatibility and biofunctionality. Instead of developing completely new materials, an alternate approach to solving this problem involves adapting existing biomaterials. These materials are incompatible with VPP 3D printing in their pure form but can be adapted to the VPP chemistry and general process through the use of innovative mixtures and the addition of specific pre- and post-printing steps. This review's primary objective is to highlight biofunctional and biocompatible materials that have been adapted to VPP. We present and compare the suitability of these adapted materials to different medical applications and propose other biomaterials that could be further adapted to the VPP 3D printing process in order to fulfill patient-specific medical requirements.
Collapse
Affiliation(s)
- Iosif-Aliodor Timofticiuc
- Department of Physiology, The “Carol Davila” University of Medicine and Pharmacy, 8 Eroii Sanitari Boulevard, 050474 Bucharest, Romania
| | - Octavian Călinescu
- Department of Biophysics, The “Carol Davila” University of Medicine and Pharmacy, 8 Eroii Sanitari Boulevard, 050474 Bucharest, Romania
| | - Adrian Iftime
- Department of Biophysics, The “Carol Davila” University of Medicine and Pharmacy, 8 Eroii Sanitari Boulevard, 050474 Bucharest, Romania
| | - Serban Dragosloveanu
- Department of Orthopaedics and Traumatology, The “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania
- Department of Orthopaedics, “Foisor” Clinical Hospital of Orthopaedics, Traumatology and Osteoarticular TB, 021382 Bucharest, Romania
| | - Ana Caruntu
- Department of Oral and Maxillofacial Surgery, “Carol Davila” Central Military Emergency Hospital, 010825 Bucharest, Romania
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Titu Maiorescu University, 031593 Bucharest, Romania
| | - Andreea-Elena Scheau
- Department of Radiology and Medical Imaging, Fundeni Clinical Institute, 022328 Bucharest, Romania
| | - Ioana Anca Badarau
- Department of Physiology, The “Carol Davila” University of Medicine and Pharmacy, 8 Eroii Sanitari Boulevard, 050474 Bucharest, Romania
| | - Andreea Cristiana Didilescu
- Department of Embryology, Faculty of Dentistry, The “Carol Davila” University of Medicine and Pharmacy, 8 Eroii Sanitari Boulevard, 050474 Bucharest, Romania
| | - Constantin Caruntu
- Department of Physiology, The “Carol Davila” University of Medicine and Pharmacy, 8 Eroii Sanitari Boulevard, 050474 Bucharest, Romania
- Department of Dermatology, “Prof. N.C. Paulescu” National Institute of Diabetes, Nutrition and Metabolic Diseases, 011233 Bucharest, Romania
| | - Cristian Scheau
- Department of Physiology, The “Carol Davila” University of Medicine and Pharmacy, 8 Eroii Sanitari Boulevard, 050474 Bucharest, Romania
- Department of Radiology and Medical Imaging, “Foisor” Clinical Hospital of Orthopaedics, Traumatology and Osteoarticular TB, 021382 Bucharest, Romania
| |
Collapse
|
12
|
Liang H, Zhang H, Chen B, Yang L, Xu R, Duan S, Cai Z. 3D printing technology combined with personalized plates for complex distal intra-articular fractures of the trimalleolar ankle. Sci Rep 2023; 13:22667. [PMID: 38114629 PMCID: PMC10730506 DOI: 10.1038/s41598-023-49515-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2023] [Accepted: 12/08/2023] [Indexed: 12/21/2023] Open
Abstract
This study investigated the effectiveness of 3D printing technology in combination with personalized custom-made steel plates in the treatment of complex distal intra-articular trimalleolar fractures, with the aim of providing a new approach to improve ankle joint function in patients. The 48 patients with complex distal intra-articular trimalleolar fractures included in the study were randomly divided into two groups: the personalized custom-made steel plate group (n = 24) and the conventional steel plate group (n = 24). A comparison was made between the two groups in terms of preoperative preparation time, hospitalization duration, surgical time, fracture reduction and internal fixation time, intraoperative fluoroscopy instances, surgical incision length, fracture healing time, follow-up duration, degree of fracture reduction, ankle joint functional recovery, and the occurrence of complications. The personalized steel plate group exhibited longer preoperative preparation time and hospitalization duration compared to the conventional steel plate group (p < 0.001). However, the personalized steel plate group demonstrated significantly shorter surgical duration, time for fracture reduction and internal fixation, reduced intraoperative fluoroscopy frequency, and a shorter overall surgical incision length (p < 0.001). Both groups displayed similar fracture healing times and follow-up durations (p > 0.05). The personalized steel plate group showed a higher rate of successful fracture reduction (87.5% vs. 79.2%, p > 0.05) and a lower incidence of complications (8.3% vs. 20.8%, p = 0.22), although these differences did not reach statistical significance. Furthermore, the personalized steel plate group exhibited superior ankle joint function scores during follow-up compared to the conventional steel plate group (p < 0.05). By utilizing 3D printing technology in conjunction with personalized custom-made steel plates, personalized treatment plans are provided for patients with complex comminuted tri-malleolar ankle fractures, enabling safer, more efficient, and satisfactory orthopedic surgeries.
Collapse
Affiliation(s)
- Hairui Liang
- Department of Orthopedics Surgery, Central Hospital Afliated to Shenyang Medical College, 5 Nanqi West Road, Shenyang, 110075, Liaoning, China
| | - He Zhang
- Department of Orthopedics Surgery, Central Hospital Afliated to Shenyang Medical College, 5 Nanqi West Road, Shenyang, 110075, Liaoning, China
| | - Beibei Chen
- Department of Orthopedics Surgery, Central Hospital Afliated to Shenyang Medical College, 5 Nanqi West Road, Shenyang, 110075, Liaoning, China
| | - Lei Yang
- School of Pharmacy, Inner Mongolia Medical University, 5 Xinhua Street, Hohhot, 010107, Inner Mongolia Autonomous Region, China
| | - Rongda Xu
- Department of Orthopedics Surgery, Central Hospital Afliated to Shenyang Medical College, 5 Nanqi West Road, Shenyang, 110075, Liaoning, China
| | - Siyu Duan
- Department of Orthopedics Surgery, Central Hospital Afliated to Shenyang Medical College, 5 Nanqi West Road, Shenyang, 110075, Liaoning, China
| | - Zhencun Cai
- Department of Orthopedics Surgery, Central Hospital Afliated to Shenyang Medical College, 5 Nanqi West Road, Shenyang, 110075, Liaoning, China.
| |
Collapse
|
13
|
Cheng KY, Gupta P, Kanniyappan H, Zahurullah H, Sun Y, Alhamad M, Mathew MT. Survivability of Titanium Implant Materials: In Vitro Simulated Inflammatory and Infectious Environment. Ann Biomed Eng 2023; 51:2749-2761. [PMID: 37530907 PMCID: PMC10834857 DOI: 10.1007/s10439-023-03330-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 07/22/2023] [Indexed: 08/03/2023]
Abstract
Titanium-based implants utilized in total joint arthroplasties could restore primary musculoskeletal function to patients suffering from osteoarthritis and other conditions. Implants are susceptible to failure stemming from aseptic loosening and infection at the joint site, eventually requiring revision surgery. We hypothesized that there might be a feedback loop by which metal degradation particles and ions released from the implant decrease cell viability and increase immune response, thereby creating biochemical conditions that increase the corrosion rate and release more metal ions. This study focused on the synergistic process through cell viability assays and electrochemical tests. From the results, inflammatory conditions from ion release resulting in cell death would further increase the corrosion rate at the metal implant site. The synergistic interaction in the implant surroundings in which infectious conditions produce Ti ions that contribute to more infection, creating a potential cycle of accelerating corrosion.
Collapse
Affiliation(s)
- Kai Yuan Cheng
- Regenerative Medicine and Disability Research Lab, University of Illinois College of Medicine, Rockford, IL, USA
| | - Puranjay Gupta
- Regenerative Medicine and Disability Research Lab, University of Illinois College of Medicine, Rockford, IL, USA
| | - Hemalatha Kanniyappan
- Regenerative Medicine and Disability Research Lab, University of Illinois College of Medicine, Rockford, IL, USA
| | - Hamza Zahurullah
- Regenerative Medicine and Disability Research Lab, University of Illinois College of Medicine, Rockford, IL, USA
| | - Yani Sun
- Department of Biomedical Engineering, College of Engineering, University of Illinois , Chicago, IL, USA
| | - Mostafa Alhamad
- Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, Chicago, IL, USA
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Ad Dammām, Saudi Arabia
| | - Mathew T Mathew
- Regenerative Medicine and Disability Research Lab, University of Illinois College of Medicine, Rockford, IL, USA.
- Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, Chicago, IL, USA.
- Department of Biomedical Engineering, College of Engineering, University of Illinois , Chicago, IL, USA.
| |
Collapse
|
14
|
Chandhanayingyong C, Thanapipatsiri P, Pairojboriboon S, Luenam S, Hongsaprabhas C, Charoenlap C, Wattanapaiboon K, Asavamongkolkul A, Tharmviboonsri T, Phimolsarnti R. What Are the MSTS Scores and Complications Associated With the Use of Three-dimensional Printed, Custom-made Prostheses in Patients Who Had Resection of Tumors of the Hand and Foot? Clin Orthop Relat Res 2023; 481:2223-2235. [PMID: 37339168 PMCID: PMC10566964 DOI: 10.1097/corr.0000000000002730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Revised: 03/10/2023] [Accepted: 05/17/2023] [Indexed: 06/22/2023]
Abstract
BACKGROUND There are a few good options for restoring bone defects in the hand and foot. 3D-printed implants have been used in the pelvis and elsewhere, but to our knowledge, they have not been evaluated in the hand and foot. The functional outcome, complications, and longevity of 3D-printed prostheses in small bones are not well known. QUESTIONS/PURPOSES (1) What are the functional outcomes of patients with hand or foot tumors who were treated with tumor resection and reconstruction with a 3D-printed custom prosthesis? (2) What complications are associated with using these prostheses? (3) What is the 5-year Kaplan-Meier cumulative incidence of implant breakage and reoperation? METHODS Between January 2017 and October 2020, we treated 276 patients who had tumors of the hands or feet. Of those, we considered as potentially eligible patients who might have extensive loss in their joint that could not be fixed with a bone graft, cement, or any prostheses available on the market. Based on this, 93 patients were eligible; a further 77 were excluded because they received nonoperative treatment such as chemoradiation, resection without reconstruction, reconstruction using other materials, or ray amputation; another three were lost before the minimum study follow-up of 2 years and two had incomplete datasets, leaving 11 for analysis in this retrospective study. There were seven women and four men. The median age was 29 years (range 11 to 71 years). There were five hand tumors and six tumors of the feet. Tumor types were giant cell tumor of bone (five), chondroblastoma (two), osteosarcoma (two), neuroendocrine tumor (one), and squamous cell carcinoma (one). Margin status after resection was ≥ 1 mm. All patients were followed for a minimum of 24 months. The median follow-up time was 47 months (range 25 to 67 months). Clinical data; function according to the Musculoskeletal Tumor Society, DASH, and American Orthopedic Foot and Ankle Society scores; complications; and survivorship of implants were recorded during follow-up in the clinic, or patients with complete charts and recorded data were interviewed on the telephone by our research associates, orthopaedic oncology fellows, or the surgeons who performed the surgery. The cumulative incidence of implant breakage and reoperation was assessed using a Kaplan-Meier analysis. RESULTS The median Musculoskeletal Tumor Society score was 28 of 30 (range 21 to 30). Seven of 11 patients experienced postoperative complications, primarily including hyperextension deformity and joint stiffness (three patients), joint subluxation (two), aseptic loosening (one), broken stem (one), and broken plate (one), but no infection or local recurrence occurred. Subluxations of the metacarpophalangeal and proximal interphalangeal joints in two patients' hands were caused by the design of the prosthesis without a joint or stem. These prostheses were revised to a second-generation prosthesis with joint and stem, leading to improved dexterity. The cumulative incidence of implant breakage and reoperation in the Kaplan-Meier analysis was 35% (95% CI 6% to 69%) and 29% (95% CI 3% to 66%) at 5 years, respectively. CONCLUSION These preliminary findings suggest that 3D implants may be an option for reconstruction after resections that leave large bone and joint defects in the hand and foot. Although the functional results generally appeared to be good to excellent, complications and reoperations were frequent; thus, we believe this approach could be considered when patients have few or no alternatives other than amputation. Future studies will need to compare this approach to bone grafting or bone cementation. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
Affiliation(s)
| | - Pannin Thanapipatsiri
- Department of Orthopaedic Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Sutipat Pairojboriboon
- Department of Orthopaedics, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand
| | - Suriya Luenam
- Department of Orthopaedics, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand
| | - Chindanai Hongsaprabhas
- Department of Orthopaedics, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Chris Charoenlap
- Department of Orthopaedics, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Komkrich Wattanapaiboon
- Department of Orthopedic Surgery, Queen Savang Vadhana Memorial Hospital, Chonburi, Thailand
| | - Apichat Asavamongkolkul
- Department of Orthopaedic Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Theerawoot Tharmviboonsri
- Department of Orthopaedic Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Rapin Phimolsarnti
- Department of Orthopaedic Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| |
Collapse
|
15
|
Milivojevic M, Chen K, Radovanovic Z, Petrovic R, Dimitrijevic-Brankovic S, Kojic V, Markovic D, Janackovic D. Enhanced antimicrobial properties and bioactivity of 3D-printed titanium scaffolds by multilayer bioceramic coating for large bone defects. Biomed Mater 2023; 18:065020. [PMID: 37827161 DOI: 10.1088/1748-605x/ad02d2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 10/12/2023] [Indexed: 10/14/2023]
Abstract
The restoration of large bone defects caused by trauma, tumor resection, or infection is a major clinical problem in orthopedics and dentistry because postoperative infections, corrosion, and limited osteointegration of metal implants can lead to loosening of the implant. The aim of this study was to improve the surface properties of a 3D-printed (electron beam melting) Ti6Al4V-based macroporous scaffold by multilayer coating with bioactive silicate glasses (BAGs) and hydroxyapatite doped with a silver (AgHAP) or AgHAP additionally sonochemically modified with ZnO (ZnO-AgHAP). The coated scaffolds AgHAP_BAGs_Ti and ZnO-AgHAP_BAGs_Ti enhanced cytocompatibility in L929 and MRC5 cell lines and expressed bioactivity in simulated body fluid. A lower release of vanadium ions in coated samples compared to bare Ti scaffold indicates decreased dissolution of Ti alloy in coated samples. The coated samples reduced growth ofEscherichia coliandStaphylococcus aureusfor 4-6 orders of magnitude. Therefore, the 3D-printed Ti-based scaffolds coated with BAGs and (ZnO-)AgHAP have great potential for application as a multifunctional implant with antibacterial properties for the restoration of defects in load-bearing bones.
Collapse
Affiliation(s)
- Marija Milivojevic
- Innovation Center of the Faculty of Technology and Metallurgy in Belgrade Ltd, Belgrade, Serbia
| | - Ke Chen
- School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Zeljko Radovanovic
- Innovation Center of the Faculty of Technology and Metallurgy in Belgrade Ltd, Belgrade, Serbia
| | - Rada Petrovic
- Faculty of Technology and Metallurgy, University of Belgrade, Belgrade, Serbia
| | | | - Vesna Kojic
- Faculty of Medicine, Oncology Institute of Vojvodina, University of Novi Sad, Sremska Kamenica, Serbia
| | - Danica Markovic
- Faculty of Veterinary Medicine, University of Belgrade, Belgrade, Serbia
| | - Djordje Janackovic
- Faculty of Technology and Metallurgy, University of Belgrade, Belgrade, Serbia
| |
Collapse
|
16
|
Huang B, Yin Z, Zhou F, Su J. Functional anti-bone tumor biomaterial scaffold: construction and application. J Mater Chem B 2023; 11:8565-8585. [PMID: 37415547 DOI: 10.1039/d3tb00925d] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/08/2023]
Abstract
Bone tumors, including primary bone tumors and bone metastases, have been plagued by poor prognosis for decades. Although most tumor tissue is removed, clinicians are still confronted with the dilemma of eliminating residual cancer cells and regenerating defective bone tissue after surgery. Therefore, functional biomaterial scaffolds are considered to be the ideal candidates to bridge defective tissues and restrain cancer recurrence. Through functionalized structural modifications or coupled therapeutic agents, they provide sufficient mechanical strength and osteoinductive effects while eliminating cancer cells. Numerous novel approaches such as photodynamic, photothermal, drug-conjugated, and immune adjuvant-assisted therapies have exhibited remarkable efficacy against tumors while exhibiting low immunogenicity. This review summarizes the progress of research on biomaterial scaffolds based on different functionalization strategies in bone tumors. We also discuss the feasibility and advantages of the combined application of multiple functionalization strategies. Finally, potential obstacles to the clinical translation of anti-tumor bone bioscaffolds are highlighted. This review will provide valuable references for future advanced biomaterial scaffold design and clinical bone tumor therapy.
Collapse
Affiliation(s)
- Biaotong Huang
- Institute of Translational Medicine, Shanghai University, Shanghai, 200444, China.
- Organoid Research Center, Shanghai University, Shanghai, 200444, China
- Wenzhou Institute of Shanghai University, Wenzhou 325000, China
| | - Zhifeng Yin
- Department of Orthopedics, Shanghai Zhongye Hospital, Shanghai, 200444, China
| | - Fengjin Zhou
- Department of Orthopedics, Honghui Hospital, Xi'an Jiao Tong University, Xi'an, 710000, China.
| | - Jiacan Su
- Institute of Translational Medicine, Shanghai University, Shanghai, 200444, China.
- Organoid Research Center, Shanghai University, Shanghai, 200444, China
| |
Collapse
|
17
|
Murphy B, Baez J, Morris MA. Characterising Hydroxyapatite Deposited from Solution onto Novel Substrates: Growth Mechanism and Physical Properties. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2483. [PMID: 37686991 PMCID: PMC10489777 DOI: 10.3390/nano13172483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 08/29/2023] [Accepted: 09/01/2023] [Indexed: 09/10/2023]
Abstract
Whilst titanium, stainless steel, and cobalt-chrome alloys are the most common materials for use in orthopaedic implant devices, there are significant advantages in moving to alternative non-metallic substrates. Substrates such as polymers may have advantageous mechanical biological properties whilst other substrates may bring unique capability. A key challenge in the use of non-metal products is producing substrates which can be modified to allow the formation of well-adhered hydroxyapatite films which promote osteointegration and have other beneficial properties. In this work, we aim to develop methodology for the growth of hydroxyapatite films on surfaces other than bulk metallic parts using a wet chemical coating process, and we provide a detailed characterisation of the coatings. In this study, hydroxyapatite is grown from saturated solutions onto thin titanium films and silicon substrates and compared to results from titanium alloy substrates. The coating process efficacy is shown to be dependent on substrate roughness, hydrophilicity, and activation. The mechanism of the hydroxyapatite growth is investigated in terms of initial attachment and morphological development using SEM and XPS analysis. XPS analysis reveals the exact chemical state of the hydroxyapatite compositional elements of Ca, P, and O. The characterisation of grown hydroxyapatite layers by XRD reveals that the hydroxyapatite forms from amorphous phases, displaying preferential crystal growth along the [002] direction, with TEM imagery confirming polycrystalline pockets amid an amorphous matrix. SEM-EDX and FTIR confirmed the presence of hydroxyapatite phases through elemental atomic weight percentages and bond assignment. All data are collated and reviewed for the different substrates. The results demonstrate that once hydroxyapatite seeds, it crystallises in the same manner as bulk titanium whether that be on a titanium or silicon substrate. These data suggest that a range of substrates may be coated using this facile hydroxyapatite deposition technique, just broadening the choice of substrate for a particular function.
Collapse
Affiliation(s)
- Bríd Murphy
- Advanced Materials & Bioengineering Research Centre (AMBER), Trinity College Dublin, Dublin 2, D02 CP49 Dublin, Ireland;
- School of Chemistry, Trinity College Dublin, Dublin 2, D02 PN40 Dublin, Ireland
| | - Jhonattan Baez
- Advanced Materials & Bioengineering Research Centre (AMBER), Trinity College Dublin, Dublin 2, D02 CP49 Dublin, Ireland;
- School of Chemistry, Trinity College Dublin, Dublin 2, D02 PN40 Dublin, Ireland
| | - Mick A. Morris
- Advanced Materials & Bioengineering Research Centre (AMBER), Trinity College Dublin, Dublin 2, D02 CP49 Dublin, Ireland;
- School of Chemistry, Trinity College Dublin, Dublin 2, D02 PN40 Dublin, Ireland
| |
Collapse
|
18
|
Yang S, Jiang W, Ma X, Wang Z, Sah RL, Wang J, Sun Y. Nanoscale Morphologies on the Surface of 3D-Printed Titanium Implants for Improved Osseointegration: A Systematic Review of the Literature. Int J Nanomedicine 2023; 18:4171-4191. [PMID: 37525692 PMCID: PMC10387278 DOI: 10.2147/ijn.s409033] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Accepted: 07/10/2023] [Indexed: 08/02/2023] Open
Abstract
Three-dimensional (3D) printing is serving as the most promising approach to fabricate personalized titanium (Ti) implants for the precise treatment of complex bone defects. However, the bio-inert nature of Ti material limits its capability for rapid osseointegration and thus influences the implant lifetime in vivo. Despite the macroscale porosity for promoting osseointegration, 3D-printed Ti implant surface morphologies at the nanoscale have gained considerable attention for their potential to improve specific outcomes. To evaluate the influence of nanoscale surface morphologies on osseointegration outcomes of 3D-printed Ti implants and discuss the available strategies, we systematically searched evidence according to the PRISMA on PubMed, Embase, Web of Science, and Cochrane (until June 2022). The inclusion criteria were in vivo (animal) studies reporting the osseointegration outcomes of nanoscale morphologies on the surface of 3D-printed Ti implants. The risk of bias (RoB) was assessed using the Systematic Review Centre for Laboratory Animal Experimentation (SYRCLE's) tool. The quality of the studies was evaluated using the Animal Research: Reporting of In Vivo Experiments (ARRIVE) guidelines. (PROSPERO: CRD42022334222). Out of 119 retrieved articles, 9 studies met the inclusion criteria. The evidence suggests that irregular nano-texture, nanodots and nanotubes with a diameter of 40-105nm on the surface of porous/solid 3D-printed Ti implants result in better osseointegration and vertical bone ingrowth compared to the untreated/polished ones by significantly promoting cell adhesion, matrix mineralization, and osteogenic differentiation through increasing integrin expression. The RoB was low in 41.1% of items, unclear in 53.3%, and high in 5.6%. The quality of the studies achieved a mean score of 17.67. Our study demonstrates that nanostructures with specific controlled properties on the surface of 3D-printed Ti implants improve their osseointegration. However, given the small number of studies, the variability in experimental designs, and lack of reporting across studies, the results should be interpreted with caution.
Collapse
Affiliation(s)
- Shiyan Yang
- Orthopedic Medical Center, the Second Hospital of Jilin University, Changchun, Jilin, 130000, People's Republic of China
| | - Weibo Jiang
- Orthopedic Medical Center, the Second Hospital of Jilin University, Changchun, Jilin, 130000, People's Republic of China
| | - Xiao Ma
- Department of Orthopedics, the China-Japan Union Hospital of Jilin University, Changchun, Jilin, 130000, People's Republic of China
| | - Zuobin Wang
- International Research Centre for Nano Handling and Manufacturing of China, Changchun University of Science and Technology, Changchun, Jilin, 130000, People's Republic of China
| | - Robert L Sah
- Department of Bioengineering, University of California-San Diego, La Jolla, CA, 92037, USA
- Center for Musculoskeletal Research, Institute of Engineering in Medicine, University of California-San Diego, La Jolla, CA, 92037, USA
| | - Jincheng Wang
- Orthopedic Medical Center, the Second Hospital of Jilin University, Changchun, Jilin, 130000, People's Republic of China
| | - Yang Sun
- Orthopedic Medical Center, the Second Hospital of Jilin University, Changchun, Jilin, 130000, People's Republic of China
| |
Collapse
|
19
|
Yuste I, Luciano FC, Anaya BJ, Sanz-Ruiz P, Ribed-Sánchez A, González-Burgos E, Serrano DR. Engineering 3D-Printed Advanced Healthcare Materials for Periprosthetic Joint Infections. Antibiotics (Basel) 2023; 12:1229. [PMID: 37627649 PMCID: PMC10451995 DOI: 10.3390/antibiotics12081229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 07/12/2023] [Accepted: 07/18/2023] [Indexed: 08/27/2023] Open
Abstract
The use of additive manufacturing or 3D printing in biomedicine has experienced fast growth in the last few years, becoming a promising tool in pharmaceutical development and manufacturing, especially in parenteral formulations and implantable drug delivery systems (IDDSs). Periprosthetic joint infections (PJIs) are a common complication in arthroplasties, with a prevalence of over 4%. There is still no treatment that fully covers the need for preventing and treating biofilm formation. However, 3D printing plays a major role in the development of novel therapies for PJIs. This review will provide a deep understanding of the different approaches based on 3D-printing techniques for the current management and prophylaxis of PJIs. The two main strategies are focused on IDDSs that are loaded or coated with antimicrobials, commonly in combination with bone regeneration agents and 3D-printed orthopedic implants with modified surfaces and antimicrobial properties. The wide variety of printing methods and materials have allowed for the manufacture of IDDSs that are perfectly adjusted to patients' physiognomy, with different drug release profiles, geometries, and inner and outer architectures, and are fully individualized, targeting specific pathogens. Although these novel treatments are demonstrating promising results, in vivo studies and clinical trials are required for their translation from the bench to the market.
Collapse
Affiliation(s)
- Iván Yuste
- Pharmaceutics and Food Technology Department, Faculty of Pharmacy, Universidad Complutense de Madrid (UCM), 28040 Madrid, Spain; (I.Y.); (F.C.L.); (B.J.A.); (D.R.S.)
| | - Francis C. Luciano
- Pharmaceutics and Food Technology Department, Faculty of Pharmacy, Universidad Complutense de Madrid (UCM), 28040 Madrid, Spain; (I.Y.); (F.C.L.); (B.J.A.); (D.R.S.)
| | - Brayan J. Anaya
- Pharmaceutics and Food Technology Department, Faculty of Pharmacy, Universidad Complutense de Madrid (UCM), 28040 Madrid, Spain; (I.Y.); (F.C.L.); (B.J.A.); (D.R.S.)
| | - Pablo Sanz-Ruiz
- Orthopaedic and Trauma Department, Hospital General Universitario Gregorio Marañón, 28029 Madrid, Spain;
- Department of Surgery, Faculty of Medicine, Universidad Complutense de Madrid (UCM), 28040 Madrid, Spain
| | - Almudena Ribed-Sánchez
- Hospital Pharmacy Unit, Hospital General Universitario Gregorio Marañón, 28029 Madrid, Spain;
| | - Elena González-Burgos
- Department of Pharmacology, Pharmacognosy and Botany, Faculty of Pharmacy, Universidad Complutense de Madrid (UCM), 28040 Madrid, Spain
| | - Dolores R. Serrano
- Pharmaceutics and Food Technology Department, Faculty of Pharmacy, Universidad Complutense de Madrid (UCM), 28040 Madrid, Spain; (I.Y.); (F.C.L.); (B.J.A.); (D.R.S.)
- Instituto Universitario de Farmacia Industrial, Faculty of Pharmacy, Universidad Complutense de Madrid (UCM), 28040 Madrid, Spain
| |
Collapse
|
20
|
Berger MB, Cohen DJ, Snyder K, Sions J, Boyan BD, Schwartz Z. Bone marrow stromal cells are sensitive to discrete surface alterations in build and post-build modifications of bioinspired Ti6Al4V 3D-printed in vitro testing constructs. J Biomed Mater Res B Appl Biomater 2023; 111:829-845. [PMID: 36372947 DOI: 10.1002/jbm.b.35194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 10/13/2022] [Accepted: 10/29/2022] [Indexed: 11/16/2022]
Abstract
Current standards in bone-facing implant fabrication by metal 3D (M3D) printing require post-manufacturing modifications to create distinct surface properties and create implant microenvironments that promote osseointegration. However, the biological consequences of build parameters and surface modifications are not well understood. This study evaluated the relative contributions of build parameters and post-manufacturing modification techniques to cell responses that impact osseointegration in vivo. Biomimetic testing constructs were created by using a M3D printer with standard titanium-aluminum-vanadium (Ti6Al4V) print parameters. These constructs were treated by either grit-blasting and acid-etching (GB + AE) or GB + AE followed by hot isostatic pressure (HIP) (GB + AE, HIP). Next, nine constructs were created by using a M3D printer with three build parameters: (1) standard, (2) increased hatch spacing, and (3) no infill, and additional contour trace. Each build type was further processed by either GB + AE, or HIP, or a combination of HIP treatment followed by GB + AE (GB + AE, HIP). Resulting constructs were assessed by SEM, micro-CT, optical profilometry, XPS, and mechanical compression. Cellular response was determined by culturing human bone marrow stromal cells (MSCs) for 7 days. Surface topography differed depending on processing method; HIP created micro-/nano-ridge like structures and GB + AE created micro-pits and nano-scale texture. Micro-CT showed decreases in closed pore number and closed porosity after HIP treatment in the third build parameter constructs. Compressive moduli were similar for all constructs. All constructs exhibited ability to differentiate MSCs into osteoblasts. MSCs responded best to micro-/nano-structures created by final post-processing by GB + AE, increasing OCN, OPG, VEGFA, latent TGFβ1, IL4, and IL10. Collectively these data demonstrate that M3D-printed constructs can be readily manufactured with distinct architectures based on the print parameters and post-build modifications. MSCs are sensitive to discrete surface topographical differences that may not show up in qualitative assessments of surface properties and respond by altering local factor production. These factors are vital for osseointegration after implant insertion, especially in patients with compromised bone qualities.
Collapse
Affiliation(s)
- Michael B Berger
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, Virginia, USA
| | - D Joshua Cohen
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Kyle Snyder
- Commonwealth Center for Advanced Manufacturing, Virginia, USA
| | - John Sions
- Commonwealth Center for Advanced Manufacturing, Virginia, USA
| | - Barbara D Boyan
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, Virginia, USA.,Wallace H. Coulter Department of Biomedical Engineering at the Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA
| | - Zvi Schwartz
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, Virginia, USA.,Department of Periodontology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| |
Collapse
|
21
|
Liu J, Wang K, Li X, Zhang X, Gong X, Zhu Y, Ren Z, Zhang B, Cheng J. Biocompatibility and osseointegration properties of a novel high strength and low modulus β- Ti10Mo6Zr4Sn3Nb alloy. Front Bioeng Biotechnol 2023; 11:1127929. [PMID: 36865033 PMCID: PMC9972097 DOI: 10.3389/fbioe.2023.1127929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 02/03/2023] [Indexed: 02/12/2023] Open
Abstract
Introduction: Ti6Al4V titanium alloy is widely used in producing orthopedic and maxillofacial implants, but drawbacks include high elastic modulus, poor osseointegration performance, and toxic elements. A new medical titanium alloy material with better comprehensive performance is urgently needed in the clinic. Methods: Ti10Mo6Zr4Sn3Nb titanium alloy (referred to as Ti-B12) is a unique medical ß titanium alloy material developed by us. The mechanical properties of Ti-B12 depict that it has advantages, such as high strength, low elastic modulus, and fatigue resistance. In our study, the biocompatibility and osseointegration properties of Ti-B12 titanium alloy are further studied to provide theoretical guidance for its clinical transformation. Results and Discussion: The titanium alloy Ti-B12 displays no significant effect on MC3T3-E1 cell morphology, proliferation, or apoptosis in vitro. Neither Ti-B12 titanium alloy nor Ti6Al4V titanium alloy depicts a significant difference (p > 0.05); Ti-B12 material extract injected into the abdominal cavity of mice does not cause acute systemic toxicity. The skin irritation test and intradermal irritation test reveal that Ti-B12 does not cause skin allergic reactions in rabbits. Compared to Ti6Al4V, Ti-B12 titanium alloy material has more advantages in promoting osteoblast adhesion and ALP secretion (p < 0.05). Although there is no significant difference in OCN and Runx2 gene expression between the three groups on the 7th and 14th days of differentiation induction (p > 0.05), the expression of Ti-B12 group is higher than that of Ti6Al4V group and blank control group. Furthermore, the rabbit in vivo test present that 3 months after the material is implanted in the lateral epicondyle of the rabbit femur, the Ti-B12 material fuses with the surrounding bone without connective tissue wrapping. This study confirms that the new β-titanium alloy Ti-B12 not only has low toxicity and does not cause rejection reaction but also has better osseointegration performance than the traditional titanium alloy Ti6Al4V. Therefore, Ti-B12 material is expected to be further promoted in clinical practice.
Collapse
Affiliation(s)
- Jiantao Liu
- Department of Orthopedics, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, Shaanxi, China,Xi’an Jiaotong University, Xi’an, Shaanxi, China,*Correspondence: Jiantao Liu, ; Jun Cheng,
| | - Kao Wang
- Medical School of Yan’an University, Yan’an, Shaanxi, China
| | - Xingyuan Li
- Xi’an Jiaotong University, Xi’an, Shaanxi, China
| | - Xiwei Zhang
- Xi’an Jiaotong University, Xi’an, Shaanxi, China
| | - Xi Gong
- Xi’an Jiaotong University, Xi’an, Shaanxi, China
| | - Yihan Zhu
- Xi’an Jiaotong University, Xi’an, Shaanxi, China
| | - Zhiwei Ren
- Department of Orthopedics, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, Shaanxi, China
| | - Bin Zhang
- Institute of Translational Medicine, Shenzhen Second People’s Hospital, Shenzhen, China
| | - Jun Cheng
- Northwest Institute for Nonferrous Metal Research, Shaanxi Key Laboratory of Biomedical Metal Materials, Xi’an, China,*Correspondence: Jiantao Liu, ; Jun Cheng,
| |
Collapse
|
22
|
Wang X, Guo Q, He Y, Geng X, Wang C, Li Y, Li Z, Wang C, Qiu D, Tian H. A pH-neutral bioactive glass coated 3D-printed porous Ti6Al4V scaffold with enhanced osseointegration. J Mater Chem B 2023; 11:1203-1212. [PMID: 36515141 DOI: 10.1039/d2tb02129c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
Osseointegration is vital for the success of non-degradable implants like those made of titanium alloys. In order to promote osseointegration, implants are made porous, providing space for bone ingrowth. Despite extensive optimization of the pore geometry and porosity, bone ingrowth into implants is still marginal; further modification to promote bone ingrowth as well as osseointegration becomes paramount. In this study, a pH neutral bioactive glass with the composition of 10.8% P2O5-54.2% SiO2-35% CaO (mol%; hereinafter referred to as PSC) was successfully coated on 3D-printed porous Ti6Al4V scaffolds using an in situ sol-gel method. This PSC coating is strongly bonded to the substrate and quickly induces the formation of hydroxyapatite on the scaffold surface upon contact with body fluid. In vitro, the PSC-coated Ti6Al4V scaffolds showed superior biocompatibility, cell proliferation promotion, cell adhesion, osteogenic differentiation and mineralization compared to their bare counterparts, implying better osseointegration. In vivo experiments confirmed this expectation; after being implanted, the coated scaffolds had more bone ingrowth and osseointegration, and consequently, higher push-out strength was achieved, proving the validity of the proposed concept in this study. In conclusion, PSC coating on 3D-printed porous Ti6Al4V scaffolds can improve osteogenesis, bone ingrowth, and osseointegration. Together with the versatility of this in situ sol-gel coating method, titanium alloy implants with better biological performances may be developed for immediate clinical applications.
Collapse
Affiliation(s)
- Xinguang Wang
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, China. .,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, China
| | - Qirui Guo
- Beijing National Laboratory for Molecular Sciences, CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, China. .,University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Yizhen He
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, China. .,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, China
| | - Xiao Geng
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, China. .,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, China
| | - Cheng Wang
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, China. .,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, China
| | - Yang Li
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, China. .,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, China
| | - Zijian Li
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, China. .,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, China
| | - Caimei Wang
- Beijing 3D Printing Orthopedic Application Engineering Technology Research Center, Beijing, 102200, China
| | - Dong Qiu
- Beijing National Laboratory for Molecular Sciences, CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, China. .,University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Hua Tian
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, China. .,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, China
| |
Collapse
|
23
|
Li W, Wang Y, Yang X, Xie Q, Wang C. Comparison of bone ingrowth between two porous titanium alloy rods with biogenic lamellar structures and diamond crystal lattice on femoral condyles in rabbits. Biochem Biophys Res Commun 2023; 641:155-161. [PMID: 36527750 DOI: 10.1016/j.bbrc.2022.12.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 11/24/2022] [Accepted: 12/11/2022] [Indexed: 12/15/2022]
Abstract
PURPOSE The comparison of bone ingrowth between two types of porous titanium alloy rods with different micro-architectures including diamond crystal lattice (Re-rod) and biogenic lamellar configurations (Bi-rod) on femoral condyles was investigated in this study. METHODS Twelve rabbits were used. Re-rod (Re-rod group) and Bi-rod (Bi-rod group) were implanted randomly in femoral condyles of each rabbits respectively. Bone ingrowth of these two rods were investigated and compared. 4 and 12 weeks after the operation, X-ray, micro-CT and histological examinations were performed. RESULTS No femoral condyle fracture and rod defluxion in the two groups was noted in the X-ray images during the observation period. Micro-CT images showed that all metal trabeculae in the Bi-rod group were covered by new bone at 4 and 12 weeks, whereas partial metal trabeculae in the Re-rod group were still uncovered at 12 weeks. Histological images showed that there was new bone growth in the centre and periphery of Bi-rods at 4 and 12 weeks, and there were several areas without new bone ingrowth at 4 and 12 weeks in the centre of Re-rods. In micro-CT analysis, the bone volume to total volume (BV/TV) of the volume of interest (VOI) of the Bi-rod group was higher than in the Re-rod group [(0.0794 ± 0.0021) % Vs (0.0521 ± 0.0032) % and (0.0875 ± 0.0039) % Vs (0.0702 ± 0.0028) % respectively, P < 0.05] at 4 weeks and 12 weeks. Whereas, the mean trabecular thickness (Tb.Th) values of VOI between the two groups were not significantly statistically different at 4 and 12 weeks. In histological analysis, the BV/TV of the VOI of the Bi-rod group was higher than in the Re-rod group [(0.0624 ± 0.0021) % Vs (0.0435 ± 0.0028) % and (0.0675 ± 0.0024) % Vs (0.0476 ± 0.0031) % respectively, P < 0.05] at 4 weeks and 12 weeks. CONCLUSION These results showed that Bi-rods got better bone ingrowth in femoral condyles of rabbits compared with Re-rods.
Collapse
Affiliation(s)
- Wei Li
- Medical College, Southwest Jiaotong University, Chengdu, Sichuan, 610031, China; Department of Orthopaedics, The General Hospital of Western Theater Command, Chengdu, Sichuan, 610083, China
| | - Yu Wang
- Department of Information, The General Hospital of Western Theater Command, Chengdu, Sichuan, 610083, China
| | - Xinglan Yang
- Clinic of Military Patients, The General Hospital of Western Theater Command, Chengdu, Sichuan, 610083, China
| | - Qingyun Xie
- Medical College, Southwest Jiaotong University, Chengdu, Sichuan, 610031, China; Department of Orthopaedics, The General Hospital of Western Theater Command, Chengdu, Sichuan, 610083, China.
| | - Cairu Wang
- Medical College, Southwest Jiaotong University, Chengdu, Sichuan, 610031, China; Department of Orthopaedics, The General Hospital of Western Theater Command, Chengdu, Sichuan, 610083, China.
| |
Collapse
|
24
|
Ma R, Liu Q, Zhou L, Wang L. High porosity 3D printed titanium mesh allows better bone regeneration. BMC Oral Health 2023; 23:6. [PMID: 36604677 PMCID: PMC9817245 DOI: 10.1186/s12903-023-02717-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Accepted: 01/04/2023] [Indexed: 01/07/2023] Open
Abstract
BACKGROUND Most patients with insufficient bone mass suffer from severe horizontal or vertical bone defects in oral implant surgery. The purpose of this study was to compare the bone regeneration effects of titanium meshes with different porosity in the treatment of bone defects. METHODS Nine beagle dogs were equally divided into three groups based on execution time. Three months after the extraction of the first to fourth premolars of the mandible, three bone defects were randomly made in the mandible. Bone particles and three kinds of three-dimensional (3D) printed titanium nets with different porosities (low porosity group (LP), 55%; medium porosity group (MP), 62%; and high porosity group (HP), 68%) were replanted in situ. The beagles were killed 4, 8, and 12 weeks after surgery. Formalin-fixed specimens were embedded in acrylic resin. The specimens were stained with micro-CT, basic fuchsin staining, and toluidine blue staining. RESULTS Micro-CT analysis showed that the trabecular thickness, trabecular number, and bone volume fraction of the HP group were higher than those of the other two groups. Moreover, the trabecular separation of the HP group decreased slightly and was lower than that of the MP and LP groups. Histological staining analysis showed that the trabecular number in the HP group was higher than in the other two groups at 8 and 12 weeks, and the bone volume fraction of the HP was higher than that in the other two groups at 12 weeks. Moreover, the trabecular thickness of the MP was higher than that of the LP group at 12 weeks and the trabecular separation was lower in the HP group at 4 and 8 weeks. The differences were statistically significant (p < 0.05). CONCLUSION A 3D printed titanium mesh with HP in a certain range may have more advantages than a titanium mesh with LP in repairing large bone defects.
Collapse
Affiliation(s)
- Rui Ma
- grid.24696.3f0000 0004 0369 153XDepartment of Dental Implant Centre, Beijing Stomatological Hospital, Capital Medical University, Capital Medical University School of Stomatology, No. 4 Tian Tan Xi Li, Dongcheng District, Beijing, 100050 China ,Beijing Citident Hospital of Stomatology, Beijing, 100032 China
| | - Qian Liu
- Beijing Citident Hospital of Stomatology, Beijing, 100032 China ,Digital Mesh Beijing Technology Co., Ltd, Beijing, 101312 China
| | - Libo Zhou
- grid.411849.10000 0000 8714 7179Heilongjiang Key Laboratory of Oral Biomedical Materials and Clinical Application, Experimental Center for Stomatology Engineering, Jiamusi University Affiliated Stomatological Hospital, Jiamusi, 154000 Jiamusi China
| | - Lingxiao Wang
- grid.24696.3f0000 0004 0369 153XDepartment of Dental Implant Centre, Beijing Stomatological Hospital, Capital Medical University, Capital Medical University School of Stomatology, No. 4 Tian Tan Xi Li, Dongcheng District, Beijing, 100050 China
| |
Collapse
|
25
|
Hu P, Du S, Wei F, Zhai S, Zhou H, Liu X, Liu Z. Reconstruction after resection of C2 vertebral tumors: A comparative study of 3D-printed vertebral body versus titanium mesh. Front Oncol 2022; 12:1065303. [PMID: 36601475 PMCID: PMC9806260 DOI: 10.3389/fonc.2022.1065303] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Accepted: 11/30/2022] [Indexed: 12/23/2022] Open
Abstract
Background Surgical resection of C2 vertebral tumors is challenging owing to the complex anatomy of C2 vertebrae and the challenges to surgical exposure. Various surgical approaches are available, but some are associated with excessively high risks of complications. An additional challenge is reconstruction of the upper cervical spine following surgery. In the last decade, additive-manufacturing personalized artificial vertebral bodies (AVBs) have been introduced for the repair of large, irregular bony defects; however, their use and efficacy in upper cervical surgery have not been well addressed. Therefore, in this study, we compared instrumented fixation status between patients who underwent conventional titanium mesh reconstruction and those who underwent the same resection but with personalized AVBs. Methods We performed a retrospective comparative study and recruited a single-institution cohort of patients with C2 vertebral tumors. Clinical data and imaging findings were reviewed. Through data processing and comparative analysis, we described and discussed the feasibility and safety of surgical resection and the outcomes of hardware implants. The primary outcome of this study was instrumented fixation status. Results The 31 recruited patients were divided into two groups. There were 13 patients in group A who underwent conventional titanium mesh reconstruction and 18 group B patients who underwent personalized AVBs. All patients underwent staged posterior and anterior surgical procedures. In the cohort, 9.7% achieved total en bloc resection of the tumor, while gross total resection was achieved in the remaining 90.3%. The perioperative complication and mortality rates were 45.2% and 6.5%, respectively. The occurrence of perioperative complications was related to the choice of anterior approach (p < 0.05). Group A had a higher complication rate than group B (p < 0.05). Four patients (4/13, 30.8%) developed hardware problems during the follow-up period; however, this rate was marginally higher than that of group B (1/18, 5.6%). Conclusions Total resection of C2 vertebral tumors was associated with a high risk of perioperative complications. The staged posterior and retropharyngeal approaches are better surgical strategies for C2 tumors. Personalized AVBs can provide a reliable reconstruction outcome, yet minor pitfalls remain that call for further modification.
Collapse
Affiliation(s)
- Panpan Hu
- Department of Orthopedics and Beijing Key Laboratory of Spinal Disease Research, Peking University Third Hospital, Beijing, China
| | - Suiyong Du
- Department of Spine Surgery, 521 Hospital of Norinco Group, Xi’an, China
| | - Feng Wei
- Department of Orthopedics and Beijing Key Laboratory of Spinal Disease Research, Peking University Third Hospital, Beijing, China,*Correspondence: Feng Wei,
| | - Shuheng Zhai
- Department of Orthopedics and Beijing Key Laboratory of Spinal Disease Research, Peking University Third Hospital, Beijing, China
| | - Hua Zhou
- Department of Orthopedics and Beijing Key Laboratory of Spinal Disease Research, Peking University Third Hospital, Beijing, China
| | - Xiaoguang Liu
- Department of Orthopedics and Beijing Key Laboratory of Spinal Disease Research, Peking University Third Hospital, Beijing, China
| | - Zhongjun Liu
- Department of Orthopedics and Beijing Key Laboratory of Spinal Disease Research, Peking University Third Hospital, Beijing, China
| |
Collapse
|
26
|
Chen C, Huang B, Liu Y, Liu F, Lee IS. Functional engineering strategies of 3D printed implants for hard tissue replacement. Regen Biomater 2022; 10:rbac094. [PMID: 36683758 PMCID: PMC9845531 DOI: 10.1093/rb/rbac094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 10/20/2022] [Accepted: 10/27/2022] [Indexed: 11/27/2022] Open
Abstract
Three-dimensional printing technology with the rapid development of printing materials are widely recognized as a promising way to fabricate bioartificial bone tissues. In consideration of the disadvantages of bone substitutes, including poor mechanical properties, lack of vascularization and insufficient osteointegration, functional modification strategies can provide multiple functions and desired characteristics of printing materials, enhance their physicochemical and biological properties in bone tissue engineering. Thus, this review focuses on the advances of functional engineering strategies for 3D printed biomaterials in hard tissue replacement. It is structured as introducing 3D printing technologies, properties of printing materials (metals, ceramics and polymers) and typical functional engineering strategies utilized in the application of bone, cartilage and joint regeneration.
Collapse
Affiliation(s)
- Cen Chen
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, PR China
| | - Bo Huang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, PR China
| | - Yi Liu
- Department of Orthodontics, School of Stomatology, China Medical University, Shenyang 110002, PR China
| | - Fan Liu
- Department of Orthodontics, School of Stomatology, China Medical University, Shenyang 110002, PR China
| | | |
Collapse
|
27
|
Gong X, Zhang A, Han Q, Wang Y, Liu Y, Jiao J, Yue J, Chen H, Luo W, Wang J, Wu M. Biomechanical effects of individualized artificial titanium alloy lamina implantation after laminectomy: A finite element analysis. Front Bioeng Biotechnol 2022; 10:1019510. [DOI: 10.3389/fbioe.2022.1019510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 11/04/2022] [Indexed: 11/19/2022] Open
Abstract
Background and objectives: Laminectomy is a common surgical procedure in spine surgery. However, disruption of the posterior ligamentous complex of the spine may lead to a range of postoperative complications. Artificial lamina as a kind of bionic implant can well restore the posterior spinal structure. In this study, an individualized artificial titanium alloy lamina was designed to reconstruct the posterior spinal structure after laminectomy and explored its biomechanical effects, which could provide a theoretical basis for the clinical application of the artificial lamina.Methods: Three finite element models were constructed, namely the nonlinear and non-homogeneous intact model of the whole lumbar spine, the lumbar decompression alone surgical model, and the artificial lamina implantation surgical model. The range of motion, intradiscal pressure, and annulus fibrosus peak stress were compared between the three models at the surgical and adjacent segments. The stresses of the artificial lamina and fixation screws were also analyzed for the four movement states.Results: Compared with the intact model, the lumbar decompression alone surgical model showed an increase in range of motion, intradiscal pressure, and annulus fibrosus peak stresses at the surgical segment and adjacent segments under all conditions. The artificial lamina implantation surgical model showed an increase in these measurements only in flexion, increasing by 7.5%–22.5%, 7.6%–17.9%, and 6.4%–19.3%, respectively, over the intact model, while there was little difference under other conditions. The peak stresses in both the screw and the artificial lamina were highest in axial rotation, i. e. 46.53 MPa and 53.84 MPa, respectively. Screw stresses were concentrated on the connection between the screw and the artificial lamina, and artificial lamina stresses were concentrated on the spinous root, around the screw hole, and the contact with the vertebral body.Conclusion: An individualized artificial titanium alloy lamina can effectively reduce the range of motion, intradiscal pressure, and annulus fibrosus stress at the surgical segment and adjacent segments. The application of artificial lamina could better preserve the biomechanical properties of the intact lumbar spine and reduce the risk of adjacent segmental disease.
Collapse
|
28
|
An ionic silver coating prevents implant-associated infection by anaerobic bacteria in vitro and in vivo in mice. Sci Rep 2022; 12:18387. [PMID: 36319854 PMCID: PMC9626628 DOI: 10.1038/s41598-022-23322-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 10/29/2022] [Indexed: 11/07/2022] Open
Abstract
Currently, implants are utilized clinically for bone transplant procedures. However, if infectious osteomyelitis occurs at implant sites, removal of bacteria can be challenging. Moreover, altered blood flow at peri-implant infectious sites can create an anaerobic environment, making it more difficult to treat infection with antibiotics. Thus, it would be beneficial if implants could be modified to exhibit antibacterial activity, even in anaerobic conditions. Here, we show antibacterial activity of silver ions coated on titanium rods, even against the anaerobic bacteria Porphyromonas gingivalis (P. gingivalis), both in vitro and in vivo. Specifically, we implanted silver-coated or control uncoated titanium rods along with P. gingivalis in mouse femoral bone BM cavities and observed significantly inhibited P. gingivalis infection with silver-coated compared with non-coated rods, based on in vivo bio-imaging. Osteonecrosis by infectious osteomyelitis and elevation of the inflammatory factors C-reactive protein and IL-6 promoted by P. gingivalis s were also significantly reduced in the presence of silver-coated rods. Overall, our study indicates that silver ion coating of an implant represents a therapeutic option to prevent associated infection, even in anaerobic conditions or against anaerobic bacteria.
Collapse
|
29
|
Wang R, Ni S, Ma L, Li M. Porous construction and surface modification of titanium-based materials for osteogenesis: A review. Front Bioeng Biotechnol 2022; 10:973297. [PMID: 36091459 PMCID: PMC9452912 DOI: 10.3389/fbioe.2022.973297] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Accepted: 07/29/2022] [Indexed: 11/13/2022] Open
Abstract
Titanium and titanium alloy implants are essential for bone tissue regeneration engineering. The current trend is toward the manufacture of implants from materials that mimic the structure, composition and elasticity of bones. Titanium and titanium alloy implants, the most common materials for implants, can be used as a bone conduction material but cannot promote osteogenesis. In clinical practice, there is a high demand for implant surfaces that stimulate bone formation and accelerate bone binding, thus shortening the implantation-to-loading time and enhancing implantation success. To avoid stress shielding, the elastic modulus of porous titanium and titanium alloy implants must match that of bone. Micro-arc oxidation technology has been utilized to increase the surface activity and build a somewhat hard coating on porous titanium and titanium alloy implants. More recently, a growing number of researchers have combined micro-arc oxidation with hydrothermal, ultrasonic, and laser treatments, coatings that inhibit bacterial growth, and acid etching with sand blasting methods to improve bonding to bone. This paper summarizes the reaction at the interface between bone and implant material, the porous design principle of scaffold material, MAO technology and the combination of MAO with other technologies in the field of porous titanium and titanium alloys to encourage their application in the development of medical implants.
Collapse
Affiliation(s)
- Rui Wang
- Department of Stomatology, The Second Hospital of Jilin University, Changchun, China
| | - Shilei Ni
- Department of Plastic and Aesthetic Surgery, Hospital of Stomatology, Jilin University, Changchun, China
| | - Li Ma
- Department of Fever Clinic, The Second Hospital of Jilin University, Changchun, China
| | - Meihua Li
- Department of Stomatology, The Second Hospital of Jilin University, Changchun, China
- *Correspondence: Meihua Li,
| |
Collapse
|
30
|
Ma S, Li X, Hu H, Ma X, Zhao Z, Deng S, Wang J, Zhang L, Wu C, Liu Z, Wang Y. Synergetic osteogenesis of extracellular vesicles and loading RGD colonized on 3D-printed titanium implants. Biomater Sci 2022; 10:4773-4784. [PMID: 35849688 DOI: 10.1039/d2bm00725h] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Titanium (Ti) and its alloys have been universally used as surgical implants, and the clinical need for modifying titanium surfaces to accelerate early stage osseointegration and prevent implant loosening is in huge demand. 3D printing technology is an accurate and controllable method to create titanium implants with complex nanostructures, which provide enough space to react and fit in the microenvironment of cells. Recently, extracellular vesicles (EVs) have attracted attention in promoting osteogenesis. The vesicles derived from bone marrow mesenchymal stem cells (BMSC-EVs) have been proved to pack osteogenic-relative RNAs thereby regulating the osteogenic differentiation and mineralization of the target BMSCs. Arg-Gly-Asp (RGD)-derived peptides are typical peptides used to improve cell attachment and proliferation in bone tissue engineering. A novel strategy is proposed to load RGD-derived peptides on EVs with a fusion peptide (EVsRGD) and colonize EVsRGD on the titanium surface via a specific bonding peptide. In this study, we verify that the presence of EVsRGD enables the realization of the synergetic effect of EVs and RGD, enhancing the osteogenic differentiation and mineralization of BMSCs in vitro, resulting in satisfactory osseointegration around implants in vivo.
Collapse
Affiliation(s)
- Shiqing Ma
- Department of Stomotology, Tianjin Medical University Second Hospital, 23 Pingjiang Road, Hexi District, Tianjin, 300211, China
| | - Xuewen Li
- School and Hospital of Stomatology, Tianjin Medical University, 12 Observatory Road, Tianjin, 030070, China.
| | - Han Hu
- School and Hospital of Stomatology, Tianjin Medical University, 12 Observatory Road, Tianjin, 030070, China.
| | - Xinying Ma
- School and Hospital of Stomatology, Tianjin Medical University, 12 Observatory Road, Tianjin, 030070, China.
| | - Zhezhe Zhao
- School and Hospital of Stomatology, Tianjin Medical University, 12 Observatory Road, Tianjin, 030070, China.
| | - Shu Deng
- Department of Stomotology, Tianjin Medical University Second Hospital, 23 Pingjiang Road, Hexi District, Tianjin, 300211, China
| | - Jie Wang
- School and Hospital of Stomatology, Tianjin Medical University, 12 Observatory Road, Tianjin, 030070, China.
| | - Leyu Zhang
- School and Hospital of Stomatology, Tianjin Medical University, 12 Observatory Road, Tianjin, 030070, China.
| | - Chenxuan Wu
- School and Hospital of Stomatology, Tianjin Medical University, 12 Observatory Road, Tianjin, 030070, China.
| | - Zihao Liu
- School and Hospital of Stomatology, Tianjin Medical University, 12 Observatory Road, Tianjin, 030070, China.
| | - Yonglan Wang
- School and Hospital of Stomatology, Tianjin Medical University, 12 Observatory Road, Tianjin, 030070, China.
| |
Collapse
|
31
|
Ranuša M, Čípek P, Vrbka M, Paloušek D, Křupka I, Hartl M. Tribological behaviour of 3D printed materials for small joint implants: A pilot study. J Mech Behav Biomed Mater 2022; 132:105274. [DOI: 10.1016/j.jmbbm.2022.105274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 05/10/2022] [Accepted: 05/13/2022] [Indexed: 10/18/2022]
|
32
|
Sun X, Yang S, Tong S, Guo S. Study on Exosomes Promoting the Osteogenic Differentiation of ADSCs in Graphene Porous Titanium Alloy Scaffolds. Front Bioeng Biotechnol 2022; 10:905511. [PMID: 35733528 PMCID: PMC9207277 DOI: 10.3389/fbioe.2022.905511] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Accepted: 05/16/2022] [Indexed: 12/02/2022] Open
Abstract
Titanium and titanium alloys (Ti6Al4V and Ti) have been widely used in bone tissue engineering to repair maxillofacial bone defects caused by traumas and tumors. However, such materials are also bio-inert, which does not match the elastic modulus of bone. Therefore, different surface modifications have been proposed for clinical application. Based on the use of traditional titanium alloy in the field of bone repair defects, we prepared a compound Gr-Ti scaffold with ADSC-derived Exos. The results showed that Gr-Ti scaffolds have low toxicity and good biocompatibility, which can promote the adhesion and osteogenic differentiation of ADSCs. Exos played a role in promoting osteogenic differentiation of ADSCs: the mRNA levels of RUNX2, ALP, and Osterix in the Gr-Ti/Exos group were significantly higher than those in the Gr-Ti group, which process related to the Wnt signaling pathway. Gr-Ti scaffolds with ADSCs and ADSC-derived Exos successfully repaired rabbit mandibular defects. The bone mineral density and the bending strength of the Gr-Ti/Exos group was significantly higher than that of the Gr-Ti group. This study provides a theoretical basis for the research and development of new clinical bone repair materials.
Collapse
Affiliation(s)
| | | | | | - Shu Guo
- *Correspondence: Shu Guo, ; Shuang Tong,
| |
Collapse
|
33
|
Guo Z, Zhang R, Que Y, Hu B, Xu S, Hu Y. Case Report: 3D-Printed Prosthesis for Limb Salvage and Joint Preservation After Tibial Sarcoma Resection. Front Surg 2022; 9:873272. [PMID: 35711702 PMCID: PMC9195185 DOI: 10.3389/fsurg.2022.873272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Accepted: 05/09/2022] [Indexed: 11/23/2022] Open
Abstract
Introduction Reconstruction of massive tibial defects in ankle joint-preserving surgery remains challenging though biological and prosthetic methods have been attempted. We surgically treated a patient with only 18-mm distal tibia remaining and reconstructed with a unique three-dimensional printed prosthesis. Case Presentation, Intervention, and Outcomes A 36-year-old male presented to our clinic with complaints of gradually swelling left calf and palpable painless mass for five months. Imageological exam indicated a lesion spanning the entire length of the tibia and surrounding the vascular plexus. Diagnosis of chondrosarcoma was confirmed by biopsy. Amputation was initially recommended but rejected, thus a novel one-step limb-salvage procedure was performed. After en-bloc tumor resection and blood supply rebuilding, a customized, three-dimensional printed prosthesis with porous interface was fixed that connected the tumor knee prosthesis and distal ultra-small bone segment. During a 16-month follow-up, no soft tissue or prosthesis-related complications occurred. The patient was alive with no sign of recurrence or metastasis. Walking ability and full tibiotalar range of motion were preserved. Conclusions Custom-made, three-dimensional printed prosthesis manifested excellent mechanical stability during the follow-up in this joint-preserving surgery. Further investigation of the durability and rate of long-term complications is needed to introduce to routine clinical practice.
Collapse
Affiliation(s)
| | | | | | | | | | - Yong Hu
- Correspondence: Shenglin Xu Yong Hu
| |
Collapse
|
34
|
Abstract
Ti-6Al-4V (Ti64) alloy is one of the most widely used orthopedic implant materials due to its mechanical properties, corrosion resistance, and biocompatibility nature. Porous Ti64 structures are gaining more research interest as bone implants as they can help in reducing the stress-shielding effect when compared to their solid counterpart. The literature shows that porous Ti64 implants fabricated using different additive manufacturing (AM) process routes, such as laser powder bed fusion (L-PBF) and electron beam melting (EBM) can be tailored to mimic the mechanical properties of natural bone. This review paper categorizes porous implant designs into non-gradient (uniform) and gradient (non-uniform) porous structures. Gradient porous design appears to be more promising for orthopedic applications due to its closeness towards natural bone morphology and improved mechanical properties. In addition, this paper outlines the details on bone structure and its properties, mechanical properties, fatigue behavior, multifunctional porous implant designs, current challenges, and literature gaps in the research studies on porous Ti64 bone implants.
Collapse
|
35
|
A Review of Biomimetic Topographies and Their Role in Promoting Bone Formation and Osseointegration: Implications for Clinical Use. Biomimetics (Basel) 2022; 7:biomimetics7020046. [PMID: 35466263 PMCID: PMC9036271 DOI: 10.3390/biomimetics7020046] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 04/13/2022] [Accepted: 04/14/2022] [Indexed: 12/20/2022] Open
Abstract
The use of metallic and polymeric materials for implants has been increasing over the past decade. This trend can be attributed to a variety of factors including a significant increase in basic science research focused on implant material characteristics and how various surface modifications may stimulate osseointegration and, ultimately, fusion. There are many interbody fusion devices and dental implants commercially available; however, detailed information about their surface properties, and the effects that various materials and surface modifications may have on osteogenesis, is lacking in the literature. While the concept of bone-implant osseointegration is a relatively recent addition to the spine fusion literature, there is a comparatively large body of literature related to dental implants. The purpose of this article is to summarize the science of surface modified bone-facing implants, focusing on biomimetic material chemistry and topography of titanium implants, to promote a better understanding of how these characteristics may impact bone formation and osseointegration. This manuscript has the following aspects: highlights the role of titanium and its alloys as potent osteoconductive bioactive materials; explores the importance of biomimetic surface topography at the macro-, micro- and nano-scale; summarizes how material surface design can influence osteogenesis and immune responses in vitro; focuses on the kinds of surface modifications that play a role in the process. Biomimetic surface modifications can be varied across many clinically available biomaterials, and the literature supports the hypothesis that those biomaterial surfaces that exhibit physical properties of bone resorption pits, such as roughness and complex hierarchical structures at the submicron and nanoscale, are more effective in supporting osteoblast differentiation in vitro and osteogenesis in vivo.
Collapse
|
36
|
A Novel 3D Titanium Surface Produced by Selective Laser Sintering to Counteract Streptococcus oralis Biofilm Formation. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app112411915] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The topography of implant surfaces influences the interaction relationship between material and bacteria. The aim of this work was to characterize a novel 3D titanium surface, produced using Selective Laser Sintering (SLS), and to compare the bacterial interaction with machined and double acid etching (DAE) discs. The surface was characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM), and Energy Dispersive X-ray Spectrometry (EDX). The wettability was measured using the sessile method. The microbiological investigation consisted in the cultivation of a bacterial pioneer, Streptococcus oralis, on titanium surfaces, previously covered by human saliva in order to form the acquired pellicle. Then, colony forming units (CFUs), biofilm biomass quantification, analyses of viable and dead cells, and SEM observation were determined after 24 h of S. oralis biofilm formation on the different discs. A significantly higher nano-roughness with respect to the other two groups characterized the novel 3D surface, but the wettability was similar to that of machined samples. The microbiological assays demonstrated that the 3D discs reported significantly lower values of CFUs and biofilm biomass with respect to machined surfaces; however, no significant differences were found with the DAE surfaces. The live/dead staining confirmed the lower percentage of living cells on DAE and 3D surfaces compared with the machined. This novel 3D surface produced by SLS presented a high antiadhesive and antibiofilm activity.
Collapse
|
37
|
Abdelkader H, Fathalla Z, Seyfoddin A, Farahani M, Thrimawithana T, Allahham A, Alani AWG, Al-Kinani AA, Alany RG. Polymeric long-acting drug delivery systems (LADDS) for treatment of chronic diseases: Inserts, patches, wafers, and implants. Adv Drug Deliv Rev 2021; 177:113957. [PMID: 34481032 DOI: 10.1016/j.addr.2021.113957] [Citation(s) in RCA: 53] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 07/13/2021] [Accepted: 08/29/2021] [Indexed: 02/07/2023]
Abstract
Non-oral long-acting drug delivery systems (LADDS) encompass a range of technologies for precisely delivering drug molecules into target tissues either through the systemic circulation or via localized injections for treating chronic diseases like diabetes, cancer, and brain disorders as well as for age-related eye diseases. LADDS have been shown to prolong drug release from 24 h up to 3 years depending on characteristics of the drug and delivery system. LADDS can offer potentially safer, more effective, and patient friendly treatment options compared to more invasive modes of drug administration such as repeated injections or minor surgical intervention. Whilst there is no single technology or definition that can comprehensively embrace LADDS; for the purposes of this review, these systems include solid implants, inserts, transdermal patches, wafers and in situ forming delivery systems. This review covers common chronic illnesses, where candidate drugs have been incorporated into LADDS, examples of marketed long-acting pharmaceuticals, as well as newly emerging technologies, used in the fabrication of LADDS.
Collapse
Affiliation(s)
- Hamdy Abdelkader
- Pharmaceutics Department, Faculty of Pharmacy, Minia University, Minia, Egypt; Department of Pharmaceutics, Faculty of Pharmacy, Deraya University, New Minia City, Minia, Egypt
| | - Zeinab Fathalla
- Pharmaceutics Department, Faculty of Pharmacy, Minia University, Minia, Egypt
| | - Ali Seyfoddin
- Drug Delivery Research Group, Faculty of Health and Environmental Sciences, School of Science, Auckland University of Technology, New Zealand
| | - Mojtaba Farahani
- Department of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
| | - Thilini Thrimawithana
- Discipline of Pharmacy, School of Health and Biomedical Sciences, RMIT University, Melbourne, VIC, Australia
| | - Ayman Allahham
- Discipline of Pharmacy, School of Health and Biomedical Sciences, RMIT University, Melbourne, VIC, Australia
| | - Adam W G Alani
- Department of Pharmaceutical Sciences, College of Pharmacy, Oregon State University, Moody Avenue, RLSB, Portland, OR, United States; Biomedical Engineering Department, Oregon Health & Science University, 2730 S. Moody Avenue, RLSB, Portland, OR, United States; Knight Cancer Institute, Oregon Health & Science University, 2730 S. Moody Avenue, RLSB, Portland, OR, United States
| | - Ali A Al-Kinani
- Drug Discovery, Delivery and Patient Care Theme (DDDPC), Faculty of Science, Engineering and Computing, Kingston University London, Penrhyn Road, Kingston upon Thames, UK.
| | - Raid G Alany
- Drug Discovery, Delivery and Patient Care Theme (DDDPC), Faculty of Science, Engineering and Computing, Kingston University London, Penrhyn Road, Kingston upon Thames, UK; School of Pharmacy, The University of Auckland, Auckland, New Zealand.
| |
Collapse
|
38
|
Jing Z, Ni R, Wang J, Lin X, Fan D, Wei Q, Zhang T, Zheng Y, Cai H, Liu Z. Practical strategy to construct anti-osteosarcoma bone substitutes by loading cisplatin into 3D-printed titanium alloy implants using a thermosensitive hydrogel. Bioact Mater 2021; 6:4542-4557. [PMID: 34027239 PMCID: PMC8138733 DOI: 10.1016/j.bioactmat.2021.05.007] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Revised: 04/12/2021] [Accepted: 05/03/2021] [Indexed: 12/29/2022] Open
Abstract
Surgical resection and perioperative adjuvant chemotherapy-based therapies have improved the prognosis of patients with osteosarcoma; however, intraoperative bone defects, local tumour recurrence, and chemotherapy-induced adverse effects still affect the quality of life of patients. Emerging 3D-printed titanium alloy (Ti6Al4V) implants have advantages over traditional implants in bone repair, including lower elastic modulus, lower stiffness, better bone conduction, more bone in-growth, stronger mechanical interlocking, and lager drug-loading capacity by their inherent porous structure. Here, cisplatin, a clinical first-line anti-osteosarcoma drug, was loaded into Ti6Al4V implants, within a PLGA-PEG-PLGA thermo-sensitive hydrogel, to construct bone substitutes with both anti-osteosarcoma and bone-repair functions. The optimal concentrations of cisplatin (0.8 and 1.6 mg/mL) were first determined in vitro. Thereafter, the anti-tumour effect and biosafety of the cisplatin/hydrogel-loaded implants, as well as their bone-repair potential were evaluated in vivo in tumour-bearing mouse, and bone defect rabbit models, respectively. The loading of cisplatin reduced tumour volume by more than two-thirds (from 641.1 to 201.4 mm3) with negligible organ damage, achieving better anti-tumour effects while avoiding the adverse effects of systemic cisplatin delivery. Although bone repair was hindered by cisplatin loading at 4 weeks, no difference was observed at 8 weeks in the context of implants with versus without cisplatin, indicating acceptable long-term stability of all implants (with 8.48%–10.04% bone in-growth and 16.94%–20.53% osseointegration). Overall, cisplatin/hydrogel-loaded 3D-printed Ti6Al4V implants are safe and effective for treating osteosarcoma-caused bone defects, and should be considered for clinical use. Vehiculated within PLGA-PEG-PLGA hydrogel, cisplatin can be conveniently loaded into 3D-printed Ti6Al4V implants. The cisplatin/hydrogel-loaded implants are safe and show a good anti-tumour potential both in vitro and in vivo. This strategy has better anti-osteosarcoma effects and fewer side effects than the conventional cisplatin delivery method. Cisplatin loading does not decrease the bone repair effect of 3D-printed Ti6Al4V implants 8 weeks after surgery. As the components of the implants are non-toxic, this strategy has great potential for clinical translation.
Collapse
Affiliation(s)
- Zehao Jing
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Renhua Ni
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
| | - Jiedong Wang
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Xinhong Lin
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Daoyang Fan
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Qingguang Wei
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Teng Zhang
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Yufeng Zheng
- Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing, 100871, People's Republic of China
- Corresponding author. Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing, 100871, People's Republic of China.
| | - Hong Cai
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Corresponding author. Department of Orthopedics, Peking University Third Hospital, Beijing 100191, People's Republic of China.
| | - Zhongjun Liu
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
- Corresponding author. Department of Orthopedics, Peking University Third Hospital, Beijing 100191, People's Republic of China.
| |
Collapse
|
39
|
Deng F, Liu L, Li Z, Liu J. 3D printed Ti6Al4V bone scaffolds with different pore structure effects on bone ingrowth. J Biol Eng 2021; 15:4. [PMID: 33478505 PMCID: PMC7818551 DOI: 10.1186/s13036-021-00255-8] [Citation(s) in RCA: 48] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Accepted: 01/03/2021] [Indexed: 12/14/2022] Open
Abstract
The microstructure of porous scaffolds plays a vital role in bone regeneration, but its optimal shape is still unclear. In this study, four kinds of porous titanium alloy scaffolds with similar porosities (65%) and pore sizes (650 μm) and different structures were prepared by selective laser melting. Four scaffolds were implanted into the distal femur of rabbits to evaluate bone tissue growth in vivo. Micro-CT and hard tissue section analyses were performed 6 and 12 weeks after the operation to reveal the bone growth of the porous scaffold. The results show that diamond lattice unit (DIA) bone growth is the best of the four topological scaffolds. Through computational fluid dynamics (CFD) analysis, the permeability, velocity and flow trajectory inside the scaffold structure were calculated. The internal fluid velocity difference of the DIA structure is the smallest, and the trajectory of fluid flow inside the scaffold is the longest, which is beneficial for blood vessel growth, nutrient transport and bone formation. In this study, the mechanism of bone growth in different structures was revealed by in vivo experiments combined with CFD, providing a new theoretical basis for the design of bone scaffolds in the future.
Collapse
Affiliation(s)
- Fuyuan Deng
- Department of Orthopaedics, The Affiliated Hospital of Southwest Medical University, Luzhou, 646000, Sichuan, China.,Sichuan Provincial Laboratory of Orthopaedic Engineering, Luzhou, 646000, Sichuan, China
| | - Linlin Liu
- School of Mechanical Engineering, Sichuan University, Chengdu, 610065, Sichuan, China
| | - Zhong Li
- Department of Orthopaedics, The Affiliated Hospital of Southwest Medical University, Luzhou, 646000, Sichuan, China. .,Sichuan Provincial Laboratory of Orthopaedic Engineering, Luzhou, 646000, Sichuan, China.
| | - Juncai Liu
- Department of Orthopaedics, The Affiliated Hospital of Southwest Medical University, Luzhou, 646000, Sichuan, China. .,Sichuan Provincial Laboratory of Orthopaedic Engineering, Luzhou, 646000, Sichuan, China.
| |
Collapse
|
40
|
Tao F, Ma S, Tao H, Jin L, Luo Y, Zheng J, Xiang W, Deng H. Chitosan-based drug delivery systems: From synthesis strategy to osteomyelitis treatment - A review. Carbohydr Polym 2020; 251:117063. [PMID: 33142615 DOI: 10.1016/j.carbpol.2020.117063] [Citation(s) in RCA: 67] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 08/22/2020] [Accepted: 09/03/2020] [Indexed: 12/21/2022]
Abstract
Osteomyelitis is a complex disease in orthopedics mainly caused by bacterial pathogens invading bone or bone marrow. The treatment of osteomyelitis is highly difficult and it is a major challenge in orthopedic surgery. The long-term systemic use of antibiotics may lead to antibiotic resistance and has limited effects on eradicating local biofilms. Localized antibiotic delivery after surgical debridement can overcome the problem of antibiotic resistance and reduce systemic toxicity. Chitosan, a special cationic polysaccharide, is a product extracted from the deacetylation of chitin. It has numerous advantages, such as nontoxicity, biocompatibility, and biodegradability. Recently, chitosan has attracted significant attention in bacterial inhibition and drug delivery. Because chitosan contains many functional bioactive groups conducive to chemical reaction and modification, some chitosan-based biomaterials have been applied as the local antibiotic delivery systems in the treatment of osteomyelitis. This review aims to introduce recent advances in the biomedical applications of chitosan-based drug delivery systems in osteomyelitis treatment and to highlight the perspectives for further studies.
Collapse
Affiliation(s)
- Fenghua Tao
- Department of Orthopedics, Renmin Hospital of Wuhan University, Wuhan University, Wuhan 430060, China; Hubei International Scientific and Technological Cooperation Base of Sustainable Resource and Energy, Hubei Key Laboratory of Biomass Resource Chemistry and Environmental Biotechnology, School of Resource and Environmental Science, Wuhan University, Wuhan 430079, China
| | - Sijia Ma
- Department of Orthopedics, Renmin Hospital of Wuhan University, Wuhan University, Wuhan 430060, China
| | - Hai Tao
- Department of Orthopedics, Renmin Hospital of Wuhan University, Wuhan University, Wuhan 430060, China
| | - Lin Jin
- Department of Orthopedics, Renmin Hospital of Wuhan University, Wuhan University, Wuhan 430060, China
| | - Yue Luo
- Department of Orthopedics, Renmin Hospital of Wuhan University, Wuhan University, Wuhan 430060, China
| | - Jian Zheng
- Department of Orthopedics, Renmin Hospital of Wuhan University, Wuhan University, Wuhan 430060, China
| | - Wei Xiang
- Department of Orthopedics, Renmin Hospital of Wuhan University, Wuhan University, Wuhan 430060, China; Hubei International Scientific and Technological Cooperation Base of Sustainable Resource and Energy, Hubei Key Laboratory of Biomass Resource Chemistry and Environmental Biotechnology, School of Resource and Environmental Science, Wuhan University, Wuhan 430079, China.
| | - Hongbing Deng
- Hubei International Scientific and Technological Cooperation Base of Sustainable Resource and Energy, Hubei Key Laboratory of Biomass Resource Chemistry and Environmental Biotechnology, School of Resource and Environmental Science, Wuhan University, Wuhan 430079, China.
| |
Collapse
|