Eichenlaub M, Pleus S, Rothenbühler M, Bailey TS, Bally L, Brazg R, Bruttomesso D, Diem P, Eriksson Boija E, Fokkert M, Haug C, Hinzmann R, Jendle J, Klonoff DC, Mader JK, Makris K, Moser O, Nichols JH, Nørgaard K, Pemberton J, Selvin E, Spanou L, Thomas A, Tran NK, Witthauer L, Slingerland RJ, Freckmann G. Comparator Data Characteristics and Testing Procedures for the Clinical Performance Evaluation of Continuous Glucose Monitoring Systems. Diabetes Technol Ther 2024; 26:263-275. [PMID: 38194227 PMCID: PMC10979680 DOI: 10.1089/dia.2023.0465] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2024]
Abstract
Comparing the performance of different continuous glucose monitoring (CGM) systems is challenging due to the lack of comprehensive guidelines for clinical study design. In particular, the absence of concise requirements for the distribution of comparator (reference) blood glucose (BG) concentrations and their rate of change (RoC) that are used to evaluate CGM performance, impairs comparability. For this article, several experts in the field of CGM performance testing have collaborated to propose characteristics of the distribution of comparator measurements that should be collected during CGM performance testing. Specifically, it is proposed that at least 7.5% of comparator BG concentrations are <70 mg/dL (3.9 mmol/L) and >300 mg/dL (16.7 mmol/L), respectively, and that at least 7.5% of BG-RoC combinations indicate fast BG changes with impending hypo- or hyperglycemia, respectively. These proposed characteristics of the comparator data can facilitate the harmonization of testing conditions across different studies and CGM systems and ensure that the most relevant scenarios representing real-life situations are established during performance testing. In addition, a study protocol and testing procedure for the manipulation of glucose levels are suggested that enable the collection of comparator data with these characteristics. This work is an important step toward establishing a future standard for the performance evaluation of CGM systems.
Collapse
Affiliation(s)
- Manuel Eichenlaub
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Stefan Pleus
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
| | | | | | - Lia Bally
- Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism, Inselspital Bern, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Ronald Brazg
- Rainier Clinical Research Center, Renton, Washington, USA
| | - Daniela Bruttomesso
- Division of Metabolic Disease, Department of Medicine, University of Padua, Padua, Italy
| | - Peter Diem
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
- Endokrinologie Diabetologie Bern, Bern, Switzerland
| | - Elisabet Eriksson Boija
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
- Equalis AB, Uppsala, Sweden
| | - Marion Fokkert
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
- Department of Clinical Chemistry, Isala Clinics, Zwolle, The Netherlands
| | - Cornelia Haug
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Rolf Hinzmann
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
- Roche Diabetes Care GmbH, Mannheim, Germany
| | - Johan Jendle
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
- School of Medical Sciences, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
| | - David C. Klonoff
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
- Diabetes Research Institute of Mills-Peninsula Medical Center, San Mateo, California, USA
| | - Julia K. Mader
- Division of Endocrinology and Diabetology, Medical University of Graz, Graz, Austria
| | - Konstantinos Makris
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
- Clinical Biochemistry Department, KAT General Hospital, Athens, Greece
| | - Othmar Moser
- Division of Endocrinology and Diabetology, Medical University of Graz, Graz, Austria
- Department of Exercise Physiology and Metabolism, University of Bayreuth, Bayreuth, Germany
| | - James H. Nichols
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
- Department of Pathology, Microbiology and Immunology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Kirsten Nørgaard
- Steno Diabetes Center Copenhagen, Herlev, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - John Pemberton
- Birmingham Women's and Children's Foundation Trust, Birmingham, United Kingdom
| | - Elizabeth Selvin
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
- Department of Cardiovascular and Clinical Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| | - Loukia Spanou
- Department of Endocrinology, Diabetes and Metabolism, Hellenic Red Cross Hospital, Athens, Greece
| | - Andreas Thomas
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
- Independent Scientific Consulting, Pirna, Germany
| | - Nam K. Tran
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
- Department of Pathology and Laboratory Medicine, University of California Davis Health, Sacramento, California, USA
| | - Lilian Witthauer
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
- Diabetes Center Berne, Bern, Switzerland
- Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism, Inselspital Bern, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Robbert J. Slingerland
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
- Department of Clinical Chemistry, Isala Clinics, Zwolle, The Netherlands
| | - Guido Freckmann
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
- IFCC Scientific Division, Working Group on Continuous Glucose Monitoring
| |
Collapse
|
2
|
Olsen MT, Klarskov CK, Dungu AM, Hansen KB, Pedersen-Bjergaard U, Kristensen PL. Statistical Packages and Algorithms for the Analysis of Continuous Glucose Monitoring Data: A Systematic Review. J Diabetes Sci Technol 2024:19322968231221803. [PMID: 38179940 DOI: 10.1177/19322968231221803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/06/2024]
Abstract
BACKGROUND Continuous glucose monitoring (CGM) measures glucose levels every 1 to 15 minutes and is widely used in clinical and research contexts. Statistical packages and algorithms reduce the time-consuming and error-prone process of manually calculating CGM metrics and contribute to standardizing CGM metrics defined by international consensus. The aim of this systematic review is to summarize existing data on (1) statistical packages for retrospective CGM data analysis and (2) statistical algorithms for retrospective CGM analysis not available in these statistical packages. METHODS A systematic literature search in PubMed and EMBASE was conducted on September 19, 2023. We also searched Google Scholar and Google Search until October 12, 2023 as sources of gray literature and performed reference checks of the included literature. Articles in English and Danish were included. This systematic review is registered with PROSPERO (CRD42022378163). RESULTS A total of 8731 references were screened and 46 references were included. We identified 23 statistical packages for the analysis of CGM data. The statistical packages could calculate many metrics of the 2022 CGM consensus and non-consensus CGM metrics, and 22/23 (96%) statistical packages were freely available. Also, 23 statistical algorithms were identified. The statistical algorithms could be divided into three groups based on content: (1) CGM data reduction (eg, clustering of CGM data), (2) composite CGM outcomes, and (3) other CGM metrics. CONCLUSION This systematic review provides detailed tabular and textual up-to-date descriptions of the contents of statistical packages and statistical algorithms for retrospective analysis of CGM data.
Collapse
Affiliation(s)
- Mikkel Thor Olsen
- Department of Endocrinology and Nephrology, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark
| | - Carina Kirstine Klarskov
- Department of Endocrinology and Nephrology, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark
| | - Arnold Matovu Dungu
- Department of Pulmonary and Infectious Diseases, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark
| | - Katrine Bagge Hansen
- Steno Diabetes Center Copenhagen, Copenhagen University Hospital-Herlev-Gentofte, Herlev, Denmark
| | - Ulrik Pedersen-Bjergaard
- Department of Endocrinology and Nephrology, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark
- Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Peter Lommer Kristensen
- Department of Endocrinology and Nephrology, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark
- Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
3
|
Pellizzari E, Prendin F, Cappon G, Sparacino G, Facchinetti A. drCORRECT: An Algorithm for the Preventive Administration of Postprandial Corrective Insulin Boluses in Type 1 Diabetes Management. J Diabetes Sci Technol 2023:19322968231221768. [PMID: 38158565 DOI: 10.1177/19322968231221768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
BACKGROUND In type 1 diabetes therapy, precise tuning of postprandial corrective insulin boluses (CIBs) is crucial to mitigate hyperglycemia without inducing dangerous hypoglycemic events. Several heuristic formulas accounting for continuous glucose monitoring (CGM) trend have been proposed in the literature. However, these formulas suggest a lot of quantized CIB adjustments, and they lack personalization. METHOD drCORRECT algorithm proposed in this work employs a patient-specific time parameter and the "dynamic risk" (DR) measure to determine postprandial CIB suggestion. The expected benefits include the reduction of time in hyperglycemia, thanks to the preventive action exploited through DR. drCORRECT has been assessed retrospectively vs the literature methods proposed by Aleppo et al (AL), Bruttomesso et al (BR), and Ziegler et al (ZI) using a data set of 49 CGM daily traces recorded in free-living conditions. Retrospective evaluation of the algorithms is made possible by the use of ReplayBG, a digital twin-based tool that allows assessing alternative insulin therapies on already collected glucose data. Efficacy in terms of glucose control was measured by temporal, risk indicators, and dedicated hyperglycemic/hypoglycemic events metrics. RESULTS drCORRECT significantly reduces time spent in hyperglycemia when compared with AL and BR (33.52 [24.16, 39.89]% vs 39.76 [22.54, 48.15]% and 36.32 [26.91, 45.93]%, respectively); significantly reduces daily injected insulin (5.97 [3.80, 8.06] U vs 7.5 [5.21, 10.34] U), glycemia risk index (38.78 [26.58, 55.39] vs 40.78 [27.95, 70.30]), and time spent in hypoglycemia (0.00 [0.00, 1.74]% vs 0.00 [0.00, 10.23]%) when compared with ZI, resulting overall in a safer strategy. CONCLUSIONS The proposed drCORRECT algorithm allows preventive actions thanks to the personalized timing configuration and the introduction of the innovative DR-based CIB threshold, proving to be a valid alternative to the available heuristic literature methods.
Collapse
Affiliation(s)
- Elisa Pellizzari
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Francesco Prendin
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Giacomo Cappon
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Giovanni Sparacino
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Andrea Facchinetti
- Department of Information Engineering, University of Padova, Padova, Italy
| |
Collapse
|
4
|
Cappon G, Sparacino G, Facchinetti A. AGATA: A Toolbox for Automated Glucose Data Analysis. J Diabetes Sci Technol 2023:19322968221147570. [PMID: 36602030 DOI: 10.1177/19322968221147570] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
BACKGROUND Analyzing continuous glucose monitoring (CGM) data is a mandatory step for multiple purposes spanning from reporting clinical trial outcomes to developing new algorithms for diabetes management. This task is repetitive, and scientists struggle in computing literature glucose control metrics and waste time in reproducing possibly complex plots and reports. For this reason, to provide the diabetes technology community a unified tool, here we present Automated Glucose dATa Analysis (AGATA), an automated glucose data analysis toolbox developed in MATLAB/Octave. METHODS Automated Glucose dATa Analysis is an open-source software program to visualize and preprocess CGM data, compute glucose control metrics, detect adverse events, evaluate the effectiveness of users' prediction algorithms, and compare study arms. Automated Glucose dATa Analysis can be used as a standalone computer application accessible through a dedicated graphical user interface, particularly suitable for clinicians, or by integrating its functionalities in user-defined MATLAB/Octave scripts, which fits the need of researchers and developers. To demonstrate its features, we used AGATA to analyze CGM data of two subjects extracted from a publicly available data set of individuals with type one diabetes. Finally, AGATA's features are compared against those of 12 noncommercial software programs for CGM data analysis. RESULTS Using AGATA, we easily preprocessed, analyzed, and visualized CGM data in a handy way, in compliance with the requirements and the standards defined in the literature. Compared to the other considered software programs, AGATA offers more functionalities and capabilities. CONCLUSION Automated Glucose dATa Analysis is easy to use and reduces the burden of CGM data analysis. It is freely available in GitHub at https://github.com/gcappon/agata.
Collapse
Affiliation(s)
- Giacomo Cappon
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Giovanni Sparacino
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Andrea Facchinetti
- Department of Information Engineering, University of Padova, Padova, Italy
| |
Collapse
|
5
|
Cappon G, Noaro G, Camerlingo N, Cossu L, Sparacino G, Facchinetti A. A New Decision Support System for Type 1 Diabetes Management. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:1993-1996. [PMID: 34891678 DOI: 10.1109/embc46164.2021.9629797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Type 1 diabetes (T1D) is a chronic life-threatening metabolic condition which needs to be accurately and continuously managed with care by multiple daily exogenous insulin injections, frequent blood glucose concentration monitoring, ad-hoc diet, and physical activity. In the last decades, new technologies, such as continuous glucose monitoring sensors, eased the burden for T1D patients and opened new therapy perspectives by fostering the development of decision support systems (DSS). A DSS for T1D should be able to provide patients with advice aimed at improving metabolic control and reducing the number of actions related to therapy handling. Major challenges are the vast intra-/inter-subject physiological variability and the many factors that impact glucose metabolism. The present work illustrates a new DSS for T1D management. The algorithmic core includes a module for optimal, personalized, insulin dose calculation and a module that triggers the assumption of rescue carbohydrates to avoid/mitigate impending hypoglycemic events. The algorithms are integrated within a prototype communication platform that comprises a mobile app, a real-time telemonitoring interface, and a cloud server to safely store patients' data. Tests made in silico show that the use of the new algorithms lead to metabolic control indices significantly better than those obtained by the standard care for T1D. The preliminary test of the prototype platform suggests that it is robust, performant, and well-accepted by both patients and clinicians. Future work will focus on the refinement of the communication platform and the design of a clinical trial to assess the system effectiveness in real-life conditions.Clinical Relevance- The presented DSS is a promising tool to facilitate T1D daily management and improve therapy efficacy.
Collapse
|
6
|
Marcus Y, Eldor R, Yaron M, Shaklai S, Ish-Shalom M, Shefer G, Stern N, Golan N, Dvir AZ, Pele O, Gonen M. Improving blood glucose level predictability using machine learning. Diabetes Metab Res Rev 2020; 36:e3348. [PMID: 32445286 DOI: 10.1002/dmrr.3348] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Revised: 05/12/2020] [Accepted: 05/18/2020] [Indexed: 01/17/2023]
Abstract
This study was designed to improve blood glucose level predictability and future hypoglycemic and hyperglycemic event alerts through a novel patient-specific supervised-machine-learning (SML) analysis of glucose level based on a continuous-glucose-monitoring system (CGM) that needs no human intervention, and minimises false-positive alerts. The CGM data over 7 to 50 non-consecutive days from 11 type-1 diabetic patients aged 18 to 39 with a mean HbA1C of 7.5% ± 1.2% were analysed using four SML models. The algorithm was constructed to choose the best-fit model for each patient. Several statistical parameters were calculated to aggregate the magnitudes of the prediction errors. The personalised solutions provided by the algorithm were effective in predicting glucose levels 30 minutes after the last measurement. The average root-mean-square-error was 20.48 mg/dL and the average absolute-mean-error was 15.36 mg/dL when the best-fit model was selected for each patient. Using the best-fit-model, the true-positive-hypoglycemia-prediction-rate was 64%, whereas the false-positive- rate was 4.0%, and the false-negative-rate was 0.015%. Similar results were found even when only CGM samples below 70 were considered. The true-positive-hyperglycemia-prediction-rate was 61%. State-of-the-art SML tools are effective in predicting the glucose level values of patients with type-1diabetes and notifying these patients of future hypoglycemic and hyperglycemic events, thus improving glycemic control. The algorithm can be used to improve the calculation of the basal insulin rate and bolus insulin, and suitable for a closed loop "artificial pancreas" system. The algorithm provides a personalised medical solution that can successfully identify the best-fit method for each patient.
Collapse
Affiliation(s)
- Yonit Marcus
- The Institute of Endocrinology, Metabolism and Hypertension, Tel-Aviv Sourasky Medical Centre, Tel Aviv, Israel
- The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Roy Eldor
- The Institute of Endocrinology, Metabolism and Hypertension, Tel-Aviv Sourasky Medical Centre, Tel Aviv, Israel
- The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Mariana Yaron
- The Institute of Endocrinology, Metabolism and Hypertension, Tel-Aviv Sourasky Medical Centre, Tel Aviv, Israel
- The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Sigal Shaklai
- The Institute of Endocrinology, Metabolism and Hypertension, Tel-Aviv Sourasky Medical Centre, Tel Aviv, Israel
- The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Maya Ish-Shalom
- The Institute of Endocrinology, Metabolism and Hypertension, Tel-Aviv Sourasky Medical Centre, Tel Aviv, Israel
- The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Gabi Shefer
- The Institute of Endocrinology, Metabolism and Hypertension, Tel-Aviv Sourasky Medical Centre, Tel Aviv, Israel
- The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Naftali Stern
- The Institute of Endocrinology, Metabolism and Hypertension, Tel-Aviv Sourasky Medical Centre, Tel Aviv, Israel
- The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Nehor Golan
- The Department of Computer Science, Ariel University, Ariel, Israel
- Ariel Cyber Innovation Centre, Ariel University, Ariel, Israel
| | - Amit Z Dvir
- The Department of Computer Science, Ariel University, Ariel, Israel
- Ariel Cyber Innovation Centre, Ariel University, Ariel, Israel
| | - Ofir Pele
- The Department of Computer Science, Ariel University, Ariel, Israel
| | - Mira Gonen
- The Department of Computer Science, Ariel University, Ariel, Israel
| |
Collapse
|
7
|
Camerlingo N, Vettoretti M, Del Favero S, Cappon G, Sparacino G, Facchinetti A. In-silico Assessment of Preventive Hypotreatment Efficacy and Development of a Continuous Glucose Monitoring Based Algorithm to Prevent/Mitigate Hypoglycemia in Type 1 Diabetes. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:4133-4136. [PMID: 31946780 DOI: 10.1109/embc.2019.8857268] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In Type 1 diabetes (T1D) standard treatment, the mitigation of hypoglycemia is achieved by the assumption of small amounts of carbohydrates (CHO), called hypotreatments (HTs), as soon as hypoglycemia is revealed. However, since CHO takes time to reach the blood stream, hypoglycemia cannot be totally avoided. Our purpose is to evaluate in-silico the effectiveness of preventive HTs and to propose a new real-time algorithm for the mitigation/avoidance of hypoglycemia, based on continuous glucose monitoring (CGM) sensor data. To such a purpose, the algorithm exploits the "dynamic risk" non linear-function that, by combining CGM value and trend, allows predicting the forthcoming hypoglycemic event. The algorithm is tested in an ideal noise-free environment on 100 virtual subjects (VSs) generated by the UVA/Padova T1D simulator and undergoing a single-meal experiment, with induced post-meal hypoglycemia. Compared to a reference HT rule, which suggest to assume HTs when hypoglycemia is detected, the algorithm reduces, on median [25th - 75th percentiles], both the time spent in hypoglycemia (from 36 [29 - 43] min to 10 [0 - 20] min) and the post-treatment rebound (from 136 [121 - 148] mg/dl to 114 [98 - 130] mg/dl). In conclusion, the proposed real-time algorithm efficiently generates preventive HTs that allow to almost totally avoid hypoglycemia. Future work will concern to modify the algorithm for detecting in advance the severity of the hypoglycemic episode -since performance are influenced on the hypoglycemic episode aggressiveness level- and to assess algorithm in a more challenging environment, including CGM measurement error.
Collapse
|
8
|
Camerlingo N, Vettoretti M, Del Favero S, Cappon G, Sparacino G, Facchinetti A. A Real-Time Continuous Glucose Monitoring-Based Algorithm to Trigger Hypotreatments to Prevent/Mitigate Hypoglycemic Events. Diabetes Technol Ther 2019; 21:644-655. [PMID: 31335191 DOI: 10.1089/dia.2019.0139] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Background: The standard treatment for hypoglycemia recommended by the American Diabetes Association (ADA) suggests patients with diabetes to take small amounts of carbohydrates, the so-called hypotreatments (HTs), as soon as blood glucose concentration goes below 70 mg/dL. However, prevention, or at least mitigation, of hypoglycemic events could be achieved by triggering HTs ahead of time thanks to the use of the predictive capabilities of suitable real-time algorithms fed by continuous glucose monitoring (CGM) sensor data. Materials and Methods: The algorithm proposed in this article to trigger HTs for preventing forthcoming hypoglycemic events is based on the computation of the "dynamic risk", there is a nonlinear function combining current glycemia with its rate-of-change, both provided by CGM. A comparison of performance of the proposed algorithm against the ADA guidelines is made, in silico, on datasets of 100 virtual patients undergoing a single-meal experiment, with induced postmeal hypoglycemia, generated by the UVA/Padova type 1 diabetes simulator. Results: On noise-free CGM data, the proposed algorithm reduces the time spent in hypoglycemia, on median [25th-75th percentiles] from 36 [29-43] to 0 [0-11] min (P < 0.0001), with a concomitant decrease of the post-treatment rebound (PTR) in glucose concentration, on median [25th-75th percentiles] from 136 [121-148] to 121 [116-127] mg/dL (P < 0.0001). On noisy CGM data, there is still a reduction of both time spent in hypoglycemia from 41 [28-49] min to 25 [0-41] min (P < 0.0001) and PTR from 174 [146-189] mg/dL to 137 [123-151] mg/dL (P < 0.0001). Conclusions: The potentiality of the new algorithm in generating preventive HTs, which can allow significant reduction of hypoglycemia without concomitant increase of hyperglycemia, suggests its further development and test in silico, for example, simulating both insulin pump and multiple-daily-injection therapies.
Collapse
Affiliation(s)
- Nunzio Camerlingo
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Martina Vettoretti
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Simone Del Favero
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Giacomo Cappon
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Giovanni Sparacino
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Andrea Facchinetti
- Department of Information Engineering, University of Padova, Padova, Italy
| |
Collapse
|
9
|
Cappon G, Facchinetti A, Sparacino G, Georgiou P, Herrero P. Classification of Postprandial Glycemic Status with Application to Insulin Dosing in Type 1 Diabetes-An In Silico Proof-of-Concept. SENSORS 2019; 19:s19143168. [PMID: 31323886 PMCID: PMC6679291 DOI: 10.3390/s19143168] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 07/15/2019] [Accepted: 07/16/2019] [Indexed: 02/06/2023]
Abstract
In the daily management of type 1 diabetes (T1D), determining the correct insulin dose to be injected at meal-time is fundamental to achieve optimal glycemic control. Wearable sensors, such as continuous glucose monitoring (CGM) devices, are instrumental to achieve this purpose. In this paper, we show how CGM data, together with commonly recorded inputs (carbohydrate intake and bolus insulin), can be used to develop an algorithm that allows classifying, at meal-time, the post-prandial glycemic status (i.e., blood glucose concentration being too low, too high, or within target range). Such an outcome can then be used to improve the efficacy of insulin therapy by reducing or increasing the corresponding meal bolus dose. A state-of-the-art T1D simulation environment, including intraday variability and a behavioral model, was used to generate a rich in silico dataset corresponding to 100 subjects over a two-month scenario. Then, an extreme gradient-boosted tree (XGB) algorithm was employed to classify the post-prandial glycemic status. Finally, we demonstrate how the XGB algorithm outcome can be exploited to improve glycemic control in T1D through real-time adjustment of the meal insulin bolus. The proposed XGB algorithm obtained good accuracy at classifying post-prandial glycemic status (AUROC = 0.84 [0.78, 0.87]). Consequently, when used to adjust, in real-time, meal insulin boluses obtained with a bolus calculator, the proposed approach improves glycemic control when compared to the baseline bolus calculator. In particular, percentage time in target [70, 180] mg/dL was improved from 61.98 (±13.89) to 67.00 (±11.54; p < 0.01) without increasing hypoglycemia.
Collapse
Affiliation(s)
- Giacomo Cappon
- Department of Information Engineering, University of Padova, 35131 Padova (PD), Italy
| | - Andrea Facchinetti
- Department of Information Engineering, University of Padova, 35131 Padova (PD), Italy
| | - Giovanni Sparacino
- Department of Information Engineering, University of Padova, 35131 Padova (PD), Italy
| | - Pantelis Georgiou
- Department of Electrical and Electronical Engineering, Imperial College London, London W5 5SA, UK
| | - Pau Herrero
- Department of Electrical and Electronical Engineering, Imperial College London, London W5 5SA, UK.
| |
Collapse
|
10
|
Zanon M, Mueller M, Zakharov P, Talary MS, Donath M, Stahel WA, Caduff A. First Experiences With a Wearable Multisensor Device in a Noninvasive Continuous Glucose Monitoring Study at Home, Part II: The Investigators' View. J Diabetes Sci Technol 2018; 12:554-561. [PMID: 29145749 PMCID: PMC6154230 DOI: 10.1177/1932296817740591] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
BACKGROUND Extensive past work showed that noninvasive continuous glucose monitoring with a wearable multisensor device worn on the upper arm provides useful information about glucose trends to improve diabetes therapy in controlled and semicontrolled conditions. METHOD To test previous findings also in uncontrolled conditions, a long term at home study has been organized to collect multisensor and reference glucose data in a population of 20 type 1 diabetes subjects. A total of 1072 study days were collected and a fully on-line compatible algorithmic routine linking multisensor data to glucose applied to estimate glucose levels noninvasively. RESULTS The algorithm used here calculates glucose values from sensor data and adds a constant obtained by a daily calibration. It provides point inaccuracy measured by a MARD of 35.4 mg/dL on test data. This is higher than current state-of-the-art minimally invasive devices, but still 86.9% of glucose rate points fall within the zone AR+BR. CONCLUSIONS The multisensor device and the algorithmic routine used earlier in controlled conditions tracks glucose changes also in uncontrolled conditions, although with lower accuracy. The examination of learning curves suggests that obtaining more data would not improve the results. Therefore, further efforts would focus on the development of more complex algorithmic routines able to compensate for environmental and physiological confounders better.
Collapse
Affiliation(s)
| | | | | | | | - Marc Donath
- Clinic for Endocrinology and Diabetes,
University Hospital Basel, Basel, Switzerland
| | | | | |
Collapse
|
11
|
Fabris C, Facchinetti A, Fico G, Sambo F, Arredondo MT, Cobelli C. Parsimonious Description of Glucose Variability in Type 2 Diabetes by Sparse Principal Component Analysis. J Diabetes Sci Technol 2015; 10:119-24. [PMID: 26232371 PMCID: PMC4738208 DOI: 10.1177/1932296815596173] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Abnormal glucose variability (GV) is a risk factor for diabetes complications, and tens of indices for its quantification from continuous glucose monitoring (CGM) time series have been proposed. However, the information carried by these indices is redundant, and a parsimonious description of GV can be obtained through sparse principal component analysis (SPCA). We have recently shown that a set of 10 metrics selected by SPCA is able to describe more than 60% of the variance of 25 GV indicators in type 1 diabetes (T1D). Here, we want to extend the application of SPCA to type 2 diabetes (T2D). METHODS A data set of CGM time series collected in 13 T2D subjects was considered. The 25 GV indices considered for T1D were evaluated. SPCA was used to select a subset of indices able to describe the majority of the original variance. RESULTS A subset of 10 indicators was selected and allowed to describe 83% of the variance of the original pool of 25 indices. Four metrics sufficient to describe 67% of the original variance turned out to be shared by the parsimonious sets of indices in T1D and T2D. CONCLUSIONS Starting from a pool of 25 indices assessed from CGM time series in T2D subjects, reduced subsets of metrics virtually providing the same information content can be determined by SPCA. The fact that these indices also appear in the parsimonious description of GV in T1D may indicate that they could be particularly informative of GV in diabetes, regardless of the specific type of disease.
Collapse
Affiliation(s)
- Chiara Fabris
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Andrea Facchinetti
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Giuseppe Fico
- Life Supporting Technologies Group, Dpt. TBF - Photonic Technology and Bioengineering, Technical University of Madrid, Madrid, Spain
| | - Francesco Sambo
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Maria Teresa Arredondo
- Life Supporting Technologies Group, Dpt. TBF - Photonic Technology and Bioengineering, Technical University of Madrid, Madrid, Spain
| | - Claudio Cobelli
- Department of Information Engineering, University of Padova, Padova, Italy
| |
Collapse
|
12
|
Caduff A, Zanon M, Mueller M, Zakharov P, Feldman Y, De Feo O, Donath M, Stahel WA, Talary MS. The Effect of a Global, Subject, and Device-Specific Model on a Noninvasive Glucose Monitoring Multisensor System. J Diabetes Sci Technol 2015; 9:865-72. [PMID: 25910542 PMCID: PMC4525657 DOI: 10.1177/1932296815579459] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND We study here the influence of different patients and the influence of different devices with the same patients on the signals and modeling of data from measurements from a noninvasive Multisensor glucose monitoring system in patients with type 1 diabetes. The Multisensor includes several sensors for biophysical monitoring of skin and underlying tissue integrated on a single substrate. METHOD Two Multisensors were worn simultaneously, 1 on the upper left and 1 on the upper right arm by 4 patients during 16 study visits. Glucose was administered orally to induce 2 consecutive hyperglycemic excursions. For the analysis, global (valid for a population of patients), personal (tailored to a specific patient), and device-specific multiple linear regression models were derived. RESULTS We find that adjustments of the model to the patients improves the performance of the glucose estimation with an MARD of 17.8% for personalized model versus a MARD of 21.1% for the global model. At the same time the effect of the measurement side is negligible. The device can equally well measure on the left or right arm. We also see that devices are equal in the linear modeling. Thus hardware calibration of the sensors is seen to be sufficient to eliminate interdevice differences in the measured signals. CONCLUSIONS We demonstrate that the hardware of the 2 devices worn on the left and right arms are consistent yielding similar measured signals and thus glucose estimation results with a global model. The 2 devices also return similar values of glucose errors. These errors are mainly due to nonstationarities in the measured signals that are not solved by the linear model, thus suggesting for more sophisticated modeling approaches.
Collapse
Affiliation(s)
| | | | | | | | - Yuri Feldman
- Department of Applied Physics, Hebrew University of Jerusalem, Jerusalem, Israel
| | | | - Marc Donath
- Clinic for Endocrinology and Diabetes, University Hospital Basel, Basel, Switzerland
| | | | | |
Collapse
|
13
|
Facchinetti A, Del Favero S, Sparacino G, Cobelli C. Model of glucose sensor error components: identification and assessment for new Dexcom G4 generation devices. Med Biol Eng Comput 2014; 53:1259-69. [PMID: 25416850 DOI: 10.1007/s11517-014-1226-y] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Accepted: 11/07/2014] [Indexed: 11/28/2022]
Abstract
It is clinically well-established that minimally invasive subcutaneous continuous glucose monitoring (CGM) sensors can significantly improve diabetes treatment. However, CGM readings are still not as reliable as those provided by standard fingerprick blood glucose (BG) meters. In addition to unavoidable random measurement noise, other components of sensor error are distortions due to the blood-to-interstitial glucose kinetics and systematic under-/overestimations associated with the sensor calibration process. A quantitative assessment of these components, and the ability to simulate them with precision, is of paramount importance in the design of CGM-based applications, e.g., the artificial pancreas (AP), and in their in silico testing. In the present paper, we identify and assess a model of sensor error of for two sensors, i.e., the G4 Platinum (G4P) and the advanced G4 for artificial pancreas studies (G4AP), both belonging to the recently presented "fourth" generation of Dexcom CGM sensors but different in their data processing. Results are also compared with those obtained by a sensor belonging to the previous, "third," generation by the same manufacturer, the SEVEN Plus (7P). For each sensor, the error model is derived from 12-h CGM recordings of two sensors used simultaneously and BG samples collected in parallel every 15 ± 5 min. Thanks to technological innovations, G4P outperforms 7P, with average mean absolute relative difference (MARD) of 11.1 versus 14.2%, respectively, and lowering of about 30% the error of each component. Thanks to the more sophisticated data processing algorithms, G4AP resulted more reliable than G4P, with a MARD of 10.0%, and a further decrease to 20% of the error due to blood-to-interstitial glucose kinetics.
Collapse
Affiliation(s)
- Andrea Facchinetti
- Department of Information Engineering, University of Padova, Via G.Gradenigo 6/B, 35131, Padua, Italy
| | - Simone Del Favero
- Department of Information Engineering, University of Padova, Via G.Gradenigo 6/B, 35131, Padua, Italy
| | - Giovanni Sparacino
- Department of Information Engineering, University of Padova, Via G.Gradenigo 6/B, 35131, Padua, Italy
| | - Claudio Cobelli
- Department of Information Engineering, University of Padova, Via G.Gradenigo 6/B, 35131, Padua, Italy.
| |
Collapse
|
14
|
Fabris C, Sparacino G, Sejling AS, Goljahani A, Duun-Henriksen J, Remvig LS, Juhl CB, Cobelli C. Hypoglycemia-related electroencephalogram changes assessed by multiscale entropy. Diabetes Technol Ther 2014; 16:688-94. [PMID: 24892361 DOI: 10.1089/dia.2013.0331] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
BACKGROUND Several clinical studies have shown that low blood glucose (BG) levels affect electroencephalogram (EEG) rhythms through the quantification of traditional indicators based on linear spectral analysis. Nonlinear measures used in the last decades to characterize the EEG in several physiopathological conditions have never been assessed in hypoglycemia. The present study investigates if properties of the EEG signal measured by nonlinear entropy-based algorithms are altered in a significant manner when a state of hypoglycemia is entered. SUBJECTS AND METHODS EEG was acquired from 19 patients with type 1 diabetes during a hyperinsulinemic-euglycemic-hypoglycemic clamp experiment. In parallel, BG was frequently monitored by the standard YSI glucose and lactate analyzer and used to identify two 1-h intervals corresponding to euglycemia and hypoglycemia, respectively. In each subject, the P3-C3 EEG derivation in the two glycemic intervals was assessed using the multiscale entropy (MSE) approach, obtaining measures of sample entropy (SampEn) at various temporal scales. The comparison of how signal irregularity measured by SampEn varies as the temporal scale increases in the two glycemic states provides information on how EEG complexity is affected by hypoglycemia. RESULTS For both glycemic states, the MSE analysis showed that SampEn increases at small time scales and then monotonically decreases as the time scale becomes larger. Comparing the two conditions, SampEn was higher in hypoglycemia only at medium time scales. CONCLUSIONS A decrease in the complexity of EEG occurs when a state of hypoglycemia is entered, because of a degradation of the EEG long-range temporal correlations. Thanks to its ability to assess nonlinear dynamics of the EEG signal, the MSE approach seems to be a useful tool to complement information brought by standard linear indicators and provide new insights on how hypoglycemia affects brain functioning.
Collapse
Affiliation(s)
- Chiara Fabris
- 1 Department of Information Engineering, University of Padova , Padova, Italy
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Fabris C, Facchinetti A, Sparacino G, Zanon M, Guerra S, Maran A, Cobelli C. Glucose variability indices in type 1 diabetes: parsimonious set of indices revealed by sparse principal component analysis. Diabetes Technol Ther 2014; 16:644-52. [PMID: 24956070 DOI: 10.1089/dia.2013.0252] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND Continuous glucose monitoring (CGM) time-series are often analyzed, retrospectively, to investigate glucose variability (GV), a risk factor for the development of complications in type 1 diabetes (T1D). In the literature, several tens of different indices for GV quantification have been proposed, but many of them carry very similar information. The aim of this article is to select a relatively small subset of GV indices from a wider pool of metrics, to obtain a parsimonious but still comprehensive description of GV in T1D datasets. MATERIALS AND METHODS A pool of 25 GV indices was evaluated on two CGM time-series datasets of 17 and 16 T1D subjects, respectively, collected during the European Union Seventh Framework Programme project "Diadvisor" (2008-2012) in two different clinical research centers using the Dexcom(®) (San Diego, CA) SEVEN(®) Plus. After the indices were centered and scaled, the Sparse Principal Component Analysis (SPCA) technique was used to determine a reduced set of metrics that allows preserving a high percentage of the variance of the whole original set. In order to assess whether or not the selected subset of GV indices is dataset-dependent, the analysis was applied to both datasets, as well as to the one obtained by merging them. RESULTS SPCA revealed that a subset of up to 10 different GV indices can be sufficient to preserve more than the 60% of the variance originally explained by all the 25 variables. It is remarkable that four of these GV indices (i.e., Index of Glycemic Control, percentage of Glycemic Risk Assessment Diabetes Equation score due to euglycemia, percentage Coefficient of Variation, and Low Blood Glucose Index) were selected for all the considered T1D datasets. CONCLUSIONS The SPCA methodology appears a suitable candidate to identify, among the large number of literature GV indices, subsets that allow obtaining a parsimonious, but still comprehensive, description of GV.
Collapse
Affiliation(s)
- Chiara Fabris
- 1 Department of Information Engineering, University of Padova , Padova, Italy
| | | | | | | | | | | | | |
Collapse
|
16
|
Cescon M, Johansson R. Linear Modeling and Prediction in Diabetes Physiology. DATA-DRIVEN MODELING FOR DIABETES 2014. [DOI: 10.1007/978-3-642-54464-4_9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
17
|
Zecchin C, Facchinetti A, Sparacino G, Dalla Man C, Manohar C, Levine JA, Basu A, Kudva YC, Cobelli C. Physical activity measured by physical activity monitoring system correlates with glucose trends reconstructed from continuous glucose monitoring. Diabetes Technol Ther 2013; 15:836-44. [PMID: 23944973 PMCID: PMC3781118 DOI: 10.1089/dia.2013.0105] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
BACKGROUND In type 1 diabetes mellitus (T1DM), physical activity (PA) lowers the risk of cardiovascular complications but hinders the achievement of optimal glycemic control, transiently boosting insulin action and increasing hypoglycemia risk. Quantitative investigation of relationships between PA-related signals and glucose dynamics, tracked using, for example, continuous glucose monitoring (CGM) sensors, have been barely explored. SUBJECTS AND METHODS In the clinic, 20 control and 19 T1DM subjects were studied for 4 consecutive days. They underwent low-intensity PA sessions daily. PA was tracked by the PA monitoring system (PAMS), a system comprising accelerometers and inclinometers. Variations on glucose dynamics were tracked estimating first- and second-order time derivatives of glucose concentration from CGM via Bayesian smoothing. Short-time effects of PA on glucose dynamics were quantified through the partial correlation function in the interval (0, 60 min) after starting PA. RESULTS Correlation of PA with glucose time derivatives is evident. In T1DM, the negative correlation with the first-order glucose time derivative is maximal (absolute value) after 15 min of PA, whereas the positive correlation is maximal after 40-45 min. The negative correlation between the second-order time derivative and PA is maximal after 5 min, whereas the positive correlation is maximal after 35-40 min. Control subjects provided similar results but with positive and negative correlation peaks anticipated of 5 min. CONCLUSIONS Quantitative information on correlation between mild PA and short-term glucose dynamics was obtained. This represents a preliminary important step toward incorporation of PA information in more realistic physiological models of the glucose-insulin system usable in T1DM simulators, in development of closed-loop artificial pancreas control algorithms, and in CGM-based prediction algorithms for generation of hypoglycemic alerts.
Collapse
Affiliation(s)
- Chiara Zecchin
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Andrea Facchinetti
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Giovanni Sparacino
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Chiara Dalla Man
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Chinmay Manohar
- Department of Internal Medicine, Division of Endocrinology and Metabolism, Mayo Clinic, Rochester, Minnesota
| | - James A. Levine
- Department of Internal Medicine, Division of Endocrinology and Metabolism, Mayo Clinic, Rochester, Minnesota
| | - Ananda Basu
- Department of Internal Medicine, Division of Endocrinology and Metabolism, Mayo Clinic, Rochester, Minnesota
| | - Yogish C. Kudva
- Department of Internal Medicine, Division of Endocrinology and Metabolism, Mayo Clinic, Rochester, Minnesota
| | - Claudio Cobelli
- Department of Information Engineering, University of Padova, Padova, Italy
| |
Collapse
|
18
|
Facchinetti A, Del Favero S, Sparacino G, Castle JR, Ward WK, Cobelli C. Modeling the glucose sensor error. IEEE Trans Biomed Eng 2013; 61:620-9. [PMID: 24108706 DOI: 10.1109/tbme.2013.2284023] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Continuous glucose monitoring (CGM) sensors are portable devices, employed in the treatment of diabetes, able to measure glucose concentration in the interstitium almost continuously for several days. However, CGM sensors are not as accurate as standard blood glucose (BG) meters. Studies comparing CGM versus BG demonstrated that CGM is affected by distortion due to diffusion processes and by time-varying systematic under/overestimations due to calibrations and sensor drifts. In addition, measurement noise is also present in CGM data. A reliable model of the different components of CGM inaccuracy with respect to BG (briefly, "sensor error") is important in several applications, e.g., design of optimal digital filters for denoising of CGM data, real-time glucose prediction, insulin dosing, and artificial pancreas control algorithms. The aim of this paper is to propose an approach to describe CGM sensor error by exploiting n multiple simultaneous CGM recordings. The model of sensor error description includes a model of blood-to-interstitial glucose diffusion process, a linear time-varying model to account for calibration and sensor drift-in-time, and an autoregressive model to describe the additive measurement noise. Model orders and parameters are identified from the n simultaneous CGM sensor recordings and BG references. While the model is applicable to any CGM sensor, here, it is used on a database of 36 datasets of type 1 diabetic adults in which n = 4 Dexcom SEVEN Plus CGM time series and frequent BG references were available simultaneously. Results demonstrates that multiple simultaneous sensor data and proper modeling allow dissecting the sensor error into its different components, distinguishing those related to physiology from those related to technology.
Collapse
|
19
|
Non-invasive continuous glucose monitoring with multi-sensor systems: a Monte Carlo-based methodology for assessing calibration robustness. SENSORS 2013; 13:7279-95. [PMID: 23736850 PMCID: PMC3715227 DOI: 10.3390/s130607279] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/02/2013] [Revised: 04/25/2013] [Accepted: 05/22/2013] [Indexed: 01/01/2023]
Abstract
In diabetes research, non-invasive continuous glucose monitoring (NI-CGM) devices represent a new and appealing frontier. In the last years, some multi-sensor devices for NI-CGM have been proposed, which exploit several sensors measuring phenomena of different nature, not only for measuring glucose related signals, but also signals reflecting some possible perturbing processes (temperature, blood perfusion). Estimation of glucose levels is then obtained combining these signals through a mathematical model which requires an initial calibration step exploiting one reference blood glucose (RBG) sample. Even if promising results have been obtained, especially in hospitalized volunteers, at present the temporal accuracy of NI-CGM sensors may suffer because of environmental and physiological interferences. The aim of this work is to develop a general methodology, based on Monte Carlo (MC) simulation, to assess the robustness of the calibration step used by NI-CGM devices against these disturbances. The proposed methodology is illustrated considering two examples: the first concerns the possible detrimental influence of sweat events, while the second deals with calibration scheduling. For implementing both examples, 45 datasets collected by the Solianis Multisensor system are considered. In the first example, the MC methodology suggests that no further calibration adjustments are needed after the occurrence of sweat events, because the “Multisensor+model” system is able to deal with the disturbance. The second case study shows how to identify the best time interval to update the model's calibration for improving the accuracy of the estimated glucose. The methodology proposed in this work is of general applicability and can be helpful in making those incremental steps in NI-CGM devices development needed to further improve their performance.
Collapse
|
20
|
Gonzalez C, Maury E, Barcos I, Gin H, Rigalleau V. Can continuous glucose monitoring systems predict glycemia? Diabetes Technol Ther 2012; 14:1030-2. [PMID: 22934799 DOI: 10.1089/dia.2012.0130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND We investigated whether the arrow on a continuous glucose monitoring system (CGMS) screen predicts the course of the capillary glucose level 15 min later. SUBJECTS AND METHODS Twenty-three patients with type 1 diabetes (age, 40±13 years; diabetes duration, 19±12 years; hemoglobin A1c, 8.5±1.5%) admitted for education in the use of a CGMS performed 242 observations: the arrow was noted at time 0, and the interstitial and capillary glucose levels were noted at time 0 and 15 min later. RESULTS The capillary glucose courses were -15±28 mg/dL after a descending arrow (n=55), +1±23 mg/dL after a stable arrow (n=147) (P<0.001 vs. descending), and +2±23 mg/dL after an ascending arrow (n=40) (P<0.01 vs. descending), with similar findings for the 67 observations after an interstitial glucose level <100 mg/dL. There were 4.5% grossly erroneous arrows: six descending with later increasing and five ascending with later decreasing capillary glucose. CONCLUSIONS Although there is a large room for improvement, the arrow on the CGMS screen does predict the decline in capillary glucose 15 min later.
Collapse
|
21
|
Italian contributions to the development of continuous glucose monitoring sensors for diabetes management. SENSORS 2012. [PMID: 23202020 PMCID: PMC3545591 DOI: 10.3390/s121013753] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
Monitoring glucose concentration in the blood is essential in the therapy of diabetes, a pathology which affects about 350 million people around the World (three million in Italy), causes more than four million deaths per year and consumes a significant portion of the budget of national health systems (10% in Italy). In the last 15 years, several sensors with different degree of invasiveness have been proposed to monitor glycemia in a quasi-continuous way (up to 1 sample/min rate) for relatively long intervals (up to 7 consecutive days). These continuous glucose monitoring (CGM) sensors have opened new scenarios to assess, off-line, the effectiveness of individual patient therapeutic plans from the retrospective analysis of glucose time-series, but have also stimulated the development of innovative on-line applications, such as hypo/hyper-glycemia alert systems and artificial pancreas closed-loop control algorithms. In this review, we illustrate some significant Italian contributions, both from industry and academia, to the growth of the CGM sensors research area. In particular, technological, algorithmic and clinical developments performed in Italy will be discussed and put in relation with the advances obtained in the field in the wider international research community.
Collapse
|
22
|
Zanon M, Sparacino G, Facchinetti A, Riz M, Talary MS, Suri RE, Caduff A, Cobelli C. Non-invasive continuous glucose monitoring: improved accuracy of point and trend estimates of the Multisensor system. Med Biol Eng Comput 2012; 50:1047-57. [PMID: 22722898 DOI: 10.1007/s11517-012-0932-6] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2011] [Accepted: 06/05/2012] [Indexed: 11/24/2022]
Abstract
Non-invasive continuous glucose monitoring (NI-CGM) sensors are still at an early stage of development, but, in the near future, they could become particularly appealing in diabetes management. Solianis Monitoring AG (Zurich, Switzerland) has proposed an approach for NI-CGM based on a multi-sensor concept, embedding primarily dielectric spectroscopy and optical sensors. This concept requires a mathematical model able to estimate glucose levels from the 150 channels directly measured through the Multisensor. A static multivariate linear regression model (with order and parameters common to the entire population of subjects) was proposed for such a scope (Caduff et al., Biosens Bioelectron 26:3794-3800, 2011). The aim of this work is to evaluate the accuracy in the estimation of glucose levels and trends that the NI-CGM Multisensor platform can achieve by exploiting different techniques for model identification, namely, ordinary least squares, subset variable selection, partial least squares and least absolute shrinkage and selection operator (LASSO). Data collected in human beings monitored for a total of 45 study days were used for model identification and model test. Several metrics of standard use in the diabetes scientific community to measure point and clinical accuracy of glucose sensors were used to assess the models. Results indicate that the LASSO technique is superior to the others shrinking many channel weights to zero thus leading to smoother glucose profiles and resulting in a more robust model to possible artifacts in the Multisensor data. Although, as expected, the performance of the NI-CGM system with the LASSO model is not yet comparable with that of enzyme-based needle glucose sensors, glucose trends are satisfactorily estimated. Considering the non-invasive nature of the multi-sensor platform, this result can have an immediate impact in the current clinical practice, e.g., to integrate sparse self-monitoring of blood glucose data with an indication of the glucose trend to aid the diabetic patient in dealing with, or even preventing in the short time scale, the threats of critical events such as hypoglycaemia.
Collapse
Affiliation(s)
- Mattia Zanon
- Department of Information Engineering, University of Padova, Padua, Italy
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Rawlings R, Yuan L, Shi H, Brehm W, Pop-Busui R, Nelson P. Dynamic Stress Factor (DySF): A Significant Predictor of Severe Hypoglycemic Events in Children with Type 1 Diabetes. JOURNAL OF DIABETES & METABOLISM 2012; 3:177. [PMID: 24349871 PMCID: PMC3859451 DOI: 10.4172/2155-6156.1000177] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Hemoglobin A1c (HbA1c) is the current standard used in the clinical treatment of patients with diabetes. However, it has been shown that patients with similar HbA1c values may have widely different fluctuations in blood glucose values over the same period of time, including time spent in hyper- and/or hypo-glycemia. Hence, there exists a need for quantitative measures that can supplement HbA1c in managing patients with diabetes. We introduce and compare the Dynamic Stress Factor, DySF, a newly developed metric that quantifies glycemic volatility based on patient-specific glucose transition density profiles with HbA1c and with currently used glucose variability metrics in predicting severe hypoglycemia in children with type 1 diabetes. DySF, the daily weighted number of large monotonic glycemic transitions that occur within one hour, was calculated for 441 total subjects with type 1 diabetes (146 children, aged 8-14 yrs) to assess the magnitude and frequency of glucose transitions per day. Severe hypoglycemic episodes (HE) were quantified for all subjects and evaluated against HbA1c and existing measures of glucose variability, including SD, MAGE, MODD, and CONGA using logistic regression models. DySF was found to be a predictor of severe HE in children (p = 0.018) with the likelihood of a child, aged 8-14 yrs, experiencing severe hypoglycemia increasing by up to 20% with decreasing values of up to 60% of DySF. Patients of any age who had one or multiple severe hypoglycemic episodes had on average a lower DySF when compared to those with no HE. Additionally, when considering mean glucose levels, DySF/mean was a preliminary predictor of severe HE in patients with HbA1c ≤ 6.5% (p = 0.062). DySF is a dynamic, quantitative, measure of daily glucose "volatility" that separates patients, within the same strata of HbA1c, into visually distinct patient profiles. DySF can be used as a preliminary predictor of clinically severe hypoglycemia in children and "well-controlled" patients with HbA1c ≤ 6.5%.
Collapse
Affiliation(s)
- Ra Rawlings
- Center for Computational Medicine and Bioinformatics, University of Michigan, USA ; Departments of Biophysics, University of Michigan, USA
| | - L Yuan
- Departments of Mathematics, University of Michigan, USA ; University of Michigan Program in Informatics, University of Michigan, USA
| | - H Shi
- University of Michigan Medical School, USA
| | - W Brehm
- Brehm Center for Diabetes Research, University of Michigan, USA
| | - R Pop-Busui
- Brehm Center for Diabetes Research, University of Michigan, USA ; Internal Medicine, Division of Metabolism, Endocrinology and Diabetes, University of Michigan, USA
| | - Pw Nelson
- Center for Computational Medicine and Bioinformatics, University of Michigan, USA
| |
Collapse
|