1
|
Epstein RH, Nemes R, Renew JR, Brull SJ. Area under the curve and amplitude of the compound motor action potential are clinically interchangeable quantitative measures of neuromuscular block: a method comparison study. BJA OPEN 2024; 11:100293. [PMID: 38974718 PMCID: PMC11226963 DOI: 10.1016/j.bjao.2024.100293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2024] [Accepted: 05/22/2024] [Indexed: 07/09/2024]
Abstract
Background Current guidelines recommend quantitative neuromuscular block monitoring during neuromuscular blocking agent administration. Monitors using surface electromyography (EMG) determine compound motor action potential (cMAP) amplitude or area under the curve (AUC). Rigorous evaluation of the interchangeability of these methods is lacking but necessary for clinical and research assurance that EMG interpretations of the depth of neuromuscular block are not affected by the methodology. Methods Digitised EMG waveforms were studied from 48 patients given rocuronium during two published studies. The EMG amplitudes and AUCs were calculated pairwise from all cMAPs classified as valid by visual inspection. Ratios of the first twitch (T1) to the control T1 before administration of rocuronium (T1c) and train-of-four ratios (TOFRs) were compared using repeated measures Bland-Altman analysis. Results Among the 2419 paired T1/T1c differences where the average T1/T1c was ≤0.2, eight (0.33%) were outside prespecified clinical limits of agreement (-0.148 to 0.164). Among the 1781 paired TOFR differences where the average TOFR was ≥0.8, 70 (3.93%) were outside the prespecified clinical limits of agreement ((-0.109 to 0.134). Among all 7286 T1/T1c paired differences, the mean bias was 0.32 (95% confidence interval 0.202-0.043), and among all 5559 paired TOFR differences, the mean bias was 0.011 (95% confidence interval 0.0050-0.017). Among paired T1/T1c and TOFR differences, Lin's concordance correlation coefficients were 0.98 and 0.995, respectively. Repeatability coefficients for T1/T1c and TOFR were <0.08, with no differences between methods. Conclusions Quantitative assessment neuromuscular block depth is clinically interchangeable when calculated using cMAP amplitude or the AUC.
Collapse
Affiliation(s)
- Richard H. Epstein
- Department of Anesthesiology, Perioperative Medicine & Pain Management, University of Miami, Miller School of Medicine, Miami, FL, USA
| | - Réka Nemes
- Department of Anesthesiology and Intensive Care, University of Debrecen, Debrecen, Hungary
| | - Johnathan R. Renew
- Department of Anesthesiology and Perioperative Medicine, Mayo Clinic College of Medicine and Science, Jacksonville, FL, USA
| | - Sorin J. Brull
- Department of Anesthesiology and Perioperative Medicine, Mayo Clinic College of Medicine and Science, Jacksonville, FL, USA
| |
Collapse
|
2
|
Cade A, Turnbull PRK. Classification of short and long term mild traumatic brain injury using computerized eye tracking. Sci Rep 2024; 14:12686. [PMID: 38830966 PMCID: PMC11148176 DOI: 10.1038/s41598-024-63540-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Accepted: 05/29/2024] [Indexed: 06/05/2024] Open
Abstract
Accurate, and objective diagnosis of brain injury remains challenging. This study evaluated useability and reliability of computerized eye-tracker assessments (CEAs) designed to assess oculomotor function, visual attention/processing, and selective attention in recent mild traumatic brain injury (mTBI), persistent post-concussion syndrome (PPCS), and controls. Tests included egocentric localisation, fixation-stability, smooth-pursuit, saccades, Stroop, and the vestibulo-ocular reflex (VOR). Thirty-five healthy adults performed the CEA battery twice to assess useability and test-retest reliability. In separate experiments, CEA data from 55 healthy, 20 mTBI, and 40 PPCS adults were used to train a machine learning model to categorize participants into control, mTBI, or PPCS classes. Intraclass correlation coefficients demonstrated moderate (ICC > .50) to excellent (ICC > .98) reliability (p < .05) and satisfactory CEA compliance. Machine learning modelling categorizing participants into groups of control, mTBI, and PPCS performed reasonably (balanced accuracy control: 0.83, mTBI: 0.66, and PPCS: 0.76, AUC-ROC: 0.82). Key outcomes were the VOR (gaze stability), fixation (vertical error), and pursuit (total error, vertical gain, and number of saccades). The CEA battery was reliable and able to differentiate healthy, mTBI, and PPCS patients reasonably well. While promising, the diagnostic model accuracy should be improved with a larger training dataset before use in clinical environments.
Collapse
Affiliation(s)
- Alice Cade
- School of Optometry and Vision Science, The University of Auckland, Private Bag 92019, Auckland, 1023, New Zealand.
- New Zealand College of Chiropractic, Auckland, New Zealand.
| | - Philip R K Turnbull
- School of Optometry and Vision Science, The University of Auckland, Private Bag 92019, Auckland, 1023, New Zealand
| |
Collapse
|
3
|
Hirooka M, Ogawa S, Koizumi Y, Yoshida Y, Goto T, Yasuda S, Yamahira M, Tamai T, Kuromatsu R, Matsuzaki T, Suehiro T, Kamada Y, Sumida Y, Hiasa Y, Toyoda H, Kumada T. iATT liver fat quantification for steatosis grading by referring to MRI proton density fat fraction: a multicenter study. J Gastroenterol 2024; 59:504-514. [PMID: 38553657 PMCID: PMC11128405 DOI: 10.1007/s00535-024-02096-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Accepted: 03/03/2024] [Indexed: 05/27/2024]
Abstract
BACKGROUND Several preliminary reports have suggested the utility of ultrasound attenuation coefficient measurements based on B-mode ultrasound, such as iATT, for diagnosing steatotic liver disease. Nonetheless, evidence supporting such utility is lacking. This prospective study aimed to investigate whether iATT is highly concordant with magnetic resonance imaging (MRI)-based proton density fat fraction (MRI-PDFF) and could well distinguish between steatosis grades. METHODS A cohort of 846 individuals underwent both iATT and MRI-PDFF assessments. Steatosis grade was defined as grade 0 with MRI-PDFF < 5.2%, grade 1 with 5.2% MRI-PDFF < 11.3%, grade 2 with 11.3% MRI-PDFF < 17.1%, and grade 3 with MRI-PDFF of 17.1%. The reproducibility of iATT and MRI-PDFF was evaluated using the Bland-Altman analysis and intraclass correlation coefficients, whereas the diagnostic performance of each steatosis grade was examined using receiver operating characteristic analysis. RESULTS The Bland-Altman analysis indicated excellent reproducibility with minimal fixed bias between iATT and MRI-PDFF. The area under the curve for distinguishing steatosis grades 1, 2, and 3 were 0.887, 0.882, and 0.867, respectively. A skin-to-capsula distance of ≥ 25 mm was identified as the only significant factor causing the discrepancy. No interaction between MRI-logPDFF and MRE-LSM on iATT values was observed. CONCLUSIONS Compared to MRI-PDFF, iATT showed excellent diagnostic accuracy in grading steatosis. iATT could be used as a diagnostic tool instead of MRI in clinical practice and trials. Trial registration This study was registered in the UMIN Clinical Trials Registry (UMIN000047411).
Collapse
Affiliation(s)
- Masashi Hirooka
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Ehime, 791-0295, Japan.
| | - Sadanobu Ogawa
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Japan
| | - Yohei Koizumi
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Ehime, 791-0295, Japan
| | - Yuichi Yoshida
- Department of Gastroenterology and Hepatology, Suita Municipal Hospital, Suita, Japan
| | - Tatsuya Goto
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Japan
| | - Satoshi Yasuda
- Department of Gastroenterology, Ogaki Municipal Hospital, Ogaki, Japan
| | - Masahiro Yamahira
- Department of Clinical Laboratory Medicine, Suita Municipal Hospital, Suita, Japan
| | - Tsutomu Tamai
- Department of Gastroenterology, Kagoshima City Hospital, Kagoshima, Japan
| | - Ryoko Kuromatsu
- Division of Gastroenterology, Department of Medicine, Kurume University School of Medicine, Kurume, Japan
| | - Toshihisa Matsuzaki
- Department of Gastroenterology, Sasebo City General Hospital, Sasebo, Nagasaki, Japan
| | - Tomoyuki Suehiro
- Clinical Research Center, National Hospital Organization Nagasaki Medical Center, Omura, Nagasaki, Japan
| | - Yoshihiro Kamada
- Department of Advanced Metabolic Hepatology, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Yoshio Sumida
- Graduate School of Healthcare Management, International University of Healthcare and Welfare, Tokyo, Japan
| | - Yoichi Hiasa
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Ehime, 791-0295, Japan
| | - Hidenori Toyoda
- Department of Gastroenterology, Ogaki Municipal Hospital, Ogaki, Japan
| | - Takashi Kumada
- Department of Nursing, Faculty of Nursing, Gifu Kyoritsu University, Ogaki, Japan
| |
Collapse
|
4
|
Lapsina S, Riond B, Hofmann-Lehmann R, Stirn M. Canine Cerebrospinal Fluid Analysis Using Two New Automated Techniques: The Sysmex XN-V Body Fluid Mode and an Artificial-Intelligence-Based Algorithm. Animals (Basel) 2024; 14:1655. [PMID: 38891702 PMCID: PMC11171029 DOI: 10.3390/ani14111655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 05/17/2024] [Accepted: 05/28/2024] [Indexed: 06/21/2024] Open
Abstract
Cerebrospinal fluid analysis is an important diagnostic test when assessing a neurological canine patient. For this analysis, the total nucleated cell count and differential cell counts are routinely taken, but both involve time-consuming manual methods. To investigate faster automated methods, in this study, the Sysmex XN-V body fluid mode and the deep-learning-based algorithm generated by the Olympus VS200 slide scanner were compared with the manual methods in 161 canine cerebrospinal fluid samples for the total nucleated cell count and in 65 samples with pleocytosis for the differential counts. Following incorrect gating by the Sysmex body fluid mode, all samples were reanalyzed with manually set gates. The Sysmex body fluid mode then showed a mean bias of 15.19 cells/μL for the total nucleated cell count and mean biases of 4.95% and -4.95% for the two-part differential cell count, while the deep-learning-based algorithm showed mean biases of -7.25%, -0.03% and 7.27% for the lymphocytes, neutrophils and monocytoid cells, respectively. Based on our findings, we propose that the automated Sysmex body fluid mode be used to measure the total nucleated cell count in canine cerebrospinal fluid samples after making adjustments to the predefined settings from the manufacturer. However, the two-part differential count of the Sysmex body fluid mode and the deep-learning-based algorithm require some optimization.
Collapse
Affiliation(s)
- Sandra Lapsina
- Clinical Laboratory, Department of Clinical Diagnostics and Services, Vetsuisse Faculty, University of Zurich, Winterthurerstrasse 260, CH-8057 Zurich, Switzerland; (S.L.); (R.H.-L.)
- SIA Laboklin, Fridriha Candera iela 4, LV-1046 Riga, Latvia
| | - Barbara Riond
- Clinical Laboratory, Department of Clinical Diagnostics and Services, Vetsuisse Faculty, University of Zurich, Winterthurerstrasse 260, CH-8057 Zurich, Switzerland; (S.L.); (R.H.-L.)
| | - Regina Hofmann-Lehmann
- Clinical Laboratory, Department of Clinical Diagnostics and Services, Vetsuisse Faculty, University of Zurich, Winterthurerstrasse 260, CH-8057 Zurich, Switzerland; (S.L.); (R.H.-L.)
| | - Martina Stirn
- Clinical Laboratory, Department of Clinical Diagnostics and Services, Vetsuisse Faculty, University of Zurich, Winterthurerstrasse 260, CH-8057 Zurich, Switzerland; (S.L.); (R.H.-L.)
- Roche Pharma Research and Early Development, Pharmaceutical Sciences, Roche Innovation Center, 4070 Basel, Switzerland
| |
Collapse
|
5
|
Ishigaki T, Kubo H, Yoshida K, Shimizu N, Ogawa T. Validity and reliability of the 2-min step test in individuals with stroke and lower-limb musculoskeletal disorders. FRONTIERS IN REHABILITATION SCIENCES 2024; 5:1384369. [PMID: 38690193 PMCID: PMC11058829 DOI: 10.3389/fresc.2024.1384369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Accepted: 04/01/2024] [Indexed: 05/02/2024]
Abstract
Introduction We investigated the reliability and validity of the 2-min step test (2MST) for assessing the exercise endurance of individuals with stroke and lower-limb musculoskeletal disorders. Participants and methods The participants were 39 individuals with stroke and 42 with lower-limb musculoskeletal disorders (mainly hip fractures) from the convalescent rehabilitation wards of four hospitals. The concurrent validity and congruence between the 2MST and the 6-min walk test (6MWT) and construct validity by hypotheses testing, including mobility and lower limb muscle strength, were also confirmed. A subset of participants (stroke-group, n = 15; musculoskeletal-group, n = 19) underwent a retest 2MST for our evaluation of relative and absolute reliability using the intraclass correlation coefficient (ICC1,1) and Bland-Altman plot. Results Both groups showed a moderate correlation between the 2MST and 6MWT (ρ = 0.55-0.60), but the congruence was not sufficient. The 6MWT was correlated with mobility in both groups and with muscle strength in the stroke group, whereas the 2MST did not show a significant correlation with mobility. The relative reliability was excellent in both groups (ICC1,1 > 0.9). In terms of absolute reliability, the width of the limit of agreement was 18.8% for the stroke group and 15.4% for the musculoskeletal group, relative to their respective sample means of 2MST. A fixed bias was identified in the stroke group, in which step counts increased by 6.5 steps upon retesting. Discussion Our analyses revealed that the 2MST is a valid and reliable tool for assessing the exercise endurance of individuals with stroke or lower-limb musculoskeletal disorders. However, it is necessary to validate the absolute reliability observed herein by using a larger sample size. In addition, when assessing the exercise endurance of individuals with stroke, it may be necessary to consider the potential bias of an increased step count during retesting.
Collapse
Affiliation(s)
- Tomoya Ishigaki
- Department of Physical Therapy, Faculty of Rehabilitation Sciences, Nagoya Gakuin University, Aichi, Japan
| | - Hiroki Kubo
- Department of Physical Therapy, Faculty of Nursing and Rehabilitation, Konan Women’s University, Hyogo, Japan
| | - Keishi Yoshida
- Department of Rehabilitation, Senri-Chuo Hospital, Osaka, Japan
| | - Natsuki Shimizu
- Department of Physical Therapy, Faculty of Health and Medical Care, Saitama Medical University, Saitama, Japan
| | - Tatsuya Ogawa
- Department of Rehabilitation, Nishiyamato Rehabilitation Hospital, Nara, Japan
| |
Collapse
|
6
|
Cheong I, Otero Castro V, Sosa FA, Tort Oribe B, Früchtenicht MF, Tamagnone FM, Merlo PM. Passive leg raising test using the carotid flow velocity-time integral to predict fluid responsiveness. J Ultrasound 2024; 27:97-104. [PMID: 37668901 PMCID: PMC10909041 DOI: 10.1007/s40477-023-00824-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 08/08/2023] [Indexed: 09/06/2023] Open
Abstract
PURPOSE The passive leg raising test (PLR) is a noninvasive method widely adopted to assess fluid responsiveness. We propose to explore if changes in the carotid flow assessed by echo-Doppler can predict fluid responsiveness after a PLR. METHODS We conducted a performance diagnostic study in two intensive care units from Argentina between February and April 2022. We included patients with signs of tissular hypoperfusion that required fluid resuscitation. We labeled the patients as fluid responders when we measured, after a fluid bolus, an increase greater than 15% in the left ventricle outflow tract (LVOT) VTI in an apical 5-chamber view and we compared those results with the carotid flow (CF) velocity-time integral (VTI) from the left supraclavicular region in a semi-recumbent position and during the PLR. RESULTS Of the 62 eligible patients, 50 patients (80.6%) were included. The area under the ROC curve for a change in CF VTI during the PLR test was 0.869 (95% CI 0.743-0.947). An increase of at least of 11% in the CF VTI with the PLR predicted fluid-responsiveness with a sensitivity of 77.3% (95% CI 54.6-92.2%) and specificity of 78.6% (95% CI 59-91.7%). The positive predictive value was 73.9% (95% CI 57.4-85.6%) and the negative predictive value was 81.5% (95% CI 66.5-90.7%). The positive likelihood ratio was 3.61 and the negative likelihood ratio was 0.29. CONCLUSION An increase greater than 11% in CF VTI after a PLR may be useful to predict fluid responsiveness among critically ill patients.
Collapse
Affiliation(s)
- Issac Cheong
- Department of Critical Care Medicine, Sanatorio de Los Arcos, Juan B. Justo 909, CABA, Buenos Aires, Argentina.
- Argentinian Critical Care Ultrasonography Association (ASARUC), Buenos Aires, Argentina.
| | - Victoria Otero Castro
- Department of Critical Care Medicine, Sanatorio de Los Arcos, Juan B. Justo 909, CABA, Buenos Aires, Argentina
| | - Fernando Ariel Sosa
- Argentinian Critical Care Ultrasonography Association (ASARUC), Buenos Aires, Argentina
- Department of Critical Care Medicine, Hospital Alemán, Buenos Aires, Argentina
| | - Bárbara Tort Oribe
- Department of Critical Care Medicine, Hospital Alemán, Buenos Aires, Argentina
| | | | | | - Pablo Martín Merlo
- Argentinian Critical Care Ultrasonography Association (ASARUC), Buenos Aires, Argentina
| |
Collapse
|
7
|
Rasmussen AM, Friismose AI, Mussmann B, Lagerstrand K, Harbo FSG, Jensen J. Repeatability of diffusion-based stiffness prediction - A healthy volunteer study. Radiography (Lond) 2024; 30:524-530. [PMID: 38262191 DOI: 10.1016/j.radi.2024.01.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 01/03/2024] [Accepted: 01/10/2024] [Indexed: 01/25/2024]
Abstract
INTRODUCTION The study investigated the repeatability of brain diffusion-based stiffness prediction (DWIstiff) in healthy volunteers. METHODS Thirty-one healthy volunteers were examined with DWIstiff using two different sets of b-values: b200-1500 s/mm2 (DWIstiff, 1500) and b200-1000 s/mm2 (DWIstiff, 1000). Each b-value set was scanned twice per imaging session without repositioning the participants. DWIstiff images were reconstructed from each set. Two observers delineated regions of interest (ROIs) on each DWIstiff image. The repeatability coefficient (RC), coefficient of variation (CV), inter- and intraobserver agreement were calculated. RESULTS After excluding three participants due to image artifacts, the study included twenty-eight volunteers (mean age (range)) 37 years (24-62), 10 males, 18 females). For DWIstiff, 1500, the lowest and the highest RCs were in the parietal lobe (0.52) and respectively the brain stem (1.17). The lowest RC for DWIstiff, 1000 was in the frontal lobe (0.42) and the highest in the brain stem (1.58). The CV for whole brain measurements was 3.83 % for DWIstiff, 1500 and 4.93 % for DWIstiff, 1000. The Bland‒Altman (BA) limits of agreement (LoA) for the intraobserver agreement of DWIstiff, 1500 were -0.90 to 1.06 and respectively -0.78 to 0.88 for DWIstiff, 1000. Regarding interobserver agreement, the LoA were -0.85 to 0.94 for DWIstiff, 1500 and -0.61 to 0.66 for DWIstiff, 1000. CONCLUSION DWIstiff is a precise technique with some observer dependence. Repeatability is higher for DWIstiff, 1000 s/mm2 than for DWIstiff 1500 s/mm2. IMPLICATIONS FOR PRACTICE Our findings suggest that DWIstiff can reliably detect stiffness changes larger than 4.93 % in healthy volunteers. Further studies should investigate whether the repeatability of DWIstiff may be affected by the presence of pathology such as a brain tumor.
Collapse
Affiliation(s)
- A-M Rasmussen
- Department of Radiology, Odense University Hospital, Odense, Denmark; Research and Innovation Unit of Radiology, University of Southern Denmark, Odense, Denmark
| | - A I Friismose
- Department of Radiology, Odense University Hospital, Odense, Denmark; Research and Innovation Unit of Radiology, University of Southern Denmark, Odense, Denmark.
| | - B Mussmann
- Department of Radiology, Odense University Hospital, Odense, Denmark; Research and Innovation Unit of Radiology, University of Southern Denmark, Odense, Denmark; Department of Life Sciences and Health, Radiography, Oslo Metropolitan University, Oslo, Norway
| | - K Lagerstrand
- Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - F S G Harbo
- Department of Radiology, Odense University Hospital, Odense, Denmark
| | - J Jensen
- Department of Radiology, Odense University Hospital, Odense, Denmark; Research and Innovation Unit of Radiology, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
8
|
Jahani B, Vaidya R, Jin JM, Aboytes DA, Broz KS, Krothapalli S, Pujari B, Baig WM, Tang SY. Assessment of bovine cortical bone fracture behavior using impact microindentation as a surrogate of fracture toughness. JBMR Plus 2024; 8:ziad012. [PMID: 38505533 PMCID: PMC10945719 DOI: 10.1093/jbmrpl/ziad012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 11/14/2023] [Accepted: 12/05/2023] [Indexed: 03/21/2024] Open
Abstract
The fracture behavior of bone is critically important for evaluating its mechanical competence and ability to resist fractures. Fracture toughness is an intrinsic material property that quantifies a material's ability to withstand crack propagation under controlled conditions. However, properly conducting fracture toughness testing requires the access to calibrated mechanical load frames and the destructive testing of bone samples, and therefore fracture toughness tests are clinically impractical. Impact microindentation mimicks certain aspects of fracture toughness measurements, but its relationship with fracture toughness remains unknown. In this study, we aimed to compare measurements of notched fracture toughness and impact microindentation in fresh and boiled bovine bone. Skeletally mature bovine bone specimens (n = 48) were prepared, and half of them were boiled to denature the organic matrix, while the other half remained preserved in frozen conditions. All samples underwent a notched fracture toughness test to determine their resistance to crack initiation (KIC) and an impact microindentation test using the OsteoProbe to obtain the Bone Material Strength index (BMSi). Boiling the bone samples increased the denatured collagen content, while mineral density and porosity remained unaffected. The boiled bones also showed significant reduction in both KIC (P < .0001) and the average BMSi (P < .0001), leading to impaired resistance of bone to crack propagation. Remarkably, the average BMSi exhibited a high correlation with KIC (r = 0.86; P < .001). A ranked order difference analysis confirmed the excellent agreement between the 2 measures. This study provides the first evidence that impact microindentation could serve as a surrogate measure for bone fracture behavior. The potential of impact microindentation to assess bone fracture resistance with minimal sample disruption could offer valuable insights into bone health without the need for cumbersome testing equipment and sample destruction.
Collapse
Affiliation(s)
- Babak Jahani
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO 63110, United States
| | - Rachana Vaidya
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO 63110, United States
| | - James M Jin
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO 63110, United States
| | - Donald A Aboytes
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO 63110, United States
| | - Kaitlyn S Broz
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO 63110, United States
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis, MO 63110, United States
| | - Siva Krothapalli
- School of Medicine, St Louis University, MO 63104, United States
| | - Bhanuteja Pujari
- School of Medicine, St Louis University, MO 63104, United States
| | - Walee M Baig
- Department of Biology and Environmental Health, Missouri Southern State University, Joplin, MO 64801, United States
| | - Simon Y Tang
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO 63110, United States
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis, MO 63110, United States
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO 63130, United States
| |
Collapse
|
9
|
Liang H, Wang JY, Liang Y, Shao XF, Ding YL, Jia HQ. Agreement of zero-heat-flux thermometry with the oesophageal and tympanic core temperature measurement in patient receiving major surgery. J Clin Monit Comput 2024; 38:197-203. [PMID: 37792140 PMCID: PMC10879315 DOI: 10.1007/s10877-023-01078-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Accepted: 09/12/2023] [Indexed: 10/05/2023]
Abstract
To identify and prevent perioperative hypothermia, most surgical patients require a non-invasive, accurate, convenient, and continuous core temperature method, especially for patients undergoing major surgery. This study validated the precision and accuracy of a cutaneous zero-heat-flux thermometer and its performance in detecting intraoperative hypothermia. Adults undergoing major non-cardiac surgeries with general anaesthesia were enrolled in the study. Core temperatures were measured with a zero-heat-flux thermometer, infrared tympanic membrane thermometer, and oesophagal monitoring at 15-minute intervals. Taking the average value of temperature measured in the tympanic membrane and oesophagus as a reference, we assessed the agreement using the Bland-Altman analysis and linear regression methods. Sensitivity, specificity, and predictive values of detecting hypothermia were estimated. 103 patients and one thousand sixty-eight sets of paired temperatures were analyzed. The mean difference between zero-heat-flux and the referenced measurements was -0.03 ± 0.25 °C, with 95% limits of agreement (-0.52 °C, 0.47 °C) was narrow, with 94.5% of the differences within 0.5 °C. Lin's concordance correlation coefficient was 0.90 (95%CI 0.89-0.92). The zero-heat-flux thermometry detected hypothermia with a sensitivity of 82% and a specificity of 90%. The zero-heat-flux thermometer is in good agreement with the reference core temperature based on tympanic and oesophagal temperature monitoring in patients undergoing major surgeries, and appears high performance in detecting hypothermia.
Collapse
Affiliation(s)
- Hao Liang
- Department of Anesthesiology, The Fourth Hospital Of Hebei Medical University, Shijiazhuang, Hebei, China
| | - Jing-Yan Wang
- Department of ENT, Affiliated Hospital Of Hebei University, Baoding, Hebei, China
| | - Yan Liang
- Department of Obstetrics, The NO.1 Central Hospital Of Baoding City, Baoding, Hebei, China
| | - Xin-Feng Shao
- Department of Anesthesiology, The NO.1 Central Hospital Of Baoding City, Baoding, Hebei, China
| | - Yan-Ling Ding
- Department of Anesthesiology, The NO.1 Central Hospital Of Baoding City, Baoding, Hebei, China
| | - Hui-Qun Jia
- Department of Anesthesiology, The Fourth Hospital Of Hebei Medical University, Shijiazhuang, Hebei, China.
| |
Collapse
|
10
|
Gooderick J, Wood T, Abbott W, Hayes M, Maxwell N. Does a self-reported sleep duration reflect actigraphy reported sleep duration in female football players? SCI MED FOOTBALL 2024:1-7. [PMID: 38174382 DOI: 10.1080/24733938.2023.2297903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 12/12/2023] [Indexed: 01/05/2024]
Abstract
Sleep is often compromised in female athletes, and the monitoring of female athletes' sleep is an important preventative and educational tool. With self-reporting of sleep common practice for athletes as part of a daily wellness assessment, there is a need to understand whether sleep indices are being reported accurately, and thus whether self-report data are useful. This study aimed to compare the agreement between self-reported and actigraphy reported sleep duration in female football players, with the intention of informing best practice for athlete monitoring. Twenty-two female footballers (mean age 19.5 ± 1.3 years) provided a daily self-report across 7 days, whilst also wearing an actigraph across the same testing period. Agreement between the two measures was assessed using Bland-Altman limits of agreement, with acceptable limits of agreement defined as <30 minutes. Results showed evident disagreement between the two methods, with a mean bias of -0.54 (32 min, 95% CI -0.66 to -0.43) and a potential disagreement range of over 2 h (Lower 95% limits of agreement -1.49 to upper 95% limits of agreement 0.40). Coaches using self-reported sleep durations as a monitoring tool for female footballers should interpret the results with caution and be aware of the potential for inaccuracies in this measure. As such, where possible, coaches should consider other methods of sleep monitoring, rather than solely relying on a self-report, to ensure they are operating with optimal practice within situational constraints.
Collapse
Affiliation(s)
| | - Toby Wood
- School of Sport, University of Brighton, Eastbourne, UK
| | - Will Abbott
- School of Sport, University of Brighton, Eastbourne, UK
| | - Mark Hayes
- School of Sport, University of Brighton, Eastbourne, UK
| | - Neil Maxwell
- School of Sport, University of Brighton, Eastbourne, UK
| |
Collapse
|
11
|
Martin KT, Xin Y, Gaulton TG, Victor M, Santiago RR, Kim T, Morais CCA, Kazimi AA, Connell M, Gerard SE, Herrmann J, Mueller AL, Lenart A, Shen J, Khan SS, Petrov M, Reutlinger K, Rozenberg K, Amato M, Berra L, Cereda M. Electrical Impedance Tomography Identifies Evolution of Regional Perfusion in a Porcine Model of Acute Respiratory Distress Syndrome. Anesthesiology 2023; 139:815-826. [PMID: 37566686 PMCID: PMC10840641 DOI: 10.1097/aln.0000000000004731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/13/2023]
Abstract
BACKGROUND Bedside electrical impedance tomography could be useful to visualize evolving pulmonary perfusion distributions when acute respiratory distress syndrome worsens or in response to ventilatory and positional therapies. In experimental acute respiratory distress syndrome, this study evaluated the agreement of electrical impedance tomography and dynamic contrast-enhanced computed tomography perfusion distributions at two injury time points and in response to increased positive end-expiratory pressure (PEEP) and prone position. METHODS Eleven mechanically ventilated (VT 8 ml · kg-1) Yorkshire pigs (five male, six female) received bronchial hydrochloric acid (3.5 ml · kg-1) to invoke lung injury. Electrical impedance tomography and computed tomography perfusion images were obtained at 2 h (early injury) and 24 h (late injury) after injury in supine position with PEEP 5 and 10 cm H2O. In eight animals, electrical impedance tomography and computed tomography perfusion imaging were also conducted in the prone position. Electrical impedance tomography perfusion (QEIT) and computed tomography perfusion (QCT) values (as percentages of image total) were compared in eight vertical regions across injury stages, levels of PEEP, and body positions using mixed-effects linear regression. The primary outcome was agreement between QEIT and QCT, defined using limits of agreement and Pearson correlation coefficient. RESULTS Pao2/Fio2 decreased over the course of the experiment (healthy to early injury, -253 [95% CI, -317 to -189]; early to late injury, -88 [95% CI, -151 to -24]). The limits of agreement between QEIT and QCT were -4.66% and 4.73% for the middle 50% quantile of average regional perfusion, and the correlation coefficient was 0.88 (95% CI, 0.86 to 0.90]; P < 0.001). Electrical impedance tomography and computed tomography showed similar perfusion redistributions over injury stages and in response to increased PEEP. QEIT redistributions after positional therapy underestimated QCT in ventral regions and overestimated QCT in dorsal regions. CONCLUSIONS Electrical impedance tomography closely approximated computed tomography perfusion measures in experimental acute respiratory distress syndrome, in the supine position, over injury progression and with increased PEEP. Further validation is needed to determine the accuracy of electrical impedance tomography in measuring perfusion redistributions after positional changes. EDITOR’S PERSPECTIVE
Collapse
Affiliation(s)
- Kevin T Martin
- Department of Anesthesia and Perioperative Care, University of California San Francisco, CA, USA
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA, USA
| | - Yi Xin
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA, USA
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Timothy G Gaulton
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA, USA
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Marcus Victor
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
- Electronics Engineering Division, Aeronautics Institute of Technology, São Paulo, Brazil
| | - Roberta R Santiago
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Taehwan Kim
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA, USA
| | - Caio C A Morais
- Department of Physical Therapy, Federal University of Pernambuco, Recife, Brazil
| | - Aubrey A Kazimi
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA, USA
| | - Marc Connell
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA, USA
- University of Pittsburgh, School of Medicine, Pittsburgh, PA, USA
| | - Sarah E Gerard
- Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, IA, USA
| | - Jacob Herrmann
- Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, IA, USA
| | - Ariel L Mueller
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Austin Lenart
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA, USA
| | - Jiacheng Shen
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA, USA
| | - Sherbano S Khan
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA, USA
| | - Mihail Petrov
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA, USA
| | - Kristan Reutlinger
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA, USA
| | - Karina Rozenberg
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA, USA
| | - Marcelo Amato
- Department of Cardio-Pulmonary, University of São Paulo, São Paulo, Brazil
| | - Lorenzo Berra
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Maurizio Cereda
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA, USA
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| |
Collapse
|
12
|
Anand R, McLeese R, Busby J, Stewart J, Clarke M, Man WDC, Bradley J. Unsupervised home spirometry versus supervised clinic spirometry for respiratory disease: a systematic methodology review and meta-analysis. Eur Respir Rev 2023; 32:220248. [PMID: 37673426 PMCID: PMC10481332 DOI: 10.1183/16000617.0248-2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 05/31/2023] [Indexed: 09/08/2023] Open
Abstract
BACKGROUND The number of patients completing unsupervised home spirometry has recently increased due to more widely available portable technology and the COVID-19 pandemic, despite a lack of solid evidence to support it. This systematic methodology review and meta-analysis explores quantitative differences in unsupervised spirometry compared with spirometry completed under professional supervision. METHODS We searched four databases to find studies that directly compared unsupervised home spirometry with supervised clinic spirometry using a quantitative comparison (e.g. Bland-Altman). There were no restrictions on clinical condition. The primary outcome was measurement differences in common lung function parameters (forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC)), which were pooled to calculate overall mean differences with associated limits of agreement (LoA) and confidence intervals (CI). We used the I2 statistic to assess heterogeneity, the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool to assess risk of bias and the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach to assess evidence certainty for the meta-analyses. The review has been registered with PROSPERO (CRD42021272816). RESULTS 3607 records were identified and screened, with 155 full texts assessed for eligibility. We included 28 studies that quantitatively compared spirometry measurements, 17 of which reported a Bland-Altman analysis for FEV1 and FVC. Overall, unsupervised spirometry produced lower values than supervised spirometry for both FEV1 with wide variability (mean difference -107 mL; LoA= -509, 296; I2=95.8%; p<0.001; very low certainty) and FVC (mean difference -184 mL, LoA= -1028, 660; I2=96%; p<0.001; very low certainty). CONCLUSIONS Analysis under the conditions of the included studies indicated that unsupervised spirometry is not interchangeable with supervised spirometry for individual patients owing to variability and underestimation.
Collapse
Affiliation(s)
- Rohan Anand
- Wellcome-Wolfson Institute for Experimental Medicine, Queen's University Belfast, Belfast, UK
| | - Rebecca McLeese
- Wellcome-Wolfson Institute for Experimental Medicine, Queen's University Belfast, Belfast, UK
| | - John Busby
- Centre for Public Health, Queen's University Belfast, Belfast, UK
| | - Jonathan Stewart
- Wellcome-Wolfson Institute for Experimental Medicine, Queen's University Belfast, Belfast, UK
| | - Mike Clarke
- Centre for Public Health, Queen's University Belfast, Belfast, UK
| | - William D-C Man
- Royal Brompton and Harefield Hospitals, Guy's and St. Thomas' NHS Foundation Trust, London, UK
- Faculty of Life Sciences and Medicine, King's College London, London, UK
- National Heart and Lung Institute, Imperial College London, London, UK
| | - Judy Bradley
- Wellcome-Wolfson Institute for Experimental Medicine, Queen's University Belfast, Belfast, UK
| |
Collapse
|
13
|
Cheong I, Otero Castro V, Sosa FA, Tort Oribe B, Merlo PM, Tamagnone FM. Carotid flow as a surrogate of the left ventricular stroke volume. J Clin Monit Comput 2023; 37:661-667. [PMID: 36399216 DOI: 10.1007/s10877-022-00938-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 10/23/2022] [Indexed: 11/19/2022]
Abstract
Transthoracic echocardiography (TTE) is a fundamental tool for hemodynamic monitoring in critical patients. It allows evaluating the left ventricle's stroke volume based on the measurement of the velocity-time integral (VTI) of the left ventricle outflow tract (LVOT). However, in the intensive care unit obtaining adequate echocardiographic views may present a challenge. We propose to measure, as a surrogate of the stroke volume, the carotid flow with a novel technique. This is an observational, prospective, and simple blind study, conducted in the intensive care unit of Sanatorio de los Arcos and Hospital Aleman, in Buenos Aires, Argentina. We measured the carotid systodiastolic flow (CSD) VTI and the carotid systolic flow (CS) VTI at the level of the left supraclavicular fossa and we compared it with the LVOT VTI obtained by TTE. We evaluated 43 subjects. Spearman's correlation coefficient between LVOT VTI and CS VTI was 0.81 (95% CI 0.67-0.89) and between LVOT VTI and CSD VTI was 0.89 (95% CI 0.81-0.94). The Bland-Altman method analysis of the 5-chamber apical window LVOT VTI compared to the CSD VTI showed a bias of - 0.2 (95% CI - 0.82 to 0.43), with a concordance interval between - 4.2 (95% CI - 5.2 to - 3.1) and 3.8 cm (95% CI 2.7 to 4.9). The percentage error was 37.9%. Almost 100% of the values fell within the concordance limits, and no trend was observed in bias across the spectrum of mean variables. Although the CSD VTI could not be interchangeable with the LVOT VTI, it could be considered as its surrogate.
Collapse
Affiliation(s)
- Issac Cheong
- Department of Critical Care Medicine, Sanatorio de los Arcos, Buenos Aires, Argentina.
- Argentinian Critical Care Ultrasonography Association (ASARUC), Buenos Aires, Argentina.
| | - Victoria Otero Castro
- Department of Critical Care Medicine, Sanatorio de los Arcos, Buenos Aires, Argentina
| | - Fernando Ariel Sosa
- Argentinian Critical Care Ultrasonography Association (ASARUC), Buenos Aires, Argentina
- Department of Critical Care Medicine, Hospital Aleman, Buenos Aires, Argentina
| | - Bárbara Tort Oribe
- Department of Critical Care Medicine, Hospital Aleman, Buenos Aires, Argentina
| | - Pablo Martín Merlo
- Argentinian Critical Care Ultrasonography Association (ASARUC), Buenos Aires, Argentina
- Hospital de Agudos Bernardino Rivadavia, Buenos Aires, Argentina
| | - Francisco Marcelo Tamagnone
- Argentinian Critical Care Ultrasonography Association (ASARUC), Buenos Aires, Argentina
- Hospital Militar Campo de Mayo, Buenos Aires, Argentina
| |
Collapse
|
14
|
Murray JS, Williams CJ, Lendrem C, Smithson J, Allinson C, Robinson J, Walker A, Winter A, Simpson AJ, Newton J, Wroe C, Jones WS. Patient self-testing of kidney function at home, a prospective clinical feasibility study in kidney transplant recipients. Kidney Int Rep 2023. [DOI: 10.1016/j.ekir.2023.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023] Open
|
15
|
Madsen JM, Itenov TS, Koch EB, Bestle MH. Bioimpedance as a measure of fluids in patients with septic shock. A prospective observational study. Acta Anaesthesiol Scand 2023; 67:319-328. [PMID: 36537040 DOI: 10.1111/aas.14180] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 11/17/2022] [Accepted: 12/04/2022] [Indexed: 01/19/2023]
Abstract
BACKGROUND Septic shock is often treated with aggressive fluid resuscitation leading to profound fluid overload. The assessment of fluid status relies on suboptimal measures making treatment difficult. Bioelectrical impedance analysis is an alternative but the validity is unclear. The aim of this study was to determine the validity of bioelectrical impedance analysis for fluid measures in patients with septic shock. METHODS Single-center, prospective observational cohort study. We included adult ICU patients with septic shock. We evaluated the agreement between measures on the left and right side of the patient and measures 1 h apart by two bioelectrical impedance devices. Results are presented as Bland Altman plots with 95% Limits of Agreements (LoA) and as correlations between bioelectrical impedance analysis results and clinical markers of fluids. RESULTS Forty-nine patients were included. The agreement between measures on the left and the right side of the patient and after 1 h was overall without bias, but with wide LoA's. Fluid overload 1 h apart showed the most narrow 95% LoA (-2.4-2.9 L). The same wide limits of agreements were observed when comparing devices. For example, total body water with 95% LoA of -14.8 -16.7 L. Correlations between bioelectrical impedance analysis and clinical measures were low but statistically significant. CONCLUSIONS In patients with septic shock bioelectrical impedance analysis had no systematic errors or bias, but wide limits of agreement, indicating that the devices have a large and uncorrectable random error. Fluid status by bioelectrical impedance analysis is not sufficiently accurate to guide treatment in this group of patients.
Collapse
Affiliation(s)
- Janne Meisner Madsen
- Department of Anaesthesiology, Copenhagen University Hospital - North Zealand, Copenhagen, Denmark.,Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Theis S Itenov
- Department of Anaesthesiology, Copenhagen University Hospital - North Zealand, Copenhagen, Denmark
| | - Ellen Bjerre Koch
- Department of Anaesthesiology, Copenhagen University Hospital - North Zealand, Copenhagen, Denmark.,Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Morten H Bestle
- Department of Anaesthesiology, Copenhagen University Hospital - North Zealand, Copenhagen, Denmark.,Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
16
|
Milena Č, Romano C, De Tommasi F, Carassiti M, Formica D, Schena E, Massaroni C. Linear and Non-Linear Heart Rate Variability Indexes from Heart-Induced Mechanical Signals Recorded with a Skin-Interfaced IMU. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23031615. [PMID: 36772656 PMCID: PMC9920051 DOI: 10.3390/s23031615] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 01/02/2023] [Accepted: 01/28/2023] [Indexed: 05/26/2023]
Abstract
Heart rate variability (HRV) indexes are becoming useful in various applications, from better diagnosis and prevention of diseases to predicting stress levels. Typically, HRV indexes are retrieved from the heart's electrical activity collected with an electrocardiographic signal (ECG). Heart-induced mechanical signals recorded from the body's surface can be utilized to record the mechanical activity of the heart and, in turn, extract HRV indexes from interbeat intervals (IBIs). Among others, accelerometers and gyroscopes can be used to register IBIs from precordial accelerations and chest wall angular velocities. However, unlike electrical signals, the morphology of mechanical ones is strongly affected by body posture. In this paper, we investigated the feasibility of estimating the most common linear and non-linear HRV indexes from accelerometer and gyroscope data collected with a wearable skin-interfaced Inertial Measurement Unit (IMU) positioned at the xiphoid level. Data were collected from 21 healthy volunteers assuming two common postures (i.e., seated and lying). Results show that using the gyroscope signal in the lying posture allows accurate results in estimating IBIs, thus allowing extracting of linear and non-linear HRV parameters that are not statistically significantly different from those extracted from reference ECG.
Collapse
Affiliation(s)
- Čukić Milena
- Empa Materials Science and Technology, Biomimetic Membranes and Textiles, 9014 St. Gallen, Switzerland
- 3EGA B.V., 1062 KS Amsterdam, The Netherlands
| | - Chiara Romano
- Unit of Measurements and Biomedical Instrumentation, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy
| | - Francesca De Tommasi
- Unit of Measurements and Biomedical Instrumentation, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy
- Unit of Anesthesia, Intensive Care and Pain Management, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy
| | - Massimiliano Carassiti
- Unit of Anesthesia, Intensive Care and Pain Management, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy
| | - Domenico Formica
- School of Engineering, Newcastle University, Newcastle upon Tyne NE1 7RU, UK
| | - Emiliano Schena
- Unit of Measurements and Biomedical Instrumentation, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy
| | - Carlo Massaroni
- Unit of Measurements and Biomedical Instrumentation, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy
| |
Collapse
|
17
|
Ylikauma LA, Tuovila MJ, Ohtonen PP, Erkinaro TM, Vakkala MA, Takala HT, Liisanantti JH, Kaakinen TI. Reliability of bioreactance and pulse power analysis in measuring cardiac index during cytoreductive abdominal surgery with hyperthermic intraperitoneal chemotherapy (HIPEC). BMC Anesthesiol 2023; 23:38. [PMID: 36721097 PMCID: PMC9887811 DOI: 10.1186/s12871-023-01988-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 01/16/2023] [Indexed: 02/02/2023] Open
Abstract
PURPOSE Various malignancies with peritoneal carcinomatosis are treated with cytoreductive surgery and hyperthermic intraperitoneal chemotherapy (HIPEC). The hemodynamic instability resulting from fluid balance alterations during the procedure necessitates reliable hemodynamic monitoring. The aim of the study was to compare the accuracy, precision and trending ability of two less invasive hemodynamic monitors, bioreactance-based Starling SV and pulse power device LiDCOrapid with bolus thermodilution technique with pulmonary artery catheter in the setting of cytoreductive surgery with HIPEC. METHODS Thirty-one patients scheduled for cytoreductive surgery were recruited. Twenty-three of them proceeded to HIPEC and were included to the study. Altogether 439 and 430 intraoperative bolus thermodilution injections were compared to simultaneous cardiac index readings obtained with Starling SV and LiDCOrapid, respectively. Bland-Altman method, four-quadrant plots and error grids were used to assess the agreement of the devices. RESULTS Comparing Starling SV with bolus thermodilution, the bias was acceptable (0.13 l min- 1 m- 2, 95% CI 0.05 to 0.20), but the limits of agreement were wide (- 1.55 to 1.71 l min- 1 m- 2) and the percentage error was high (60.0%). Comparing LiDCOrapid with bolus thermodilution, the bias was acceptable (- 0.26 l min- 1 m- 2, 95% CI - 0.34 to - 0.18), but the limits of agreement were wide (- 1.99 to 1.39 l min- 1 m- 2) and the percentage error was high (57.1%). Trending ability was inadequate with both devices. CONCLUSION Starling SV and LiDCOrapid were not interchangeable with bolus thermodilution technique limiting their usefulness in the setting of cytoreductive surgery with HIPEC.
Collapse
Affiliation(s)
- Laura Anneli Ylikauma
- grid.412326.00000 0004 4685 4917Research Group of Surgery, Intensive Care Unit, Anaesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, PL 21, 90029 OYS Oulu, Finland
| | - Mari Johanna Tuovila
- grid.412326.00000 0004 4685 4917Research Group of Surgery, Intensive Care Unit, Anaesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, PL 21, 90029 OYS Oulu, Finland
| | - Pasi Petteri Ohtonen
- grid.412326.00000 0004 4685 4917Research Group of Surgery, Intensive Care Unit, Anaesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, PL 21, 90029 OYS Oulu, Finland ,grid.412326.00000 0004 4685 4917Research Service Unit, Oulu University Hospital, Oulu, Finland
| | - Tiina Maria Erkinaro
- grid.412326.00000 0004 4685 4917Research Group of Surgery, Intensive Care Unit, Anaesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, PL 21, 90029 OYS Oulu, Finland
| | - Merja Annika Vakkala
- grid.412326.00000 0004 4685 4917Research Group of Surgery, Intensive Care Unit, Anaesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, PL 21, 90029 OYS Oulu, Finland
| | - Heikki Timo Takala
- grid.412326.00000 0004 4685 4917Department of Surgery, Oulu University Hospital, Oulu, Finland
| | - Janne Henrik Liisanantti
- grid.412326.00000 0004 4685 4917Research Group of Surgery, Intensive Care Unit, Anaesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, PL 21, 90029 OYS Oulu, Finland
| | - Timo Ilari Kaakinen
- grid.412326.00000 0004 4685 4917Research Group of Surgery, Intensive Care Unit, Anaesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, PL 21, 90029 OYS Oulu, Finland
| |
Collapse
|
18
|
Ichikawa H, Yasuda E, Kumada T, Takeshima K, Ogawa S, Tsunekawa A, Goto T, Nakaya K, Akita T, Tanaka J. Intra-individual comparison of liver stiffness measurements by magnetic resonance elastography and two-dimensional shear-wave elastography in 888 patients. Ultrasonography 2023; 42:65-77. [PMID: 36366945 PMCID: PMC9816707 DOI: 10.14366/usg.22052] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 06/21/2022] [Indexed: 11/13/2022] Open
Abstract
PURPOSE Quantitative elastography methods, such as ultrasound two-dimensional shear-wave elastography (2D-SWE) and magnetic resonance elastography (MRE), are used to diagnose liver fibrosis. The present study compared liver stiffness determined by 2D-SWE and MRE within individuals and analyzed the degree of agreement between the two techniques. METHODS In total, 888 patients who underwent 2D-SWE and MRE were analyzed. Bland-Altman analysis was performed after both types of measurements were log-transformed to a normal distribution and converted to a common set of units using linear regression analysis for differing scales. The expected limit of agreement (LoA) was defined as the square root of the sum of the squares of 2D-SWE and MRE precision. The percentage difference was expressed as (2D-SWEMRE)/ mean of the two methods×100. RESULTS A Bland-Altman plot showed that the bias and upper and lower LoAs (ULoA and LLoA) were 0.0002 (95% confidence interval [CI], -0.0057 to 0.0061), 0.1747 (95% CI, 0.1646 to 0.1847), and -0.1743 (95% CI, -0.1843 to -0.1642), respectively. In terms of percentage difference, the mean, ULoA, and LLoA were -0.5944%, 19.8950%, and -21.0838%, respectively. The calculated expected LoA was 17.1178% (95% CI, 16.6353% to 17.6002%), and 789 of 888 patients (88.9%) had a percentage difference within the expected LoA. The intraclass correlation coefficient of the two methods indicated an almost perfect correlation (0.8231; 95% CI, 0.8006 to 0.8432; P<0.001). CONCLUSION Bland-Altman analysis demonstrated that 2D-SWE and MRE were interchangeable within a clinically acceptable range.
Collapse
Affiliation(s)
- Hideo Ichikawa
- Department of Medical Imaging, Graduate School of Health Science, Suzuka University of Medical Science, Suzuka, Japan
| | - Eisuke Yasuda
- Department of Medical Imaging, Graduate School of Health Science, Suzuka University of Medical Science, Suzuka, Japan,Correspondence to: Eisuke Yasuda, PhD, Department of Medical Imaging, Graduate School of Health Science, Suzuka University of Medical Science, Suzuka, Mie 510- 0293, Japan Tel. +81-059-383-8991 Fax. +81-059-383-9666 E-mail:
| | - Takashi Kumada
- Department of Nursing, Faculty of Nursing, Gifu Kyoritsu University, Ogaki, Japan
| | - Kenji Takeshima
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Japan
| | - Sadanobu Ogawa
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Japan
| | - Akikazu Tsunekawa
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Japan
| | - Tatsuya Goto
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Japan
| | - Koji Nakaya
- Department of Medical Imaging, Graduate School of Health Science, Suzuka University of Medical Science, Suzuka, Japan
| | - Tomoyuki Akita
- Department of Epidemiology, Infectious Disease Control, and Prevention, Hiroshima University Institute of Biomedical and Health Sciences, Hiroshima, Japan
| | - Junko Tanaka
- Department of Epidemiology, Infectious Disease Control, and Prevention, Hiroshima University Institute of Biomedical and Health Sciences, Hiroshima, Japan
| |
Collapse
|
19
|
Himariotis AT, Coffey KF, Noel SE, Cornell DJ. Validity of a Smartphone Application in Calculating Measures of Heart Rate Variability. SENSORS (BASEL, SWITZERLAND) 2022; 22:9883. [PMID: 36560256 PMCID: PMC9787958 DOI: 10.3390/s22249883] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 12/13/2022] [Accepted: 12/14/2022] [Indexed: 06/17/2023]
Abstract
The purpose of the current study was to determine the concurrent validity of the Elite HRV smartphone application when calculating heart rate variability (HRV) metrics in reference to an independent software criterion. A total of 5 minutes of R−R interval and natural log of root mean square of the successive differences (lnRMSSD) resting HRV data were simultaneously collected using two Polar H10 heart rate monitors (HRMs) in both the seated and supine positions from 22 participants (14 males, 8 females). One H10 HRM was paired with a Polar V800 watch and one with the Elite HRV application. When no artifact correction was applied, significant, but small, differences in the lnRMSSD data were observed between the software in the seated position (p = 0.022), and trivial and nonstatistically significant differences were observed in the supine position (p = 0.087). However, significant differences (p > 0.05) in the lnRMSSD data were no longer identifiable in either the seated or the supine positions when applying Very Low, Low, or Automatic artifact-correction filters. Additionally, excellent agreements (ICC3,1 = 0.938 − 0.998) and very strong to near-perfect (r = 0.889 − 0.997) relationships were observed throughout all correction levels. The Elite HRV smartphone application is a valid tool for calculating resting lnRMSSD HRV metrics.
Collapse
Affiliation(s)
- Andreas T. Himariotis
- Health Assessment Laboratory, University of Massachusetts Lowell, Lowell, MA 01854, USA
- Department of Physical Therapy and Kinesiology, University of Massachusetts Lowell, Lowell, MA 01854, USA
| | - Kyle F. Coffey
- Health Assessment Laboratory, University of Massachusetts Lowell, Lowell, MA 01854, USA
- Department of Physical Therapy and Kinesiology, University of Massachusetts Lowell, Lowell, MA 01854, USA
| | - Sabrina E. Noel
- Health Assessment Laboratory, University of Massachusetts Lowell, Lowell, MA 01854, USA
- Department of Biomedical and Nutritional Sciences, University of Massachusetts Lowell, Lowell, MA 01854, USA
| | - David J. Cornell
- Health Assessment Laboratory, University of Massachusetts Lowell, Lowell, MA 01854, USA
- Department of Physical Therapy and Kinesiology, University of Massachusetts Lowell, Lowell, MA 01854, USA
| |
Collapse
|
20
|
Stawschenko E, Schaller T, Kern B, Bode B, Dörries F, Kusche-Vihrog K, Gehring H, Wegerich P. Current Status of Measurement Accuracy for Total Hemoglobin Concentration in the Clinical Context. BIOSENSORS 2022; 12:1147. [PMID: 36551114 PMCID: PMC9775510 DOI: 10.3390/bios12121147] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Revised: 11/22/2022] [Accepted: 12/01/2022] [Indexed: 06/17/2023]
Abstract
OBJECTIVE The main objective of this investigation is to provide data about the accuracy of total hemoglobin concentration measurements with respect to clinical settings, and to devices within the categories of point-of-care and reference systems. In particular, tolerance of hemoglobin concentrations below 9 g/dL that have become common in clinical practice today determines the need to demonstrate the limits of measurement accuracy in patient care. METHODS Samples extracted from six units of heparinized human blood with total hemoglobin concentrations ranging from 3 to 18 g/dL were assigned to the test devices in a random order. The pool of test devices comprised blood gas analyzers, an automatic hematology analyzer, a laboratory reference method, and the point-of-care system HemoCue. To reduce the pre-analytic error, each sample was measured three times. Due to the characteristics of the tested devices and methods, we selected the mean values of the data from all these devices, measured at the corresponding total hemoglobin concentrations, as the reference. MAIN RESULTS The measurement results of the test devices overlap within strict limits (R2 = 0.999). Only the detailed analysis provides information about minor but systematic deviations. In the group of clinically relevant devices, which are involved in patient blood management decisions, the relative differences were within the limit of +/- 5 % for values down to 3 g/dL. CONCLUSIONS A clinically relevant change of +/- 0.5 g/dL of total hemoglobin concentration can be detected with all selected devices and methods. Compliance with more stringent definitions-these are the relative differences of 5 % in relation to the corresponding reference values and the clinically adapted thresholds in the format of a tolerance level analysis-was achieved by the clinical devices assessed here.
Collapse
Affiliation(s)
- Elena Stawschenko
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany
| | - Tim Schaller
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany
- Institute of Biomedical Engineering, University of Luebeck, 23562 Luebeck, Germany
| | - Benjamin Kern
- Medical Sensors and Devices Laboratory, Lübeck University of Applied Sciences, 23562 Luebeck, Germany
| | - Berit Bode
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany
| | - Frank Dörries
- Northern Scientific Tec & Integration GmbH, Kollaustr. 11-13, 22525 Hamburg, Germany
| | | | - Hartmut Gehring
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany
| | - Philipp Wegerich
- Institute of Biomedical Engineering, University of Luebeck, 23562 Luebeck, Germany
| |
Collapse
|
21
|
Assessing Agreement When Agreement Is Hard to Assess-The Agatston Score for Coronary Calcification. Diagnostics (Basel) 2022; 12:diagnostics12122993. [PMID: 36553000 PMCID: PMC9777110 DOI: 10.3390/diagnostics12122993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 11/22/2022] [Accepted: 11/28/2022] [Indexed: 12/02/2022] Open
Abstract
Method comparison studies comprised simple scatterplots of paired measurements, a 45-degree line as benchmark, and correlation coefficients up to the advent of Bland-Altman analysis in the 1980s. The Agatston score for coronary calcification is based on computed tomography of the heart, and it originated in 1990. A peculiarity of the Agatston score is the often-observed skewed distribution in screening populations. As the Agatston score has manifested itself in preventive cardiology, it is of interest to investigate how reproducibility of the Agatston score has been established. This review is based on literature findings indexed in MEDLINE/PubMed before 20 November 2021. Out of 503 identified articles, 49 papers were included in this review. Sample sizes were highly variable (10-9761), the main focus comprised intra- and interrater as well as intra- and interscanner variability assessments. Simple analysis tools such as scatterplots and correlation coefficients were successively supplemented by first difference, later Bland-Altman plots; however, only very few publications were capable of deriving Limits of Agreement that fit the observed data visually in a convincing way. Moreover, several attempts have been made in the recent past to improve the analysis and reporting of method comparison studies. These warrant increased attention in the future.
Collapse
|
22
|
Li CY, Mallinson T, Kim H, Graham J, Kuo YF, Ottenbacher KJ. Characterizing Standardized Functional Data at Inpatient Rehabilitation Facilities. J Am Med Dir Assoc 2022; 23:1845-1853.e5. [PMID: 35288084 PMCID: PMC9464264 DOI: 10.1016/j.jamda.2022.02.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 02/02/2022] [Accepted: 02/08/2022] [Indexed: 11/22/2022]
Abstract
OBJECTIVE The Improving Medicare Post-Acute Care Transformation Act of 2014 mandates using standardized patient functional data across post-acute settings. This study characterized similarities and differences in clinician-observed scores of self-care and transfer items for the standardized section GG functional domain and the functional independent measure (FIM) at inpatient rehabilitation facilities. DESIGN We conducted secondary analyses of 2017 Uniform Data System for Medical Rehabilitation national data. Patients were assessed by clinicians on both section GG and FIM at admission and discharge. We identified 7 self-care items and 6 transfer items in section GG conceptually equivalent with FIM. Clinician-assessed scores for each pair of items were examined using score distributions, Bland-Altman plot, correlation (Pearson coefficients), and agreement (kappa and weighted kappa) analyses. SETTING AND PARTICIPANTS In all, 408,491 patients were admitted to Uniform Data System for Medical Rehabilitation-affiliated inpatient rehabilitation facilities with one of the following impairments: stroke, brain dysfunction, neurologic condition, orthopedic disorders, and debility. MEASURES Section GG and FIM. RESULTS Patients were scored as more functionally independent in section GG compared with FIM, but change score distributions and score orders within impairment groups were similar. Total scores in section GG had strong positive correlations (self-care: r = 0.87 and 0.95; transfer: r = 0.82 and 0.90 at admission and discharge, respectively) with total FIM scores. Weak to moderate ranking agreements with total FIM scores were observed (self-care: kappa = 0.49 and 0.60; transfers: kappa = 0.43 and 0.52 at admission and discharge, respectively). Lower agreements were observed for less able patients at admission and for higher ability patients of their change scores. CONCLUSIONS AND IMPLICATIONS Overall, response patterns were similar in section GG and FIM across impairments. However, variations exist in score distributions and ranking agreement. Future research should examine the use of GG codes to maintain effective care, outcomes, and unbiased reimbursement across post-acute settings.
Collapse
Affiliation(s)
- Chih-Ying Li
- Department of Occupational Therapy, University of Texas Medical Branch, Galveston, TX, USA.
| | - Trudy Mallinson
- Department of Clinical Research and Leadership, The George Washington University, Washington, DC, USA
| | - Hyunkyoung Kim
- Office of Biostatistics, Department of Preventive Medicine and Public Health, University of Texas Medical Branch, Galveston, TX, USA
| | - James Graham
- Department of Occupational Therapy, Colorado State University, Fort Collins, CO, USA
| | - Yong-Fang Kuo
- Office of Biostatistics, Department of Preventive Medicine and Public Health, University of Texas Medical Branch, Galveston, TX, USA; Sealy Center on Aging, University of Texas Medical Branch, Galveston, TX, USA
| | - Kenneth J Ottenbacher
- Sealy Center on Aging, University of Texas Medical Branch, Galveston, TX, USA; Department of Nutrition, Metabolism and Rehabilitation Sciences, University of Texas Medical Branch, Galveston, TX, USA
| |
Collapse
|
23
|
Chan PY, Ryan NP, Chen D, McNeil J, Hopper I. Novel wearable and contactless heart rate, respiratory rate, and oxygen saturation monitoring devices: a systematic review and meta-analysis. Anaesthesia 2022; 77:1268-1280. [PMID: 35947876 DOI: 10.1111/anae.15834] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/08/2022] [Indexed: 11/28/2022]
Abstract
We performed a systematic review and meta-analysis to identify, classify and evaluate the body of evidence on novel wearable and contactless devices that measure heart rate, respiratory rate and oxygen saturations in the clinical setting. We included any studies of hospital inpatients, including sleep study clinics. Eighty-four studies were included in the final review. There were 56 studies of wearable devices and 29 of contactless devices. One study assessed both types of device. A high risk of patient selection and rater bias was present in proportionally more studies assessing contactless devices compared with studies assessing wearable devices (p = 0.023 and p < 0.0001, respectively). There was high but equivalent likelihood of blinding bias between the two types of studies (p = 0.076). Wearable device studies were commercially available devices validated in acute clinical settings by clinical staff and had more real-time data analysis (p = 0.04). Contactless devices were more experimental, and data were analysed post-hoc. Pooled estimates of mean (95%CI) heart rate and respiratory rate bias in wearable devices were 1.25 (-0.31-2.82) beats.min-1 (pooled 95% limits of agreement -9.36-10.08) and 0.68 (0.05-1.32) breaths.min-1 (pooled 95% limits of agreement -5.65-6.85). The pooled estimate for mean (95%CI) heart rate and respiratory rate bias in contactless devices was 2.18 (3.31-7.66) beats.min-1 (pooled limits of agreement -6.71-10.88) and 0.30 (-0.26-0.87) breaths.min-1 (pooled 95% limits of agreement -3.94-4.29). Only two studies of wearable devices measured Sp O2 ; these reported mean measurement biases of 3.54% (limits of agreement -5.65-11.45%) and 2.9% (-7.4-1.7%). Heterogeneity was observed across studies, but absent when devices were grouped by measurement modality and reference standard. We conclude that, while studies of wearable devices were of slightly better quality than contactless devices, in general all studies of novel devices were of low quality, with small (< 100) patient datasets, typically not blinded and often using inappropriate statistical techniques. Both types of devices were statistically equivalent in accuracy and precision, but wearable devices demonstrated less measurement bias and more precision at extreme vital signs. The statistical variability in precision and accuracy between studies is partially explained by differences in reference standards.
Collapse
Affiliation(s)
- P Y Chan
- Department of Intensive Care Medicine, Eastern Health, Melbourne, Vic., Australia
| | - N P Ryan
- Department of Intensive Care Medicine, Eastern Health, Melbourne, Vic., Australia
| | - D Chen
- Department of Intensive Care Medicine, Eastern Health, Melbourne, Vic., Australia
| | - J McNeil
- School of Public Health and Preventive Medicine, Monash University, Melbourne, Vic., Australia
| | - I Hopper
- School of Public Health and Preventive Medicine, Monash University, Melbourne, Vic., Australia
| |
Collapse
|
24
|
Kumada T, Ogawa S, Goto T, Toyoda H, Yasuda S, Ito T, Yasuda E, Akita T, Tanaka J. Intra-individual Comparisons of the Ultrasound-Guided Attenuation Parameter and the Magnetic Resonance Imaging-Based Proton Density Fat Fraction Using Bias and Precision Statistics. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1537-1546. [PMID: 35613974 DOI: 10.1016/j.ultrasmedbio.2022.03.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 03/25/2022] [Accepted: 03/30/2022] [Indexed: 06/15/2023]
Abstract
Ultrasound-based techniques using the attenuation coefficient, including the ultrasound-guided attenuation parameter (UGAP), have been developed for the quantification of hepatic steatosis. The magnetic resonance imaging-based proton density fat fraction (MRI-PDFF) is considered to be more accurate than liver biopsy for liver fat quantification. The aim of this study was to perform intra-individual comparisons of UGAP and MRI-PDFF for determining hepatic steatosis grade. The study enrolled 309 patients who underwent UGAP and MRI-PDFF measurements. Bland-Altman analysis was conducted after transforming MRI-PDFF values to a normal distribution and converted to a common set of units using linear regression analysis for differing scales. The expected limits of agreement (LOA) was defined as the square root of the sum of the squares of UGAP and MRI-PDFF precision. A Bland-Altman plot revealed that the bias and upper and lower LOAs (ULOA and LLOA) were -0.0047, 0.1160 and -0.1255, respectively. The percentage difference indicated that the mean, ULOA and LLOA were -1.1434%, 18.1723% and -20.4590%, respectively. The calculated expected LOA was 18.5449%, and 283 of 309 patients (91.6%) had a percentage difference within 18.5449%. Bland-Altman analysis revealed that UGAP and MRI-PDFF were interchangeable within a clinically acceptable range.
Collapse
Affiliation(s)
- Takashi Kumada
- Department of Nursing, Faculty of Nursing, Gifu Kyoritsu University, Ogaki, Gifu, Japan.
| | - Sadanobu Ogawa
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Gifu, Japan
| | - Tatsuya Goto
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Gifu, Japan
| | - Hidenori Toyoda
- Department of Gastroenterology and Hepatology, Ogaki Municipal Hospital, Ogaki, Gifu, Japan
| | - Satoshi Yasuda
- Department of Gastroenterology and Hepatology, Ogaki Municipal Hospital, Ogaki, Gifu, Japan
| | - Takanori Ito
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Eisuke Yasuda
- Department of Radiological Technology, Graduate School of Health Science, Suzuka University of Medical Science, Suzuka, Mie, Japan
| | - Tomoyuki Akita
- Department of Epidemiology, Infectious Disease Control, and Prevention, Hiroshima University Institute of Biomedical and Health Sciences, Hiroshima, Japan
| | - Junko Tanaka
- Department of Epidemiology, Infectious Disease Control, and Prevention, Hiroshima University Institute of Biomedical and Health Sciences, Hiroshima, Japan
| |
Collapse
|
25
|
Pan W, Zhang H, Jin S, Li X, Yang J, Zhang B, Dong X, Ma L, Ji W. Development and Validation of a Clinical-Image Model for Quantitatively Distinguishing Uncertain Lipid-Poor Adrenal Adenomas From Nonadenomas. Front Oncol 2022; 12:902991. [PMID: 35912200 PMCID: PMC9326106 DOI: 10.3389/fonc.2022.902991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Accepted: 06/13/2022] [Indexed: 11/13/2022] Open
Abstract
BackgroundThere remains a demand for a practical method of identifying lipid-poor adrenal lesions.PurposeTo explore the predictive value of computed tomography (CT) features combined with demographic characteristics for lipid-poor adrenal adenomas and nonadenomas.Materials and MethodsWe retrospectively recruited patients with lipid-poor adrenal lesions between January 2015 and August 2021 from two independent institutions as follows: Institution 1 for the training set and the internal validation set and Institution 2 for the external validation set. Two radiologists reviewed CT images for the three sets. We performed a least absolute shrinkage and selection operator (LASSO) algorithm to select variables; subsequently, multivariate analysis was used to develop a generalized linear model. The probability threshold of the model was set to 0.5 in the external validation set. We calculated the sensitivity, specificity, accuracy, and area under the receiver operating characteristic curve (AUC) for the model and radiologists. The model was validated and tested in the internal validation and external validation sets; moreover, the accuracy between the model and both radiologists were compared using the McNemar test in the external validation set.ResultsIn total, 253 patients (median age, 55 years [interquartile range, 47–64 years]; 135 men) with 121 lipid-poor adrenal adenomas and 132 nonadenomas were included in Institution 1, whereas another 55 patients were included in Institution 2. The multivariable analysis showed that age, male, lesion size, necrosis, unenhanced attenuation, and portal venous phase attenuation were independently associated with adrenal adenomas. The clinical-image model showed AUCs of 0.96 (95% confidence interval [CI]: 0.91, 0.98), 0.93 (95% CI: 0.84, 0.97), and 0.86 (95% CI: 0.74, 0.94) in the training set, internal validation set, and external validation set, respectively. In the external validation set, the model showed a significantly and non-significantly higher accuracy than reader 1 (84% vs. 65%, P = 0.031) and reader 2 (84% vs. 69%, P = 0.057), respectively.ConclusionsOur clinical-image model displayed good utility in differentiating lipid-poor adrenal adenomas. Further, it showed better diagnostic ability than experienced radiologists in the external validation set.
Collapse
Affiliation(s)
- Wenting Pan
- Department of Radiology, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, China
| | - Huangqi Zhang
- Department of Radiology, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, China
- *Correspondence: Huangqi Zhang, ; Wenbin Ji,
| | - Shengze Jin
- Department of Radiology, Taizhou Hospital of Zhejiang Province, Shaoxing University, Taizhou, China
| | - Xin Li
- Department of Radiology, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, China
| | - Jiawen Yang
- Department of Radiology, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, China
| | - Binhao Zhang
- Department of Radiology, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, China
| | - Xue Dong
- Department of Radiology, Taizhou Hospital, Zhejiang University, Taizhou, China
| | - Ling Ma
- He Kang Corporate Management (Shanghai) Co.Ltd, Shanghai, China
| | - Wenbin Ji
- Department of Radiology, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, China
- *Correspondence: Huangqi Zhang, ; Wenbin Ji,
| |
Collapse
|
26
|
Sravani AB, Mathew EM, Ghate V, Lewis SA. A Sensitive Spectrofluorimetric Method for Curcumin Analysis. J Fluoresc 2022; 32:1517-1527. [PMID: 35526207 PMCID: PMC9080346 DOI: 10.1007/s10895-022-02947-w] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Accepted: 04/11/2022] [Indexed: 01/07/2023]
Abstract
Curcumin (CUR), a natural polyphenolic compound extracted from the rhizomes of Curcuma longa, is used as a pharmaceutical agent, spice in food, and as a dye. Currently, CUR is being investigated for cancer treatment in Phase-II clinical trials. CUR also possesses excellent activities like anti-inflammatory, anti-microbial, and anti-oxidant, therefore quality control is crucial. The present research work was to develop a new, simple, validated and time-saving rapid 96-well plate spectrofluorimetric method for the determination of CUR. The developed method was compared with routinely used high performance liquid chromatography (HPLC) technique. The developed method were found to be linear in the concentration range of 15 to 3900 ng/mL with R2 ≥ 0.9983 for spectrofluorimetric and 50-7500 ng/mL with R2 ≥ 0.9999 for HPLC method. Accuracy, intraday and interday precision was adequate, with RSD lower than the suggested limits. The limits for the detection and the quantification of CUR were 7 and 15 ng/mL for spectrofluorimetric, and 25 and 50 ng/mL for HPLC respectively. The Bland-Altman analysis demonstrated the similarities between the two methods. The 96-well plate method was successfully applied to determine CUR in solid lipid nanoparticles (SLNs) and chitosan nanoparticles (Chi-NPs). The developed spectrofluorimetric method can hence serve as a possible replacement for the HPLC method for the quantification of CUR in healthcare and food products.
Collapse
Affiliation(s)
- Anne Boyina Sravani
- Department of Pharmaceutics, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education (MAHE), 576104, Manipal, Karnataka, India
| | - Elizabeth Mary Mathew
- School of Pharmacy, Faculty of Health Sciences, University of Botswana, Gaborone, Botswana
| | - Vivek Ghate
- Department of Pharmaceutics, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education (MAHE), 576104, Manipal, Karnataka, India
| | - Shaila A Lewis
- Department of Pharmaceutics, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education (MAHE), 576104, Manipal, Karnataka, India.
| |
Collapse
|
27
|
Fleisig GS, Slowik JS, Wassom D, Yanagita Y, Bishop J, Diffendaffer A. Comparison of marker-less and marker-based motion capture for baseball pitching kinematics. Sports Biomech 2022:1-10. [PMID: 35591756 DOI: 10.1080/14763141.2022.2076608] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Accepted: 05/06/2022] [Indexed: 10/18/2022]
Abstract
The purpose of this study was to compare baseball pitching kinematics measured with marker-less and marker-based motion capture. Two hundred and seventy-five fastball pitches were captured at 240 Hz simultaneously with a 9-camera marker-less system and a 12-camera marker system. The pitches were thrown by 30 baseball pitchers (age 17.1 ± 3.1 years). Data for each trial were time-synchronised between the two systems using the instant of ball release. Coefficients of Multiple Correlations (CMC) were computed to assess the similarity of waveforms between the two systems. Discrete measurements at foot contact, during arm cocking, and at ball release were compared between the systems using Bland-Altman plots and descriptive statistics. CMC values for the five time series analysed ranged from 0.88 to 0.97, indicating consistency in movement patterns between systems. Biases for discrete measurements ranged in magnitude from 0 to 16 degrees. Standard deviations of the differences between systems ranged from 0 to 14 degrees, while intraclass correlations ranged from 0.64 to 0.92. Thus, the marker-based and marker-less motion capture systems produced similar patterns for baseball pitching kinematics. However, based on the variations between the systems, it is recommended that a database of normative ranges be established for each system.
Collapse
Affiliation(s)
- Glenn S Fleisig
- American Sports Medicine Institute, Birmingham, AL, USA
- Dari Motion, Overland Park, KS, USA
| | | | | | - Yuki Yanagita
- American Sports Medicine Institute, Birmingham, AL, USA
| | - Jasper Bishop
- American Sports Medicine Institute, Birmingham, AL, USA
| | | |
Collapse
|
28
|
Ramos-Acevedo S, Rodríguez-Gómez L, López-Cisneros S, González-Ortiz A, Espinosa-Cuevas Á. Nutritional Status and Other Clinical Variables Are Associated to the Resting Energy Expenditure in Patients With Chronic Kidney Disease: A Validity Study. Front Nutr 2022; 9:881719. [PMID: 35662942 PMCID: PMC9161672 DOI: 10.3389/fnut.2022.881719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 04/13/2022] [Indexed: 11/30/2022] Open
Abstract
Background Estimating energy requirements (ER) is crucial for nutritional attention to chronic kidney disease (CKD) patients. Current guidelines recommend measuring ER with indirect calorimetry (IC) when possible. Due to clinical settings, the use of simple formulas is preferred. Few studies have modeled equations for estimating ER for CKD. Nevertheless, variables of interest such as nutritional status and strength have not been explored in these models. This study aimed to develop and validate a model for estimating REE in patients with CKD stages 3–5, who were not receiving renal replacement therapy (RTT), using clinical variables and comparing it with indirect calorimetry as the gold standard. Methods In this study 80 patients with CKD participated. Indirect calorimetry (IC) was performed in all patients. The calorimeter analyzed metabolic measurements every minute for 15 min after autocalibration with barometric pressure, temperature, and humidity. Bioelectrical Impedance Analysis (BIA) was performed. Fat-free mass (FFM) was registered among other bioelectrical components. Handgrip strength (HGS) was evaluated and an average of 3 repetitions was recorded. Nutritional status was assessed with the subjective global assessment (SGA). Patients categorized as B or C were then considered as having malnutrition. Results We analyzed 71 patients and 3 models were generated. Model 1a included FFM; Model 2a included weight; Model 3c included handgrip strength (HGS). All other variables were stepwise, computer-selected with a p < 0.01 significance level; Malnutrition was consistently associated with ER among other clinical variables in all models (p < 0.05). The model that included BIA-FFM had R2adjusted = 0.46, while the model that included weight (Kg) had an adjusted R2adjusted = 0.44. The models had moderate concordance, LC = 0.60–0.65 with the gold standard, whereas other energy expenditure estimation equations had LC = 0.36 and 0.55 with indirect calorimetry. Using these previously validated equations as a reference, our models had concordance values ranging from 0.66 to 0.80 with them. Conclusion Models incorporating nutritional status and other clinical variables such as weight, FFM, comorbidities, gender, and age have a moderate agreement with REE. The agreement between our models and others previously validated for the CKD patient is good; however, the agreement between the latter and IC measurements is moderate. The KDOQI lowest recommendation (25 Kcals/kg body weight) considering the 22% difference with respect to the IC for total energy expenditure rather than for REE.
Collapse
Affiliation(s)
- Samuel Ramos-Acevedo
- Department of Nephrology and Mineral Metabolism, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
- Programa de Maestría y Doctorado en Ciencias Médicas y Odontológicas y de la Salud, Universidad Nacional Autónoma de México, Mexico City, Mexico
| | - Luis Rodríguez-Gómez
- Department of Nephrology and Mineral Metabolism, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Sonia López-Cisneros
- Department of Nephrology and Mineral Metabolism, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | | | - Ángeles Espinosa-Cuevas
- Department of Nephrology and Mineral Metabolism, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
- Department of Health Care, Universidad Autónoma Metropolitana, Mexico City, Mexico
- *Correspondence: Ángeles Espinosa-Cuevas,
| |
Collapse
|
29
|
Shraim MA, Massé-Alarie H, Salomoni SE, Hodges PW. Can training of a skilled pelvic movement change corticomotor control of back muscles? Comparison of single and paired-pulse transcranial magnetic stimulation. Eur J Neurosci 2022; 56:3705-3719. [PMID: 35501123 PMCID: PMC9540878 DOI: 10.1111/ejn.15683] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 04/22/2022] [Accepted: 04/25/2022] [Indexed: 11/30/2022]
Abstract
Evidence suggests excitability of the motor cortex (M1) changes in response to motor skill learning of the upper limb. Few studies have examined immediate changes in corticospinal excitability and intra‐cortical mechanisms following motor learning in the lower back. Further, it is unknown which transcranial magnetic stimulation (TMS) paradigms are likely to reveal changes in cortical function in this region. This study aimed to (1) compare corticospinal excitability and intra‐cortical mechanisms in the lower back region of M1 before and after a single session of lumbopelvic tilt motor learning task in healthy people and (2) compare these measures between two TMS coils and two methods of recruitment curve (RC) acquisition. Twenty‐eight young participants (23.6 ± 4.6 years) completed a lumbopelvic tilting task involving three 5‐min blocks. Single‐pulse (RC from 70% to 150% of active motor threshold) and paired‐pulse TMS measures (ICF, SICF and SICI) were undertaken before (using 2 coils: figure‐of‐8 and double cone) and after (using double cone coil only) training. RCs were also acquired using a traditional and rapid method. A significant increase in corticospinal excitability was found after training as measured by RC intensities, but this was not related to the RC slope. No significant differences were found for paired‐pulse measures after training. Finally, there was good agreement between RC parameters when measured with the two different TMS coils or different acquisition methods (traditional vs. rapid). Changes in corticospinal excitability after a single session of lumbopelvic motor learning task are seen, but these changes are not explained by changes in intra‐cortical mechanisms.
Collapse
Affiliation(s)
- Muath A Shraim
- The University of Queensland, NHMRC Centre of Clinical Research Excellence in Spinal Pain, Injury & Health, School of Health & Rehabilitation Sciences, QLD, Australia
| | - Hugo Massé-Alarie
- The University of Queensland, NHMRC Centre of Clinical Research Excellence in Spinal Pain, Injury & Health, School of Health & Rehabilitation Sciences, QLD, Australia.,Centre interdisciplinaire de recherche en réadaptation et integration sociale (CIRRIS), Université Laval, Québec, QC, Canada
| | - Sauro E Salomoni
- The University of Queensland, NHMRC Centre of Clinical Research Excellence in Spinal Pain, Injury & Health, School of Health & Rehabilitation Sciences, QLD, Australia
| | - Paul W Hodges
- The University of Queensland, NHMRC Centre of Clinical Research Excellence in Spinal Pain, Injury & Health, School of Health & Rehabilitation Sciences, QLD, Australia
| |
Collapse
|
30
|
Gerke O, Pedersen AK, Debrabant B, Halekoh U, Möller S. Sample size determination in method comparison and observer variability studies. J Clin Monit Comput 2022; 36:1241-1243. [PMID: 35438365 DOI: 10.1007/s10877-022-00853-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 03/22/2022] [Indexed: 11/30/2022]
Abstract
The comparison of two quantitative measuring devices is often performed with the Limits of Agreement proposed by Bland and Altman in their seminal Lancet paper back in 1986. Sample size considerations were rare for such agreement analyses in the past, but recently several proposals have been made depending on how agreement is to be assessed and the number of replicates to be used. We have summarized recent developments and recommendations in various situations including a distinction between method comparison and observer variability studies. These include current state-of-the-art analysis of and reporting guidelines for agreement studies. General recommendations close the paper.
Collapse
Affiliation(s)
- Oke Gerke
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark. .,Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark.
| | - Andreas Kristian Pedersen
- Department of Research and Learning, Hospital of Southern Jutland, Aabenraa, Denmark.,Department of Regional Health Research, University of Southern Denmark, Odense, Denmark
| | - Birgit Debrabant
- Department of Mathematics and Computer Science, University of Southern Denmark, Odense, Denmark
| | - Ulrich Halekoh
- Epidemiology, Biostatistics and Biodemography, University of Southern Denmark, Odense, Denmark
| | - Sören Möller
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark.,Open Patient data Explorative Network, Odense University Hospital, Odense, Denmark
| |
Collapse
|
31
|
Gąsior JS, Rosoł M, Młyńczak M, Flatt AA, Hoffmann B, Baranowski R, Werner B. Reliability of Symbolic Analysis of Heart Rate Variability and Its Changes During Sympathetic Stimulation in Elite Modern Pentathlon Athletes: A Pilot Study. Front Physiol 2022; 13:829887. [PMID: 35295583 PMCID: PMC8918944 DOI: 10.3389/fphys.2022.829887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 01/21/2022] [Indexed: 11/24/2022] Open
Abstract
Background and Purpose Most studies on heart rate variability (HRV) in professional athletes concerned linear, time-, and frequency-domain indices, and there is lack of studies on non-linear parameters in this group. The study aimed to determine the inter-day reliability, and group-related and individual changes of short-term symbolic dynamics (SymDyn) measures during sympathetic nervous system activity (SNSa) stimulation among elite modern pentathletes. Methods Short-term electrocardiographic recordings were performed in stable measurement conditions with a 7-day interval between tests. SNSa stimulation via isometric handgrip strength test was conducted on the second day of study. The occurrence rate of patterns without variations (0V), with one variation (1V), two like (2LV), and two unlike variations (2UV) obtained using three approaches (the Max–min, the σ, and the Equal-probability methods) were analyzed. Relative and absolute reliability were evaluated. Results All SymDyn indices obtained using the Max–min method, 0V, and 2UV obtained using the σ method, 2UV obtained using the Equal-probability method presented acceptable inter-day reliability (the intraclass correlation coefficient between .91 and .99, Cohen’s d between −.08 and .10, the within-subject coefficient of variation between 4% and 22%). 2LV, 2UV, and 0V obtained using the Max–min and σ methods significantly decreased and increased, respectively, during SNSa stimulation—such changes were noted for all athletes. There was no significant association between differences in SymDyn parameters and respiratory rate in stable conditions and while comparing stable conditions and SNSa stimulation. Conclusion SymDyn indices may be used as reliable non-respiratory-associated parameters in laboratory settings to detect autonomic nervous system (ANS) activity modulations in elite endurance athletes. These findings provide a potential solution for addressing the confounding influence of respiration frequency on HRV-derived inferences of cardiac autonomic function. For this reason, SymDyn may prove to be preferable for field-based monitoring where measurements are unsupervised.
Collapse
Affiliation(s)
- Jakub S. Gąsior
- Department of Pediatric Cardiology and General Pediatrics, Medical University of Warsaw, Warsaw, Poland
- *Correspondence: Jakub S. Gąsior,
| | - Maciej Rosoł
- Faculty of Mechatronics, Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Warsaw, Poland
| | - Marcel Młyńczak
- Faculty of Mechatronics, Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Warsaw, Poland
| | - Andrew A. Flatt
- Biodynamics and Human Performance Center, Department of Health Sciences and Kinesiology, Georgia Southern University (Armstrong Campus), Savannah, GA, United States
| | - Bartosz Hoffmann
- Physiotherapy Division, Faculty of Medical Sciences, Medical University of Warsaw, Warsaw, Poland
| | - Rafał Baranowski
- Department of Heart Rhythm Disorders, National Institute of Cardiology, Warsaw, Poland
| | - Bożena Werner
- Department of Pediatric Cardiology and General Pediatrics, Medical University of Warsaw, Warsaw, Poland
| |
Collapse
|
32
|
Watanabe N, Otaka Y, Kumagai M, Kondo K, Shimizu E. Reliability of the Modified Nine Hole Peg Test in Healthy Adults and Individuals with Hemiparetic Stroke. Prog Rehabil Med 2022; 7:20220046. [PMID: 36160026 PMCID: PMC9470499 DOI: 10.2490/prm.20220046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Accepted: 08/16/2022] [Indexed: 11/09/2022] Open
Affiliation(s)
- Narumi Watanabe
- Department of Rehabilitation Medicine, Tokyo Bay Rehabilitation Hospital, Chiba, Japan
| | - Yohei Otaka
- Department of Rehabilitation Medicine I, School of Medicine, Fujita Health University, Aichi, Japan
| | - Masashi Kumagai
- Department of Cognitive Behavioral Physiology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Kunitsugu Kondo
- Department of Rehabilitation Medicine, Tokyo Bay Rehabilitation Hospital, Chiba, Japan
| | - Eiji Shimizu
- Department of Cognitive Behavioral Physiology, Graduate School of Medicine, Chiba University, Chiba, Japan
| |
Collapse
|
33
|
Kozlova EV, Valdez MC, Denys ME, Bishay AE, Krum JM, Rabbani KM, Carrillo V, Gonzalez GM, Lampel G, Tran JD, Vazquez BM, Anchondo LM, Uddin SA, Huffman NM, Monarrez E, Olomi DS, Chinthirla BD, Hartman RE, Kodavanti PRS, Chompre G, Phillips AL, Stapleton HM, Henkelmann B, Schramm KW, Curras-Collazo MC. Persistent autism-relevant behavioral phenotype and social neuropeptide alterations in female mice offspring induced by maternal transfer of PBDE congeners in the commercial mixture DE-71. Arch Toxicol 2022; 96:335-365. [PMID: 34687351 PMCID: PMC8536480 DOI: 10.1007/s00204-021-03163-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Accepted: 09/16/2021] [Indexed: 12/30/2022]
Abstract
Polybrominated diphenyl ethers (PBDEs) are ubiquitous persistent organic pollutants (POPs) that are known neuroendocrine disrupting chemicals with adverse neurodevelopmental effects. PBDEs may act as risk factors for autism spectrum disorders (ASD), characterized by abnormal psychosocial functioning, although direct evidence is currently lacking. Using a translational exposure model, we tested the hypothesis that maternal transfer of a commercial mixture of PBDEs, DE-71, produces ASD-relevant behavioral and neurochemical deficits in female offspring. C57Bl6/N mouse dams (F0) were exposed to DE-71 via oral administration of 0 (VEH/CON), 0.1 (L-DE-71) or 0.4 (H-DE-71) mg/kg bw/d from 3 wk prior to gestation through end of lactation. Mass spectrometry analysis indicated in utero and lactational transfer of PBDEs (in ppb) to F1 female offspring brain tissue at postnatal day (PND) 15 which was reduced by PND 110. Neurobehavioral testing of social novelty preference (SNP) and social recognition memory (SRM) revealed that adult L-DE-71 F1 offspring display deficient short- and long-term SRM, in the absence of reduced sociability, and increased repetitive behavior. These effects were concomitant with reduced olfactory discrimination of social odors. Additionally, L-DE-71 exposure also altered short-term novel object recognition memory but not anxiety or depressive-like behavior. Moreover, F1 L-DE-71 displayed downregulated mRNA transcripts for oxytocin (Oxt) in the bed nucleus of the stria terminalis (BNST) and supraoptic nucleus, and vasopressin (Avp) in the BNST and upregulated Avp1ar in BNST, and Oxtr in the paraventricular nucleus. Our work demonstrates that developmental PBDE exposure produces ASD-relevant neurochemical, olfactory processing and behavioral phenotypes that may result from early neurodevelopmental reprogramming within central social and memory networks.
Collapse
Affiliation(s)
- Elena V Kozlova
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
- Neuroscience Graduate Program, University of California, Riverside, CA, 92521, USA
| | - Matthew C Valdez
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
- Neuroscience Graduate Program, University of California, Riverside, CA, 92521, USA
- Neurological and Endocrine Toxicology Branch, Public Health and Integrated Toxicology Division, CPHEA/ORD, U.S. Environmental Protection Agency, Research Triangle Park, Durham, NC, 27711, USA
| | - Maximillian E Denys
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Anthony E Bishay
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Julia M Krum
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Kayhon M Rabbani
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Valeria Carrillo
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Gwendolyn M Gonzalez
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Gregory Lampel
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Jasmin D Tran
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Brigitte M Vazquez
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Laura M Anchondo
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Syed A Uddin
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Nicole M Huffman
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Eduardo Monarrez
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Duraan S Olomi
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Bhuvaneswari D Chinthirla
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, 92521, USA
| | - Richard E Hartman
- Department of Psychology, Loma Linda University, Loma Linda, CA, 92350, USA
| | - Prasada Rao S Kodavanti
- Neurological and Endocrine Toxicology Branch, Public Health and Integrated Toxicology Division, CPHEA/ORD, U.S. Environmental Protection Agency, Research Triangle Park, Durham, NC, 27711, USA
| | - Gladys Chompre
- Biotechnology Department, Pontifical Catholic University of Puerto Rico, Ponce, Puerto Rico, 00717-9997, USA
| | - Allison L Phillips
- Duke University, Nicholas School of the Environment, Durham, NC, 27710, USA
| | | | - Bernhard Henkelmann
- Helmholtz Zentrum Munchen, Molecular EXposomics (MEX), German National Research Center for Environmental Health (GmbH), Ingolstaedter Landstrasse 1, Neuherberg, Munich, Germany
| | - Karl-Werner Schramm
- Helmholtz Zentrum Munchen, Molecular EXposomics (MEX), German National Research Center for Environmental Health (GmbH), Ingolstaedter Landstrasse 1, Neuherberg, Munich, Germany
- Department Für Biowissenschaftliche Grundlagen, TUM, Wissenschaftszentrum Weihenstephan für Ernährung, Landnutzung Und Umwelt, Weihenstephaner Steig 23, 85350, Freising, Germany
| | | |
Collapse
|
34
|
Performance Characteristics, Intra- and Inter-Operator Agreement of Transient Elastography in Pediatric Nonalcoholic Fatty Liver Disease. J Pediatr Gastroenterol Nutr 2022; 74:e18-e19. [PMID: 34321425 DOI: 10.1097/mpg.0000000000003254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
|
35
|
Bland–Altman Limits of Agreement from a Bayesian and Frequentist Perspective. STATS 2021. [DOI: 10.3390/stats4040062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Bland–Altman agreement analysis has gained widespread application across disciplines, last but not least in health sciences, since its inception in the 1980s. Bayesian analysis has been on the rise due to increased computational power over time, and Alari, Kim, and Wand have put Bland–Altman Limits of Agreement in a Bayesian framework (Meas. Phys. Educ. Exerc. Sci. 2021, 25, 137–148). We contrasted the prediction of a single future observation and the estimation of the Limits of Agreement from the frequentist and a Bayesian perspective by analyzing interrater data of two sequentially conducted, preclinical studies. The estimation of the Limits of Agreement θ1 and θ2 has wider applicability than the prediction of single future differences. While a frequentist confidence interval represents a range of nonrejectable values for null hypothesis significance testing of H0: θ1 ≤ −δ or θ2 ≥ δ against H1: θ1 > −δ and θ2 < δ, with a predefined benchmark value δ, Bayesian analysis allows for direct interpretation of both the posterior probability of the alternative hypothesis and the likelihood of parameter values. We discuss group-sequential testing and nonparametric alternatives briefly. Frequentist simplicity does not beat Bayesian interpretability due to improved computational resources, but the elicitation and implementation of prior information demand caution. Accounting for clustered data (e.g., repeated measurements per subject) is well-established in frequentist, but not yet in Bayesian Bland–Altman analysis.
Collapse
|
36
|
Duknic M, Lichtblau M, Saxer S, Berlier C, Schneider SR, Schwarz EI, Carta AF, Furian M, Bloch KE, Ulrich S. Comparison of Repetitive Cardiac Output Measurements at Rest and End-Exercise by Direct Fick Using Pulse Oximetry vs. Blood Gases in Patients With Pulmonary Hypertension. Front Med (Lausanne) 2021; 8:776956. [PMID: 34888330 PMCID: PMC8649780 DOI: 10.3389/fmed.2021.776956] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 10/25/2021] [Indexed: 11/22/2022] Open
Abstract
Background: Exact and simultaneous measurements of mean pulmonary artery pressure (mPAP) and cardiac output (CO) are crucial to calculate pulmonary vascular resistance (PVR), which is essential to define pulmonary hypertension (PH). Simultaneous measurements of mPAP and CO are not feasible using the direct Fick (DF) method, due to the necessity to sample blood from the catheter-tip. We evaluated a modified DF method, which allows simultaneous measurement of mPAP and CO without needing repetitive blood samples. Methods: Twenty-four patients with pulmonary arterial or chronic thromboembolic PH had repetitive measurements of CO at rest and end-exercise during three phases of a crossover trial. CO was assessed by the original DF method using oxygen uptake, measured by a metabolic unit, and arterial and mixed venous oxygen saturations from co-oximetry of respective blood gases served as reference. These CO measurements were then compared with a modified DF method using pulse oximetry at the catheter- and fingertip. Results: The bias among CO measurements by the two DF methods at rest was −0.26 L/min with limits of agreement of ±1.66 L/min. The percentage error was 28.6%. At the end-exercise, the bias between methods was 0.29 L/min with limits of agreement of ±1.54 L/min and percentage error of 16.1%. Conclusion: Direct Fick using a catheter- and fingertip pulse oximetry (DFp) is a practicable and reliable method for assessing CO in patients with PH. This method has the advantage of allowing simultaneous measurement of PAP and CO, and frequent repetitive measurements are needed during exercise. Clinical Trial Registration:https://clinicaltrials.gov/ct2/show/NCT02755259, identifier: NCT02755259.
Collapse
Affiliation(s)
- Milos Duknic
- Department of Pulmonology, University Hospital Zürich, Zurich, Switzerland.,University of Zurich, Zurich, Switzerland
| | - Mona Lichtblau
- Department of Pulmonology, University Hospital Zürich, Zurich, Switzerland.,University of Zurich, Zurich, Switzerland
| | - Stéphanie Saxer
- Department of Pulmonology, University Hospital Zürich, Zurich, Switzerland.,University of Zurich, Zurich, Switzerland
| | - Charlotte Berlier
- Department of Pulmonology, University Hospital Zürich, Zurich, Switzerland.,University of Zurich, Zurich, Switzerland
| | - Simon R Schneider
- Department of Pulmonology, University Hospital Zürich, Zurich, Switzerland.,University of Zurich, Zurich, Switzerland
| | - Esther I Schwarz
- Department of Pulmonology, University Hospital Zürich, Zurich, Switzerland.,University of Zurich, Zurich, Switzerland
| | - Arcangelo F Carta
- Department of Pulmonology, University Hospital Zürich, Zurich, Switzerland.,University of Zurich, Zurich, Switzerland
| | - Michael Furian
- Department of Pulmonology, University Hospital Zürich, Zurich, Switzerland.,University of Zurich, Zurich, Switzerland
| | - Konrad E Bloch
- Department of Pulmonology, University Hospital Zürich, Zurich, Switzerland.,University of Zurich, Zurich, Switzerland
| | - Silvia Ulrich
- Department of Pulmonology, University Hospital Zürich, Zurich, Switzerland.,University of Zurich, Zurich, Switzerland
| |
Collapse
|
37
|
Ylikauma LA, Lanning KM, Erkinaro TM, Ohtonen PP, Vakkala MA, Liisanantti JH, Juvonen TS, Kaakinen TI. Reliability of Bioreactance and Pulse-Power Analysis in Measuring Cardiac Index in Patients Undergoing Cardiac Surgery With Cardiopulmonary Bypass. J Cardiothorac Vasc Anesth 2021; 36:2446-2453. [PMID: 35027295 DOI: 10.1053/j.jvca.2021.11.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 11/21/2021] [Accepted: 11/29/2021] [Indexed: 11/11/2022]
Abstract
OBJECTIVES Less-invasive and continuous cardiac output monitors recently have been developed to monitor patient hemodynamics. The aim of this study was to compare the accuracy, precision, and trending ability of noninvasive bioreactance-based Starling SV and miniinvasive pulse-power device LiDCOrapid to bolus thermodilution technique with a pulmonary artery catheter (TDCO) when measuring cardiac index in the setting of cardiac surgery with cardiopulmonary bypass (CPB). DESIGN A prospective method-comparison study. SETTING Oulu University Hospital, Finland. PARTICIPANTS Twenty patients undergoing cardiac surgery with CPB. INTERVENTIONS Cardiac index measurements were obtained simultaneously with TDCO intraoperatively and postoperatively, resulting in 498 measurements with Starling SV and 444 with LiDCOrapid. MEASUREMENTS AND MAIN RESULTS The authors used the Bland-Altman method to investigate the agreement between the devices and four-quadrant plots with error grids to assess the trending ability. The agreement between TDCO and Starling SV was qualified with a bias of 0.43 L/min/m2 (95% confidence interval [CI], 0.37-0.50), wide limits of agreement (LOA, -1.07 to 1.94 L/min/m2), and a percentage error (PE) of 66.3%. The agreement between TDCO and LiDCOrapid was qualified, with a bias of 0.22 L/min/m2 (95% CI 0.16-0.27), wide LOA (-0.93 to 1.43), and a PE of 53.2%. With both devices, trending ability was insufficient. CONCLUSION The reliability of bioreactance-based Starling SV and pulse-power analyzer LiDCOrapid was not interchangeable with TDCO, thus limiting their usefulness in cardiac surgery with CPB.
Collapse
Affiliation(s)
- Laura Anneli Ylikauma
- Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland.
| | - Katriina Marjatta Lanning
- Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland
| | - Tiina Maria Erkinaro
- Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland
| | - Pasi Petteri Ohtonen
- Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland; Division of Operative Care, Oulu University Hospital, Oulu, Finland
| | - Merja Annika Vakkala
- Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland
| | - Janne Henrik Liisanantti
- Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland
| | - Tatu Sakari Juvonen
- Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland; Department of Cardiac Surgery, Heart and Lung Center, Helsinki University Central Hospital, Helsinki University Hospital, Helsinki, Finland
| | - Timo Ilari Kaakinen
- Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland
| |
Collapse
|
38
|
Meusel M, Wegerich P, Bode B, Stawschenko E, Kusche-Vihrog K, Hellbrück H, Gehring H. Measurement of Blood Pressure by Ultrasound-The Applicability of Devices, Algorithms and a View in Local Hemodynamics. Diagnostics (Basel) 2021; 11:2255. [PMID: 34943492 PMCID: PMC8700406 DOI: 10.3390/diagnostics11122255] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 11/26/2021] [Accepted: 11/26/2021] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE Due to ongoing technical progress, the ultrasonic measurement of blood pressure (BP) as an alternative to oscillometric measurement (NIBP) or the continuous non-invasive arterial pressure method (CNAP) moves further into focus. The US method offers several advantages over NIBP and CNAP, such as deep tissue penetration and the utilization of different arterial locations. APPROACH Ten healthy subjects (six female, aged 30.9 ± 4.6 years) volunteered in our investigation. In the ultrasonic BP measurement, we differentiated between the directly measured (pulsatile diastolic and systolic vessel diameter) and indirectly calculated variables at three different artery locations on both arms, with two different ultrasound devices in the transversal and longitudinal directions of the transducer. Simultaneously, NIBP monitoring served as reference BP, while CNAP monitored the steady state condition of the arm under investigation. The Moens-Korteweg algorithm (MKE) and the algorithm of the working group of San Diego (SanD) were selected for the indirectly calculated ultrasonic BP data. MAIN RESULTS With US, we were able to measure the BP at each selected arterial position. Due to the investigation setup, we found small but significant interactions of the main effects. Bland and Altman analysis revealed that US-BP measurement was similar to NIBP, with superior accuracy when compared to the established CNAP method. In addition, US-BP measurement showed that the measurement accuracy of both arms can be regarded as identical. In a detailed comparison of the selected arterial vascular sections, systematic discrepancies between the right and left arm could be observed. CONCLUSION In our pilot study, we measured BP effectively and accurately by US using two different devices. Our findings suggest that ultrasonic BP measurement is an adequate alternative for live and continuous hemodynamic monitoring.
Collapse
Affiliation(s)
- Moritz Meusel
- Department of Cardiology, Angiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany;
| | - Philipp Wegerich
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany; (P.W.); (B.B.); (E.S.)
- Institute of Biomedical Engineering, University of Luebeck, 23562 Luebeck, Germany
| | - Berit Bode
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany; (P.W.); (B.B.); (E.S.)
| | - Elena Stawschenko
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany; (P.W.); (B.B.); (E.S.)
| | | | - Horst Hellbrück
- Department of Electrical Engineering and Computer Science, Technical University of Applied Sciences Luebeck, 23562 Luebeck, Germany;
| | - Hartmut Gehring
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany; (P.W.); (B.B.); (E.S.)
| |
Collapse
|
39
|
Ridouani F, Tuttle RM, Ghosn M, Li D, Wong RJ, Fagin JA, Monette S, Solomon SB, Camacho JC. Ultrasound-Guided Percutaneous Laser Ablation of the Thyroid Gland in a Swine Model: Comparison of Ablation Parameters and Ablation Zone Dimensions. Cardiovasc Intervent Radiol 2021; 44:1798-1806. [PMID: 34254175 PMCID: PMC9578502 DOI: 10.1007/s00270-021-02915-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 06/28/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND To compare laser ablation (LA) zone dimensions at two predetermined energy parameters to cover a theoretical 10 mm zone + 2 mm margin in a thyroid swine model. METHODS Approval of the Institutional Animal Care and Use Committee was obtained. After hydrodissection, an ultrasound-guided LA (Elesta Echolaser X4 with Orblaze technology, 1064 nm) was performed in the periphery of the thyroid in 10 swine. Two cohorts were established to ablate a region of 10mm diameter with 2mm margin based on manufacturer's ex vivo data (n= 5 at 3W/1400J and n= 5 at 3W/1800J). The ablation zone was measured on contrast-enhanced computed tomography (CT) and compared to the pathological specimen. Euthanasia was performed 48 hours following ablation. RESULTS All ablations in the 3W/1800J group achieved a diameter of 12 mm ± 1 mm in three dimensions. In the 3W/1400J group, 1 ablation reached 12 mm ± 1 mm in 2 dimensions and 4 ablations reached this size in one dimension. Maximum diameter was higher in the 3W/1800J compared to the 3W/1400J group, both on histology (1.46 cm ± 0.05 vs. 1.1 cm ± 0.0, p< 0.01) and CT (1.52 cm ± 0.04 vs. 1.18 cm ± 0.04, p< 0.01). Similar results were obtained regarding volumes, both on histology (1.12 mL ± 0.13 vs. 0.57 mL ± 0.06, p< 0.01) and CT (1.24 mL ± 0.13 vs. 0.59 mL ± 0.07, p< 0.01). Histology showed coagulation necrosis and correlated well with CT measurements. CONCLUSION Optimal parameters to obtain a LA zone of 10 mm with 2 mm margin utilizing a single needle are 3W/1800J.
Collapse
Affiliation(s)
- Fourat Ridouani
- Interventional Radiology Service, Department of Radiology, Weill-Cornell Medical College, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, Howard 118, New York 10065, T 212 639 2209, New York, NY, USA
| | - R Michael Tuttle
- Head and Neck Cancer and Endocrinology Services, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Mario Ghosn
- Interventional Radiology Service, Department of Radiology, Weill-Cornell Medical College, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, Howard 118, New York 10065, T 212 639 2209, New York, NY, USA
| | - Duan Li
- Interventional Radiology Service, Department of Radiology, Weill-Cornell Medical College, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, Howard 118, New York 10065, T 212 639 2209, New York, NY, USA
| | - Richard J Wong
- Head and Neck Cancer and Endocrinology Services, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - James A Fagin
- Head and Neck Cancer and Endocrinology Services, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Sebastien Monette
- Center of Comparative Medicine and Pathology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Stephen B Solomon
- Interventional Radiology Service, Department of Radiology, Weill-Cornell Medical College, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, Howard 118, New York 10065, T 212 639 2209, New York, NY, USA
| | - Juan C Camacho
- Interventional Radiology Service, Department of Radiology, Weill-Cornell Medical College, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, Howard 118, New York 10065, T 212 639 2209, New York, NY, USA.
| |
Collapse
|
40
|
Sirajuddin S, Sirajuddin S, Thaha R, Razak A, Ansariadi A, Taha RM, Junadi P, Ali PB. The evaluation of effect Gammarana intervention to reducing stunting during the Covid-19 pandemic: Protocol evaluation of stunting intervention in Enrekang District. J Public Health Res 2021; 11. [PMID: 34634895 PMCID: PMC8883547 DOI: 10.4081/jphr.2021.2393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Accepted: 09/24/2021] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Evaluation of large-scale stunting interventions in Indonesia has never been carried out, because it found limited sensitive and specific interventions that were carried out massively at the village level. The provincial government of South Sulawesi Indonesia in 2020 has implemented a stunting intervention model called Gammarana. The purpose of this evaluation is to analyze the impact of Gammarana on changes in stunting at the project site. Location project as many as 30 villages with a population estimated 60,000. Design and Methods: Evaluation in this study using a retrospective method and internal and external audit to document potential, then validated after the field visit Gammarana first phase in 2020. Basic Logic Model evaluation model with 22 indicators (input, process, secondary output and primary output). Proving the effect of Gammarana on changes in stunting by comparing the phenomena in the comparison village. RESULTS The comparison villages were set as equal and comparable in 13 indicators that could disturb the study conclusions. The result of the initial condition is that the conditions of the two villages of Gammarana and Villages Comparison are seen as the same in various characteristics, so that whatever the results of this evaluation study are believed to be the impact of Gammarana Project. CONCLUSIONS this protocol eligible to evaluation of Gammarana Project Intervention in Enrekang District, South Sulawesi Indonesia.
Collapse
Affiliation(s)
- Sirajuddin Sirajuddin
- Student of Doctoral Public Health Hasanuddin University, Makassar; Nutrition and Dietetic Department Health Polytechnic of Makassar.
| | - Saifuddin Sirajuddin
- Department of Nutrition, Faculty of Public Health, Hasanuddin University, Makassar.
| | - Razak Thaha
- Department of Nutrition, Faculty of Public Health, Makassar.
| | - Amran Razak
- Department of Health Administration Policy ) Faculty Public Health, Hasanuddin University,Indonesia.
| | | | - Ridwan M Taha
- Department of Nutrition, Faculty of Public Health, Makassar.
| | - Purnawan Junadi
- Department of Public Health, Faculty of Public Health, Indonesia University, Jakarta .
| | | |
Collapse
|
41
|
Friismose AI, Markovic L, Nguyen N, Gerke O, Schulz MK, Mussmann BR. Amide proton transfer-weighted MRI in the clinical setting - correlation with dynamic susceptibility contrast perfusion in the post-treatment imaging of adult glioma patients at 3T. Radiography (Lond) 2021; 28:95-101. [PMID: 34509365 DOI: 10.1016/j.radi.2021.08.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 08/13/2021] [Accepted: 08/19/2021] [Indexed: 10/20/2022]
Abstract
INTRODUCTION We investigated the correlation between amide proton transfer-weighted magnetic resonance imaging (APTw MRI) and dynamic susceptibility contrast (DSC) perfusion in order to assess the potential of APTw MRI as an alternative to DSC in adult brain tumor (glioma) imaging. METHODS After Ethical Committee approval, forty adult patients, treated for histopathologically confirmed glioma (World Health Organization (WHO) grade II-IV), were prospectively imaged at 3 Tesla (3 T) with DSC perfusion and a commercially available three-dimensional (3D) APTw sequence. Two consultant neuroradiologists independently performed region of interest (ROI) measurements on relative cerebral blood volume (rCBV) and APTw maps, co-registered with anatomical images. The correlation APTw MRI-DSC perfusion was assessed using Spearman's rank-order test. Inter-observer agreement was evaluated by the intraclass correlation coefficient (ICC) and Bland-Altman (BA) plots. RESULTS A statistically significant moderately strong positive correlation was observed between maximum rCBV (rCBVmax) and maximum APTw (APTwmax) values (observer 1: r = 0.73; p < 0.01; observer 2: r = 0.62; p < 0.01). We found good inter-observer agreement for APTwmax (ICC = 0.82; 95% confidence interval (CI) 0.66-0.90), with somewhat broad outer 95% CI for the BA Limits of Agreement (LoA) (-1.6 to 1.9). ICC for APTwmax was higher than ICC for rCBVmax (ICC = 0.74; 95%; CI 0.50-0.86), but the difference was not statistically significant. CONCLUSION APTwmax values correlate positively with rCBVmax in patients treated for brain glioma. APTw imaging is a reproducible technique, with some observer dependence. Results need to be confirmed by a larger population analysis. IMPLICATIONS FOR PRACTICE APTw MRI can be a useful addition to glioma follow-up imaging and a potential alternative to DSC perfusion, especially in patients where contrast agent is contraindicated.
Collapse
Affiliation(s)
- A I Friismose
- Radiology Department, Odense University Hospital, Odense, Denmark.
| | - L Markovic
- Radiology Department, Odense University Hospital, Odense, Denmark
| | - N Nguyen
- Radiology Department, Odense University Hospital, Odense, Denmark
| | - O Gerke
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - M K Schulz
- Department of Neurosurgery, Odense University Hospital, Odense, Denmark
| | - B R Mussmann
- Radiology Department, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark; OPEN, Odense Patient Data Exploratory Network, Odense University Hospital, Odense, Denmark; Faculty of Health Sciences, Oslo Metropolitan University, Oslo, Norway
| |
Collapse
|
42
|
Flick M, Matin Mehr J, Briesenick L, Hoppe P, Kouz K, Vokuhl C, Flotzinger D, Lerche K, Saugel B. Agreement between continuous noninvasive finger cuff-derived and invasive arterial blood pressure measurements: Effect of data sampling and data processing. Eur J Anaesthesiol 2021; 38:616-624. [PMID: 33653983 DOI: 10.1097/eja.0000000000001469] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND The effect of different methods for data sampling and data processing on the results of comparative statistical analyses in method comparison studies of continuous arterial blood pressure (AP) monitoring systems remains unknown. OBJECTIVE We sought to investigate the effect of different methods for data sampling and data processing on the results of statistical analyses in method comparison studies of continuous AP monitoring systems. DESIGN Prospective observational study. SETTING University Medical Center Hamburg-Eppendorf, Hamburg, Germany, from April to October 2019. PATIENTS 49 patients scheduled for neurosurgery with AP measurement using a radial artery catheter. MAIN OUTCOME MEASURES We assessed the agreement between continuous noninvasive finger cuff-derived (CNAP Monitor 500; CNSystems Medizintechnik, Graz, Austria) and invasive AP measurements in a prospective method comparison study in patients having neurosurgery using all beat-to-beat AP measurements (Methodall), 10-s averages (Methodavg), one 30-min period of 10-s averages (Method30), Method30 with additional offset subtraction (Method30off), and 10 30-s periods without (Methodiso) or with (Methodiso-zero) application of the zero zone. The agreement was analysed using Bland-Altman and error grid analysis. RESULTS For mean AP, the mean of the differences (95% limits of agreement) was 9.0 (-12.9 to 30.9) mmHg for Methodall, 9.2 (-12.5 to 30.9) mmHg for Methodavg, 6.5 (-9.3 to 22.2) mmHg for Method30, 0.5 (-9.5 to 10.5) mmHg for Method30off, 4.9 (-6.0 to 15.7) mmHg for Methodiso, and 3.4 (-5.9 to 12.7) mmHg for Methodiso-zero. Similar trends were found for systolic and diastolic AP. Results of error grid analysis were also influenced by using different methods for data sampling and data processing. CONCLUSION Data sampling and data processing substantially impact the results of comparative statistics in method comparison studies of continuous AP monitoring systems. Depending on the method used for data sampling and data processing, the performance of an AP test method may be considered clinically acceptable or unacceptable.
Collapse
Affiliation(s)
- Moritz Flick
- From the Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany (MF, JMM, LB, PH, KK, CV, BS), CNSystems Medizintechnik, Graz, Austria (DF, KL), and Outcomes Research Consortium, Cleveland, Ohio, USA (BS)
| | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Ylikauma LA, Ohtonen PP, Erkinaro TM, Vakkala MA, Liisanantti JH, Satta JU, Juvonen TS, Kaakinen TI. Bioreactance and fourth-generation pulse contour methods in monitoring cardiac index during off-pump coronary artery bypass surgery. J Clin Monit Comput 2021; 36:879-888. [PMID: 34037919 PMCID: PMC8150147 DOI: 10.1007/s10877-021-00721-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Accepted: 05/18/2021] [Indexed: 11/30/2022]
Abstract
The pulmonary artery catheter (PAC) is considered the gold standard for cardiac index monitoring. Recently new and less invasive methods to assess cardiac performance have been developed. The aim of our study was to assess the reliability of a non-invasive monitor utilizing bioreactance (Starling SV) and a non-calibrated mini-invasive pulse contour device (FloTrac/EV1000, fourth-generation software) compared to bolus thermodilution technique with PAC (TDCO) during off-pump coronary artery bypass surgery (OPCAB). In this prospective study, 579 simultaneous intra- and postoperative cardiac index measurements obtained with Starling SV, FloTrac/EV1000 and TDCO were compared in 20 patients undergoing OPCAB. The agreement of data was investigated by Bland-Altman plots, while trending ability was assessed by four-quadrant plots with error grids. In comparison with TDCO, Starling SV was associated with a bias of 0.13 L min-1 m-2 (95% confidence interval, 95% CI, 0.07 to 0.18), wide limits of agreement (LOA, - 1.23 to 1.51 L min-1 m-2), a percentage error (PE) of 60.7%, and poor trending ability. In comparison with TDCO, FloTrac was associated with a bias of 0.01 L min-1 m-2 (95% CI - 0.05 to 0.06), wide LOA (- 1.27 to 1.29 L min-1 m-2), a PE of 56.8% and poor trending ability. Both Starling SV and fourth-generation FloTrac showed acceptable mean bias but imprecision due to wide LOA and high PE, and poor trending ability. These findings indicate limited reliability in monitoring cardiac index in patients undergoing OPCAB.
Collapse
Affiliation(s)
- Laura Anneli Ylikauma
- Medical Research Center Oulu, Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Oulu University Hospital and University of Oulu, Oulu, Finland.
| | - Pasi Petteri Ohtonen
- Medical Research Center Oulu, Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Oulu University Hospital and University of Oulu, Oulu, Finland.,Division of Operative Care, Oulu University Hospital, Oulu, Finland
| | - Tiina Maria Erkinaro
- Medical Research Center Oulu, Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Oulu University Hospital and University of Oulu, Oulu, Finland
| | - Merja Annika Vakkala
- Medical Research Center Oulu, Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Oulu University Hospital and University of Oulu, Oulu, Finland
| | - Janne Henrik Liisanantti
- Medical Research Center Oulu, Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Oulu University Hospital and University of Oulu, Oulu, Finland
| | - Jari Uolevi Satta
- Medical Research Center Oulu, Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Oulu University Hospital and University of Oulu, Oulu, Finland
| | - Tatu Sakari Juvonen
- Medical Research Center Oulu, Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Oulu University Hospital and University of Oulu, Oulu, Finland.,Department of Cardiac Surgery, Heart and Lung Center, Helsinki University Central Hospital, Helsinki University Hospital, Helsinki, Finland
| | - Timo Ilari Kaakinen
- Medical Research Center Oulu, Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Oulu University Hospital and University of Oulu, Oulu, Finland
| |
Collapse
|
44
|
Singhal S, Gill M, Srivastava C, Gupta D, Kumar A, Kaushik A, Semwal MK. Simplifying Tumor Volume Estimation from Linear Dimensions for Intra-Cranial Lesions Treated with Stereotactic Radiosurgery. J Med Phys 2021; 45:199-205. [PMID: 33953494 PMCID: PMC8074724 DOI: 10.4103/jmp.jmp_56_20] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2020] [Revised: 12/03/2020] [Accepted: 12/03/2020] [Indexed: 11/26/2022] Open
Abstract
Aims: This study aims to derive simple yet robust formula(s) for the calculation of cranial tumor volume using linear tumor dimensions in anterioposterior (AP), mediolateral (ML) and craniocaudal (CC) directions and also propose a reproducible methodology for tumor dimension measurements. Materials and Methods: Magnetic resonance images (MRI) of 337 patients planned for Gammaknife Stereotactic Radiosurgery for different types of brain tumors were analyzed using Leksell Gamma Plan (LGP) software. Tumor volume in three dimensional was outlined and maximum tumor diameters were measured in three orthogonal directions AP, ML, and CC on the MRI. Formulas were derived to calculate tumor volume from AP, ML, and CC diameters using linear regression technique. An agreement between the calculated volume and standard volume observed from LGP software was determined using Bland Altman (B-A) plot. A comparison was made between the volume calculated using traditionally used formula of ellipsoid, standard volume obtained from LGP software and volume calculated from formulas derived in the present study. Results: The tumors were divided into two categories based on their size for better volume prediction. The tumors having product of their diameters in the range 0–2.5cc were called “small tumors” and the formula proposed for their volume estimation (V = 1.513) × (AP × ML × CC) + 0.047 ) was found to predict the tumor volume with an average bias of 0.0005cc. For “large tumors,” having product of diameters in the range 2.5–36cc, the proposed formula (V = 0.444 × (AP × ML × CC) + 0.339 ) predicted the tumor volume with an average bias of 0.007cc. Conclusions: The two formulas proposed in the study are more accurate as compared to the commonly used formula that considers the tumors as ellipsoids. The methodology proposed in the study for measurement of linear tumor dimensions is simple and reproducible.
Collapse
Affiliation(s)
- Sakshi Singhal
- Division of PET Imaging, Institute of Nuclear Medicine and Allied Sciences, Delhi, India
| | - Maneet Gill
- Department of Neurosurgery, Army Hospital Research and Referral, Delhi, India
| | - Chinmaya Srivastava
- Department of Neurosurgery, Army Hospital Research and Referral, Delhi, India
| | - Darpan Gupta
- Department of Neurosurgery, Army Hospital Research and Referral, Delhi, India
| | - Ashok Kumar
- Department of Radiation Oncology, Army Hospital Research and Referral, Delhi, India
| | - Aruna Kaushik
- Division of PET Imaging, Institute of Nuclear Medicine and Allied Sciences, Delhi, India
| | - Manoj Kumar Semwal
- Department of Radiation Oncology, Army Hospital Research and Referral, Delhi, India
| |
Collapse
|
45
|
Amado CA, Muñoz P, García-Unzueta M, Agüero J, Tello S, Fueyo P, Vega C, Lavín BA, Guerra RA, Casanova C. High parathyroid hormone predicts exacerbations in COPD patients with hypovitaminosis D. Respir Med 2021; 182:106416. [PMID: 33894440 DOI: 10.1016/j.rmed.2021.106416] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 03/09/2021] [Accepted: 04/12/2021] [Indexed: 01/29/2023]
Abstract
BACKGROUND Hypovitaminosis D has been linked to deterioration in clinical parameters and lung function in COPD. As a response to low levels of vitamin D serum Parathyroid Hormone (iPTH) is increased in some, but not all, patients. The aim of this study was to determine whether COPD patients with elevated PTH levels are at higher risk of COPD exacerbations and hospitalizations. METHODS 166 COPD outpatients were randomly preselected. Clinical and analytical characteristics were assessed at baseline. After excluding patients with other conditions known to disturb calcium metabolism 141 patients were identified. Except one, all patients were prospectively followed for 12 months after obtaining the blood samples. Hypovitaminosis D was considered when serum 25(OH)D < 30 ng/mL. Secondary hyperparathyroidism was considered when serum iPTH was higher than normal (50 pg/mL) in patients with hypovitaminosis D. COPD exacerbations and hospital admissions were recorded during the follow-up. RESULTS Prevalence of hypovitaminosis D in COPD patients was 89.3%, prevalence of secondary hyperparathyroidism associated with hypovitaminosis D was 22,9%. Cox proportional risk analysis showed that patients belonging to the high iPTH-low 25(OH)D group were at a higher risk of moderate COPD exacerbations (HR 1.81 (CI95% 1.043-3.127), p = 0.035) and hospital admissions (HR 5.45 (CI95% 2.018-14.720), p = 0.002) as compared with those with normal iPTH-low 25(OH)D levels. CONCLUSIONS COPD patients with hypovitaminosis D and elevated iPTH have higher risk of moderate exacerbations and hospitalizations than those with hypovitaminosis D and normal iPTH.
Collapse
Affiliation(s)
- Carlos A Amado
- Servicio de Neumología, Hospital Universitario Marqués de Valdecilla, Santander, Spain; Universidad de Cantabria, Santander, Spain.
| | - Pedro Muñoz
- Servicio Cántabro de Salud, Santander, Spain
| | - Mayte García-Unzueta
- Universidad de Cantabria, Santander, Spain; Servicio de Bioquímica Clínica, Hospital Universitario Marqués de Valdecilla, Spain
| | - Juan Agüero
- Servicio de Neumología, Hospital Universitario Marqués de Valdecilla, Santander, Spain
| | - Sandra Tello
- Servicio de Neumología, Hospital Universitario Marqués de Valdecilla, Santander, Spain
| | | | | | - Bernardo A Lavín
- Servicio de Bioquímica Clínica, Hospital Universitario Marqués de Valdecilla, Spain
| | - Raúl A Guerra
- Servicio de Bioquímica Clínica, Hospital Universitario Marqués de Valdecilla, Spain
| | - Ciro Casanova
- Servicio de Neumología-Unidad de Investigación, Hospital Universitario La Candelaria, Universidad de La Laguna, Tenerife, Spain
| |
Collapse
|
46
|
Simonsen C, Kristensen TS, Sundberg A, Wielsøe S, Christensen J, Hansen CP, Burgdorf SK, Suetta C, de Heer P, Svendsen LB, Achiam MP, Christensen JF. Assessment of sarcopenia in patients with upper gastrointestinal tumors: Prevalence and agreement between computed tomography and dual-energy x-ray absorptiometry. Clin Nutr 2021; 40:2809-2816. [PMID: 33933747 DOI: 10.1016/j.clnu.2021.03.022] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 02/02/2021] [Accepted: 03/16/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND & AIMS Sarcopenia is associated with an increased risk of complications to treatment and lower survival rates in patients with cancer, but there is a lack of agreement on cut-off values and assessment methods. We aimed to investigate the prevalence of sarcopenia assessed by dual-energy x-ray absorptiometry (DXA) and computed tomography (CT) as well as the agreement between the methods for identification of sarcopenia. METHODS This cross-sectional study pooled data from two studies including patients scheduled for surgery for gastrointestinal tumors. We assessed sarcopenia using two different cut-off values derived from healthy young adults for DXA and two for CT. Additionally, we used one of the most widely applied cut-off values for CT assessed sarcopenia derived from obese cancer patients. The agreement between DXA and CT was evaluated using Cohen's kappa. The mean difference and range of agreement between DXA and CT for estimating total and appendicular lean soft tissue were assessed using Bland-Altman plots. RESULTS In total, 131 patients were included. With DXA the prevalence of sarcopenia was 11.5% and 19.1%. Using CT, the prevalence of sarcopenia was 3.8% and 26.7% using cut-off values from healthy young adults and 64.1% using the widely applied cut-off value. The agreement between DXA and CT in identifying sarcopenia was poor, with Cohen's kappa values ranging from 0.05 to 0.39. The mean difference for estimated total lean soft tissue was 1.4 kg, with 95% limits of agreement from -8.6 to 11.5 kg. For appendicular lean soft tissue, the ratio between DXA and CT was 1.15, with 95% limits of agreement from 0.92 to 1.44. CONCLUSIONS The prevalence of sarcopenia defined using DXA and CT varied substantially, and the agreement between the two modalities is poor.
Collapse
Affiliation(s)
- Casper Simonsen
- Centre for Physical Activity Research (CFAS), Rigshospitalet, University of Copenhagen, Blegdamsvej 9, DK-2100 Copenhagen, Denmark.
| | - Thomas S Kristensen
- Department of Radiology, Copenhagen University Hospital, Rigshospitalet, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
| | - Anna Sundberg
- Centre for Physical Activity Research (CFAS), Rigshospitalet, University of Copenhagen, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
| | - Sabrina Wielsøe
- Centre for Physical Activity Research (CFAS), Rigshospitalet, University of Copenhagen, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
| | - Jan Christensen
- Department of Occupational Therapy and Physiotherapy, Copenhagen University Hospital, Rigshospitalet, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
| | - Carsten P Hansen
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
| | - Stefan K Burgdorf
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
| | - Charlotte Suetta
- Geriatric Research Unit, Department of Medicine, Herlev and Gentofte University Hospital, Denmark; Geriatric Research Unit, Department of Geriatric and Palliative Medicine, Bispebjerg and Frederiksberg University Hospital, Denmark
| | - Pieter de Heer
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
| | - Lars B Svendsen
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
| | - Michael P Achiam
- Department of Surgical Gastroenterology, Copenhagen University Hospital, Rigshospitalet, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
| | - Jesper F Christensen
- Centre for Physical Activity Research (CFAS), Rigshospitalet, University of Copenhagen, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
| |
Collapse
|
47
|
Jee H, Park J. Feasibility of a novice electronic psychometric assessment system for cognitively impaired. J Exerc Rehabil 2021; 16:489-495. [PMID: 33457384 PMCID: PMC7788252 DOI: 10.12965/jer.2040828.414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Accepted: 12/06/2020] [Indexed: 12/03/2022] Open
Abstract
The assessment and rehabilitation of patients with cognitive dysfunction is a field that currently requires assistive technology. While the paper-and-pencil test, such as the line tracing test, is one of the commonly used assessment methods for cognitive dysfunction, accuracy, and time-consuming assessment process needed technological application. The aim of this study was therefore to establish a computer-based real-time assessment system (e-system) for patients without compromising the usefulness of the conventional paper-and-pencil based user tools with 50 healthy participants. The comparison of the e-system with the golden-standard assessment (evaluator) results showed high concordance correlation coefficients of 0.89 and 0.87 and small effective sizes of 0.27 and 0.27 between two repeated measures. The Bland-Altman plots also showed smaller degree of error and greater repeatability in comparison to the repeated measures. Moreover, the accuracy rates of 96.5% and 96.4% were shown. The results indicated feasibility of the novice e-system. The e-system may assist rehabilitation specialists to assess and diagnose patients with cognitive dysfunction. This system can be applied to a range of assessment and rehabilitation modalities based on pen and paper. It can also be used for various patients such as those with Parkinson disease, stroke, or different forms of brain lesions.
Collapse
Affiliation(s)
- Haemi Jee
- Department of Physical Therapy, Namseoul University, Cheonan, Korea
| | - Jaehyun Park
- Department of Information and Communication, Inha University, Incheon, Korea
| |
Collapse
|
48
|
An Extension of the Bland-Altman Plot for Analyzing the Agreement of More than Two Raters. Diagnostics (Basel) 2021; 11:diagnostics11010054. [PMID: 33401454 PMCID: PMC7824071 DOI: 10.3390/diagnostics11010054] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 12/21/2020] [Accepted: 12/28/2020] [Indexed: 11/18/2022] Open
Abstract
The Bland–Altman plot is the most common method to analyze and visualize agreement between raters or methods of quantitative outcomes in health research. While very useful for studies with two raters, a limitation of the classical Bland–Altman plot is that it is specifically used for studies with two raters. We propose an extension of the Bland–Altman plot suitable for more than two raters and derive the approximate limits of agreement with 95% confidence intervals. We validated the suggested limit of agreement by a simulation study. Moreover, we offer suggestions on how to present bias, heterogeneity among raters, as well as the uncertainty of the limits of agreement. The resulting plot could be utilized to investigate and present agreement in studies with more than two raters.
Collapse
|
49
|
Heath M, Gourley D, Naghavi M, Klies S, Tanaka H. Digital thermal monitoring techniques to assess vascular reactivity following finger and brachial occlusions. J Clin Hypertens (Greenwich) 2021. [PMCID: PMC8030097 DOI: 10.1111/jch.14115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Digital thermal monitoring (DTM) is an alternative, noninvasive, methodology to evaluate endothelial function using temperature change on finger as a surrogate measure of the magnitude of vascular reactivity index (VRI). A most recent modification to the technique includes the application of occlusion cuff at the base of a finger. We evaluated the validity of DTM compared with the standard flow‐mediated dilation (FMD) protocol. Thirty‐eight (22 males; 38 ± 15 years) participants were studied. Occlusion cuff was placed over the right antecubital fossa or at the base of the right index finger. Temperature monitors were placed on bilateral index fingers to assess change in temperature throughout 5‐min occlusion and recovery phases. VRI values obtained with the finger occlusion (1.58 ± 0.29 AU) were not significantly different from VRI measured with the brachial artery occlusion (1.55 ± 0.26 AU; p = .47), and the agreement of VRI values was confirmed in the Bland‐Altman plot with a mean difference of −0.03 ± 0.34 (95% confidence interval: −0.15 to 0.09). Shear rateAUCI was significantly correlated with VRI obtained from brachial occlusion (r = .34) and finger occlusion VRI (r = .54; all p < .05). Moreover, brachial FMD was significantly correlated with brachial occlusion VRI (r = .69; p < .05) and finger occlusion VRI (r = .53; p < .05). Therefore, finger‐based VRI may be a valid and novel alternative measure of endothelial function that is more suitable than the standard FMD or hyperemic shear rate for the assessment of endothelial function in the routine clinical setting.
Collapse
Affiliation(s)
- Melanie Heath
- Cardiovascular Aging Research Laboratory Department of Kinesiology and Health Education The University of Texas at Austin Austin TX USA
| | - Drew Gourley
- Cardiovascular Aging Research Laboratory Department of Kinesiology and Health Education The University of Texas at Austin Austin TX USA
| | | | - Stanley Klies
- Department of Mechanical Engineering University of Houston Houston TX USA
| | - Hirofumi Tanaka
- Cardiovascular Aging Research Laboratory Department of Kinesiology and Health Education The University of Texas at Austin Austin TX USA
| |
Collapse
|
50
|
Gerke O. Nonparametric Limits of Agreement in Method Comparison Studies: A Simulation Study on Extreme Quantile Estimation. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17228330. [PMID: 33187125 PMCID: PMC7698333 DOI: 10.3390/ijerph17228330] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 11/06/2020] [Accepted: 11/09/2020] [Indexed: 11/16/2022]
Abstract
Bland-Altman limits of agreement and the underlying plot are a well-established means in method comparison studies on quantitative outcomes. Normally distributed paired differences, a constant bias, and variance homogeneity across the measurement range are implicit assumptions to this end. Whenever these assumptions are not fully met and cannot be remedied by an appropriate transformation of the data or the application of a regression approach, the 2.5% and 97.5% quantiles of the differences have to be estimated nonparametrically. Earlier, a simple Sample Quantile (SQ) estimator (a weighted average of the observations closest to the target quantile), the Harrell-Davis estimator (HD), and estimators of the Sfakianakis-Verginis type (SV) outperformed 10 other quantile estimators in terms of mean coverage for the next observation in a simulation study, based on sample sizes between 30 and 150. Here, we investigate the variability of the coverage probability of these three and another three promising nonparametric quantile estimators with n=50(50)200,250(250)1000. The SQ estimator outperformed the HD and SV estimators for n=50 and was slightly better for n=100, whereas the SQ, HD, and SV estimators performed identically well for n≥150. The similarity of the boxplots for the SQ estimator across both distributions and sample sizes was striking.
Collapse
Affiliation(s)
- Oke Gerke
- Department of Nuclear Medicine, Odense University Hospital, 5000 Odense C, Denmark;
- Department of Clinical Research, University of Southern Denmark, 5000 Odense C, Denmark
| |
Collapse
|