1
|
Teoli A, Ippersiel P, Bussières A, Antoniou J, Robbins SM. Understanding the impact of physical activity level and sports participation on implant integrity and failure in patients following unicompartmental and total knee arthroplasty: A scoping review. OSTEOARTHRITIS AND CARTILAGE OPEN 2024; 6:100498. [PMID: 39055118 PMCID: PMC11269905 DOI: 10.1016/j.ocarto.2024.100498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 06/24/2024] [Indexed: 07/27/2024] Open
Abstract
Objective Recommendations discouraging high levels of physical activity and sports following unicompartmental (UKA) and total knee arthroplasty (TKA) have been questioned in recent years. This scoping review aimed to summarize the literature examining the impact of physical activity level and sports participation on implant integrity and failure in patients following UKA and TKA. Methods Five databases (Medline, Embase, SCOPUS, CINAHL, ProQuest) were searched up to April 17, 2024. Retrospective, prospective and cross-sectional studies were included if they assessed the impact of physical activity level and/or sports participation (exposure variables) on implant integrity and/or failure (outcome variables) at ≥1 year following UKA or TKA. Two authors independently conducted abstract/full text reviews and data charting. Extracted data were summarized using descriptive analysis. Results Of 2014 potential records, 20 studies (UKA: n = 6 studies, 2387 patients/TKA: n = 14 studies, 7114 patients) met inclusion criteria. Following both UKA & TKA, most patients regularly participated in light to moderate physical activities and lower impact sports (e.g. walking, cycling, golf). No studies reported a deleterious effect of physical activity level or sports participation on implant integrity or failure post UKA (mean follow-up: 3.3-10.3 years). Three studies reported an association between greater levels of physical activity with increased risk of implant failure post TKA (mean follow-up: 1-11.4 years). Conclusions No studies demonstrated an association between greater levels of physical activity and sports participation with increased implant wear or failure post UKA, whereas results were mixed following TKA. There is a need for large, prospective cohort studies with long-term follow-up.
Collapse
Affiliation(s)
- Anthony Teoli
- School of Physical and Occupational Therapy, McGill University, Montreal, QC, Canada
- Lethbridge-Layton-Mackay Rehabilitation Centre, Montreal, QC, Canada
- Centre for Interdisciplinary Research in Rehabilitation, Montreal, QC, Canada
| | - Patrick Ippersiel
- School of Physical and Occupational Therapy, McGill University, Montreal, QC, Canada
- Lethbridge-Layton-Mackay Rehabilitation Centre, Montreal, QC, Canada
- Centre for Interdisciplinary Research in Rehabilitation, Montreal, QC, Canada
| | - André Bussières
- School of Physical and Occupational Therapy, McGill University, Montreal, QC, Canada
- Centre for Interdisciplinary Research in Rehabilitation, Montreal, QC, Canada
- Département Chiropratique, Université du Québec à Trois-Rivières, Trois-Rivières, QC, Canada
| | - John Antoniou
- Department of Surgery, McGill University, Montreal, QC, Canada
- Orthopaedic Research Laboratory, Lady Davis Institute, McGill University, Montreal, QC, Canada
| | - Shawn M. Robbins
- School of Physical and Occupational Therapy, McGill University, Montreal, QC, Canada
- Lethbridge-Layton-Mackay Rehabilitation Centre, Montreal, QC, Canada
- Centre for Interdisciplinary Research in Rehabilitation, Montreal, QC, Canada
| |
Collapse
|
2
|
Keane Tahmaseb GC, Keane AM, Foppiani JA, Myckatyn TM. An Update on Implant-Associated Malignancies and Their Biocompatibility. Int J Mol Sci 2024; 25:4653. [PMID: 38731871 PMCID: PMC11083590 DOI: 10.3390/ijms25094653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Revised: 04/14/2024] [Accepted: 04/22/2024] [Indexed: 05/13/2024] Open
Abstract
Implanted medical devices are widely used across various medical specialties for numerous applications, ranging from cardiovascular supports to orthopedic prostheses and cosmetic enhancements. However, recent observations have raised concerns about the potential of these implants to induce malignancies in the tissues surrounding them. There have been several case reports documenting the occurrence of cancers adjacent to these devices, prompting a closer examination of their safety. This review delves into the epidemiology, clinical presentations, pathological findings, and hypothesized mechanisms of carcinogenesis related to implanted devices. It also explores how the surgical domain and the intrinsic properties and biocompatibility of the implants might influence the development of these rare but serious malignancies. Understanding these associations is crucial for assessing the risks associated with the use of medical implants, and for developing strategies to mitigate potential adverse outcomes.
Collapse
Affiliation(s)
- Grace C. Keane Tahmaseb
- Division of Plastic and Reconstructive Surgery, Washington University School of Medicine, St. Louis, MO 63130, USA; (G.C.K.T.); (A.M.K.)
| | - Alexandra M. Keane
- Division of Plastic and Reconstructive Surgery, Washington University School of Medicine, St. Louis, MO 63130, USA; (G.C.K.T.); (A.M.K.)
| | - Jose A. Foppiani
- Division of Plastic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02215, USA;
| | - Terence M. Myckatyn
- Division of Plastic and Reconstructive Surgery, Washington University School of Medicine, St. Louis, MO 63130, USA; (G.C.K.T.); (A.M.K.)
| |
Collapse
|
3
|
Abstract
» Metallosis is a rare but significant complication that can occur after total hip arthroplasty (THA) for a variety of reasons but most commonly in patients with metal-on-metal implants.» It is characterized by the visible staining, necrosis, and fibrosis of the periprosthetic soft tissues, along with the variable presence of aseptic cysts and solid soft tissue masses called pseudotumors secondary to the corrosion and deposition of metal debris.» Metallosis can present with a spectrum of complications ranging from pain and inflammation to more severe symptoms such as osteolysis, soft tissue damage, and pseudotumor formation.» Workup of metallosis includes a clinical evaluation of the patient's symptoms, imaging studies, serum metal-ion levels, and intraoperative visualization of the staining of tissues. Inflammatory markers such as erythrocyte sedimentation rate and C-reactive protein along with intraoperative frozen slice analysis may be useful in certain cases to rule out concurrent periprosthetic joint infection.» Management depends on the severity and extent of the condition; however, revision THA is often required to prevent rapid progression of bone loss and tissue necrosis.
Collapse
Affiliation(s)
- Anderson Lee
- Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, California
| | | | | | | |
Collapse
|
4
|
Rainey JP, Gililland JM, Peters CL, Archibeck MJ, Anderson LA, Pelt CE. Metallosis and Corrosion Associated With Revision Total Knee Arthroplasties With Metaphyseal Sleeves. Arthroplast Today 2023; 22:101167. [PMID: 37521734 PMCID: PMC10372174 DOI: 10.1016/j.artd.2023.101167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2023] [Revised: 05/27/2023] [Accepted: 05/30/2023] [Indexed: 08/01/2023] Open
Abstract
Metallosis and corrosion have been associated with metal-on-metal and modular total hip arthroplasty but are rarely described in the setting of primary or revision total knee arthroplasty (TKA). In this series, we report on cases of metallosis due to mechanically assisted crevice corrosion at modular junctions of machined trunnion-bore tapers in a revision TKA system with metaphyseal sleeves. The unique design of metal modular junctions used in sleeve-based revision TKA, along with potential patient and surgical factors, may predispose these designs to fretting, corrosion, and adverse reaction to metal debris. We now consider metallosis and corrosion in the workup of painful or failed revision TKAs with sleeves. Future studies that investigate the incidence of this phenomenon may be warranted.
Collapse
Affiliation(s)
| | | | | | | | | | - Christopher E. Pelt
- Corresponding author. 590 Wakara Way, Salt Lake City, UT 84108, USA. Tel.: +1 801 703 4046.
| |
Collapse
|
5
|
Khandelwal G, Roychoudhury A, Bhutia O, Shariff A. Longitudinal surveillance of serum titanium ion levels in patients with indigenous 3D printed total temporomandibular joint replacement. Sci Rep 2023; 13:7275. [PMID: 37142652 PMCID: PMC10160034 DOI: 10.1038/s41598-023-33229-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Accepted: 04/10/2023] [Indexed: 05/06/2023] Open
Abstract
The purpose of this longitudinal study was to surveil the serum titanium ion levels at various time intervals in patients with indigenous 3D-printed total temporomandibular joint replacement (TMJ TJR). The study was conducted on 11 patients (male: 8; female: 3) who had undergone unilateral or bilateral TMJ TJR. Blood samples were drawn preoperatively (T0), 3 months (T1), 6 months (T2), and 1 year (T3) postoperatively. Data were analyzed and a p value of < 0.05 was considered statistically significant. The mean serum titanium ion levels at T0, T1, T2, and T3 was 9.34 ± 8.70 µg/L (mcg/L), 35.97 ± 20.27 mcg/L, 31.68 ± 17.03 mcg/L, and 47.91 ± 15.47 mcg/L respectively. The mean serum titanium ion levels increased significantly at T1 (p = 0.009), T2 (p = 0.032), and T3 (p = 0.00) interval. There was no significant difference between unilateral and bilateral groups. Serum titanium ion continued to show increased levels till the last follow-up of 1 year. These initial serum titanium ion levels increase is due to the initial wear phase of the prosthesis which manifests over 1 year. Further studies with large sample sizes and long-term follow-ups are required to see the deleterious effect if any on the TMJ TJR.
Collapse
Affiliation(s)
- Garima Khandelwal
- Department of Oral and Maxillofacial Surgery, All India Institute of Medical Sciences, New Delhi, 110029, India
| | - Ajoy Roychoudhury
- Department of Oral and Maxillofacial Surgery, All India Institute of Medical Sciences, New Delhi, 110029, India.
| | - Ongkila Bhutia
- Department of Oral and Maxillofacial Surgery, All India Institute of Medical Sciences, New Delhi, 110029, India
| | - A Shariff
- Department of Anatomy, All India Institute of Medical Sciences, New Delhi, 110029, India
| |
Collapse
|
6
|
Yuen JC, Pang HN, Woo YL, Lo NN, Keng Jin DT, Chia SL, Yeo SL. Long-Term Outcomes of Articular Surface Replacement (ASR) Implant in Hip Arthroplasty: A Single Institution Review. Cureus 2023; 15:e36029. [PMID: 36915400 PMCID: PMC10008120 DOI: 10.7759/cureus.36029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/11/2023] [Indexed: 03/13/2023] Open
Abstract
Various metal-on-metal (MoM) total hip replacements (THRs) have been found to have high short-term failure rates due to adverse responses to metal debris (ARMD). As a consequence, several low-performing THRs have been removed off the market. The purpose of this research was to look at the at least five-year outcomes of patients who had MoM hip arthroplasty at our institution. In one specialised centre between 2007 and 2008, 24 Articular Surface Replacement (ASRTM, DePuy, Warsaw, IN, USA) MoM THRs (in 24 patients, mean age: 56.4 years) were implanted. DePuy ASR hip prosthesis for osteoarthritis or hip fractures were employed in the THR system. All patients were summoned back for a clinical assessment, and imaging was done as needed. The average period of follow-up was 8.0 years (6.0-10 years). In all, eight instances (33.3%) were discovered to have pseudotumors, four hips (16.7%) were revised, and one (4.1%) was operated for ARMD. The Western Ontario and McMaster Universities Arthritis Index (WOMAC) and Oxford ratings improved statistically significantly five years after surgery in all three areas of pain, disability, and stiffness; however, there was no statistically significant change in the 36-Item Short Form Survey (SF-36) (mental) score. MoM hip arthroplasty had a greater revision incidence at five years in our group, presumably owing to the adoption of a smaller femoral head size.
Collapse
Affiliation(s)
- Jin Chuan Yuen
- Department of Orthopaedics, Hospital Tengku Ampuan Afzan, Kuantan, MYS
| | - Hee Nee Pang
- Orthopedics, Singapore General Hospital, Singapore, SGP
| | - Yew Lok Woo
- Orthopedics and Traumatology, Singapore General Hospital, Singapore, SGP
| | - Ngai Nung Lo
- Orthopedics, Singapore General Hospital, Singapore, SGP
| | | | - Shi Lu Chia
- Orthopedics and Traumatology, Singapore General Hospital, Singapore, SGP
| | - Seng Lin Yeo
- Orthopedic Surgery, Singapore General Hospital, Singapore, SGP
| |
Collapse
|
7
|
Banci L, Balato G, Salari P, Baldini A. "Systematic review and meta-analysis of ceramic coated implants in total knee arthroplasty. Comparable mid-term results to uncoated implants.". Knee Surg Sports Traumatol Arthrosc 2023; 31:839-851. [PMID: 34714355 DOI: 10.1007/s00167-021-06775-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Accepted: 10/08/2021] [Indexed: 11/09/2022]
Abstract
BACKGROUND Nitride-based ceramic coatings, such as titanium nitride (TiN) and titanium niobium nitride (TiNbN), have been introduced in total knee arthroplasty (TKA) to enhance the mechanical properties and biocompatibility of knee components, harden the metal surface and reduce CoCrMo exposure and metal ion release. However, the theoretical advantages of these ceramic coatings in TKA have yet to be fully elucidated. This systematic review aimed to provide clinical evidence on mid-term outcomes of ceramic-coated knee prostheses in comparison with uncoated standard CoCrMo knee prostheses in primary TKA. The hypothesis was that ceramic-coated implants can be used in primary TKA with no inferior outcomes compared to uncoated CoCrMo implants. METHODS A systematic review of the literature was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines to find all clinical studies regarding primary TKA with ceramic-coated knee prostheses. MEDLINE (PubMed), Embase and Cochrane Library were searched from 1990 to October 2020 to identify relevant studies for the first qualitative analysis. Using PICOS eligibility criteria, a subgroup of the selected studies was used to perform a meta-analysis. RESULTS Fifteen studies were included in this systematic review, of which six were included in the meta-analysis: 3 randomized controlled trials, 2 retrospective comparative studies and 1 prospective cross-sectional study. Pooled data overall included 321 coated TKAs vs. 359 uncoated TKAs and a mean follow-up of 4.6 years (range, 2-10 years). No significant difference in the implant survival risk ratio with revision or reoperation due to any reason was found between coated and uncoated TKAs, even considering the RCT study subgroup with a risk ratio of 1.02 (P = 0.34). No significant differences were found for postoperative complications, clinical scores, or metal blood concentrations at 1 year. CONCLUSION The findings of this systematic review and meta-analysis support the statement that ceramic-coated TKAs are not inferior to uncoated TKAs, showing comparable survival rates, complication rates and clinical outcomes. There is strong evidence that ceramic-coated TKA does not improve the clinical results or survival rate in comparison with uncoated TKA. LEVEL OF EVIDENCE II, Therapeutic.
Collapse
Affiliation(s)
- Lorenzo Banci
- Permedica Orthopaedics S.P.A, Via Como 38, Merate, 23807, Lecco, Italy.
| | - Giovanni Balato
- Department of Public Health, Section of Orthopaedic Surgery, "Federico II" University, Naples, Italy
| | | | | |
Collapse
|
8
|
Deroche E, Batailler C, Shatrov J, Gunst S, Servien E, Lustig S. No clinical difference at mid-term follow-up between TiN-coated versus uncoated cemented mobile-bearing total knee arthroplasty: a matched cohort study. SICOT J 2023; 9:5. [PMID: 36757220 PMCID: PMC9910165 DOI: 10.1051/sicotj/2023001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 01/05/2023] [Indexed: 02/10/2023] Open
Abstract
INTRODUCTION Nitride-based ceramic coating was introduced into surgical implants to improve hardness, reduce abrasion, and decrease the risk of metal-induced adverse reactions, especially for patients with suspected or identified metal hypersensitivity. The study aimed to evaluate the effectiveness and safety of a titanium nitride (TiN) coated prosthesis with a mobile bearing design. METHODS This was a retrospective matched-cohort study from a single center, comparing clinical outcomes between patients receiving either a TiN-coated versus an uncoated cobalt-chromium-molybdenum (CoCrMo) prostheses for primary total knee replacement. Seventeen patients received the TiN prosthesis between 2015 and 2019. These were matched 1:2 with patients receiving uncoated mobile-bearing knee prostheses with the same design manufacturer. RESULTS Fourteen patients in the TiN group had complete 5-year follow-up data and were compared with 34 patients from the CoCrMo group. The Knee Society Score was 170.6 ± 28.0 (Function subscore 83.7 ± 17.5 and Knee subscore 86.9 ± 13.8) in the TiN group and 180.7 ± 49.4 (Function subscore 87.5 ± 14.3 and Knee subscore 93.2 ± 9.6) in CoCrMo group, with no statistically significant difference (p = 0.19). One patient underwent a revision for instability requiring the removal of the implant in the TiN group and none in the CoCrMo group. The survival rates were 92.9% (CI95% 77.3-100.0) and 100.0% in the TiN group and CoCrMo group respectively (p = 1.0). DISCUSSION TiN-coated TKA with mobile bearing resulted in satisfactory clinical outcomes, and a low revision rate, and there was no complication related to the coated implant. The use of TiN-coated prostheses in case of confirmed or suspected metal allergy provides satisfactory short-term clinic outcomes.
Collapse
Affiliation(s)
- Etienne Deroche
- Orthopaedic Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital 69004 Lyon France,Corresponding author:
| | - Cécile Batailler
- Orthopaedic Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital 69004 Lyon France
| | - Jobe Shatrov
- Sydney Orthopaedic Research Institute (SORI) at Landmark Orthopaedics 500 Pacific Hwy St. Leonards NSW Australia
| | - Stanislas Gunst
- Orthopaedic Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital 69004 Lyon France
| | - Elvire Servien
- Orthopaedic Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital 69004 Lyon France,LIBM – EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University 69622 Lyon France
| | - Sébastien Lustig
- Orthopaedic Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital 69004 Lyon France,University of Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406 69622 Lyon France
| |
Collapse
|
9
|
Thienpont E. Titanium niobium nitride knee implants are not inferior to chrome cobalt components for primary total knee arthroplasty at medium-term follow-up. Arch Orthop Trauma Surg 2023:10.1007/s00402-022-04754-1. [PMID: 36595031 DOI: 10.1007/s00402-022-04754-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Accepted: 12/28/2022] [Indexed: 01/04/2023]
Abstract
BACKGROUND Oxidized zirconium (Oxinium), titanium nitride (TiN) or titanium niobium nitride (TiNbN) coated implants became in recent years available for an increasing amount of total knee arthroplasty (TKA) systems. The hypothesis of this study was that the use of TiNbN-coated components would not lead to inferior results compared to conventional implants and that none of the metal hypersensitivity patients receiving TiNbN-coated implants would require revision for metal allergy. MATERIALS AND METHODS This retrospective study compared 53 Titanium Niobium Nitride coated TKA with 103 conventional chrome cobalt implants of the same design. Patients were evaluated at a minimal follow-up of 3 years. RESULTS No differences in clinical, radiological or patient-reported outcome measurements were observed between these groups. A survivorship of 96% without differences in revision rates was observed at medium-term follow-up of 6.5 years. DISCUSSION Metal allergy leading to contact or generalized dermatitis after TKA is very rare and usually linked to chrome or cobalt hypersensitivity. Nickel release from knee implants has not been shown to lead to cutaneous symptoms, but unexplained pain and swelling, peri-prosthetic osteolysis and component loosening remain potential issues not fully understood. The use of coated implants eliminates this factor from the diagnostic equation in case of postoperative dissatisfaction. CONCLUSION The use of titanium niobium nitride coated implants for primary knee osteoarthritis in self-reported metal hypersensitivity patients shows similar outcomes and survivorship rates as conventional chrome cobalt TKA, with no revisions for allergy at medium-term follow-up.
Collapse
Affiliation(s)
- Emmanuel Thienpont
- Cliniques Universitaires Saint Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium.
| |
Collapse
|
10
|
Wu D, Bhalekar RM, Marsh JS, Langton DJ, Stewart AJ. Periarticular metal hypersensitivity complications of hip bearings containing cobalt-chromium. EFORT Open Rev 2022; 7:758-771. [PMID: 36475551 PMCID: PMC9780614 DOI: 10.1530/eor-22-0036] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Hip joints with bearings composed of cobalt-chromium alloy (metal-on-metal bearings) have been one of the most widely used implants in joint replacement arthroplasty. Unfortunately, these implants can contribute to a complication called aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL), a type IV metal hypersensitivity response around the joint. Consistent with such bearings, increased metal debris can be found in the surrounding fluids and in remote tissues and organs, due to wear and corrosion. It is hypothesized that metal ions released from the prosthesis (including Co2+) can potentially form haptens with proteins such as serum albumin in synovial fluid that in turn elicit ALVAL. Generally, elevated cobalt and chromium levels in synovial fluids may indicate implant failure. However, such measurements cannot be used as a reliable tool to predict the onset of ALVAL. To detect ALVAL, some diagnostic tests, questionnaires and imaging techniques have been used clinically with some success, but a standardized approach is lacking. At present, guidelines for implant usage and patient management are ambiguous and inconsistent across health care authorities. To reduce and better manage the development of ALVAL, further research into the precise molecular mechanism(s) by which ALVAL develops is urgently needed. Identification of diagnostic and prognostic biomarkers for ALVAL is required, as are more standardized guidelines for surgery and patient management.
Collapse
Affiliation(s)
- Dongmei Wu
- School of Medicine, University of St. Andrews, St. Andrews, Fife, United Kingdom
| | - Rohan M Bhalekar
- ExplantLab, The Biosphere, Newcastle Helix, Newcastle-upon-Tyne, United Kingdom
| | - Jordan S Marsh
- School of Medicine, University of St. Andrews, St. Andrews, Fife, United Kingdom
| | - David J Langton
- ExplantLab, The Biosphere, Newcastle Helix, Newcastle-upon-Tyne, United Kingdom
| | - Alan J Stewart
- School of Medicine, University of St. Andrews, St. Andrews, Fife, United Kingdom,Correspondence should be addressed to A J Stewart;
| |
Collapse
|
11
|
Langton DJ, Bhalekar RM, Joyce TJ, Rushton SP, Wainwright BJ, Nargol ME, Shyam N, Lie BA, Pabbruwe MB, Stewart AJ, Waller S, Natu S, Ren R, Hornick R, Darlay R, Su EP, Nargol AVF. The influence of HLA genotype on the development of metal hypersensitivity following joint replacement. COMMUNICATIONS MEDICINE 2022; 2:73. [PMID: 35761834 PMCID: PMC9232575 DOI: 10.1038/s43856-022-00137-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 06/07/2022] [Indexed: 12/27/2022] Open
Abstract
Background Over five million joint replacements are performed across the world each year. Cobalt chrome (CoCr) components are used in most of these procedures. Some patients develop delayed-type hypersensitivity (DTH) responses to CoCr implants, resulting in tissue damage and revision surgery. DTH is unpredictable and genetic links have yet to be definitively established. Methods At a single site, we carried out an initial investigation to identify HLA alleles associated with development of DTH following metal-on-metal hip arthroplasty. We then recruited patients from other centres to train and validate an algorithm incorporating patient age, gender, HLA genotype, and blood metal concentrations to predict the development of DTH. Accuracy of the modelling was assessed using performance metrics including time-dependent receiver operator curves. Results Using next-generation sequencing, here we determine the HLA genotypes of 606 patients. 176 of these patients had experienced failure of their prostheses; the remaining 430 remain asymptomatic at a mean follow up of twelve years. We demonstrate that the development of DTH is associated with patient age, gender, the magnitude of metal exposure, and the presence of certain HLA class II alleles. We show that the predictive algorithm developed from this investigation performs to an accuracy suitable for clinical use, with weighted mean survival probability errors of 1.8% and 3.1% for pre-operative and post-operative models respectively. Conclusions The development of DTH following joint replacement appears to be determined by the interaction between implant wear and a patient's genotype. The algorithm described in this paper may improve implant selection and help direct patient surveillance following surgery. Further consideration should be given towards understanding patient-specific responses to different biomaterials.
Collapse
Affiliation(s)
- David J. Langton
- ExplantLab, The Biosphere, Newcastle Helix, Newcastle-upon-Tyne, England
| | - Rohan M. Bhalekar
- ExplantLab, The Biosphere, Newcastle Helix, Newcastle-upon-Tyne, England
| | | | | | | | - Matthew E. Nargol
- ExplantLab, The Biosphere, Newcastle Helix, Newcastle-upon-Tyne, England
| | - Nish Shyam
- ExplantLab, The Biosphere, Newcastle Helix, Newcastle-upon-Tyne, England
| | - Benedicte A. Lie
- Department of Medical Genetics, University of Oslo and Oslo University Hospital, Oslo, Norway
| | | | - Alan J. Stewart
- School of Medicine, University of St Andrews, St Andrews, Scotland
| | - Susan Waller
- University Hospital of North Tees, Stockton, England
| | - Shonali Natu
- University Hospital of North Tees, Stockton, England
| | - Renee Ren
- Hospital for Special Surgery, New York, USA
| | | | | | | | | |
Collapse
|
12
|
Gramlich Y, Hofmann L, Kress S, Ruckes C, Kemmerer M, Klug A, Hoffmann R, Kremer M. Critically high metal ion levels found in metal-on-metal modular hinged knee arthroplasty : a comparison of two different systems. Bone Joint J 2022; 104-B:376-385. [PMID: 35227095 DOI: 10.1302/0301-620x.104b3.bjj-2021-0492.r2] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
AIMS This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant. METHODS A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life. RESULTS No differences in mean age (69 years, 40 to 86), mean age adapted Charlson Comorbidity Index (3.1 (SD 1.4)), mean BMI (29.2 kg/m2 (SD 5.8)), or number of other implants were observed between groups. Significant improvements in outcome scores and pain levels were achieved for all groups, and there was no difference in quality of life (12-Item Short-Form Health Survey questionnaire (SF-12)). Mean cobalt and chromium ion levels were significantly higher for the GenuX versus the BPKS hinged TKA (GenuX vs BPKS: cobalt: 16.3 vs 9.4 µg/l; chromium: 9.5 vs 5.2 µg/l). The TiN-coated implants did not appear to confer improvement in the metal ion levels. Metal ion concentrations above 7 µg/l were detected in 81%(29/36) of GenuX patients versus 41% (11/27) in the BPKS group. No GenuX patients had normal levels under 2 µg/l, versus 22% of BPKS patients. No significant reduction in outcome scores was observed regardless of the metal ion levels, whereas higher work-related activity was correlated with higher chromium concentrations. CONCLUSION Hinged TKA, using MoM hinges, resulted in critically high cobalt and chromium ion concentrations. The BPKS hinged TKA showed significantly lower metal ion concentrations compared with the GenuX TKA. No benefits were observed using TiN coating. The different weightbearing mechanics might influence the wear of the component materials. Higher workloads and physical activity could influence chromium levels. Cite this article: Bone Joint J 2022;104-B(3):376-385.
Collapse
Affiliation(s)
- Yves Gramlich
- Department of Trauma and Orthopedic Surgery, Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Frankfurt, Germany
| | - Line Hofmann
- Department of Trauma and Orthopedic Surgery, Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Frankfurt, Germany
| | - Sandra Kress
- Department of Trauma and Orthopedic Surgery, Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Frankfurt, Germany
| | - Christian Ruckes
- Interdisciplinary Center for Clinical Studies, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Matthias Kemmerer
- Department of Trauma and Orthopedic Surgery, Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Frankfurt, Germany
| | - Alexander Klug
- Department of Trauma and Orthopedic Surgery, Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Frankfurt, Germany
| | - Reinhard Hoffmann
- Department of Trauma and Orthopedic Surgery, Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Frankfurt, Germany
| | - Michael Kremer
- Department of Trauma and Orthopedic Surgery, Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Frankfurt, Germany
| |
Collapse
|
13
|
Postler A, Beyer F, Lützner C, Tille E, Lützner J. [The use of knee prostheses with a hypoallergenic coating is safe in the medium term : A randomized controlled study]. DER ORTHOPADE 2021; 51:660-668. [PMID: 34734297 PMCID: PMC9352637 DOI: 10.1007/s00132-021-04186-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Accepted: 10/11/2021] [Indexed: 10/25/2022]
Abstract
BACKGROUND In Germany, patients with contact allergy to implant components usually receive coated joint arthroplasties. Whether the treatment using these hypoallergenic implants achieves comparable results to standard treatment with implants consisting of cobalt-chromium alloy (CoCr) implants is controversially discussed internationally and has rarely been investigated in the mid-term. OBJECTIVES Are there differences in blood metal ion concentrations, knee function, and patient-reported outcomes (PROM) between coated and standard implants? MATERIAL AND METHODS 118 patients were randomized to receive either a coated or a standard implant. Knee function as well as patient-reported outcome measures were assessed. Metal ion concentrations in blood samples were additionally determined for chromium, cobalt, molybdenum, and nickel, preoperatively, one and five years after surgery. RESULTS After five years, it was possible to analyse the results of 97 patients. In metal ion concentrations, as well as PRO, consistently good results were seen, without any difference between the groups. While in 13 patients there was an increase in chromium concentration above 2 µg/l one year after surgery, there was no measured value above 1 µg/l after five years. CONCLUSION In our study, similar mid-term results were detected for coated (TiNiN) and standard (CoCr)TKA. With respect to metal ion concentrations and PRO there are no disadvantages in using coated TKA.
Collapse
Affiliation(s)
- Anne Postler
- UniversitätsCentrum für Orthopädie, Unfall- und Plastische Chirurgie, Universitätsklinikum Carl Gustav Carus Dresden, TU Dresden, Fetscherstraße 74, 01307, Dresden, Deutschland.
| | - Franziska Beyer
- UniversitätsCentrum für Orthopädie, Unfall- und Plastische Chirurgie, Universitätsklinikum Carl Gustav Carus Dresden, TU Dresden, Fetscherstraße 74, 01307, Dresden, Deutschland
| | - Cornelia Lützner
- UniversitätsCentrum für Orthopädie, Unfall- und Plastische Chirurgie, Universitätsklinikum Carl Gustav Carus Dresden, TU Dresden, Fetscherstraße 74, 01307, Dresden, Deutschland
| | - Eric Tille
- UniversitätsCentrum für Orthopädie, Unfall- und Plastische Chirurgie, Universitätsklinikum Carl Gustav Carus Dresden, TU Dresden, Fetscherstraße 74, 01307, Dresden, Deutschland
| | - Jörg Lützner
- UniversitätsCentrum für Orthopädie, Unfall- und Plastische Chirurgie, Universitätsklinikum Carl Gustav Carus Dresden, TU Dresden, Fetscherstraße 74, 01307, Dresden, Deutschland
| |
Collapse
|
14
|
Kenny F, Gibbons JP, Keogh P, O'Byrne J. Revision of total knee replacement (TKR) secondary to raised cobalt levels: should this be considered in the painful TKR patient? BMJ Case Rep 2021; 14:14/7/e240674. [PMID: 34266815 DOI: 10.1136/bcr-2020-240674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
A 63-year-old woman was referred to the specialised knee revision clinic with ongoing knee pain after total knee replacement. She incidentally had cobalt and chromium levels measured. These were seen to be elevated. Comprehensive assessment and investigation did not identify any other source of cobalt or chromium. Aseptic loosening of the knee was diagnosed, and the knee was revised. At the time of surgery, the tissue was seen to be darkened consistent with metallosis. Multiple samples excluded infection on extended cultures. Aspirated fluid showed that periprosthetic fluid had elevated cobalt levels. The knee was successfully revised with good symptomatic outcome and significantly, over the course of several months post-revision, the cobalt and chromium levels returned to normal.
Collapse
Affiliation(s)
- Fred Kenny
- School of Medicine, University of Limerick, Castletroy, Limerick, Ireland
| | - John P Gibbons
- Orthopaedic Department, Cappagh National Orthopaedic Hospital, Dublin, Ireland
| | - Peter Keogh
- Orthopaedic Department, Cappagh National Orthopaedic Hospital, Dublin, Ireland
| | - John O'Byrne
- Orthopaedic Department, Cappagh National Orthopaedic Hospital, Dublin, Ireland
| |
Collapse
|
15
|
Roy ME, Whiteside LA, Ly KK, Gauvain MJ. Cobalt-chromium femoral components developed scratches and released metal debris in simulated wear whereas ceramic femoral components did not. Bone Joint J 2021; 103-B:94-101. [PMID: 34053284 DOI: 10.1302/0301-620x.103b6.bjj-2020-2429.r1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
AIMS The aims of this study were to evaluate wear on the surface of cobalt-chromium (CoCr) femoral components used in total knee arthroplasty (TKA) and compare the wear of these components with that of ceramic femoral components. METHODS Optical profilometry was used to evaluate surface roughness and to examine the features created by the wear process in a knee wear simulator. We developed a method of measuring surface changes on five CoCr femoral components and quantifying the loss of material from the articular surface during the wear process. We also examined the articular surface of three ceramic femoral components from a previous test for evidence of surface damage, and compared it with that of CoCr components. RESULTS We found that the surface roughness of CoCr components rapidly increased during the first 1,000 wear cycles, then reached a steady state, but material loss from the surface continued at a rate of 1,778,000 μm3 per million cycles as carbides were removed from its matrix. These carbides formed third-body wear particles, leading to the formation of new scratches even as older scratches were worn away. In contrast, no scratching, loss of material, or other surface damage, when evaluated with one nanometer resolution, was found on the surface of the ceramic components after a 15 M wear cycle test. CONCLUSION This study showed wear and loss of CoCr material from scratching and microabrasive wear in TKA. The material loss from the surface continued in a linear relationship with increasing cycles. We also found the absence of scratching and roughening of ceramic femoral components in simulated wear, suggesting an advantage in wear rate and avoiding metal sensitivity. This may have implications in the management of persistent pain after TKA. Cite this article: Bone Joint J 2021;103-B(6 Supple A):94-101.
Collapse
Affiliation(s)
- Marie E Roy
- Missouri Bone & Joint Research Foundation, St Louis, Missouri, USA
| | - Leo A Whiteside
- Missouri Bone & Joint Research Foundation, St Louis, Missouri, USA
| | - Kevin K Ly
- Missouri Bone & Joint Research Foundation, St Louis, Missouri, USA
| | | |
Collapse
|
16
|
Bellova P, Pablik J, Stiehler M, Dragu A, Lützner J. Large Soft-tissue Mass Formation After Revision Total Knee Arthroplasty: An Unusual Case of Adverse Reaction to Metal Debris and Review of the Literature. Arthroplast Today 2021; 9:122-128. [PMID: 34189217 PMCID: PMC8220300 DOI: 10.1016/j.artd.2021.05.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 05/01/2021] [Accepted: 05/03/2021] [Indexed: 11/10/2022] Open
Abstract
We report about the rare case of a patient who developed large soft-tissue mass formations related with revision total knee arthroplasty which was implanted 4 years prior. Owing to suspected periprosthetic joint infection, the prosthesis was removed and the lesions were resected, resulting in severe soft-tissue loss and temporary arthrodesis using a poly(methyl methacrylate) spacer. Histological analysis revealed a type VI periprosthetic membrane. The situation was further complicated by wound infection requiring multiple revision surgeries. After discussion and evaluation of the available treatment options, the decision for an above-the-knee amputation was made. The tissue reaction resulting in these soft-tissue lesions is referred to as an "adverse local tissue reaction." Wear-induced lesions after total knee arthroplasty, especially of this magnitude, are very rare and difficult to treat.
Collapse
Affiliation(s)
- Petri Bellova
- Department of Orthopedics Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technische Universität (TU) Dresden, Dresden, Germany
| | - Jessica Pablik
- Department of Pathology, University Hospital Carl Gustav Carus, Technische Universität Dresden (TU), Dresden, Germany
| | - Maik Stiehler
- Department of Orthopedics Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technische Universität (TU) Dresden, Dresden, Germany
| | - Adrian Dragu
- Department of Orthopedics Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technische Universität (TU) Dresden, Dresden, Germany
| | - Jörg Lützner
- Department of Orthopedics Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technische Universität (TU) Dresden, Dresden, Germany
| |
Collapse
|
17
|
BLOOD CHROMIUM-COBALT LEVELS IN PATIENTS AFTER TOTAL KNEE ARTHROPLASTY AND THEIR EFFECT ON THE RETINAL NERVE FIBER LAYER AND MACULAR GANGLION CELL COMPLEX. Retina 2021; 40:1200-1206. [PMID: 31021899 DOI: 10.1097/iae.0000000000002535] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
PURPOSE To study blood cobalt (Co) and chromium (Cr) levels in patients who have undergone total knee arthroplasty and their effect on the retinal nerve fiber layer and macular ganglion cell complex. METHODS One hundred patients who had undergone total knee arthroplasty and 50 healthy individuals who had no implants were included in the study. The patients were separated into two groups based on how long ago the prosthesis had been implanted (Group 1: 1 to 5 years; Group 2: 5 to 10 years). After a complete ophthalmological examination, retinal nerve fiber layer and macular ganglion cell complex of the patients were evaluated with optical coherence tomography, performed on dilated pupils. To assess the metal ion levels of the patients, venous blood samples were drawn from each patient. RESULTS The mean age of the patients was 64.72 ± 6.26 years in Group 1, 67.80 ± 8.07 years in Group 2, and 63.42 ± 7.90 years in the control group. In the comparison of age and sex, there were no statistically significant differences between the groups and the control group. Co and Cr levels were statistically higher in Group 1 and Group 2 compared with the control group (P < 0.001). Mean retinal nerve fiber layer thicknesses and mean macular ganglion cell complex thicknesses in Group 1 and Group 2 were statistically lower than in the control group. CONCLUSION Levels of Co and Cr are higher in patients who undergone total knee arthroplasty than healthy subjects, and these higher levels were associated with changes in the retinal nerve fiber layer and macular ganglion cell complex.
Collapse
|
18
|
Bormann T, Jäger S, Kretzer JP, Nebel L, Clarius L, Omlor G, Bitsch R, Lehner B. Retrieval Analysis of Modern Knee Tumor Megaendoprosthesis Shows Considerable Volumetric Metal Wear Generated at the Rotating Hinge. MATERIALS 2020; 13:ma13071519. [PMID: 32224971 PMCID: PMC7178100 DOI: 10.3390/ma13071519] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 03/23/2020] [Accepted: 03/25/2020] [Indexed: 12/20/2022]
Abstract
Frequently occurring damage, as well as elevated blood metal ion levels, are reported in relation to a tumor and revision system for total knee arthroplasty (TKA), which applies a rotating hinge coupling with a metal-on-metal (MoM) articulation. As the patient collective for this specific system is small, there is no data on wear generated from the couplings. In this study, wear volume and influencing parameters were investigated at 44 retrieved TKAs with MoM couplings. A scoring system rating frequently occurring abrasive wear between 0 (no wear) and 3 (distinct wear) was established. The wear score was correlated to time in vivo, bone resection length, patient weight and polyethylene inlay damage. Volumetric wear was estimated applying coordinate measurements. An elevated wear score of two or higher was found in 43% of cases. The mean wear rate accounted to 7.8 mm3/year. The main influencing coefficient for the extent of wear is time in vivo. We found a tendency for higher wear scores with higher inlay degradation scores. Patient weight and bone resection length did not impact coupling wear. Assessment of wear damage by a semi-quantitative scoring system has proven to be a reliable option for non-destructive coupling evaluation. The generated wear volume is high.
Collapse
Affiliation(s)
- Therese Bormann
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany; (S.J.); (J.P.K.); (L.N.); (L.C.)
- Correspondence:
| | - Sebastian Jäger
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany; (S.J.); (J.P.K.); (L.N.); (L.C.)
| | - J. Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany; (S.J.); (J.P.K.); (L.N.); (L.C.)
| | - Laura Nebel
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany; (S.J.); (J.P.K.); (L.N.); (L.C.)
| | - Lucas Clarius
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany; (S.J.); (J.P.K.); (L.N.); (L.C.)
| | - Georg Omlor
- Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany; (G.O.); (B.L.)
| | - Rudi Bitsch
- ATOS Clinic Heidelberg, 69115 Heidelberg, Germany;
| | - Burkhard Lehner
- Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany; (G.O.); (B.L.)
| |
Collapse
|
19
|
Reiner T, Sorbi R, Müller M, Nees T, Kretzer JP, Rickert M, Moradi B. Blood Metal Ion Release After Primary Total Knee Arthroplasty: A Prospective Study. Orthop Surg 2020; 12:396-403. [PMID: 32023362 PMCID: PMC7189061 DOI: 10.1111/os.12591] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 10/30/2019] [Accepted: 11/18/2019] [Indexed: 12/14/2022] Open
Abstract
Objectives To investigate the course of in vivo blood metal ion levels in patients undergoing primary total knee arthroplasty (TKA) and to investigate potential risk factors associated with metal ion release in these patients. Methods Twenty‐five patients with indication for TKA were included in this prospective study. Whole blood metal ion analysis was performed pre‐operatively and at 1 week, 6 weeks, 3 months, 6 months, and 12 months postoperatively. Clinical scores were obtained using the American Knee Society Score (AKSS) and the Oxford Knee Score (OKS) at each follow‐up and patientsʼ activity levels were assessed by measuring the mean annual walking cycles at 12 months follow‐up. Anteroposterior and lateral radiographs of the operated knee were evaluated postoperatively and at 12‐month follow‐up with regard to implant position and radiological signs of implant loosening. Correlation analysis using multivariate linear regression was performed to investigate the influence of different variables (age, gender, functional scores, number of walking cycles, and body mass index [BMI]) on blood cobalt ion concentrations. Results Mean metal ion levels of cobalt, chromium, molybdenum, and titanium were 0.28 μg/L (SD, 0.14), 0.43 μg/L (SD, 0.49), 0.62 μg/L (SD, 0.45), and 1.96 μg/L (SD, 0.98), respectively at 12‐month follow‐up. Mean cobalt ion levels significantly increased 1‐year after surgery compared to preoperative measurements. There was no statistically significant increase of mean metal ion levels of chromium, titanium, and molybdenum at 1‐year follow‐up. Overall, metal ion levels were low and no patient demonstrated cobalt ion levels above 1 μg/L. Postoperative radiographs demonstrated well‐aligned TKAs in all patients and no signs of osteolysis or implant loosening were detected at 1‐year follow‐up. Both the AKSS and OKS significantly improved during the course of the study up to the final follow‐up. Multivariate regression analysis did not show a statistically significant correlation between the tested variables and blood cobalt ion concentrations. Conclusion A statistically significant increase of mean cobalt ion concentration at 1‐year follow‐up was found in this cohort of patients with well‐functioning TKA, although overall blood metal ion levels were relatively low. Despite low systemic metal ion concentrations seen in this cohort, the local effects of increased metal ion concentrations in the periprosthetic environment on the long‐term outcome of TKA should be further investigated.
Collapse
Affiliation(s)
- Tobias Reiner
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Reza Sorbi
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Maike Müller
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Timo Nees
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Jan Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Markus Rickert
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Giessen, Germany
| | - Babak Moradi
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| |
Collapse
|
20
|
Is There Material Loss at the Conical Junctions of Modular Components for Total Knee Arthroplasty? J Arthroplasty 2019; 34:2479-2486. [PMID: 31227303 DOI: 10.1016/j.arth.2019.05.030] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Revised: 05/01/2019] [Accepted: 05/20/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Clinical concern exists regarding fretting corrosion and material loss from taper junctions in orthopedic devices, with previous research focusing on the modular components from total hip arthroplasty. Comparatively little has been published regarding the fretting corrosion and material loss in modular knee devices. The purpose of this study is to evaluate fretting corrosion damage and quantify material loss for conical total knee arthroplasty taper interfaces. METHODS Stem tapers of 166 retrieved modular knee devices were evaluated for fretting corrosion using a semiquantitative scoring method. High precision profilometry was then used to determine volumetric material loss and maximum wear depth for a subset of 37 components (implanted for 0.25-18.76 years). Scanning electron microscopy and energy-dispersive X-ray spectroscopy were used to characterize the observed damage. RESULTS Mild to severe fretting corrosion was observed on the majority of tapers, with 23% receiving a maximum visually determined damage score of 4. The median rate of volumetric material loss was 0.11 mm3/y (range 0.00-0.76) for femoral components (both cone and bore taper surfaces combined) and 0.01 mm3 (range 0.00-8.10) for tibial components. Greater rates of material loss were associated with mixed metal pairings. There was a strong correlation between visual fretting corrosion score and calculated material loss (ρ = 0.68, P < .001). Scanning electron microscopy revealed varying degrees of scratching, wear, fretting corrosion, and instances of cracking with morphology not consistent with fretting corrosion, wear, or fatigue. CONCLUSION Although visual evidence of fretting corrosion damage was prevalent and correlated with taper material loss, the measured volumetric material loss was low compared with prior reports from total hip arthroplasty.
Collapse
|
21
|
Vendittoli PA, Massé V, Kiss MO, Lusignan D, Lavigne M. Modular junction may be more problematic than bearing wear in metal-on-metal total hip arthroplasty. Hip Int 2019; 29:262-269. [PMID: 30378457 DOI: 10.1177/1120700018808696] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION In total hip arthroplasty (THA), local adverse reaction to metal debris (ARMD) may be caused by abnormal metal ion release from a metal-on-metal (MoM) bearing, or by wear and corrosion of the implant's modular junction. The aim of this study was to compare ion levels and rate of ARMD between patients sharing the same MoM bearing but 1 group having monoblock stems versus another having modular stems. MATERIALS AND METHODS Whole blood cobalt (Co) and chromium (Cr) ion concentrations, ARMD rate, revision rate, and function measured by UCLA and WOMAC scores were compared between groups. RESULTS ARMD rate was significantly higher in the modular group (46%) compared with the monoblock group (16%, p = 0.031). Revision for ARMD was performed at 52.8 ± 8.1 months in the modular group versus 98.2 ± 15.5 months after primary THA in the monoblock group. ARMD originated from wear and corrosion of the junction between stem and femoral head adapter sleeve in all monoblock cases, and the junction between stem and modular neck in all the modular ones. Cr and Co ions levels were significantly higher in the modular stem group ( p < 0.001 for both). CONCLUSIONS Although both groups had MoM bearings, corrosion at stem/neck or neck/head junctions combining dissimilar metal (Ti and Cr-Co) was seen as the source of excess metal ions release leading to ARMD. Poor performance of the modular junction may be more deleterious than wear of the bearing. To avoid such complications, THA femoral stem modular junctions should be eliminated (return to a full monoblock implant) or have improved junction design.
Collapse
Affiliation(s)
- Pascal-André Vendittoli
- Department of Surgery, University of Montreal, Hospital Maisonneuve-Rosemont, Montreal, Canada
| | - Vincent Massé
- Department of Surgery, University of Montreal, Hospital Maisonneuve-Rosemont, Montreal, Canada
| | - Marc-Olivier Kiss
- Department of Surgery, University of Montreal, Hospital Maisonneuve-Rosemont, Montreal, Canada
| | - Daniel Lusignan
- Department of Surgery, University of Montreal, Hospital Maisonneuve-Rosemont, Montreal, Canada
| | - Martin Lavigne
- Department of Surgery, University of Montreal, Hospital Maisonneuve-Rosemont, Montreal, Canada
| |
Collapse
|
22
|
Reiner T, Bader N, Panzram B, Bülhoff M, Omlor G, Kretzer JP, Raiss P, Zeifang F. In vivo blood metal ion levels in patients after total shoulder arthroplasty. J Shoulder Elbow Surg 2019; 28:539-546. [PMID: 30518478 DOI: 10.1016/j.jse.2018.08.027] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Revised: 08/17/2018] [Accepted: 08/19/2018] [Indexed: 02/01/2023]
Abstract
BACKGROUND Products from metal wear have been identified as a potential cause of adverse local tissue reactions and implant failure in total hip arthroplasty. However, the role of metal ion exposure in patients after total shoulder replacement is unclear. The objective of the present study was to determine in vivo blood metal ion levels of cobalt, chromium, and titanium in patients after anatomic total shoulder arthroplasty (TSA) or reverse TSA. METHODS A consecutive series of patients after anatomic TSA or reverse TSA was evaluated retrospectively. After exclusion of patients with additional metal implants, 40 patients with unilateral anatomic TSA (n = 20) or reverse TSA (n = 20) were available for whole-blood metal ion analysis at a mean follow-up of 28 ± 9.6 months. Twenty-three healthy individuals without metal implants served as a control group. RESULTS Mean cobalt ion concentrations were 0.18 µg/L (range, 0.1-0.66 µg/L), 0.15 µg/L (range, 0.03-0.48 µg/L), and 0.11 µg/L (range, 0.03-0.19 µg/L), mean chromium ion levels were 0.48 µg/L (range, 0.17-2.41 µg/L), 0.31 µg/L (range, 0.09-1.26 µg/L), and 0.14 µg/L (range, 0.04-0.99 µg/L), and mean titanium ion concentrations were 1.31 µg/L (range, 0.75-4.52 µg/L), 0.84 µg/L (range, 0.1-1.64 µg/L), and 0.62 µg/L (range, 0.32-2.14 µg/L) in the reverse TSA group, the anatomic TSA group, and the control group, respectively. CONCLUSIONS TSA resulted in elevated metal ion levels compared with healthy controls, although overall metal ion concentrations measured in this study were relatively low. The role of local metal ion exposure in patients with total shoulder replacements should be further investigated.
Collapse
Affiliation(s)
- Tobias Reiner
- Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany.
| | - Nina Bader
- Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Benjamin Panzram
- Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Matthias Bülhoff
- Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Georg Omlor
- Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Jan P Kretzer
- Laboratory of Biomechanics and Implant Research, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Patric Raiss
- OCM (Orthopädische Chirurgie München) Clinic for Orthopedic Surgery, Munich, Germany
| | - Felix Zeifang
- Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| |
Collapse
|
23
|
Postler A, Beyer F, Lützner C, Tille E, Lützner J. Similar outcome during short-term follow-up after coated and uncoated total knee arthroplasty: a randomized controlled study. Knee Surg Sports Traumatol Arthrosc 2018; 26:3459-3467. [PMID: 29616285 DOI: 10.1007/s00167-018-4928-0] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Accepted: 03/28/2018] [Indexed: 12/27/2022]
Abstract
PURPOSE Patients with known hypersensitivity to metals often require hypoallergenic TKA implants. Coating of a standard implant is a common solution, and although in vitro tests have demonstrated reduction of polyethylene wear for these coatings, it is still unknown whether these implants have any clinical benefit. This study was initiated to investigate metal ion concentrations, knee function and patient-reported outcome (PRO) after coated and uncoated TKA. METHODS One hundred and twenty-two (122) patients were randomized to receive a coated or a standard TKA and, after exclusions, 59 patients were included in each group. Knee function and PRO were assessed with validated scores up to 3 years after surgery. Metal ion concentrations in blood samples were determined for chromium, cobalt, molybdenum and nickel, preoperatively and 1 year after surgery. RESULTS Chromium concentrations in patient plasma increased from a median of 0.25 to 1.30 µg/l in the standard TKA group, and from 0.25 to 0.75 µg/l in the coated TKA group (p = 0.012). Thirteen patients (3 coated, 10 standard TKA) had chromium concentrations above 2 µg/l. The concentrations of cobalt, molybdenum and nickel did not change. Patient-reported outcome measures (PROM) demonstrated a substantial improvement after TKA, without any differences between the groups. CONCLUSION The increase in chromium concentration in the standard group needs further investigation. If surgeons use coated implants, they can be confident that these implants perform as well as standard implants. LEVEL OF EVIDENCE I.
Collapse
Affiliation(s)
- Anne Postler
- University Center of Orthopaedics and Traumatology, University Medicine Carl Gustav Carus Dresden, Fetscherstr. 74, 01307, Dresden, Germany
| | - Franziska Beyer
- University Center of Orthopaedics and Traumatology, University Medicine Carl Gustav Carus Dresden, Fetscherstr. 74, 01307, Dresden, Germany
| | - Cornelia Lützner
- University Center of Orthopaedics and Traumatology, University Medicine Carl Gustav Carus Dresden, Fetscherstr. 74, 01307, Dresden, Germany
| | - Eric Tille
- University Center of Orthopaedics and Traumatology, University Medicine Carl Gustav Carus Dresden, Fetscherstr. 74, 01307, Dresden, Germany
| | - Jörg Lützner
- University Center of Orthopaedics and Traumatology, University Medicine Carl Gustav Carus Dresden, Fetscherstr. 74, 01307, Dresden, Germany.
| |
Collapse
|
24
|
Arnholt CM, MacDonald DW, Klein GR, Cates HE, Rimnac CM, Kurtz SM, Kocagoz S, Chen AF. What Is the Incidence of Cobalt-Chromium Damage Modes on the Bearing Surface of Contemporary Femoral Component Designs for Total Knee Arthroplasty? J Arthroplasty 2018; 33:3313-3319. [PMID: 29871834 PMCID: PMC6146069 DOI: 10.1016/j.arth.2018.05.020] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2018] [Revised: 04/25/2018] [Accepted: 05/10/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study was to determine the incidence of metal release in contemporary total knee arthroplasty and the patient-related factors associated with this release. METHODS In total, 256 retrieved cobalt-chromium femoral components were collected through a multi-institutional orthopedic implant retrieval program (implanted: 1-15 years). Implants were mainly revised for loosening (84/256), instability (62/256), and infection (46/256). Third-body damage was assessed using a semiquantitative scoring method. Microscale electro-corrosion damage (MECD) was evaluated using digital optical microscopy. Radii of curvature were measured from representative components to calculate anterior-posterior and medial-lateral ratios. Femoral component surface roughness was measured using a white light interferometer. Using a multivariable linear model, associations between damage score, implant, and patient factors were tested. Spearman's ρ correlation tests were performed to determine the association between roughness measurements and damage score. RESULTS Mild to severe damage was observed in 52% (134/256) of the components. In the multivariable linear model, anterior-posterior ratio (β = -8.07; P < .001), loosening (β = -0.52; P = .006), and patient weight (β = 0.01; P = .007) were associated with damage score. Suspected MECD damage was observed in 82% (209/256) of components. The Ra value (ρ = 0.196; P = .002) and Rq value (ρ = 0.157; P = .012) increased as the damage score increased. CONCLUSION The findings of this retrieval study support that similar damage mechanisms exist in contemporary and long-term total knee arthroplasty devices. Additionally, we observed associations between loosening, anterior-posterior conformity, and patient weight with increased surface damage.
Collapse
Affiliation(s)
- Christina M. Arnholt
- Implant Research Center, Drexel University, 3401 Market Street, Suite 345, Philadelphia, PA 19104
| | - Daniel W. MacDonald
- Implant Research Center, Drexel University, 3401 Market Street, Suite 345, Philadelphia, PA 19104
| | - Gregg R. Klein
- Hartzband Center for Hip & Knee Replacement, Paramus, NJ
| | | | - Clare M. Rimnac
- Department of Mechanical and Aerospace Engineering and the Center for the Evaluation of Implant Performance, Case Western Reserve University, 10900 Euclid Ave., Cleveland, Ohio 44106
| | - Steven M. Kurtz
- Implant Research Center, Drexel University, 3401 Market Street, Suite 345, Philadelphia, PA 19104,Exponent, Inc., 3440 Market Street, Suite 600, Philadelphia, PA 19104
| | | | - Sevi Kocagoz
- Implant Research Center, Drexel University, 3401 Market Street, Suite 345, Philadelphia, PA 19104
| | - Antonia F. Chen
- Brigham and Women’s Hospital, Department of Orthopaedics, Harvard Medical School, Boston, MA 02115
| |
Collapse
|
25
|
Puente Reyna AL, Fritz B, Schwiesau J, Schilling C, Summer B, Thomas P, Grupp TM. Metal ion release barrier function and biotribological evaluation of a zirconium nitride multilayer coated knee implant under highly demanding activities wear simulation. J Biomech 2018; 79:88-96. [DOI: 10.1016/j.jbiomech.2018.07.043] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 07/20/2018] [Accepted: 07/31/2018] [Indexed: 12/13/2022]
|
26
|
Hunt LP, Blom AW, Matharu GS, Porter ML, Whitehouse MR. The risk of developing cancer following metal-on-metal hip replacement compared with non metal-on-metal hip bearings: Findings from a prospective national registry "The National Joint Registry of England, Wales, Northern Ireland and the Isle of Man". PLoS One 2018; 13:e0204356. [PMID: 30235326 PMCID: PMC6147563 DOI: 10.1371/journal.pone.0204356] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2018] [Accepted: 09/06/2018] [Indexed: 12/13/2022] Open
Abstract
Background and purpose Over 1 million metal-on-metal hip replacements were implanted. Even well-functioning implants produce wear debris that can cause tissue damage, disseminate and cause DNA damage. We aimed to establish if there was an association between metal-on-metal hip replacement and the risk of subsequently developing cancer compared with alternative hip replacements. Methods We performed a population based prospective longitudinal cohort study using data from the National Joint Registry linked to Hospital Episode Statistics (n = 403,881 patients). We examined the incidence of a new diagnosis of cancer in patients who received a metal-on-metal bearing in comparison with those who received a non metal-on-metal bearing. Kaplan-Meier estimates of time to first cancer diagnosis were used with Cox proportional hazards regression models to assess the effect on the time to cancer diagnosis for all cancer types, haematological, malignant melanoma, urinary tract cancers or prostate cancer in men. Results The maximum follow up available was 11.8 years with 25% of patients followed up for more than 6.8 years (mean follow up 4.6 years; median 4.3; IQR 2.1–6.8; range 0.01–11.8). Analyses by gender that adjusted for age at primary and presence or absence of linked Welsh (PEDW) records showed no increase in the risk of developing cancer according to the bearing surface implanted for all cancers, haematological cancers, malignant melanoma, urinary tract cancers or prostate cancer in men. For patients receiving a second hip replacement, there was also no difference. Conclusion We have demonstrated that there is currently no evidence of an increase in the risk of cancer following primary hip replacement according to the type of bearing material used. Although the risk of revision in metal-on-metal bearing hip replacements is higher, it is reassuring that the risk of a new diagnosis of cancer is not currently increased. Despite the long term follow up available in this study, the latency period for some cancers is very long and therefore continued monitoring is required to ensure no new patterns emerge that may indicate need for universal screening.
Collapse
Affiliation(s)
- Linda P. Hunt
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol & Southmead Hospital, Bristol, United Kingdom
| | - Ashley W. Blom
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol & Southmead Hospital, Bristol, United Kingdom
- National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol, Bristol, United Kingdom
| | - Gulraj S. Matharu
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol & Southmead Hospital, Bristol, United Kingdom
| | - Martyn L. Porter
- Centre for Hip Surgery, Wrightington Hospital, Wrightington, Lancashire, United Kingdom
- * E-mail: (MRW); (MLP)
| | - Michael R. Whitehouse
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol & Southmead Hospital, Bristol, United Kingdom
- National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol, Bristol, United Kingdom
- * E-mail: (MRW); (MLP)
| |
Collapse
|
27
|
Lionberger DR, Samorajski J, Wilson CD, Rivera A. What role does metal allergy sensitization play in total knee arthroplasty revision? J Exp Orthop 2018; 5:30. [PMID: 30109436 PMCID: PMC6091498 DOI: 10.1186/s40634-018-0146-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Accepted: 07/26/2018] [Indexed: 02/08/2023] Open
Abstract
Background Clinicians are often faced with the decision whether to revise a painful total knee replacement in patients who have chronic vague pain with no apparent explanation. A sensitive metal testing assay called the lymphocyte stimulation test has been used to detect nickel sensitization in patients with orthopedic implants. We hypothesize that nickel sensitization plays a role in the pathology of failed joint arthroplasty in patients with unexplained dissatisfaction. Methods 32 patients with symptomatic total knee arthroplasty without obvious mechanical findings were tested prior to revision surgery. 19 nickel-sensitized and 13 non-sensitized patients were compared by cell counts of synovium surgical specimens for CD4+ and CD8+ cell lines. Patients were then revised with ceramic-coated implants. Secondary evaluation of functional outcomes, range of motion, and pain relief were assessed. Results Nickel-sensitive patients showed a statistical increase in CD4+ reactivity compared to CD8+ reactivity. The ratio of CD4+/CD8+ T lymphocytes was 1.28 in nickel-sensitive patients versus 0.76 in the control (p = 0.009). There was no difference in functional scores, clinical scores, or range of motion after revision. Conclusions This study provides objective data via histological analysis in support of a nickel allergic sensitization in failed arthroplasties where clinical and/or radiographic abnormalities may not be apparent. Biopsy for CD4+/CD8+ cell counts may provide further proof of the existence of nickel sensitization in lymphocyte stimulation test positive patients, and more importantly, may implore the surgeon to consider low nickel implant design in these patients.
Collapse
Affiliation(s)
- David R Lionberger
- Southwest Orthopedic Group LLC, 6560 Fannin Street, Suite 1016, Scurlock Tower, Houston, TX, 77030, USA.
| | - Justin Samorajski
- Texas A&M College of Medicine, Houston Methodist Hospital, 6565 Fannin Street, Houston, TX, 77030, USA
| | - Charlie D Wilson
- Scott & White Memorial Hospital, 2401 S. 31st St, Temple, TX, 76508, USA
| | - Andreana Rivera
- Department of Pathology, Houston Methodist Hospital, 6565 Fannin Street, Suite M227, Houston, TX, 77030, USA
| |
Collapse
|
28
|
Roczniak W, Brodziak-Dopierała B, Cipora E, Jakóbik-Kolon A, Konieczny M, Babuśka-Roczniak M. Analysis of the Content of Chromium in Certain Parts of the Human Knee Joint. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2018; 15:ijerph15051013. [PMID: 29772846 PMCID: PMC5982052 DOI: 10.3390/ijerph15051013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/07/2018] [Revised: 05/13/2018] [Accepted: 05/14/2018] [Indexed: 12/18/2022]
Abstract
Chromium is an essential microelement in the human body. It exerts an effect on bones by modulating their biochemical parameters: alkaline phosphatase (ALP) and tartrate-resistant acid phosphatase (TRAP). With considerable accumulation of chromium in the skeleton, the activity of alkaline phosphatase was found to decrease, which affected bone formation rate. The study objective was to analyze chromium content in the knee tissues. Tissues for analysis were obtained during endoprosthesoplasty of the knee joint and included tibia, femur, and meniscus tissues. Samples were collected from 50 patients, including 36 women and 14 men. The analysis was performed using the inductively coupled plasma atomic emission spectroscopy (ICP-AES) method, by means of a Varian 710-ES apparatus. The results revealed no significant differences in the content of chromium in the knee joint tissues between women and men. The highest level of chromium was found in the femoral bone of the knee joint, then in the meniscus, and was lowest in the tibia, although the differences were statistically insignificant. Chromium content increased with age.
Collapse
Affiliation(s)
- Wojciech Roczniak
- The Jan Grodek Higher Vocational State School, Medical Institute, 21 Mickiewicza Str., 38-500 Sanok, Poland.
| | - Barbara Brodziak-Dopierała
- Department of Toxicology and Bioanalysis, School of Pharmacy with the Division of Laboratory Medicine, Medical University of Silesia, 4 Jagiellonska Str., 41-200 Sosnowiec, Poland.
| | - Elżbieta Cipora
- The Jan Grodek Higher Vocational State School, Medical Institute, 21 Mickiewicza Str., 38-500 Sanok, Poland.
| | - Agata Jakóbik-Kolon
- Department of Inorganic, Analytical Chemistry and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, 6 B. Krzywoustego Str., 44-100 Gliwice, Poland.
| | - Magdalena Konieczny
- The Jan Grodek Higher Vocational State School, Medical Institute, 21 Mickiewicza Str., 38-500 Sanok, Poland.
| | - Magdalena Babuśka-Roczniak
- The Jan Grodek Higher Vocational State School, Medical Institute, 21 Mickiewicza Str., 38-500 Sanok, Poland.
| |
Collapse
|
29
|
Girard J, Lons A, Pommepuy T, Isida R, Benad K, Putman S. High-impact sport after hip resurfacing: The Ironman triathlon. Orthop Traumatol Surg Res 2017; 103:675-678. [PMID: 28552834 DOI: 10.1016/j.otsr.2017.04.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2017] [Revised: 04/03/2017] [Accepted: 04/06/2017] [Indexed: 02/02/2023]
Abstract
BACKGROUND Returning to high-impact sport is an increasingly frequent functional demand following hip replacement. The literature, however, is sparse on the subject and nonexistent regarding triathlon. We therefore conducted a retrospective study of hip resurfacing in triathlon players, to determine: (1) whether it is possible to return to this kind of sport; (2) if so, whether it is possible to return to the same level; and (3) how a resurfaced hip behaves under these conditions. HYPOTHESIS Hip resurfacing allows return to competition level in long-distance triathlon. MATERIAL AND METHODS A single-center single-operator retrospective study included patients undergoing hip resurfacing with the Conserve Plus implant inserted through a posterolateral approach, who had ceased long-distance triathlon practice due to osteoarthritis of the hip. Fifty-one of the 1688 patients undergoing resurfacing during the inclusion period were long-distance triathlon players. RESULTS The series comprised 48 patients: 51 implants; 43 male, 5 female; mean age, 44.8 years (range, 28.2-58.9 years). At a mean 4.7 years' follow-up (range, 2.2-7.6 years), all clinical scores showed significant improvement; Merle d'Aubigné and Harris scores rose respectively from 12.3 (5-16) and 42 (37-56) preoperatively to 17.5 (13-18) and 93.2 (73-100) (P<0.001). There were no cases of dislocation or implant revision. Forty-five patients returned to sport (94%). Rates of return to swimming, cycling and running were respectively 38/48 (79%), 41/48 (85%) and 33/48 (69%). Preoperatively, all patients had taken part in at least 1 competition: 29 with distance=70.3km and 19 with distance=140.6km. At follow-up, 28 patients had taken part in an Ironman competition: 21 with distance=70.3km and 7 with distance=140.6km. Mean competition performance did not differ between pre and postoperative periods. DISCUSSION Return-to-sport rates were good following hip resurfacing. Non-impact sports (swimming, cycling) predominated postoperatively, whereas the rate of impact sport (running) diminished. Return to competition-level sport (extreme triathlon) was possible for 28/48 patients (58%). Implant survival seemed unaffected by this high-impact sports activity at a mean 4.7 years' follow-up. LEVEL OF EVIDENCE IV, retrospective, non-controlled.
Collapse
Affiliation(s)
- J Girard
- Université de Lille Nord de France, 59000 Lille, France; Département de médecine du sport, faculté de médecine de Lille, université de Lille 2, 59000 Lille, France; Service d'orthopédie C, hôpital Salengro, CHU de Lille, place de Verdun, 59000 Lille, France.
| | - A Lons
- Université de Lille Nord de France, 59000 Lille, France; Service d'orthopédie C, hôpital Salengro, CHU de Lille, place de Verdun, 59000 Lille, France
| | - T Pommepuy
- Université de Lille Nord de France, 59000 Lille, France; Service d'orthopédie C, hôpital Salengro, CHU de Lille, place de Verdun, 59000 Lille, France
| | - R Isida
- Université de Lille Nord de France, 59000 Lille, France; Service d'orthopédie C, hôpital Salengro, CHU de Lille, place de Verdun, 59000 Lille, France
| | - K Benad
- Université de Lille Nord de France, 59000 Lille, France; Service d'orthopédie D, hôpital Salengro, CHU de Lille, place de Verdun, 59000 Lille, France
| | - S Putman
- Université de Lille Nord de France, 59000 Lille, France; Service d'orthopédie D, hôpital Salengro, CHU de Lille, place de Verdun, 59000 Lille, France
| |
Collapse
|
30
|
Martin AJ, Seagers KA, Van Citters DW. Assessment of Corrosion, Fretting, and Material Loss of Retrieved Modular Total Knee Arthroplasties. J Arthroplasty 2017; 32:2279-2284. [PMID: 28343824 DOI: 10.1016/j.arth.2017.02.047] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Revised: 02/10/2017] [Accepted: 02/18/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Modular junctions in total hip arthroplasties have been associated with fretting, corrosion, and debris release. The purpose of this study is to analyze damage severity in total knee arthroplasties of a single design by qualitative visual assessment and quantitative material loss measurements to evaluate implant performance and patient impact via material loss. METHODS Twenty-two modular knee retrievals of the same manufacturer were identified from an institutional review board-approved database. Junction designs included tapers with an axial screw and tapers with a radial screw. Constructs consisted of 2 metal alloys: CoCr and Ti6Al4V. Components were qualitatively scored and quantitatively measured for corrosion and fretting. Negative values represent adhered material. Statistical differences were analyzed using sign tests. Correlations were tested with a Spearman rank order test (P < .05). RESULTS The median volumetric material loss and the maximum linear depth for the total population were -0.23 mm3 and 5.84 μm, respectively. CoCr components in mixed metal junctions had higher maximum linear depth (P = .007) than corresponding Ti components. Fretting scores of Ti6Al4V alloy components in mixed metal junctions were statistically higher than the remaining groups. Taper angle did not correlate with material loss. CONCLUSION Results suggest that CoCr components in mixed metal junctions are more vulnerable to corrosion than other components, suggesting preferential corrosion when interfacing with Ti6Al4V. Overall, although corrosion was noted in this series, material loss was low, and none were revised for clinical metal-related reaction. This suggests the clinical impact from corrosion in total knee arthroplasty is low.
Collapse
Affiliation(s)
- Audrey J Martin
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Kirsten A Seagers
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | | |
Collapse
|
31
|
Lons A, Putman S, Pasquier G, Migaud H, Drumez E, Girard J. Metallic ion release after knee prosthesis implantation: a prospective study. INTERNATIONAL ORTHOPAEDICS 2017; 41:2503-2508. [PMID: 28616704 DOI: 10.1007/s00264-017-3528-9] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2017] [Accepted: 05/25/2017] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Metal-on-metal (MoM) hip replacement bearings produce metallic ions that can cause health complications. Metallic release also occurs with other materials, but data on metallic ion levels after knee arthroplasty are sparse. We postulate that knee replacement generates elevating metallic ions (chromium (Cr), cobalt (Co) and titanium (Ti)) during the first year after implantation. PATIENTS AND METHODS This ongoing prospective study included all patients who underwent the same type of knee arthroplasty between May and December 2013. Cr, Co and Ti levels were measured in whole blood at pre-operation and one-year follow-up (6 and 12 months). Clinical and radiographic data (range of motion, Oxford, International Knee Society (IKS) and satisfaction scores) were recorded. RESULTS In 90 patients, preoperative Cr, Co and Ti metallic ion levels were respectively 0.45 μg/l, 0.22 μg/l, 2.94 μg/l and increased to 1.27 μg/l, 1.41 μg/l, 4.08 μg/l (p < 0.0001) at last one-year follow-up. Mean Oxford and IKS scores rose, respectively, from 45.9 (30-58) and 24.9 (12-52) to 88.3 (0-168) and 160.8 (93-200) (p < 0.001). CONCLUSION After the implantation of knee arthroplasty, we found significant blood elevation of Cr, Co and Ti levels one year after implantation exceeding the normal values. This metallic ion release could lead to numerous effects: allergy, hypersensitivity, etc.
Collapse
Affiliation(s)
- Adrien Lons
- Université de Lille Nord de France, F-59000, Lille, France
- Service d'Orthopédie, Hôpital Salengro, Centre Hospitalier Universitaire de Lille, Place de Verdun, 59037, Lille, Cedex, France
| | - Sophie Putman
- Université de Lille Nord de France, F-59000, Lille, France
- Service d'Orthopédie, Hôpital Salengro, Centre Hospitalier Universitaire de Lille, Place de Verdun, 59037, Lille, Cedex, France
| | - Gilles Pasquier
- Université de Lille Nord de France, F-59000, Lille, France
- Service d'Orthopédie, Hôpital Salengro, Centre Hospitalier Universitaire de Lille, Place de Verdun, 59037, Lille, Cedex, France
| | - Henri Migaud
- Université de Lille Nord de France, F-59000, Lille, France
- Service d'Orthopédie, Hôpital Salengro, Centre Hospitalier Universitaire de Lille, Place de Verdun, 59037, Lille, Cedex, France
| | - Elodie Drumez
- Unité de Biostatistiques, Université Lille, Centre Hospitalier Universitaire Lille, EA 2694 - Santé publique: épidémiologie et qualité des soins, F-59000, Lille, France
| | - Julien Girard
- Université de Lille Nord de France, F-59000, Lille, France.
- Service d'Orthopédie, Hôpital Salengro, Centre Hospitalier Universitaire de Lille, Place de Verdun, 59037, Lille, Cedex, France.
| |
Collapse
|
32
|
Ayoub B, Putman S, Cholewinski P, Paris A, Migaud H, Girard J. Incidence of Adverse Reactions to Metal Debris From 28-mm Metal-on-Metal Total Hip Arthroplasties With Minimum 10 Years of Follow-Up: Clinical, Laboratory, and Ultrasound Assessment of 44 Cases. J Arthroplasty 2017; 32:1206-1210. [PMID: 27988181 DOI: 10.1016/j.arth.2016.11.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2016] [Revised: 10/28/2016] [Accepted: 11/05/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Total hip arthroplasty with metal-on-metal (MoM) bearings has been suspected to cause adverse reactions to metal debris (ARMD), with the incidence varying greatly by implant type and patient gender. The prevalence of ARMD from small-diameter MoM bearings in women is unknown, especially after 10 years of follow-up (FU). METHODS Cementless 28-mm MoM total hip arthroplasty bearings (Metasul) were implanted consecutively in 42 active women between 1996 and 2002. They were reviewed after a minimum of 10 years' FU with clinical, laboratory, radiological, and ultrasound assessments. RESULTS Mean FU was 15.9 years (range, 13-18). The mean Postel-Merle d'Aubigné and Oxford scores were 16.9 (range, 13-18) and 15.1 (range, 12-24), respectively, at FU. Mean cup inclination angle was 46.3° (range, 35°-57°). No femoral osteolysis was detected, but limited acetabular osteolysis (11%) over the screw holes occurred in 5 cases. No liquid or solid synovial reactions or ARMD were apparent on ultrasound, even in the 5 cases of pelvic osteolysis. Mean chromium levels were 1.32 μg/L (range, 0.1-7.9) and cobalt levels were 1.85 μg/L (range, 0.35-13.6). Cobalt was >3 μg/L in only 3 cases. The 15.9-year survivorship was 95% (range, 94.1%-98.9%). CONCLUSION Reliable results were obtained with 28-mm MoM bearings, notably in young, active patients. This implant configuration requires very accurate positioning. No ARMD was seen in this group at 16 years' FU.
Collapse
Affiliation(s)
- Béchir Ayoub
- Université de Lille Nord de France, Lille, France; Service d'orthopédie C, Hôpital Roger Salengro, Place de Verdun, Centre Hospitalier Régional Universitaire de Lille (CHRU de Lille), Lille Cedex, France
| | - Sophie Putman
- Université de Lille Nord de France, Lille, France; Service d'orthopédie C, Hôpital Roger Salengro, Place de Verdun, Centre Hospitalier Régional Universitaire de Lille (CHRU de Lille), Lille Cedex, France
| | - Pierre Cholewinski
- Université de Lille Nord de France, Lille, France; Service d'orthopédie C, Hôpital Roger Salengro, Place de Verdun, Centre Hospitalier Régional Universitaire de Lille (CHRU de Lille), Lille Cedex, France
| | - Amandine Paris
- Université de Lille Nord de France, Lille, France; Service d'orthopédie pédiatrique, Hôpital Jeanne de Flandre, CHRU de Lille, Lille, France
| | - Henri Migaud
- Université de Lille Nord de France, Lille, France; Service d'orthopédie C, Hôpital Roger Salengro, Place de Verdun, Centre Hospitalier Régional Universitaire de Lille (CHRU de Lille), Lille Cedex, France
| | - Julien Girard
- Université de Lille Nord de France, Lille, France; Service d'orthopédie C, Hôpital Roger Salengro, Place de Verdun, Centre Hospitalier Régional Universitaire de Lille (CHRU de Lille), Lille Cedex, France; Département de médecine du sport, Faculté de médecine de Lille, Université de Lille 2, Lille, France
| |
Collapse
|
33
|
Liu Y, Gilbert JL. The effect of simulated inflammatory conditions and Fenton chemistry on the electrochemistry of CoCrMo alloy. J Biomed Mater Res B Appl Biomater 2017; 106:209-220. [DOI: 10.1002/jbm.b.33830] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2016] [Revised: 10/10/2016] [Accepted: 12/01/2016] [Indexed: 12/13/2022]
Affiliation(s)
- Yangping Liu
- Syracuse Biomaterials Institute; Syracuse University; Syracuse New York 13244
- Department of Biomedical and Chemical Engineering; Syracuse University; Syracuse New York 13244
| | - Jeremy L. Gilbert
- Syracuse Biomaterials Institute; Syracuse University; Syracuse New York 13244
- Department of Biomedical and Chemical Engineering; Syracuse University; Syracuse New York 13244
| |
Collapse
|
34
|
Craig R, Vlychou M, McCarthy CL, Gibbons CLMH, Athanasou NA. Metal wear-induced pseudotumour following an endoprosthetic knee replacement for Ewing sarcoma. Skeletal Radiol 2017; 46:967-974. [PMID: 28271180 PMCID: PMC5438826 DOI: 10.1007/s00256-017-2610-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2016] [Revised: 01/19/2017] [Accepted: 02/14/2017] [Indexed: 02/08/2023]
Abstract
Pseudotumours are well recognised as a complication of metal-on-metal hip arthroplasties and are thought to develop on the basis of an innate and adaptive immune response to cobalt-chrome (Co-Cr) wear particles. We report a case of a large pseudotumour that developed following a knee endoprosthetic replacement (EPR) undertaken for Ewing sarcoma. The lesion contained necrotic and degenerate connective tissue in which there were numerous scattered metal wear-containing macrophages, eosinophil polymorphs, lymphocytes, plasma cells and aseptic lymphocyte-dominated vascular-associated lesion-like lymphoid aggregates. Metal ion levels were elevated. No evidence of infection or tumour was noted and it was concluded that the lesion was most likely an inflammatory pseudotumour developing on the basis of an innate and adaptive immune response to components of Co-Cr metal wear derived from the knee EPR.
Collapse
Affiliation(s)
- Richard Craig
- Department of Orthopaedics, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK
| | - Marianna Vlychou
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Department of Histopathology, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK
| | - Catherine L McCarthy
- Department of Radiology, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK
| | | | - N A Athanasou
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Department of Histopathology, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK.
| |
Collapse
|
35
|
Fretting and Corrosion in Modular Shoulder Arthroplasty: A Retrieval Analysis. BIOMED RESEARCH INTERNATIONAL 2016; 2016:1695906. [PMID: 27433471 PMCID: PMC4940522 DOI: 10.1155/2016/1695906] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Accepted: 06/01/2016] [Indexed: 02/08/2023]
Abstract
Tribocorrosion in taper junctions of retrieved anatomic shoulder arthroplasty implants was evaluated. A comparison of the tribocorrosion between cobalt-chromium and titanium alloy stems was conducted and the observations were correlated with the individual's clinical data. Adverse effects caused by metal debris and subsequent elevated serum metal ion levels are frequently reported in total hip arthroplasty. In total shoulder arthroplasty, to date only a small number of retrieval analyses are available and even fewer address the issue of tribocorrosion at the taper junctions. A total of 36 retrieved hemiarthroplasties and total shoulder arthroplasties were assessed using the modified Goldberg score. The prevalence of fretting and corrosion was confirmed in this cohort. Titanium stems seem to be more susceptible to damage caused by tribocorrosion than cobalt-chromium stems. Furthermore, stemless designs offered less tribocorrosion at the taper junction than stemmed designs. A weak correlation between time to revision and increased levels of tribocorrosion was seen. Whether or not tribocorrosion can lead to adverse clinical reactions and causes failure of shoulder arthroplasties remains to be examined.
Collapse
|
36
|
Beyer F, Lützner C, Kirschner S, Lützner J. Midterm Results After Coated and Uncoated TKA: A Randomized Controlled Study. Orthopedics 2016; 39:S13-7. [PMID: 27219721 DOI: 10.3928/01477447-20160509-10] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2016] [Accepted: 02/03/2016] [Indexed: 02/03/2023]
Abstract
Patients undergoing total knee arthroplasty (TKA) who have hypersensitivity to metals usually receive hypoallergenic TKA implants. Coating of a standard implant is a common solution. Although in vitro tests have demonstrated reduction in polyethylene wear for these coatings, it is unknown whether these costly implants have a clinical benefit for patients. One hundred twenty patients undergoing TKA were randomly assigned to receive a novel 7-layer-coating implant or a standard TKA implant. One revision occurred in the standard group, resulting in a calculated 5-year survival of 100% in the coated group and 98.1% in the standard group. The Oxford Knee Score improved substantially in both groups from a mean of 21.6 points preoperatively in the coated group and 21.9 points in the standard group to 39.2 points and 39.2 points, respectively. The current authors observed no adverse effects with the new coating during midterm follow-up. However, longer follow-up time is needed to evaluate possible advantages of this coating. [Orthopedics. 2016; 39(3):S13-S17.].
Collapse
|
37
|
Abstract
Metal hypersensitivity in patients with a total knee arthroplasty (TKA) is a controversial topic. The diagnosis is difficult, given the lack of robust clinical validation of the utility of cutaneous and in vitro testing. Metal hypersensitivity after TKA is quite rare and should be considered after eliminating other causes of pain and swelling, such as low-grade infection, instability, component loosening or malrotation, referred pain, and chronic regional pain syndrome. Anecdotal observations suggest that two clinical presentations of metal hypersensitivity may occur after TKA: dermatitis or a persistent painful synovitis of the knee. Patients may or may not have a history of intolerance to metal jewelry. Laboratory studies, including erythrocyte sedimentation rate, C-reactive protein level, and knee joint aspiration, are usually negative. Cutaneous and in vitro testing have been reported to be positive, but the sensitivity and specificity of such testing has not been defined. Some reports suggest that, if metal hypersensitivity is suspected and nonsurgical measures have failed, then revision to components fabricated of titanium alloy or zirconium coating can be successful in relieving symptoms. Revision should be considered as a last resort, however, and patients should be informed that no evidence-based medicine is available to guide the management of these conditions, particularly for decisions regarding revision. Given the limitations of current testing methods, the widespread screening of patients for metal allergies before TKA is not warranted.
Collapse
|
38
|
Titanium niobium nitride knee implants are not inferior to chrome cobalt components for primary total knee arthroplasty. Arch Orthop Trauma Surg 2015; 135:1749-54. [PMID: 26318754 DOI: 10.1007/s00402-015-2320-9] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2015] [Indexed: 12/20/2022]
Abstract
BACKGROUND Metal allergy in total knee arthroplasty (TKA) is still a controversial topic. Oxinium, ceramic or titanium niobium nitride (TiNbN) coated implants are available for some knee systems. The hypothesis of this study was that the use of TiNbN-coated components would not lead to inferior results compared to conventional implants and that none of the allergic patients receiving TiNbN-coated implants would require revision for metal allergy. MATERIALS AND METHODS This study was a retrospective, 2 to 1 matched pairs study with 40 titanium niobium nitride-coated TKA compared with 80 conventional cobalt chrome implants. No demographic differences between these groups were observed. The mean follow-up for this study was 2 years. RESULTS No differences in clinical, radiological, or patient-reported outcome measurements were observed between the two groups. No patients have been revised at this short- to medium-term outcome evaluation. DISCUSSION Metal allergy leading to contact or systemic dermatitis is especially linked to chrome and cobalt allergy. Nickel allergy because of knee implants rarely gives cutaneous symptoms, but could potentially lead to peri-prosthetic osteolysis and loosening. The use of titanium niobium nitride implants in case of a positive history of metal allergy could avoid this devastating complication. CONCLUSION The use of titanium niobium nitride-coated implants for primary knee osteoarthritis shows similar clinical and radiological outcomes as conventional TKA without revision for loosening at short- to medium-term follow-up. Level of evidence Level IV study.
Collapse
|
39
|
Lons A, Arnould A, Pommepuy T, Drumez E, Girard J. Excellent short-term results of hip resurfacing in a selected population of young patients. Orthop Traumatol Surg Res 2015; 101:661-5. [PMID: 26362039 DOI: 10.1016/j.otsr.2015.07.011] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2015] [Revised: 07/01/2015] [Accepted: 07/17/2015] [Indexed: 02/02/2023]
Abstract
BACKGROUND Hip resurfacing (HR) is an alternative option to total hip arthroplasty (THA) in a population of selected patients (young and/or active). HYPOTHESIS The short-term survivorship rate is as least as good as that for THA with no abnormal increase in serum metal ion levels. MATERIALS AND METHODS A continuous prospective series of 502 hip resurfacings in 481 patients mean age 48.7 years old (±10.3; 18-68) (Conserve Plus, Wright Medical Technology) was analyzed clinically, radiologically and biologically (total blood chrome, cobalt and titanium metal ion levels). Mean follow up was 4.1 years (1.9-4.9). RESULTS There were no dislocations. There were 5 cases of revision surgery with component replacement (including 2 infections). Implant survivorship using implant removal as the criteria (excluding infection) was 99.4% at 4 years (CI 95%: 98.1-99.8). The evaluation of metal ion levels showed a significant increase in cobalt from a preoperative level of 0.24 μg/L (0.01-3.6) to 0.86 μg/L (0.01-5.7) at the final follow-up (P<0.001). Chrome and titanium levels went from 0.68 μg/L (0.01-4.4) and 2.36 μg/L (0.39-7) to 1.28 μg/L (0.1-5.5) and 4.49 μg/L (1.29-8.21) respectively (P<0.001). All clinical scores had significantly improved at the final follow-up. Mean frontal plane cup inclination was 42.7° (35-62). DISCUSSION In a selected population of young and/or active patients, the short-term results of hip resurfacing are excellent. At the postoperative 4-year follow-up the rate of complications (in particular the absence of dislocations) was less than that for THA in young and/or active patients. Certain conditions must be respected to obtain these results; frontal plane cup inclination of between 40 and 45°, a femoral head diameter of at least 48 mm and good quality femoral bone. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- A Lons
- Université Lille Nord de France, 59000 Lille, France; Service d'orthopédie C, hôpital Salengro, place de Verdun, CHU de Lille, 59000 Lille, France
| | - A Arnould
- Université Lille Nord de France, 59000 Lille, France; Service d'orthopédie D, hôpital Salengro, place de Verdun, CHU de Lille, 59000 Lille, France
| | - T Pommepuy
- Université Lille Nord de France, 59000 Lille, France; Service d'orthopédie C, hôpital Salengro, place de Verdun, CHU de Lille, 59000 Lille, France
| | - E Drumez
- Université Lille Nord de France, 59000 Lille, France; Unité biostatistiques pôle santé publique, maison régionale de la recherche clinique, CERIM, 154, rue du Docteur-Yersin, 59000 Lille, France
| | - J Girard
- Université Lille Nord de France, 59000 Lille, France; Département de médecine du sport, faculté de médecine de Lille, université de Lille 2, Lille, France; Service d'orthopédie C, hôpital Salengro, place de Verdun, CHU de Lille, 59000 Lille, France.
| |
Collapse
|
40
|
van Hove RP, Brohet RM, van Royen BJ, Nolte PA. No clinical benefit of titanium nitride coating in cementless mobile-bearing total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2015; 23:1833-40. [PMID: 25283502 DOI: 10.1007/s00167-014-3359-9] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2014] [Accepted: 09/25/2014] [Indexed: 12/20/2022]
Abstract
PURPOSE Titanium nitride (TiN) coating of cobalt-chromium-molybdenum (CoCrMo) implants has shown to improve the biomechanical properties of the implant surface and to reduce adhesive wear in vitro. It is yet unknown whether TiN coating of total knee prosthesis (TKP) affects the postoperative clinical outcome of total knee arthroplasty (TKA). METHODS In a double-blind randomized controlled clinical trial, 101 patients received an uncemented mobile-bearing CoCrMo TKP, either TiN coated or uncoated. Primary outcome measure visual analogue scale (VAS) score for pain, and secondary outcome measures Knee Society Score (KSS), revision rate and adverse events, range of motion of the knee as well as knee circumference and knee skin temperature were assessed 6 weeks, 6 months, 1 year and 5 years postoperative. Repeated measures analysis was used to evaluate the postoperative outcome measures over time. RESULTS There was no difference between the two groups in VAS score, KSS, revision rate, range of motion of the knee, knee circumference and knee skin temperature. There were no adverse events that could be related to the TiN coating. CONCLUSIONS TiN-coated TKP does not influence the postoperative outcome of uncemented mobile-bearing TKA regarding postoperative pain, revision rate, range of motion, swelling and temperature of the knee. Therefore, TiN coating of CoCrMo TKP has no clinical benefit on the outcome of cementless mobile-bearing TKA. LEVEL OF EVIDENCE Therapeutic study, Level I.
Collapse
Affiliation(s)
- Ruud P van Hove
- Department of Orthopaedics, Spaarne Hospital, Spaarnepoort 1, 2134 TM, Hoofddorp, The Netherlands,
| | | | | | | |
Collapse
|
41
|
Biomaterial hypersensitivity: is it real? Supportive evidence and approach considerations for metal allergic patients following total knee arthroplasty. BIOMED RESEARCH INTERNATIONAL 2015; 2015:137287. [PMID: 25883940 PMCID: PMC4390183 DOI: 10.1155/2015/137287] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/28/2014] [Accepted: 09/19/2014] [Indexed: 12/20/2022]
Abstract
The prospect of biomaterial hypersensitivity developing in response to joint implant materials was first presented more than 30 years ago. Many studies have established probable causation between first-generation metal-on-metal hip implants and hypersensitivity reactions. In a limited patient population, implant failure may ultimately be related to metal hypersensitivity. The examination of hypersensitivity reactions in current-generation metal-on-metal knee implants is comparatively limited. The purpose of this study is to summarize all available literature regarding biomaterial hypersensitivity after total knee arthroplasty, elucidate overall trends about this topic in the current literature, and provide a foundation for clinical approach considerations when biomaterial hypersensitivity is suspected.
Collapse
|
42
|
Assessment of Patients with a DePuy ASR Metal-on-Metal Hip Replacement: Results of Applying the Guidelines of the Spanish Society of Hip Surgery in a Tertiary Referral Hospital. Adv Orthop 2014; 2014:982523. [PMID: 25431677 PMCID: PMC4241718 DOI: 10.1155/2014/982523] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2014] [Accepted: 10/21/2014] [Indexed: 12/12/2022] Open
Abstract
The prognosis associated with the DePuy ASR hip cup is poor and varies according to the series. This implant was withdrawn from use in 2010 and all patients needed to be assessed. We present the results of the assessment of our patients treated with this device, according to the Spanish Society of Hip Surgery (SECCA) algorithm published in 2011. This retrospective study evaluates 83 consecutive ASR cups, followed up at a mean of 2.9 years. Serum levels of chromium and cobalt, as well as the acetabular abduction angle, were determined in order to assess their possible correlation with failure, defined as the need for revision surgery. The mean Harris Hip Score was 83.2 (range 42–97). Eight arthroplasties (13.3%) required revision due to persistent pain and/or elevated serum levels of chromium/cobalt. All the cups had a correct abduction angle, and there was no correlation between elevated serum levels of metal ions and implant failure. Since two previous ASR implants were exchanged previously to the recall, the revision rate for ASR cups in our centre is 18.2% at 2.9 years.
Collapse
|
43
|
Molecular analysis of chromium and cobalt-related toxicity. Sci Rep 2014; 4:5729. [PMID: 25034144 PMCID: PMC4103093 DOI: 10.1038/srep05729] [Citation(s) in RCA: 115] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2014] [Accepted: 06/27/2014] [Indexed: 12/12/2022] Open
Abstract
Occupational and environmental exposure to Co and Cr has been previously linked to a wide array of inflammatory and degenerative conditions and cancer. Recently, significant health concerns have been raised by the high levels of Cr and Co ions and corrosion products released by biomedical implants. Herein, we set to analyze the biological responses associated with Co and Cr toxicity. Histological, ultrastructural, and elemental analysis, performed on Cr and Co exposed patients reveal the presence of corrosion products, metallic wear debris and metal ions at varying concentrations. Metallic ions and corrosion products were also generated in vitro following macrophage phagocytosis of metal alloys. Ex vivo redox proteomic mapped several oxidatively damaged proteins by Cr(III) and Co(II)-induced Fenton reaction. Importantly, a positive correlation between the tissue amounts of Cr(III) and Co(II) ions and tissue oxidative damage was observed. Immobilized- Cr(III) and Co(II) affinity chromatography indicated that metal ions can also directly bind to several metallo and non-metalloproteins and, as demonstrated for aldolase and catalase, induce loss of their biological function. Altogether, our analysis reveals several biological mechanisms leading to tissue damage, necrosis, and inflammation in patients with Cr and Co-associated adverse local tissue reactions.
Collapse
|
44
|
Matusiewicz H. Potential release of in vivo trace metals from metallic medical implants in the human body: from ions to nanoparticles--a systematic analytical review. Acta Biomater 2014; 10:2379-403. [PMID: 24565531 DOI: 10.1016/j.actbio.2014.02.027] [Citation(s) in RCA: 116] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2013] [Revised: 12/04/2013] [Accepted: 02/13/2014] [Indexed: 02/06/2023]
Abstract
Metal ion release from metallic materials, e.g. metallic alloys and pure metals, implanted into the human body in dental and orthopedic surgery is becoming a major cause for concern. This review briefly provides an overview of both metallic alloys and pure metals used in implant materials in dental and orthopedic surgery. Additionally, a short section is dedicated to important biomaterials and their corrosive behavior in both real solutions and various types of media that model human biological fluids and tissues. The present review gives an overview of analytical methods, techniques and different approaches applied to the measurement of in vivo trace metals released into body fluids and tissues from patients carrying metal-on-metal prostheses and metal dental implants. Reference levels of ion concentrations in body fluids and tissues that have been determined by a host of studies are compiled, reviewed and presented in this paper. Finally, a collection of published clinical data on in vivo released trace metals from metallic medical implants is included.
Collapse
|
45
|
Affiliation(s)
- Ole Reigstad
- Hand- and Microsurgery section Orthopaedic department OUS-Rikshospitalet Postboks 4950 Nydalen 0424 Oslo Norway
| |
Collapse
|
46
|
Kretzer JP, Reinders J, Sonntag R, Hagmann S, Streit M, Jeager S, Moradi B. Wear in total knee arthroplasty--just a question of polyethylene?: Metal ion release in total knee arthroplasty. INTERNATIONAL ORTHOPAEDICS 2013; 38:335-40. [PMID: 24218115 DOI: 10.1007/s00264-013-2162-4] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2013] [Accepted: 10/20/2013] [Indexed: 11/25/2022]
Abstract
PURPOSE Biological reactions against wear particles are a common cause for revision in total knee arthroplasty. To date, wear has mainly been attributed to polyethylene. However, the implants have large metallic surfaces that also could potentially lead to metal wear products (metal ions and debris). The aim of this study was to determine the local release of cobalt, chromium, molybdenum and titanium in total knee arthroplasty during a standard knee wear test. METHODS Four moderately conforming fixed-bearing implants were subjected to physiological loadings and motions for 5×10(6) walking cycles in a knee wear simulator. Polyethylene wear was determined gravimetrically and the release of metallic wear products was measured using high resolution-inductively coupled plasma-mass spectrometry. RESULTS A polyethylene wear rate of 7.28 ± 0.27 mg/10(6) cycles was determined and the cumulative mass of released metals measured 1.63 ± 0.28 mg for cobalt, 0.47 ± 0.06 mg for chromium, 0.42 ± 0.06 mg for molybdenum and 1.28 ± 0.14 mg for titanium. CONCLUSION For other metallic implants such as metal-on-metal total hip arthroplasty, the metal wear products can interact with the immune system, potentially leading to immunotoxic effects. In this study about 12 % by weight of the wear products were metallic, and these particles and ions may become clinically relevant for patients sensitive to these materials in particular. Non-metallic materials (e.g. ceramics or suitable coatings) may be considered for an alternative treatment for those patients.
Collapse
Affiliation(s)
- Jan Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Department of Orthopaedics & Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany,
| | | | | | | | | | | | | |
Collapse
|
47
|
Lützner J, Hartmann A, Dinnebier G, Spornraft-Ragaller P, Hamann C, Kirschner S. Metal hypersensitivity and metal ion levels in patients with coated or uncoated total knee arthroplasty: a randomised controlled study. INTERNATIONAL ORTHOPAEDICS 2013; 37:1925-31. [PMID: 23860793 PMCID: PMC3779567 DOI: 10.1007/s00264-013-2010-6] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2013] [Accepted: 06/24/2013] [Indexed: 12/23/2022]
Abstract
PURPOSE Metal ion release by orthopaedic implants may cause local and systemic effects and induce hypersensitivity reactions. Coated implants have been developed to prevent or reduce these effects. This study was initiated to investigate the safety of a novel coating for total knee arthroplasty (TKA) implants. METHODS A total of 120 patients undergoing primary TKA with no history of hypersensitivity and no other metal implant were randomised to receive either a coated or uncoated implant. Chromium (Cr), cobalt (Co), molybdenum (Mb) and nickel (Ni) hypersensitivity patch testing and plasma ion concentrations were evaluated pre-operatively and one year post-operatively. RESULTS At the one year follow-up both groups demonstrated significant improvement in knee function and quality of life. One new weakly positive reaction to Co in the TKA group with coated implant and two doubtful skin reactions to Ni (one in each group) were noted. Even with sensitisation to implant materials no skin reactions were observed. Plasma metal ion concentrations did not increase and were not elevated at the one year follow-up in either group. CONCLUSIONS Sensitisation after TKA was rare and had no influence on clinical results. TKA with coated implant and standard TKA demonstrated no plasma metal ion elevation.
Collapse
Affiliation(s)
- Jörg Lützner
- Department of Orthopaedic Surgery, University Hospital Carl Gustav Carus, Medical Faculty of the Technical University of Dresden, Fetscherstr. 74, 01307, Dresden, Germany,
| | | | | | | | | | | |
Collapse
|
48
|
In-vitro-Analyse des Einflusses von Metallionen auf humane Lymphozyten. DER ORTHOPADE 2013; 42:643-50. [DOI: 10.1007/s00132-012-2039-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
49
|
Biotribology of a new bearing material combination in a rotating hinge knee articulation. Acta Biomater 2013; 9:7054-63. [PMID: 23485855 DOI: 10.1016/j.actbio.2013.02.030] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2012] [Revised: 01/25/2013] [Accepted: 02/16/2013] [Indexed: 12/13/2022]
Abstract
The objective of the present study was to evaluate the biotribological behaviour, in terms of wear and particle release, of bushings and flanges made of carbon fibre reinforced poly-ether-ether-ketone (CFR-PEEK) in articulation with a zirconium nitride (ZrN) multilayer surface coating in a rotating hinge knee system. For the bushings of the rotational and flexion axles and the medial and lateral flanges, a CFR-PEEK with 30% polyacrylonitrile fibre content was used in a new bearing combination with ZrN. In vitro wear simulation was performed for patients with metal ion hypersensitivity, using a new rotating hinge knee design with a ZrN surface articulation in comparison with the clinically established cobalt-chromium version. For the bushings and flanges made of CFR-PEEK subjected to wear simulation, the volumetric wear rates were 2.3±0.48mm(3)million(-1) cycles in articulation to cobalt-chromium as reference and 0.21±0.02mm(3)million(-1) cycles in the coupling with ZrN, a 10.9-fold decrease. The released CFR-PEEK particles were comparable in size and shape for the coupling to cobalt-chromium and ZrN with most of the particles in a size range between 0.1 and 2μm. The study reveals comparable low wear and no macroscopic surface fatigue in a new rotating hinge knee design with highly congruent flanges and axles bushings made of CFR-PEEK articulating to a ZrN multilayer surface coating. Favourable wear behaviour of the newly introduced CFR-PEEK/ZrN coupling in comparison with the clinically established CFR-PEEK/cobalt-chromium articulation was found.
Collapse
|
50
|
McMaster WC, Patel J. Adverse local tissue response lesion of the knee associated with Morse taper corrosion. J Arthroplasty 2013; 28:375.e5-8. [PMID: 22704030 DOI: 10.1016/j.arth.2012.04.005] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2011] [Accepted: 04/04/2012] [Indexed: 02/01/2023] Open
Abstract
Modularity in arthroplasty components has increased options for solving complex issues in primary and revision procedures. However, this technology introduces the risk of accelerated metal ion release as a result of fretting or passive crevice corrosion within the Morse taper junction. Cobalt toxicity locally and systemically has been described with hip metal bearing surfaces and may be accentuated with ion release from Morse tapers. This is a case report of a knee adverse local tissue response lesion associated with corrosion within the Morse taper of a revision knee arthroplasty in the absence of systemic metal allergy.
Collapse
Affiliation(s)
- William C McMaster
- Long Beach VA Medical Center, Section of Orthopaedic Surgery, Long Beach, California, USA
| | | |
Collapse
|