Xu B, Jiang F, Zhu Z, Meng H, Xu L. Adaptive convolutional dictionary learning for denoising seismocardiogram to enhance the classification performance of aortic stenosis. Comput Biol Med 2024; 168:107763. [PMID: 38056208 DOI: 10.1016/j.compbiomed.2023.107763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 11/16/2023] [Accepted: 11/21/2023] [Indexed: 12/08/2023]
Abstract
BACKGROUND Aortic stenosis (AS) is the most prevalent type of valvular heart disease (VHD), traditionally diagnosed using echocardiogram or phonocardiogram. Seismocardiogram (SCG), an emerging wearable cardiac monitoring modality, is proved to be feasible in non-invasive and cost-effective AS diagnosis. However, SCG waveforms acquired from patients with heart diseases are typically weak, making them more susceptible to noise contamination. While most related researches focus on motion artifacts, sensor noise and quantization noise have been mostly overlooked. These noises pose additional challenges for extracting features from the SCG, especially impeding accurate AS classification. METHOD To address this challenge, we present a convolutional dictionary learning-based method. Based on sparse modeling of SCG, the proposed method generates a personalized adaptive-size dictionary from noisy measurements. The dictionary is used for sparse coding of the noisy SCG into a transform domain. Reconstruction from the domain removes the noise while preserving the individual waveform pattern of SCG. RESULTS Using two self-collected SCG datasets, we established optimal dictionary learning parameters and validated the denoising performance. Subsequently, the proposed method denoised SCG from 50 subjects (25 AS and 25 non-AS). Leave-one-subject-out cross-validation (LOOCV) was applied to 5 machine learning classifiers. Among the classifiers, a bi-layer neural network achieved a moderate accuracy of 90.2%, with an improvement of 13.8% from the denoising. CONCLUSIONS The proposed sparsity-based denoising technique effectively removes stochastic sensor noise and quantization noise from SCG, consequently improving AS classification performance. This approach shows promise for overcoming instrumentation constraints of SCG-based diagnosis.
Collapse
Affiliation(s)
- Bowen Xu
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, 110169, China; Key Laboratory of Medical Image Computing, Ministry of Education, Shenyang, 110169, China
| | - Fangfang Jiang
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, 110169, China; Key Laboratory of Medical Image Computing, Ministry of Education, Shenyang, 110169, China.
| | - Ziyu Zhu
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, 110169, China; Key Laboratory of Medical Image Computing, Ministry of Education, Shenyang, 110169, China
| | - Haobo Meng
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, 110169, China; Key Laboratory of Medical Image Computing, Ministry of Education, Shenyang, 110169, China
| | - Lisheng Xu
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, 110169, China; Key Laboratory of Medical Image Computing, Ministry of Education, Shenyang, 110169, China
| |
Collapse
|
2
|
Santucci F, Nobili M, Presti DL, Massaroni C, Setola R, Schena E, Oliva G. Waveform Similarity Analysis Using Graph Mining for the Optimization of Sensor Positioning in Wearable Seismocardiography. IEEE Trans Biomed Eng 2023; 70:2788-2798. [PMID: 37027279 DOI: 10.1109/tbme.2023.3264940] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/08/2023]
Abstract
OBJECTIVE A major concern with wearable devices aiming to measure the seismocardiogram (SCG) signal is the variability of SCG waveform with the sensor position and a lack of a standard measurement procedure. We propose a method to optimize sensor positioning based on the similarity among waveforms collected through repeated measurements. METHOD we design a graph-theoretical model to evaluate the similarity of SCG signals and apply the proposed methodology to signals collected by sensors placed in different positions on the chest. A similarity score returns the optimal measurement position based on the repeatability of SCG waveforms. We tested the methodology on signals collected by using two wearable patches based on optical technology placed in two positions: mitral and aortic valve auscultation site (inter-position analysis). 11 healthy subjects were enrolled in this study. Moreover, we evaluated the influence of the subject's posture on waveform similarity with a view on ambulatory use (inter-posture analysis). RESULTS the highest similarity among SCG waveforms is obtained with the sensor on the mitral valve and the subject lying down. CONCLUSIONS our approach aims to be a step forward in the optimization of sensor positioning in the field of wearable seismocardiography. We demonstrate that the proposed algorithm is an effective method to estimate similarity among waveforms and outperforms the state-of-the-art in comparing SCG measurement sites. SIGNIFICANCE results obtained from this study can be exploited to design more efficient protocols for SCG recording in both research studies and future clinical examinations.
Collapse
|
3
|
Lin DJ, Gazi AH, Kimball J, Nikbakht M, Inan OT. Real-Time Seismocardiogram Feature Extraction Using Adaptive Gaussian Mixture Models. IEEE J Biomed Health Inform 2023; 27:3889-3899. [PMID: 37155395 DOI: 10.1109/jbhi.2023.3273989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Wearable systems can provide accurate cardiovascular evaluations by estimating hemodynamic indices in real-time. Key hemodynamic parameters can be non-invasively estimated using the seismocardiogram (SCG), a cardiomechanical signal whose features link to cardiac events like aortic valve opening (AO) and closing (AC). However, tracking a single SCG feature is unreliable due to physiological changes, motion artifacts, and external vibrations. This work proposes an adaptable Gaussian Mixture Model (GMM) to track multiple AO/AC correlated features in quasi-real-time from the SCG. The GMM calculates the likelihood of an extremum being an AO/AC feature for each SCG beat. The Dijkstra algorithm selects heartbeat-related extrema, and a Kalman filter updates the GMM parameters while filtering features. Tracking accuracy is tested on a porcine hypovolemia dataset with varying noise levels. Blood volume loss estimation accuracy is also evaluated using the tracked features on a previously developed model. Experimental results show a 4.5 ms tracking latency and average root mean square errors (RMSE) of 1.47 ms for AO and 7.67 ms for AC at 10 dB noise, and 6.18 ms for AO and 15.3 ms for AC at -10 dB noise. When considering all AO/AC correlated features, the combined RMSE remains in similar ranges, specifically 2.70 ms for AO and 11.91 ms for AC at 10 dB noise, and 7.50 ms for AO and 16.35 ms for AC at -10 dB noise. The proposed algorithm offers low latency and RMSE for all tracked features, making it suitable for real-time processing. These systems enable accurate, timely extraction of hemodynamic indices for many cardiovascular monitoring applications, including trauma care in field settings.
Collapse
|
4
|
Soliman MM, Ganti VG, Inan OT. Towards Wearable Estimation of Tidal Volume via Electrocardiogram and Seismocardiogram Signals. IEEE SENSORS JOURNAL 2022; 22:18093-18103. [PMID: 37091042 PMCID: PMC10120872 DOI: 10.1109/jsen.2022.3196601] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The current COVID-19 pandemic highlights the critical importance of ubiquitous respiratory health monitoring. The two fundamental elements of monitoring respiration are respiration rate (the frequency of breathing) and tidal volume (TV, the volume of air breathed by the lungs in each breath). Wearable sensing systems have been demonstrated to provide accurate measurement of respiration rate, but TV remains challenging to measure accurately with wearable and unobtrusive technology. In this work, we leveraged electrocardiogram (ECG) and seismocardiogram (SCG) measurements obtained with a custom wearable sensing patch to derive an estimate of TV from healthy human participants. Specifically, we fused both ECG-derived and SCG-derived respiratory signals (EDR and SDR) and trained a machine learning model with gas rebreathing as the ground truth to estimate TV. The respiration cycle modulates ECG and SCG signals in multiple different ways that are synergistic. Thus, here we extract EDRs and SDRs using a multitude of different demodulation techniques. The extracted features are used to train a subject independent machine learning model to accurately estimate TV. By fusing the extracted EDRs and SDRs, we were able to estimate the TV with a root-mean-square error (RMSE) of 181.45 mL and Pearson correlation coefficient (r) of 0.61, with a global subject-independent model. We further show that SDRs are better TV estimators than EDRs. Among SDRs, amplitude modulated (AM) SCG features are the most correlated to TV. We demonstrated that fusing EDRs and SDRs can result in moderately accurate estimation of TV using a subject-independent model. Additionally, we highlight the most informative features for estimating TV. This work presents a significant step towards achieving continuous, calibration free, and unobtrusive TV estimation, which could advance the state of the art in wearable respiratory monitoring.
Collapse
Affiliation(s)
- Moamen M Soliman
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332
| | - Venu G Ganti
- Bioengineering Graduate Program, Georgia Institute of Technology, Atlanta, GA 30332
| | - Omer T Inan
- School of Electrical and Computer Engineering and, by courtesy, the Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332
| |
Collapse
|
5
|
Chan M, Ganti VG, Inan OT. Respiratory Rate Estimation Using U-Net-Based Cascaded Framework From Electrocardiogram and Seismocardiogram Signals. IEEE J Biomed Health Inform 2022; 26:2481-2492. [PMID: 35077375 PMCID: PMC9248781 DOI: 10.1109/jbhi.2022.3144990] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/14/2023]
Abstract
OBJECTIVE At-home monitoring of respiration is of critical urgency especially in the era of the global pandemic due to COVID-19. Electrocardiogram (ECG) and seismocardiogram (SCG) signals-measured in less cumbersome contact form factors than the conventional sealed mask that measures respiratory air flow-are promising solutions for respiratory monitoring. In particular, respiratory rates (RR) can be estimated from ECG-derived respiratory (EDR) and SCG-derived respiratory (SDR) signals. Yet, non-respiratory artifacts might still be present in these surrogates of respiratory signals, hindering the accuracy of the RRs estimated. METHODS In this paper, we propose a novel U-Net-based cascaded framework to address this problem. The EDR and SDR signals were transformed to the spectro-temporal domain and subsequently denoised by a 2D U-Net to reduce the non-respiratory artifacts. MAJOR RESULTS We have shown that the U-Net that fused an EDR input and an SDR input achieved a low mean absolute error of 0.82 breaths per minute (bpm) and a coefficient of determination (R2) of 0.89 using data collected from our chest-worn wearable patch. We also qualitatively provided insights on the complementariness between EDR and SDR signals and demonstrated the generalizability of the proposed framework. CONCLUSION ECG and SCG collected from a chest-worn wearable patch can complement each other and yield reliable RR estimation using the proposed cascaded framework. SIGNIFICANCE We anticipate that convenient and comfortable ECG and SCG measurement systems can be augmented with this framework to facilitate pervasive and accurate RR measurement.
Collapse
|
6
|
Rossi M, Alessandrelli G, Dombrovschi A, Bovio D, Salito C, Mainardi L, Cerveri P. Identification of Characteristic Points in Multivariate Physiological Signals by Sensor Fusion and Multi-Task Deep Networks. SENSORS 2022; 22:s22072684. [PMID: 35408297 PMCID: PMC9003131 DOI: 10.3390/s22072684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 03/28/2022] [Accepted: 03/28/2022] [Indexed: 11/28/2022]
Abstract
Identification of characteristic points in physiological signals, such as the peak of the R wave in the electrocardiogram and the peak of the systolic wave of the photopletismogram, is a fundamental step for the quantification of clinical parameters, such as the pulse transit time. In this work, we presented a novel neural architecture, called eMTUnet, to automate point identification in multivariate signals acquired with a chest-worn device. The eMTUnet consists of a single deep network capable of performing three tasks simultaneously: (i) localization in time of characteristic points (labeling task), (ii) evaluation of the quality of signals (classification task); (iii) estimation of the reliability of classification (reliability task). Preliminary results in overnight monitoring showcased the ability to detect characteristic points in the four signals with a recall index of about 1.00, 0.90, 0.90, and 0.80, respectively. The accuracy of the signal quality classification was about 0.90, on average over four different classes. The average confidence of the correctly classified signals, against the misclassifications, was 0.93 vs. 0.52, proving the worthiness of the confidence index, which may better qualify the point identification. From the achieved outcomes, we point out that high-quality segmentation and classification are both ensured, which brings the use of a multi-modal framework, composed of wearable sensors and artificial intelligence, incrementally closer to clinical translation.
Collapse
Affiliation(s)
- Matteo Rossi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy; (G.A.); (A.D.); (L.M.)
- Correspondence: (M.R.); (P.C.)
| | - Giulia Alessandrelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy; (G.A.); (A.D.); (L.M.)
| | - Andra Dombrovschi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy; (G.A.); (A.D.); (L.M.)
| | - Dario Bovio
- Biocubica SRL, 20154 Milan, Italy; (D.B.); (C.S.)
| | | | - Luca Mainardi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy; (G.A.); (A.D.); (L.M.)
| | - Pietro Cerveri
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy; (G.A.); (A.D.); (L.M.)
- Correspondence: (M.R.); (P.C.)
| |
Collapse
|
7
|
Işilay Zeybek ZM, Racca V, Pezzano A, Tavanelli M, Di Rienzo M. Can Seismocardiogram Fiducial Points Be Used for the Routine Estimation of Cardiac Time Intervals in Cardiac Patients? Front Physiol 2022; 13:825918. [PMID: 35399285 PMCID: PMC8986454 DOI: 10.3389/fphys.2022.825918] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Accepted: 02/10/2022] [Indexed: 11/18/2022] Open
Abstract
The indexes of cardiac mechanics can be derived from the cardiac time intervals, CTIs, i.e., the timings among the opening and closure of the aortic and mitral valves and the Q wave in the ECG. Traditionally, CTIs are estimated by ultrasound (US) techniques, but they may also be more easily assessed by the identification of specific fiducial points (FPs) inside the waveform of the seismocardiogram (SCG), i.e., the measure of the thorax micro-accelerations produced by the heart motion. While the correspondence of the FPs with the valve movements has been verified in healthy subjects, less information is available on whether this methodology may be routinely employed in the clinical practice for the monitoring of cardiac patients, in which an SCG waveform distortion is expected because of the heart dysfunction. In this study we checked the SCG shape in 90 patients with myocardial infarction (MI), heart failure (HF), or transplanted heart (TX), referred to our hospital for rehabilitation after an acute event or after surgery. The SCG shapes were classified as traditional (T) or non-traditional (NT) on whether the FPs were visible or not on the basis of nomenclature previously proposed in literature. The T shape was present in 62% of the patients, with a higher ∓ prevalence in MI (79%). No relationship was found between T prevalence and ejection fraction (EF). In 20 patients with T shape, we checked the FPs correspondence with the real valve movements by concomitant SCG and US measures. When compared with reference values in healthy subjects available in the literature, we observed that the Echo vs. FP differences are significantly more dispersed in the patients than in the healthy population with higher differences for the estimation of the mitral valve closure (−17 vs. 4 ms on average). Our results indicate that not every cardiac patient has an SCG waveform suitable for the CTI estimation, thus before starting an SCG-based CTI monitoring a preliminary check by a simultaneous SCG-US measure is advisable to verify the applicability of the methodology.
Collapse
Affiliation(s)
| | - Vittorio Racca
- Cardiac Rehabilitation Unit, IRCCS Fondazione Don Carlo Gnocchi ONLUS, Milan, Italy
| | - Antonio Pezzano
- Cardiac Rehabilitation Unit, IRCCS Fondazione Don Carlo Gnocchi ONLUS, Milan, Italy
| | - Monica Tavanelli
- Cardiac Rehabilitation Unit, IRCCS Fondazione Don Carlo Gnocchi ONLUS, Milan, Italy
| | - Marco Di Rienzo
- WeST Lab, IRCCS Fondazione Don Carlo Gnocchi ONLUS, Milan, Italy
- *Correspondence: Marco Di Rienzo,
| |
Collapse
|
8
|
Centracchio J, Andreozzi E, Esposito D, Gargiulo GD, Bifulco P. Detection of Aortic Valve Opening and Estimation of Pre-Ejection Period in Forcecardiography Recordings. Bioengineering (Basel) 2022; 9:bioengineering9030089. [PMID: 35324778 PMCID: PMC8945374 DOI: 10.3390/bioengineering9030089] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 02/14/2022] [Accepted: 02/18/2022] [Indexed: 11/16/2022] Open
Abstract
Forcecardiography (FCG) is a novel technique that measures the local forces induced on the chest wall by the mechanical activity of the heart. Specific piezoresistive or piezoelectric force sensors are placed on subjects’ thorax to measure these very small forces. The FCG signal can be divided into three components: low-frequency FCG, high-frequency FCG (HF-FCG) and heart sound FCG. HF-FCG has been shown to share a high similarity with the Seismocardiogram (SCG), which is commonly acquired via small accelerometers and is mainly used to locate specific fiducial markers corresponding to essential events of the cardiac cycle (e.g., heart valves opening and closure, peaks of blood flow). However, HF-FCG has not yet been demonstrated to provide the timings of these markers with reasonable accuracy. This study addresses the detection of the aortic valve opening (AO) marker in FCG signals. To this aim, simultaneous recordings from FCG and SCG sensors were acquired, together with Electrocardiogram (ECG) recordings, from a few healthy subjects at rest, both during quiet breathing and apnea. The AO markers were located in both SCG and FCG signals to obtain pre-ejection periods (PEP) estimates, which were compared via statistical analyses. The PEPs estimated from FCG and SCG showed a strong linear relationship (r > 0.95) with a practically unit slope, and 95% of their differences were found to be distributed within ± 4.6 ms around small biases of approximately 1 ms, corresponding to percentage differences lower than 5% of the mean measured PEP. These preliminary results suggest that FCG can provide accurate AO timings and PEP estimates.
Collapse
Affiliation(s)
- Jessica Centracchio
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21 80125 Napoli, Italy; (J.C.); (D.E.); (P.B.)
| | - Emilio Andreozzi
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21 80125 Napoli, Italy; (J.C.); (D.E.); (P.B.)
- Correspondence:
| | - Daniele Esposito
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21 80125 Napoli, Italy; (J.C.); (D.E.); (P.B.)
| | - Gaetano Dario Gargiulo
- School of Engineering, Design and Built Environment, Western Sydney University, Penrith 2751, Australia;
| | - Paolo Bifulco
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21 80125 Napoli, Italy; (J.C.); (D.E.); (P.B.)
| |
Collapse
|
9
|
Wearable Sensors and Machine Learning for Hypovolemia Problems in Occupational, Military and Sports Medicine: Physiological Basis, Hardware and Algorithms. SENSORS 2022; 22:s22020442. [PMID: 35062401 PMCID: PMC8781307 DOI: 10.3390/s22020442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 12/14/2021] [Accepted: 12/30/2021] [Indexed: 11/16/2022]
Abstract
Hypovolemia is a physiological state of reduced blood volume that can exist as either (1) absolute hypovolemia because of a lower circulating blood (plasma) volume for a given vascular space (dehydration, hemorrhage) or (2) relative hypovolemia resulting from an expanded vascular space (vasodilation) for a given circulating blood volume (e.g., heat stress, hypoxia, sepsis). This paper examines the physiology of hypovolemia and its association with health and performance problems common to occupational, military and sports medicine. We discuss the maturation of individual-specific compensatory reserve or decompensation measures for future wearable sensor systems to effectively manage these hypovolemia problems. The paper then presents areas of future work to allow such technologies to translate from lab settings to use as decision aids for managing hypovolemia. We envision a future that incorporates elements of the compensatory reserve measure with advances in sensing technology and multiple modalities of cardiovascular sensing, additional contextual measures, and advanced noise reduction algorithms into a fully wearable system, creating a robust and physiologically sound approach to manage physical work, fatigue, safety and health issues associated with hypovolemia for workers, warfighters and athletes in austere conditions.
Collapse
|
10
|
Andreozzi E, Gargiulo GD, Esposito D, Bifulco P. A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds. Front Physiol 2021; 12:725716. [PMID: 34867438 PMCID: PMC8637282 DOI: 10.3389/fphys.2021.725716] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 10/19/2021] [Indexed: 01/14/2023] Open
Abstract
The precordial mechanical vibrations generated by cardiac contractions have a rich frequency spectrum. While the lowest frequencies can be palpated, the higher infrasonic frequencies are usually captured by the seismocardiogram (SCG) signal and the audible ones correspond to heart sounds. Forcecardiography (FCG) is a non-invasive technique that measures these vibrations via force sensing resistors (FSR). This study presents a new piezoelectric sensor able to record all heart vibrations simultaneously, as well as a respiration signal. The new sensor was compared to the FSR-based one to assess its suitability for FCG. An electrocardiogram (ECG) lead and a signal from an electro-resistive respiration band (ERB) were synchronously acquired as references on six healthy volunteers (4 males, 2 females) at rest. The raw signals from the piezoelectric and the FSR-based sensors turned out to be very similar. The raw signals were divided into four components: Forcerespirogram (FRG), Low-Frequency FCG (LF-FCG), High-Frequency FCG (HF-FCG) and heart sounds (HS-FCG). A beat-by-beat comparison of FCG and ECG signals was carried out by means of regression, correlation and Bland–Altman analyses, and similarly for respiration signals (FRG and ERB). The results showed that the infrasonic FCG components are strongly related to the cardiac cycle (R2 > 0.999, null bias and Limits of Agreement (LoA) of ± 4.9 ms for HF-FCG; R2 > 0.99, null bias and LoA of ± 26.9 ms for LF-FCG) and the FRG inter-breath intervals are consistent with ERB ones (R2 > 0.99, non-significant bias and LoA of ± 0.46 s). Furthermore, the piezoelectric sensor was tested against an accelerometer and an electronic stethoscope: synchronous acquisitions were performed to quantify the similarity between the signals. ECG-triggered ensemble averages (synchronized with R-peaks) of HF-FCG and SCG showed a correlation greater than 0.81, while those of HS-FCG and PCG scored a correlation greater than 0.85. The piezoelectric sensor demonstrated superior performances as compared to the FSR, providing more accurate, beat-by-beat measurements. This is the first time that a single piezoelectric sensor demonstrated the ability to simultaneously capture respiration, heart sounds, an SCG-like signal (i.e., HF-FCG) and the LF-FCG signal, which may provide information on ventricular emptying and filling events. According to these preliminary results the novel piezoelectric FCG sensor stands as a promising device for accurate, unobtrusive, long-term monitoring of cardiorespiratory functions and paves the way for a wide range of potential applications, both in the research and clinical fields. However, these results should be confirmed by further analyses on a larger cohort of subjects, possibly including also pathological patients.
Collapse
Affiliation(s)
- Emilio Andreozzi
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Naples, Italy
| | - Gaetano D Gargiulo
- School of Engineering, Design and Built Environment, Western Sydney University, Penrith, NSW, Australia
| | - Daniele Esposito
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Naples, Italy
| | - Paolo Bifulco
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Naples, Italy
| |
Collapse
|
11
|
Gazi AH, Sundararaj S, Harrison AB, Gurel NZ, Wittbrodt MT, Alkhalaf M, Soudan M, Levantsevych O, Haffar A, Shah AJ, Vaccarino V, Bremner JD, Inan OT. Transcutaneous Cervical Vagus Nerve Stimulation Inhibits the Reciprocal of the Pulse Transit Time’s Responses to Traumatic Stress in Posttraumatic Stress Disorder. 2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC) 2021; 2021:1444-1447. [PMID: 34891557 PMCID: PMC10114282 DOI: 10.1109/embc46164.2021.9630415] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Research has shown that transcutaneous cervical vagus nerve stimulation (tcVNS) yields downstream changes in peripheral physiology in individuals afflicted with posttraumatic stress disorder (PTSD). While the cardiovascular effects of tcVNS have been studied broadly in prior work, the specific effects of tcVNS on the reciprocal of the pulse transit time (1/PTT) remain unknown. By quantifying detectable effects, tcVNS can be further evaluated as a counterbalance to sympathetic hyperactivity during distress - specifically, we hypothesized that tcVNS would inhibit 1/PTT responses to traumatic stress. To investigate this, the electrocardiogram (ECG), photoplethysmogram (PPG), and seismocardiogram (SCG), were simultaneously measured from 24 human subjects suffering from PTSD. Implementing state-of-the-art signal quality assessment algorithms, relative changes in the pulse arrival time (PAT) and the pre-ejection period (PEP) were estimated solely from signal segments of sufficient quality. Thereby computing relative changes in 1/PTT, we find that tcVNS results in reduced 1/PTT responses to traumatic stress and the first minute of stimulation, compared to a sham control (corrected p < 0.05). This suggests that tcVNS induces inhibitory effects on blood pressure (BP) and/or vasoconstriction, given the established relationship between 1/PTT and these parameters.Clinical Relevance- Relative changes in 1/PTT are induced by varying vasomotor tone and/or BP - it has therefore piqued considerable interest as a potential surrogate of continuous BP. Studying its responses to tcVNS thus furthers understanding of tcVNS-induced cardiovascular modulation. The positive effects detailed herein suggest a potential role for tcVNS in the long-term management of PTSD.
Collapse
|
12
|
A Comprehensive Review on Seismocardiogram: Current Advancements on Acquisition, Annotation, and Applications. MATHEMATICS 2021. [DOI: 10.3390/math9182243] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In recent years, cardiovascular diseases are on the rise, and they entail enormous health burdens on global economies. Cardiac vibrations yield a wide and rich spectrum of essential information regarding the functioning of the heart, and thus it is necessary to take advantage of this data to better monitor cardiac health by way of prevention in early stages. Specifically, seismocardiography (SCG) is a noninvasive technique that can record cardiac vibrations by using new cutting-edge devices as accelerometers. Therefore, providing new and reliable data regarding advancements in the field of SCG, i.e., new devices and tools, is necessary to outperform the current understanding of the State-of-the-Art (SoTA). This paper reviews the SoTA on SCG and concentrates on three critical aspects of the SCG approach, i.e., on the acquisition, annotation, and its current applications. Moreover, this comprehensive overview also presents a detailed summary of recent advancements in SCG, such as the adoption of new techniques based on the artificial intelligence field, e.g., machine learning, deep learning, artificial neural networks, and fuzzy logic. Finally, a discussion on the open issues and future investigations regarding the topic is included.
Collapse
|
13
|
Lin DJ, Kimball JP, Zia J, Ganti VG, Inan OT. Reducing the Impact of External Vibrations on Fiducial Point Detection in Seismocardiogram Signals. IEEE Trans Biomed Eng 2021; 69:176-185. [PMID: 34161234 DOI: 10.1109/tbme.2021.3090376] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE Wearable systems that enable continuous non-invasive monitoring of hemodynamic parameters can aid in cardiac health evaluation in non-hospital settings. The seismocardiogram (SCG) is a non-invasively acquired cardiovascular biosignal for which timings of fiducial points, like aortic valve opening (AO) and aortic valve closing (AC), can enable estimation of key hemodynamic parameters. However, SCG is susceptible to motion artifacts, making accurate estimation of these points difficult when corrupted by high-g or in-band vibration artifacts. In this paper, a novel denoising pipeline is proposed that removes vehicle-vibration artifacts from corrupted SCG beats for accurate fiducial point detection. METHODS The noisy SCG signal is decomposed with ensemble empirical mode decomposition (EEMD). Corrupted segments of the decomposed signal are then identified and removed using the quasi-periodicity of the SCG. Signal quality assessment of the reconstructed SCG beats then removes unreliable beats before feature extraction. The overall approach is validated on simulated vehicle-corrupted SCG generated by adding real subway collected vibration signals onto clean SCG. RESULTS SNR increased by 8.1dB in the AO complex and 11.5dB in the AC complex of the SCG signal. Hemodynamic timing estimation errors reduced by 16.5\% for pre-ejection period (PEP), 67.2\% for left ventricular ejection time (LVET), and 57.7\% for PEP/LVET---a feature previously determined in prior work to be of great importance for assessing blood volume status during hemorrhage. CONCLUSION These findings suggest that usable SCG signals can be recovered from vehicle-corrupted SCG signals using the presented denoising framework, allowing for accurate hemodynamic timing estimation. SIGNIFICANCE Reliable hemodynamic estimates from vehicle-corrupted SCG signals will enable the adoption of the SCG in outside-of-hospital settings.
Collapse
|
14
|
Richardson KL, Gharehbaghi S, Ozmen GC, Safaei MM, Inan OT. Quantifying Signal Quality for Joint Acoustic Emissions Using Graph-Based Spectral Embedding. IEEE SENSORS JOURNAL 2021; 21:13676-13684. [PMID: 34658673 PMCID: PMC8516116 DOI: 10.1109/jsen.2021.3071664] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
We present a new method for quantifying signal quality of joint acoustic emissions (JAEs) from the knee during unloaded flexion/extension (F/E) exercises. For ten F/E cycles, JAEs were recorded, in a clinical setting, from 34 healthy knees and 13 with a meniscus tear (n=24 subjects). The recordings were first segmented by F/E cycle and described using time and frequency domain features. Using these features, a symmetric k-nearest neighbor graph was created and described using a spectral embedding. We show how the underlying community structure of JAEs was comparable across joint health levels and was highly affected by artifacts. Each F/E cycle was scored by its distance from a diverse set of manually annotated, clean templates and removed if above the artifact threshold. We validate this methodology by showing an improvement in the distinction between the JAEs of healthy and injured knees. Graph community factor (GCF) was used to detect the number of communities in each recording and describe the heterogeneity of JAEs from each knee. Before artifact removal, there was no significant difference between the healthy and injured groups due to the impact of artifacts on the community construction. Following implementation of artifact removal, we observed improvement in knee health classification. The GCF value for the meniscus tear group was significantly higher than the healthy group (p<0.01). With more JAE recordings being taken in the clinic and at home, this paper addresses the need for a robust artifact removal method which is necessary for an accurate description of joint health.
Collapse
Affiliation(s)
- Kristine L Richardson
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA
| | - Sevda Gharehbaghi
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA
| | - Goktug C Ozmen
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA
| | - Mohsen M Safaei
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA
| | - Omer T Inan
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA
| |
Collapse
|
15
|
Ganti VG, Carek AM, Nevius BN, Heller JA, Etemadi M, Inan OT. Wearable Cuff-Less Blood Pressure Estimation at Home via Pulse Transit Time. IEEE J Biomed Health Inform 2021; 25:1926-1937. [PMID: 32881697 PMCID: PMC8221527 DOI: 10.1109/jbhi.2020.3021532] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE We developed a wearable watch-based device to provide noninvasive, cuff-less blood pressure (BP) estimation in an at-home setting. METHODS The watch measures single-lead electrocardiogram (ECG), tri-axial seismocardiogram (SCG), and multi-wavelength photoplethysmogram (PPG) signals to compute the pulse transit time (PTT), allowing for BP estimation. We sent our custom watch device and an oscillometric BP cuff home with 21 healthy subjects, and captured the natural variability in BP over the course of a 24-hour period. RESULTS After calibration, our Pearson correlation coefficient (PCC) of 0.69 and root-mean-square-error (RMSE) of 2.72 mmHg suggest that noninvasive PTT measurements correlate with around-the-clock BP. Using a novel two-point calibration method, we achieved a RMSE of 3.86 mmHg. We further demonstrated the potential of a semi-globalized adaptive model to reduce calibration requirements. CONCLUSION This is, to the best of our knowledge, the first time that BP has been comprehensively estimated noninvasively using PTT in an at-home setting. We showed a more convenient method for obtaining ambulatory BP than through the use of the standard oscillometric cuff. We presented new calibration methods for BP estimation using fewer calibration points that are more practical for a real-world scenario. SIGNIFICANCE A custom watch (SeismoWatch) capable of taking multiple BP measurements enables reliable remote monitoring of daily BP and paves the way towards convenient hypertension screening and management, which can potentially reduce hospitalizations and improve quality of life.
Collapse
|
16
|
Semiz B, Carek AM, Johnson JC, Ahmad S, Heller JA, Vicente FG, Caron S, Hogue CW, Etemadi M, Inan OT. Non-Invasive Wearable Patch Utilizing Seismocardiography for Peri-Operative Use in Surgical Patients. IEEE J Biomed Health Inform 2021; 25:1572-1582. [PMID: 33090962 PMCID: PMC8189504 DOI: 10.1109/jbhi.2020.3032938] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVE Optimizing peri-operative fluid management has been shown to improve patient outcomes and the use of stroke volume (SV) measurement has become an accepted tool to guide fluid therapy. The Transesophageal Doppler (TED) is a validated, minimally invasive device that allows clinical assessment of SV. Unfortunately, the use of the TED is restricted to the intra-operative setting in anesthetized patients and requires constant supervision and periodic adjustment for accurate signal quality. However, post-operative fluid management is also vital for improved outcomes. Currently, there is no device regularly used in clinics that can track patient's SV continuously and non-invasively both during and after surgery. METHODS In this paper, we propose the use of a wearable patch mounted on the mid-sternum, which captures the seismocardiogram (SCG) and electrocardiogram (ECG) signals continuously to predict SV in patients undergoing major surgery. In a study of 12 patients, hemodynamic data was recorded simultaneously using the TED and wearable patch. Signal processing and regression techniques were used to derive SV from the signals (SCG and ECG) captured by the wearable patch and compare it to values obtained by the TED. RESULTS The results showed that the combination of SCG and ECG contains substantial information regarding SV, resulting in a correlation and median absolute error between the predicted and reference SV values of 0.81 and 7.56 mL, respectively. SIGNIFICANCE This work shows promise for the proposed wearable-based methodology to be used as an alternative to TED for continuous patient monitoring and guiding peri-operative fluid management.
Collapse
|
17
|
Convertino VA, Schauer SG, Weitzel EK, Cardin S, Stackle ME, Talley MJ, Sawka MN, Inan OT. Wearable Sensors Incorporating Compensatory Reserve Measurement for Advancing Physiological Monitoring in Critically Injured Trauma Patients. SENSORS (BASEL, SWITZERLAND) 2020; 20:E6413. [PMID: 33182638 PMCID: PMC7697670 DOI: 10.3390/s20226413] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 11/02/2020] [Accepted: 11/04/2020] [Indexed: 12/21/2022]
Abstract
Vital signs historically served as the primary method to triage patients and resources for trauma and emergency care, but have failed to provide clinically-meaningful predictive information about patient clinical status. In this review, a framework is presented that focuses on potential wearable sensor technologies that can harness necessary electronic physiological signal integration with a current state-of-the-art predictive machine-learning algorithm that provides early clinical assessment of hypovolemia status to impact patient outcome. The ability to study the physiology of hemorrhage using a human model of progressive central hypovolemia led to the development of a novel machine-learning algorithm known as the compensatory reserve measurement (CRM). Greater sensitivity, specificity, and diagnostic accuracy to detect hemorrhage and onset of decompensated shock has been demonstrated by the CRM when compared to all standard vital signs and hemodynamic variables. The development of CRM revealed that continuous measurements of changes in arterial waveform features represented the most integrated signal of physiological compensation for conditions of reduced systemic oxygen delivery. In this review, detailed analysis of sensor technologies that include photoplethysmography, tonometry, ultrasound-based blood pressure, and cardiogenic vibration are identified as potential candidates for harnessing arterial waveform analog features required for real-time calculation of CRM. The integration of wearable sensors with the CRM algorithm provides a potentially powerful medical monitoring advancement to save civilian and military lives in emergency medical settings.
Collapse
Affiliation(s)
- Victor A. Convertino
- Battlefield Health & Trauma Center for Human Integrative Physiology, US Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA;
- Uniformed Services University of the Health Sciences, Bethesda, MD 20814, USA;
| | - Steven G. Schauer
- Battlefield Health & Trauma Center for Human Integrative Physiology, US Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA;
- Uniformed Services University of the Health Sciences, Bethesda, MD 20814, USA;
- Brooke Army Medical Center, JBSA Fort Sam Houston, San Antonio, TX 78234, USA
| | - Erik K. Weitzel
- Uniformed Services University of the Health Sciences, Bethesda, MD 20814, USA;
- Brooke Army Medical Center, JBSA Fort Sam Houston, San Antonio, TX 78234, USA
- 59th Medical Wing, JBSA Lackland, San Antonio, TX 78236, USA
| | - Sylvain Cardin
- Navy Medical Research Unit, JBSA Fort Sam Houston, San Antonio, TX 78234, USA;
| | - Mark E. Stackle
- Commander, US Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA;
| | - Michael J. Talley
- Commanding General, US Army Medical Research and Development Command, Fort Detrick, Frederick, MD 21702, USA;
| | - Michael N. Sawka
- Georgia Institute of Technology, Atlanta, GA 30332, USA; (M.N.S.); (O.T.I.)
| | - Omer T. Inan
- Georgia Institute of Technology, Atlanta, GA 30332, USA; (M.N.S.); (O.T.I.)
| |
Collapse
|
18
|
Zia J, Kimball J, Rozell C, Inan OT. Harnessing the Manifold Structure of Cardiomechanical Signals for Physiological Monitoring During Hemorrhage. IEEE Trans Biomed Eng 2020; 68:1759-1767. [PMID: 32749958 DOI: 10.1109/tbme.2020.3014040] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Local oscillation of the chest wall in response to events during the cardiac cycle may be captured using a sensing modality called seismocardiography (SCG), which is commonly used to infer cardiac time intervals (CTIs) such as the pre-ejection period (PEP). An important factor impeding the ubiquitous application of SCG for cardiac monitoring is that morphological variability of the signals makes consistent inference of CTIs a difficult task in the time-domain. The goal of this work is therefore to enable SCG-based physiological monitoring during trauma-induced hemorrhage using signal dynamics rather than morphological features. METHODS We introduce and explore the observation that SCG signals follow a consistent low-dimensional manifold structure during periods of changing PEP induced in a porcine model of trauma injury. Furthermore, we show that the distance traveled along this manifold correlates strongly to changes in PEP ( ∆PEP). RESULTS ∆PEP estimation during hemorrhage was achieved with a median R2 of 92.5% using a rapid manifold approximation method, comparable to an ISOMAP reference standard, which achieved an R2 of 95.3%. CONCLUSION Rapidly approximating the manifold structure of SCG signals allows for physiological inference abstracted from the time-domain, laying the groundwork for robust, morphology-independent processing methods. SIGNIFICANCE Ultimately, this work represents an important advancement in SCG processing, enabling future clinical tools for trauma injury management.
Collapse
|
19
|
Zia J, Kimball J, Hersek S, Inan OT. Modeling Consistent Dynamics of Cardiogenic Vibrations in Low-Dimensional Subspace. IEEE J Biomed Health Inform 2020; 24:1887-1898. [PMID: 32175880 PMCID: PMC7394000 DOI: 10.1109/jbhi.2020.2980979] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
The seismocardiogram (SCG) measures the movement of the chest wall in response to underlying cardiovascular events. Though this signal contains clinically-relevant information, its morphology is both patient-specific and highly transient. In light of recent work suggesting the existence of population-level patterns in SCG signals, the objective of this study is to develop a method which harnesses these patterns to enable robust signal processing despite morphological variability. Specifically, we introduce seismocardiogram generative factor encoding (SGFE), which models the SCG waveform as a stochastic sample from a low-dimensional subspace defined by a unified set of generative factors. We then demonstrate that during dynamic processes such as exercise-recovery, learned factors correlate strongly with known generative factors including aortic opening (AO) and closing (AC), following consistent trajectories in subspace despite morphological differences. Furthermore, we found that changes in sensor location affect the perceived underlying dynamic process in predictable ways, thereby enabling algorithmic compensation for sensor misplacement during generative factor inference. Mapping these trajectories to AO and AC yielded R2 values from 0.81-0.90 for AO and 0.72-0.83 for AC respectively across five sensor positions. Identification of consistent behavior of SCG signals in low dimensions corroborates the existence of population-level patterns in these signals; SGFE may also serve as a harbinger for processing methods that are abstracted from the time domain, which may ultimately improve the feasibility of SCG utilization in ambulatory and outpatient settings.
Collapse
|