Landry V, Semsar-Kazerooni K, Chen T, Gurberg J, Nguyen LHP, Constantin E. Diagnostic accuracy of portable sleep monitors in pediatric sleep apnea: A systematic review. Sleep Med Rev 2024; 78:101991. [PMID: 39173472 DOI: 10.1016/j.smrv.2024.101991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 05/01/2024] [Accepted: 08/05/2024] [Indexed: 08/24/2024]
Abstract
In recent years, a plethora of new type III and IV portable sleep monitors (PSM) have been developed, although evidence regarding their diagnostic accuracy for use in children remains heterogeneous. This study systematically reviews the literature addressing the diagnostic accuracies of type III and IV PSM for pediatric sleep apnea. Publications indexed in Medline, Embase, or Web of Science were reviewed using the PRISMA framework. Of 1054 studies, 62 fulfilled the inclusion criteria. Of the studies evaluating oximetry-based type IV PSM, one (6.25 %) demonstrated a balanced set of high (≥80 %) sensitivities and specificities for the diagnosis of any pediatric sleep apnea, while five studies (27.8 %) showed similar accuracies for moderate-to-severe sleep apnea. For non-oximetry-based type IV PSM, two studies (40 %) reported a balanced set of high diagnostic accuracies for moderate-to-severe sleep apnea. Type III PSM repeatedly demonstrated higher diagnostic accuracies, with six studies (66.7 %) reporting a balanced set of high diagnostic accuracies for moderate-to-severe sleep apnea. This review highlights the potential of type III PSM to detect moderate-to-severe pediatric sleep apnea, although current evidence is limited to support the stand-alone use of type IV PSM for the diagnosis of sleep apnea in most children.
Collapse
Affiliation(s)
- Vivianne Landry
- Division of Otolaryngology-Head and Neck Surgery, University of Montreal, Montreal, QC, Canada
| | | | - Tanya Chen
- Department of Otolaryngology-Head and Neck Surgery, University of Toronto, Toronto, ON, Canada
| | - Joshua Gurberg
- Department of Otolaryngology-Head and Neck Surgery, McGill University, Montreal, QC, Canada
| | - Lily H P Nguyen
- Department of Otolaryngology-Head and Neck Surgery, McGill University, Montreal, QC, Canada
| | - Evelyn Constantin
- Department of Pediatrics, Pediatric Sleep Medicine, McGill University, Montreal, QC, Canada.
| |
Collapse
|
2
|
Yang S, van Twist E, van Heesch GG, de Jonge RC, Louter M, Tasker RC, Mathijssen IM, Joosten KF. Severe obstructive sleep apnea in children with syndromic craniosynostosis: analysis of pulse transit time. J Clin Sleep Med 2024; 20:1233-1240. [PMID: 38456822 PMCID: PMC11294133 DOI: 10.5664/jcsm.11112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Revised: 02/27/2024] [Accepted: 02/28/2024] [Indexed: 03/09/2024]
Abstract
STUDY OBJECTIVES We examined the association between pulse transit time (PTT) and obstructive sleep apnea (OSA) in children with syndromic craniosynostosis (SCS), where OSA is a common problem and may cause cardiorespiratory disturbance. METHODS A retrospective study of children (age < 18 years) with SCS and moderate-to-severe OSA (ie, obstructive apnea-hypopnea index ≥ 5) or no OSA (obstructive apnea-hypopnea index < 1) who underwent overnight polysomnography. Children without SCS and normal polysomnography were included as controls. Reference intervals for PTT were computed by nonparametric bootstrap analysis. Based on reference intervals of controls, the sensitivity and specificity of PTT to detect OSA were determined. In a linear mixed model, the explanatory variables assessed were sex, age, sleep stage, and time after obstructive events. RESULTS In all 68 included children (19 with SCS with OSA, 30 with SCS without OSA, 19 controls), obstructive events occurred throughout all sleep stages, most prominently during rapid eye movement (REM) sleep and non-REM sleep stages N1 and N2, with evident PTT changes. The greatest reductions were observed 4-8 seconds after an event (P < .05). In SCS with OSA, PTT reference intervals were lower during all sleep stages compared with SCS without OSA. The highest sensitivity was observed during N1 (55.5%), and the highest specificity during REM sleep (76.5%). The lowest PTT values were identified during N1. CONCLUSIONS Obstructive events occur throughout all sleep stages with transient reductions in PTT. However, PTT as a variable for OSA detection is limited by its sensitivity and specificity. CITATION Yang S, van Twist E, van Heesch GGM, et al. Severe obstructive sleep apnea in children with syndromic craniosynostosis: analysis of pulse transit time. J Clin Sleep Med. 2024;20(8):1233-1240.
Collapse
Affiliation(s)
- Sumin Yang
- Department of Plastic and Reconstructive Surgery and Hand Surgery, Erasmus MC Sophia Children’s Hospital, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Eris van Twist
- Department of Neonatal and Pediatric Intensive Care, Division of Pediatric Intensive Care, Erasmus MC Sophia Children’s Hospital, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Gwen G.M. van Heesch
- Department of Neonatal and Pediatric Intensive Care, Division of Pediatric Intensive Care, Erasmus MC Sophia Children’s Hospital, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Rogier C.J. de Jonge
- Department of Neonatal and Pediatric Intensive Care, Division of Pediatric Intensive Care, Erasmus MC Sophia Children’s Hospital, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Maartje Louter
- Department of Neurology, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Robert C. Tasker
- Department of Anesthesiology, Critical Care, and Pain Medicine, Boston Children’s Hospital, Boston, Massachusetts
| | - Irene M.J. Mathijssen
- Department of Plastic and Reconstructive Surgery and Hand Surgery, Erasmus MC Sophia Children’s Hospital, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Koen F.M. Joosten
- Department of Neonatal and Pediatric Intensive Care, Division of Pediatric Intensive Care, Erasmus MC Sophia Children’s Hospital, Erasmus Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
3
|
García-Vicente C, Gutiérrez-Tobal GC, Jiménez-García J, Martín-Montero A, Gozal D, Hornero R. ECG-based convolutional neural network in pediatric obstructive sleep apnea diagnosis. Comput Biol Med 2023; 167:107628. [PMID: 37918264 DOI: 10.1016/j.compbiomed.2023.107628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 09/28/2023] [Accepted: 10/23/2023] [Indexed: 11/04/2023]
Abstract
Obstructive sleep apnea (OSA) is a prevalent respiratory condition in children and is characterized by partial or complete obstruction of the upper airway during sleep. The respiratory events in OSA induce transient alterations of the cardiovascular system that ultimately can lead to increased cardiovascular risk in affected children. Therefore, a timely and accurate diagnosis is of utmost importance. However, polysomnography (PSG), the standard diagnostic test for pediatric OSA, is complex, uncomfortable, costly, and relatively inaccessible, particularly in low-resource environments, thereby resulting in substantial underdiagnosis. Here, we propose a novel deep-learning approach to simplify the diagnosis of pediatric OSA using raw electrocardiogram tracing (ECG). Specifically, a new convolutional neural network (CNN)-based regression model was implemented to automatically predict pediatric OSA by estimating its severity based on the apnea-hypopnea index (AHI) and deriving 4 OSA severity categories. For this purpose, overnight ECGs from 1,610 PSG recordings obtained from the Childhood Adenotonsillectomy Trial (CHAT) database were used. The database was randomly divided into approximately 60%, 20%, and 20% for training, validation, and testing, respectively. The diagnostic performance of the proposed CNN model largely outperformed the most accurate previous algorithms that relied on ECG-derived features (4-class Cohen's kappa coefficient of 0.373 versus 0.166). Specifically, for AHI cutoff values of 1, 5, and 10 events/hour, the binary classification achieved sensitivities of 84.19%, 76.67%, and 53.66%; specificities of 46.15%, 91.39%, and 98.06%; and accuracies of 75.92%, 86.96%, and 91.97%, respectively. Therefore, pediatric OSA can be readily identified by our proposed CNN model, which provides a simpler, faster, and more accessible diagnostic test that can be implemented in clinical practice.
Collapse
Affiliation(s)
| | - Gonzalo C Gutiérrez-Tobal
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain
| | - Jorge Jiménez-García
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain
| | - Adrián Martín-Montero
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain
| | - David Gozal
- Office of The Dean, Joan C. Edwards School of Medicine, Marshall University, 1600 Medical Center Dr, Huntington, WV, 25701, USA
| | - Roberto Hornero
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain
| |
Collapse
|
4
|
Charlton PH, Allen J, Bailón R, Baker S, Behar JA, Chen F, Clifford GD, Clifton DA, Davies HJ, Ding C, Ding X, Dunn J, Elgendi M, Ferdoushi M, Franklin D, Gil E, Hassan MF, Hernesniemi J, Hu X, Ji N, Khan Y, Kontaxis S, Korhonen I, Kyriacou PA, Laguna P, Lázaro J, Lee C, Levy J, Li Y, Liu C, Liu J, Lu L, Mandic DP, Marozas V, Mejía-Mejía E, Mukkamala R, Nitzan M, Pereira T, Poon CCY, Ramella-Roman JC, Saarinen H, Shandhi MMH, Shin H, Stansby G, Tamura T, Vehkaoja A, Wang WK, Zhang YT, Zhao N, Zheng D, Zhu T. The 2023 wearable photoplethysmography roadmap. Physiol Meas 2023; 44:111001. [PMID: 37494945 PMCID: PMC10686289 DOI: 10.1088/1361-6579/acead2] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 04/04/2023] [Accepted: 07/26/2023] [Indexed: 07/28/2023]
Abstract
Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.
Collapse
Affiliation(s)
- Peter H Charlton
- Department of Public Health and Primary Care, University of Cambridge, Cambridge, CB1 8RN, United Kingdom
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, United Kingdom
| | - John Allen
- Research Centre for Intelligent Healthcare, Coventry University, Coventry, CV1 5RW, United Kingdom
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, NE2 4HH, United Kingdom
| | - Raquel Bailón
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Stephanie Baker
- College of Science and Engineering, James Cook University, Cairns, 4878 Queensland, Australia
| | - Joachim A Behar
- Faculty of Biomedical Engineering, Technion Israel Institute of Technology, Haifa, 3200003, Israel
| | - Fei Chen
- Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen, 518055 Guandong, People’s Republic of China
| | - Gari D Clifford
- Department of Biomedical Informatics, Emory University, Atlanta, GA 30322, United States of America
- Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States of America
| | - David A Clifton
- Department of Engineering Science, University of Oxford, Oxford, OX3 7DQ, United Kingdom
| | - Harry J Davies
- Department of Electrical and Electronic Engineering, Imperial College London, London, SW7 2AZ, United Kingdom
| | - Cheng Ding
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States of America
- Department of Biomedical Engineering, Emory University, Atlanta, GA 30322, United States of America
| | - Xiaorong Ding
- School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, 611731, People’s Republic of China
| | - Jessilyn Dunn
- Department of Biomedical Engineering, Duke University, Durham, NC 27708-0187, United States of America
- Department of Biostatistics & Bioinformatics, Duke University, Durham, NC 27708-0187, United States of America
- Duke Clinical Research Institute, Durham, NC 27705-3976, United States of America
| | - Mohamed Elgendi
- Biomedical and Mobile Health Technology Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, 8008, Switzerland
| | - Munia Ferdoushi
- Department of Electrical and Computer Engineering, University of Southern California, 90089, Los Angeles, California, United States of America
- The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, United States of America
| | - Daniel Franklin
- Institute of Biomedical Engineering, Translational Biology & Engineering Program, Ted Rogers Centre for Heart Research, University of Toronto, Toronto, M5G 1M1, Canada
| | - Eduardo Gil
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Md Farhad Hassan
- Department of Electrical and Computer Engineering, University of Southern California, 90089, Los Angeles, California, United States of America
- The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, United States of America
| | - Jussi Hernesniemi
- Finnish Cardiovascular Research Center Tampere, Faculty of Medicine and Health Technology, Tampere University, Tampere, 33720, Finland
- Tampere Heart Hospital, Wellbeing Services County of Pirkanmaa, Tampere, 33520, Finland
| | - Xiao Hu
- Nell Hodgson Woodruff School of Nursing, Emory University, Atlanta, 30322, Georgia, United States of America
- Department of Biomedical Informatics, School of Medicine, Emory University, Atlanta, 30322, Georgia, United States of America
- Department of Computer Sciences, College of Arts and Sciences, Emory University, Atlanta, GA 30322, United States of America
| | - Nan Ji
- Hong Kong Center for Cerebrocardiovascular Health Engineering (COCHE), Hong Kong Science and Technology Park, Hong Kong, 999077, People’s Republic of China
| | - Yasser Khan
- Department of Electrical and Computer Engineering, University of Southern California, 90089, Los Angeles, California, United States of America
- The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, United States of America
| | - Spyridon Kontaxis
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Ilkka Korhonen
- Finnish Cardiovascular Research Center Tampere, Faculty of Medicine and Health Technology, Tampere University, Tampere, 33720, Finland
| | - Panicos A Kyriacou
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, United Kingdom
| | - Pablo Laguna
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Jesús Lázaro
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Chungkeun Lee
- Digital Health Devices Division, Medical Device Evaluation Department, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Cheongju, 28159, Republic of Korea
| | - Jeremy Levy
- Faculty of Biomedical Engineering, Technion Israel Institute of Technology, Haifa, 3200003, Israel
- Faculty of Electrical and Computer Engineering, Technion Institute of Technology, Haifa, 3200003, Israel
| | - Yumin Li
- State Key Laboratory of Bioelectronics, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, People’s Republic of China
| | - Chengyu Liu
- State Key Laboratory of Bioelectronics, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, People’s Republic of China
| | - Jing Liu
- Analog Devices Inc, San Jose, CA 95124, United States of America
| | - Lei Lu
- Department of Engineering Science, University of Oxford, Oxford, OX3 7DQ, United Kingdom
| | - Danilo P Mandic
- Department of Electrical and Electronic Engineering, Imperial College London, London, SW7 2AZ, United Kingdom
| | - Vaidotas Marozas
- Department of Electronics Engineering, Kaunas University of Technology, 44249 Kaunas, Lithuania
- Biomedical Engineering Institute, Kaunas University of Technology, 44249 Kaunas, Lithuania
| | - Elisa Mejía-Mejía
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, United Kingdom
| | - Ramakrishna Mukkamala
- Department of Bioengineering and Department of Anesthesiology and Perioperative Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, United States of America
| | - Meir Nitzan
- Department of Physics/Electro-Optic Engineering, Lev Academic Center, 91160 Jerusalem, Israel
| | - Tania Pereira
- INESC TEC—Institute for Systems and Computer Engineering, Technology and Science, Porto, 4200-465, Portugal
- Faculty of Engineering, University of Porto, Porto, 4200-465, Portugal
| | | | - Jessica C Ramella-Roman
- Department of Biomedical Engineering and Herbert Wertheim College of Medicine, Florida International University, Miami, FL 33174, United States of America
| | - Harri Saarinen
- Tampere Heart Hospital, Wellbeing Services County of Pirkanmaa, Tampere, 33520, Finland
| | - Md Mobashir Hasan Shandhi
- Department of Biomedical Engineering, Duke University, Durham, NC 27708-0187, United States of America
| | - Hangsik Shin
- Department of Digital Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Gerard Stansby
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, NE2 4HH, United Kingdom
- Northern Vascular Centre, Freeman Hospital, Newcastle upon Tyne, NE7 7DN, United Kingdom
| | - Toshiyo Tamura
- Future Robotics Organization, Waseda University, Tokyo, 1698050, Japan
| | - Antti Vehkaoja
- Finnish Cardiovascular Research Center Tampere, Faculty of Medicine and Health Technology, Tampere University, Tampere, 33720, Finland
- PulseOn Ltd, Espoo, 02150, Finland
| | - Will Ke Wang
- Department of Biomedical Engineering, Duke University, Durham, NC 27708-0187, United States of America
| | - Yuan-Ting Zhang
- Hong Kong Center for Cerebrocardiovascular Health Engineering (COCHE), Hong Kong Science and Technology Park, Hong Kong, 999077, People’s Republic of China
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, 999077, People’s Republic of China
| | - Ni Zhao
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong
| | - Dingchang Zheng
- Research Centre for Intelligent Healthcare, Coventry University, Coventry, CV1 5RW, United Kingdom
| | - Tingting Zhu
- Department of Engineering Science, University of Oxford, Oxford, OX3 7DQ, United Kingdom
| |
Collapse
|
5
|
Martín-Montero A, Armañac-Julián P, Gil E, Kheirandish-Gozal L, Álvarez D, Lázaro J, Bailón R, Gozal D, Laguna P, Hornero R, Gutiérrez-Tobal GC. Pediatric sleep apnea: Characterization of apneic events and sleep stages using heart rate variability. Comput Biol Med 2023; 154:106549. [PMID: 36706566 DOI: 10.1016/j.compbiomed.2023.106549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 12/19/2022] [Accepted: 01/11/2023] [Indexed: 01/16/2023]
Abstract
Heart rate variability (HRV) is modulated by sleep stages and apneic events. Previous studies in children compared classical HRV parameters during sleep stages between obstructive sleep apnea (OSA) and controls. However, HRV-based characterization incorporating both sleep stages and apneic events has not been conducted. Furthermore, recently proposed novel HRV OSA-specific parameters have not been evaluated. Therefore, the aim of this study was to characterize and compare classic and pediatric OSA-specific HRV parameters while including both sleep stages and apneic events. A total of 1610 electrocardiograms from the Childhood Adenotonsillectomy Trial (CHAT) database were split into 10-min segments to extract HRV parameters. Segments were characterized and grouped by sleep stage (wake, W; non-rapid eye movement, NREMS; and REMS) and presence of apneic events (under 1 apneic event per segment, e/s; 1-5 e/s; 5-10 e/s; and over 10 e/s). NREMS showed significant changes in HRV parameters as apneic event frequency increased, which were less marked in REMS. In both NREMS and REMS, power in BW2, a pediatric OSA-specific frequency domain, allowed for the optimal differentiation among segments. Moreover, in the absence of apneic events, another defined band, BWRes, resulted in best differentiation between sleep stages. The clinical usefulness of segment-based HRV characterization was then confirmed by two ensemble-learning models aimed at estimating apnea-hypopnea index and classifying sleep stages, respectively. We surmise that basal sympathetic activity during REMS may mask apneic events-induced sympathetic excitation, thus highlighting the importance of incorporating sleep stages as well as apneic events when evaluating HRV in pediatric OSA.
Collapse
Affiliation(s)
- Adrián Martín-Montero
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain.
| | - Pablo Armañac-Julián
- CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain; Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Institute of Engineering Research (I3A), IIS Aragón, University of Zaragoza, Zaragoza, Spain
| | - Eduardo Gil
- CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain; Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Institute of Engineering Research (I3A), IIS Aragón, University of Zaragoza, Zaragoza, Spain
| | - Leila Kheirandish-Gozal
- Department of Child Health, The University of Missouri School of Medicine, Columbia, MO, USA
| | - Daniel Álvarez
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain
| | - Jesús Lázaro
- CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain; Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Institute of Engineering Research (I3A), IIS Aragón, University of Zaragoza, Zaragoza, Spain
| | - Raquel Bailón
- CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain; Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Institute of Engineering Research (I3A), IIS Aragón, University of Zaragoza, Zaragoza, Spain
| | - David Gozal
- Department of Child Health, The University of Missouri School of Medicine, Columbia, MO, USA
| | - Pablo Laguna
- CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain; Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Institute of Engineering Research (I3A), IIS Aragón, University of Zaragoza, Zaragoza, Spain
| | - Roberto Hornero
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain
| | - Gonzalo C Gutiérrez-Tobal
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain
| |
Collapse
|
6
|
Monegro A, Gawri K. Heart rate variability in children with sleep disordered breathing. PROGRESS IN PEDIATRIC CARDIOLOGY 2023. [DOI: 10.1016/j.ppedcard.2023.101620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
|
7
|
Gutiérrez-Tobal GC, Álvarez D, Kheirandish-Gozal L, Del Campo F, Gozal D, Hornero R. Reliability of machine learning to diagnose pediatric obstructive sleep apnea: Systematic review and meta-analysis. Pediatr Pulmonol 2022; 57:1931-1943. [PMID: 33856128 DOI: 10.1002/ppul.25423] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 04/07/2021] [Accepted: 04/10/2021] [Indexed: 12/27/2022]
Abstract
BACKGROUND Machine-learning approaches have enabled promising results in efforts to simplify the diagnosis of pediatric obstructive sleep apnea (OSA). A comprehensive review and analysis of such studies increase the confidence level of practitioners and healthcare providers in the implementation of these methodologies in clinical practice. OBJECTIVE To assess the reliability of machine-learning-based methods to detect pediatric OSA. DATA SOURCES Two researchers conducted an electronic search on the Web of Science and Scopus using term, and studies were reviewed along with their bibliographic references. ELIGIBILITY CRITERIA Articles or reviews (Year 2000 onwards) that applied machine learning to detect pediatric OSA; reported data included information enabling derivation of true positive, false negative, true negative, and false positive cases; polysomnography served as diagnostic standard. APPRAISAL AND SYNTHESIS METHODS Pooled sensitivities and specificities were computed for three apnea-hypopnea index (AHI) thresholds: 1 event/hour (e/h), 5 e/h, and 10 e/h. Random-effect models were assumed. Summary receiver-operating characteristics (SROC) analyses were also conducted. Heterogeneity (I 2 ) was evaluated, and publication bias was corrected (trim and fill). RESULTS Nineteen studies were finally retained, involving 4767 different pediatric sleep studies. Machine learning improved diagnostic performance as OSA severity criteria increased reaching optimal values for AHI = 10 e/h (0.652 sensitivity; 0.931 specificity; and 0.940 area under the SROC curve). Publication bias correction had minor effect on summary statistics, but high heterogeneity was observed among the studies.
Collapse
Affiliation(s)
- Gonzalo C Gutiérrez-Tobal
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain.,Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, (CIBER-BBN), Zaragoza, Spain
| | - Daniel Álvarez
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain.,Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, (CIBER-BBN), Zaragoza, Spain.,Department of Pneumology, Río Hortega University Hospital, Valladolid, Spain
| | - Leila Kheirandish-Gozal
- Department of Child Health, Child Health Research Institute, The University of Missouri School of Medicine, Columbia, Missouri, USA
| | - Félix Del Campo
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain.,Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, (CIBER-BBN), Zaragoza, Spain.,Department of Pneumology, Río Hortega University Hospital, Valladolid, Spain
| | - David Gozal
- Department of Child Health, Child Health Research Institute, The University of Missouri School of Medicine, Columbia, Missouri, USA
| | - Roberto Hornero
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain.,Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, (CIBER-BBN), Zaragoza, Spain.,Department of Pneumology, Río Hortega University Hospital, Valladolid, Spain
| |
Collapse
|
8
|
Wang Y, Haick H, Guo S, Wang C, Lee S, Yokota T, Someya T. Skin bioelectronics towards long-term, continuous health monitoring. Chem Soc Rev 2022; 51:3759-3793. [PMID: 35420617 DOI: 10.1039/d2cs00207h] [Citation(s) in RCA: 76] [Impact Index Per Article: 38.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Skin bioelectronics are considered as an ideal platform for personalised healthcare because of their unique characteristics, such as thinness, light weight, good biocompatibility, excellent mechanical robustness, and great skin conformability. Recent advances in skin-interfaced bioelectronics have promoted various applications in healthcare and precision medicine. Particularly, skin bioelectronics for long-term, continuous health monitoring offer powerful analysis of a broad spectrum of health statuses, providing a route to early disease diagnosis and treatment. In this review, we discuss (1) representative healthcare sensing devices, (2) material and structure selection, device properties, and wireless technologies of skin bioelectronics towards long-term, continuous health monitoring, (3) healthcare applications: acquisition and analysis of electrophysiological, biophysical, and biochemical signals, and comprehensive monitoring, and (4) rational guidelines for the design of future skin bioelectronics for long-term, continuous health monitoring. Long-term, continuous health monitoring of advanced skin bioelectronics will open unprecedented opportunities for timely disease prevention, screening, diagnosis, and treatment, demonstrating great promise to revolutionise traditional medical practices.
Collapse
Affiliation(s)
- Yan Wang
- Department of Chemical Engineering, Guangdong Technion-Israel Institute of Technology (GTIIT), Shantou, Guangdong 515063, China.,Technion-Israel Institute of Technology (IIT), Haifa 32000, Israel.,Department of Electrical Engineering and Information Systems, The University of Tokyo, Tokyo 113-8656, Japan. .,Guangdong Provincial Key Laboratory of Materials and Technologies for Energy Conversion, Guangdong Technion - Israel Institute of Technology, Shantou, Guangdong 515063, China
| | - Hossam Haick
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa 3200003, Israel
| | - Shuyang Guo
- Department of Electrical Engineering and Information Systems, The University of Tokyo, Tokyo 113-8656, Japan.
| | - Chunya Wang
- Department of Electrical Engineering and Information Systems, The University of Tokyo, Tokyo 113-8656, Japan.
| | - Sunghoon Lee
- Department of Electrical Engineering and Information Systems, The University of Tokyo, Tokyo 113-8656, Japan.
| | - Tomoyuki Yokota
- Department of Electrical Engineering and Information Systems, The University of Tokyo, Tokyo 113-8656, Japan.
| | - Takao Someya
- Department of Electrical Engineering and Information Systems, The University of Tokyo, Tokyo 113-8656, Japan.
| |
Collapse
|
9
|
Hoppenbrouwer XLR, Rollinson AU, Dunsmuir D, Ansermino JM, Dumont G, Oude Nijeweme-d'Hollosy W, Veltink P, Garde A. Night to night variability of pulse oximetry features in children at home and at the hospital. Physiol Meas 2021; 42. [PMID: 34713819 DOI: 10.1088/1361-6579/ac278e] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Accepted: 09/16/2021] [Indexed: 12/22/2022]
Abstract
Objective. Investigation of the night-to-night (NtN) variability of pulse oximetry features in children with suspicion of Sleep Apnea.Approach. Following ethics approval and informed consent, 75 children referred to British Columbia Children's Hospital for overnight PSG were recorded on three consecutive nights, including one at the hospital simultaneously with polysomnography and 2 nights at home. During all three nights, a smartphone-based pulse oximeter sensor was used to record overnight pulse oximetry (SpO2 and photoplethysmogram). Features characterizing SpO2 dynamics and heart rate were derived. The NtN variability of these features over the three different nights was investigated using linear mixed models.Main results. Overall most pulse oximetry features (e.g. the oxygen desaturation index) showed no NtN variability. One of the exceptions is for the signal quality, which was significantly lower during at home measurements compared to measurements in the hospital.Significance. At home pulse oximetry screening shows an increasing predictive value to investigate obstructive sleep apnea (OSA) severity. Hospital recordings affect subjects normal sleep and OSA severity and recordings may vary between nights at home. Before establishing the role of home monitoring as a diagnostic test for OSA, we must first determine their NtN variability. Most pulse oximetry features showed no significant NtN variability and could therefore be used in future at-home testing to create a reliable and consistent OSA screening tool. A single night recording at home should be able to characterize pulse oximetry features in children.
Collapse
Affiliation(s)
- Xenia L R Hoppenbrouwer
- Biomedical Signals and Systems group, Faculty of Electrical Engineering, Mathematics & Computer Science, University of Twente, Enschede, The Netherlands
| | - Aryannah U Rollinson
- The Department of Anesthesiology, Pharmacology & Therapeutics, The University of British Columbia, Vancouver, British Columbia, Canada
| | - Dustin Dunsmuir
- The Department of Anesthesiology, Pharmacology & Therapeutics, The University of British Columbia, Vancouver, British Columbia, Canada
| | - J Mark Ansermino
- The Department of Anesthesiology, Pharmacology & Therapeutics, The University of British Columbia, Vancouver, British Columbia, Canada
| | - Guy Dumont
- The Department of Electrical & Computer Engineering, The University of British Columbia, Vancouver, British Columbia, Canada
| | - Wendy Oude Nijeweme-d'Hollosy
- Biomedical Signals and Systems group, Faculty of Electrical Engineering, Mathematics & Computer Science, University of Twente, Enschede, The Netherlands
| | - Peter Veltink
- Biomedical Signals and Systems group, Faculty of Electrical Engineering, Mathematics & Computer Science, University of Twente, Enschede, The Netherlands
| | - Ainara Garde
- Biomedical Signals and Systems group, Faculty of Electrical Engineering, Mathematics & Computer Science, University of Twente, Enschede, The Netherlands
| |
Collapse
|
10
|
Martín-Montero A, Gutiérrez-Tobal GC, Gozal D, Barroso-García V, Álvarez D, del Campo F, Kheirandish-Gozal L, Hornero R. Bispectral Analysis of Heart Rate Variability to Characterize and Help Diagnose Pediatric Sleep Apnea. ENTROPY (BASEL, SWITZERLAND) 2021; 23:1016. [PMID: 34441156 PMCID: PMC8394544 DOI: 10.3390/e23081016] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 07/28/2021] [Accepted: 08/03/2021] [Indexed: 12/28/2022]
Abstract
Pediatric obstructive sleep apnea (OSA) is a breathing disorder that alters heart rate variability (HRV) dynamics during sleep. HRV in children is commonly assessed through conventional spectral analysis. However, bispectral analysis provides both linearity and stationarity information and has not been applied to the assessment of HRV in pediatric OSA. Here, this work aimed to assess HRV using bispectral analysis in children with OSA for signal characterization and diagnostic purposes in two large pediatric databases (0-13 years). The first database (training set) was composed of 981 overnight ECG recordings obtained during polysomnography. The second database (test set) was a subset of the Childhood Adenotonsillectomy Trial database (757 children). We characterized three bispectral regions based on the classic HRV frequency ranges (very low frequency: 0-0.04 Hz; low frequency: 0.04-0.15 Hz; and high frequency: 0.15-0.40 Hz), as well as three OSA-specific frequency ranges obtained in recent studies (BW1: 0.001-0.005 Hz; BW2: 0.028-0.074 Hz; BWRes: a subject-adaptive respiratory region). In each region, up to 14 bispectral features were computed. The fast correlation-based filter was applied to the features obtained from the classic and OSA-specific regions, showing complementary information regarding OSA alterations in HRV. This information was then used to train multi-layer perceptron (MLP) neural networks aimed at automatically detecting pediatric OSA using three clinically defined severity classifiers. Both classic and OSA-specific MLP models showed high and similar accuracy (Acc) and areas under the receiver operating characteristic curve (AUCs) for moderate (classic regions: Acc = 81.0%, AUC = 0.774; OSA-specific regions: Acc = 81.0%, AUC = 0.791) and severe (classic regions: Acc = 91.7%, AUC = 0.847; OSA-specific regions: Acc = 89.3%, AUC = 0.841) OSA levels. Thus, the current findings highlight the usefulness of bispectral analysis on HRV to characterize and diagnose pediatric OSA.
Collapse
Affiliation(s)
- Adrián Martín-Montero
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
| | - Gonzalo C. Gutiérrez-Tobal
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
| | - David Gozal
- Department of Child Health and the Child Health Research Institute, The University of Missouri School of Medicine, Columbia, MO 65212, USA; (D.G.); (L.K.-G.)
| | - Verónica Barroso-García
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
| | - Daniel Álvarez
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
| | - Félix del Campo
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
- Sleep-Ventilation Unit, Pneumology Service, Río Hortega University Hospital, 47012 Valladolid, Spain
| | - Leila Kheirandish-Gozal
- Department of Child Health and the Child Health Research Institute, The University of Missouri School of Medicine, Columbia, MO 65212, USA; (D.G.); (L.K.-G.)
| | - Roberto Hornero
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
| |
Collapse
|
11
|
Martín-Montero A, Gutiérrez-Tobal GC, Kheirandish-Gozal L, Jiménez-García J, Álvarez D, del Campo F, Gozal D, Hornero R. Heart rate variability spectrum characteristics in children with sleep apnea. Pediatr Res 2021; 89:1771-1779. [PMID: 32927472 PMCID: PMC7956022 DOI: 10.1038/s41390-020-01138-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 08/04/2020] [Accepted: 08/10/2020] [Indexed: 01/04/2023]
Abstract
BACKGROUND Classic spectral analysis of heart rate variability (HRV) in pediatric sleep apnea-hypopnea syndrome (SAHS) traditionally evaluates the very low frequency (VLF: 0-0.04 Hz), low frequency (LF: 0.04-0.15 Hz), and high frequency (HF: 0.15-0.40 Hz) bands. However, specific SAHS-related frequency bands have not been explored. METHODS One thousand seven hundred and thirty-eight HRV overnight recordings from two pediatric databases (0-13 years) were evaluated. The first one (981 children) served as training set to define new HRV pediatric SAHS-related frequency bands. The associated relative power (RP) were computed in the test set, the Childhood Adenotonsillectomy Trial database (CHAT, 757 children). Their relationships with polysomnographic variables and diagnostic ability were assessed. RESULTS Two new specific spectral bands of pediatric SAHS within 0-0.15 Hz were related to duration of apneic events, number of awakenings, and wakefulness after sleep onset (WASO), while an adaptive individual-specific new band from HF was related to oxyhemoglobin desaturations, arousals, and WASO. Furthermore, these new spectral bands showed improved diagnostic ability than classic HRV. CONCLUSIONS Novel spectral bands provide improved characterization of pediatric SAHS. These findings may pioneer a better understanding of the effects of SAHS on cardiac function and potentially serve as detection biomarkers. IMPACT New specific heart rate variability (HRV) spectral bands are identified and characterized as potential biomarkers in pediatric sleep apnea. Spectral band BW1 (0.001-0.005 Hz) is related to macro sleep disruptions. Spectral band BW2 (0.028-0.074 Hz) is related to the duration of apneic events. An adaptive spectral band within the respiratory range, termed ABW3, is related to oxygen desaturations. The individual and collective diagnostic ability of these novel spectral bands outperforms classic HRV bands.
Collapse
Affiliation(s)
| | - Gonzalo C. Gutiérrez-Tobal
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain.,CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain
| | - Leila Kheirandish-Gozal
- Department of Child Health and The Child Health Research Institute, The University of Missouri School of Medicine, Columbia, Missouri
| | | | - Daniel Álvarez
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain.,CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain.,Sleep-Ventilation Unit, Pneumology Department, Río Hortega University Hospital, Valladolid, Spain
| | - Félix del Campo
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain.,CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain.,Sleep-Ventilation Unit, Pneumology Department, Río Hortega University Hospital, Valladolid, Spain
| | - David Gozal
- Department of Child Health and The Child Health Research Institute, The University of Missouri School of Medicine, Columbia, Missouri
| | - Roberto Hornero
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain.,CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain
| |
Collapse
|
12
|
JIANG XINGE, WEI SHOUSHUI, ZHAO LINA, LIU FEIFEI, LIU CHENGYU. ANALYSIS OF PHOTOPLETHYSMOGRAPHIC MORPHOLOGY IN SLEEP APNEA SYNDROME PATIENTS USING CURVE FITTING AND SUPPORT VECTOR MACHINE. J MECH MED BIOL 2021. [DOI: 10.1142/s0219519421400194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
This paper develops a time-saving, simple, and comfortable method for detecting Sleep Apnea Syndrome (SAS). Seventy SAS patients and 17 healthy persons were randomly selected in this study, and nine analytical parameters (i.e., [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], and [Formula: see text] of healthy persons and SAS patients during five sleep stages (i.e., W, R, N1, N2, and N3) were obtained to construct a SAS classification model based on logarithmic normal analytical parameters using the Support Vector Machine (SVM) method to fit Photoplethysmographic (PPG) signals. The results show that there were no statistical differences among the five sleep stages for either the healthy or SAS patients. However, there were significant differences in the measured logarithmic normal analytical parameters between the healthy persons and the SAS patients in each of the five sleep stages. The accuracies of the SAS classification model were 95.00%, 90.00%, 84.00%, 94.67%, and 90.77%, corresponding to the five sleep stages, respectively. The SAS classification model based on the SVM method of logarithmic normal analysis parameters can achieve higher classification accuracy for each of the five sleep stages. It can be considered to collect the patient’s pulse wave during the awake period, but not necessarily during the sleep period to classify and identify the SAS; it provides an idea for a convenient and comfortable SAS detection.
Collapse
Affiliation(s)
- XINGE JIANG
- School of Information Science and Electrical Engineering, Shandong Jiaotong University, Jinan 250357, P. R. China
- School of Control Science and Engineering, Shandong University, Jinan 250061, P. R. China
| | - SHOUSHUI WEI
- School of Control Science and Engineering, Shandong University, Jinan 250061, P. R. China
| | - LINA ZHAO
- School of Instrument Science and Engineering, Southeast University, Nanjing 210096, P. R. China
| | - FEIFEI LIU
- School of Science, Shandong Jianzhu Uniersity, Jinan 250101, P. R. China
| | - CHENGYU LIU
- School of Instrument Science and Engineering, Southeast University, Nanjing 210096, P. R. China
| |
Collapse
|
13
|
Barroso-García V, Gutiérrez-Tobal GC, Gozal D, Vaquerizo-Villar F, Álvarez D, del Campo F, Kheirandish-Gozal L, Hornero R. Wavelet Analysis of Overnight Airflow to Detect Obstructive Sleep Apnea in Children. SENSORS 2021; 21:s21041491. [PMID: 33669996 PMCID: PMC7926995 DOI: 10.3390/s21041491] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 02/16/2021] [Accepted: 02/18/2021] [Indexed: 01/08/2023]
Abstract
This study focused on the automatic analysis of the airflow signal (AF) to aid in the diagnosis of pediatric obstructive sleep apnea (OSA). Thus, our aims were: (i) to characterize the overnight AF characteristics using discrete wavelet transform (DWT) approach, (ii) to evaluate its diagnostic utility, and (iii) to assess its complementarity with the 3% oxygen desaturation index (ODI3). In order to reach these goals, we analyzed 946 overnight pediatric AF recordings in three stages: (i) DWT-derived feature extraction, (ii) feature selection, and (iii) pattern recognition. AF recordings from OSA patients showed both lower detail coefficients and decreased activity associated with the normal breathing band. Wavelet analysis also revealed that OSA disturbed the frequency and energy distribution of the AF signal, increasing its irregularity. Moreover, the information obtained from the wavelet analysis was complementary to ODI3. In this regard, the combination of both wavelet information and ODI3 achieved high diagnostic accuracy using the common OSA-positive cutoffs: 77.97%, 81.91%, and 90.99% (AdaBoost.M2), and 81.96%, 82.14%, and 90.69% (Bayesian multi-layer perceptron) for 1, 5, and 10 apneic events/hour, respectively. Hence, these findings suggest that DWT properly characterizes OSA-related severity as embedded in nocturnal AF, and could simplify the diagnosis of pediatric OSA.
Collapse
Affiliation(s)
- Verónica Barroso-García
- Biomedical Engineering Group, University of Valladolid, 47011 Valladolid, Spain; (V.B.-G.); (F.V.-V.); (D.Á.); (F.d.C.); (R.H.)
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 47011 Valladolid, Spain
| | - Gonzalo C. Gutiérrez-Tobal
- Biomedical Engineering Group, University of Valladolid, 47011 Valladolid, Spain; (V.B.-G.); (F.V.-V.); (D.Á.); (F.d.C.); (R.H.)
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 47011 Valladolid, Spain
- Correspondence: ; Tel.: +34-983-423000 (ext. 4713)
| | - David Gozal
- Department of Child Health, The University of Missouri School of Medicine, Columbia, MO 65212, USA; (D.G.); (L.K.-G.)
| | - Fernando Vaquerizo-Villar
- Biomedical Engineering Group, University of Valladolid, 47011 Valladolid, Spain; (V.B.-G.); (F.V.-V.); (D.Á.); (F.d.C.); (R.H.)
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 47011 Valladolid, Spain
| | - Daniel Álvarez
- Biomedical Engineering Group, University of Valladolid, 47011 Valladolid, Spain; (V.B.-G.); (F.V.-V.); (D.Á.); (F.d.C.); (R.H.)
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 47011 Valladolid, Spain
- Sleep-Ventilation Unit, Pneumology Department, Río Hortega University Hospital, 47012 Valladolid, Spain
| | - Félix del Campo
- Biomedical Engineering Group, University of Valladolid, 47011 Valladolid, Spain; (V.B.-G.); (F.V.-V.); (D.Á.); (F.d.C.); (R.H.)
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 47011 Valladolid, Spain
- Sleep-Ventilation Unit, Pneumology Department, Río Hortega University Hospital, 47012 Valladolid, Spain
| | - Leila Kheirandish-Gozal
- Department of Child Health, The University of Missouri School of Medicine, Columbia, MO 65212, USA; (D.G.); (L.K.-G.)
| | - Roberto Hornero
- Biomedical Engineering Group, University of Valladolid, 47011 Valladolid, Spain; (V.B.-G.); (F.V.-V.); (D.Á.); (F.d.C.); (R.H.)
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 47011 Valladolid, Spain
| |
Collapse
|
14
|
Barroso-García V, Gutiérrez-Tobal GC, Kheirandish-Gozal L, Vaquerizo-Villar F, Álvarez D, Del Campo F, Gozal D, Hornero R. Bispectral analysis of overnight airflow to improve the pediatric sleep apnea diagnosis. Comput Biol Med 2020; 129:104167. [PMID: 33385706 DOI: 10.1016/j.compbiomed.2020.104167] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2020] [Revised: 11/19/2020] [Accepted: 12/04/2020] [Indexed: 12/15/2022]
Abstract
Pediatric Obstructive Sleep Apnea (OSA) is a respiratory disease whose diagnosis is performed through overnight polysomnography (PSG). Since it is a complex, time-consuming, expensive, and labor-intensive test, simpler alternatives are being intensively sought. In this study, bispectral analysis of overnight airflow (AF) signal is proposed as a potential approach to replace PSG when indicated. Thus, our objective was to characterize AF through bispectrum, and assess its performance to diagnose pediatric OSA. This characterization was conducted using 13 bispectral features from 946 AF signals. The oxygen desaturation index ≥3% (ODI3), a common clinical measure of OSA severity, was also obtained to evaluate its complementarity to the AF bispectral analysis. The fast correlation-based filter (FCBF) and a multi-layer perceptron (MLP) were used for subsequent automatic feature selection and pattern recognition stages. FCBF selected 3 bispectral features and ODI3, which were used to train a MLP model with ability to estimate apnea-hypopnea index (AHI). The model reached 82.16%, 82.49%, and 90.15% accuracies for the common AHI cut-offs 1, 5, and 10 events/h, respectively. The different bispectral approaches used to characterize AF in children provided complementary information. Accordingly, bispectral analysis showed that the occurrence of apneic events decreases the non-gaussianity and non-linear interaction of the AF harmonic components, as well as the regularity of the respiratory patterns. Moreover, the bispectral information from AF also showed complementarity with ODI3. Our findings suggest that AF bispectral analysis may serve as a useful tool to simplify the diagnosis of pediatric OSA, particularly for children with moderate-to-severe OSA.
Collapse
Affiliation(s)
- Verónica Barroso-García
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain.
| | - Gonzalo C Gutiérrez-Tobal
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain
| | - Leila Kheirandish-Gozal
- Department of Child Health, The University of Missouri School of Medicine, Columbia, MO, USA
| | - Fernando Vaquerizo-Villar
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain
| | - Daniel Álvarez
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain; Sleep-Ventilation Unit, Pneumology Department, Río Hortega University Hospital, Valladolid, Spain
| | - Félix Del Campo
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain; Sleep-Ventilation Unit, Pneumology Department, Río Hortega University Hospital, Valladolid, Spain
| | - David Gozal
- Department of Child Health, The University of Missouri School of Medicine, Columbia, MO, USA
| | - Roberto Hornero
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain
| |
Collapse
|
15
|
|
16
|
Li X, Ling SH, Su S. A Hybrid Feature Selection and Extraction Methods for Sleep Apnea Detection Using Bio-Signals. SENSORS 2020; 20:s20154323. [PMID: 32756353 PMCID: PMC7436101 DOI: 10.3390/s20154323] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 07/06/2020] [Accepted: 07/31/2020] [Indexed: 11/16/2022]
Abstract
People with sleep apnea (SA) are at increased risk of having stroke and cardiovascular diseases. Polysomnography (PSG) is used to detect SA. This paper conducts feature selection from PSG signals and uses a support vector machine (SVM) to detect SA. To analyze SA, the Physionet Apnea Database was used to obtain various features. Electrocardiography (ECG), oxygen saturation (SaO2), airflow, abdominal, and thoracic signals were used to provide various frequency-, time-domain and non-linear features (n = 87). To analyse the significance of these features, firstly, two evaluation measures, the rank-sum method and the analysis of variance (ANOVA) were used to evaluate the significance of the features. These features were then classified according to their significance. Finally, different class feature sets were presented as inputs for an SVM classifier to detect the onset of SA. The hill-climbing feature selection algorithm and the k-fold cross-validation method were applied to evaluate each classification performance. Through the experiments, we discovered that the best feature set (including the top-five significant features) obtained the best classification performance. Furthermore, we plotted receiver operating characteristic (ROC) curves to examine the performance of the SVM, and the results showed the SVM with Linear kernel (regularization parameter = 1) outperformed other classifiers (area under curve = 95.23%, sensitivity = 94.29%, specificity = 96.17%). The results confirm that feature subsets based on multiple bio-signals have the potential to identify patients with SA. The use of a smaller subset avoids dimensionality problems and reduces the computational load.
Collapse
|
17
|
Assessment of Airflow and Oximetry Signals to Detect Pediatric Sleep Apnea-Hypopnea Syndrome Using AdaBoost. ENTROPY 2020; 22:e22060670. [PMID: 33286442 PMCID: PMC7517204 DOI: 10.3390/e22060670] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 06/09/2020] [Accepted: 06/15/2020] [Indexed: 12/17/2022]
Abstract
The reference standard to diagnose pediatric Obstructive Sleep Apnea (OSA) syndrome is an overnight polysomnographic evaluation. When polysomnography is either unavailable or has limited availability, OSA screening may comprise the automatic analysis of a minimum number of signals. The primary objective of this study was to evaluate the complementarity of airflow (AF) and oximetry (SpO2) signals to automatically detect pediatric OSA. Additionally, a secondary goal was to assess the utility of a multiclass AdaBoost classifier to predict OSA severity in children. We extracted the same features from AF and SpO2 signals from 974 pediatric subjects. We also obtained the 3% Oxygen Desaturation Index (ODI) as a common clinically used variable. Then, feature selection was conducted using the Fast Correlation-Based Filter method and AdaBoost classifiers were evaluated. Models combining ODI 3% and AF features outperformed the diagnostic performance of each signal alone, reaching 0.39 Cohens's kappa in the four-class classification task. OSA vs. No OSA accuracies reached 81.28%, 82.05% and 90.26% in the apnea-hypopnea index cutoffs 1, 5 and 10 events/h, respectively. The most relevant information from SpO2 was redundant with ODI 3%, and AF was complementary to them. Thus, the joint analysis of AF and SpO2 enhanced the diagnostic performance of each signal alone using AdaBoost, thereby enabling a potential screening alternative for OSA in children.
Collapse
|
18
|
Barroso-García V, Gutiérrez-Tobal GC, Kheirandish-Gozal L, Álvarez D, Vaquerizo-Villar F, Núñez P, Del Campo F, Gozal D, Hornero R. Usefulness of recurrence plots from airflow recordings to aid in paediatric sleep apnoea diagnosis. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 183:105083. [PMID: 31590097 DOI: 10.1016/j.cmpb.2019.105083] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 08/28/2019] [Accepted: 09/16/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND AND OBJECTIVE In-laboratory overnight polysomnography (PSG) is the gold standard method to diagnose the Sleep Apnoea-Hypopnoea Syndrome (SAHS). PSG is a complex, expensive, labour-intensive and time-consuming test. Consequently, simplified diagnostic methods are desirable. We propose the analysis of the airflow (AF) signal by means of recurrence plots (RP) features. The main goal of our study was to evaluate the utility of the information from RPs of the AF signals to detect paediatric SAHS at different levels of severity. In addition, we also evaluated the complementarity with the 3% oxygen desaturation index (ODI3). METHODS 946 AF and blood oxygen saturation (SpO2) recordings from children ages 0-13 years were used. The population under study was randomly split into training (60%) and test (40%) sets. RP was computed and 9 RP features were extracted from each AF recording. ODI3 was also calculated from each SpO2 recording. A feature selection stage was conducted in the training group by means of the fast correlation-based filter (FCBF) methodology to obtain a relevant and non-redundant optimum feature subset. A multi-layer perceptron neural network with Bayesian approach (BY-MLP), trained with these optimum features, was used to estimate the apnoea-hypopnoea index (AHI). RESULTS 8 of the RP features showed statistically significant differences (p-value <0.01) among the SAHS severity groups. FCBF selected the maximum length of the diagonal lines from RP, as well as the ODI3. Using these optimum features, the BY-MLP model achieved 83.2%, 78.5%, and 91.0% accuracy in the test group for the AHI thresholds 1, 5, and 10 events/h, respectively. Moreover, this model reached a negative likelihood ratio of 0.1 for 1 event/h and a positive likelihood ratio of 13.7 for 10 events/h. CONCLUSIONS RP analysis enables extraction of useful SAHS-related information from overnight AF paediatric recordings. Moreover, it provides complementary information to the widely-used clinical variable ODI3. Thus, RP applied to AF signals can be used along with ODI3 to help in paediatric SAHS diagnosis, particularly to either confirm the absence of SAHS or the presence of severe SAHS.
Collapse
Affiliation(s)
| | | | - Leila Kheirandish-Gozal
- Department of Child Health, The University of Missouri School of Medicine, Columbia, MO, USA
| | - Daniel Álvarez
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain; Sleep-Ventilation Unit, Pneumology Service, Río Hortega University Hospital, Valladolid, Spain
| | | | - Pablo Núñez
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain
| | - Félix Del Campo
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain; Sleep-Ventilation Unit, Pneumology Service, Río Hortega University Hospital, Valladolid, Spain
| | - David Gozal
- Department of Child Health, The University of Missouri School of Medicine, Columbia, MO, USA
| | - Roberto Hornero
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain; IMUVA, Instituto de Investigación en Matemáticas, Universidad de Valladolid, Valladolid, Spain. http://www.gib.tel.uva.es
| |
Collapse
|
19
|
Vadrevu S, Manikandan MS. Use of zero-frequency resonator for automatically detecting systolic peaks of photoplethysmogram signal. Healthc Technol Lett 2019; 6:53-58. [PMID: 31341628 PMCID: PMC6595535 DOI: 10.1049/htl.2018.5026] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2018] [Revised: 02/16/2019] [Accepted: 02/26/2019] [Indexed: 11/20/2022] Open
Abstract
This work investigates the application of zero-frequency resonator (ZFR) for detecting systolic peaks of photoplethysmogram (PPG) signals. Based on the authors' studies, they propose an automated noise-robust method, which consists of the central difference operation, the ZFR, the mean subtraction and averaging, the peak determination, and the peak rejection/acceptance rule. The method is evaluated using different kinds of PPG signals taken from the standard MIT-BIH polysomnographic database and Complex Systems Laboratory database and the recorded PPG signals at their Biomedical System Lab. The method achieves an average sensitivity (Se) of 99.95%, positive predictivity (Pp) of 99.89%, and overall accuracy (OA) of 99.84% on a total number of 116,673 true peaks. Evaluation results further demonstrate the robustness of the ZFR-based method for noisy PPG signals with a signal-to-noise ratio (SNR) ranging from 30 to 5 dB. The method achieves an average Se = 99.76%, Pp = 99.84%, and OA = 99.60% for noisy PPG signals with a SNR of 5 dB. Various results show that the method yields better detection rates for both noise-free and noisy PPG signals. The method is simple and reliable as compared with the complexity of signal processing techniques and detection performance of the existing detection methods.
Collapse
Affiliation(s)
- Simhadri Vadrevu
- School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Kurdha, Odisha-752050, India
| | - M Sabarimalai Manikandan
- School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Kurdha, Odisha-752050, India
| |
Collapse
|
20
|
Bertoni D, Isaiah A. Towards Patient-centered Diagnosis of Pediatric Obstructive Sleep Apnea—A Review of Biomedical Engineering Strategies. Expert Rev Med Devices 2019; 16:617-629. [DOI: 10.1080/17434440.2019.1626233] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Dylan Bertoni
- Department of Otorhinolaryngology—Head and Neck Surgery, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Amal Isaiah
- Department of Otorhinolaryngology—Head and Neck Surgery, University of Maryland School of Medicine, Baltimore, MD, USA
| |
Collapse
|
21
|
Gutierrez-Tobal GC, Kheirandish-Gozal L, Vaquerizo-Villar F, Alvarez D, Barroso-Garcia V, Crespo A, Campo FD, Gozal D, Hornero R. Bispectral Analysis to Enhance Oximetry as a Simplified Alternative for Pediatric Sleep Apnea Diagnosis. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:175-178. [PMID: 30440366 DOI: 10.1109/embc.2018.8512248] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
This study aims at assessing the bispectral analysis of blood oxygen saturation (SpO2) from nocturnal oximetry to help in pediatric sleep apnea-hypopnea syndrome (SAHS) diagnosis. Recent studies have found excessive redundancy in the SAHS-related information usually extracted from SpO2, while proposing only two features as a reduced set to be used. On the other hand, it has been suggested that SpO2 bispectral analysis is able to provide complementary information to common anthropometric, spectral, and clinical variables. We address these novel findings to assess whether bispectrum provides new non-redundant information to help in SAHS diagnosis. Thus, we use 981 pediatric SpO2 recordings to extract both the reduced set of features recently proposed as well as 9 bispectral features. Then, a feature selection method based on the fast correlationbased filter and bootstrapping is used to assess redundancy among all the features. Finally, the non-redundant ones are used to train a Bayesian multi-layer perceptron neural network (BYMLP) that estimate the apnea-hypopnea index (AHI), which is the diagnostic reference variable. Bispectral phase entropy was found complementary to the two previously recommended features and a BY-MLP model trained with the three of them reached high agreement with actual AHI (intra-class correlation coefficient = 0.889). Estimated AHI also showed high diagnostic ability, reaching 82.1%, 81.9%, and 90.3% accuracies and 0.814, 0.880, and 0.922 area under the receiver-operating characteristics curve for three common AHI thresholds: 1 e/h, 5 e/h, and 10 e/h, respectively. These results suggest that the information extracted from the bispectrum of SpO2 can improve the diagnostic performance of the oximetry test.
Collapse
|
22
|
Lee H, Kim E, Lee Y, Kim H, Lee J, Kim M, Yoo HJ, Yoo S. Toward all-day wearable health monitoring: An ultralow-power, reflective organic pulse oximetry sensing patch. SCIENCE ADVANCES 2018; 4:eaas9530. [PMID: 30430132 PMCID: PMC6226280 DOI: 10.1126/sciadv.aas9530] [Citation(s) in RCA: 99] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Accepted: 10/03/2018] [Indexed: 05/17/2023]
Abstract
Pulse oximetry sensors have been playing a key role as devices to monitor elemental yet critical human health states. Conventional pulse oximetry sensors, however, have relatively large power consumption, impeding their use as stand-alone, continuous monitoring systems that can easily be integrated with everyday life. Here, we exploit the design freedom offered by organic technologies to realize a reflective patch-type pulse oximetry sensor with ultralow power consumption. On the basis of flexible organic light-emitting diodes and organic photodiodes designed via an optical simulation of color-sensitive light propagation within human skin, the proposed monolithically integrated organic pulse oximetry sensor heads exhibit successful operation at electrical power as low as 24 μW on average. We thereby demonstrate that organic devices not only have form factor advantages for such applications but also hold great promise as enablers for all-day wearable health monitoring systems.
Collapse
|
23
|
Jayawardhana M, de Chazal P. Enhanced detection of sleep apnoea using heart-rate, respiration effort and oxygen saturation derived from a photoplethysmography sensor. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2017:121-124. [PMID: 29059825 DOI: 10.1109/embc.2017.8036777] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This paper presents a study on identifying sleep apnoea using the photoplethysmography (PPG) measurements, which is obtained from the SpO2 sensor. Using a database of polysomnogram (PSG) records of 52 patients, the heart rate and breathing effort information was derived from the PPG measurements and then features are extracted and processed by a classifier to detect one-minute epochs of sleep apnoea. The ground truth labels for the epochs were determined by trained technicians using the full PSG signal. Pulse oximetry (SpO2) measurements from the same sensor are also used in the classification process for comparison and in combination with the PPG results. The results show that both the heart rate and respiratory effort information derived from the PPG signal were able to detect apnoeic epochs with some success. The best classification performance of 87% for correctly labelling the epochs was obtained when the SpO2 features and the PPG features were combined.
Collapse
|
24
|
Vaquerizo-Villar F, Álvarez D, Kheirandish-Gozal L, Gutiérrez-Tobal GC, Barroso-García V, Crespo A, Del Campo F, Gozal D, Hornero R. Utility of bispectrum in the screening of pediatric sleep apnea-hypopnea syndrome using oximetry recordings. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2018; 156:141-149. [PMID: 29428066 DOI: 10.1016/j.cmpb.2017.12.020] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2017] [Revised: 12/11/2017] [Accepted: 12/21/2017] [Indexed: 06/08/2023]
Abstract
BACKGROUND AND OBJECTIVE The aim of this study was to assess the utility of bispectrum-based oximetry approaches as a complementary tool to traditional techniques in the screening of pediatric sleep apnea-hypopnea syndrome (SAHS). METHODS 298 blood oxygen saturation (SpO2) signals from children ranging 0-13 years of age were recorded during overnight polysomnography (PSG). These recordings were divided into three severity groups according to the PSG-derived apnea hypopnea index (AHI): AHI < 5 events per hour (e/h), 5 ≤ AHI < 10 e/h, AHI ≥ 10 e/h. For each pediatric subject, anthropometric variables, 3% oxygen desaturation index (ODI3) and spectral features from power spectral density (PSD) and bispectrum were obtained. Then, the fast correlation-based filter (FCBF) was applied to select a subset of relevant features that may be complementary, excluding those that are redundant. The selected features fed a multiclass multi-layer perceptron (MLP) neural network to build a model to estimate the SAHS severity degrees. RESULTS An optimum subset with features from all the proposed methodological approaches was obtained: variables from bispectrum, as well as PSD, ODI3, Age, and Sex. In the 3-class classification task, the MLP model trained with these features achieved an accuracy of 76.0% and a Cohen's kappa of 0.56 in an independent test set. Additionally, high accuracies were reached using the AHI cutoffs for diagnosis of moderate (AHI = 5 e/h) and severe (AHI = 10 e/h) SAHS: 81.3% and 85.3%, respectively. These results outperformed the diagnostic ability of a MLP model built without using bispectral features. CONCLUSIONS Our results suggest that bispectrum provides additional information to anthropometric variables, ODI3 and PSD regarding characterization of changes in the SpO2 signal caused by respiratory events. Thus, oximetry bispectrum can be a useful tool to provide complementary information for screening of moderate-to-severe pediatric SAHS.
Collapse
Affiliation(s)
| | - Daniel Álvarez
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain; Servicio de Neumología, Hospital Universitario Rio Hortega, Valladolid, Spain
| | - Leila Kheirandish-Gozal
- Dept. of Pediatrics, Pritzker School of Medicine, Biological Sciences Division, The University of Chicago, Chicago, United States of America
| | | | | | - Andrea Crespo
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain; Servicio de Neumología, Hospital Universitario Rio Hortega, Valladolid, Spain
| | - Félix Del Campo
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain; Servicio de Neumología, Hospital Universitario Rio Hortega, Valladolid, Spain
| | - David Gozal
- Dept. of Pediatrics, Pritzker School of Medicine, Biological Sciences Division, The University of Chicago, Chicago, United States of America
| | - Roberto Hornero
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain; IMUVA, Instituto de Investigación en Matemáticas, Universidad de Valladolid, Valladolid, Spain
| |
Collapse
|
25
|
Assessment of oximetry-based statistical classifiers as simplified screening tools in the management of childhood obstructive sleep apnea. Sleep Breath 2018; 22:1063-1073. [PMID: 29453636 DOI: 10.1007/s11325-018-1637-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Revised: 01/12/2018] [Accepted: 01/28/2018] [Indexed: 10/18/2022]
Abstract
PURPOSE A variety of statistical models based on overnight oximetry has been proposed to simplify the detection of children with suspected obstructive sleep apnea syndrome (OSAS). Despite the usefulness reported, additional thorough comparative analyses are required. This study was aimed at assessing common binary classification models from oximetry for the detection of childhood OSAS. METHODS Overnight oximetry recordings from 176 children referred for clinical suspicion of OSAS were acquired during in-lab polysomnography. Several training and test datasets were randomly composed by means of bootstrapping for model optimization and independent validation. For every child, blood oxygen saturation (SpO2) was parameterized by means of 17 features. Fast correlation-based filter (FCBF) was applied to search for the optimum features. The discriminatory power of three statistical pattern recognition algorithms was assessed: linear discriminant analysis (LDA), quadratic discriminant analysis (QDA), and logistic regression (LR). The performance of each automated model was evaluated for the three common diagnostic polysomnographic cutoffs in pediatric OSAS: 1, 3, and 5 events/h. RESULTS Best screening performances emerged using the 1 event/h cutoff for mild-to-severe childhood OSAS. LR achieved 84.3% accuracy (95% CI 76.8-91.5%) and 0.89 AUC (95% CI 0.83-0.94), while QDA reached 96.5% PPV (95% CI 90.3-100%) and 0.91 AUC (95% CI 0.85-0.96%). Moreover, LR and QDA reached diagnostic accuracies of 82.7% (95% CI 75.0-89.6%) and 82.1% (95% CI 73.8-89.5%) for a cutoff of 5 events/h, respectively. CONCLUSIONS Automated analysis of overnight oximetry may be used to develop reliable as well as accurate screening tools for childhood OSAS.
Collapse
|
26
|
Smith LA, Dawes PJ, Galland BC. The use of pulse transit time in pediatric sleep studies: A systematic review. Sleep Med Rev 2018; 37:4-13. [DOI: 10.1016/j.smrv.2016.11.006] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Revised: 09/09/2016] [Accepted: 11/17/2016] [Indexed: 12/19/2022]
|
27
|
Irregularity and Variability Analysis of Airflow Recordings to Facilitate the Diagnosis of Paediatric Sleep Apnoea-Hypopnoea Syndrome. ENTROPY 2017. [DOI: 10.3390/e19090447] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
28
|
Shalish W, Kanbar LJ, Rao S, Robles-Rubio CA, Kovacs L, Chawla S, Keszler M, Precup D, Brown K, Kearney RE, Sant'Anna GM. Prediction of Extubation readiness in extremely preterm infants by the automated analysis of cardiorespiratory behavior: study protocol. BMC Pediatr 2017; 17:167. [PMID: 28716018 PMCID: PMC5512825 DOI: 10.1186/s12887-017-0911-z] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Accepted: 06/29/2017] [Indexed: 11/10/2022] Open
Abstract
Background Extremely preterm infants (≤ 28 weeks gestation) commonly require endotracheal intubation and mechanical ventilation (MV) to maintain adequate oxygenation and gas exchange. Given that MV is independently associated with important adverse outcomes, efforts should be made to limit its duration. However, current methods for determining extubation readiness are inaccurate and a significant number of infants fail extubation and require reintubation, an intervention that may be associated with increased morbidities. A variety of objective measures have been proposed to better define the optimal time for extubation, but none have proven clinically useful. In a pilot study, investigators from this group have shown promising results from sophisticated, automated analyses of cardiorespiratory signals as a predictor of extubation readiness. The aim of this study is to develop an automated predictor of extubation readiness using a combination of clinical tools along with novel and automated measures of cardiorespiratory behavior, to assist clinicians in determining when extremely preterm infants are ready for extubation. Methods In this prospective, multicenter observational study, cardiorespiratory signals will be recorded from 250 eligible extremely preterm infants with birth weights ≤1250 g immediately prior to their first planned extubation. Automated signal analysis algorithms will compute a variety of metrics for each infant, and machine learning methods will then be used to find the optimal combination of these metrics together with clinical variables that provide the best overall prediction of extubation readiness. Using these results, investigators will develop an Automated system for Prediction of EXtubation (APEX) readiness that will integrate the software for data acquisition, signal analysis, and outcome prediction into a single application suitable for use by medical personnel in the neonatal intensive care unit. The performance of APEX will later be prospectively validated in 50 additional infants. Discussion The results of this research will provide the quantitative evidence needed to assist clinicians in determining when to extubate a preterm infant with the highest probability of success, and could produce significant improvements in extubation outcomes in this population. Trial registration Clinicaltrials.gov identifier: NCT01909947. Registered on July 17 2013. Trial sponsor: Canadian Institutes of Health Research (CIHR). Electronic supplementary material The online version of this article (doi:10.1186/s12887-017-0911-z) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Wissam Shalish
- Department of Pediatrics, Division of Neonatology, Montreal Children's Hospital, McGill University, 1001 Boul. Décarie, room B05.2714. Montreal, Quebec, H4A 3J1, Canada
| | - Lara J Kanbar
- Department of Biomedical Engineering, McGill University, Montreal, Quebec, H3A 2B4, Canada
| | - Smita Rao
- Department of Pediatrics, Division of Neonatology, Montreal Children's Hospital, McGill University, 1001 Boul. Décarie, room B05.2714. Montreal, Quebec, H4A 3J1, Canada
| | - Carlos A Robles-Rubio
- Department of Biomedical Engineering, McGill University, Montreal, Quebec, H3A 2B4, Canada
| | - Lajos Kovacs
- Department of Neonatology, Jewish General Hospital, Montreal, Quebec, H3T 1E2, Canada
| | - Sanjay Chawla
- Division of Neonatal-Perinatal Medicine, Hutzel Women's Hospital, Wayne State University, Detroit, MI, 48201, USA
| | - Martin Keszler
- Department of Pediatrics, Women and Infants Hospital of Rhode Island, Brown University, Providence, RI, 02905, USA
| | - Doina Precup
- Department of Computer Science, McGill University, Montreal, Quebec, H3A 0E9, Canada
| | - Karen Brown
- Department of Anesthesia, Montreal Children's Hospital, McGill University Health Center, Montreal, Quebec, H4A 3J1, Canada
| | - Robert E Kearney
- Department of Biomedical Engineering, McGill University, Montreal, Quebec, H3A 2B4, Canada
| | - Guilherme M Sant'Anna
- Department of Pediatrics, Division of Neonatology, Montreal Children's Hospital, McGill University, 1001 Boul. Décarie, room B05.2714. Montreal, Quebec, H4A 3J1, Canada.
| |
Collapse
|
29
|
Bolea J, Lázaro J, Gil E, Rovira E, Remartínez JM, Laguna P, Pueyo E, Navarro A, Bailón R. Pulse Rate and Transit Time Analysis to Predict Hypotension Events After Spinal Anesthesia During Programmed Cesarean Labor. Ann Biomed Eng 2017; 45:2253-2263. [DOI: 10.1007/s10439-017-1864-y] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Accepted: 05/30/2017] [Indexed: 12/11/2022]
|
30
|
Shahrbabaki SS, Ahmed B, Penzel T, Cvetkovic D. Photoplethysmography derivatives and pulse transit time in overnight blood pressure monitoring. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:2855-2858. [PMID: 28268912 DOI: 10.1109/embc.2016.7591325] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Overnight continuous blood pressure measurement provides simultaneous monitoring of blood pressure and sleep architecture. By this means, we are able to investigate whether different sleep events are associated to blood pressure fluctuations. In this paper, we used the Pulse Transit Time (PTT) to develop and evaluate functions for measurement of blood pressure. We focused on the first and second derivatives of fingertip Photoplethysmography (PPG) recordings to detect PPG critical points. By applying R wave of ECG and PPG critical points, we created two PTT-based models for estimation of systolic and diastolic blood pressure (SBP and DBP). Seven subjects polysomnography datasets that contained PPG, ECG and blood pressure recordings were utilised to validate and compare developed PTT-BP functions. Results found that if the peak of the first derivative of PPG (VPG) was considered as the pulse pressure arrival point, the resulted PTT (PTTV) would more accurately predict both SBP and DBP. The average R-squared coefficient for SBP and DBP were correspondingly 0.593 and 0.416. The obtained mean error for PTTV based functions in SBP was ±3.96 mmHg with standard deviation of 1.41 mmHg and in DBP was ±6.88 mmHg with standard deviation of 3.03 mmHg. We concluded PTT detected from VPG is a reliable and suitable maker for overnight continuous blood pressure monitoring.
Collapse
|
31
|
Multiscale Entropy Analysis of Unattended Oximetric Recordings to Assist in the Screening of Paediatric Sleep Apnoea at Home. ENTROPY 2017. [DOI: 10.3390/e19060284] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
32
|
Correntropy-Based Pulse Rate Variability Analysis in Children with Sleep Disordered Breathing. ENTROPY 2017. [DOI: 10.3390/e19060282] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
33
|
van Velzen MHN, Loeve AJ, Niehof SP, Mik EG. Increasing accuracy of pulse transit time measurements by automated elimination of distorted photoplethysmography waves. Med Biol Eng Comput 2017; 55:1989-2000. [PMID: 28361357 PMCID: PMC5644691 DOI: 10.1007/s11517-017-1642-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Accepted: 03/20/2017] [Indexed: 11/03/2022]
Abstract
Photoplethysmography (PPG) is a widely available non-invasive optical technique to visualize pressure pulse waves (PWs). Pulse transit time (PTT) is a physiological parameter that is often derived from calculations on ECG and PPG signals and is based on tightly defined characteristics of the PW shape. PPG signals are sensitive to artefacts. Coughing or movement of the subject can affect PW shapes that much that the PWs become unsuitable for further analysis. The aim of this study was to develop an algorithm that automatically and objectively eliminates unsuitable PWs. In order to develop a proper algorithm for eliminating unsuitable PWs, a literature study was conducted. Next, a '7Step PW-Filter' algorithm was developed that applies seven criteria to determine whether a PW matches the characteristics required to allow PTT calculation. To validate whether the '7Step PW-Filter' eliminates only and all unsuitable PWs, its elimination results were compared to the outcome of manual elimination of unsuitable PWs. The '7Step PW-Filter' had a sensitivity of 96.3% and a specificity of 99.3%. The overall accuracy of the '7Step PW-Filter' for detection of unsuitable PWs was 99.3%. Compared to manual elimination, using the '7Step PW-Filter' reduces PW elimination times from hours to minutes and helps to increase the validity, reliability and reproducibility of PTT data.
Collapse
Affiliation(s)
- Marit H N van Velzen
- Department of Anesthesiology, Laboratory of Experimental Anesthesiology, Erasmus University Medical Center, Room Ee2381, PO Box 2040, 3000 CA, Rotterdam, The Netherlands.
| | - Arjo J Loeve
- Department of BioMechanical Engineering, Faculty 3mE, Delft University of Technology, Delft, The Netherlands
| | - Sjoerd P Niehof
- Department of Anesthesiology, Laboratory of Experimental Anesthesiology, Erasmus University Medical Center, Room Ee2381, PO Box 2040, 3000 CA, Rotterdam, The Netherlands
| | - Egbert G Mik
- Department of Anesthesiology, Laboratory of Experimental Anesthesiology, Erasmus University Medical Center, Room Ee2381, PO Box 2040, 3000 CA, Rotterdam, The Netherlands
| |
Collapse
|
34
|
Jang DG, Park SH, Hahn M. A Gaussian Model-Based Probabilistic Approach for Pulse Transit Time Estimation. IEEE J Biomed Health Inform 2016; 20:128-34. [DOI: 10.1109/jbhi.2014.2372047] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
35
|
Garde A, Karlen W, Dehkordi P, Wensley D, Ansermino JM, Dumont GA. Oxygen saturation in children with and without obstructive sleep apnea using the phone-oximeter. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:2531-4. [PMID: 24110242 DOI: 10.1109/embc.2013.6610055] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Obstructive sleep apnea (OSA) in children can lead to daytime sleepiness, growth failure and developmental delay. Polysomnography (PSG), the gold standard to diagnose OSA is highly resource intensive and is confined to the sleep laboratory. In this study we propose to identify children with OSA using blood oxygen saturation (SpO2) obtained from the Phone Oximeter. This portable, in-home device is able to monitor patients over multiple nights, causes less sleep disturbance and facilitates a more natural sleep pattern. The proposed algorithm analyzes the SpO2 signal in the time and frequency domain using a 90-s sliding window. Three spectral parameters are calculated from the power spectral density (PSD) to evaluate the modulation in the SpO2 due to the oxyhemoblobin desaturations. The power P, slope S in the discriminant band (DB), and ratio R between P and total power are calculated for each window. Tendency and variability indices, number of SpO2 desaturations and time spent under 2% or 3% of baseline saturation level are computed for each time window. The statistical distribution of the temporal evolution of all parameters is analyzed to identify 68 children, 30 with OSA and 38 without OSA (nonOSA). This characterization was evaluated by a feature selection based on a linear discriminant. The combination of temporal and spectral parameters provided the best leave one out crossvalidation results with an accuracy of 86.8%, a sensitivity of 80.0%, and a specificity of 92.1% using only 5 parameters. The median of R, mean of P and S and mean and standard deviation of the number of desaturations below 3% of baseline saturation level, were the most representative parameters. Hence, a better knowledge of SpO2 dynamics could help identifying children with OSA with the Phone Oximeter.
Collapse
|
36
|
Gutierrez-Tobal GC, Kheirandish-Gozal L, Alvarez D, Crespo A, Philby MF, Mohammadi M, Del Campo F, Gozal D, Hornero R. Analysis and classification of oximetry recordings to predict obstructive sleep apnea severity in children. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2015:4540-4543. [PMID: 26737304 DOI: 10.1109/embc.2015.7319404] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Current study is focused around the potential use of oximetry to determine the obstructive sleep apnea-hypopnea syndrome (OSAHS) severity in children. Single-channel SpO2 recordings from 176 children were divided into three severity groups according to the apnea-hypopnea index (AHI): AHI<;1 events per hour (e/h), 1≤AHI<;5 e/h, and AHI ≥5 e/h. Spectral analysis was conducted to define and characterize a frequency band of interest in SpO2. Then we combined the spectral data with the 3% oxygen desaturation index (ODI3) by means of a multi-layer perceptron (MLP) neural network, in order to classify children into one of the three OSAHS severity groups. Following our MLP multiclass approach, a diagnostic protocol with capability to reduce the need of polysomnography tests by 46% could be derived. Moreover, our proposal can be also evaluated, in a binary classification task for two common AHI diagnostic cutoffs (AHI = 1 e/h and AHI= 5 e/h). High diagnostic ability was reached in both cases (84.7% and 85.8% accuracy, respectively) outperforming the clinical variable ODI3 as well as other measures reported in recent studies. These results suggest that the information contained in SpO2 could be helpful in pediatric OSAHS severity detection.
Collapse
|
37
|
Gutiérrez-Tobal GC, Alonso-Álvarez ML, Álvarez D, del Campo F, Terán-Santos J, Hornero R. Diagnosis of pediatric obstructive sleep apnea: Preliminary findings using automatic analysis of airflow and oximetry recordings obtained at patients’ home. Biomed Signal Process Control 2015. [DOI: 10.1016/j.bspc.2015.02.014] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
38
|
Gutierrez-Tobal GC, Alvarez D, Alonso ML, Teran J, Del Campo F, Hornero R. Exploring the spectral information of airflow recordings to help in pediatric Obstructive Sleep Apnea-Hypopnea Syndrome diagnosis. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:2298-301. [PMID: 25570447 DOI: 10.1109/embc.2014.6944079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
This work aims at studying the usefulness of the spectral information contained in airflow (AF) recordings in the context of Obstructive Sleep Apnea-Hypopnea Syndrome (OSAHS) in children. To achieve this goal, we defined two spectral bands of interest related to the occurrence of apneas and hypopneas. We characterized these bands by extracting six common spectral features from each one. Two out of the 12 features reached higher diagnostic ability than the 3% oxygen desaturation index (ODI3), a clinical parameter commonly used as screener for OSAHS. Additionally, the stepwise logistic regression (SLR) feature-selection algorithm showed that the information contained in the two bands was complementary, both between them and with ODI3. Finally, the logistic regression method involving spectral features from the two bands, as well as ODI3, achieved high diagnostic performance after a bootstrap validation procedure (84.6±9.6 sensitivity, 87.2±9.1 specificity, 85.8±5.2 accuracy, and 0.969±0.03 area under ROC curve). These results suggest that the spectral information from AF is helpful to detect OSAHS in children.
Collapse
|
39
|
Álvarez D, Gutierrez-Tobal GC, Alonso ML, Teran J, del Campo F, Hornero R. Statistical and nonlinear analysis of oximetry from respiratory polygraphy to assist in the diagnosis of Sleep Apnea in children. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:1860-3. [PMID: 25570340 DOI: 10.1109/embc.2014.6943972] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Obstructive Sleep Apnea-Hypopnea Syndrome (OSAHS) is a sleep related breathing disorder that has important consequences in the health and development of infants and young children. To enhance the early detection of OSAHS, we propose a methodology based on automated analysis of nocturnal blood oxygen saturation (SpO(2)) from respiratory polygraphy (RP) at home. A database composed of 50 SpO(2) recordings was analyzed. Three signal processing stages were carried out: (i) feature extraction, where statistical features and nonlinear measures were computed and combined with conventional oximetric indexes, (ii) feature selection using genetic algorithms (GAs), and (iii) feature classification through logistic regression (LR). Leave-one-out cross-validation (loo-cv) was applied to assess diagnostic performance. The proposed method reached 80.8% sensitivity, 79.2% specificity, 80.0% accuracy and 0.93 area under the ROC curve (AROC), which improved the performance of single conventional indexes. Our results suggest that automated analysis of SpO(2) recordings from at-home RP provides essential and complementary information to assist in OSAHS diagnosis in children.
Collapse
|
40
|
Development of a screening tool for sleep disordered breathing in children using the phone Oximeter™. PLoS One 2014; 9:e112959. [PMID: 25401696 PMCID: PMC4234680 DOI: 10.1371/journal.pone.0112959] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2014] [Accepted: 10/13/2014] [Indexed: 11/24/2022] Open
Abstract
Background Sleep disordered breathing (SDB) can lead to daytime sleepiness, growth failure and developmental delay in children. Polysomnography (PSG), the gold standard to diagnose SDB, is a highly resource-intensive test, confined to the sleep laboratory. Aim To combine the blood oxygen saturation (SpO2) characterization and cardiac modulation, quantified by pulse rate variability (PRV), to identify children with SDB using the Phone Oximeter, a device integrating a pulse oximeter with a smartphone. Methods Following ethics approval and informed consent, 160 children referred to British Columbia Children's Hospital for overnight PSG were recruited. A second pulse oximeter sensor applied to the finger adjacent to the one used for standard PSG was attached to the Phone Oximeter to record overnight pulse oximetry (SpO2 and photoplethysmogram (PPG)) alongside the PSG. Results We studied 146 children through the analysis of the SpO2 pattern, and PRV as an estimate of heart rate variability calculated from the PPG. SpO2 variability and SpO2 spectral power at low frequency, was significantly higher in children with SDB due to the modulation provoked by airway obstruction during sleep (p-value ). PRV analysis reflected a significant augmentation of sympathetic activity provoked by intermittent hypoxia in SDB children. A linear classifier was trained with the most discriminating features to identify children with SDB. The classifier was validated with internal and external cross-validation, providing a high negative predictive value (92.6%) and a good balance between sensitivity (88.4%) and specificity (83.6%). Combining SpO2 and PRV analysis improved the classification performance, providing an area under the receiver operating characteristic curve of 88%, beyond the 82% achieved using SpO2 analysis alone. Conclusions These results demonstrate that the implementation of this algorithm in the Phone Oximeter will provide an improved portable, at-home screening tool, with the capability of monitoring patients over multiple nights.
Collapse
|
41
|
Chon KH, Yang B, Posada-Quintero HF, Siu KL, Rolle M, Brink P, Birzgalis A, Moore LC. A novel quantitative method for diabetic cardiac autonomic neuropathy assessment in type 1 diabetic mice. J Diabetes Sci Technol 2014; 8:1157-67. [PMID: 25097056 PMCID: PMC4455481 DOI: 10.1177/1932296814545669] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
In this work, we used a sensitive and noninvasive computational method to assess diabetic cardiovascular autonomic neuropathy (DCAN) from pulse oximeter (photoplethysmographic; PPG) recordings from mice. The method, which could be easily applied to humans, is based on principal dynamic mode (PDM) analysis of heart rate variability (HRV). Unlike the power spectral density, PDM has been shown to be able to separately identify the activities of the parasympathetic and sympathetic nervous systems without pharmacological intervention. HRV parameters were measured by processing PPG signals from conscious 1.5- to 5-month-old C57/BL6 control mice and in Akita mice, a model of insulin-dependent type 1 diabetes, and compared with the gold-standard Western blot and immunohistochemical analyses. The PDM results indicate significant cardiac autonomic impairment in the diabetic mice in comparison to the controls. When tail-cuff PPG recordings were collected and analyzed starting from 1.5 months of age in both C57/Bl6 controls and Akita mice, onset of DCAN was seen at 3 months in the Akita mice, which persisted up to the termination of the recording at 5 months. Western blot and immunohistochemical analyses also showed a reduction in nerve density in Akita mice at 3 and 4 months as compared to the control mice, thus, corroborating our PDM data analysis of HRV records. Western blot analysis of autonomic nerve proteins corroborated the PPG-based HRV analysis via the PDM approach. In contrast, traditional HRV analysis (based on either the power spectral density or time-domain measures) failed to detect the nerve rarefaction.
Collapse
Affiliation(s)
- Ki H Chon
- Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Bufan Yang
- Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Hugo F Posada-Quintero
- Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Kin L Siu
- Department of Medicine, University of California, Los Angeles, CA, USA
| | - Marsha Rolle
- Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Peter Brink
- Department of Physiology & Biophysics, Stony Brook University, Stony Brook, NY, USA
| | - Aija Birzgalis
- Department of Physiology & Biophysics, Stony Brook University, Stony Brook, NY, USA
| | - Leon C Moore
- Department of Physiology & Biophysics, Stony Brook University, Stony Brook, NY, USA
| |
Collapse
|
42
|
Automated prediction of early blood transfusion and mortality in trauma patients. J Trauma Acute Care Surg 2014; 76:1379-85. [PMID: 24854304 DOI: 10.1097/ta.0000000000000235] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Prediction of blood transfusion needs and mortality for trauma patients in near real time is an unrealized goal. We hypothesized that analysis of pulse oximeter signals could predict blood transfusion and mortality as accurately as conventional vital signs (VSs). METHODS Continuous VS data were recorded for direct admission trauma patients with abnormal prehospital shock index (SI = heart rate [HR] / systolic blood pressure) greater than 0.62. Predictions of transfusion during the first 24 hours and in-hospital mortality using logistical regression models were compared with DeLong's method for areas under receiver operating characteristic curves (AUROCs) to determine the optimal combinations of prehospital SI and HR, continuous photoplethysmographic (PPG), oxygen saturation (SpO2), and HR-related features. RESULTS We enrolled 556 patients; 37 received blood within 24 hours; 7 received more than 4 U of red blood cells in less than 4 hours or "massive transfusion" (MT); and 9 died. The first 15 minutes of VS signals, including prehospital HR plus continuous PPG, and SpO2 HR signal analysis best predicted transfusion at 1 hour to 3 hours, MT, and mortality (AUROC, 0.83; p < 0.03) and no differently (p = 0.32) from a model including blood pressure. Predictions of transfusion based on the first 15 minutes of data were no different using 30 minutes to 60 minutes of data collection. SI plus PPG and SpO2 signal analysis (AUROC, 0.82) predicted 1-hour to 3-hour transfusion, MT, and mortality no differently from pulse oximeter signals alone. CONCLUSION Pulse oximeter features collected in the first 15 minutes of our trauma patient resuscitation cohort, without user input, predicted early MT and mortality in the critical first hours of care better than the currently used VS such as combinations of HR and systolic blood pressure or prehospital SI alone. LEVEL OF EVIDENCE Therapeutic/prognostic study, level II.
Collapse
|
43
|
Orini M, Citi L, Barbieri R. Bivariate point process modeling and joint non-stationary analysis of pulse transit time and heart period. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2012:2831-4. [PMID: 23366514 DOI: 10.1109/embc.2012.6346553] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Pulse transit time (PTT) is strictly related to pulse wave velocity and may be used for non-invasive monitoring of arterial stiffness and pressure, whose assessment is fundamental to detect cardiovascular dysfunctions. We propose a new model to characterize instantaneous PTT dynamics, and the interactions between PTT and R-R interval (RRI). In this model, PTT is described as a point process whose probability function depends on previous PTT and RRI values. From the model coefficients, instantaneous powers, coherence and directed coherence of each spectral component are estimated. We used this framework to study the changes that tilt table test provoked in PTT and RRI dynamics in 17 healthy subjects. Time-varying spectral and coherence analysis revealed that, although PTT and RRI were locally correlated, direct contribution of RRI on PTT was low during the entire test in high frequency band, and just after postural changes in low frequency band. We conclude that PTT may add valuable information for a more accurate characterization of cardiovascular regulation.
Collapse
Affiliation(s)
- Michele Orini
- GTC, I3A, IIS Aragón, Universidad de Zaragoza, Zaragoza, Spain.
| | | | | |
Collapse
|
44
|
Lázaro J, Gil E, Bailón R, Mincholé A, Laguna P. Deriving respiration from photoplethysmographic pulse width. Med Biol Eng Comput 2012; 51:233-42. [PMID: 22996834 DOI: 10.1007/s11517-012-0954-0] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2012] [Accepted: 08/08/2012] [Indexed: 11/28/2022]
Abstract
A method for deriving respiration from the pulse photoplethysmographic (PPG) signal is presented. This method is based on the pulse width variability (PWV), and it exploits the respiratory information present in the pulse wave velocity and dispersion. It allows to estimate respiration signal from only a pulse oximeter which is a cheap and comfortable sensor. Evaluation is performed over a database containing electrocardiogram (ECG), blood pressure (BP), PPG, and respiratory signals simultaneously recorded in 17 subjects during a tilt table test. Respiratory rate estimation error is computed obtaining of 1.27 ± 7.81% (0.14 ± 14.78 mHz). For comparison purposes, we have also obtained a respiratory rate estimation from other known methods which involve ECG, BP, or also PPG signals. In addition, we have also combined respiratory information derived from different methods which involve only PPG signal, obtaining a respiratory rate error of -0.17 ± 6.67% (-2.16 ± 12.69 mHz). The presented methods, PWV and combination of PPG derived respiration methods, avoid the need of ECG to derive respiration without degradation of the obtained estimates, so it is possible to have reliable respiration rate estimates from just the PPG signal.
Collapse
Affiliation(s)
- Jesús Lázaro
- Communications Technology Group, Aragón Institute of Engineering Research, IIS Aragón, Universidad de Zaragoza, Zaragoza, Spain.
| | | | | | | | | |
Collapse
|
45
|
Monasterio V, Burgess F, Clifford GD. Robust classification of neonatal apnoea-related desaturations. Physiol Meas 2012; 33:1503-16. [PMID: 22902971 DOI: 10.1088/0967-3334/33/9/1503] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Respiratory signals monitored in the neonatal intensive care units are usually ignored due to the high prevalence of noise and false alarms (FA). Apneic events are generally therefore indicated by a pulse oximeter alarm reacting to the subsequent desaturation. However, the high FA rate in the photoplethysmogram may desensitize staff, reducing the reaction speed. The main reason for the high FA rates of critical care monitors is the unimodal analysis behaviour. In this work, we propose a multimodal analysis framework to reduce the FA rate in neonatal apnoea monitoring. Information about oxygen saturation, heart rate, respiratory rate and signal quality was extracted from electrocardiogram, impedance pneumogram and photoplethysmographic signals for a total of 20 features in the 5 min interval before a desaturation event. 1616 desaturation events from 27 neonatal admissions were annotated by two independent reviewers as true (physiologically relevant) or false (noise-related). Patients were divided into two independent groups for training and validation, and a support vector machine was trained to classify the events as true or false. The best classification performance was achieved on a combination of 13 features with sensitivity, specificity and accuracy of 100% in the training set, and a sensitivity of 86%, a specificity of 91% and an accuracy of 90% in the validation set.
Collapse
Affiliation(s)
- Violeta Monasterio
- CIBER de Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza, Spain.
| | | | | |
Collapse
|
46
|
Li Q, Clifford GD. Dynamic time warping and machine learning for signal quality assessment of pulsatile signals. Physiol Meas 2012; 33:1491-501. [PMID: 22902950 DOI: 10.1088/0967-3334/33/9/1491] [Citation(s) in RCA: 167] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In this work, we describe a beat-by-beat method for assessing the clinical utility of pulsatile waveforms, primarily recorded from cardiovascular blood volume or pressure changes, concentrating on the photoplethysmogram (PPG). Physiological blood flow is nonstationary, with pulses changing in height, width and morphology due to changes in heart rate, cardiac output, sensor type and hardware or software pre-processing requirements. Moreover, considerable inter-individual and sensor-location variability exists. Simple template matching methods are therefore inappropriate, and a patient-specific adaptive initialization is therefore required. We introduce dynamic time warping to stretch each beat to match a running template and combine it with several other features related to signal quality, including correlation and the percentage of the beat that appeared to be clipped. The features were then presented to a multi-layer perceptron neural network to learn the relationships between the parameters in the presence of good- and bad-quality pulses. An expert-labeled database of 1055 segments of PPG, each 6 s long, recorded from 104 separate critical care admissions during both normal and verified arrhythmic events, was used to train and test our algorithms. An accuracy of 97.5% on the training set and 95.2% on test set was found. The algorithm could be deployed as a stand-alone signal quality assessment algorithm for vetting the clinical utility of PPG traces or any similar quasi-periodic signal.
Collapse
Affiliation(s)
- Q Li
- Institute of Biomedical Engineering, School of Medicine, Shandong University, Jinan, Shandong 250012, People's Republic of China
| | | |
Collapse
|
47
|
Bravi A, Longtin A, Seely AJE. Review and classification of variability analysis techniques with clinical applications. Biomed Eng Online 2011; 10:90. [PMID: 21985357 PMCID: PMC3224455 DOI: 10.1186/1475-925x-10-90] [Citation(s) in RCA: 143] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2011] [Accepted: 10/10/2011] [Indexed: 11/20/2022] Open
Abstract
Analysis of patterns of variation of time-series, termed variability analysis, represents a rapidly evolving discipline with increasing applications in different fields of science. In medicine and in particular critical care, efforts have focussed on evaluating the clinical utility of variability. However, the growth and complexity of techniques applicable to this field have made interpretation and understanding of variability more challenging. Our objective is to provide an updated review of variability analysis techniques suitable for clinical applications. We review more than 70 variability techniques, providing for each technique a brief description of the underlying theory and assumptions, together with a summary of clinical applications. We propose a revised classification for the domains of variability techniques, which include statistical, geometric, energetic, informational, and invariant. We discuss the process of calculation, often necessitating a mathematical transform of the time-series. Our aims are to summarize a broad literature, promote a shared vocabulary that would improve the exchange of ideas, and the analyses of the results between different studies. We conclude with challenges for the evolving science of variability analysis.
Collapse
Affiliation(s)
- Andrea Bravi
- Department of Cellular and Molecular Medicine, University of Ottawa, Ottawa, Ontario, Canada.
| | | | | |
Collapse
|
48
|
Sepúlveda-Cano LM, Gil E, Laguna P, Castellanos-Dominguez G. Sleep apnoea detection in children using PPG envelope-based dynamic features. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2011; 2011:1483-1486. [PMID: 22254600 DOI: 10.1109/iembs.2011.6090362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Photopletysmography signal has been developed for monitoring of Obstructive Sleep Apnoea, in particular, whenever an apneic episode occurs, that is reflected by decreases in the photopletysmography signal amplitude fluctuation. However, other physiological events such as artifacts and deep inspiratory gasp produce sympathetic activation, being unrelated to apnea. Thus, its high sensitivity can produce misdetections and overestimate apneic episodes. In this regard, a methodology for selecting a set of relevant non-stationary features to increase the specificity of the obstructive sleep apnea detector is discussed. A time-evolving version of the standard linear multivariate decomposition is discussed to perform stochastic dimensionality reduction. As a result, performed outcomes of accuracy bring enough evidence that if using a subset of cepstral-based dynamic features, then patient classification accuracy is 83.3%. Therefore, photoplethysmography--based detection provides an adequate scheme for obstructive sleep apnea diagnosis.
Collapse
Affiliation(s)
- L M Sepúlveda-Cano
- Signal Processing and Recognition Group, Universidad Nacional de Colombia, sede Manizales.
| | | | | | | |
Collapse
|
49
|
Gil E, Orini M, Bailón R, Vergara JM, Mainardi L, Laguna P. Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions. Physiol Meas 2010; 31:1271-90. [PMID: 20702919 DOI: 10.1088/0967-3334/31/9/015] [Citation(s) in RCA: 239] [Impact Index Per Article: 17.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|