1
|
Gil A, Navarro R, Quintero P, Mares A. Transient Performance Analysis of Centrifugal Left Ventricular Assist Devices Coupled With Windkessel Model: Large Eddy Simulations Study on Continuous and Pulsatile Flow Operation. J Biomech Eng 2024; 146:101008. [PMID: 38683061 DOI: 10.1115/1.4065418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 04/25/2024] [Indexed: 05/01/2024]
Abstract
Computational fluid dynamics (CFD) simulations are widely used to develop and analyze blood-contacting medical devices such as left ventricular assist devices (LVADs). This work presents an analysis of the transient behavior of two centrifugal LVADs with different designs: HeartWare VAD and HeartMate3. A scale-resolving methodology is followed through Large Eddy Simulations, which allows for the visualization of turbulent structures. The three-dimensional (3D) LVAD models are coupled to a zero-dimensional (0D) 2-element Windkessel model, which accounts for the vascular resistance and compliance of the arterial system downstream of the device. Furthermore, both continuous- and pulsatile-flow operation modes are analyzed. For the pulsatile conditions, the artificial pulse of HeartMate3 is imposed, leading to a larger variation of performance variables in HeartWare VAD than in HeartMate3. Moreover, CFD results of pulsatile-flow simulations are compared to those obtained by accessing the quasi-steady maps of the pumps. The quasi-steady approach is a predictive tool used to provide a preliminary approximation of the pulsatile evolution of flow rate, pressure head, and power, by only imposing a speed pulse and vascular parameters. This preliminary quasi-steady solution can be useful for deciding the characteristics of the pulsatile speed law before running a transient CFD simulation, as the former entails a significant reduction in computational cost in comparison to the latter.
Collapse
Affiliation(s)
- Antonio Gil
- Clean Mobility & Thermofluids, Universitat Politècnica de València, Camino de Vera, s/n, València 46022, Spain
| | - Roberto Navarro
- Clean Mobility & Thermofluids, Universitat Politècnica de València, Camino de Vera, s/n, València 46022, Spain
| | - Pedro Quintero
- Clean Mobility & Thermofluids, Universitat Politècnica de València, Camino de Vera, s/n, València 46022, Spain
- Universitat Politècnica de València
| | - Andrea Mares
- Clean Mobility & Thermofluids, Universitat Politècnica de València, Camino de Vera, s/n, València 46022, Spain
| |
Collapse
|
2
|
Wu P, Zhang KJ, Xiang WJ, Du GT. Turbulent flow field in maglev centrifugal blood pumps of CH-VAD and HeartMate III: secondary flow and its effects on pump performance. Biomech Model Mechanobiol 2024:10.1007/s10237-024-01855-1. [PMID: 38822142 DOI: 10.1007/s10237-024-01855-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Accepted: 04/24/2024] [Indexed: 06/02/2024]
Abstract
Secondary flow path is one of the crucial aspects during the design of centrifugal blood pumps. Small clearance size increases stress level and blood damage, while large clearance size can improve blood washout and reduce stress level. Nonetheless, large clearance also leads to strong secondary flows, causing further blood damage. Maglev blood pumps rely on magnetic force to achieve rotor suspension and allow more design freedom of clearance size. This study aims to characterize turbulent flow field and secondary flow as well as its effects on the primary flow and pump performance, in two representative commercial maglev blood pumps of CH-VAD and HeartMate III, which feature distinct designs of secondary flow path. The narrow and long secondary flow path of CH-VAD resulted in low secondary flow rates and low disturbance to the primary flow. The flow loss and blood damage potential of the CH-VAD mainly occurred at the secondary flow path, as well as the blade clearances. By contrast, the wide clearances in HeartMate III induced significant disturbance to the primary flow, resulting in large incidence angle, strong secondary flows and high flow loss. At higher flow rates, the incidence angle was even larger, causing larger separation, leading to a significant decrease of efficiency and steeper performance curve compared with CH-VAD. This study shows that maglev bearings do not guarantee good blood compatibility, and more attention should be paid to the influence of secondary flows on pump performance when designing centrifugal blood pumps.
Collapse
Affiliation(s)
- Peng Wu
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing, China.
- Artificial Organ Technology Laboratory, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China.
| | - Ke-Jia Zhang
- Artificial Organ Technology Laboratory, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Wen-Jing Xiang
- Artificial Organ Technology Laboratory, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Guan-Ting Du
- Artificial Organ Technology Laboratory, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| |
Collapse
|
3
|
Lv S, He ZP, Liu GM, Hu SS. A multi-constituent model for assessing the effect of impeller shroud on the thrombosis potential of a centrifugal blood pump. Int J Artif Organs 2024; 47:269-279. [PMID: 38506302 DOI: 10.1177/03913988241239456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/21/2024]
Abstract
Centrifugal blood pumps can be used for treating heart failure patients. However, pump thrombosis has remained one of the complications that trouble clinical treatment. This study analyzed the effect of impeller shroud on the thrombosis risk of the blood pump, and predicted areas prone to thrombosis. Multi-constituent transport equations were presented, considering mechanical activation and biochemical activation. It was found that activated platelets concentration can increase with shear stress and adenosine diphosphate(ADP) concentration increasing, and the highest risk of thrombosis inside the blood pump was under extracorporeal membrane oxygenation (ECMO) mode. Under the same condition, ADP concentration and thrombosis index of semi-shroud impeller can increase by 7.3% and 7.2% compared to the closed-shroud impeller. The main reason for the increase in thrombosis risk was owing to elevated scalar shear stress and more coagulation promoting factor-ADP released. The regions with higher thrombosis potential were in the center hole, top and bottom clearance. As a novelty, the findings revealed that impeller shroud can influence mechanical and biochemical activation factors. It is useful for identifying potential risk regions of thrombus formation based on relative comparisons.
Collapse
Affiliation(s)
- Shen Lv
- Shenzhen Key Laboratory of Cardiovascular Disease, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, Shenzhen, Guangdong Province, China
| | - Zhi-Peng He
- Shenzhen Key Laboratory of Cardiovascular Disease, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, Shenzhen, Guangdong Province, China
| | - Guang-Mao Liu
- Shenzhen Key Laboratory of Cardiovascular Disease, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, Shenzhen, Guangdong Province, China
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Sheng-Shou Hu
- Shenzhen Key Laboratory of Cardiovascular Disease, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, Shenzhen, Guangdong Province, China
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
4
|
Nascimbene A, Bark D, Smadja DM. Hemocompatibility and biophysical interface of left ventricular assist devices and total artificial hearts. Blood 2024; 143:661-672. [PMID: 37890145 PMCID: PMC10900168 DOI: 10.1182/blood.2022018096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 09/18/2023] [Accepted: 09/20/2023] [Indexed: 10/29/2023] Open
Abstract
ABSTRACT Over the past 2 decades, there has been a significant increase in the utilization of long-term mechanical circulatory support (MCS) for the treatment of cardiac failure. Left ventricular assist devices (LVADs) and total artificial hearts (TAHs) have been developed in parallel to serve as bridge-to-transplant and destination therapy solutions. Despite the distinct hemodynamic characteristics introduced by LVADs and TAHs, a comparative evaluation of these devices regarding potential complications in supported patients, has not been undertaken. Such a study could provide valuable insights into the complications associated with these devices. Although MCS has shown substantial clinical benefits, significant complications related to hemocompatibility persist, including thrombosis, recurrent bleeding, and cerebrovascular accidents. This review focuses on the current understanding of hemostasis, specifically thrombotic and bleeding complications, and explores the influence of different shear stress regimens in long-term MCS. Furthermore, the role of endothelial cells in protecting against hemocompatibility-related complications of MCS is discussed. We also compared the diverse mechanisms contributing to the occurrence of hemocompatibility-related complications in currently used LVADs and TAHs. By applying the existing knowledge, we present, for the first time, a comprehensive comparison between long-term MCS options.
Collapse
Affiliation(s)
- Angelo Nascimbene
- Advanced Cardiopulmonary Therapies and Transplantation, University of Texas, Houston, TX
| | - David Bark
- Division of Hematology and Oncology, Department of Pediatrics, Washington University in St. Louis, St. Louis, MO
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO
| | - David M. Smadja
- Université de Paris-Cité, Innovative Therapies in Haemostasis, INSERM, Paris, France
- Hematology Department, Assistance Publique–Hôpitaux de Paris, Georges Pompidou European Hospital, Paris, France
| |
Collapse
|
5
|
Bletsos G, Rung T, Radtke L. Hemodynamics in arterial bypass graft anastomoses with varying cuff sizes and proximal flow paths: a fluid-structure interaction study. Comput Methods Biomech Biomed Engin 2024:1-20. [PMID: 38323804 DOI: 10.1080/10255842.2024.2310747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2023] [Accepted: 12/29/2023] [Indexed: 02/08/2024]
Abstract
This article investigates the effect of the cuff size of arterial bypass grafts and the flow conditions on the hemodynamics in the anastomosis (connection) to the artery, using numerical simulations. We consider a fluid-structure interaction problem which is solved based on a partitioned scheme. Additionally, we employ computational fluid dynamics to investigate the effect of a rigid wall assumption. The work focuses on clinically relevant hemodynamic quantities associated with the development of intimal hyperplasia. We also include a model for the prediction of hemolysis into the simulation. The results show that even minor changes of the cuff size can result into significant differences in the corresponding quantities of interest. The importance of the inflow path is shown to be lower than that of the cuff size. The usually employed rigid wall assumption is found to be adequate to address wall shear stress oscillations but falls short on predicting maximum and minimum wall shear stress-related quantities of interest.
Collapse
Affiliation(s)
- Georgios Bletsos
- Institute for Fluid Dynamics and Ship Theory (M-8), Hamburg University of Technology, Hamburg, Germany
| | - Thomas Rung
- Institute for Fluid Dynamics and Ship Theory (M-8), Hamburg University of Technology, Hamburg, Germany
| | - Lars Radtke
- Institute for Ship Structural Design and Analysis (M-10), Hamburg University of Technology, Hamburg, Germany
| |
Collapse
|
6
|
Huo M, Giridharan GA, Sethu P, Qu P, Qin K, Wang Y. Numerical simulation analysis of multi-scale computational fluid dynamics on hemodynamic parameters modulated by pulsatile working modes for the centrifugal and axial left ventricular assist devices. Comput Biol Med 2024; 169:107788. [PMID: 38091724 DOI: 10.1016/j.compbiomed.2023.107788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 11/08/2023] [Accepted: 11/28/2023] [Indexed: 02/08/2024]
Abstract
Continuous flow (CF) left ventricular assist devices (LVAD) operate at a constant speed mode, which could result in increased risk of adverse events due to reduced vascular pulsatility. Consequently, pump speed modulation algorithms have been proposed to augment vascular pulsatility. However, the quantitative local hemodynamic effects on the aorta when the pump is operating with speed modulation using different types of CF-LVADs are still under investigation. The computational fluid dynamics (CFD) study was conducted to quantitatively elucidate the hemodynamic effects on a clinical patient-specific aortic model under different speed patterns of CF-LVADs. Pressure distribution, wall shear stress (WSS), time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), and velocity were calculated to compare their differences at constant and pulsatile speeds under centrifugal and axial LVAD support. Results showed that pulse pressure on the aorta was significantly larger under pulsatile speed mode than that under constant speed mode for both CF-LVADs, indicating enhanced aorta pulsatility, as well as the higher peak blood flow velocity on some representative slices of aorta. Pulsatile speed modulation enhanced peak WSS compared to constant speed; high TAWSS region appeared near the branch of left common carotid artery and distal aorta regardless of speed modes and CF-LVADs but these regions also had low OSI; RRT was almost the same for all the cases. This study may provide a basis for the scientific and reasonable selection of the pulsatile speed patterns of CF-LVADs for treating heart failure patients.
Collapse
Affiliation(s)
- Mingming Huo
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| | | | - Palaniappan Sethu
- Division of Cardiovascular Disease, Department of Medicine, School of Medicine and Department of Biomedical Engineering, School of Engineering, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Peng Qu
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian, China
| | - Kairong Qin
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian, China
| | - Yu Wang
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian, China.
| |
Collapse
|
7
|
Oran E, Abo-Serie E, Jewkes J, Henry M, Oran B. Design and optimisation of an Intra-Aortic Shrouded rotor axial pump. J Biomech 2024; 162:111858. [PMID: 37989028 DOI: 10.1016/j.jbiomech.2023.111858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 10/27/2023] [Accepted: 11/01/2023] [Indexed: 11/23/2023]
Abstract
Undesirable side effects in patients with a LVAD (Left Ventricular Assist Device) pump fitted include blood damage, thrombosis, blood traumatisation, and End-Organ Disfunctions. These side effects have generally been attributed to the high wall shear stresses and the induced turbulent flow. In this study, we introduce a novel design to address these effects by lowering the rotational speed and providing an optimum flow path design to minimise blood damage. We present an initial scheme for a new Intra-Aortic Shrouded Rotary Axial Pump and develop a sequence of pump geometries, for which the Taguchi Design Optimisation Method has been applied. We apply CFD tools to simulate the pressure rise, pump performance, hydraulic efficiency, wall shear stress, exposure time and mass flow rate. A prototype pump has been tested in a mock cardiovascular circuit using a water-glycerol solution. The optimum design delivered the desired pressure/mass flow rate characteristics at a significantly low rpm (2900 rpm). As a result, the estimated blood damage index is low, matching the design requirements. The theoretical performance was matched by experimental results.
Collapse
Affiliation(s)
- Elif Oran
- Coventry University, Centre for Fluid and Complex Systems, Coventry, UK
| | - Essam Abo-Serie
- University of Leicester, School of Engineering, Leicester, UK.
| | - James Jewkes
- University of Leicester, School of Engineering, Leicester, UK
| | - Manus Henry
- Coventry University, Centre for Fluid and Complex Systems, Coventry, UK; University of Oxford, Department of Engineering Science, Oxford, UK
| | - Bulent Oran
- Medicana International Hospital, Department of Pediatric Cardiology, Izmir, Turkey
| |
Collapse
|
8
|
Li C, Qiu H, Ma J, Wang Y. Numerical study on the performance of mixed flow blood pump with superhydrophobic surface. Med Biol Eng Comput 2023; 61:3103-3121. [PMID: 37656332 DOI: 10.1007/s11517-023-02880-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 04/13/2023] [Indexed: 09/02/2023]
Abstract
To meet the clinical status of the wide application of percutaneous mechanical circulatory support, this paper selects the mixed flow blood pump applied with superhydrophobic surface as the research object. The Navier slip model was used to simulate the slip characteristics of superhydrophobic surface, and the effects of the blade wrap angle and the superhydrophobic surface on the performance of the mixed flow blood pump are studied by numerical simulation. The results show that (1) considering the head, hydraulic efficiency, and hemolysis index of the blood pump, the optimal value of the blade wrap angle of the mixed flow blood pump in this paper is 60°. (2) The hydraulic efficiency of the blood pump with superhydrophobic surface is improved, and the maximum growth rate is about 13.9%; superhydrophobic surface can reduce the hemolysis index of blood pump under various working conditions, and the maximum reduction rate of hemolysis index of blood pump is 22.9%. (3) The variation trends of blood pump head, hydraulic efficiency, and hemolysis index with the increased rotating speed before and after setting superhydrophobic slip boundary conditions are the same as their original variation trends.
Collapse
Affiliation(s)
- Chengcheng Li
- Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Huihe Qiu
- Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, New Territories, Hong Kong
| | - Jianying Ma
- Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai, 200032, China
| | - Ying Wang
- Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
- Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, New Territories, Hong Kong.
| |
Collapse
|
9
|
Escher A, Thamsen B, Strauch C, Kertzscher U, Zimpfer D, Thamsen PU, Granegger M. In-Vitro Flow Validation of Third-Generation Ventricular Assist Devices: Feasibility and Challenges. ASAIO J 2023; 69:932-941. [PMID: 37418316 DOI: 10.1097/mat.0000000000002009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/09/2023] Open
Abstract
Computational fluid dynamics (CFD) is a powerful tool for the in-silico evaluation of rotodynamic blood pumps (RBPs). Corresponding validation, however, is typically restricted to easily accessible, global flow quantities. This study showcased the HeartMate 3 (HM3) to identify feasibility and challenges of enhanced in-vitro validation in third-generation RBPs. To enable high-precision acquisition of impeller torques and grant access for optical flow measurements, the HM3 testbench geometry was geometrically modified. These modifications were reproduced in silico , and global flow computations validated along 15 operating conditions. The globally validated flow in the testbench geometry was compared with CFD-simulated flows in the original geometry to assess the impact of the necessary modifications on global and local hydraulic properties. Global hydraulic properties in the testbench geometry were successfully validated (pressure head: r = 0.999, root mean square error [RMSE] = 2.92 mmHg; torque: r = 0.996, RMSE = 0.134 mNm). In-silico comparison with the original geometry demonstrated good agreement ( r > 0.999, relative errors < 11.97%) of global hydraulic properties. Local hydraulic properties (errors up to 81.78%) and hemocopatibility predictions (deviations up to 21.03%), however, were substantially affected by the geometric modifications. Transferability of local flow measures derived on advanced in-vitro testbenches toward original pump designs is challenged by significant local effects associated with the necessary geometrical modifications.
Collapse
Affiliation(s)
- Andreas Escher
- From the Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Bente Thamsen
- From the Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Carsten Strauch
- Department of Fluid System Dynamics, Technische Universität Berlin, Berlin, Germany
| | - Ulrich Kertzscher
- Deutsches Herzzentrum der Charité - Medical Heart Center of Charité and German Heart Institute Berlin, Institute of Computer-assisted Cardiovascular Medicine, Biofluid Mechanics Laboratory, Berlin, Germany
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Daniel Zimpfer
- From the Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
- Division of Cardiac Surgery, Department of Surgery, Medical University Graz, Graz, Austria
| | - Paul Uwe Thamsen
- Department of Fluid System Dynamics, Technische Universität Berlin, Berlin, Germany
| | - Marcus Granegger
- From the Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
- Deutsches Herzzentrum der Charité - Medical Heart Center of Charité and German Heart Institute Berlin, Institute of Computer-assisted Cardiovascular Medicine, Biofluid Mechanics Laboratory, Berlin, Germany
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| |
Collapse
|
10
|
Lv S, He ZP, Liu GM, Hu SS. Numerical investigation on the effect of impeller axial position on hemodynamics of an extracorporeal centrifugal blood pump. Comput Methods Biomech Biomed Engin 2023:1-12. [PMID: 37724774 DOI: 10.1080/10255842.2023.2256946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 09/01/2023] [Indexed: 09/21/2023]
Abstract
Extracorporeal centrifugal blood pumps are used to treat cardiogenic shock. Owing to the imbalanced excitation or initial assembly configurations, the variation in the impeller axial position has the potential to affect the blood pump performance. This study compared the hydrodynamics and hemolysis outcomes at different impeller axial positions via numerical simulations. The result shows that pressure difference of the blood pump decreased with increasing impeller axial position, with decreasing by 4.5% at a flow rate of 2 L/min. Under axial impeller motion close to the top pump casing, average wall shear stress and scalar shear stress reached their maximum values (64.2 and 29.1 Pa, respectively). The residence time in the impeller center hole and bottom clearance were extended to 0.5 s by increasing impeller axial position. Compared to the baseline blood pump, hemolysis index increased by 12.3% and 24.3% when impeller axial position is 2.5 and 4.0 mm, respectively. As a novelty, the findings reveal that the impeller axial position adversely affects hemolysis performance when the impeller is close to the pump casing. Therefore, in the development process of centrifugal blood pumps, the optimal axial position of the impeller must be defined to ensure hemodynamic performance.
Collapse
Affiliation(s)
- Shen Lv
- Shenzhen Key Laboratory of Cardiovascular Disease, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, Shenzhen, Guangdong Province, China
| | - Zhi-Peng He
- Shenzhen Key Laboratory of Cardiovascular Disease, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, Shenzhen, Guangdong Province, China
| | - Guang-Mao Liu
- Shenzhen Key Laboratory of Cardiovascular Disease, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, Shenzhen, Guangdong Province, China
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Sheng-Shou Hu
- Shenzhen Key Laboratory of Cardiovascular Disease, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, Shenzhen, Guangdong Province, China
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
11
|
Xue Q, Ren X, Gao B, Li S, Song Z, Ding J, Chang Y. Hemodynamic investigation of a novel rotary displacement blood pump for extracorporeal membrane oxygenation. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3705. [PMID: 37005088 DOI: 10.1002/cnm.3705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 03/12/2023] [Accepted: 03/19/2023] [Indexed: 06/07/2023]
Abstract
Extracorporeal membrane oxygenation (ECMO) is a life support system used in the treatment of severe respiratory and circulatory failure. High shear stress caused by the high rotational speed of centrifugal blood pumps can cause hemolysis and platelet activation, which are among the major factors leading to the complications of the ECMO system. In this study, a novel blood pump named rotary displacement blood pump (RDBP), which can considerably reduce rotational speed and shear stress while ensuring the normal pressure flow relationship, was proposed. We employed computational fluid dynamics (CFD) analysis to investigate the performance of RDBP under adult ECMO support operating conditions (5 L/min with 350 mmHg). The efficiency and H-Q curves of the RDBP were calculated to evaluate its hydraulic performance, and pressure, flow patterns, and shear stress distribution were analyzed to estimate the hemodynamic characteristics in the pump. In addition, the modified index of hemolysis (MIH) was calculated for the RDBP based on a Eulerian approach. The hydraulic efficiency of the RDBP was 47.28%. The velocity distribution of flow field in the pump was relatively uniform. Most of the liquid (more than 75%) in the pump was exposed to low scale shear stress (<1 Pa), which was close to normal physiological conditions. The gap area was the main distribution location of high scale shear stress. The high wall shear stress (>9 Pa) volume fraction of the RDBP was small and located in the boundary areas between the rotor's edge and the housing. The MIH value of the RDBP was 9.87 ± 0.93 (mean ± SD). The RDBP can achieve better hydraulic efficiency and hemodynamic performance at lower rotational speed. The design of this novel pump is expected to provide a new direction for developing a blood pump for ECMO.
Collapse
Affiliation(s)
- Qingxin Xue
- Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China
| | - Xiaoyu Ren
- Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China
| | - Bin Gao
- Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China
| | - Shu Li
- National Institutes for Food and Drug Control, Institute for Medical Device Control, Beijing, China
| | - Zhiming Song
- Department of Cardiac Surgery, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China
| | - Jinli Ding
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Yu Chang
- National Clinical Research Center for Child Health, The Children's Hospital Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
12
|
Gao X, Xu Z, Chen C, Hao P, He F, Zhang X. Full-scale numerical simulation of hemodynamics based on left ventricular assist device. Front Physiol 2023; 14:1192610. [PMID: 37304828 PMCID: PMC10248007 DOI: 10.3389/fphys.2023.1192610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Accepted: 05/16/2023] [Indexed: 06/13/2023] Open
Abstract
Ventricular assist devices have been widely used and accepted to treat patients with end-stage heart failure. The role of VAD is to improve circulatory dysfunction or temporarily maintain the circulatory status of patients. In order to be closer to the medical practice, a multi-Domain model of the left ventricular coupled axial flow artificial heart was considered to study the effect of its hemodynamics on the aorta. Because whether LVAD itself was connected between the left ventricular apex and the ascending aorta by catheter in the loop was not very important for the analysis of simulation results, on the premise of ensuring the multi-Domain simulation, the simulation data of the import and export ends of LVAD were imported to simplify the model. In this paper, the hemodynamic parameters in the ascending aorta, such as blood flow velocity vector, wall shear stress distribution, vorticity current intensity, vorticity flow generation, etc., have been calculated. The numerical conclusion of this study showed the vorticity intensity under LVAD was significantly higher than that under patients' conditions and the overall condition is similar to that of a healthy ventricular spin, which can improve heart failure patients' condition while minimizing other pitfalls. In addition, high velocity blood flow during left ventricular assist surgery is mainly concentrated near the lining of the ascending aorta lumen. What's more, the paper proposes to use Q criterion to determine the generation of vorticity flow. The Q criterion of LVAD is much higher than that of patients with heart failure, and the closer the LVAD is to the wall of the ascending aorta, the greater the Q criterion is. All these are beneficial to the effectiveness of LVAD in the treatment of heart failure patients and provide clinical suggestions for the LVAD implantation in clinical practice.
Collapse
Affiliation(s)
- Xinyi Gao
- Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China
| | - Zhike Xu
- Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China
| | - Chenghan Chen
- Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China
| | - Pengfei Hao
- Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China
- Tsinghua University (School of Materials Science and Engineering)—AVIC Aerodynamics Research Institute Joint Research Center for Advanced Materials and Anti-Icing, Beijing, China
| | - Feng He
- Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China
| | - Xiwen Zhang
- Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China
| |
Collapse
|
13
|
Yun Z, Yao J, Wang L, Tang X, Feng Y. The design and evaluation of the outflow structures of an interventional microaxial blood pump. Front Physiol 2023; 14:1169905. [PMID: 37250127 PMCID: PMC10213901 DOI: 10.3389/fphys.2023.1169905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Accepted: 05/04/2023] [Indexed: 05/31/2023] Open
Abstract
Blood pump design efforts are focused on enhancing hydraulic effectiveness and minimizing shear stress. Unlike conventional blood pumps, interventional microaxial blood pumps have a unique outflow structure due to minimally invasive technology. The outflow structure, composed of the diffuser and cage bridges, is crucial in minimizing the pump size to provide adequate hemodynamic support. This study proposed four outflow structures of an interventional microaxial blood pump depending on whether the diffuser with or without blades and cage bridges were straight or curved. The outflow flow structure's effect on the blood pump's hydraulic performance and shear stress distribution was evaluated by computational fluid dynamics and hydraulic experiments. The results showed that all four outflow structures could achieve the pressure and flow requirements specified at the design point but with significant differences in shear stress distribution. Among them, the outflow structure with curved bridges would make the blood dispersed more evenly when flowing out of the pump, which could effectively reduce the shear stress at the cage bridges. The outflow structure with blades would aggravate the secondary flow at the leading edge of the impeller, increasing the risk of flow stagnation. The combination of curved bridges and the bladeless diffuser had a relatively better shear stress distribution, with the proportion of fluid exposed to low scalar shear stress (<50 Pa) and high scalar shear stress (>150 Pa) in the blood pump being 97.92% and 0.26%, respectively. It could be concluded that the outflow structure with curved bridges and bladeless diffuser exhibited relatively better shear stress distribution and a lower hemolysis index of 0.00648%, which could support continued research on optimizing the microaxial blood pumps.
Collapse
Affiliation(s)
- Zhong Yun
- *Correspondence: Zhong Yun, ; Jinfu Yao,
| | - Jinfu Yao
- *Correspondence: Zhong Yun, ; Jinfu Yao,
| | | | | | | |
Collapse
|
14
|
Bornoff J, Najar A, Fresiello L, Finocchiaro T, Perkins IL, Gill H, Cookson AN, Fraser KH. Fluid-structure interaction modelling of a positive-displacement Total Artificial Heart. Sci Rep 2023; 13:5734. [PMID: 37059748 PMCID: PMC10104863 DOI: 10.1038/s41598-023-32141-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 03/23/2023] [Indexed: 04/16/2023] Open
Abstract
For those suffering from end-stage biventricular heart failure, and where a heart transplantation is not a viable option, a Total Artificial Heart (TAH) can be used as a bridge to transplant device. The Realheart TAH is a four-chamber artificial heart that uses a positive-displacement pumping technique mimicking the native heart to produce pulsatile flow governed by a pair of bileaflet mechanical heart valves. The aim of this work was to create a method for simulating haemodynamics in positive-displacement blood pumps, using computational fluid dynamics with fluid-structure interaction to eliminate the need for pre-existing in vitro valve motion data, and then use it to investigate the performance of the Realheart TAH across a range of operating conditions. The device was simulated in Ansys Fluent for five cycles at pumping rates of 60, 80, 100 and 120 bpm and at stroke lengths of 19, 21, 23 and 25 mm. The moving components of the device were discretised using an overset meshing approach, a novel blended weak-strong coupling algorithm was used between fluid and structural solvers, and a custom variable time stepping scheme was used to maximise computational efficiency and accuracy. A two-element Windkessel model approximated a physiological pressure response at the outlet. The transient outflow volume flow rate and pressure results were compared against in vitro experiments using a hybrid cardiovascular simulator and showed good agreement, with maximum root mean square errors of 15% and 5% for the flow rates and pressures respectively. Ventricular washout was simulated and showed an increase as cardiac output increased, with a maximum value of 89% after four cycles at 120 bpm 25 mm. Shear stress distribution over time was also measured, showing that no more than [Formula: see text]% of the total volume exceeded 150 Pa at a cardiac output of 7 L/min. This study showed this model to be both accurate and robust across a wide range of operating points, and will enable fast and effective future studies to be undertaken on current and future generations of the Realheart TAH.
Collapse
Affiliation(s)
- Joseph Bornoff
- Department of Mechanical Engineering, University of Bath, Bath, UK
| | - Azad Najar
- Scandinavian Real Heart AB, Västerås, Sweden
| | - Libera Fresiello
- Faculty of Science and Technology, University of Twente, Twente, The Netherlands
| | | | | | - Harinderjit Gill
- Department of Mechanical Engineering, University of Bath, Bath, UK
- Centre for Therapeutic Innovation, University of Bath, Bath, UK
| | - Andrew N Cookson
- Department of Mechanical Engineering, University of Bath, Bath, UK
- Centre for Therapeutic Innovation, University of Bath, Bath, UK
| | - Katharine H Fraser
- Department of Mechanical Engineering, University of Bath, Bath, UK.
- Centre for Therapeutic Innovation, University of Bath, Bath, UK.
| |
Collapse
|
15
|
Gao Y, Li M, Jiang M, Zhang Y, Wu C, Ji X. Hemolysis performance analysis and a novel estimation model of roller pump system. Comput Biol Med 2023; 159:106842. [PMID: 37062254 DOI: 10.1016/j.compbiomed.2023.106842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 03/14/2023] [Accepted: 03/30/2023] [Indexed: 04/18/2023]
Abstract
OBJECTIVE Hemolysis performance is a crucial criterion for roller pumps utilized in life supporting system. In this study, the factor of hemolysis for roller pumps was selected as the target, and an estimation formulation was built to evaluate its hemolysis. METHODS Several models were proposed and then simulated with the assistant of Computational fluid dynamics (CFD) framework. The hemolysis performance was calculated using the power law model based on CFD and the estimation model in accordance with geometry parameters proposed in this study. The results of the in vitro experiments were compared with the simulation results. Power law model with the lowest error was utilized in following analysis. RESULTS As indicated by the simulation result, the rotary speed most significantly affected the hemolysis performance of roller blood pumps, followed by roller number and diameter of tube. The index of hemolysis (IH) for roller blood pumps at a rotary speed of 20-100 rpm ranged from 8.73E-7 to 8.07E-5. The relative error of the estimation model (4.93%) was lower than of the power law model (6.78%). CONCLUSION The IH led by pumps shows a significant, nonlinear relationship with the rotary speed. The design of multiple rollers design is harmful for hemolysis performance and larger diameter of tube exhibits decreased hemolysis at constant flow rate. An estimation formula was proposed with lower relative error for roller pump with the same shell set, which exhibited reduced computation and elevated convenience. And it can be utilized in hemolysis estimation of roller pumps potentially.
Collapse
Affiliation(s)
- Yuan Gao
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, 100191, China; Research Institute for Frontier Science, Beihang University, Beijing, 100191, China
| | - Ming Li
- China-America Institute of Neuroscience, Xuanwu Hospital, Capital Medical University, Beijing, 100053, China
| | - Miaowen Jiang
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, 100191, China; Research Institute for Frontier Science, Beihang University, Beijing, 100191, China
| | - Yang Zhang
- China-America Institute of Neuroscience, Xuanwu Hospital, Capital Medical University, Beijing, 100053, China; Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing, 100053, China
| | - Chuanjie Wu
- China-America Institute of Neuroscience, Xuanwu Hospital, Capital Medical University, Beijing, 100053, China; Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing, 100053, China
| | - Xunming Ji
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, 100191, China; Research Institute for Frontier Science, Beihang University, Beijing, 100191, China; China-America Institute of Neuroscience, Xuanwu Hospital, Capital Medical University, Beijing, 100053, China; Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing, 100053, China.
| |
Collapse
|
16
|
Li Y, Wang H, Xi Y, Sun A, Wang L, Deng X, Chen Z, Fan Y. A mathematical model for assessing shear induced bleeding risk. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 231:107390. [PMID: 36745955 DOI: 10.1016/j.cmpb.2023.107390] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 01/16/2023] [Accepted: 01/30/2023] [Indexed: 06/18/2023]
Abstract
PURPOSE The objective of this study is to develop a bleeding risk model for assessing device-induced bleeding risk in patients supported with blood contact medical devices (BCMDs). METHODS The mathematical model for evaluating bleeding risk considers the effects of shear stress on von Willebrand factor (vWF) unfolding, high molecular weight multimers-vWF (HMWM-vWF) degradation, platelet activation and receptor shedding and platelet-vWF binding ability. Functions of the effect of shear stress on the above factors are fitted/employed and solved by the Eulerian transport equation. An axial flow-through Couette device and two clinical VADs which are HeartWare Ventricular Assist Device (HVAD) and HeartMate II (HM II) blood pump were employed to perform the simulation to evaluate platelet receptor shedding (GPIbα and GPIIb/IIIa), loss of HWMW-vWF, platelet-vWF binding ability and bleeding risk for validating the accuracy of our model. RESULTS The platelet-vWF binding ability after being subjected to high shear region in the axial flow-through Couette device predicted by our bleeding model was highly consistent with reported experimental data. As indicated by our CFD simulation results in the axial flow-through Couette device, it can find that an increase in shear stress led to a decrease in the adhesion ability of platelets on vWF, while the binding ability of vWF with platelets first increase and then decrease as shear stress elevates gradually beyond a threshold. The factor of exposure time can enhance the effect of shear stress. Additionally, the shear-induced bleeding risk predicted by our model increases with increasing shear stress and exposure time in an axial flow-through Couette device. As indicated by our numerical model, the bleeding risk in HVAD was higher than HMII, which is highly consistent with the meta-analysis based on clinical statistics. Our simulation investigations in these two clinical VADs also found that HVAD caused a higher rate of platelet receptor shedding and lower damage to HWMW-vWF than HeartMate II. The high shear stress generated in the narrow and turbulent regions of both VADs was the underlying cause of device-induced bleeding. CONCLUSION In this study, the shear-induced bleeding risk predicted by our bleeding model in axial flow-through Couette device and two clinical VADs is consistent or highly correlated with experimental and clinical findings, which proves the accuracy of our bleeding model. Our bleeding model can be used to aid the development of new BCMDs with improved functional characteristics and biocompatibility, and help to reduce risk of device-induced adverse events in patients.
Collapse
Affiliation(s)
- Yuan Li
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Hongyu Wang
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Yifeng Xi
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Anqiang Sun
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Lizhen Wang
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Xiaoyan Deng
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Zengsheng Chen
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China.
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China.
| |
Collapse
|
17
|
Popovich KD, Vagner SA, Murashko DT, Ten GN, Ryabkin DI, Savelyev MS, Kitsyuk EP, Gerasimenko EA, Edelbekova P, Konovalov AN, Telyshev DV, Selishchev SV, Gerasimenko AY. Stability and Thrombogenicity Analysis of Collagen/Carbon Nanotube Nanocomposite Coatings Using a Reversible Microfluidic Device. MEMBRANES 2023; 13:403. [PMID: 37103830 PMCID: PMC10144663 DOI: 10.3390/membranes13040403] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 03/27/2023] [Accepted: 03/30/2023] [Indexed: 06/19/2023]
Abstract
Currently, the development of stable and antithrombogenic coatings for cardiovascular implants is socially important. This is especially important for coatings exposed to high shear stress from flowing blood, such as those on ventricular assist devices. A method of layer-by-layer formation of nanocomposite coatings based on multi-walled carbon nanotubes (MWCNT) in a collagen matrix is proposed. A reversible microfluidic device with a wide range of flow shear stresses has been developed for hemodynamic experiments. The dependence of the resistance on the presence of a cross-linking agent for collagen chains in the composition of the coating was demonstrated. Optical profilometry determined that collagen/c-MWCNT and collagen/c-MWCNT/glutaraldehyde coatings obtained sufficiently high resistance to high shear stress flow. However, the collagen/c-MWCNT/glutaraldehyde coating was almost twice as resistant to a phosphate-buffered solution flow. A reversible microfluidic device made it possible to assess the level of thrombogenicity of the coatings by the level of blood albumin protein adhesion to the coatings. Raman spectroscopy demonstrated that the adhesion of albumin to collagen/c-MWCNT and collagen/c-MWCNT/glutaraldehyde coatings is 1.7 and 1.4 times lower than the adhesion of protein to a titanium surface, widely used for ventricular assist devices. Scanning electron microscopy and energy dispersive spectroscopy determined that blood protein was least detected on the collagen/c-MWCNT coating, which contained no cross-linking agent, including in comparison with the titanium surface. Thus, a reversible microfluidic device is suitable for preliminary testing of the resistance and thrombogenicity of various coatings and membranes, and nanocomposite coatings based on collagen and c-MWCNT are suitable candidates for the development of cardiovascular devices.
Collapse
Affiliation(s)
- Kristina D. Popovich
- Institute for Bionic Technologies and Engineering, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street 2-4, 119435 Moscow, Russia
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| | - Sergey A. Vagner
- Institute for Bionic Technologies and Engineering, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street 2-4, 119435 Moscow, Russia
| | - Denis T. Murashko
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| | - Galina N. Ten
- Department of Physics, Saratov State University, Astrakhanskaya Street 83, 410012 Saratov, Russia
| | - Dmitry I. Ryabkin
- Institute for Bionic Technologies and Engineering, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street 2-4, 119435 Moscow, Russia
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| | - Mikhail S. Savelyev
- Institute for Bionic Technologies and Engineering, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street 2-4, 119435 Moscow, Russia
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| | - Evgeny P. Kitsyuk
- Scientific-Manufacturing Complex “Technological Centre”, Shokin Square 1, bld. 7 off. 7237, 124498 Moscow, Russia
| | - Ekaterina A. Gerasimenko
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
- Orthopedic Department, State Autonomous Institution of Health of the City of Moscow, Dental Clinic No.35, Building 1638, Zelenograd, 124365 Moscow, Russia
| | - Polina Edelbekova
- Insitute of Nanotechnology of Microelectronics of the Russian Academy of Sciences, 32a Leninsky Av., 119991 Moscow, Russia
| | | | - Dmitry V. Telyshev
- Institute for Bionic Technologies and Engineering, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street 2-4, 119435 Moscow, Russia
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| | - Sergey V. Selishchev
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| | - Alexander Yu. Gerasimenko
- Institute for Bionic Technologies and Engineering, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street 2-4, 119435 Moscow, Russia
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| |
Collapse
|
18
|
Li S, Jin D, Gui X, Liu G, Jiang X. Numerical analysis of different cardiac functions and support modes on blood damage potential in an axial pump. Int J Artif Organs 2023; 46:215-225. [PMID: 36941753 DOI: 10.1177/03913988231155938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/23/2023]
Abstract
BACKGROUND Cardiac functions and support modes of left ventricular assist device (LVAD) will influence the pump inner flow field and blood damage potential. METHODS Computational fluid dynamics (CFD) method and lumped-parameter-model (LPM) were applied to investigate the impacts of cardiac functions under full (9000 rpm) and partial (8000 rpm) support modes in an axial pump. RESULTS The constitution of hemolysis index (HI) in different components of the pump was investigated. HI was found to be more sensitive to positive incidence angles (i) compared with negative incidence angles in rotors. Negative incidence angles had little impact on HI both in rotors and the outlet guide vanes. The improved cardiac function made only a minor difference in HIave (estimated average HI in one cardiac cycle) by 9.88%, as the flow rate expanded mainly to higher flow range. Switching to partial support mode, however, would induce a periodic experience of severe flow separation and recirculation at low flow range. This irregular flow field increased HIave by 47.97%, remarkably increasing the blood damage potential. CONCLUSION This study revealed the relationship between the blade incidence angle i and HI, and recommended negative-incidence-angle blade designs as it yielded lower HI. Moreover, to avoid flow range below 50% of the design point, careful evaluations should be made before switching support modes as weaning procedures in clinical applications.
Collapse
Affiliation(s)
- Shulei Li
- School of Energy and Power Engineering, Beihang University, Beijing, China
| | - Donghai Jin
- School of Energy and Power Engineering, Beihang University, Beijing, China
| | - Xingmin Gui
- School of Energy and Power Engineering, Beihang University, Beijing, China
| | - Guangmao Liu
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Xihang Jiang
- Beijing Power Machinery Research Institute, Beijing, China
| |
Collapse
|
19
|
Hemodynamic Evaluation of a Centrifugal Left Atrial Decompression Pump for Heart Failure with Preserved Ejection Fraction. Bioengineering (Basel) 2023; 10:bioengineering10030366. [PMID: 36978757 PMCID: PMC10044772 DOI: 10.3390/bioengineering10030366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/08/2023] [Accepted: 03/12/2023] [Indexed: 03/19/2023] Open
Abstract
This article discusses a new continuous flow mini pump that has been developed to improve symptoms and prognosis in patients with Heart Failure with Preserved Ejection Fraction (HFpEF), for which there are currently no established treatments. The pump is designed to discharge a reduced percentage of blood volume from the left atrium to the subclavian artery, clamped at the bifurcation with the aortic arch. The overall specifications, design parameters, and hemodynamics of this new device are discussed, along with data from in vitro circulation loop tests and numerical simulations. The article also compares the results for two configurations of the pump with respect to key indicators of hemocompatibility used in blood pump development.
Collapse
|
20
|
Li S, Jin D, Gui X. Dynamic characteristic modeling of left ventricular assist devices based on hysteresis effects. Comput Biol Med 2023; 157:106737. [PMID: 36921456 DOI: 10.1016/j.compbiomed.2023.106737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Revised: 01/24/2023] [Accepted: 03/01/2023] [Indexed: 03/08/2023]
Abstract
OBJECTIVE The purpose of this study is to develop a new model for the dynamic characteristics of left ventricular assist devices (LVADs) interacting with the cardiovascular system under constant-speed modes. METHODS A new hysteresis model is established on the basis of the hysteresis effect and turbomachinery principles. The simulation results from the hysteresis model were compared with the inertia model. The in-vitro experiment results of a centrifugal pump (from literature) and the unsteady computational fluid dynamics (CFD) simulation results of an axial pump were used as the benchmarks. RESULTS Compared with the inertia model, at the partial support mode, the relative estimation error of the time to the maximum and minimum pump flow (Q) in the hysteresis model decreased at least 16.3% cardiac cycle (Tc) in the centrifugal pump and at least 1.9% Tc in the axial pump, indicating its ability to simulate more realistic Q fluctuations. Moreover, the hysteresis model could predict an accurate time distribution of different Q. CONCLUSION The hysteresis model provides a general calculation method for simulating the dynamic characteristics of constant-speed LVADs under interaction with the cardiovascular system. It is more accurate than the inertia model. SIGNIFICANCE The hysteresis model is helpful for the rapid estimation of unsteady dynamic characteristics in absence of a physical pump prototype at the preliminary design stage.
Collapse
Affiliation(s)
- Shulei Li
- School of Energy and Power Engineering, Beihang University, Beijing, PR China
| | - Donghai Jin
- School of Energy and Power Engineering, Beihang University, Beijing, PR China.
| | - Xingmin Gui
- School of Energy and Power Engineering, Beihang University, Beijing, PR China
| |
Collapse
|
21
|
Li Y, Xi Y, Wang H, Sun A, Deng X, Chen Z, Fan Y. The impact of rotor configurations on hemodynamic features, hemocompatibility and dynamic balance of the centrifugal blood pump: A numerical study. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3671. [PMID: 36507614 DOI: 10.1002/cnm.3671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 09/11/2022] [Accepted: 12/04/2022] [Indexed: 06/17/2023]
Abstract
To investigate the effect of rotor design configuration on hemodynamic features, hemocompatibility and dynamic balance of blood pumps. Computational fluid dynamics was employed to investigate the effects of rotor type (closed impeller, semi-open impeller), clearance height and back vanes on blood pump performance. In particular, the Eulerian hemolysis model based on a power-law function and the Lagrangian thrombus model with integrated stress accumulation and residence time were applied to evaluate the hemocompatibility of the blood pump. This study shows that compared to the closed impeller, the semi-open impeller can improve hemolysis at a slight sacrifice in head pressure, but increase the risk of thrombogenic potential and disrupt rotor dynamic balance. For the semi-open impeller, the pressure head, hemolysis, and axial thrust of the blood pump decrease with increasing front clearance, and the risk of thrombosis increases first and then decreases with increasing front clearance. Variations in back clearance have little effect on pressure head, but larger on back clearance, worsens hemolysis, thrombogenic potential and rotor dynamic balance. The employment of back vanes has little effect on the pressure head. All back vanes configurations have an increased risk of hemolysis in the blood pump but are beneficial for the improvement of the rotor dynamic balance of the blood pump. Reasonable back vanes configuration (higher height, wider width, longer length and more number) decreases the flow separation, increases the velocity of blood in the back clearance, and reduces the risk of blood pooling and thrombosis. It was also found that hemolysis index (HI) was highly negatively correlated with pressure difference between the top and back clearances (r = -.87), and thrombogenic potential was positively correlated with pressure difference between the top and back clearances (r = .71). This study found that rotor type, clearance height, and back vanes significantly affect the hydraulic performance, hemocompatibility and rotor dynamic balance of centrifugal blood pumps through secondary flow. These parameters should be carefully selected when designing and optimizing centrifugal blood pumps for improving the blood pump clinical outcomes.
Collapse
Affiliation(s)
- Yuan Li
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yifeng Xi
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Hongyu Wang
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Anqiang Sun
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Xiaoyan Deng
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Zengsheng Chen
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| |
Collapse
|
22
|
Gil A, Navarro R, Quintero P, Mares A. Hemocompatibility and hemodynamic comparison of two centrifugal LVADs: HVAD and HeartMate3. Biomech Model Mechanobiol 2023; 22:871-883. [PMID: 36648697 PMCID: PMC10167126 DOI: 10.1007/s10237-022-01686-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Accepted: 12/28/2022] [Indexed: 01/18/2023]
Abstract
Mechanical circulatory support using ventricular assist devices is a common technique for treating patients suffering from advanced heart failure. The latest generation of devices is characterized by centrifugal turbopumps which employ magnetic levitation bearings to ensure a gap clearance between moving and static parts. Despite the increasing use of these devices as a destination therapy, several long-term complications still exist regarding their hemocompatibility. The blood damage associated with different pump designs has been investigated profoundly in the literature, while the hemodynamic performance has been hardly considered. This work presents a novel comparison between the two main devices of the latest generation-HVAD and HM3-from both perspectives, hemodynamic performance and blood damage. Computational fluid dynamics simulations are performed to model the considered LVADs, and computational results are compared to experimental measurements of pressure head to validate the model. Enhanced performance and hemocompatibility are detected for HM3 owing to its design incorporating more conventional blades and larger gap clearances.
Collapse
Affiliation(s)
- Antonio Gil
- CMT-Motores Térmicos, Universitat Politècnica de València, Camino de Vera, S/N, 46022, Valencia, Spain
| | - Roberto Navarro
- CMT-Motores Térmicos, Universitat Politècnica de València, Camino de Vera, S/N, 46022, Valencia, Spain
| | - Pedro Quintero
- CMT-Motores Térmicos, Universitat Politècnica de València, Camino de Vera, S/N, 46022, Valencia, Spain
| | - Andrea Mares
- CMT-Motores Térmicos, Universitat Politècnica de València, Camino de Vera, S/N, 46022, Valencia, Spain.
| |
Collapse
|
23
|
Bounouib M, Benakrach H, Taha-Janan M, Maazouzi W. Analysis of shear stress related hemolysis in a ventricular assist device. Biomed Mater Eng 2023; 34:51-66. [PMID: 35988210 DOI: 10.3233/bme-221401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
BACKGROUND Implantable devices such as ventricular assist devices provide appropriate treatment for patients with advanced heart failure. Unfortunately, these devices still have many problems, particularly related to blood damage. OBJECTIVE The aim of this research is to examine two new ventricular assist devices in terms of induced shear stress, exposure time, and induced hemolysis. METHOD Reverse engineering was used on multiple axial flow ventricular assist devices to collect all the details related to the designs (diameters, lengths, blade angles…), which were used to build two prototypes: Model A and Model B. RESULTS The obtained results were close to a large extent, except for static pressure rise, where the difference was clear. CONCLUSION Compared with what has been published in other studies, the overall performance of both models was excellent.
Collapse
Affiliation(s)
- Mohamed Bounouib
- Laboratory of Applied Mechanics and Technologies, ENSAM, Mohammed V University, Rabat, Morocco
| | - Hind Benakrach
- Laboratory of Applied Mechanics and Technologies, ENSAM, Mohammed V University, Rabat, Morocco
| | - Mourad Taha-Janan
- Laboratory of Applied Mechanics and Technologies, ENSAM, Mohammed V University, Rabat, Morocco
| | - Wajih Maazouzi
- Industrial and Health Science and Technology Research Center (STIS), ENSAM, Mohammed V University, Rabat, Morocco
| |
Collapse
|
24
|
Computational Modeling of the Penn State Fontan Circulation Assist Device. ASAIO J 2022; 68:1513-1522. [PMID: 35421006 DOI: 10.1097/mat.0000000000001708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
To address the increasing number of failing Fontan patients, Penn State University and the Penn State Hershey Medical Center are developing a centrifugal blood pump for long-term mechanical support. Computational fluid dynamics (CFD) modeling of the Penn State Fontan Circulatory Assist Device (FCAD) was performed to understand hemodynamics within the pump and its potential for hemolysis and thrombosis. CFD velocity and pressure results were first validated against experimental data and found to be within the standard deviations of the velocities and within 5% of the pressures. Further simulations performed with a human blood model found that most of the fluid domain was subjected to low shear stress (<50 Pa), with areas of highest stress around the rotor blade tips that increased with pump flow rate and rotor speed (138-178 Pa). However, the stresses compared well to previous CFD studies of commercial blood pumps and remained mostly below common thresholds of hemolysis and platelet activation. Additionally, few regions of low shear rate were observed within the FCAD, signifying minimal potential for platelet adhesion. These results further emphasize the FCAD's potential that has been observed previously in experimental and animal studies.
Collapse
|
25
|
Li Y, Wang H, Xi Y, Sun A, Deng X, Chen Z, Fan Y. Multi-indicator analysis of mechanical blood damage with five clinical ventricular assist devices. Comput Biol Med 2022; 151:106271. [PMID: 36347061 DOI: 10.1016/j.compbiomed.2022.106271] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 09/29/2022] [Accepted: 10/30/2022] [Indexed: 11/07/2022]
Abstract
PURPOSE Device-induced blood damage contributes the hemolysis, thrombosis and bleeding complications in patients supported with ventricular assist device (VAD). This study aims to use a multi-indicator method to understand how devices causes blood damage and identify the "hot spots" of blood trauma within VADs. METHODS Computational fluid dynamics (CFD) methods were chosen to investigate the hemodynamic features of five clinical VADs (Impella 5.0, UltraMag, CHVAD, HVAD, and HeartMate II) under the same clinical support condition (flow rate of 4.5L/min, pressure head around 75 mmHg). A comprehensive multi-indicator evaluation method including hemodynamic parameters, hemolysis model, thrombotic potential model and bleeding probability model was used to analyze blood damage and assess the hemodynamic performance and hemocompatibility of these VADs. RESULTS Simulation results show that shear stress from 50 Pa to 100 Pa plays a major role in blood damage in Impella 5.0, UltraMag and CHVAD, while blood damage in HVAD and HeartMate II is mainly caused by shear stress greater than 100 Pa. Residence time was not the main factor for blood damage in Impella 5.0, and also makes a limited contribution to blood trauma in UltraMag and CHVAD, while it takes a critical role in elevating thrombotic potential in HVAD and HeartMate II. The distribution of regions of high hemolysis risk and high bleeding probability was similar for all these VADs and partially overlapped for high thrombotic potential regions. For Impella 5.0, regions with high hemolysis and bleeding risk were found mainly in the blade tip clearance and diffuser domains, high thrombotic potential regions were almost absent. For UltraMag, regions with high hemolysis, bleeding and thrombosis potential were found in two corners of the inlet pipe, the secondary flow passage, and the impeller eye. For CHVAD, the high-risk regions for hemolysis, bleeding and thrombosis are mainly in the inner side of the secondary flow passage and the middle region of the impeller passage. The narrow hydrodynamic clearance and impeller passage had a high risk of hemolysis and bleeding, and the clearance between the rotor and guide cone and the hydrodynamic clearance had high thrombotic potential. For HeartMate II, regions of high hemolysis risk and bleeding probability were found in the near-wall region of the straightener, the blade tip clearance and the diffuser domain. The corners of the inlet and outlet pipe and the straightener and diffuser regions had high thrombotic potential. CONCLUSION The risk of hemolysis, bleeding and thrombosis for these five VADs, in increasing order, was Impella 5.0, UltraMag, CHVAD, HVAD, and HeartMate II. Flow losses caused by the rotor mechanical movement, chaotic flow and narrow clearances increase the blood damage for all these VADs. The multi-indicator analysis can comprehensively evaluate the VAD performance with improved assessment accuracy of CFD.
Collapse
Affiliation(s)
- Yuan Li
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Hongyu Wang
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Yifeng Xi
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Anqiang Sun
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Xiaoyan Deng
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Zengsheng Chen
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China.
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China.
| |
Collapse
|
26
|
Torner B, Frank D, Grundmann S, Wurm FH. Flow simulation-based particle swarm optimization for developing improved hemolysis models. Biomech Model Mechanobiol 2022; 22:401-416. [PMID: 36441414 PMCID: PMC10097800 DOI: 10.1007/s10237-022-01653-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 10/23/2022] [Indexed: 11/29/2022]
Abstract
AbstractThe improvement and development of blood-contacting devices, such as mechanical circulatory support systems, is a life saving endeavor. These devices must be designed in such a way that they ensure the highest hemocompatibility. Therefore, in-silico trials (flow simulations) offer a quick and cost-effective way to analyze and optimize the hemocompatibility and performance of medical devices. In that regard, the prediction of blood trauma, such as hemolysis, is the key element to ensure the hemocompatibility of a device. But, despite decades of research related to numerical hemolysis models, their accuracy and reliability leaves much to be desired. This study proposes a novel optimization path, which is capable of improving existing models and aid in the development of future hemolysis models. First, flow simulations of three, turbulent blood flow test cases (capillary tube, FDA nozzle, FDA pump) were performed and hemolysis was numerically predicted by the widely-applied stress-based hemolysis models. Afterward, a multiple-objective particles swarm optimization (MOPSO) was performed to tie the physiological stresses of the simulated flow field to the measured hemolysis using an equivalent of over one million numerically determined hemolysis predictions. The results show that our optimization is capable of improving upon existing hemolysis models. However, it also unveils some deficiencies and limits of hemolysis prediction with stress-based models, which will need to be addressed in order to improve its reliability.
Collapse
|
27
|
Klein M, Tack JC, Mager I, Maas J, Schmitz-Rode T, Arens J, Steinseifer U, Clauser JC. In vitro thrombogenicity evaluation of rotary blood pumps by thromboelastometry. BIOMED ENG-BIOMED TE 2022; 67:471-480. [PMID: 36041741 DOI: 10.1515/bmt-2022-0078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 08/02/2022] [Indexed: 11/15/2022]
Abstract
In vitro thrombogenicity tests for rotary blood pumps (RBPs) could benefit from assessing coagulation kinematics, as RBP design improves. In this feasibility study, we investigated if the method of thromboelastometry (TEM) is able to assess coagulation kinematics under the in vitro conditions of RBP tests. We conducted in vitro thrombogenicity tests (n=4) by placing Deltastream® DP3 pumps into test loops that were filled with 150 mL of slightly anti-coagulated porcine blood, adjusted to an activated clotting time (ACT) well below clinically recommended levels. Blood samples were taken at certain time points during the experiment until a continuous decrease in pump flow indicated major thrombus formation. Blood samples were analyzed for ACT, platelet count (PLT), and several TEM parameters. While visible thrombus formation was observed in three pumps, ACT indicated an ongoing activation of coagulation, PLT might have indicated platelet consumption. Unexpectedly, most TEM results gave no clear indications. Nonetheless, TEM clotting time obtained by non-anticoagulated and chemically non-activated whole blood (HEPNATEM-CT) appeared to be more sensitive for the activation of coagulation in vitro than ACT, which might be of interest for future pump tests. However, more research regarding standardization of thrombogenicity pump tests is urgently required.
Collapse
Affiliation(s)
- Mario Klein
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Jana Christine Tack
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Ilona Mager
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Judith Maas
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Thomas Schmitz-Rode
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany.,Chair in Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Johanna Charlotte Clauser
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
28
|
Li C, Qiu H, Ma J, Wang Y. Numerical study on the performance of centrifugal blood pump with superhydrophobic surface. Int J Artif Organs 2022; 45:1028-1036. [PMID: 36028949 DOI: 10.1177/03913988221114156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
AIM In order to reduce the blood damage of an artificial heart pump and optimize its hydraulic performance, a centrifugal blood pump with superhydrophobic characteristics is proposed in this study. METHODS To study the influence of superhydrophobic surface characteristics on the performance of centrifugal blood pumps, the Navier slip model is used to simulate the slip characteristics of superhydrophobic surfaces, which is realized by the user defined function of ANSYS fluent. The user defined functions with different values of slip length are verified by two benchmark solutions of laminar flow and turbulence in the pipeline. The blood pump model adopts the designed centrifugal blood pump, and its head, hydraulic efficiency and hemolysis index are calculated. The Navier slip boundary condition (a constant slip-length of 50 μm) is applied to the walls of the blood pump impeller and a volute at different positions, and the influence of the superhydrophobic surface on the performance of the blood pump at the design point Q = 6 L/min was compared and analyzed. RESULTS The results show that the centrifugal blood pump model used in this paper has good blood compatibility and meets the design requirements; the superhydrophobic surface can significantly reduce the scalar shear stress in the blood pump. At the design point, when the slip length is 50 μm, the mass-average scalar shear stress in the impeller area and the volute area reduction rate is about 5.9%, the hydraulic efficiency growth rate is about 3.8%, the hemolysis index reduction rate is about 18.4%, and the pressure head changes little with a growth rate of 0.3%. CONCLUSIONS Centrifugal blood pumps with superhydrophobic surfaces can improve the efficiency of blood pumps and reduce hemolysis. Based on these encouraging results, vitro investigations for actual blood damage would be practicable.
Collapse
Affiliation(s)
- Chengcheng Li
- Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Huihe Qiu
- Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong
| | - Jianying Ma
- Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai, China
| | - Ying Wang
- Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, China.,Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong
| |
Collapse
|
29
|
Goodman D, Stulak J, Rosenbaum AN. Left ventricular assist devices: A historical perspective at the intersection of medicine and engineering. Artif Organs 2022; 46:2343-2360. [PMID: 35929377 DOI: 10.1111/aor.14371] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 07/06/2022] [Accepted: 07/18/2022] [Indexed: 11/26/2022]
Abstract
Over the last half-century, left ventricular assist device (LVAD) technology has progressed from conceptual therapy for failed cardiopulmonary bypass weaning to an accepted destination therapy for advanced heart failure. The history of LVAD engineering is defined by an initial development phase, which demonstrated the feasibility of such an approach, to the more recent three major generations of commercial devices. In this review, we explore the engineering challenges of LVADs, how they were addressed over time, and the clinical outcomes that resulted from each major technological development. The first generation of commercial LVADs were pulsatile devices, which lacked the appropriate durability due to their number of moving components and hemocompatibility. The second generation of LVADs was defined by replacement of complex, pulsatile pumps with primarily axial, continuous-flow systems with an impeller in the blood passageway. These devices experienced significant commercial success, but the presence of excessive trauma to the blood and in-situ bearing resulted in an unacceptable burden of adverse events. Third generation centrifugal-flow pumps use magnetically suspended rotors within the pump chamber. Superior outcomes with this newest generation of devices have been observed, particularly with respect to hemocompatibility-related adverse events including pump thrombosis, with fully magnetically levitated devices. The future of LVAD engineering includes wireless charging foregoing percutaneous drivelines and more advanced pump control mechanisms, including synchronization of the pump flow with the native cardiac cycle, and varying pump output based on degree of physical exertion using sensor or advanced device-level data triggers.
Collapse
Affiliation(s)
- Daniel Goodman
- College of Osteopathic Medicine, Des Moines University, Des Moines, Iowa, USA
| | - John Stulak
- Division of Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - Andrew N Rosenbaum
- Department of Cardiovascular Diseases, Mayo Clinic Minnesota, Rochester, Minnesota, USA
| |
Collapse
|
30
|
Escher A, Hubmann EJ, Karner B, Messner B, Laufer G, Kertzscher U, Zimpfer D, Granegger M. Linking Hydraulic Properties to Hemolytic Performance of Rotodynamic Blood Pumps. ADVANCED THEORY AND SIMULATIONS 2022. [DOI: 10.1002/adts.202200117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Andreas Escher
- Department of Cardiac Surgery Medical University of Vienna Vienna 1090 Austria
| | | | - Barbara Karner
- Department of Cardiac Surgery Medical University of Vienna Vienna 1090 Austria
| | - Barbara Messner
- Cardiac Surgery Research Laboratory Medical University of Vienna Vienna 1090 Austria
| | - Günther Laufer
- Department of Cardiac Surgery Medical University of Vienna Vienna 1090 Austria
| | - Ulrich Kertzscher
- Biofluid Mechanics Laboratory Charité‐Universitätsmedizin Berlin 10117 Berlin Germany
| | - Daniel Zimpfer
- Department of Cardiac Surgery Medical University of Vienna Vienna 1090 Austria
| | - Marcus Granegger
- Department of Cardiac Surgery Medical University of Vienna Vienna 1090 Austria
- Biofluid Mechanics Laboratory Charité‐Universitätsmedizin Berlin 10117 Berlin Germany
| |
Collapse
|
31
|
Govender K, Jani VP, Cabrales P. The Disconnect Between Extracorporeal Circulation and the Microcirculation: A Review. ASAIO J 2022; 68:881-889. [PMID: 35067580 DOI: 10.1097/mat.0000000000001618] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Extracorporeal circulation (ECC) procedures, such as cardiopulmonary bypass (CPB) and extracorporeal membrane oxygenation (ECMO), take over the function of one or more organs, providing clinicians time to treat underlying pathophysiological conditions. ECMO and CPB carry significant mortality rates for patients, despite prior decades of research focused on the resulting failure of critical organs. Since the focus of these procedures is to support blood flow and provide oxygen-rich blood to tissues, a shift in research toward the effects of ECMO and CPB on the microcirculation is warranted. Along with provoking systemic responses, both procedures disrupt the integrity of red blood cells, causing release of hemoglobin (Hb) from excessive foreign surface contact and mechanical stresses. The effects of hemolysis are especially pronounced in the microcirculation, where plasma Hb leads to nitric oxide scavenging, oxidization, formation of reactive oxygen species, and inflammatory responses. A limited number of studies have investigated the implications of ECMO in the microcirculation, but more work is needed to minimize ECMO-induced reduction of microcirculatory perfusion and consequently oxygenation. The following review presents existing information on the implications of ECMO and CPB on microvascular function and proposes future studies to understand and leverage key mechanisms to improve patient outcomes.
Collapse
Affiliation(s)
- Krianthan Govender
- From the Functional Cardiovascular Engineering Laboratory, University of California, San Diego, La Jolla, California
| | | | | |
Collapse
|
32
|
Zhang Y, Wu X, Wang Y, Liu H, Liu GM. The hemodynamics and blood trauma in axial blood pump under different operating model. Artif Organs 2022; 46:2159-2170. [PMID: 35735995 DOI: 10.1111/aor.14348] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 05/11/2022] [Accepted: 06/06/2022] [Indexed: 11/29/2022]
Abstract
Speed modulation of blood pump has been proved to help restore vascular pulsatility and implemented clinically during treatment for cardiac failure. However, its effect on blood trauma has not been studied thoroughly. In this paper, we study the flow field of an axial pump FW-X under the modes of co-pulse, counter pulse and constant speed to evaluate the blood trauma. Based on the coupling model of cardiovascular system and axial blood pump, aortic pressure and the pump flow were obtained and applied as the boundary conditions at the pump outlet and inlet. The level of shear stress and hemolysis index were derived from computational fluid dynamics (CFD) simulation. Results showed the constant speed mode had the lowest shear stress level and hemolytic index at the expense of diminished pulsatility. Compared with the constant speed mode, the hemolysis index of co-pulse and counter pulse mode was higher, but it was helpful to restore vascular pulsatility. This method can be easily incorporated in the in vitro testing phase to analyze and decrease a pump's trauma before animal experimentation, thereby reducing the cost of blood pump development.
Collapse
Affiliation(s)
- Yunpeng Zhang
- School of Electrical Engineering, Shandong University, Jinan, China
| | - Xiangyu Wu
- School of Electrical Engineering, Shandong University, Jinan, China
| | - Yiming Wang
- School of Electrical Engineering, Shandong University, Jinan, China
| | - Hongtao Liu
- School of Goertek Technology and Industry, Weifang University, Weifang, China
| | - Guang-Mao Liu
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
33
|
Gil A, Navarro R, Quintero P, Mares A, Pérez M, Montero JA. CFD analysis of the HVAD's hemodynamic performance and blood damage with insight into gap clearance. Biomech Model Mechanobiol 2022; 21:1201-1215. [PMID: 35546646 DOI: 10.1007/s10237-022-01585-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 04/11/2022] [Indexed: 11/26/2022]
Abstract
Mechanical circulatory support using ventricular assist devices has become commonplace in the treatment of patients suffering from advanced stages of heart failure. While blood damage generated by these devices has been evaluated in depth, their hemodynamic performance has been investigated much less. This work presents the analysis of the complete operating map of a left ventricular assist device, in terms of pressure head, power and efficiency. Further investigation into its hemocompatibility is included as well. To achieve these objectives, computational fluid dynamics simulations of a centrifugal blood pump with a wide-blade impeller were performed. Several conditions were considered by varying the rotational speed and volumetric flow rate. Regarding the device's hemocompatibility, blood damage was evaluated by means of the hemolysis index. By relating the hemocompatibility of the device to its hemodynamic performance, the results have demonstrated that the highest hemolysis occurs at low flow rates, corresponding to operating conditions of low efficiency. Both performance and hemocompatibility are affected by the gap clearance. An innovative investigation into the influence of this design parameter has yielded decreased efficiencies and increased hemolysis as the gap clearance is reduced. As a further novelty, pump operating maps were non-dimensionalized to highlight the influence of Reynolds number, which allows their application to any working condition. The pump's operating range places it in the transitional regime between laminar and turbulent, leading to enhanced efficiency for the highest Reynolds number.
Collapse
Affiliation(s)
- Antonio Gil
- CMT-Motores Térmicos, Universitat Politècnica de València, Camí de Vera, s/n, 46022, Valencia, Spain
| | - Roberto Navarro
- CMT-Motores Térmicos, Universitat Politècnica de València, Camí de Vera, s/n, 46022, Valencia, Spain
| | - Pedro Quintero
- CMT-Motores Térmicos, Universitat Politècnica de València, Camí de Vera, s/n, 46022, Valencia, Spain
| | - Andrea Mares
- CMT-Motores Térmicos, Universitat Politècnica de València, Camí de Vera, s/n, 46022, Valencia, Spain.
| | - Manuel Pérez
- Servicio de Cirugía Cardíaca, Hospital Universitario La Fe, Avinguda de Fernando Abril Martorell, 106, 46026, Valencia, Spain
| | - Jose Anastasio Montero
- Servicio de Cirugía Cardíaca, Hospital Universitario La Fe, Avinguda de Fernando Abril Martorell, 106, 46026, Valencia, Spain
| |
Collapse
|
34
|
Wu P, Huo JD, Zhang ZJ, Wang CJ. The influence of non-conformal grid interfaces on the results of large eddy simulation of centrifugal blood pumps. Artif Organs 2022; 46:1804-1816. [PMID: 35436356 DOI: 10.1111/aor.14263] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 02/26/2022] [Accepted: 04/08/2022] [Indexed: 11/27/2022]
Abstract
BACKGROUND Computational fluid dynamics has been widely used to assist the design and evaluation of blood pumps. Discretization errors associated with computational grid may influence the credibility of numerical simulations. Non-conformal grid interfaces commonly exist in rotary machines, including rotary blood pumps. Should grid size across the interface differ greatly, large errors may occur. METHODS This study explored the effects of non-conformal grid interface on the prediction of the flow field and hemolysis in blood pumps using large eddy simulation (LES). Two benchmarks, a nozzle model and a centrifugal blood pump were chosen as test cases. RESULTS This study found that non-conformal grid interfaces with considerable change of grid sizes led to discontinuities of flow variables and brought errors to metrics such as pressure head (7%) and hemolysis (up to 14%). CONCLUSIONS The results on the full unstructured grid are more accurate with negligible changes of flow variables across the non-conformal grid interface. A full unstructured grid should be employed for centrifugal blood pumps to minimize the influence of non-conformal grid interfaces for LES simulations.
Collapse
Affiliation(s)
- Peng Wu
- Artificial Organ Technology Laboratory, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Jia-Dong Huo
- Artificial Organ Technology Laboratory, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Zi-Jian Zhang
- Artificial Organ Technology Laboratory, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| | - Chun-Ju Wang
- Robotics and Microsystems Center, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China
| |
Collapse
|
35
|
Li Y, Yu J, Wang H, Xi Y, Deng X, Chen Z, Fan Y. Investigation of the influence of blade configuration on the hemodynamic performance and blood damage of the centrifugal blood pump. Artif Organs 2022; 46:1817-1832. [PMID: 35436361 DOI: 10.1111/aor.14265] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2021] [Revised: 03/01/2022] [Accepted: 04/08/2022] [Indexed: 11/30/2022]
Abstract
PURPOSE The design and optimization of centrifugal blood pumps is crucial for improved extracorporeal membrane oxygenation system performances. Secondary flow passages are common in centrifugal blood pumps, allowing for a high volume of unstable flow. Traditional design theory offers minimal guidance on the design and optimization of centrifugal blood pumps, so it's critical to understand how design parameter variables affect hydraulic performances and hemocompatibility. METHODS Computational fluid dynamics (CFD) was employed to investigate the effects of blade number, blade wrap angle, blade thickness, and splitters on pressure head, hemolysis, and platelet activation state. Eulerian and Lagrangian features were used to analyze the flow fields and hemocompatibility metrics such as scalar shear stress, velocity distribution, and their correlation. RESULTS The equalization of frictional and flow losses allow impellers with more blades and smaller wrap angles to have higher pressure heads, whereas the trade-off between the volume of high scalar shear stress and exposure time allows impellers with fewer blades and larger blade wrap angles to have a lower HI; there are configurations that increase the possibility of platelet activation for both number of blades and wrap angles. The hydraulic performance and hemocompatibility of centrifugal blood pumps are not affected by blade thickness. Compared to the main blades, a splitters can improve the blood compatibility of a centrifugal blood pump with a small reduction in pressure head, but there is a trade-off between the length and location of the splitter that suppresses flow losses while reducing the velocity gradient. According to correlation analysis, pressure head, HI, and the volume of high shear stress were all substantially connected, and exposure time had a significant impact on HI. The platelet activation state was influenced by the average scalar shear stress and the volume of low velocity. CONCLUSION The findings reveal the impact of design variables on the performance of centrifugal blood pumps with secondary flow passages, as well as the relationship between hemocompatibility, hydraulic performance, and flow characteristics, and are useful for the design and optimization of this type of blood pump, as well as the prediction of clinical complications.
Collapse
Affiliation(s)
- Yuan Li
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Jiachen Yu
- School of Sino-french Engineer, Beihang University, Beijing, 100083, China
| | - Hongyu Wang
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Yifeng Xi
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Xiaoyan Deng
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Zengsheng Chen
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| |
Collapse
|
36
|
Han D, Zhang J, Griffith BP, Wu ZJ. Models of Shear-Induced Platelet Activation and Numerical Implementation With Computational Fluid Dynamics Approaches. J Biomech Eng 2022; 144:1119644. [PMID: 34529037 DOI: 10.1115/1.4052460] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Indexed: 12/17/2022]
Abstract
Shear-induced platelet activation is one of the critical outcomes when blood is exposed to elevated shear stress. Excessively activated platelets in the circulation can lead to thrombus formation and platelet consumption, resulting in serious adverse events such as thromboembolism and bleeding. While experimental observations reveal that it is related to the shear stress level and exposure time, the underlying mechanism of shear-induced platelet activation is not fully understood. Various models have been proposed to relate shear stress levels to platelet activation, yet most are modified from the empirically calibrated power-law model. Newly developed multiscale platelet models are tested as a promising approach to capture a single platelet's dynamic shape during activation, but it would be computationally expensive to employ it for a large-scale analysis. This paper summarizes the current numerical models used to study the shear-induced platelet activation and their computational applications in the risk assessment of a particular flow pattern and clot formation prediction.
Collapse
Affiliation(s)
- Dong Han
- Department of Surgery, University of Maryland School of Medicine, 10 South Pine Street, MSTF 436, Baltimore, MD 21201
| | - Jiafeng Zhang
- Department of Surgery, University of Maryland School of Medicine, 10 South Pine Street, MSTF 436, Baltimore, MD 21201
| | - Bartley P Griffith
- Department of Surgery, University of Maryland School of Medicine, 10 South Pine Street, MSTF 436, Baltimore, MD 21201
| | - Zhongjun J Wu
- Department of Surgery, University of Maryland School of Medicine, 10 South Pine Street, MSTF 436, Baltimore, MD 21201; Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, MD 20742
| |
Collapse
|
37
|
Qu Y, Guo Z, Zhang J, Li G, Zhang S, Li D. Hemodynamic investigation and in vitro evaluation of a novel mixed flow blood pump. Artif Organs 2022; 46:1533-1543. [PMID: 35167128 DOI: 10.1111/aor.14210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2021] [Revised: 01/20/2022] [Accepted: 02/07/2022] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Ventricular assist devices (VADs) are considered as an effective treatment for patients with advanced heart failure, while complications associated with blood damage remain a burden. Structure design innovation has potential to reduce hemolysis and improve hemocompatibility. METHODS In this research, a novel mixed flow blood pump that integrates structural features of the axial and centrifugal VADs was proposed. The pump consists of an inducer, a mixed impeller supported by two ceramic pivot bearings and a volute. The flow field and laminar viscous shear stress were analyzed by the in-silico simulation. The hydraulic and hemolytic performance were evaluated in vitro by using a 3D printed pump. RESULTS The flow field distribution showed that streamlines in the connection area were smoothly transitioned through structural integration and no irregular flow occurred in the entire flow channel. The axial blades work as a fluid accelerator (generating 18.56% of the energy), and the centrifugal blades provide the main pressure head. The proportion of fluid inside the pump exposed to low laminar viscous shear stress (<50 Pa) and high laminar viscous shear stress (>150 Pa) was 99.02% and 0.03%, respectively. The in vitro hemolysis test results showed that the NIH (Normalized Index of Hemolysis) value of the mixed pump is 0.0079 ± 0.0039 g/100 L (n=6). CONCLUSION It can be concluded that the mixed flow structure is effective to improve hydraulic performance, eliminate flow disturbance and minimize shear stresses. This novel pump design is expected to provide a new direction for the development of next-generation VADs.
Collapse
Affiliation(s)
- Yifei Qu
- Key Laboratory of High Efficiency and Clean Mechanical Manufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan, P.R. China.,Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan, P.R. China
| | - Ziyu Guo
- Key Laboratory of High Efficiency and Clean Mechanical Manufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan, P.R. China.,Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan, P.R. China
| | - Jing Zhang
- Key Laboratory of High Efficiency and Clean Mechanical Manufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan, P.R. China.,Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan, P.R. China
| | - Guiling Li
- School of Medicine, Tsinghua University, Beijing, P.R. China
| | - Song Zhang
- Key Laboratory of High Efficiency and Clean Mechanical Manufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan, P.R. China.,Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan, P.R. China
| | - Donghai Li
- Advanced Medical Research Institute, Shandong University, Jinan, P.R. China
| |
Collapse
|
38
|
Escher A, Gobel H, Nicolai M, Schloglhofer T, Hubmann EJ, Laufer G, Messner B, Kertzscher U, Zimpfer D, Granegger M. Hemolytic Footprint of Rotodynamic Blood Pumps. IEEE Trans Biomed Eng 2022; 69:2423-2432. [PMID: 35085069 DOI: 10.1109/tbme.2022.3146135] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE In preclinical examinations, rotodynamic blood pumps (RBPs) are predominantly evaluated at design-point conditions. In clinical practice, however, they run at diversified modes of operation. This study aimed at extending current preclinical evaluation of hemolytic profiles in RBPs toward broader, clinically relevant ranges of operation. METHODS Two implantable RBPs the HeartMate 3 (HM3) and the HeartWare Ventricular Assist Device (HVAD) were analyzed at three pump speeds (HM3: 4300, 5600, 7000rpm; HVAD: 1800, 2760, 3600rpm) with three flow rates (1-9L/min) per speed setting. Hemolysis measurements were performed in heparinized bovine blood. The delta free hemoglobin (dfHb) and the normalized index of hemolysis (NIH) served as hemolytic measures. Statistical analysis was performed by multiple comparison of the 9 operating conditions. Moreover, computational fluid dynamics (CFD) was applied to provide mechanistic insights into the interrelation between hydraulics and hemolysis by correlating numerically computed hydraulic losses with in-vitro hemolytic measures. RESULTS In both devices, dfHb increased toward increasing speeds, particularly during low but also during high flow condition. By contrast, in both RBPs magnitudes of NIH were significantly elevated during low flow operation compared to high flow conditions (p<0.0036). Maps of hemolytic metrics revealed morphologically similar trends to in-silico hydraulic losses (r>0.793). CONCLUSIONS While off-design operation is associated with increased hemolytic profiles, the setting of different operating conditions render a preclinical prediction of clinical impact with current hemolysis metrics difficult. SIGNIFICANCE The identified increase in hemolytic measures during episodes of off-design operation is highlighting the need to consider worst-case operation during preclinical examinations.
Collapse
|
39
|
Hemolytic Performance in Two Generations of the Sputnik Left Ventricular Assist Device: A Combined Numerical and Experimental Study. J Funct Biomater 2022; 13:jfb13010007. [PMID: 35076513 PMCID: PMC8788462 DOI: 10.3390/jfb13010007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 12/22/2021] [Accepted: 01/07/2022] [Indexed: 02/05/2023] Open
Abstract
Background: Currently, left ventricular assist devices (LVADs) are a successful surgical treatment for patients with end-stage heart failure on the waiting list or with contraindicated heart transplantation. In Russia, Sputnik 1 LVAD was also successfully introduced into clinical practice as a bridge-to-transplant and a destination therapy device. Development of Sputnik 2 LVAD was aimed at miniaturization to reduce invasiveness, optimize hemocompatibility, and improve versatility for patients of various sizes. Methods: We compared hemolysis level in flow path of the Sputnik LVADs and investigated design aspects influencing other types of blood damage, using predictions of computational fluid dynamics (CFD) and experimental assessment. The investigated operating point was a flow rate of 5 L/min and a pressure head of 100 mm Hg at an impeller rotational speed of 9100 min−1. Results: Mean hemolysis indices predicted with CFD were 0.0090% in the Sputnik 1 and 0.0023% in the Sputnik 2. Averaged values of normalized index of hemolysis obtained experimentally for the Sputnik 1 and the Sputnik 2 were 0.011 ± 0.003 g/100 L and 0.004 ± 0.002 g/100 L, respectively. Conclusions: Obtained results indicate obvious improvements in hemocompatibility and sufficiently satisfy the determined miniaturization aim for the Sputnik 2 LVAD development.
Collapse
|
40
|
Development of Inspired Therapeutics Pediatric VAD: Computational Analysis and Characterization of VAD V3. Cardiovasc Eng Technol 2022; 13:624-637. [PMID: 35013917 DOI: 10.1007/s13239-021-00602-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Accepted: 12/09/2021] [Indexed: 11/02/2022]
Abstract
PURPOSE Pediatric heart failure patients remain in critical need of a dedicated mechanical circulatory support (MCS) solution as development efforts for specific pediatric devices continue to fall behind those for the adult population. The Inspired Pediatric VAD is being developed as a pediatric specific MCS solution to provide up to 30-days of circulatory or respiratory support in a compact modular package that could allow for patient ambulation during treatment. METHODS Hydrodynamic performance (flows, pressures), impeller/rotor mechanical properties (torques, forces), and flow shear stress and residence time distributions of the latest design version, Inspired Pediatric VAD V3, were numerically predicted and investigated using computational fluid dynamics (CFD) software (SolidWorks Flow Simulator). RESULTS Hydrodynamic performance was numerically predicted, indicating no change in flow and pressure head compared to the previous device design (V2), while displaying increased impeller/rotor torques and translation forces enabled by improved geometry. Shear stress and flow residence time volumetric distributions are presented over a range of pump rotational speeds and flow rates. At the lowest pump operating point (3000 RPM, 0.50 L/min, 75 mmHg), 79% of the pump volume was in the shear stress range of 0-10 Pa with < 1% of the volume in the critical range of 150-1000 Pa for blood damage. At higher speed and flow (5000 RPM, 3.50 L/min, 176 mmHg), 65% of the volume resided in the 0-10 Pa range compared to 2.3% at 150-1000 Pa. CONCLUSIONS The initial computational characterization of the Inspired Pediatric VAD V3 is encouraging and future work will include device prototype testing in a mock circulatory loop and acute large animal model.
Collapse
|
41
|
Mencarini T, Bozzi S, Redaelli A. On-Chip Platelet Activation Assessment: Microfluidic Emulation of Shear Stress Profiles Induced by Mechanical Circulatory Support Devices. Methods Mol Biol 2022; 2373:201-212. [PMID: 34520014 DOI: 10.1007/978-1-0716-1693-2_12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Mechanical circulatory support devices (MCSDs), although proved to be a pillar in the clinical setting of advanced heart failure, are afflicted by thromboembolic complications. Shear-mediated platelet activation has been recognized to drive thromboembolic events in patients implanted with MCSDs. Despite this, to date, a clinically reliable diagnostic test for assessing platelet response to stress stimuli is still missing. Here, we describe and apply the previously developed device thrombogenicity emulation methodology to the design of a microfluidic platform able to replicate shear stress profiles representative of MCSDs. The device-specific shear-mediated platelet activation is finally assessed by the platelet activity state assay, which measures real-time thrombin production, as a marker of platelet activation level. This technique can be employed to emulate the shear stress patterns of different MCSDs, such as mechanical heart valves, ventricular assist devices, and stents.
Collapse
Affiliation(s)
- Tatiana Mencarini
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Silvia Bozzi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Alberto Redaelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.
| |
Collapse
|
42
|
Sun W, Zhang J, Shah A, Arias K, Berk Z, Griffith BP, Wu ZJ. Neutrophil dysfunction due to continuous mechanical shear exposure in mechanically assisted circulation in vitro. Artif Organs 2022; 46:83-94. [PMID: 34516005 PMCID: PMC8688241 DOI: 10.1111/aor.14068] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 08/10/2021] [Accepted: 09/04/2021] [Indexed: 01/03/2023]
Abstract
OBJECTIVE Leukocytes play an important role in the body's immune system. The aim of this study was to assess alterations in neutrophil phenotype and function in pump-assisted circulation in vitro. METHODS Human blood was circulated for four hours in three circulatory flow loops with a CentriMag blood pump operated at a flow of 4.5 L/min at three rotational speeds (2100, 2800, and 4000 rpm), against three pressure heads (75, 150, and 350 mm Hg), respectively. Blood samples were collected hourly for analyses of neutrophil activation state (Mac-1, CD62L, CD162), neutrophil reactive oxygen species (ROS) production, apoptosis, and neutrophil phagocytosis. RESULTS Activated neutrophils indicated by both Mac-1 expression and decreased surface expression of CD62L and CD162 receptors increased with time in three loops. The highest level of neutrophil activation was observed in the loop with the highest rotational speed. Platelet-neutrophil aggregates (PNAs) progressively increased in two loops with lower rotational speeds. PNAs peaked at one hour after circulation and decreased subsequently in the loop with the highest rotational speed. Neutrophil ROS production dramatically increased at one hour after circulation and decreased subsequently in all three loops with similar levels and trends. Apoptotic neutrophils increased with time in all three loops. Neutrophil phagocytosis capacity in three loops initially elevated at one hour after circulation and decreased subsequently. Apoptosis and altered phagocytosis were dependent on rotational speed. CONCLUSIONS Our study revealed that the pump-assisted circulation induced neutrophil activation, apoptosis, and functional impairment. The alterations were strongly associated with pump operating condition and duration.
Collapse
Affiliation(s)
- Wenji Sun
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Jiafeng Zhang
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Aakash Shah
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Katherin Arias
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA,Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, Maryland, USA
| | - Zachary Berk
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Bartley P Griffith
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Zhongjun J Wu
- Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA,Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, Maryland, USA
| |
Collapse
|
43
|
Individual Variability in von Willebrand Factor Fragility in Response to Shear Stress: A Possible Clue for Predicting Bleeding Risk. ASAIO J 2021; 68:1128-1134. [PMID: 34967782 DOI: 10.1097/mat.0000000000001623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Acquired von Willebrand syndrome (AVWS), characterized by reduced von Willebrand factor (VWF) large multimers, has recently been implicated as the principal mechanism underlying bleeding in patients implanted with left ventricular assist devices (LVADs). Hematological severity of AVWS varies among patients, even if an identical device is implanted. We investigated whether this diversity in hematological severity is due to individual variability in VWF fragility, according to responses to incremental shear stress. Whole-blood samples were sheared at 20,000-40,000 s-1 shear rate, an index of shear stress, using a custom-made shear stressor that could generate shear stress compatible with that produced by an LVAD. The degree of VWF large multimers degradation was evaluated using the VWF large multimer index. A significant inverse correlation was observed between the VWF large multimer index and LVAD-compatible magnitudes of shear stress: the VWF large multimer indices were 68.5 ± 18.3, 48.0 ± 13.9, 33.9 ± 12.1, 23.7 ± 7.9, and 18.7% ± 8.7% at 20,000, 25,000, 30,000, 35,000, and 40,000 s-1 of shear rates, respectively (P < 0.0001). Furthermore, experimental VWF large multimer index values were compatible with those derived from patients with implanted LVADs (median; 28.9%). Finally, reduction in the VWF large multimer index corresponding to shear stress showed individual variation. We demonstrated that the combined use of a novel high shear stress loading device and quantitative evaluation of VWF large multimers may predict risk of bleeding before LVAD implantation.
Collapse
|
44
|
Chan CHH, Simmonds MJ, Fraser KH, Igarashi K, Ki KK, Murashige T, Joseph MT, Fraser JF, Tansley GD, Watanabe N. Discrete responses of erythrocytes, platelets, and von Willebrand factor to shear. J Biomech 2021; 130:110898. [PMID: 34896790 DOI: 10.1016/j.jbiomech.2021.110898] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 10/18/2021] [Accepted: 12/01/2021] [Indexed: 01/14/2023]
Abstract
Despite decades of technological advancements in blood-contacting medical devices, complications related to shear flow-induced blood trauma are still frequently observed in clinic. Blood trauma includes haemolysis, platelet activation, and degradation of High Molecular Weight von Willebrand Factor (HMW vWF) multimers, all of which are dependent on the exposure time and magnitude of shear stress. Specifically, accumulating evidence supports that when blood is exposed to shear stresses above a certain threshold, blood trauma ensues; however, it remains unclear how various constituents of blood are affected by discrete shears experimentally. The aim of this study was to expose blood to discrete shear stresses and evaluate blood trauma indices that reflect red cell, platelet, and vWF structure. Citrated human whole blood (n = 6) was collected and its haematocrit was adjusted to 30 ± 2% by adding either phosphate buffered saline (PBS) or polyvinylpyrrolidone (PVP). Viscosity of whole blood was adjusted to 3.0, 12.5, 22.5 and 37.5 mPa·s to yield stresses of 3, 6, 9, 12, 50, 90 and 150 Pa in a custom-developed shearing system. Blood samples were exposed to shear for 0, 300, 600 and 900 s. Haemolysis was measured using spectrophotometry, platelet activation using flow cytometry, and HMW vWF multimer degradation was quantified with gel electrophoresis and immunoblotting. For tolerance to 300, 600 and 900 s of exposure time, the critical threshold of haemolysis was reached after blood was exposed to 90 Pa for 600 s (P < 0.05), platelet activation and HMW vWF multimer degradation were 50 Pa for 600 s and 12 Pa for 300 s respectively (P < 0.05). Our experimental results provide simultaneous comparison of blood trauma indices and thus also the relation between shear duration and magnitude required to induce damage to red cells, platelets, and vWF. Our results also demonstrate that near-physiological shear stress (<12 Pa) is needed in order to completely avoid any form of blood trauma. Therefore, there is an urgent need to design low shear-flow medical devices in order to avoid blood trauma in this blood-contacting medical device field.
Collapse
Affiliation(s)
- Chris H H Chan
- School of Engineering and Built Environment, Griffith University, Queensland, Australia; Critical Care Research Group, The Prince Charles Hospital, Queensland, Australia; Faculty of Medicine, University of Queensland, Queensland, Australia.
| | - Michael J Simmonds
- Menzies Health Institute Queensland, Griffith University, Queensland, Australia
| | - Katharine H Fraser
- Department of Mechanical Engineering, University of Bath, Bath, United Kingdom
| | - Kosuke Igarashi
- School of Engineering and Built Environment, Griffith University, Queensland, Australia; Critical Care Research Group, The Prince Charles Hospital, Queensland, Australia; Department of Life Sciences, Systems Engineering and Science, Graduate School of Engineering and Science, Shibaura Institute of Technology, Saitama, Japan
| | - Katrina K Ki
- Critical Care Research Group, The Prince Charles Hospital, Queensland, Australia; Faculty of Medicine, University of Queensland, Queensland, Australia
| | - Tomotaka Murashige
- School of Engineering and Built Environment, Griffith University, Queensland, Australia; School of Engineering, Tokyo Institute of Technology, Tokyo, Japan
| | - Mary T Joseph
- Critical Care Research Group, The Prince Charles Hospital, Queensland, Australia
| | - John F Fraser
- Critical Care Research Group, The Prince Charles Hospital, Queensland, Australia; Faculty of Medicine, University of Queensland, Queensland, Australia; School of Medicine, Griffith University, Queensland, Australia
| | - Geoff D Tansley
- School of Engineering and Built Environment, Griffith University, Queensland, Australia; Critical Care Research Group, The Prince Charles Hospital, Queensland, Australia
| | - Nobuo Watanabe
- Department of Life Sciences, Systems Engineering and Science, Graduate School of Engineering and Science, Shibaura Institute of Technology, Saitama, Japan
| |
Collapse
|
45
|
Ponnaluri S, Christensen E, Good B, Kubicki C, Deutsch S, Cysyk J, Weiss WJ, Manning KB. Experimental Hemodynamics within the Penn State Fontan Circulatory Assist Device. J Biomech Eng 2021; 144:1129243. [PMID: 34897373 DOI: 10.1115/1.4053210] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Indexed: 11/08/2022]
Abstract
For children born with a single functional ventricle, the Fontan operation bypasses the right ventricle by forming a four-way total cavopulmonary connection adapting the existing ventricle for the systemic circulation. However, upon adulthood, many Fontan patients exhibit low cardiac output and elevated venous pressure, eventually requiring a heart transplantation. Despite efforts to develop a Fontan pump or use an existing ventricular assist device for failing Fontan support, there is still no device designed or tested for subpulmonary support. Penn State University is developing a hydrodynamically levitated Fontan circulatory assist device (FCAD) for bridge-to-transplant or destination therapy. The FCAD hemodynamics, at both steady and pulsatile conditions for three pump operating conditions, were quantified using particle image velocimetry to determine the velocity magnitudes and Reynolds normal and shear stresses. Data were acquired at three planes (0 mm and ±25% of the radius) for the inferior and superior vena cavae inlets and the pulmonary artery outlet. The inlets had a blunt velocity profile that became skewed towards the collecting volute as fluid approached the rotor. At the outlet, regardless of the flow condition, a high-velocity jet exited the volute and moved downstream in a helical pattern. Turbulent stresses observed at the volute exit were influenced by the rotor's rotation. Regardless of inlet conditions, the pump demonstrated advantageous behavior for clinical use with a predictable flow field and a low risk of platelet adhesion and hemolysis based on calculated wall shear rates and turbulent stresses, respectively.
Collapse
Affiliation(s)
- Sailahari Ponnaluri
- Department of Biomedical Engineering, Pennsylvania State University, University Park, PA; Suite 122 Chemical and Biomedical Engineering Building, Penn State University, University Park, PA
| | - Emma Christensen
- Department of Biomedical Engineering, Pennsylvania State University, University Park, PA; Suite 122 Chemical and Biomedical Engineering Building, Penn State University, University Park, PA
| | - Bryan Good
- Department of Biomedical Engineering, Pennsylvania State University, University Park, PA; Suite 122 Chemical and Biomedical Engineering Building, Penn State University, University Park, PA
| | - Cody Kubicki
- Department of Biomedical Engineering, Pennsylvania State University, University Park, PA; Suite 122 Chemical and Biomedical Engineering Building, Penn State University, University Park, PA
| | - Steven Deutsch
- Department of Biomedical Engineering, Pennsylvania State University, University Park, PA; Suite 122 Chemical and Biomedical Engineering Building, Penn State University, University Park, PA
| | - Joshua Cysyk
- Department of Surgery, Penn State Hershey Medical Center, PA; H151 Surgery Hershey PA 17033, The Milton S. Hershey Medical Center
| | - William J Weiss
- Department of Surgery, Penn State Hershey Medical Center, PA; H151 Surgery Hershey PA 17033, The Milton S. Hershey Medical Center
| | - Keefe B Manning
- Department of Biomedical Engineering, Pennsylvania State University, University Park, PA, Department of Surgery, Penn State Hershey Medical Center, PA; Suite 122 Chemical and Biomedical Engineering Building, Penn State University, University Park, PA
| |
Collapse
|
46
|
Martinolli M, Cornat F, Vergara C. Computational Fluid-Structure Interaction Study of a New Wave Membrane Blood Pump. Cardiovasc Eng Technol 2021; 13:373-392. [PMID: 34773241 DOI: 10.1007/s13239-021-00584-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Accepted: 10/13/2021] [Indexed: 01/11/2023]
Abstract
PURPOSE Wave membrane blood pumps (WMBP) are novel pump designs in which blood is propelled by means of wave propagation by an undulating membrane. In this paper, we computationally studied the performance of a new WMBP design (J-shaped) for different working conditions, in view of potential applications in human patients. METHODS Fluid-structure interaction (FSI) simulations were conducted in 3D pump geometries and numerically discretized by means of the extended finite element method (XFEM). A contact model was introduced to capture membrane-wall collisions in the pump head. Mean flow rate and membrane envelope were determined to evaluate hydraulic performance. A preliminary hemocompatibility analysis was performed via calculation of fluid shear stress. RESULTS Numerical results, validated against in vitro experimental data, showed that the hydraulic output increases when either the frequency or the amplitude of membrane oscillations were higher, with limited increase in the fluid stresses, suggesting good hemocompatibility properties. Also, we showed better performance in terms of hydraulic power with respect to a previous design of the pump. We finally studied an operating point which achieves physiologic flow rate target at diastolic head pressure of 80 mmHg. CONCLUSION A new design of WMBP was computationally studied. The proposed FSI model with contact was employed to predict the new pump hydraulic performance and it could help to properly select an operating point for the upcoming first-in-human trials.
Collapse
Affiliation(s)
- Marco Martinolli
- MOX, Dipartimento di Matematica, Politecnico di Milano, Milan, Italy
| | | | - Christian Vergara
- LaBS, Dipartimento di Chimica, Materiali e Ingegneria Chimica "Giulio Natta", Politecnico di Milano, Milan, Italy.
| |
Collapse
|
47
|
Karnik S, Smith PA, Ogiwara E, Fraser CD, Frazier OH, Kurita N, Fraser KH, Wang Y. Hemocompatibility Assessment Platform Drive System Design: Trade-off between Motor Performance and Hemolysis. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:5539-5542. [PMID: 34892379 DOI: 10.1109/embc46164.2021.9630400] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Left ventricular assist devices (LVADs) have long been used to treat adults with heart failure, but LVAD options for pediatric patients with heart failure are lacking. Despite the urgent need for long-term, implantable pediatric LVADs, design challenges such as hemolysis, pump thrombosis, and bleeding persist. We have developed a Hemocompatibility Assessment Platform (HAP) to identify blood trauma from individual LVAD components. A HAP would aid in refining pump components before in vivo testing, thereby preventing unnecessary animal sacrifice and reducing development time and cost. So that the HAP does not confound hemolysis data, the HAP drive system consists of an enlarged air-gap motor coupled to a magnetic levitation system. Although it is known that an enlarged air gap motor will have diminished performance, while the larger gap in the motor will cause less blood damage, the trade-offs are not fully characterized. Therefore, in this study we evaluated these trade-offs to determine an optimal rotor diameter for the HAP drive motor. The motor performance was characterized with an experimental method by determining the torque constant for the HAP drive motor with varied rotor diameters. The torque threshold was set as 10 mNm to achieve a nominal current of 3.5A. Hemolysis in the HAP drive motor gap was estimated by calculating scalar shear stress generated in the HAP motor gap analytically and numerically. A design criterion of 30 Pa was selected for scalar shear stress to achieve minimal hemolysis and platelet activation in the HAP drive system.Clinical Relevance- We evaluated a Hemocompatibility Assessment Platform for developing LVAD prototypes that can best balance motor performance and hemocompatibility. This design method can assist with optimizing the drive system during the research stage and illustrates how motor geometry can be tuned to reduce blood trauma.
Collapse
|
48
|
Strauch C, Escher A, Wulff S, Kertzscher U, Zimpfer D, Thamsen PU, Granegger M. Validation of Numerically Predicted Shear Stress-dependent Dissipative Losses Within a Rotary Blood Pump. ASAIO J 2021; 67:1148-1158. [PMID: 34582408 DOI: 10.1097/mat.0000000000001488] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Computational fluid dynamics find widespread application in the development of rotary blood pumps (RBPs). Yet, corresponding simulations rely on shear stress computations that are afflicted with limited resolution while lacking validation. This study aimed at the experimental validation of integral hydraulic properties to analyze global shear stress resolution across the operational range of a novel RBP. Pressure head and impeller torque were numerically predicted based on Unsteady Reynolds-averaged Navier-Stokes (URANS) simulations and validated on a testbench with integrated sensor modalities (flow, pressure, and torque). Validation was performed by linear regression and Bland-Altman analysis across nine operating conditions. In power loss analysis (PLA), in silico hydraulic power losses were derived based on the validated hydraulic quantities and balanced with in silico shear-dependent dissipative power losses. Discrepancies among both terms provided a measure of in silico shear stress resolution. In silico and in vitro data correlated with low discordance in pressure (r = 0.992, RMSE = 1.02 mmHg), torque (r = 0.999, RMSE = 0.034 mNm), and hydraulic power losses (r = 0.990, RMSE = 0.015W). PLA revealed numerically predicted dissipative losses to be up to 34.4% smaller than validated computations of hydraulic losses. This study confirmed the suitability of URANS settings to predict integral hydraulic properties. However, numerical credibility was hampered by lacking resolution of shear-dependent dissipative losses.
Collapse
Affiliation(s)
- Carsten Strauch
- From the Department of Fluid System Dynamics, Technische Universität Berlin, Berlin, Germany
| | - Andreas Escher
- Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria.,Biofluid Mechanics Laboratory, Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Sebastian Wulff
- From the Department of Fluid System Dynamics, Technische Universität Berlin, Berlin, Germany
| | - Ulrich Kertzscher
- Biofluid Mechanics Laboratory, Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Daniel Zimpfer
- Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Paul Uwe Thamsen
- From the Department of Fluid System Dynamics, Technische Universität Berlin, Berlin, Germany
| | - Marcus Granegger
- Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria.,Biofluid Mechanics Laboratory, Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany.,Ludwig-Boltzmann-Cluster for Cardiovascular Research, Vienna, Austria
| |
Collapse
|
49
|
Kelly NS, McCree D, Fresiello L, Brynedal Ignell N, Cookson AN, Najar A, Perkins IL, Fraser KH. Video-based valve motion combined with computational fluid dynamics gives stable and accurate simulations of blood flow in the Realheart total artificial heart. Artif Organs 2021; 46:57-70. [PMID: 34460941 DOI: 10.1111/aor.14056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 07/29/2021] [Accepted: 08/25/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Patients with end-stage, biventricular heart failure, and for whom heart transplantation is not an option, may be given a Total Artificial Heart (TAH). The Realheart® is a novel TAH which pumps blood by mimicking the native heart with translation of an atrioventricular plane. The aim of this work was to create a strategy for using Computational Fluid Dynamics (CFD) to simulate haemodynamics in the Realheart®, including motion of the atrioventricular plane and valves. METHODS The accuracies of four different computational methods for simulating fluid-structure interaction of the prosthetic valves were assessed by comparison of chamber pressures and flow rates with experimental measurements. The four strategies were: prescribed motion of valves opening and closing at the atrioventricular plane extrema; simulation of fluid-structure interaction of both valves; prescribed motion of the mitral valve with simulation of fluid-structure interaction of the aortic valve; motion of both valves prescribed from video analysis of experiments. RESULTS The most accurate strategy (error in ventricular pressure of 6%, error in flow rate of 5%) used video-prescribed motion. With the Realheart operating at 80 bpm, the power consumption was 1.03 W, maximum shear stress was 15 Pa, and washout of the ventricle chamber after 4 cycles was 87%. CONCLUSIONS This study, the first CFD analysis of this novel TAH, demonstrates that good agreement between computational and experimental data can be achieved. This method will therefore enable future optimisation of the geometry and motion of the Realheart®.
Collapse
Affiliation(s)
| | - Danny McCree
- Department of Mechanical Engineering, University of Bath, Bath, UK
| | - Libera Fresiello
- Department of Cardiovascular Sciences, Katholieke Universiteit (KU) Leuven, Leuven, Belgium
| | | | - Andrew N Cookson
- Department of Mechanical Engineering, University of Bath, Bath, UK
| | - Azad Najar
- Scandinavian Real Heart AB, Västerås, Sweden
| | | | | |
Collapse
|
50
|
Woelke E, Mager I, Schmitz-Rode T, Steinseifer U, Clauser JC. Validation of a Miniaturized Test Loop for the Assessment of Human Blood Damage by Continuous-Flow Left-Ventricular Assist Devices. Ann Biomed Eng 2021; 49:3165-3175. [PMID: 34431015 PMCID: PMC8671281 DOI: 10.1007/s10439-021-02849-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 08/04/2021] [Indexed: 11/29/2022]
Abstract
Despite improved hemocompatibility of left-ventricular assist devices (LVADs), assessment of blood damage remains mandatory in preclinical testing as standardized by ASTM-F1841. The most relevant test fluid is fresh, non-pooled human blood, but the limited volume of a standard donation requires significantly smaller loops than those commonly used with animal blood. In a recent study with porcine blood, we verified a miniaturized test loop with only 160 mL for the ASTM-conform paired testing of at least two LVADs and a static reference. Here, we validated this mini test loop for standardized assessment of blood damage with one 450-mL single donation of fresh human blood. Blood damage was assessed for HeartMate 3 and BPX-80 in 9 experiments with heparinized human blood for 6 hours. We analyzed plasma free hemoglobin, von Willebrand factor (vWF) concentration and collagen-binding functionality and calculated indices of hemolysis and vWF-ratios. Overall, we observed less blood damage compared to our previous study; however, the differences in mean indices of hemolysis and in mean normalized vWF-ratio between BPX-80 and HeartMate 3 were consistent for human blood. Thus, our mini test loop proved to be valid for preclinical standardized assessment of blood damage with only 450 mL of fresh human blood.
Collapse
Affiliation(s)
- Eva Woelke
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Ilona Mager
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Thomas Schmitz-Rode
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Johanna C Clauser
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.
| |
Collapse
|