1
|
Varas N, Grabowski R, Jarosinski MA, Tai N, Herzog RI, Ismail-Beigi F, Yang Y, Cherrington AD, Weiss MA. Ultra-stable insulin-glucagon fusion protein exploits an endogenous hepatic switch to mitigate hypoglycemic risk. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.05.20.594997. [PMID: 38826486 PMCID: PMC11142066 DOI: 10.1101/2024.05.20.594997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2024]
Abstract
The risk of hypoglycemia and its serious medical sequelae restrict insulin replacement therapy for diabetes mellitus. Such adverse clinical impact has motivated development of diverse glucose-responsive technologies, including algorithm-controlled insulin pumps linked to continuous glucose monitors ("closed-loop systems") and glucose-sensing ("smart") insulins. These technologies seek to optimize glycemic control while minimizing hypoglycemic risk. Here, we describe an alternative approach that exploits an endogenous glucose-dependent switch in hepatic physiology: preferential insulin signaling (under hyperglycemic conditions) versus preferential counter-regulatory glucagon signaling (during hypoglycemia). Motivated by prior reports of glucagon-insulin co-infusion, we designed and tested an ultra-stable glucagon-insulin fusion protein whose relative hormonal activities were calibrated by respective modifications; physical stability was concurrently augmented to facilitate formulation, enhance shelf life and expand access. An N-terminal glucagon moiety was stabilized by an α-helix-compatible Lys 13 -Glu 17 lactam bridge; A C-terminal insulin moiety was stabilized as a single chain with foreshortened C domain. Studies in vitro demonstrated (a) resistance to fibrillation on prolonged agitation at 37 °C and (b) dual hormonal signaling activities with appropriate balance. Glucodynamic responses were monitored in rats relative to control fusion proteins lacking one or the other hormonal activity, and continuous intravenous infusion emulated basal subcutaneous therapy. Whereas efficacy in mitigating hyperglycemia was unaffected by the glucagon moiety, the fusion protein enhanced endogenous glucose production under hypoglycemic conditions. Together, these findings provide proof of principle toward a basal glucose-responsive insulin biotechnology of striking simplicity. The fusion protein's augmented stability promises to circumvent the costly cold chain presently constraining global insulin access. Significance Statement The therapeutic goal of insulin replacement therapy in diabetes is normalization of blood-glucose concentration, which prevents or delays long-term complications. A critical barrier is posed by recurrent hypoglycemic events that results in short- and long-term morbidities. An innovative approach envisions co-injection of glucagon (a counter-regulatory hormone) to exploit a glycemia-dependent hepatic switch in relative hormone responsiveness. To provide an enabling technology, we describe an ultra-stable fusion protein containing insulin- and glucagon moieties. Proof of principle was obtained in rats. A single-chain insulin moiety provides glycemic control whereas a lactam-stabilized glucagon extension mitigates hypoglycemia. This dual-hormone fusion protein promises to provide a basal formulation with reduced risk of hypoglycemia. Resistance to fibrillation may circumvent the cold chain required for global access.
Collapse
|
2
|
Abraham N, Kolipaka T, Pandey G, Negi M, Srinivasarao DA, Srivastava S. Revolutionizing pancreatic islet organoid transplants: Improving engraftment and exploring future frontiers. Life Sci 2024; 343:122545. [PMID: 38458556 DOI: 10.1016/j.lfs.2024.122545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 02/16/2024] [Accepted: 03/04/2024] [Indexed: 03/10/2024]
Abstract
Type-1 Diabetes Mellitus (T1DM) manifests due to pancreatic beta cell destruction, causing insulin deficiency and hyperglycaemia. Current therapies are inadequate for brittle diabetics, necessitating pancreatic islet transplants, which however, introduces its own set of challenges such as paucity of donors, rigorous immunosuppression and autoimmune rejection. Organoid technology represents a significant stride in the field of regenerative medicine and bypasses donor-based approaches. Hence this article focuses on strategies enhancing the in vivo engraftment of islet organoids (IOs), namely vascularization, encapsulation, immune evasion, alternative extra-hepatic transplant sites and 3D bioprinting. Hypoxia-induced necrosis and delayed revascularization attenuate organoid viability and functional capacity, alleviated by the integration of diverse cell types e.g., human amniotic epithelial cells (hAECs) and human umbilical vein endothelial cells (HUVECs) to boost vascularization. Encapsulation with biocompatible materials and genetic modifications counters immune damage, while extra-hepatic sites avoid surgical complications and immediate blood-mediated inflammatory reactions (IBMIR). Customizable 3D bioprinting may help augment the viability and functionality of IOs. While the clinical translation of IOs faces hurdles, preliminary results show promise. This article underscores the importance of addressing challenges in IO transplantation to advance their use in treating type 1 diabetes effectively.
Collapse
Affiliation(s)
- Noella Abraham
- Pharmaceutical Innovation and Translational Research Lab (PITRL), Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad, India
| | - Tejaswini Kolipaka
- Pharmaceutical Innovation and Translational Research Lab (PITRL), Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad, India
| | - Giriraj Pandey
- Pharmaceutical Innovation and Translational Research Lab (PITRL), Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad, India
| | - Mansi Negi
- Pharmaceutical Innovation and Translational Research Lab (PITRL), Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad, India
| | - Dadi A Srinivasarao
- Pharmaceutical Innovation and Translational Research Lab (PITRL), Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad, India
| | - Saurabh Srivastava
- Pharmaceutical Innovation and Translational Research Lab (PITRL), Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad, India.
| |
Collapse
|
3
|
Oktavian P, Budi DS, Wibowo IN, Rusuldi RCR, Kusumawardhani AD, Wafa IA, Rahman HR, Pratama NR, Mudjanarko SW. Automated glycemic control with a bionic pancreas for type 1 diabetes mellitus: A systematic review and meta-analysis. Diabetes Metab Syndr 2023; 17:102847. [PMID: 37639999 DOI: 10.1016/j.dsx.2023.102847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 08/17/2023] [Accepted: 08/20/2023] [Indexed: 08/31/2023]
Abstract
BACKGROUND AND AIMS The use of a bionic pancreas with automated insulin delivery systems to prevent complications of diabetes mellitus shows conflicting results. We aimed to comprehensively discuss the potential use of a bionic pancreas in patients with type 1 diabetes (T1D). METHODS A systematic database search was conducted on October 24, 2022, for articles investigating the use of a bionic pancreas in patients with T1D. The hemoglobin A1c (HbA1c) level, mean glucose level, glucose coefficient of variability, time-in-range (TIR), and adverse events were investigated. RESULTS Nine studies were included in this review. The data from these studies suggested that the use of a bionic pancreas could reduce the HbA1c (mean difference [MD] = -0.40% [95% confidence interval {CI} = -0.59 to -0.21], I2 = 0%, p < 0.0001) and mean glucose levels (MD = -21.06 [95% CI = -24.66 to -17.46], I2 = 45%, p < 0.00001) and improve the TIR (MD = 14.41% [95% CI = 10.99 to 17.83], I2 = 60%, p < 0.00001). The most common adverse events reported were nausea and vomiting. CONCLUSIONS The use of a bionic pancreas shows potential in preventing complications of T1D by improving the TIR and decreasing the HbA1c and mean glucose levels. Furthermore, serious adverse events with the use of a bionic pancreas and standard of care show insignificant results, suggesting a good safety profile.
Collapse
Affiliation(s)
- Puguh Oktavian
- Faculty of Medicine Universitas Airlangga, Surabaya, Indonesia
| | | | | | | | | | - Ifan Ali Wafa
- Faculty of Medicine Universitas Airlangga, Surabaya, Indonesia
| | | | | | - Sony Wibisono Mudjanarko
- Division of Endocrinology, Metabolism, and Diabetes, Department of Internal Medicine, Dr. Soetomo General Academic Hospital, Faculty of Medicine Universitas Airlangga, Surabaya, Indonesia.
| |
Collapse
|
4
|
Furió-Novejarque C, Sanz R, Ritschel TKS, Reenberg AT, Ranjan AG, Nørgaard K, Díez JL, Jørgensen JB, Bondia J. Modeling the effect of glucagon on endogenous glucose production in type 1 diabetes: On the role of glucagon receptor dynamics. Comput Biol Med 2023; 154:106605. [PMID: 36731362 DOI: 10.1016/j.compbiomed.2023.106605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 01/19/2023] [Accepted: 01/22/2023] [Indexed: 01/26/2023]
Abstract
This paper validates a glucoregulatory model including glucagon receptors dynamics in the description of endogenous glucose production (EGP). A set of models from literature are selected for a head-to-head comparison in order to evaluate the role of glucagon receptors. Each EGP model is incorporated into an existing glucoregulatory model and validated using a set of clinical data, where both insulin and glucagon are administered. The parameters of each EGP model are identified in the same optimization problem, minimizing the root mean square error (RMSE) between the simulation and the clinical data. The results show that the RMSE for the proposed receptors-based EGP model was lower when compared to each of the considered models (Receptors approach: 7.13±1.71 mg/dl vs. 7.76±1.45 mg/dl (p=0.066), 8.45±1.38 mg/dl (p=0.011) and 8.99±1.62 mg/dl (p=0.007)). This raises the possibility of considering glucagon receptors dynamics in type 1 diabetes simulators.
Collapse
Affiliation(s)
- Clara Furió-Novejarque
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, C/Camí de Vera, s/n, València, 46022, Spain.
| | - Ricardo Sanz
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, C/Camí de Vera, s/n, València, 46022, Spain.
| | - Tobias K S Ritschel
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Anker Engelunds Vej 1, Kgs. Lyngby, 2800, Denmark.
| | - Asbjørn Thode Reenberg
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Anker Engelunds Vej 1, Kgs. Lyngby, 2800, Denmark.
| | - Ajenthen G Ranjan
- Steno Diabetes Center Copenhagen, Borgmester Ib Juuls Vej 83, Herlev, 2730, Denmark; Danish Diabetes Academy, Søndre Blvd. 29, Odense, 5000, Denmark.
| | - Kirsten Nørgaard
- Steno Diabetes Center Copenhagen, Borgmester Ib Juuls Vej 83, Herlev, 2730, Denmark.
| | - José-Luis Díez
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, C/Camí de Vera, s/n, València, 46022, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Instituto de Salud Carlos III, Av. Monforte de Lemos, 3-5, Madrid, 28029, Spain.
| | - John Bagterp Jørgensen
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Anker Engelunds Vej 1, Kgs. Lyngby, 2800, Denmark.
| | - Jorge Bondia
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, C/Camí de Vera, s/n, València, 46022, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Instituto de Salud Carlos III, Av. Monforte de Lemos, 3-5, Madrid, 28029, Spain.
| |
Collapse
|
5
|
Lindkvist EB, Laugesen C, Reenberg AT, Ritschel TKS, Svensson J, Jørgensen JB, Nørgaard K, Ranjan AG. Performance of a dual-hormone closed-loop system versus insulin-only closed-loop system in adolescents with type 1 diabetes. A single-blind, randomized, controlled, crossover trial. Front Endocrinol (Lausanne) 2023; 14:1073388. [PMID: 36755913 PMCID: PMC9899880 DOI: 10.3389/fendo.2023.1073388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Accepted: 01/09/2023] [Indexed: 01/25/2023] Open
Abstract
Objective To assess the efficacy and safety of a dual-hormone (DH [insulin and glucagon]) closed-loop system compared to a single-hormone (SH [insulin only]) closed-loop system in adolescents with type 1 diabetes. Methods This was a 26-hour, two-period, randomized, crossover, inpatient study involving 11 adolescents with type 1 diabetes (nine males [82%], mean ± SD age 14.8 ± 1.4 years, diabetes duration 5.7 ± 2.3 years). Except for the treatment configuration of the DiaCon Artificial Pancreas: DH or SH, experimental visits were identical consisting of: an overnight stay (10:00 pm until 7:30 am), several meals/snacks, and a 45-minute bout of moderate intensity continuous exercise. The primary endpoint was percentage of time spent with sensor glucose values below range (TBR [<3.9 mmol/L]) during closed-loop control over the 26-h period (5:00 pm, day 1 to 7:00 pm, day 2). Results Overall, there were no differences between DH and SH for the following glycemic outcomes (median [IQR]): TBR 1.6 [0.0, 2.4] vs. 1.28 [0.16, 3.19]%, p=1.00; time in range (TIR [3.9-10.0 mmol/L]) 68.4 [48.7, 76.8] vs. 75.7 [69.8, 87.1]%, p=0.08; and time above range (TAR [>10.0 mmol/L]) 28.1 [18.1, 49.8] vs. 23.3 [12.3, 27.2]%, p=0.10. Mean ( ± SD) glucose was higher during DH than SH (8.7 ( ± 3.2) vs. 8.1 ( ± 3.0) mmol/L, p<0.001) but coefficient of variation was similar (34.8 ( ± 6.8) vs. 37.3 ( ± 8.6)%, p=0.20). The average amount of rescue carbohydrates was similar between DH and SH (6.8 ( ± 12.3) vs. 9.5 ( ± 15.4) grams/participant/visit, p=0.78). Overnight, TIR was higher, TAR was lower during the SH visit compared to DH. During and after exercise (4:30 pm until 7 pm) the SH configuration produced higher TIR, but similar TAR and TBR compared to the DH configuration. Conclusions DH and SH performed similarly in adolescents with type 1 diabetes during a 26-hour inpatient monitoring period involving several metabolic challenges including feeding and exercise. However, during the night and around exercise, the SH configuration outperformed DH.
Collapse
Affiliation(s)
- Emilie Bundgaard Lindkvist
- Copenhagen University Hospital - Steno Diabetes Center Copenhagen, Herlev, Denmark
- Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Christian Laugesen
- Copenhagen University Hospital - Steno Diabetes Center Copenhagen, Herlev, Denmark
- Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Asbjørn Thode Reenberg
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - Tobias Kasper Skov Ritschel
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - Jannet Svensson
- Copenhagen University Hospital - Steno Diabetes Center Copenhagen, Herlev, Denmark
- Department of Pediatrics, Herlev and Gentofte University Hospital, Herlev, Denmark
| | - John Bagterp Jørgensen
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - Kirsten Nørgaard
- Copenhagen University Hospital - Steno Diabetes Center Copenhagen, Herlev, Denmark
- Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Ajenthen G. Ranjan
- Copenhagen University Hospital - Steno Diabetes Center Copenhagen, Herlev, Denmark
- Danish Diabetes Academy, Odense, Denmark
| |
Collapse
|
6
|
Ware J, Hovorka R. Closed-loop insulin delivery: update on the state of the field and emerging technologies. Expert Rev Med Devices 2022; 19:859-875. [PMID: 36331211 PMCID: PMC9780196 DOI: 10.1080/17434440.2022.2142556] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 10/28/2022] [Indexed: 11/06/2022]
Abstract
INTRODUCTION Over the last five years, closed-loop insulin delivery systems have transitioned from research-only to real-life use. A number of systems have been commercialized and are increasingly used in clinical practice. Given the rapidity of new developments in the field, understanding the capabilities and key similarities and differences of current systems can be challenging. This review aims to provide an update on the state of the field of closed-loop insulin delivery systems, including emerging technologies. AREAS COVERED We summarize key clinical safety and efficacy evidence of commercial and emerging insulin-only hybrid closed-loop systems for type 1 diabetes. A literature search was conducted and clinical trials using closed-loop systems during free-living conditions were identified to report on safety and efficacy data. We comment on emerging technologies and adjuncts for closed-loop systems, as well as non-technological priorities in closed-loop insulin delivery. EXPERT OPINION Commercial hybrid closed-loop insulin delivery systems are efficacious, consistently improving glycemic control when compared to standard therapy. Challenges remain in widespread adoption due to clinical inertia and the lack of resources to embrace technological developments by health care professionals.
Collapse
Affiliation(s)
- Julia Ware
- Wellcome Trust-MRC Institute of Metabolic Science, University of Cambridge, Cambridge, United Kingdom
- Department of Pediatrics, University of Cambridge, Cambridge, United Kingdom
| | - Roman Hovorka
- Wellcome Trust-MRC Institute of Metabolic Science, University of Cambridge, Cambridge, United Kingdom
- Department of Pediatrics, University of Cambridge, Cambridge, United Kingdom
| |
Collapse
|
7
|
Ju Y, Zhang D, Yang J. Dasiglucagon for treating severe hypoglycemia in patients with diabetes. Expert Rev Clin Pharmacol 2022; 15:799-803. [PMID: 35848442 DOI: 10.1080/17512433.2022.2103537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Affiliation(s)
- Yongjing Ju
- Department of Pharmaceutical, Central Hospital of Linyi City, Yishui Shandong, China
| | - Duzhen Zhang
- Department Ophthalmology, Central Hospital of Linyi City, Yishui Shandong, China
| | - Junyi Yang
- Department of Pharmaceutical, Central Hospital of Linyi City, Yishui Shandong, China
| |
Collapse
|
8
|
Fushimi E, De Battista H, Garelli F. A Dual-Hormone Multicontroller for Artificial Pancreas Systems. IEEE J Biomed Health Inform 2022; 26:4743-4750. [PMID: 35704538 DOI: 10.1109/jbhi.2022.3182581] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Artificial pancreas (AP) algorithms can be divided into single-hormone (SH) and dual-hormone (DH). SH algorithms regulate glycemia using insulin as their control input. On the other hand, DH algorithms also use glucagon to counteract insulin. While SH-AP systems are already commercially available, DH-AP systems are still in an earlier research phase. DH-AP systems have been questioned since the added complexity of glucagon infusion does not always guarantee hypoglycemia prevention and might significantly raise insulin delivery. In this work, a DH multicontroller is proposed based on a SH linear quadratic gaussian (LQG) algorithm with an additional LQG controller to deliver glucagon. This strategy has a switched structure that allows activating one of the following three controllers when necessary: a conservative insulin LQG controller to modulate basal delivery ( K1), an aggressive insulin LQG controller to counteract meals ( K2), or a glucagon LQG controller to avoid imminent hypoglycemia ( K3). Here, an in silico study of the benefits of incorporating controller K3 is carried out. Intra-patient variability and mixed meals are considered. Results indicate that the proposed switched, dual-hormone strategy yields to a reduction in hypoglycemia without increasing hyperglycemia, with no significant rise in insulin delivery.
Collapse
|
9
|
Hettiarachchi C, Daskalaki E, Desborough J, Nolan CJ, O'Neal D, Suominen H. Integrating Multiple Inputs Into an Artificial Pancreas System: Narrative Literature Review. JMIR Diabetes 2022; 7:e28861. [PMID: 35200143 PMCID: PMC8914747 DOI: 10.2196/28861] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 06/07/2021] [Accepted: 01/01/2022] [Indexed: 12/02/2022] Open
Abstract
Background Type 1 diabetes (T1D) is a chronic autoimmune disease in which a deficiency in insulin production impairs the glucose homeostasis of the body. Continuous subcutaneous infusion of insulin is a commonly used treatment method. Artificial pancreas systems (APS) use continuous glucose level monitoring and continuous subcutaneous infusion of insulin in a closed-loop mode incorporating a controller (or control algorithm). However, the operation of APS is challenging because of complexities arising during meals, exercise, stress, sleep, illnesses, glucose sensing and insulin action delays, and the cognitive burden. To overcome these challenges, options to augment APS through integration of additional inputs, creating multi-input APS (MAPS), are being investigated. Objective The aim of this survey is to identify and analyze input data, control architectures, and validation methods of MAPS to better understand the complexities and current state of such systems. This is expected to be valuable in developing improved systems to enhance the quality of life of people with T1D. Methods A literature survey was conducted using the Scopus, PubMed, and IEEE Xplore databases for the period January 1, 2005, to February 10, 2020. On the basis of the search criteria, 1092 articles were initially shortlisted, of which 11 (1.01%) were selected for an in-depth narrative analysis. In addition, 6 clinical studies associated with the selected studies were also analyzed. Results Signals such as heart rate, accelerometer readings, energy expenditure, and galvanic skin response captured by wearable devices were the most frequently used additional inputs. The use of invasive (blood or other body fluid analytes) inputs such as lactate and adrenaline were also simulated. These inputs were incorporated to switch the mode of the controller through activity detection, directly incorporated for decision-making and for the development of intermediate modules for the controller. The validation of the MAPS was carried out through the use of simulators based on different physiological models and clinical trials. Conclusions The integration of additional physiological signals with continuous glucose level monitoring has the potential to optimize glucose control in people with T1D through addressing the identified limitations of APS. Most of the identified additional inputs are related to wearable devices. The rapid growth in wearable technologies can be seen as a key motivator regarding MAPS. However, it is important to further evaluate the practical complexities and psychosocial aspects associated with such systems in real life.
Collapse
Affiliation(s)
- Chirath Hettiarachchi
- School of Computing, College of Engineering and Computer Science, The Australian National University, Canberra, Australia
| | - Elena Daskalaki
- School of Computing, College of Engineering and Computer Science, The Australian National University, Canberra, Australia
| | - Jane Desborough
- Department of Health Services Research and Policy, Research School of Population Health, College of Health and Medicine, The Australian National University, Canberra, Australia
| | - Christopher J Nolan
- Australian National University Medical School, College of Health and Medicine, The Australian National University, Canberra, Australia.,John Curtin School of Medical Research, College of Health and Medicine, The Australian National University, Canberra, Australia
| | - David O'Neal
- Department of Medicine, University of Melbourne, Melbourne, Australia.,Department of Endocrinology and Diabetes, St Vincent's Hospital Melbourne, Melbourne, Australia
| | - Hanna Suominen
- School of Computing, College of Engineering and Computer Science, The Australian National University, Canberra, Australia.,Data61, Commonwealth Industrial and Scientific Research Organisation, Canberra, Australia.,Department of Computing, University of Turku, Turku, Finland
| |
Collapse
|
10
|
Ware J, Hovorka R. Recent advances in closed-loop insulin delivery. Metabolism 2022; 127:154953. [PMID: 34890648 PMCID: PMC8792215 DOI: 10.1016/j.metabol.2021.154953] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Revised: 11/05/2021] [Accepted: 11/24/2021] [Indexed: 02/03/2023]
Abstract
Since the discovery of insulin 100 years ago, we have seen considerable advances across diabetes therapies. The more recent advent of glucose-responsive automated insulin delivery has started to revolutionise the management of type 1 diabetes in children and adults. Evolution of closed-loop insulin delivery from research to clinical practice has been rapid, and multiple systems are now commercially available. In this review, we summarise key evidence on currently available closed-loop systems and those in development. We comment on dual-hormone and do-it-yourself systems, as well as reviewing clinical evidence in special populations such as very young children, older adults and in pregnancy. We identify future directions for research and barriers to closed-loop adoption, including how these might be addressed to ensure equitable access to this novel therapy.
Collapse
Affiliation(s)
- Julia Ware
- Wellcome Trust-MRC Institute of Metabolic Science, University of Cambridge, Cambridge, United Kingdom; Department of Paediatrics, University of Cambridge, Cambridge, United Kingdom
| | - Roman Hovorka
- Wellcome Trust-MRC Institute of Metabolic Science, University of Cambridge, Cambridge, United Kingdom; Department of Paediatrics, University of Cambridge, Cambridge, United Kingdom.
| |
Collapse
|
11
|
Templer S. Closed-Loop Insulin Delivery Systems: Past, Present, and Future Directions. Front Endocrinol (Lausanne) 2022; 13:919942. [PMID: 35733769 PMCID: PMC9207329 DOI: 10.3389/fendo.2022.919942] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 05/06/2022] [Indexed: 12/16/2022] Open
Abstract
Closed-loop (artificial pancreas) systems for automated insulin delivery have been likened to the holy grail of diabetes management. The first iterations of glucose-responsive insulin delivery were pioneered in the 1960s and 1970s, with the development of systems that used venous glucose measurements to dictate intravenous infusions of insulin and dextrose in order to maintain normoglycemia. Only recently have these bulky, bedside technologies progressed to miniaturized, wearable devices. These modern closed-loop systems use interstitial glucose sensing, subcutaneous insulin pumps, and increasingly sophisticated algorithms. As the number of commercially available hybrid closed-loop systems has grown, so too has the evidence supporting their efficacy. Future challenges in closed-loop technology include the development of fully closed-loop systems that do not require user input for meal announcements or carbohydrate counting. Another evolving avenue in research is the addition of glucagon to mitigate the risk of hypoglycemia and allow more aggressive insulin dosing.
Collapse
|
12
|
Pinnaro CT, Tansey MJ. The Evolution of Insulin Administration in Type 1 Diabetes. JOURNAL OF DIABETES MELLITUS 2021; 11:249-277. [PMID: 37745178 PMCID: PMC10516284 DOI: 10.4236/jdm.2021.115021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 09/26/2023]
Abstract
Insulin has been utilized in the treatment of type 1 diabetes (T1D) for 100 years. While there is still no cure for T1D, insulin administration has undergone a remarkable evolution which has contributed to improvements in quality of life and life expectancy in individuals with T1D. The advent of faster-acting and longer-acting insulins allowed for the implementation of insulin regimens more closely resembling normal insulin physiology. These improvements afforded better glycemic control, which is crucial for limiting microvascular complications and improving T1D outcomes. Suspension of insulin delivery in response to actual and forecasted hypoglycemia has improved quality of life and mitigated hypoglycemia without compromising glycemic control. Advances in continuous glucose monitoring (CGM) and insulin pumps, efforts to model glucose and insulin kinetics, and the application of control theory to T1D have made the automation of insulin delivery a reality. This review will summarize the past, present, and future of insulin administration in T1D.
Collapse
Affiliation(s)
- Catherina T Pinnaro
- University of Iowa Stead Family Department of Pediatrics
- Fraternal Order of Eagles Diabetes Research Center
| | - Michael J Tansey
- University of Iowa Stead Family Department of Pediatrics
- Fraternal Order of Eagles Diabetes Research Center
| |
Collapse
|
13
|
Infante M, Baidal DA, Rickels MR, Fabbri A, Skyler JS, Alejandro R, Ricordi C. Dual-hormone artificial pancreas for management of type 1 diabetes: Recent progress and future directions. Artif Organs 2021; 45:968-986. [PMID: 34263961 DOI: 10.1111/aor.14023] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 06/09/2021] [Accepted: 06/14/2021] [Indexed: 02/06/2023]
Abstract
Over the last few years, technological advances have led to tremendous improvement in the management of type 1 diabetes (T1D). Artificial pancreas systems have been shown to improve glucose control compared with conventional insulin pump therapy. However, clinically significant hypoglycemic and hyperglycemic episodes still occur with the artificial pancreas. Postprandial glucose excursions and exercise-induced hypoglycemia represent major hurdles in improving glucose control and glucose variability in many patients with T1D. In this regard, dual-hormone artificial pancreas systems delivering other hormones in addition to insulin (glucagon or amylin) may better reproduce the physiology of the endocrine pancreas and have been suggested as an alternative tool to overcome these limitations in clinical practice. In addition, novel ultra-rapid-acting insulin analogs with a more physiological time-action profile are currently under investigation for use in artificial pancreas devices, aiming to address the unmet need for further improvements in postprandial glucose control. This review article aims to discuss the current progress and future outlook in the development of novel ultra-rapid insulin analogs and dual-hormone closed-loop systems, which offer the next steps to fully closing the loop in the artificial pancreas.
Collapse
Affiliation(s)
- Marco Infante
- Clinical Cell Transplant Program, Diabetes Research Institute, University of Miami Miller School of Medicine, Miami, FL, USA.,Division of Endocrinology, Metabolism and Diabetes, Department of Systems Medicine, CTO A. Alesini Hospital, Diabetes Research Institute Federation, University of Rome Tor Vergata, Rome, Italy.,UniCamillus, Saint Camillus International University of Health Sciences, Rome, Italy
| | - David A Baidal
- Clinical Cell Transplant Program, Diabetes Research Institute, University of Miami Miller School of Medicine, Miami, FL, USA.,Division of Endocrinology, Diabetes and Metabolism, Department of Medicine, Diabetes Research Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Michael R Rickels
- Division of Endocrinology, Diabetes and Metabolism, Department of Medicine, Institute for Diabetes, Obesity and Metabolism, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA, USA
| | - Andrea Fabbri
- Division of Endocrinology, Metabolism and Diabetes, Department of Systems Medicine, CTO A. Alesini Hospital, Diabetes Research Institute Federation, University of Rome Tor Vergata, Rome, Italy
| | - Jay S Skyler
- Division of Endocrinology, Diabetes and Metabolism, Department of Medicine, Diabetes Research Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Rodolfo Alejandro
- Clinical Cell Transplant Program, Diabetes Research Institute, University of Miami Miller School of Medicine, Miami, FL, USA.,Division of Endocrinology, Diabetes and Metabolism, Department of Medicine, Diabetes Research Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Camillo Ricordi
- Clinical Cell Transplant Program, Diabetes Research Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| |
Collapse
|
14
|
Blauw H, Onvlee AJ, Klaassen M, van Bon AC, DeVries JH. Fully Closed Loop Glucose Control With a Bihormonal Artificial Pancreas in Adults With Type 1 Diabetes: An Outpatient, Randomized, Crossover Trial. Diabetes Care 2021; 44:836-838. [PMID: 33397767 DOI: 10.2337/dc20-2106] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Accepted: 11/24/2020] [Indexed: 02/03/2023]
Abstract
OBJECTIVE To demonstrate the performance and safety of a bihormonal (insulin and glucagon) artificial pancreas (AP) in adults with type 1 diabetes. RESEARCH DESIGN AND METHODS In this outpatient, randomized, crossover trial, 2-week fully closed loop glucose control (AP therapy) was compared with 2-week open loop control (patient's normal insulin pump therapy with a glucose sensor if they had one). RESULTS A total of 23 patients were included in the analysis. Time in range (70-180 mg/dL [3.9-10 mmol/L]) was significantly higher during closed loop (median 86.6% of time [interquartile range 84.9-88.5]) compared with open loop (53.9% [49.7-67.2]; P < 0.0001). CONCLUSIONS Compared with insulin pump therapy, the bihormonal AP provided superior glucose control, without meal or exercise announcements, and was safe in adults with type 1 diabetes.
Collapse
Affiliation(s)
- Helga Blauw
- Department of Internal Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands .,Inreda Diabetic, Goor, the Netherlands
| | - A Joannet Onvlee
- Inreda Diabetic, Goor, the Netherlands.,Department of Internal Medicine, Rijnstate Hospital, Arnhem, the Netherlands
| | | | - Arianne C van Bon
- Department of Internal Medicine, Rijnstate Hospital, Arnhem, the Netherlands
| | - J Hans DeVries
- Department of Internal Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands
| |
Collapse
|
15
|
Majdpour D, Tsoukas MA, Yale JF, El Fathi A, Rutkowski J, Rene J, Garfield N, Legault L, Haidar A. Fully Automated Artificial Pancreas for Adults With Type 1 Diabetes Using Multiple Hormones: Exploratory Experiments. Can J Diabetes 2021; 45:734-742. [PMID: 33888413 DOI: 10.1016/j.jcjd.2021.02.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 02/11/2021] [Accepted: 02/14/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVES A fully automated insulin-pramlintide-glucagon artificial pancreas that alleviates the burden of carbohydrate counting without degrading glycemic control was iteratively enhanced until convergence through pilot experiments on adults with type 1 diabetes. METHODS Nine participants (age, 37±13 years; glycated hemoglobin, 7.7±0.7%) completed two 27-hour interventions: a fully automated multihormone artificial pancreas and a comparator insulin-alone artificial pancreas with carbohydrate counting. The baseline algorithm was a model-predictive controller that administered insulin and pramlintide in a fixed ratio, with boluses triggered by a glucose threshold, and administered glucagon in response to low glucose levels. RESULTS The baseline multihormone dosing algorithm resulted in noninferior time in target range (3.9 to 10.0 mmol/L) (71%) compared with the insulin-alone arm (70%) in 2 participants, with minimal glucagon delivery. The algorithm was modified to deliver insulin and pramlintide more aggressively to increase time in range and maximize the benefits of glucagon. The modified algorithm displayed a similar time in range for the multihormone arm (79%) compared with the insulin-alone arm (83%) in 2 participants, but with undesired glycemic fluctuations. Subsequently, we reduced the glucose threshold that triggers glucagon boluses. This resulted in inferior glycemic control for the multihormone arm (81% vs 91%) in 2 participants. Thereafter, a model-based meal-detection algorithm to deliver insulin and pramlintide boluses closer to mealtimes was added and glucagon was removed. The final dual-hormone system had comparable time in range (81% vs 83%) in the last 3 participants. CONCLUSION The final version of the fully automated system that delivered insulin and pramlintide warrants a randomized controlled trial.
Collapse
Affiliation(s)
- Dorsa Majdpour
- Department of Biomedical Engineering, McGill University, Montréal, Québec, Canada; The Research Institute of McGill University Health Centre, Montréal, Québec, Canada
| | - Michael A Tsoukas
- The Research Institute of McGill University Health Centre, Montréal, Québec, Canada; Royal Victoria Hospital, McGill University Health Centre, Montréal, Québec, Canada
| | - Jean-François Yale
- The Research Institute of McGill University Health Centre, Montréal, Québec, Canada; Royal Victoria Hospital, McGill University Health Centre, Montréal, Québec, Canada
| | - Anas El Fathi
- Department of Biomedical Engineering, McGill University, Montréal, Québec, Canada
| | - Joanna Rutkowski
- Department of Biomedical Engineering, McGill University, Montréal, Québec, Canada
| | - Jennifer Rene
- Royal Victoria Hospital, McGill University Health Centre, Montréal, Québec, Canada
| | - Natasha Garfield
- Royal Victoria Hospital, McGill University Health Centre, Montréal, Québec, Canada
| | - Laurent Legault
- The Research Institute of McGill University Health Centre, Montréal, Québec, Canada; Montreal Children's Hospital, McGill University Health Centre, Montréal, Québec, Canada
| | - Ahmad Haidar
- Department of Biomedical Engineering, McGill University, Montréal, Québec, Canada.
| |
Collapse
|
16
|
Wang Z, Wang J, Kahkoska AR, Buse JB, Gu Z. Developing Insulin Delivery Devices with Glucose Responsiveness. Trends Pharmacol Sci 2021; 42:31-44. [PMID: 33250274 PMCID: PMC7758938 DOI: 10.1016/j.tips.2020.11.002] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 11/03/2020] [Accepted: 11/03/2020] [Indexed: 12/18/2022]
Abstract
Individuals with type 1 and advanced type 2 diabetes require daily insulin therapy to maintain blood glucose levels in normoglycemic ranges to prevent associated morbidity and mortality. Optimal insulin delivery should offer both precise dosing in response to real-time blood glucose levels as well as a feasible and low-burden administration route to promote long-term adherence. A series of glucose-responsive insulin delivery mechanisms and devices have been reported to increase patient compliance while mitigating the risk of hypoglycemia. This review discusses currently available insulin delivery devices, overviews recent developments towards the generation of glucose-responsive delivery systems, and provides commentary on the opportunities and barriers ahead regarding the integration and translation of current glucose-responsive insulin delivery designs.
Collapse
Affiliation(s)
- Zejun Wang
- Department of Bioengineering, University of California, Los Angeles, CA 90095, USA; Jonsson Comprehensive Cancer Center, University of California, Los Angeles, CA 90095, USA
| | - Jinqiang Wang
- Department of Bioengineering, University of California, Los Angeles, CA 90095, USA; Jonsson Comprehensive Cancer Center, University of California, Los Angeles, CA 90095, USA; College of Pharmaceutical Sciences, Zhejiang University, 310058 Hangzhou, China
| | - Anna R Kahkoska
- Department of Medicine, University of North Carolina School of Medicine, Chapel Hill, NC 27599, USA
| | - John B Buse
- Department of Medicine, University of North Carolina School of Medicine, Chapel Hill, NC 27599, USA.
| | - Zhen Gu
- Department of Bioengineering, University of California, Los Angeles, CA 90095, USA; Jonsson Comprehensive Cancer Center, University of California, Los Angeles, CA 90095, USA; College of Pharmaceutical Sciences, Zhejiang University, 310058 Hangzhou, China; California NanoSystems Institute, University of California, Los Angeles, CA 90095, USA.
| |
Collapse
|
17
|
Åm MK, Dirnena-Fusini I, Fougner AL, Carlsen SM, Christiansen SC. Intraperitoneal and subcutaneous glucagon delivery in anaesthetized pigs: effects on circulating glucagon and glucose levels. Sci Rep 2020; 10:13735. [PMID: 32792580 PMCID: PMC7426268 DOI: 10.1038/s41598-020-70813-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Accepted: 07/07/2020] [Indexed: 12/18/2022] Open
Abstract
Glucagon is a pancreatic hormone and increases the blood glucose levels. It may be incorporated in a dual hormone artificial pancreas, a device to automatically and continuously control blood glucose levels of individuals with diabetes. Artificial pancreas systems have been developed for use in the subcutaneous tissue; however, the systems are not fully automated due to slow dynamics. The intraperitoneal space is therefore investigated as an alternative location for an artificial pancreas. Glucose dynamics after subcutaneous and intraperitoneal glucagon delivery in ten anaesthetized pigs were investigated. The pigs received intraperitoneal boluses of 0.3 µg/kg and 0.6 µg/kg and a subcutaneous bolus of 0.6 µg/kg in randomized order. They also received an intraperitoneal bolus of 1 mg given at the end of the experiments to test the remaining capacity of rapid glucose release. Six pigs were included in the statistical analysis. The intraperitoneal glucagon bolus of 0.6 µg/kg gave a significantly higher glucose response from 14 to 30 min compared with the subcutaneous bolus. The results indicate that glucagon induces a larger glucose response after intraperitoneal delivery compared with subcutaneous delivery and is encouraging for the incorporation of glucagon in an intraperitoneal artificial pancreas.
Collapse
Affiliation(s)
- Marte Kierulf Åm
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology (NTNU), Postboks 8905, 7491, Trondheim, Norway. .,Department of Endocrinology, St Olav's Hospital, Trondheim, Norway.
| | - Ilze Dirnena-Fusini
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology (NTNU), Postboks 8905, 7491, Trondheim, Norway.,Department of Endocrinology, St Olav's Hospital, Trondheim, Norway
| | - Anders Lyngvi Fougner
- Department of Engineering Cybernetics, Faculty of Information Technology and Electrical Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | - Sven Magnus Carlsen
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology (NTNU), Postboks 8905, 7491, Trondheim, Norway.,Department of Endocrinology, St Olav's Hospital, Trondheim, Norway
| | - Sverre Christian Christiansen
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology (NTNU), Postboks 8905, 7491, Trondheim, Norway.,Department of Endocrinology, St Olav's Hospital, Trondheim, Norway
| |
Collapse
|
18
|
Kapil S, Saini R, Wangnoo S, Dhir S. Artificial Pancreas System for Type 1 Diabetes—Challenges and Advancements. EXPLORATORY RESEARCH AND HYPOTHESIS IN MEDICINE 2020; 000:1-11. [DOI: 10.14218/erhm.2020.00028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
19
|
Pedersen C, Kraft G, Edgerton DS, Scott M, Farmer B, Smith M, Laneve DC, Williams PE, Moore LM, Cherrington AD. The kinetics of glucagon action on the liver during insulin-induced hypoglycemia. Am J Physiol Endocrinol Metab 2020; 318:E779-E790. [PMID: 32208001 PMCID: PMC7272728 DOI: 10.1152/ajpendo.00466.2019] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Glucagon's effect on hepatic glucose production (HGP), under hyperglycemic conditions, is time dependent such that after an initial burst of HGP, it slowly wanes. It is not known whether this is also the case under hypoglycemic conditions, where an increase in HGP is essential. This question was addressed using adrenalectomized dogs to avoid the confounding effects of other counterregulatory hormones. During the study, infusions of epinephrine and cortisol were given to maintain basal levels. Somatostatin and insulin (800 µU·kg-1·min-1) were infused to induce hypoglycemia. After 30 min, glucagon was infused at a basal rate (1 ng·kg-1·min-1, baGGN group, n = 5 dogs) or a rate eightfold basal (8 ng·kg-1·min-1, hiGGN group, n = 5 dogs) for 4 h. Glucose was infused to match the arterial glucose levels between groups (≈50 mg/dL). Our data showed that glucagon has a biphasic effect on the liver despite hypoglycemia. Hyperglucagonemia stimulated a rapid, transient peak in HGP (4-fold basal production) over ~60 min, which was followed by a slow reduction in HGP to a rate 1.5-fold basal. During the last 2 h of the experiment, hiGGN stimulated glucose production at a rate fivefold greater than baGGN (2.5 vs. 0.5 mg·kg-1·min-1, respectively), indicating a sustained effect of the hormone. Of note, the hypoglycemia-induced rises in norepinephrine and glycerol were smaller in hiGGN compared with the baGGN group despite identical hypoglycemia. This finding suggests that there is reciprocity between glucagon and the sympathetic nervous system such that when glucagon is increased, the sympathetic nervous response to hypoglycemia is downregulated.
Collapse
Affiliation(s)
| | - Guillaume Kraft
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, Tennessee
| | - Dale S Edgerton
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, Tennessee
| | - Melanie Scott
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, Tennessee
| | - Ben Farmer
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, Tennessee
| | - Marta Smith
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, Tennessee
| | - David C Laneve
- Section of Surgical Sciences, Vanderbilt University School of Medicine, Nashville, Tennessee
| | - Phillip E Williams
- Section of Surgical Sciences, Vanderbilt University School of Medicine, Nashville, Tennessee
| | - L Merkle Moore
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, Tennessee
| | - Alan D Cherrington
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, Tennessee
| |
Collapse
|
20
|
Measuring glucose at the site of insulin delivery with a redox-mediated sensor. Biosens Bioelectron 2020; 165:112221. [PMID: 32729464 DOI: 10.1016/j.bios.2020.112221] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Revised: 04/14/2020] [Accepted: 04/15/2020] [Indexed: 11/22/2022]
Abstract
Automated insulin delivery systems for people with type 1 diabetes rely on an accurate subcutaneous glucose sensor and an infusion cannula that delivers insulin in response to measured glucose. Integrating the sensor with the infusion cannula would provide substantial benefit by reducing the number of devices inserted into subcutaneous tissue. We describe the sensor chemistry and a calibration algorithm to minimize impact of insulin delivery artifacts in a new glucose sensing cannula. Seven people with type 1 diabetes undergoing automated insulin delivery used two sensing cannulae whereby one delivered a rapidly-acting insulin analog and the other delivered a control phosphate buffered saline (PBS) solution with no insulin. While there was a small artifact in both conditions that increased for larger volumes, there was no difference between the artifacts in the sensing cannula delivering insulin compared with the sensing cannula delivering PBS as determined by integrating the area-under-the-curve of the sensor values following delivery of larger amounts of fluid (P = 0.7). The time for the sensor to recover from the artifact was found to be longer for larger fluid amounts compared with smaller fluid amounts (10.3 ± 8.5 min vs. 41.2 ± 78.3 s, P < 0.05). Using a smart-sampling Kalman filtering smoothing algorithm improved sensor accuracy. When using an all-point calibration on all sensors, the smart-sampling Kalman filter reduced the mean absolute relative difference from 10.9% to 9.5% and resulted in 96.7% of the data points falling within the A and B regions of the Clarke error grid. Despite a small artifact, which is likely due to dilution by fluid delivery, it is possible to continuously measure glucose in a cannula that simultaneously delivers insulin.
Collapse
|
21
|
Abstract
Treatment of type 1 diabetes with exogenous insulin often results in unpredictable daily glucose variability and hypoglycemia, which can be dangerous. Automated insulin delivery systems can improve glucose control while reducing burden for people with diabetes. One approach to improve treatment outcomes is to incorporate the counter-regulatory hormone glucagon into the automated delivery system to help prevent the hypoglycemia that can be induced by the slow pharmacodynamics of insulin action. This article explores the advantages and disadvantages of incorporating glucagon into dual-hormone automated hormone delivery systems.
Collapse
Affiliation(s)
- Leah M Wilson
- Division of Endocrinology, Diabetes and Clinical Nutrition, Oregon Health & Science University, Harold Schnitzer Diabetes Health Center, 3181 Southwest Sam Jackson Park Road, L607, Portland, OR 97239-3098, USA.
| | - Peter G Jacobs
- Department of Biomedical Engineering, Oregon Health & Science University, Mail Code: CH13B, 3303 Southwest Bond Avenue, Portland, OR 97239, USA
| | - Jessica R Castle
- Division of Endocrinology, Diabetes and Clinical Nutrition, Oregon Health & Science University, Harold Schnitzer Diabetes Health Center, 3181 Southwest Sam Jackson Park Road, L607, Portland, OR 97239-3098, USA
| |
Collapse
|
22
|
Toffanin C, Kozak M, Sumnik Z, Cobelli C, Petruzelkova L. In Silico Trials of an Open-Source Android-Based Artificial Pancreas: A New Paradigm to Test Safety and Efficacy of Do-It-Yourself Systems. Diabetes Technol Ther 2020; 22:112-120. [PMID: 31769699 DOI: 10.1089/dia.2019.0375] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Objective: Safety data on Do-It-Yourself Artificial Pancreas Systems are missing. The most widespread in Europe is the AndroidAPS implementation of the OpenAPS algorithm. We used the UVA/Padova Type 1 Diabetes Simulator to in silico test safety and efficacy of this algorithm in different scenarios. Methods: We tested five configurations of the AndroidAPS algorithm differing in aggressiveness and patient's interaction with the system. All configurations were tested with insulin sensitivity variation of ±30%. The most promising configurations were tested in real-life scenarios: over- and underestimated bolus by 50%, bolus delivered 15 min before meal, and late bolus delivered 15 min after meal. Continuous Glucose Monitoring (CGM) time in ranges (TIRs) metrics were used to assess the glycemic control. Results: In silico testing showed that open-source closed-loop system AndroidAPS works effectively and safely. The best results were reached if AndroidAPS algorithm worked with microboluses and when half of calculated bolus was issued (mean glycemia 131 mg/dL, SD 27 mg/dL, TIR 91%, time between 54 and 70 mg/dL <1%, and low blood glucose index even <1). The meal bolus over- and underestimation as well as late bolus did not affect the TIR and, importantly, the time between 54 and 70 mg/dL. Conclusion: In silico testing proved that AndroidAPS implementation of the OpenAPS algorithm is safe and effective, and it showed a great potential to be tested in prospective home setting study.
Collapse
Affiliation(s)
- Chiara Toffanin
- Department of Electrical, Computer and Biomedical Engineering, University of Pavia, Pavia, Italy
| | - Milos Kozak
- CLOSED LOOP Systems, Prague, Czech Republic, Prague, Czech Republic
| | - Zdenek Sumnik
- Department of Paediatrics, Motol University Hospital, 2nd Faculty of Medicine, Charles University, Prague, Czech Republic
| | - Claudio Cobelli
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Lenka Petruzelkova
- Department of Paediatrics, Motol University Hospital, 2nd Faculty of Medicine, Charles University, Prague, Czech Republic
| |
Collapse
|
23
|
Herrero P, El-Sharkawy M, Daniels J, Jugnee N, Uduku CN, Reddy M, Oliver N, Georgiou P. The Bio-inspired Artificial Pancreas for Type 1 Diabetes Control in the Home: System Architecture and Preliminary Results. J Diabetes Sci Technol 2019; 13:1017-1025. [PMID: 31608656 PMCID: PMC6835194 DOI: 10.1177/1932296819881456] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
BACKGROUND Artificial pancreas (AP) technology has been proven to improve glucose and patient-centered outcomes for people with type 1 diabetes (T1D). Several approaches to implement the AP have been described, clinically evaluated, and in one case, commercialized. However, none of these approaches has shown a clear superiority with respect to others. In addition, several challenges still need to be solved before achieving a fully automated AP that fulfills the users' expectations. We have introduced the Bio-inspired Artificial Pancreas (BiAP), a hybrid adaptive closed-loop control system based on beta-cell physiology and implemented directly in hardware to provide an embedded low-power solution in a dedicated handheld device. In coordination with the closed-loop controller, the BiAP system incorporates a novel adaptive bolus calculator which aims at improving postprandial glycemic control. This paper focuses on the latest developments of the BiAP system for its utilization in the home environment. METHODS The hardware and software architectures of the BiAP system designed to be used in the home environment are described. Then, the clinical trial design proposed to evaluate the BiAP system in an ambulatory setting is introduced. Finally, preliminary results corresponding to two participants enrolled in the trial are presented. RESULTS Apart from minor technical issues, mainly due to wireless communications between devices, the BiAP system performed well (~88% of the time in closed-loop) during the clinical trials conducted so far. Preliminary results show that the BiAP system might achieve comparable glycemic outcomes to the existing AP systems (~73% time in target range 70-180 mg/dL). CONCLUSION The BiAP system is a viable platform to conduct ambulatory clinical trials and a potential solution for people with T1D to control their glucose control in a home environment.
Collapse
Affiliation(s)
- Pau Herrero
- Centre for Bio-Inspired Technology, Department of Electrical and Electronic Engineering, Imperial College London, London, UK
| | - Mohamed El-Sharkawy
- Centre for Bio-Inspired Technology, Department of Electrical and Electronic Engineering, Imperial College London, London, UK
| | - John Daniels
- Centre for Bio-Inspired Technology, Department of Electrical and Electronic Engineering, Imperial College London, London, UK
| | - Narvada Jugnee
- Division of Diabetes, Endocrinology and Metabolism, Department of Medicine, Imperial College London, London, UK
| | - Chukwuma N. Uduku
- Division of Diabetes, Endocrinology and Metabolism, Department of Medicine, Imperial College London, London, UK
| | - Monika Reddy
- Division of Diabetes, Endocrinology and Metabolism, Department of Medicine, Imperial College London, London, UK
| | - Nick Oliver
- Division of Diabetes, Endocrinology and Metabolism, Department of Medicine, Imperial College London, London, UK
| | - Pantelis Georgiou
- Centre for Bio-Inspired Technology, Department of Electrical and Electronic Engineering, Imperial College London, London, UK
| |
Collapse
|
24
|
Moscardó V, Díez JL, Bondia J. Parallel Control of an Artificial Pancreas with Coordinated Insulin, Glucagon, and Rescue Carbohydrate Control Actions. J Diabetes Sci Technol 2019; 13:1026-1034. [PMID: 31631688 PMCID: PMC6835176 DOI: 10.1177/1932296819879093] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND An artificial pancreas with insulin and glucagon delivery has the potential to reduce the risk of hypo- and hyperglycemia in people with type 1 diabetes. However, a maximum dose of glucagon of 1 mg/d is recommended, potentially still requiring rescue carbohydrates in some situations. This work presents a parallel control structure with intrinsic insulin, glucagon, and rescue carbohydrates coordination to overcome glucagon limitations when needed. METHODS The coordinated controller that combines insulin, glucagon, and rescue carbohydrate suggestions (DH-CC-CHO) was compared with the insulin and glucagon delivery coordinated controller (DH-CC). The impact of carbohydrate quantization for practical delivery was also assessed. An in silico study using the UVA-Padova simulator, extended to include exercise and various sources of variability, was performed. RESULTS DH-CC and DH-CC-CHO performed similarly with regard to mean glucose (126.25 [123.43; 130.73] vs 127.92 [123.99; 132.97] mg/dL, P = .088), time in range (93.04 [90.00; 95.92] vs 92.91 [90.05; 95.75]%, P = .508), time above 180 mg/dL (4.94 [2.72; 7.53] vs 4.99 [2.93; 7.24]%, P = .966), time below 70 mg/dL (0.61 [0.09; 1.75] vs 0.96 [0.23; 2.17]%, P = .1364), insulin delivery (43.50 [38.68; 51.75] vs 42.86 [38.58; 51.36] U/d, P = .383), and glucagon delivery (0.75 [0.40; 1.83] vs 0.76 [0.43; 0.99] mg/d, P = .407). Time below 54 mg/dL was different (0.00 [0.00; 0.05] vs 0.00 [0.00; 0.16]%, P = .036), although non-clinically significant. This was due to the carbs quantization effect in a specific patient, as no statistical difference was found when carbs were not quantized (0.00 [0.00; 0.05] vs 0.00 [0.00; 0.00]%, P = .265). CONCLUSIONS The new strategy of automatic rescue carbohydrates suggestion in coordination with insulin and glucagon delivery to overcome constraints on daily glucagon delivery was successfully evaluated in an in silico proof of concept.
Collapse
Affiliation(s)
- Vanessa Moscardó
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, Valencia, Spain
| | - José Luis Díez
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, Valencia, Spain
- Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Av. Monforte de Lemos, Madrid, Spain
| | - Jorge Bondia
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, Valencia, Spain
- Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Av. Monforte de Lemos, Madrid, Spain
- Jorge Bondia, Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, C/Camino de Vera, s/n, 46022 Valencia, Spain.
| |
Collapse
|
25
|
Evans M, Wilkinson M, Giannpolou A. Fast-Acting Insulin Aspart: The Rationale for a New Mealtime Insulin. Diabetes Ther 2019; 10:1793-1800. [PMID: 31485918 PMCID: PMC6778592 DOI: 10.1007/s13300-019-00685-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Indexed: 12/31/2022] Open
Abstract
Attenuating postprandial hyperglycaemia is a critical factor in the achievement of optimal glucose control. Prandial insulin analogues have been developed to replicate the physiology of normal endogenous insulin secretion and action, with the aim of limiting postprandial glucose excursions. There is still, however, a significant unmet need, with many people failing to achieve desired glycaemic control targets despite the current armamentarium of prandial insulin analogues. Such insulins have a delayed onset and a longer duration of action than endogenous insulin production. There has been considerable focus on attempts to accelerate the time-action profile of prandial exogenous insulin in order to produce a more physiological profile. One such approach is to modify the insulin formulation. Fast-acting insulin aspart is a modified formulation of insulin aspart containing niacinamide and L-arginine. It has an earlier onset of action than aspart. In an extensive trial programme, this faster aspart demonstrated similar HbA1c reductions to those achieved with aspart but superior postprandial glucose reductions, with no increase in hypoglycaemia. Furthermore, administration of faster aspart up to 20 min after the start of a meal permitted similar glucose control to aspart given preprandially. These data, taken in totality, illustrate the potential role of faster insulin aspart in clinical practice.
Collapse
Affiliation(s)
- Marc Evans
- Department of Diabetes and Endocrinology, University Hospital Llandough, Penlan Road, Penarth, CF64 4XX, UK.
| | - Mathew Wilkinson
- Department of Diabetes and Endocrinology, University Hospital Llandough, Penlan Road, Penarth, CF64 4XX, UK
| | - Angeliki Giannpolou
- Department of Diabetes and Endocrinology, University Hospital Llandough, Penlan Road, Penarth, CF64 4XX, UK
| |
Collapse
|
26
|
Fast-Acting Insulin Aspart and the Need for New Mealtime Insulin Analogues in Adults With Type 1 and Type 2 Diabetes: A Canadian Perspective. Can J Diabetes 2019; 43:515-523. [DOI: 10.1016/j.jcjd.2019.01.004] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Revised: 12/06/2018] [Accepted: 01/16/2019] [Indexed: 12/12/2022]
|
27
|
Cappon G, Vettoretti M, Sparacino G, Facchinetti A. Continuous Glucose Monitoring Sensors for Diabetes Management: A Review of Technologies and Applications. Diabetes Metab J 2019; 43:383-397. [PMID: 31441246 PMCID: PMC6712232 DOI: 10.4093/dmj.2019.0121] [Citation(s) in RCA: 157] [Impact Index Per Article: 31.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Accepted: 07/10/2019] [Indexed: 01/21/2023] Open
Abstract
By providing blood glucose (BG) concentration measurements in an almost continuous-time fashion for several consecutive days, wearable minimally-invasive continuous glucose monitoring (CGM) sensors are revolutionizing diabetes management, and are becoming an increasingly adopted technology especially for diabetic individuals requiring insulin administrations. Indeed, by providing glucose real-time insights of BG dynamics and trend, and being equipped with visual and acoustic alarms for hypo- and hyperglycemia, CGM devices have been proved to improve safety and effectiveness of diabetes therapy, reduce hypoglycemia incidence and duration, and decrease glycemic variability. Furthermore, the real-time availability of BG values has been stimulating the realization of new tools to provide patients with decision support to improve insulin dosage tuning and infusion. The aim of this paper is to offer an overview of current literature and future possible developments regarding CGM technologies and applications. In particular, first, we outline the technological evolution of CGM devices through the last 20 years. Then, we discuss about the current use of CGM sensors from patients affected by diabetes, and, we report some works proving the beneficial impact provided by the adoption of CGM. Finally, we review some recent advanced applications for diabetes treatment based on CGM sensors.
Collapse
Affiliation(s)
- Giacomo Cappon
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Martina Vettoretti
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Giovanni Sparacino
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Andrea Facchinetti
- Department of Information Engineering, University of Padova, Padova, Italy.
| |
Collapse
|
28
|
Beato-Víbora PI, Arroyo-Díez FJ. New uses and formulations of glucagon for hypoglycaemia. Drugs Context 2019; 8:212599. [PMID: 31402931 PMCID: PMC6675539 DOI: 10.7573/dic.212599] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Revised: 06/23/2019] [Accepted: 06/26/2019] [Indexed: 12/11/2022] Open
Abstract
Hypoglycaemia is the more frequent complication of insulin therapy and the main barrier to tight glycaemic control. Injectable glucagon and oral intake of carbohydrates are the recommended treatments for severe and non-severe hypoglycaemia episodes, respectively. Nasal glucagon is currently being developed as a ready-to-use device, to simplify severe hypoglycaemia rescue. Stable forms of liquid glucagon could open the field for different approaches for mild to moderate hypoglycaemia treatment, such as mini-doses of glucagon or continuous subcutaneous glucagon infusion as a part of dual-hormone closed-loop systems. Pharmaceutical companies are developing stable forms of native glucagon or glucagon analogues for that purpose.
Collapse
Affiliation(s)
- Pilar I Beato-Víbora
- Department of Endocrinology and Nutrition, Department of Paediatrics, Badajoz University Hospital, Badajoz, Spain
| | - Francisco J Arroyo-Díez
- Department of Endocrinology and Nutrition, Department of Paediatrics, Badajoz University Hospital, Badajoz, Spain
| |
Collapse
|
29
|
Kovatchev B. A Century of Diabetes Technology: Signals, Models, and Artificial Pancreas Control. Trends Endocrinol Metab 2019; 30:432-444. [PMID: 31151733 DOI: 10.1016/j.tem.2019.04.008] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2019] [Revised: 04/14/2019] [Accepted: 04/25/2019] [Indexed: 12/24/2022]
Abstract
Arguably, diabetes mellitus is one of the best-quantified human conditions: elaborate in silico models describe the action of the human metabolic system; real-time signals such as continuous glucose monitoring are readily available; insulin delivery is being automated; and control algorithms are capable of optimizing blood glucose fluctuation in patients' natural environments. The transition of the artificial pancreas (AP) to everyday clinical use is happening now, and is contingent upon seamless concerted work of devices encompassing the patient in a digital treatment ecosystem. This review recounts briefly the story of diabetes technology, which began a century ago with the discovery of insulin, progressed through glucose monitoring and subcutaneous insulin delivery, and is now rapidly advancing towards fully automated clinically viable AP systems.
Collapse
Affiliation(s)
- Boris Kovatchev
- University of Virginia School of Medicine, UVA Center for Diabetes Technology, Ivy Translational Research Building, 560 Ray C. Hunt Drive, Charlottesville, VA 22903-2981, USA.
| |
Collapse
|
30
|
Hövelmann U, Olsen MB, Mouritzen U, Lamers D, Kronshage B, Heise T. Low doses of dasiglucagon consistently increase plasma glucose levels from hypoglycaemia and euglycaemia in people with type 1 diabetes mellitus. Diabetes Obes Metab 2019; 21:601-610. [PMID: 30350477 PMCID: PMC6587565 DOI: 10.1111/dom.13562] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Revised: 10/07/2018] [Accepted: 10/16/2018] [Indexed: 02/06/2023]
Abstract
AIM To characterize the pharmacokinetic and pharmacodynamic properties of dasiglucagon, a novel, stable and liquid formulated glucagon analogue, during hypoglycaemic and euglycaemic conditions in adult patients with type 1 diabetes mellitus. RESEARCH DESIGN AND METHODS In this randomized double-blind trial, 17 patients received four single subcutaneous doses (0.03, 0.08, 0.2 and 0.6 mg) of dasiglucagon (4 mg/mL formulation) under euglycaemic (plasma glucose [PG] 5.6 mmol/L [100 mg/dL]) or hypoglycaemic (PG 3.1-3.7 mmol/L [56-66 mg/dL]) conditions. For comparison, three doses (0.03, 0.08 and 0.2 mg) of a commercial glucagon formulation (Eli Lilly) were investigated at euglycaemia. RESULTS Dasiglucagon led to a dose-dependent and rapid increase in PG levels across all doses tested (mean increases 30 minutes post-dosing of 2.2 to 4.4 mmol/L [39-80 mg/dL] from euglycaemia and 1.3 to 5.2 mmol/L [24-94 mg/dL] from hypoglycaemia), which was higher than the rises elicited by similar doses of commercial glucagon (1.7-3.9 mmol/L [30-71 mg/dL]). The median time (range) to an increase in PG of >1.1 mmol/L (20 mg/dL) was <20 (18-19.5) minutes with 0.03 mg dasiglucagon and, with higher doses, the median times ranged from 9 to 15 minutes (commercial glucagon 13-14 minutes). In hypoglycaemia, 0.03 and 0.08 mg dasiglucagon re-established normoglycaemia (PG ≥3.9 mmol/L [70 mg/dL]) within median times of 14 and 10 minutes, respectively. Nausea and vomiting occurred more frequently with dasiglucagon than with commercial glucagon at identical doses which might be attributable to dasiglucagon's higher potency. CONCLUSION Dasiglucagon rapidly increased PG at doses of 0.03 to 0.6 mg in a dose-dependent manner and, therefore, is a good candidate for use in dual-hormone artificial pancreas systems.
Collapse
|
31
|
Affiliation(s)
- Piotr Foltynski
- Nalecz Institute of Biocybernetics and Biomedical Engineering, PAS - Department of Modeling and Supporting of Internal Organs Functions; Warsaw Poland
| |
Collapse
|
32
|
Dadlani V, Pinsker JE, Dassau E, Kudva YC. Advances in Closed-Loop Insulin Delivery Systems in Patients with Type 1 Diabetes. Curr Diab Rep 2018; 18:88. [PMID: 30159816 DOI: 10.1007/s11892-018-1051-z] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
To provide a current review of closed-loop insulin delivery or artificial pancreas (AP) as therapy for people with type 1 diabetes mellitus (T1D) RECENT FINDINGS: The Medtronic Minimed 670G AP system has been in use in clinical practice since March 2017. Currently, Medtronic is conducting a large randomized clinical trial to evaluate its efficacy further in T1D. Simultaneously, the NIH has funded four research consortia to accelerate progress to approval of other AP and decision support systems. Several research groups are currently developing next-generation AP systems, with a number of companies moving toward releasing closed-loop systems in the future. AP systems are also being tested in select populations such as hypoglycemia-unaware T1D and pregnant T1D. AP research is rapidly advancing. The clinical range of AP will be expanded in the next decade.
Collapse
Affiliation(s)
- Vikash Dadlani
- Endocrine Research Unit, Mayo Clinic, 200 First Street SW, Rochester, MN, 55902, USA
| | - Jordan E Pinsker
- Sansum Diabetes Research Institute, 2219 Bath Street, Santa Barbara, CA, 93105, USA
| | - Eyal Dassau
- Sansum Diabetes Research Institute, 2219 Bath Street, Santa Barbara, CA, 93105, USA
- Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, 29 Oxford St, Cambridge, MA, USA
- Joslin Diabetes Center, Boston, MA, USA
| | - Yogish C Kudva
- Endocrine Research Unit, Mayo Clinic, 200 First Street SW, Rochester, MN, 55902, USA.
| |
Collapse
|
33
|
Majeed W, Thabit H. Closed-loop insulin delivery: current status of diabetes technologies and future prospects. Expert Rev Med Devices 2018; 15:579-590. [PMID: 30027775 DOI: 10.1080/17434440.2018.1503530] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
INTRODUCTION Type 1 diabetes is characterised by destruction of pancreatic beta cells, leading to insulin deficiency and hyperglycaemia. The mainstay of treatment remains lifelong insulin therapy as a sustainable cure has as yet proven elusive. The burden of daily management of type 1 diabetes has contributed to suboptimal outcomes for people living with the condition. Innovative technological approaches have been shown to improve glycaemic and patient-related outcomes. AREAS COVERED We discuss recent advances in technologies in type 1 diabetes including closed-loop systems, also known as the 'artificial pancreas. Its various components, technical aspects and limitations are reviewed. We also discuss its advent into clinical practice, and other systems in development. Evidence from clinical studies are summarised. EXPERT COMMENTARY The recent approval of a hybrid closed-loop system for clinical use highlights the significant progress made in this field. Results from clinical studies have shown safety and glycaemic benefit, however challenges remain around improving performance and acceptability. More data is required to establish long-term clinical efficacy and cost-effectiveness, to fulfil the expectations of people with type 1 diabetes.
Collapse
Affiliation(s)
- Waseem Majeed
- a Manchester Academic Health Science Centre , Manchester University Hospitals NHS Foundation Trust , Manchester , UK
| | - Hood Thabit
- a Manchester Academic Health Science Centre , Manchester University Hospitals NHS Foundation Trust , Manchester , UK.,b Division of Diabetes, Endocrinology and Gastroenterology, Faculty of Biology, Medicine and Health , University of Manchester , Manchester , UK
| |
Collapse
|
34
|
Affiliation(s)
- H R Murphy
- UK and Republic of Ireland Regional Editor, Diabetic Medicine, London, UK
- Department of Women's and Children's Health, Kings College, London, UK
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - R I G Holt
- Editor-in-Chief, Diabetic Medicine, Southampton, UK
- University of Southampton, Southampton, UK
| |
Collapse
|