Momeniha F, Jafari AJ, Faridi S, Rafiee A, Oskouie AA. Effects of exposure to trihalomethanes in swimming pool waters on metabolomics profile: a randomized parallel design trial. JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE & ENGINEERING 2024; 22:533-544. [PMID: 39464829 PMCID: PMC11499471 DOI: 10.1007/s40201-024-00912-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 06/23/2024] [Indexed: 10/29/2024]
Abstract
Biological mechanisms of exposure to Trihalomethanes (THMs) in swimming pools remain unclear. Investigation of short-term changes in metabolomic profiles due to exposure to THMs during swimming can help to understand the health effects-related mechanisms. With this in view, we aimed to assess exposure of swimmers to THMs in chlorine and ozone-chlorine swimming pools using the metabolomics approach from September 2020 to January 2021 in Tehran. Two parallel panels of 29 healthy adult subjects swam over 60 min in either of swimming pools. Blood samples were collected before and 2 h after swimming to assess metabolomic profile using Hydrogen-Nuclear Magnetic Resonance Spectroscopy (H-NMR). Differential metabolites between the two groups were identified by multivariate analysis methods such as Orthogonal Partial Least-Squares Discriminant Analysis (OPLS-DA) and Random Forest (RF). The levels of THMs in exhaled air as a biomarker of exposure and the metabolic profile as a biomarker of the effect changed significantly between two participants of swimming pools. Based on the significant metabolites, the biochemical pathways were identified by the method of Metabolite Setts Enrichment Analysis (MSEA) and by using the Metaboanalyst platform. The pathways of tryptophan metabolism, galactose metabolism and fructose and mannose metabolism were the most important biochemically significant pathways in individuals after exposure to THMs. Finally, findings from metabolic changes in our study indicate that exposure to THMs in swimming pools can activate the mechanisms of central nervous system disorders, increased uric acid, increased risk of bladder cancer and oxidative stress. Supplementary Information The online version contains supplementary material available at 10.1007/s40201-024-00912-2.
Collapse
Affiliation(s)
- Fatemeh Momeniha
- Center for Solid Waste Research (CSWR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
- Department of Environmental Health Engineering, School of Public Health, Iran University of Medical Sciences, Tehran, Iran
| | - Ahmad Jonidi Jafari
- Department of Environmental Health Engineering, School of Public Health, Iran University of Medical Sciences, Tehran, Iran
| | - Sasan Faridi
- Center for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
- Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
| | - Ata Rafiee
- Department of Medicine, University of Alberta, Edmonton, AB Canada
| | - Afsaneh Arefi Oskouie
- Department of Basic Sciences, Faculty of Paramedical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
2
|
Bougault V, Valorso R, Sarda-Esteve R, Baisnee D, Visez N, Oliver G, Bureau J, Abdoussi F, Ghersi V, Foret G. Paris air quality monitoring for the 2024 Olympics and Paralympics: focus on air pollutants and pollen. Br J Sports Med 2024; 58:973-982. [PMID: 39054048 PMCID: PMC11420723 DOI: 10.1136/bjsports-2024-108129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/06/2024] [Indexed: 07/27/2024]
Abstract
BACKGROUND Exposure to air pollution can affect the health of individuals with respiratory disease, but may also impede the health and performance of athletes. This is potentially relevant for people travelling to and competing in the Olympic and Paralympic Games (OPG) in Paris. We describe anticipated air quality in Paris based on historical monitoring data and describe the impact of the process on the development of monitoring strategies for future international sporting events. METHODS Air pollutant data for July to September 2020-2023 and pollen data for 2015-2022 were provided by Airparif (particulate matter (PM2.5), nitrogen dioxide (NO2) and ozone (O3)) and RNSA stations in the Paris region. Airparif's street-level numerical modelling provided spatial data for the OPG venues. RESULTS The maximum daily mean PM2.5 was 11±6 µg/m3 at traffic stations, below the WHO recommended daily air quality threshold (AQT). Daily NO2 concentrations ranged from 5±3 µg/m3 in rural areas to 17±14 µgm3 in urban areas. Near traffic stations, this rose to 40±24 µg/m3 exceeding the WHO AQT. Both peaked around 06:00 and 20:00 UTC (coordinated universal time). The ambient O3 level exceeded the AQT on 20 days per month and peaked at 14:00 UTC. The main allergenic taxa from June to September was Poaceae (ie, grass pollen variety). CONCLUSION Air pollutant levels are expected to be within accepted air quality thresholds at the Paris OPG. However, O3 concentrations may be significantly raised in very hot and clear conditions and grass pollen levels will be high, prompting a need to consider and manage this risk in susceptible individuals.
Collapse
Affiliation(s)
| | - Richard Valorso
- Univ Paris Est Creteil and Université Paris Cité, CNRS, LISA, F-94010, Créteil, France
| | - Roland Sarda-Esteve
- CEA Orme des merisiers, UMR 8212, Laboratoire des Sciences du Climat et de l'Environnement, Saint-Aubin, France
| | - Dominique Baisnee
- CEA Orme des merisiers, UMR 8212, Laboratoire des Sciences du Climat et de l'Environnement, Saint-Aubin, France
| | - Nicolas Visez
- CNRS, UMR, 8516, LASIRE - Laboratoire de Spectroscopie pour les Interactions, la Réactivité et l'Environnement, Université de Lille, Lille, France
- RNSA, Réseau National de Surveillance Aérobiologique, Brussieu, France
| | - Gilles Oliver
- RNSA, Réseau National de Surveillance Aérobiologique, Brussieu, France
| | | | | | | | - Gilles Foret
- Univ Paris Est Creteil and Université Paris Cité, CNRS, LISA, F-94010, Créteil, France
| |
Collapse
|
3
|
Meng R, Li H, Zhang Z, Dong C. Model-based prototype design, establishment and operation of ventilation system for underground gymnasium. Heliyon 2024; 10:e36055. [PMID: 39224320 PMCID: PMC11367119 DOI: 10.1016/j.heliyon.2024.e36055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 07/22/2024] [Accepted: 08/08/2024] [Indexed: 09/04/2024] Open
Abstract
Underground small indoor gymnasiums (USIG) are important public places, it is vital to design and build a very economical and efficient ventilation system for effective closed-loop regulation of temperature and gases concentration at prescribed levels. In the article, the model-based prototype design, establishment and operation were proposed and applied to closed-loop control system of the underground small indoor gymnasiums' ventilation system (USIGVS). First of all, the extended Multiphysics model was developed through feedback connecting the 3D Multiphysics model of air flow rate, temperature, O2 and CO2 concentration with a 0D proportional-integral-derivative (PID) controller via Neumann boundary condition, hence a close-loop USIGVS was constructed for feedback control of temperature and gases concentration in ping-pong USIG. Simultaneously, a cost function sufficiently representing the design requirement was formulated. Then global parameter sensitivity analysis (GPSA) was applied for sensitivity ranking of parameters including geometric parameters of USIGVS and tunable parameters of PID controller. The GPSA proved that sensitivity ordering of the cost function to each parameter was proportional gain (k p ) > derivative gain (k d ) > distance from left inlet to bottom (r) > distance from outlet pipe to bottom (d) > integrative gain (k i ) > distance from upper inlet pipe to left (h), respectively, and the k p , k d and r was the parameter influencing the cost function the most. The optimal parameters determined by both GPSA and response optimization were k p = 3.17 m4 mol-1 s-1, k d = 1.49 m4 mol-1, r = 2.04 m, d = 3.12 m, k i = 0.37 m4 mol-1 s-2 and h = 3.85 m. Finally, the closed-loop USIGVS prototype with optimal parameters was designed and established through real-time simulation. The real-time operation confirmed that the temperature and gases concentrations were robust maintained at prescribed levels with desired dynamic response characteristics and lower power consumption, and the expected requirements were achieved for the design, establishment and operation of closed-loop USIGVS control system prototype.
Collapse
Affiliation(s)
- Ran Meng
- Laboratory of Virtual Reality and Simulation Technology, Shandong Sport University, Jinan, 250102, China
| | - Hui Li
- Shandong Water conservancy vocational college, Rizhao, 276826, China
| | - Zhiyong Zhang
- Laboratory of Virtual Reality and Simulation Technology, Shandong Sport University, Jinan, 250102, China
| | - Chen Dong
- Laboratory of Virtual Reality and Simulation Technology, Shandong Sport University, Jinan, 250102, China
- Krirk University, Bangkok, 10220, Thailand
| |
Collapse
|
4
|
Zhang Y, Qian Y, Wen Y, Gui Q, Xu Y, Lu X, Zhang L, Song W. In Situ Preparation of Chlorine-Regenerable Antimicrobial Polymer Molecular Sieve Membranes. Molecules 2024; 29:2980. [PMID: 38998932 PMCID: PMC11243515 DOI: 10.3390/molecules29132980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Revised: 06/11/2024] [Accepted: 06/20/2024] [Indexed: 07/14/2024] Open
Abstract
Microbial contamination has profoundly impacted human health, and the effective eradication of widespread microbial issues is essential for addressing serious hygiene concerns. Taking polystyrene (PS) membrane as an example, we herein developed report a robust strategy for the in situ preparation of chlorine-regenerable antimicrobial polymer molecular sieve membranes through combining post-crosslinking and nucleophilic substitution reaction. The cross-linking PS membranes underwent a reaction with 5,5-dimethylhydantoin (DMH), leading to the formation of polymeric N-halamine precursors (PS-DMH). These hydantoinyl groups within PS-DMH were then efficiently converted into biocidal N-halamine structures (PS-DMH-Cl) via a simple chlorination process. ATR-FTIR and XPS spectra were recorded to confirm the chemical composition of the as-prepared PS-DMH-Cl membranes. SEM analyses revealed that the chlorinated PS-DMH-Cl membranes displayed a rough surface with a multitude of humps. The effect of chlorination temperature and time on the oxidative chlorine content in the PS-DMH-Cl membranes was systematically studied. The antimicrobial assays demonstrated that the PS-DMH-Cl membranes could achieve a 6-log inactivation of E. coli and S. aureus within just 4 min of contact time. Additionally, the resulting PS-DMH-Cl membranes exhibited excellent stability and regenerability of the oxidative chlorine content.
Collapse
Affiliation(s)
- Yu Zhang
- Shanghai Key Laboratory of Molecular Imaging, School of Pharmacy, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
- State Key Laboratory of Molecular Engineering of Polymers, Fudan University, Shanghai 200433, China
| | - Yiduo Qian
- Shanghai Key Laboratory of Molecular Imaging, School of Pharmacy, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
| | - Yuheng Wen
- School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Qiudi Gui
- Shanghai Key Laboratory of Molecular Imaging, School of Pharmacy, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
| | - Yixin Xu
- Shanghai Key Laboratory of Molecular Imaging, School of Pharmacy, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
| | - Xiuhong Lu
- Shanghai Key Laboratory of Molecular Imaging, School of Pharmacy, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
| | - Li Zhang
- Shanghai Key Laboratory of Molecular Imaging, School of Pharmacy, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
| | - Wenliang Song
- School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai 200093, China
| |
Collapse
|
5
|
Peixoto C, Pereira MDC, Morais S, Slezakova K. Assessment of indoor air quality in health clubs: insights into (ultra)fine and coarse particles and gaseous pollutants. Front Public Health 2023; 11:1310215. [PMID: 38089025 PMCID: PMC10715262 DOI: 10.3389/fpubh.2023.1310215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 11/10/2023] [Indexed: 12/18/2023] Open
Abstract
Introduction Exercising on regular basis provides countless health benefits. To ensure the health, well-being and performance of athletes, optimal indoor air quality, regular maintenance and ventilation in sport facilities are essential. Methods This study assessed the levels of particulate, down to the ultrafine range (PM10, PM2.5, and particle number concentration in size range of 20-1,000 nm, i.e., - PNC20-1000 nm), gaseous pollutants (total volatile organic compounds - TVOCs, CO2, and O3) and comfort parameters (temperature - T, relative humidity - RH) in different functional spaces of health clubs (n = 8), under specific occupancy and ventilation restrictions. Results and Discussion In all HCs human occupancy resulted in elevated particles (up to 2-3 times than those previously reported), considering mass concentrations (PM10: 1.9-988.5 μg/m3 PM2.5: 1.6-479.3 μg/m3) and number (PNC 1.23 × 103 - 9.14 × 104 #/cm3). Coarse and fine PM indicated a common origin (rs = 0.888-0.909), while PNC showed low-moderate associations with particle mass (rs = 0.264-0.629). In addition, up to twice-higher PM and PNC were detected in cardiofitness & bodybuilding (C&B) areas as these spaces were the most frequented, reinforcing the impacts of occupational activities. In all HCs, TVOCs (0.01-39.67 mg/m3) highly exceeded the existent protection thresholds (1.6-8.9 times) due to the frequent use of cleaning products and disinfectants (2-28 times higher than in previous works). On contrary to PM and PNC, TVOCs were higher (1.1-4.2 times) in studios than in C&B areas, due to the limited ventilations combined with the smaller room areas/volumes. The occupancy restrictions also led to reduced CO2 (122-6,914 mg/m3) than previously observed, with the lowest values in HCs with natural airing. Finally, the specific recommendations for RH and T in sport facilities were largely unmet thus emphasizing the need of proper ventilation procedures in these spaces.
Collapse
Affiliation(s)
- Cátia Peixoto
- REQUIMTE–LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida, Porto, Portugal
- LEPABE-ALiCE, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, Porto, Portugal
| | - Maria do Carmo Pereira
- LEPABE-ALiCE, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, Porto, Portugal
| | - Simone Morais
- REQUIMTE–LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida, Porto, Portugal
| | - Klara Slezakova
- LEPABE-ALiCE, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, Porto, Portugal
| |
Collapse
|
6
|
Li Z, Ding Y, Wang D, Kang N, Tao Y, Zhao X, Zhang B, Zhang Z. Understanding the time-activity pattern to improve the measurement of personal exposure: An exploratory and experimental research. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2023; 334:122131. [PMID: 37429486 DOI: 10.1016/j.envpol.2023.122131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 06/28/2023] [Accepted: 06/29/2023] [Indexed: 07/12/2023]
Abstract
Although ambient fine particulate matter (PM2.5) concentrations and their components are commonly used as proxies for personal exposure monitoring, developing an accurate and cost-effective method to use these proxies for personal exposure measurement continues to pose a significant challenge. Herein, we propose a scenario-based exposure model to precisely estimate personal exposure level of heavy metal(loid)s (HMs) using scenario HMs concentrations and time-activity patterns. Personal exposure levels and ambient pollution levels for PM2.5 and HMs differed significantly with corresponding personal/ambient ratios of approximately 2, and exposure scenarios could narrow the assessment error gap by 26.1-45.4%. Using a scenario-based exposure model, we assessed the associated health risks of a large sample population and identified that the carcinogenic risk of As exceeded 1 × 10-6, while we observed non-carcinogenic risks from As, Cd, Ni, and Mn in personal exposure to PM2.5. We conclude that the scenario-based exposure model is a preferential alternative for monitoring personal exposure compared to ambient concentrations. This method ensures the feasibility of personal exposure monitoring and health risk assessments in large-scale studies.
Collapse
Affiliation(s)
- Zhenglei Li
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China; Key Laboratory for Environmental Pollution Prediction and Control, Gansu Province, College of Earth and Environmental Sciences, Lanzhou University, Lanzhou, 730000, China
| | - Yan Ding
- Vehicle Emission Control Center of Ministry of Ecology and Environment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China
| | - Danlu Wang
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China
| | - Ning Kang
- Key Laboratory for Environmental Pollution Prediction and Control, Gansu Province, College of Earth and Environmental Sciences, Lanzhou University, Lanzhou, 730000, China
| | - Yan Tao
- Key Laboratory for Environmental Pollution Prediction and Control, Gansu Province, College of Earth and Environmental Sciences, Lanzhou University, Lanzhou, 730000, China
| | - Xiuge Zhao
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China.
| | - Bin Zhang
- Tianjin Binhai New Area Eco-environmental Monitoring Center, Tianjin, 300457, China
| | - Zuming Zhang
- Tianjin Binhai New Area Eco-environmental Monitoring Center, Tianjin, 300457, China
| |
Collapse
|
7
|
Liu C, Hou HS. Physical exercise and persistent organic pollutants. Heliyon 2023; 9:e19661. [PMID: 37809764 PMCID: PMC10558913 DOI: 10.1016/j.heliyon.2023.e19661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 08/29/2023] [Accepted: 08/29/2023] [Indexed: 10/10/2023] Open
Abstract
Exposure to the legacy and emerging persistent organic pollutants (POPs) incessantly has become an important threat to individual health, which is closely related to neurodevelopment, endocrine and cardiovascular homeostasis. Exercise, on the other hand, has been consistently shown to improve physical fitness. Whereas associations between traditional air pollutants, exercise and lung function have been thoroughly reviewed, reviews on associations between persistent organic pollutants and exercise are scarce. Hence, a literature review focused on exercise, exposure to POPs, and health risk assessment was performed for studies published from 2004 to 2022. The purpose of this review is to provide an overview of exposure pathways and levels of POPs during exercise, as well as the impact of exercise on health concerns attributable to the redistribution, metabolism, and excretion of POPs in vivo. Therein lies a broader array of exercise benefits, including insulin sensitizing, mitochondrial DNA repair, lipid metabolism and intestinal microecological balance. Physical exercise is conducive to reduce POPs body burden and resistant to health hazards of POPs generally. Besides, individual lipid metabolism condition is a critical factor in evaluating potential link in exercise, POPs and health effects.
Collapse
Affiliation(s)
- Chang Liu
- College of P.E, Minzu University of China, # 27, South Street Zhongguancun, Beijing, 100081, China
| | - Hui sheng Hou
- College of P.E, Minzu University of China, # 27, South Street Zhongguancun, Beijing, 100081, China
| |
Collapse
|
8
|
Wang C, Liggio J, Wentzell JJB, Jorga S, Folkerson A, Abbatt JPD. Chloramines as an important photochemical source of chlorine atoms in the urban atmosphere. Proc Natl Acad Sci U S A 2023; 120:e2220889120. [PMID: 37459517 PMCID: PMC10372683 DOI: 10.1073/pnas.2220889120] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Accepted: 06/10/2023] [Indexed: 07/29/2023] Open
Abstract
Monochloramine, dichloramine and trichloramine (NH2Cl, NHCl2, NCl3) are measured in the ambient atmosphere, in downtown Toronto in summer (median 39, 15 and 2.8 ppt) and winter (median 11, 7.3 and 0.7 ppt). NCl3 and NHCl2 were also measured in summer (median 1.3 and 14 ppt) from a suburban Toronto location. Measurements at two locations demonstrate prevalence of chloramines in an urban atmosphere. At both sites, NCl3 exhibits a strong diel pattern with maximum values during the night, and photolytic loss with sunrise. At the downtown site, a strong positive correlation between NH2Cl and NHCl2 in the summer night indicates a common source, with daily average peak mixing ratios approaching 500 and 250 ppt, respectively. As a previously unidentified source of chlorine (Cl) atoms, we demonstrate that NCl3 photolysis contributes 49 to 82% of the total local summertime Cl production rate at different times during the day with an average noontime peak of 3.8 × 105 atoms/cm3/s, with smaller contributions from ClNO2 and Cl2. Photolysis of NH2Cl and NHCl2 may augment this Cl production rate. Our measurements also demonstrate a daytime enhancement of chloroacetone in both the summer and winter, demonstrating the importance of Cl photochemistry. The results suggest that chloramines are an important source of Cl atoms in urban areas, with potential impacts on the abundance of organic compounds, ozone, nitrogen oxides, and particulate matter. Future studies should explore the vertical gradients of chloramines and their contribution to Cl production throughout the boundary layer.
Collapse
Affiliation(s)
- Chen Wang
- Guangdong Provincial Observation and Research Station for Coastal Atmosphere and Climate of the Greater Bay Area, School of Environmental Science and Engineering, Southern University of Science and Technology, Shenzhen518055, China
- Department of Chemistry, University of Toronto, Toronto, ONM5S 3H6, Canada
- Shenzhen Key Laboratory of Precision Measurement and Early Warning Technology for Urban Environmental Health Risks, School of Environmental Science and Engineering, Southern University of Science and Technology, Shenzhen518055, China
| | - John Liggio
- Air Quality Research Division, Environment and Climate Change Canada, Toronto, ONM3H 5T4, Canada
| | - Jeremy J. B. Wentzell
- Air Quality Research Division, Environment and Climate Change Canada, Toronto, ONM3H 5T4, Canada
| | - Spiro Jorga
- Department of Chemistry, University of Toronto, Toronto, ONM5S 3H6, Canada
| | - Andrew Folkerson
- Department of Chemistry, University of Toronto, Toronto, ONM5S 3H6, Canada
| | | |
Collapse
|
9
|
Zhang D, Ortiz MA, Bluyssen PM. A review on indoor environmental quality in sports facilities: Indoor air quality and ventilation during a pandemic. INDOOR + BUILT ENVIRONMENT : THE JOURNAL OF THE INTERNATIONAL SOCIETY OF THE BUILT ENVIRONMENT 2023; 32:831-851. [PMID: 38603231 PMCID: PMC9790860 DOI: 10.1177/1420326x221145862] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2023]
Abstract
Because of COVID-19, the indoor environmental quality (IEQ) in sports facilities has been a concern to environmental health practitioners. To develop an overall understanding of the available guidelines and standards and studies performed on IEQ in sports facilities, an extensive literature study was conducted, with the aim of identifying: (1) indicators that are being used to assess IEQ in different sports facilities; (2) indicators that are potentially interesting to be used to assess indoor air, in particular; (3) gaps in knowledge to determine whether sports facilities are safe, healthy and comfortable for people to stay and perform their activities. The outcome indicates that most current standards and previous investigations on IEQ in sports facilities mainly focused on dose-related indicators (such as ventilation rate), while building-related indicators (such as ventilation regime) and occupant-related indicators (such as IEQ preferences) were rarely considered. Little attention is given to the fact that ventilation systems may play an important role in the air quality of the location, and few investigations have been performed on the transmission of SARS-CoV-2. This study recommends more research into both occupant and building-related indicators as well as cross-modal effects between various IEQ factors for developing future standards on sports facilities.
Collapse
Affiliation(s)
- Dadi Zhang
- Chair Indoor Environment, Faculty of Architecture and the Built Environment, Delft University of Technology, Delf, The Netherlands
| | - Marco A Ortiz
- Chair Indoor Environment, Faculty of Architecture and the Built Environment, Delft University of Technology, Delf, The Netherlands
| | - Philomena M Bluyssen
- Chair Indoor Environment, Faculty of Architecture and the Built Environment, Delft University of Technology, Delf, The Netherlands
| |
Collapse
|
10
|
Szulc J, Okrasa M, Ryngajłło M, Pielech-Przybylska K, Gutarowska B. Markers of Chemical and Microbiological Contamination of the Air in the Sport Centers. Molecules 2023; 28:molecules28083560. [PMID: 37110794 PMCID: PMC10144153 DOI: 10.3390/molecules28083560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 04/11/2023] [Accepted: 04/17/2023] [Indexed: 04/29/2023] Open
Abstract
This study aimed to assess the markers of chemical and microbiological contamination of the air at sport centers (e.g., the fitness center in Poland) including the determination of particulate matter, CO2, formaldehyde (DustTrak™ DRX Aerosol Monitor; Multi-functional Air Quality Detector), volatile organic compound (VOC) concentration (headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry), the number of microorganisms in the air (culture methods), and microbial biodiversity (high-throughput sequencing on the Illumina platform). Additionally the number of microorganisms and the presence of SARS-CoV-2 (PCR) on the surfaces was determined. Total particle concentration varied between 0.0445 mg m-3 and 0.0841 mg m-3 with the dominance (99.65-99.99%) of the PM2.5 fraction. The CO2 concentration ranged from 800 ppm to 2198 ppm, while the formaldehyde concentration was from 0.005 mg/m3 to 0.049 mg m-3. A total of 84 VOCs were identified in the air collected from the gym. Phenol, D-limonene, toluene, and 2-ethyl-1-hexanol dominated in the air at the tested facilities. The average daily number of bacteria was 7.17 × 102 CFU m-3-1.68 × 103 CFU m-3, while the number of fungi was 3.03 × 103 CFU m-3-7.34 × 103 CFU m-3. In total, 422 genera of bacteria and 408 genera of fungi representing 21 and 11 phyla, respectively, were detected in the gym. The most abundant bacteria and fungi (>1%) that belonged to the second and third groups of health hazards were: Escherichia-Shigella, Corynebacterium, Bacillus, Staphylococcus, Cladosporium, Aspergillus, and Penicillium. In addition, other species that may be allergenic (Epicoccum) or infectious (Acinetobacter, Sphingomonas, Sporobolomyces) were present in the air. Moreover, the SARS-CoV-2 virus was detected on surfaces in the gym. The monitoring proposal for the assessment of the air quality at a sport center includes the following markers: total particle concentration with the PM2.5 fraction, CO2 concentration, VOCs (phenol, toluene, and 2-ethyl-1-hexanol), and the number of bacteria and fungi.
Collapse
Affiliation(s)
- Justyna Szulc
- Department of Environmental Biotechnology, Lodz University of Technology, 90-530 Łódź, Poland
| | - Małgorzata Okrasa
- Department of Personal Protective Equipment, Central Institute for Labour Protection-National Research Institute, 90-133 Łódź, Poland
| | - Małgorzata Ryngajłło
- Institute of Molecular and Industrial Biotechnology, Lodz University of Technology, 90-573 Łódź, Poland
| | | | - Beata Gutarowska
- Department of Environmental Biotechnology, Lodz University of Technology, 90-530 Łódź, Poland
| |
Collapse
|
11
|
Jiang Z, Deng Z, Wang X, Dong B. PANDEMIC: Occupancy driven predictive ventilation control to minimize energy consumption and infection risk. APPLIED ENERGY 2023; 334:120676. [PMID: 36714219 PMCID: PMC9867897 DOI: 10.1016/j.apenergy.2023.120676] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 01/06/2023] [Accepted: 01/08/2023] [Indexed: 05/31/2023]
Abstract
During the SARS-CoV-2 (COVID-19) pandemic, governments around the world have formulated policies requiring ventilation systems to operate at a higher outdoor fresh air flow rate for a sufficient time, which has led to a sharp increase in building energy consumption. Therefore, it is necessary to identify an energy-efficient ventilation strategy to reduce the risk of infection. In this study, we developed an occupant-number-based model predictive control (OBMPC) algorithm for building ventilation systems. First, we collected the occupancy and Heating, ventilation, and air conditioning system (HVAC) data from March to July 2021. Then, four different models (Auto regression moving average-based multilayer perceptron (ARMA_MLP), Recurrent neural networks (RNN), Long short-term memory networks (LSTM), and Nonhomogeneous Markov with change points detection (NH_Markov)) were used to predict the number of room occupants from 15 min to 24 h ahead with an interval output. We found that each model could predict the number of occupants with 85 % accuracy using a one-person offset. The accuracy of 15 min of the ahead prediction could reach 95 % with a one-person offset, but none of them could track abrupt changes. The occupancy prediction results were used to calculate the ventilation demand using the Wells-Riley equation, and the upper bound can maintain an infection risk lower than 2 % for 93 % of the day. This OBMPC model could reduce the coil load by 52.44 % and shift the peak load by 3 h up to 5 kW compared with 24 × 7 h full outdoor air (OA) system when people wear masks in the space. The occupancy prediction uncertainty could cause a 9 % to 26 % difference in demand ventilation, a 0.3 °C to 2.4 °C difference in zone temperature, a 28.5 % to 44.5 % difference in outdoor airflow rate, and a 10.7 % to 28.2 % difference in coil load.
Collapse
Affiliation(s)
- Zixin Jiang
- Department of Mechanical & Aerospace Engineering, Syracuse University, Syracuse, NY 13244, United States
- Built Environment Science and Technology (BEST) Lab, Syracuse University, Syracuse, NY 13244, United States
| | - Zhipeng Deng
- Department of Mechanical & Aerospace Engineering, Syracuse University, Syracuse, NY 13244, United States
- Built Environment Science and Technology (BEST) Lab, Syracuse University, Syracuse, NY 13244, United States
| | - Xuezheng Wang
- Department of Mechanical & Aerospace Engineering, Syracuse University, Syracuse, NY 13244, United States
- Built Environment Science and Technology (BEST) Lab, Syracuse University, Syracuse, NY 13244, United States
| | - Bing Dong
- Department of Mechanical & Aerospace Engineering, Syracuse University, Syracuse, NY 13244, United States
- Built Environment Science and Technology (BEST) Lab, Syracuse University, Syracuse, NY 13244, United States
| |
Collapse
|
12
|
Andersson M(A, Vornanen-Winqvist C, Koivisto T, Varga A, Mikkola R, Kredics L, Salonen H. Composition of Culturable Microorganisms in Dusts Collected from Sport Facilities in Finland during the COVID-19 Pandemic. Pathogens 2023; 12:pathogens12020339. [PMID: 36839611 PMCID: PMC9963892 DOI: 10.3390/pathogens12020339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 02/03/2023] [Accepted: 02/15/2023] [Indexed: 02/19/2023] Open
Abstract
Sport facilities represent extreme indoor environments due to intense cleaning and disinfection. The aim of this study was to describe the composition of the cultivated microbiota in dust samples collected in sport facilities during the COVID-19 pandemic. A dust sample is defined as the airborne dust sedimented on 0.02 m2 within 28 d. The results show that the microbial viable counts in samples of airborne dust (n = 9) collected from seven Finnish sport facilities during the pandemic contained a high proportion of pathogenic filamentous fungi and a low proportion of bacteria. The microbial viable counts were between 14 CFU and 189 CFU per dust sample. In seven samples from sport facilities, 20-85% of the microbial viable counts were fungi. Out of 123 fungal colonies, 47 colonies belonged to the potentially pathogenic sections of Aspergillus (Sections Fumigati, Nigri, and Flavi). Representatives of each section were identified as Aspergillus fumigatus, A. flavus, A. niger and A. tubingensis. Six colonies belonged to the genus Paecilomyces. In six samples of dust, a high proportion (50-100%) of the total fungal viable counts consisted of these potentially pathogenic fungi. A total of 70 isolates were considered less likely to be pathogenic, and were identified as Aspergillus section Nidulantes, Chaetomium cochliodes and Penicillium sp. In the rural (n = 2) and urban (n = 7) control dust samples, the microbial viable counts were >2000 CFU and between 44 CFU and 215 CFU, respectively, and consisted mainly of bacteria. The low proportion of bacteria and the high proportion of stress tolerant, potentially pathogenic fungi in the dust samples from sport facilities may reflect the influence of disinfection on microbial communities.
Collapse
Affiliation(s)
- Maria (Aino) Andersson
- Department of Civil Engineering, School of Engineering, Aalto University, P.O. Box 12100, FI-00076 Aalto, Finland
- Correspondence: ; Tel.: +358-405-508-934
| | - Camilla Vornanen-Winqvist
- Department of Civil Engineering, School of Engineering, Aalto University, P.O. Box 12100, FI-00076 Aalto, Finland
| | - Tuomas Koivisto
- Department of Civil Engineering, School of Engineering, Aalto University, P.O. Box 12100, FI-00076 Aalto, Finland
| | - András Varga
- Department of Microbiology, Faculty of Science and Informatics, University of Szeged, Közép Fasor 52, H-6726 Szeged, Hungary
| | - Raimo Mikkola
- Department of Civil Engineering, School of Engineering, Aalto University, P.O. Box 12100, FI-00076 Aalto, Finland
| | - László Kredics
- Department of Microbiology, Faculty of Science and Informatics, University of Szeged, Közép Fasor 52, H-6726 Szeged, Hungary
| | - Heidi Salonen
- Department of Civil Engineering, School of Engineering, Aalto University, P.O. Box 12100, FI-00076 Aalto, Finland
- International Laboratory for Air Quality and Health, Faculty of Science, School of Earth & Atmospheric Sciences, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000, Australia
| |
Collapse
|
13
|
Hung A, Koch S, Bougault V, Gee CM, Bertuzzi R, Elmore M, McCluskey P, Hidalgo L, Garcia-Aymerich J, Koehle MS. Personal strategies to mitigate the effects of air pollution exposure during sport and exercise: a narrative review and position statement by the Canadian Academy of Sport and Exercise Medicine and the Canadian Society for Exercise Physiology. Br J Sports Med 2023; 57:193-202. [PMID: 36623867 DOI: 10.1136/bjsports-2022-106161] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/17/2022] [Indexed: 01/11/2023]
Abstract
Air pollution is among the leading environmental threats to health around the world today, particularly in the context of sports and exercise. With the effects of air pollution, pollution episodes (eg, wildfire conflagrations) and climate change becoming increasingly apparent to the general population, so have their impacts on sport and exercise. As such, there has been growing interest in the sporting community (ie, athletes, coaches, and sports science and medicine team members) in practical personal-level actions to reduce the exposure to and risk of air pollution. Limited evidence suggests the following strategies may be employed: minimising all exposures by time and distance, monitoring air pollution conditions for locations of interest, limiting outdoor exercise, using acclimation protocols, wearing N95 face masks and using antioxidant supplementation. The overarching purpose of this position statement by the Canadian Academy of Sport and Exercise Medicine and the Canadian Society for Exercise Physiology is to detail the current state of evidence and provide recommendations on implementing these personal strategies in preventing and mitigating the adverse health and performance effects of air pollution exposure during exercise while recognising the limited evidence base.
Collapse
Affiliation(s)
- Andy Hung
- School of Kinesiology, The University of British Columbia, Vancouver, British Columbia, Canada
| | - Sarah Koch
- Barcelona Institute for Global Health, Barcelona, Catalonia, Spain.,Universitat Pompeu Fabra, Barcelona, Catalonia, Spain
| | - Valerie Bougault
- Laboratoire Motricité Humaine Expertise Sport Santé, Université Côte d'Azur, Nice, France
| | - Cameron Marshall Gee
- International Collaboration on Repair Discoveries, Faculty of Medicine, The University of British Columbia, Vancouver, British Columbia, Canada.,Athletics Canada, Ottawa, Ontario, Canada
| | - Romulo Bertuzzi
- Endurance Performance Research Group, School of Physical Education and Sport, University of São Paulo, São Paulo, Brazil
| | | | - Paddy McCluskey
- Athletics Canada, Ottawa, Ontario, Canada.,Canadian Sport Institute - Pacific, Victoria, British Columbia, Canada
| | - Laura Hidalgo
- Barcelona Institute for Global Health, Barcelona, Catalonia, Spain.,Universitat Pompeu Fabra, Barcelona, Catalonia, Spain
| | - Judith Garcia-Aymerich
- Barcelona Institute for Global Health, Barcelona, Catalonia, Spain.,Universitat Pompeu Fabra, Barcelona, Catalonia, Spain
| | - Michael Stephen Koehle
- School of Kinesiology, The University of British Columbia, Vancouver, British Columbia, Canada .,Division of Sport & Exercise Medicine, Faculty of Medicine, The University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
14
|
Szulc J, Cichowicz R, Gutarowski M, Okrasa M, Gutarowska B. Assessment of Dust, Chemical, Microbiological Pollutions and Microclimatic Parameters of Indoor Air in Sports Facilities. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:1551. [PMID: 36674305 PMCID: PMC9865041 DOI: 10.3390/ijerph20021551] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 01/11/2023] [Accepted: 01/12/2023] [Indexed: 05/13/2023]
Abstract
The aim of this study was to analyse the quality of indoor air in sport facilities in one of the sport centres in Poland with respect to microclimatic parameters (temperature, humidity, and air flow velocity), particulate matter concentrations (PM10, PM4, PM2.5, and PM1), gas concentrations (oxygen, ozone, hydrogen sulphide, sulphur dioxide, volatile organic compounds, and benzopyrene), and microbial contamination (the total number of bacteria, specifically staphylococci, including Staphylococcus aureus, haemolytic bacteria, Enterobacteriaceae, Pseudomonas fluorescens, actinomycetes, and the total number of fungi and xerophilic fungi). Measurements were made three times in May 2022 at 28 sampling points in 5 different sporting areas (the climbing wall, swimming pool, swimming pool changing room, and basketball and badminton courts) depending on the time of day (morning or afternoon) and on the outside building. The obtained results were compared with the standards for air quality in sports facilities. The air temperature (21−31 °C) was at the upper limit of thermal comfort, while the air humidity (RH < 40%) in the sports halls in most of the locations was below demanded values. The values for dust pollution in all rooms, except the swimming pool, exceeded the permissible limits, especially in the afternoons. Climatic conditions correlated with a high concentration of dust in the indoor air. Particulate matter concentrations of all fractions exceeded the WHO guidelines in all researched premises; the largest exceedances of standards occurred for PM2.5 (five-fold) and for PM10 (two-fold). There were no exceedances of gaseous pollutant concentrations in the air, except for benzopyrene, which resulted from the influence of the outside air. The total number of bacteria (5.1 × 101−2.0 × 104 CFU m−3) and fungi (3.0 × 101−3.75 × 102 CFU m−3) was exceeded in the changing room and the climbing wall hall. An increased number of staphylococci in the afternoon was associated with a large number of people training. The increased concentration of xerophilic fungi in the air correlated with the high dust content and low air humidity. Along with the increase in the number of users in the afternoon and their activities, the concentration of dust (several times) and microorganisms (1−2 log) in the air increased by several times and 1−2 log, respectively. The present study indicates which air quality parameters should be monitored and provides guidelines on how to increase the comfort of those who practice sports and work in sports facilities.
Collapse
Affiliation(s)
- Justyna Szulc
- Department of Environmental Biotechnology, Faculty of Biotechnology and Food Science, Lodz University of Technology, Wólczańska 171/173, 90-530 Łódź, Poland
| | - Robert Cichowicz
- Institute of Environmental Engineering and Building Installations, Faculty of Civil Engineering, Architecture and Environmental Engineering, Lodz University of Technology, Al. Politechniki 6, 90-924 Łódź, Poland
| | - Michał Gutarowski
- Institute of Environmental Engineering and Building Installations, Faculty of Civil Engineering, Architecture and Environmental Engineering, Lodz University of Technology, Al. Politechniki 6, 90-924 Łódź, Poland
| | - Małgorzata Okrasa
- Department of Personal Protective Equipment, Central Institute for Labour Protection—National Research Institute, 90-133 Łódź, Poland
| | - Beata Gutarowska
- Department of Environmental Biotechnology, Faculty of Biotechnology and Food Science, Lodz University of Technology, Wólczańska 171/173, 90-530 Łódź, Poland
| |
Collapse
|
15
|
Dong X, Yang S, Zhang C. Air Pollution Increased the Demand for Gym Sports under COVID-19: Evidence from Beijing, China. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:12614. [PMID: 36231914 PMCID: PMC9566646 DOI: 10.3390/ijerph191912614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/26/2022] [Accepted: 09/27/2022] [Indexed: 06/16/2023]
Abstract
Air pollution may change people's gym sports behavior. To test this claim, first, we used big data crawler technology and ordinary least square (OLS) models to investigate the effect of air pollution on people' gym visits in Beijing, China, especially under the COVID-19 pandemic of 2019-2020, and the results showed that a one-standard-deviation increase in PM2.5 concentration (fine particulate matter with diameters equal to or smaller than 2.5 μm) derived from the land use regression model (LUR) was positively associated with a 0.119 and a 0.171 standard-deviation increase in gym visits without or with consideration of the COVID-19 variable, respectively. Second, using spatial autocorrelation analysis and a series of spatial econometric models, we provided consistent evidence that the gym industry of Beijing had a strong spatial dependence, and PM2.5 and its spatial spillover effect had a positive impact on the demand for gym sports. Such a phenomenon offers us a new perspective that gym sports can be developed into an essential activity for the public due to this avoidance behavior regarding COVID-19 virus contact and pollution exposure.
Collapse
Affiliation(s)
- Xin Dong
- School of Information Engineering, China University of Geosciences, Beijing 100083, China
| | - Shili Yang
- Beijing Meteorological Observation Centre, Beijing Meteorological Bureau, Beijing 100089, China
| | - Chunxiao Zhang
- School of Information Engineering, China University of Geosciences, Beijing 100083, China
| |
Collapse
|
16
|
Salthammer T. Microplastics and their Additives in the Indoor Environment. Angew Chem Int Ed Engl 2022; 61:e202205713. [PMID: 35670249 PMCID: PMC9400961 DOI: 10.1002/anie.202205713] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Indexed: 11/15/2022]
Abstract
Analyses of air and house dust have shown that pollution of the indoor environment with microplastics could pose a fundamental hygienic problem. Indoor microplastics can result from abrasion, microplastic beads are frequently added to household products and microplastic granules can be found in artificial turf for sports activities and in synthetic admixtures in equestrian hall litter. In this context, the question arose as to what extent particulate emissions of thermoplastic materials from 3D printing should be at least partially classified as microplastics or nanoplastics. The discussion about textiles as a possible source of indoor microplastics has also been intensified. This Minireview gives an overview of the current exposure of residents to microplastics. Trends can be identified from the results and preventive measures can be derived if necessary. It is recommended that microplastics and their additives be given greater consideration in indoor environmental surveys in the future.
Collapse
Affiliation(s)
- Tunga Salthammer
- Department of Material Analysis and Indoor Chemistry Fraunhofer WKI Bienroder Weg 54 E 38108 Braunschweig Germany
| |
Collapse
|
17
|
Uhde E, Salthammer T, Wientzek S, Springorum A, Schulz J. Effectiveness of air-purifying devices and measures to reduce the exposure to bioaerosols in school classrooms. INDOOR AIR 2022; 32:e13087. [PMID: 36040280 DOI: 10.1111/ina.13087] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 07/12/2022] [Indexed: 06/15/2023]
Abstract
The SARS-CoV-2 pandemic, which suddenly appeared at the beginning of 2020, revealed our knowledge deficits in terms of ventilation and air pollution control. It took many weeks to realize that aerosols are the main route of transmission. The initial attempt to hold back these aerosols through textile masks seemed almost helpless, although there is sufficient knowledge about the retention capacity of fabric filters for aerosols. In the absence of a sufficient number of permanently installed heating, ventilation, and air conditioning systems, three main approaches are pursued: (a) increasing the air exchange rate by supplying fresh air, (b) using mobile air purifiers, and (c) disinfection by introducing active substances into the room air. This article discusses the feasibility of these different approaches critically. It also provides experimental results of air exchange measurements in a school classroom that is equipped with a built-in fan for supplying fresh air. With such a fan and a window tilted at the appropriate distance, an air exchange rate of 5/h can be set at a low power level and without any significant noise pollution. Heat balance calculations show that no additional heat exchanger is necessary in a normal classroom with outside temperatures above 10°C. Furthermore, a commercial mobile air purifier is studied in a chamber and a test room setup in order to examine and evaluate the efficiency of such devices against viable viruses under controlled and realistic conditions. For this purpose, bacteriophages of the type MS2 are used. Both window ventilation and air purifiers were found to be suitable to reduce the concentration of phages in the room.
Collapse
Affiliation(s)
- Erik Uhde
- Department of Material Analysis and Indoor Chemistry, Fraunhofer WKI, Braunschweig, Germany
| | - Tunga Salthammer
- Department of Material Analysis and Indoor Chemistry, Fraunhofer WKI, Braunschweig, Germany
| | - Sebastian Wientzek
- Department of Material Analysis and Indoor Chemistry, Fraunhofer WKI, Braunschweig, Germany
| | - Annette Springorum
- Department of Material Analysis and Indoor Chemistry, Fraunhofer WKI, Braunschweig, Germany
| | - Jochen Schulz
- Institute for Animal Hygiene, Animal Welfare and Farm Animal Behaviour, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany
| |
Collapse
|
18
|
Huessler EM, Hüsing A, Vancraeyenest M, Jöckel KH, Schröder B. Air quality in an air ventilated fitness center reopening for pilot study during COVID-19 pandemic lockdown. BUILDING AND ENVIRONMENT 2022; 219:109180. [PMID: 35581988 PMCID: PMC9098400 DOI: 10.1016/j.buildenv.2022.109180] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 05/05/2022] [Accepted: 05/06/2022] [Indexed: 05/07/2023]
Abstract
During COVID-19 lockdowns less people were able to fulfill the WHO recommendations on physical activity. Also, fitness centers were associated to SARS-CoV-2 superspreader events. However, the risk of infection can be strongly reduced by outdoor air ventilation. To investigate whether a reopening of fitness centers can be justified,CO 2 concentration was measured during four days in a fitness center. Except for one room, the observedCO 2 concentrations were mainly under 800 ppm, which stands for high air quality. The strong decrease ofCO 2 concentration during the 15 min evacuations following each hour of workout, speaks for the functionality of the ventilation system. In particular, the number of people present in the studio has a strong impact on the estimatedCO 2 value. In a linear mixed model, an additionalCO 2 concentration of 2.24 ppm (95 % confidence interval [2.04, 2.43]) was estimated for this setting with a total volume of 4065 m3 in the fitness center and a possible air change rate per hour up to 10. This means, that for 45 visitors, 100 ppm can be added to the predicted concentration. To summarize, a combination of ventilation, restriction of the number of visitors and surveying theCO 2 concentration allowing for further restrictions in case of need, seems to be an adequate means to reduce the risk of SARS-CoV-2 infection in fitness centers.
Collapse
Affiliation(s)
- Eva-Maria Huessler
- Institute of Medical Informatics, Biometry and Epidemiology (IMIBE), University Hospital Essen, Hufelandstraße 35, 45147 Essen, Germany
| | - Anika Hüsing
- Institute of Medical Informatics, Biometry and Epidemiology (IMIBE), University Hospital Essen, Hufelandstraße 35, 45147 Essen, Germany
| | | | - Karl-Heinz Jöckel
- Institute of Medical Informatics, Biometry and Epidemiology (IMIBE), University Hospital Essen, Hufelandstraße 35, 45147 Essen, Germany
| | - Bernadette Schröder
- Institute of Medical Informatics, Biometry and Epidemiology (IMIBE), University Hospital Essen, Hufelandstraße 35, 45147 Essen, Germany
| |
Collapse
|
19
|
Salthammer T. Microplastics and their Additives in the Indoor Environment. Angew Chem Int Ed Engl 2022. [DOI: 10.1002/ange.202205713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Tunga Salthammer
- Fraunhofer WKI Material Analysis and Indoor Chemistry Bienroder Weg 54 E 38108 Braunschweig GERMANY
| |
Collapse
|
20
|
Li H, Shankar SN, Witanachchi CT, Lednicky JA, Loeb JC, Alam MM, Fan ZH, Mohamed K, Eiguren-Fernandez A, Wu CY. Environmental Surveillance and Transmission Risk Assessments for SARS-CoV-2 in a Fitness Center. AEROSOL AND AIR QUALITY RESEARCH 2021; 21:210106. [PMID: 35047025 PMCID: PMC8765736 DOI: 10.4209/aaqr.210106] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Fitness centers are considered high risk for SARS-CoV-2 transmission due to their high human occupancy and the type of activity taking place in them, especially when individuals pre-symptomatic or asymptomatic for COVID-19 exercise in the facilities. In this study, air (N=21) and surface (N=8) samples were collected at a fitness center through five sampling events from August to November 2020 after the reopening restrictions were lifted in Florida. The total attendance was ~2500 patrons during our air and environmental sampling work. Air samples were collected using stationary and personal bioaerosol samplers. Moistened flocked nylon swabs were used to collect samples from high-touch surfaces. We did not detect SARS-CoV-2 by rRT-PCR analyses in any air or surface sample. A simplified infection risk model based on the Wells-Riley equation predicts that the probability of infection in this fitness center was 1.77% following its ventilation system upgrades based on CDC guidelines, and that risk was further reduced to 0.89% when patrons used face masks. Our model also predicts that a combination of high ventilation, minimal air recirculation, air filtration, and UV sterilization of recirculated air reduced the infection risk up to 94% compared to poorly ventilated facilities. Amongst these measures, high ventilation with outdoor air is most critical in reducing the airborne transmission of SARS-CoV-2. For buildings that cannot avoid air recirculation due to energy costs, the use of high filtration and/or air disinfection devices are alternatives to reducing the probability of acquiring SARS-CoV-2 through inhalation exposure. In contrast to the perceived ranking of high risk, the infection risk in fitness centers that follow CDC reopening guidance, including implementation of engineering and administrative controls, and use of personal protective equipment, can be low, and these facilities can offer a relatively safe venue for patrons to exercise.
Collapse
Affiliation(s)
- Hongwan Li
- Department of Environmental Engineering Sciences, University of Florida, USA
| | | | | | - John A Lednicky
- Department of Environmental and Global Health, University of Florida, USA
- Emerging Pathogens Institute, University of Florida, USA
| | - Julia C Loeb
- Department of Environmental and Global Health, University of Florida, USA
- Emerging Pathogens Institute, University of Florida, USA
| | - Md Mahbubul Alam
- Department of Environmental and Global Health, University of Florida, USA
- Emerging Pathogens Institute, University of Florida, USA
| | - Z Hugh Fan
- Department of Mechanical & Aerospace Engineering, University of Florida, USA
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, USA
| | - Karim Mohamed
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, USA
| | | | - Chang-Yu Wu
- Department of Environmental Engineering Sciences, University of Florida, USA
| |
Collapse
|
21
|
Time-Resolved Characterization of Indoor Air Quality due to Human Activity and Likely Outdoor Sources during Early Evening Secondary School Wrestling Matches. JOURNAL OF ENVIRONMENTAL AND PUBLIC HEALTH 2021; 2021:5580616. [PMID: 34211558 PMCID: PMC8205592 DOI: 10.1155/2021/5580616] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 05/13/2021] [Accepted: 05/27/2021] [Indexed: 11/17/2022]
Abstract
Despite positive health outcomes associated with physical activity as well as individual and team sports, poor indoor air and environmental quality can adversely affect human health, performance, and comfort. We conducted a 14-month field case study incorporating two winter sports regular seasons (12/2017-2/2019) including analyses of particulate matter (PMx) in air and in dust, carbon dioxide (CO2), temperature, and relative humidity (RH%) during secondary or high school wrestling activities in southern New Jersey, USA. After planning and piloting methods during the first winter sports regular season (12/2017-2/2018), during the second winter sports regular season (1-2/2019), we conducted a purposeful simultaneous real-time sampling midgymnasium adjacent to the wrestling mats. Gymnasium occupancy ranged 100-500 people. Data collected included inhalable PM10 resuspended from floor mats, fine respirable PM2.5, and indoor CO2, temperature, and RH%. Short-term real-time elevated PM10 levels were directly compared with simultaneously documented wrestling match bouts, e.g., student-athlete takedowns and pins. PM10 and PM2.5 levels were compared with other known documented activities indoors (e.g., snack bar) and sources outdoors (e.g., adjacent parking lot and major freeway). To understand CO2, temperature, and RH% data, we characterized the HS gym mechanical ventilation system-no doors or windows outdoors-and recorded occupancy during match hours. Indoor CO2 levels ranged ∼700-1000 ppm during match #1 on 1/23/2019 but ranged from ∼900 to 1900 ppm during match #2 on 1/30/2019, with >1000 ppm for the majority of the time (and throughout the entire varsity match when occupancy was at maximum). Future research should further characterize PM10 constituents in mat dust and indoor air with larger samples of schools and matches.
Collapse
|
22
|
Ramachandran HJ, Jiang Y, Shan CH, Tam WWS, Wang W. A systematic review and meta-analysis on the effectiveness of swimming on lung function and asthma control in children with asthma. Int J Nurs Stud 2021; 120:103953. [PMID: 34051586 DOI: 10.1016/j.ijnurstu.2021.103953] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 04/02/2021] [Accepted: 04/14/2021] [Indexed: 11/19/2022]
Abstract
BACKGROUND Swimming has been considered the most appropriate activity for children with asthma for its lower asthmogenicity compared to land-based activities. However, the benefits of swimming have been hampered by reports of increased asthma risks, airway inflammation and bronchial hyper-responsiveness from exposure to chlorine by-products in swimming pools. Thus, the role of swimming for children with asthma remains unclear. OBJECTIVES To determine the effectiveness of swimming as an intervention on lung function and asthma control in children below the age of 18 years. Any adverse effects from swimming on asthma were also examined. METHODS Searches were performed across six databases systematically (PubMed, CINAHL, Embase, CENTRAL, Scopus, and PsycINFO). Randomized controlled trials (RCTs), quasi-experimental studies and interventional studies with at least one control/comparator group that were published in English were included. All eligible studies were screened with risk of bias examined by two independent reviewers. Meta-analyses were conducted using Review Manager 5.4 software while narrative syntheses were performed where meta-analysis was inappropriate and heterogeneity was present. RESULTS 1710 records were retrieved from the search. A total of 9 studies with 387 participants were included in this review after screening. Swimming was found to have favourable effects on forced expiratory volume in one second (L) and forced vital capacity (%), but not for forced expiratory volume in one second (%) and peak expiratory flow (%). Narrative synthesis on asthma control and adverse effects were in favour of the swimming group. CONCLUSION Future studies that are adequately powered, involve swimming interventions of sufficient intensity, frequency and duration, examine cumulative exposures to chlorine by-products and take into account potential cofounders are warranted.
Collapse
Affiliation(s)
- Hadassah Joann Ramachandran
- Alice Lee Centre for Nursing Studies, Yong Loo Lin School of Medicine, National University of Singapore, Level 2, Clinical Research Centre, Block MD 11,10 Medical Drive, Singapore 117597, Singapore.
| | - Ying Jiang
- Alice Lee Centre for Nursing Studies, Yong Loo Lin School of Medicine, National University of Singapore, Level 2, Clinical Research Centre, Block MD 11,10 Medical Drive, Singapore 117597, Singapore.
| | - Coral Hui Shan
- Alice Lee Centre for Nursing Studies, Yong Loo Lin School of Medicine, National University of Singapore, Level 2, Clinical Research Centre, Block MD 11,10 Medical Drive, Singapore 117597, Singapore.
| | - Wilson Wai San Tam
- Alice Lee Centre for Nursing Studies, Yong Loo Lin School of Medicine, National University of Singapore, Level 2, Clinical Research Centre, Block MD 11,10 Medical Drive, Singapore 117597, Singapore.
| | - Wenru Wang
- Alice Lee Centre for Nursing Studies, Yong Loo Lin School of Medicine, National University of Singapore, Level 2, Clinical Research Centre, Block MD 11,10 Medical Drive, Singapore 117597, Singapore.
| |
Collapse
|
23
|
Blocken B, van Druenen T, Ricci A, Kang L, van Hooff T, Qin P, Xia L, Ruiz CA, Arts JH, Diepens JFL, Maas GA, Gillmeier SG, Vos SB, Brombacher AC. Ventilation and air cleaning to limit aerosol particle concentrations in a gym during the COVID-19 pandemic. BUILDING AND ENVIRONMENT 2021; 193:107659. [PMID: 33568882 PMCID: PMC7860965 DOI: 10.1016/j.buildenv.2021.107659] [Citation(s) in RCA: 56] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Revised: 01/28/2021] [Accepted: 01/31/2021] [Indexed: 05/03/2023]
Abstract
SARS-CoV-2 can spread by close contact through large droplet spray and indirect contact via contaminated objects. There is mounting evidence that it can also be transmitted by inhalation of infected saliva aerosol particles. These particles are generated when breathing, talking, laughing, coughing or sneezing. It can be assumed that aerosol particle concentrations should be kept low in order to minimize the potential risk of airborne virus transmission. This paper presents measurements of aerosol particle concentrations in a gym, where saliva aerosol production is pronounced. 35 test persons performed physical exercise and aerosol particle concentrations, CO2 concentrations, air temperature and relative humidity were obtained in the room of 886 m³. A separate test was used to discriminate between human endogenous and exogenous aerosol particles. Aerosol particle removal by mechanical ventilation and mobile air cleaning units was measured. The gym test showed that ventilation with air-change rate ACH = 2.2 h-1, i.e. 4.5 times the minimum of the Dutch Building Code, was insufficient to stop the significant aerosol concentration rise over 30 min. Air cleaning alone with ACH = 1.39 h-1 had a similar effect as ventilation alone. Simplified mathematical models were engaged to provide further insight into ventilation, air cleaning and deposition. It was shown that combining the above-mentioned ventilation and air cleaning can reduce aerosol particle concentrations with 80 to 90% , depending on aerosol size. This combination of existing ventilation supplemented with air cleaning is energy efficient and can also be applied for other indoor environments.
Collapse
Affiliation(s)
- B Blocken
- Unit Building Physics and Services, Department of the Built Environment, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven, the Netherlands
- Building Physics and Sustainable Design, Department of Civil Engineering, KU Leuven, Kasteelpark Arenberg 40 - Bus 2447, 3001, Leuven, Belgium
| | - T van Druenen
- Unit Building Physics and Services, Department of the Built Environment, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven, the Netherlands
| | - A Ricci
- Unit Building Physics and Services, Department of the Built Environment, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven, the Netherlands
- Building Physics and Sustainable Design, Department of Civil Engineering, KU Leuven, Kasteelpark Arenberg 40 - Bus 2447, 3001, Leuven, Belgium
- Department of Civil, Chemical and Environmental Engineering, University of Genoa, Genoa, Italy
| | - L Kang
- Unit Building Physics and Services, Department of the Built Environment, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven, the Netherlands
| | - T van Hooff
- Unit Building Physics and Services, Department of the Built Environment, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven, the Netherlands
| | - P Qin
- Unit Building Physics and Services, Department of the Built Environment, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven, the Netherlands
| | - L Xia
- Unit Building Physics and Services, Department of the Built Environment, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven, the Netherlands
| | - C Alanis Ruiz
- Building Physics and Sustainable Design, Department of Civil Engineering, KU Leuven, Kasteelpark Arenberg 40 - Bus 2447, 3001, Leuven, Belgium
| | - J H Arts
- Department of Industrial Design, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven, the Netherlands
- School of Sport Studies, Fontys University of Applied Sciences, Theo Koomenlaan 3, 5644HZ Eindhoven, the Netherlands
| | - J F L Diepens
- Unit Building Physics and Services, Department of the Built Environment, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven, the Netherlands
| | - G A Maas
- Unit Building Physics and Services, Department of the Built Environment, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven, the Netherlands
| | - S G Gillmeier
- Unit Building Physics and Services, Department of the Built Environment, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven, the Netherlands
| | - S B Vos
- Department of Industrial Design, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven, the Netherlands
- School of Sport Studies, Fontys University of Applied Sciences, Theo Koomenlaan 3, 5644HZ Eindhoven, the Netherlands
| | - A C Brombacher
- Department of Industrial Design, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven, the Netherlands
| |
Collapse
|
24
|
Pulmonary Effects Due to Physical Exercise in Polluted Air: Evidence from Studies Conducted on Healthy Humans. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11072890] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Physical inactivity has caused serious effects on the health of the population, having an impact on the quality of life and the cost of healthcare for many countries. This has motivated government and private institutions to promote regular physical activity, which, paradoxically, can involve health risks when it is carried out in areas with poor air quality. This review collects information from studies conducted on healthy humans related to the pulmonary effects caused by the practice of physical activity when there is poor air quality. In addition, several challenges related to the technological and educational areas, as well as to applied and basic research, have been identified to facilitate the rational practice of exercise in poor air quality conditions.
Collapse
|
25
|
Numerical Analysis of the Energy Consumption of Ventilation Processes in the School Swimming Pool. ENERGIES 2021. [DOI: 10.3390/en14041023] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Ventilation of an indoor swimming pool is a very energy consuming process. This is a result of, among other things the required high value of the ventilation air volume flow rate, calculated on the basis of the moisture gains in the facility. The total energy consumption consists of the heat required to heat this air and the electricity needed to transport it. It is possible to reduce the ventilation air volume flow rate by assuming the correct value of specific humidity of the supply and indoor air, but then a deterioration of thermal-moisture conditions in the building can be expected. The aim of this paper was to examine how the reduction of the supply air volume flow rate affects the energy consumption for indoor swimming pool ventilation. It was also checked how this consumption can be reduced by using two-stage heat recovery in the air handling unit. Multi-variant simulations of energy consumption for indoor swimming pool ventilation were carried out using the IDA ICE software for day and night operation of the swimming pool throughout the year. The results of the research proved that reduction of the supply air volume flow rate resulted in the lower energy expenditure on ventilation. The variant with additional local air supply to the lifeguard zone was also analysed, which caused only a slight increase in energy demand for ventilation.
Collapse
|