For: Mackenzie A, Honey ID. Characterization of noise sources for two generations of computed radiography systems using powder and crystalline photostimulable phosphors. Med Phys 2007;34:3345-57. [PMID: 17879798 DOI: 10.1118/1.2750973] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
Number Cited by Other Article(s)
1
Kim DS. Measurements of the noise power spectrum for digital x-ray imaging devices. Phys Med Biol 2024;69:03TR01. [PMID: 38157548 DOI: 10.1088/1361-6560/ad1999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Accepted: 12/29/2023] [Indexed: 01/03/2024]
2
Merken K, Monnens J, Marshall N, Johan N, Brasil DM, Santaella GM, Politis C, Jacobs R, Bosmans H. Development and validation of a 3D anthropomorphic phantom for dental CBCT imaging research. Med Phys 2023;50:6714-6736. [PMID: 37602774 DOI: 10.1002/mp.16661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 07/17/2023] [Accepted: 07/17/2023] [Indexed: 08/22/2023]  Open
3
Marshall NW, Vandenbroucke D, Cockmartin L, Wanninger F, Smet M, Feng Y, Ni Y, Bosmans H. Seven general radiography x-ray detectors with pixel sizes ranging from 175 to 76μm: technical evaluation with the focus on orthopaedic imaging. Phys Med Biol 2023;68:195007. [PMID: 37659394 DOI: 10.1088/1361-6560/acf642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Accepted: 09/01/2023] [Indexed: 09/04/2023]
4
Maruyama S. Simulation Analysis on the Performance of a Circular-Edge Technique in Measurements of the Modulation Transfer Function. J Med Phys 2023;48:90-97. [PMID: 37342601 PMCID: PMC10277299 DOI: 10.4103/jmp.jmp_54_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 11/27/2022] [Accepted: 12/07/2022] [Indexed: 06/23/2023]  Open
5
Perez A, Poletti M. Characterization of digital systems used in medical X-ray imaging. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
6
Bae K, Jeon KN, Kim JE, Park SE, Baek HJ, Moon JI, Ryu KH, Cho E. Abdominal CT in patients with arms down positioning: Effect of virtual monoenergetic reconstruction on diagnostic image quality. Abdom Radiol (NY) 2021;46:5037-5046. [PMID: 34215901 DOI: 10.1007/s00261-021-03195-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 06/22/2021] [Accepted: 06/23/2021] [Indexed: 11/26/2022]
7
Setianegara J, Mazur TR, Hao Y, Yang D, Harold Li H. Development of a storage phosphor imaging system for proton pencil beam spot profile determination. Med Phys 2021;48:5459-5471. [PMID: 34318488 DOI: 10.1002/mp.15139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 06/23/2021] [Accepted: 07/15/2021] [Indexed: 11/07/2022]  Open
8
Maruyama S. EXPOSURE DOSE INDEX BASED ON NOISE FACTOR ANALYSIS IN DIGITAL MAMMOGRAPHY: VERIFICATION USING DIRECT-TYPE FLAT-PANEL DETECTOR SYSTEM. RADIATION PROTECTION DOSIMETRY 2020;192:473-481. [PMID: 33598690 DOI: 10.1093/rpd/ncab003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 12/06/2020] [Accepted: 12/30/2020] [Indexed: 06/12/2023]
9
Comparison of physical image qualities and artifact indices for head computed tomography in the axial and helical scan modes. Phys Eng Sci Med 2020;43:557-566. [PMID: 32524440 DOI: 10.1007/s13246-020-00856-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Accepted: 02/28/2020] [Indexed: 01/28/2023]
10
Kawashima H, Ichikawa K, Takata T, Mitsui W. Algorithm-based artifact reduction in patients with arms-down positioning in computed tomography. Phys Med 2020;69:61-69. [DOI: 10.1016/j.ejmp.2019.11.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Revised: 11/06/2019] [Accepted: 11/18/2019] [Indexed: 11/25/2022]  Open
11
Marshall NW, Smet M, Hofmans M, Pauwels H, De Clercq T, Bosmans H. Technical characterization of five x-ray detectors for paediatric radiography applications. Phys Med Biol 2017;62:N573-N586. [PMID: 29064378 DOI: 10.1088/1361-6560/aa9599] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
12
An analytical approach to the light transport in columnar phosphors. Detector Optical Gain, angular distribution and the CsI:Tl paradigm. Phys Med 2017;35:39-49. [PMID: 28242138 DOI: 10.1016/j.ejmp.2017.02.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2016] [Revised: 01/23/2017] [Accepted: 02/11/2017] [Indexed: 11/24/2022]  Open
13
Van Peteghem N, Bosmans H, Marshall NW. NPWE model observer as a validated alternative for contrast detail analysis of digital detectors in general radiography. Phys Med Biol 2016;61:N575-N591. [DOI: 10.1088/0031-9155/61/21/n575] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
14
Monnin P, Bosmans H, Verdun FR, Marshall NW. A comprehensive model for quantum noise characterization in digital mammography. Phys Med Biol 2016;61:2083-108. [PMID: 26895467 DOI: 10.1088/0031-9155/61/5/2083] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
15
Mackenzie A, Dance DR, Diaz O, Young KC. Image simulation and a model of noise power spectra across a range of mammographic beam qualities. Med Phys 2014;41:121901. [PMID: 25471961 DOI: 10.1118/1.4900819] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2014] [Revised: 08/13/2014] [Accepted: 10/13/2014] [Indexed: 02/11/2024]  Open
16
Monnin P, Bosmans H, Verdun FR, Marshall NW. Comparison of the polynomial model against explicit measurements of noise components for different mammography systems. Phys Med Biol 2014;59:5741-61. [DOI: 10.1088/0031-9155/59/19/5741] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
17
Salvagnini E, Bosmans H, Struelens L, Marshall NW. Effective detective quantum efficiency for two mammography systems: measurement and comparison against established metrics. Med Phys 2014;40:101916. [PMID: 24089918 DOI: 10.1118/1.4820362] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]  Open
18
Moore CS, Wood TJ, Avery G, Balcam S, Needler L, Beavis AW, Saunderson JR. An investigation of automatic exposure control calibration for chest imaging with a computed radiography system. Phys Med Biol 2014;59:2307-24. [DOI: 10.1088/0031-9155/59/9/2307] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
19
Rivetti S, Lanconelli N, Bertolini M, Nitrosi A, Burani A. Characterization of a clinical unit for digital radiography based on irradiation side sampling technology. Med Phys 2013;40:101902. [DOI: 10.1118/1.4820364] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]  Open
20
Hansel RA, Xiao Z, Hu Y, Green O, Yang D, Harold Li H. The role of activator concentration and precipitate formation on optical and dosimetric properties of KCl:Eu(2+) storage phosphor detectors. Med Phys 2013;40:092104. [PMID: 24007173 DOI: 10.1118/1.4817522] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
21
Marshall NW, Lemmens K, Bosmans H. Physical evaluation of a needle photostimulable phosphor based CR mammography system. Med Phys 2012;39:811-24. [PMID: 22320791 DOI: 10.1118/1.3675403] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]  Open
22
Mackenzie A, Dance DR, Workman A, Yip M, Wells K, Young KC. Conversion of mammographic images to appear with the noise and sharpness characteristics of a different detector and x-ray system. Med Phys 2012;39:2721-34. [DOI: 10.1118/1.4704525] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
23
Kunitomo H, Ichikawa K, Higashide R, Ohashi K. [Physical image properties of digital radiography systems in low dose range]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2012;68:961-969. [PMID: 22975694 DOI: 10.6009/jjrt.2012_jsrt_68.8.961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
24
Feasibility of dose reduction using needle-structured image plates versus powder-structured plates for computed radiography of the knee. AJR Am J Roentgenol 2011;197:W318-23. [PMID: 21785059 DOI: 10.2214/ajr.10.5505] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
25
Berger-Kulemann V, Pötter-Lang S, Gruber M, Berger R, Vonbank K, Weber M, Rabitsch W, Uffmann M. Needle image plates compared to conventional CR in chest radiography: is dose reduction possible? Eur J Radiol 2011;81:4156-60. [PMID: 21798682 DOI: 10.1016/j.ejrad.2011.06.060] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2011] [Accepted: 06/16/2011] [Indexed: 11/24/2022]
26
Rivetti S, Lanconelli N, Bertolini M, Acchiappati D. A new clinical unit for digital radiography based on a thick amorphous Selenium plate: Physical and psychophysical characterization. Med Phys 2011;38:4480-8. [DOI: 10.1118/1.3605471] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
27
Marshall NW, Monnin P, Bosmans H, Bochud FO, Verdun FR. Image quality assessment in digital mammography: part I. Technical characterization of the systems. Phys Med Biol 2011;56:4201-20. [DOI: 10.1088/0031-9155/56/14/002] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
28
Leblans P, Vandenbroucke D, Willems P. Storage Phosphors for Medical Imaging. MATERIALS (BASEL, SWITZERLAND) 2011;4:1034-1086. [PMID: 28879966 PMCID: PMC5448636 DOI: 10.3390/ma4061034] [Citation(s) in RCA: 117] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2011] [Revised: 05/30/2011] [Accepted: 06/07/2011] [Indexed: 11/20/2022]
29
Kuhls-Gilcrist A, Jain A, Bednarek DR, Rudin S. Measuring the presampled MTF from a reduced number of flat-field images using the Noise Response (NR) method. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2011;7961. [PMID: 21731401 DOI: 10.1117/12.877890] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
30
Marshall NW, Mackenzie A, Honey ID. Quality control measurements for digital x-ray detectors. Phys Med Biol 2011;56:979-99. [PMID: 21248386 DOI: 10.1088/0031-9155/56/4/007] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
31
Ichikawa K. [Fundamentals of relationship between physical image quality and radiation dose in digital radiography]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2011;67:1473-1477. [PMID: 22104242 DOI: 10.6009/jjrt.67.1473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
32
Kuhls-Gilcrist A, Bednarek DR, Rudin S. A method for the determination of the two-dimensional MTF of digital radiography systems using only the noise response. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2010;7622:76224W-76244W9. [PMID: 21170177 DOI: 10.1117/12.843918] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
33
Vedantham S, Karellas A. Modeling the performance characteristics of computed radiography (CR) systems. IEEE TRANSACTIONS ON MEDICAL IMAGING 2010;29:790-806. [PMID: 20199915 PMCID: PMC5228607 DOI: 10.1109/tmi.2009.2036995] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
34
Kuhls-Gilcrist A, Jain A, Bednarek DR, Hoffmann KR, Rudin S. Accurate MTF measurement in digital radiography using noise response. Med Phys 2010;37:724-35. [PMID: 20229882 PMCID: PMC2821422 DOI: 10.1118/1.3284376] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2009] [Revised: 09/26/2009] [Accepted: 12/08/2009] [Indexed: 12/13/2022]  Open
35
Rivetti S, Lanconelli N, Bertolini M, Nitrosi A, Burani A, Acchiappati D. Comparison of different computed radiography systems: Physical characterization and contrast detail analysis. Med Phys 2010;37:440-8. [DOI: 10.1118/1.3284539] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
36
Rivetti S, Lanconelli N, Bertolini M, Borasi G, Golinelli P, Acchiappati D, Gallo E. Physical and psychophysical characterization of a novel clinical system for digital mammography. Med Phys 2009;36:5139-48. [DOI: 10.1118/1.3245879] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]  Open
37
Marshall NW. An examination of automatic exposure control regimes for two digital radiography systems. Phys Med Biol 2009;54:4645-70. [DOI: 10.1088/0031-9155/54/15/002] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
38
Marshall NW. Detective quantum efficiency measured as a function of energy for two full-field digital mammography systems. Phys Med Biol 2009;54:2845-61. [DOI: 10.1088/0031-9155/54/9/017] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
39
Moore CS, Saunderson JR, Beavis AW. Investigating the exposure class of a computed radiography system for optimisation of physical image quality for chest radiography. Br J Radiol 2009;82:705-10. [PMID: 19221185 DOI: 10.1259/bjr/27942950] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]  Open
40
Kuhls-Gilcrist A, Bednarek DR, Rudin S. Component analysis of a new Solid State X-ray Image Intensifier (SSXII) using photon transfer and Instrumentation Noise Equivalent Exposure (INEE) measurements. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2009;7258:7258171-72581710. [PMID: 19763251 PMCID: PMC2745170 DOI: 10.1117/12.813957] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
41
Samei E, Ranger NT, MacKenzie A, Honey ID, Dobbins JT, Ravin CE. Detector or system? Extending the concept of detective quantum efficiency to characterize the performance of digital radiographic imaging systems. Radiology 2008;249:926-37. [PMID: 19011189 PMCID: PMC2691810 DOI: 10.1148/radiol.2492071734] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
42
Honey ID, Mackenzie A. Artifacts found during quality assurance testing of computed radiography and digital radiography detectors. J Digit Imaging 2008;22:383-92. [PMID: 18427900 DOI: 10.1007/s10278-008-9109-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2007] [Revised: 01/06/2008] [Accepted: 02/07/2008] [Indexed: 10/22/2022]  Open