1
|
Kim DS. Measurements of the noise power spectrum for digital x-ray imaging devices. Phys Med Biol 2024; 69:03TR01. [PMID: 38157548 DOI: 10.1088/1361-6560/ad1999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Accepted: 12/29/2023] [Indexed: 01/03/2024]
Abstract
Objective.The noise characteristics of digital x-ray imaging devices are determined by contributions such as photon noise, electronic noise, and fixed pattern noise, and can be evaluated from measuring the noise power spectrum (NPS), which is the power spectral density of the noise. Hence, accurately measuring NPS is important in developing detectors for acquiring low-noise digital x-ray images. To make accurate measurements, it is necessary to understand NPS, identify problems that may arise, and know how to process the obtained x-ray images.Approach.The primitive concept of NPS is first introduced with a periodogram-based estimate and its bias and variance are discussed. In measuring NPS based on the IEC62220 standards, various issues, such as the fixed pattern noise, high-precision estimates, and lag corrections, are summarized with simulation examples.Main results.High-precision estimates can be provided for an appropriate number of samples extracted from x-ray images while compromising spectral resolution. Depending on medical imaging systems, by eliminating the influence of fixed pattern noise, NPS, which represents only photon and electronic noise, can be efficiently measured. For NPS measurements in dynamic detectors, an appropriate lag correction technique can be selected depending on the emitted x-rays and image acquisition process.Significance.Various issues in measuring NPS are reviewed and summarized for accurately evaluating the noise performance of digital x-ray imaging devices.
Collapse
Affiliation(s)
- Dong Sik Kim
- Department of Electronics Engineering, Hankuk University of Foreign Studies, Yongin-si, Gyeonggi-do, 449-791, Republic of Korea
| |
Collapse
|
2
|
Merken K, Monnens J, Marshall N, Johan N, Brasil DM, Santaella GM, Politis C, Jacobs R, Bosmans H. Development and validation of a 3D anthropomorphic phantom for dental CBCT imaging research. Med Phys 2023; 50:6714-6736. [PMID: 37602774 DOI: 10.1002/mp.16661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 07/17/2023] [Accepted: 07/17/2023] [Indexed: 08/22/2023] Open
Abstract
BACKGROUND Optimization of dental cone beam computed tomography (CBCT) imaging is still in a preliminary stage and should be addressed using task-based methods. Dedicated models containing relevant clinical tasks for image quality studies have yet to be developed. PURPOSE To present a methodology to develop and validate a virtual adult anthropomorphic voxel phantom for use in task-based image quality optimization studies in dental CBCT imaging research, focusing on root fracture (RF) detection tasks in the presence of metal artefacts. METHODS The phantom was developed from a CBCT scan with an isotropic voxel size of 0.2 mm, from which the main dental structures, mandible and maxilla were segmented. The missing large anatomical structures, including the spine, skull and remaining soft tissues, were segmented from a lower resolution full skull scan. Anatomical abnormalities were absent in the areas of interest. Fine detailed dental structures, that could not be segmented due to the limited resolution and noise in the clinical data, were modelled using a-priori anatomical knowledge. Model resolution of the teeth was therefore increased to 0.05 mm. Models of RFs as well as dental restorations to create the artefacts, were developed, and could be inserted in the phantom in any desired configuration. Simulated CBCT images of the models were generated using a newly developed multi-resolution simulation framework that incorporated the geometry, beam quality, noise and spatial resolution characteristics of a real dental CBCT scanner. Ray-tracing and Monte Carlo techniques were used to create the projection images, which were reconstructed using the classical FDK algorithm. Validation of the models was assessed by measurements of different tooth lengths, the pulp volume and the mandible, and comparison with reference values. Additionally, the simulated images were used in a reader study in which two oral radiologists had to score the realism level of the model's normal anatomy, as well as the modelled RFs and restorations. RESULTS A model of an adult head, as well as models of RFs and different types of dental restorations were created. Anatomical measurements were consistent with ranges reported in literature. For the tooth length measurements, the deviations from the mean reference values were less than 20%. In 77% of all the measurements, the deviations were within 10.1%. The pulp volumes, and mandible measurements were within one standard deviation of the reference values. Regarding the normal anatomy, both readers considered the realism level of the dental structures to be good. Background structures received a lower realism score due to the lack of detailed enough trabecular bone structure, which was expected but not the focus of this study. All modelled RFs were scored at least adequate by at least one of the readers, both in appearance and position. The realism level of the modelled restorations was considered to be good. CONCLUSIONS A methodology was proposed to develop and validate an anthropomorphic voxel phantom for image quality optimization studies in dental CBCT imaging, with a main focus on RF detection tasks. The methodology can be extended further to create more models representative of the clinical population.
Collapse
Affiliation(s)
- Karen Merken
- Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium
| | - Janne Monnens
- Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium
| | - Nicholas Marshall
- Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium
| | - Nuyts Johan
- Department of Imaging and Pathology, Division of Nuclear Medicine & Molecular Imaging, KU Leuven, Leuven, Belgium
| | - Danieli Moura Brasil
- Department of Diagnosis and Oral Health, School of Dentistry, University of Louisville, Louisville, Kentucky, USA
| | - Gustavo Machado Santaella
- Department of Diagnosis and Oral Health, School of Dentistry, University of Louisville, Louisville, Kentucky, USA
| | - Constantinus Politis
- Department of Imaging and Pathology, Division of Oral and Maxillofacial Surgery, KU Leuven, Leuven, Belgium
| | - Reinhilde Jacobs
- Department of Imaging and Pathology, Division of Oral and Maxillofacial Surgery, KU Leuven, Leuven, Belgium
- Department of Dental Medicine, Karolinska Institutet, Huddinge, Sweden
| | - Hilde Bosmans
- Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium
| |
Collapse
|
3
|
Marshall NW, Vandenbroucke D, Cockmartin L, Wanninger F, Smet M, Feng Y, Ni Y, Bosmans H. Seven general radiography x-ray detectors with pixel sizes ranging from 175 to 76 μm: technical evaluation with the focus on orthopaedic imaging. Phys Med Biol 2023; 68:195007. [PMID: 37659394 DOI: 10.1088/1361-6560/acf642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Accepted: 09/01/2023] [Indexed: 09/04/2023]
Abstract
Aim. Flat panel detectors with small pixel sizes general can potentially improve imaging performance in radiography applications requiring fine detail resolution. This study evaluated the imaging performance of seven detectors, covering a wide range of pixel sizes, in the frame of orthopaedic applications.Material and methods. Pixel sizes ranged from 175 (detector A175) to 76μm (detector G76). Modulation transfer function (MTF) and detective quantum efficiency (DQE) were measured using International Electrotechnical Commission (IEC) RQA3 beam quality. Threshold contrast (CT) and a detectability index (d') were measured at three air kerma/image levels. Rabbit shoulder images acquired at 60 kV, over five air kerma levels, were evaluated in a visual grading study for anatomical sharpness, image noise and overall diagnostic image quality by four radiologists. The detectors were compared to detector E124.Results. The 10% point of the MTF ranged from 3.21 to 4.80 mm-1, in going from detector A175to detector G76. DQE(0.5 mm-1) measured at 2.38μGy/image was 0.50 ± 0.05 for six detectors, but was higher for F100at 0.62. High frequency DQE was superior for the smaller pixel detectors, howeverCTfor 0.25 mm discs correlated best with DQE(0.5 mm-1). Correlation betweenCTand the detectability model was good (R2= 0.964).CTfor 0.25 mm diameter discs was significantly higher for D150and F100compared to E124. The visual grading data revealed higher image quality ratings for detectors D125and F100compared to E124. An increase in air kerma was associated with improved perceived sharpness and overall quality score, independent of detector. Detectors B150, D125, F100and G76, performed well in specific tests, however only F100consistently outperformed the reference detector.Conclusion. Pixel size alone was not a reliable predictor of small detail detectability or even perceived sharpness in a visual grading analysis study.
Collapse
Affiliation(s)
- N W Marshall
- UZ Gasthuisberg, Department of Radiology, Herestraat 49, B-3000 Leuven, Belgium
- Medical Imaging Research Center, Medical Physics and Quality Assessment, Katholieke Universiteit Leuven, B-3000 Leuven, Belgium
- Agfa N.V., Septestraat 27, B-2640 Mortsel, Belgium
| | | | - L Cockmartin
- UZ Gasthuisberg, Department of Radiology, Herestraat 49, B-3000 Leuven, Belgium
| | - F Wanninger
- Agfa-Gevaert HealthCare GmbH, München, Germany
| | - M Smet
- UZ Gasthuisberg, Department of Radiology, Herestraat 49, B-3000 Leuven, Belgium
| | - Y Feng
- Theragnostic Laboratory, Biomedical Group, Katholieke Universiteit Leuven, B-3000 Leuven, Belgium
| | - Y Ni
- Theragnostic Laboratory, Biomedical Group, Katholieke Universiteit Leuven, B-3000 Leuven, Belgium
| | - H Bosmans
- UZ Gasthuisberg, Department of Radiology, Herestraat 49, B-3000 Leuven, Belgium
- Medical Imaging Research Center, Medical Physics and Quality Assessment, Katholieke Universiteit Leuven, B-3000 Leuven, Belgium
| |
Collapse
|
4
|
Maruyama S. Simulation Analysis on the Performance of a Circular-Edge Technique in Measurements of the Modulation Transfer Function. J Med Phys 2023; 48:90-97. [PMID: 37342601 PMCID: PMC10277299 DOI: 10.4103/jmp.jmp_54_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 11/27/2022] [Accepted: 12/07/2022] [Indexed: 06/23/2023] Open
Abstract
The modulation transfer function (MTF) plays an important role in characterizing medical imaging systems. For such characterization, the circular-edge technique has become a prevalent task-based methodology. When determining the MTF with complicated task-based measurements, error factors must be well understood to properly interpret the results. In this context, the aim of this work was to study the changes in measurement performance in the analysis of the MTF using a circular edge. To eliminate the systematic error related to the measurement and suitably manage the error factors, images were generated by Monte Carlo simulation. Further, a performance comparison with the conventional method was conducted; in addition, the influence of the edge size and contrast and the setting error of the center coordinates were investigated. The difference from the true value and the standard deviation relative to the average value were applied to the index as the accuracy and precision, respectively. The results demonstrated that the smaller the circular object used and the lower the contrast, the grater the deterioration in the measurement performance. Furthermore, this study clarified the underestimating of the MTF in proportion to the square of the distance with respect to the setting error of the center position, which is important for the synthesis of the edge profile. Evaluations in the backgrounds wherein there are multiple factors affecting the results are complex, and the system users must properly judge the validity of the characterization results. These findings provide meaningful insight in the context of MTF measurement techniques.
Collapse
Affiliation(s)
- Sho Maruyama
- Department of Radiological Technology, School of Radiological Technology, Gunma Prefectural College of Health Sciences, Maebashi, Japan
| |
Collapse
|
5
|
Perez A, Poletti M. Characterization of digital systems used in medical X-ray imaging. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
6
|
Bae K, Jeon KN, Kim JE, Park SE, Baek HJ, Moon JI, Ryu KH, Cho E. Abdominal CT in patients with arms down positioning: Effect of virtual monoenergetic reconstruction on diagnostic image quality. Abdom Radiol (NY) 2021; 46:5037-5046. [PMID: 34215901 DOI: 10.1007/s00261-021-03195-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 06/22/2021] [Accepted: 06/23/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate effect of virtual monoenergetic reconstruction on contrast-enhanced abdominal CT obtained using a dual-layer detector CT (DLCT) in patients with arms-down positioning, in comparison with conventional 120-kVp image. METHODS A total of 162 consecutive patients who underwent abdominal CT scans using a DLCT with arms-down positioning were retrospectively enrolled. 120-kVp image and virtual monoenergetic images (VMIs) at 40-100 keV were compared for arm-induced artifact reduction capability and image quality through objective and subjective assessments. Diagnostic performance was compared between VMI with the best quality and 120-kVp image. RESULTS VMIs at 60-100 keV showed significantly lower (p < 0.001) artifact index than 120-kVp image. Subjective severity of arm-induced streak artifacts was significantly (p < 0.001) lower in VMIs at 70-100 keV than in 120-kVp image. CNRs measured in artifact and reference areas were superior (p < 0.05) in 40-70 keV to those in 120 kVp. Overall image quality was superior (p < 0.05) in 60-90 keV to 120 kVp. 70-keV VMI was chosen as the best image by two independent readers. In ROC analysis of lesion detection in the liver, spleen, and kidneys, the AUC was significantly higher for 70-keV VMI (reader 1, 0.962; p = 0.011; reader 2, 0.981; p = 0.012) than that for 120-kVp image (reader 1, 0.891; reader 2, 0.922). CONCLUSION The70-keV VMI from DLCT could improve abdominal CT images by reducing streak artifacts and increasing image contrast in patients who could not elevated their arms. The 70-keV VMI showed better diagnostic performance than the conventional 120 kVp image.
Collapse
Affiliation(s)
- Kyungsoo Bae
- Department of Radiology, Institute of Health Sciences, Gyeongsang National University School of Medicine, Jinju, Korea
- Department of Radiology, Gyeongsang National University Changwon Hospital, 555 Samjeongja-dong, Seongsan-gu, Changwon, Korea
| | - Kyung Nyeo Jeon
- Department of Radiology, Institute of Health Sciences, Gyeongsang National University School of Medicine, Jinju, Korea.
- Department of Radiology, Gyeongsang National University Changwon Hospital, 555 Samjeongja-dong, Seongsan-gu, Changwon, Korea.
| | - Ji Eun Kim
- Department of Radiology, Institute of Health Sciences, Gyeongsang National University School of Medicine, Jinju, Korea
- Department of Radiology, Gyeongsang National University Hospital, Jinju, Korea
| | - Sung Eun Park
- Department of Radiology, Institute of Health Sciences, Gyeongsang National University School of Medicine, Jinju, Korea
- Department of Radiology, Gyeongsang National University Changwon Hospital, 555 Samjeongja-dong, Seongsan-gu, Changwon, Korea
| | - Hye Jin Baek
- Department of Radiology, Institute of Health Sciences, Gyeongsang National University School of Medicine, Jinju, Korea
- Department of Radiology, Gyeongsang National University Changwon Hospital, 555 Samjeongja-dong, Seongsan-gu, Changwon, Korea
| | - Jin Il Moon
- Department of Radiology, Institute of Health Sciences, Gyeongsang National University School of Medicine, Jinju, Korea
- Department of Radiology, Gyeongsang National University Changwon Hospital, 555 Samjeongja-dong, Seongsan-gu, Changwon, Korea
| | - Kung Hwa Ryu
- Department of Radiology, Institute of Health Sciences, Gyeongsang National University School of Medicine, Jinju, Korea
- Department of Radiology, Gyeongsang National University Changwon Hospital, 555 Samjeongja-dong, Seongsan-gu, Changwon, Korea
| | - Eun Cho
- Department of Radiology, Institute of Health Sciences, Gyeongsang National University School of Medicine, Jinju, Korea
- Department of Radiology, Gyeongsang National University Changwon Hospital, 555 Samjeongja-dong, Seongsan-gu, Changwon, Korea
| |
Collapse
|
7
|
Setianegara J, Mazur TR, Hao Y, Yang D, Harold Li H. Development of a storage phosphor imaging system for proton pencil beam spot profile determination. Med Phys 2021; 48:5459-5471. [PMID: 34318488 DOI: 10.1002/mp.15139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 06/23/2021] [Accepted: 07/15/2021] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Accurate two-dimensional (2D) profile measurements at submillimeter precision are necessary for proton beam commissioning and periodic quality assurance (QA) purposes and are currently performed at our institution with a commercial scintillation detector (Lynx PT) with limited means for independent checks. The purpose of this work was to create an independent dosimetry system consisting of an in-house optical scanner and a BaFBrI:Eu2+ storage phosphor dosimeter by: (a) determining the optimal settings for the optical scanner, (b) measuring 2D proton spot profiles with the storage phosphors, and (c) comparing them to similar measurements using a commercial scintillation detector. METHODS An in-house 2D laboratory optical scanner was constructed and spatially calibrated for accurate 2D photostimulated luminescence (PSL) dosimetry. Square 5 × 5 cm2 BaFBrI:Eu2+ dosimeter samples were uniformly irradiated with line scans performed to determine the physical and electronic scanner settings resulting in the highest signal-to-noise ratios (SNR) at a sub-millimeter spatial resolution. The resultant spatial resolution of the scanner was then quantitatively assessed by measuring (a) line pairs on a standard X-ray lead bar phantom and (b) modulation transfer functions. Following this, 2D proton spot profiles from a Mevion S250i Hyperscan proton unit were obtained at 1, 10, 20, 30, 40, and 50 monitor unit (MU) settings at maximum energy (E0 = 227.1 MeV) and compared to baseline profiles from a commercial scintillation detector, where 1 MU is calibrated to deliver 1 Gy absolute proton dose-to-water under reference conditions, that is, 41 × 41 proton spots uniformly spaced by 0.25 cm within a 10 × 10 cm2 square field size at maximum energy (227.1 MeV) in water at depth of 5 cm at isocenter. The dosimetric system's sensitivities to (a) ±1 mm positional shifts and (b) ±0.3 mm beam lateral spread changes were quantitatively evaluated through a Gaussian fitting of the crossline and inline plots of the respective artificially shifted beam profiles. RESULTS The physical scanner settings of (a) Δτ = 27 ms time interval between data samples, (b) vx = 1.235 cm/s scanning speed, (c) 1% laser transmission (0.02 mW power) and (d) (Δx, Δy) = (0.33, 0.50 mm) pixel sizes with electronic settings of (a) 300 microseconds time constant, (b) normal dynamic reserve, (c) 24 dB/oct low pass filter slope, and (d) 160 Hz chopping frequency resulted in the highest SNR while maintaining sub-millimeter spatial resolution. The BaFBr0.85 I0.15 :Eu2+ storage phosphor dosimeters were linear from 1 to 50 MU and their profiles did not saturate up to 150 MU. The scanner was able to detect lateral displacements of ±1 mm in both the crossline and inline directions and ±0.3 mm beam spread changes that were artificially introduced by varying the incident proton energy. Specific to our proton unit, proton energy changes of ±1 MeV can also be detected indirectly via beam spread measurements. CONCLUSION Our combined dosimetric system including an in-house laboratory optical scanner and reusable BaFBr0.85 I0.15 :Eu2+ storage phosphors demonstrated a sufficient spatial resolution and dosimetric accuracy to support its use as an independent proton spot measurement dosimeter system. Its wide dynamic range allows for other versatile applications such as proton halo measurements.
Collapse
Affiliation(s)
- Jufri Setianegara
- Department of Radiation Oncology, Washington University in St. Louis, St. Louis, Missouri, USA.,Department of Physics, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Thomas R Mazur
- Department of Radiation Oncology, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Yao Hao
- Department of Radiation Oncology, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Deshan Yang
- Department of Radiation Oncology, Washington University in St. Louis, St. Louis, Missouri, USA
| | - H Harold Li
- Department of Radiation Oncology, University of Kansas School of Medicine, Kansas City, Kansas, USA
| |
Collapse
|
8
|
Maruyama S. EXPOSURE DOSE INDEX BASED ON NOISE FACTOR ANALYSIS IN DIGITAL MAMMOGRAPHY: VERIFICATION USING DIRECT-TYPE FLAT-PANEL DETECTOR SYSTEM. RADIATION PROTECTION DOSIMETRY 2020; 192:473-481. [PMID: 33598690 DOI: 10.1093/rpd/ncab003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 12/06/2020] [Accepted: 12/30/2020] [Indexed: 06/12/2023]
Abstract
In this study, the development of a reasonable index of optimized exposure dose is attempted. Using a direct-type flat-panel system, noise factors contained in the image are analyzed based on the relative standard deviation method, and it is verified that the proposed index conforms with the appropriate standards regarding minimum exposure dose. The findings indicate that Poisson noise is dominant in the general clinical dose range; this noise fraction formed 90% of the total noise in the system considered in this study. Considering the results of previous surveys, it is estimated that the point at which the content rate of the Poisson noise starts to decrease can be considered as the lower limit, below which the dose cannot be reduced further without compromising on image quality. As the 'index' obtained by this method can be easily measured, it is useful as a quantitative indicator for dose determination and optimization.
Collapse
Affiliation(s)
- Sho Maruyama
- School of Radiological Sciences, Faculty of Health Science, Gunma Paz University, 3-3-4 Tonyamachi, Takasaki, Gunma 370-0006, Japan
| |
Collapse
|
9
|
Comparison of physical image qualities and artifact indices for head computed tomography in the axial and helical scan modes. Phys Eng Sci Med 2020; 43:557-566. [PMID: 32524440 DOI: 10.1007/s13246-020-00856-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Accepted: 02/28/2020] [Indexed: 01/28/2023]
Abstract
This study aimed to validate the clinically demonstrated equivalency of the axial and helical scan modes (AS and HS, respectively) for head computed tomography (CT) using physical image quality measures and artifact indices (AIs). Two 64-row multi-detector row CT systems (CT-A and CT-B) were used for comparing AS and HSs with detector rows of 64 and 32. The modulation transfer function (MTF), noise power spectrum (NPS), and slice sensitivity profile were measured using a CT dose index corresponding to clinical use. The system performance function (SPF) was calculated as MTF2/NPS. The AI of streak artifacts in the skull base was measured using an image obtained of a head phantom, while the AI of motion artifacts was measured from images obtained during the head phantom was in motion. For CT-A, the 50%MTFs were 7% to 9% higher in the HS than the AS, and the higher MTFs of HS associated NPS increases. For CT-B, the MTFs and NPSs were almost equivalent between the AS and HS, respectively. Consequently, the SPFs of AS and HS were nearly identical for both CT systems. For both CT systems, the skull base AI did not differ significantly between AS and HS, while the motion AIs of HS were significantly better than of AS. The superior motion AI in the HS indicated the effectiveness of HS on moving patients.
Collapse
|
10
|
Kawashima H, Ichikawa K, Takata T, Mitsui W. Algorithm-based artifact reduction in patients with arms-down positioning in computed tomography. Phys Med 2020; 69:61-69. [DOI: 10.1016/j.ejmp.2019.11.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Revised: 11/06/2019] [Accepted: 11/18/2019] [Indexed: 11/25/2022] Open
|
11
|
Marshall NW, Smet M, Hofmans M, Pauwels H, De Clercq T, Bosmans H. Technical characterization of five x-ray detectors for paediatric radiography applications. Phys Med Biol 2017; 62:N573-N586. [PMID: 29064378 DOI: 10.1088/1361-6560/aa9599] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Physical image quality of five x-ray detectors used in the paediatric imaging department is characterized with the aim of establishing the range/scope of imaging performance provided by these detectors for neonatal imaging. Two computed radiography (CR) detectors (MD4.0 powder imaging plate (PIP) and HD5.0 needle imaging plate (NIP), Agfa HealthCare NV, B-2640 Mortsel, Belgium) and three flat panel detectors (FPD) (the Agfa DX-D35C and DX-D45C and the DRX-2530C (Carestream Health Inc., Rochester, NY 14608, USA)) were assessed. Physical image quality was characterized using the detector metrics given by the International Electrotechnical Commission (IEC 62220-1) to measure modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) using the IEC-specified beam qualities of RQA3 and RQA5. The DQE was evaluated at the normal operating detector air kerma (DAK) level, defined at 2.5 µGy for all detectors, and at factors of 1/3.2 and 3.2 times the normal level. MTF curves for the different detectors were similar at both RQA3 and RQA5 energies; the average spatial frequency for the 50% point (MTF0.5) at RQA3 was 1.26 mm-1, with a range from 1.20 mm-1 to 1.37 mm-1. The DQE of the NIP CR compared to the PIP CR was notably greater and similar to that for the FPD devices. At RQA3, average DQE for the FPD and NIP (at 0.5 mm-1; 2.5 µGy) was 0.57 compared to 0.26 for the PIP CR. At the RQA5 energy, the DRX-2530C and the DX-D45C had the highest DQE (~0.6 at 0.5 mm-1; 2.5 µGy). Noise separation analysis using the polynomial model showed higher electronic noise for the DX-D35C and DRX-2530C detectors; this explains the reduced DQE seen at 0.7 µGy/image. The NIP CR detector offers notably improved DQE performance compared to the PIP CR system and a value similar to the DQE for FPD devices at the RQA3 energy.
Collapse
Affiliation(s)
- N W Marshall
- Department of Radiology, UZ Gasthuisberg, Herestraat 49, 3000 Leuven, Belgium. Medical Imaging Research Center, Medical Physics and Quality Assessment, Katholieke Universiteit Leuven, 3000 Leuven, Belgium
| | | | | | | | | | | |
Collapse
|
12
|
An analytical approach to the light transport in columnar phosphors. Detector Optical Gain, angular distribution and the CsI:Tl paradigm. Phys Med 2017; 35:39-49. [PMID: 28242138 DOI: 10.1016/j.ejmp.2017.02.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2016] [Revised: 01/23/2017] [Accepted: 02/11/2017] [Indexed: 11/24/2022] Open
Abstract
PURPOSE An analytical model has been developed for the light propagation in columnar phosphors, based on the optical photon propagation physical and geometrical principles. METHODS This model accounts for the multiple reflections on the sides of the crystal column, as well as for the infinite forward and backward reflections of the propagated optical photon beams created in the crystal bulk. Additionally it considers the lateral propagated optical photon beams after multiple refractions from the neighbor columns and the optical photon attenuation inside the scintillator. The model was used to predict the Detector Optical Gain (DOG), and the angular distribution, of the columnar CsI:Tl scintillators, used in medical imaging. RESULTS The model was validated against CsI:Tl optical photon transmission published results and good agreement was observed. It was, also, found that the DOG is affected by the length of the columns, as well as the incident X-ray energy spectrum. The results of the angular distribution are in accordance with the theory that the longer crystal columns have more directional light distribution. CONCLUSIONS The results of DOG are in accordance with the use of short crystal columns for lower energies (mammography) and the use of long crystal columns for higher energies (general radiology). Angular distribution was found more directive for long crystal columns.
Collapse
|
13
|
Van Peteghem N, Bosmans H, Marshall NW. NPWE model observer as a validated alternative for contrast detail analysis of digital detectors in general radiography. Phys Med Biol 2016; 61:N575-N591. [DOI: 10.1088/0031-9155/61/21/n575] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
14
|
Monnin P, Bosmans H, Verdun FR, Marshall NW. A comprehensive model for quantum noise characterization in digital mammography. Phys Med Biol 2016; 61:2083-108. [PMID: 26895467 DOI: 10.1088/0031-9155/61/5/2083] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A version of cascaded systems analysis was developed specifically with the aim of studying quantum noise propagation in x-ray detectors. Signal and quantum noise propagation was then modelled in four types of x-ray detectors used for digital mammography: four flat panel systems, one computed radiography and one slot-scan silicon wafer based photon counting device. As required inputs to the model, the two dimensional (2D) modulation transfer function (MTF), noise power spectra (NPS) and detective quantum efficiency (DQE) were measured for six mammography systems that utilized these different detectors. A new method to reconstruct anisotropic 2D presampling MTF matrices from 1D radial MTFs measured along different angular directions across the detector is described; an image of a sharp, circular disc was used for this purpose. The effective pixel fill factor for the FP systems was determined from the axial 1D presampling MTFs measured with a square sharp edge along the two orthogonal directions of the pixel lattice. Expectation MTFs were then calculated by averaging the radial MTFs over all possible phases and the 2D EMTF formed with the same reconstruction technique used for the 2D presampling MTF. The quantum NPS was then established by noise decomposition from homogenous images acquired as a function of detector air kerma. This was further decomposed into the correlated and uncorrelated quantum components by fitting the radially averaged quantum NPS with the radially averaged EMTF(2). This whole procedure allowed a detailed analysis of the influence of aliasing, signal and noise decorrelation, x-ray capture efficiency and global secondary gain on NPS and detector DQE. The influence of noise statistics, pixel fill factor and additional electronic and fixed pattern noises on the DQE was also studied. The 2D cascaded model and decompositions performed on the acquired images also enlightened the observed quantum NPS and DQE anisotropy.
Collapse
Affiliation(s)
- P Monnin
- Institute of radiation physics (IRA), Lausanne University Hospital (CHUV), Rue du Grand-Pré 1, 1007 Lausanne, Switzerland. Haute Ecole de Santé Vaud (HESAV), Filière TRM, Avenue de Beaumont 21, 1011 Lausanne, Switzerland
| | | | | | | |
Collapse
|
15
|
Mackenzie A, Dance DR, Diaz O, Young KC. Image simulation and a model of noise power spectra across a range of mammographic beam qualities. Med Phys 2014; 41:121901. [PMID: 25471961 DOI: 10.1118/1.4900819] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2014] [Revised: 08/13/2014] [Accepted: 10/13/2014] [Indexed: 02/11/2024] Open
Abstract
PURPOSE The aim of this work is to create a model to predict the noise power spectra (NPS) for a range of mammographic radiographic factors. The noise model was necessary to degrade images acquired on one system to match the image quality of different systems for a range of beam qualities. METHODS Five detectors and x-ray systems [Hologic Selenia (ASEh), Carestream computed radiography CR900 (CRc), GE Essential (CSI), Carestream NIP (NIPc), and Siemens Inspiration (ASEs)] were characterized for this study. The signal transfer property was measured as the pixel value against absorbed energy per unit area (E) at a reference beam quality of 28 kV, Mo/Mo or 29 kV, W/Rh with 45 mm polymethyl methacrylate (PMMA) at the tube head. The contributions of the three noise sources (electronic, quantum, and structure) to the NPS were calculated by fitting a quadratic at each spatial frequency of the NPS against E. A quantum noise correction factor which was dependent on beam quality was quantified using a set of images acquired over a range of radiographic factors with different thicknesses of PMMA. The noise model was tested for images acquired at 26 kV, Mo/Mo with 20 mm PMMA and 34 kV, Mo/Rh with 70 mm PMMA for three detectors (ASEh, CRc, and CSI) over a range of exposures. The NPS were modeled with and without the noise correction factor and compared with the measured NPS. A previous method for adapting an image to appear as if acquired on a different system was modified to allow the reference beam quality to be different from the beam quality of the image. The method was validated by adapting the ASEh flat field images with two thicknesses of PMMA (20 and 70 mm) to appear with the imaging characteristics of the CSI and CRc systems. RESULTS The quantum noise correction factor rises with higher beam qualities, except for CR systems at high spatial frequencies, where a flat response was found against mean photon energy. This is due to the dominance of secondary quantum noise in CR. The use of the quantum noise correction factor reduced the difference from the model to the real NPS to generally within 4%. The use of the quantum noise correction improved the conversion of ASEh image to CRc image but had no difference for the conversion to CSI images. CONCLUSIONS A practical method for estimating the NPS at any dose and over a range of beam qualities for mammography has been demonstrated. The noise model was incorporated into a methodology for converting an image to appear as if acquired on a different detector. The method can now be extended to work for a wide range of beam qualities and can be applied to the conversion of mammograms.
Collapse
Affiliation(s)
- Alistair Mackenzie
- National Coordinating Centre for the Physics of Mammography, Royal Surrey County Hospital, Guildford GU2 7XX, United Kingdom and Department of Physics, University of Surrey, Guildford GU2 7XH, United Kingdom
| | - David R Dance
- National Coordinating Centre for the Physics of Mammography, Royal Surrey County Hospital, Guildford GU2 7XX, United Kingdom and Department of Physics, University of Surrey, Guildford GU2 7XH, United Kingdom
| | - Oliver Diaz
- Centre for Vision, Speech and Signal Processing, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom and Computer Vision and Robotics Research Institute, University of Girona, Girona 17071, Spain
| | - Kenneth C Young
- National Coordinating Centre for the Physics of Mammography, Royal Surrey County Hospital, Guildford GU2 7XX, United Kingdom and Department of Physics, University of Surrey, Guildford GU2 7XH, United Kingdom
| |
Collapse
|
16
|
Monnin P, Bosmans H, Verdun FR, Marshall NW. Comparison of the polynomial model against explicit measurements of noise components for different mammography systems. Phys Med Biol 2014; 59:5741-61. [DOI: 10.1088/0031-9155/59/19/5741] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
17
|
Salvagnini E, Bosmans H, Struelens L, Marshall NW. Effective detective quantum efficiency for two mammography systems: measurement and comparison against established metrics. Med Phys 2014; 40:101916. [PMID: 24089918 DOI: 10.1118/1.4820362] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Abstract
PURPOSE The aim of this paper was to illustrate the value of the new metric effective detective quantum efficiency (eDQE) in relation to more established measures in the optimization process of two digital mammography systems. The following metrics were included for comparison against eDQE: detective quantum efficiency (DQE) of the detector, signal difference to noise ratio (SdNR), and detectability index (d') calculated using a standard nonprewhitened observer with eye filter. METHODS The two systems investigated were the Siemens MAMMOMAT Inspiration and the Hologic Selenia Dimensions. The presampling modulation transfer function (MTF) required for the eDQE was measured using two geometries: a geometry containing scattered radiation and a low scatter geometry. The eDQE, SdNR, and d' were measured for poly(methyl methacrylate) (PMMA) thicknesses of 20, 40, 60, and 70 mm, with and without the antiscatter grid and for a selection of clinically relevant target/filter (T/F) combinations. Figures of merit (FOMs) were then formed from SdNR and d' using the mean glandular dose as the factor to express detriment. Detector DQE was measured at energies covering the range of typical clinically used spectra. RESULTS The MTF measured in the presence of scattered radiation showed a large drop at low spatial frequency compared to the low scatter method and led to a corresponding reduction in eDQE. The eDQE for the Siemens system at 1 mm(-1) ranged between 0.15 and 0.27, depending on T/F and grid setting. For the Hologic system, eDQE at 1 mm(-1) varied from 0.15 to 0.32, again depending on T/F and grid setting. The eDQE results for both systems showed that the grid increased the system efficiency for PMMA thicknesses of 40 mm and above but showed only small sensitivity to T/F setting. While results of the SdNR and d' based FOMs confirmed the eDQE grid position results, they were also more specific in terms of T/F selection. For the Siemens system at 20 mm PMMA, the FOMs indicated Mo/Mo (grid out) as optimal while W/Rh (grid in) was the optimal configuration at 40, 60, and 70 mm PMMA. For the Hologic, the FOMs pointed to W/Rh (grid in) at 20 and 40 mm of PMMA while W/Ag (grid in) gave the highest FOM at 60 and 70 mm PMMA. Finally, DQE at 1 mm(-1) averaged for the four beam qualities studied was 0.44 ± 0.02 and 0.55 ± 0.03 for the Siemens and Hologic detectors, respectively, indicating only a small influence of energy on detector DQE. CONCLUSIONS Both the DQE and eDQE data showed only a small sensitivity to T/F setting for these two systems. The eDQE showed clear preferences in terms of scatter reduction, being highest for the grid-in geometry for PMMA thicknesses of 40 mm and above. The SdNR and d' based figures of merit, which contain additional weighting for contrast and dose, pointed to specific T/F settings for both systems.
Collapse
Affiliation(s)
- Elena Salvagnini
- UZ Gasthuisberg, Medical Imaging Research Center and Department of Radiology, Herestraat 49, B-3000 Leuven, Belgium and SCK●CEN, Boeretang 200, B-2400 Mol, Belgium
| | | | | | | |
Collapse
|
18
|
Moore CS, Wood TJ, Avery G, Balcam S, Needler L, Beavis AW, Saunderson JR. An investigation of automatic exposure control calibration for chest imaging with a computed radiography system. Phys Med Biol 2014; 59:2307-24. [DOI: 10.1088/0031-9155/59/9/2307] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
19
|
Rivetti S, Lanconelli N, Bertolini M, Nitrosi A, Burani A. Characterization of a clinical unit for digital radiography based on irradiation side sampling technology. Med Phys 2013; 40:101902. [DOI: 10.1118/1.4820364] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
|
20
|
Hansel RA, Xiao Z, Hu Y, Green O, Yang D, Harold Li H. The role of activator concentration and precipitate formation on optical and dosimetric properties of KCl:Eu(2+) storage phosphor detectors. Med Phys 2013; 40:092104. [PMID: 24007173 DOI: 10.1118/1.4817522] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The activator ion (Eu(2+) in KCl:Eu(2+)) plays an important role in the photostimulated luminescence (PSL) mechanism of storage phosphor radiation detectors. In order to design an accurate, effective, and robust detector, it is important to understand how the activator ion concentration affects the structure and, consequently, radiation detection properties of KCl:Eu(2+). METHODS Potassium chloride pellets were fabricated with various amounts of europium dopant (0.01-5.0 mol.% Eu(2+)). Clinical radiation doses were given with a 6 MV linear accelerator. Radiation doses larger than 100 Gy were given with a (137)Cs irradiator. Dose response curves, radiation hardness, and temporal signal stability were measured using a laboratory PSL readout system. The crystal structure of the material was studied using x ray diffraction and luminescence spectroscopy. RESULTS The most intense PSL signal was from samples with 1.0 mol.% Eu. However, samples with concentrations higher than 0.05 mol.% Eu exhibited significant degradation in PSL intensity for cumulated doses larger than 3000 Gy. Structural and luminescence spectroscopy showed clear evidence of precipitate phases within the KCl lattice, especially for high activator concentrations. Analysis of PL emission spectra showed that interactions between Eu-Vc dipoles and Eu-Vc trimers could explain trends in PSL sensitivity and radiation hardness observations. CONCLUSIONS The concentration of the activator ion (Eu(2+)) significantly affects radiation detection properties of the storage phosphor KCl:Eu(2+). An activator concentration between 0.01 and 0.05 mol.% Eu in KCl:Eu(2+) storage phosphor detectors is recommended for linear dose response, good PSL sensitivity, predictable temporal stability, and high reusability for megavoltage radiation detection.
Collapse
Affiliation(s)
- Rachael A Hansel
- Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110, USA
| | | | | | | | | | | |
Collapse
|
21
|
Marshall NW, Lemmens K, Bosmans H. Physical evaluation of a needle photostimulable phosphor based CR mammography system. Med Phys 2012; 39:811-24. [PMID: 22320791 DOI: 10.1118/1.3675403] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
PURPOSE Needle phosphor based computed radiography (CR) systems promise improved image quality compared to powder phosphor based CR units for x-ray screening mammography. This paper compares the imaging performance of needle CR cassettes, powder based CR cassettes and a well established amorphous selenium (a-Se) based flat panel based mammography system, using consistent beam qualities. METHODS Detector performance was assessed using modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE). Mammography system performance was assessed against levels from the European Guidelines, including threshold gold thickness (c-d), relative signal difference to noise (SdNR) and mean glandular dose, for automatic exposure control settings suggested by the manufacturers. The needle based Agfa HM5.0 CR detector was compared against the single sided readout Agfa MM3.0R and dual sided readout Fuji Profect CS powder CR plates using a 28 kV Mo/Rh spectrum, while a 28 kV W/Rh spectrum was used to compare the Agfa HM5.0 against the Siemens MAMMOMAT Inspiration a-Se based system. RESULTS MTF at 5 mm(-1) was 0.16 and 0.24 for the needle CR detector in the fast and slow scan directions, respectively, indicating a slight improvement (∼20%) over the two powder CR systems but remained 50% lower than the result at 5 mm(-1) for the a-Se detector (∼0.55). Structured screen noise was lower for the needle phosphor compared to the powder plates. CR system gain, estimated from the measured absorption fraction and NNPS results, was 6.3 for the (single sided) needle phosphor and 5.1 and 7.2 for the single sided and dual sided powder phosphor systems. Peak DQE at ∼100 μGy was 0.47 for the needle system compared to peak DQE figures of 0.33 and 0.46 for the single sided readout powder plates and dual sided readout plates. The high frequency DQE (at 5 mm(-1)) was 0.19 for the needle CR plates, a factor of approximately 3 greater than for the powder CR plates. At 28 kV W/Rh, 2 mm Al, peak DQE for the needle CR system was 0.45 against a value of 0.50 for the a-Se detector. The needle CR detector reached the Acceptable limit for 0.1 mm details in the European Guidelines at a mean glandular dose (MGD) of approximately 1.31 mGy imaged at 28 kV Mo/Rh, compared to figures of 2.19 and 1.43 mGy for the single sided and dual sided readout powder CR systems. The a-Se detector could reach the limit at 0.65 mGy using a 28 kV W/Rh spectrum, while the needle CR system required 1.09 mGy for the same spectrum. CONCLUSIONS Imaging performance for the needle CR phosphor technology, characterized using MTF and DQE and threshold gold thickness demonstrated a clear improvement compared to both single and dual sided reading powder phosphor based CR systems.
Collapse
|
22
|
Mackenzie A, Dance DR, Workman A, Yip M, Wells K, Young KC. Conversion of mammographic images to appear with the noise and sharpness characteristics of a different detector and x-ray system. Med Phys 2012; 39:2721-34. [DOI: 10.1118/1.4704525] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
23
|
Kunitomo H, Ichikawa K, Higashide R, Ohashi K. [Physical image properties of digital radiography systems in low dose range]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2012; 68:961-969. [PMID: 22975694 DOI: 10.6009/jjrt.2012_jsrt_68.8.961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We measured physical image properties of a flat panel detector (FPD) system and a computed radiography (CR) system, targeting to a low dose range (reference dose: 2.58×10(-7) C/kg: to 1/20 dose). Input-output properties, pre-sampled modulation transfer functions (pre-sampled MTFs), and normalized noise power spectra for an FPD system equipped with a CsI scintillator (FPDcsi) and a CR system with an imaging plate coated with storage phosphor (CR) were measured at the low dose range for radiation quality of RQA3 (≍50 skV) and RQA5 (≍70 kV), and detective quantum efficiencies (DQEs) were calculated. In addition, in order to validate the DQE results, component fractions of Poisson and multiplicative and additive noise were analyzed using relative standard deviation analysis. The DQE values of FPDcsi were decreased with dose decrease, and contrarily to these, those of CR were increased. At the 1/10 and 1/20 doses for RQA3, the DQEs of FPDcsi and CR became almost the same. From the results of RSD analysis, it was proved that the main cause of DQE deterioration on FPDcsi are non-negligible additive (electronic) noise, and the DQE improvement on CR was caused by both of significant multiplicative (structure) noise and very low electronic noise. The DQE results were validated by comparing burger phantom images of each dose and radiation quality.
Collapse
Affiliation(s)
- Hiroshi Kunitomo
- Department of Central Radiological Technology, Nagoya City University Hospital
| | | | | | | |
Collapse
|
24
|
Feasibility of dose reduction using needle-structured image plates versus powder-structured plates for computed radiography of the knee. AJR Am J Roentgenol 2011; 197:W318-23. [PMID: 21785059 DOI: 10.2214/ajr.10.5505] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
OBJECTIVE A newly developed computed radiography (CR) detector that uses a storage phosphor plate made of needle-shaped crystals provides improved dose efficiency. The aim of our study was to compare the image quality of standard-dose CR and dose-reduced CR achieved using needle technology for knee imaging in a clinical setting. MATERIALS AND METHODS We compared standard CR images obtained using a powder-structured image plate (PIP) (ADC Compact Plus) with images obtained using the new needle-structured image plate (NIP) (DX-S). In 30 consecutive patients with knee pain willing to participate in this study, anteroposterior knee radiographs were acquired with both systems at a standard dose. In addition, NIP images were obtained with approximately 75% and 50% of the standard dose (corresponding incident doses: 300, 235, and 154 μGy, respectively). Images were evaluated in a blinded, side-by-side comparison. Six radiologists determined whether there was an appreciable difference in image quality at five anatomic landmarks in regions with high and low differences of attenuation. They also assessed the delineation of selected abnormalities and ranked them using a 10-point scale. The rating scores were tested for statistical differences using an analysis of variance with repeated measures. RESULTS The mean overall rating scores for the evaluation of anatomic landmarks were 6.97 for NIP images obtained at full dose, 6.48 for NIP images obtained at about 75% dose, 5.47 for NIP images obtained at half dose, and 6.01 for PIP images. There was a significant difference in favor of the CR system with an NIP at the same dose level (p < 0.05). The NIP images obtained at a dose of about 75% were also ranked significantly better than the PIP images with regard to the depiction of both anatomic landmarks and abnormalities. The readers ranked half-dose NIP images inferior to the PIP images with regard to abnormalities and anatomic landmarks in areas with high attenuation, whereas in areas with low attenuation, the image quality was regarded as equivalent to the standard technique. CONCLUSION NIP technology allows a dose reduction of approximately 25% compared with PIP while still providing higher image quality. Even at the half-dose level, there was no relevant loss of image quality with regard to the delineation of anatomic landmarks in areas with low attenuation in anteroposterior knee images. The higher dose efficiency of the needle-detector CR technology compared with conventional CR can be used either for dose reduction or for improved image quality.
Collapse
|
25
|
Berger-Kulemann V, Pötter-Lang S, Gruber M, Berger R, Vonbank K, Weber M, Rabitsch W, Uffmann M. Needle image plates compared to conventional CR in chest radiography: is dose reduction possible? Eur J Radiol 2011; 81:4156-60. [PMID: 21798682 DOI: 10.1016/j.ejrad.2011.06.060] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2011] [Accepted: 06/16/2011] [Indexed: 11/24/2022]
Abstract
PURPOSE To compare image quality of standard-dose computed radiography and dose reduced needle-technology CR for supine CXR in a clinical setting. MATERIALS AND METHODS We prospectively evaluated 128 radiographs of 32 immunocompromised patients. For each patient four clinical CXR were performed within one week, two with powder image plates (PIP; Fuji ST-V) and two with needle image plates (NIP; Agfa DXS) at standard and half dose, respectively. One experienced radiologist and two residents blinded to dose level and kind of imaging system rated different anatomical structures, image noise, tubes/lines and abnormalities on a image quality scale from 1 to 10 (1=poor, 10=excellent). The rating scores were tested for statistical differences using analysis of variance with repeated measures. RESULTS A statistical difference (p<0.05) was found for the two systems as well as for the two dose levels. Overall rating scores were 6.5 for PIP with full dose, 6.2 for PIP with half dose, 7.6 for NIP with full dose and 7.4 for NIP with half dose. There was a significant difference in favour of the NIP system at the same dose level. Also the NIP images obtained at half dose were ranked significantly better compared to the PIP images at standard dose. The differences in ranking of anatomical structures and abnormalities were more pronounced in low absorption areas (pulmonary vessels, parenchyma) than in high absorption areas (mediastinum, spine). CONCLUSION For supine chest radiograms the NIP technology allows for a dose reduction of 50% while providing higher image quality.
Collapse
Affiliation(s)
- Vanessa Berger-Kulemann
- Department of Radiology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Rivetti S, Lanconelli N, Bertolini M, Acchiappati D. A new clinical unit for digital radiography based on a thick amorphous Selenium plate: Physical and psychophysical characterization. Med Phys 2011; 38:4480-8. [DOI: 10.1118/1.3605471] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
27
|
Marshall NW, Monnin P, Bosmans H, Bochud FO, Verdun FR. Image quality assessment in digital mammography: part I. Technical characterization of the systems. Phys Med Biol 2011; 56:4201-20. [DOI: 10.1088/0031-9155/56/14/002] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
28
|
Leblans P, Vandenbroucke D, Willems P. Storage Phosphors for Medical Imaging. MATERIALS (BASEL, SWITZERLAND) 2011; 4:1034-1086. [PMID: 28879966 PMCID: PMC5448636 DOI: 10.3390/ma4061034] [Citation(s) in RCA: 117] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2011] [Revised: 05/30/2011] [Accepted: 06/07/2011] [Indexed: 11/20/2022]
Abstract
Computed radiography (CR) uses storage phosphor imaging plates for digital imaging. Absorbed X-ray energy is stored in crystal defects. In read-out the energy is set free as blue photons upon optical stimulation. In the 35 years of CR history, several storage phosphor families were investigated and developed. An explanation is given as to why some materials made it to the commercial stage, while others did not. The photo stimulated luminescence mechanism of the current commercial storage phosphors, BaFBr:Eu2+ and CsBr:Eu2+ is discussed. The relation between storage phosphor plate physical characteristics and image quality is explained. It is demonstrated that the morphology of the phosphor crystals in the CR imaging plate has a very significant impact on its performance.
Collapse
Affiliation(s)
- Paul Leblans
- Agfa HealthCare NV, Septestraat 27, B-2640 Mortsel, Belgium.
| | | | - Peter Willems
- Industrial Scientific and Computing BVBA, Hellestraat 55, B-9190 Stekene, Belgium.
| |
Collapse
|
29
|
Kuhls-Gilcrist A, Jain A, Bednarek DR, Rudin S. Measuring the presampled MTF from a reduced number of flat-field images using the Noise Response (NR) method. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2011; 7961. [PMID: 21731401 DOI: 10.1117/12.877890] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
We evaluate a new method for measuring the presampled modulation transfer function (MTF) using the noise power spectrum (NPS) obtained from a few flat-field images acquired at one exposure level. The NPS is the sum of structure, quantum, and additive instrumentation noise, which are proportional to exposure squared, exposure, and a constant, respectively, with the spatial-frequency dependence of the quantum noise depending partly on the detector MTF. Cascaded linear-systems theory was used to derive an exact and generic relationship that was used to isolate noise terms and enable determination of the MTF directly from the noise response, thereby circumventing the need for precision test objects (slit, edge, etc.) as required by standard techniques. Isolation of the quantum NPS by fitting the total NPS versus exposure obtained using 30 flat-field images each at six or more different exposure levels with a linear regression provides highly accurate MTFs. A subset of these images from indirect digital detectors was used to investigate the accuracy of measuring the MTF from 30 or fewer flat-field images obtained at a single exposure level. Analyzing as few as two images acquired at a single exposure resulted in no observable systematic error. Increasing the number of images analyzed resulted in an increase in accuracy. Fifteen images provided comparable accuracy with the most rigorous slope approach, with less than 5% variability, suggesting additional image acquisitions may be unnecessary. Reducing the number of images acquired for the noise response method further simplifies and facilitates routine MTF measurements.
Collapse
|
30
|
Marshall NW, Mackenzie A, Honey ID. Quality control measurements for digital x-ray detectors. Phys Med Biol 2011; 56:979-99. [PMID: 21248386 DOI: 10.1088/0031-9155/56/4/007] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This paper describes a digital radiography (DR) quality control protocol for DR detectors from the forthcoming report from the Institute of Physics and Engineering in Medicine (IPEM). The protocol was applied to a group of six identical caesium iodide (CsI) digital x-ray detectors to assess reproducibility of methods, while four further detectors were assessed to examine the wider applicability. Twelve images with minimal spatial frequency processing are required, from which the detector response, lag, modulation transfer function (MTF), normalized noise power spectrum (NNPS) and threshold contrast-detail (c-d) detectability are calculated. The x-ray spectrum used was 70 kV and 1 mm added copper filtration, with a target detector air kerma of 2.5 µGy for the NNPS and c-d results. In order to compare detector performance with previous imaging technology, c-d data from four screen/film systems were also acquired, at a target optical density of 1.5 and an average detector air kerma of 2.56 µGy. The DR detector images were typically acquired in 20 min, with a further 45 min required for image transfer and analysis. The average spatial frequency for the 50% point of the MTF for six identical detectors was 1.29 mm(-1) ± 0.05 (3.9% coefficient of variation (cov)). The air kerma set for the six systems was 2.57 µGy ± 0.13 (5.0% cov) and the NNPS at this air kerma was 1.42 × 10(-5) mm(2) (6.5% cov). The detective quantum efficiency (DQE) measured for the six identical detectors was 0.60 at 0.5 mm(-1), with a maximum cov of 10% at 2.9 mm(-1), while the average DQE was 0.56 at 0.5 mm(-1) for three CsI detectors from three different manufacturers. Comparable c-d performance was found for these detectors (5.9% cov) with an average threshold contrast of 0.46% for 11 mm circular discs. The average threshold contrast for the S/F systems was 0.70% at 11 mm, indicating superior imaging performance for the digital systems. The protocol was found to be quick, reproducible and gave an in-depth assessment of performance for a range of digital x-ray detectors.
Collapse
Affiliation(s)
- N W Marshall
- Department of Radiology, University Hospitals Leuven, Leuven, Belgium.
| | | | | |
Collapse
|
31
|
Ichikawa K. [Fundamentals of relationship between physical image quality and radiation dose in digital radiography]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2011; 67:1473-1477. [PMID: 22104242 DOI: 10.6009/jjrt.67.1473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
|
32
|
Kuhls-Gilcrist A, Bednarek DR, Rudin S. A method for the determination of the two-dimensional MTF of digital radiography systems using only the noise response. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2010; 7622:76224W-76244W9. [PMID: 21170177 DOI: 10.1117/12.843918] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
We present a new method that enables the determination of the two-dimensional MTF of digital radiography systems using the noise response measured from flat-field images. Unlike commonly-used methods that measure the one-dimensional MTF, this new method does not require precision-made test-objects (slits/edges) or precise tool alignment. Although standard methods are dependent upon data processing that can result in inaccuracies and inconsistencies, this method based on the intrinsic noise response of the imager is highly accurate and less susceptible to such problems. A cascaded-linear-systems analysis was used to derive an exact relationship between the noise power spectrum (NPS) and the presampled MTF of a generalized detector system. The NPS was then used to determine the two-dimensional MTF for three systems: a simulated detector in which the "true" MTF was known exactly, a commercial indirect flat-panel detector (FPD), and a new solid-state x-ray image intensifier (SSXII). For the simulated detector, excellent agreement was observed between the "true" MTF and that determined using the noise response method, with an averaged deviation of 0.3%. The FPD MTF was shown to increase on the diagonals and was measured at 2.5 cycles/mm to be 0.086±0.007, 0.12±0.01, and 0.087±0.007 at 0, 45, and 90°, respectively. No statistically significant variation was observed for the SSXII as a function of angle. Measuring the two-dimensional MTF should lead to more accurate characterization of the detector resolution response, incorporating any potential non-isotropy which may result from the physical characteristics of the sensor, including the active-area shape of the pixel array.
Collapse
Affiliation(s)
- Andrew Kuhls-Gilcrist
- University at Buffalo (State University of New York), Toshiba Stroke Research Center, 3435 Main St., Buffalo, NY USA 14214
| | | | | |
Collapse
|
33
|
Vedantham S, Karellas A. Modeling the performance characteristics of computed radiography (CR) systems. IEEE TRANSACTIONS ON MEDICAL IMAGING 2010; 29:790-806. [PMID: 20199915 PMCID: PMC5228607 DOI: 10.1109/tmi.2009.2036995] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Computed radiography (CR) using storage phosphors is widely used in digital radiography and mammography. A cascaded linear systems approach wherein several parameter values were estimated using Monte Carlo methods was used to model the image formation process of a single-side read ;;flying spot'' CR system using a granular phosphor. Objective image quality metrics such as modulation transfer function and detective quantum efficiency were determined using this model and show good agreement with published empirical data. A model such as that addressed in this work could allow for improved understanding of the effect of storage phosphor physical properties and CR reader parameters on objective image quality metrics for existing and evolving CR systems.
Collapse
Affiliation(s)
- Srinivasan Vedantham
- Department of Radiology, University of Massachusetts Medical School, Worcester, MA 01655, USA.
| | | |
Collapse
|
34
|
Kuhls-Gilcrist A, Jain A, Bednarek DR, Hoffmann KR, Rudin S. Accurate MTF measurement in digital radiography using noise response. Med Phys 2010; 37:724-35. [PMID: 20229882 PMCID: PMC2821422 DOI: 10.1118/1.3284376] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2009] [Revised: 09/26/2009] [Accepted: 12/08/2009] [Indexed: 12/13/2022] Open
Abstract
PURPOSE The authors describe a new technique to determine the system presampled modulation transfer function (MTF) in digital radiography using only the detector noise response. METHODS A cascaded-linear systems analysis was used to develop an exact relationship between the two-dimensional noise power spectrum (NPS) and the presampled MTF for a generalized detector system. This relationship was then utilized to determine the two-dimensional presampled MTF. For simplicity, aliasing of the correlated noise component of the NPS was assumed to be negligible. Accuracy of this method was investigated using simulated images from a simple detector model in which the "true" MTF was known exactly. Measurements were also performed on three detector technologies (an x-ray image intensifier, an indirect flat panel detector, and a solid state x-ray image intensifier), and the results were compared using the standard edge-response method. Flat-field and edge images were acquired and analyzed according to guidelines set forth by the International Electrotechnical Commission, using the RQA 5 spectrum. RESULTS The presampled MTF determined using the noise-response method for the simulated detector system was in close agreement with the true MTF with an averaged percent difference of 0.3% and a maximum difference of 1.1% observed at the Nyquist frequency (fN). The edge-response method of the simulated detector system also showed very good agreement at lower spatial frequencies (less than 0.5 fN) with an averaged percent difference of 1.6% but showed significant discrepancies at higher spatial frequencies (greater than 0.5 fN) with an averaged percent difference of 17%. Discrepancies were in part a result of noise in the edge image and phasing errors. For all three detector systems, the MTFs obtained using the two methods were found to be in good agreement at spatial frequencies less than 0.5 fN with an averaged percent difference of 3.4%. Above 0.5 fN, differences increased to an average of 20%. Deviations of the experimental results largely followed the trend seen in the simulation results, suggesting that differences between the two methods could be explained as resulting from the inherent inaccuracies of the edge-response measurement technique used in this study. Aliasing of the correlated noise component was shown to have a minimal effect on the measured MTF for the three detectors studied. Systems with significant aliasing of the correlated noise component (e.g., a-Se based detectors) would likely require a more sophisticated fitting scheme to provide accurate results. CONCLUSIONS Results indicate that the noise-response method, a simple technique, can be used to accurately measure the MTF of digital x-ray detectors, while alleviating the problems and inaccuracies associated with use of precision test objects, such as a slit or an edge.
Collapse
Affiliation(s)
- Andrew Kuhls-Gilcrist
- Toshiba Stroke Research Center University at Buffalo, State University of New York, Biomedical Research Building, Room 445, 3435 Main Street, Buffalo, New York 14214, USA.
| | | | | | | | | |
Collapse
|
35
|
Rivetti S, Lanconelli N, Bertolini M, Nitrosi A, Burani A, Acchiappati D. Comparison of different computed radiography systems: Physical characterization and contrast detail analysis. Med Phys 2010; 37:440-8. [DOI: 10.1118/1.3284539] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
36
|
Rivetti S, Lanconelli N, Bertolini M, Borasi G, Golinelli P, Acchiappati D, Gallo E. Physical and psychophysical characterization of a novel clinical system for digital mammography. Med Phys 2009; 36:5139-48. [DOI: 10.1118/1.3245879] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
|
37
|
Marshall NW. An examination of automatic exposure control regimes for two digital radiography systems. Phys Med Biol 2009; 54:4645-70. [DOI: 10.1088/0031-9155/54/15/002] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
38
|
Marshall NW. Detective quantum efficiency measured as a function of energy for two full-field digital mammography systems. Phys Med Biol 2009; 54:2845-61. [DOI: 10.1088/0031-9155/54/9/017] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
39
|
Moore CS, Saunderson JR, Beavis AW. Investigating the exposure class of a computed radiography system for optimisation of physical image quality for chest radiography. Br J Radiol 2009; 82:705-10. [PMID: 19221185 DOI: 10.1259/bjr/27942950] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The purpose of this study was to investigate whether the exposure (speed) class (EC) of an Agfa computed radiography (CR) system could be used to optimise chest radiography. The frequency-dependent normalised noise-power spectra (NNPS(f)) were determined for a range of EC settings (25-1200) for a receptor dose of 4 microGy. Signal-to-noise ratios (SNRs) were measured in the lung, heart and diaphragm areas of a chest phantom with ECs of 400 and 600 at four tube voltages (60, 75, 90 and 125 kVp). As anatomical background can be a factor in detection of lung nodules, a tissue to rib ratio (TRR), which measures the ratio of pixel values in the nodule to that of rib, was measured in the lung region of the phantom to assess the suppression of the rib at ECs of 400 and 600. The NNPS(f) at ECs lower than 400 was relatively high. The NNPS(f) at EC 600 was found to be 7% lower when averaged over all frequencies than that at EC 400. The statistical significance of this difference was verified. The EC 800 and EC 1200 settings offered no extra advantages in terms of lowering frequency-dependent noise. The EC 600 setting offered improvements in SNR of between 10% and 18% in the lung, 11% and 16% in the heart, and 15% and 20% in the diaphragm compared with EC 400. Statistical analysis verified the significant difference. The EC 600 setting increased the TRR, thereby helping to suppress rib. This work indicates that an exposure class setting of 600 is the most appropriate for standard chest radiography, but clinical verification is required.
Collapse
Affiliation(s)
- C S Moore
- Radiation Physics Department, Hull and East Yorkshire Hospitals, Oncology Centre, Castle Hill Hospital, Cottingham, East Yorkshire.
| | | | | |
Collapse
|
40
|
Kuhls-Gilcrist A, Bednarek DR, Rudin S. Component analysis of a new Solid State X-ray Image Intensifier (SSXII) using photon transfer and Instrumentation Noise Equivalent Exposure (INEE) measurements. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2009; 7258:7258171-72581710. [PMID: 19763251 PMCID: PMC2745170 DOI: 10.1117/12.813957] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
The SSXII is a novel x-ray imager designed to improve upon the performance limitations of conventional dynamic radiographic/fluoroscopic imagers related to resolution, charge-trapping, frame-rate, and instrumentation-noise. The SSXII consists of a CsI:Tl phosphor coupled via a fiber-optic taper (FOT) to an electron-multiplying CCD (EMCCD). To facilitate investigational studies, initial designs enable interchangeability of such imaging components. Measurements of various component and configuration characteristics enable an optimization analysis with respect to overall detector performance. Photon transfer was used to characterize the EMCCD performance including ADC sensitivity, read-noise, full-well capacity and quantum efficiency. X-ray sensitivity was measured using RQA x-ray spectra. Imaging components were analyzed in terms of their MTF and transmission efficiency. The EMCCD was measured to have a very low effective read-noise of less than 1 electron rms at modest EMCCD gains, which is more than two orders-of-magnitude less than flat panel (FPD) and CMOS-based detectors. The variable signal amplification from 1 to 2000 times enables selectable sensitivities ranging from 8.5 (168) to over 15k (300k) electrons per incident x-ray photon with (without) a 4:1 FOT; these sensitivities could be readily increased with further component optimization. MTF and DQE measurements indicate the SSXII performance is comparable to current state-of-the-art detectors at low spatial frequencies and far exceeds them at higher spatial frequencies. The instrumentation noise equivalent exposure (INEE) was measured to be less than 0.3 μR out to 10 cycles/mm, which is substantially better than FPDs. Component analysis suggests that these improvements can be substantially increased with further detector optimization.
Collapse
Affiliation(s)
- Andrew Kuhls-Gilcrist
- University at Buffalo (State University of New York), Toshiba Stroke Research Center, 3435 Main St., Buffalo, NY USA 14214
| | - Daniel R. Bednarek
- University at Buffalo (State University of New York), Toshiba Stroke Research Center, 3435 Main St., Buffalo, NY USA 14214
| | - Stephen Rudin
- University at Buffalo (State University of New York), Toshiba Stroke Research Center, 3435 Main St., Buffalo, NY USA 14214
| |
Collapse
|
41
|
Samei E, Ranger NT, MacKenzie A, Honey ID, Dobbins JT, Ravin CE. Detector or system? Extending the concept of detective quantum efficiency to characterize the performance of digital radiographic imaging systems. Radiology 2008; 249:926-37. [PMID: 19011189 PMCID: PMC2691810 DOI: 10.1148/radiol.2492071734] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To develop an experimental method for measuring the effective detective quantum efficiency (eDQE) of digital radiographic imaging systems and evaluate its use in select imaging systems. MATERIALS AND METHODS A geometric phantom emulating the attenuation and scatter properties of the adult human thorax was employed to assess eight imaging systems in a total of nine configurations. The noise power spectrum (NPS) was derived from images of the phantom acquired at three exposure levels spanning the operating range of the system. The modulation transfer function (MTF) was measured by using an edge device positioned at the anterior surface of the phantom. Scatter measurements were made by using a beam-stop technique. All measurements, including those of phantom attenuation and estimates of x-ray flux, were used to compute the eDQE. RESULTS The MTF results showed notable degradation owing to focal spot blur. Scatter fractions ranged between 11% and 56%, depending on the system. The eDQE(0) results ranged from 1%-17%, indicating a reduction of up to one order of magnitude and different rank ordering and performance among systems, compared with that implied in reported conventional detective quantum efficiency results from the same systems. CONCLUSION The eDQE method was easy to implement, yielded reproducible results, and provided a meaningful reflection of system performance by quantifying image quality in a clinically relevant context. The difference in the magnitude of the measured eDQE and the ideal eDQE of 100% provides a great opportunity for improving the image quality of radiographic and mammographic systems while reducing patient dose.
Collapse
Affiliation(s)
- Ehsan Samei
- Duke Advanced Imaging Laboratories, Department of Radiology, Duke University and Medical Center, 2424 Erwin Rd, Suite 302, Durham, NC 27705, USA
| | | | | | | | | | | |
Collapse
|
42
|
Honey ID, Mackenzie A. Artifacts found during quality assurance testing of computed radiography and digital radiography detectors. J Digit Imaging 2008; 22:383-92. [PMID: 18427900 DOI: 10.1007/s10278-008-9109-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2007] [Revised: 01/06/2008] [Accepted: 02/07/2008] [Indexed: 10/22/2022] Open
Abstract
A series of artifact images, obtained over 5 years of performance testing, of both computed radiography (CR) and integrated digital radiographic X-ray imaging detectors are presented. The images presented are all either flat field or test object images and show artifacts previously either undescribed in the existing literature or meriting further comment. The artifacts described are caused by incorrect flat field corrections, a failing amplifier, damaged detector lines affecting their neighbors, lost information between neighboring detector tiles, image retention, delamination of a detector, poor setup of mechanical movements in CR, suckers damaging a CR plate, inappropriate use of grid suppression software, inappropriate use of a low pass spatial frequency filter, and unsharp masking filters. The causes and significance of the artifacts are explained and categorized as software or hardware related. Actions taken to correct the artifacts are described and explained. This work will help physicists, radiographers, and radiologists identify various image quality problems and shows that quality assurance is useful in identifying artifacts.
Collapse
Affiliation(s)
- Ian D Honey
- Medical Physics and Bioengineering Department, Christchurch Hospital, Private Bag 4710, Christchurch 8140, New Zealand.
| | | |
Collapse
|