1
|
Cicero NG, Fultz NE, Jeong H, Williams SD, Gomez D, Setzer B, Warbrick T, Jaschke M, Gupta R, Lev M, Bonmassar G, Lewis LD. High-quality multimodal MRI with simultaneous EEG using conductive ink and polymer-thick film nets. J Neural Eng 2024; 21:066004. [PMID: 39419105 DOI: 10.1088/1741-2552/ad8837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Accepted: 10/17/2024] [Indexed: 10/19/2024]
Abstract
Objective. Combining magnetic resonance imaging (MRI) and electroencephalography (EEG) provides a powerful tool for investigating brain function at varying spatial and temporal scales. Simultaneous acquisition of both modalities can provide unique information that a single modality alone cannot reveal. However, current simultaneous EEG-fMRI studies are limited to a small set of MRI sequences due to the image quality and safety limitations of commercially available MR-conditional EEG nets. We tested whether the Inknet2, a high-resistance polymer thick film based EEG net that uses conductive ink, could enable the acquisition of a variety of MR image modalities with minimal artifacts by reducing the radiofrequency-shielding caused by traditional MR-conditional nets.Approach. We first performed simulations to model the effect of the EEG nets on the magnetic field and image quality. We then performed phantom scans to test image quality with a conventional copper EEG net, with the new Inknet2, and without any EEG net. Finally, we scanned five human subjects at 3 Tesla (3 T) and three human subjects at 7 Tesla (7 T) with and without the Inknet2 to assess structural and functional MRI image quality.Main results. Across these simulations, phantom scans, and human studies, the Inknet2 induced fewer artifacts than the conventional net and produced image quality similar to scans with no net present.Significance. Our results demonstrate that high-quality structural and functional multimodal imaging across a variety of MRI pulse sequences at both 3 T and 7 T is achievable with an EEG net made with conductive ink and polymer thick film technology.
Collapse
Affiliation(s)
- Nicholas G Cicero
- Graduate Program in Neuroscience, Boston University, Boston, MA, United States of America
- Department of Biomedical Engineering, Boston University, Boston, MA, United States of America
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| | - Nina E Fultz
- Department of Biomedical Engineering, Boston University, Boston, MA, United States of America
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States of America
- Department of Radiology, Harvard Medical School, Boston, MA, United States of America
- Neurobiology Research Unit, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark
| | - Hongbae Jeong
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States of America
- Department of Radiology, Harvard Medical School, Boston, MA, United States of America
| | - Stephanie D Williams
- Department of Biomedical Engineering, Boston University, Boston, MA, United States of America
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| | - Daniel Gomez
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, United States of America
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States of America
- Department of Radiology, Harvard Medical School, Boston, MA, United States of America
| | - Beverly Setzer
- Graduate Program in Neuroscience, Boston University, Boston, MA, United States of America
- Department of Biomedical Engineering, Boston University, Boston, MA, United States of America
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| | | | | | - Ravij Gupta
- Department of Radiology, Harvard Medical School, Boston, MA, United States of America
| | - Michael Lev
- Department of Radiology, Harvard Medical School, Boston, MA, United States of America
| | - Giorgio Bonmassar
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States of America
- Department of Radiology, Harvard Medical School, Boston, MA, United States of America
| | - Laura D Lewis
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, United States of America
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, United States of America
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States of America
| |
Collapse
|
2
|
Winter L, Periquito J, Kolbitsch C, Pellicer-Guridi R, Nunes RG, Häuer M, Broche L, O'Reilly T. Open-source magnetic resonance imaging: Improving access, science, and education through global collaboration. NMR IN BIOMEDICINE 2024; 37:e5052. [PMID: 37986655 DOI: 10.1002/nbm.5052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2023] [Revised: 08/01/2023] [Accepted: 09/09/2023] [Indexed: 11/22/2023]
Abstract
Open-source practices and resources in magnetic resonance imaging (MRI) have increased substantially in recent years. This trend started with software and data being published open-source and, more recently, open-source hardware designs have become increasingly available. These developments towards a culture of sharing and establishing nonexclusive global collaborations have already improved the reproducibility and reusability of code and designs, while providing a more inclusive approach, especially for low-income settings. Community-driven standardization and documentation efforts are further strengthening and expanding these milestones. The future of open-source MRI is bright and we have just started to discover its full collaborative potential. In this review we will give an overview of open-source software and open-source hardware projects in human MRI research.
Collapse
Affiliation(s)
- Lukas Winter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - João Periquito
- Department of Infection, Immunity & Cardiovascular Disease, The University of Sheffield, Sheffield, UK
| | - Christoph Kolbitsch
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | | | - Rita G Nunes
- Institute for Systems and Robotics and Department of Bioengineering, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
| | - Martin Häuer
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
- Open Source Ecology Germany e.V. (nonprofit), Berlin, Germany
| | - Lionel Broche
- Biomedical Physics, University of Aberdeen, Aberdeen, UK
| | - Tom O'Reilly
- Leiden University Medical Center (LUMC), Leiden, The Netherlands
| |
Collapse
|
3
|
Lakshmanan K, Wang B, Walczyk J, Collins CM, Brown R. Three-row MRI receive array with remote circuitry to preserve radiation transparency. Phys Med Biol 2024; 69:10.1088/1361-6560/ad388c. [PMID: 38537307 PMCID: PMC11071057 DOI: 10.1088/1361-6560/ad388c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Accepted: 03/27/2024] [Indexed: 04/18/2024]
Abstract
Objective.Up to this point, 1.5 T linac-compatible coil array layouts have been restricted to one or two rows of coils because of the desire to place radiation-opaque circuitry adjacent to the coils and outside the window through which the linac beam travels. Such layouts can limit parallel imaging performance. The purpose of this work was to design and build a three-row array in which remotely located circuits permitted a central row of coils while preserving the radiolucent window.Approach.The remote circuits consisted of a phase shifter to cancel the phase introduced by the coaxial link between the circuit and coil, followed by standard components for tuning, matching, detuning, and preamplifier decoupling. Tests were performed to compare prototype single-channel coils with remote or local circuits, which were followed by tests comparing two and three-row arrays .Main results.The single-channel coil with the remote circuit maintained 85% SNR at depths of 30 mm or more as compared to a coil with local circuit. The three-row array provided similar SNR as the two-row array, along with geometry factor advantages for parallel imaging acceleration in the head-foot direction.Significance.The remote circuit strategy could potentially support future MR-linac arrays by allowing greater flexibility in array layout compared to those confined by local circuits, which can be leveraged for parallel imaging acceleration.
Collapse
Affiliation(s)
- Karthik Lakshmanan
- Center for Advanced Imaging Innovation and Research, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
- Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
| | - Bili Wang
- Center for Advanced Imaging Innovation and Research, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
- Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
| | - Jerzy Walczyk
- Center for Advanced Imaging Innovation and Research, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
- Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
| | - Christopher M. Collins
- Center for Advanced Imaging Innovation and Research, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
- Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
| | - Ryan Brown
- Center for Advanced Imaging Innovation and Research, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
- Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
| |
Collapse
|
4
|
Rios NL, Gilbert KM, Papp D, Cereza G, Foias A, Rangaprakash D, May MW, Guerin B, Wald LL, Keil B, Stockmann JP, Barry RL, Cohen-Adad J. An 8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla. NMR IN BIOMEDICINE 2023; 36:e5002. [PMID: 37439129 PMCID: PMC10733907 DOI: 10.1002/nbm.5002] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 05/10/2023] [Accepted: 06/15/2023] [Indexed: 07/14/2023]
Abstract
The quality of cervical spinal cord images can be improved by the use of tailored radiofrequency (RF) coil solutions for ultrahigh field imaging; however, very few commercial and research 7-T RF coils currently exist for the spinal cord, and in particular, those with parallel transmission (pTx) capabilities. This work presents the design, testing, and validation of a pTx/Rx coil for the human neck and cervical/upper thoracic spinal cord. The pTx portion is composed of eight dipoles to ensure high homogeneity over this large region of the spinal cord. The Rx portion is made up of twenty semiadaptable overlapping loops to produce high signal-to-noise ratio (SNR) across the patient population. The coil housing is designed to facilitate patient positioning and comfort, while also being tight fitting to ensure high sensitivity. We demonstrate RF shimming capabilities to optimize B1 + uniformity, power efficiency, and/or specific absorption rate efficiency. B1 + homogeneity, SNR, and g-factor were evaluated in adult volunteers and demonstrated excellent performance from the occipital lobe down to the T4-T5 level. We compared the proposed coil with two state-of-the-art head and head/neck coils, confirming its superiority in the cervical and upper thoracic regions of the spinal cord. This coil solution therefore provides a convincing platform for producing the high image quality necessary for clinical and research scanning of the upper spinal cord.
Collapse
Affiliation(s)
- Nibardo Lopez Rios
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montréal, QC, Canada
| | - Kyle M. Gilbert
- Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, ON, Canada
| | - Daniel Papp
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montréal, QC, Canada
| | - Gaspard Cereza
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montréal, QC, Canada
| | - Alexandru Foias
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montréal, QC, Canada
| | - D. Rangaprakash
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Markus W. May
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University of Duisburg-Essen, Essen, Germany
- High Field and Hybrid MR Imaging, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Bastien Guerin
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Lawrence L. Wald
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
- Harvard Medical School, Boston, MA, USA
- Harvard-Massachusetts Institute of Technology Health Sciences & Technology, Cambridge, MA, USA
| | - Boris Keil
- Institute of Medical Physics and Radiation Protection, University of Applied Sciences Mittelhessen, Giessen, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Marburg, Philipps University of Marburg, Marburg, Germany
| | - Jason P. Stockmann
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Robert L. Barry
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
- Harvard Medical School, Boston, MA, USA
- Harvard-Massachusetts Institute of Technology Health Sciences & Technology, Cambridge, MA, USA
| | - Julien Cohen-Adad
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montréal, QC, Canada
- Functional Neuroimaging Unit, CRIUGM, Université de Montréal, Montreal, QC, Canada
- Mila – Quebec AI Institute, Montreal, QC, Canada
- Centre de recherche du CHU Sainte-Justine, Université de Montréal, Montréal, QC, Canada
| |
Collapse
|
5
|
Kumar N, Alathur Ramakrishnan S, Lopez KG, Wang N, Vellayappan BA, Hallinan JTPD, Fuh JYH, Kumar AS. Novel 3D printable PEEK-HA-Mg 2SiO 4 composite material for spine implants: biocompatibility and imaging compatibility assessments. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2023; 32:2255-2265. [PMID: 37179256 DOI: 10.1007/s00586-023-07734-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 04/14/2023] [Accepted: 04/19/2023] [Indexed: 05/15/2023]
Abstract
PURPOSE To develop a novel 3D printable polyether ether ketone (PEEK)-hydroxyapatite (HA)-magnesium orthosilicate (Mg2SiO4) composite material with enhanced properties for potential use in tumour, osteoporosis and other spinal conditions. We aim to evaluate biocompatibility and imaging compatibility of the material. METHODS Materials were prepared in three different compositions, namely composite A: 75 weight % PEEK, 20 weight % HA, 5 weight % Mg2SiO4; composite B: 70 weight% PEEK, 25 weight % HA, 5 weight % Mg2SiO4; and composite C: 65 weight % PEEK, 30 weight % HA, 5 weight % Mg2SiO4. The materials were processed to obtain 3D printable filament. Biomechanical properties were analysed as per ASTM standards and biocompatibility of the novel material was evaluated using indirect and direct cell cytotoxicity tests. Cell viability of the novel material was compared to PEEK and PEEK-HA materials. The novel material was used to 3D print a standard spine cage. Furthermore, the CT and MR imaging compatibility of the novel material cage vs PEEK and PEEK-HA cages were evaluated using a phantom setup. RESULTS Composite A resulted in optimal material processing to obtain a 3D printable filament, while composite B and C resulted in non-optimal processing. Composite A enhanced cell viability up to ~ 20% compared to PEEK and PEEK-HA materials. Composite A cage generated minimal/no artefacts on CT and MR imaging and the images were comparable to that of PEEK and PEEK-HA cages. CONCLUSION Composite A demonstrated superior bioactivity vs PEEK and PEEK-HA materials and comparable imaging compatibility vs PEEK and PEEK-HA. Therefore, our material displays an excellent potential to manufacture spine implants with enhanced mechanical and bioactive property.
Collapse
Affiliation(s)
- Naresh Kumar
- Department of Orthopaedic Surgery, National University Health System, Level 11 Tower Block, 1E, Lower Kent Ridge Road, Singapore, 119228, Singapore.
| | - Sridharan Alathur Ramakrishnan
- Department of Orthopaedic Surgery, National University Health System, Level 11 Tower Block, 1E, Lower Kent Ridge Road, Singapore, 119228, Singapore
| | - Keith Gerard Lopez
- Department of Orthopaedic Surgery, National University Health System, Level 11 Tower Block, 1E, Lower Kent Ridge Road, Singapore, 119228, Singapore
| | - Niyou Wang
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117575, Singapore
| | - Balamurugan A Vellayappan
- Department of Radiation Oncology, National University Health System, Level 7, Tower Block, 1E, Lower Kent Ridge Road, Singapore, 119228, Singapore
| | - James Thomas Patrick Decourcy Hallinan
- Department of Diagnostic Imaging, National University Hospital, National University Hospital Main Building, Level 2, 5 Lower Kent Ridge Rd, Singapore, 119074, Singapore
| | - Jerry Ying Hsi Fuh
- Department of Mechanical Engineering, National University of Singapore, #04-18 Block EA, 9 Engineering Drive 1, Singapore, 117575, Singapore
| | - A Senthil Kumar
- Department of Mechanical Engineering, National University of Singapore, #05-26 Block EA, 9 Engineering Drive 1, Singapore, 117575, Singapore
| |
Collapse
|
6
|
Xu G, Zhang Q, Liu H, Qiu B, Yu X, Nan X, Han J. A Reliable Approach for Fabricating Tissue-Mimicking Phantoms with Designated Dielectric Properties from 16 MHz to 3 GHz. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38083475 DOI: 10.1109/embc40787.2023.10340202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Tissue-mimicking dielectric phantoms are widely used to mimic the relative permittivity and conductivity of human tissues in various medical applications. The artificial material combinations determine the characterization of dialectic phantoms. However, a method that reliably determined the composition of artificial materials with designed values of dielectric properties and frequency is still lacking. In this work, we propose a method that easily determine the compositions of phantom to mimic the human tissues from 16 MHz to 3 GHz.
Collapse
|
7
|
Kumar N, Alathur Ramakrishnan S, Lopez KG, Wang N, Madhu S, Vellayappan BA, Tpd Hallinan J, Fuh JYH, Kumar AS. Design and 3D printing of novel titanium spine rods with lower flexural modulus and stiffness profile with optimised imaging compatibility. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2023; 32:1953-1965. [PMID: 37052651 DOI: 10.1007/s00586-023-07674-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 03/07/2023] [Accepted: 03/18/2023] [Indexed: 04/14/2023]
Abstract
PURPOSE To manufacture and test 3D printed novel design titanium spine rods with lower flexural modulus and stiffness compared to standard solid titanium rods for use in metastatic spine tumour surgery (MSTS) and osteoporosis. METHODS Novel design titanium spine rods were designed and 3D printed. Three-point bending test was performed to assess mechanical performance of rods, while a French bender was used to assess intraoperative rod contourability. Furthermore, 3D printed spine rods were tested for CT & MR imaging compatibility using phantom setup. RESULTS Different spine rod designs generated includes shell, voronoi, gyroid, diamond, weaire-phelan, kelvin, and star. Tests showed 3D printed rods had lower flexural modulus with reduction ranging from 2 to 25% versus standard rod. Shell rods exhibited highest reduction in flexural modulus of 25% (~ 77.4 GPa) and star rod exhibited lowest reduction in flexural modulus of 2% (100.8GPa). 3D printed rod showed reduction in stiffness ranging from 40 to 59%. Shell rod displayed highest reduction in stiffness of 59% (179.9 N/mm) and gyroid had least reduction in stiffness of 40% (~ 259.2 N/mm). Rod bending test showed that except gyroid, other rod designs demonstrated lesser bending difficulty versus standard rod. All 3D printed rods demonstrated improved CT/MR imaging compatibility with reduced artefacts versus standard rod. CONCLUSION By utilising novel design approach, we successfully generated a spine rod design portfolio with lower flexural modulus/stiffness profile and better CT/MR imaging compatibility for potential use in MSTS/other conditions such as osteoporosis. Thus, exploration of new rod designs in surgical application could enhance treatment outcome and improve quality of life for patients.
Collapse
Affiliation(s)
- Naresh Kumar
- Department of Orthopaedic Surgery, National University Health System, Level 11 Tower Block, 1E, Lower Kent Ridge Road, Singapore, 119228, Singapore.
| | - Sridharan Alathur Ramakrishnan
- Department of Orthopaedic Surgery, National University Health System, Level 11 Tower Block, 1E, Lower Kent Ridge Road, Singapore, 119228, Singapore
| | - Keith Gerard Lopez
- Department of Orthopaedic Surgery, National University Health System, Level 11 Tower Block, 1E, Lower Kent Ridge Road, Singapore, 119228, Singapore
| | - Niyou Wang
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117575, Singapore
| | - Sirisha Madhu
- Department of Orthopaedic Surgery, National University Health System, Level 11 Tower Block, 1E, Lower Kent Ridge Road, Singapore, 119228, Singapore
| | - Balamurugan A Vellayappan
- Department of Radiation Oncology, National University Health System, Level 7 Tower Block, 1E, Lower Kent Ridge Road, Singapore, 119228, Singapore
| | - James Tpd Hallinan
- Department of Diagnostic Imaging, National University Hospital, Level 2 National University Hospital Main Building, 5 Lower Kent Ridge Rd, Singapore, 119074, Singapore
| | - Jerry Ying Hsi Fuh
- Department of Mechanical Engineering, National University of Singapore, #04-18 Block EA, 9 Engineering Drive 1, Singapore, 117575, Singapore
| | - A Senthil Kumar
- Department of Mechanical Engineering, National University of Singapore, #05-26 Block EA, 9 Engineering Drive 1, Singapore, 117575, Singapore
| |
Collapse
|
8
|
Androulakis I, Ferrero R, van Oossanen R, Manzin A, Denkova AG, Djanashvili K, Nadar R, van Rhoon GC. Design and Validation of Experimental Setup for Cell Spheroid Radiofrequency-Induced Heating. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094514. [PMID: 37177718 PMCID: PMC10181764 DOI: 10.3390/s23094514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 05/03/2023] [Accepted: 05/05/2023] [Indexed: 05/15/2023]
Abstract
While hyperthermia has been shown to induce a variety of cytotoxic and sensitizing effects on cancer tissues, the thermal dose-effect relationship is still not well quantified, and it is still unclear how it can be optimally combined with other treatment modalities. Additionally, it is speculated that different methods of applying hyperthermia, such as water bath heating or electromagnetic energy, may have an effect on the resulting biological mechanisms involved in cell death or in sensitizing tumor cells to other oncological treatments. In order to further quantify and characterize hyperthermia treatments on a cellular level, in vitro experiments shifted towards the use of 3D cell spheroids. These are in fact considered a more representative model of the cell environment when compared to 2D cell cultures. In order to perform radiofrequency (RF)-induced heating in vitro, we have recently developed a dedicated electromagnetic field applicator. In this study, using this applicator, we designed and validated an experimental setup which can heat 3D cell spheroids in a conical polypropylene vial, thus providing a reliable instrument for investigating hyperthermia effects at the cellular scale.
Collapse
Affiliation(s)
- Ioannis Androulakis
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, 3015 GD Rotterdam, The Netherlands
| | - Riccardo Ferrero
- Istituto Nazionale di Ricerca Metrologica (INRIM), 10135 Turin, Italy
| | - Rogier van Oossanen
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, 3015 GD Rotterdam, The Netherlands
- Department of Radiation Science and Technology, TU Delft, 2629 JB Delft, The Netherlands
| | - Alessandra Manzin
- Istituto Nazionale di Ricerca Metrologica (INRIM), 10135 Turin, Italy
| | - Antonia G Denkova
- Department of Radiation Science and Technology, TU Delft, 2629 JB Delft, The Netherlands
| | | | - Robin Nadar
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, 3015 GD Rotterdam, The Netherlands
- Department of Radiation Science and Technology, TU Delft, 2629 JB Delft, The Netherlands
| | - Gerard C van Rhoon
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, 3015 GD Rotterdam, The Netherlands
- Department of Radiation Science and Technology, TU Delft, 2629 JB Delft, The Netherlands
| |
Collapse
|
9
|
Jeong H, Ntolkeras G, Warbrick T, Jaschke M, Gupta R, Lev MH, Peters JM, Grant PE, Bonmassar G. Aluminum Thin Film Nanostructure Traces in Pediatric EEG Net for MRI and CT Artifact Reduction. SENSORS (BASEL, SWITZERLAND) 2023; 23:3633. [PMID: 37050693 PMCID: PMC10098641 DOI: 10.3390/s23073633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/24/2023] [Accepted: 03/28/2023] [Indexed: 06/19/2023]
Abstract
Magnetic resonance imaging (MRI) and continuous electroencephalogram (EEG) monitoring are essential in the clinical management of neonatal seizures. EEG electrodes, however, can significantly degrade the image quality of both MRI and CT due to substantial metallic artifacts and distortions. Thus, we developed a novel thin film trace EEG net ("NeoNet") for improved MRI and CT image quality without compromising the EEG signal quality. The aluminum thin film traces were fabricated with an ultra-high-aspect ratio (up to 17,000:1, with dimensions 30 nm × 50.8 cm × 100 µm), resulting in a low density for reducing CT artifacts and a low conductivity for reducing MRI artifacts. We also used numerical simulation to investigate the effects of EEG nets on the B1 transmit field distortion in 3 T MRI. Specifically, the simulations predicted a 65% and 138% B1 transmit field distortion higher for the commercially available copper-based EEG net ("CuNet", with and without current limiting resistors, respectively) than with NeoNet. Additionally, two board-certified neuroradiologists, blinded to the presence or absence of NeoNet, compared the image quality of MRI images obtained in an adult and two children with and without the NeoNet device and found no significant difference in the degree of artifact or image distortion. Additionally, the use of NeoNet did not cause either: (i) CT scan artifacts or (ii) impact the quality of EEG recording. Finally, MRI safety testing confirmed a maximum temperature rise associated with the NeoNet device in a child head-phantom to be 0.84 °C after 30 min of high-power scanning, which is within the acceptance criteria for the temperature for 1 h of normal operating mode scanning as per the FDA guidelines. Therefore, the proposed NeoNet device has the potential to allow for concurrent EEG acquisition and MRI or CT scanning without significant image artifacts, facilitating clinical care and EEG/fMRI pediatric research.
Collapse
Affiliation(s)
- Hongbae Jeong
- AA. Martinos Center, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA 02129, USA
| | - Georgios Ntolkeras
- Department of Newborn Medicine, Fetal-Neonatal Neuroimaging and Developmental Science Center, Boston Children’s Hospital, Boston, MA 02115, USA
- Department of Pediatrics, Baystate Medical Center, University of Massachusetts Medical School, Springfield, MA 01605, USA
| | | | | | - Rajiv Gupta
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Michael H. Lev
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Jurriaan M. Peters
- Department of Neurology, Boston Children’s Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Patricia Ellen Grant
- Department of Newborn Medicine, Fetal-Neonatal Neuroimaging and Developmental Science Center, Boston Children’s Hospital, Boston, MA 02115, USA
| | - Giorgio Bonmassar
- AA. Martinos Center, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA 02129, USA
- Department of Newborn Medicine, Fetal-Neonatal Neuroimaging and Developmental Science Center, Boston Children’s Hospital, Boston, MA 02115, USA
| |
Collapse
|
10
|
Levitt J, van der Kouwe A, Jeong H, Lewis LD, Bonmassar G. The MotoNet: A 3 Tesla MRI-Conditional EEG Net with Embedded Motion Sensors. SENSORS (BASEL, SWITZERLAND) 2023; 23:3539. [PMID: 37050598 PMCID: PMC10098760 DOI: 10.3390/s23073539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 03/20/2023] [Accepted: 03/23/2023] [Indexed: 06/19/2023]
Abstract
We introduce a new electroencephalogram (EEG) net, which will allow clinicians to monitor EEG while tracking head motion. Motion during MRI limits patient scans, especially of children with epilepsy. EEG is also severely affected by motion-induced noise, predominantly ballistocardiogram (BCG) noise due to the heartbeat. METHODS The MotoNet was built using polymer thick film (PTF) EEG leads and motion sensors on opposite sides in the same flex circuit. EEG/motion measurements were made with a standard commercial EEG acquisition system in a 3 Tesla (T) MRI. A Kalman filtering-based BCG correction tool was used to clean the EEG in healthy volunteers. RESULTS MRI safety studies in 3 T confirmed the maximum heating below 1 °C. Using an MRI sequence with spatial localization gradients only, the position of the head was linearly correlated with the average motion sensor output. Kalman filtering was shown to reduce the BCG noise and recover artifact-clean EEG. CONCLUSIONS The MotoNet is an innovative EEG net design that co-locates 32 EEG electrodes with 32 motion sensors to improve both EEG and MRI signal quality. In combination with custom gradients, the position of the net can, in principle, be determined. In addition, the motion sensors can help reduce BCG noise.
Collapse
Affiliation(s)
- Joshua Levitt
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - André van der Kouwe
- Athinoula A. Martinos Center for Biomedical Engineering, Massachusetts General Hospital, Charlestown, MA 02129, USA
| | - Hongbae Jeong
- Athinoula A. Martinos Center for Biomedical Engineering, Massachusetts General Hospital, Charlestown, MA 02129, USA
| | - Laura D. Lewis
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
- Athinoula A. Martinos Center for Biomedical Engineering, Massachusetts General Hospital, Charlestown, MA 02129, USA
| | - Giorgio Bonmassar
- Athinoula A. Martinos Center for Biomedical Engineering, Massachusetts General Hospital, Charlestown, MA 02129, USA
| |
Collapse
|
11
|
Berangi M, Kuehne A, Waiczies H, Niendorf T. MRI of Implantation Sites Using Parallel Transmission of an Optimized Radiofrequency Excitation Vector. Tomography 2023; 9:603-620. [PMID: 36961008 PMCID: PMC10037644 DOI: 10.3390/tomography9020049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 03/03/2023] [Accepted: 03/05/2023] [Indexed: 03/25/2023] Open
Abstract
Postoperative care of orthopedic implants is aided by imaging to assess the healing process and the implant status. MRI of implantation sites might be compromised by radiofrequency (RF) heating and RF transmission field (B1+) inhomogeneities induced by electrically conducting implants. This study examines the applicability of safe and B1+-distortion-free MRI of implantation sites using optimized parallel RF field transmission (pTx) based on a multi-objective genetic algorithm (GA). Electromagnetic field simulations were performed for eight eight-channel RF array configurations (f = 297.2 MHz), and the most efficient array was manufactured for phantom experiments at 7.0 T. Circular polarization (CP) and orthogonal projection (OP) algorithms were applied for benchmarking the GA-based shimming. B1+ mapping and MR thermometry and imaging were performed using phantoms mimicking muscle containing conductive implants. The local SAR10g of the entire phantom in GA was 12% and 43.8% less than the CP and OP, respectively. Experimental temperature mapping using the CP yielded ΔT = 2.5-3.0 K, whereas the GA induced no extra heating. GA-based shimming eliminated B1+ artefacts at implantation sites and enabled uniform gradient-echo MRI. To conclude, parallel RF transmission with GA-based excitation vectors provides a technical foundation en route to safe and B1+-distortion-free MRI of implantation sites.
Collapse
Affiliation(s)
- Mostafa Berangi
- Berlin Ultrahigh Field Facility, Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association, 13125 Berlin, Germany
- Charité-Universitätsmedizin Berlin, 10117 Berlin, Germany
- MRI.TOOLS GmbH, 13125 Berlin, Germany
| | | | | | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility, Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association, 13125 Berlin, Germany
- Charité-Universitätsmedizin Berlin, 10117 Berlin, Germany
- MRI.TOOLS GmbH, 13125 Berlin, Germany
| |
Collapse
|
12
|
Rios NL, Gilbert KM, Papp D, Cereza G, Foias A, Rangaprakash D, May MW, Guerin B, Wald LL, Keil B, Stockmann JP, Barry RL, Cohen-Adad J. 8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.02.08.527664. [PMID: 36798276 PMCID: PMC9934596 DOI: 10.1101/2023.02.08.527664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The quality of cervical spinal cord images can be improved by the use of tailored radiofrequency coil solutions for ultra-high field imaging; however, very few commercial and research 7 Tesla radiofrequency coils currently exist for the spinal cord, and in particular those with parallel transmit capabilities. This work presents the design, testing and validation of a pTx/Rx coil for the human neck and cervical/upper-thoracic spinal cord. The pTx portion is composed of 8 dipoles to ensure high homogeneity over this large region of the spinal cord. The Rx portion is made of 20 semi-adaptable overlapping loops to produce high Signal-to-noise ratio (SNR) across the patient population. The coil housing is designed to facilitate patient positioning and comfort, while being tight fitting to ensure high sensitivity. We demonstrate RF shimming capabilities to optimize B 1 + uniformity, power efficiency and/or specific absorption rate (SAR) efficiency. B 1 + homogeneity, SNR and g-factor was evaluated in adult volunteers and demonstrated excellent performance from the occipital lobe down to the T4-T5 level. We compared the proposed coil with two state-of-the-art head and head/neck coils, confirming its superiority in the cervical and upper-thoracic regions of the spinal cord. This coil solution therefore provides a convincing platform for producing the high image quality necessary for clinical and research scanning of the upper spinal cord.
Collapse
Affiliation(s)
- Nibardo Lopez Rios
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montreal, QC, Canada
| | - Kyle M. Gilbert
- Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, ON, Canada
| | - Daniel Papp
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montreal, QC, Canada
| | - Gaspard Cereza
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montreal, QC, Canada
| | - Alexandru Foias
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montreal, QC, Canada
| | - D. Rangaprakash
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Markus W. May
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University of Duisburg-Essen, Essen, Germany
- High Field and Hybrid MR Imaging, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Bastien Guerin
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Lawrence L. Wald
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
- Harvard Medical School, Boston, MA, USA
- Harvard-Massachusetts Institute of Technology Health Sciences & Technology, Cambridge, MA, USA
| | - Boris Keil
- Institute of Medical Physics and Radiation Protection, University of Applied Sciences Mittelhessen, Giessen, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Marburg, Philipps University of Marburg, Marburg, Germany
| | - Jason P. Stockmann
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Robert L. Barry
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
- Harvard Medical School, Boston, MA, USA
- Harvard-Massachusetts Institute of Technology Health Sciences & Technology, Cambridge, MA, USA
| | - Julien Cohen-Adad
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montreal, QC, Canada
- Functional Neuroimaging Unit, CRIUGM, Université de Montréal, Montreal, QC, Canada
- Mila – Quebec AI Institute, Montreal, QC, Canada
- Centre de recherche du CHU Sainte-Justine, Université de Montréal, Montréal, QC, Canada
| |
Collapse
|
13
|
De Lazzari M, Ström A, Farina L, Silva NP, Curto S, Trefná HD. Ethylcellulose-stabilized fat-tissue phantom for quality assurance in clinical hyperthermia. Int J Hyperthermia 2023; 40:2207797. [PMID: 37196995 DOI: 10.1080/02656736.2023.2207797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 04/10/2023] [Accepted: 04/21/2023] [Indexed: 05/19/2023] Open
Abstract
BACKGROUND Phantoms accurately mimicking the electromagnetic and thermal properties of human tissues are essential for the development, characterization, and quality assurance (QA) of clinically used equipment for Hyperthermia Treatment (HT). Currently, a viable recipe for a fat equivalent phantom is not available, mainly due to challenges in the fabrication process and fast deterioration. MATERIALS AND METHODS We propose to employ a glycerol-in-oil emulsion stabilized with ethylcellulose to develop a fat-mimicking material. The dielectric, rheological, and thermal properties of the phantom have been assessed by state-of-the-art measurement techniques. The full-size phantom was then verified in compliance with QA guidelines for superficial HT, both numerically and experimentally, considering the properties variability. RESULTS Dielectric and thermal properties were proven equivalent to fat tissue, with an acceptable variability, in the 8 MHz to 1 GHz range. The rheology measurements highlighted enhanced mechanical stability over a large temperature range. Both numerical and experimental evaluations proved the suitability of the phantom for QA procedures. The impact of the dielectric property variations on the temperature distribution has been numerically proven to be limited (around 5%), even if higher for capacitive devices (up to 20%). CONCLUSIONS The proposed fat-mimicking phantom is a good candidate for hyperthermia technology assessment processes, adequately representing both dielectric and thermal properties of the human fat tissue while maintaining structural stability even at elevated temperatures. However, further experimental investigations on capacitive heating devices are necessary to better assess the impact of the low electrical conductivity values on the thermal distribution.
Collapse
Affiliation(s)
- Mattia De Lazzari
- Biomedical Electromagnetics, Electrical Engineering, Chalmers University of Technology, Göteborg, Sweden
| | - Anna Ström
- Applied Chemistry, Chemistry and Chemical Engineering, Chalmers University of Technology, Göteborg, Sweden
| | - Laura Farina
- Translational Medical Device Lab, University of Galway, Galway, Ireland
| | - Nuno P Silva
- Translational Medical Device Lab, University of Galway, Galway, Ireland
| | - Sergio Curto
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
| | - Hana Dobšíček Trefná
- Biomedical Electromagnetics, Electrical Engineering, Chalmers University of Technology, Göteborg, Sweden
| |
Collapse
|
14
|
Saleh G, Abuelhaija A, Alfaris B, Aljabr A, Zainalabedin M, Mhareb MHA, Alhashim M, Alenezi S. Heterogeneous breast phantom for computed tomography and magnetic resonance imaging. PLoS One 2023; 18:e0284531. [PMID: 37053345 PMCID: PMC10101397 DOI: 10.1371/journal.pone.0284531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Accepted: 04/02/2023] [Indexed: 04/15/2023] Open
Abstract
In this article, a heterogeneous multimodal anthropomorphic breast phantom with carcinoma is introduced to meet the response of the natural breast tissue when imaged using ionizing and non-ionizing machines. The skin, adipose, fibroglandular, pectoral muscle, and carcinoma tissue were mimicked. A T1-weighted breast magnetic resonance image with BI-RADS I tissue segmentation was used for molds creation. The tissue-mimicking materials (TMMs) were tailored in terms of their elemental composition weight fractions and their response to ionization radiation parameters. These are the mass attenuation coefficient (MAC), electron density (ne) and effective atomic number (Zeff). The behaviour of the TMMs, when exposed to a wide range of ionization radiation energy, was investigated analytically and numerically using X-COM. The achieved results showed an excellent agreement with the corresponding properties of the natural breast elemental compositions as reported by the International Commission on Radiation Units and Measurements (ICRU). The MAC of the TMMs and the ICRU-based breast tissue were found to be consistent. The maximum percentage of error in ne and Zeff amounts to only 2.93% and 5.76%, respectively. For non-ionizing imaging, the TMMs were characterized in term of T1 and T2 relaxation times. Using our preclinical MRI unit, the TMMs relaxation times were measured and compared to the natural tissue. The fabricated phantom was validated experimentally using CT, MRI, and Mammographic machines. The achieved images of the TMMs were in alignment with the real tissue in terms of CT HU values and grayscale colors. T1W and T2W images on MRI revealed the expected contrast between TMMs as in natural tissue.
Collapse
Affiliation(s)
- Gameel Saleh
- Department of Biomedical Engineering, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ashraf Abuelhaija
- Department of Electrical Engineering, Faculty of Engineering and Technology, Applied Science Private University, Amman, Jordan
| | - Budour Alfaris
- Department of Biomedical Engineering, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Aljohara Aljabr
- Department of Biomedical Engineering, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Maryam Zainalabedin
- Department of Biomedical Engineering, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - M H A Mhareb
- Department of Physics, College of Science, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | | | - Salma Alenezi
- King Fahad Specialist Hospital (KFSH), Dammam, Saudi Arabia
| |
Collapse
|
15
|
Roig ES, De Feyter HM, Nixon TW, Ruhm L, Nikulin AV, Scheffler K, Avdievich NI, Henning A, de Graaf RA. Deuterium metabolic imaging of the human brain in vivo at 7 T. Magn Reson Med 2023; 89:29-39. [PMID: 36063499 PMCID: PMC9756916 DOI: 10.1002/mrm.29439] [Citation(s) in RCA: 17] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 07/25/2022] [Accepted: 08/11/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE To explore the potential of deuterium metabolic imaging (DMI) in the human brain in vivo at 7 T, using a multi-element deuterium (2 H) RF coil for 3D volume coverage. METHODS 1 H-MR images and localized 2 H MR spectra were acquired in vivo in the human brain of 3 healthy subjects to generate DMI maps of 2 H-labeled water, glucose, and glutamate/glutamine (Glx). In addition, non-localized 2 H-MR spectra were acquired both in vivo and in vitro to determine T1 and T2 relaxation times of deuterated metabolites at 7 T. The performance of the 2 H coil was assessed through numeric simulations and experimentally acquired B1 + maps. RESULTS 3D DMI maps covering the entire human brain in vivo were obtained from well-resolved deuterated (2 H) metabolite resonances of water, glucose, and Glx. The T1 and T2 relaxation times were consistent with those reported at adjacent field strengths. Experimental B1 + maps were in good agreement with simulations, indicating efficient and homogeneous B1 + transmission and low RF power deposition for 2 H, consistent with a similar array coil design reported at 9.4 T. CONCLUSION Here, we have demonstrated the successful implementation of 3D DMI in the human brain in vivo at 7 T. The spatial and temporal nominal resolutions achieved at 7 T (i.e., 2.7 mL in 28 min, respectively) were close to those achieved at 9.4 T and greatly outperformed DMI at lower magnetic fields. DMI at 7 T and beyond has clear potential in applications dealing with small brain lesions.
Collapse
Affiliation(s)
- Eulalia Serés Roig
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA
| | - Henk M. De Feyter
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA
| | - Terence W. Nixon
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA
| | - Loreen Ruhm
- High-Field MR Centre, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- IMPRS for Cognitive and Systems Neuroscience, Eberhard-Karls University of Tübingen, Tübingen, Germany
- Advanced Imaging Research Centre, University of Texas Southwestern Medical Centre, Dallas, Texas, USA
| | - Anton V. Nikulin
- High-Field MR Centre, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department of Biomedical Magnetic Resonance, Eberhard-Karls University of Tübingen, Tübingen, Germany
| | - Klaus Scheffler
- High-Field MR Centre, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department of Biomedical Magnetic Resonance, Eberhard-Karls University of Tübingen, Tübingen, Germany
| | - Nikolai I. Avdievich
- High-Field MR Centre, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Anke Henning
- High-Field MR Centre, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Advanced Imaging Research Centre, University of Texas Southwestern Medical Centre, Dallas, Texas, USA
| | - Robin A. de Graaf
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA
| |
Collapse
|
16
|
Starke L, Millward JM, Prinz C, Sherazi F, Waiczies H, Lippert C, Nazaré M, Paul F, Niendorf T, Waiczies S. First in vivo fluorine-19 magnetic resonance imaging of the multiple sclerosis drug siponimod. Theranostics 2023; 13:1217-1234. [PMID: 36923535 PMCID: PMC10008739 DOI: 10.7150/thno.77041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 01/10/2023] [Indexed: 02/17/2023] Open
Abstract
Theranostic imaging methods could greatly enhance our understanding of the distribution of CNS-acting drugs in individual patients. Fluorine-19 magnetic resonance imaging (19F MRI) offers the opportunity to localize and quantify fluorinated drugs non-invasively, without modifications and without the application of ionizing or other harmful radiation. Here we investigated siponimod, a sphingosine 1-phosphate (S1P) receptor antagonist indicated for secondary progressive multiple sclerosis (SPMS), to determine the feasibility of in vivo 19F MR imaging of a disease modifying drug. Methods: The 19F MR properties of siponimod were characterized using spectroscopic techniques. Four MRI methods were investigated to determine which was the most sensitive for 19F MR imaging of siponimod under biological conditions. We subsequently administered siponimod orally to 6 mice and acquired 19F MR spectra and images in vivo directly after administration, and in ex vivo tissues. Results: The 19F transverse relaxation time of siponimod was 381 ms when dissolved in dimethyl sulfoxide, and substantially reduced to 5 ms when combined with serum, and to 20 ms in ex vivo liver tissue. Ultrashort echo time (UTE) imaging was determined to be the most sensitive MRI technique for imaging siponimod in a biological context and was used to map the drug in vivo in the stomach and liver. Ex vivo images in the liver and brain showed an inhomogeneous distribution of siponimod in both organs. In the brain, siponimod accumulated predominantly in the cerebrum but not the cerebellum. No secondary 19F signals were detected from metabolites. From a translational perspective, we found that acquisitions done on a 3.0 T clinical MR scanner were 2.75 times more sensitive than acquisitions performed on a preclinical 9.4 T MR setup when taking changes in brain size across species into consideration and using equivalent relative spatial resolution. Conclusion: Siponimod can be imaged non-invasively using 19F UTE MRI in the form administered to MS patients, without modification. This study lays the groundwork for more extensive preclinical and clinical investigations. With the necessary technical development, 19F MRI has the potential to become a powerful theranostic tool for studying the time-course and distribution of CNS-acting drugs within the brain, especially during pathology.
Collapse
Affiliation(s)
- Ludger Starke
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility, Berlin, Germany.,Hasso Plattner Institute for Digital Engineering, University of Potsdam, Germany
| | - Jason M Millward
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility, Berlin, Germany.,Experimental and Clinical Research Center, a joint cooperation between the Charité Universitätsmedizin Berlin and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Christian Prinz
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility, Berlin, Germany.,SRH Fernhochschule - The Mobile University, Riedlingen, Germany
| | - Fatima Sherazi
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility, Berlin, Germany
| | | | - Christoph Lippert
- Hasso Plattner Institute for Digital Engineering, University of Potsdam, Germany
| | - Marc Nazaré
- Medicinal Chemistry, Leibniz-Institut fϋr Molekulare Pharmakologie (FMP), Berlin, Germany
| | - Friedemann Paul
- Experimental and Clinical Research Center, a joint cooperation between the Charité Universitätsmedizin Berlin and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health (BIH), Berlin, Germany
| | - Thoralf Niendorf
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility, Berlin, Germany.,Experimental and Clinical Research Center, a joint cooperation between the Charité Universitätsmedizin Berlin and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Sonia Waiczies
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility, Berlin, Germany.,Experimental and Clinical Research Center, a joint cooperation between the Charité Universitätsmedizin Berlin and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| |
Collapse
|
17
|
Hernandez D, Nam T, Jeong Y, Kim D, Kim KN. Study on the Effect of Non-Symmetrical Current Distribution Controlled by Capacitor Placement in Radio-Frequency Coils for 7T MRI. BIOSENSORS 2022; 12:867. [PMID: 36291004 PMCID: PMC9599509 DOI: 10.3390/bios12100867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 10/06/2022] [Accepted: 10/09/2022] [Indexed: 06/16/2023]
Abstract
In this paper, we present a study on the effects of varying the position of a single tuning capacitor in a circular loop coil as a mechanism to control and produce non-symmetric current distribution, such that could be used for magnetic resonance imaging (MRI) operating at ultra-high frequency (UHF). This study aims to demonstrate that the position of the tuning capacitor of a circular loop could improve the coupling between adjacent coils, used to optimize transmission field uniformity or intensity, improve signal-to-noise ratio (SNR) or specific absorption rate (SAR). A typical loop coil used in MRI consists of symmetrically distributed capacitors along the coil; this design is able to produce uniform current distributions inside the coil. However, in UHF conditions, the magnetic flux density (|B1+|) field produced by this setup may exhibit field distortion, requiring a method of controlling the field distribution and improving the field intensity of the circular loop coil. The control mechanism investigated in this study is based on the position of the tuning capacitor in the circular coil, the capacitor position was varied from 15° to 345°, in steps of 15°. We performed electromagnetic (EM) simulations, fabricated the coils, and performed MRI experiments at 7T, with each of the coils with capacitor position from 15° to 345° to determine the effects on field intensity, coupling between adjacent coils, SAR, and applications for field uniformity optimization. For the case of free space, a coil with capacitor position at 15° showed higher field intensity compared to the reference coil; while an improved decoupling was achieved when a coil had the capacitor placed at 180° and the other coil at 90°; in a similar matter, we discuss the results for SAR, field uniformity and an application with an array coil for the spinal cord.
Collapse
Affiliation(s)
- Daniel Hernandez
- Neuroscience Research Institute, Gachon University, Incheon 21988, Korea
| | - Taewoo Nam
- Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon 21999, Korea
| | - Yonghwa Jeong
- Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon 21999, Korea
| | - Donghyuk Kim
- Neuroscience Research Institute, Gachon University, Incheon 21988, Korea
| | - Kyoung-Nam Kim
- Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon 21999, Korea
- Department of Biomedical Engineering, Gachon University, Seongnam 13120, Korea
| |
Collapse
|
18
|
Correlation analysis between the complex electrical permittivity and relaxation time of tissue mimicking phantoms in 7 T MRI. Sci Rep 2022; 12:15444. [PMID: 36104392 PMCID: PMC9474530 DOI: 10.1038/s41598-022-19832-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Accepted: 09/05/2022] [Indexed: 12/04/2022] Open
Abstract
Dielectric relaxation theory describes the complex permittivity of a material in an alternating field; in particular, Debye theory relates the time it takes for an applied field to achieve the maximum polarization and the electrical properties of the material. Although, Debye’s equations were proposed for electrical polarization, in this study, we investigate the correlation between the magnetic longitudinal relaxation time T1 and the complex electrical permittivity of tissue-mimicking phantoms using a 7 T magnetic resonance scanner. We created phantoms that mimicked several human tissues with specific electrical properties. The electrical properties of the phantoms were measured using bench-test equipment. T1 values were acquired from phantoms using MRI. The measured values were fitted with functions based on dielectric estimations, using relaxation times of electrical polarization, and the mixture theory for dielectrics. The results show that, T1 and the real permittivity are correlated; therefore, the correlation can be approximated with a rational function in the case of water-based phantoms. The correlation between index loss and T1 was determined using a fitting function based on the Debye equation and mixture theory equation, in which the fraction of the materials was taken into account. This phantom study and analysis provide an insight into the application relaxation times used for estimating dielectric properties. Currently, the measurement of electrical properties based on dielectric relaxation theory is based on an antenna, sometimes invasive, that irradiates an electric field into a small sample; thus, it is not possible to create a map of electrical properties for a complex structure such as the human body. This study could be further used to compute the electrical properties maps of tissues by scanning images and measuring T1 maps.
Collapse
|
19
|
May MW, Hansen SLJD, Mahmutovic M, Scholz A, Kutscha N, Guerin B, Stockmann JP, Barry RL, Kazemivalipour E, Gumbrecht R, Kimmlingen R, Adriany M, Chang Y, Triantafyllou C, Knake S, Wald LL, Keil B. A patient-friendly 16-channel transmit/64-channel receive coil array for combined head-neck MRI at 7 Tesla. Magn Reson Med 2022; 88:1419-1433. [PMID: 35605167 PMCID: PMC9675905 DOI: 10.1002/mrm.29288] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 04/12/2022] [Accepted: 04/13/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE To extend the coverage of brain coil arrays to the neck and cervical-spine region to enable combined head and neck imaging at 7 Tesla (T) ultra-high field MRI. METHODS The coil array structures of a 64-channel receive coil and a 16-channel transmit coil were merged into one anatomically shaped close-fitting housing. Transmit characteristics were evaluated in a B1+ -field mapping study and an electromagnetic model. Receive SNR and the encoding capability for accelerated imaging were evaluated and compared with a commercially available 7 T brain array coil. The performance of the head-neck array coil was demonstrated in human volunteers using high-resolution accelerated imaging. RESULTS In the brain, the SNR matches the commercially available 32-channel brain array and showed improvements in accelerated imaging capabilities. More importantly, the constructed coil array improved the SNR in the face area, neck area, and cervical spine by a factor of 1.5, 3.4, and 5.2, respectively, in regions not covered by 32-channel brain arrays at 7 T. The interelement coupling of the 16-channel transmit coil ranged from -14 to -44 dB (mean = -19 dB, adjacent elements <-18 dB). The parallel 16-channel transmit coil greatly facilitates B1+ field shaping required for large FOV neuroimaging at 7 T. CONCLUSION This new head-neck array coil is the first demonstration of a device of this nature used for combined full-brain, head-neck, and cervical-spine imaging at 7 T. The array coil is well suited to provide large FOV images, which potentially improves ultrahigh field neuroimaging applications for clinical settings.
Collapse
Affiliation(s)
- Markus W May
- Institute of Medical Physics and Radiation Protection, Department of Life Science Engineering, Mittelhessen University of Applied Sciences, Giessen, Germany
| | - Sam-Luca J D Hansen
- Institute of Medical Physics and Radiation Protection, Department of Life Science Engineering, Mittelhessen University of Applied Sciences, Giessen, Germany
| | - Mirsad Mahmutovic
- Institute of Medical Physics and Radiation Protection, Department of Life Science Engineering, Mittelhessen University of Applied Sciences, Giessen, Germany
| | - Alina Scholz
- Institute of Medical Physics and Radiation Protection, Department of Life Science Engineering, Mittelhessen University of Applied Sciences, Giessen, Germany
| | - Nicolas Kutscha
- Institute of Medical Physics and Radiation Protection, Department of Life Science Engineering, Mittelhessen University of Applied Sciences, Giessen, Germany
| | - Bastien Guerin
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Jason P Stockmann
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Robert L Barry
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Ehsan Kazemivalipour
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | | | | | | | - Yulin Chang
- Siemens Medical Solutions USA, Inc., Malvern, Pennsylvania, USA
| | | | - Susanne Knake
- Department of Neurology, Philipps-Universität Marburg, Marburg, Germany
- Center for Mind, Brain and Behavior (CMBB), Philipps-University Marburg, Marburg, Germany
| | - Lawrence L Wald
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
- Division of Health Sciences and Technology, Harvard - Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Boris Keil
- Institute of Medical Physics and Radiation Protection, Department of Life Science Engineering, Mittelhessen University of Applied Sciences, Giessen, Germany
- Center for Mind, Brain and Behavior (CMBB), Philipps-University Marburg, Marburg, Germany
| |
Collapse
|
20
|
Kumaragamage C, Coppoli A, Brown PB, McIntyre S, Nixon TW, De Feyter HM, Mason GF, de Graaf RA. Short symmetric and highly selective asymmetric first and second order gradient modulated offset independent adiabaticity (GOIA) pulses for applications in clinical MRS and MRSI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2022; 341:107247. [PMID: 35691241 PMCID: PMC9933141 DOI: 10.1016/j.jmr.2022.107247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Revised: 05/04/2022] [Accepted: 05/31/2022] [Indexed: 06/15/2023]
Abstract
Gradient modulated RF pulses, especially gradient offset independent adiabaticity (GOIA) pulses, are increasingly gaining attention for high field clinical magnetic resonance spectroscopy and spectroscopic imaging (MRS/MRSI) due to the lower peak B1 amplitude and associated power demands achievable relative to its non-modulated adiabatic full passage counterparts. In this work we describe the development of two GOIA RF pulses: 1) A power efficient, 3.0 ms wideband uniform rate with smooth truncation (WURST) modulated RF pulse with 15 kHz bandwidth compatible with a clinically feasible peak B1 amplitude of 0.87 kHz (or 20 µT), and 2) A highly selective asymmetric 6.66 ms RF pulse with 20 kHz bandwidth designed to achieve a single-sided, fractional transition width of only 1.7%. Effects of potential asynchrony between RF and gradient-modulated (GM) waveforms for 3 ms GOIA-WURST RF pulses was evaluated by simulation and experimentally. Results demonstrate that a 20+ µs asynchrony between RF and GM functions substantially degrades inversion performance when using large RF offsets to achieve translation. A projection-based method is presented that allows a quick calibration of RF and GM asynchrony on pre-clinical/clinical MR systems. The asymmetric GOIA pulse was implemented within a multi-pulse OVS sequence to achieve power efficient, highly-selective, and B1 and T1-independent signal suppression for extracranial lipid suppression. The developed GOIA pulses were utilized with linear gradient modulation (X, Y, Z gradient fields), and with second-order-field modulations (Z2, X2Y2 gradient fields) to provide elliptically-shaped regions-of-interest for MRS and MRSI acquisitions. Both described GOIA-RF pulses have substantial clinical value; specifically, the 3.0 ms GOIA-WURST pulse is beneficial to realize short TE sLASER localized proton MRS/MRSI sequences, and the asymmetric GOIA RF pulse has applications in highly selective outer volume signal suppression to allow interrogation of tissue proximal to extracranial lipids with full-intensity.
Collapse
Affiliation(s)
- Chathura Kumaragamage
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA.
| | - Anastasia Coppoli
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA
| | - Peter B Brown
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA
| | - Scott McIntyre
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA
| | - Terence W Nixon
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA
| | - Henk M De Feyter
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA
| | - Graeme F Mason
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA; Department of Psychiatry, Yale University School of Medicine, New Haven, CT, USA; Department of Biomedical Engineering, Yale University School of Medicine, New Haven, CT, USA
| | - Robin A de Graaf
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA; Department of Biomedical Engineering, Yale University School of Medicine, New Haven, CT, USA
| |
Collapse
|
21
|
Herz S, Stefanescu MR, Lohr D, Vogel P, Kosmala A, Terekhov M, Weng AM, Grunz JP, Bley TA, Schreiber LM. Effects of image homogeneity on stenosis visualization at 7 T in a coronary artery phantom study: With and without B1-shimming and parallel transmission. PLoS One 2022; 17:e0270689. [PMID: 35767553 PMCID: PMC9242506 DOI: 10.1371/journal.pone.0270689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Accepted: 06/15/2022] [Indexed: 11/18/2022] Open
Abstract
Background To investigate the effects of B1-shimming and radiofrequency (RF) parallel transmission (pTX) on the visualization and quantification of the degree of stenosis in a coronary artery phantom using 7 Tesla (7 T) magnetic resonance imaging (MRI). Methods Stenosis phantoms with different grades of stenosis (0%, 20%, 40%, 60%, 80%, and 100%; 5 mm inner vessel diameter) were produced using 3D printing (clear resin). Phantoms were imaged with four different concentrations of diluted Gd-DOTA representing established arterial concentrations after intravenous injection in humans. Samples were centrally positioned in a thorax phantom of 30 cm diameter filled with a custom-made liquid featuring dielectric properties of muscle tissue. MRI was performed on a 7 T whole-body system. 2D-gradient-echo sequences were acquired with an 8-channel transmit 16-channel receive (8 Tx / 16 Rx) cardiac array prototype coil with and without pTX mode. Measurements were compared to those obtained with identical scan parameters using a commercially available 1 Tx / 16 Rx single transmit coil (sTX). To assess reproducibility, measurements (n = 15) were repeated at different horizontal angles with respect to the B0-field. Results B1-shimming and pTX markedly improved flip angle homogeneity across the thorax phantom yielding a distinctly increased signal-to-noise ratio (SNR) averaged over a whole slice relative to non-manipulated RF fields. Images without B1-shimming showed shading artifacts due to local B1+-field inhomogeneities, which hampered stenosis quantification in severe cases. In contrast, B1-shimming and pTX provided superior image homogeneity. Compared with a conventional sTX coil higher grade stenoses (60% and 80%) were graded significantly (p<0.01) more precise. Mild to moderate grade stenoses did not show significant differences. Overall, SNR was distinctly higher with B1-shimming and pTX than with the conventional sTX coil (inside the stenosis phantoms 14%, outside the phantoms 32%). Both full and half concentration (10.2 mM and 5.1 mM) of a conventional Gd-DOTA dose for humans were equally suitable for stenosis evaluation in this phantom study. Conclusions B1-shimming and pTX at 7 T can distinctly improve image homogeneity and therefore provide considerably more accurate MR image analysis, which is beneficial for imaging of small vessel structures.
Collapse
Affiliation(s)
- Stefan Herz
- Comprehensive Heart Failure Center (CHFC), Chair of Molecular and Cellular Imaging, University Hospital Würzburg, Würzburg, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
- * E-mail:
| | - Maria R. Stefanescu
- Comprehensive Heart Failure Center (CHFC), Chair of Molecular and Cellular Imaging, University Hospital Würzburg, Würzburg, Germany
| | - David Lohr
- Comprehensive Heart Failure Center (CHFC), Chair of Molecular and Cellular Imaging, University Hospital Würzburg, Würzburg, Germany
| | - Patrick Vogel
- Department of Experimental Physics V, University of Würzburg, Würzburg, Germany
| | - Aleksander Kosmala
- Comprehensive Heart Failure Center (CHFC), Chair of Molecular and Cellular Imaging, University Hospital Würzburg, Würzburg, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
| | - Maxim Terekhov
- Comprehensive Heart Failure Center (CHFC), Chair of Molecular and Cellular Imaging, University Hospital Würzburg, Würzburg, Germany
| | - Andreas M. Weng
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
| | - Jan-Peter Grunz
- Comprehensive Heart Failure Center (CHFC), Chair of Molecular and Cellular Imaging, University Hospital Würzburg, Würzburg, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
| | - Thorsten A. Bley
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
| | - Laura M. Schreiber
- Comprehensive Heart Failure Center (CHFC), Chair of Molecular and Cellular Imaging, University Hospital Würzburg, Würzburg, Germany
| |
Collapse
|
22
|
Puchnin V, Ivanov V, Gulyaev M, Pirogov Y, Zubkov M. Imaging Capabilities of the ¹H-X-Nucleus Metamaterial-Inspired Multinuclear RF-Coil. IEEE TRANSACTIONS ON MEDICAL IMAGING 2022; 41:1587-1595. [PMID: 35030077 DOI: 10.1109/tmi.2022.3143693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
In this paper, we present the initial experimental investigation of a two-coil receive/transmit design for small animals imaging at 7T MRI. The system uses a butterfly-type coil tuned to 300 MHz for scanning the 1H nuclei and a non-resonant loop antenna with a metamaterial-inspired resonator with the ability to tune over a wide frequency range for X-nuclei. 1H, 31P, 23Na and 13C, which are of particular interest in biomedical MRI, were selected as test nuclei in this work. Coil simulations show the two parts of the radiofrequency (RF) assembly to be decoupled and operating independently due to the orthogonality of the excited RF transverse magnetic fields. Simulations and phantom experimental imaging show sufficiently homogeneous transverse transmit RF fields and tuning capabilities for the pilot multiheteronuclear experiments.
Collapse
|
23
|
Guerrero Orozco L, Peterson L, Fhager A. Microwave Antenna System for Muscle Rupture Imaging with a Lossy Gel to Reduce Multipath Interference. SENSORS 2022; 22:s22114121. [PMID: 35684742 PMCID: PMC9185596 DOI: 10.3390/s22114121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 05/13/2022] [Accepted: 05/26/2022] [Indexed: 12/03/2022]
Abstract
Injuries to the hamstring muscles are an increasing problem in sports. Imaging plays a key role in diagnosing and managing athletes with muscle injuries, but there are several problems with conventional imaging modalities with respect to cost and availability. We hypothesized that microwave imaging could provide improved availability and lower costs and lead to improved and more accurate diagnostics. In this paper, a semicircular microwave imaging array with eight antennae was investigated. A key component in this system is the novel antenna design, which is based on a monopole antenna and a lossy gel. The purpose of the gel is to reduce the effects of multipath signals and improve the imaging quality. Several different gels have been manufactured and evaluated in imaging experiments. For comparison, corresponding simulations were performed. The results showed that the gels can effectively reduce the multipath signals and the imaging experiments resulted in significantly more stable and repeatable reconstructions when a lossy gel was used compared to when an almost non-lossy gel was used.
Collapse
Affiliation(s)
- Laura Guerrero Orozco
- Department of Electrical Engineering, Chalmers University of Technology, 41296 Gothenburg, Sweden;
- MedTech West, Sahlgrenska University Hospital, 41345 Gothenburg, Sweden
- Correspondence:
| | - Lars Peterson
- Sahlgrenska Academy, University of Gothenburg, 40530 Gothenburg, Sweden;
| | - Andreas Fhager
- Department of Electrical Engineering, Chalmers University of Technology, 41296 Gothenburg, Sweden;
- MedTech West, Sahlgrenska University Hospital, 41345 Gothenburg, Sweden
| |
Collapse
|
24
|
Qian W, Qian C. Long-Range Detection of a Wirelessly Powered Resistive Transducer. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT 2022; 71:9507109. [PMID: 39086936 PMCID: PMC11290552 DOI: 10.1109/tim.2022.3178475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 08/02/2024]
Abstract
Wireless measurement of resistance variation is particularly desirable inside confined cavities where wire connection and battery replacement are undesirable. Compared to capacitive or inductive transducers, resistive transducers have better availability, whose resistance changes can be directly converted into detectable voltages by electric bridges. However, to wirelessly operate electric bridges on batteryless platforms, multistage circuits are required to convert dc signals into wireless signals, making the whole system hard to miniaturize without using complicated integrated circuits. Alternatively, resistive transducers can be incorporated into passive L C resonators for contactless characterization by the backscattering method. This design, however, is ineffective beyond the near field, and it requires complicated line shape analysis of resonators' frequency response curves. Here, we will significantly improve the remote detectability of a resistive transducer, by inductively coupling it with a parametric resonator. Upon activation by wireless pumping power with an external antenna, the parametric resonator can self-oscillate and emit strong oscillation signals. The temperature-induced resistance change is converted into linear frequency shifts of the oscillation signal that can be detected over large distance separations for up to 20-fold the sensor's own dimension. Every 0.1 °C of temperature change can be converted into 8 kHz of frequency shift that is approximately threefold larger than the linewidth of oscillation peak. This sensor maintains good linearity between 25 °C and 41 °C, providing enough range for physiological monitoring. In conclusion, we have fabricated a resistance-to-frequency converter for remote detection of resistance changes via a wirelessly powered parametric oscillator. Besides this proof-of-concept demonstration for temperature sensing, the general concept of resistance-to-frequency conversion will improve the remote detectability of a broad range of resistive transducers for physiological and environmental monitoring.
Collapse
Affiliation(s)
- Wei Qian
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824 USA
| | - Chunqi Qian
- Department of Radiology, Michigan State University, East Lansing, MI 48824 USA
| |
Collapse
|
25
|
Nazemorroaya A, Aghaeifar A, Shiozawa T, Hirt B, Schulz H, Scheffler K, Hagberg GE. Developing formalin-based fixative agents for post mortem brain MRI at 9.4 T. Magn Reson Med 2021; 87:2481-2494. [PMID: 34931721 DOI: 10.1002/mrm.29122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 11/24/2021] [Accepted: 11/25/2021] [Indexed: 11/07/2022]
Abstract
PURPOSE To develop fixative agents for high-field MRI with suitable dielectric properties and measure MR properties in immersion-fixed brain tissue. METHODS Dielectric properties of formalin-based agents were assessed (100 MHz-4.5 GHz), and four candidate fixatives with/without polyvinylpyrrolidone (PVP) and different salt concentrations were formulated. B1 field and MR properties (T1 , R 2 ∗ , R2 , R 2 ' , and magnetic susceptibility [QSM]) were observed in white and gray matter of pig brain samples during 0.5-35 days of immersion fixation. The kinetics were fitted using exponential functions. The immersion time required to reach maximum R 2 ∗ values at different tissue depths was used to estimate the Medawar coefficient for fixative penetration. The effect of replacing the fixatives with Fluoroinert and phosphate-buffered saline as embedding media was also evaluated. RESULTS The dielectric properties of formalin were nonlinearly modified by increasing amounts of additives. With 5% PVP and 0.04% NaCl, the dielectric properties and B1 field reflected in vivo conditions. The highest B1 values were found in white matter with PVP and varied significantly with tissue depth and embedding media, but not with immersion time. The MR properties depended on PVP yielding lower T1 , higher R 2 ∗ , more paramagnetic QSM values, and a lower Medawar coefficient (0.9 mm / h ; without PVP: 1.5). Regardless of fixative, switching to phosphate-buffered saline as embedder caused a paramagnetic shift in QSM and decreased R 2 ∗ that progressed during 1 month of storage, whereas no differences were found with Fluorinert. CONCLUSION In vivo-like B1 fields can be achieved in formalin fixatives using PVP and a low salt concentration, yielding lower T1 , higher R 2 ∗ , and more paramagnetic QSM than without additives. The kinetics of R 2 ∗ allowed estimation of fixative tissue penetration.
Collapse
Affiliation(s)
- Azadeh Nazemorroaya
- High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Ali Aghaeifar
- High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Thomas Shiozawa
- Institute of Clinical Anatomy and Cell Analysis, Eberhard Karl's University of Tübingen, Tübingen, Germany
| | - Bernhard Hirt
- Institute of Clinical Anatomy and Cell Analysis, Eberhard Karl's University of Tübingen, Tübingen, Germany
| | - Hildegard Schulz
- High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Klaus Scheffler
- High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Institute of Biomedical Magnetic Resonance, Eberhard Karl's University of Tübingen, Tübingen, Germany
| | - Gisela E Hagberg
- High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Institute of Biomedical Magnetic Resonance, Eberhard Karl's University of Tübingen, Tübingen, Germany
| |
Collapse
|
26
|
Gilbert KM, Dubovan PI, Gati JS, Menon RS, Baron CA. Integration of an RF coil and commercial field camera for ultrahigh-field MRI. Magn Reson Med 2021; 87:2551-2565. [PMID: 34932225 DOI: 10.1002/mrm.29130] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 11/16/2021] [Accepted: 12/03/2021] [Indexed: 11/08/2022]
Abstract
PURPOSE To develop an RF coil with an integrated commercial field camera for ultrahigh field (7T) neuroimaging. The RF coil would operate within a head-only gradient coil and be subject to the corresponding design constraints. The RF coil can thereafter be used for subject-specific correction of k-space trajectories-notably in gradient-sensitive sequences such as single-shot spiral imaging. METHODS The transmit and receive performance was evaluated before and after the integration of field probes, whereas field probes were evaluated when in an optimal configuration external to the coil and after their integration. Diffusion-weighted EPI and single-shot spiral acquisitions were employed to evaluate the efficacy of correcting higher order field perturbations and the consequent effect on image quality. RESULTS Field probes had a negligible effect on RF-coil performance, including the transmit efficiency, transmit uniformity, and mean SNR over the brain. Modest reductions in field-probe signal lifetimes were observed, caused primarily by nonidealities in the gradient and shim fields of the head-only gradient coil at the probe positions. The field-monitoring system could correct up to second-order field perturbations in single-shot spiral imaging. CONCLUSION The integrated RF coil and field camera was capable of concurrent-field monitoring within a 7T head-only scanner and facilitated the subsequent correction of k-space trajectories during spiral imaging.
Collapse
Affiliation(s)
- Kyle M Gilbert
- Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, Ontario, Canada.,Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| | - Paul I Dubovan
- Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, Ontario, Canada.,Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| | - Joseph S Gati
- Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, Ontario, Canada.,Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| | - Ravi S Menon
- Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, Ontario, Canada.,Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| | - Corey A Baron
- Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, Ontario, Canada.,Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| |
Collapse
|
27
|
Zia G, Sebek J, Prakash P. Temperature-dependent dielectric properties of human uterine fibroids over microwave frequencies. Biomed Phys Eng Express 2021; 7. [PMID: 34534970 DOI: 10.1088/2057-1976/ac27c2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2021] [Accepted: 09/17/2021] [Indexed: 12/15/2022]
Abstract
Microwave ablation is under investigation as a minimally-invasive treatment for uterine fibroids. Computational models play a vital role in the development, evaluation and characterization of candidate ablation devices. The temperature-dependent dielectric properties of fibroid tissue are essential for accurate computational modeling.Objective:To measure the broadband temperature-dependent dielectric properties of uterine fibroids excised during hysterectomy procedures.Methods: The open-ended coaxial probe method was employed for measuring the broadband dielectric properties of freshly excised human uterine fibroid samples (n = 6) obtained from an IRB-approved tissue bank. The dielectric properties (relative permittivity,εr, and effective electrical conductivity,σeff) were evaluated at temperatures ranging from 23 °C-150 °C, over the frequency range of 0.5-6 GHz. Linear piecewise parametrization with respect to temperature and quadratic parametrization with respect to frequency was applied to characterize broadband temperature-dependent dielectric properties of fibroid tissue.Results: The baseline room temperature values ofεrvary from 57.5 ± 5.29 to 44.5 ± 5.77 units andσeffchanges from 0.91 ± 0.19 to 6.02 ± 0.7 S m-1over the frequency range of 0.5-6 GHz. At temperatures close to the water vaporization point,εr, drops considerably i.e. to 12%-14% of its baseline value for all measured frequencies.σeffvalues initially rise till 98 °C and then fall to 11%-13% of their baseline values at 125 °C for frequencies ≤2.45 GHz. Theσefffollows a decreasing trend for frequencies >2.45 GHz and drops to ∼6 % of their baseline room temperature values.Conclusion:The temperature dependent dielectric properties of uterine fibroid tissues over microwave frequency range are reported for the first time in this study. Parametric models of uterine fibroid dielectric properties are also presented for incorporation within computational models of microwave ablation of fibroids.
Collapse
Affiliation(s)
- Ghina Zia
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS, United States of America
| | - Jan Sebek
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS, United States of America.,Department of Circuit Theory, Czech Technical University in Prague, Prague, Czech Republic
| | - Punit Prakash
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS, United States of America
| |
Collapse
|
28
|
Dobšíček Trefná H, Llàcer Navarro S, Lorentzon F, Nypelö T, Ström A. Fat tissue equivalent phantoms for microwave applications by reinforcing gelatin with nanocellulose. Biomed Phys Eng Express 2021; 7. [PMID: 34517355 DOI: 10.1088/2057-1976/ac2634] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Accepted: 09/13/2021] [Indexed: 11/12/2022]
Abstract
Tissue mimicking phantom materials with thermal and dielectric equivalence are vital for the development of microwave diagnostics and treatment. The current phantoms representing fat tissue are challenged by mechanical integrity at relevant temperatures coupled with complex production protocols. We have employed two types of nanocellulose (cellulose nanocrystals and oxidized cellulose nanocrystals) as reinforcement in gelatin stabilized emulsions for mimicking fat tissue. The nanocellulose-gelatin stabilized emulsions were evaluated for their dielectric properties, the moduli-temperature dependence using small deformation rheology, stress-strain behavior using large deformation, and their compliance to quality assurance guidelines for superficial hyperthermia. All emulsions had low permittivity and conductivity within the lower microwave frequency band, accompanied by fat equivalent thermal properties. Small deformation rheology showed reduced temperature dependence of the moduli upon addition of nanocellulose, independent of type. The cellulose nanocrystals gelatin reinforced emulsion complied with the quality assurance guidelines. Hence, we demonstrate that the addition of cellulose nanocrystals to gelatin stabilized emulsions has the potential to be used as fat phantoms for the development of microwave diagnostics and treatment.
Collapse
Affiliation(s)
- Hana Dobšíček Trefná
- Signal Processing and Biomedical engineering, Department of Electrical Engineering, Chalmers University of Technology, Sweden
| | - Saül Llàcer Navarro
- Applied Chemistry, Department of Chemistry and Chemical Engineering, Chalmers University of Technology, Sweden.,Wallenberg Wood Science Center, Chalmers University of Technology, Sweden
| | - Fredrik Lorentzon
- Signal Processing and Biomedical engineering, Department of Electrical Engineering, Chalmers University of Technology, Sweden.,Applied Chemistry, Department of Chemistry and Chemical Engineering, Chalmers University of Technology, Sweden
| | - Tiina Nypelö
- Applied Chemistry, Department of Chemistry and Chemical Engineering, Chalmers University of Technology, Sweden.,Wallenberg Wood Science Center, Chalmers University of Technology, Sweden
| | - Anna Ström
- Applied Chemistry, Department of Chemistry and Chemical Engineering, Chalmers University of Technology, Sweden
| |
Collapse
|
29
|
Motovilova E, Tan ET, Taracila V, Vincent JM, Grafendorfer T, Shin J, Potter HG, Robb FJL, Sneag DB, Winkler SA. Stretchable self-tuning MRI receive coils based on liquid metal technology (LiquiTune). Sci Rep 2021; 11:16228. [PMID: 34376703 PMCID: PMC8355233 DOI: 10.1038/s41598-021-95335-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Accepted: 07/23/2021] [Indexed: 01/14/2023] Open
Abstract
Magnetic resonance imaging systems rely on signal detection via radiofrequency coil arrays which, ideally, need to provide both bendability and form-fitting stretchability to conform to the imaging volume. However, most commercial coils are rigid and of fixed size with a substantial mean offset distance of the coil from the anatomy, which compromises the spatial resolution and diagnostic image quality as well as patient comfort. Here, we propose a soft and stretchable receive coil concept based on liquid metal and ultra-stretchable polymer that conforms closely to a desired anatomy. Moreover, its smart geometry provides a self-tuning mechanism to maintain a stable resonance frequency over a wide range of elongation levels. Theoretical analysis and numerical simulations were experimentally confirmed and demonstrated that the proposed coil withstood the unwanted frequency detuning typically observed with other stretchable coils (0.4% for the proposed coil as compared to 4% for a comparable control coil). Moreover, the signal-to-noise ratio of the proposed coil increased by more than 60% as compared to a typical, rigid, commercial coil.
Collapse
Affiliation(s)
- Elizaveta Motovilova
- grid.5386.8000000041936877XDepartment of Radiology, Weill Cornell Medicine, New York, NY 10065 USA ,grid.239915.50000 0001 2285 8823Department of Radiology, Hospital for Special Surgery, New York, NY 10021 USA
| | - Ek Tsoon Tan
- grid.239915.50000 0001 2285 8823Department of Radiology, Hospital for Special Surgery, New York, NY 10021 USA
| | - Victor Taracila
- grid.418143.b0000 0001 0943 0267GE Healthcare, Aurora, OH USA
| | - Jana M. Vincent
- grid.418143.b0000 0001 0943 0267GE Healthcare, Aurora, OH USA
| | | | - James Shin
- grid.5386.8000000041936877XDepartment of Radiology, Weill Cornell Medicine, New York, NY 10065 USA
| | - Hollis G. Potter
- grid.239915.50000 0001 2285 8823Department of Radiology, Hospital for Special Surgery, New York, NY 10021 USA
| | | | - Darryl B. Sneag
- grid.239915.50000 0001 2285 8823Department of Radiology, Hospital for Special Surgery, New York, NY 10021 USA
| | - Simone A. Winkler
- grid.5386.8000000041936877XDepartment of Radiology, Weill Cornell Medicine, New York, NY 10065 USA
| |
Collapse
|
30
|
Woletz M, Roat S, Hummer A, Tik M, Windischberger C. Technical Note: Human tissue-equivalent MRI phantom preparation for 3 and 7 Tesla. Med Phys 2021; 48:4387-4394. [PMID: 34018625 DOI: 10.1002/mp.14986] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 03/31/2021] [Accepted: 05/07/2021] [Indexed: 12/22/2022] Open
Abstract
PURPOSE While test objects (phantoms) in magnetic resonance imaging (MRI) are crucial for sequence development, protocol validation, and quality control, studies on the preparation of phantoms have been scarce, particularly at fields exceeding 3 Tesla. Here, we present a framework for the preparation of phantoms with well-defined T1 and T2 times at 3 and 7 Tesla. METHODS Phantoms with varying concentrations of agarose and Gd-DTPA were prepared and measured at 3 and 7 Tesla using T1 and T2 mapping techniques. An empirical, polynomial model was constructed that best represents the data at both field strengths, enabling the preparation of new phantoms with specified combinations of both T1 and T2 . Instructions for three different tissue types (brain gray matter, brain white matter, and renal cortex) are presented and validated. RESULTS T1 times in the samples ranged from 698 to 2820 ms and from 695 to 2906 ms, whereas T2 times ranged from 39 to 227 ms and from 34 to 235 ms for 3 and 7 Tesla scans, respectively. Models for both relaxation times used six parameters to represent the data with an adjusted R² of 0.998 and 0.997 for T1 and T2 , respectively. CONCLUSION Based on the equations derived from the current study, it is now possible to obtain accurate weight specifications for a test object with desired T1 and T2 relaxation times. This will spare researchers the laborious task of trail-and-error approaches in test object preparation attempts.
Collapse
Affiliation(s)
- Michael Woletz
- High-field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Sigrun Roat
- High-field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Allan Hummer
- High-field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Martin Tik
- High-field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Christian Windischberger
- High-field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Währinger Gürtel 18-20, Vienna, 1090, Austria
| |
Collapse
|
31
|
Lakshmanan K, Carluccio G, Walczyk J, Brown R, Rupprecht S, Yang QX, Lanagan MT, Collins CM. Improved whole-brain SNR with an integrated high-permittivity material in a head array at 7T. Magn Reson Med 2021; 86:1167-1174. [PMID: 33755236 DOI: 10.1002/mrm.28780] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 03/03/2021] [Accepted: 03/04/2021] [Indexed: 12/12/2022]
Abstract
PURPOSE To demonstrate that strategic use of materials with high electric permittivity along with integrated head-sized coil arrays can improve SNR in the entire brain. METHODS Numerical simulations were used to design a high-permittivity material (HPM) helmet for enhancing SNR throughout the brain in receive arrays of 8 and 28 channels. Then, two 30-channel head coils of identical geometry were constructed: one fitted with a prototype helmet-shaped ceramic HPM helmet, and the second with a helmet-shaped low-permittivity shell, each 8-mm thick. An eight-channel dipole array was used for excitation. In vivo maps of excitation flip angle and SNR were acquired. RESULTS Simulation results showed improvement in transmit efficiency by up to 65% and in receive-side SNR by up to 47% on average through the head with use of an HPM helmet. Experimental results showed that experimental transmit efficiency was improved by approximately 56% at the center of brain, and experimental receive-side SNR (SNR normalized to flip angle) was improved by approximately 21% on average through orthogonal planes through the cerebrum, including at the center of the brain, with the HPM. CONCLUSION Although HPM is used increasingly to improve transmit efficiency locally in situations in which the transmit coil and imaging volume are much larger than the HPM, here we demonstrate that HPM can also be used to improve transmit efficiency and receive-side SNR throughout the brain by improving performance of a head-sized receive array. This includes the center of the brain, where it is difficult to improve SNR by other means.
Collapse
Affiliation(s)
- Karthik Lakshmanan
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University School of Medicine, New York, New York, USA
| | - Giuseppe Carluccio
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University School of Medicine, New York, New York, USA
| | - Jerzy Walczyk
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University School of Medicine, New York, New York, USA
| | - Ryan Brown
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University School of Medicine, New York, New York, USA.,The Sackler Institute of Graduate Biomedical Science, New York, New York, USA
| | | | | | | | - Christopher M Collins
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University School of Medicine, New York, New York, USA.,The Sackler Institute of Graduate Biomedical Science, New York, New York, USA
| |
Collapse
|
32
|
Gilbert KM, Klassen LM, Mashkovtsev A, Zeman P, Menon RS, Gati JS. Radiofrequency coil for routine ultra-high-field imaging with an unobstructed visual field. NMR IN BIOMEDICINE 2021; 34:e4457. [PMID: 33305466 DOI: 10.1002/nbm.4457] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Accepted: 11/17/2020] [Indexed: 06/12/2023]
Abstract
Many neuroscience applications have adopted functional MRI as a tool to investigate the healthy and diseased brain during the completion of a task. While ultra-high-field MRI has allowed for improved contrast and signal-to-noise ratios during functional MRI studies, it remains a challenge to create local radiofrequency coils that can accommodate an unobstructed visual field and be suitable for routine use, while at the same time not compromise performance. Performance (both during transmission and reception) can be improved by using close-fitting coils; however, maintaining sensitivity over the whole brain often requires the introduction of coil elements proximal to the eyes, thereby partially occluding the subject's visual field. This study presents a 7 T head coil, with eight transmit dipoles and 32 receive loops, that is designed to remove visual obstructions from the subject's line of sight, allowing for an unencumbered view of visual stimuli, the reduction of anxiety induced from small enclosures, and the potential for eye-tracking measurements. The coil provides a practical solution for routine imaging, including a split design (anterior and posterior halves) that facilitates subject positioning, including those with impaired mobility, and the placement of devices required for patient comfort and motion reduction. The transmit and receive coils displayed no degradation of performance due to adaptions to the design topology (both mechanical and electrical) required to create an unobstructed visual field. All computer-aided design files, electromagnetic simulation models, transmit field maps and local specific absorption rate matrices are provided to promote reproduction.
Collapse
Affiliation(s)
- Kyle M Gilbert
- Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, Ontario, Canada
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| | - L Martyn Klassen
- Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, Ontario, Canada
| | - Alexander Mashkovtsev
- Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, Ontario, Canada
| | - Peter Zeman
- Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, Ontario, Canada
| | - Ravi S Menon
- Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, Ontario, Canada
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| | - Joseph S Gati
- Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, Ontario, Canada
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| |
Collapse
|
33
|
Dorst J, Ruhm L, Avdievich N, Bogner W, Henning A. Comparison of four 31P single-voxel MRS sequences in the human brain at 9.4 T. Magn Reson Med 2021; 85:3010-3026. [PMID: 33427322 DOI: 10.1002/mrm.28658] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 12/03/2020] [Accepted: 12/06/2020] [Indexed: 01/30/2023]
Abstract
PURPOSE In this study, different single-voxel localization sequences were implemented and systematically compared for the first time for phosphorous MRS (31 P-MRS) in the human brain at 9.4 T. METHODS Two multishot sequences, image-selected in vivo spectroscopy (ISIS) and a conventional slice-selective excitation combined with localization by adiabatic selective refocusing (semiLASER) variant of the spin-echo full intensity-acquired localized spectroscopy (SPECIAL-semiLASER), and two single-shot sequences, semiLASER and stimulated echo acquisition mode (STEAM), were implemented and optimized for 31 P-MRS in the human brain at 9.4 T. Pulses and coil setup were optimized, localization accuracy was tested in phantom experiments, and absolute SNR of the sequences was compared in vivo. The SNR per unit time (SNR/t) was derived and compared for all four sequences and verified experimentally for ISIS in two different voxel sizes (3 × 3 × 3 cm3 , 5 × 5 × 5 cm3 , 10-minute measurement time). Metabolite signals obtained with ISIS were quantified. The possible spectral quality in vivo acquired in clinically feasible time (3:30 minutes, 3 × 3 × 3 cm3 ) was explored for two different coil setups. RESULTS All evaluated sequences performed with good localization accuracy in phantom experiments and provided well-resolved spectra in vivo. However, ISIS has the lowest chemical shift displacement error, the best localization accuracy, the highest SNR/t for most metabolites, provides metabolite concentrations comparable to literature values, and is the only one of the sequences that allows for the detection of the whole 31 P spectrum, including β-adenosine triphosphate, with the used setup. The SNR/t of STEAM is comparable to the SNR/t of ISIS. The semiLASER and SPECIAL-semiLASER sequences provide good results for metabolites with long T2 . CONCLUSION At 9.4 T, high-quality single-voxel localized 31 P-MRS can be performed in the human brain with different localization methods, each with inherent characteristics suitable for different research issues.
Collapse
Affiliation(s)
- Johanna Dorst
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,IMPRS for Cognitive and Systems Neuroscience, University of Tübingen, Tübingen, Germany
| | - Loreen Ruhm
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,IMPRS for Cognitive and Systems Neuroscience, University of Tübingen, Tübingen, Germany
| | - Nikolai Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Wolfgang Bogner
- High-Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Anke Henning
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas, USA
| |
Collapse
|
34
|
Jona G, Furman‐Haran E, Schmidt R. Realistic head-shaped phantom with brain-mimicking metabolites for 7 T spectroscopy and spectroscopic imaging. NMR IN BIOMEDICINE 2021; 34:e4421. [PMID: 33015864 PMCID: PMC7757235 DOI: 10.1002/nbm.4421] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Revised: 08/30/2020] [Accepted: 09/14/2020] [Indexed: 06/11/2023]
Abstract
PURPOSE Moving to ultra-high fields (≥7 T), the inhomogeneity of both RF (B1 ) and static (B0 ) magnetic fields increases, which further motivates us to design a realistic head-shaped phantom, especially for spectroscopic imaging. Such phantoms provide images similar to the human brain and serve as a reliable tool for developing and examining methods in MRI. This study aims to develop and characterize a realistic head-shaped phantom filled with brain-mimicking metabolites for MRS and magnetic resonance spectroscopic imaging in a 7 T MRI scanner. METHODS A 3D head-shaped container with three sections-mimicking brain, muscle and precranial lipid-was constructed. The phantom was designed to provide robustness to heating, mechanical damage and leakage, with easy refilling. The head's shape and the agarose mixture were optimized to provide B0 and B1 distributions and T1 /T2 relaxation values similar to those of human brain. Eight brain-tissue-mimicking metabolites were included for spectroscopy. The phantom was evaluated for localized spectroscopy, fast spectroscopic imaging and fat suppression. RESULTS The B0 and B1 maps showed distribution similar to that of human brain, with increased B0 inhomogeneity near the nasal and ear areas and reduced B1 in the temporal lobe and brain stem regions, as expected in vivo. The metabolites' concentrations were verified by single-voxel spectroscopy, showing an average deviation of 11%. Fast spectroscopic imaging and imaging with fat suppression were demonstrated. CONCLUSION A 3D head-shaped phantom for human brain imaging and spectroscopic imaging in 7 T MRI was demonstrated, making it a realistic phantom for methodology development at 7 T.
Collapse
Affiliation(s)
- Ghil Jona
- Life Sciences Core FacilitiesWeizmann Institute of ScienceRehovotIsrael
| | - Edna Furman‐Haran
- Life Sciences Core FacilitiesWeizmann Institute of ScienceRehovotIsrael
- The Azrieli National Institute for Human Brain Imaging and ResearchWeizmann Institute of ScienceRehovotIsrael
| | - Rita Schmidt
- The Azrieli National Institute for Human Brain Imaging and ResearchWeizmann Institute of ScienceRehovotIsrael
- Neurobiology DepartmentWeizmann Institute of ScienceRehovotIsrael
| |
Collapse
|
35
|
Fagan AJ, Jacobs PS, Hulshizer TC, Rossman PJ, Frick MA, Amrami KK, Felmlee JP. 7T MR Thermometry technique for validation of system-predicted SAR with a home-built radiofrequency wrist coil. Med Phys 2020; 48:781-790. [PMID: 33294999 DOI: 10.1002/mp.14641] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Revised: 11/03/2020] [Accepted: 11/30/2020] [Indexed: 11/12/2022] Open
Abstract
PURPOSE A 7T magnetic resonance thermometry (MRT) technique was developed to validate the conversion factor between the system-measured transmitted radiofrequency (RF) power into a home-built RF wrist coil with the system-predicted SAR value. The conversion factor for a new RF coil developed for ultra high magnetic field MRI systems is used to ensure that regulatory limits on RF energy deposition in tissue, specifically the local 10g-averaged specific absorption rate (SAR10g ), are not exceeded. MRT can be used to validate this factor by ensuring that MRT-measured SAR values do not exceed those predicted by the system. METHODS A 14-cm diameter high-pass birdcage RF coil was built to image the wrist at 7T. A high spatial and temporal resolution dual-echo gradient echo MRT technique, incorporating quasi-simultaneous RF-induced heating and temperature change measurements using the proton resonance frequency method, was developed. The technique allowed for high-temperature resolution measurements (~±0.1°C) to be performed every 20 s over a 4-min heating period, with high spatial resolution (2.56 mm3 voxel size) and avoiding phase discontinuities arising from severe magnetic susceptibility-induced B0 inhomogeneities. Magnetic resonance thermometry was performed on a phantom made from polyvinylpyrrolidone to mimic the dielectric properties of muscle tissue at 297.2 MHz. Temperature changes measured with MRT and four fiber optic temperature sensors embedded in the phantom were compared. Electromagnetic simulations of the coil and phantom were developed and validated via comparison of simulated and measured B1 + maps in the phantom. The position of maximum SAR within the coil was determined from simulations, and MRT was performed within a wrist-sized piece of meat positioned at that SAR hotspot location. MRT-measured and system-predicted SAR values for the phantom and meat were compared. RESULTS Temperature change measurements from MRT matched closely to those from the fiber optic temperature sensors. The simulations were validated via close correlation between the simulated and MRT-measured B1 + and SAR maps. Using a coil conversion factor of 2 kg-1 , MRT-measured point-SAR values did not exceed the system-predicted SAR10g in either the uniform phantom or in the piece of meat mimicking the wrist located at the SAR hotspot location. CONCLUSIONS A highly accurate MRT technique with high spatial and temporal resolution was developed. This technique can be used to ensure that system-predicted SAR values are not exceeded in practice, thereby providing independent validation of SAR levels delivered by a newly built RF wrist coil. The MRT technique is readily generalizable to perform safety evaluations for other RF coils at 7T.
Collapse
Affiliation(s)
- Andrew J Fagan
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Paul S Jacobs
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Thomas C Hulshizer
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Phillip J Rossman
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Matthew A Frick
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Kimberly K Amrami
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Joel P Felmlee
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| |
Collapse
|
36
|
Jeong H, Restivo MC, Jezzard P, Hess AT. Assessment of radio-frequency heating of a parallel transmit coil in a phantom using multi-echo proton resonance frequency shift thermometry. Magn Reson Imaging 2020; 77:57-68. [PMID: 33359425 PMCID: PMC7889491 DOI: 10.1016/j.mri.2020.12.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 11/27/2020] [Accepted: 12/20/2020] [Indexed: 10/25/2022]
Abstract
We propose a workflow for validating parallel transmission (pTx) radio-frequency (RF) magnetic field heating patterns using Proton-Resonance Frequency shift (PRF)-based MR thermometry. Electromagnetic (EM) and thermal simulations of a 7 T 8-channel dipole coil were done using commercially available software (Sim4Life) to assess RF heating. The fabrication method for a phantom with electrical properties matched to human tissue is also described, along with methods for its electrical and thermal characterisation. Energy was deposited to specific transmit channels, whilst acquiring 3D PRF data using a pair of interleaved RF shim transmit modes. A multi-echo readout and pre-scan stabilisation protocol were used for increased sensitivity and to correct for measurement-to-measurement instabilities. The electrical properties of the phantom were found to be within 10% of the intended values. Adoption of a 14-min stabilisation scan gave sufficient suppression of any evolving background spatial variation in the B0 field to achieve <0.001 °C/mm thermometry drift over 10 min of subsequent scanning. Using two RF shim transmit modes enabled full phantom coverage and combining multiple echo times enabled a 13-54% improvement in the RMSE sensitivity to temperature changes. Combining multiple echoes reduced the peak RMSE by 45% and visually reduced measurement-to-measurement instabilities. A reference fibre optic probe showed temperature deviations from the PRF-estimated temperature to be smaller than 0.5 °C. Given the importance of RF safety in pTx applications, this workflow enables accurate validation of RF heating simulations with minimal additional hardware requirements.
Collapse
Affiliation(s)
- Hongbae Jeong
- Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| | - Matthew C Restivo
- Laboratory of Imaging Technology, Biochemistry and Biophysics Centre, NHLBI, NIH, Bethesda, MD, United States
| | - Peter Jezzard
- Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Aaron T Hess
- Centre for Clinical Magnetic Resonance Research, Department of Cardiovascular Medicine, University of Oxford, Oxford, United Kingdom; British Heart Foundation Centre for Research Excellence, Oxford, United Kingdom.
| |
Collapse
|
37
|
Deng G, Cai L, Feng J, Duan S, Zhang P, Xin SX. Reliable Method for Fabricating Tissue-Mimicking Materials With Designated Relative Permittivity and Conductivity at 128 MHz. Bioelectromagnetics 2020; 42:86-94. [PMID: 33305868 DOI: 10.1002/bem.22303] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2019] [Accepted: 10/10/2020] [Indexed: 02/01/2023]
Abstract
Artificial materials that can simultaneously mimic the relative permittivity and conductivity of various human tissues are usually used in medical applications. However, the method of precisely designing these materials with designated values of both relative permittivity and conductivity at 3 T MRI resonance frequency is lacking. In this study, a reliable method is established to determine the compositions of artificial dielectric materials with designated relative permittivity and conductivity at 128 MHz. Sixty dielectric materials were produced using oil, sodium chloride, gelatin, and deionized water as the main raw materials. The dielectric properties of these dielectric materials were measured using the open-ended coaxial line method at 128 MHz. Nonlinear least-squares Marquardt-Levenberg algorithm was used to obtain the formula, establishing the relationship between the compositions of the dielectric materials and their dielectric properties at 128 MHz. The dielectric properties of the blood, gall bladder, muscle, skin, lung, and bone at 128 MHz were selected to verify the reliability of the obtained formula. For the obtained formula, the coefficient of determination and the expanded uncertainties with a coverage factor of k = 2 were 0.991% and 4.9% for relative permittivity and 0.992% and 6.4% for conductivity. For the obtained artificial materials measured using the open-ended coaxial line method, the maximal difference of relative permittivity and conductivity were 1.0 and 0.02 S/m, respectively, with respect to the designated values. In conclusion, the compositions of tissue-mimicking material can be quickly determined after the establishment of the formulas with the expanded uncertainties of less than 10%. Bioelectromagnetics. 2021;42:86-94. © 2020 Bioelectromagnetics Society.
Collapse
Affiliation(s)
- Guanhua Deng
- Department of Oncology, Guangdong Sanjiu Brain Hospital, Guangzhou, China
| | - Linbo Cai
- Department of Oncology, Guangdong Sanjiu Brain Hospital, Guangzhou, China
| | - Jian Feng
- Tongji Hospital, Huazhong University of Science and Technology, Wuhan, China
| | - Song Duan
- Department of Radiation Oncology, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Ping Zhang
- Department of Oncology, Guangdong Sanjiu Brain Hospital, Guangzhou, China
| | - Sherman X Xin
- School of Medicine, South China University of Technology, Guangzhou, China
| |
Collapse
|
38
|
Soullié P, Missoffe A, Ambarki K, Felblinger J, Odille F. MR electrical properties imaging using a generalized image-based method. Magn Reson Med 2020; 85:762-776. [PMID: 32783236 DOI: 10.1002/mrm.28458] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 07/08/2020] [Accepted: 07/10/2020] [Indexed: 11/12/2022]
Abstract
PURPOSE To develop a fast and easy-to-use electrical properties tomography (EPT) method based on a single MR scan, avoiding both the need of a B1 -map and transceive phase assumption, and that is robust against noise. THEORY Derived from Maxwell's equations, conductivity, and permittivity are reconstructed from a new partial differential equation involving the product of the RF fields and its derivatives. This also allows us to clarify and revisit the relevance of common assumptions of MREPT. METHODS Our new governing equation is solved using a 3D finite-difference scheme and compared to previous frameworks. The benefits of our method over selected existing MREPT methods are demonstrated for different simulation models, as well as for both an inhomogeneous agar phantom gel and in vivo brain data at 3T. RESULTS Simulation and experimental results are illustrated to highlight the merits of the proposed method over existing methods. We show the validity of our algorithm in versatile configurations, with many transition regions notably. Complex admittivity maps are also provided as a complementary MR contrast. CONCLUSION Because it avoids time-consuming RF field mapping and generalizes the use of standard MR image for electrical properties reconstruction, this contribution is promising as a new step forward for clinical applications.
Collapse
Affiliation(s)
- Paul Soullié
- IADI, INSERM U1254, Université de Lorraine, Nancy, France
| | | | | | - Jacques Felblinger
- IADI, INSERM U1254, Université de Lorraine, Nancy, France.,CIC-IT 1433, INSERM, Université de Lorraine and CHRU de Nancy, Nancy, France
| | - Freddy Odille
- IADI, INSERM U1254, Université de Lorraine, Nancy, France.,CIC-IT 1433, INSERM, Université de Lorraine and CHRU de Nancy, Nancy, France
| |
Collapse
|
39
|
Koreshin E, Efimtcev A, Gulko A, Popov S, Orlov I, Trufanov G, Zubkov M. Design of a RF-resonant set improving locally the B1+ efficiency. Applications for clinical MRI in andrology and urology. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 317:106774. [PMID: 32589584 DOI: 10.1016/j.jmr.2020.106774] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 05/25/2020] [Accepted: 06/13/2020] [Indexed: 06/11/2023]
Abstract
Modern diagnostic imaging methods for andrology and urology fall behind other well-developed applications such as cardiology or neurology. Particularly, MRI despite its superior soft tissue contrast is hardly used for MR-imaging of the penis, primarily due to the lack of the corresponding receive or transmit coils. In order to fix this, a new radio frequency resonator, based on the birdcage operating principles has been designed, simulated, fabricated, tested and compared experimentally to existing RF coils. In order to provide high transmit efficiency and high sensitivity, while maintaining the coil safety, the resonator spatially separates alternating magnetic and electric fields. The transmitted magnetic field (B1+) is concentrated in the centre of the imaging volume, while the electric field remains on its edge and does not lead to tissue heating. The resonator design was optimised for human MRI in 1.5 T scanners. Both simulations and experiment showed the resonator to provide around 100-fold specific absorption rate reduction, around 10-fold improvement of the transmit efficiency and more than 10-fold enhancement of the signal to noise ratio (SNR) in a phantom compared to the body coil, around 2-fold SNR enhancement in a phantom compared to the commercial flexible 4-element coil, and up to 1.5-fold enhancement compared to the same coil in-vivo.
Collapse
Affiliation(s)
- Eugene Koreshin
- ITMO University, Department of Physics and Engineering, 16 Birgevaya Line, St. Petersburg 199034, Russian Federation.
| | - Alexander Efimtcev
- Federal Almazov North West Medical Research, 2 Akkuratova Street, St. Petersburg 197341, Russian Federation.
| | - Alexander Gulko
- City Center of Endourology and New Technologies, 46 Chugunnaya Street, St. Petersburg 195009, Russian Federation.
| | - Sergey Popov
- City Center of Endourology and New Technologies, 46 Chugunnaya Street, St. Petersburg 195009, Russian Federation
| | - Igor Orlov
- City Center of Endourology and New Technologies, 46 Chugunnaya Street, St. Petersburg 195009, Russian Federation
| | - Gennady Trufanov
- Federal Almazov North West Medical Research, 2 Akkuratova Street, St. Petersburg 197341, Russian Federation.
| | - Mikhail Zubkov
- ITMO University, Department of Physics and Engineering, 16 Birgevaya Line, St. Petersburg 199034, Russian Federation.
| |
Collapse
|
40
|
Gudino N, de Zwart JA, Duyn JH. Eight-channel parallel transmit-receive system for 7 T MRI with optically controlled and monitored on-coil current-mode RF amplifiers. Magn Reson Med 2020; 84:3494-3501. [PMID: 32662913 DOI: 10.1002/mrm.28392] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Revised: 05/12/2020] [Accepted: 06/02/2020] [Indexed: 12/27/2022]
Abstract
PURPOSE To demonstrate a practical implementation of an eight-channel parallel-transmit system for brain imaging at 7 T based on on-coil amplifier technology. METHODS An eight-channel parallel transmit-receive system was built with optimized on-coil switch-mode current RF power amplifiers. The amplifiers were optically controlled from an eight-channel interface that was connected to a 7 T MRI scanner. The interface also optically received a down-converted version of the coil current sensed in each amplifier for monitoring and feedback adjustments. RESULTS Each on-coil amplifier delivered more than 100 W peak power and provided enough amplifier decoupling (<-15 dB) for the implemented eight-channel array configuration. Phantom and human images were acquired to demonstrate practical operation of this new technology in a 7 T MRI scanner. CONCLUSION Further development and improvement of previously demonstrated on-coil technology led to successful implementation of an eight-channel parallel-transmit system able to deliver strong B1 fields for typical brain imaging applications. This is an important step forward toward implementation of on-coil RF amplification for high-field MRI.
Collapse
Affiliation(s)
- Natalia Gudino
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA
| | - Jacco A de Zwart
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA
| | - Jeff H Duyn
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
41
|
Han H, Eigentler TW, Wang S, Kretov E, Winter L, Hoffmann W, Grass E, Niendorf T. Design, Implementation, Evaluation and Application of a 32-Channel Radio Frequency Signal Generator for Thermal Magnetic Resonance Based Anti-Cancer Treatment. Cancers (Basel) 2020; 12:cancers12071720. [PMID: 32605322 PMCID: PMC7408155 DOI: 10.3390/cancers12071720] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 06/21/2020] [Accepted: 06/22/2020] [Indexed: 12/13/2022] Open
Abstract
Thermal Magnetic Resonance (ThermalMR) leverages radio frequency (RF)-induced heating to examine the role of temperature in biological systems and disease. To advance RF heating with multi-channel RF antenna arrays and overcome the shortcomings of current RF signal sources, this work reports on a 32-channel modular signal generator (SGPLL). The SGPLL was designed around phase-locked loop (PLL) chips and a field-programmable gate array chip. To examine the system properties, switching/settling times, accuracy of RF power level and phase shifting were characterized. Electric field manipulation was successfully demonstrated in deionized water. RF heating was conducted in a phantom setup using self-grounded bow-tie RF antennae driven by the SGPLL. Commercial signal generators limited to a lower number of RF channels were used for comparison. RF heating was evaluated with numerical temperature simulations and experimentally validated with MR thermometry. Numerical temperature simulations and heating experiments controlled by the SGPLL revealed the same RF interference patterns. Upon RF heating similar temperature changes across the phantom were observed for the SGPLL and for the commercial devices. To conclude, this work presents the first 32-channel modular signal source for RF heating. The large number of coherent RF channels, wide frequency range and accurate phase shift provided by the SGPLL form a technological basis for ThermalMR controlled hyperthermia anti-cancer treatment.
Collapse
Affiliation(s)
- Haopeng Han
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), 13125 Berlin, Germany; (H.H.); (T.W.E.); (E.K.)
- Humboldt-Universität zu Berlin, Institute of Computer Science, 10099 Berlin, Germany;
| | - Thomas Wilhelm Eigentler
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), 13125 Berlin, Germany; (H.H.); (T.W.E.); (E.K.)
- Technische Universität Berlin, Chair of Medical Engineering, 10623 Berlin, Germany
| | - Shuailin Wang
- Beijing Deepvision Technology Co., Ltd., Beijing 100085, China;
| | - Egor Kretov
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), 13125 Berlin, Germany; (H.H.); (T.W.E.); (E.K.)
| | - Lukas Winter
- Physikalisch-Technische Bundesanstalt (PTB), 10587 Berlin, Germany; (L.W.); (W.H.)
| | - Werner Hoffmann
- Physikalisch-Technische Bundesanstalt (PTB), 10587 Berlin, Germany; (L.W.); (W.H.)
| | - Eckhard Grass
- Humboldt-Universität zu Berlin, Institute of Computer Science, 10099 Berlin, Germany;
- IHP—Leibniz-Institut für innovative Mikroelektronik, 15236 Frankfurt (Oder), Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), 13125 Berlin, Germany; (H.H.); (T.W.E.); (E.K.)
- Experimental and Clinical Research Center (ECRC), a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine, 13125 Berlin, Germany
- MRI.TOOLS GmbH, 13125 Berlin, Germany
- Correspondence: ; Tel.: +49-30-9406-4505
| |
Collapse
|
42
|
Vincent JM, Rispoli JV. Stitching Stretchable Radiofrequency Coils for MRI: A Conductive Thread and Athletic Fabric Approach .. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:6798-6801. [PMID: 31947401 DOI: 10.1109/embc.2019.8857051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE We propose a novel flexible and entirely stretchable radiofrequency coil for magnetic resonance imaging. This coil design aims at increasing patient comfort during joint imaging while maintaining or improving image quality. METHODS Conductive silver-coated thread was stitched in a zigzag pattern onto stretchable athletic fabric to create a single-loop receive coil. The stitched coil was mounted in a draped and stretched fashion and compared to a coil fabricated on flexible printed circuit board. Match/tune circuits, detuning circuits, and baluns were incorporated into the final setup for bench measurements and imaging on a 3T MR scanner. A fast spin echo sequence was used to obtain images for comparison. RESULTS The fabricated coil presents multi-directional stretchability and flexibility while maintaining conductivity and stitch integrity. Quality factor measurements and SNR calculations show that this stretchable coil design is comparable to a flexible, standard PCB coil. Detailed human wrist images were successfully obtained in vivo using the stretched, stitched coil. CONCLUSION The resulting MR images and SNR calculations support further experimentation into more complex coil geometries. SIGNIFICANCE This coil is uniquely stretchable in all direction and allows for joint imaging at various degrees of flexion. Additionally, this coil offers the closest proximity of placement to the skin with materials that provide a similar level of comfort to that of athletic wear and compression sleeves. This stitched design could be incorporated into coils for a variety of anatomies.
Collapse
|
43
|
Zhao Y, Shan T, Chi Z, Jiang H. Thermoacoustic tomography of germinal matrix hemorrhage in neonatal mouse cerebrum. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2020; 28:83-93. [PMID: 31771088 DOI: 10.3233/xst-190599] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
BACKGROUND Microwave-induced thermoacoustic tomography (TAT) has potential for detecting germinal matrix hemorrhage (GMH). However, it has not been demonstrated in vivo. OBJECTIVE To demonstrate the feasibility of TAT for in vivo detecting GMH by using neonatal mouse. METHODS A cylindrical-scanning TAT system was developed with optimized microwave irradiation and ultrasound detection for neonatal mouse imaging. Neonatal mice were used to develop GMH model by injection of autologous blood into the periventricular region. After TAT experiments, the animals were sacrificed, frozen and excised to validate the TAT findings. The detailed comparative analyses of the TAT images and corresponding photographs of the excised brain tissues were conducted. RESULTS Satisfactory matches are identified between the TAT images and corresponding histological sections, in terms of the shape and size of the brain tissues. Some organs and tissues were also identified. Particularly, comparing to the corresponding histological sections, using TAT enables to more accurately detect the hematoma region at different depths in the neonatal mouse brain. CONCLUSIONS This study demonstrates for the first time that TAT can detect GMH in neonatal mouse cerebrum in vivo. This represents the first important step towards the in vivo diagnosis and grading of hemorrhage in the infant human brain.
Collapse
Affiliation(s)
- Yuan Zhao
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, China
- Center for Information in Medicine, University of Electronic Science and Technology of China Chengdu, China
| | - Tianqi Shan
- Department of Biomedical Engineering, University of Florida, Gainesville, Florida, USA
| | - Zihui Chi
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, China
- Center for Information in Medicine, University of Electronic Science and Technology of China Chengdu, China
| | - Huabei Jiang
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, China
- Center for Information in Medicine, University of Electronic Science and Technology of China Chengdu, China
- Department of Medical Engineering, University of South Florida, Tampa, Florida, USA
| |
Collapse
|
44
|
Vincent JM, Rispoli JV. Conductive Thread-Based Stretchable and Flexible Radiofrequency Coils for Magnetic Resonance Imaging. IEEE Trans Biomed Eng 2019; 67:2187-2193. [PMID: 31794385 DOI: 10.1109/tbme.2019.2956682] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE We propose a novel flexible and entirely stretchable radiofrequency coil for magnetic resonance imaging. This coil design aims at increasing patient comfort during imaging while maintaining or improving image quality. METHODS Conductive silver-coated thread was zigzag stitched onto stretchable athletic fabric to create a single-loop receive coil. The stitched coil was mounted in draped and stretched fashions and compared to a coil fabricated on flexible printed circuit board. Match/tune circuits, detuning circuits, and baluns were incorporated into the final setup for bench measurements and imaging on a 3T MR scanner. A fast spin echo sequence was used to obtain images for comparison. RESULTS The fabricated coil presents multi-directional stretchability and flexibility while maintaining conductivity and stitch integrity. SNR calculations show that this stretchable coil design is comparable to a flexible, standard PCB coil with a 13-30% decrease in SNR depending on stretch degree and direction. In vivo human wrist images were obtained using the stitched coil. CONCLUSION Despite the reduction in SNR for this combination of materials, there is a reduced percentage of SNR drop as compared to existing stretch coil designs. These imaging results and calculations support further experimentation into more complex coil geometries. SIGNIFICANCE This coil is uniquely stretchable in all directions, allowing for joint imaging at various degrees of flexion, while offering the closest proximity of placement to the skin. The materials provide a similar level of comfort to athletic wear and could be incorporated into coils for a variety of anatomies.
Collapse
|
45
|
Arteaga-Marrero N, Villa E, González-Fernández J, Martín Y, Ruiz-Alzola J. Polyvinyl alcohol cryogel phantoms of biological tissues for wideband operation at microwave frequencies. PLoS One 2019; 14:e0219997. [PMID: 31344092 PMCID: PMC6657873 DOI: 10.1371/journal.pone.0219997] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Accepted: 07/05/2019] [Indexed: 11/18/2022] Open
Abstract
The aim of this work is to provide a methodology to model the dielectric properties of human tissues based on phantoms prepared with an aqueous solution, in a semi-solid form, by using off-the-shelf components. Polyvinyl alcohol cryogel (PVA-C) has been employed as a novel gelling agent in the fabrication of phantoms for microwave applications in a wide frequency range, from 500 MHz to 20 GHz. Agar-based and deionized water phantoms have also been manufactured for comparison purposes. Mathematical models dependent on frequency and sucrose concentration are proposed to obtain the complex permittivity of the desired mimicked tissues. These models have been validated in the referred bandwidth showing a good agreement to experimental data for different sucrose concentrations. The PVA-C model provides a great performance as compared to agar, increasing the shelf-life of the phantoms and improving their consistency for contact-required devices. In addition, the feasibility of fabricating a multilayer phantom has been demonstrated with a two-layer phantom that exhibits a clear interface between each layer and its properties. Thus, the use of PVA-C extends the option for producing complex multilayer and multimodal phantoms.
Collapse
Affiliation(s)
- Natalia Arteaga-Marrero
- IACTec Medical Technology Group, Instituto de Astrofísica de Canarias (IAC), La Laguna, Santa Cruz de Tenerife, Spain
| | - Enrique Villa
- IACTec Medical Technology Group, Instituto de Astrofísica de Canarias (IAC), La Laguna, Santa Cruz de Tenerife, Spain
| | - Javier González-Fernández
- Departamento de Ingeniería Biomédica. Instituto Tecnológico de Canarias (ITC), Santa Cruz de Tenerife, Santa Cruz de Tenerife, Spain
| | - Yolanda Martín
- IACTec Medical Technology Group, Instituto de Astrofísica de Canarias (IAC), La Laguna, Santa Cruz de Tenerife, Spain
| | - Juan Ruiz-Alzola
- IACTec Medical Technology Group, Instituto de Astrofísica de Canarias (IAC), La Laguna, Santa Cruz de Tenerife, Spain
- Departamento de Señales y Comunicaciones. Instituto Universitario de Investigación Biomédica y Sanitaria (IUIBS). Universidad de Las Palmas de Gran Canaria, Las Palmas de Gran Canaria, Las Palmas, Spain
| |
Collapse
|
46
|
van Zyl FJ, Marais J, Nieuwoudt M, Niesler TR. Computer simulation and physical phantom models for estimating the dielectric properties of rhinoceros tissue. PLoS One 2019; 14:e0216595. [PMID: 31141536 PMCID: PMC6541259 DOI: 10.1371/journal.pone.0216595] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Accepted: 04/24/2019] [Indexed: 11/19/2022] Open
Abstract
In vivo and ex vivo sensors have the potential to aid tracking and anti-poaching endeavours and provide new insights into rhinoceros physiology and environment. However, the propagation of electromagnetic signals in rhinoceros tissue is currently not known. We present simulation and agar models of the rhinoceros that allow the investigation of electromagnetic propagation by in vivo and ex vivo devices without the need for surgery. Since the dielectric properties of rhinoceros tissue have not been documented, the conductivity and permittivity of the skin, fat, muscle, blood and other organs are first approximated by means of a meta-analysis that includes animals with similar physical properties. Subsequently, we develop anatomical models that include dermal layers, internal organs and a skeleton. We also develop a flank model that serves as an approximation of the anatomical model in certain situations. These models are used to determine the viability of communication between an in vivo device and an ex vivo device attached to the hind leg of the animal. Two types of antenna (microstrip-fed planar elliptical monopole antenna and printed inverted-F antenna) and three feasible implant locations (back, neck and chest) are considered. In addition to the computer models, phantom recipes using salt, sugar and agar are developed to match the dielectric properties of each tissue type at the industrial, scientific and medical (ISM) frequencies of 403MHz, 910MHz and 2.4GHz. The average error between the measured and theoretically predicted dielectric values was 6.22% over all recipes and 4.49% for the 2.4 GHz recipe specifically. When considering the predicted efficiency of the transmitting and receiving antennas, an agreement of 67.38% was demonstrated between the computer simulations and laboratory measurements using the agar rhinoceros flank models. Computer simulations using the anatomical model of the rhinoceros indicate that the chest is the optimal implant location and that best signal propagation is achieved using the planar inverted-F antenna (PIFA). Using this configuration, the simulations indicate that communication between the implant and an ex vivo device attached to the hind leg is challenging but possible. Furthermore, we find that the inclusion of factors such as the density and temperature of the phantom materials were found to be critical to the achievement of good agreement between practice and simulation.
Collapse
Affiliation(s)
- Floris J. van Zyl
- Department of Electrical and Electronic Engineering, Stellenbosch University, Stellenbosch, Western Cape, South Africa
| | - Johan Marais
- Faculty of Veterinary Science, University of Pretoria, Pretoria, Gauteng, South Africa
| | - Martin Nieuwoudt
- Institute for Biomedical Engineering (IBE), Stellenbosch University, Stellenbosch, Western Cape, South Africa
| | - Thomas R. Niesler
- Department of Electrical and Electronic Engineering, Stellenbosch University, Stellenbosch, Western Cape, South Africa
| |
Collapse
|
47
|
McIlvain G, Ganji E, Cooper C, Killian ML, Ogunnaike BA, Johnson CL. Reliable preparation of agarose phantoms for use in quantitative magnetic resonance elastography. J Mech Behav Biomed Mater 2019; 97:65-73. [PMID: 31100487 DOI: 10.1016/j.jmbbm.2019.05.001] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 04/28/2019] [Accepted: 05/02/2019] [Indexed: 12/28/2022]
Abstract
Agarose phantoms are one type of phantom commonly used in developing in vivo brain magnetic resonance elastography (MRE) sequences because they are inexpensive and easy to work with, store, and dispose of; however, protocols for creating agarose phantoms are non-standardized and often result in inconsistent phantoms with significant variability in mechanical properties. Many magnetic resonance imaging (MRI) and ultrasound studies use phantoms, but often these phantoms are not tailored for desired mechanical properties and as such are too stiff or not mechanically consistent enough to be used in MRE. In this work, we conducted a systematic study of agarose phantom creation parameters to identify those factors that are most conducive to producing mechanically consistent agarose phantoms for MRE research. We found that cooling rate and liquid temperature affected phantom homogeneity. Phantom stiffness is affected by agar concentration (quadratically), by final liquid temperature and salt content in phantoms, and by the interaction of these two metrics each with stir rate. We captured and quantified the implied relationships with a regression model that can be used to estimate stiffness of resulting phantoms. Additionally, we characterized repeatability, stability over time, impact on MR signal parameters, and differences in agar gel microstructure. This protocol and regression model should prove beneficial in future MRE development studies that use phantoms to determine stiffness measurement accuracy.
Collapse
Affiliation(s)
- Grace McIlvain
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| | - Elahe Ganji
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - Catherine Cooper
- Department of Linguistics and Cognitive Science, University of Delaware, Newark, DE, USA
| | - Megan L Killian
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| | - Babatunde A Ogunnaike
- Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE, USA
| | - Curtis L Johnson
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA.
| |
Collapse
|
48
|
Purvis LAB, Valkovič L, Robson MD, Rodgers CT. Feasibility of absolute quantification for 31 P MRS at 7 T. Magn Reson Med 2019; 82:49-61. [PMID: 30892732 PMCID: PMC6492160 DOI: 10.1002/mrm.27729] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 02/12/2019] [Accepted: 02/14/2019] [Indexed: 12/24/2022]
Abstract
Purpose Phosphorus spectroscopy can differentiate among liver disease stages and types. To quantify absolute concentrations of phosphorus metabolites, sensitivity calibration and transmit field (B1+) correction are required. The trend toward ultrahigh fields (7 T) and the use of multichannel RF coils makes this ever more challenging. We investigated the constraints on reference phantoms, and implemented techniques for the absolute quantification of human liver phosphorus spectra acquired using a 10‐cm loop and a 16‐channel array at 7 T. Methods The effect of phantom conductivity was assessed at 25.8 MHz (1.5 T), 49.9 MHz (3 T), and 120.3 MHz (7 T) by electromagnetic modeling. Radiofrequency field maps (B1±) were measured in phosphate phantoms (18 mM and 40 mM) at 7 T. These maps were used to assess the correction of 4 phantom 3D‐CSI data sets using 3 techniques: phantom replacement, explicit normalization, and simplified normalization. In vivo liver spectra acquired with a 10‐cm loop were corrected with all 3 methods. Simplified normalization was applied to in vivo 16‐channel array data sets. Results Simulations show that quantification errors of less than 3% are achievable using a uniform electrolyte phantom with a conductivity of 0.23‐0.86 S.m−1 at 1.5 T, 0.39‐0.58 S.m−1 at 3 T, and 0.34‐0.42 S.m−1 (16‐19 mM KH2PO4(aq)) at 7 T. The mean γ‐ATP concentration quantified in vivo at 7 T was 1.39 ± 0.30 mmol.L−1 to 1.71 ± 0.35 mmol.L−1 wet tissue for the 10‐cm loop and 1.88 ± 0.25 mmol.L−1 wet tissue for the array. Conclusion It is essential to select a calibration phantom with appropriate conductivity for quantitative phosphorus spectroscopy at 7 T. Using an 18‐mM phosphate phantom and simplified normalization, human liver phosphate metabolite concentrations were successfully quantified at 7 T.
Collapse
Affiliation(s)
- Lucian A B Purvis
- Oxford Centre for Clinical Magnetic Resonance Research, University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom
| | - Ladislav Valkovič
- Oxford Centre for Clinical Magnetic Resonance Research, University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom.,Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Matthew D Robson
- Oxford Centre for Clinical Magnetic Resonance Research, University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom
| | - Christopher T Rodgers
- Oxford Centre for Clinical Magnetic Resonance Research, University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom.,Wolfson Brain Imaging Centre, University of Cambridge, Cambridge, United Kingdom
| |
Collapse
|
49
|
Zhang B, Brown R, Cloos M, Lattanzi R, Sodickson D, Wiggins G. Size-adaptable "Trellis" structure for tailored MRI coil arrays. Magn Reson Med 2018; 81:3406-3415. [PMID: 30575119 DOI: 10.1002/mrm.27637] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Revised: 10/28/2018] [Accepted: 11/22/2018] [Indexed: 11/12/2022]
Abstract
PURPOSE We present a novel, geometrically adjustable, receive coil array whose diameter can be tailored to the subject in order to maximize sensitivity for a range of body sizes. THEORY AND METHODS A key mechanical feature of the size-adaptable receive array is its trellis structure that was motivated by similar structures found in gardening and fencing. Our implementation is a cylindrical trellis that features encircling, diagonally interleaved slats, which are linked together at intersecting points. The ensemble allows expansion or contraction to be controlled with the angle between the slats. This mechanical frame provides a base for radiofrequency coils wherein approximately constant overlap, and therefore coupling between adjacent elements, is maintained when the trellis is expanded or contracted. We demonstrate 2 trellis coil concepts for imaging lower extremity at 3T: a single-row 8-channel array built on a trellis support structure and a multirow 24-channel array in which the coil elements themselves form the trellis structure. RESULTS We show that the adjustable trellis array can accommodate a range of subject sizes with robust signal-to-noise ratio, loading, and coupling. CONCLUSION The trellis coil concept enables an array of surface coils to expand and contract with negligible effect on tuning, matching, and decoupling. This allows an encircling array to conform closely to anatomy of various sizes, which provides significant gains in signal-to-noise ratio.
Collapse
Affiliation(s)
- Bei Zhang
- Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, New York.,Center for Advanced Imaging Innovation and Research, New York University School of Medicine, New York, New York
| | - Ryan Brown
- Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, New York.,Center for Advanced Imaging Innovation and Research, New York University School of Medicine, New York, New York.,Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York
| | - Martijn Cloos
- Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, New York.,Center for Advanced Imaging Innovation and Research, New York University School of Medicine, New York, New York.,Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York.,Tech4Health, NYU Langone Health, New York
| | - Riccardo Lattanzi
- Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, New York.,Center for Advanced Imaging Innovation and Research, New York University School of Medicine, New York, New York.,Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York
| | - Daniel Sodickson
- Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, New York.,Center for Advanced Imaging Innovation and Research, New York University School of Medicine, New York, New York.,Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York.,Tech4Health, NYU Langone Health, New York
| | | |
Collapse
|
50
|
Chen G, Zhang B, Cloos MA, Sodickson DK, Wiggins GC. A highly decoupled transmit-receive array design with triangular elements at 7T. Magn Reson Med 2018; 80:2267-2274. [PMID: 29572959 DOI: 10.1002/mrm.27186] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2017] [Revised: 02/25/2018] [Accepted: 02/28/2018] [Indexed: 11/10/2022]
Abstract
PURPOSE Transmit arrays are essential tools for various RF shimming or parallel excitation techniques at 7T. Here we present an array design with triangular coils to improve diversity in the B1 profiles in the longitudinal (z) direction and allow for next-nearest neighbor decoupling. METHODS Two cylindrical 8-channel arrays having the same length and diameter, 1 of triangular coils and the other of rectangular coils, were constructed and compared in phantom imaging experiments using measures of excitation distribution for a variety of RF shim settings and geometry factor maps for different accelerations on different planes. RESULTS Coupling between elements was -20 dB or better for all triangular coil pairs, but worse than -12 dB for several of the rectangular coil pairs. Both coils could produce adequate shims on a central transverse plane, but the same shim produced worse results off center for the triangular coil array than for the rectangular coil array. Compared to the rectangular coil array, the maximum geometry factor for the triangular coil array was reduced by a factor of 13.1 when using a 2-fold acceleration in the z-direction. CONCLUSION An array design with triangular coils provides effective decoupling mechanisms for nearest and next-nearest neighboring elements, as well as diversity in B1 profiles along the z-direction, although this also means that individual slices must be shimmed separately. This design is well suited for parallel transmit applications while also having high receive sensitivity.
Collapse
Affiliation(s)
- Gang Chen
- Center for Advanced Imaging Innovation and Research (CAI2 R) and Bernard and Irene Schwartz Center for Biomedical Imaging (CBI), Department of Radiology, New York University School of Medicine, New York, New York.,Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York
| | - Bei Zhang
- Center for Advanced Imaging Innovation and Research (CAI2 R) and Bernard and Irene Schwartz Center for Biomedical Imaging (CBI), Department of Radiology, New York University School of Medicine, New York, New York
| | - Martijn A Cloos
- Center for Advanced Imaging Innovation and Research (CAI2 R) and Bernard and Irene Schwartz Center for Biomedical Imaging (CBI), Department of Radiology, New York University School of Medicine, New York, New York.,Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York
| | - Daniel K Sodickson
- Center for Advanced Imaging Innovation and Research (CAI2 R) and Bernard and Irene Schwartz Center for Biomedical Imaging (CBI), Department of Radiology, New York University School of Medicine, New York, New York.,Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York
| | - Graham C Wiggins
- Center for Advanced Imaging Innovation and Research (CAI2 R) and Bernard and Irene Schwartz Center for Biomedical Imaging (CBI), Department of Radiology, New York University School of Medicine, New York, New York
| |
Collapse
|