1
|
Chandran K, Chanda S, Natarajan G, Mehta B. Sanal flow choking in cardiovascular systems: A scientific fallacy. Indian J Thorac Cardiovasc Surg 2024; 40:511-513. [PMID: 38919182 PMCID: PMC11194223 DOI: 10.1007/s12055-023-01666-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 11/23/2023] [Accepted: 11/25/2023] [Indexed: 06/27/2024] Open
Affiliation(s)
- Krishna Chandran
- Department of Mechanical Engineering, Indian Institute of Technology Palakkad, Palakkad, 678623 Kerala India
| | - Samarjeet Chanda
- Department of Mechanical Engineering, Indian Institute of Technology Palakkad, Palakkad, 678623 Kerala India
| | - Ganesh Natarajan
- Department of Mechanical Engineering, Indian Institute of Technology Palakkad, Palakkad, 678623 Kerala India
| | - Balkrishna Mehta
- Department of Mechanical Engineering, Indian Institute of Technology Bhilai, Durg, 491001 Chattisgarh India
| |
Collapse
|
2
|
Tang X, Wu C. A predictive surrogate model for hemodynamics and structural prediction in abdominal aorta for different physiological conditions. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 243:107931. [PMID: 37992570 DOI: 10.1016/j.cmpb.2023.107931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 11/12/2023] [Accepted: 11/14/2023] [Indexed: 11/24/2023]
Abstract
BACKGROUND AND OBJECTIVE This study investigates the application of a Predictive Surrogate Model (PSM) for the prediction of the fluid and solid variables in the abdominal aorta by integrating Proper Orthogonal Decomposition (POD) and Long Short-Term Memory (LSTM) techniques. METHODS The Fluid-Structure Interaction (FSI) solver, which serves as the Full-Order Model (FOM), can capture the blood hemodynamics and structural mechanics precisely for a variety of physiological states, namely the rest and exercise conditions. RESULTS Detailed analyses have been conducted on velocity components, pressure, Wall Shear Stress (WSS), and Oscillatory Shear Index (OSI) variables. Firstly, the reconstruction error has been derived based on a specific number of POD bases to assess the Reduced Order Model (ROM). Notably, the reconstruction error for velocity components in the rest condition is one order of magnitude higher than that in the exercise condition, yet both remained below 10%. This error for pressure is even more minimal, being less than 1%. CONCLUSIONS The PSM is evaluated against rest and exercise conditions, exhibiting promising results despite the inherent complexities of the physiological conditions. Despite the inherent complexities of phenomena in the aorta, the predictive model demonstrates consistent error magnitudes for velocity components and wall-related indices, while solid variables show slightly higher errors.
Collapse
Affiliation(s)
- Xuan Tang
- Department of Physical Education, Yunnan University, Kunming, Yunnan Province, 650000, China; Department of Physical Education, Jeonbuk National University, Jeonju, Jeollabuk, 54896, Korea
| | - ChaoJie Wu
- Department of Physical Education, Jeonbuk National University, Jeonju, Jeollabuk, 54896, Korea.
| |
Collapse
|
3
|
Sun Y, Le H, Lam WA, Alexeev A. Probing interactions of red blood cells and contracting fibrin platelet clots. Biophys J 2023; 122:4123-4134. [PMID: 37598293 PMCID: PMC10645547 DOI: 10.1016/j.bpj.2023.08.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 06/01/2023] [Accepted: 08/10/2023] [Indexed: 08/21/2023] Open
Abstract
Contraction of blood clots plays an important role in blood clotting, a natural process that restores hemostasis and regulates thrombosis in the body. Upon injury, a chain of events culminate in the formation of a soft plug of cells and fibrin fibers attaching to wound edges. Platelets become activated and apply contractile forces to shrink the overall clot size, modify clot structure, and mechanically stabilize the clot. Impaired blood clot contraction results in unhealthy volumetric, mechanical, and structural properties of blood clots associated with a range of severe medical conditions for patients with bleeding and thrombotic disorders. Due to the inherent mechanical complexity of blood clots and a confluence of multiple interdependent factors governing clot contraction, the mechanics and dynamics of clot contraction and the interactions with red blood cells (RBCs) remain elusive. Using an experimentally informed, physics-based mesoscale computational model, we probe the dynamic interactions among platelets, fibrin polymers, and RBCs, and examine the properties of contracted blood clots. Our simulations confirm that RBCs strongly affect clot contraction. We find that RBC retention and compaction in thrombi can be solely a result of mechanistic contraction of fibrin mesh due to platelet activity. Retention of RBCs hinders clot contraction and reduces clot contractility. Expulsion of RBCs located closer to clot outer surface results in the development of a dense fibrin shell in thrombus clots commonly observed in experiments. Our simulations identify the essential parameters and interactions that control blood clot contraction process, highlighting its dependence on platelet concentration and the initial clot size. Furthermore, our computational model can serve as a useful tool in clinically relevant studies of hemostasis and thrombosis disorders, and post thrombotic clot lysis, deformation, and breaking.
Collapse
Affiliation(s)
- Yueyi Sun
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia; Department of Mechanical Engineering, Lafayette College, Easton, Pennsylvania
| | - Hoyean Le
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Wilbur A Lam
- Department of Pediatrics, Division of Pediatric Hematology/Oncology, Aflac Cancer Center and Blood Disorders Service of Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, Georgia; The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia; Winship Cancer Institute of Emory University, Atlanta, Georgia; Parker H. Petit Institute of Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia; Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, Georgia
| | - Alexander Alexeev
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia.
| |
Collapse
|
4
|
Ahmad F, Cheema TA, Rehman K, Ullah M, Jamil M, Park CW. Hemodynamic performance evaluation of neonatal ECMO double lumen cannula using fluid-structure interaction. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3706. [PMID: 37039384 DOI: 10.1002/cnm.3706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 12/30/2022] [Accepted: 03/19/2023] [Indexed: 06/07/2023]
Abstract
Extra corporeal membrane oxygenation (ECMO) is an artificial oxygenation facility, employed in situations of cardio-pulmonary failure. Some diseases i.e., acute respiratory distress syndrome, pulmonary hypertension, corona virus disease (COVID-19) etc. affect oxygenation performance of the lungs thus requiring the need of artificial oxygenation. Critical care teams used ECMO technique during the COVID-19 pandemic to support the heart and lungs of COVID-19 patients who had an acute respiratory or cardiac failure. Double Lumen Cannula (DLC) is one of the most critical components of ECMO as it resides inside the patient and, connects patient with external oxygenation circuit. DLC facilitates delivery and drainage of blood from the patient's body. DLC is characterized by delicate balance of internal and external flows inside a limited space of the right atrium (RA). An optimal performance of the DLC necessitates structural stability under biological and hemodynamic loads, a fact that has been overlooked by previously published studies. In the past, many researchers experimentally and computationally investigated the hemodynamic performance of DLC by employing Eulerian approach, which evaluate instantaneous blood damage without considering blood shear exposure history (qualitative assessment only). The present study is an attempt to address the aforementioned limitations of the previous studies by employing Lagrangian (quantitative assessment) and incorporating the effect of fluid-structure interaction (FSI) to study the hemodynamic performance of neonatal DLC. The study was performed by solving three-dimensional continuity, momentum, and structural mechanics equation(s) by numerical methods for the blood flow through neonatal DLC. A two-way coupled FSI analysis was performed to analyze the effect of DLC structural deformation on its hemodynamic performance. Results show that the return lumen was the most critical section with maximum pressure drop, velocity, shear stresses, and blood damage. Recirculation and residence time of blood in the right atrium (RA) increases with increasing blood flow rates. Considering the structural deformation has led to higher blood damage inside the DLC-atrium system. Maximum Von-Mises stress was present on the side edges of the return lumen that showed direct proportionality with the blood flow rate.
Collapse
Affiliation(s)
- Faiq Ahmad
- Faculty of Mechanical Engineering, GIK Institute of Engineering Sciences and Technology, Topi, 23460, KPK, Pakistan
| | - Taqi Ahmad Cheema
- Faculty of Mechanical Engineering, GIK Institute of Engineering Sciences and Technology, Topi, 23460, KPK, Pakistan
| | - Khawar Rehman
- Department of Civil and Environmental Engineering, Hanyang University, Seoul, 04763, South Korea
- Department of Civil Engineering, GIK Institute of Engineering Sciences and Technology, Topi, 23460, KPK, Pakistan
| | - Minhaj Ullah
- Faculty of Mechanical Engineering, GIK Institute of Engineering Sciences and Technology, Topi, 23460, KPK, Pakistan
| | - Muhammad Jamil
- Analysis Group, Starfish Medical, 455 Boleskine Rd, Victoria, British Columbia, Canada
- Department of Mechanical Engineering, KoÇ University, Sariyar, Istanbul, 34450, Turkey
| | - Cheol Woo Park
- School of Mechanical Engineering, Kyungpook National University, 80 Daehak-Ro, Buk-Gu, Daegu, 41566, South Korea
| |
Collapse
|
5
|
Kharmyssov C, Sekerbayev K, Nurekeyev Z, Gaipov A, Utegulov ZN. Mechano-Chemistry across Phase Transitions in Heated Albumin Protein Solutions. Polymers (Basel) 2023; 15:polym15092039. [PMID: 37177189 PMCID: PMC10180835 DOI: 10.3390/polym15092039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 04/02/2023] [Accepted: 04/14/2023] [Indexed: 05/15/2023] Open
Abstract
The presence of certain proteins in biofluids such as synovial fluid, blood plasma, and saliva gives these fluids non-Newtonian viscoelastic properties. The amount of these protein macromolecules in biofluids is an important biomarker for the diagnosis of various health conditions, including Alzheimer's disease, cardiovascular disorders, and joint quality. However, existing technologies for measuring the behavior of macromolecules in biofluids have limitations, such as long turnaround times, complex protocols, and insufficient sensitivity. To address these issues, we propose non-contact, optical Brillouin and Raman spectroscopy to assess the viscoelasticity and chemistry of non-Newtonian solutions, respectively, at different temperatures in several minutes. In this work, bovine and human serum albumin solution-based biopolymers were studied to obtain both their collective dynamics and molecular chemical evolution across heat-driven phase transitions at various protein concentrations. The observed phase transitions at elevated temperatures could be fully delayed in heated biopolymers by appropriately raising the level of protein concentration. The non-contact optical monitoring of viscoelastic and chemical property evolution could represent novel potential mechano-chemical biomarkers for disease diagnosis and subsequent treatment applications, including hyperthermia.
Collapse
Affiliation(s)
- Chingis Kharmyssov
- Department of Physics, School of Sciences and Humanities, Nazarbayev University, 010000 Astana, Kazakhstan
- Science Department, Astana IT University, 010000 Astana, Kazakhstan
| | - Kairolla Sekerbayev
- Department of Physics, School of Sciences and Humanities, Nazarbayev University, 010000 Astana, Kazakhstan
| | - Zhangatay Nurekeyev
- Department of Physics, School of Sciences and Humanities, Nazarbayev University, 010000 Astana, Kazakhstan
- Institute for Experimental Physics, Hamburg University, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Abduzhappar Gaipov
- Department of Medicine, School of Medicine, Nazarbayev University, 010000 Astana, Kazakhstan
| | - Zhandos N Utegulov
- Department of Physics, School of Sciences and Humanities, Nazarbayev University, 010000 Astana, Kazakhstan
| |
Collapse
|
6
|
Influence of Blood Compressibility on Pulse Wave Propagation Properties Based on Elastic Thin-Walled Tube Theory. PHYSICAL ACTIVITY AND HEALTH 2023. [DOI: 10.5334/paah.214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023] Open
|
7
|
Structure (Epicardial Stenosis) and Function (Microvascular Dysfunction) That Influence Coronary Fractional Flow Reserve Estimation. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12094281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Background. The treatment of coronary stenosis is decided by performing high risk invasive surgery to generate the fractional flow reserve diagnostics index, a ratio of distal to proximal pressures in respect of coronary atherosclerotic plaques. Non-invasive methods are a need of the times that necessitate the use of mathematical models of coronary hemodynamic physiology. This study proposes an extensible mathematical description of the coronary vasculature that provides an estimate of coronary fractional flow reserve. Methods. By adapting an existing computational model of human coronary blood flow, the effects of large vessel stenosis and microvascular disease on fractional flow reserve were quantified. Several simulations generated flow and pressure information, which was used to compute fractional flow reserve under several conditions including focal stenosis, diffuse stenosis, and microvascular disease. Sensitivity analysis was used to uncover the influence of model parameters on fractional flow reserve. The model was simulated as coupled non-linear ordinary differential equations and numerically solved using our implicit higher order method. Results. Large vessel stenosis affected fractional flow reserve. The model predicts that the presence, rather than severity, of microvascular disease affects coronary flow deleteriously. Conclusions. The model provides a computationally inexpensive instrument for future in silico coronary blood flow investigations as well as clinical-imaging decision making. A combination of focal and diffuse stenosis appears to be essential to limit coronary flow. In addition to pressure measurements in the large epicardial vessels, diagnosis of microvascular disease is essential. The independence of the index with respect to heart rate suggests that computationally inexpensive steady state simulations may provide sufficient information to reliably compute the index.
Collapse
|
8
|
Jooss VM, Bolten JS, Huwyler J, Ahmed D. In vivo acoustic manipulation of microparticles in zebrafish embryos. SCIENCE ADVANCES 2022; 8:eabm2785. [PMID: 35333569 PMCID: PMC8956268 DOI: 10.1126/sciadv.abm2785] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
In vivo micromanipulation using ultrasound is an exciting technology with promises for cancer research, brain research, vasculature biology, diseases, and treatment development. In the present work, we demonstrate in vivo manipulation of gas-filled microparticles using zebrafish embryos as a vertebrate model system. Micromanipulation methods often are conducted in vitro, and they do not fully reflect the complex environment associated in vivo. Four piezoelectric actuators were positioned orthogonally to each other around an off-centered fluidic channel that allowed for two-dimensional manipulation of intravenously injected microbubbles. Selective manipulation of microbubbles inside a blood vessel with micrometer precision was achieved without interfering with circulating blood cells. Last, we studied the viability of zebrafish embryos subjected to the acoustic field. This successful high-precision, in vivo acoustic manipulation of intravenously injected microbubbles offers potentially promising therapeutic options.
Collapse
Affiliation(s)
- Viktor Manuel Jooss
- Acoustics Robotics Systems Lab (ARSL), ETH-Zürich, Rüschlikon CH-8803, Switzerland
| | - Jan Stephan Bolten
- Department of Pharmaceutical Sciences, Division of Pharmaceutical Technology, University of Basel, Basel CH-4056, Switzerland
| | - Jörg Huwyler
- Department of Pharmaceutical Sciences, Division of Pharmaceutical Technology, University of Basel, Basel CH-4056, Switzerland
| | - Daniel Ahmed
- Acoustics Robotics Systems Lab (ARSL), ETH-Zürich, Rüschlikon CH-8803, Switzerland
- Corresponding author.
| |
Collapse
|
9
|
Aitekenov S, Sultangaziyev A, Abdirova P, Yussupova L, Gaipov A, Utegulov Z, Bukasov R. Raman, Infrared and Brillouin Spectroscopies of Biofluids for Medical Diagnostics and for Detection of Biomarkers. Crit Rev Anal Chem 2022; 53:1561-1590. [PMID: 35157535 DOI: 10.1080/10408347.2022.2036941] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
This review surveys Infrared, Raman/SERS and Brillouin spectroscopies for medical diagnostics and detection of biomarkers in biofluids, that include urine, blood, saliva and other biofluids. These optical sensing techniques are non-contact, noninvasive and relatively rapid, accurate, label-free and affordable. However, those techniques still have to overcome some challenges to be widely adopted in routine clinical diagnostics. This review summarizes and provides insights on recent advancements in research within the field of vibrational spectroscopy for medical diagnostics and its use in detection of many health conditions such as kidney injury, cancers, cardiovascular and infectious diseases. The six comprehensive tables in the review and four tables in supplementary information summarize a few dozen experimental papers in terms of such analytical parameters as limit of detection, range, diagnostic sensitivity and specificity, and other figures of merits. Critical comparison between SERS and FTIR methods of analysis reveals that on average the reported sensitivity for biomarkers in biofluids for SERS vs FTIR is about 103 to 105 times higher, since LOD SERS are lower than LOD FTIR by about this factor. High sensitivity gives SERS an edge in detection of many biomarkers present in biofluids at low concentration (nM and sub nM), which can be particularly advantageous for example in early diagnostics of cancer or viral infections.HighlightsRaman, Infrared spectroscopies use low volume of biofluidic samples, little sample preparation, fast time of analysis and relatively inexpensive instrumentation.Applications of SERS may be a bit more complicated than applications of FTIR (e.g., limited shelf life for nanoparticles and substrates, etc.), but this can be generously compensated by much higher (by several order of magnitude) sensitivity in comparison to FTIR.High sensitivity makes SERS a noninvasive analytical method of choice for detection, quantification and diagnostics of many health conditions, metabolites, and drugs, particularly in diagnostics of cancer, including diagnostics of its early stages.FTIR, particularly ATR-FTIR can be a method of choice for efficient sensing of many biomarkers, present in urine, blood and other biofluids at sufficiently high concentrations (mM and even a few µM)Brillouin scattering spectroscopy detecting visco-elastic properties of probed liquid medium, may also find application in clinical analysis of some biofluids, such as cerebrospinal fluid and urine.
Collapse
Affiliation(s)
- Sultan Aitekenov
- Department of Chemistry, School of Sciences and Humanities (SSH), Nazarbayev University, Nur-Sultan, Kazakhstan
| | - Alisher Sultangaziyev
- Department of Chemistry, School of Sciences and Humanities (SSH), Nazarbayev University, Nur-Sultan, Kazakhstan
| | - Perizat Abdirova
- Department of Chemistry, School of Sciences and Humanities (SSH), Nazarbayev University, Nur-Sultan, Kazakhstan
| | - Lyailya Yussupova
- Department of Chemistry, School of Sciences and Humanities (SSH), Nazarbayev University, Nur-Sultan, Kazakhstan
| | | | - Zhandos Utegulov
- Department of Physics, School of Sciences and Humanities (SSH), Nazarbayev University, Nur-Sultan, Kazakhstan
| | - Rostislav Bukasov
- Department of Chemistry, School of Sciences and Humanities (SSH), Nazarbayev University, Nur-Sultan, Kazakhstan
| |
Collapse
|
10
|
Guilliams KP, Gupta N, Srinivasan S, Binkley MM, Ying C, Couture L, Gross J, Wallace A, McKinstry RC, Vo K, Lee JM, An H, Goyal MS. MR Imaging Differences in the Circle of Willis between Healthy Children and Adults. AJNR Am J Neuroradiol 2021; 42:2062-2069. [PMID: 34556478 PMCID: PMC8583273 DOI: 10.3174/ajnr.a7290] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Accepted: 07/19/2021] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Asymmetries in the circle of Willis have been associated with several conditions, including migraines and stroke, but they may also be age-dependent. This study examined the impact of age and age-dependent changes in cerebral perfusion on circle of Willis anatomy in healthy children and adults. MATERIALS AND METHODS We performed an observational, cross-sectional study of bright and black-blood imaging of the proximal cerebral vasculature using TOF-MRA and T2 sampling perfection with application-optimized contrasts by using different flip angle evolution (T2-SPACE) imaging at the level of the circle of Willis in 23 healthy children and 43 healthy adults (4-74 years of age). We compared arterial diameters measured manually and cerebral perfusion via pseudocontinuous arterial spin-labeling between children and adults. RESULTS We found that the summed cross-sectional area of the circle of Willis is larger in children than in adults, though the effect size was smaller with T2-SPACE-based measurements than with TOF-MRA. The circle of Willis is also more symmetric in children, and nonvisualized segments occur more frequently in adults than in children. Moreover, the size and symmetry of the circle of Willis correlate with cerebral perfusion. CONCLUSIONS Our results demonstrate that the circle of Willis is different in size and symmetry in healthy children compared with adults, likely associated with developmental changes in cerebral perfusion. Further work is needed to understand why asymmetric vasculature develops in some but not all adults.
Collapse
Affiliation(s)
- K P Guilliams
- From the Department of Neurology (K.P.G., M.M.B., J.-M.L., M.S.G.)
- Department of Pediatrics (K.P.G., R.C.M.)
- Mallinckrodt Institute of Radiology (K.P.G., N.G., S.S., C.Y., L.C., R.C.M., K.V., J.-M.L., H.A., M.S.G.)
| | - N Gupta
- Mallinckrodt Institute of Radiology (K.P.G., N.G., S.S., C.Y., L.C., R.C.M., K.V., J.-M.L., H.A., M.S.G.)
| | - S Srinivasan
- Mallinckrodt Institute of Radiology (K.P.G., N.G., S.S., C.Y., L.C., R.C.M., K.V., J.-M.L., H.A., M.S.G.)
| | - M M Binkley
- From the Department of Neurology (K.P.G., M.M.B., J.-M.L., M.S.G.)
| | - C Ying
- Mallinckrodt Institute of Radiology (K.P.G., N.G., S.S., C.Y., L.C., R.C.M., K.V., J.-M.L., H.A., M.S.G.)
| | - L Couture
- Mallinckrodt Institute of Radiology (K.P.G., N.G., S.S., C.Y., L.C., R.C.M., K.V., J.-M.L., H.A., M.S.G.)
| | - J Gross
- Division of Neuroradiology (J.G.), Midwest Radiology, St. Paul, Minnesota
| | - A Wallace
- Department of Neurointerventional Surgery (A.W.), Ascension Columbia St. Mary's Hospital, Milwaukee, Wisconsin
| | - R C McKinstry
- Department of Pediatrics (K.P.G., R.C.M.)
- Mallinckrodt Institute of Radiology (K.P.G., N.G., S.S., C.Y., L.C., R.C.M., K.V., J.-M.L., H.A., M.S.G.)
| | - K Vo
- Mallinckrodt Institute of Radiology (K.P.G., N.G., S.S., C.Y., L.C., R.C.M., K.V., J.-M.L., H.A., M.S.G.)
| | - J-M Lee
- From the Department of Neurology (K.P.G., M.M.B., J.-M.L., M.S.G.)
- Mallinckrodt Institute of Radiology (K.P.G., N.G., S.S., C.Y., L.C., R.C.M., K.V., J.-M.L., H.A., M.S.G.)
- Department of Biomedical Engineering (J.-M.L.)
| | - H An
- Mallinckrodt Institute of Radiology (K.P.G., N.G., S.S., C.Y., L.C., R.C.M., K.V., J.-M.L., H.A., M.S.G.)
| | - M S Goyal
- From the Department of Neurology (K.P.G., M.M.B., J.-M.L., M.S.G.)
- Mallinckrodt Institute of Radiology (K.P.G., N.G., S.S., C.Y., L.C., R.C.M., K.V., J.-M.L., H.A., M.S.G.)
- Neuroscience (M.S.G.), Washington University School of Medicine, St. Louis, Missouri
| |
Collapse
|
11
|
Progressive Calcification in Bicuspid Valves: A Coupled Hemodynamics and Multiscale Structural Computations. Ann Biomed Eng 2021; 49:3310-3322. [PMID: 34708308 DOI: 10.1007/s10439-021-02877-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Accepted: 10/13/2021] [Indexed: 10/20/2022]
Abstract
Bicuspid aortic valve (BAV) is the most common congenital heart disease. Calcific aortic valve disease (CAVD) accounts for the majority of aortic stenosis (AS) cases. Half of the patients diagnosed with AS have a BAV, which has an accelerated progression rate. This study aims to develop a computational modeling approach of both the calcification progression in BAV, and its biomechanical response incorporating fluid-structure interaction (FSI) simulations during the disease progression. The calcification is patient-specifically reconstructed from Micro-CT images of excised calcified BAV leaflets, and processed with a novel reverse calcification technique that predicts prior states of CAVD using a density-based criterion, resulting in a multilayered calcified structure. Four progressive multilayered calcified BAV models were generated: healthy, mild, moderate, and severe, and were modeled by FSI simulations during the full cardiac cycle. A valve apparatus model, composed of the excised calcified BAV leaflets, was tested in an in-vitro pulse duplicator, to validate the severe model. The healthy model was validated against echocardiography scans. Progressive AS was characterized by higher systolic jet flow velocities (2.08, 2.3, 3.37, and 3.85 m s-1), which induced intense vortices surrounding the jet, coupled with irregular recirculation backflow patterns that elevated viscous shear stresses on the leaflets. This study shed light on the fluid-structure mechanism that drives CAVD progression in BAV patients.
Collapse
|
12
|
Rubio JE, Skotak M, Alay E, Sundaramurthy A, Subramaniam DR, Kote VB, Yeoh S, Monson K, Chandra N, Unnikrishnan G, Reifman J. Does Blast Exposure to the Torso Cause a Blood Surge to the Brain? Front Bioeng Biotechnol 2020; 8:573647. [PMID: 33392161 PMCID: PMC7773947 DOI: 10.3389/fbioe.2020.573647] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Accepted: 11/16/2020] [Indexed: 02/04/2023] Open
Abstract
The interaction of explosion-induced blast waves with the torso is suspected to contribute to brain injury. In this indirect mechanism, the wave-torso interaction is assumed to generate a blood surge, which ultimately reaches and damages the brain. However, this hypothesis has not been comprehensively and systematically investigated, and the potential role, if any, of the indirect mechanism in causing brain injury remains unclear. In this interdisciplinary study, we performed experiments and developed mathematical models to address this knowledge gap. First, we conducted blast-wave exposures of Sprague-Dawley rats in a shock tube at incident overpressures of 70 and 130 kPa, where we measured carotid-artery and brain pressures while limiting exposure to the torso. Then, we developed three-dimensional (3-D) fluid-structure interaction (FSI) models of the neck and cerebral vasculature and, using the measured carotid-artery pressures, performed simulations to predict mass flow rates and wall shear stresses in the cerebral vasculature. Finally, we developed a 3-D finite element (FE) model of the brain and used the FSI-computed vasculature pressures to drive the FE model to quantify the blast-exposure effects in the brain tissue. The measurements from the torso-only exposure experiments revealed marginal increases in the peak carotid-artery overpressures (from 13.1 to 28.9 kPa). Yet, relative to the blast-free, normotensive condition, the FSI simulations for the blast exposures predicted increases in the peak mass flow rate of up to 255% at the base of the brain and increases in the wall shear stress of up to 289% on the cerebral vasculature. In contrast, our simulations suggest that the effect of the indirect mechanism on the brain-tissue-strain response is negligible (<1%). In summary, our analyses show that the indirect mechanism causes a sudden and abundant stream of blood to rapidly propagate from the torso through the neck to the cerebral vasculature. This blood surge causes a considerable increase in the wall shear stresses in the brain vasculature network, which may lead to functional and structural effects on the cerebral veins and arteries, ultimately leading to vascular pathology. In contrast, our findings do not support the notion of strain-induced brain-tissue damage due to the indirect mechanism.
Collapse
Affiliation(s)
- Jose E Rubio
- Department of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, United States Army Medical Research and Development Command, Fort Detrick, MD, United States.,The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, MD, United States
| | - Maciej Skotak
- Department of Biomedical Engineering, Center for Injury Biomechanics, Materials, and Medicine, New Jersey Institute of Technology, Newark, NJ, United States.,Blast Induced Neurotrauma Division, Walter Reed Army Institute of Research, Silver Spring, MD, United States
| | - Eren Alay
- Department of Biomedical Engineering, Center for Injury Biomechanics, Materials, and Medicine, New Jersey Institute of Technology, Newark, NJ, United States
| | - Aravind Sundaramurthy
- Department of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, United States Army Medical Research and Development Command, Fort Detrick, MD, United States.,The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, MD, United States
| | - Dhananjay Radhakrishnan Subramaniam
- Department of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, United States Army Medical Research and Development Command, Fort Detrick, MD, United States.,The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, MD, United States
| | - Vivek Bhaskar Kote
- Department of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, United States Army Medical Research and Development Command, Fort Detrick, MD, United States.,The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, MD, United States
| | - Stewart Yeoh
- Department of Biomedical Engineering, College of Engineering, The University of Utah, Salt Lake City, UT, United States
| | - Kenneth Monson
- Department of Biomedical Engineering, College of Engineering, The University of Utah, Salt Lake City, UT, United States.,Department of Mechanical Engineering, College of Engineering, The University of Utah, Salt Lake City, UT, United States
| | - Namas Chandra
- Department of Biomedical Engineering, Center for Injury Biomechanics, Materials, and Medicine, New Jersey Institute of Technology, Newark, NJ, United States
| | - Ginu Unnikrishnan
- Department of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, United States Army Medical Research and Development Command, Fort Detrick, MD, United States.,The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, MD, United States
| | - Jaques Reifman
- Department of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, United States Army Medical Research and Development Command, Fort Detrick, MD, United States
| |
Collapse
|
13
|
Gaipov A, Utegulov Z, Bukasov R, Turebekov D, Tarlykov P, Markhametova Z, Nurekeyev Z, Kunushpayeva Z, Sultangaziyev A. Development and validation of hybrid Brillouin-Raman spectroscopy for non-contact assessment of mechano-chemical properties of urine proteins as biomarkers of kidney diseases. BMC Nephrol 2020; 21:229. [PMID: 32539773 PMCID: PMC7296939 DOI: 10.1186/s12882-020-01890-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 06/11/2020] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Proteinuria is a major marker of chronic kidney disease (CKD) progression and the predictor of cardiovascular mortality. The rapid development of renal failure is expected in those patients who have higher level of proteinuria however, some patients may have slow decline of renal function despite lower level of urinary protein excretion. The different mechanical (visco-elastic) and chemical properties, as well as the proteome profiles of urinary proteins might explain their tubular toxicity mechanism. Brillouin light scattering (BLS) and surface enhanced Raman scattering (SERS) spectroscopies are non-contact, laser optical-based techniques providing visco-elastic and chemical property information of probed human biofluids. We proposed to study and compare these properties of urinary proteins using BLS and SERS spectroscopies in nephrotic patient and validate hybrid BLS-SERS spectroscopy in diagnostic of urinary proteins as well as their profiling. The project ultimately aims for the development of an optical spectroscopic sensor for rapid, non-contact monitoring of urine samples from patients in clinical settings. METHODS BLS and SERS spectroscopies will be used for non-contact assessment of urinary proteins in proteinuric patients and healthy subjects and will be cross-validated by Liquid Chromatography-Mass Spectrometry (LC-MS). Participants will be followed-up during the 1 year and all adverse events such as exacerbation of proteinuria, progression of CKD, complications of nephrotic syndrome, disease relapse rate and inefficacy of treatment regimen will be registered referencing incident dates. Associations between urinary protein profiles (obtained from BLS and SERS as well as LC-MS) and adverse outcomes will be evaluated to identify most unfavored protein profiles. DISCUSSION This prospective study is focused on the development of non-contact hybrid BLS - SERS sensing tool and its clinical deployment for diagnosis and prognosis of proteinuria. We will identify the most important types of urine proteins based on their visco-elasticity, amino-acid profile and molecular weight responsible for the most severe cases of proteinuria and progressive renal function decline. We will aim for the developed hybrid BLS - SERS sensor, as a new diagnostic & prognostic tool, to be transferred to other biomedical applications. TRIAL REGISTRATION The trial has been approved by ClinicalTrials.gov (Trial registration ID NCT04311684). The date of registration was March 17, 2020.
Collapse
Affiliation(s)
- Abduzhappar Gaipov
- Department of Clinical Sciences, Nazarbayev University School of Medicine, Nur-Sultan, Kazakhstan, 010000.
| | - Zhandos Utegulov
- Department of Physics, School of Sciences and Humanities, Nazarbayev University, Nur-Sultan, Kazakhstan, 010000
| | - Rostislav Bukasov
- Department of Chemistry, School of Sciences and Humanities, Nazarbayev University, Nur-Sultan, Kazakhstan, 010000
| | - Duman Turebekov
- Department of Internal Medicine, Astana Medical University, Nur-Sultan, Kazakhstan, 010000
| | - Pavel Tarlykov
- Department of Proteomics and Mass Spectrometry, National Center for Biotechnology, Nur-Sultan, Kazakhstan, 010000
| | - Zhannur Markhametova
- Department of Clinical Sciences, Nazarbayev University School of Medicine, Nur-Sultan, Kazakhstan, 010000
| | - Zhangatay Nurekeyev
- Department of Physics, School of Sciences and Humanities, Nazarbayev University, Nur-Sultan, Kazakhstan, 010000
| | - Zhanar Kunushpayeva
- Department of Chemistry, School of Sciences and Humanities, Nazarbayev University, Nur-Sultan, Kazakhstan, 010000
| | - Alisher Sultangaziyev
- Department of Chemistry, School of Sciences and Humanities, Nazarbayev University, Nur-Sultan, Kazakhstan, 010000
| |
Collapse
|
14
|
de Oliveira DMC, Abdullah N, Green NC, Espino DM. Biomechanical Assessment of Bicuspid Aortic Valve Phenotypes: A Fluid-Structure Interaction Modelling Approach. Cardiovasc Eng Technol 2020; 11:431-447. [PMID: 32519086 DOI: 10.1007/s13239-020-00469-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 06/04/2020] [Indexed: 12/11/2022]
Abstract
PURPOSE Bicuspid aortic valve (BAV) is a congenital heart malformation with phenotypic heterogeneity. There is no prior computational study that assesses the haemodynamic and valve mechanics associated with BAV type 2 against a healthy tricuspid aortic valve (TAV) and other BAV categories. METHODS A proof-of-concept study incorporating three-dimensional fluid-structure interaction (FSI) models with idealised geometries (one TAV and six BAVs, namely type 0 with lateral and anterior-posterior orientations, type 1 with R-L, N-R and N-L leaflet fusion and type 2) has been developed. Transient physiological boundary conditions have been applied and simulations were run using an Arbitrary Lagrangian-Eulerian formulation. RESULTS Our results showed the presence of abnormal haemodynamics in the aorta and abnormal valve mechanics: type 0 BAVs yielded the best haemodynamical and mechanical outcomes, but cusp stress distribution varied with valve orifice orientation, which can be linked to different cusp calcification location onset; type 1 BAVs gave rise to similar haemodynamics and valve mechanics, regardless of raphe position, but this position altered the location of abnormal haemodynamic features; finally, type 2 BAV constricted the majority of blood flow, exhibiting the most damaging haemodynamic and mechanical repercussions when compared to other BAV phenotypes. CONCLUSION The findings of this proof-of-concept work suggest that there are specific differences across haemodynamics and valve mechanics associated with BAV phenotypes, which may be critical to subsequent processes associated with their pathophysiology processes.
Collapse
Affiliation(s)
- Diana M C de Oliveira
- Department of Mechanical Engineering, University of Birmingham, Birmingham, B15 2TT, UK.
| | - Nazirul Abdullah
- Department of Mechanical Engineering, University of Birmingham, Birmingham, B15 2TT, UK
| | - Naomi C Green
- Department of Mechanical Engineering, University of Birmingham, Birmingham, B15 2TT, UK
| | - Daniel M Espino
- Department of Mechanical Engineering, University of Birmingham, Birmingham, B15 2TT, UK
| |
Collapse
|
15
|
Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage. Med Biol Eng Comput 2019; 57:2129-2143. [PMID: 31372826 DOI: 10.1007/s11517-019-02012-y] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Accepted: 07/08/2019] [Indexed: 12/17/2022]
Abstract
Calcific aortic valve disease (CAVD) is characterized by stiffened aortic valve leaflets. Bicuspid aortic valve (BAV) is the most common congenital heart disease. Transcatheter aortic valve replacement (TAVR) is a treatment approach for CAVD where a stent with mounted bioprosthetic valve is deployed on the stenotic valve. Performing TAVR in calcified BAV patients may be associated with post-procedural complications due to the BAV asymmetrical structure. This study aims to develop refined computational models simulating the deployments of Evolut R and PRO TAVR devices in a representative calcified BAV. The paravalvular leakage (PVL) was also calculated by computational fluid dynamics simulations. Computed tomography scan of severely stenotic BAV patient was acquired. The 3D calcium deposits were generated and embedded inside a parametric model of the BAV. Deployments of the Evolut R and PRO inside the calcified BAV were simulated in five bioprosthesis leaflet orientations. The hypothesis of asymmetric and elliptic stent deployment was confirmed. Positioning the bioprosthesis commissures aligned with the native commissures yielded the lowest PVL (15.7 vs. 29.5 mL/beat). The Evolut PRO reduced the PVL in half compared with the Evolut R (15.7 vs. 28.7 mL/beat). The proposed biomechanical computational model could optimize future TAVR treatment in BAV patients. Graphical abstract.
Collapse
|
16
|
Lavon K, Halevi R, Marom G, Ben Zekry S, Hamdan A, Joachim Schäfers H, Raanani E, Haj-Ali R. Fluid-Structure Interaction Models of Bicuspid Aortic Valves: The Effects of Nonfused Cusp Angles. J Biomech Eng 2019; 140:2661744. [PMID: 29098290 DOI: 10.1115/1.4038329] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Indexed: 12/21/2022]
Abstract
Bicuspid aortic valve (BAV) is the most common type of congenital heart disease, occurring in 0.5-2% of the population, where the valve has only two rather than the three normal cusps. Valvular pathologies, such as aortic regurgitation and aortic stenosis, are associated with BAVs, thereby increasing the need for a better understanding of BAV kinematics and geometrical characteristics. The aim of this study is to investigate the influence of the nonfused cusp (NFC) angle in BAV type-1 configuration on the valve's structural and hemodynamic performance. Toward that goal, a parametric fluid-structure interaction (FSI) modeling approach of BAVs is presented. Four FSI models were generated with varying NFC angles between 120 deg and 180 deg. The FSI simulations were based on fully coupled structural and fluid dynamic solvers and corresponded to physiologic values, including the anisotropic hyper-elastic behavior of the tissue. The simulated angles led to different mechanical behavior, such as eccentric jet flow direction with a wider opening shape that was found for the smaller NFC angles, while a narrower opening orifice followed by increased jet flow velocity was observed for the larger NFC angles. Smaller NFC angles led to higher concentrated flow shear stress (FSS) on the NFC during peak systole, while higher maximal principal stresses were found in the raphe region during diastole. The proposed biomechanical models could explain the early failure of BAVs with decreased NFC angles, and suggests that a larger NFC angle is preferable in suture annuloplasty BAV repair surgery.
Collapse
Affiliation(s)
- Karin Lavon
- Faculty of Engineering, School of Mechanical Engineering, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Rotem Halevi
- Faculty of Engineering, School of Mechanical Engineering, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Gil Marom
- Biomedical Engineering Department, Stony Brook University, Stony Brook, NY 11794
| | - Sagit Ben Zekry
- Echocardiography Laboratory, Chaim Sheba Medical Center, Tel Hashomer 52621, Israel
| | - Ashraf Hamdan
- Department of Cardiology, Rabin Medical Center, Petach Tikva 4941492, Israel
| | - Hans Joachim Schäfers
- Department of Thoracic and Cardiovascular Surgery, University Hospitals of Saarland, Homburg 66421, Germany
| | - Ehud Raanani
- Department of Cardio-thoracic Surgery, Chaim Sheba Medical Center, Tel Hashomer 52621, Israel
| | - Rami Haj-Ali
- School of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv 6997801, Israel
| |
Collapse
|
17
|
Permeability and fluid flow-induced wall shear stress of bone tissue scaffolds: Computational fluid dynamic analysis using Newtonian and non-Newtonian blood flow models. Comput Biol Med 2018; 99:201-208. [DOI: 10.1016/j.compbiomed.2018.06.017] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 06/02/2018] [Accepted: 06/18/2018] [Indexed: 12/17/2022]
|
18
|
Fernandes J, Vendramini E, Miranda AM, Silva C, Dinis H, Coizet V, David O, Mendes PM. Design and Performance Assessment of a Solid-State Microcooler for Thermal Neuromodulation. MICROMACHINES 2018; 9:mi9020047. [PMID: 30393323 PMCID: PMC6187761 DOI: 10.3390/mi9020047] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Revised: 01/25/2018] [Accepted: 01/26/2018] [Indexed: 01/06/2023]
Abstract
It is well known that neural activity can be modulated using a cooling device. The applications of this technique range from the treatment of medication-resistant cerebral diseases to brain functional mapping. Despite the potential benefits of such technique, its use has been limited due to the lack of suitable thermal modulators. This paper presents the design and validation of a solid-state cooler that was able to modulate the neural activity of rodents without the use of large and unpractical water pipes. A miniaturized thermal control solution based exclusively on solid-state devices was designed, occupying only 5 mm × 5 mm × 3 mm, and featuring the potential for wireless power and communications. The cold side of the device was cooled to 26 °C, while the hot side was kept below 43 °C. This range of temperatures is compatible with brain cooling and efficient enough for achieving some control of neural activity.
Collapse
Affiliation(s)
- José Fernandes
- CMEMS, University of Minho, 4800-058 Guimarães, Portugal.
| | - Estelle Vendramini
- Grenoble Institut des Neurosciences, U1216 Inserm, Université Grenoble Alpes, 38400 Grenoble, France.
| | - Ana M Miranda
- CMEMS, University of Minho, 4800-058 Guimarães, Portugal.
| | | | - Hugo Dinis
- CMEMS, University of Minho, 4800-058 Guimarães, Portugal.
| | - Veronique Coizet
- Grenoble Institut des Neurosciences, U1216 Inserm, Université Grenoble Alpes, 38400 Grenoble, France.
| | - Olivier David
- Grenoble Institut des Neurosciences, U1216 Inserm, Université Grenoble Alpes, 38400 Grenoble, France.
| | | |
Collapse
|
19
|
Singh J, Brunner G, Morrisett JD, Ballantyne CM, Lumsden AB, Shah DJ, Decuzzi P. Patient-Specific Flow Descriptors and Normalized wall index in Peripheral Artery Disease: a Preliminary Study. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING. IMAGING & VISUALIZATION 2016; 6:119-127. [PMID: 29503774 PMCID: PMC5830147 DOI: 10.1080/21681163.2016.1184589] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2015] [Accepted: 04/26/2016] [Indexed: 12/13/2022]
Abstract
BACKGROUND AND AIMS MRI-based hemodynamics have been applied to study the relationship between time-averaged wall shear stresses (TAWSS), oscillatory shear index (OSI) and atherosclerotic lesions in the coronary arteries, carotid artery, and human aorta. However, the role of TAWSS and OSI are poorly understood in lower extremity arteries. The aim of this work was to investigate the feasibility of hemodynamic assessment of the superficial femoral artery (SFA) in patients with peripheral artery disease (PAD) and we hypothesized that there is an association between TAWSS and OSI, respectively, and atherosclerotic burden expressed as the normalized wall index (NWI). METHODS Six cases of 3D vascular geometries of the SFA and related inlet/outlet flow conditions were extracted from patient-specific MRI data including baseline, 12 and 24 months. Blood flow simulations were performed to compute flow descriptors, including TAWSS and OSI, and NWI. RESULTS NWI was correlated positively with TAWSS (correlation coefficient: r = 0.592; p < 0.05). NWI was correlated negatively with OSI (correlation coefficient: r = -0.310, p < 0.01). Spatially averaged TAWSS and average NWI increased significantly between baseline and 24-months, whereas OSI decreased over 2-years. CONCLUSIONS In this pilot study with a limited sample size, TAWSS was positively associated with NWI, a measure of plaque burden, whereas OSI showed an inverse relationship. However, our findings need to be verified in a larger prospective study. MRI-based study of hemodynamics is feasible in the superficial femoral artery.
Collapse
Affiliation(s)
- Jaykrishna Singh
- Department of Translational Imaging, The Houston Methodist Research Institute (HMRI), Houston, TX
| | - Gerd Brunner
- Division of Atherosclerosis and Vascular Medicine, Department of Medicine, Baylor College of Medicine, Houston, TX
- Methodist DeBakey Heart & Vascular Center, The Houston Methodist Research Institute (HMRI), Houston, TX
| | - Joel D. Morrisett
- Division of Atherosclerosis and Vascular Medicine, Department of Medicine, Baylor College of Medicine, Houston, TX
- Methodist DeBakey Heart & Vascular Center, The Houston Methodist Research Institute (HMRI), Houston, TX
| | - Christie M. Ballantyne
- Division of Atherosclerosis and Vascular Medicine, Department of Medicine, Baylor College of Medicine, Houston, TX
- Methodist DeBakey Heart & Vascular Center, The Houston Methodist Research Institute (HMRI), Houston, TX
| | - Alan B. Lumsden
- Methodist DeBakey Heart & Vascular Center, The Houston Methodist Research Institute (HMRI), Houston, TX
| | - Dipan J. Shah
- Methodist DeBakey Heart & Vascular Center, The Houston Methodist Research Institute (HMRI), Houston, TX
| | - Paolo Decuzzi
- Department of Translational Imaging, The Houston Methodist Research Institute (HMRI), Houston, TX
| |
Collapse
|
20
|
Estrogen Preserves Pulsatile Pulmonary Arterial Hemodynamics in Pulmonary Arterial Hypertension. Ann Biomed Eng 2016; 45:632-643. [PMID: 27557900 DOI: 10.1007/s10439-016-1716-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2016] [Accepted: 08/18/2016] [Indexed: 10/21/2022]
Abstract
Pulmonary arterial hypertension (PAH) is caused by extensive pulmonary vascular remodeling that increases right ventricular (RV) afterload and leads to RV failure. PAH predominantly affects women; paradoxically, female PAH patients have better outcomes than men. The roles of estrogen in PAH remain controversial, which is referred to as "the estrogen paradox". Here, we sought to determine the role of estrogen in pulsatile pulmonary arterial hemodynamic changes and its impact on RV functional adaption to PAH. Female mice were ovariectomized and replenished with estrogen or placebo. PAH was induced with SU5416 and chronic hypoxia. In vivo hemodynamic measurements showed that (1) estrogen prevented loss of pulmonary vascular compliance with limited effects on the increase of pulmonary vascular resistance in PAH; (2) estrogen attenuated increases in wave reflections in PAH and limited its adverse effects on PA systolic and pulse pressures; and (3) estrogen maintained the total hydraulic power and preserved transpulmonary vascular efficiency in PAH. This study demonstrates that estrogen preserves pulmonary vascular compliance independent of pulmonary vascular resistance, which provides a mechanical mechanism for ability of estrogen to delay disease progression without preventing onset. The estrogenic protection of pulsatile pulmonary hemodynamics underscores the therapeutic potential of estrogen in PAH.
Collapse
|
21
|
Meng Z, Bustamante Lopez SC, Meissner KE, Yakovlev VV. Subcellular measurements of mechanical and chemical properties using dual Raman-Brillouin microspectroscopy. JOURNAL OF BIOPHOTONICS 2016; 9:201-7. [PMID: 26929086 DOI: 10.1002/jbio.201500163] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2015] [Revised: 09/01/2015] [Accepted: 09/16/2015] [Indexed: 05/27/2023]
Abstract
Brillouin microspectroscopy is a powerful technique for noninvasive optical imaging. In particular, Brillouin microspectroscopy uniquely allows assessing a sample's mechanical properties with microscopic spatial resolution. Recent advances in background-free Brillouin microspectroscopy make it possible to image scattering samples without substantial degradation of the data quality. However, measurements at the cellular- and subcellular-level have never been performed to date due to the limited signal strength. In this report, by adopting our recently optimized VIPA-based Brillouin spectrometer, we probed the microscopic viscoelasticity of individual red blood cells. These measurements were supplemented by chemically specific measurements using Raman microspectroscopy.
Collapse
Affiliation(s)
- Zhaokai Meng
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843-3120, USA.
| | | | - Kenith E Meissner
- College of Engineering, Swansea University, Singleton Park, Swansea, SA2 8PP, Wales, United Kingdom
| | - Vladislav V Yakovlev
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843-3120, USA
| |
Collapse
|
22
|
Fluid-structure interaction modeling of calcific aortic valve disease using patient-specific three-dimensional calcification scans. Med Biol Eng Comput 2016; 54:1683-1694. [PMID: 26906280 DOI: 10.1007/s11517-016-1458-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2015] [Accepted: 01/29/2016] [Indexed: 01/08/2023]
Abstract
Calcific aortic valve disease (CAVD) is characterized by calcification accumulation and thickening of the aortic valve cusps, leading to stenosis. The importance of fluid flow shear stress in the initiation and regulation of CAVD progression is well known and has been studied recently using fluid-structure interaction (FSI) models. While cusp calcifications are three-dimensional (3D) masses, previously published FSI models have represented them as either stiffened or thickened two-dimensional (2D) cusps. This study investigates the hemodynamic effect of these calcifications employing FSI models using 3D patient-specific calcification masses. A new reverse calcification technique (RCT) is used for modeling different stages of calcification growth based on the spatial distribution of calcification density. The RCT is applied to generate the 3D calcification deposits reconstructed from a patient-specific CT scans. Our results showed that consideration of 3D calcification deposits led to both higher fluid shear stresses and unique fluid shear stress distribution on the aortic side of the cusps that may have an impact on the calcification growth rate. However, the flow did not seem to affect the geometry of the calcification during the growth phase.
Collapse
|
23
|
Blood Density Is Nearly Equal to Water Density: A Validation Study of the Gravimetric Method of Measuring Intraoperative Blood Loss. J Vet Med 2015; 2015:152730. [PMID: 26464949 PMCID: PMC4590883 DOI: 10.1155/2015/152730] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Accepted: 12/01/2014] [Indexed: 12/01/2022] Open
Abstract
Purpose. The gravimetric method of weighing surgical sponges is used to quantify intraoperative blood loss. The dry mass minus the wet mass of the gauze equals the volume of blood lost. This method assumes that the density of blood is equivalent to water (1 gm/mL). This study's purpose was to validate the assumption that the density of blood is equivalent to water and to correlate density with hematocrit. Methods. 50 µL of whole blood was weighed from eighteen rats. A distilled water control was weighed for each blood sample. The averages of the blood and water were compared utilizing a Student's unpaired, one-tailed t-test. The masses of the blood samples and the hematocrits were compared using a linear regression. Results. The average mass of the eighteen blood samples was 0.0489 g and that of the distilled water controls was 0.0492 g. The t-test showed P = 0.2269 and R2 = 0.03154. The hematocrit values ranged from 24% to 48%. The linear regression R2 value was 0.1767. Conclusions. The R2 value comparing the blood and distilled water masses suggests high correlation between the two populations. Linear regression showed the hematocrit was not proportional to the mass of the blood. The study confirmed that the measured density of blood is similar to water.
Collapse
|
24
|
Schreier DA, Hacker TA, Hunter K, Eickoff J, Liu A, Song G, Chesler N. Impact of increased hematocrit on right ventricular afterload in response to chronic hypoxia. J Appl Physiol (1985) 2014; 117:833-9. [PMID: 25170068 DOI: 10.1152/japplphysiol.00059.2014] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Chronic hypoxia causes chronic mountain sickness through hypoxia-induced pulmonary hypertension (HPH) and increased hematocrit. Here, we investigated the impact of increased hematocrit and HPH on right ventricular (RV) afterload via pulmonary vascular impedance. Mice were exposed to chronic normobaric hypoxia (10% oxygen) for 10 (10H) or 21 days (21H). After baseline hemodynamic measurements, ∼500 μl of blood were extracted and replaced with an equal volume of hydroxyethylstarch to normalize hematocrit and all hemodynamic measurements were repeated. In addition, ∼500 μl of blood were extracted and replaced in control mice with an equal volume of 90% hematocrit blood. Chronic hypoxia increased input resistance (Z0 increased 82% in 10H and 138% in 21H vs. CTL; P < 0.05) and characteristic impedance (ZC increased 76% in 10H and 109% in 21H vs. CTL; P < 0.05). Hematocrit normalization did not decrease mean pulmonary artery pressure but did increase cardiac output such that both Z0 and ZC decreased toward control levels. Increased hematocrit in control mice did not increase pressure but did decrease cardiac output such that Z0 increased. The paradoxical decrease in ZC with an acute drop in hematocrit and no change in pressure are likely due to inertial effects secondary to the increase in cardiac output. A novel finding of this study is that an increase in hematocrit affects the pulsatile RV afterload in addition to the steady RV afterload (Z0). Furthermore, our results highlight that the conventional interpretation of ZC as a measure of proximal artery stiffness is not valid in all physiological and pathological states.
Collapse
Affiliation(s)
- David A Schreier
- Department of Biomedical Engineering University of Wisconsin, Madison, Wisconson
| | - Timothy A Hacker
- Department of Medicine Medical Science Center, Madison, Wisconsin; and
| | - Kendall Hunter
- Department of Bioengineering University of Colorado, Aurora, Colorado
| | - Jens Eickoff
- Department of Medicine Medical Science Center, Madison, Wisconsin; and
| | - Aiping Liu
- Department of Biomedical Engineering University of Wisconsin, Madison, Wisconson
| | - Gouqing Song
- Department of Medicine Medical Science Center, Madison, Wisconsin; and
| | - Naomi Chesler
- Department of Biomedical Engineering University of Wisconsin, Madison, Wisconson; Department of Medicine Medical Science Center, Madison, Wisconsin; and
| |
Collapse
|
25
|
Marom G, Peleg M, Halevi R, Rosenfeld M, Raanani E, Hamdan A, Haj-Ali R. Fluid-structure interaction model of aortic valve with porcine-specific collagen fiber alignment in the cusps. J Biomech Eng 2014; 135:101001-6. [PMID: 23775457 DOI: 10.1115/1.4024824] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2012] [Accepted: 06/05/2013] [Indexed: 11/08/2022]
Abstract
Native aortic valve cusps are composed of collagen fibers embedded in their layers. Each valve cusp has its own distinctive fiber alignment with varying orientations and sizes of its fiber bundles. However, prior mechanical behavior models have not been able to account for the valve-specific collagen fiber networks (CFN) or for their differences between the cusps. This study investigates the influence of this asymmetry on the hemodynamics by employing two fully coupled fluid-structure interaction (FSI) models, one with asymmetric-mapped CFN from measurements of porcine valve and the other with simplified-symmetric CFN. The FSI models are based on coupled structural and fluid dynamic solvers. The partitioned solver has nonconformal meshes and the flow is modeled by employing the Eulerian approach. The collagen in the CFNs, the surrounding elastin matrix, and the aortic sinus tissues have hyperelastic mechanical behavior. The coaptation is modeled with a master-slave contact algorithm. A full cardiac cycle is simulated by imposing the same physiological blood pressure at the upstream and downstream boundaries for both models. The mapped case showed highly asymmetric valve kinematics and hemodynamics even though there were only small differences between the opening areas and cardiac outputs of the two cases. The regions with a less dense fiber network are more prone to damage since they are subjected to higher principal stress in the tissues and a higher level of flow shear stress. This asymmetric flow leeward of the valve might damage not only the valve itself but also the ascending aorta.
Collapse
|
26
|
Bogdanska J, Sundström M, Bergström U, Borg D, Abedi-Valugerdi M, Bergman Å, DePierre J, Nobel S. Tissue distribution of 35S-labelled perfluorobutanesulfonic acid in adult mice following dietary exposure for 1-5 days. CHEMOSPHERE 2014; 98:28-36. [PMID: 24238775 DOI: 10.1016/j.chemosphere.2013.09.062] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2012] [Revised: 09/16/2013] [Accepted: 09/21/2013] [Indexed: 05/18/2023]
Abstract
Perfluorobutanesulfonyl fluoride (PBSF) has been introduced as a replacement for its eight-carbon homolog perfluorooctanesulfonyl fluoride (POSF) in the manufacturing of fluorochemicals. Fluorochemicals derived from PBSF may give rise to perfluorobutanesulfonic acid (PFBS) as a terminal degradation product. Although basic mammalian toxicokinetic data exist for PFBS, information on its tissue distribution has only been reported in one study focused on rat liver. Therefore, here we characterized the tissue distribution of PFBS in mice in the same manner as we earlier examined its eight-carbon homolog perfluorooctanesulfonate (PFOS) to allow direct comparisons. Following dietary exposure of adult male C57/BL6 mice for 1, 3 or 5d to 16 mg (35)S-PFBS kg(-1) d(-1), both scintillation counting and whole-body autoradiography (WBA) revealed the presence of PFBS in all of the 20 different tissues examined, demonstrating its ability to leave the bloodstream and enter tissues. After 5d of treatment the highest levels were detected in liver, gastrointestinal tract, blood, kidney, cartilage, whole bone, lungs and thyroid gland. WBA revealed relatively high levels of PFBS in male genital organs as well, with the exception of the testis. The tissue levels increased from 1 to 3 d of exposure but appeared thereafter to level-off in most cases. The estimated major body compartments were whole bone, liver, blood, skin and muscle. This exposure to PFBS resulted in 5-40-fold lower tissue levels than did similar exposure to PFOS, as well as in a different pattern of tissue distribution, including lower levels in liver and lungs relative to blood.
Collapse
Affiliation(s)
- Jasna Bogdanska
- Department of Biochemistry and Biophysics, Stockholm University, SE-10691 Stockholm, Sweden.
| | - Maria Sundström
- Environmental Chemistry Unit, Department of Materials and Environmental Chemistry, Stockholm University, SE-10691 Stockholm, Sweden.
| | - Ulrika Bergström
- Department of Environmental Toxicology, Uppsala University, SE-75236 Uppsala, Sweden
| | - Daniel Borg
- Institute of Environmental Medicine, Karolinska Institutet, SE-17177 Stockholm, Sweden.
| | | | - Åke Bergman
- Environmental Chemistry Unit, Department of Materials and Environmental Chemistry, Stockholm University, SE-10691 Stockholm, Sweden.
| | - Joseph DePierre
- Department of Biochemistry and Biophysics, Stockholm University, SE-10691 Stockholm, Sweden.
| | - Stefan Nobel
- Department of Molecular Medicine and Surgery, Section of Integrative Physiology, Karolinska Institute, SE-17177 Stockholm, Sweden.
| |
Collapse
|
27
|
Wang Z, Fang L, Shi W, Wang K, Wang D. Whistle characteristics of free-ranging Indo-Pacific humpback dolphins (Sousa chinensis) in Sanniang Bay, China. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 133:2479-2489. [PMID: 23556612 DOI: 10.1121/1.4794390] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Broadband recording systems were adapted to characterize the whistle characteristics of free-ranging Indo-Pacific humpback dolphins (Sousa chinensis) in Sanniang Bay, China. A total of 4630 whistles were recorded, of which 2651 with legible contours and relatively good signal-to-noise ratios were selected for statistical analysis. Of the six tonal types (i.e., flat, down, rise, convex, U-shaped, and sine), flat (N = 1426; 39.45%) was the most predominant, followed by down (N = 754; 23.35%) and rise (N = 489; 12.34%). The whistles showed a short duration (mean ± SD: 370.19 ± 285.61 ms; range: 29-2923 ms), a broad frequency range (fundamental contour ranged from 0.52 to 33 kHz), and two harmonics (mean ± SD: 1.90 ± 2.74, with the maximum frequency of harmonics beyond 96 kHz). Whistles without gaps and stairs accounted for 76.7% and 86.4%, respectively. No significant interspecies differences in frequency parameters were observed compared with S. teuszii, which is inconsistent with morphological taxonomies but confirms phylogenetic results, thus suggesting a close relation between Chinese S. chinensis and Atlantic S. teuszii. Significant intra- and interspecific differences in the genus Sousa were also observed, indicating that animal vocalization may not be limited by genetically determined traits but could also be a function of local habitat adaptation.
Collapse
Affiliation(s)
- Zhitao Wang
- The Key Laboratory of Aquatic Biodiversity and Conservation of Chinese Academy of Sciences, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, People's Republic of China
| | | | | | | | | |
Collapse
|
28
|
Marom G, Kim HS, Rosenfeld M, Raanani E, Haj-Ali R. Fully coupled fluid-structure interaction model of congenital bicuspid aortic valves: effect of asymmetry on hemodynamics. Med Biol Eng Comput 2013; 51:839-48. [PMID: 23475570 DOI: 10.1007/s11517-013-1055-4] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2012] [Accepted: 02/25/2013] [Indexed: 11/30/2022]
Abstract
A bicuspid aortic valve (BAV) is a congenital cardiac disorder where the valve consists of only two cusps instead of three, as in a normal tricuspid valve (TAV). Although 97 % of BAVs include asymmetric cusps, little or no prior studies have investigated the blood flow through a three-dimensional BAV and root. The aim of the present study was to characterize the effect of asymmetric BAV on the blood flow using fully coupled fluid-structure interaction (FSI) models with improved boundary conditions and tissue properties. This study presents four FSI models, including a native TAV, asymmetric BAVs with or without a raphe, and an almost symmetric BAV. Cusp tissue is composed of hyperelastic finite elements with collagen fibres embedded in the elastin matrix. A full cardiac cycle is simulated by imposing the same physiological blood pressures for all the TAV and BAV models. The latter have significantly smaller opening areas compared with the TAV. Larger stress values were found in the cusps of BAVs with fused cusps, at both the systolic and diastolic phases. The asymmetric geometry caused asymmetric vortices and much larger flow shear stress on the cusps which could be a potential initiator for early valvular calcification of BAVs.
Collapse
Affiliation(s)
- Gil Marom
- School of Mechanical Engineering, The Fleischman Faculty of Engineering, Tel Aviv University, 6997801 Tel Aviv, Israel.
| | | | | | | | | |
Collapse
|
29
|
Marom G, Haj-Ali R, Rosenfeld M, Schäfers HJ, Raanani E. Aortic root numeric model: Annulus diameter prediction of effective height and coaptation in post–aortic valve repair. J Thorac Cardiovasc Surg 2013; 145:406-411.e1. [DOI: 10.1016/j.jtcvs.2012.01.080] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2011] [Revised: 01/06/2012] [Accepted: 01/24/2012] [Indexed: 10/28/2022]
|
30
|
The micron stroke hypothesis of Alzheimer's disease and dementia. Med Hypotheses 2012; 78:562-70. [PMID: 22381661 DOI: 10.1016/j.mehy.2012.01.020] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2011] [Revised: 12/15/2011] [Accepted: 01/09/2012] [Indexed: 11/22/2022]
Abstract
Alzheimer's disease as currently described in the medical literature is often more a description of dementia rather than a specific disease. In over a century of scientific work there has been no proven theory as to the precise pathogenesis of Alzheimer's disease and dementia. As there is no efficient treatment for patients with Alzheimer's disease, prevention or attenuation of the disease is of substantial value. An intricate collection of hypotheses, studies, research, and experience has made it complicated for one to completely understand this disease. The purpose of this hypothesis is to illustrate new concepts and work to link those concepts to the present understanding of an obscure disease. The search for a single unifying hypothesis on the etiology of Alzheimer's disease has been elusive. Many hypotheses associated to Alzheimer's disease have not survived their testing to become theory. Suggested here is that the elusive nature of etiology of dementia is not from one cause, but rather the causes are numerous. Medical terminology used freely for decades is rarely evaluated in the light of a new hypothesis. At the foundation of this work is the suggestion of a new medical term: Micron Strokes. The Micron Stroke Hypothesis of Alzheimer's Disease and Dementia include primary and secondary factors. The primary factors can be briefly described as baseline brain tissue, atrial fibrillation, hypercoaguable state, LDL, carotid artery stenosis, tobacco exposure, hypertension diabetes mellitus, and the presence of systemic inflammation. Dozens of secondary factors contribute to the development of dementia. Most dementia is caused by nine primary categories of factors as they interact to cause micron strokes to the brain.
Collapse
|
31
|
Marom G, Haj-Ali R, Raanani E, Schäfers HJ, Rosenfeld M. A fluid-structure interaction model of the aortic valve with coaptation and compliant aortic root. Med Biol Eng Comput 2011; 50:173-82. [PMID: 22170305 DOI: 10.1007/s11517-011-0849-5] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2011] [Accepted: 12/03/2011] [Indexed: 11/30/2022]
Abstract
While aortic valve root compliance and leaflet coaptation have significant influence on valve closure, their implications have not yet been fully evaluated. The present study developed a full fluid-structure interaction (FSI) model that is able to cope with arbitrary coaptation between the leaflets of the aortic valve during the closing phase. Two simplifications were also evaluated for the simulation of the closing phase only. One employs an FSI model with a rigid root and the other uses a "dry" (without flow) model. Numerical tests were performed to verify the model. New metrics were defined to process the results in terms of leaflet coaptation area and contact pressure. The axial displacement of the leaflets, closure time and coaptation parameters were similar in the two FSI models, whereas the dry model, with imposed uniform load on the leaflets, produced larger coaptation area and contact pressure, larger axial displacement and faster closure time compared with the FSI model. The differences were up to 30% in the coaptation area, 55% in the contact pressure and 170% in the closure time. Consequently, an FSI model should be used to accurately resolve the kinematics of the aortic valve and leaflet coaptation details during the end-closing stage.
Collapse
Affiliation(s)
- Gil Marom
- The Fleischman Faculty of Engineering, School of Mechanical Engineering, Tel Aviv University, Ramat Aviv, 69978 Tel Aviv, Israel.
| | | | | | | | | |
Collapse
|
32
|
Jeon YJ, Kim JU, Lee HJ, Lee J, Ryu HH, Lee YJ, Kim JY. A clinical study of the pulse wave characteristics at the three pulse diagnosis positions of chon, gwan and cheok. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE 2011; 2011:904056. [PMID: 19789213 PMCID: PMC3137784 DOI: 10.1093/ecam/nep150] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2009] [Accepted: 08/30/2009] [Indexed: 02/01/2023]
Abstract
In this work, we analyze the baseline, signal strength, aortic augmentation index (AIx), radial AIx, time to reflection and P_T2 at Chon, Gwan, and Cheok, which are the three pulse diagnosis positions in Oriental medicine. For the pulse measurement, we used the SphygmoCor apparatus, which has been widely used for the evaluation of the arterial stiffness at the aorta. By two-way repeated measures analysis of variance, we tested two independent measurements for repeatability and investigated their mean differences among Chon, Gwan and Cheok. To characterize further the parameters that were shown to be different between each palpation position, we carried out Duncan's test for the multiple comparisons. The baseline and signal strength were statistically different (P < .05) among Chon, Gwan and Cheok, respectively, which supports the major hypothesis of Oriental medicine that all of the three palpation positions contain different clinical information. On the other hand, aortic AIx and time to reflection were found to be statistically different between Chon and the others, and radial AIx and P_T2 did not show any difference between pulse positions. In the clinical sense, however, the aortic AIx at each palpation position was found to fall within the 90% confidence interval of normal arterial compliance. The results of the multiple comparisons indicate that the parameters of arterial stiffness were independent of the palpation positions. This work is the first attempt to characterize quantitatively the pulse signals at Chon, Gwan and Cheok with some relevant parameters extracted from the SphygmoCor apparatus.
Collapse
Affiliation(s)
- Young J Jeon
- Constitutional Biology and Medical Engineering Research Center, Korea Institute of Oriental Medicine (KIOM), 461-24 Jeonmin-dong, Yuseong-gu, Daejeon 305-811, Republic of Korea
| | | | | | | | | | | | | |
Collapse
|
33
|
Bogdanska J, Borg D, Sundström M, Bergström U, Halldin K, Abedi-Valugerdi M, Bergman A, Nelson B, Depierre J, Nobel S. Tissue distribution of ³⁵S-labelled perfluorooctane sulfonate in adult mice after oral exposure to a low environmentally relevant dose or a high experimental dose. Toxicology 2011; 284:54-62. [PMID: 21459123 DOI: 10.1016/j.tox.2011.03.014] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2010] [Revised: 03/04/2011] [Accepted: 03/25/2011] [Indexed: 12/29/2022]
Abstract
The widespread environmental pollutant perfluorooctane sulfonate (PFOS), detected in most animal species including the general human population, exerts several effects on experimental animals, e.g., hepatotoxicity, immunotoxicity and developmental toxicity. However, detailed information on the tissue distribution of PFOS in mammals is scarce and, in particular, the lack of available information regarding environmentally relevant exposure levels limits our understanding of how mammals (including humans) may be affected. Accordingly, we characterized the tissue distribution of this compound in mice, an important experimental animal for studying PFOS toxicity. Following dietary exposure of adult male C57/BL6 mice for 1-5 days to an environmentally relevant (0.031 mg/kg/day) or a 750-fold higher experimentally relevant dose (23 mg/kg/day) of ³⁵S-PFOS, most of the radioactivity administered was recovered in liver, bone (bone marrow), blood, skin and muscle, with the highest levels detected in liver, lung, blood, kidney and bone (bone marrow). Following high daily dose exposure, PFOS exhibited a different distribution profile than with low daily dose exposure, which indicated a shift in distribution from the blood to the tissues with increasing dose. Both scintillation counting (with correction for the blood present in the tissues) and whole-body autoradiography revealed the presence of PFOS in all 19 tissues examined, with identification of thymus as a novel site for localization for PFOS and bone (bone marrow), skin and muscle as significant body compartments for PFOS. These findings demonstrate that PFOS leaves the bloodstream and enters most tissues in a dose-dependent manner.
Collapse
Affiliation(s)
- Jasna Bogdanska
- Department of Biochemistry and Biophysics, Stockholm University, SE-10691 Stockholm, Sweden.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Jauchem JR. Increased hematocrit after applications of conducted energy weapons (including TASER(®) devices) to Sus scrofa. J Forensic Sci 2011; 56 Suppl 1:S229-33. [PMID: 21198623 DOI: 10.1111/j.1556-4029.2010.01629.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Conducted energy weapons (CEWs) are used by law enforcement personnel to incapacitate individuals quickly and effectively, without intending to cause lethality. CEWs have been deployed for relatively long or repeated exposures in some cases. In laboratory animal models, central venous hematocrit has increased significantly after CEW exposure. Even limited applications (e.g., three 5-sec applications) resulted in statistically significant increases in hematocrit. Preexposure hematocrit was significantly higher in nonsurvivors versus survivors after more extreme CEW applications. The purpose of this technical note is to address specific questions that may be generated when examining these results. Comparisons among results of CEW applications, other electrical muscle stimulation, and exercise/voluntary muscle contraction are included. The anesthetized swine appears to be an acceptable animal model for studying changes in hematocrit and associated red blood cell changes. Potential detrimental effects of increased hematocrit, and considerations during law enforcement use, are discussed.
Collapse
Affiliation(s)
- James R Jauchem
- Directed Energy Bio-Effects Division, U.S. Air Force Research Laboratory, San Antonio, TX 78235, USA.
| |
Collapse
|
35
|
Lee YJ, Lee J, Kim JY. A study on characteristics of radial arteries through ultrasonic waves. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2009; 2008:2453-6. [PMID: 19163199 DOI: 10.1109/iembs.2008.4649696] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The study aims to measure and analyze the thickness and depth of blood vessel on the pulse diagnosis locations (CHON, KWAN, CHUCK) and the blood velocity through the use of ultrasonic waves (LOGIQ5PRO, GE Medical, U.S.) in order to understand the structural difference of pulse diagnosis locations. The subjects included 44 healthy men and women (22.28+/-2.62 age) considered normal in terms of Body Mass Index (BMI). The thickness and depth of the blood vessel and the blood velocity were measured three times on CHON, KWAN and CHUCK to obtain the average value.
Collapse
Affiliation(s)
- Yu-Jung Lee
- Department of Electronic Engineering, Kalsan-ri, Tangjeong-myeon, Asan-si, Chungnam, Sunmoon University, South Korea
| | | | | |
Collapse
|
36
|
Lee J, Smith N. Development and application of a one-dimensional blood flow model for microvascular networks. Proc Inst Mech Eng H 2008; 222:487-511. [PMID: 18595360 DOI: 10.1243/09544119jeim308] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Although there are many studies available in the literature on time domain modelling of one-dimensional network blood flow, the rheological properties of blood in this modelling framework have often been disregarded through the inviscid assumption. While such a simplification may be suitable for studying the larger vessels of the circulatory system, this approach cannot be taken when modelling flow in the vessels of microcirculation in which viscous effects are much more significant. In this study, a one-dimensional network blood flow model was extended to incorporate experimentally characterized properties of the non-Newtonian blood rheology, namely the reduction in the effective viscosity in thin vessels (the Fahraeus-Lindqvist effect) and the non-proportional splitting of red blood cells at junctions (phase separation). The numerical implementation was based on the high-order finite element technique with implicit time integration, necessitated by the decreasing length of vessels on this scale. Investigations in small networks indicated that the diameter dependence of viscosity has a major impact on the overall flow and should be included in small vessel networks. However, since phase separation effects are significant only in small arterioles of diameter less than 40 microm and require significant additional complexities in computation, they may be neglected for networks that do not contain these vessels without causing a large error. The proposed technique was applied to a coronary vascular subnetwork extracted from micro computed tomography scans of a rat heart consisting of approximately 2500 segments and proved to be computationally efficient, thus providing a potential foundation for applying this model to future physiological investigations.
Collapse
Affiliation(s)
- J Lee
- Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | | |
Collapse
|
37
|
Libgot-Callé R, Ossant F, Gruel Y, Lermusiaux P, Patat F. High frequency ultrasound device to investigate the acoustic properties of whole blood during coagulation. ULTRASOUND IN MEDICINE & BIOLOGY 2008; 34:252-264. [PMID: 18077082 DOI: 10.1016/j.ultrasmedbio.2007.06.018] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2006] [Revised: 06/08/2007] [Accepted: 06/20/2007] [Indexed: 05/25/2023]
Abstract
This study was designed to investigate the changes in acoustic properties of whole blood during the coagulation process. High frequency (from 20 to 40 MHz) ultrasound parameters were measured both in double transmission (DT) and backscattering (BS) mode to assess sound velocity and backscatter coefficient, respectively. The integrated backscatter coefficient (IBC) and the effective scatterer size (ESS) were deducted from the backscatter coefficient. Measurements were performed on whole blood samples collected from 12 healthy volunteers. During the blood clotting process (2 h observation), acoustic parameters were measured with 15 s time resolution for the transmission parameter and 5 s (for the 5 first min) and 30 s (for the end of the observation time) for the backscattering parameters. The results obtained clearly showed that simultaneous measurements of parameters in DT and BS modes are able to identify several stages during the in vitro blood clotting process. In particular, red blood cell (RBC) aggregation can be described from the backscattering parameters and liquid-gel transition phase of blood from the sound velocity. Intra- and inter-individual dispersion of these parameters were also measured and discussed.
Collapse
Affiliation(s)
- Rachel Libgot-Callé
- Université François Rabelais Tours, Laboratoire Ultrasons Signaux Instrumentation, CNRS FRE 2448, Tours, France.
| | | | | | | | | |
Collapse
|
38
|
Huang CC, Wang SH. Assessment of blood coagulation under various flow conditions with ultrasound backscattering. IEEE Trans Biomed Eng 2008; 54:2223-30. [PMID: 18075038 DOI: 10.1109/tbme.2007.908334] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Several in vitro studies have employed ultrasonic techniques to detect varying properties of coagulating blood under static or stirred conditions. Most of those studies mainly addressed on the development and feasibility of modalities and however were not fully considering the effect of blood flow. To better elucidate this issue, ultrasonic backscattering were measured from the coagulating porcine blood circulated in a mock flow loop with various steady laminar flows at mean shear rates from 10 to 100 s(-1). A 3 ml of 0.5 M CaCl2 solution for inducing blood coagulation was added to that of 30 ml blood circulated in the conduit. For each measurement carried out with a 10-MHz transducer, backscattered signals digitized at 100-MHz sampling frequency were acquired for a total of 20 min at temporal resolution of 50 A-lines per s. The integrated backscatter (IB) was calculated for assessing backscattering properties of coagulating blood. The results show that blood coagulation tended to be increased corresponding to the addition of CaCl2 solution: the IB was increased approximately 6.1 +/- 0.6 (mean +/- standard deviation), 5.4 +/- 0.9, and 4.5 +/- 1.2 dB at 310 +/- 62, 420 +/- 88, and 610 +/- 102 s associated with mean shear rates of 10, 40, and 100 s(-1), respectively. The rate of increasing IB for evaluating the growth of clot was estimated to be 0.075 +/- 0.017, 0.052 +/- 0.027, and 0.038 +/- 0.012 delta dB delta s(-1) corresponding to the increase of mean shear rates. These results consistently demonstrate that higher shear rate tends to prolong the duration for the flowing blood to be coagulated and to decrease the rate of IB. Moreover, the laminar flow was changed to turbulent flow during that the blood was clotting discerned by spatial variations of ultrasound backscattering in the conduit. All these results validate that ultrasound backscattering is feasible to be utilized for detecting and assessing blood coagulation under dynamic conditions.
Collapse
Affiliation(s)
- Chih-Chung Huang
- Department of Biomedical Engineering, Chung Yuan Christian University, Chung Li 32023, Taiwan, ROC
| | | |
Collapse
|
39
|
Morisaka T, Connor RC. Predation by killer whales (Orcinus orca) and the evolution of whistle loss and narrow-band high frequency clicks in odontocetes. J Evol Biol 2007; 20:1439-58. [PMID: 17584238 DOI: 10.1111/j.1420-9101.2007.01336.x] [Citation(s) in RCA: 103] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A disparate selection of toothed whales (Odontoceti) share striking features of their acoustic repertoires including the absence of whistles and high frequency but weak (low peak-to-peak source level) clicks that have a relatively long duration and a narrow bandwidth. The non-whistling, high frequency click species include members of the family Phocoenidae, members of one genus of delphinids, Cephalorhynchus, the pygmy sperm whale, Kogia breviceps, and apparently the sole member of the family Pontoporiidae. Our review supports the 'acoustic crypsis' hypothesis that killer whale predation risk was the primary selective factor favouring an echolocation and communication system in cephalorhynchids, phocoenids and possibly Pontoporiidae and Kogiidae restricted to sounds that killer whales hear poorly or not at all (< 2 and > 100 kHz).
Collapse
Affiliation(s)
- T Morisaka
- Laboratory of Animal Ecology, Department of Zoology, Graduate School of Science, Kyoto University, Kyoto, Japan.
| | | |
Collapse
|
40
|
Huang CC, Wang SH, Tsui PH. Detection of blood coagulation and clot formation using quantitative ultrasonic parameters. ULTRASOUND IN MEDICINE & BIOLOGY 2005; 31:1567-73. [PMID: 16286034 DOI: 10.1016/j.ultrasmedbio.2005.07.003] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2005] [Revised: 06/27/2005] [Accepted: 07/07/2005] [Indexed: 05/05/2023]
Abstract
The ultrasonic parameters of sound velocity, attenuation and integrated backscatter were applied to detect the process of coagulation and clot formation in porcine blood. Fresh porcine blood containing 15% anticoagulant solution was collected. Blood samples with a hematocrit of 45% were obtained by reconstituting the packed erythrocytes with the separated plasma for ultrasound measurements performed with a 10-MHz focused transducer. A 24-mL aliquot of blood was placed in a container and 12 mL of 0.2 mol/L CaCl2 solution was added to induce clot formation. In each measurement, radio-frequency signals of the blood digitized at 100 MHz were collected for 50 min at a temporal resolution of 1 A-line per s. Results showed that all of the parameters increased within the initial 3 min and, then, immediately decreased dramatically as the CaCl2 solution was added. Subsequently, the sound velocity gradually increased with time and the integrated backscatter and attenuation increased in accordance with blood coagulation until approximately 500 and 2600 s, respectively. The integrated backscatter, attenuation and sound velocity can be divided into different stages, including red cell aggregation, reduction in hematocrit, blood coagulation and clot formation, corresponding to variations in the physical and chemical properties of the blood. The integrated backscatter, attenuation and sound velocity increased because of the changes in blood properties during the process of coagulation and clot formation: by 8.2 dB, 0.65 dB/cm, and 0.6%, respectively. These results provide a feasibility for further applying ultrasonic parameters to in vivo monitor the progress of clotting and thrombosis research.
Collapse
Affiliation(s)
- Chih-Chung Huang
- Department of Biomedical Engineering, Chung Yuan Christian University, Chung Li, Taiwan
| | | | | |
Collapse
|
41
|
Gracewski SM, Miao H, Dalecki D. Ultrasonic excitation of a bubble near a rigid or deformable sphere: implications for ultrasonically induced hemolysis. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2005; 117:1440-7. [PMID: 15807031 DOI: 10.1121/1.1858211] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
A number of independent studies have reported increased ultrasound bioeffects, such as hemolysis and hemorrhage, when ultrasound contrast agents are present. To better understand the role of cavitation in these bioeffects, one- and two-dimensional models have been developed to investigate the interactions between ultrasonically excited bubbles and model "cells." First, a simple one-dimensional model based on the Rayleigh-Plesset equation was developed to estimate upper bounds for strain, strain rate, and areal expansion of a simulated red blood cell. Then, two-dimensional boundary element models were developed (with DynaFlow Inc.) to obtain simulations of asymmetric bubble dynamics in the presence of rigid and deformable spheres. The deformable spherical "cell" was modeled using Tait's equation of state for water, with a membrane approximated by surface tension that increases linearly with areal expansion. The presence of a rigid or deformable sphere had little effect on the bubble expansion, but caused an asymmetric collapse and jetting for the conditions considered. Predicted membrane areal expansions were found to be below critical values for hemolysis reported in the literature for the cases considered near the inertial cavitation threshold.
Collapse
Affiliation(s)
- Sheryl M Gracewski
- Mechanical Engineering, Biomedical Engineering, and Rochester Center for Biomedical Ultrasound, University of Rochester, Rochester, New York 14627, USA.
| | | | | |
Collapse
|