Todesco M, Lezziero G, Gerosa G, Bagno A. Polymeric Heart Valves: Do They Represent a Reliable Alternative to Current Prosthetic Devices? Polymers (Basel) 2025; 17:557. [PMID: 40076051 PMCID: PMC11902043 DOI: 10.3390/polym17050557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2025] [Revised: 02/05/2025] [Accepted: 02/13/2025] [Indexed: 03/14/2025] Open
Abstract
With the increasing number of people suffering from heart valve diseases (e.g., stenosis and/or insufficiency), the attention paid to prosthetic heart valves has grown significantly. Developing a prosthetic device that fully replaces the functionality of the native valve remains a huge challenge. Polymeric heart valves (PHVs) represent an appealing option, offering the potential to combine the robustness of mechanical valves with the enhanced biocompatibility of bioprosthetic ones. Over the years, novel biomaterials (such as promising new polymers and nanocomposites) and innovative designs have been explored for possible applications in manufacturing PHVs. This work provides a comprehensive overview of PHVs' evolution in terms of materials, design, and fabrication techniques, including in vitro and in vivo studies. Moreover, it addresses the drawbacks associated with PHV implementation, such as their limited biocompatibility and propensity for sudden failure in vivo. Future directions for further development are presented. Notably, PHVs can be particularly relevant for transcatheter application, the most recent minimally invasive approach for heart valve replacement. Despite current challenges, PHVs represent a promising area of research with the potential to revolutionize the treatment of heart valve diseases, offering more durable and less invasive solutions for patients.
Collapse
Affiliation(s)
- Martina Todesco
- Department of Industrial Engineering, University of Padua, 35131 Padua, Italy; (M.T.); (G.L.)
| | - Gianluca Lezziero
- Department of Industrial Engineering, University of Padua, 35131 Padua, Italy; (M.T.); (G.L.)
| | - Gino Gerosa
- Department of Cardiac, Thoracic Vascular Sciences and Public Health, University of Padua, 35128 Padua, Italy;
| | - Andrea Bagno
- Department of Industrial Engineering, University of Padua, 35131 Padua, Italy; (M.T.); (G.L.)
| |
Collapse
|
2
|
Contorno E, Javed H, Steen L, Lowery J, Zaghw A, Duerksen A, Henrich-Lobo R, Reemtsen B, Rajab TK. Options for pediatric heart valve replacement. Future Cardiol 2025; 21:47-52. [PMID: 39781900 PMCID: PMC11812425 DOI: 10.1080/14796678.2024.2445402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2024] [Accepted: 12/18/2024] [Indexed: 01/12/2025] Open
Abstract
Heart valve replacement is indicated for children with irreparable heart valve disease. These replacements come in a variety of forms including mechanical, xenograft tissue, allograft tissue, and autograft tissue valves. These options each have unique benefits and risks profiles. Mechanical valves are the most structurally durable; however, they represent significant thrombogenic risks and require anticoagulant therapy. Xenograft and homograft tissue valves do not carry the thrombogenic risks found with mechanical valves but also do not have the structural integrity of mechanical valves. Importantly, neither of these options allows for the somatic growth, requiring serial reoperation to implant upsized valves. Autograft implantation and partial heart transplantation each allow for the implantation of growing valves; however, autografts require for either a mechanical or bioprosthetic valve to be fitted into another valve position and PHT requires immunosuppressive medication to allow for the growth of the valve. In summary, outcomes of valve implantation in the pediatric population are significantly subpar compared to the outcomes enjoyed by the adult population. To remedy this, further innovation is needed in heart valve replacement technology.
Collapse
Affiliation(s)
- Eli Contorno
- Department of Cardiovascular Surgery, Arkansas Children’s Hospital, Little Rock, AR, USA
- Center for Translational Pediatric Research, Arkansas Children’s Research Institute, Little Rock, AR, USA
| | - Herra Javed
- Department of Cardiovascular Surgery, Arkansas Children’s Hospital, Little Rock, AR, USA
- Center for Translational Pediatric Research, Arkansas Children’s Research Institute, Little Rock, AR, USA
| | - Louis Steen
- Department of Cardiovascular Surgery, Arkansas Children’s Hospital, Little Rock, AR, USA
| | - John Lowery
- Center for Translational Pediatric Research, Arkansas Children’s Research Institute, Little Rock, AR, USA
| | - Ahmed Zaghw
- Department of Cardiovascular Anesthesia, Arkansas Children’s Hospital, Little Rock, AR, USA
| | - Ali Duerksen
- Department of Cardiovascular Surgery, Arkansas Children’s Hospital, Little Rock, AR, USA
| | - Rodolfo Henrich-Lobo
- Department of Pathology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Brian Reemtsen
- Department of Cardiovascular Surgery, Arkansas Children’s Hospital, Little Rock, AR, USA
| | - T. Konrad Rajab
- Department of Cardiovascular Surgery, Arkansas Children’s Hospital, Little Rock, AR, USA
| |
Collapse
|
3
|
Hofferberth SC, Kelley T, Armstrong AK, Heyninck-Jantz C, Maiorano A, Colson M, Schoen FJ, Wu C, Ibrahim N, Tretter JT, Mueller MD, Bianco RW, Carney JP, Behr L, Breuer CK, Beith J, Cox M, Feins EN, Vang E, Wood L, Tranquillo RT, Lim DS, Taylor AM, Redington A, Cheatham JP, McElhinney DB, Del Nido PJ, Yoganathan A. Challenges in the Development and Evaluation of Pediatric Heart Valve Technologies. Ann Thorac Surg 2024:S0003-4975(24)01045-2. [PMID: 39674526 DOI: 10.1016/j.athoracsur.2024.11.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2024] [Revised: 09/20/2024] [Accepted: 11/09/2024] [Indexed: 12/16/2024]
Abstract
BACKGROUND In October 2022, the Heart Valve Collaboratory and United States Food and Drug Administration convened a global multidisciplinary workshop to address the unmet clinical need to promote and accelerate the development of pediatric-specific heart valve technologies. METHODS The Pediatric Heart Valve Global Multidisciplinary Workshop was convened in October 2022. Key stakeholders, including expert clinicians in pediatric cardiology and cardiac surgery, valve manufacturers, engineers, and scientists were assembled to review the current state of the art, discuss unique challenges in the premarket and postmarket evaluation of pediatric valve therapies, and highlight emerging technologies that show potential to address some of the key unmet needs of children with valve disease. RESULTS The workshop highlighted the tremendous clinical need to develop a new framework for developing and evaluating pediatric-specific heart valve therapies. CONCLUSIONS This report summarizes the proceedings of the workshop and outlines the key considerations for developing a new framework for evaluating novel pediatric heart valve therapies.
Collapse
Affiliation(s)
- Sophie C Hofferberth
- Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts; Autus Valve Technologies, Inc, Boston, Massachusetts
| | | | - Aimee K Armstrong
- Division of Cardiology, The Heart Center, Nationwide Children's Hospital, The Ohio State University College of Medicine, Columbus, Ohio
| | | | | | | | - Frederick J Schoen
- Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts
| | - Changfu Wu
- Center for Devices and Radiological Health, United States Food & Drug Administration, Silver Spring, Maryland
| | - Nicole Ibrahim
- Center for Devices and Radiological Health, United States Food & Drug Administration, Silver Spring, Maryland
| | - Justin T Tretter
- Department of Pediatric Cardiology, Cleveland Clinic Children's and The Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio
| | | | | | | | - Luc Behr
- Veranex, Inc, Raleigh, North Carolina
| | | | | | | | - Eric N Feins
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts
| | - Eric Vang
- Medtronic Structural Heart, Lafayette, Colorado
| | - Larry Wood
- Edwards Lifesciences, Irvine, California
| | | | - D Scott Lim
- University of Virginia, Charlottesville, Virginia
| | - Andrew M Taylor
- University College London, Great Ormond Street Hospital for Children, London, United Kingdom
| | | | | | | | - Pedro J Del Nido
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts
| | - Ajit Yoganathan
- Georgia Institute of Technology and Emory University, Atlanta, Georgia.
| |
Collapse
|
4
|
Giorgianni AE, Ventura G, Hollmann J, Williams C. Blueprint for a Semi-automated Image Processing Tool to Characterize Stent Features: Application to a Pediatric Growth-Adaptive Stent. Ann Biomed Eng 2024; 52:2948-2957. [PMID: 38861042 DOI: 10.1007/s10439-024-03553-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2024] [Accepted: 05/28/2024] [Indexed: 06/12/2024]
Abstract
The goal of this work was to develop a general blueprint for a semi-automated image processing tool (SIPT) to measure small, complex features of stent prototypes that can replace the current gold standard of manual measurements. The stents were designed using CAD software and manufactured via laser cutting. Stent prototypes were imaged using a Keyence microscope in top and side view orientations. The SIPT algorithm was developed in MATLAB to extract and measure 4 dimensions of the stent (inner and outer diameter, spring bend outer radius, spring bend width). The same dimensions were also manually measured by an experienced metrology technician as a gold standard comparison. We successfully made over 5000 unique measurements across the 4 key dimensions of 15 stents using the SIPT algorithm. Compared to the gold standard manual method, SIPT reduced measurement time by nearly 90% and increased the total number of measurements captured by over 2300%. The two one-sided test and Bland-Altman analysis demonstrated that SIPT achieved equivalency against the manual method of measurement for all 4 dimensions. In summary, we found that our SIPT software could be used to replace manual measurements and provided substantial time savings with consistent accuracy. Overall, this paper presents a generalizable workflow to isolate and measure critical features of stent prototypes that we believe will provide a valuable, cost-effective tool to other medical device designers seeking to rapidly iterate on unique stent designs or other manufactured parts with small and complex structures.
Collapse
Affiliation(s)
- Ava E Giorgianni
- Positioning, Navigation, and Timing Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, USA
| | - Giselle Ventura
- Mechanical Engineering Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, USA
| | - Joseph Hollmann
- Positioning, Navigation, and Timing Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, USA
| | - Corin Williams
- Bioengineering Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, USA.
| |
Collapse
|
5
|
Xu C, Chen Y, Zhao S, Li D, Tang X, Zhang H, Huang J, Guo Z, Liu W. Mechanical Regulation of Polymer Gels. Chem Rev 2024; 124:10435-10508. [PMID: 39284130 DOI: 10.1021/acs.chemrev.3c00498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/26/2024]
Abstract
The mechanical properties of polymer gels devote to emerging devices and machines in fields such as biomedical engineering, flexible bioelectronics, biomimetic actuators, and energy harvesters. Coupling network architectures and interactions has been explored to regulate supportive mechanical characteristics of polymer gels; however, systematic reviews correlating mechanics to interaction forces at the molecular and structural levels remain absent in the field. This review highlights the molecular engineering and structural engineering of polymer gel mechanics and a comprehensive mechanistic understanding of mechanical regulation. Molecular engineering alters molecular architecture and manipulates functional groups/moieties at the molecular level, introducing various interactions and permanent or reversible dynamic bonds as the dissipative energy. Molecular engineering usually uses monomers, cross-linkers, chains, and other additives. Structural engineering utilizes casting methods, solvent phase regulation, mechanochemistry, macromolecule chemical reactions, and biomanufacturing technology to construct and tailor the topological network structures, or heterogeneous modulus compositions. We envision that the perfect combination of molecular and structural engineering may provide a fresh view to extend exciting new perspectives of this burgeoning field. This review also summarizes recent representative applications of polymer gels with excellent mechanical properties. Conclusions and perspectives are also provided from five aspects of concise summary, mechanical mechanism, biofabrication methods, upgraded applications, and synergistic methodology.
Collapse
Affiliation(s)
- Chenggong Xu
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China
- College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yi Chen
- Key Laboratory of Instrumentation Science and Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030051, China
| | - Siyang Zhao
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China
- College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Deke Li
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China
- School of materials engineering, Lanzhou Institute of Technology, Lanzhou 730000, China
| | - Xing Tang
- Hubei Collaborative Innovation Centre for Advanced Organic Chemical Materials and Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubeu University, Wuhan 430062, China
| | - Haili Zhang
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China
- Hubei Collaborative Innovation Centre for Advanced Organic Chemical Materials and Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubeu University, Wuhan 430062, China
| | - Jinxia Huang
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China
| | - Zhiguang Guo
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China
- Hubei Collaborative Innovation Centre for Advanced Organic Chemical Materials and Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubeu University, Wuhan 430062, China
| | - Weimin Liu
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China
| |
Collapse
|
6
|
Carney JP, Bianco RW. Multimodal preoperative imaging for transcatheter mitral valve replacement in the domestic sheep model. Sci Rep 2024; 14:11745. [PMID: 38778204 PMCID: PMC11111800 DOI: 10.1038/s41598-024-62646-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 05/20/2024] [Indexed: 05/25/2024] Open
Abstract
Preclinical in vivo evaluation is an essential step in the progression of new cardiac devices into patient use, with studies predominantly performed in the domestic sheep model. A growing area of interest in cardiac device development is transcatheter mitral valve replacement (TMVR). Clinically, multimodal imaging, or computed tomography (CT) and echocardiography (echo) are used extensively to preoperatively determine mitral valve morphology prior to an intervention, but there is no description on how these modalities can be implemented to support preclinical studies. The purpose of this study is to apply clinically relevant CT and echo acquisition and assessment techniques to a large group of naive research sheep in order to analyze and report modality-related effects on mitral valve dimensional reference intervals in the sheep model. To this end, fifty-five adult domestic sheep underwent preoperative CT and echo exams and resultant images were analyzed using a landmark-based multiplanar measurement protocol and compiled into a master dataset for statistical analysis. We found moderate agreement between CT and echo-derived measurements of the mitral valve in sheep and propose the first clinically-relevant dimensional indices for the sheep's naive mitral valve which can be used to guide future studies evaluating novel TMVR devices. This study is the first of its kind in proposing a reproducible method for detailed examination of the mitral valve in the sheep model using clinically-relevant multimodal imaging. As in patients, CT and echo can reveal accurate native mitral valve dimensions in the sheep prior to preclinical TMVR studies.
Collapse
Affiliation(s)
- John P Carney
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota Minneapolis, 425 East River Parkway KE B18, Minneapolis, MN, 55455, USA.
| | - Richard W Bianco
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota Minneapolis, 425 East River Parkway KE B18, Minneapolis, MN, 55455, USA
| |
Collapse
|
7
|
黄 伟, 李 维, 刘 宝. [Effects of freeze-drying bovine pericardium using a combination of polyethylene glycol and trehalose]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2024; 41:368-375. [PMID: 38686419 PMCID: PMC11058504 DOI: 10.7507/1001-5515.202311035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 02/25/2024] [Indexed: 05/02/2024]
Abstract
The freeze-drying is a technology that preserves biological samples in a dry state, which is beneficial for storage, transportation, and cost saving. In this study, the bovine pericardium was treated with a freeze-drying protectant composed of polyethylene glycol (PEG) and trehalose (Tre), and then freeze-dried. The results demonstrated that the mechanical properties of the pericardium treated with PEG + 10% w/v Tre were superior to those of the pericardium fixed with glutaraldehyde (GA). The wet state water content of the rehydrated pericardium, determined using the Karl Fischer method, was (74.81 ± 1.44)%, which was comparable to that of the GA-fixed pericardium. The dry state water content was significantly reduced to (8.64 ± 1.52)%, indicating effective dehydration during the freeze-drying process. Differential scanning calorimetry (DSC) testing revealed that the thermal shrinkage temperature of the pericardium was (84.96 ± 0.49) ℃, higher than that of the GA-fixed pericardium (83.14 ± 0.11) ℃, indicating greater thermal stability. Fourier transform infrared spectroscopy (FTIR) results showed no damage to the protein structure during freeze-drying. Hematoxylin and eosin (HE) staining demonstrated that the freeze-drying process reduced pore formation, prevented ice crystal growth, and resulted in a tighter arrangement of tissue fibers. The frozen-dried bovine pericardium was subjected to tests for cell viability and hemolysis rate. The results revealed a cell proliferation rate of (77.87 ± 0.49)%, corresponding to a toxicity grade of 1. Additionally, the hemolysis rate was (0.17 ± 0.02)%, which is below the standard of 5%. These findings indicated that the frozen-dried bovine pericardium exhibited satisfactory performance in terms of cytotoxicity and hemolysis, thus meeting the relevant standards. In summary, the performance of the bovine pericardium treated with PEG + 10% w/v Tre and subjected to freeze-drying could meet the required standards.
Collapse
Affiliation(s)
- 伟 黄
- 上海理工大学 生物系统热科学研究所(上海 200093)Institute of Biothermal Science and Technology, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China
- 上海市肿瘤能量治疗技术与器械协同创新中心(上海 200093)Shanghai Co-innovation Center for Energy Therapy of Tumors, Shanghai 200093, P. R. China
- 上海市生物资源低温保存技术服务平台(上海 200093)Shanghai Technical Service Platform for Cryopreservation of Biological Resources, Shanghai 200093, P. R. China
| | - 维杰 李
- 上海理工大学 生物系统热科学研究所(上海 200093)Institute of Biothermal Science and Technology, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China
- 上海市肿瘤能量治疗技术与器械协同创新中心(上海 200093)Shanghai Co-innovation Center for Energy Therapy of Tumors, Shanghai 200093, P. R. China
- 上海市生物资源低温保存技术服务平台(上海 200093)Shanghai Technical Service Platform for Cryopreservation of Biological Resources, Shanghai 200093, P. R. China
| | - 宝林 刘
- 上海理工大学 生物系统热科学研究所(上海 200093)Institute of Biothermal Science and Technology, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China
- 上海市肿瘤能量治疗技术与器械协同创新中心(上海 200093)Shanghai Co-innovation Center for Energy Therapy of Tumors, Shanghai 200093, P. R. China
- 上海市生物资源低温保存技术服务平台(上海 200093)Shanghai Technical Service Platform for Cryopreservation of Biological Resources, Shanghai 200093, P. R. China
| |
Collapse
|
8
|
Wang J, Deng G, Wang S, Li S, Song P, Lin K, Xu X, He Z. Enhancing regenerative medicine: the crucial role of stem cell therapy. Front Neurosci 2024; 18:1269577. [PMID: 38389789 PMCID: PMC10881826 DOI: 10.3389/fnins.2024.1269577] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Accepted: 01/23/2024] [Indexed: 02/24/2024] Open
Abstract
Stem cells offer new therapeutic avenues for the repair and replacement of damaged tissues and organs owing to their self-renewal and multipotent differentiation capabilities. In this paper, we conduct a systematic review of the characteristics of various types of stem cells and offer insights into their potential applications in both cellular and cell-free therapies. In addition, we provide a comprehensive summary of the technical routes of stem cell therapy and discuss in detail current challenges, including safety issues and differentiation control. Although some issues remain, stem cell therapy demonstrates excellent potential in the field of regenerative medicine and provides novel tactics and methodologies for managing a wider spectrum of illnesses and traumas.
Collapse
Affiliation(s)
- Jipeng Wang
- Department of Gastrointestinal Surgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Gang Deng
- Department of Neurology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Shuyi Wang
- Department of Gastrointestinal Surgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Shuang Li
- Department of Otorhinolaryngology-Head and Neck Surgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Peng Song
- Department of Otorhinolaryngology-Head and Neck Surgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Kun Lin
- Department of Otorhinolaryngology-Head and Neck Surgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Xiaoxiang Xu
- Department of Otorhinolaryngology-Head and Neck Surgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Zuhong He
- Department of Otorhinolaryngology-Head and Neck Surgery, Zhongnan Hospital of Wuhan University, Wuhan, China
| |
Collapse
|
9
|
Boehm CA, Donay C, Lubig A, Ruetten S, Sesa M, Fernández-Colino A, Reese S, Jockenhoevel S. Bio-Inspired Fiber Reinforcement for Aortic Valves: Scaffold Production Process and Characterization. Bioengineering (Basel) 2023; 10:1064. [PMID: 37760166 PMCID: PMC10525898 DOI: 10.3390/bioengineering10091064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 09/04/2023] [Accepted: 09/07/2023] [Indexed: 09/29/2023] Open
Abstract
The application of tissue-engineered heart valves in the high-pressure circulatory system is still challenging. One possible solution is the development of biohybrid scaffolds with textile reinforcement to achieve improved mechanical properties. In this article, we present a manufacturing process of bio-inspired fiber reinforcement for an aortic valve scaffold. The reinforcement structure consists of polyvinylidene difluoride monofilament fibers that are biomimetically arranged by a novel winding process. The fibers were embedded and fixated into electrospun polycarbonate urethane on a cylindrical collector. The scaffold was characterized by biaxial tensile strength, bending stiffness, burst pressure and hemodynamically in a mock circulation system. The produced fiber-reinforced scaffold showed adequate acute mechanical and hemodynamic properties. The transvalvular pressure gradient was 3.02 ± 0.26 mmHg with an effective orifice area of 2.12 ± 0.22 cm2. The valves sustained aortic conditions, fulfilling the ISO-5840 standards. The fiber-reinforced scaffold failed in a circumferential direction at a stress of 461.64 ± 58.87 N/m and a strain of 49.43 ± 7.53%. These values were above the levels of tested native heart valve tissue. Overall, we demonstrated a novel manufacturing approach to develop a fiber-reinforced biomimetic scaffold for aortic heart valve tissue engineering. The characterization showed that this approach is promising for an in situ valve replacement.
Collapse
Affiliation(s)
- Christian A. Boehm
- Department of Biohybrid & Medical Textiles (BioTex), AME Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Forckenbeckstr. 55, 52074 Aachen, Germany; (C.A.B.); (C.D.); (A.L.); (A.F.-C.)
| | - Christine Donay
- Department of Biohybrid & Medical Textiles (BioTex), AME Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Forckenbeckstr. 55, 52074 Aachen, Germany; (C.A.B.); (C.D.); (A.L.); (A.F.-C.)
| | - Andreas Lubig
- Department of Biohybrid & Medical Textiles (BioTex), AME Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Forckenbeckstr. 55, 52074 Aachen, Germany; (C.A.B.); (C.D.); (A.L.); (A.F.-C.)
| | - Stephan Ruetten
- Electron Microscopy Facility, University Hospital Aachen, Pauwelstr. 30, 52074 Aachen, Germany;
| | - Mahmoud Sesa
- Institute of Applied Mechanics, RWTH Aachen University, Mies-van-der-Rohe-Str. 1, 52074 Aachen, Germany; (M.S.); (S.R.)
| | - Alicia Fernández-Colino
- Department of Biohybrid & Medical Textiles (BioTex), AME Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Forckenbeckstr. 55, 52074 Aachen, Germany; (C.A.B.); (C.D.); (A.L.); (A.F.-C.)
| | - Stefanie Reese
- Institute of Applied Mechanics, RWTH Aachen University, Mies-van-der-Rohe-Str. 1, 52074 Aachen, Germany; (M.S.); (S.R.)
| | - Stefan Jockenhoevel
- Department of Biohybrid & Medical Textiles (BioTex), AME Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Forckenbeckstr. 55, 52074 Aachen, Germany; (C.A.B.); (C.D.); (A.L.); (A.F.-C.)
- Aachen-Maastricht Institute for Biobased Materials, Maastricht University at Chemelot Campus, Urmonderbaan 22, 6167 Geleen, The Netherlands
| |
Collapse
|
10
|
Li RL, Sun M, Russ JB, Pousse PL, Kossar AP, Gibson I, Paschalides C, Herschman AR, Abyaneh MH, Ferrari G, Bacha E, Waisman H, Vedula V, Kysar JW, Kalfa D. In Vitro Proof of Concept of a First-Generation Growth-Accommodating Heart Valved Conduit for Pediatric Use. Macromol Biosci 2023; 23:e2300011. [PMID: 36905285 PMCID: PMC10363995 DOI: 10.1002/mabi.202300011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 02/27/2023] [Indexed: 03/12/2023]
Abstract
Currently available heart valve prostheses have no growth potential, requiring children with heart valve diseases to endure multiple valve replacement surgeries with compounding risks. This study demonstrates the in vitro proof of concept of a biostable polymeric trileaflet valved conduit designed for surgical implantation and subsequent expansion via transcatheter balloon dilation to accommodate the growth of pediatric patients and delay or avoid repeated open-heart surgeries. The valved conduit is formed via dip molding using a polydimethylsiloxane-based polyurethane, a biocompatible material shown here to be capable of permanent stretching under mechanical loading. The valve leaflets are designed with an increased coaptation area to preserve valve competence at expanded diameters. Four 22 mm diameter valved conduits are tested in vitro for hydrodynamics, balloon dilated to new permanent diameters of 23.26 ± 0.38 mm, and then tested again. Upon further dilation, two valved conduits sustain leaflet tears, while the two surviving devices reach final diameters of 24.38 ± 0.19 mm. After each successful dilation, the valved conduits show increased effective orifice areas and decreased transvalvular pressure differentials while maintaining low regurgitation. These results demonstrate concept feasibility and motivate further development of a polymeric balloon-expandable device to replace valves in children and avoid reoperations.
Collapse
Affiliation(s)
- Richard L Li
- Department of Surgery, Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, 3959 Broadway, CHN-274, New York, NY, 10032, USA
- Department of Mechanical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, 220 Mudd Building, 500 W. 120th Street, New York, NY, 10027, USA
| | - Mingze Sun
- Department of Surgery, Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, 3959 Broadway, CHN-274, New York, NY, 10032, USA
| | - Jonathan B Russ
- Department of Civil Engineering and Engineering Mechanics, Fu Foundation School of Engineering and Applied Science, Columbia University, 610 Mudd Building, 500 W. 120th Street, New York, NY, 10027, USA
| | - Pierre-Louis Pousse
- Department of Surgery, Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, 3959 Broadway, CHN-274, New York, NY, 10032, USA
| | - Alexander P Kossar
- Department of Surgery, Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, 3959 Broadway, CHN-274, New York, NY, 10032, USA
| | - Isabel Gibson
- Department of Surgery, Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, 3959 Broadway, CHN-274, New York, NY, 10032, USA
| | - Costas Paschalides
- Department of Mechanical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, 220 Mudd Building, 500 W. 120th Street, New York, NY, 10027, USA
| | - Abigail R Herschman
- Department of Surgery, Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, 3959 Broadway, CHN-274, New York, NY, 10032, USA
- Department of Mechanical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, 220 Mudd Building, 500 W. 120th Street, New York, NY, 10027, USA
| | - Maryam H Abyaneh
- Department of Surgery, Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, 3959 Broadway, CHN-274, New York, NY, 10032, USA
| | - Giovanni Ferrari
- Department of Surgery, Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, 3959 Broadway, CHN-274, New York, NY, 10032, USA
| | - Emile Bacha
- Department of Surgery, Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, 3959 Broadway, CHN-274, New York, NY, 10032, USA
| | - Haim Waisman
- Department of Civil Engineering and Engineering Mechanics, Fu Foundation School of Engineering and Applied Science, Columbia University, 610 Mudd Building, 500 W. 120th Street, New York, NY, 10027, USA
| | - Vijay Vedula
- Department of Mechanical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, 220 Mudd Building, 500 W. 120th Street, New York, NY, 10027, USA
| | - Jeffrey W Kysar
- Department of Mechanical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, 220 Mudd Building, 500 W. 120th Street, New York, NY, 10027, USA
- Department of Otolaryngology-Head and Neck Surgery, Columbia University Medical Center, 3959 Broadway, 5th Floor, New York, NY, 10032, USA
| | - David Kalfa
- Department of Surgery, Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, 3959 Broadway, CHN-274, New York, NY, 10032, USA
| |
Collapse
|
11
|
Crago M, Winlaw DS, Farajikhah S, Dehghani F, Naficy S. Pediatric pulmonary valve replacements: Clinical challenges and emerging technologies. Bioeng Transl Med 2023; 8:e10501. [PMID: 37476058 PMCID: PMC10354783 DOI: 10.1002/btm2.10501] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 01/17/2023] [Accepted: 01/29/2023] [Indexed: 03/06/2023] Open
Abstract
Congenital heart diseases (CHDs) frequently impact the right ventricular outflow tract, resulting in a significant incidence of pulmonary valve replacement in the pediatric population. While contemporary pediatric pulmonary valve replacements (PPVRs) allow satisfactory patient survival, their biocompatibility and durability remain suboptimal and repeat operations are commonplace, especially for very young patients. This places enormous physical, financial, and psychological burdens on patients and their parents, highlighting an urgent clinical need for better PPVRs. An important reason for the clinical failure of PPVRs is biofouling, which instigates various adverse biological responses such as thrombosis and infection, promoting research into various antifouling chemistries that may find utility in PPVR materials. Another significant contributor is the inevitability of somatic growth in pediatric patients, causing structural discrepancies between the patient and PPVR, stimulating the development of various growth-accommodating heart valve prototypes. This review offers an interdisciplinary perspective on these challenges by exploring clinical experiences, physiological understandings, and bioengineering technologies that may contribute to device development. It thus aims to provide an insight into the design requirements of next-generation PPVRs to advance clinical outcomes and promote patient quality of life.
Collapse
Affiliation(s)
- Matthew Crago
- School of Chemical and Biomolecular EngineeringThe University of SydneySydneyAustralia
| | - David S. Winlaw
- Department of Cardiothoracic SurgeryHeart Institute, Cincinnati Children's HospitalCincinnatiOHUSA
| | - Syamak Farajikhah
- School of Chemical and Biomolecular EngineeringThe University of SydneySydneyAustralia
| | - Fariba Dehghani
- School of Chemical and Biomolecular EngineeringThe University of SydneySydneyAustralia
| | - Sina Naficy
- School of Chemical and Biomolecular EngineeringThe University of SydneySydneyAustralia
| |
Collapse
|
12
|
Yu T, Pu H, Chen X, Kong Q, Chen C, Li G, Jiang Q, Wang Y. A versatile modification strategy for functional non-glutaraldehyde cross-linked bioprosthetic heart valves with enhanced anticoagulant, anticalcification and endothelialization properties. Acta Biomater 2023; 160:45-58. [PMID: 36764592 DOI: 10.1016/j.actbio.2023.02.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 01/31/2023] [Accepted: 02/02/2023] [Indexed: 02/11/2023]
Abstract
Valvular heart disease is a major threat to human health and transcatheter heart valve replacement (THVR) has emerged as the primary treatment option for severe heart valve disease. Bioprosthetic heart valves (BHVs) with superior hemodynamic performance and compressibility have become the first choice for THVR, and more BHVs have been requested for clinical use in recent years. However, several drawbacks remain for the commercial BHVs cross-linked by glutaraldehyde, including calcification, thrombin, poor biocompatibility and difficulty in endothelialization, which would further reduce the BHVs' lifetime. This study developed a dual-functional non-glutaraldehyde crosslinking reagent OX-VI, which can provide BHV materials with reactive double bonds (CC) for further bio-function modification in addition to the crosslinking function. BHV material PBAF@OX-PP was developed from OX-VI treated porcine pericardium (PP) after the polymerization with 4-vinylbenzene boronic acid and the subsequent modification of poly (vinyl alcohol) and fucoidan. Based on the functional anti-coagulation and endothelialization strategy and dual-functional crosslinking reagent, PBAF@OX-PP has better anti-coagulation and anti-calcification properties, higher biocompatibility, and improved endothelial cells proliferation when compared to Glut-treated PP, as well as the satisfactory mechanical properties and enhanced resistance effect to enzymatic degradation, making it a promising candidate in the clinical application of BHVs. STATEMENT OF SIGNIFICANCE: Transcatheter heart valve replacement (THVR) has become the main solution for severe valvular heart disease. However, bioprosthetic heart valves (BHVs) used in THVR exhibit fatal drawbacks such as calcification, thrombin and difficulty for endothelialization, which are due to the glutaraldehyde crosslinking, resulting in a limited lifetime to 10-15 years. A new non-glutaraldehyde cross-linker OX-VI has been designed, which can not only show great crosslinking ability but also offer the BHVs with reactive double bonds (CC) for further bio-function modification. Based on the dual-functional crosslinking reagent OX-VI, a versatile modification strategy was developed and the BHV material (PBAF@OX-PP) has been developed and shows significantly enhanced anticoagulant, anti-calcification and endothelialization properties, making it a promising candidate in the clinical application of BHVs.
Collapse
Affiliation(s)
- Tao Yu
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, 29 Wangjiang Road, Chengdu 610064, China
| | - Hongxia Pu
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, 29 Wangjiang Road, Chengdu 610064, China
| | - Xiaotong Chen
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, 29 Wangjiang Road, Chengdu 610064, China
| | - Qunshou Kong
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, 29 Wangjiang Road, Chengdu 610064, China
| | - Chong Chen
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, 29 Wangjiang Road, Chengdu 610064, China
| | - Gaocan Li
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, 29 Wangjiang Road, Chengdu 610064, China.
| | - Qing Jiang
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, 29 Wangjiang Road, Chengdu 610064, China.
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, 29 Wangjiang Road, Chengdu 610064, China
| |
Collapse
|
13
|
Hunckler MD, Levine AD. Navigating ethical challenges in the development and translation of biomaterials research. Front Bioeng Biotechnol 2022; 10:949280. [PMID: 36204464 PMCID: PMC9530811 DOI: 10.3389/fbioe.2022.949280] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Accepted: 08/22/2022] [Indexed: 11/24/2022] Open
Abstract
Biomaterials--from implanted iron teeth in the second century to intraocular lenses, artificial joints, and stents today--have long been used clinically. Today, biomaterials researchers and biomedical engineers are pushing beyond these inert synthetic alternatives and incorporating complex multifunctional materials to control biological interactions and direct physiological processes. These advances are leading to novel strategies for targeted drug delivery, drug screening, diagnostics and imaging, gene therapy, tissue regeneration, and cell transplantation. While the field has survived ethical transgressions in the past, the rapidly expanding scope of biomaterials science, combined with the accelerating clinical translation of this diverse field calls for urgent attention to the complex and challenging ethical dilemmas these advances pose. This perspective responds to this call, examining the intersection of research ethics -- the sets of rules, principles and norms guiding responsible scientific inquiry -- and ongoing advances in biomaterials. While acknowledging the inherent tensions between certain ethical norms and the pressures of the modern scientific and engineering enterprise, we argue that the biomaterials community needs to proactively address ethical issues in the field by, for example, updating or adding specificity to codes of ethics, modifying training programs to highlight the importance of ethical research practices, and partnering with funding agencies and journals to adopt policies prioritizing the ethical conduct of biomaterials research. Together these actions can strengthen and support biomaterials as its advances are increasingly commercialized and impacting the health care system.
Collapse
Affiliation(s)
- Michael D. Hunckler
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia, United States
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia, United States
| | - Aaron D. Levine
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia, United States
- School of Public Policy, Georgia Institute of Technology, Atlanta, Georgia, United States
- *Correspondence: Aaron D. Levine,
| |
Collapse
|
14
|
Sutherland DW, McEleney A, de Almeida M, Kajimoto M, Ventura G, Isenberg BC, Portman MA, Stapleton SE, Williams C. Characterization of main pulmonary artery and valve annulus region of piglets using echocardiography, uniaxial tensile testing, and a novel non-destructive technique. Front Cardiovasc Med 2022; 9:884116. [PMID: 36093160 PMCID: PMC9459108 DOI: 10.3389/fcvm.2022.884116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 08/08/2022] [Indexed: 11/23/2022] Open
Abstract
Characterization of cardiovascular tissue geometry and mechanical properties of large animal models is essential when developing cardiovascular devices such as heart valve replacements. These datasets are especially critical when designing devices for pediatric patient populations, as there is often limited data for guidance. Here, we present a previously unavailable dataset capturing anatomical measurements and mechanical properties of juvenile Yorkshire (YO) and Yucatan (YU) porcine main pulmonary artery (PA) and pulmonary valve (PV) tissue regions that will inform pediatric heart valve design requirements for preclinical animal studies. In addition, we developed a novel radial balloon catheter-based method to measure tissue stiffness and validated it against a traditional uniaxial tensile testing method. YU piglets, which were significantly lower weight than YO counterparts despite similar age, had smaller PA and PV diameters (7.6-9.9 mm vs. 10.1-12.8 mm). Young's modulus (stiffness) was measured for the PA and the PV region using both the radial and uniaxial testing methods. There was no significant difference between the two breeds for Young's modulus measured in the elastic (YU PA 84.7 ± 37.3 kPa, YO PA 79.3 ± 15.7 kPa) and fibrous regimes (YU PA 308.6 ± 59.4 kPa, YO PA 355.7 ± 68.9 kPa) of the stress-strain curves. The two testing techniques also produced similar stiffness measurements for the PA and PV region, although PV data showed greater variation between techniques. Overall, YU and YO piglets had similar PA and PV diameters and tissue stiffness to previously reported infant pediatric patients. These results provide a previously unavailable age-specific juvenile porcine tissue geometry and stiffness dataset critical to the development of pediatric cardiovascular prostheses. Additionally, the data demonstrates the efficacy of a novel balloon catheter-based technique that could be adapted to non-destructively measure tissue stiffness in situ.
Collapse
Affiliation(s)
- David W. Sutherland
- Bioengineering Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, United States
| | - Aisling McEleney
- Bioengineering Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, United States
| | - Matheus de Almeida
- Bioengineering Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, United States
| | - Masaki Kajimoto
- Seattle Children’s Research Institute, Seattle Children’s Hospital, Seattle, WA, United States
| | - Giselle Ventura
- Bioengineering Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, United States
| | - Brett C. Isenberg
- Bioengineering Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, United States
| | - Michael A. Portman
- Seattle Children’s Research Institute, Seattle Children’s Hospital, Seattle, WA, United States
| | - Scott E. Stapleton
- Department of Mechanical Engineering, University of Massachusetts, Lowell, MA, United States
| | - Corin Williams
- Bioengineering Division, The Charles Stark Draper Laboratory, Inc., Cambridge, MA, United States
| |
Collapse
|
15
|
Kalfa D. Novel Valve Choices for Pulmonary Valve Replacement. Semin Thorac Cardiovasc Surg 2022; 35:523-529. [PMID: 35032644 DOI: 10.1053/j.semtcvs.2021.11.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 11/12/2021] [Accepted: 11/15/2021] [Indexed: 11/11/2022]
Affiliation(s)
- David Kalfa
- Department of Surgery, Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital and Cardiac Surgery, Morgan Stanley Children Hospital -New York Presbyterian, Columbia University College of Physicians and Surgeons, New York, New York.
| |
Collapse
|
16
|
The isoflavone puerarin exerts anti-tumor activity in pancreatic ductal adenocarcinoma by suppressing mTOR-mediated glucose metabolism. Aging (Albany NY) 2021; 13:25089-25105. [PMID: 34863080 PMCID: PMC8714170 DOI: 10.18632/aging.203725] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Accepted: 11/22/2021] [Indexed: 12/21/2022]
Abstract
Puerarin (8-(β-D-glucopyranosyl)-4′, 7-dihydroxyisoflavone), a natural flavonoid compound isolated from the traditional Chinese herb Radix puerariae, have been demonstrated has potential anti-tumor effects via induction of apoptosis and inhibition of proliferation. However, the effect and molecular mechanism of puerarin in pancreatic ductal adenocarcinoma (PDAC) remains unknown. In this study, the tumor-suppressive effects of puerarin were determined by both in-vitro and in-vivo assays. The effects of puerarin on the proliferation, apoptosis, migration and invasion of pancreatic cancer cells (PCCs), and tumor growth and metastasis in PDAC xenograft mouse model were performed. Puerarin treatment significantly repressed PCC proliferation. Puerarin induced the mitochondrial-dependent apoptosis of PCCs by causing a Bcl-2/Bax imbalance. Moreover, puerarin inhibited PCC migration and invasion by antagonizing epithelial-mesenchymal transition (EMT). In nude mouse model, PDAC growth and metastasis were reduced by puerarin administration. Mechanistically, puerarin exerted its therapeutic effects on PDAC by suppressing Akt/mTOR signaling. Importantly, puerarin bound to the kinase domain of mTOR protein, affecting the activity of the surrounding amino acid residues associated with the binding of the ATP-Mg2+ complex. Further studies showed that the inhibitory effects of puerarin on PCCs were abolished by a mTOR activator, indicating a crucial role of mTOR in anti-tumor effects of puerarin in PDAC. As a result, puerarin hindered glucose uptake and metabolism by downregulating the oxygen consumption rate (OCR) and the extracellular acidification rate (ECAR) dependent upon HIF-1α and glucose transporter GLUT1. Therefore, these findings indicated that puerarin has therapeutic potential for the treatment of PDAC by suppressing glucose uptake and metabolism via Akt/mTOR activity.
Collapse
|
17
|
Immuno-regenerative biomaterials for in situ cardiovascular tissue engineering - Do patient characteristics warrant precision engineering? Adv Drug Deliv Rev 2021; 178:113960. [PMID: 34481036 DOI: 10.1016/j.addr.2021.113960] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 08/20/2021] [Accepted: 08/30/2021] [Indexed: 02/07/2023]
Abstract
In situ tissue engineering using bioresorbable material implants - or scaffolds - that harness the patient's immune response while guiding neotissue formation at the site of implantation is emerging as a novel therapy to regenerate human tissues. For the cardiovascular system, the use of such implants, like blood vessels and heart valves, is gradually entering the stage of clinical translation. This opens up the question if and to what extent patient characteristics influence tissue outcomes, necessitating the precision engineering of scaffolds to guide patient-specific neo-tissue formation. Because of the current scarcity of human in vivo data, herein we review and evaluate in vitro and preclinical investigations to predict the potential role of patient-specific parameters like sex, age, ethnicity, hemodynamics, and a multifactorial disease profile, with special emphasis on their contribution to the inflammation-driven processes of in situ tissue engineering. We conclude that patient-specific conditions have a strong impact on key aspects of in situ cardiovascular tissue engineering, including inflammation, hemodynamic conditions, scaffold resorption, and tissue remodeling capacity, suggesting that a tailored approach may be required to engineer immuno-regenerative biomaterials for safe and predictive clinical applicability.
Collapse
|
18
|
Russ JB, Li RL, Herschman AR, Waisman H, Vedula V, Kysar JW, Kalfa D. Design optimization of a cardiovascular stent with application to a balloon expandable prosthetic heart valve. MATERIALS & DESIGN 2021; 209:109977. [PMID: 34366534 PMCID: PMC8336925 DOI: 10.1016/j.matdes.2021.109977] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
A cardiovascular stent design optimization method is proposed with application to a pediatric balloon-expandable prosthetic heart valve. The prosthetic valved conduit may be expanded to a larger permanent diameter in vivo via subsequent transcatheter balloon dilation procedures. While multiple expandable prosthetic heart valves are currently at different stages of development, this work is focused on one particular design in which a stent is situated inside of an expandable polymeric valved conduit. Since the valve and conduit must be joined with a robust manufacturing technique, a polymeric glue layer is inserted between the two, which results in radial retraction of the valved region after expansion. Design of an appropriate stent is proposed to counteract this phenomenon and maintain the desired permanent diameter throughout the device after a single non-compliant balloon dilation procedure. The finite element method is used to compute performance metrics related to the permanent expansion diameter and required radial force. Additionally, failure due not only to high cycle fatigue but also due to ductile fracture is incorporated into the design study through the use of an existing ductile fracture criterion for metals. Surrogate models are constructed with the results of the high fidelity simulations and are subsequently used to numerically obtain a set of Pareto-optimal stent designs. Finally, a single design is identified by optimizing a normalized aggregate objective function with equal weighting of all design objectives.
Collapse
Affiliation(s)
- Jonathan B. Russ
- Columbia University, Department of Civil Engineering and Engineering Mechanics, New York, NY, USA
| | - Richard L. Li
- Columbia University, Department of Mechanical Engineering, New York, NY, USA
- Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children’s Hospital, Columbia University Medical Center, New York, NY, USA
| | - Abigail R. Herschman
- Columbia University, Department of Mechanical Engineering, New York, NY, USA
- Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children’s Hospital, Columbia University Medical Center, New York, NY, USA
| | - Haim Waisman
- Columbia University, Department of Civil Engineering and Engineering Mechanics, New York, NY, USA
| | - Vijay Vedula
- Columbia University, Department of Mechanical Engineering, New York, NY, USA
| | - Jeffrey W. Kysar
- Columbia University, Department of Mechanical Engineering, New York, NY, USA
- Department of Otolaryngology Head and Neck Surgery, Columbia University Medical Center, New York, NY, USA
| | - David Kalfa
- Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children’s Hospital, Columbia University Medical Center, New York, NY, USA
| |
Collapse
|
19
|
Bui HT, Khair N, Yeats B, Gooden S, James SP, Dasi LP. Transcatheter Heart Valves: A Biomaterials Perspective. Adv Healthc Mater 2021; 10:e2100115. [PMID: 34038627 DOI: 10.1002/adhm.202100115] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 04/23/2021] [Indexed: 11/11/2022]
Abstract
Heart valve disease is prevalent throughout the world, and the number of heart valve replacements is expected to increase rapidly in the coming years. Transcatheter heart valve replacement (THVR) provides a safe and minimally invasive means for heart valve replacement in high-risk patients. The latest clinical data demonstrates that THVR is a practical solution for low-risk patients. Despite these promising results, there is no long-term (>20 years) durability data on transcatheter heart valves (THVs), raising concerns about material degeneration and long-term performance. This review presents a detailed account of the materials development for THVRs. It provides a brief overview of THVR, the native valve properties, the criteria for an ideal THV, and how these devices are tested. A comprehensive review of materials and their applications in THVR, including how these materials are fabricated, prepared, and assembled into THVs is presented, followed by a discussion of current and future THVR biomaterial trends. The field of THVR is proliferating, and this review serves as a guide for understanding the development of THVs from a materials science and engineering perspective.
Collapse
Affiliation(s)
- Hieu T. Bui
- Department of Biomedical Engineering Georgia Institute of Technology 387 Technology Cir NW Atlanta GA 30313 USA
| | - Nipa Khair
- School of Advanced Materials Discovery Colorado State University 700 Meridian Ave Fort Collins CO 80523 USA
| | - Breandan Yeats
- Department of Biomedical Engineering Georgia Institute of Technology 387 Technology Cir NW Atlanta GA 30313 USA
| | - Shelley Gooden
- Department of Biomedical Engineering Georgia Institute of Technology 387 Technology Cir NW Atlanta GA 30313 USA
| | - Susan P. James
- School of Advanced Materials Discovery Colorado State University 700 Meridian Ave Fort Collins CO 80523 USA
| | - Lakshmi Prasad Dasi
- Department of Biomedical Engineering Georgia Institute of Technology 387 Technology Cir NW Atlanta GA 30313 USA
| |
Collapse
|
20
|
Biodegradable polymeric occluder for closure of atrial septal defect with interventional treatment of cardiovascular disease. Biomaterials 2021; 274:120851. [PMID: 33965798 DOI: 10.1016/j.biomaterials.2021.120851] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2021] [Accepted: 04/22/2021] [Indexed: 02/07/2023]
Abstract
The next-generation closure device for interventional treatment of congenital heart disease is regarded to be biodegradable, yet the corresponding biomaterial technique is still challenging. Herein, we report the first fully biodegradable atrial septal defect (ASD) occluder finally coming into clinical use, which is made of biodegradable poly(l-lactic acid) (PLLA). We characterized the physico-chemical properties of PLLA fibers as well as the raw polymer and the operability of the as-fabricated occluders. Cell behaviors on material were observed, and in vivo fiber degradation and inflammatory responses were examined. ASD models in piglets were created, and 44 PLLA ASD occluders were implanted via catheter successfully. After 36 months, the PLLA ASD occluders almost degraded without any complications. The mechanical properties and thickness between newborn and normal atrial septum showed no significant difference. We further accomplished the first clinical implantation of the PLLA ASD occluder in a four-year boy, and the two-year follow-up up to date preliminarily indicated safety and feasibility of such new-generation fully biodegradable occluder made of synthetic polymers.
Collapse
|
21
|
Azakie A, Carney JP, Lahti MT, Bianco RW, Doyle MJ, Kalra R, Martin CM. Porcine Model of the Arterial Switch Operation: Implications for Unique Strategies in the Management of Hypoplastic Left Ventricles. Pediatr Cardiol 2021; 42:501-509. [PMID: 33252768 PMCID: PMC7990748 DOI: 10.1007/s00246-020-02507-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Accepted: 11/17/2020] [Indexed: 11/26/2022]
Abstract
There are no reports on the performance of the arterial switch operation (ASO) in a normal heart with normally related great vessels. The objective of this study was to determine whether the ASO could be performed in a healthy animal model. Cardiopulmonary bypass (CPB) and coronary translocation techniques were used to perform ASO in neonatal piglets or a staged ASO with prior main pulmonary artery (PA) banding. Primary ASO was performed in four neonatal piglets. Coronary translocation was effective with angiograms confirming patency. Piglets could not be weaned from CPB due to right ventricle (RV) dysfunction. To improve RV function for the ASO, nine piglets had PA banding. All survived the procedure. Post-banding RV pressure increased from a mean of 20.3 ± 2.2 mmHg to 36.5 ± 7.3 mmHg (p = 0.007). At 58 ± 1 days post-banding, piglets underwent cardiac MRIs revealing RV hypertrophy, and RV pressure overload with mildly reduced RV function. Catheterization confirmed RV systolic pressures of 84.0 ± 6.7 mmHg with LV systolic pressure 83.3 ± 6.7 mmHg (p = 0.43). The remaining five PA banded piglets underwent ASO at 51 ± 0 days post-banding. Three of five were weaned from bypass with patent coronary arteries and adequate RV function. We were able to successfully perform an arterial switch with documented patent coronary arteries on standard anatomy great vessels in a healthy animal model. To our knowledge this is the first time this procedure has been successfully performed. The model may have implications for studying the failing systemic RV, and may support a novel approach for management of borderline, pulsatile left ventricles.
Collapse
Affiliation(s)
- Anthony Azakie
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota Medical School, Minneapolis, MN 55455 USA
| | - John P. Carney
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota Medical School, Minneapolis, MN 55455 USA
| | - Matthew T. Lahti
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota Medical School, Minneapolis, MN 55455 USA
| | - Richard W. Bianco
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota Medical School, Minneapolis, MN 55455 USA
| | - Michelle J. Doyle
- Cardiovascular Division, Department of Medicine, University of Minnesota Medical School, Minneapolis, MN USA
| | - Rajat Kalra
- Cardiovascular Division, Department of Medicine, University of Minnesota Medical School, Minneapolis, MN USA
| | - Cindy M. Martin
- Cardiovascular Division, Department of Medicine, University of Minnesota Medical School, Minneapolis, MN USA
| |
Collapse
|
22
|
Taghizadeh B, Ghavami L, Derakhshankhah H, Zangene E, Razmi M, Jaymand M, Zarrintaj P, Zarghami N, Jaafari MR, Moallem Shahri M, Moghaddasian A, Tayebi L, Izadi Z. Biomaterials in Valvular Heart Diseases. Front Bioeng Biotechnol 2020; 8:529244. [PMID: 33425862 PMCID: PMC7793990 DOI: 10.3389/fbioe.2020.529244] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Accepted: 11/16/2020] [Indexed: 01/07/2023] Open
Abstract
Valvular heart disease (VHD) occurs as the result of valvular malfunction, which can greatly reduce patient's quality of life and if left untreated may lead to death. Different treatment regiments are available for management of this defect, which can be helpful in reducing the symptoms. The global commitment to reduce VHD-related mortality rates has enhanced the need for new therapeutic approaches. During the past decade, development of innovative pharmacological and surgical approaches have dramatically improved the quality of life for VHD patients, yet the search for low cost, more effective, and less invasive approaches is ongoing. The gold standard approach for VHD management is to replace or repair the injured valvular tissue with natural or synthetic biomaterials. Application of these biomaterials for cardiac valve regeneration and repair holds a great promise for treatment of this type of heart disease. The focus of the present review is the current use of different types of biomaterials in treatment of valvular heart diseases.
Collapse
Affiliation(s)
- Bita Taghizadeh
- Department of Medical Biotechnology, School of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Laleh Ghavami
- Laboratory of Biophysics and Molecular Biology, Department of Biophysics, Institute of Biochemistry and Biophysics, University of Tehran, Tehran, Iran
| | - Hossein Derakhshankhah
- Pharmaceutical Sciences Research Center, Health Institute, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Ehsan Zangene
- Department of Bioinformatics, Institute of Biochemistry and Biophysics, University of Tehran, Tehran, Iran
| | - Mahdieh Razmi
- Department of Biochemistry, Institute of Biochemistry and Biophysics, University of Tehran, Tehran, Iran
| | - Mehdi Jaymand
- Nano Drug Delivery Research Center, Health Technology Institute, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Payam Zarrintaj
- Polymer Engineering Department, Faculty of Engineering, Urmia University, Urmia, Iran
| | - Nosratollah Zarghami
- Department of Medical Biotechnology, School of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mahmoud Reza Jaafari
- Biotechnology Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
- Department of Pharmaceutical Nanotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Matin Moallem Shahri
- Cardiology Department, Taleghani Trauma Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | | | - Lobat Tayebi
- Marquette University School of Dentistry, Milwaukee, WI, United States
| | - Zhila Izadi
- Pharmaceutical Sciences Research Center, Health Institute, Kermanshah University of Medical Sciences, Kermanshah, Iran
- Department of Regenerative Medicine, Cell Science Research Center, Academic Center for Education, Culture and Research (ACECR), Royan Institute for Stem Cell Biology and Technology, Tehran, Iran
| |
Collapse
|
23
|
Commentary: In pursuit of a pediatric heart valve that can grow with the child. JTCVS Tech 2020; 5:87-88. [PMID: 34318117 PMCID: PMC8300003 DOI: 10.1016/j.xjtc.2020.11.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2020] [Revised: 10/31/2020] [Accepted: 11/06/2020] [Indexed: 11/23/2022] Open
|
24
|
Fang Y, Meng L, Prominski A, Schaumann EN, Seebald M, Tian B. Recent advances in bioelectronics chemistry. Chem Soc Rev 2020. [PMID: 32672777 DOI: 10.1039/d1030cs00333f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/15/2023]
Abstract
Research in bioelectronics is highly interdisciplinary, with many new developments being based on techniques from across the physical and life sciences. Advances in our understanding of the fundamental chemistry underlying the materials used in bioelectronic applications have been a crucial component of many recent discoveries. In this review, we highlight ways in which a chemistry-oriented perspective may facilitate novel and deep insights into both the fundamental scientific understanding and the design of materials, which can in turn tune the functionality and biocompatibility of bioelectronic devices. We provide an in-depth examination of several developments in the field, organized by the chemical properties of the materials. We conclude by surveying how some of the latest major topics of chemical research may be further integrated with bioelectronics.
Collapse
Affiliation(s)
- Yin Fang
- The James Franck Institute, University of Chicago, Chicago, IL 60637, USA.
| | | | | | | | | | | |
Collapse
|
25
|
Fang Y, Meng L, Prominski A, Schaumann E, Seebald M, Tian B. Recent advances in bioelectronics chemistry. Chem Soc Rev 2020; 49:7978-8035. [PMID: 32672777 PMCID: PMC7674226 DOI: 10.1039/d0cs00333f] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Research in bioelectronics is highly interdisciplinary, with many new developments being based on techniques from across the physical and life sciences. Advances in our understanding of the fundamental chemistry underlying the materials used in bioelectronic applications have been a crucial component of many recent discoveries. In this review, we highlight ways in which a chemistry-oriented perspective may facilitate novel and deep insights into both the fundamental scientific understanding and the design of materials, which can in turn tune the functionality and biocompatibility of bioelectronic devices. We provide an in-depth examination of several developments in the field, organized by the chemical properties of the materials. We conclude by surveying how some of the latest major topics of chemical research may be further integrated with bioelectronics.
Collapse
Affiliation(s)
- Yin Fang
- The James Franck Institute, University of Chicago, Chicago, IL 60637, USA
| | - Lingyuan Meng
- Pritzker School of Molecular Engineering, University of Chicago, Chicago, IL 60637, USA
| | | | - Erik Schaumann
- Department of Chemistry, University of Chicago, Chicago, IL 60637, USA
| | - Matthew Seebald
- Department of Chemistry, University of Chicago, Chicago, IL 60637, USA
| | - Bozhi Tian
- The James Franck Institute, University of Chicago, Chicago, IL 60637, USA
- Department of Chemistry, University of Chicago, Chicago, IL 60637, USA
- The Institute for Biophysical Dynamics, University of Chicago, Chicago, IL 60637, USA
| |
Collapse
|
26
|
Preventive Effect of Albumin Nano TPA Gene Plasmid Ultrasound Microbubble Carrier System on Thrombosis after Cardiac Valve Replacement. J CHEM-NY 2020. [DOI: 10.1155/2020/9041821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
After cardiac valve replacement, most patients will have different degrees of thrombosis, different parts of the thrombus, and even more frequent occurrence of postoperative thrombosis; therefore, the prevention of postoperative thrombosis is particularly important. The purpose of this study was to investigate the preventive effect of albumin nano tPA gene plasmid ultrasound microbubble carrier system on thrombosis, especially in cardiac valve. The experimental control method was used. Firstly, 11 dogs meeting the experimental requirements were selected. Secondly, the data of albumin nanoparticles and microbubbles were analyzed. The average size of albumin particles was 132.0 nm, the average size of microbubbles was 3.1 ± 1.6 μm, and the zeta potential was 13.70 ± 1.95 MV. The concentration of microbubbles was 4.2 ± 1.3 × 10/ml. Finally, 11 dogs were divided into two groups. The experimental group was treated with albumin nanoparticles ultrasound microbubble, and the others were the control group. It was found that the levels of tPA and D-dimer in the experimental group were significantly increased and maintained at a high level at 1 week after operation, and the prothrombin time was detected and the international normalized ratio was calculated at the same time. No significant changes were found in the experimental group.
Collapse
|
27
|
Fernández-Colino A, Jockenhoevel S. Advances in Engineering Venous Valves: The Pursuit of a Definite Solution for Chronic Venous Disease. TISSUE ENGINEERING PART B-REVIEWS 2020; 27:253-265. [PMID: 32967586 DOI: 10.1089/ten.teb.2020.0131] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Native venous valves enable proper return of blood to the heart. Under pathological conditions (e.g., chronic venous insufficiency), venous valves malfunction and fail to prevent backward flow. Clinically, this can result in painful swelling, varicose veins, edema, and skin ulcerations leading to a chronic wound situation. Surgical correction of venous valves has proven to drastically reduce these symptoms. However, the absence of intact leaflets in many patients limits the applicability of this strategy. In this context, the development of venous valve replacements represents an appealing approach. Despite acceptable results in animal models, no venous valve has succeeded in clinical trials, and so far no single prosthetic venous valve is commercially available. This calls for advanced materials and fabrication approaches to develop clinically relevant venous valves able to restore natural flow conditions in the venous circulation. In this study, we critically discuss the approaches attempted in the last years, and we highlight the potential of tissue engineering to offer new avenues for valve fabrication. Impact statement Venous valves prosthesis offer the potential to restore normal venous flow, and to improve the prospect of patients that suffer from chronic venous disease. Current venous valve replacements are associated with poor outcomes. A deeper understanding of the approaches attempted so far is essential to establish the next steps toward valve development, and importantly, tissue engineering constitutes a unique toolbox to advance in this quest.
Collapse
Affiliation(s)
- Alicia Fernández-Colino
- Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Stefan Jockenhoevel
- Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.,AMIBM-Aachen-Maastricht-Institute for Biobased Materials, Maastricht University, Geleen, Netherlands
| |
Collapse
|
28
|
Kalfa D. Commentary: Innovation in the clinical care of congenital heart defects: Surgeons can and need to weigh in. J Thorac Cardiovasc Surg 2020; 162:972-973. [PMID: 33618864 DOI: 10.1016/j.jtcvs.2020.09.050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 09/11/2020] [Accepted: 09/14/2020] [Indexed: 11/26/2022]
Affiliation(s)
- David Kalfa
- Section of Pediatric and Congenital Cardiac Surgery, Division of Cardiac, Thoracic and Vascular Surgery, New-York Presbyterian-Morgan Stanley Children's Hospital, Columbia University Medical Center, New York, NY.
| |
Collapse
|
29
|
Hu C, Luo R, Wang Y. Heart Valves Cross-Linked with Erythrocyte Membrane Drug-Loaded Nanoparticles as a Biomimetic Strategy for Anti-coagulation, Anti-inflammation, Anti-calcification, and Endothelialization. ACS APPLIED MATERIALS & INTERFACES 2020; 12:41113-41126. [PMID: 32833422 DOI: 10.1021/acsami.0c12688] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In recent years, valvular heart disease has become a serious disease threatening human life and is a major cause of death worldwide. However, the glutaraldehyde (GLU)-treated biological heart valves (BHVs) fail to meet all requirements of clinical application due to disadvantages such as valve thrombus, cytotoxicity, endothelialization difficulty, immune response, and calcification. Encouragingly, there are a large number of carboxyls as well as a few amino groups on the surface of GLU-treated BHVs that can be modified to enhance biocompatibility. Inspired by natural biological systems, we report a novel approach in which the heart valve was cross-linked with erythrocyte membrane biomimetic drug-loaded nanoparticles. Such modified heart valves not only preserved the structural integrity, stability, and mechanical properties of the GLU-treated BHVs but also greatly improved anti-coagulation, anti-inflammation, anti-calcification, and endothelialization. The in vitro results demonstrated that the modified heart valves had long-term anti-coagulation properties and enhanced endothelialization processes. The modified heart valves also showed good biocompatibility, including blood and cell biocompatibility. Most importantly, the modified heart valves reduced the TNF-α levels and increased IL-10 compared to GLU-treated BHVs. In vivo animal experiments also confirmed that the modified heart valves had an ultrastrong resistance to calcification after implantation in rats for 120 days. The mechanism of anti-calcification in vivo was mainly due to the controlled release of anti-inflammatory drugs that reduced the inflammatory response after valve implantation. In summary, this therapeutic approach based on BHVs cross-linking with erythrocyte membrane biomimetic nanoparticles sparks a novel design for valvular heart disease therapy.
Collapse
Affiliation(s)
- Cheng Hu
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, Sichuan 610064, People's Republic of China
| | - Rifang Luo
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, Sichuan 610064, People's Republic of China
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, Sichuan 610064, People's Republic of China
| |
Collapse
|
30
|
Commentary: In pursuit of the perfect pulmonary valve…. J Thorac Cardiovasc Surg 2020; 161:365-367. [PMID: 32921441 DOI: 10.1016/j.jtcvs.2020.08.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 08/12/2020] [Accepted: 08/13/2020] [Indexed: 11/21/2022]
|
31
|
Azakie A, Carney JP, Lahti MT, Moklyak Y, Bianco RW. Anisotropic Polytetrafluoroethylene Cardiovascular Conduits Spontaneously Expand in a Growing Lamb Model. J INVEST SURG 2020; 34:1348-1354. [PMID: 32791879 DOI: 10.1080/08941939.2020.1805056] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND Insertion of conduits from the right ventricle (RV) to the pulmonary artery (PA) is a commonly used technique for repair of congenital heart defects. The vast majority of infants and children will require reoperation and/or re-intervention to replace the conduit. Some children may require multiple reoperations, with the risk of death and morbidity increasing significantly with each subsequent operation. We evaluated the feasibility and performance of a relatively novel anisotropic conduit for cardiovascular repair in the growing lamb model. MATERIALS AND METHODS Lambs were allocated into a control (n = 3) or test (n = 4, anisotropic) conduit group. Control conventional polytetrafluoroethylene (PTFE) conduits or test anisotropic expanded PTFE (ePTFE) based test conduits measuring 10-11 mm in diameter were sewn as interpositional grafts in the main pulmonary artery (MPA) and followed up to 6 months. Clinical and echocardiographic evaluations were performed monthly with hemodynamic and angiographic assessment at 3 and 6 months. RESULTS Control conduits did not expand, all 3 animals developed one or more adverse events including tachypnea, ascites, inappetence, lethargy, and mortality due to severe right heart failure and significantly higher peak trans-conduit gradients (48.5 ± 5.1 p = 0.02). The test conduits spontaneously expanded up to 14.8 ± 0.8 mm in diameter, no adverse events were observed in any animals and trans-conduit gradients were significantly lower (27.0 ± 8.3, p = 0.02). CONCLUSIONS Anisotropic ePTFE conduits can be safely implanted in growing lambs with stable hemodynamics. This spontaneously expanding anisotropic conduit may represent a novel approach to congenital heart repairs that would avoid the need for reoperation or multiple operations.
Collapse
Affiliation(s)
- Anthony Azakie
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota, Minneapolis, Minnesota, USA.,Division of Pediatric Cardiac Surgery, Peyton Manning Children's Hospital, Ascension St. Vincent, Indianapolis, Indiana, USA
| | - John P Carney
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota, Minneapolis, Minnesota, USA
| | - Matthew T Lahti
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota, Minneapolis, Minnesota, USA
| | - Yuriy Moklyak
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota, Minneapolis, Minnesota, USA
| | - Richard W Bianco
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
32
|
Azakie A, Carney JP, Lahti MT, Seiberlich MK, Hiremath G, Moklyak Y, Bianco RW. Feasibility Study of Catheter-Based Interventions for Anisotropic Expanded Polytetrafluoroethylene Cardiovascular Conduits in a Growing Lamb Model. J INVEST SURG 2020; 34:1231-1237. [PMID: 32684061 DOI: 10.1080/08941939.2020.1795324] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
BACKGROUND Cardiovascular repair in children often requires implant of conduits which do not have growth potential and will require reoperation. In the current study we sought to determine the feasibility of catheter-based interventions of anisotropic conduits inserted as interposition grafts in the main pulmonary artery (MPA) of growing lambs. METHODS Lambs underwent interpositional implant of either an anisotropic expanded polytetrafluoroethylene (ePTFE) (Test) conduit or conventional PTFE (Control) conduit. In the postoperative period, lambs were anesthetized and underwent catheter-based interventions consisting of hemodynamic and angiographic data collection, balloon dilation and/or stenting of the conduit at 3, 6 or 9 month postoperative time point. RESULTS At 3 months, control lambs showed significant increases in right ventricular pressures and trans-conduit gradients in comparison to test lambs. Test conduit diameters were significantly larger compared to controls due to spontaneous radial expansion of the anisotropic conduit. Balloon dilation of test conduits at 3 and 6 months showed a reduction in RV pressure and statistically significant improvement in the RV outflow tract gradient as well as significant increase in graft diameter, compared to both control and pre-dilation conditions. Furthermore, the test conduit diameter increased significantly compared to the pre-balloon and control conditions at each time point. Necropsy of test conduits showed no evidence of tears, perforations, or clot and smooth interiors with well-healed anastomoses. CONCLUSIONS Anisotropic conduits implanted as interposition grafts in the MPA show spontaneous expansion, and can safely and effectively undergo catheter-based interventions, with significant increases in graft diameter occurring after balloon dilation.
Collapse
Affiliation(s)
- Anthony Azakie
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota, Minneapolis, MN, USA.,Division of Pediatric Cardiac Surgery, Peyton Manning Children's Hospital, Ascension St. Vincent, Indianapolis, IN, USA
| | - John P Carney
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota, Minneapolis, MN, USA
| | - Matthew T Lahti
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota, Minneapolis, MN, USA
| | - Melissa K Seiberlich
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota, Minneapolis, MN, USA
| | - Gurumurthy Hiremath
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota, Minneapolis, MN, USA.,Department of Pediatrics, University of Minnesota, Minneapolis, MN, USA
| | - Yuriy Moklyak
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota, Minneapolis, MN, USA
| | - Richard W Bianco
- Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|