1
|
Beausoleil C, Comstock SL, Werner D, Li L, Eby JM, Zook EC. Antimicrobial persistence of two alcoholic preoperative skin preparation solutions. J Hosp Infect 2022; 129:8-16. [PMID: 36049573 DOI: 10.1016/j.jhin.2022.08.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 08/08/2022] [Accepted: 08/17/2022] [Indexed: 11/15/2022]
Abstract
BACKGROUND Normal skin flora and suboptimal skin antisepsis are the primary drivers of healthcare-associated infections (HAIs). Antimicrobial persistence of preoperative skin preparation is necessary to limit microorganisms on the skin and help minimize their entry into an incision or device-insertion site after application. AIM To assess the antimicrobial persistence of two preoperative skin preparation solutions. METHODS A randomized, single-centre, partially blinded, clinical study was conducted in 103 healthy volunteers to evaluate the persistent antimicrobial properties of BD ChloraPrep™ (2% w/v chlorhexidine gluconate [CHG] + 70% v/v isopropyl alcohol [IPA]) and BD PurPrep™ (8.3% w/w povidone-iodine [PVP-I] + 72.5% w/w IPA) skin preparations out to 7 days and 96 hours, respectively, on abdomen and groin testing sites. An additional 32 healthy volunteers participated in a neutralization procedure to ensure the study recovery solution was non-toxic to microorganisms, and a spore-recovery procedure to demonstrate that microorganisms could be successfully recovered from the PVP-I+IPA film-forming product. RESULTS Both CHG+IPA and PVP-I+IPA produced a mean bacterial log10 reduction >2 and >3 on the abdomen and groin, respectively, 10 minutes after application. CHG+IPA maintained antimicrobial persistence out to 7 days post-application, while PVP-I+IPA maintained antimicrobial persistence out to 96 hours post-application, the longest timepoint selected for this product. CONCLUSION CHG+IPA and PVP-I+IPA were both found to be effective persistent antiseptic skin preparations. Overall, skin irritation was uncommon, and only 1 adverse event occurred following product application, which was not considered product related but was considered procedure related.
Collapse
Affiliation(s)
| | | | - Donna Werner
- Becton, Dickinson and Company; 75 N. Fairway Dr., Vernon Hills, IL 60061, USA
| | - Lingzhi Li
- Becton, Dickinson and Company; 75 N. Fairway Dr., Vernon Hills, IL 60061, USA
| | - Jonathan M Eby
- Becton, Dickinson and Company; 75 N. Fairway Dr., Vernon Hills, IL 60061, USA
| | - Erin C Zook
- Becton, Dickinson and Company; 75 N. Fairway Dr., Vernon Hills, IL 60061, USA.
| |
Collapse
|
2
|
Han AA, Buerger AN, Allen H, Vincent M, Thornton SA, Unice K, Maier A, Quiñones-Rivera A. Assessment of Ethanol Exposure from Hand Sanitizer Use and Potential for Developmental Toxicity in Nursing Infants. J Appl Toxicol 2022; 42:1424-1442. [PMID: 34991177 PMCID: PMC9543418 DOI: 10.1002/jat.4284] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 12/20/2021] [Accepted: 12/21/2021] [Indexed: 12/03/2022]
Abstract
Ingestion of ethanol during pregnancy is known to have detrimental effects on the fetus. Although the potential developmental effects of maternal ethanol intake during lactation are less well characterized, public health guidelines recommend avoidance of alcohol or, if alcohol is consumed, to allow for 1–2 h to pass before nursing. A proposal to classify ethanol as potentially harmful to breast‐fed children warrants an investigation of the potential adverse neurodevelopmental effects of low‐dose ethanol exposure during lactation. There currently are no studies that have examined neurodevelopmental outcomes from lactational exposure to ethanol from the use of topical products that contain ethanol, such as alcohol‐based hand sanitizers (ABHS). Furthermore, the epidemiological literature of lactational ethanol exposures from maternal alcohol consumption is limited in design, provides equivocal evidence of neurological effects in infants, and is insufficient to characterize a dose–response relationship for developmental effects. Toxicological studies that observed neurodevelopmental effects in pups from ethanol via lactation did so at exceedingly high doses that also caused maternal toxicity. In this investigation, blood ethanol concentrations (BECs) of breastfeeding women following typical‐to‐intense ABHS use were computationally predicted and compared to health benchmarks to quantify the risk for developmental outcomes. Margins of 2.2 to 1000 exist between BECs associated with ABHS use compared to BECs associated with neurotoxicity adverse effect levels in the toxicology literature or oral ethanol intake per public health guidelines. Neurodevelopmental effects are not likely to occur in infants due to ABHS use by breastfeeding women, even when ABHSs are used at intense frequencies. Adverse neurodevelopmental effects of ethanol exposure are supported by toxicological studies; ethanol as a potential “lactation hazard” needs evaluation. A lactation hazard may not be applicable for all ethanol‐containing products, such as hand sanitizers. Furthermore, internal dose assessments of hand sanitizer use are lacking. Computationally modeled blood ethanol concentrations following hand sanitizer use are lower than concentrations associated with toxicological and guideline benchmarks. Therefore, there is low potential for the use of ethanol‐containing hand sanitizers to be a lactation hazard.
Collapse
|
3
|
Driving under the influence of alcohol during the COVID-19 pandemic. Forensic Sci Int 2021; 329:111076. [PMID: 34736051 PMCID: PMC8539202 DOI: 10.1016/j.forsciint.2021.111076] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 10/19/2021] [Accepted: 10/21/2021] [Indexed: 11/20/2022]
Abstract
AIM The main objective of this study was to evaluate the effects of the COVID-19 pandemic on the pattern of alcohol use in drivers. MATERIALS and methods. At the National Institute of Legal Medicine from Bucharest, we performed a retrospective study on toxicology reports between January 1st, 2019 and December 31st, 2020. Breath alcohol concentration (BrAC) was tested using Dräger breathalyzers by police units at the scene, and blood alcohol concentration (BAC) was evaluated using headspace gas chromatography. Most drivers gave two blood samples, separated by a one-hour interval, case in which they could request a retrograde extrapolation of the BAC at the time when they were stopped in traffic. RESULTS The distribution of the number of cases depending on the month showed a sharp decline in the first six months of the lockdown, with a slow upward trend afterward. Mean overall values for BrAC were 0.49 +/- 0.40 mg/L, for 1st sample BAC - 1.15 +/- 0.99 g/L and for 2nd sample BAC - 1.29 +/- 0.81 g/L. Mean values obtained for BrAC were 0.48 +/- 0.39 mg/L before the pandemic and 0.52 +/- 0.43 mg/L during the pandemic. The increase was similar in absolute numbers in both male and female drivers (0.03 versus 0.04 mg/L respectively for BrAC and 0.02 g/L for both genders for 1st sample BAC). However, the percentage increase was significantly higher in women. There were 253 cases in which BrAC had values between 0.01 and 0.05, of which 138 occurred before the pandemic and 115 during the pandemic, the increase being highly statistically significant. The percentage of drivers with BAC levels below and above 0.8 g/L (the threshold value for which DUI is a felony in Romania) were similar before and during the pandemic. CONCLUSIONS During the lockdown, the number of alcohol tests in traffic has decreased significantly. This reduction was not associated with statistically significant changes in BrAC or BAC. We have seen a substantial increase in the number of minimally elevated BrAC and negative BAC cases, changes that could be caused by an increased use of alcohol-based hand sanitizers.
Collapse
|
4
|
Kosecki PA, Autret A, Abbott L, Keller-Brooke K. Isobutylene contamination of blood collected in 10-ml evacuated blood collection tubes with gray conventional rubber stoppers. J Forensic Sci 2021; 66:2484-2492. [PMID: 34250598 DOI: 10.1111/1556-4029.14792] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 05/28/2021] [Accepted: 06/03/2021] [Indexed: 11/29/2022]
Abstract
Dual-column headspace gas chromatographic analysis with two flame-ionization detectors is a commonly used analytical technique for forensic blood ethanol quantitation. This technique is also applicable to the identification and quantitation of other volatile organic compounds such as methanol in biological samples. Compound identification by retention time is limited to those compounds with known retention times programmed into the instrument method. Historically, an early-eluting peak from an unidentified compound has been observed in both chromatograms from antemortem blood samples analyzed for ethanol concentration with this technique. The unidentified compound's retention time matches that of methanol on one column but not on the second column. This previously unidentified compound has been identified as isobutylene. The proposed source of the isobutylene contamination historically observed in antemortem blood samples collected in 10-ml gray-top blood collection tubes is the conventional rubber stopper. Isobutylene was detected in deionized water stored in each of the seven lots of 10-ml blood tubes tested; the expiration dates of the tubes tested spanned the years 2002-2022. Misidentification of isobutylene as methanol is possible when using a single-column gas chromatographic system. The presence of isobutylene in blood collected in a gray-top collection tube does not represent laboratory contamination, is not an interferent with blood ethanol quantitation, and does not affect the ethanol concentration in the blood. A 0.150 g/dl aqueous ethanol standard was stored in a gray-top tube to evaluate the potential impact of isobutylene on ethanol quantitation. The solution's average ethanol concentration measured after storage was 0.150 g/dl.
Collapse
Affiliation(s)
| | - Amy Autret
- Tucson Police Department Crime Laboratory, Tucson, AZ, USA
| | - Lori Abbott
- Scottsdale Police Department Crime Laboratory, Scottsdale, AZ, USA
| | | |
Collapse
|
5
|
Kampf G, Exner M, Schwebke I, Gebel J. Ethanol is indispensable and safe as a biocidal active substance for hand disinfection. J Hosp Infect 2020; 108:205-206. [PMID: 33220347 DOI: 10.1016/j.jhin.2020.11.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 11/10/2020] [Indexed: 02/06/2023]
Affiliation(s)
- G Kampf
- University Medicine Greifswald, Institute for Hygiene and Environmental Medicine, Greifswald, Germany.
| | - M Exner
- University Bonn, Institute for Hygiene and Public Health, Bonn, Germany
| | | | - J Gebel
- University Bonn, Institute for Hygiene and Public Health, Bonn, Germany
| |
Collapse
|
6
|
Putatively lethal ingestion of isopropyl alcohol-related case: interpretation of post mortem isopropyl alcohol and acetone concentrations remains challenging. Int J Legal Med 2020; 135:175-182. [PMID: 33090260 PMCID: PMC7578436 DOI: 10.1007/s00414-020-02444-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 10/14/2020] [Indexed: 11/30/2022]
Abstract
Isopropyl alcohol, or propan-2-ol (IPA), is found in numerous chemicals including alcohol-based hand rubs whose use has been recently widely extended to the general population since the onset of the COVID-19 pandemic. This widespread of IPA use could potentially, but not necessarily, be responsible for an increase in IPA poisoning cases (e.g., in alcoholics and/or for suicide attempt, even more in a lockdown situation). Forensic identification of IPA-related fatalities remains challenging as IPA post mortem detection can also result from antemortem or post mortem production, or post mortem contamination. In order to illustrate this issue, we report the case of a 33-year-old man found dead with a bottle of pure IPA liquid close to him. Toxicological positive results only consisted in IPA (464, 260, 465 and 991 mg/L) and acetone (1560, 2340, 3040 and 1360 mg/L) in blood, vitreous humour, urine and bile, respectively (determinations using headspace gas chromatography with flame ionization detection). These IPA absolute concentrations and IPA-to-acetone ratios appear inferior to those usually reported in the literature (higher than 1000 mg/L and 1.1, respectively) in IPA poisoning cases. In conclusion, this death can be cautiously regarded as an IPA ingestion-related fatality in the hypothesis of a survival time which have promoted IPA metabolism to acetone: this hypothesis is supported by the putative limited IPA-ingested dose. This report emphasizes the fact that post mortem IPA and acetone concentration interpretation involves to take account of (i) results in multiple biological specimens, (ii) complete case history, and (iii) a search of possible IPA presence at the scene of death.
Collapse
|
7
|
Dear K, Grayson L, Nixon R. Potential methanol toxicity and the importance of using a standardised alcohol-based hand rub formulation in the era of COVID-19. Antimicrob Resist Infect Control 2020; 9:129. [PMID: 32771064 PMCID: PMC7414286 DOI: 10.1186/s13756-020-00788-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Accepted: 07/21/2020] [Indexed: 01/14/2023] Open
Abstract
OBJECTIVES Hand sanitisers are urgently needed in the time of COVID-19, and as a result of shortages, some people have resorted to making their own formulations, including the repurposing of distilleries. We wish to highlight the importance of those producing hand sanitisers to avoid methylated spirits containing methanol and to follow WHO recommended formulations. METHODS We explore and discuss reports of methanol toxicity through ingestion and transdermal absorption. We discuss the WHO formulations and explain the rationale behind the chosen ingredients. SHORT CONCLUSION We advise those producing hand sanitisers to follow WHO recommended formulations, and advise those producing hand sanitisers using methylated spirits, to avoid formulations which contain methanol.
Collapse
Affiliation(s)
- K Dear
- Occupational Dermatology Research and Education Centre, Skin Health Institute, Level 1/80 Drummond Street, Melbourne, Australia
| | - L Grayson
- University of Melbourne, Parkville, Victoria, Australia
| | - R Nixon
- Occupational Dermatology Research and Education Centre, Skin Health Institute, Level 1/80 Drummond Street, Melbourne, Australia.
- Australia and University of Melbourne, Parkville, Victoria, Australia.
| |
Collapse
|
8
|
Brewer C, Streel E. Is Alcohol in Hand Sanitizers Absorbed Through the Skin or Lungs? Implications for Disulfiram Treatment. Alcohol Alcohol 2020; 55:354-356. [PMID: 32400852 PMCID: PMC7454269 DOI: 10.1093/alcalc/agaa045] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 04/24/2020] [Accepted: 04/29/2020] [Indexed: 12/03/2022] Open
Abstract
Aim In view of the increase in the use of ethanol-containing hand sanitizers throughout the world due to the current COVID-19 pandemic, we wished to review the possible risks to patients treated with disulfiram, following a case report in which an apparent DER (disulfiram–ethanol reaction) was attributed to the cutaneous absorption of alcohol from hand sanitizers as well as by inhalation of vapour. Method Simple experiments to assess the levels of absorption by each route separately. Results Our results strongly suggest that while amounts of alcohol sufficient to cause a DER may be inhaled when hand sanitizers are used in confined spaces, absorption can be avoided by dispersal of the fumes, and absorption from the skin alone does not occur in pharmacologically significant quantities. Conclusion Warnings about absorption of alcohol through the skin from hand sanitizers and products such as perfumes, deodorants and after-shave (whose use is often warned against when disulfiram is prescribed) should be modified accordingly.
Collapse
Affiliation(s)
- Colin Brewer
- Retired Psychiatrist and addiction Physician, London, SE1, London, UK
| | - Emmanuel Streel
- CHU Brugmann, Free University of Brussels, 1020, Brussels, Belgium
| |
Collapse
|
9
|
Kang DW, Ilhan ZE, Isern NG, Hoyt DW, Howsmon DP, Shaffer M, Lozupone CA, Hahn J, Adams JB, Krajmalnik-Brown R. Differences in fecal microbial metabolites and microbiota of children with autism spectrum disorders. Anaerobe 2018; 49:121-131. [DOI: 10.1016/j.anaerobe.2017.12.007] [Citation(s) in RCA: 137] [Impact Index Per Article: 22.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Revised: 11/01/2017] [Accepted: 12/18/2017] [Indexed: 12/30/2022]
|
10
|
Jensen DA, Macinga DR, Shumaker DJ, Bellino R, Arbogast JW, Schaffner DW. Quantifying the Effects of Water Temperature, Soap Volume, Lather Time, and Antimicrobial Soap as Variables in the Removal of Escherichia coli ATCC 11229 from Hands. J Food Prot 2017; 80:1022-1031. [PMID: 28504614 DOI: 10.4315/0362-028x.jfp-16-370] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The literature on hand washing, while extensive, often contains conflicting data, and key variables are only superficially studied or not studied at all. Some hand washing recommendations are made without scientific support, and agreement between recommendations is limited. The influence of key variables such as soap volume, lather time, water temperature, and product formulation on hand washing efficacy was investigated in the present study. Baseline conditions were 1 mL of a bland (nonantimicrobial) soap, a 5-s lather time, and 38°C (100°F) water temperature. A nonpathogenic strain of Escherichia coli (ATCC 11229) was the challenge microorganism. Twenty volunteers (10 men and 10 women) participated in the study, and each test condition had 20 replicates. An antimicrobial soap formulation (1% chloroxylenol) was not significantly more effective than the bland soap for removing E. coli under a variety of test conditions. Overall, the mean reduction was 1.94 log CFU (range, 1.83 to 2.10 log CFU) with the antimicrobial soap and 2.22 log CFU (range, 1.91 to 2.54 log CFU) with the bland soap. Overall, lather time significantly influenced efficacy in one scenario, in which a 0.5-log greater reduction was observed after 20 s with bland soap compared with the baseline wash (P = 0.020). Water temperature as high as 38°C (100°F) and as low as 15°C (60°F) did not have a significant effect on the reduction of bacteria during hand washing; however, the energy usage differed between these temperatures. No significant differences were observed in mean log reductions experienced by men and women (both 2.08 log CFU; P = 0.988). A large part of the variability in the data was associated with the behaviors of the volunteers. Understanding what behaviors and human factors most influence hand washing may help researchers find techniques to optimize the effectiveness of hand washing.
Collapse
Affiliation(s)
- Dane A Jensen
- 1 Department of Food Science, Rutgers University, 65 Dudley Road, New Brunswick, New Jersey 08901-8520
| | - David R Macinga
- 2 GOJO Industries, Inc., 1 GOJO Plaza #500, Akron, Ohio 44311, USA
| | - David J Shumaker
- 2 GOJO Industries, Inc., 1 GOJO Plaza #500, Akron, Ohio 44311, USA
| | - Roberto Bellino
- 2 GOJO Industries, Inc., 1 GOJO Plaza #500, Akron, Ohio 44311, USA
| | - James W Arbogast
- 2 GOJO Industries, Inc., 1 GOJO Plaza #500, Akron, Ohio 44311, USA
| | - Donald W Schaffner
- 1 Department of Food Science, Rutgers University, 65 Dudley Road, New Brunswick, New Jersey 08901-8520
| |
Collapse
|
11
|
MacLean RR, Valentine GW, Jatlow PI, Sofuoglu M. Inhalation of Alcohol Vapor: Measurement and Implications. Alcohol Clin Exp Res 2017; 41:238-250. [PMID: 28054395 DOI: 10.1111/acer.13291] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2016] [Accepted: 11/08/2016] [Indexed: 02/06/2023]
Abstract
Decades of alcohol research have established the health risks and pharmacodynamic profile of oral alcohol consumption. Despite isolated periods of public health concern, comparatively less research has evaluated exposure to alcohol vapor. Inhaled alcohol initially bypasses first-pass metabolism and rapidly reaches the arterial circulation and the brain, suggesting that this route of administration may be associated with pharmacological effects that increase the risk of addiction. However, detailed reviews assessing the possible effects of inhaled alcohol in humans are lacking. A comprehensive, systematic literature review was conducted using Google Scholar and PubMed to examine manuscripts studying exposure to inhaled alcohol and measurement of biomarkers (biochemical or functional) associated with alcohol consumption in human participants. Twenty-one publications reported on alcohol inhalation. Fourteen studies examined inhalation of alcohol vapor associated with occupational exposure (e.g., hand sanitizer) in a variety of settings (e.g., naturalistic, laboratory). Six publications measured inhalation of alcohol in a controlled laboratory chamber, and 1 evaluated direct inhalation of an e-cigarette with ethanol-containing "e-liquid." Some studies have reported that inhalation of alcohol vapor results in measurable biomarkers of acute alcohol exposure, most notably ethyl glucuronide. Despite the lack of significantly elevated blood alcohol concentrations, the behavioral consequences and subjective effects associated with repeated use of devices capable of delivering alcohol vapor are yet to be determined. No studies have focused on vulnerable populations, such as adolescents or individuals with alcohol use disorder, who may be most at risk of problems associated with alcohol inhalation.
Collapse
Affiliation(s)
- Robert Ross MacLean
- Department of Psychiatry, School of Medicine, Yale University, West Haven, Connecticut.,VA Connecticut Healthcare System, West Haven, Connecticut
| | - Gerald W Valentine
- Department of Psychiatry, School of Medicine, Yale University, West Haven, Connecticut.,VA Connecticut Healthcare System, West Haven, Connecticut
| | - Peter I Jatlow
- Laboratory Medicine, Yale University, West Haven, Connecticut
| | - Mehmet Sofuoglu
- Department of Psychiatry, School of Medicine, Yale University, West Haven, Connecticut.,VA Connecticut Healthcare System, West Haven, Connecticut
| |
Collapse
|
12
|
Emerson BL, Whitfill T, Baum CR, Garlin-Kane K, Santucci K. Effects of alcohol-based hand hygiene solutions on breath alcohol detection in the emergency department. Am J Infect Control 2016; 44:1672-1674. [PMID: 27614708 DOI: 10.1016/j.ajic.2016.05.036] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2016] [Revised: 05/27/2016] [Accepted: 05/27/2016] [Indexed: 11/17/2022]
Abstract
This study aimed to investigate the effects of alcohol-based hand hygiene solution (ABHS) use by care providers on point-of-care alcohol breath analyzer interpretation under different clinically relevant conditions. Among each test condition (foam vehicle with immediate testing, gel vehicle with immediate testing, allowing hands to dry after the use of ABHS, and donning gloves after the use of ABHS), alcohol was detected in breath at 1 minute after use of ABHS. Because the use of ABHS by individuals administering breath alcohol detection may result in false-positive detection of alcohol, staff using these devices should consider traditional hand hygiene with soap and water.
Collapse
Affiliation(s)
- Beth L Emerson
- Section of Pediatric Emergency Medicine, Yale University School of Medicine, New Haven, CT.
| | - Travis Whitfill
- Section of Pediatric Emergency Medicine, Yale University School of Medicine, New Haven, CT
| | - Carl R Baum
- Section of Pediatric Emergency Medicine, Yale University School of Medicine, New Haven, CT
| | | | - Karen Santucci
- Section of Pediatric Emergency Medicine, Yale University School of Medicine, New Haven, CT
| |
Collapse
|
13
|
Pires D, Bellissimo-Rodrigues F, Pittet D. Ethanol-based handrubs: Safe for patients and health care workers. Am J Infect Control 2016; 44:858-9. [PMID: 27091229 DOI: 10.1016/j.ajic.2016.02.016] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Accepted: 02/17/2016] [Indexed: 01/24/2023]
Affiliation(s)
- Daniela Pires
- Infection Control Programme and World Health Organization (WHO) Collaborating Centre on Patient Safety, Infection Control & Improving Practices, University of Geneva Hospitals and Faculty of Medicine, Geneva, Switzerland; Department of Infectious Diseases, Centro Hospitalar Lisboa Norte and Faculdade de Medicina da Universidade de Lisboa, Lisbon, Portugal
| | - Fernando Bellissimo-Rodrigues
- Infection Control Programme and World Health Organization (WHO) Collaborating Centre on Patient Safety, Infection Control & Improving Practices, University of Geneva Hospitals and Faculty of Medicine, Geneva, Switzerland; Social Medicine Department, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, São Paulo, Brazil
| | - Didier Pittet
- Infection Control Programme and World Health Organization (WHO) Collaborating Centre on Patient Safety, Infection Control & Improving Practices, University of Geneva Hospitals and Faculty of Medicine, Geneva, Switzerland.
| |
Collapse
|
14
|
Breath alcohol of anesthesiologists using alcohol hand gel and the “five moments for hand hygiene” in routine practice. Can J Anaesth 2016; 63:938-44. [DOI: 10.1007/s12630-016-0666-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Revised: 03/12/2016] [Accepted: 04/22/2016] [Indexed: 10/21/2022] Open
|
15
|
Safety assessment for ethanol-based topical antiseptic use by health care workers: Evaluation of developmental toxicity potential. Regul Toxicol Pharmacol 2015. [PMID: 26212636 DOI: 10.1016/j.yrtph.2015.07.015] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Ethanol-based topical antiseptic hand rubs, commonly referred to as alcohol-based hand sanitizers (ABHS), are routinely used as the standard of care to reduce the presence of viable bacteria on the skin and are an important element of infection control procedures in the healthcare industry. There are no reported indications of safety concerns associated with the use of these products in the workplace. However, the prevalence of such alcohol-based products in healthcare facilities and safety questions raised by the U.S. FDA led us to assess the potential for developmental toxicity under relevant product-use scenarios. Estimates from a physiologically based pharmacokinetic modeling approach suggest that occupational use of alcohol-based topical antiseptics in the healthcare industry can generate low, detectable concentrations of ethanol in blood. This unintended systemic dose probably reflects contributions from both dermal absorption and inhalation of volatilized product. The resulting internal dose is low, even under hypothetical, worst case intensive use assumptions. A significant margin of exposure (MOE) exists compared to demonstrated effect levels for developmental toxicity under worst case use scenarios, and the MOE is even more significant for typical anticipated occupational use patterns. The estimated internal doses of ethanol from topical application of alcohol-based hand sanitizers are also in the range of those associated with consumption of non-alcoholic beverages (i.e., non-alcoholic beer, flavored water, and orange juice), which are considered safe for consumers. Additionally, the estimated internal doses associated with expected exposure scenarios are below or in the range of the expected internal doses associated with the current occupational exposure limit for ethanol set by the Occupational Safety and Health Administration. These results support the conclusion that there is no significant risk of developmental or reproductive toxicity from repeated occupational exposures and high frequency use of ABHSs or surgical scrubs. Overall, the data support the conclusion that alcohol-based hand sanitizer products are safe for their intended use in hand hygiene as a critical infection prevention strategy in healthcare settings.
Collapse
|
16
|
Alcohol congener analysis and the source of alcohol: a review. Forensic Sci Med Pathol 2013; 9:194-207. [DOI: 10.1007/s12024-013-9411-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/31/2013] [Indexed: 12/20/2022]
|
17
|
Hautemanière A, Ahmed-Lecheheb D, Cunat L, Hartemann P. Assessment of transpulmonary absorption of ethanol from alcohol-based hand rub. Am J Infect Control 2013; 41:e15-9. [PMID: 23332374 DOI: 10.1016/j.ajic.2012.09.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2012] [Revised: 08/24/2012] [Accepted: 09/04/2012] [Indexed: 11/26/2022]
Abstract
BACKGROUND Alcohol-based hand rubs (ABHRs) have been associated with a reduction of nosocomial infections. Despite the worldwide introduction of these products in health care settings, the aim of this study was to assess the transpulmonary absorption of ethanol contains in ABHRs used by health care workers (HCWs) in real conditions of work shift. METHODS Twenty-six HCWs of Nancy University Hospital were included. Research consisted in monitoring participants during 4 hours of work shift to assess their exposure to ethanol. The measurement of ethanol vapors in exhaled breath was performed using a class B ethylometer (Alco-Sensor FST). Ethanol concentration in inhaled breath was measured using Gilian pump LFS-113. Concentration of ethanol, acetaldehyde, and acetate in blood and urine samples were determined using gas chromatography with flame ionization detector. RESULTS Participants were 12% male and 88% female. The mean age was 40 ± 8 years. None of the employees included in the study presented any traces of ethanol or its metabolites in the blood or urine. Ethanol (0.08 ± 0.07 mg/L) was detected in the breath of 10 HCWs at 1 to 2 minutes postexposure. The mean concentration of ethanol in the inhaled air was 46.2 mg/m. CONCLUSION Absorption of ethanol vapor from ABHRs among HCWs during their care activities was not detected. Quantification of ethanol fumes inhaled during 4 hours of work shift was below the regulatory limitations of exposure to ethanol.
Collapse
|
18
|
Ali SS, Wilson MP, Castillo EM, Witucki P, Simmons TT, Vilke GM. Common hand sanitizer may distort readings of breathalyzer tests in the absence of acute intoxication. Acad Emerg Med 2013; 20:212-5. [PMID: 23406081 DOI: 10.1111/acem.12073] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2012] [Revised: 08/14/2012] [Accepted: 08/22/2012] [Indexed: 12/01/2022]
Abstract
OBJECTIVES The use of alcohol-based hand sanitizers has recently become widespread. To the authors' knowledge, no previous study has examined whether application of ethanol-based hand sanitizers by the person operating a common breathalyzer machine will affect the accuracy of the readings. This was a prospective study investigating whether the use of hand sanitizer applied according to manufacturer's recommendations (Group I), applied improperly at standard doses (Group II), or applied improperly at high doses (Group III) had an effect on breathalyzer readings of individuals who had not ingested alcohol. METHODS The participants of the prospective study were divided into three groups to assess the effect of hand sanitizer on breathalyzer readings. Group I used one pump (1.5 mL) of hand sanitizer (Purell), allowing the hands to dry per manufacturer's recommendations; Group II used one pump (1.5 mL), without allowing the hands to dry; and Group III used two pumps (3 mL), without allowing the hands to dry. Breathalyzer measures for each group are presented as medians with interquartile ranges (IQR) and ranges. Differences between each sequential group (I vs. II and II vs. III) were assessed using a Mann-Whitney U-test (p < 0.05 significant). RESULTS There were 25 study participants in each group for a total of 75 participants. The initial breathalyzer readings of all study participants were 0.000 g/dL. The median breathalyzer reading was 0.004 g/dL in Group I (IQR = 0.001 to 0.008 g/dL), 0.051 g/dL in Group II (IQR = 0.043 to 0.064 g/dL), and 0.119 g/dL in Group III (IQR = 0.089 to 0.134 g/dL). Measures between each subsequent group were all statistically different (p < 0.001). CONCLUSIONS The use of common alcohol-based hand sanitizer may cause false-positive readings with a standard hospital breathalyzer when the operator uses the hand sanitizer correctly. The breathalyzer readings are further elevated if more sanitizer is used or if it is not allowed to dry appropriately.
Collapse
Affiliation(s)
| | | | | | - Peter Witucki
- the Department of Emergency Medicine; UC San Diego Health System; San Diego; CA
| | - Todd T. Simmons
- the Department of Emergency Medicine; UC San Diego Health System; San Diego; CA
| | | |
Collapse
|
19
|
Hand hygiene and healthcare system change within multi-modal promotion: a narrative review. J Hosp Infect 2013; 83 Suppl 1:S3-10. [DOI: 10.1016/s0195-6701(13)60003-1] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
20
|
Hautemanière A, Cunat L, Ahmed-Lecheheb D, Hajjard F, Gerardin F, Morele Y, Hartemann P. Assessment of exposure to ethanol vapors released during use of Alcohol-Based Hand Rubs by healthcare workers. J Infect Public Health 2012; 6:16-26. [PMID: 23290089 DOI: 10.1016/j.jiph.2012.09.015] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2012] [Revised: 09/11/2012] [Accepted: 09/22/2012] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Despite the increasing use of Alcohol-Based Hand Rub solutions, few studies have quantified the concentrations of inhaled ethanol. OBJECTIVE The aim of this study was to assess ethanol exposure during hygienic and surgical hand disinfection practices. METHOD Ethanol concentrations were measured at the nose level of a wooden dummy and human volunteers. Two systems were used in parallel to determine short-term ethanol vapor exposures: activated charcoal tubes followed by gas chromatography analysis and direct reading on a photoionization detector (PID). Exposure was assessed for 4 different sequences (N=10) reproducing hand rubs for simple surgery, nursing care, intensive care and surgical scrub. RESULTS The ethanol concentrations measured were of a similar order between the dummy and volunteers. The concentrations obtained by PID were higher than the gas chromatography values for the simple care (45%) and nursing care (27%) sequences and reflected specific exposure peaks of ethanol, whereas ethanol concentrations were continuously high for intensive care (440 mg m(-3)) or surgical scrub (650 mg m(-3)). CONCLUSION Ethanol concentrations were similar for these two exposure assessment methods and demonstrated a relationship between handled doses and inhaled doses. However, the ethanol vapors released during hand disinfection were safe for the healthcare workers.
Collapse
|
21
|
Huynh-Delerme C, Artigou C, Bodin L, Tardif R, Charest-Tardif G, Verdier C, Sater N, Ould-Elhkim M, Desmares C. Short Communication: Is Ethanol-Based Hand Sanitizer Involved in Acute Pancreatitis after Excessive Disinfection?-An Evaluation with the Use of PBPK Model. J Toxicol 2012; 2012:959070. [PMID: 22577377 PMCID: PMC3345231 DOI: 10.1155/2012/959070] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2011] [Accepted: 02/06/2012] [Indexed: 12/02/2022] Open
Abstract
An occupational physician reported to the French Health Products Safety Agency (Afssaps) a case of adverse effect of acute pancreatitis (AP) in a teaching nurse, after multiple demonstrations with ethanol-based hand sanitizers (EBHSs) used in a classroom with defective mechanical ventilation. It was suggested by the occupational physician that the exposure to ethanol may have produced a significant blood ethanol concentration and subsequently the AP. In order to verify if the confinement situation due to defective mechanical ventilation could increase the systemic exposure to ethanol via inhalation route, a physiologically based pharmacokinetic (PBPK) modeling was used to predict ethanol blood levels. Under the worst case scenario, the simulation by PBPK modeling showed that the maximum blood ethanol concentration which can be predicted of 5.9 mg/l is of the same order of magnitude to endogenous ethanol concentration (mean = 1.1 mg/L; median = 0.4 mg/L; range = 0-35 mg/L) in nondrinker humans (Al-Awadhi et al., 2004). The present study does not support the likelihood that EBHS leads to an increase in systemic ethanol concentration high enough to provoke an acute pancreatitis.
Collapse
Affiliation(s)
- Céline Huynh-Delerme
- Department of Cosmetic, Biocide, and Tatoo Products, French Health Products Safety Agency (Afssaps), 143-147 Boulevard Anatole France, 93285 Saint-Denis Cedex, France
| | - Catherine Artigou
- Department of Cosmetic, Biocide, and Tatoo Products, French Health Products Safety Agency (Afssaps), 143-147 Boulevard Anatole France, 93285 Saint-Denis Cedex, France
| | - Laurent Bodin
- Department of Risk Assessment, French Agency for Food, Environmental and Occupational Health Safety (Anses), 24-31 Avenue du Général Leclerc, 94701 Maisons-Alfort Cedex, France
| | - Robert Tardif
- Département de Santé Environnementale et Santé au Travail, Faculté de Médecine, Université de Montréal, Montréal, QC, Canada 3J7 H3C
| | - Ginette Charest-Tardif
- Département de Santé Environnementale et Santé au Travail, Faculté de Médecine, Université de Montréal, Montréal, QC, Canada 3J7 H3C
| | - Cécile Verdier
- Department of Cosmetic, Biocide, and Tatoo Products, French Health Products Safety Agency (Afssaps), 143-147 Boulevard Anatole France, 93285 Saint-Denis Cedex, France
| | - Nessryne Sater
- Department of Cosmetic, Biocide, and Tatoo Products, French Health Products Safety Agency (Afssaps), 143-147 Boulevard Anatole France, 93285 Saint-Denis Cedex, France
| | - Mostafa Ould-Elhkim
- Department of Cosmetic, Biocide, and Tatoo Products, French Health Products Safety Agency (Afssaps), 143-147 Boulevard Anatole France, 93285 Saint-Denis Cedex, France
| | - Catherine Desmares
- Department of Cosmetic, Biocide, and Tatoo Products, French Health Products Safety Agency (Afssaps), 143-147 Boulevard Anatole France, 93285 Saint-Denis Cedex, France
| |
Collapse
|
22
|
Below H, Partecke I, Huebner NO, Bieber N, Nicolai T, Usche A, Assadian O, Below E, Kampf G, Parzefall W, Heidecke CD, Zuba D, Bessonneau V, Kohlmann T, Kramer A. Dermal and pulmonary absorption of propan-1-ol and propan-2-ol from hand rubs. Am J Infect Control 2012; 40:250-7. [PMID: 21741120 DOI: 10.1016/j.ajic.2011.03.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2011] [Revised: 03/06/2011] [Accepted: 03/07/2011] [Indexed: 10/18/2022]
Abstract
BACKGROUND It has been shown that nontoxic concentrations of ethanol are absorbed after hand hygiene using ethanol-based hand rubs. This study investigated whether absorption of propan-1-ol and propan-2-ol from commercially available hand rubs results in measurable concentrations after use. METHODS The pulmonary and dermal absorption of propanol during hand rubs was investigated. Rubs contained 70% (w/w) propan-1-ol, 63.14% (w/w) propan-2-ol, or 45% (w/w) propan-2-ol in combination with 30% (w/w) propan-1-ol. RESULTS Peak median blood levels were 9.15 mg/L for propan-1-ol and 5.3 mg/L for propan-2-ol after hygienic hand rubs and 18.0 mg/L and 10.0 mg/L, respectively, after surgical hand rubs. Under actual surgical conditions, the highest median blood levels were 4.08 mg/L for propan-1-ol and 2.56 mg/L for propan-2-ol. The same procedure performed with prevention of pulmonary exposure through the use of a gas-tight mask resulted in peak median blood levels of 1.16 mg/L of propan-1-ol and 1.74 mg/L of propan-2-ol. CONCLUSION Only minimal amounts of propanols are absorbed through the use of hand rubs. Based on our experimental data, the risk of chronic systemic toxic effects caused by hand rubs is likely negligible. However, our study did not evaluate the consequences of long-term daily and frequent use of hygienic hand rubs.
Collapse
|
23
|
Stewardson A, Allegranzi B, Sax H, Kilpatrick C, Pittet D. Back to the future: rising to the Semmelweis challenge in hand hygiene. Future Microbiol 2011; 6:855-76. [PMID: 21861619 DOI: 10.2217/fmb.11.66] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Hand hygiene is the single most important intervention for reducing healthcare associated infections and preventing the spread of antimicrobial resistance. This sentence begins most publications regarding hand hygiene in the medical literature. But why - as we mark 150 years since the publication of Ignaz Semmelweis' landmark monograph on the subject - do we continue to repeat it? One might be tempted to regard it as a truism. However, while tremendous progress has certainly been made in this field, a significant amount of work is yet to be done in both strengthening the evidence regarding the impact of hand hygiene and maximizing its implementation. Hand hygiene cannot yet be taken for granted. This article summarizes historical perspectives, dynamics of microbial colonization and efficacy of hand cleansing methods and agents, elements and impacts of successful hand hygiene promotion, as well as scale-up and sustainability. We also explore hand hygiene myths and current challenges such as monitoring, behavior change, patient participation and research priorities.
Collapse
Affiliation(s)
- Andrew Stewardson
- Infection Control Program & World Health Organization Collaborating Centre on Patient Safety (Infection Control & Practice Improvement), University of Geneva Hospitals, Switzerland
| | | | | | | | | |
Collapse
|
24
|
Carignan D, Désy O, de Campos-Lima PO. The dysregulation of the monocyte/macrophage effector function induced by isopropanol is mediated by the defective activation of distinct members of the AP-1 family of transcription factors. Toxicol Sci 2011; 125:144-56. [PMID: 22020770 DOI: 10.1093/toxsci/kfr283] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Isopropanol is the second most common cause of short-chain alcohol acute intoxication. Nonethanolic short-chain alcohols mediate their immunomodulatory effect by interfering with nuclear factor of activated T cells (NFAT) activation with or without additional activator protein-1 (AP-1) involvement. In the present study, we examined the immunomodulation induced by isopropanol in conditions that are not reliant on NFAT: the inflammatory cytokine response of lipopolysaccharide (LPS)-stimulated monocytes. Our hypothesis was that isopropanol acute exposure would have an attenuated effect or no consequence in this setting. To our surprise, the impairment of AP-1 activation was sufficient to mediate a severe and dose-dependent phenotype in human monocytes in vitro at alcohol concentrations as low as 0.16% (or 26 mM). There were three outcomes: interleukin (IL)-1β/IL-8 were unaltered; IL-6 was upregulated; and tumor necrosis factor alpha (TNF-α)/CCL2 were downregulated. The effector function of human monocyte-derived macrophages was also compromised. Our results showed that Toll-like receptor 4 early signaling was preserved, as isopropanol did not change the kinase activity of the IL-1 receptor-associated kinase 1 in LPS-stimulated cells. The nuclear factor-κB signaling cascade and the p38/c-Jun N-terminal kinase modules of the mitogen-activated protein kinase pathway were alcohol insensitive. Conversely, the activation of extracellular signal-regulated protein kinase and, ultimately, of c-Fos and JunB were impaired. The alcohol-induced cytokine dysregulation was confirmed in a mouse model of isopropanol intoxication in which the production of TNF-α in response to LPS challenge was virtually abolished. The magnitude of this alcohol effect was sufficiently high to rescue animals from LPS-induced toxic shock. Our data contribute to the dismal body of information on the immunotoxicology of isopropanol, one of the most ubiquitous chemicals to which the general population is significantly exposed.
Collapse
Affiliation(s)
- Damien Carignan
- Laval University Cancer Research Center, Quebec City, Quebec G1R 2J6, Canada
| | | | | |
Collapse
|
25
|
Nandrup-Bus I. Comparative studies of hand disinfection and handwashing procedures as tested by pupils in intervention programs. Am J Infect Control 2011; 39:450-5. [PMID: 21802616 DOI: 10.1016/j.ajic.2010.10.023] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2010] [Revised: 10/18/2010] [Accepted: 10/18/2010] [Indexed: 11/19/2022]
Abstract
BACKGROUND The objective of this study was to determine the effect of mandatory, scheduled hand disinfection (HD) on actual absenteeism because of infectious illness in elementary school pupils in Denmark. METHODS A 3-month intervention study between 2 schools was performed on 656 pupils ages 5 to 15 years. The pupils at the intervention school (IS; n = 318) were required to disinfect their hands 3 times during school hours. Those at the control school (CS; n = 338) continued their usual handwashing (HW) practices, but they had been IS regarding mandatory HW the previous year. All absences because of illness were recorded, and data were analyzed statistically. RESULTS Comparison between the IS and itself (CS in 2007) demonstrated a significant difference (P = .018) in reducing absenteeism because of infectious illness, both for girls (P = .011) and boys (P = .029). The CS (IS in 2007) did not show any difference between 2007 and 2008 (P = .86). CONCLUSION Intervention with mandatory HW may have a lasting pedagogical effect in reducing absenteeism because of infectious illness when exposed to role models. HD could be effective in reducing absenteeism because of infectious illness and a well-placed supplement to HW.
Collapse
|
26
|
Religion and culture: potential undercurrents influencing hand hygiene promotion in health care. Am J Infect Control 2009; 37:28-34. [PMID: 18834738 PMCID: PMC7115273 DOI: 10.1016/j.ajic.2008.01.014] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2007] [Revised: 01/10/2008] [Accepted: 01/11/2008] [Indexed: 11/08/2022]
Abstract
Background Health care–associated infections affect hundreds of millions of patients worldwide each year. The World Health Organization's (WHO) First Global Patient Safety Challenge, “Clean Care is Safer Care,” is tackling this major patient safety problem, with the promotion of hand hygiene in health care as the project's cornerstone. WHO Guidelines on Hand Hygiene in Healthcare have been prepared by a large group of international experts and are currently in a pilot-test phase to assess feasibility and acceptability in different health care settings worldwide. Methods An extensive literature search was conducted and experts and religious authorities were consulted to investigate religiocultural factors that may potentially influence hand hygiene promotion, offer possible solutions, and suggest areas for future research. Results Religious faith and culture can strongly influence hand hygiene behavior in health care workers and potentially affect compliance with best practices. Interesting data were retrieved on specific indications for hand cleansing according to the 7 main religions worldwide, interpretation of hand gestures, the concept of “visibly dirty” hands, and the use of alcohol-based hand rubs and prohibition of alcohol use by some religions. Conclusions The impact of religious faith and cultural specificities must be taken into consideration when implementing a multimodal strategy to promote hand hygiene on a global scale.
Collapse
|
27
|
Kauffman D, Star A. Gas- und Dampfsensoren auf der Basis von Kohlenstoff-Nanoröhren. Angew Chem Int Ed Engl 2008. [DOI: 10.1002/ange.200704488] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
28
|
Affiliation(s)
- Douglas R Kauffman
- Department of Chemistry, University of Pittsburgh and The National Energy Technology Laboratory, Pittsburgh, PA, USA
| | | |
Collapse
|