1
|
Strohmaier-Nguyen D, Horn C, Baeumner AJ. Sample-to-answer lateral flow assay with integrated plasma separation and NT-proBNP detection. Anal Bioanal Chem 2024; 416:3107-3115. [PMID: 38589616 PMCID: PMC11068687 DOI: 10.1007/s00216-024-05271-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 03/20/2024] [Accepted: 03/22/2024] [Indexed: 04/10/2024]
Abstract
Through enabling whole blood detection in point-of-care testing (POCT), sedimentation-based plasma separation promises to enhance the functionality and extend the application range of lateral flow assays (LFAs). To streamline the entire process from the introduction of the blood sample to the generation of quantitative immune-fluorescence results, we combined a simple plasma separation technique, an immunoreaction, and a micropump-driven external suction control system in a polymer channel-based LFA. Our primary objective was to eliminate the reliance on sample-absorbing separation membranes, the use of active separation forces commonly found in POCT, and ultimately allowing finger prick testing. Combining the principle of agglutination of red blood cells with an on-device sedimentation-based separation, our device allows for the efficient and fast separation of plasma from a 25-µL blood volume within a mere 10 min and overcomes limitations such as clogging, analyte adsorption, and blood pre-dilution. To simplify this process, we stored the agglutination agent in a dried state on the test and incorporated a filter trench to initiate sedimentation-based separation. The separated plasma was then moved to the integrated mixing area, initiating the immunoreaction by rehydration of probe-specific fluorophore-conjugated antibodies. The biotinylated immune complex was subsequently trapped in the streptavidin-rich detection zone and quantitatively analyzed using a fluorescence microscope. Normalized to the centrifugation-based separation, our device demonstrated high separation efficiency of 96% and a yield of 7.23 µL (= 72%). Furthermore, we elaborate on its user-friendly nature and demonstrate its proof-of-concept through an all-dried ready-to-go NT-proBNP lateral flow immunoassay with clinical blood samples.
Collapse
Affiliation(s)
- Dan Strohmaier-Nguyen
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053, Regensburg, Germany
| | - Carina Horn
- Roche Diagnostics GmbH, 68305, Mannheim, Germany
| | - Antje J Baeumner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053, Regensburg, Germany.
| |
Collapse
|
2
|
Sabra DM, Krin A, Romeral AB, Frieß JL, Jeremias G. Anthrax revisited: how assessing the unpredictable can improve biosecurity. Front Bioeng Biotechnol 2023; 11:1215773. [PMID: 37795173 PMCID: PMC10546327 DOI: 10.3389/fbioe.2023.1215773] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 07/24/2023] [Indexed: 10/06/2023] Open
Abstract
B. anthracis is one of the most often weaponized pathogens. States had it in their bioweapons programs and criminals and terrorists have used or attempted to use it. This study is motivated by the narrative that emerging and developing technologies today contribute to the amplification of danger through greater easiness, accessibility and affordability of steps in the making of an anthrax weapon. As states would have way better preconditions if they would decide for an offensive bioweapons program, we focus on bioterrorism. This paper analyzes and assesses the possible bioterrorism threat arising from advances in synthetic biology, genome editing, information availability, and other emerging, and converging sciences and enabling technologies. Methodologically we apply foresight methods to encourage the analysis of contemporary technological advances. We have developed a conceptual six-step foresight science framework approach. It represents a synthesis of various foresight methodologies including literature review, elements of horizon scanning, trend impact analysis, red team exercise, and free flow open-ended discussions. Our results show a significant shift in the threat landscape. Increasing affordability, widespread distribution, efficiency, as well as ease of use of DNA synthesis, and rapid advances in genome-editing and synthetic genomic technologies lead to an ever-growing number and types of actors who could potentially weaponize B. anthracis. Understanding the current and future capabilities of these technologies and their potential for misuse critically shapes the current and future threat landscape and underlines the necessary adaptation of biosecurity measures in the spheres of multi-level political decision making and in the science community.
Collapse
Affiliation(s)
- Dunja Manal Sabra
- Carl Friedrich von Weizsäcker-Centre for Science and Peace Research (ZNF), University of Hamburg, Bogenallee, Hamburg, Germany
| | | | | | | | | |
Collapse
|
3
|
Harpak N, Borberg E, Raz A, Patolsky F. The "Bloodless" Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers. ACS NANO 2022; 16:13800-13813. [PMID: 36006419 PMCID: PMC9527802 DOI: 10.1021/acsnano.2c01793] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Accepted: 08/22/2022] [Indexed: 06/15/2023]
Abstract
Protein biomarkers' detection is of utmost importance for preventive medicine and early detection of illnesses. Today, their detection relies entirely on clinical tests consisting of painful, invasive extraction of large volumes of venous blood; time-consuming postextraction sample manipulation procedures; and mostly label-based complex detection approaches. Here, we report on a point-of-care (POC) diagnosis paradigm based on the application of intradermal finger prick-based electronic nanosensors arrays for protein biomarkers' direct detection and quantification down to the sub-pM range, without the need for blood extraction and sample manipulation steps. The nanobioelectronic array performs biomarker sensing by a rapid intradermal prick-based sampling of proteins biomarkers directly from the capillary blood pool accumulating at the site of the microneedle puncture, requiring only 2 min and less than one microliter of a blood sample for a complete analysis. A 1 mm long microneedle element was optimal in allowing for pain-free dermal sampling with a 100% success rate of reaching and rupturing dermis capillaries. Current common micromachining processes and top-down fabrication techniques allow the nanobioelectronic sensor arrays to provide accurate and reliable clinical diagnostic results using multiple sensing elements in each microneedle and all-in-one direct and label-free multiplex biomarkers detection. Preliminary successful clinical studies performed on human volunteers demonstrated the ability of our intradermal, in-skin, blood extraction-free detection platform to accurately detect protein biomarkers as a plausible POC detection for future replacement of today's invasive clinical blood tests. This approach can be readily extended in the future to detect other clinically relevant circulating biomarkers, such as miRNAs, free-DNAs, exosomes, and small metabolites.
Collapse
Affiliation(s)
- Nimrod Harpak
- School
of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv69978, Israel
| | - Ella Borberg
- School
of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv69978, Israel
| | - Adva Raz
- Department
of Materials Science and Engineering, the Iby and Aladar Fleischman
Faculty of Engineering, Tel Aviv University, Tel Aviv69978, Israel
| | - Fernando Patolsky
- School
of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv69978, Israel
- Department
of Materials Science and Engineering, the Iby and Aladar Fleischman
Faculty of Engineering, Tel Aviv University, Tel Aviv69978, Israel
| |
Collapse
|
4
|
Ahmad Najib M, Selvam K, Khalid MF, Ozsoz M, Aziah I. Quantum Dot-Based Lateral Flow Immunoassay as Point-of-Care Testing for Infectious Diseases: A Narrative Review of Its Principle and Performance. Diagnostics (Basel) 2022; 12:diagnostics12092158. [PMID: 36140559 PMCID: PMC9497919 DOI: 10.3390/diagnostics12092158] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 08/25/2022] [Accepted: 08/31/2022] [Indexed: 11/16/2022] Open
Abstract
Infectious diseases are the world’s greatest killers, accounting for millions of deaths worldwide annually, especially in low-income countries. As the risk of emerging infectious diseases is increasing, it is critical to rapidly diagnose infections in the early stages and prevent further transmission. However, current detection strategies are time-consuming and have exhibited low sensitivity. Numerous studies revealed the advantages of point-of-care testing, such as those which are rapid, user-friendly and have high sensitivity and specificity, and can be performed at a patient’s bedside. The Lateral Flow Immunoassay (LFIA) is the most popular diagnostic assay that fulfills the POCT standards. However, conventional AuNPs-LFIAs are moderately sensitive, meaning that rapid detection remains a challenge. Here, we review quantum dot (QDs)-based LFIA for highly sensitive rapid diagnosis of infectious diseases. We briefly describe the principles of LFIA, strategies for applying QDs to enhance sensitivity, and the published performance of the QD-LFIA tested against several infectious diseases.
Collapse
Affiliation(s)
- Mohamad Ahmad Najib
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia
| | - Kasturi Selvam
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia
| | - Muhammad Fazli Khalid
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia
| | - Mehmet Ozsoz
- Department of Biomedical Engineering, Near East University, via Mersin 10, Nicosia 99138, Turkey
| | - Ismail Aziah
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia
- Correspondence:
| |
Collapse
|
5
|
Baker AN, Hawker-Bond GW, Georgiou PG, Dedola S, Field RA, Gibson MI. Glycosylated gold nanoparticles in point of care diagnostics: from aggregation to lateral flow. Chem Soc Rev 2022; 51:7238-7259. [PMID: 35894819 PMCID: PMC9377422 DOI: 10.1039/d2cs00267a] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Current point-of-care lateral flow immunoassays, such as the home pregnancy test, rely on proteins as detection units (e.g. antibodies) to sense for analytes. Glycans play a fundamental role in biological signalling and recognition events such as pathogen adhesion and hence they are promising future alternatives to antibody-based biosensing and diagnostics. Here we introduce the potential of glycans coupled to gold nanoparticles as recognition agents for lateral flow diagnostics. We first introduce the concept of lateral flow, including a case study of lateral flow use in the field compared to other diagnostic tools. We then introduce glycosylated materials, the affinity gains achieved by the cluster glycoside effect and the current use of these in aggregation based assays. Finally, the potential role of glycans in lateral flow are explained, and examples of their successful use given. Antibody-based lateral flow (immune) assays are well established, but here the emerging concept and potential of using glycans as the detection agents is reviewed.![]()
Collapse
Affiliation(s)
- Alexander N Baker
- Department of Chemistry, University of Warwick, Gibbet Hill Road, CV4 7AL, Coventry, UK.
| | - George W Hawker-Bond
- Oxford University Clinical Academic Graduate School, John Radcliffe Hospital Oxford, Oxford, OX3 9DU, UK
| | - Panagiotis G Georgiou
- Department of Chemistry, University of Warwick, Gibbet Hill Road, CV4 7AL, Coventry, UK.
| | | | - Robert A Field
- Iceni Glycoscience Ltd, Norwich, NR4 7GJ, UK.,Department of Chemistry and Manchester Institute of Biotechnology, University of Manchester, Manchester M1 7DN, UK
| | - Matthew I Gibson
- Department of Chemistry, University of Warwick, Gibbet Hill Road, CV4 7AL, Coventry, UK. .,Division of Biomedical Sciences, Warwick Medical School, University of Warwick, Gibbet Hill Road, CV4 7AL, Coventry, UK
| |
Collapse
|
6
|
Gao X, Boryczka J, Kasani S, Wu N. Enabling Direct Protein Detection in a Drop of Whole Blood with an "On-Strip" Plasma Separation Unit in a Paper-Based Lateral Flow Strip. Anal Chem 2020; 93:1326-1332. [PMID: 33347264 DOI: 10.1021/acs.analchem.0c02555] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Conventional paper lateral flow assays have low sensitivity and suffer from severe interference from complex human fluid sample matrices, which prevents their practical application in the testing of whole blood samples in the point-of-care settings. To solve this problem, gold nanostar@Raman reporter@silica-sandwiched nanoparticles have been developed as the surface-enhanced Raman scattering (SERS) probes for sensing transduction; and a functionalized filter membrane assembly has been designed and constructed in the paper-based lateral flow strip (PLFS) as a built-in plasma separation unit. In this "on-strip" plasma separation unit, three layers of filter membranes are stacked and surface-modified to maximize the separation efficiency and the plasma yield. As a result, the integrated PLFS has been successfully used for the detection of carcinoembryonic antigen (CEA) in 30 μL of whole blood with the assistance of a portable Raman reader, achieving a limit of detection of 1.0 ng mL-1. In short, this report presents an inexpensive, disposable, portable, and field-deployable paper-based device as a general point-of-care testing tool for protein biomarker detection in a drop of whole blood.
Collapse
Affiliation(s)
- Xuefei Gao
- Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, West Virginia 26506-6106, United States
| | - Jennifer Boryczka
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003-9303, United States
| | - Sujan Kasani
- Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, West Virginia 26506-6106, United States
| | - Nianqiang Wu
- Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, West Virginia 26506-6106, United States.,Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003-9303, United States
| |
Collapse
|
7
|
Lindquist HDA. Microbial biosensors for recreational and source waters. J Microbiol Methods 2020; 177:106059. [PMID: 32946871 DOI: 10.1016/j.mimet.2020.106059] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 09/13/2020] [Accepted: 09/13/2020] [Indexed: 12/21/2022]
Abstract
Biosensors are finding new places in science, and the growth of this technology will lead to dramatic improvements in the ability to detect microorganisms in recreational and source waters for the protection of public health. Much of the improvement in biosensors has followed developments in molecular biology processes and coupling these with advances in engineering. Progress in the fields of nano-engineering and materials science have opened many new avenues for biosensors. The adaptation of these diverse technological fields into sensors has been driven by the need to develop more rapid sensors that are highly accurate, sensitive and specific, and have other desirable properties, such as robust deployment capability, unattended operations, and remote data transfer. The primary challenges to the adoption of biosensors in recreational and source water applications are cost of ownership, particularly operations and maintenance costs, problems caused by false positive rates, and to a lesser extent false negative rates, legacy technologies, policies and practices which will change as biosensors improve to the point of replacing more traditional methods for detecting organisms in environmental samples.
Collapse
Affiliation(s)
- H D Alan Lindquist
- USEPA, 26 W. M.L. King DR., Cincinnati, OH 45268, United States of America.
| |
Collapse
|
8
|
Plaut RD, Staab AB, Munson MA, Gebhardt JS, Klimko CP, Quirk AV, Cote CK, Buhr TL, Rossmaier RD, Bernhards RC, Love CE, Berk KL, Abshire TG, Rozak DA, Beck LC, Stibitz S, Goodwin BG, Smith MA, Sozhamannan S. Avirulent Bacillus anthracis Strain with Molecular Assay Targets as Surrogate for Irradiation-Inactivated Virulent Spores. Emerg Infect Dis 2018; 24. [PMID: 29553922 PMCID: PMC5875273 DOI: 10.3201/eid2404.171646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
The revelation in May 2015 of the shipment of γ irradiation–inactivated wild-type Bacillus anthracis spore preparations containing a small number of live spores raised concern about the safety and security of these materials. The finding also raised doubts about the validity of the protocols and procedures used to prepare them. Such inactivated reference materials were used as positive controls in assays to detect suspected B. anthracis in samples because live agent cannot be shipped for use in field settings, in improvement of currently deployed detection methods or development of new methods, or for quality assurance and training activities. Hence, risk-mitigated B. anthracis strains are needed to fulfill these requirements. We constructed a genetically inactivated or attenuated strain containing relevant molecular assay targets and tested to compare assay performance using this strain to the historical data obtained using irradiation-inactivated virulent spores.
Collapse
|
9
|
Zhang Y, Xiao W, Kong H, Cheng J, Yan X, Zhang M, Wang Q, Qu H, Zhao Y. A Highly Sensitive Immunochromatographic Strip Test for Rapid and Quantitative Detection of Saikosaponin d. Molecules 2018; 23:molecules23020338. [PMID: 29415494 PMCID: PMC6017486 DOI: 10.3390/molecules23020338] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Revised: 01/23/2018] [Accepted: 02/01/2018] [Indexed: 01/13/2023] Open
Abstract
A quantitative lateral-flow immunoassay using gold nanoparticles (AuNPs) conjugated with a monoclonal antibody (MAb) against saikosaponin d (SSd) was developed for the analysis of SSd. The AuNPs were prepared in our laboratory. The AuNPs were polyhedral, with an average diameter of approximately 18 nm. We used the conjugation between AuNPs and MAbs against SSd to prepare immunochromatographic strips (ICSs). For the quantitative experiment, the strips with the test results were scanned using a membrane strip reader, and a detection curve (regression equation, y = -0.113ln(x) + 1.5451, R² = 0.983), representing the averages of the scanned data, was obtained. This curve was linear from 96 ng/mL to 150 μg/mL, and the IC50 value was 10.39 μg/mL. In this study, we bring the concept ofPOCT (point-of-care testing) to the measurement of TCM compounds, and this is the first report of quantitative detection of SSd by an ICS.
Collapse
Affiliation(s)
- Yue Zhang
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 100029, China.
| | - Wei Xiao
- Jiangsu Kanion Pharmaceutical Co., Ltd., 58 Jiangning Industrial Park Kangyuan Road, Lianyungang, Jiangsu, 210000, China.
| | - Hui Kong
- School of Basic Medical Sciences, Beijing University of Chinese Medicine, 11 Beisanhuandong Road, Chaoyang District, Beijing 100029, China.
| | - Jinjun Cheng
- School of Basic Medical Sciences, Beijing University of Chinese Medicine, 11 Beisanhuandong Road, Chaoyang District, Beijing 100029, China.
| | - Xin Yan
- School of Basic Medical Sciences, Beijing University of Chinese Medicine, 11 Beisanhuandong Road, Chaoyang District, Beijing 100029, China.
| | - Meiling Zhang
- School of Basic Medical Sciences, Beijing University of Chinese Medicine, 11 Beisanhuandong Road, Chaoyang District, Beijing 100029, China.
| | - Qingguo Wang
- School of Basic Medical Sciences, Beijing University of Chinese Medicine, 11 Beisanhuandong Road, Chaoyang District, Beijing 100029, China.
| | - Huihua Qu
- Centre of Scientific Experiment, Beijing University of Chinese Medicine, 11 Beisanhuandong Road, Chaoyang District, Beijing 100029, China.
| | - Yan Zhao
- School of Basic Medical Sciences, Beijing University of Chinese Medicine, 11 Beisanhuandong Road, Chaoyang District, Beijing 100029, China.
| |
Collapse
|
10
|
Banerjee R, Jaiswal A. Recent advances in nanoparticle-based lateral flow immunoassay as a point-of-care diagnostic tool for infectious agents and diseases. Analyst 2018; 143:1970-1996. [DOI: 10.1039/c8an00307f] [Citation(s) in RCA: 157] [Impact Index Per Article: 26.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Recent advances in lateral flow immunoassay-based devices as a point-of-care analytical tool for the detection of infectious diseases are reviewed.
Collapse
Affiliation(s)
- Ruptanu Banerjee
- School of Basic Sciences
- Indian Institute of Technology Mandi
- Mandi-175005
- India
| | - Amit Jaiswal
- School of Basic Sciences
- Indian Institute of Technology Mandi
- Mandi-175005
- India
| |
Collapse
|
11
|
Ibrahim HM, Sayed RH, Abdel-Aziz WR, Soliman RT. Preparation and evaluation of Salmonella Enteritidis antigen conjugated with nanogold for screening of poultry flocks. Vet World 2017; 10:848-853. [PMID: 28919672 PMCID: PMC5591467 DOI: 10.14202/vetworld.2017.848-853] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2017] [Accepted: 06/22/2017] [Indexed: 12/02/2022] Open
Abstract
Aim: The present work aimed to develop lateral flow immunochromatographic strip (ICS) test for detection of Salmonella Enteritidis (SE) specific antibodies in chicken sera. Materials and Methods: A rapid lateral flow immunochromatographic test (LFIT) has been developed, in which SE Group D antigen labeled with the gold chloride molecules laid on the conjugate pad. Staphylococcus aureus protein A was used as capture antibody at the test line (T) of a nitrocellulose (NC) membrane and anti-SE antigen-specific rabbit antibodies were used as capture antibody at the control line (C) of the NC strip in the lateral flow layout device. Results: Using the developed LFIT, the minimal amount of SE-specific antibodies that can be detected in chicken serum sample was 1427 enzyme-linked immunosorbent assay (ELISA) unit/100 µl that was equal to 0.1 µg (Ab)/100 µl sample. 100 suspected serum samples collected from a poultry flock were tested with the prepared SE-LFIT kits and the locally prepared stained Salmonella antigen, and the results were compared with those obtained from examination of these samples with Salmonella Group D antibody ELISA kit as the gold standard test. The sensitivity, specificity, and accuracy of the prepared SE-LFIT antigen kits were 94.4%, 90%, and 94%, respectively, while those obtained with stained Salmonella antigen were 88.8%, 90%, and 89%, respectively. Conclusion: The developed test is a simple field rapid test of high sensitivity, specificity, and accuracy that can improve and facilitates rapid field surveillance of salmonellosis among chickens.
Collapse
Affiliation(s)
- Hazem Mohammed Ibrahim
- Department of Bacterial Sera and Antigen Research, Veterinary Serum and Vaccine Research Institute, Abbasia, Cairo
| | - Rafik Hamed Sayed
- Central Laboratory for Evaluation of Veterinary Biologics, Abbasia, Cairo
| | - Wafaa Ragab Abdel-Aziz
- Department of Bacterial Sera and Antigen Research, Veterinary Serum and Vaccine Research Institute, Abbasia, Cairo
| | - Rafik Tawfik Soliman
- Department of Microbiology, Faculty of Veterinary Medicine, Cairo University, Cairo, Egypt
| |
Collapse
|
12
|
Rapid detection of fumonisin B1 using a colloidal gold immunoassay strip test in corn samples. Toxicon 2015; 108:210-5. [DOI: 10.1016/j.toxicon.2015.10.014] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2015] [Revised: 10/16/2015] [Accepted: 10/20/2015] [Indexed: 11/23/2022]
|
13
|
Self-assembled micro-structured sensors for food safety in paper based food packaging. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 53:331-5. [DOI: 10.1016/j.msec.2015.04.020] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2014] [Revised: 01/10/2015] [Accepted: 04/21/2015] [Indexed: 11/21/2022]
|
14
|
Advances in Anthrax Detection: Overview of Bioprobes and Biosensors. Appl Biochem Biotechnol 2015; 176:957-77. [PMID: 25987133 DOI: 10.1007/s12010-015-1625-z] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2014] [Accepted: 04/08/2015] [Indexed: 12/22/2022]
Abstract
Anthrax is an infectious disease caused by Bacillus anthracis. Although anthrax commonly affects domestic and wild animals, it causes a rare but lethal infection in humans. A variety of techniques have been introduced and evaluated to detect anthrax using cultures, polymerase chain reaction, and immunoassays to address the potential threat of anthrax being used as a bioweapon. The high-potential harm of anthrax in bioterrorism requires sensitive and specific detection systems that are rapid, field-ready, and real-time monitoring. Here, we provide a systematic overview of anthrax detection probes with their potential applications in various ultra-sensitive diagnostic systems.
Collapse
|
15
|
Goel AK. Anthrax: A disease of biowarfare and public health importance. World J Clin Cases 2015; 3:20-33. [PMID: 25610847 PMCID: PMC4295216 DOI: 10.12998/wjcc.v3.i1.20] [Citation(s) in RCA: 134] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Revised: 10/23/2014] [Accepted: 10/31/2014] [Indexed: 02/05/2023] Open
Abstract
Bioterrorism has received a lot of attention in the first decade of this century. Biological agents are considered attractive weapons for bioterrorism as these are easy to obtain, comparatively inexpensive to produce and exhibit widespread fear and panic than the actual potential of physical damage. Bacillus anthracis (B. anthracis), the etiologic agent of anthrax is a Gram positive, spore forming, non-motile bacterium. This is supposed to be one of the most potent BW agents because its spores are extremely resistant to natural conditions and can survive for several decades in the environment. B. anthracis spores enter the body through skin lesion (cutaneous anthrax), lungs (pulmonary anthrax), or gastrointestinal route (gastrointestinal anthrax) and germinate, giving rise to the vegetative form. Anthrax is a concern of public health also in many countries where agriculture is the main source of income including India. Anthrax has been associated with human history for a very long time and regained its popularity after Sept 2001 incidence in United States. The present review article describes the history, biology, life cycle, pathogenicity, virulence, epidemiology and potential of B. anthracis as biological weapon.
Collapse
|
16
|
A rapid lateral flow immunoassay for the detection of tyrosine phosphatase-like protein IA-2 autoantibodies in human serum. PLoS One 2014; 9:e103088. [PMID: 25047039 PMCID: PMC4105419 DOI: 10.1371/journal.pone.0103088] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Accepted: 06/27/2014] [Indexed: 12/20/2022] Open
Abstract
Type 1 diabetes (T1D) results from the destruction of pancreatic insulin-producing beta cells and is strongly associated with the presence of islet autoantibodies. Autoantibodies to tyrosine phosphatase-like protein IA-2 (IA-2As) are considered to be highly predictive markers of T1D. We developed a novel lateral flow immunoassay (LFIA) based on a bridging format for the rapid detection of IA-2As in human serum samples. In this assay, one site of the IA-2As is bound to HA-tagged-IA-2, which is subsequently captured on the anti-HA-Tag antibody-coated test line on the strip. The other site of the IA-2As is bound to biotinylated IA-2, allowing the complex to be visualized using colloidal gold nanoparticle-conjugated streptavidin. For this study, 35 serum samples from T1D patients and 44 control sera from non-diabetic individuals were analyzed with our novel assay and the results were correlated with two IA-2A ELISAs. Among the 35 serum samples from T1D patients, the IA-2A LFIA, the in-house IA-2A ELISA and the commercial IA-2A ELISA identified as positive 21, 29 and 30 IA-2A-positive sera, respectively. The major advantages of the IA-2A LFIA are its rapidity and simplicity.
Collapse
|
17
|
Austin LA, Mackey MA, Dreaden EC, El-Sayed MA. The optical, photothermal, and facile surface chemical properties of gold and silver nanoparticles in biodiagnostics, therapy, and drug delivery. Arch Toxicol 2014; 88:1391-417. [PMID: 24894431 PMCID: PMC4136654 DOI: 10.1007/s00204-014-1245-3] [Citation(s) in RCA: 243] [Impact Index Per Article: 24.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2014] [Accepted: 04/15/2014] [Indexed: 02/04/2023]
Abstract
Nanotechnology is a rapidly growing area of research in part due to its integration into many biomedical applications. Within nanotechnology, gold and silver nanostructures are some of the most heavily utilized nanomaterial due to their unique optical, photothermal, and facile surface chemical properties. In this review, common colloid synthesis methods and biofunctionalization strategies of gold and silver nanostructures are highlighted. Their unique properties are also discussed in terms of their use in biodiagnostic, imaging, therapeutic, and drug delivery applications. Furthermore, relevant clinical applications utilizing gold and silver nanostructures are also presented. We also provide a table with reviews covering related topics.
Collapse
Affiliation(s)
- Lauren A. Austin
- Laser Dynamics Laboratory, Department of Chemistry and Biochemistry, Georgia Institute of Technology, 901 Atlantic Dr. NW, Atlanta, GA 30332-0400, USA
| | - Megan A. Mackey
- Laser Dynamics Laboratory, Department of Chemistry and Biochemistry, Georgia Institute of Technology, 901 Atlantic Dr. NW, Atlanta, GA 30332-0400, USA
| | - Erik C. Dreaden
- Koch Institute for Integrative cancer Research, Department of chemical engineering, Massachusetts Institute of Technology, 500 Main St., Cambridge, MA 02139, USA
| | - Mostafa A. El-Sayed
- Laser Dynamics Laboratory, Department of Chemistry and Biochemistry, Georgia Institute of Technology, 901 Atlantic Dr. NW, Atlanta, GA 30332-0400, USA
| |
Collapse
|
18
|
Ferrari A, Friedrich A, Weill F, Wolman F, Leoni J. ANTIBODY LABELING WITH REMAZOL BRILLIANT VIOLET 5R, A VINYLSULPHONIC REACTIVE DYE. J Immunoassay Immunochem 2013; 34:323-32. [DOI: 10.1080/15321819.2012.732170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
19
|
Chen K, Zhao K, Song D, He W, Gao W, Zhao C, Wang C, Gao F. Development and evaluation of an immunochromatographic strip for rapid detection of porcine hemagglutinating encephalomyelitis virus. Virol J 2012; 9:172. [PMID: 22920192 PMCID: PMC3508965 DOI: 10.1186/1743-422x-9-172] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2011] [Accepted: 08/20/2012] [Indexed: 11/24/2022] Open
Abstract
Background The incidence of PHE among pigs in many countries is on the rise, and it has caused great economic losses to the pig industry. Therefore, the development of a sensitive, specific, and easily-performed assay is crucial for the rapid detection and surveillance of PHE-CoV infection and transmission. Results An immunochromatographic strip was developed for the detection of PHE-CoV. The colloidal gold-labeled MAb 4D4 was used as the detection reagent, and the MAb 1E2 and goat anti-mouse IgG coated the strip's test and control lines, respectively. The immunochromatographic strip was capable of specifically detecting PHE-CoV with a HA unit of 2 within 10 min. Storage of the strips at room temperature for 6 months or at 4°C for 12 months did not change their sensitivity or specificity. Using RT-PCR as a reference test, the relative specificity and sensitivity of the immunochromatographic strip were determined to be 100% and 97.78%, respectively. There was an excellent agreement between the results obtained by RT-PCR and the immunochromatographic strips (kappa = 0.976). Additionally, there was a strong agreement between the sandwich enzyme-linked immunosorbent assay (ELISA) and immunochromatographic strips (Kappa = 0.976). When the immunochromatographic strips were used for diagnosing PHE-CoV infection in the Jilin Province, the PHE-CoV-positive rate ranged from 61.54% in the Jilin district to 17.95% in the Songyuan district. Conclusions Based on its high specificity, sensitivity, and stability, the immunochromatographic strip would be suitable for on-site detection of PHE-CoV for surveillance and epidemiological purposes.
Collapse
Affiliation(s)
- Keyan Chen
- College of Animal Science and Veterinary Medicine, Jilin University, Changchun, China
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Dreaden EC, Alkilany AM, Huang X, Murphy CJ, El-Sayed MA. The golden age: gold nanoparticles for biomedicine. Chem Soc Rev 2012; 41:2740-79. [PMID: 22109657 PMCID: PMC5876014 DOI: 10.1039/c1cs15237h] [Citation(s) in RCA: 2013] [Impact Index Per Article: 167.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Gold nanoparticles have been used in biomedical applications since their first colloidal syntheses more than three centuries ago. However, over the past two decades, their beautiful colors and unique electronic properties have also attracted tremendous attention due to their historical applications in art and ancient medicine and current applications in enhanced optoelectronics and photovoltaics. In spite of their modest alchemical beginnings, gold nanoparticles exhibit physical properties that are truly different from both small molecules and bulk materials, as well as from other nanoscale particles. Their unique combination of properties is just beginning to be fully realized in range of medical diagnostic and therapeutic applications. This critical review will provide insights into the design, synthesis, functionalization, and applications of these artificial molecules in biomedicine and discuss their tailored interactions with biological systems to achieve improved patient health. Further, we provide a survey of the rapidly expanding body of literature on this topic and argue that gold nanotechnology-enabled biomedicine is not simply an act of 'gilding the (nanomedicinal) lily', but that a new 'Golden Age' of biomedical nanotechnology is truly upon us. Moving forward, the most challenging nanoscience ahead of us will be to find new chemical and physical methods of functionalizing gold nanoparticles with compounds that can promote efficient binding, clearance, and biocompatibility and to assess their safety to other biological systems and their long-term term effects on human health and reproduction (472 references).
Collapse
Affiliation(s)
- Erik C. Dreaden
- Laser Dynamics Laboratory, Department of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, GA 30332-0400, USA
| | - Alaaldin M. Alkilany
- Department of Pharmacology and Toxicology, Georgia Health Sciences University, 1459 Laney Walker Blvd., Augusta, GA 30912, USA
| | - Xiaohua Huang
- Department of Chemistry, University of Memphis, 213 Smith Chemistry Bldg, Memphis, TN 38152-3550, USA
| | - Catherine J. Murphy
- Department of Chemistry, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, IL 61801, USA. E-mail: ; Fax: +1 217 244 3186; Tel: +1 217 333 7680
| | - Mostafa A. El-Sayed
- Laser Dynamics Laboratory, Department of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, GA 30332-0400, USA
| |
Collapse
|
21
|
Biosensors Based on Nanoparticles and Electrochemical Detection. ACTA ACUST UNITED AC 2012. [DOI: 10.1016/b978-0-12-415769-9.00010-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/13/2023]
|
22
|
Wu H, Liu S, Jiang J, Shen G, Yu R. A novel electrochemical biosensor for highly selective detection of protease biomarker from Bacillus licheniformis with d-amino acid containing peptide. Analyst 2012; 137:4829-33. [DOI: 10.1039/c2an36066g] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
23
|
Addanki KC, Sheraz M, Knight K, Williams K, Pace DG, Bagasra O. Detection of anthrax toxin genetic sequences by the solid phase oligo-probes. Indian J Med Microbiol 2011; 29:372-8. [DOI: 10.4103/0255-0857.90169] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
24
|
Chen K, He W, Lu H, Song D, Gao W, Lan Y, Zhao K, Gao F. Development of an Immunochromatographic Strip for Serological Diagnosis of Porcine Hemagglutinating Encephalomyelitis Virus. J Vet Diagn Invest 2011; 23:288-96. [DOI: 10.1177/104063871102300214] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
An immunochromatographic strip was developed for the detection of an antibody against Porcine hemagglutinating encephalomyelitis virus (PHEV). Colloidal gold–labeled rabbit anti-pig immunoglobulin G (IgG) was used as the detection reagent, and the PHEV recombinant antigens and goat anti-rabbit IgG were coated on the prototype strip and the control lines, respectively. The immunochromatographic strip was capable of specifically detecting PHEV antibodies in serum with a hemagglutination inhibition (HI) titer of 2 within 10 min. Storage of the strips at room temperature for 6 months or at 4°C for 12 months did not change their sensitivity and specificity. Using HI as a reference test, the relative specificity and sensitivity of the immunochromatographic strip were determined to be 93.41% and 98.42%, respectively. There was a strong agreement between the results obtained by HI and the immunochromatographic strips (κ = 0.926). Additionally, there was a strong agreement between enzyme-linked immunosorbent assay and immunochromatographic strips (κ = 0.929). When the immunochromatographic strip was used for serological diagnosis of 1,117 serum samples in Jilin Province in China, the seropositivity ranged from 6.5% in the Liaoyuan District to 81.6% in the Changchun District. Furthermore, many piglets were seropositive to PHEV, indicating the possible transfer of maternal antibodies via the colostrum. Based on the high specificity, sensitivity, and stability of the immunochromatographic strip, it would be suitable for on-site detection of PHEV antibodies in order to monitor PHEV infections in an animal population.
Collapse
Affiliation(s)
- Keyan Chen
- College of Animal Science and Veterinary Medicine Jilin University, Changchun, People's Republic of China
| | - Wenqi He
- College of Animal Science and Veterinary Medicine Jilin University, Changchun, People's Republic of China
| | - Huijun Lu
- Key Laboratory of Zoonosis, Ministry of Education, Institute of Zoonosis and Animal Research Center Jilin University, Changchun, People's Republic of China
| | - Deguang Song
- College of Animal Science and Veterinary Medicine Jilin University, Changchun, People's Republic of China
| | - Wei Gao
- College of Animal Science and Veterinary Medicine Jilin University, Changchun, People's Republic of China
| | - Yungang Lan
- College of Animal Science and Veterinary Medicine Jilin University, Changchun, People's Republic of China
| | - Kui Zhao
- College of Animal Science and Veterinary Medicine Jilin University, Changchun, People's Republic of China
| | - Feng Gao
- College of Animal Science and Veterinary Medicine Jilin University, Changchun, People's Republic of China
| |
Collapse
|
25
|
Identification of Brucella abortus genes in elk (Cervus elaphus) using in vivo-induced antigen technology (IVIAT) reveals novel markers of infection. Vet Microbiol 2010; 142:367-72. [DOI: 10.1016/j.vetmic.2009.10.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2009] [Revised: 10/12/2009] [Accepted: 10/13/2009] [Indexed: 01/11/2023]
|
26
|
Kim J, Yoon MY. Recent advances in rapid and ultrasensitive biosensors for infectious agents: lesson from Bacillus anthracis diagnostic sensors. Analyst 2010; 135:1182-90. [PMID: 20498871 DOI: 10.1039/c0an00030b] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Here, we review the cumulative efforts to develop rapid and ultrasensitive diagnostic systems, especially for the infectious agent, Bacillus anthracis, as a model system. This Minireview focuses on demonstrating the features of various probes for target molecule detection and recent methods of signal generation within the biosensors. Also, we discuss the possibility of using peptides as next-generation probe molecules.
Collapse
Affiliation(s)
- Joungmok Kim
- Department of Chemistry, Research Institute for Natural Sciences, Hanyang University, Seoul 133-791, Korea
| | | |
Collapse
|
27
|
Kaittanis C, Santra S, Perez JM. Emerging nanotechnology-based strategies for the identification of microbial pathogenesis. Adv Drug Deliv Rev 2010; 62:408-23. [PMID: 19914316 DOI: 10.1016/j.addr.2009.11.013] [Citation(s) in RCA: 149] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2009] [Accepted: 09/14/2009] [Indexed: 01/04/2023]
Abstract
Infectious diseases are still a major healthcare problem. From food intoxication and contaminated water, to hospital-acquired diseases and pandemics, infectious agents cause disease throughout the world. Despite advancements in pathogens' identification, some of the gold-standard diagnostic methods have limitations, including laborious sample preparation, bulky instrumentation and slow data readout. In addition, new field-deployable diagnostic modalities are urgently needed in first responder and point-of-care applications. Apart from compact, these sensors must be sensitive, specific, robust and fast, in order to facilitate detection of the pathogen even in remote rural areas. Considering these characteristics, researchers have utilized innovative approaches by employing the unique properties of nanomaterials in order to achieve detection of infectious agents, even in complex media like blood. From gold nanoparticles and their plasmonic shifts to iron oxide nanoparticles and changes in magnetic properties, detection of pathogens, toxins, antigens and nucleic acids has been achieved with impressive detection thresholds. Additionally, as bacteria become resistant to antibiotics, nanotechnology has achieved the rapid determination of bacterial drug susceptibility and resistance using novel methods, such as amperometry and magnetic relaxation. Overall, these promising results hint to the adoption of nanotechnology-based diagnostics for the diagnosis of infectious diseases in diverse settings throughout the globe, preventing epidemics and safeguarding human and economic wellness.
Collapse
|
28
|
Rong-Hwa S, Shiao-Shek T, Der-Jiang C, Yao-Wen H. Gold nanoparticle-based lateral flow assay for detection of staphylococcal enterotoxin B. Food Chem 2010. [DOI: 10.1016/j.foodchem.2009.04.106] [Citation(s) in RCA: 100] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
29
|
Porter R, Kabil A, Forstern C, Slevin C, Kouwenberg K, Szymanski M, Birch B. A Novel, Generic, Electroanalytical Immunoassay Format Utilising Silver Nano-Particles as a Bio-Label. J Immunoassay Immunochem 2009; 30:428-40. [DOI: 10.1080/15321810903188268] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
30
|
Fisher M, Atiya-Nasagi Y, Simon I, Gordin M, Mechaly A, Yitzhaki S. A combined immunomagnetic separation and lateral flow method for a sensitive on-site detection ofBacillus anthracisspores - assessment in water and dairy products. Lett Appl Microbiol 2009; 48:413-8. [DOI: 10.1111/j.1472-765x.2008.02542.x] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
31
|
Detection of anthrax toxin by an ultrasensitive immunoassay using europium nanoparticles. CLINICAL AND VACCINE IMMUNOLOGY : CVI 2009; 16:408-13. [PMID: 19129473 DOI: 10.1128/cvi.00412-08] [Citation(s) in RCA: 83] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
We developed a europium nanoparticle-based immunoassay (ENIA) for the sensitive detection of anthrax protective antigen (PA). The ENIA exhibited a linear dose-dependent pattern within the detection range of 0.01 to 100 ng/ml and was approximately 100-fold more sensitive than enzyme-linked immunosorbent assay (ELISA). False-positive results were not observed with serum samples from healthy adults, mouse plasma without PA, or plasma samples collected from mice injected with anthrax lethal factor or edema factor alone. For the detection of plasma samples spiked with PA, the detection sensitivities for ENIA and ELISA were 100% (11/11 samples) and 36.4% (4/11 samples), respectively. The assay exhibited a linear but qualitative correlation between the PA injected and the PA detected in murine blood (r=0.97731; P<0.0001). Anthrax PA was also detected in the circulation of mice infected with spores from a toxigenic Sterne-like strain of Bacillus anthracis, but only in the later stages of infection. These results indicate that the universal labeling technology based on europium nanoparticles and its application may provide a rapid and sensitive testing platform for clinical diagnosis and laboratory research.
Collapse
|
32
|
Liu HL, Sonn CH, Wu JH, Lee KM, Kim YK. Synthesis of streptavidin-FITC-conjugated core–shell Fe3O4-Au nanocrystals and their application for the purification of CD4+ lymphocytes. Biomaterials 2008; 29:4003-11. [DOI: 10.1016/j.biomaterials.2008.06.031] [Citation(s) in RCA: 81] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2008] [Accepted: 06/28/2008] [Indexed: 10/21/2022]
|
33
|
Expression of the capsid protein of Chikungunya virus in a baculovirus for serodiagnosis of Chikungunya disease. J Virol Methods 2008; 154:154-9. [PMID: 18761376 DOI: 10.1016/j.jviromet.2008.07.031] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2008] [Revised: 07/24/2008] [Accepted: 07/31/2008] [Indexed: 11/20/2022]
Abstract
Chikungunya virus (CHIKV) causes endemic or epidemic outbreaks of CHIK fever, which typically manifests as a febrile illness. To develop a CHIKV-specific diagnostic test, CHIKV capsid protein was expressed using a baculovirus expression system. The seroreactvity of the recombinant CHIKV capsid protein was evaluated by ELISA and immuochromatographic assay (ICA), using 40 anti-CHIKV-positive and 20 anti-CHIKV-negative sera, an additional 20 normal sera samples from healthy Koreans, and 20 anti-Dengue virus sera samples. The sensitivity of the recombinant CHIKV capsid protein was 85% and 87.5% as measured by ELISA and ICA, respectively. The specificity of the recombinant CHIKV capsid protein was 100% both by ELISA and by ICA. No cross-reactivity of the capsid protein was seen with anti-Dengue virus sera samples. There was a significant correlation between the ELISA- and ICA-measured seroreactivities of the recombinant CHIKV capsid protein for anti-CHIKV IgM-positive sera samples. These results suggest that the recombinant CHIKV capsid protein could be used in a diagnostic test for identifying CHIKV disease.
Collapse
|
34
|
Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey. Anal Bioanal Chem 2008; 393:569-82. [PMID: 18696055 DOI: 10.1007/s00216-008-2287-2] [Citation(s) in RCA: 947] [Impact Index Per Article: 59.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2008] [Revised: 07/01/2008] [Accepted: 07/03/2008] [Indexed: 10/21/2022]
Abstract
Lateral flow (immuno)assays are currently used for qualitative, semiquantitative and to some extent quantitative monitoring in resource-poor or non-laboratory environments. Applications include tests on pathogens, drugs, hormones and metabolites in biomedical, phytosanitary, veterinary, feed/food and environmental settings. We describe principles of current formats, applications, limitations and perspectives for quantitative monitoring. We illustrate the potentials and limitations of analysis with lateral flow (immuno)assays using a literature survey and a SWOT analysis (acronym for "strengths, weaknesses, opportunities, threats"). Articles referred to in this survey were searched for on MEDLINE, Scopus and in references of reviewed papers. Search terms included "immunochromatography", "sol particle immunoassay", "lateral flow immunoassay" and "dipstick assay".
Collapse
|
35
|
Rapid point-of-care test to detect broad ranges of protective antigen-specific immunoglobulin G concentrations in recipients of the U.S.-licensed anthrax vaccine. CLINICAL AND VACCINE IMMUNOLOGY : CVI 2008; 15:644-9. [PMID: 18321882 DOI: 10.1128/cvi.00473-07] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Currently, there is no routine monitoring of an immune response to the anthrax vaccine. Simple on-site tests are needed to evaluate the antibody response of anthrax-vaccinated individuals in the Armed Forces and others at high risk. Using a prototype lateral flow assay (LFA) (R. E. Biagini, D. L. Sammons, J. P. Smith, B. A. MacKenzie, C. A. F. Striley, J. E. Snawder, S. A. Robertson, and C. P. Quinn, Clin. Vaccine Immunol. 13:541-546, 2006), we investigated the agreement between a validated anthrax protective antigen (PA) immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) and the LFA for 335 unvaccinated and vaccinated subjects. We also investigated the performance of the LFA under the following conditions: thermal shock (i.e., thermal cycling between temperature extremes), high temperature/high relative humidity, high temperature/low relative humidity, and low temperature/low relative humidity. With the anti-PA ELISA used as a standard, the LFA was shown to be optimally diagnostic at 11 microg/ml anti-PA-specific IgG. At this concentration, the LFA specificity and sensitivity were 98% (95% confidence interval [CI], 97% to 100%) and 92% (CI, 88% to 97%), respectively. Receiver operating characteristic curve analysis yielded an area under the curve value of 0.988 (CI, 0.976 to 1.00), suggesting that the LFA is an extremely accurate diagnostic test. For < or = 4 or > or = 50 microg/ml PA-specific IgG, the LFA results for each environmental condition were identical to those obtained in the laboratory. These data indicate that this rapid point-of-care test would be a feasible tool in monitoring the serological antibody responses of individuals that have been vaccinated against anthrax.
Collapse
|
36
|
Ashley K, Biagini RE, Smith JP, Sammons DL, Mackenzie BA, Striley CAF, Robertson SK, Snawder JE. The use of immunochemical and biosensor methods for occupational and environmental monitoring. Part I: introduction to immunoassays. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2008; 5:D25-D32. [PMID: 18074291 DOI: 10.1080/15459620701798182] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Affiliation(s)
- Kevin Ashley
- Biomonitoring and Health Assessment Branch, Division of Applied Research and Technology, National Institute for Occupational Safety and Health, Centers for Disease Control andPrevention, Cincinnati, Ohio, USA
| | | | | | | | | | | | | | | |
Collapse
|
37
|
Nagy JO, Zhang Y, Yi W, Liu X, Motari E, Song JC, Lejeune JT, Wang PG. Glycopolydiacetylene nanoparticles as a chromatic biosensor to detect Shiga-like toxin producing Escherichia coli O157:H7. Bioorg Med Chem Lett 2007; 18:700-3. [PMID: 18086524 DOI: 10.1016/j.bmcl.2007.11.055] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2007] [Revised: 11/14/2007] [Accepted: 11/15/2007] [Indexed: 11/17/2022]
Abstract
Shiga toxin-producing Escherichia coli organisms (STEC) were detected by Gal-alpha1,4-Gal glycopolydiacetylene (GPDA) nanoparticles through the selective binding between Shiga toxin and GPDA nanoparticles. The binding produced a colorimetric change in the absorption wavelength of the GPDA nanoparticles. This method provides a highly selective, rapid, sensitive, and quantitative approach for the detection of STEC.
Collapse
Affiliation(s)
- Jon O Nagy
- ATERIS Technologies, Bozeman, MT 59718, USA.
| | | | | | | | | | | | | | | |
Collapse
|
38
|
Aslan K, Zhang Y, Hibbs S, Baillie L, Previte MJR, Geddes CD. Microwave-accelerated metal-enhanced fluorescence: application to detection of genomic and exosporium anthrax DNA in <30 seconds. Analyst 2007; 132:1130-8. [PMID: 17955147 DOI: 10.1039/b707876e] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We describe the ultra-fast and sensitive detection of the gene encoding the protective antigen of Bacillus anthracis the causative agent of anthrax. Our approach employs a highly novel platform technology, Microwave-Accelerated Metal-Enhanced Fluorescence (MAMEF), which combines the use of Metal-Enhanced Fluorescence to enhance assay sensitivity and focused microwave heating to spatially and kinetically accelerate DNA hybridization. Genomic and exosporium target DNA of Bacillus anthracis spores was detected within a minute in the nanograms per microliter concentration range using low-power focused microwave heating. The MAMEF technology was able to distinguish between B. anthracis and B. cereus, a non-virulent close relative. We believe that this study has set the stage and indeed provides an opportunity for the ultra-fast and specific detection of B. anthracis spores with minimal pre-processing steps using a relatively simple but cost-effective technology that could minimize casualties in the event of another anthrax attack.
Collapse
Affiliation(s)
- Kadir Aslan
- Institute of Fluorescence, Laboratory for Advanced Medical Plasmonics, Medical Biotechnology Center, University of Maryland Biotechnology Institute, Baltimore, MD 21201, USA
| | | | | | | | | | | |
Collapse
|
39
|
Bienek DR, Chang CK, Cohen ME. Detection of anti-protective antigen salivary IgG antibodies in recipients of the US licensed anthrax vaccine. Vaccine 2007; 25:5978-84. [PMID: 17597265 DOI: 10.1016/j.vaccine.2007.05.043] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2007] [Revised: 04/27/2007] [Accepted: 05/21/2007] [Indexed: 11/25/2022]
Abstract
The immune response of anthrax vaccine recipients is not routinely monitored. For field use, a noninvasive test would be beneficial to evaluate the antibody response of anthrax-vaccinated individuals working within a high-risk area of possible exposure. The aim of this cross-sectional study was to determine whether whole saliva can be used as a surrogate matrix for the detection of 83 kDa protective antigen (PA)-specific immunoglobulin G (IgG). An enzyme-linked immunosorbent assay was used for the detection of PA-specific IgG in matched samples (serum and saliva) that were collected from vaccinated and unvaccinated participants. Specimens from 180 individuals revealed a positive correlation (r=0.73; P<0.0001) between the level of PA-specific antibody detected in the saliva and serum. The number of vaccinations influenced both the saliva and serum antibody response. On average, the concentration of serological PA-specific antibodies in the vaccinated group was nearly 1600-fold greater than that in saliva. The magnitude of the salivary anti-PA antibody response was not significantly affected by the consumption of food, beverage, or tobacco products or other factors, which could potentially affect oral fluid properties. These results suggest that an oral fluid-based immunoassay may be a feasible alternative to monitoring the serological antibody response of individuals that have been vaccinated against anthrax.
Collapse
Affiliation(s)
- Diane R Bienek
- Naval Institute for Dental and Biomedical Research, Great Lakes, IL 60088-5259, United States.
| | | | | |
Collapse
|
40
|
Campanella L, Martini E, Tomassetti M. Immunochemical Potentiometric Method for HIgG and Anti‐HIgG Determination, Using a NH3Probe and Immunoprecipitation as Preconcentration Procedure. ANAL LETT 2007. [DOI: 10.1080/00032710600952473] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|