1
|
Moore SC, Park MA, Liu Z, Lyon MC, Johnson LC, Lushear VH, Westberg JG, Metzler SD. Design of a dual-resolution collimator for preclinical cardiac SPECT with a stationary triple-detector system. Med Phys 2016; 43:6336. [PMID: 27908172 PMCID: PMC5097051 DOI: 10.1118/1.4966697] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2016] [Revised: 08/17/2016] [Accepted: 10/11/2016] [Indexed: 11/07/2022] Open
Abstract
PURPOSE One approach to preclinical single-photon emission computed tomography (SPECT) imaging that provides both high resolution and high sensitivity is based on imaging a mouse inside a collimating tube; many magnified pinhole projection images from a small target region, e.g., the heart, can be recorded simultaneously on multiple detectors with little multiplexing since each pinhole aperture's opening angle is restricted to view mostly the target organ. However, to obtain complete data for reconstruction, it may be necessary to scan the mouse through the target region of the tube. The authors are developing a different approach based on acquisition and reconstruction of both low-resolution and high-resolution projection data acquired sequentially through many pinholes embedded in two tungsten tube sections of different diameters, a "scout" section and a high-resolution section, placed end-to-end along the axis of a triple-head clinical SPECT scanner. This paper describes the design procedures used to determine the geometric parameters of two new collimator-tube sections, as well as one approach for joint reconstruction of data acquired from both sections. METHODS The high-resolution section was designed by projecting as many pinhole views of a simulated mouse heart as possible over each detector's camera, with no overlapping of heart projections and minimal overlapping between adjacent "hot" organ and cardiac projections. The authors then jointly optimized the geometric design of the scout section for a triple-detector camera system, as well as the number of maximum-likelihood expectation maximization (MLEM) iterations required to provide minimum mean-squared error of reconstructed voxel counts throughout a 7-cm axial range, with the constraints of fixed, 2.4-mm scout system resolution at the tube center for all apertures, limited multiplexing, and no detector motion. Simulated mouse projection data from both tube sections were then reconstructed to illustrate a simple approach for using high-resolution data to improve the whole-body scout images within a cylindrical region surrounding the heart. RESULTS The 2-cm-inner-radius high-resolution tube section accommodated 87 platinum-iridium pinhole inserts, each with a 0.3-mm square aperture; their radial distances from the centerline of the system ranged from 2.2 to 3.0 cm. The optimal radial distance to the closest scout pinhole and optimal number of MLEM iterations were 4.4 cm and 35 iterations, respectively, and the radial distances of the 39 scout pinholes ranged from 4.4 to 4.8 cm; aperture sizes ranged from 1.1 to 1.7 mm transaxially and 0.9-1.5 mm axially. After including data from the high-resolution section viewing the heart region into whole-body mouse reconstructions from scout data, the authors obtained high-resolution images of the heart, embedded within lower resolution images of the body, with minimal artifacts. CONCLUSIONS The authors have optimized a dual-resolution collimator tube that provides both whole-body projections of a mouse and more targeted projections centered on the heart that can be jointly reconstructed to obtain high-resolution images of the heart embedded within lower-resolution whole-body images.
Collapse
Affiliation(s)
- Stephen C Moore
- Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts 02115
| | - Mi-Ae Park
- Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts 02115
| | - Zhe Liu
- Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts 02115
| | | | - Lindsay C Johnson
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104
| | | | | | - Scott D Metzler
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104
| |
Collapse
|
2
|
Abstract
In this chapter, we describe protocols for tumor imaging technologies in mouse models. These models utilize human cancer cell lines which have been genetically engineered to selectively express high levels of green fluorescent protein (GFP) or red fluorescent protein (RFP). Tumors with fluorescent genetic reporters are established subcutaneously in nude mice, and fragments of the subcutaneous tumors are then surgically transplanted onto the orthotopic organ. Locoregional tumor growth and distant metastasis of these orthotopic implants occur spontaneously and rapidly throughout the abdomen in a manner consistent with clinical human disease. Highly specific, high-resolution, real-time quantitative fluorescence imaging of tumor growth and metastasis may be achieved in vivo without the need for contrast agents, invasive techniques, or expensive imaging equipment. Transplantation of RFP-expressing tumor fragments onto the pancreas of GFP- or cyan fluorescent protein (CFP)-expressing transgenic nude mice was used to facilitate visualization of tumor-host interaction between the pancreatic cancer cells and host-derived stroma and vasculature. Such in vivo models have enabled us to visualize in real time and acquire images of the progression of pancreatic cancer in the live animal, and to demonstrate the real-time antitumor and antimetastatic effects of several novel therapeutic strategies on a variety of malignancies. We discuss studies from our laboratory that demonstrate that fluorescence imaging in mice is complementary to other modalities such as magnetic resonance imaging (MRI) or ultrasound. These fluorescent models are powerful and reliable tools with which to investigate metastatic human cancer and novel therapeutic strategies directed against it.
Collapse
|
3
|
Priem B, Tian C, Tang J, Zhao Y, Mulder WJM. Fluorescent nanoparticles for the accurate detection of drug delivery. Expert Opin Drug Deliv 2015; 12:1881-94. [PMID: 26292712 DOI: 10.1517/17425247.2015.1074567] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
INTRODUCTION The application of intravenously administered nanoparticle (NP) therapies is increasingly being explored for a variety of diseases. The key to their success lies in a thorough understanding of nanoparticle pharmacological behavior, specificity and elimination kinetics. Fluorescent imaging techniques provide exciting opportunities to gain insight into such NP behavior in complex biological systems, at macroscopic as well as microscopic levels. AREAS COVERED In this review, we will summarize NP labeling methods in relation to their established and emerging fluorescent imaging modalities for in vitro, in vivo, and ex vivo studies of NP behavior. We will highlight novel applications and discuss recent developments in techniques such as fluorescence molecular tomography (FMT), Förster resonance energy transfer (FRET), and Raman imaging. Finally, we will provide a perspective on the challenges and future directions of NP-based fluorescent labeling and imaging in nanotherapeutics. EXPERT OPINION Commonly used in preclinical applications, fluorescent imaging of NPs can be achieved with minimal invasiveness and low toxicity in a multiplex fashion. Increasingly applied in the study of NP biodistribution, dissociation, and elimination behavior, fluorescent imaging allows fluid longitudinal tracking and visualization of NP interactions at the level of the whole animal, target organs/tissues, and individual cells.
Collapse
Affiliation(s)
- Bram Priem
- a 1 Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai , New York, New York 10029, USA
| | - Cheng Tian
- a 1 Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai , New York, New York 10029, USA
| | - Jun Tang
- a 1 Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai , New York, New York 10029, USA
| | - Yiming Zhao
- a 1 Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai , New York, New York 10029, USA
| | - Willem J M Mulder
- a 1 Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai , New York, New York 10029, USA .,b 2 Department of Vascular Medicine, Academic Medical Center , Amsterdam 1105 AZ, The Netherlands
| |
Collapse
|
4
|
Spatial memory training induces morphological changes detected by manganese-enhanced MRI in the hippocampal CA3 mossy fiber terminal zone. Neuroimage 2015; 128:227-237. [PMID: 26254115 DOI: 10.1016/j.neuroimage.2015.07.084] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2014] [Revised: 07/22/2015] [Accepted: 07/30/2015] [Indexed: 01/03/2023] Open
Abstract
Hippocampal mossy fibers (MFs) can show plasticity of their axon terminal arbor consequent to learning a spatial memory task. Such plasticity is seen as translaminar sprouting from the stratum lucidum (SL) of CA3 into the stratum pyramidale (SP) and the stratum oriens (SO). However, the functional role of this presynaptic remodeling is still obscure. In vivo imaging that allows longitudinal observation of such remodeling could provide a deeper understanding of this presynaptic growth phenomenon as it occurs over time. Here we used manganese-enhanced magnetic resonance imaging (MEMRI), which shows a high-contrast area that co-localizes with the MFs. This technique was applied in the detection of learning-induced MF plasticity in two strains of rats. Quantitative analysis of a series of sections in the rostral dorsal hippocampus showed increases in the CA3a' area in MEMRI of trained Wistar rats consistent with the increased SO+SP area seen in the Timm's staining. MF plasticity was not seen in the trained Lister-Hooded rats in either MEMRI or in Timm's staining. This indicates the potential of MEMRI for revealing neuro-architectures and plasticity of the hippocampal MF system in vivo in longitudinal studies.
Collapse
|
5
|
Abstract
Pancreatic cancer is critical for developed countries, where its rate of diagnosis has been increasing steadily annually. In the past decade, the advances of pancreatic cancer research have not contributed to the decline in mortality rates from pancreatic cancer-the overall 5-year survival rate remains about 5% low. This number only underscores an obvious urgency for us to better understand the biological features of pancreatic carcinogenesis, to develop early detection methods, and to improve novel therapeutic treatments. To achieve these goals, animal modeling that faithfully recapitulates the whole process of human pancreatic cancer is central to making the advancements. In this review, we summarize the currently available animal models for pancreatic cancer and the advances in pancreatic cancer animal modeling. We compare and contrast the advantages and disadvantages of three major categories of these models: (1) carcinogen-induced; (2) xenograft and allograft; and (3) genetically engineered mouse models. We focus more on the genetically engineered mouse models, a category which has been rapidly expanded recently for their capacities to mimic human pancreatic cancer and metastasis, and highlight the combinations of these models with various newly developed strategies and cell-lineage labeling systems.
Collapse
Affiliation(s)
- Wanglong Qiu
- Department of Otolaryngology and Head and Neck Surgery, Columbia University Medical Center, 1130 St. Nicholas Ave, ICRC 10-04, New York, NY 10032, USA
- Herbert Irving Comprehensive Cancer Center, Columbia University Medical Center, New York, NY 10032, USA
| | - Gloria H. Su
- Department of Otolaryngology and Head and Neck Surgery, Columbia University Medical Center, 1130 St. Nicholas Ave, ICRC 10-04, New York, NY 10032, USA
- Department of Pathology, Columbia University Medical Center, New York, NY 10032, USA
- Herbert Irving Comprehensive Cancer Center, Columbia University Medical Center, New York, NY 10032, USA
| |
Collapse
|
6
|
Venugopal V, Intes X. Adaptive wide-field optical tomography. JOURNAL OF BIOMEDICAL OPTICS 2013; 18:036006. [PMID: 23475290 PMCID: PMC3591745 DOI: 10.1117/1.jbo.18.3.036006] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2012] [Revised: 02/02/2013] [Accepted: 02/05/2013] [Indexed: 05/20/2023]
Abstract
We describe a wide-field optical tomography technique, which allows the measurement-guided optimization of illumination patterns for enhanced reconstruction performances. The iterative optimization of the excitation pattern aims at reducing the dynamic range in photons transmitted through biological tissue. It increases the number of measurements collected with high photon counts resulting in a dataset with improved tomographic information. Herein, this imaging technique is applied to time-resolved fluorescence molecular tomography for preclinical studies. First, the merit of this approach is tested by in silico studies in a synthetic small animal model for typical illumination patterns. Second, the applicability of this approach in tomographic imaging is validated in vitro using a small animal phantom with two fluorescent capillaries occluded by a highly absorbing inclusion. The simulation study demonstrates an improvement of signal transmitted (∼2 orders of magnitude) through the central portion of the small animal model for all patterns considered. A corresponding improvement in the signal at the emission wavelength by 1.6 orders of magnitude demonstrates the applicability of this technique for fluorescence molecular tomography. The successful discrimination and localization (∼1 mm error) of the two objects with higher resolution using the optimized patterns compared with nonoptimized illumination establishes the improvement in reconstruction performance when using this technique.
Collapse
Affiliation(s)
- Vivek Venugopal
- Rensselaer Polytechnic Institute, Department of Biomedical Engineering, 110 8th Street, Troy, New York 12180
| | - Xavier Intes
- Rensselaer Polytechnic Institute, Department of Biomedical Engineering, 110 8th Street, Troy, New York 12180
- Address all correspondence to: Xavier Intes, Rensselaer Polytechnic Institute, Department of Biomedical Engineering, 110 8th Street, Troy, New York 12180. Tel: (518) 276-6964; E-mail:
| |
Collapse
|
7
|
Même S, Joudiou N, Szeremeta F, Mispelter J, Louat F, Decoville M, Locker D, Beloeil JC. In vivo magnetic resonance microscopy of Drosophilae at 9.4 T. Magn Reson Imaging 2012; 31:109-19. [PMID: 22898691 DOI: 10.1016/j.mri.2012.06.019] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2012] [Revised: 05/16/2012] [Accepted: 06/25/2012] [Indexed: 10/28/2022]
Abstract
In preclinical research, genetic studies have made considerable progress as a result of the development of transgenic animal models of human diseases. Consequently, there is now a need for higher resolution MRI to provide finer details for studies of small animals (rats, mice) or very small animals (insects). One way to address this issue is to work with high-magnetic-field spectrometers (dedicated to small animal imaging) with strong magnetic field gradients. It is also necessary to develop a complete methodology (transmit/receive coil, pulse sequence, fixing system, air supply, anesthesia capabilities, etc.). In this study, we developed noninvasive protocols, both in vitro and in vivo (from coil construction to image generation), for drosophila MRI at 9.4 T. The 10 10 80-μm resolution makes it possible to visualize whole drosophila (head, thorax, abdomen) and internal organs (ovaries, longitudinal and transverse muscles, bowel, proboscis, antennae and optical lobes). We also provide some results obtained with a Drosophila model of muscle degeneration. This opens the way for new applications of structural genetic modification studies using MRI of drosophila.
Collapse
Affiliation(s)
- Sandra Même
- Centre de Biophysique Moléculaire, CNRS UPR4301, Orléans, France.
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Chao KT, Tsao HH, Weng YH, Hsiao IT, Hsieh CJ, Wey SP, Yen TC, Kung MP, Lin KJ. Quantitative analysis of binding sites for 9-fluoropropyl-(+)-dihydrotetrabenazine ([18F]AV-133) in a MPTP-lesioned PD mouse model. Synapse 2012; 66:823-31. [DOI: 10.1002/syn.21572] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2012] [Accepted: 05/08/2012] [Indexed: 02/06/2023]
|
9
|
Effect of Animal Condition and Fluvoxamine on the Result of [(18)F]N-3-Fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl) Nortropane ([(18)F]FP-CIT) PET Study in Mice. Nucl Med Mol Imaging 2012; 46:27-33. [PMID: 24900029 DOI: 10.1007/s13139-011-0117-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2011] [Revised: 10/26/2011] [Accepted: 11/02/2011] [Indexed: 10/15/2022] Open
Abstract
PURPOSE PET (positron emission tomography) is a noninvasive imaging technique, visualizing biological aspects in vivo. In animal models, the result of PET study can be affected more prominently than in humans by the animal conditions or drug pretreatment. We assessed the effects of anesthesia, body temperature, and pretreatment with selective serotonin reuptake inhibitor on the results of [(18)F]N-3-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl) nortropane ([(18)F]FP-CIT) PET in mice. METHODS [(18)F]FP-CIT PET of C57BL/6 mice was performed in three different conditions: (1) anesthesia (isoflurane) with active warming (38°C) as a reference; (2) no anesthesia or warming; (3) anesthesia without warming at room temperature. Additional groups of mice pretreated with escalating doses of fluvoxamine (5, 20, 40, 80 mg/kg) were imaged in condition (1). The time activity curve and standardized uptake value of the striatum, cerebral cortex, and bone were compared among these conditions. RESULTS In all conditions, radioactivities of the striatum and cortex tended to form a plateau after rapid uptake and washout, but that of bone tended to increase gradually. When anesthetized without any warming, all the mice developed hypothermia and showed reduced bone uptake with slightly increased striatal and cortical uptakes compared to the reference condition. In conditions without anesthesia, striatal and cortical uptakes were reduced, whereas the bone uptake showed no change. Pretreatment with fluvoxamine increased the striatal uptake and striatal specific to cortical non-specific uptake ratio, whereas the bone uptake was reduced. CONCLUSION Anesthesia, body temperature, and fluvoxamine affect the result of [(18)F]FP-CIT PET in mice by altering striatal and bone uptakes.
Collapse
|
10
|
Gupta AA, Ding D, Lee RK, Levy RB, Bhattacharya SK. Spontaneous ocular and neurologic deficits in transgenic mouse models of multiple sclerosis and noninvasive investigative modalities: a review. Invest Ophthalmol Vis Sci 2012; 53:712-24. [PMID: 22331505 DOI: 10.1167/iovs.11-8351] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Multiple sclerosis (MS) is an autoimmune, inflammatory, neurodegenerative, demyelinating disease of the central nervous system, predominantly involving myelinated neurons of the brain, spinal cord, and optic nerve. Optic neuritis is frequently associated with MS and often precedes other neurologic deficits associated with MS. A large number of patients experience visual defects and have abnormalities concomitant with neurologic abnormalities. Transgenic mice manifesting spontaneous neurologic and ocular disease are unique models that have revolutionized the study of MS. Spontaneous experimental autoimmune encephalomyelitis (sEAE) presents with spontaneous onset of demyelination, without the need of an injectable immunogen. This review highlights the various models of sEAE, their disease characteristics, and applicability for future research. The study of optic neuropathy and neurologic manifestations of demyelination in sEAE will expand our understanding of the pathophysiological mechanisms underlying MS. Early and precise diagnosis of MS with different noninvasive methods has opened new avenues in managing symptoms, reducing morbidity, and limiting disease burden. This review discusses the spectrum of available noninvasive techniques, such as electrophysiological and behavioral assessment, optical coherence tomography, scanning laser polarimetry, confocal scanning laser ophthalmoscopy, pupillometry, magnetic resonance imaging, positron emission tomography, gait, and cardiovascular monitoring, and their clinical relevance.
Collapse
Affiliation(s)
- Archana A Gupta
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida 33136, USA
| | | | | | | | | |
Collapse
|
11
|
Mok SI, Munasinghe JP, Young WS. Infusion-based manganese-enhanced MRI: a new imaging technique to visualize the mouse brain. Brain Struct Funct 2012; 217:107-14. [PMID: 21597966 PMCID: PMC3242156 DOI: 10.1007/s00429-011-0324-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2011] [Accepted: 04/28/2011] [Indexed: 12/17/2022]
Abstract
Manganese-enhanced magnetic resonance imaging is a technique that employs the divalent ion of the paramagnetic metal manganese (Mn(2+)) as an effective contrast agent to visualize, in vivo, the mammalian brain. As total achievable contrast is directly proportional to the net amount of Mn(2+) accumulated in the brain, there is a great interest in optimizing administration protocols to increase the effective delivery of Mn(2+) to the brain while avoiding the toxic effects of Mn(2+) overexposure. In this study, we investigated outcomes following continuous slow systemic infusion of manganese chloride (MnCl(2)) into the mouse via mini-osmotic pump administration. The effects of increasing fractionated rates of Mn(2+) infusion on signal enhancement in regions of the brain were analyzed in a three-treatment study. We acquired whole-brain 3-D T1-weighted images and performed region of interest quantitative analysis to compare mean normalized signal in Mn(2+) treatments spanning 3, 7, or 14 days of infusion (rates of 1, 0.5, and 0.25 μL/h, respectively). Evidence of Mn(2+) transport at the conclusion of each infusion treatment was observed throughout the brains of normally behaving mice. Regions of particular Mn(2+) accumulation include the olfactory bulbs, cortex, infralimbic cortex, habenula, thalamus, hippocampal formation, amygdala, hypothalamus, inferior colliculus, and cerebellum. Signals measured at the completion of each infusion treatment indicate comparable means for all examined fractionated rates of Mn(2+) infusion. In this current study, we achieved a significantly higher dose of Mn(2+) (180 mg/kg) than that employed in previous studies without any observable toxic effects on animal physiology or behavior.
Collapse
Affiliation(s)
- Stephanie I Mok
- Section on Neural Gene Expression, National Institute of Mental Health, National Institutes of Health, DHHS, 9000 Rockville Pike, Building 49, Room 5A51, Bethesda, MD 20892-4483, USA
| | | | | |
Collapse
|
12
|
Bouvet M, Hoffman RM. In vivo imaging of pancreatic cancer with fluorescent proteins in mouse models. Methods Mol Biol 2012; 872:51-67. [PMID: 22700403 DOI: 10.1007/978-1-61779-797-2_4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
In this chapter, we describe protocols for clinically-relevant, metastatic orthotopic mouse models of pancreatic cancer, made imageable with genetic reporters. These models utilize human pancreatic-cancer cell lines which have been genetically engineered to selectively express high levels of green fluorescent protein (GFP) or red fluorescent protein (RFP). Tumors with fluorescent genetic reporters are established subcutaneously in nude mice by injection of the GFP- or RFP-expressing pancreatic cancer cell lines, and fragments of the subcutaneous tumors are then surgically transplanted onto the pancreas of additional nude mice. Loco-regional tumor growth and distant metastasis of these orthotopic tumors occurs spontaneously and rapidly throughout the abdomen in a manner consistent with clinical human disease. Highly-specific, high-resolution, real-time quantitative fluorescence imaging of tumor growth, and metastasis is achieved in vivo without the need for contrast agents, invasive techniques, or expensive imaging equipment. Transplantation of RFP-expressing tumor fragments onto the pancreas of GFP- or cyan fluorescent protein (CFP)-expressing transgenic nude mice was used to facilitate visualization of tumor-host interaction between the pancreatic cancer cells and host-derived stroma and vasculature. Such in vivo models have enabled us to visualize in real time and acquire images of the progression of pancreatic cancer in the live animal. These models can demonstrate the real-time antitumor and antimetastatic effects of novel therapeutic strategies on pancreatic malignancy. These fluorescent models are therefore powerful and reliable tools with which to investigate metastatic human pancreatic cancer and novel therapeutic strategies directed against it.
Collapse
Affiliation(s)
- Michael Bouvet
- GI Cancer Unit, Moores Cancer Center, University of California San Diego, La Jolla, CA, USA.
| | | |
Collapse
|
13
|
Abstract
Fusion imaging of radionuclide-based molecular (PET) and structural data [x-ray computed tomography (CT)] has been firmly established. Here we show that optical measurements [fluorescence-mediated tomography (FMT)] show exquisite congruence to radionuclide measurements and that information can be seamlessly integrated and visualized. Using biocompatible nanoparticles as a generic platform (containing a (18)F isotope and a far red fluorochrome), we show good correlations between FMT and PET in probe concentration (r(2) > 0.99) and spatial signal distribution (r(2) > 0.85). Using a mouse model of cancer and different imaging probes to measure tumoral proteases, macrophage content and integrin expression simultaneously, we demonstrate the distinct tumoral locations of probes in multiple channels in vivo. The findings also suggest that FMT can serve as a surrogate modality for the screening and development of radionuclide-based imaging agents.
Collapse
|
14
|
Liu J, Arends R, Martens A, den Brok-Bardoel MHC, Scheepers MGH, van Blitterswijk CA, de Boer J. Noninvasive imaging of bone-specific collagen I expression in a luciferase transgenic mouse model. Tissue Eng Part C Methods 2010; 16:1297-304. [PMID: 20218816 DOI: 10.1089/ten.tec.2009.0594] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Luciferase transgenic mice are a very promising tool for noninvasive, quantitative, and longitudinal evaluation of gene expression. The aim of this study was to validate the Col(I)-Luc transgenic mouse model in which the luciferase gene is driven by bone-specific regulatory elements from the mouse collagen α1(I) gene for bioluminescent imaging of bone development and remodeling. We observed strong luciferase activity in skeletal tissues of Col(I)-Luc mice, and observed that the light intensity declined with postnatal bone development. Luciferase activity was enhanced in a tail bone repair model and we were able to monitor the process of ectopic bone formation induced by recombinant human bone morphogenetic protein 2 using bioluminescent imaging. We conclude that Col(I)-Luc transgenic mice can be applied in the field of bone tissue engineering for monitoring bone repair processes and for investigating osteoinductive molecules or scaffolds.
Collapse
Affiliation(s)
- Jun Liu
- Department of Tissue Regeneration, MIRA Research Institute, University of Twente, Enschede, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
15
|
Nowakowski A, Alonso-Martín S, González-Manchón C, Larrucea S, Fernández D, Vilar M, Cerdán S, Ayuso MS, Parrilla R. Ventricular enlargement associated with the panneural ablation of the podocalyxin gene. Mol Cell Neurosci 2010; 43:90-7. [DOI: 10.1016/j.mcn.2009.09.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2009] [Revised: 09/14/2009] [Accepted: 09/25/2009] [Indexed: 10/20/2022] Open
|
16
|
Heerschap A, Kan HE, Nabuurs CIHC, Renema WK, Isbrandt D, Wieringa B. In vivo magnetic resonance spectroscopy of transgenic mice with altered expression of guanidinoacetate methyltransferase and creatine kinase isoenzymes. Subcell Biochem 2008; 46:119-48. [PMID: 18652075 DOI: 10.1007/978-1-4020-6486-9_7] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/20/2023]
Abstract
Mice with an under- or over-expression of enzymes catalyzing phosphoryl transfer in high-energy supplying reactions are particulary attractive for in vivo magnetic resonance spectroscopy (MRS) studies as substrates of these enzymes are visible in MR spectra. This chapter reviews results of in vivo MRS studies on transgenic mice with alterations in the expression of the enzymes creatine kinase and guanidinoacetate methyltransferase. The particular metabolic consequences of these enzyme deficiencies in skeletal muscle, brain, heart and liver are addressed. An overview is given of metabolite levels determined by in vivo MRS in skeletal muscle and brain of wild-type and transgenic mice. MRS studies on mice lacking guanidinoacetate methyltransferase have demonstrated metabolic changes comparable to those found in the deficiency of this enzyme in humans, which are (partly) reversible upon creatine feeding. Apart from being a model for a creatine deficiency syndrome, these mice are also of interest to study fundamental aspects of the biological role of creatine. MRS studies on transgenic mice lacking creatine kinase isoenzymes have contributed significantly to the view that the creatine kinase reaction together with other enzymatic steps involved in high-energy phosphate transfer builds a large metabolic energy network, which is highly versatile and can dynamically adapt to genotoxic or physiological challenges.
Collapse
Affiliation(s)
- Arend Heerschap
- Department of Radiology, Radboud University Nijmegen Medical Centre, 6500 HB Nijmegen, the Netherlands
| | | | | | | | | | | |
Collapse
|
17
|
Klaunberg BA, Davis JA. Considerations for laboratory animal imaging center design and setup. ILAR J 2008; 49:4-16. [PMID: 18172329 DOI: 10.1093/ilar.49.1.4] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
In vivo animal imaging is an outstanding noninvasive tool to study the pathophysiology of disease or response to therapy; additionally, serial imaging reduces the required number of experimental animals. Because of the tremendous capital investment, we recommend the imaging center be a shared resource to facilitate innovative and productive cross-disciplinary scientific collaborations. A shared center also enables a broader range of imaging, as equipment is often cost prohibitive for smaller facilities. A multitude of factors will determine the architectural design, facility efficiency, and functionality. Important considerations to determine during the planning stages include the types of animals to be imaged, types of imaging studies to be performed, types of imaging equipment and related services to be offered, and the location of the imaging center. Architects must work closely with manufacturers to accommodate equipment-related building specifications; facility planners and veterinarians can provide a practical logistical design that will ensure efficient functionality. Miscellaneous considerations include biosecurity levels, use of radioisotopes, and personnel safety in the imaging environment. The ideal imaging center will include space to house animals and perform necessary preimaging procedures, state-of-the-art in vivo imaging devices and the most up-to-date anesthesia, physiological support, and monitoring equipment. The center staff should include imaging specialists for technical development and data analysis. As it is difficult to provide a comprehensive manual for setting up an in vivo animal imaging center, we offer advice based on our experiences with the National Institutes of Health Mouse Imaging Facility. Because magnetic resonance imaging (MRI) is the most expensive imaging tool, requires specific building design considerations, and poses unique occupational health and safety risks, we focus on MRI as the foundation for an imaging facility design.
Collapse
Affiliation(s)
- Brenda A Klaunberg
- Mouse Imaging Facility, National Institute of Neurological Disorders and Stroke, National Institutes of Health, 10 Center Drive B1D-69, Bethesda, MD 20892, USA.
| | | |
Collapse
|
18
|
Liu T, Ding Y, Xie W, Li Z, Bai X, Li X, Fang W, Ren C, Wang S, Hoffman RM, Yao K. An imageable metastatic treatment model of nasopharyngeal carcinoma. Clin Cancer Res 2007; 13:3960-7. [PMID: 17606730 DOI: 10.1158/1078-0432.ccr-07-0089] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE Nasopharyngeal carcinoma is highly prevalent in southern China and is often resistant to current treatment options. EXPERIMENTAL DESIGN Clinically relevant mouse models are necessary for further understanding and drug discovery in this disease. Two nasopharyngeal carcinoma cell lines, stably expressing green fluorescent protein (GFP), 5-8F-GFP and 6-10B-GFP, were established. The cells were orthotopically injected into the nasopharynx or ectopically into the subcutis of nude mice. Whole-body fluorescence imaging was used to monitor the growth of the primary tumor as well as angiogenesis and metastasis. RESULTS The metastatic behavior of 5-8F and 6-10B were distinct in the orthotopic model. Orthotopic implantation of highly metastatic 5-8F cells resulted in brain invasion, cervical lymph node metastases, and pulmonary metastases similar to what is often observed in patients. Cell line 6-10B was less metastatic, which occasionally resulted in pulmonary metastasis. GFP enabled imaging of micrometastasis. Neither 5-8F nor 6-10B were metastatic in the s.c. site. These results indicated that, in addition to the cancer cell type, the host microenvironment was critical for metastasis to occur consistent with the "seed-and-soil" hypothesis. 5-8F was highly sensitive to 5-fluorouracil (5-FU), whereas 6-10B was moderately sensitive. CONCLUSIONS The imageable orthotopic model should play a critical role in elucidating the mechanisms involved in the growth, progression, metastasis, and angiogenesis of nasopharyngeal carcinoma and for evaluation of novel compounds with potential efficacy.
Collapse
Affiliation(s)
- Tengfei Liu
- Cancer Institute, Nanfang Hospital, Southern Medical University, Key Laboratory of Transcriptomics and Proteomics of Human Diseases, Xiang-Ya School of Medicine, Central South University, Guangzhou, China
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Renema WKJ, Kan HE, Wieringa B, Heerschap A. In vivo magnetic resonance spectroscopy of transgenic mouse models with altered high-energy phosphoryl transfer metabolism. NMR IN BIOMEDICINE 2007; 20:448-67. [PMID: 17274105 DOI: 10.1002/nbm.1117] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Studies of transgenic mice provide powerful means to investigate the in vivo biological significance of gene products. Mice with an under- or overexpression of enzymes involved in high-energy phosphoryl transfer (approximately P) are particulary attractive for in vivo MR spectroscopy studies as the substrates of these enzymes are metabolites that are visible in MR spectra. This review provides a brief overview of the strategies used for generation and study of genetically altered mice and introduces the reader to some practical aspects of in vivo MRS studies on mice. The major part of the paper reviews results of in vivo MRS studies on transgenic mice with alterations in the expression of enzymes involved in approximately P metabolism, such as creatine kinase, adenylate kinase and guanidinoacetate methyl transferase. The particular metabolic consequences of these enzyme deficiencies in skeletal muscle, brain, heart and liver are addressed. Additionally, the use of approximately P systems as markers of gene expression by MRS, such as after viral transduction of genes, is described. Finally, a compilation of tissue levels of metabolites in skeletal muscle, heart and brain of wild-type and transgenic mice, as determined by in vivo MRS, is given. During the last decade, transgenic MRS studies have contributed significantly to our understanding of the physiological role of phosphotransfer enzymes, and to the view that these enzymes together build a much larger metabolic energy network that is highly versatile and can dynamically adapt to intrinsic genotoxic and extrinsic physiological challenges.
Collapse
Affiliation(s)
- W Klaas Jan Renema
- Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands.
| | | | | | | |
Collapse
|
20
|
Martiniova L, Ohta S, Guion P, Schimel D, Lai EW, Klaunberg B, Jagoda E, Pacak K. Anatomical and Functional Imaging of Tumors in Animal Models: Focus on Pheochromocytoma. Ann N Y Acad Sci 2006; 1073:392-404. [PMID: 17102108 DOI: 10.1196/annals.1353.043] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
This review focuses on anatomical (computed tomography, magnetic resonance imaging) and functional (positron emission tomography) imaging methods for tumor localization and identification of experimentally induced tumors in animal models, especially pheochromocytoma. Although anatomical imaging can precisely locate primary and metastatic tumors, functional imaging has high specificity for some tumors, especially those of endocrine origin. This is due to the fact that endocrine tumor cells take up hormone precursors, express hormone receptors and transporters, and synthesize, store, and release hormones. These characteristic properties of endocrine tumors enable investigators to create highly specific radiopharmaceuticals, particularly for positron emission tomography. For example, localization of pheochromocytoma involves [18F]-6F-dopamine. It is a highly specific radiopharmaceutical since it uses the norepinephrine transporter system expressed in most pheochromocytoma cells. Here we review both anatomical and functional imaging methods that are used conjointly in order to localize and identify specific characteristics of tumors.
Collapse
Affiliation(s)
- Lucia Martiniova
- D.Sc., Building 10, Room 1E3140, National Institutes of Health, 10 Center Drive MSC-1583, Bethesda, MD 20892-1583.
| | | | | | | | | | | | | | | |
Collapse
|
21
|
Leung VYL, Chan D, Cheung KMC. Regeneration of intervertebral disc by mesenchymal stem cells: potentials, limitations, and future direction. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2006; 15 Suppl 3:S406-13. [PMID: 16845553 PMCID: PMC2335386 DOI: 10.1007/s00586-006-0183-z] [Citation(s) in RCA: 125] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2006] [Revised: 06/16/2006] [Accepted: 06/21/2006] [Indexed: 01/08/2023]
Abstract
Over the past few years, substantial progress has been made in the field of stem cell regeneration of the intervertebral disc. Autogenic mesenchymal stem cells in animal models can arrest intervertebral disc degeneration or even partially regenerate it and the effect is suggested to be dependent on the severity of degeneration. Mesenchymal stem cells (MSCs) are able to escape alloantigen recognition which is an advantage for allogenic transplantation. A number of injectable scaffolds have been described and various methods to pre-modulate MSCs' activity have been tested. In future, work will need to address the use of mesenchymal stem cells in large animal models and the fate of the implanted mesenchymal stem cells, particularly in the long term, in animals. This review examines the state-of-the-art in the field of stem cell regeneration of the intervertebral disc, and critically discusses, with scientific support, the issues involved, before stem cells could be used in human subjects.
Collapse
Affiliation(s)
- Victor Y. L. Leung
- Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong SAR, China
- Department of Biochemistry, The University of Hong Kong, Hong Kong SAR, China
| | - Danny Chan
- Department of Biochemistry, The University of Hong Kong, Hong Kong SAR, China
| | - Kenneth M. C. Cheung
- Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong SAR, China
- Department of Orthopedics and Traumatology, The University of Hong Kong Medical Centre, Queen Mary Hospital, Pokfulam Road, Hong Kong, China
| |
Collapse
|
22
|
Hudson M. The EU Physical Agents (EMF) Directive and its impact on MRI imaging in animal experiments: a submission by FRAME to the HSE. Altern Lab Anim 2006; 34:343-7. [PMID: 16831064 DOI: 10.1177/026119290603400302] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The EU Physical Agents (EMF) Directive, Directive 2004/40/EC, which threatens to greatly restrict the use of magnetic resonance imaging (MRI) in both clinical and research situations, will come into force on 30 April 2008. This could severely affect experimental animal welfare and scientific progress, as well as patient care. FRAME made a submission to a Health and Safety Executive round-table discussion about the Directive, held in January 2006, detailing concerns about the implications that the legislation would have on implementing the Three Rs in animal-based research and testing, and the subsequent consequences for animal welfare and the quality of scientific output. The submission is reproduced here, with additional comments on the outcome of the meeting and recommendations for further research into the consequences of the Directive.
Collapse
Affiliation(s)
- Michelle Hudson
- FRAME, 96-98 North Sherwood Street, Nottingham, NG1 4EE, UK.
| |
Collapse
|
23
|
Abstract
This article reviews recent developments in selected imaging technologies focused on the cardiovascular system. The techniques covered are: ultrasound biomicroscopy (UBM), microSPECT, microPET, near infrared imaging, and quantum dots. For each technique, the basic physical principles are explained and recent example applications demonstrated.
Collapse
Affiliation(s)
- Elliot R McVeigh
- Laboratory of Cardiac Energetics, NHLBI, National Institutes of Health, Bethesda, MD, USA.
| |
Collapse
|
24
|
Pogue BW, Davis SC, Song X, Brooksby BA, Dehghani H, Paulsen KD. Image analysis methods for diffuse optical tomography. JOURNAL OF BIOMEDICAL OPTICS 2006; 11:33001. [PMID: 16822050 DOI: 10.1117/1.2209908] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Three major analytical tools in imaging science are summarized and demonstrated relative to optical imaging in vivo. Standard resolution testing is optimal when infinite contrast is used and hardware evaluation is the goal. However, deep tissue imaging of absorption or fluorescent contrast agents in vivo often presents a different problem, which requires contrast-detail analysis. This analysis shows that the minimum detectable sizes are in the range of 1/10 the outer diameter, whereas minimum detectable contrast values are in the range of 10 to 20% relative to the continuous background values. This is estimated for objects being in the center of the domain being imaged, and as the heterogeneous region becomes closer to the surface, the lower limit on size and contrast can become arbitrarily low and more dictated by hardware specifications. Finally, if human observer detection of abnormalities in the images is the goal, as is standard in most radiological practice, receiver operating characteristic (ROC) curve and location receiver operating characteristic curve (LROC) are used. Each of these three major areas of image interpretation and analysis are reviewed in the context of medical imaging as well as how they are used to quantify the performance of diffuse optical imaging of tissue.
Collapse
Affiliation(s)
- Brian W Pogue
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire 03755, USA.
| | | | | | | | | | | |
Collapse
|
25
|
Sharp TL, Dence CS, Engelbach JA, Herrero P, Gropler RJ, Welch MJ. Techniques necessary for multiple tracer quantitative small-animal imaging studies. Nucl Med Biol 2006; 32:875-84. [PMID: 16253813 DOI: 10.1016/j.nucmedbio.2005.05.010] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2005] [Revised: 05/31/2005] [Accepted: 05/31/2005] [Indexed: 11/27/2022]
Abstract
INTRODUCTION An increasing number and variety of studies on rodent models are being conducted using small-animal positron emission tomography scanners. We aimed to determine if animal handling techniques could be developed to perform routine animal imaging in a timely and efficient manner and with minimal effect on animal physiology. These techniques need to be reproducible in the same animal while maintaining hemodynamic and physiological stability. METHODS The necessary techniques include (a) the use of inhalant anesthesia, (b) arterial and venous cannulation for multiple tracer administrations and blood sampling, (c) development of small-volume analytic columns and techniques and (d) measurement of the physiological environment during the imaging session. RESULTS We provide an example of a cardiac imaging study using four radiotracers (15O-water, 1-[11C]-acetate, 1-[11C]-palmitate and 1-[11C]-glucose) injected into normal rats. Plasma substrates, CO2 production and total metabolites were measured. The animals remained anesthetized over the entire imaging session, and their physiological state was maintained. CONCLUSION The intrastudy stability of the physiological measurements and substrate levels and interstudy reproducibility of the measurements are reported.
Collapse
Affiliation(s)
- Terry L Sharp
- Division of Radiological Sciences, The Mallinckrodt Institute of Radiology, Washington University School of Medicine, Campus Box 8225, St. Louis, MO 63110, USA
| | | | | | | | | | | |
Collapse
|
26
|
Ntziachristos V, Turner G, Dunham J, Windsor S, Soubret A, Ripoll J, Shih HA. Planar fluorescence imaging using normalized data. JOURNAL OF BIOMEDICAL OPTICS 2005; 10:064007. [PMID: 16409072 DOI: 10.1117/1.2136148] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Fluorescence imaging of tissues has gained significant attention in recent years due to the emergence of appropriate reporter technologies that enable noninvasive sensing of molecular function in vivo. Two major approaches have been used so far for fluorescence molecular imaging, i.e., epi-illumination (reflectance) imaging and fluorescence molecular tomography. Transillumination is an alternative approach that has been employed for imaging tissues in the past and could be similarly beneficial for fluorescence molecular imaging. We investigate data normalization schemes in reflectance and transillumination mode and experimentally demonstrate that normalized transillumination offers significant advantages over planar reflectance imaging and over nonnormalized methods. Our observations, based on phantoms and on postmortem and in vivo mouse measurements display image quality improvement, superior depth sensitivity, and improved imaging accuracy over the nonnormalized methods examined. Normalized planar imaging retains implementation simplicity and could be used to improve on standard fluorescence reflectance imaging and as a simplified alternative to the more integrated and accurate tomographic methods.
Collapse
Affiliation(s)
- Vasilis Ntziachristos
- Massachusetts General Hospital & Harvard Medical School, Center for Molecular Imaging Research, Laboratory for Biooptics and Molecular Imaging, Charlestown, Massachusetts 02129, USA.
| | | | | | | | | | | | | |
Collapse
|
27
|
Hermiston TW, Kirn DH. Genetically based therapeutics for cancer: similarities and contrasts with traditional drug discovery and development. Mol Ther 2005; 11:496-507. [PMID: 15771953 DOI: 10.1016/j.ymthe.2004.12.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2004] [Accepted: 12/07/2004] [Indexed: 11/22/2022] Open
Abstract
The field of molecular therapeutics is in its infancy and represents a promising and novel avenue for targeted cancer treatments. Like the small-molecule and antibody therapeutics before them, however, the genetic-based therapies will face significant research and development challenges in their maturation toward an approved cancer therapy. To facilitate this process, we outline and examine in this review the drug development process, briefly summarizing the research and development paradigms that have accompanied the recent successes of the small-molecule and antibody-based cancer therapeutics. Using this background, we compare and contrast the research and development experiences of small-molecule and antibody therapeutics with genetic-based cancer therapeutics, using oncolytic viruses as a defined example of an experimental molecular therapeutic for cancer.
Collapse
Affiliation(s)
- Terry W Hermiston
- Department of Gene Therapy, Berlex Biosciences, Richmond, CA 94941, USA.
| | | |
Collapse
|
28
|
Abstract
Magnetic resonance imaging (MRI) continues to have a large impact on the diagnosis and management of a number of diseases, especially diseases associated with brain injury. The strengths of MRI are the unique contrast that can be obtained, and the fact that it is not harmful and that it can be readily applied to human and animal models. The past decade has seen development of functional MRI techniques that measure aspects of hemodynamics and water diffusion that are playing an important role. Indeed, these techniques are having a major impact on management of brain injury. The development of MRI continues at a rapid pace and a renewed push to increased spatial and temporal resolution will extend the applicability of anatomical and functional MRI. Increased interest in molecular imaging using MRI is increasing the number of processes that can be imaged in the brain. This work reviews some new developments that are being made in anatomical, functional, and molecular MRI of the brain, with comments about usefulness for work in the area of neuroprotection.
Collapse
Affiliation(s)
- Alan P Koretsky
- Laboratory of Functional and Molecular Imaging, National Institutes of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland 20812, USA.
| |
Collapse
|
29
|
Ntziachristos V, Ripoll J, Wang LV, Weissleder R. Looking and listening to light: the evolution of whole-body photonic imaging. Nat Biotechnol 2005; 23:313-20. [PMID: 15765087 DOI: 10.1038/nbt1074] [Citation(s) in RCA: 950] [Impact Index Per Article: 50.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Optical imaging of live animals has grown into an important tool in biomedical research as advances in photonic technology and reporter strategies have led to widespread exploration of biological processes in vivo. Although much attention has been paid to microscopy, macroscopic imaging has allowed small-animal imaging with larger fields of view (from several millimeters to several centimeters depending on implementation). Photographic methods have been the mainstay for fluorescence and bioluminescence macroscopy in whole animals, but emphasis is shifting to photonic methods that use tomographic principles to noninvasively image optical contrast at depths of several millimeters to centimeters with high sensitivity and sub-millimeter to millimeter resolution. Recent theoretical and instrumentation advances allow the use of large data sets and multiple projections and offer practical systems for quantitative, three-dimensional whole-body images. For photonic imaging to fully realize its potential, however, further progress will be needed in refining optical inversion methods and data acquisition techniques.
Collapse
Affiliation(s)
- Vasilis Ntziachristos
- Center for Molecular Imaging Research, Massachusetts General Hospital & Harvard Medical School CNY149, 13th street 5406, Charlestown, Massachusetts 02129, USA.
| | | | | | | |
Collapse
|
30
|
Abstract
In this report, we present a new noninvasive 3-dimensional (3D) imaging technology for in vivo monitoring of the skeletal development of mice: flat-panel volumetric Computed Tomography (fpvCT). Long-term investigations of 4 mice are presented, with up to 14 scans of each mouse from postnatal day 0 to 86. Examinations of a newborn and an adult mouse, performed with fpvCT and clinical multislice CT (MSCT), demonstrate the superior image quality of high-resolution fpvCT.
Collapse
Affiliation(s)
- Martin Obert
- Universitätsklinikum Giessen, Abteilung Neuroradiologie, D-35385 Giessen, Germany.
| | | | | | | |
Collapse
|
31
|
Metzler SD, Jaszczak RJ, Patil NH, Vemulapalli S, Akabani G, Chin BB. Molecular imaging of small animals with a triple-head SPECT system using pinhole collimation. IEEE TRANSACTIONS ON MEDICAL IMAGING 2005; 24:853-62. [PMID: 16011314 DOI: 10.1109/tmi.2005.848357] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Pinhole collimation yields high sensitivity when the distance from the object to the aperture is small, as in the case of imaging small animals. Fine-resolution images may be obtained when the magnification is large since this mitigates the effect of detector resolution. Large magnifications in pinhole single-photon emission computed tomography (SPECT) may be obtained by using a collimator whose focal length is many times the radius of rotation. This may be achieved without truncation if the gamma camera is large. We describe a commercially available clinical scanner mated with pinhole collimation and an external linear stage. The pinhole collimation gives high magnification. The linear stage allows for helical pinhole SPECT. We have used the system to image radiolabeled molecules in phantoms and small animals.
Collapse
Affiliation(s)
- S D Metzler
- Department of Radiology, The University of Pennsylvania, Philadelphia, PA 19104, USA
| | | | | | | | | | | |
Collapse
|
32
|
Borg TK, Stewart JA, Sutton MA. Imaging the cardiovascular system: seeing is believing. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2005; 11:189-99. [PMID: 16060971 DOI: 10.1017/s1431927605050439] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2004] [Accepted: 12/20/2004] [Indexed: 05/03/2023]
Abstract
From the basic light microscope through high-end imaging systems such as multiphoton confocal microscopy and electron microscopes, microscopy has been and will continue to be an essential tool in developing an understanding of cardiovascular development, function, and disease. In this review we briefly touch on a number of studies that illustrate the importance of these forms of microscopy in studying cardiovascular biology. We also briefly review a number of imaging modalities such as computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, and positron emission tomography (PET) that, although they do not fall under the realm of microscopy, are imaging modalities that greatly complement microscopy. Finally we examine the role of proper imaging system calibration and the potential importance of calibration in understanding biological tissues, such as the cardiovascular system, that continually undergo deformation in response to strain.
Collapse
Affiliation(s)
- Thomas K Borg
- Department of Cell and Developmental Biology and Anatomy, University of South Carolina, Columbia, SC 29208, USA.
| | | | | |
Collapse
|
33
|
Toyama H, Ye D, Ichise M, Liow JS, Cai L, Jacobowitz D, Musachio JL, Hong J, Crescenzo M, Tipre D, Lu JQ, Zoghbi S, Vines DC, Seidel J, Katada K, Green MV, Pike VW, Cohen RM, Innis RB. PET imaging of brain with the β-amyloid probe, [11C]6-OH-BTA-1, in a transgenic mouse model of Alzheimer’s disease. Eur J Nucl Med Mol Imaging 2005; 32:593-600. [PMID: 15791432 DOI: 10.1007/s00259-005-1780-5] [Citation(s) in RCA: 90] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2005] [Accepted: 02/14/2005] [Indexed: 10/25/2022]
Abstract
PURPOSE The purpose of this study was to evaluate the capacity of [11C]6-OH-BTA-1 and positron emission tomography (PET) to quantify beta-amyloid (Abeta) plaques in the Tg2576 mouse model of Alzheimer's disease (AD). METHODS PET imaging was performed with the NIH ATLAS small animal scanner in six elderly transgenic mice (Tg2576; age 22.0+/-1.8 months; 23.6+/-2.6 g) overexpressing a mutated form of human beta-amyloid precursor protein (APP) known to result in the production of Abeta plaques, and in six elderly wild-type litter mates (age 21.8+/-1.6 months; 29.5+/-4.7 g). Dynamic PET scans were performed for 30 min in each mouse under 1% isoflurane inhalation anesthesia after a bolus injection of 13-46 MBq of [11C]6-OH-BTA-1. PET data were reconstructed with 3D OSEM. On the coronal PET image, irregular regions of interest (ROIs) were placed on frontal cortex (FR), parietal cortex (PA), striatum (ST), thalamus (TH), pons (PO), and cerebellum (CE), guided by a mouse stereotaxic atlas. Time-activity curves (TACs) (expressed as percent injected dose per gram normalized to body weight: % ID-kg/g) were obtained for FR, PA, ST, TH, PO, and CE. ROI-to-CE radioactivity ratios were also calculated. Following PET scans, sections of mouse brain prepared from anesthetized and fixative-perfused mice were stained with thioflavin-S. RESULTS TACs for [11C]6-OH-BTA-1 in all ROIs peaked early (at 30-55 s), with radioactivity washing out quickly thereafter in both transgenic and wild-type mice. Peak uptake in all regions was significantly lower in transgenic mice than in wild-type mice. During the later part of the washout phase (12-30 min), the mean FR/CE and PA/CE ratios were higher in transgenic than in wild-type mice (1.06+/-0.04 vs 0.98+/-0.07, p=0.04; 1.06+/-0.09 vs 0.93+/-0.08 p=0.02) while ST/CE, TH/CE, and PO/CE ratios were not. Ex vivo staining revealed widespread Abeta plaques in cortex, but not in cerebellum of transgenic mice or in any brain regions of wild-type mice. CONCLUSION Marked reductions in brain uptake of this radioligand in transgenic mice may be due to reduced cerebral blood flow relative to that in wild-type mice. Specific [11C]6-OH-BTA-1 binding to Abeta plaques, if any, is probably very low, as reflected in the small FR/CE and PA/CE ratio differences. FR/CE and PA/CE ratios are considerably higher in AD patients while Abeta plaque densities in 22-month-old transgenic mice may be expected to show essentially the same density as is observed in the AD brain. This implies that the absence of tracer retention in 22-month-old transgenic mice may be due to the smaller number of Abeta plaque binding sites and/or to lower affinity of the binding sites for [11C]6-OH-BTA-1 as compared with AD patients. [11C]6-OH-BTA-1 shows excellent brain uptake in mice.
Collapse
Affiliation(s)
- Hiroshi Toyama
- Department of Radiology, Fujita Health University, 1-98, Dengakugakubo, Kutsukake, Toyoake, 470-1192, Aichi, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Sills RC, Morgan DL, Herr DW, Little PB, George NM, Ton TV, Love NE, Maronpot RR, Johnson GA. Contribution of magnetic resonance microscopy in the 12-week neurotoxicity evaluation of carbonyl sulfide in Fischer 344 rats. Toxicol Pathol 2005; 32:501-10. [PMID: 15603534 DOI: 10.1080/01926230490493918] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
In this carbonyl sulfide (COS) study, magnetic resonance microscopy (MRM) and detailed light microscopic evaluation effectively functioned in parallel to assure that the distribution and degree of pathology in the brain was accurately represented. MRM is a powerful imaging modality that allows for excellent identification of neuroanatomical structures coupled with the ability to acquire 200 or more cross-sectional images of the brain, and the ability to display them in multiple planes. F344 rats were exposed to 200-600 ppm COS for up to 12 weeks. Prior to MRM, rats were anesthetized and cardiac perfused with McDowell Trump's fixative containing a gadolinium MR contrast medium. Fixed specimens were scanned at the Duke Center for In Vivo Microscopy on a 9.4 Tesla magnetic resonance system adapted explicitly for microscopic imaging. An advantage of MRM in this study was the ability to identify lesions in rats that appeared clinically normal prior to sacrifice and the opportunity to identify lesions in areas of the brain which would not be included in conventional studies. Other advantages include the ability to examine the brain in multiple planes (transverse, dorsal, sagittal) and obtain and save the MRM images in a digital format that allows for postexperimental data processing and manipulation. MRM images were correlated with neuroanatomical and neuropathological findings. All suspected MRM images were compared to corresponding H&E slides. An important aspect of this study was that MRM was critical in defining our strategy for sectioning the brain, and for designing mechanistic studies (cytochrome oxidase evaluations) and functional assessments (electrophysiology studies) on specifically targeted anatomical sites following COS exposure.
Collapse
Affiliation(s)
- Robert C Sills
- Laboratory of Experimental Pathology, NIEHS, Research Triangle Park, North Carolina 27709, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
35
|
Toyama H, Ichise M, Liow JS, Vines DC, Seneca NM, Modell KJ, Seidel J, Green MV, Innis RB. Evaluation of anesthesia effects on [18F]FDG uptake in mouse brain and heart using small animal PET. Nucl Med Biol 2004; 31:251-6. [PMID: 15013491 DOI: 10.1016/s0969-8051(03)00124-0] [Citation(s) in RCA: 111] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2003] [Revised: 06/19/2003] [Accepted: 07/05/2003] [Indexed: 11/20/2022]
Abstract
This study evaluates effects of anesthesia on (18)F-FDG (FDG) uptake in mouse brain and heart to establish the basic conditions of small animal PET imaging. Prior to FDG injection, 12 mice were anesthetized with isoflurane gas; 11 mice were anesthetized with an intraperitoneal injection of a ketamine/xylazine mixture; and 11 mice were awake. In isoflurane and ketamine/xylazine conditions, FDG brain uptake (%ID/g) was significantly lower than in controls. Conversely, in the isoflurane condition, %ID/g in heart was significantly higher than in controls, whereas heart uptake in ketamine/xylazine mice was significantly lower. Results suggest that anesthesia impedes FDG uptake in mouse brain and affects FDG uptake in heart; however, the effects in the brain and heart differ depending on the type of anesthesia used.
Collapse
Affiliation(s)
- Hiroshi Toyama
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD 20892, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Heverhagen JT, Hahn HK, Wegmann M, Herz U, Shaffer Whitaker CD, Matschl V, Alfke H. Volumetric analysis of mice lungs in a clinical magnetic resonance imaging scanner. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2004; 17:80-5. [PMID: 15480944 DOI: 10.1007/s10334-004-0053-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2003] [Revised: 07/07/2004] [Accepted: 07/28/2004] [Indexed: 10/26/2022]
Abstract
Small animal models are widely used to study various pathologies. Magnetic resonance imaging (MRI) allows investigation of these animals in a non-invasive way. Therefore, the aim of our study was to develop and evaluate a low-cost approach to measure lung volumes in small animal MRI using a clinical scanner and a specially designed RF coil. Five mice (three of an established emphysema model and two controls) were investigated in a 1.0-T clinical scanner using a specially built small animal saddle coil and three different three-dimensional sequences; overall imaging time was approximately 16 min. Lung volumes were calculated from these images using an interactive watershed transform algorithm for semi-automatic image segmentation. The gold standard for the volume measurement was water displacement after surgical explantation. MRI measured volumes correlated significantly with ex vivo measurements on the explanted lungs (r = 0.99 to 0.89; p < 0.05). Mean lung volume in emphysema model mice was larger than in controls. High-resolution, small animal MRI using a clinical scanner is feasible for volumetric analysis and provides an alternative to a dedicated small animal scanner.
Collapse
|
37
|
Bluestone AY, Stewart M, Lasker J, Abdoulaev GS, Hielscher AH. Three-dimensional optical tomographic brain imaging in small animals, part 1: hypercapnia. JOURNAL OF BIOMEDICAL OPTICS 2004; 9:1046-1062. [PMID: 15447026 DOI: 10.1117/1.1784471] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
In this study, we explore the potential of diffuse optical tomography for brain oximetry. While several groups have already reported on the sensitivity of optical measurements to changes in oxyhemoglobin, deoxyhemoglobin, and blood volume, these studies were often limited to single source-detector geometries or topographic maps, where signals obtained from within the brain are projected onto 2-D surface maps. In this two-part study, we report on our efforts toward developing a volumetric optical imaging system that allows one to spatially resolve 3-D hemodynamic effects in rat brains. In part 1, we describe the instrumentation, optical probe design, and the model-based iterative image reconstruction algorithm employed in this work. Consideration of how a priori anatomical knowledge can be incorporated in the reconstruction process is presented. This system is then used to monitor global hemodynamic changes that occur in the brain under various degrees of hypercapnia. The physiologic cerebral response to hypercapnia is well known and therefore allows an initial performance assessment of the imaging system. As expected, we observe global changes in blood volume and oxygenation, which vary linearly as a function of the concentration of the inspired carbon dioxide. Furthermore, experiments are designed to determine the sensitivity of the reconstructions of only 1 mm to inaccurate probe positioning. We determine that shifts can significantly influence the reconstructions. In part 2 we focus on more local hemodynamic changes that occur during unilateral carotid occlusion performed at lower-than-normal systemic blood pressure. In this case, the occlusion leads to a predominantly monohemispherically localized effect, which is well described in the literature. Having explored the system with a well-characterized physiologic effect, we investigate and discuss the complex compensatory cerebrovascular hemodynamics that occur at normotensive blood pressure. Overall, these studies demonstrate the potential and limitations of our diffuse optical imager for visualizing global and focal hemodynamic phenomenon three dimensionally in the brains of small animals.
Collapse
Affiliation(s)
- A Y Bluestone
- Columbia University, Departments of Biomedical Engineering and Radiology, New York, New York 10027, USA
| | | | | | | | | |
Collapse
|
38
|
Abstract
Calculations of radiation dose are important in assessing the medical and biological implications of ionizing radiation in medical imaging techniques such as SPECT and PET. In contrast, radiation dose estimates of SPECT and PET imaging of small animals are not very well established. For that reason we have estimated the whole-body radiation dose to mice and rats for isotopes such as 18F, 99mTc, 201Tl, (111)In, 123I, and 125I that are used commonly for small animal imaging. We have approximated mouse and rat bodies with uniform soft tissue equivalent ellipsoids. The mouse and rat sized ellipsoids had a mass of 30 g and 300 g, respectively, and a ratio of the principal axes of 1:1:4 and 0.7:1:4. The absorbed fractions for various photon energies have been calculated using the Monte Carlo software package MCNP. Using these values, we then calculated MIRD S-values for two geometries that model the distribution of activity in the animal body: (a) a central point source and (b) a homogeneously distributed source, and compared these values against S-value calculations for small ellipsoids tabulated in MIRD Pamphlet 8 to validate our results. Finally we calculated the radiation dose taking into account the biological half-life of the radiopharmaceuticals and the amount of activity administered. Our calculations produced S-values between 1.06 x 10(-13) Gy/Bq s and 2.77 x 10(-13) Gy/Bq s for SPECT agents, and 15.0 x 10(-13) Gy/Bq s for the PET agent 18F, assuming mouse sized ellipsoids with uniform source distribution. The S-values for a central point source in an ellipsoid are about 10% higher than the values obtained for the uniform source distribution. Furthermore, the S-values for mouse sized ellipsoids are approximately 10 times higher than for the rat sized ellipsoids reflecting the difference in mass. We reviewed published data to obtain administered radioactivity and residence times for small animal imaging. From these values and our computed S-values we estimated that the whole body dose in small animals ranges between 6 cGy and 90 cGy for mice and between about 1 cGy and 27 cGy for rats. The whole body dose in small animal imaging can be very high in comparison to the lethal dose to mice (LD50/30 approximately 7 Gy). For this reason the dose in small animal imaging should be monitored carefully and the administered activity should be kept to a minimum. These results also underscore the need of further development of instrumentation that improves detection efficiency and reduces radiation dose in small animal imaging.
Collapse
Affiliation(s)
- Tobias Funk
- UCSF Physics Research Laboratory, Department of Radiology, University of California, San Francisco, San Francisco, California 94107, USA
| | | | | |
Collapse
|
39
|
Klaunberg BA, Lizak MJ. Considerations for setting up a small-animal imaging facility. Lab Anim (NY) 2004; 33:28-34. [PMID: 15235626 PMCID: PMC7091868 DOI: 10.1038/laban0304-28] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2004] [Accepted: 01/30/2004] [Indexed: 11/08/2022]
Abstract
Imaging techniques allow for the conduct of noninvasive, in vivo longitudinal small-animal studies, but also require access to expensive and complex equipment, and personnel who are properly trained in their use. The authors describe their planning and staffing of the NIH Mouse Imaging Facility, and highlight important issues to consider when designing a similar facility.
Collapse
Affiliation(s)
- Brenda A. Klaunberg
- National Institutes of Health Mouse Imaging Facility, 10 Center Drive, Room B1D-69, Bethesda, MD
| | - Martin J. Lizak
- National Institutes of Health Mouse Imaging Facility, 10 Center Drive, Room B1D-69, Bethesda, MD
| |
Collapse
|
40
|
Shapiro EM, Skrtic S, Sharer K, Hill JM, Dunbar CE, Koretsky AP. MRI detection of single particles for cellular imaging. Proc Natl Acad Sci U S A 2004; 101:10901-6. [PMID: 15256592 PMCID: PMC503717 DOI: 10.1073/pnas.0403918101] [Citation(s) in RCA: 365] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
There is rapid growth in the use of MRI for molecular and cellular imaging. Much of this work relies on the high relaxivity of nanometer-sized, ultrasmall dextran-coated iron oxide particles. Typically, millions of dextran-coated ultrasmall iron oxide particles must be loaded into cells for efficient detection. Here we show that single, micrometer-sized iron oxide particles (MPIOs) can be detected by MRI in vitro in agarose samples, in cultured cells, and in mouse embryos. Experiments studying effects of MRI resolution and particle size from 0.76 to 1.63 microm indicated that T(2)* effects can be readily detected from single MPIOs at 50-microm resolution and significant signal effects could be detected at resolutions as low as 200 microm. Cultured cells were labeled with fluorescent MPIOs such that single particles were present in individual cells. These single particles in single cells could be detected both by MRI and fluorescence microscopy. Finally, single particles injected into single-cell-stage mouse embryos could be detected at embryonic day 11.5, demonstrating that even after many cell divisions, daughter cells still carry individual particles. These results demonstrate that MRI can detect single particles and indicate that single-particle detection will be useful for cellular imaging.
Collapse
Affiliation(s)
- Erik M Shapiro
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, 9000 Rockville Pike, Bethesda, MD 20892, USA.
| | | | | | | | | | | |
Collapse
|
41
|
Yang Y, Tai YC, Siegel S, Newport DF, Bai B, Li Q, Leahy RM, Cherry SR. Optimization and performance evaluation of the microPET II scanner forin vivosmall-animal imaging. Phys Med Biol 2004; 49:2527-45. [PMID: 15272672 DOI: 10.1088/0031-9155/49/12/005] [Citation(s) in RCA: 117] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
MicroPET II is a newly developed PET (positron emission tomography) scanner designed for high-resolution imaging of small animals. It consists of 17,640 LSO crystals each measuring 0.975 x 0.975 x 12.5 mm3, which are arranged in 42 contiguous rings, with 420 crystals per ring. The scanner has an axial field of view (FOV) of 4.9 cm and a transaxial FOV of 8.5 cm. The purpose of this study was to carefully evaluate the performance of the system and to optimize settings for in vivo mouse and rat imaging studies. The volumetric image resolution was found to depend strongly on the reconstruction algorithm employed and averaged 1.1 mm (1.4 microl) across the central 3 cm of the transaxial FOV when using a statistical reconstruction algorithm with accurate system modelling. The sensitivity, scatter fraction and noise-equivalent count (NEC) rate for mouse- and rat-sized phantoms were measured for different energy and timing windows. Mouse imaging was optimized with a wide open energy window (150-750 keV) and a 10 ns timing window, leading to a sensitivity of 3.3% at the centre of the FOV and a peak NEC rate of 235,000 cps for a total activity of 80 MBq (2.2 mCi) in the phantom. Rat imaging, due to the higher scatter fraction, and the activity that lies outside of the field of view, achieved a maximum NEC rate of 24,600 cps for a total activity of 80 MBq (2.2 mCi) in the phantom, with an energy window of 250-750 keV and a 6 ns timing window. The sensitivity at the centre of the FOV for these settings is 2.1%. This work demonstrates that different scanner settings are necessary to optimize the NEC count rate for different-sized animals and different injected doses. Finally, phantom and in vivo animal studies are presented to demonstrate the capabilities of microPET II for small-animal imaging studies.
Collapse
Affiliation(s)
- Yongfeng Yang
- Department of Biomedical Engineering, University of California-Davis, One Shields Avenue, Davis, CA 95616, USA
| | | | | | | | | | | | | | | |
Collapse
|
42
|
Ma B, Sherman PS, Moskwa JE, Koeppe RA, Kilbourn MR. Sensitivity of [11C]N-methylpyrrolidinyl benzilate ([11C]NMPYB) to endogenous acetylcholine: PET imaging vs tissue sampling methods. Nucl Med Biol 2004; 31:393-7. [PMID: 15093808 DOI: 10.1016/j.nucmedbio.2003.12.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2003] [Accepted: 12/20/2003] [Indexed: 11/17/2022]
Abstract
Administration of phenserine, an acetylcholinesterase inhibitor, raises endogenous brain acetylcholine levels and has been previously shown to reduce in vivo binding of the muscarinic cholinergic receptor antagonist [(11)C]N-methylpyrrolidinyl benzilate ([(11)C]NMPYB) in the awake rat brain. In this study, phenserine pretreatment was studied in both awake and isoflurane-anesthetized rats using the techniques of ex vivo dissection or in vivo microPET imaging. In ex vivo dissection experiments, a statistically significant 10% inhibition of [(11)C]NMPYB binding could be demonstrated in both awake and anesthetized animals after phenserine pretreatment, showing no deleterious effect of using isoflurane anesthesia. However, microPET imaging in anesthetized animals failed to successfully demonstrate inhibition of [(11)C]NMPYB binding following the identical phenserine treatment protocol. These results demonstrate that in small numbers of subjects ex vivo dissection may be a more sensitive experimental method for determining small changes of in vivo radiotracer binding in this model of neurotransmitter competition for brain receptor sites.
Collapse
Affiliation(s)
- Bing Ma
- Division of Nuclear Medicine, Department of Radiology, University of Michigan Medical School, 3480 Kresge III Building, Ann Arbor, MI 48109, USA
| | | | | | | | | |
Collapse
|
43
|
Abstract
Molecular imaging is a rapidly evolving discipline with the goal of developing tools to display and quantify molecular and cellular targets in vivo. The heart of this field is based on the rational design and screening of targeted and activatable imaging reporter agents to sense fundamental processes of biology. Parallel advances in small animal imaging systems and in agent synthesis have allowed molecular imaging applications to extend into the in vivo arena. These advances have permitted, for example, in vivo sensing of inflammation, apoptosis, cell trafficking, and gene expression. In this review, we first review core principles of molecular imaging with an emphasis on smart, activatable agent technology. We then discuss applications of state-of-the-art molecular probes to interrogate important aspects of cardiovascular biology, with a focus on atherosclerosis, thrombosis, and heart failure. In the ensuing years, we anticipate that fundamental aspects of cardiovascular biology will be detectable in vivo, and that promising molecular imaging agents will be translated into the clinical arena to guide diagnosis and therapy of human cardiovascular illness.
Collapse
Affiliation(s)
- Farouc A Jaffer
- Center for Molecular Imaging Research, Massachusetts General Hospital, Harvard Medical School, Charlestown, Mass 02129, USA.
| | | |
Collapse
|
44
|
Reijnders K, English SJ, Krishna MC, Cook JA, Sowers AL, Mitchell JB, Zhang Y. Influence of body temperature on the BOLD effect in murine SCC tumors. Magn Reson Med 2004; 51:389-93. [PMID: 14755665 DOI: 10.1002/mrm.10695] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Changes in the blood oxygen level dependent (BOLD) enhancements in tumors (squamous cell carcinoma, (SCCVII)) implanted in mice maintained at core temperatures of 30 degrees C or 37 degrees C were measured using MRI and compared to tumor oxygen levels obtained using an oxygen-sensitive Eppendorf electrode. Tumors were implanted in a hindleg of the mice intramuscularly. Tumor-bearing mice were imaged by BOLD MRI, while first breathing air and then carbogen (95% O2, 5% CO2) for 15-min intervals at a core temperature of 30 degrees C. After an equilibration period, the identical regimen was conducted with the same animal maintained at 37 degrees C. This procedure was repeated with additional mice starting at 37 degrees C followed by imaging at 30 degrees C. Likewise, oxygen electrode measurements of the tumor were determined at core temperatures of 30 degrees C and 37 degrees C. The Eppendorf measurements showed that tumors in animals maintained at 30 degrees C were significantly more hypoxic than at 37 degrees C. MRI studies demonstrated stronger BOLD enhancement at 30 degrees C than at 37 degrees C, suggesting significant changes in hypoxia and/or blood flow in tumors at these temperatures. The findings of the study stress the importance of maintaining normal core temperature when assessing tumor oxygen status using functional imaging modalities or oxygen-sensitive electrodes.
Collapse
Affiliation(s)
- Koen Reijnders
- Radiation Biology Branch, Center for Cancer Research, National Cancer Institute, Bethesda, Maryland 20892, USA
| | | | | | | | | | | | | |
Collapse
|
45
|
Rowland DJ, Lewis JS, Welch MJ. Molecular imaging: the application of small animal positron emission tomography. J Cell Biochem 2003; 39:110-5. [PMID: 12552610 DOI: 10.1002/jcb.10417] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The extraordinary advances in genomic technologies over the last decade have led to the establishment of new animal models of disease. The use of molecular imaging techniques to examine these models, preferably with non-destructive imaging procedures, such as those offered by positron emission tomography (PET), are especially valuable for the timely advancement of research. With the use of small animal PET imaging it is possible to follow individual subjects of a sample population over an extended time period by using highly specific molecular probes and radiopharmaceuticals. In this Prospect small animal PET imaging will be described, specifically focusing on the current technologies, its applications in molecular imaging and the logistics of performing small animal PET.
Collapse
Affiliation(s)
- Douglas J Rowland
- Radiation Sciences, Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis, Missouri, USA
| | | | | |
Collapse
|
46
|
Mahata SK, Mahapatra NR, Mahata M, Wang TC, Kennedy BP, Ziegler MG, O'Connor DT. Catecholamine secretory vesicle stimulus-transcription coupling in vivo. Demonstration by a novel transgenic promoter/photoprotein reporter and inhibition of secretion and transcription by the chromogranin A fragment catestatin. J Biol Chem 2003; 278:32058-67. [PMID: 12799369 DOI: 10.1074/jbc.m305545200] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Stimulation of chromaffin cell secretion in vitro triggers not only secretion but also resynthesis of just released catecholamines and chromogranin A, the precursor of the catecholamine release-inhibitory, nicotinic cholinergic antagonist peptide catestatin. Does stimulus-transcription coupling occur in vivo? And does catestatin antagonize secretion and transcription in vivo? To answer these questions, we employed a novel mouse strain harboring a chromogranin A promoter/firefly luciferase reporter transgene. Tissue-specific expression of the reporter was established by both luminescence and reverse transcription-PCR. Secretion and transcription in vivo were triggered by either direct nicotinic stimulation or vesicular transmitter depletion. Nicotinic blockade in vivo was attempted with either the classical antagonist chlorisondamine or the novel antagonist catestatin. Luciferase reporter expression was exquisitely sensitive over a large dynamic range, was specific for the transgenic animals, and paralleled typical neuroendocrine distribution of endogenous chromogranin A. Adrenal ontogeny revealed a rise of embryonic transgene expression until embryonal day 18, with an abrupt postnatal decline. Direct nicotinic stimulation of chromaffin cells caused catecholamine release and transgene transcription, each of which was nearly completely blocked by chlorisondamine. Similar adrenal results were obtained during vesicular catecholamine depletion. Both secretion and transcription were substantially blocked in the adrenal gland by catestatin. In brain and sympathetic nerve, stimulation of transcription was more modest, and reserpine responses were only incompletely blocked by chlorisondamine or catestatin, perhaps because of limited blood-brain barrier penetration by these cationic antagonists. Thus, nicotinic cholinergic stimulus-transcription coupling occurs in vivo and can be provoked either directly or indirectly (by vesicular transmitter depletion). Such coupling triggers the biosynthesis of chromogranin A, the precursor of catestatin. Catestatin itself blocks stimulation of both secretion and transcription in vivo. Thus, chromogranin A and its catestatin fragment may lie at the nexus of nicotinic cholinergic signaling in vivo.
Collapse
Affiliation(s)
- Sushil K Mahata
- Department of Medicine and Center for Molecular Genetics, University of California, and Veterans Affairs San Diego Healthcare System, San Diego, California 92161, USA
| | | | | | | | | | | | | |
Collapse
|
47
|
Lewis JS, Achilefu S, Garbow JR, Laforest R, Welch MJ. Small animal imaging. current technology and perspectives for oncological imaging. Eur J Cancer 2002; 38:2173-88. [PMID: 12387842 DOI: 10.1016/s0959-8049(02)00394-5] [Citation(s) in RCA: 116] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Advances in the biomedical sciences have been accelerated by the introduction of many new imaging technologies in recent years. With animal models widely used in the basic and pre-clinical sciences, finding ways to conduct animal experiments more accurately and efficiently becomes a key factor in the success and timeliness of research. Non-invasive imaging technologies prove to be extremely valuable tools in performing such studies and have created the recent surge in small animal imaging. This review is focused on three modalities, PET, MR and optical imaging which are available to the scientist for oncological investigations in animals.
Collapse
Affiliation(s)
- Jason S Lewis
- Radiation Sciences, Washington University School of Medicine, Saint Louis, MO, USA
| | | | | | | | | |
Collapse
|
48
|
Natt O, Watanabe T, Boretius S, Radulovic J, Frahm J, Michaelis T. High-resolution 3D MRI of mouse brain reveals small cerebral structures in vivo. J Neurosci Methods 2002; 120:203-9. [PMID: 12385770 DOI: 10.1016/s0165-0270(02)00211-x] [Citation(s) in RCA: 101] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
This work demonstrates technical approaches to high-quality magnetic resonance imaging (MRI) of small structures of the mouse brain in vivo. It turns out that excellent soft-tissue contrast requires the reduction of partial volume effects by using 3D MRI at high (isotropic) resolution with linear voxel dimensions of about 100-150 microm. The long T(2)* relaxation times at relatively low magnetic fields (2.35 T) offer the benefit of a small receiver bandwidth (increased signal-to-noise) at a moderate echo time which together with the small voxel size avoids visual susceptibility artifacts. For measuring times of 1-1.5 h both T(1)-weighted (FLASH) and T(2)-weighted (Fast Spin-Echo) 3D MRI acquisitions exhibit detailed anatomical insights in accordance with histological sections from a mouse brain atlas. Preliminary applications address the identification of neuroanatomical variations in different mouse strains and the use of Mn(2+) as a T(1) contrast agent for neuroaxonal tracing of fiber tracts within the mouse visual pathway.
Collapse
Affiliation(s)
- O Natt
- Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut für biophysikalische Chemie, 37070 Göttingen, Germany
| | | | | | | | | | | |
Collapse
|
49
|
Abstract
To advance our understanding of biological processes as they occur in living animals, imaging strategies have been developed and refined that reveal cellular and molecular features of biology and disease in real time. One rapid and accessible technology for in vivo analysis employs internal biological sources of light emitted from luminescent enzymes, luciferases, to label genes and cells. Combining this reporter system with the new generation of charge coupled device (CCD) cameras that detect the light transmitted through the animal's tissues has opened the door to sensitive in vivo measurements of mammalian gene expression in living animals. Here, we review the development and application of this imaging strategy, in vivo bioluminescence imaging (BLI), together with in vivo fluorescence imaging methods, which has enabled the real-time study of immune cell trafficking, of various genetic regulatory elements in transgenic mice, and of in vivo gene transfer. BLI has been combined with fluorescence methods that together offer access to in vivo measurements that were not previously available. Such studies will greatly facilitate the functional analysis of a wide range of genes for their roles in health and disease.
Collapse
Affiliation(s)
- Christopher H Contag
- Department of Pediatrics, Stanford University School of Medicine, California 94305-5208, USA.
| | | |
Collapse
|
50
|
Rovira Cañellas A. [New diagnostic applications of magnetic resonance in neurology]. Med Clin (Barc) 2002; 118:741-4. [PMID: 12049707 DOI: 10.1016/s0025-7753(02)72516-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|