Keenan KE, Tasdelen B, Javed A, Ramasawmy R, Rizzo R, Martin MN, Stupic KF, Seiberlich N, Campbell-Washburn AE, Nayak KS. T1 and T2 measurements across multiple 0.55T MRI systems using open-source vendor-neutral sequences. Magn Reson Med 2025; 93:289-300. [PMID: 39219179 PMCID: PMC11518643 DOI: 10.1002/mrm.30281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2024] [Revised: 07/18/2024] [Accepted: 08/14/2024] [Indexed: 09/04/2024]
Abstract
PURPOSE To compare T1 and T2 measurements across commercial and prototype 0.55T MRI systems in both phantom and healthy participants using the same vendor-neutral pulse sequences, reconstruction, and analysis methods. METHODS Standard spin echo measurements and abbreviated protocol measurements of T1, B1, and T2 were made on two prototype 0.55 T systems and two commercial 0.55T systems using an ISMRM/NIST system phantom. Additionally, five healthy participants were imaged at each system using the abbreviated protocol for T1, B1, and T2 measurement. The phantom measurements were compared to NMR-based reference measurements to determine accuracy, and both phantom and in vivo measurements were compared to assess reproducibility and differences between the prototype and commercial systems. RESULTS Vendor-neutral sequences were implemented across all four systems, and the code for pulse sequences and reconstruction is freely available. For participants, there was no difference in the mean T1 and T2 relaxation times between the prototype and commercial systems. In the phantom, there were no significant differences between the prototype and commercial systems for T1 and T2 measurements using the abbreviated protocol. CONCLUSION Quantitative T1 and T2 measurements at 0.55T in phantom and healthy participants are not statistically different across the prototype and commercial systems.
Collapse
Affiliation(s)
- Kathryn E Keenan
- National Institute of Standards and Technology, Boulder, Colorado, USA
| | - Bilal Tasdelen
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA
| | - Ahsan Javed
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Rudy Rizzo
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA
| | - Michele N Martin
- National Institute of Standards and Technology, Boulder, Colorado, USA
| | - Karl F Stupic
- National Institute of Standards and Technology, Boulder, Colorado, USA
| | - Nicole Seiberlich
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Krishna S Nayak
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
2
|
Kara D, Liu Y, Chen S, Garrett T, Younis A, Sugawara M, Bolen MA, Bi X, Wazni O, Nakagawa H, Kwon D, Nguyen C. In vivo cardiac diffusion tensor imaging on an MR system featuring ultrahigh performance gradients with 200 mT/m maximum gradient strength. Magn Reson Med 2024. [PMID: 39313764 DOI: 10.1002/mrm.30308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Revised: 08/01/2024] [Accepted: 09/03/2024] [Indexed: 09/25/2024]
Abstract
PURPOSE Our aim is to assess the potential of an MR system with ultrahigh performance gradients (200 mT/m maximum gradient strength) to address two interrelated challenges in cardiac DTI: low SNR and sensitivity to bulk motion. METHODS Imaging was performed in 20 healthy volunteers, two patients, and one swine post-myocardial infarction. The impact of maximum gradient strength was assessed with spin echo cardiac DTI featuring second-order motion compensation and varying maximum system gradient strengths (40, 80, 200 mT/m). Motion compensation requirements at 200 mT/m were assessed with sequences featuring zeroth-, first-, and second-order motion compensation. SNR, mean diffusivity, fractional anisotropy, helix angle transmurality, and secondary eigenvector angle in the left ventricle were compared. RESULTS Increasing maximum system gradient strength from 40 and 80 mT/m to 200 mT/m increased SNR of b = 500 s/mm2 images by 150% and 40% due to reductions in TE. Observed improvements in DTI metrics included reduction in variance in mean diffusivity and helix angle transmurality across healthy volunteers, improved visualization of myocardial borders and delineation of suspected scar. Whereas second-order motion compensation acquisitions were robust to motion-induced signal dropout, zeroth- and first-order motion compensation acquisitions suffered from severe signal loss and localized signal voids, respectively. CONCLUSION Ultrahigh performance gradients (200 mT/m) enable high SNR DWIs of the heart and resultant improvements in diffusion tensor metrics. Despite reduced diffusion-encoding duration, second-order motion compensation is required to overcome sensitivity to cardiac motion.
Collapse
Affiliation(s)
- Danielle Kara
- Cardiovascular Innovation Research Center, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Diagnostic Radiology, Imaging Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Yuchi Liu
- Cardiovascular MR R&D Collaborations, Siemens Medical Solutions USA, Inc., Malvern, Pennsylvania, USA
| | - Shi Chen
- Cardiovascular Innovation Research Center, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Thomas Garrett
- Cardiovascular Innovation Research Center, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Arwa Younis
- Department of Cardiovascular & Metabolic Science, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Cardiovascular Medicine, Heart Vascular Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Masafumi Sugawara
- Department of Cardiovascular & Metabolic Science, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Cardiovascular Medicine, Heart Vascular Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Michael A Bolen
- Diagnostic Radiology, Imaging Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Cardiovascular Medicine, Heart Vascular Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Xiaoming Bi
- Cardiovascular MR R&D Collaborations, Siemens Medical Solutions USA, Inc., Malvern, Pennsylvania, USA
| | - Oussama Wazni
- Cardiovascular Medicine, Heart Vascular Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Hiroshi Nakagawa
- Cardiovascular Medicine, Heart Vascular Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Deborah Kwon
- Cardiovascular Innovation Research Center, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Diagnostic Radiology, Imaging Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Cardiovascular Medicine, Heart Vascular Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Christopher Nguyen
- Cardiovascular Innovation Research Center, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Diagnostic Radiology, Imaging Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Cardiovascular Medicine, Heart Vascular Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Biomedical Engineering, Lerner Research Institute, Cleveland Clinic and Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
3
|
Afzali M, Mueller L, Coveney S, Fasano F, Evans CJ, Engel M, Szczepankiewicz F, Teh I, Dall'Armellina E, Jones DK, Schneider JE. In vivo diffusion MRI of the human heart using a 300 mT/m gradient system. Magn Reson Med 2024; 92:1022-1034. [PMID: 38650395 DOI: 10.1002/mrm.30118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 02/27/2024] [Accepted: 04/01/2024] [Indexed: 04/25/2024]
Abstract
PURPOSE This work reports for the first time on the implementation and application of cardiac diffusion-weighted MRI on a Connectom MR scanner with a maximum gradient strength of 300 mT/m. It evaluates the benefits of the increased gradient performance for the investigation of the myocardial microstructure. METHODS Cardiac diffusion-weighted imaging (DWI) experiments were performed on 10 healthy volunteers using a spin-echo sequence with up to second- and third-order motion compensation (M 2 $$ {M}_2 $$ andM 3 $$ {M}_3 $$ ) andb = 100 , 450 $$ b=100,450 $$ , and 1000s / m m 2 $$ \mathrm{s}/\mathrm{m}{\mathrm{m}}^2 $$ (twice theb max $$ {b}_{\mathrm{max}} $$ commonly used on clinical scanners). Mean diffusivity (MD), fractional anisotropy (FA), helix angle (HA), and secondary eigenvector angle (E2A) were calculated for b = [100, 450]s / m m 2 $$ \mathrm{s}/\mathrm{m}{\mathrm{m}}^2 $$ and b = [100, 1000]s / m m 2 $$ \mathrm{s}/\mathrm{m}{\mathrm{m}}^2 $$ for bothM 2 $$ {M}_2 $$ andM 3 $$ {M}_3 $$ . RESULTS The MD values withM 3 $$ {M}_3 $$ are slightly higher than withM 2 $$ {M}_2 $$ withΔ MD = 0 . 05 ± 0 . 05 [ × 1 0 - 3 mm 2 / s ] ( p = 4 e - 5 ) $$ \Delta \mathrm{MD}=0.05\pm 0.05\kern0.3em \left[\times 1{0}^{-3}\kern0.3em {\mathrm{mm}}^2/\mathrm{s}\right]\kern0.3em \left(p=4e-5\right) $$ forb max = 450 s / mm 2 $$ {b}_{\mathrm{max}}=450\kern0.3em \mathrm{s}/{\mathrm{mm}}^2 $$ andΔ MD = 0 . 03 ± 0 . 03 [ × 1 0 - 3 mm 2 / s ] ( p = 4 e - 4 ) $$ \Delta \mathrm{MD}=0.03\pm 0.03\kern0.3em \left[\times \kern0.3em 1{0}^{-3}\kern0.3em {\mathrm{mm}}^2/\mathrm{s}\right]\kern0.3em \left(p=4e-4\right) $$ forb max = 1000 s / mm 2 $$ {b}_{\mathrm{max}}=1000\kern0.3em \mathrm{s}/{\mathrm{mm}}^2 $$ . A reduction in MD is observed by increasing theb max $$ {b}_{\mathrm{max}} $$ from 450 to 1000s / mm 2 $$ \mathrm{s}/{\mathrm{mm}}^2 $$ (Δ MD = 0 . 06 ± 0 . 04 [ × 1 0 - 3 mm 2 / s ] ( p = 1 . 6 e - 9 ) $$ \Delta \mathrm{MD}=0.06\pm 0.04\kern0.3em \left[\times \kern0.3em 1{0}^{-3}\kern0.3em {\mathrm{mm}}^2/\mathrm{s}\right]\kern0.3em \left(p=1.6e-9\right) $$ forM 2 $$ {M}_2 $$ andΔ MD = 0 . 08 ± 0 . 05 [ × 1 0 - 3 mm 2 / s ] ( p = 1 e - 9 ) $$ \Delta \mathrm{MD}=0.08\pm 0.05\kern0.3em \left[\times \kern0.3em 1{0}^{-3}\kern0.3em {\mathrm{mm}}^2/\mathrm{s}\right]\kern0.3em \left(p=1e-9\right) $$ forM 3 $$ {M}_3 $$ ). The difference between FA, E2A, and HA was not significant in different schemes (p > 0 . 05 $$ p>0.05 $$ ). CONCLUSION This work demonstrates cardiac DWI in vivo with higher b-value and higher order of motion compensated diffusion gradient waveforms than is commonly used. Increasing the motion compensation order fromM 2 $$ {M}_2 $$ toM 3 $$ {M}_3 $$ and the maximum b-value from 450 to 1000 s / mm 2 $$ \mathrm{s}/{\mathrm{mm}}^2 $$ affected the MD values but FA and the angular metrics (HA and E2A) remained unchanged. Our work paves the way for cardiac DWI on the next-generation MR scanners with high-performance gradient systems.
Collapse
Affiliation(s)
- Maryam Afzali
- Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, UK
| | - Lars Mueller
- Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Sam Coveney
- Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Fabrizio Fasano
- Siemens Healthcare Ltd, Camberly, UK
- Siemens Healthcare GmbH, Erlangen, Germany
| | - Christopher John Evans
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, UK
| | - Maria Engel
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, UK
| | | | - Irvin Teh
- Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Erica Dall'Armellina
- Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Derek K Jones
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, UK
| | - Jürgen E Schneider
- Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| |
Collapse
|
4
|
Qi Y, Wang F, Kong J, Cao JJ, Li YY. SwinUNet: a multiscale feature learning approach to cardiovascular magnetic resonance parametric mapping for myocardial tissue characterization. Physiol Meas 2024; 45:035007. [PMID: 38387052 DOI: 10.1088/1361-6579/ad2c15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Accepted: 02/22/2024] [Indexed: 02/24/2024]
Abstract
Objective.Cardiovascular magnetic resonance (CMR) can measure T1 and T2 relaxation times for myocardial tissue characterization. However, the CMR procedure for T1/T2 parametric mapping is time-consuming, making it challenging to scan heart patients routinely in clinical practice. This study aims to accelerate CMR parametric mapping with deep learning.Approach. A deep-learning model, SwinUNet, was developed to accelerate T1/T2 mapping. SwinUNet used a convolutional UNet and a Swin transformer to form a hierarchical 3D computation structure, allowing for analyzing CMR images spatially and temporally with multiscale feature learning. A comparative study was conducted between SwinUNet and an existing deep-learning model, MyoMapNet, which only used temporal analysis for parametric mapping. The T1/T2 mapping performance was evaluated globally using mean absolute error (MAE) and structural similarity index measure (SSIM). The clinical T1/T2 indices for characterizing the left-ventricle myocardial walls were also calculated and evaluated using correlation and Bland-Altman analysis.Main results. We performed accelerated T1 mapping with ≤4 heartbeats and T2 mapping with 2 heartbeats in reference to the clinical standard, which required 11 heartbeats for T1 mapping and 3 heartbeats for T2 mapping. SwinUNet performed well in all the experiments (MAE < 50 ms, SSIM > 0.8, correlation > 0.75, and Bland-Altman agreement limits < 100 ms for T1 mapping; MAE < 1 ms, SSIM > 0.9, correlation > 0.95, and Bland-Altman agreement limits < 1.5 ms for T2 mapping). When the maximal acceleration was used (2 heartbeats), SwinUNet outperformed MyoMapNet and gave measurement accuracy similar to the clinical standard.Significance. SwinUNet offers an optimal solution to CMR parametric mapping for assessing myocardial diseases quantitatively in clinical cardiology.
Collapse
Affiliation(s)
- Yifan Qi
- Department of Computer Science, Stony Brook University, Stony Brook, NY 11790, United States of America
| | - Fusheng Wang
- Department of Computer Science, Stony Brook University, Stony Brook, NY 11790, United States of America
| | - Jun Kong
- Department of Mathematics and Statistics, Georgia State University, Atlanta, GA 30303, United States of America
| | - J Jane Cao
- DeMatteis Centre for Research and Education, St. Francis Hospital, Roslyn, NY 11576, United States of America
- Clinical medicine, Stony Brook University, Stony Brook, NY 11790, United States of America
| | - Yu Y Li
- DeMatteis Centre for Research and Education, St. Francis Hospital, Roslyn, NY 11576, United States of America
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11790, United States of America
| |
Collapse
|
5
|
Wang H, Deng W, Zhang Y, Yang J, Wang Z, Liu B, Han Y, Yu Y, Zhao R, Xiaohu Li. Changes in subclinical cardiac abnormalities 1 Year after recovering from COVID-19 in patients without clinical cardiac findings. Heliyon 2024; 10:e27380. [PMID: 38495174 PMCID: PMC10943378 DOI: 10.1016/j.heliyon.2024.e27380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 02/26/2024] [Accepted: 02/28/2024] [Indexed: 03/19/2024] Open
Abstract
Aim To evaluate the subclinical cardiac involvement in COVID-19 patients without clinical cardiac evidence using cardiac MR imaging. Material and methods Participants recovered from COVID-19 without cardiac symptoms and no cardiovascular medical history were enrolled in a prospective cohort study. They underwent baseline cardiac MR and follow-up cardiac MR > 300 days after discharge (n = 20). The study also included healthy controls (n = 20). Extracellular volume fraction (ECV), native T1, and 2D strain data were assessed and compared. Results The ECV values of participants at baseline [30.0% (28.3%-32.5%)] and at follow-up [31.0% (28.0%-32.8%)] were increased compared to the healthy control group [27.0% (25.3%-28.0%)] (both p < 0.001). However, the ECV increase from baseline cardiac MR to follow-up cardiac MR was not significant (p = 0.378). There was a statistically significant difference in global native T1 between baseline [1140 (1108.3-1192.0) ms] and follow-up [1176.0 (1113.0-1206.3) ms] (p = 0.016). However, no native T1 difference was found between the healthy controls [1160.7 (1119.6-1195.4) ms] and the baseline (p = 0.394) or follow-up group (p = 0.168). The global T2 was 41(40-42) ms at follow-up which was within the normal range. In addition, We found a recovery in 2D GLS among COVID-19 participants between baseline and follow-up [-12.4(-11.7 to -14.3)% vs. -17.2(-16.2 to -18.3)%; p<0.001]. Conclusion Using cardiac MR myocardial tissue and strain imaging parameters, 35% of people without cardiac symptoms or clinical evidence of myocardial injury still had subclinical myocardial tissue characteristic abnormalities at 300 days, but 2D GLS had recovered.
Collapse
Affiliation(s)
- Haitao Wang
- Department of Radiology, No.2 People's Hospital of Fuyang City, Fuyang, Anhui, China
| | - Wei Deng
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, Anhui Province, No. 218 Jixi Road, Hefei, 230022, China
| | - Yang Zhang
- Department of Radiology, Fuyang People's Hospital, Fuyang, 236015, Anhui Province, China
| | - Jinxiu Yang
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, Anhui Province, No. 218 Jixi Road, Hefei, 230022, China
| | - Zhen Wang
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, Anhui Province, No. 218 Jixi Road, Hefei, 230022, China
| | - Bin Liu
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, Anhui Province, No. 218 Jixi Road, Hefei, 230022, China
| | - Yuchi Han
- Cardiovascular Division, Wexner Medical Center, College of Medicine, The Ohio State University Medical Center, Columbus, OH, USA
| | - Yongqiang Yu
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, Anhui Province, No. 218 Jixi Road, Hefei, 230022, China
| | - Ren Zhao
- Department of Cardiology The First Affiliated Hospital of Anhui Medical University,Anhui, China
| | - Xiaohu Li
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, Anhui Province, No. 218 Jixi Road, Hefei, 230022, China
| |
Collapse
|
6
|
Thomas KE, Lukaschuk E, Shanmuganathan M, Kitt JA, Popescu IA, Neubauer S, Piechnik SK, Ferreira VM. Misclassification of females and males in cardiovascular magnetic resonance parametric mapping: the importance of sex-specific normal ranges for diagnosis of health vs. disease. Eur Heart J Cardiovasc Imaging 2024; 25:339-346. [PMID: 37788638 PMCID: PMC10883727 DOI: 10.1093/ehjci/jead247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 08/31/2023] [Accepted: 09/24/2023] [Indexed: 10/05/2023] Open
Abstract
AIMS Cardiovascular magnetic resonance parametric mapping enables non-invasive quantitative myocardial tissue characterization. Human myocardium has normal ranges of T1 and T2 values, deviation from which may indicate disease or change in physiology. Normal myocardial T1 and T2 values are affected by biological sex. Consequently, normal ranges created with insufficient numbers of each sex may result in sampling biases, misclassification of healthy values vs. disease, and even misdiagnoses. In this study, we investigated the impact of using male normal ranges for classifying female cases as normal or abnormal (and vice versa). METHODS AND RESULTS One hundred and forty-two healthy volunteers (male and female) were scanned on two Siemens 3T MR systems, providing averaged global myocardial T1 and T2 values on a per-subject basis. The Monte Carlo method was used to generate simulated normal ranges from these values to estimate the statistical accuracy of classifying healthy female or male cases correctly as 'normal' when using sex-specific vs. mixed-sex normal ranges. The normal male and female T1- and T2-mapping values were significantly different by sex, after adjusting for age and heart rate. CONCLUSION Using 15 healthy volunteers who are not sex specific to establish a normal range resulted in a typical misclassification of up to 36% of healthy females and 37% of healthy males as having abnormal T1 values and up to 16% of healthy females and 12% of healthy males as having abnormal T2 values. This paper highlights the potential adverse impact on diagnostic accuracy that can occur when local normal ranges contain insufficient numbers of both sexes. Sex-specific reference ranges should thus be routinely adopted in clinical practice.
Collapse
Affiliation(s)
- Katharine E Thomas
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Headley Way, Oxford OX3 9DU, UK
| | - Elena Lukaschuk
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Headley Way, Oxford OX3 9DU, UK
| | - Mayooran Shanmuganathan
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Headley Way, Oxford OX3 9DU, UK
| | - Jamie A Kitt
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Headley Way, Oxford OX3 9DU, UK
| | - Iulia A Popescu
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Headley Way, Oxford OX3 9DU, UK
| | - Stefan Neubauer
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Headley Way, Oxford OX3 9DU, UK
| | - Stefan K Piechnik
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Headley Way, Oxford OX3 9DU, UK
| | - Vanessa M Ferreira
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Level 0, John Radcliffe Hospital, Headley Way, Oxford OX3 9DU, UK
| |
Collapse
|
7
|
Huang Q, Mendes J, Adluru G, DiBella E. Technical note: Accuracy and precision of T2 and T2* with a gradient-echo spin-echo (GESE) sequence for cardiac imaging. Med Phys 2023; 50:7946-7954. [PMID: 37357805 DOI: 10.1002/mp.16569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 05/11/2023] [Accepted: 06/03/2023] [Indexed: 06/27/2023] Open
Abstract
BACKGROUND The use of a gradient echo spin echo (GESE) method to obtain rapid T2 and T2* estimation in the heart has been proposed. The effect of acquisition parameter settings on T2 and T2* bias and precision have not been investigated in depth. PURPOSE To understand factors impacting the quantification of T2 and T2* values with a gradient echo spin echo (GESE) method using echo planar imaging (EPI) readouts in a reduced field of view acquisition. METHODS The GESE method is implemented with a reduced field-of-view using an outer volume suppression (OVS) technique to minimize the time for multi-echo EPI readouts. The number of EPI readouts (images) for the GESE is optimized using Cramer-Rao Lower Bound (CRLB) and Monte Carlo simulations with a nonlinear least-square (NLLS) estimator. The SNR requirements were studied using the latter simulation method for a selected range of T2 and T2* values and T2/T2* ratios. Two healthy control subjects were imaged with the proposed GESE sequence and evaluated with the NLLS estimation method. In addition, the proposed OVS method was compared with a saturation bands OVS method in one subject. Clinical T2 and T2* mappings were used as the reference. RESULTS The optimal number of EPI readouts is five and the performance is slightly better when the refocusing pulse is placed between the 2nd and 3rd readouts. The SNR requirement for achieving a target bias < 1 ms and standard deviation (SD) < 5 ms is more demanding when T2/T2* ratio increases. The minimum SNR requirement in the GESE acquisition should vary from 6 to 20 depending on specific myocardial T2 and T2* values at 3T. The T2 and T2* estimates using the proposed OVS method and the saturation bands OVS method are both similar to the reference. CONCLUSION The GESE sequence with five EPI readouts is a feasible and efficient technique that can estimate T2 and T2* values in the septal myocardium within a heartbeat when the SNR requirement can be satisfied.
Collapse
Affiliation(s)
- Qi Huang
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, USA
| | - Jason Mendes
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA
| | - Ganesh Adluru
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, USA
| | - Edward DiBella
- Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
8
|
Xu Z, Li W, Wang J, Wang F, Sun B, Xiang S, Luo X, Meng Y, Wang X, Wang X, Song J, Zhang M, Xu D, Zhou X, Ju Z, Sun J, Han Y, Chen Y. Reference ranges of myocardial T1 and T2 mapping in healthy Chinese adults: a multicenter 3T cardiovascular magnetic resonance study. J Cardiovasc Magn Reson 2023; 25:64. [PMID: 37968645 PMCID: PMC10652608 DOI: 10.1186/s12968-023-00974-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 10/20/2023] [Indexed: 11/17/2023] Open
Abstract
BACKGROUND Although reference ranges of T1 and T2 mapping are well established for cardiovascular magnetic resonance (CMR) at 1.5T, data for 3T are still lacking. The objective of this study is to establish reference ranges of myocardial T1 and T2 based on a large multicenter cohort of healthy Chinese adults at 3T CMR. METHODS A total of 1015 healthy Chinese adults (515 men, age range: 19-87 years) from 11 medical centers who underwent CMR using 3T Siemens scanners were prospectively enrolled. T1 mapping was performed with a motion-corrected modified Look-Locker inversion recovery sequence using a 5(3)3 scheme. T2 mapping images were acquired using T2-prepared fast low-angle shot sequence. T1 and T2 relaxation times were quantified for each slice and each myocardial segment. The T1 mapping and extracellular volume standardization (T1MES) phantom was used for quality assurance at each center prior to subject scanning. RESULTS The phantom analysis showed strong consistency of spin echo, T1 mapping, and T2 mapping among centers. In the entire cohort, global T1 and T2 reference values were 1193 ± 34 ms and 36 ± 2.5 ms. Global T1 and T2 values were higher in females than in males (T1: 1211 ± 29 ms vs. 1176 ± 30 ms, p < 0.001; T2: 37 ± 2.3 ms vs. 35 ± 2.5 ms, p < 0.001). There were statistical differences in global T2 across age groups (p < 0.001), but not in global T1. Linear regression showed no correlation between age and global T1 or T2 values. In males, positive correlation was found between heart rate and global T1 (r = 0.479, p < 0.001). CONCLUSIONS Using phantom-validated imaging sequences, we provide reference ranges for myocardial T1 and T2 values on 3T scanners in healthy Chinese adults, which can be applied across participating sites. Trial registration URL: http://www.chictr.org.cn/index.aspx . Unique identifier: ChiCTR1900025518. Registration name: 3T magnetic resonance myocardial quantitative imaging standardization and reference value study: a multi-center clinical study.
Collapse
Affiliation(s)
- Ziqian Xu
- Department of Cardiology, West China Hospital, Sichuan University, Guoxue Xiang No. 37, Guo Xue Road, Chengdu, 610041, Sichuan, People's Republic of China
- Department of Radiology, West China Hospital, Sichuan University, Guoxue Xiang No. 37, Chengdu, 610041, Sichuan, People's Republic of China
| | - Weihao Li
- Department of Cardiology, West China Hospital, Sichuan University, Guoxue Xiang No. 37, Guo Xue Road, Chengdu, 610041, Sichuan, People's Republic of China
| | - Jiaqi Wang
- Department of Cardiology, West China Hospital, Sichuan University, Guoxue Xiang No. 37, Guo Xue Road, Chengdu, 610041, Sichuan, People's Republic of China
| | - Fei Wang
- Department of Radiology, Anqing Municipal Hospital, Renmin Road No. 352, Yingjiang District, Anqing, 246003, Anhui, People's Republic of China
| | - Bin Sun
- Department of Radiology, Fujian Medical University Union Hospital, Xinquan Road No. 29, Fuzhou, 350001, Fujian, People's Republic of China
| | - Shifeng Xiang
- Department of Radiology, Handan Central Hospital, Cong Taipei Road No. 59, Handan, 056002, Hebei, People's Republic of China
| | - Xiao Luo
- Department of Radiology, Maanshan People's Hospital, Hubei Road No. 45, Huashan District, Maanshan, 243099, Anhui, People's Republic of China
| | - Yanfeng Meng
- Department of Radiology, Taiyuan Central Hospital, East Sandao Lane No. 5, Jiefang North Road, Xinghualing District, Taiyuan, 030009, Shanxi, People's Republic of China
| | - Xiang Wang
- Department of Radiology, Wuhan Central Hospital, Shengli Street No. 26, Jiangan District, Wuhan, 430014, Hubei, People's Republic of China
| | - Ximing Wang
- Department of Radiology, Shandong Provincial Hospital, Jingwuwei Seventh Road No. 324, Huaiyin District, Jinan, 250021, Shandong, People's Republic of China
| | - Jianxun Song
- Department of Radiology, Shenzhen Baoan People's Hospital, Longjing 2nd Road No. 118, Xinan Street, Baoan District, Shenzhen, 518101, Guangdong, People's Republic of China
| | - Min Zhang
- Department of Radiology, Beijing Hospital, Dongdan Dahua Road No. 1, Dongcheng District, Beijing, 100005, People's Republic of China
| | - Dinghu Xu
- Department of Radiology, Nanjing Jiangning Hospital, Hushan Road No. 169, Jiangning District, Nanjing, 211199, Jiangsu, People's Republic of China
| | - Xiaoyue Zhou
- MR Collaboration, Siemens Healthineers Ltd, Shanghai, People's Republic of China
| | - Zhiguo Ju
- College of Medical Imaging, Shanghai University of Medicine & Health Science, Shanghai, People's Republic of China
| | - Jiayu Sun
- Department of Radiology, West China Hospital, Sichuan University, Guoxue Xiang No. 37, Chengdu, 610041, Sichuan, People's Republic of China
| | - Yuchi Han
- Cardiovascular Division, The Ohio State Wexner Medical Center, Columbus, OH, USA
| | - Yucheng Chen
- Department of Cardiology, West China Hospital, Sichuan University, Guoxue Xiang No. 37, Guo Xue Road, Chengdu, 610041, Sichuan, People's Republic of China.
| |
Collapse
|
9
|
Kim H, Yang YJ, Han K, Kim PK, Choi BW, Kim JY, Suh YJ. Validation of a deep learning-based software for automated analysis of T2 mapping in cardiac magnetic resonance imaging. Quant Imaging Med Surg 2023; 13:6750-6760. [PMID: 37869306 PMCID: PMC10585511 DOI: 10.21037/qims-23-375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Accepted: 08/01/2023] [Indexed: 10/24/2023]
Abstract
Background The reliability and diagnostic performance of deep learning (DL)-based automated T2 measurements on T2 map of 3.0-T cardiac magnetic resonance imaging (MRI) using multi-institutional datasets have not been investigated. We aimed to evaluate the performance of a DL-based software for measuring automated T2 values from 3.0-T cardiac MRI obtained at two centers. Methods Eighty-three subjects were retrospectively enrolled from two centers (42 healthy subjects and 41 patients with myocarditis) to validate a commercial DL-based software that was trained to segment the left ventricular myocardium and measure T2 values on T2 mapping sequences. Manual reference T2 values by two experienced radiologists and those calculated by the DL-based software were obtained. The segmentation performance of the DL-based software and the non-inferiority of automated T2 values were assessed compared with the manual reference standard per segment level. The software's performance in detecting elevated T2 values was assessed by calculating the sensitivity, specificity, and accuracy per segment. Results The average Dice similarity coefficient for segmentation of myocardium on T2 maps was 0.844. The automated T2 values were non-inferior to the manual reference T2 values on a per-segment analysis (45.35 vs. 44.32 ms). The DL-based software exhibited good performance (sensitivity: 83.6-92.8%; specificity: 82.5-92.0%; accuracy: 82.7-92.2%) in detecting elevated T2 values. Conclusions The DL-based software for automated T2 map analysis yields non-inferior measurements at the per-segment level and good performance for detecting myocardial segments with elevated T2 values compared with manual analysis.
Collapse
Affiliation(s)
- Hwan Kim
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Seoul, Korea
| | | | - Kyunghwa Han
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Seoul, Korea
| | | | - Byoung Wook Choi
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Seoul, Korea
- Phantomics Co., Ltd., Seoul, Korea
| | - Jin Young Kim
- Department of Radiology, Dongsan Hospital, Keimyung University College of Medicine, Daegu, Korea
| | - Young Joo Suh
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
10
|
Gröschel J, Trauzeddel RF, Müller M, von Knobelsdorff-Brenkenhoff F, Viezzer D, Hadler T, Blaszczyk E, Daud E, Schulz-Menger J. Multi-site comparison of parametric T1 and T2 mapping: healthy travelling volunteers in the Berlin research network for cardiovascular magnetic resonance (BER-CMR). J Cardiovasc Magn Reson 2023; 25:47. [PMID: 37574535 PMCID: PMC10424349 DOI: 10.1186/s12968-023-00954-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 07/10/2023] [Indexed: 08/15/2023] Open
Abstract
BACKGROUND Parametric mapping sequences in cardiovascular magnetic resonance (CMR) allow for non-invasive myocardial tissue characterization. However quantitative myocardial mapping is still limited by the need for local reference values. Confounders, such as field strength, vendors and sequences, make intersite comparisons challenging. This exploratory study aims to assess whether multi-site studies that control confounding factors provide first insights whether parametric mapping values are within pre-defined tolerance ranges across scanners and sites. METHODS A cohort of 20 healthy travelling volunteers was prospectively scanned at three sites with a 3 T scanner from the same vendor using the same scanning protocol and acquisition scheme. A Modified Look-Locker inversion recovery sequence (MOLLI) for T1 and a fast low-angle shot sequence (FLASH) for T2 were used. At one site a scan-rescan was performed to assess the intra-scanner reproducibility. All acquired T1- and T2-mappings were analyzed in a core laboratory using the same post-processing approach and software. RESULTS After exclusion of one volunteer due to an accidentally diagnosed cardiac disease, T1- and T2-maps of 19 volunteers showed no significant differences between the 3 T sites (mean ± SD [95% confidence interval] for global T1 in ms: site I: 1207 ± 32 [1192-1222]; site II: 1207 ± 40 [1184-1225]; site III: 1219 ± 26 [1207-1232]; p = 0.067; for global T2 in ms: site I: 40 ± 2 [39-41]; site II: 40 ± 1 [39-41]; site III 39 ± 2 [39-41]; p = 0.543). CONCLUSION Parametric mapping results displayed initial hints at a sufficient similarity between sites when confounders, such as field strength, vendor diversity, acquisition schemes and post-processing analysis are harmonized. This finding needs to be confirmed in a powered clinical trial. Trial registration ISRCTN14627679 (retrospectively registered).
Collapse
Affiliation(s)
- Jan Gröschel
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, ECRC Experimental and Clinical Research Center, Lindenberger Weg 80, 13125, Berlin, Germany
- Working Group On Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine, Lindenberger Weg 80, 13125, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| | - Ralf-Felix Trauzeddel
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, ECRC Experimental and Clinical Research Center, Lindenberger Weg 80, 13125, Berlin, Germany
- Working Group On Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine, Lindenberger Weg 80, 13125, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
- Department of Anaesthesiology and Intensive Care Medicine, Campus Benjamin Franklin, Charité, Universitätsmedizin Berlin, corporate member of Freie Universität Berlin Und Humboldt-Universität Zu Berlin, Berlin, Germany
| | - Maximilian Müller
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, ECRC Experimental and Clinical Research Center, Lindenberger Weg 80, 13125, Berlin, Germany
- Working Group On Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine, Lindenberger Weg 80, 13125, Berlin, Germany
| | - Florian von Knobelsdorff-Brenkenhoff
- Working Group On Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine, Lindenberger Weg 80, 13125, Berlin, Germany
- KIZ, Kardiologie im Zentrum, Eisenmannstr. 4, 80331, Munich, Deutschland
| | - Darian Viezzer
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, ECRC Experimental and Clinical Research Center, Lindenberger Weg 80, 13125, Berlin, Germany
- Working Group On Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine, Lindenberger Weg 80, 13125, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| | - Thomas Hadler
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, ECRC Experimental and Clinical Research Center, Lindenberger Weg 80, 13125, Berlin, Germany
- Working Group On Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine, Lindenberger Weg 80, 13125, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| | - Edyta Blaszczyk
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, ECRC Experimental and Clinical Research Center, Lindenberger Weg 80, 13125, Berlin, Germany
- Working Group On Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine, Lindenberger Weg 80, 13125, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| | - Elias Daud
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, ECRC Experimental and Clinical Research Center, Lindenberger Weg 80, 13125, Berlin, Germany
- Working Group On Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine, Lindenberger Weg 80, 13125, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
- The Cardiology Department, Galilee Medical Center, Azrieli Faculty of Medicine Bar-Ilan University, Nahariya, Safed, Israel
| | - Jeanette Schulz-Menger
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, ECRC Experimental and Clinical Research Center, Lindenberger Weg 80, 13125, Berlin, Germany.
- Working Group On Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine, Lindenberger Weg 80, 13125, Berlin, Germany.
- DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.
- Department of Cardiology and Nephrology, HELIOS Hospital Berlin-Buch, Berlin, Germany.
| |
Collapse
|
11
|
Topriceanu CC, Fornasiero M, Seo H, Webber M, Keenan KE, Stupic KF, Bruehl R, Ittermann B, Price K, McGrath L, Pang W, Hughes AD, Nezafat R, Kellman P, Pierce I, Moon JC, Captur G. Developing a medical device-grade T 2 phantom optimized for myocardial T 2 mapping by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2023; 25:19. [PMID: 36935515 PMCID: PMC10026458 DOI: 10.1186/s12968-023-00926-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Accepted: 01/26/2023] [Indexed: 03/21/2023] Open
Abstract
INTRODUCTION A long T2 relaxation time can reflect oedema, and myocardial inflammation when combined with increased plasma troponin levels. Cardiovascular magnetic resonance (CMR) T2 mapping therefore has potential to provide a key diagnostic and prognostic biomarkers. However, T2 varies by scanner, software, and sequence, highlighting the need for standardization and for a quality assurance system for T2 mapping in CMR. AIM To fabricate and assess a phantom dedicated to the quality assurance of T2 mapping in CMR. METHOD A T2 mapping phantom was manufactured to contain 9 T1 and T2 (T1|T2) tubes to mimic clinically relevant native and post-contrast T2 in myocardium across the health to inflammation spectrum (i.e., 43-74 ms) and across both field strengths (1.5 and 3 T). We evaluated the phantom's structural integrity, B0 and B1 uniformity using field maps, and temperature dependence. Baseline reference T1|T2 were measured using inversion recovery gradient echo and single-echo spin echo (SE) sequences respectively, both with long repetition times (10 s). Long-term reproducibility of T1|T2 was determined by repeated T1|T2 mapping of the phantom at baseline and at 12 months. RESULTS The phantom embodies 9 internal agarose-containing T1|T2 tubes doped with nickel di-chloride (NiCl2) as the paramagnetic relaxation modifier to cover the clinically relevant spectrum of myocardial T2. The tubes are surrounded by an agarose-gel matrix which is doped with NiCl2 and packed with high-density polyethylene (HDPE) beads. All tubes at both field strengths, showed measurement errors up to ≤ 7.2 ms [< 14.7%] for estimated T2 by balanced steady-state free precession T2 mapping compared to reference SE T2 with the exception of the post-contrast tube of ultra-low T1 where the deviance was up to 16 ms [40.0%]. At 12 months, the phantom remained free of air bubbles, susceptibility, and off-resonance artifacts. The inclusion of HDPE beads effectively flattened the B0 and B1 magnetic fields in the imaged slice. Independent temperature dependency experiments over the 13-38 °C range confirmed the greater stability of shorter vs longer T1|T2 tubes. Excellent long-term (12-month) reproducibility of measured T1|T2 was demonstrated across both field strengths (all coefficients of variation < 1.38%). CONCLUSION The T2 mapping phantom demonstrates excellent structural integrity, B0 and B1 uniformity, and reproducibility of its internal tube T1|T2 out to 1 year. This device may now be mass-produced to support the quality assurance of T2 mapping in CMR.
Collapse
Affiliation(s)
- Constantin-Cristian Topriceanu
- Barts Heart Center, Barts Health NHS Trust, West Smithfield, London, ECIA 7BE, UK
- Institute of Cardiovascular Science, University College London, Huntley Street, London, WC1E 6DD, UK
- Medical Research Council Unit for Lifelong Health and Ageing at UCL, 1-19 Torrington Place, London, WC1E 7HB, UK
| | | | - Han Seo
- Department of Cardiology, Center for Inherited Heart Muscle Conditions, Royal Free London NHS Foundation Trust, Pond Street, London, NW3 2QG, UK
| | - Matthew Webber
- Barts Heart Center, Barts Health NHS Trust, West Smithfield, London, ECIA 7BE, UK
- Institute of Cardiovascular Science, University College London, Huntley Street, London, WC1E 6DD, UK
- Department of Cardiology, Center for Inherited Heart Muscle Conditions, Royal Free London NHS Foundation Trust, Pond Street, London, NW3 2QG, UK
- Medical Research Council Unit for Lifelong Health and Ageing at UCL, 1-19 Torrington Place, London, WC1E 7HB, UK
| | - Kathryn E Keenan
- National Institute of Standards and Technology (NIST), 325 Broadway, Boulder, CO, 80305, USA
| | - Karl F Stupic
- National Institute of Standards and Technology (NIST), 325 Broadway, Boulder, CO, 80305, USA
| | - Rüdiger Bruehl
- Physikalisch-Technische Bundesanstalt (PTB), Abbestraße 2-12, 10587, Berlin, Germany
| | - Bernd Ittermann
- Physikalisch-Technische Bundesanstalt (PTB), Abbestraße 2-12, 10587, Berlin, Germany
| | - Kirsty Price
- UCL Bloomsbury Center for Clinical Phenotyping, London, WC1E 6HX, UK
| | - Louise McGrath
- UCL Bloomsbury Center for Clinical Phenotyping, London, WC1E 6HX, UK
| | - Wenjie Pang
- Resonance Health (RH), 141 Burswood Road, Burswood, WA, 6100, Australia
| | - Alun D Hughes
- Institute of Cardiovascular Science, University College London, Huntley Street, London, WC1E 6DD, UK
- Medical Research Council Unit for Lifelong Health and Ageing at UCL, 1-19 Torrington Place, London, WC1E 7HB, UK
| | - Reza Nezafat
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Ave, Boston, MA, 02215, USA
| | - Peter Kellman
- National Heart, Lung and Blood Institute, National Institutes of Health (NIH), Rockville Pike, Bethesda, MD, 20892, USA
| | - Iain Pierce
- Barts Heart Center, Barts Health NHS Trust, West Smithfield, London, ECIA 7BE, UK
- Institute of Cardiovascular Science, University College London, Huntley Street, London, WC1E 6DD, UK
| | - James C Moon
- Barts Heart Center, Barts Health NHS Trust, West Smithfield, London, ECIA 7BE, UK
- Institute of Cardiovascular Science, University College London, Huntley Street, London, WC1E 6DD, UK
| | - Gabriella Captur
- Institute of Cardiovascular Science, University College London, Huntley Street, London, WC1E 6DD, UK.
- Department of Cardiology, Center for Inherited Heart Muscle Conditions, Royal Free London NHS Foundation Trust, Pond Street, London, NW3 2QG, UK.
- Medical Research Council Unit for Lifelong Health and Ageing at UCL, 1-19 Torrington Place, London, WC1E 7HB, UK.
- Institute of Cardiovascular Science, Consultant Cardiologist in Inherited Heart Muscle Conditions, University College London, Gower Street, London, WC1E 6BT, UK.
| |
Collapse
|
12
|
Fingerprinting MINOCA: Unraveling Clues With Quantitative CMR. JACC Case Rep 2023; 7:101722. [PMID: 36776793 PMCID: PMC9911932 DOI: 10.1016/j.jaccas.2022.101722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 02/04/2023]
Abstract
In the following case series, we describe the clinical presentation of 2 patients with myocardial infarction with nonobstructive coronary arteries with different underlying pathophysiologic mechanisms. In both scenarios, cardiac magnetic resonance (CMR) imaging provided comprehensive tissue characterization with both conventional parametric mapping techniques and CMR fingerprinting. These cases demonstrate the diagnostic utility for CMR to elucidate the underlying etiology and appropriate therapeutic strategy. (Level of Difficulty: Advanced.).
Collapse
|
13
|
Bakogiannis C, Mouselimis D, Tsarouchas A, Papatheodorou E, Vassilikos VP, Androulakis E. Hypertrophic cardiomyopathy or athlete's heart? A systematic review of novel cardiovascular magnetic resonance imaging parameters. Eur J Sport Sci 2023; 23:143-154. [PMID: 34720041 DOI: 10.1080/17461391.2021.2001576] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Hypertrophic cardiomyopathy (HCM) is a common cause of sudden cardiac death in athletes. Cardiac Magnetic Resonance (CMR) imaging is considered an excellent tool to differentiate between HCM and athlete's heart. The aim of this systematic review was to highlight the novel CMR-derived parameters with significant discriminative capacity between the two conditions. A systematic search in the MEDLINE, EMBASE and Cochrane Reviews databases was performed. Eligible studies were considered the ones comparing novel CMR-derived parameters on athletes and HCM patients. Therefore, studies that only examined Cine-derived volumetric parameters were excluded. Particular attention was given to binary classification results from multi-variate regression models and ROC curve analyses. Bias assessment was performed with the Quality Assessment on Diagnostic Accuracy Studies. Five (5) studies were included in the systematic review, with a total of 284 athletes and 373 HCM patients. Several novel indices displayed discriminatory potential, such as native T1 mapping and T2 values, LV global longitudinal strain, late gadolinium enhancement and whole-LV fractal dimension. Diffusion tensor imaging enabled quantification of the secondary eigenvalue angle and fractional anisotropy in one study, which also proved capable of reliably detecting HCM in a mixed athlete/patient sample. Several novel CMR-derived parameters, most of which are currently under development, show promising results in discerning between athlete's heart and HCM. Prospective studies examining the discriminatory capacity of all promising modalities side-by-side will yield definitive answers on their relative importance; diagnostic models can incorporate the best performing variables for optimal results.
Collapse
Affiliation(s)
- Constantinos Bakogiannis
- Cardiovascular Prevention and Digital Cardiology Lab, Third Department of Cardiology, Hippokration Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Dimitrios Mouselimis
- Cardiovascular Prevention and Digital Cardiology Lab, Third Department of Cardiology, Hippokration Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Anastasios Tsarouchas
- Cardiovascular Prevention and Digital Cardiology Lab, Third Department of Cardiology, Hippokration Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | | | - Vassilios P Vassilikos
- Cardiovascular Prevention and Digital Cardiology Lab, Third Department of Cardiology, Hippokration Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | | |
Collapse
|
14
|
Franssen WMJ, Treibel TA, Seraphim A, Weingärtner S, Terenzi C. Model-free phasor image analysis of quantitative myocardial T 1 mapping. Sci Rep 2022; 12:19840. [PMID: 36400794 PMCID: PMC9674690 DOI: 10.1038/s41598-022-23872-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 11/07/2022] [Indexed: 11/19/2022] Open
Abstract
Model-free phasor image analysis, well established in fluorescence lifetime imaging and only recently applied to qMRI [Formula: see text] data processing, is here adapted and validated for myocardial qMRI [Formula: see text] mapping. Contrarily to routine mono-exponential fitting procedures, phasor enables mapping the lifetime information from all image voxels to a single plot, without resorting to any regression fitting analysis, and describing multi-exponential qMRI decays without biases due to violated modelling assumptions. In this feasibility study, we test the performance of our recently developed full-harmonics phasor method for unravelling partial-volume effects, motion or pathological tissue alteration, respectively on a numerically-simulated dataset, a healthy subject scan, and two pilot patient datasets. Our results show that phasor analysis can be used, as alternative method to fitting analysis or other model-free approaches, to identify motion artifacts or partial-volume effects at the myocardium-blood interface as characteristic deviations, or delineations of scar and remote myocardial tissue in patient data.
Collapse
Affiliation(s)
- Wouter M. J. Franssen
- grid.4818.50000 0001 0791 5666Laboratory of Biophysics, Wageningen University and Research, Wageningen, The Netherlands
| | - Thomas A. Treibel
- grid.83440.3b0000000121901201Institute of Cardiovascular Science, University College London, London, UK ,grid.416353.60000 0000 9244 0345Department of Cardiology, St Bartholomew’s Hospital, Barts Health NHS Trust, London, UK
| | - Andreas Seraphim
- grid.83440.3b0000000121901201Institute of Cardiovascular Science, University College London, London, UK ,grid.416353.60000 0000 9244 0345Department of Cardiology, St Bartholomew’s Hospital, Barts Health NHS Trust, London, UK
| | - Sebastian Weingärtner
- grid.5292.c0000 0001 2097 4740Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Camilla Terenzi
- grid.4818.50000 0001 0791 5666Laboratory of Biophysics, Wageningen University and Research, Wageningen, The Netherlands
| |
Collapse
|
15
|
Cavus E, Schneider JN, Bei der Kellen R, di Carluccio E, Ziegler A, Tahir E, Bohnen S, Avanesov M, Radunski UK, Chevalier C, Jahnke C, Ojeda F, Kirchhof P, Blankenberg S, Adam G, Lund GK, Muellerleile K. Impact of Sex and Cardiovascular Risk Factors on Myocardial T1, Extracellular Volume Fraction, and T2 at 3 Tesla: Results From the Population-Based, Hamburg City Health Study. Circ Cardiovasc Imaging 2022; 15:e014158. [PMID: 36126126 DOI: 10.1161/circimaging.122.014158] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
BACKGROUND Reliable reference intervals are crucial for clinical application of myocardial T1 and T2 mapping cardiovascular magnetic resonance imaging. This study evaluated the impact of sex and cardiovascular risk factors on myocardial T1, extracellular volume fraction (ECV), and T2 at 3T in the population-based HCHS (Hamburg City Health Study). METHODS The final study sample consisted of 1576 consecutive HCHS participants between 46 and 78 years without prevalent heart disease, including 1020 (67.3%) participants with hypertension and 110 (7.5%) with diabetes. T1 and T2 mapping were performed on a 3T scanner using 5b(3b)3b modified Look-Locker inversion recovery and T2 prepared, fast-low-angle shot sequence, respectively. Stepwise regression analyses were performed to identify variables with an independent impact on T1, ECV, and T2. Reference intervals were defined as the interval between the 2.5% and 97.5% quantiles. RESULTS Sex was the major independent influencing factor of myocardial native T1, ECV, and T2. Female patients had significantly higher upper limits of reference intervals for native T1 (1112-1261 versus 1079-1241 ms), ECV (23%-33% versus 22%-32%), and T2 (36-46 versus 35-45 ms) compared with male patients (all P<0.001). Cardiovascular risk factors, such as diabetes and hypertension, did not systematically affect native T1. There was an independent association of T2 by hypertension and, to a lesser degree, by left ventricular mass, heart rate (all P<0.001), and body mass index (P=0.001). CONCLUSIONS Sex needs to be considered as the major, independent influencing factor for clinical application of myocardial T1, ECV, and T2 measurements. Consequently, sex-specific reference intervals should be used in clinical routine. Our findings suggest that there is no need for specific reference intervals for myocardial T1 and ECV measurements in individuals with cardiovascular risk factors. However, hypertension should be considered as an additional factor for clinical application of T2 measurements. REGISTRATION URL: https://www. CLINICALTRIALS gov; Unique identifier: NCT03934957.
Collapse
Affiliation(s)
- Ersin Cavus
- Department of Cardiology, University Heart and Vascular Center Hamburg Eppendorf, Germany (E.C., J.N.S., R.B.d.K., E.d.C., A.Z., S. Bohnen, U.K.R., C.C., C.J., F.O., P.K., S. Blankenberg, K.M.).,Deutsches Zentrum für Herz-Kreislauf-Forschung e.V. (German Center for Cardiovascular Research), Partner Site Hamburg/Kiel/Lübeck, Germany (E.C., P.K., S. Blankenberg, K.M.)
| | - Jan N Schneider
- Department of Cardiology, University Heart and Vascular Center Hamburg Eppendorf, Germany (E.C., J.N.S., R.B.d.K., E.d.C., A.Z., S. Bohnen, U.K.R., C.C., C.J., F.O., P.K., S. Blankenberg, K.M.)
| | - Ramona Bei der Kellen
- Department of Cardiology, University Heart and Vascular Center Hamburg Eppendorf, Germany (E.C., J.N.S., R.B.d.K., E.d.C., A.Z., S. Bohnen, U.K.R., C.C., C.J., F.O., P.K., S. Blankenberg, K.M.)
| | - Eleonora di Carluccio
- Department of Cardiology, University Heart and Vascular Center Hamburg Eppendorf, Germany (E.C., J.N.S., R.B.d.K., E.d.C., A.Z., S. Bohnen, U.K.R., C.C., C.J., F.O., P.K., S. Blankenberg, K.M.).,Cardio-Care, Medizincampus Davos, Switzerland (E.d.C., A.Z.)
| | - Andreas Ziegler
- Department of Cardiology, University Heart and Vascular Center Hamburg Eppendorf, Germany (E.C., J.N.S., R.B.d.K., E.d.C., A.Z., S. Bohnen, U.K.R., C.C., C.J., F.O., P.K., S. Blankenberg, K.M.).,Cardio-Care, Medizincampus Davos, Switzerland (E.d.C., A.Z.).,School of Mathematics, Statistics and Computer Science, University of KwaZulu-Natal, Pietermaritzburg, South Africa (A.Z.)
| | - Enver Tahir
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Hospital Hamburg Eppendorf, Germany (E.T., M.A., G.A., G.K.L.)
| | - Sebastian Bohnen
- Department of Cardiology, University Heart and Vascular Center Hamburg Eppendorf, Germany (E.C., J.N.S., R.B.d.K., E.d.C., A.Z., S. Bohnen, U.K.R., C.C., C.J., F.O., P.K., S. Blankenberg, K.M.)
| | - Maxim Avanesov
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Hospital Hamburg Eppendorf, Germany (E.T., M.A., G.A., G.K.L.)
| | - Ulf K Radunski
- Department of Cardiology, University Heart and Vascular Center Hamburg Eppendorf, Germany (E.C., J.N.S., R.B.d.K., E.d.C., A.Z., S. Bohnen, U.K.R., C.C., C.J., F.O., P.K., S. Blankenberg, K.M.)
| | - Celeste Chevalier
- Department of Cardiology, University Heart and Vascular Center Hamburg Eppendorf, Germany (E.C., J.N.S., R.B.d.K., E.d.C., A.Z., S. Bohnen, U.K.R., C.C., C.J., F.O., P.K., S. Blankenberg, K.M.)
| | - Charlotte Jahnke
- Department of Cardiology, University Heart and Vascular Center Hamburg Eppendorf, Germany (E.C., J.N.S., R.B.d.K., E.d.C., A.Z., S. Bohnen, U.K.R., C.C., C.J., F.O., P.K., S. Blankenberg, K.M.)
| | - Francisco Ojeda
- Department of Cardiology, University Heart and Vascular Center Hamburg Eppendorf, Germany (E.C., J.N.S., R.B.d.K., E.d.C., A.Z., S. Bohnen, U.K.R., C.C., C.J., F.O., P.K., S. Blankenberg, K.M.)
| | - Paulus Kirchhof
- Department of Cardiology, University Heart and Vascular Center Hamburg Eppendorf, Germany (E.C., J.N.S., R.B.d.K., E.d.C., A.Z., S. Bohnen, U.K.R., C.C., C.J., F.O., P.K., S. Blankenberg, K.M.).,Deutsches Zentrum für Herz-Kreislauf-Forschung e.V. (German Center for Cardiovascular Research), Partner Site Hamburg/Kiel/Lübeck, Germany (E.C., P.K., S. Blankenberg, K.M.)
| | - Stefan Blankenberg
- Department of Cardiology, University Heart and Vascular Center Hamburg Eppendorf, Germany (E.C., J.N.S., R.B.d.K., E.d.C., A.Z., S. Bohnen, U.K.R., C.C., C.J., F.O., P.K., S. Blankenberg, K.M.).,Deutsches Zentrum für Herz-Kreislauf-Forschung e.V. (German Center for Cardiovascular Research), Partner Site Hamburg/Kiel/Lübeck, Germany (E.C., P.K., S. Blankenberg, K.M.)
| | - Gerhard Adam
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Hospital Hamburg Eppendorf, Germany (E.T., M.A., G.A., G.K.L.)
| | - Gunnar K Lund
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Hospital Hamburg Eppendorf, Germany (E.T., M.A., G.A., G.K.L.)
| | - Kai Muellerleile
- Department of Cardiology, University Heart and Vascular Center Hamburg Eppendorf, Germany (E.C., J.N.S., R.B.d.K., E.d.C., A.Z., S. Bohnen, U.K.R., C.C., C.J., F.O., P.K., S. Blankenberg, K.M.).,Deutsches Zentrum für Herz-Kreislauf-Forschung e.V. (German Center for Cardiovascular Research), Partner Site Hamburg/Kiel/Lübeck, Germany (E.C., P.K., S. Blankenberg, K.M.)
| |
Collapse
|
16
|
Topriceanu CC, Pierce I, Moon JC, Captur G. T 2 and T 2⁎ mapping and weighted imaging in cardiac MRI. Magn Reson Imaging 2022; 93:15-32. [PMID: 35914654 DOI: 10.1016/j.mri.2022.07.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 07/20/2022] [Accepted: 07/20/2022] [Indexed: 11/29/2022]
Abstract
Cardiac imaging is progressing from simple imaging of heart structure and function to techniques visualizing and measuring underlying tissue biological changes that can potentially define disease and therapeutic options. These techniques exploit underlying tissue magnetic relaxation times: T1, T2 and T2*. Initial weighting methods showed myocardial heterogeneity, detecting regional disease. Current methods are now fully quantitative generating intuitive color maps that do not only expose regionality, but also diffuse changes - meaning that between-scan comparisons can be made to define disease (compared to normal) and to monitor interval change (compared to old scans). T1 is now familiar and used clinically in multiple scenarios, yet some technical challenges remain. T2 is elevated with increased tissue water - oedema. Should there also be blood troponin elevation, this oedema likely reflects inflammation, a key biological process. T2* falls in the presence of magnetic/paramagnetic materials - practically, this means it measures tissue iron, either after myocardial hemorrhage or in myocardial iron overload. This review discusses how T2 and T2⁎ imaging work (underlying physics, innovations, dependencies, performance), current and emerging use cases, quality assurance processes for global delivery and future research directions.
Collapse
Affiliation(s)
- Constantin-Cristian Topriceanu
- Cardiac MRI Unit, Barts Heart Centre, West Smithfield, London, UK; UCL Institute of Cardiovascular Science, University College London, London, UK; UCL MRC Unit for Lifelong Health and Ageing, University College London, London, UK
| | - Iain Pierce
- Cardiac MRI Unit, Barts Heart Centre, West Smithfield, London, UK; UCL Institute of Cardiovascular Science, University College London, London, UK
| | - James C Moon
- Cardiac MRI Unit, Barts Heart Centre, West Smithfield, London, UK; UCL Institute of Cardiovascular Science, University College London, London, UK
| | - Gabriella Captur
- Cardiac MRI Unit, Barts Heart Centre, West Smithfield, London, UK; UCL Institute of Cardiovascular Science, University College London, London, UK; UCL MRC Unit for Lifelong Health and Ageing, University College London, London, UK; The Royal Free Hospital, Centre for Inherited Heart Muscle Conditions, Cardiology Department, Pond Street, Hampstead, London, UK.
| |
Collapse
|
17
|
O'Brien AT, Gil KE, Varghese J, Simonetti OP, Zareba KM. T2 mapping in myocardial disease: a comprehensive review. J Cardiovasc Magn Reson 2022; 24:33. [PMID: 35659266 PMCID: PMC9167641 DOI: 10.1186/s12968-022-00866-0] [Citation(s) in RCA: 61] [Impact Index Per Article: 30.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 04/27/2022] [Indexed: 12/20/2022] Open
Abstract
Cardiovascular magnetic resonance (CMR) is considered the gold standard imaging modality for myocardial tissue characterization. Elevated transverse relaxation time (T2) is specific for increased myocardial water content, increased free water, and is used as an index of myocardial edema. The strengths of quantitative T2 mapping lie in the accurate characterization of myocardial edema, and the early detection of reversible myocardial disease without the use of contrast agents or ionizing radiation. Quantitative T2 mapping overcomes the limitations of T2-weighted imaging for reliable assessment of diffuse myocardial edema and can be used to diagnose, stage, and monitor myocardial injury. Strong evidence supports the clinical use of T2 mapping in acute myocardial infarction, myocarditis, heart transplant rejection, and dilated cardiomyopathy. Accumulating data support the utility of T2 mapping for the assessment of other cardiomyopathies, rheumatologic conditions with cardiac involvement, and monitoring for cancer therapy-related cardiac injury. Importantly, elevated T2 relaxation time may be the first sign of myocardial injury in many diseases and oftentimes precedes symptoms, changes in ejection fraction, and irreversible myocardial remodeling. This comprehensive review discusses the technical considerations and clinical roles of myocardial T2 mapping with an emphasis on expanding the impact of this unique, noninvasive tissue parameter.
Collapse
Affiliation(s)
- Aaron T O'Brien
- Ohio University Heritage College of Osteopathic Medicine, Athens, Ohio, USA
| | - Katarzyna E Gil
- Department of Internal Medicine, Division of Cardiovascular Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Juliet Varghese
- Dorothy M. Davis Heart and Lung Research Institute, The Ohio State University, Columbus, Ohio, USA
| | - Orlando P Simonetti
- Department of Internal Medicine, Division of Cardiovascular Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
- Dorothy M. Davis Heart and Lung Research Institute, The Ohio State University, Columbus, Ohio, USA
- Department of Radiology, The Ohio State University, Columbus, Ohio, USA
| | - Karolina M Zareba
- Department of Internal Medicine, Division of Cardiovascular Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
- Dorothy M. Davis Heart and Lung Research Institute, The Ohio State University, Columbus, Ohio, USA.
| |
Collapse
|
18
|
Keenan KE, Delfino JG, Jordanova KV, Poorman ME, Chirra P, Chaudhari AS, Baessler B, Winfield J, Viswanath SE, deSouza NM. Challenges in ensuring the generalizability of image quantitation methods for MRI. Med Phys 2022; 49:2820-2835. [PMID: 34455593 PMCID: PMC8882689 DOI: 10.1002/mp.15195] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Revised: 08/17/2021] [Accepted: 08/17/2021] [Indexed: 01/31/2023] Open
Abstract
Image quantitation methods including quantitative MRI, multiparametric MRI, and radiomics offer great promise for clinical use. However, many of these methods have limited clinical adoption, in part due to issues of generalizability, that is, the ability to translate methods and models across institutions. Researchers can assess generalizability through measurement of repeatability and reproducibility, thus quantifying different aspects of measurement variance. In this article, we review the challenges to ensuring repeatability and reproducibility of image quantitation methods as well as present strategies to minimize their variance to enable wider clinical implementation. We present possible solutions for achieving clinically acceptable performance of image quantitation methods and briefly discuss the impact of minimizing variance and achieving generalizability towards clinical implementation and adoption.
Collapse
Affiliation(s)
- Kathryn E. Keenan
- Physical Measurement Laboratory, National Institute of Standards and Technology, 325 Broadway, Boulder, CO 80305, USA
| | - Jana G. Delfino
- Center for Devices and Radiological Health, US Food and Drug Administration, 10993 New Hampshire Ave, Silver Spring, MD 20993, USA
| | - Kalina V. Jordanova
- Physical Measurement Laboratory, National Institute of Standards and Technology, 325 Broadway, Boulder, CO 80305, USA
| | - Megan E. Poorman
- Physical Measurement Laboratory, National Institute of Standards and Technology, 325 Broadway, Boulder, CO 80305, USA
| | - Prathyush Chirra
- Dept of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH 44106, USA
| | - Akshay S. Chaudhari
- Department of Radiology, Stanford University, 450 Serra Mall, Stanford, CA 94305, USA
- Department of Biomedical Data Science, Stanford University, 450 Serra Mall, Stanford, CA 94305, USA
| | - Bettina Baessler
- University Hospital of Zurich and University of Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
| | - Jessica Winfield
- Cancer Research UK Cancer Imaging Centre, Division of Radiotherapy and Imaging, The Institute of Cancer Research, 123 Old Brompton Road, London, SW7 3RP, UK
- MRI Unit, Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey, SM2 5PT, UK
| | - Satish E. Viswanath
- Dept of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH 44106, USA
| | - Nandita M. deSouza
- Cancer Research UK Cancer Imaging Centre, Division of Radiotherapy and Imaging, The Institute of Cancer Research, 123 Old Brompton Road, London, SW7 3RP, UK
- MRI Unit, Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey, SM2 5PT, UK
| |
Collapse
|
19
|
Meloni A, Nicola M, Positano V, D'Angelo G, Barison A, Todiere G, Grigoratos C, Keilberg P, Pistoia L, Gargani L, Ripoli A, Pepe A. Myocardial T2 values at 1.5 T by a segmental approach with healthy aging and gender. Eur Radiol 2022; 32:2962-2975. [PMID: 35028749 DOI: 10.1007/s00330-021-08396-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 09/15/2021] [Accepted: 10/09/2021] [Indexed: 12/14/2022]
Abstract
OBJECTIVES Our aims were to obtain myocardial regional and global T2 values as a reference for normality for the first time using a GE scanner and to assess their association with physiological variables. METHODS One hundred healthy volunteers aged 20-70 years (50% females) underwent cardiovascular magnetic resonance. Basal, mid-ventricular, and apical short-axis slices of the left ventricle were acquired by a multi-echo fast-spin-echo (MEFSE) sequence. Image analysis was performed with a commercially available software package. The T2 value was assessed in all 16 myocardial segments and the global value was the mean. RESULTS The global T2 value averaged across all subjects was 52.2 ± 2.5 ms (range: 47.0-59.9 ms). Inter-study, intra-observer, and inter-observer reproducibility was good (coefficient of variation < 5%). 3.6% of the segments was excluded because of artifacts and/or partial-volume effects. Segmental T2 values differed significantly (p < 0.0001), with the lowest value in the basal anterolateral segment (50.0 ± 3.5 ms) and the highest in the apical lateral segment (54.9 ± 5.1 ms). Mean T2 was significantly lower in the basal slice compared to both mid-ventricular and apical slices and in the mid-ventricular slice than in the apical slice. Aging was associated with increased segmental and global T2 values. Females showed higher T2 values than males. T2 values were not correlated to heart rate. A significant inverse correlation was detected between global T2 values and mean wall thickness. CONCLUSIONS The optimized MEFSE sequence allows for robust and reproducible quantification of segmental T2 values. Gender- and age-specific segmental reference values must be defined for distinguishing healthy and diseased myocardium. KEY POINTS • In healthy subjects, T2 values differ among myocardial segments and are influenced by age and gender. • Normal T2 values in the myocardium, usable as a benchmark by other GE sites, were established.
Collapse
Affiliation(s)
- Antonella Meloni
- Magnetic Resonance Imaging Unit, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy.,Bioengineering Unit, Fondazione G. Monasterio CNR-Regione Toscana, Area della Ricerca S. Cataldo, Via Moruzzi, 1 -, 56124, Pisa, Italy
| | - Martini Nicola
- Magnetic Resonance Imaging Unit, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy.,Bioengineering Unit, Fondazione G. Monasterio CNR-Regione Toscana, Area della Ricerca S. Cataldo, Via Moruzzi, 1 -, 56124, Pisa, Italy
| | - Vincenzo Positano
- Magnetic Resonance Imaging Unit, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy.,Bioengineering Unit, Fondazione G. Monasterio CNR-Regione Toscana, Area della Ricerca S. Cataldo, Via Moruzzi, 1 -, 56124, Pisa, Italy
| | - Gennaro D'Angelo
- Institute of Clinical Physiology, National Research Council, Pisa, Italy
| | - Andrea Barison
- Division of Cardiology and Cardiovascular Medicine, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy
| | - Giancarlo Todiere
- Division of Cardiology and Cardiovascular Medicine, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy
| | - Chrysanthos Grigoratos
- Division of Cardiology and Cardiovascular Medicine, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy
| | - Petra Keilberg
- Magnetic Resonance Imaging Unit, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy
| | - Laura Pistoia
- Magnetic Resonance Imaging Unit, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy
| | - Luna Gargani
- Institute of Clinical Physiology, National Research Council, Pisa, Italy
| | - Andrea Ripoli
- Bioengineering Unit, Fondazione G. Monasterio CNR-Regione Toscana, Area della Ricerca S. Cataldo, Via Moruzzi, 1 -, 56124, Pisa, Italy
| | - Alessia Pepe
- Magnetic Resonance Imaging Unit, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy. .,Institute of Radiology, University of Padua, Padua, Italy.
| |
Collapse
|
20
|
Predictive value of major adverse cardiac events by T2-mapping texture analysis of the myocardial remote zone in patients with acute myocardial infarction. Clin Radiol 2022; 77:e241-e249. [DOI: 10.1016/j.crad.2021.12.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2021] [Accepted: 12/16/2021] [Indexed: 01/16/2023]
|
21
|
Hanson CA, Patel TR, Villines TC. The New Role of Cardiac Imaging Following the ISCHEMIA Trial. CURRENT TREATMENT OPTIONS IN CARDIOVASCULAR MEDICINE 2021; 23. [PMID: 34447240 DOI: 10.1007/s11936-021-00911-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Purpose of Review This review is aimed at summarizing the recently published ISCHEMIA trial (International Study of Comparative Health Effectiveness with Medical and Invasive Approaches) and how its findings may impact cardiac imaging for stable ischemic heart disease (SIHD) moving forward. Recent Findings The ISCHEMIA trial compared an initial invasive management strategy with goal of complete coronary revascularization versus an initial medical therapy strategy among stable patients with newly diagnosed moderate to severe myocardial ischemia on non-invasive testing. The trial results showed that an early invasive strategy did not reduce the incidence of major cardiovascular events over 3.2 years of follow-up as compared to optimal medical therapy in patients with SIHD. Summary The results of the landmark ISCHEMIA trial solidified the importance of guideline-directed medical therapy and have provided more evidence against the prevailing dogma that moderate to severe ischemia on traditional stress testing mandates coronary revascularization. This trial was not designed to compare different cardiac imaging and stress testing modalities for the assessment of coronary artery disease in patients undergoing their index evaluation for SIHD; however, its design, which included coronary computed tomographic angiography (CCTA) in most patients, and results have generated robust discussion regarding ways to improve non-invasive testing strategies in similar patient populations. We believe that increased utilization of CCTA to identify patients with and without high-risk SIHD, and advanced tests for ischemia, such as positron emission tomography and stress cardiac magnetic resonance imaging, when selected based on individual patient characteristics, may allow for improved decision-making and outcomes.
Collapse
Affiliation(s)
- Christopher A Hanson
- Division of Cardiovascular Medicine, University of Virginia Health System, Charlottesville, Virginia
| | - Toral R Patel
- Division of Cardiovascular Medicine, University of Virginia Health System, Charlottesville, Virginia
| | - Todd C Villines
- Division of Cardiovascular Medicine, University of Virginia Health System, Charlottesville, Virginia
| |
Collapse
|
22
|
Sieren MM, Maintz D, Gutberlet M, Krombach GA, Bamberg F, Hunold P, Lehmkuhl L, Fischbach K, Reinartz S, Antoch G, Barkhausen J, Sandstede J, Völker M, Naehle C. Current Status of Cardiovascular Imaging in Germany: Structured Data from the National Certification Program, ESCR Registry, and Survey among Radiologists. ROFO-FORTSCHR RONTG 2021; 194:181-191. [PMID: 34384112 DOI: 10.1055/a-1554-9236] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
PURPOSE In the light of the increasing importance of cardiovascular cross-sectional imaging in current guidelines, the goal of this study is to provide a comprehensive overview of cardiovascular imaging (CVI) offered by radiological institutions across Germany. MATERIALS AND METHODS Data were extracted from the national certification program database of the German Roentgen Society (DRG) from 2015-2021. A nationwide online survey among radiology institutes (university hospitals, non-university hospitals, and private practices) was conducted for 2019, and data was extracted from the European Society of Cardiovascular Radiology (ESCR) registry. The data collection's key points included the number of centers and individuals certified for CVI, the number of cardiac CT and MRI examinations performed, the reporting habits, and the participation in the ESCR registry. RESULTS 71 centers and 1278 persons, both with a substantial increase since 2015, were registered and certified by the DRG to perform CVI. According to the survey, a total of 69,286 CT and 64,281 MRI examinations were performed annually. Data from the survey and the ESCR registry indicated that reporting was mostly done solely by radiologists or, to a lesser degree, in joint consensus meetings with non-radiologists. The overall participation rate in the ESCR registry was 48 % among the survey's participants. CONCLUSION This comprehensive analysis demonstrates that high-quality CVI by radiologists is available nationwide. The current challenges are to provide the best medical and technical quality of CVI by radiology for patient care and to ensure economic sustainability in the German health care system to accommodate the predicted substantial need for CVI in the future. KEY POINTS · High-quality advanced CVI service by radiologists is available nationwide.. · Highly qualified specialist knowledge is widely represented from university to private practices.. · Certification programs successfully contribute to the dissemination & deepening of CVI expertise.. · The ESCR registry is an established international tool for the documentation of CVI.. CITATION FORMAT · Sieren M, Maintz D, Gutberlet M et al. Current Status of Cardiovascular Imaging in Germany: Structured Data from the National Certification Program, ESCR Registry, and Survey among Radiologists. Fortschr Röntgenstr 2021; DOI: 10.1055/a-1554-9236.
Collapse
Affiliation(s)
- Malte Maria Sieren
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein Campus Lübeck, Lübeck, Germany
| | - David Maintz
- Department for Interventional and Diagnostic Radiology, University Hospital Cologne, Germany
| | - Matthias Gutberlet
- Department for Diagnostic and Interventional Radiology, Heart Center Leipzig - University Leipzig, Germany.,Steering Committee Chair MRCT-Registry of the ESCR, ESCR, Vienna, Austria
| | - Gabriele Anja Krombach
- Department of Diagnostic and Interventional Radiology, University-Hospital Gießen, Germany
| | - Fabian Bamberg
- Department for Diagnostic and Interventional Radiology, University Hospital Freiburg, Germany
| | - Peter Hunold
- n/a, FOKUS Radiologie & Nuklearmedizin, Göttingen, Germany
| | - Lukas Lehmkuhl
- Department for Diagnostic and Interventional Radiology, RHÖN Clinic, Campus Bad Neustadt, Germany
| | - Katharina Fischbach
- Diagnostische Radiologie, Otto-von-Guericke-Universität, Magdeburg, Germany.,Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, Otto von Guericke University, Magdeburg, Germany
| | - Sebastian Reinartz
- Department for Diagnostic and Interventional Radiology, University Hospital Aachen, Germany
| | - Gerald Antoch
- Department for Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, University Hospital Düsseldorf, Germany
| | - Jörg Barkhausen
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein Campus Lübeck, Lübeck, Germany
| | - Jörn Sandstede
- Hamburg Wördemanns Weg, Radiologische Allianz, Hamburg, Germany.,Berufsverband der deutschen Radiologen e.V. (BDR), Munich, Germany
| | - Martin Völker
- Bereich Wissenschaft, Nachwuchsförderung, Zertifizierung, German Roentgen Society "Deutsche Röntgengesellschaft", Berlin, Germany
| | - Claas Naehle
- Department for Interventional and Diagnostic Radiology, University Hospital Cologne, Germany
| |
Collapse
|
23
|
Keenan KE, Gimbutas Z, Dienstfrey A, Stupic KF, Boss MA, Russek SE, Chenevert TL, Prasad PV, Guo J, Reddick WE, Cecil KM, Shukla-Dave A, Aramburu Nunez D, Shridhar Konar A, Liu MZ, Jambawalikar SR, Schwartz LH, Zheng J, Hu P, Jackson EF. Multi-site, multi-platform comparison of MRI T1 measurement using the system phantom. PLoS One 2021; 16:e0252966. [PMID: 34191819 PMCID: PMC8244851 DOI: 10.1371/journal.pone.0252966] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 05/26/2021] [Indexed: 11/19/2022] Open
Abstract
Recent innovations in quantitative magnetic resonance imaging (MRI) measurement methods have led to improvements in accuracy, repeatability, and acquisition speed, and have prompted renewed interest to reevaluate the medical value of quantitative T1. The purpose of this study was to determine the bias and reproducibility of T1 measurements in a variety of MRI systems with an eye toward assessing the feasibility of applying diagnostic threshold T1 measurement across multiple clinical sites. We used the International Society of Magnetic Resonance in Medicine/National Institute of Standards and Technology (ISMRM/NIST) system phantom to assess variations of T1 measurements, using a slow, reference standard inversion recovery sequence and a rapid, commonly-available variable flip angle sequence, across MRI systems at 1.5 tesla (T) (two vendors, with number of MRI systems n = 9) and 3 T (three vendors, n = 18). We compared the T1 measurements from inversion recovery and variable flip angle scans to ISMRM/NIST phantom reference values using Analysis of Variance (ANOVA) to test for statistical differences between T1 measurements grouped according to MRI scanner manufacturers and/or static field strengths. The inversion recovery method had minor over- and under-estimations compared to the NMR-measured T1 values at both 1.5 T and 3 T. Variable flip angle measurements had substantially greater deviations from the NMR-measured T1 values than the inversion recovery measurements. At 3 T, the measured variable flip angle T1 for one vendor is significantly different than the other two vendors for most of the samples throughout the clinically relevant range of T1. There was no consistent pattern of discrepancy between vendors. We suggest establishing rigorous quality control procedures for validating quantitative MRI methods to promote confidence and stability in associated measurement techniques and to enable translation of diagnostic threshold from the research center to the entire clinical community.
Collapse
Affiliation(s)
- Kathryn E. Keenan
- National Institute of Standards and Technology, Boulder, Colorado, United State of America
- * E-mail:
| | - Zydrunas Gimbutas
- National Institute of Standards and Technology, Boulder, Colorado, United State of America
| | - Andrew Dienstfrey
- National Institute of Standards and Technology, Boulder, Colorado, United State of America
| | - Karl F. Stupic
- National Institute of Standards and Technology, Boulder, Colorado, United State of America
| | - Michael A. Boss
- American College of Radiology, Center for Research and Innovation, Philadelphia, Pennsylvania, United State of America
| | - Stephen E. Russek
- National Institute of Standards and Technology, Boulder, Colorado, United State of America
| | | | - P. V. Prasad
- NorthShore University Health System, Evanston, Illinois, United State of America
| | - Junyu Guo
- St. Jude Children’s Research Hospital, Memphis, Tennessee, United State of America
| | - Wilburn E. Reddick
- St. Jude Children’s Research Hospital, Memphis, Tennessee, United State of America
| | - Kim M. Cecil
- Cincinnati Children’s Hospital Medical Center, University of Cincinnati College of Medicine Cincinnati, Ohio, United State of America
| | - Amita Shukla-Dave
- Memorial Sloan Kettering Cancer Center, New York, New York, United State of America
| | - David Aramburu Nunez
- Memorial Sloan Kettering Cancer Center, New York, New York, United State of America
| | | | - Michael Z. Liu
- Columbia University Medical Center, New York, New York, United State of America
| | | | | | - Jie Zheng
- Washington University in St. Louis, St. Louis, Missouri, United State of America
| | - Peng Hu
- University of California, Los Angeles, California, United State of America
| | - Edward F. Jackson
- University of Wisconsin, Madison, Wisconsin, United State of America
| |
Collapse
|
24
|
Kramer CM, Hanson CA. CMR Parametric Mapping in Immune Checkpoint Inhibitor Myocarditis: Novel Noninvasive Tools in a Lethal Condition. J Am Coll Cardiol 2021; 77:1517-1519. [PMID: 33766257 DOI: 10.1016/j.jacc.2021.01.043] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 01/31/2021] [Indexed: 01/01/2023]
Affiliation(s)
- Christopher M Kramer
- Division of Cardiovascular Medicine, University of Virginia Health System, Charlottesville, Virginia, USA; Department of Radiology, University of Virginia Health System, Charlottesville, Virginia, USA.
| | - Christopher A Hanson
- Division of Cardiovascular Medicine, University of Virginia Health System, Charlottesville, Virginia, USA
| |
Collapse
|