1
|
Wohlgemuth RP, Sriram S, Henricson KE, Dinh DT, Brashear SE, Smith LR. Strain-dependent dynamic re-alignment of collagen fibers in skeletal muscle extracellular matrix. Acta Biomater 2024; 187:227-241. [PMID: 39209134 DOI: 10.1016/j.actbio.2024.08.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2024] [Revised: 08/21/2024] [Accepted: 08/22/2024] [Indexed: 09/04/2024]
Abstract
Collagen fiber architecture within the skeletal muscle extracellular matrix (ECM) is significant to passive muscle mechanics. While it is thought that collagen fibers re-orient themselves in response to changes in muscle length, this has not been dynamically visualized and quantified within a muscle. The goal of this study was to measure changes in collagen alignment across a range of muscle lengths and compare the corresponding alignment to muscle mechanics. We hypothesized that collagen fibers dynamically increase alignment in response to muscle stretching, and this change in alignment is related to passive muscle stiffness. Further, we hypothesized that digesting collagen fibers with collagenase would reduce the re-alignment response to muscle stretching. Using DBA/2J and D2.mdx mice, we isolated extensor digitorum longus (EDL), soleus, and diaphragm muscles for collagenase or sham treatment and decellularization to isolate intact or collagenase-digested decellularized muscles (DCMs). These DCMs were mechanically tested and imaged using second harmonic generation microscopy to measure collagen alignment across a range of strains. We found that collagen alignment increased in a strain-dependent fashion, but collagenase did not significantly affect the strain-dependent change in alignment. We also saw that the collagen fibers in the diaphragm epimysium (surface ECM) and perimysium (deep ECM) started at different angles, but still re-oriented in the same direction in response to stretching. These robust changes in collagen alignment were weakly related to passive DCM stiffness. Overall, we demonstrated that the architecture of muscle ECM is dynamic in response to strain and is related to passive muscle mechanics. STATEMENT OF SIGNIFICANCE: Our study presents a unique visualization and quantification of strain-induced changes in muscle collagen fiber alignment as they relate to passive mechanics. Using dynamic imaging of collagen in skeletal muscle we demonstrate that as skeletal muscle is stretched, collagen fibers re-orient themselves along the axis of stretch and increase their alignment. The degree of alignment and the increase in alignment are each weakly related to passive muscle stiffness. Collagenase treatments further demonstrate that the basis for muscle Extracellular matrix stiffness is dependent on factors beyond collagen crosslinking and alignment. Together the study contributes to the knowledge of the structure-function relationships of muscle extracellular matrix to tissue stiffness relevant to conditions of fibrosis and aberrant stiffness.
Collapse
Affiliation(s)
- Ross P Wohlgemuth
- Department of Neurobiology, Physiology, & Behavior, University of California Davis, United States
| | - Sathvik Sriram
- Department of Neurobiology, Physiology, & Behavior, University of California Davis, United States
| | - Kyle E Henricson
- Department of Neurobiology, Physiology, & Behavior, University of California Davis, United States
| | - Daryl T Dinh
- Department of Neurobiology, Physiology, & Behavior, University of California Davis, United States
| | - Sarah E Brashear
- Department of Neurobiology, Physiology, & Behavior, University of California Davis, United States
| | - Lucas R Smith
- Department of Neurobiology, Physiology, & Behavior, University of California Davis, United States; Department of Physical Medicine and Rehabilitation, University of California Davis, United States.
| |
Collapse
|
2
|
Troop LD, Puetzer JL. Intermittent cyclic stretch of engineered ligaments drives hierarchical collagen fiber maturation in a dose- and organizational-dependent manner. Acta Biomater 2024; 185:296-311. [PMID: 39025395 PMCID: PMC11381169 DOI: 10.1016/j.actbio.2024.07.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 07/10/2024] [Accepted: 07/11/2024] [Indexed: 07/20/2024]
Abstract
Hierarchical collagen fibers are the primary source of strength in tendons and ligaments; however, these fibers largely do not regenerate after injury or with repair, resulting in limited treatment options. We previously developed a static culture system that guides ACL fibroblasts to produce native-sized fibers and early fascicles by 6 weeks. These constructs are promising ligament replacements, but further maturation is needed. Mechanical cues are critical for development in vivo and in engineered tissues; however, the effect on larger fiber and fascicle formation is largely unknown. Our objective was to investigate whether intermittent cyclic stretch, mimicking rapid muscle activity, drives further maturation in our system to create stronger engineered replacements and to explore whether cyclic loading has differential effects on cells at different degrees of collagen organization to better inform engineered tissue maturation protocols. Constructs were loaded with an established intermittent cyclic loading regime at 5 or 10 % strain for up to 6 weeks and compared to static controls. Cyclic loading drove cells to increase hierarchical collagen organization, collagen crimp, and tissue tensile properties, ultimately producing constructs that matched or exceeded immature ACL properties. Further, the effect of loading on cells varied depending on degree of organization. Specifically, 10 % load drove early improvements in tensile properties and composition, while 5 % load was more beneficial later in culture, suggesting a shift in mechanotransduction. This study provides new insight into how cyclic loading affects cell-driven hierarchical fiber formation and maturation, which will help to develop better rehabilitation protocols and engineer stronger replacements. STATEMENT OF SIGNIFICANCE: Collagen fibers are the primary source of strength and function in tendons and ligaments throughout the body. These fibers have limited regenerate after injury, with repair, and in engineered replacements, reducing treatment options. Cyclic load has been shown to improve fibril level alignment, but its effect at the larger fiber and fascicle length-scale is largely unknown. Here, we demonstrate intermittent cyclic loading increases cell-driven hierarchical fiber formation and tissue mechanics, producing engineered replacements with similar organization and mechanics as immature ACLs. This study provides new insight into how cyclic loading affects cell-driven fiber maturation. A better understanding of how mechanical cues regulate fiber formation will help to develop better engineered replacements and rehabilitation protocols to drive repair after injury.
Collapse
Affiliation(s)
- Leia D Troop
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA 23284, United States
| | - Jennifer L Puetzer
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA 23284, United States; Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA 23284, United States.
| |
Collapse
|
3
|
Yoon JP, Kim H, Park SJ, Kim DH, Kim JY, Kim DH, Chung SW. Nanofiber Graft Therapy to Prevent Shoulder Stiffness and Adhesions after Rotator Cuff Tendon Repair: A Comprehensive Review. Biomedicines 2024; 12:1613. [PMID: 39062186 PMCID: PMC11274509 DOI: 10.3390/biomedicines12071613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Revised: 07/09/2024] [Accepted: 07/17/2024] [Indexed: 07/28/2024] Open
Abstract
Stiffness and adhesions following rotator cuff tears (RCTs) are common complications that negatively affect surgical outcomes and impede healing, thereby increasing the risk of morbidity and failure of surgical interventions. Tissue engineering, particularly through the use of nanofiber scaffolds, has emerged as a promising regenerative medicine strategy to address these complications. This review critically assesses the efficacy and limitations of nanofiber-based methods in promoting rotator cuff (RC) regeneration and managing postrepair stiffness and adhesions. It also discusses the need for a multidisciplinary approach to advance this field and highlights important considerations for future clinical trials.
Collapse
Affiliation(s)
- Jong Pil Yoon
- Department of Orthopedic Surgery, School of Medicine, Kyungpook National University, Daegu 41944, Republic of Korea; (J.P.Y.); (S.-J.P.); (D.-H.K.)
| | - Hyunjin Kim
- Department of Orthopedic Surgery, School of Medicine, Kyungpook National University, Daegu 41944, Republic of Korea; (J.P.Y.); (S.-J.P.); (D.-H.K.)
| | - Sung-Jin Park
- Department of Orthopedic Surgery, School of Medicine, Kyungpook National University, Daegu 41944, Republic of Korea; (J.P.Y.); (S.-J.P.); (D.-H.K.)
| | - Dong-Hyun Kim
- Department of Orthopedic Surgery, School of Medicine, Kyungpook National University, Daegu 41944, Republic of Korea; (J.P.Y.); (S.-J.P.); (D.-H.K.)
| | - Jun-Young Kim
- Department of Orthopedic Surgery, School of Medicine, Catholic University, Daegu 38430, Republic of Korea;
| | - Du Han Kim
- Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu 42601, Republic of Korea;
| | - Seok Won Chung
- Department of Orthopedic Surgery, Konkuk University Medical Center, Seoul 05030, Republic of Korea;
| |
Collapse
|
4
|
Böl M, Leichsenring K, Kohn S, Ehret AE. The anisotropic and region-dependent mechanical response of wrap-around tendons under tensile, compressive and combined multiaxial loads. Acta Biomater 2024; 183:157-172. [PMID: 38838908 DOI: 10.1016/j.actbio.2024.05.053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 05/20/2024] [Accepted: 05/30/2024] [Indexed: 06/07/2024]
Abstract
The present work reports on the multiaxial region and orientation-dependent mechanical properties of two porcine wrap-around tendons under tensile, compressive and combined loads based on an extensive study with n=175 samples. The results provide a detailed dataset of the anisotropic tensile and compressive longitudinal properties and document a pronounced tension-compression asymmetry. Motivated by the physiological loading conditions of these tendons, which include transversal compression at bony abutments in addition to longitudinal tension, we systematically investigated the change in axial tension when the tendon is compressed transversally along one or both perpendicular directions. The results reveal that the transversal compression can increase axial tension (proximal-distal direction) in both cases to orders of 30%, yet by a larger amount in the first case (transversal compression in anterior-posterior direction), which seems to be more relevant for wrap-around tendons in-vivo. These quantitative measurements are in line with earlier findings on auxetic properties of tendon tissue, but show for the first time the influence of this property on the stress response of the tendon, and may thus reveal an important functional principle within these essential elements of force transmission in the body. STATEMENT OF SIGNIFICANCE: The work reports for the first time on multiaxial region and orientation-dependent mechanical properties of wrap-around tendons under various loads. The results indicate that differences in the mechanical properties exist between zones that are predominantly in a uniaxial tensile state and those that experience complex load states. The observed counterintuitive increase of the axial tension upon lateral compression points at auxetic properties of the tendon tissue which may be pivotal for the function of the tendon as an element of the musculoskeletal system. It suggests that the tendon's performance in transmitting forces is not diminished but enhanced when the action line is deflected by a bony pulley around which the tendon wraps, representing an important functional principle of tendon tissue.
Collapse
Affiliation(s)
- Markus Böl
- Institute of Mechanics and Adaptronics, Technische Universität Braunschweig, Braunschweig D-38106, Germany.
| | - Kay Leichsenring
- Institute of Mechanics and Adaptronics, Technische Universität Braunschweig, Braunschweig D-38106, Germany
| | - Stephan Kohn
- Institute of Mechanics and Adaptronics, Technische Universität Braunschweig, Braunschweig D-38106, Germany
| | - Alexander E Ehret
- Empa, Swiss Federal Laboratories for Materials Science and Technology, CH-8600 Dübendorf, Switzerland; Institute for Mechanical Systems, ETH Zurich, Zürich, CH-8092, Switzerland
| |
Collapse
|
5
|
Troop LD, Puetzer JL. Intermittent Cyclic Stretch of Engineered Ligaments Drives Hierarchical Collagen Fiber Maturation in a Dose- and Organizational-Dependent Manner. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.04.06.588420. [PMID: 38645097 PMCID: PMC11030411 DOI: 10.1101/2024.04.06.588420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/23/2024]
Abstract
Hierarchical collagen fibers are the primary source of strength in tendons and ligaments, however these fibers do not regenerate after injury or with repair, resulting in limited treatment options. We previously developed a culture system that guides ACL fibroblasts to produce native-sized fibers and fascicles by 6 weeks. These constructs are promising ligament replacements, but further maturation is needed. Mechanical cues are critical for development in vivo and in engineered tissues; however, the effect on larger fiber and fascicle formation is largely unknown. Our objective was to investigate whether intermittent cyclic stretch, mimicking rapid muscle activity, drives further maturation in our system to create stronger engineered replacements and to explore whether cyclic loading has differential effects on cells at different degrees of collagen organization to better inform engineered tissue maturation protocols. Constructs were loaded with an established intermittent cyclic loading regime at 5 or 10% strain for up to 6 weeks and compared to static controls. Cyclic loading drove cells to increase hierarchical collagen organization, collagen crimp, and tissue mechanics, ultimately producing constructs that matched or exceeded immature ACL properties. Further, the effect of loading on cells varied depending on degree of organization. Specifically, 10% load drove early improvements in mechanics and composition, while 5% load was more beneficial later in culture, suggesting a cellular threshold response and a shift in mechanotransduction. This study provides new insight into how cyclic loading affects cell-driven hierarchical fiber formation and maturation, which will help to develop better rehabilitation protocols and engineer stronger replacements.
Collapse
Affiliation(s)
- Leia D. Troop
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA, 23284, United States
| | - Jennifer L. Puetzer
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA, 23284, United States
- Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA, 23284, United States
| |
Collapse
|
6
|
Barrett JM, Callaghan JP. Strain inhibition of bacterial collagenase is consistent with a collagen fibril uncrimping mechanism in rat tail tendons. J Biomech 2024; 162:111892. [PMID: 38061208 DOI: 10.1016/j.jbiomech.2023.111892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 11/23/2023] [Accepted: 11/28/2023] [Indexed: 01/16/2024]
Abstract
Mechanical strain inhibits bacterial collagenase from cleaving collagen. Additionally, the toe region of a soft tissue's force-elongation curve arises from sequentially engaging collagen fibrils as the tissue lengthens. Together, these phenomena suggest that mechanical strain may gradually inhibit collagenase activity through a soft tissue's toe region. Therefore, this investigation sought to test this hypothesis. 92 rat tail tendon fascicles from 3 female sentinel animals underwent preliminary stiffness tests, and their force-elongation curves were fit to a collagen distribution model. This distribution-based model calculated the force magnitude corresponding to p% of collagen fibril engagement. Specimens were separated into one of five levels of p, and that level of force was maintained for two hours while being exposed to 0.054 U/mL of bacterial collagenase from C. histolyticum. The specimens were strained to failure following the creep test, and the relative reduction in stiffness was quantified to estimate the fraction of digested fibrils. Every 10% additional collagen engagement corresponded to a 6.3% (97% highest density interval: 4.3 - 8.4%) retention of stiffness, which indicated collagenase inhibition. The results of this investigation were consistent with a strain-inhibition hypothesis along with the established uncrimping mechanism in the toe region. These results support an interaction between mechanical strain and collagenolysis, which may be valuable for disease prevention or treatment.
Collapse
Affiliation(s)
- Jeff M Barrett
- Department of Kinesiology and Health Sciences, University of Waterloo, Canada.
| | - Jack P Callaghan
- Department of Kinesiology and Health Sciences, University of Waterloo, Canada.
| |
Collapse
|
7
|
Liu S, Al-Danakh A, Wang H, Sun Y, Wang L. Advancements in scaffold for treating ligament injuries; in vitro evaluation. Biotechnol J 2024; 19:e2300251. [PMID: 37974555 DOI: 10.1002/biot.202300251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 11/07/2023] [Accepted: 11/15/2023] [Indexed: 11/19/2023]
Abstract
Tendon/ligament (T/L) injuries are a worldwide health problem that affects millions of people annually. Due to the characteristics of tendons, the natural rehabilitation of their injuries is a very complex and lengthy process. Surgical treatment of a T/L injury frequently necessitates using autologous or allogeneic grafts or synthetic materials. Nonetheless, these alternatives have limitations in terms of mechanical properties and histocompatibility, and they do not permit the restoration of the original biological function of the tissue, which can negatively impact the patient's quality of life. It is crucial to find biological materials that possess the necessary properties for the successful surgical treatment of tissues and organs. In recent years, the in vitro regeneration of tissues and organs from stem cells has emerged as a promising approach for preparing autologous tissue and organs, and cell culture scaffolds play a critical role in this process. However, the biological traits and serviceability of different materials used for cell culture scaffolds vary significantly, which can impact the properties of the cultured tissues. Therefore, this review aims to analyze the differences in the biological properties and suitability of various materials based on scaffold characteristics such as cell compatibility, degradability, textile technologies, fiber arrangement, pore size, and porosity. This comprehensive analysis provides valuable insights to aid in the selection of appropriate scaffolds for in vitro tissue and organ culture.
Collapse
Affiliation(s)
- Shuang Liu
- Department of Urology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Abdullah Al-Danakh
- Department of Urology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Haowen Wang
- Department of Urology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Yuan Sun
- Liaoning Laboratory of Cancer Genomics and Department of Cell Biology, Dalian Medical University, Dalian, China
| | - Lina Wang
- Department of Urology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| |
Collapse
|
8
|
Yang F, Das D, Karunakaran K, Genin GM, Thomopoulos S, Chasiotis I. Nonlinear time-dependent mechanical behavior of mammalian collagen fibrils. Acta Biomater 2023; 163:63-77. [PMID: 35259515 PMCID: PMC9441475 DOI: 10.1016/j.actbio.2022.03.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Revised: 02/16/2022] [Accepted: 03/02/2022] [Indexed: 11/01/2022]
Abstract
The viscoelastic mechanical behavior of collagenous tissues has been studied extensively at the macroscale, yet a thorough quantitative understanding of the time-dependent mechanics of the basic building blocks of tissues, the collagen fibrils, is still missing. In order to address this knowledge gap, stress relaxation and creep tests at various stress (5-35 MPa) and strain (5-20%) levels were performed with individual collagen fibrils (average diameter of fully hydrated fibrils: 253 ± 21 nm) in phosphate buffered saline (PBS). The experimental results showed that the time-dependent mechanical behavior of fully hydrated individual collagen fibrils reconstituted from Type I calf skin collagen, is described by strain-dependent stress relaxation and stress-dependent creep functions in both the heel-toe and the linear regimes of deformation in monotonic stress-strain curves. The adaptive quasilinear viscoelastic (QLV) model, originally developed to capture the nonlinear viscoelastic response of collagenous tissues, provided a very good description of the nonlinear stress relaxation and creep behavior of the collagen fibrils. On the other hand, the nonlinear superposition (NSP) model fitted well the creep but not the stress relaxation data. The time constants and rates extracted from the adaptive QLV and the NSP models, respectively, pointed to a faster rate for stress relaxation than creep. This nonlinear viscoelastic behavior of individual collagen fibrils agrees with prior studies of macroscale collagenous tissues, thus demonstrating consistent time-dependent behavior across length scales and tissue hierarchies. STATEMENT OF SIGNIFICANCE: Pure stress relaxation and creep experiments were conducted for the first time with fully hydrated individual collagen fibrils. It is shown that collagen nanofibrils have a nonlinear time-dependent behavior which agrees with prior studies on macroscale collagenous tissues, thus demonstrating consistent time-dependent behavior across length scales and tissue hierarchies. This new insight into the non-linear viscoelastic behavior of the building blocks of mammalian collagenous tissues may serve as the foundation for improved macroscale tissue models that capture the mechanical behavior across length scales.
Collapse
Affiliation(s)
- Fan Yang
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Debashish Das
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Kathiresan Karunakaran
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Guy M Genin
- Mechanical Engineering and Materials Science, Washington University, St. Louis, MO 63130, USA
| | - Stavros Thomopoulos
- Orthopedic Surgery, Biomedical Engineering, Columbia University, New York, NY 10032, USA
| | - Ioannis Chasiotis
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
| |
Collapse
|
9
|
Single collagen fibrils isolated from high stress and low stress tendons show differing susceptibility to enzymatic degradation by the interstitial collagenase matrix metalloproteinase-1 (MMP-1). Matrix Biol Plus 2023; 18:100129. [PMID: 36915648 PMCID: PMC10006499 DOI: 10.1016/j.mbplus.2023.100129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 02/10/2023] [Accepted: 02/20/2023] [Indexed: 02/25/2023] Open
Abstract
Bovine forelimb flexor and extensor tendons serve as a model for examining high stress, energy storing and low stress, positional tendons, respectively. Previous research has shown structural differences between the collagen fibrils of these tissues. The nanoscale collagen fibrils of flexor tendons are smaller in size, more heavily crosslinked, and respond differently to mechanical loading. Meanwhile, energy storing tendons undergo less collagen turnover compared to positional tendons and are more commonly injured. These observations raise the question of whether collagen fibril structure influences the collagen degradation processes necessary for remodelling. Atomic force microscopy was used to image dry collagen fibrils before and after 5-hour exposure to matrix metalloproteinase-1 (MMP-1) to detect changes in fibril size. Collagen fibrils from three tissue types were studied: bovine superficial digital flexor tendons, matched-pair bovine lateral digital extensor tendons, and rat tail tendons. Compared to control fibrils exposed only to buffer, a significant decrease in fibril cross-sectional area (CSA) following MMP-1 exposure was observed for bovine extensor and rat tail fibrils, with larger fibrils experiencing a greater magnitude of CSA decrease in both fibril types. Fibrils from bovine flexor tendons, on the other hand, showed no decrease in CSA when exposed to MMP-1. The result did not appear to be linked to the small size of flexor fibrils, as equivalently sized extensor fibrils were readily degraded by the enzyme. Increased proteolytic resistance of collagen fibrils from high stress tendons may help to explain the longevity of collagen within these tissues in vivo.
Collapse
|
10
|
Ostadi Moghaddam A, Arshee MR, Lin Z, Sivaguru M, Phillips H, McFarlin BL, Toussaint KC, Wagoner Johnson AJ. An indentation-based framework for probing the glycosaminoglycan-mediated interactions of collagen fibrils. J Mech Behav Biomed Mater 2023; 140:105726. [PMID: 36827935 PMCID: PMC10061372 DOI: 10.1016/j.jmbbm.2023.105726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 02/01/2023] [Accepted: 02/11/2023] [Indexed: 02/17/2023]
Abstract
Microscale deformation processes, such as reorientation, buckling, and sliding of collagen fibrils, determine the mechanical behavior and function of collagenous tissue. While changes in the structure and composition of tendon have been extensively studied, the deformation mechanisms that modulate the interaction of extracellular matrix (ECM) constituents are not well understood, partly due to the lack of appropriate techniques to probe the behavior. In particular, the role of glycosaminoglycans (GAGs) in modulating collagen fibril interactions has remained controversial. Some studies suggest that GAGs act as crosslinkers between the collagen fibrils, while others have not found such evidence and postulate that GAGs have other functions. Here, we introduce a new framework, relying on orientation-dependent indentation behavior of tissue and computational modeling, to evaluate the shear-mediated function of GAGs in modulating the collagen fibril interactions at a length scale more relevant to fibrils compared to bulk tests. Specifically, we use chondroitinase ABC to enzymatically deplete the GAGs in tendon; measure the orientation-dependent indentation response in transverse and longitudinal orientations; and infer the microscale deformation mechanisms and function of GAGs from a microstructural computational model and a modified shear-lag model. We validate the modeling approach experimentally and show that GAGs facilitate collagen fibril sliding with minimal crosslinking function. We suggest that the molecular reconfiguration of GAGs is a potential mechanism for their microscale, strain-dependent viscoelastic behavior. This study reveals the mechanisms that control the orientation-dependent indentation response by affecting the shear deformation and provides new insights into the mechanical function of GAGs and collagen crosslinkers in collagenous tissue.
Collapse
Affiliation(s)
- A Ostadi Moghaddam
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA; Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - M R Arshee
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Z Lin
- School of Engineering, Brown University, Providence, RI, 02912, USA
| | - M Sivaguru
- Flow Cytometry and Microscopy to Omics, Roy J. Carver Biotechnology Center, University of Illinois at Urbana-Champaign, Champaign, IL, 61820, USA
| | - H Phillips
- Department of Veterinary Clinical Medicine, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - B L McFarlin
- Department of Women, Children and Family Health Science, University of Illinois College of Nursing, Chicago, IL, 60612, USA
| | - K C Toussaint
- School of Engineering, Brown University, Providence, RI, 02912, USA
| | - A J Wagoner Johnson
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA; Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA; Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Champaign, IL, 61820, USA; Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
| |
Collapse
|
11
|
Tavakol M, Vaughan TJ. A coarse-grained molecular dynamics investigation of the role of mineral arrangement on the mechanical properties of mineralized collagen fibrils. J R Soc Interface 2023; 20:20220803. [PMID: 36695019 PMCID: PMC9874270 DOI: 10.1098/rsif.2022.0803] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Accepted: 12/16/2022] [Indexed: 01/26/2023] Open
Abstract
Mineralized collagen fibrils (MCFs) comprise collagen molecules and hydroxyapatite (HAp) crystals and are considered universal building blocks of bone tissue, across different bone types and species. In this study, we developed a coarse-grained molecular dynamics (CGMD) framework to investigate the role of mineral arrangement on the load-deformation behaviour of MCFs. Despite the common belief that the collagen molecules are responsible for flexibility and HAp minerals are responsible for stiffness, our results showed that the mineral phase was responsible for limiting collagen sliding in the large deformation regime, which helped the collagen molecules themselves undergo high tensile loading, providing a substantial contribution to the ultimate tensile strength of MCFs. This study also highlights different roles for the mineralized and non-mineralized protofibrils within the MCF, with the mineralized groups being primarily responsible for load carrying due to the presence of the mineral phase, while the non-mineralized groups are responsible for crack deflection. These results provide novel insight into the load-deformation behaviour of MCFs and highlight the intricate role that both collagen and mineral components have in dictating higher scale bone biomechanics.
Collapse
Affiliation(s)
- Mahdi Tavakol
- Biomedical Engineering and Biomechanics Research Centre, School of Engineering, College of Science and Engineering, University of Galway, Galway, Ireland
| | - Ted J. Vaughan
- Biomedical Engineering and Biomechanics Research Centre, School of Engineering, College of Science and Engineering, University of Galway, Galway, Ireland
| |
Collapse
|
12
|
Andriotis OG, Nalbach M, Thurner PJ. Mechanics of isolated individual collagen fibrils. Acta Biomater 2022; 163:35-49. [PMID: 36509398 DOI: 10.1016/j.actbio.2022.12.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 11/15/2022] [Accepted: 12/05/2022] [Indexed: 12/13/2022]
Abstract
Collagen fibrils are the fundamental structural elements in vertebrate animals and compose a framework that provides mechanical support to load-bearing tissues. Understanding how these fibrils initially form and mechanically function has been the focus of a myriad of detailed investigations over the last few decades. From these studies a great amount of knowledge has been acquired as well as a number of new questions to consider. In this review, we examine the current state of our knowledge of the mechanical properties of extant fibrils. We emphasize on the mechanical response and related deformation of collagen fibrils upon tension, which is the predominant load imposed in most collagen-rich tissues. We also illuminate the gaps in knowledge originating from the intriguing results that the field is still trying to interpret. STATEMENT OF SIGNIFICANCE: : Collagen is the result of millions of years of biological evolution and is a unique family of proteins, the majority of which provide mechanical support to biological tissues. Cells produce collagen molecules that self-assemble into larger structures, known as collagen fibrils. As simple as they appear under an optical microscope, collagen fibrils display a complex ultrastructural architecture tuned to the external forces that are imposed upon them. Even more complex is the way collagen fibrils deform under loading, and the nature of the mechanisms that drive their formation in the first place. Here, we present a cogent synthesis of the state-of-knowledge of collagen fibril mechanics. We focus on the information we have from in vitro experiments on individual, isolated from tissues, collagen fibrils and the knowledge available from in silico tests.
Collapse
Affiliation(s)
- Orestis G Andriotis
- Institute for Lightweight Design and Structural Biomechanics, TU Wien, Vienna, A-1060, Austria
| | - Mathis Nalbach
- Institute for Lightweight Design and Structural Biomechanics, TU Wien, Vienna, A-1060, Austria
| | - Philipp J Thurner
- Institute for Lightweight Design and Structural Biomechanics, TU Wien, Vienna, A-1060, Austria.
| |
Collapse
|
13
|
Chen W, Zhou Q. Opposite Effect of Cyclic Loading on the Material Properties of Medial Collateral Ligament at Different Temperatures: An Animal Study. Front Bioeng Biotechnol 2022; 10:925033. [PMID: 35774057 PMCID: PMC9237215 DOI: 10.3389/fbioe.2022.925033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Accepted: 05/23/2022] [Indexed: 11/13/2022] Open
Abstract
In traffic accidents, the medial collateral ligament (MCL) injury of the knee joint of pedestrians is common. Biofidelic material is important to realize MCL's native biomechanics in simulations to clarify the injury mechanisms of pedestrians. Pedestrians' MCLs usually experience cyclic loading at the intra-articular temperature of the knee joint before accidents. Temperature influences the material behaviors of ligaments. However, the mechanical properties of ligaments under cyclic loading have been widely evaluated only at room temperature rather than physiological temperature. Therefore, this study aimed to determine whether the difference between room and intra-articular temperatures influences the effect of cyclic loading on the mechanical properties of MCL. We measured the tensile properties of 34 porcine MCLs at room temperature (21-23°C) and intra-articular temperature (35-37°C), with either 10 cycles or 240 cycles of cyclic loading, a total of four different conditions. The structural responses and geometric data were recorded. After 240 cycles of cyclic loading, stiffness increased by 29.0% (p < 0.01) at room temperature and decreased by 11.5% (p = 0.106) at intra-articular temperature. Material properties were further compared because the geometric differences between samples were inevitable. At room temperature, after 240 cycles of cyclic loading, elastic modulus increased by 29.6% (p < 0.001), and failure strain decreased by 20.4% (p < 0.05). By contrast, at intra-articular temperature, after 240 cycles of cyclic loading, modulus decreased by 27.4% (p < 0.001), and failure strain increased by 17.5% (p = 0.193), insignificant though. In addition, there were no significant differences between the four groups in other structural or material properties. The results showed that temperature reversed the effect of cyclic loading on the mechanical properties of MCL, which may be caused by the high strength and thermally stable crosslinks of MCL. Therefore, for improving the fidelity of knee joint simulations and elucidating the injury mechanism of pedestrians, it is better to measure the mechanical properties of MCL at intra-articular temperature rather than room temperature.
Collapse
Affiliation(s)
| | - Qing Zhou
- State Key Laboratory of Automotive Safety and Energy, School of Vehicle and Mobility, Tsinghua University, Beijing, China
| |
Collapse
|
14
|
Haughton J, Cotter SL, Parnell WJ, Shearer T. Bayesian inference on a microstructural, hyperelastic model of tendon deformation. J R Soc Interface 2022; 19:20220031. [PMID: 35582809 PMCID: PMC9114946 DOI: 10.1098/rsif.2022.0031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 04/25/2022] [Indexed: 11/30/2022] Open
Abstract
Microstructural models of soft-tissue deformation are important in applications including artificial tissue design and surgical planning. The basis of these models, and their advantage over their phenomenological counterparts, is that they incorporate parameters that are directly linked to the tissue's microscale structure and constitutive behaviour and can therefore be used to predict the effects of structural changes to the tissue. Although studies have attempted to determine such parameters using diverse, state-of-the-art, experimental techniques, values ranging over several orders of magnitude have been reported, leading to uncertainty in the true parameter values and creating a need for models that can handle such uncertainty. We derive a new microstructural, hyperelastic model for transversely isotropic soft tissues and use it to model the mechanical behaviour of tendons. To account for parameter uncertainty, we employ a Bayesian approach and apply an adaptive Markov chain Monte Carlo algorithm to determine posterior probability distributions for the model parameters. The obtained posterior distributions are consistent with parameter measurements previously reported and enable us to quantify the uncertainty in their values for each tendon sample that was modelled. This approach could serve as a prototype for quantifying parameter uncertainty in other soft tissues.
Collapse
Affiliation(s)
- James Haughton
- Department of Mathematics, University of Manchester, Manchester M13 9PL, UK
| | - Simon L. Cotter
- Department of Mathematics, University of Manchester, Manchester M13 9PL, UK
| | - William J. Parnell
- Department of Mathematics, University of Manchester, Manchester M13 9PL, UK
| | - Tom Shearer
- Department of Mathematics, University of Manchester, Manchester M13 9PL, UK
- Department of Materials, University of Manchester, Manchester M13 9PL, UK
| |
Collapse
|
15
|
Bose S, Li S, Mele E, Silberschmidt VV. Exploring the Mechanical Properties and Performance of Type-I Collagen at Various Length Scales: A Progress Report. MATERIALS 2022; 15:ma15082753. [PMID: 35454443 PMCID: PMC9025246 DOI: 10.3390/ma15082753] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 04/04/2022] [Accepted: 04/06/2022] [Indexed: 12/30/2022]
Abstract
Collagen is the basic protein of animal tissues and has a complex hierarchical structure. It plays a crucial role in maintaining the mechanical and structural stability of biological tissues. Over the years, it has become a material of interest in the biomedical industries thanks to its excellent biocompatibility and biodegradability and low antigenicity. Despite its significance, the mechanical properties and performance of pure collagen have been never reviewed. In this work, the emphasis is on the mechanics of collagen at different hierarchical levels and its long-term mechanical performance. In addition, the effect of hydration, important for various applications, was considered throughout the study because of its dramatic influence on the mechanics of collagen. Furthermore, the discrepancies in reports of the mechanical properties of collagenous tissues (basically composed of 20-30% collagen fibres) and those of pure collagen are discussed.
Collapse
Affiliation(s)
- Shirsha Bose
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough LE11 3TU, Leicestershire, UK; (S.B.); (S.L.)
| | - Simin Li
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough LE11 3TU, Leicestershire, UK; (S.B.); (S.L.)
| | - Elisa Mele
- Department of Materials, Loughborough University, Loughborough LE11 3TU, Leicestershire, UK
- Correspondence: (E.M.); (V.V.S.)
| | - Vadim V. Silberschmidt
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough LE11 3TU, Leicestershire, UK; (S.B.); (S.L.)
- Laboratory of Mechanics of Biocompatible Materials and Devices, Perm National Research Polytechnic University, 614990 Perm, Russia
- Correspondence: (E.M.); (V.V.S.)
| |
Collapse
|
16
|
Mechanical properties of human patellar tendon collagen fibrils. An exploratory study of aging and sex. J Mech Behav Biomed Mater 2021; 124:104864. [PMID: 34607298 DOI: 10.1016/j.jmbbm.2021.104864] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 08/31/2021] [Accepted: 09/26/2021] [Indexed: 02/05/2023]
Abstract
Tendons are connective tissues that transmit mechanical forces from muscle to bone and consist mainly of nano-scale fibrils of type I collagen. Aging has been associated with reduced mechanical function of tendons at the whole-tendon level and also with increased glycation of tendon collagen fibrils. Yet, the mechanical effects of aging at the fibril level remain unknown. In vitro glycation has previously been reported to substantially increase fibril strength and stiffness in young rats, suggesting a potentially large effect of aging through the glycation mechanism. We therefore expected that aging would have a similar major impact on fibril mechanical properties. In addition, differences in fibril mechanical properties between men and women have never been studied. This study investigated human patellar tendon biopsies from young (26 ± 4 years) and elderly (66 ± 1 years), men and women by measuring the mechanical properties of individual collagen fibrils using a custom nano-mechanical device. There were no major mechanical differences with either age or sex, but there were modestly greater failure stress (22%) and tensile modulus at both low and high strain (16% and 26% respectively) in the elderly group. No significant differences in mechanical properties were observed between men and women. The slightly greater strength and stiffness in the elderly group are in contrasts to the age-related deficits observed for whole-tendons in vivo, although the study was not designed to investigate these minor differences.
Collapse
|
17
|
Bennett K, Vincent T, Sakthi-Velavan S. The patellar ligament: A comprehensive review. Clin Anat 2021; 35:52-64. [PMID: 34554600 DOI: 10.1002/ca.23791] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Revised: 09/15/2021] [Accepted: 09/17/2021] [Indexed: 01/25/2023]
Abstract
The patellar ligament (PL) is an epiphyseal ligament and is part of the extensor complex of the knee. The ligament has gained attention due to its clinical relevance to autograft and tendinopathy. A variety of anatomical variations of the PL such as aplasia, numerical variations, and vascularity are being reported recently by clinicians and anatomists. The aim of this literature was to review the available literature to provide a consensus regarding anatomic variations of the PL, neurovasculature surrounding the PL, histology of the PL, and various aspects of PL measurements with relevance to the surgical considerations and sex and age-related differences. A narrative review of the patellar ligament was performed by conducting a detailed literature search and review of relevant articles. A total of 90 articles on the patellar ligament were included and were categorized into studies based on anatomical variations, neurovasculature, morphometrics, microanatomy, sex and age-related difference, and ACL reconstruction. The anatomical variations and morphometrics of the PL were found to correlate with the frequency of strain injuries, tendinopathy, and efficacy of the PL autograft in anterior cruciate ligament reconstruction. The sex differences in PL measurements and the effect of estrogen on collagen synthesis explained a higher incidence of patellar tendinopathy in women. An awareness of its variations enables careful selection of surgical incisions, thereby avoiding complications related to nerve injury. Accurate knowledge of the PL microanatomy assists in understanding the mechanism of ligament degeneration, rupture, autograft harvesting, and ligamentization results.
Collapse
Affiliation(s)
- Karis Bennett
- Division of Biomedical Sciences, Marian University College of Osteopathic Medicine, Indianapolis, Indiana, USA
| | - Tanner Vincent
- Division of Biomedical Sciences, Marian University College of Osteopathic Medicine, Indianapolis, Indiana, USA
| | - Sumathilatha Sakthi-Velavan
- Division of Biomedical Sciences, Marian University College of Osteopathic Medicine, Indianapolis, Indiana, USA
| |
Collapse
|
18
|
Pineda Guzman RA, Kersh ME. Replication of the tensile behavior of knee ligaments using architected acrylic yarn. J Mech Behav Biomed Mater 2021; 118:104339. [PMID: 33744501 DOI: 10.1016/j.jmbbm.2021.104339] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 12/18/2020] [Accepted: 01/15/2021] [Indexed: 10/21/2022]
Abstract
Knee ligament injury diagnosis is achieved by a comparison between the laxity levels sensed by a clinician in the injured and healthy limb. This is a difficult-to-learn task that requires hands-on practice to achieve proficiency. The inclusion of a physical knee simulator with biomechanically realistic passive components such as knee ligaments could provide consistent training for medical students and lead to improved care for knee injury patients. In this study, we developed a material construct that is both adaptable to a physical knee model and capable of replicating the non-linear mechanical behavior of knee ligaments with the use of helically arranged acrylic yarn. The microstructure of four different types of acrylic yarn were measured and then tested under uniaxial tension. While the fiber twist angle was similar amongst the four yarn types (range = 17.9-18.8°), one yarn was distinct with a low ply twist angle (15.2 ± 1.6°) and high packing fraction (Φ=0.32±0.08). These microstructural differences yielded a lower toe length and higher stiffness and best corresponded to ligament mechanical behavior. We then made looped-yarn constructs to modulate the sample's toe length and stiffness. We found that the load-displacement curve of the construct can be tuned by changing the loop length and loop number of the looped-yarn constructs, matching the load-displacement curve of specific knee ligaments. This study shows how spun yarn can be used to replicate the mechanical behavior of knee ligaments, creating synthetic ligament constructs that could enable the construction of biomechanically realistic joints.
Collapse
Affiliation(s)
- Roberto A Pineda Guzman
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, United States
| | - Mariana E Kersh
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, United States; Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, United States.
| |
Collapse
|
19
|
Siadat SM, Silverman AA, DiMarzio CA, Ruberti JW. Measuring collagen fibril diameter with differential interference contrast microscopy. J Struct Biol 2021; 213:107697. [PMID: 33545351 DOI: 10.1016/j.jsb.2021.107697] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Revised: 12/04/2020] [Accepted: 01/12/2021] [Indexed: 02/01/2023]
Abstract
Collagen fibrils, linear arrangements of collagen monomers, 20-500 nm in diameter, comprising hundreds of molecules in their cross-section, are the fundamental structural unit in a variety of load-bearing tissues such as tendons, ligaments, skin, cornea, and bone. These fibrils often assemble into more complex structures, providing mechanical stability, strength, or toughness to the host tissue. Unfortunately, there is little information available on individual fibril dynamics, mechanics, growth, aggregation and remodeling because they are difficult to image using visible light as a probe. The principle quantity of interest is the fibril diameter, which is difficult to extract accurately, dynamically, in situ and non-destructively. An optical method, differential interference contrast (DIC) microscopy has been used to visualize dynamic structures that are as small as microtubules (25 nm diameter) and has been shown to be sensitive to the size of objects smaller than the wavelength of light. In this investigation, we take advantage of DIC microscopy's ability to report dimensions of nanometer scale objects to generate a curve that relates collagen diameter to DIC edge intensity shift (DIC-EIS). We further calibrate the curve using electron microscopy and demonstrate a linear correlation between fibril diameter and the DIC-EIS. Using a non-oil immersion, 40x objective (NA 0.6), collagen fibril diameters between ~100 nm to ~ 300 nm could be obtained with ±11 and ±4 nm accuracy for dehydrated and hydrated fibrils, respectively. This simple, nondestructive, label free method should advance our ability to directly examine fibril dynamics under experimental conditions that are physiologically relevant.
Collapse
Affiliation(s)
| | | | - Charles A DiMarzio
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA 02115, USA
| | - Jeffrey W Ruberti
- Department of Bioengineering, Northeastern University, Boston, MA 02115, USA.
| |
Collapse
|
20
|
Puetzer JL, Ma T, Sallent I, Gelmi A, Stevens MM. Driving Hierarchical Collagen Fiber Formation for Functional Tendon, Ligament, and Meniscus Replacement. Biomaterials 2021; 269:120527. [PMID: 33246739 PMCID: PMC7883218 DOI: 10.1016/j.biomaterials.2020.120527] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 10/09/2020] [Accepted: 11/03/2020] [Indexed: 12/22/2022]
Abstract
Hierarchical collagen fibers are the primary source of strength in musculoskeletal tendons, ligaments, and menisci. It has remained a challenge to develop these large fibers in engineered replacements or in vivo after injury. The objective of this study was to investigate the ability of restrained cell-seeded high density collagen gels to drive hierarchical fiber formation for multiple musculoskeletal tissues. We found boundary conditions applied to high density collagen gels were capable of driving tenocytes, ligament fibroblasts, and meniscal fibrochondrocytes to develop native-sized hierarchical collagen fibers 20-40 μm in diameter. The fibers organize similar to bovine juvenile collagen with native fibril banding patterns and hierarchical fiber bundles 50-350 μm in diameter by 6 weeks. Mirroring fiber organization, tensile properties of restrained samples improved significantly with time, reaching ~1 MPa. Additionally, tendon, ligament, and meniscal cells produced significantly different sized fibers, different degrees of crimp, and different GAG concentrations, which corresponded with respective juvenile tissue. To our knowledge, these are some of the largest, most organized fibers produced to date in vitro. Further, cells produced tissue specific hierarchical fibers, suggesting this system is a promising tool to better understand cellular regulation of fiber formation to better stimulate it in vivo after injury.
Collapse
Affiliation(s)
- Jennifer L Puetzer
- Department of Materials, Department of Bioengineering, And Institute for Biomedical Engineering, Imperial College London, London, United Kingdom, SW7 2AZ; Department of Biomedical Engineering and Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA, United States, 23284.
| | - Tianchi Ma
- Department of Materials, Department of Bioengineering, And Institute for Biomedical Engineering, Imperial College London, London, United Kingdom, SW7 2AZ
| | - Ignacio Sallent
- Department of Materials, Department of Bioengineering, And Institute for Biomedical Engineering, Imperial College London, London, United Kingdom, SW7 2AZ
| | - Amy Gelmi
- Department of Materials, Department of Bioengineering, And Institute for Biomedical Engineering, Imperial College London, London, United Kingdom, SW7 2AZ
| | - Molly M Stevens
- Department of Materials, Department of Bioengineering, And Institute for Biomedical Engineering, Imperial College London, London, United Kingdom, SW7 2AZ.
| |
Collapse
|
21
|
Ristaniemi A, Tanska P, Stenroth L, Finnilä MAJ, Korhonen RK. Comparison of material models for anterior cruciate ligament in tension: from poroelastic to a novel fibril-reinforced nonlinear composite model. J Biomech 2020; 114:110141. [PMID: 33302181 DOI: 10.1016/j.jbiomech.2020.110141] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Revised: 11/05/2020] [Accepted: 11/12/2020] [Indexed: 12/15/2022]
Abstract
Computational models of the knee joint are useful for evaluating stresses and strains within the joint tissues. However, the outcome of those models is sensitive to the material model and material properties chosen for ligaments, the collagen reinforced tissues connecting bone to bone. The purpose of this study was to investigate different compositionally motivated material models and further to develop a model that can accurately reproduce experimentally measured stress-relaxation data of bovine anterior cruciate ligament (ACL). Tensile testing samples were extracted from ACLs of bovine knee joints (N = 10) and subjected to a three-step stress-relaxation test at the toe region. Data from the experiments was averaged and one average finite element model was generated to replicate the experiment. Poroelastic and different fibril-reinforced poro(visco)elastic material models were applied, and their material parameters were optimized to reproduce the experimental force-time response. Material models with only fluid flow mediated relaxation were not able to capture the stress-relaxation behavior (R2 = 0.806, 0.803 and 0.938). The inclusion of the viscoelasticity of the fibrillar network improved the model prediction (R2 = 0.978 and 0.976), but the complex stress-relaxation behavior was best captured by a poroelastic model with a nonlinear two-relaxation-time strain-recruited viscoelastic fibrillar network (R2 = 0.997). The results suggest that in order to replicate the multi-step stress-relaxation behavior of ACL in tension, the fibrillar network formulation should include the complex nonlinear viscoelastic phenomena.
Collapse
Affiliation(s)
- A Ristaniemi
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.
| | - P Tanska
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - L Stenroth
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - M A J Finnilä
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, Oulu, Finland
| | - R K Korhonen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
22
|
Peterson BE, Szczesny SE. Dependence of tendon multiscale mechanics on sample gauge length is consistent with discontinuous collagen fibrils. Acta Biomater 2020; 117:302-309. [PMID: 33010516 DOI: 10.1016/j.actbio.2020.09.046] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 09/22/2020] [Accepted: 09/24/2020] [Indexed: 12/27/2022]
Abstract
While collagen fibrils are understood to be the primary load-bearing elements in tendon, controversy still exists on how fibrils functionally transmit load from muscle to bone. Specifically, it's unclear whether fibrils are structurally continuous along the tendon length and bear load independently, or if they are discontinuous and transfer load through interfibrillar shear forces. To address this question, we investigated whether the multiscale mechanics of rat tail tendon fascicles is dependent on sample gauge length. We hypothesized that as the grip-to-grip length is reduced and approaches the length of the collagen fibrils, tendon fascicles will adopt a multiscale mechanical response consistent with structurally continuous fibrils. Our findings show that, for gauge lengths of 20 mm or greater, the local fibril strains are less than the bulk tissue strains, which can be explained by relative sliding between discontinuous collagen fibrils. In contrast, at a 5 mm gauge length, the fibril strains are equivalent to the applied tissue strains, suggesting that the collagen fibrils are structurally continuous between the grips. Additionally, the macroscale tissue modulus is increased at gauge lengths of 5 and 10 mm. Together, these data support the hypothesis that collagen fibrils in rat tail tendon fascicles are discontinuous and also suggest that their length is between 5 and 10 mm. This fundamental information regarding tendon structure-function relationships underscores the importance of the tissue components that transmit load between fibrils and is critical for understanding tendon pathology as well as establishing structural benchmarks for suitable tissue engineered replacements.
Collapse
|
23
|
Ristaniemi A, Torniainen J, Stenroth L, Finnilä M, Paakkonen T, Töyräs J, Korhonen R. Comparison of water, hydroxyproline, uronic acid and elastin contents of bovine knee ligaments and patellar tendon and their relationships with biomechanical properties. J Mech Behav Biomed Mater 2020; 104:103639. [DOI: 10.1016/j.jmbbm.2020.103639] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 01/13/2020] [Accepted: 01/13/2020] [Indexed: 12/13/2022]
|
24
|
Adams S, Wuescher LM, Worth R, Yildirim-Ayan E. Mechano-Immunomodulation: Mechanoresponsive Changes in Macrophage Activity and Polarization. Ann Biomed Eng 2019; 47:2213-2231. [PMID: 31218484 PMCID: PMC7043232 DOI: 10.1007/s10439-019-02302-4] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Accepted: 06/07/2019] [Indexed: 12/31/2022]
Abstract
In recent years, biomaterial- and scaffold-based immunomodulation strategies were implemented in tissue regeneration efforts for manipulating macrophage polarization (a.k.a. phenotype or lineage commitment, or differentiation). Yet, most of our understanding of macrophage phenotype commitment and phagocytic capacity is limited to how physical cues (extracellular matrix stiffness, roughness, and topography) and soluble chemical cues (cytokines and chemokines released from the scaffold) influence macrophage polarization. In the context of immune response-tissue interaction, the mechanical cues experienced by the residing cells within the tissue also play a critical role in macrophage polarization and inflammatory response. However, there is no compiled study discussing the effect of the dynamic mechanical environment around the tissues on macrophage polarization and the innate immune response. The aim of this comprehensive review paper is 2-fold; (a) to highlight the importance of mechanical cues on macrophage lineage commitment and function and (b) to summarize the important studies dedicated to understand how macrophage polarization changes with different mechanical loading modalities. For the first time, this review paper compiles and compartmentalizes the studies investigating the role of dynamic mechanical loading with various modalities, amplitude, and frequency on macrophage differentiation. A deeper understanding of macrophage phenotype in mechanically dominant tissues (i.e. musculoskeletal tissues, lung tissues, and cardiovascular tissues) provides mechanistic insights into the design of mechano-immunomodulatory tissue scaffold for tissue regeneration.
Collapse
Affiliation(s)
- Sarah Adams
- Department of Bioengineering, College of Engineering, University of Toledo, Toledo, OH, 43606, USA
| | - Leah M Wuescher
- Department of Medical Microbiology and Immunology, University of Toledo College of Medicine and Life Sciences, Toledo, OH, 43614, USA
| | - Randall Worth
- Department of Medical Microbiology and Immunology, University of Toledo College of Medicine and Life Sciences, Toledo, OH, 43614, USA
| | - Eda Yildirim-Ayan
- Department of Bioengineering, College of Engineering, University of Toledo, Toledo, OH, 43606, USA.
- Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, OH, 43614, USA.
| |
Collapse
|
25
|
Baldwin M, Snelling S, Dakin S, Carr A. Augmenting endogenous repair of soft tissues with nanofibre scaffolds. J R Soc Interface 2019; 15:rsif.2018.0019. [PMID: 29695606 DOI: 10.1098/rsif.2018.0019] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Accepted: 04/04/2018] [Indexed: 12/21/2022] Open
Abstract
As our ability to engineer nanoscale materials has developed we can now influence endogenous cellular processes with increasing precision. Consequently, the use of biomaterials to induce and guide the repair and regeneration of tissues is a rapidly developing area. This review focuses on soft tissue engineering, it will discuss the types of biomaterial scaffolds available before exploring physical, chemical and biological modifications to synthetic scaffolds. We will consider how these properties, in combination, can provide a precise design process, with the potential to meet the requirements of the injured and diseased soft tissue niche. Finally, we frame our discussions within clinical trial design and the regulatory framework, the consideration of which is fundamental to the successful translation of new biomaterials.
Collapse
Affiliation(s)
- Mathew Baldwin
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
| | - Sarah Snelling
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
| | - Stephanie Dakin
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
| | - Andrew Carr
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
| |
Collapse
|
26
|
Bojsen-Møller J, Magnusson SP. Mechanical properties, physiological behavior, and function of aponeurosis and tendon. J Appl Physiol (1985) 2019; 126:1800-1807. [DOI: 10.1152/japplphysiol.00671.2018] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
During human movement, the muscle and tendinous structures interact as a mechanical system in which forces are generated and transmitted to the bone and energy is stored and released to optimize function and economy of movement and/or to reduce risk of injury. The present review addresses certain aspects of how the anatomical design and mechanical and material properties of the force-transmitting tissues contribute to the function of the muscle-tendon unit and thus overall human function. The force-bearing tissues are examined from a structural macroscopic point of view down to the nanoscale level of the collagen fibril. In recent years, the understanding of in vivo mechanical function of the force-bearing tissues has increased, and it has become clear that these tissues adapt to loading and unloading and furthermore that force transmission mechanics is more complex than previously thought. Future investigations of the force-transmitting tissues in three dimensions will enable a greater understanding of the complex functional interplay between muscle and tendon, with relevance for performance, injury mechanisms, and rehabilitation strategies.
Collapse
Affiliation(s)
- Jens Bojsen-Møller
- Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark
- Section for Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - S. Peter Magnusson
- Institute of Sports Medicine, Department of Orthopaedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
- Department of Occupational and Physical Therapy, Bispebjerg Hospital, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
27
|
Karathanasopoulos N, Ganghoffer JF. Exploiting Viscoelastic Experimental Observations and Numerical Simulations to Infer Biomimetic Artificial Tendon Fiber Designs. Front Bioeng Biotechnol 2019; 7:85. [PMID: 31134193 PMCID: PMC6513967 DOI: 10.3389/fbioe.2019.00085] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Accepted: 04/05/2019] [Indexed: 11/18/2022] Open
Abstract
Designing biomimetic artificial tendons requires a thorough, data-based understanding of the tendon's inner material properties. The current work exploits viscoelastic experimental observations at the tendon fascicle scale, making use of mechanical and data analysis methods. More specifically, based on reported elastic, volumetric and relaxation fascicle scale properties, we infer most probable, mechanically compatible material attributes at the fiber scale. In particular, the work provides pairs of elastic and viscous fiber-scale moduli, which can reproduce the upper scale tendon mechanics. The computed range of values for the fiber-scale tendon viscosity attest to the substantial stress relaxation capabilities of tendons. More importantly, the reported mechanical parameters constitute a basis for the design of tendon-specific restoration materials, such as fiber-based, engineering scaffolds.
Collapse
|
28
|
Chambers NC, Herod TW, Veres SP. Ultrastructure of tendon rupture depends on strain rate and tendon type. J Orthop Res 2018; 36:2842-2850. [PMID: 29901228 DOI: 10.1002/jor.24067] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Accepted: 06/03/2018] [Indexed: 02/04/2023]
Abstract
Previous research has shown that both the mechanics and elongation mechanisms of tendon and ligament vary with strain rate during tensile loading. In this study, we sought to determine if the ultrastructural damage created during tendon rupture also varies with strain rate. A bovine forelimb model was used, allowing two anatomically proximate but physiologically distinct tendons to be studies: the positional common digital extensor tendon, and the energy storing superficial digital flexor tendon. Samples from the two tendon types were ruptured at rates of either 1%/s or 10%/s. Relative to unruptured control samples, changes to collagen fibril structure were assessed using scanning electron microscopy (SEM), and changes to collagen molecule packing were studied using differential scanning calorimetry (DSC). Rupture at 1%/s caused discrete plasticity damage that extended along the length of collagen fibrils in both the extensor and flexor tendons. Consistent with this, DSC showed molecular packing disruption relative to control samples. Both SEM and DSC showed that extensor tendon fibrils sustained more severe damage than the more highly crosslinked flexor tendon fibrils. Increasing strain rate during rupture decreased the level of longitudinal disruption experienced by the collagen fibrils of both tendon types. Disruption to D-banding was no longer seen in the extensor tendon fibrils, and discrete plasticity damage was completely eliminated in the flexor tendon fibrils, indicating a transition to localized point failure. Ultrastructural damage resulting from tendon rupture depends on both strain rate and tendon type. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2842-2850, 2018.
Collapse
Affiliation(s)
- Neil C Chambers
- Division of Engineering, Saint Mary's University, Halifax, Nova Scotia, Canada
| | - Tyler W Herod
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Samuel P Veres
- Division of Engineering, Saint Mary's University, Halifax, Nova Scotia, Canada
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| |
Collapse
|
29
|
Karathanasopoulos N, Arampatzis G, Ganghoffer JF. Unravelling the viscoelastic, buffer-like mechanical behavior of tendons: A numerical quantitative study at the fibril-fiber scale. J Mech Behav Biomed Mater 2018; 90:256-263. [PMID: 30388509 DOI: 10.1016/j.jmbbm.2018.10.019] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Revised: 08/04/2018] [Accepted: 10/09/2018] [Indexed: 11/17/2022]
Abstract
We investigate the capacity of tendons to bear substantial loads by exploiting their hierarchical structure and the viscous nature of their subunits. We model and analyze two successive tendon scales: the fibril and fiber subunits. We present a novel method for bridging intra-scale experimental observations by combining a homogenization analysis technique with a Bayesian inference method. This allows us to infer elastic and viscoelastic moduli at the embedded fibril scale that are mechanically compatible with the experimental data observed at the fiber scale. We identify the rather narrow range of moduli values at the fibrillar scale that can reproduce the mechanical behavior of the fiber, while we quantify the viscoelastic contribution of the embedding, non-collagenous matrix substance. The computed viscoelastic moduli suggest that a great part of the stress relaxation capacity of tendons needs to be attributed to the embedding matrix substance of its inner components, classifying it as a primal load relaxation constituent.
Collapse
Affiliation(s)
| | - Georgios Arampatzis
- Professorship for Computational Science, ETH Zurich, Clausiusstrasse 33, CH-8092 Zurich, Switzerland
| | | |
Collapse
|
30
|
Liu J, Das D, Yang F, Schwartz AG, Genin GM, Thomopoulos S, Chasiotis I. Energy dissipation in mammalian collagen fibrils: Cyclic strain-induced damping, toughening, and strengthening. Acta Biomater 2018; 80:217-227. [PMID: 30240954 PMCID: PMC6510236 DOI: 10.1016/j.actbio.2018.09.027] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2018] [Revised: 08/29/2018] [Accepted: 09/17/2018] [Indexed: 02/04/2023]
Abstract
As the fundamental structural protein in mammals, collagen transmits cyclic forces that are necessary for the mechanical function of tissues, such as bone and tendon. Although the tissue-level mechanical behavior of collagenous tissues is well understood, the response of collagen at the nanometer length scales to cyclical loading remains elusive. To address this major gap, we cyclically stretched individual reconstituted collagen fibrils, with average diameter of 145 ± 42 nm, to small and large strains in the partially hydrated conditions of 60% relative humidity. It is shown that cyclical loading results in large steady-state hysteresis that is reached immediately after the first loading cycle, followed thereafter by limited accumulation of inelastic strain and constant initial elastic modulus. Cyclic loading above 20% strain resulted in 70% increase in tensile strength, from 638 ± 98 MPa to 1091 ± 110 MPa, and 70% increase in toughness, while maintaining the ultimate tensile strain of collagen fibrils not subjected to cyclic loading. Throughout cyclic stretching, the fibrils maintained a steady-state hysteresis, yielding loss coefficients that are 5-10 times larger than those of known homogeneous materials in their modulus range, thus establishing damping of nanoscale collagen fibrils as a major component of damping in tissues. STATEMENT OF SIGNIFICANCE: It is shown that steady-state energy dissipation occurs in individual collagen fibrils that are the building blocks of hard and soft tissues. To date, it has been assumed that energy dissipation in tissues takes place mainly at the higher length scales of the tissue hierarchy due to interactions between collagen fibrils and fibers, and in limited extent inside collagen fibrils. It is shown that individual collagen fibrils need only a single loading cycle to assume a highly dissipative, steady-state, cyclic mechanical response. Mechanical cycling at large strains leads to 70% increase in mechanical strength and values exceeding those of engineering steels. The same cyclic loading conditions also lead to 70% increase in toughness and loss properties that are 5-10 times higher than those of engineering materials with comparable stiffness.
Collapse
Affiliation(s)
- Julia Liu
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Debashish Das
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Fan Yang
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Andrea G Schwartz
- Orthopaedic Surgery, Washington University, St. Louis, MO 60613, USA
| | - Guy M Genin
- Mechanical Engineering and Materials Science, Washington University, St. Louis, MO 63130, USA; NSF Science and Technology Center for Engineering Mechanobiology, St. Louis, MO 63130, USA
| | - Stavros Thomopoulos
- Orthopedic Surgery, Biomedical Engineering, Columbia University, New York, NY 10032, USA
| | - Ioannis Chasiotis
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| |
Collapse
|
31
|
Abstract
The hierarchical structure of tendon allows for attenuation of mechanical strain down decreasing length scales. While reorganization of collagen fibers accounts for microscale strain attenuation, cross-linking between collagen molecules contributes to deformation mechanisms at the fibrillar and molecular scales. Divalent and trivalent enzymatic cross-links form during the development of collagen fibrils through the enzymatic activity of lysyl oxidase (LOX). By establishing connections between telopeptidyl and triple-helical domains of adjacent molecules within collagen fibrils, these cross-links stiffen the fibrils by resisting intermolecular sliding. Ultimately, greater enzymatic cross-linking leads to less compliant and stronger tendon as a result of stiffer fibrils. In contrast, nonenzymatic cross-links such as glucosepane and pentosidine are not produced during development but slowly accumulate through glycation of collagen. Therefore, these cross-links are only expected to be present in significant quantities in advanced age, where there has been sufficient time for glycation to occur, and in diabetes, where the presence of more free sugar in the extracellular matrix increases the rate of glycation. Unlike enzymatic cross-links, current evidence suggests that nonenzymatic cross-links are at least partially isolated to the surface of collagen fibers. As a result, glycation has been proposed to primarily impact tendon mechanics by altering molecular interactions at the fiber interface, thereby diminishing sliding between fibers. Thus, increased nonenzymatic cross-linking decreases microscale strain attenuation and the viscous response of tendon. In conclusion, enzymatic and nonenzymatic collagen cross-links have demonstrable and distinct effects on the mechanical properties of tendon across different length scales.
Collapse
Affiliation(s)
- Jeremy D Eekhoff
- a Department of Biomedical Engineering , Washington University in St. Louis , St. Louis , USA
| | - Fei Fang
- b Department of Orthopedic Surgery , Columbia University , New York , USA
| | - Spencer P Lake
- a Department of Biomedical Engineering , Washington University in St. Louis , St. Louis , USA.,c Department of Mechanical Engineering and Materials Science , Washington University in St. Louis , St. Louis , USA.,d Department of Orthopaedic Surgery , Washington University in St. Louis , St. Louis , USA
| |
Collapse
|
32
|
Abstract
Introduction. Tendons are specialised, heterogeneous connective tissues, which represent a significant healthcare challenge after injury. Primary surgical repair is the gold standard modality of care; however, it is highly dependent on the extent of injuries. Tissue engineering represents an alternative solution for good tissue integration and regeneration. In this review, we look at the advanced biomaterial composites employed to improve cellular growth while providing appropriate mechanical properties for tendon and ligament repair. Methodology. Comprehensive literature searches focused on advanced composite biomaterials for tendon and ligament tissue engineering. Studies were categorised depending on the application. Results. In the literature, a range of natural and/or synthetic materials have been combined to produce composite scaffolds tendon and ligament tissue engineering. In vitro and in vivo assessment demonstrate promising cellular integration with sufficient mechanical strength. The biological properties were improved with the addition of growth factors within the composite materials. Most in vivo studies were completed in small-scale animal models. Conclusions. Advanced composite materials represent a promising solution to the challenges associated with tendon and ligament tissue engineering. Nevertheless, these approaches still demonstrate limitations, including the necessity of larger-scale animal models to ease future clinical translation and comprehensive assessment of tissue response after implantation.
Collapse
|
33
|
Cagle JC, Reinhall PG, Allyn KJ, McLean J, Hinrichs P, Hafner BJ, Sanders JE. A finite element model to assess transtibial prosthetic sockets with elastomeric liners. Med Biol Eng Comput 2018; 56:1227-1240. [PMID: 29235055 PMCID: PMC5999538 DOI: 10.1007/s11517-017-1758-z] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2017] [Accepted: 11/20/2017] [Indexed: 11/24/2022]
Abstract
People with transtibial amputation often experience skin breakdown due to the pressures and shear stresses that occur at the limb-socket interface. The purpose of this research was to create a transtibial finite element model (FEM) of a contemporary prosthesis that included complete socket geometry, two frictional interactions (limb-liner and liner-socket), and an elastomeric liner. Magnetic resonance imaging scans from three people with characteristic transtibial limb shapes (i.e., short-conical, long-conical, and cylindrical) were acquired and used to develop the models. Each model was evaluated with two loading profiles to identify locations of focused stresses during stance phase. The models identified five locations on the participants' residual limbs where peak stresses matched locations of mechanically induced skin issues they experienced in the 9 months prior to being scanned. The peak contact pressure across all simulations was 98 kPa and the maximum resultant shear stress was 50 kPa, showing reasonable agreement with interface stress measurements reported in the literature. Future research could take advantage of the developed FEM to assess the influence of changes in limb volume or liner material properties on interface stress distributions. Graphical abstract Residual limb finite element model. Left: model components. Right: interface pressures during stance phase.
Collapse
Affiliation(s)
- John C Cagle
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Per G Reinhall
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Kate J Allyn
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Jake McLean
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Paul Hinrichs
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Brian J Hafner
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Joan E Sanders
- Department of Bioengineering, University of Washington, Seattle, WA, USA.
| |
Collapse
|
34
|
Svensson RB, Smith ST, Moyer PJ, Magnusson SP. Effects of maturation and advanced glycation on tensile mechanics of collagen fibrils from rat tail and Achilles tendons. Acta Biomater 2018; 70:270-280. [PMID: 29447959 DOI: 10.1016/j.actbio.2018.02.005] [Citation(s) in RCA: 65] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Revised: 01/24/2018] [Accepted: 02/06/2018] [Indexed: 02/06/2023]
Abstract
Connective tissues are ubiquitous throughout the body and consequently affect the function of many organs. In load bearing connective tissues like tendon, the mechanical functionality is provided almost exclusively by collagen fibrils that in turn are stabilized by covalent cross-links. Functionally distinct tendons display different cross-link patterns, which also change with maturation, but these differences have not been studied in detail at the fibril level. In the present study, a custom built nanomechanical test platform was designed and fabricated to measure tensile mechanics of individual fibrils from rat tendons. The influence of animal maturity (4 vs. 16 week old rats) and functionally different tendons (tail vs. Achilles tendons) were examined. Additionally the effect of methylglyoxal (MG) treatment in vitro to form advanced glycation end products (AGEs) was investigated. Age and tissue type had no significant effect on fibril mechanics, but MG treatment increased strength and stiffness without inducing brittleness and gave rise to a distinct three-phase mechanical response corroborating that previously reported in human patellar tendon fibrils. That age and tissue had little mechanical effect, tentatively suggest that variations in enzymatic cross-links may play a minor role after initial tissue formation. STATEMENT OF SIGNIFICANCE Tendons are connective tissues that connect muscle to bone and carry some of the greatest mechanical loads in the body, which makes them common sites of injury. A tendon is essentially a biological rope formed by thin strands called fibrils made of the protein collagen. Tendon function relies on the strength of these fibrils, which in turn depends on naturally occurring cross-links between collagen molecules, but the mechanical influence of these cross-links have not been measured before. It is believed that beneficial cross-linking occurs with maturation while additional cross-linking with aging may lead to brittleness, but this study provides evidence that maturation has little effect on mechanical function and that age-related cross-linking does not result in brittle collagen fibrils.
Collapse
Affiliation(s)
- Rene B Svensson
- Institute of Sports Medicine Copenhagen, Department of Orthopedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
| | - Stuart T Smith
- Department of Mechanical Engineering and Engineering Science, University of North Carolina at Charlotte, Charlotte, NC, USA
| | - Patrick J Moyer
- Department of Physics and Optical Science, University of North Carolina at Charlotte, Charlotte, NC, USA
| | - S Peter Magnusson
- Institute of Sports Medicine Copenhagen, Department of Orthopedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark; Musculoskeletal Rehabilitation Research Unit, Bispebjerg Hospital, University Hospital of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
35
|
Quigley AS, Bancelin S, Deska-Gauthier D, Légaré F, Kreplak L, Veres SP. In tendons, differing physiological requirements lead to functionally distinct nanostructures. Sci Rep 2018. [PMID: 29535366 PMCID: PMC5849720 DOI: 10.1038/s41598-018-22741-8] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
The collagen-based tissues of animals are hierarchical structures: even tendon, the simplest collagenous tissue, has seven to eight levels of hierarchy. Tailoring tissue structure to match physiological function can occur at many different levels. We wanted to know if the control of tissue architecture to achieve function extends down to the nanoscale level of the individual, cable-like collagen fibrils. Using tendons from young adult bovine forelimbs, we performed stress-strain experiments on single collagen fibrils extracted from tendons with positional function, and tendons with energy storing function. Collagen fibrils from the two tendon types, which have known differences in intermolecular crosslinking, showed numerous differences in their responses to elongation. Unlike those from positional tendons, fibrils from energy storing tendons showed high strain stiffening and resistance to disruption in both molecular packing and conformation, helping to explain how these high stress tissues withstand millions of loading cycles with little reparative remodeling. Functional differences in load-bearing tissues are accompanied by important differences in nanoscale collagen fibril structure.
Collapse
Affiliation(s)
- Andrew S Quigley
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada
| | - Stéphane Bancelin
- Institut National de la Recherche Scientifique, Centre Énergie, Matériaux, Télécommunication, Varennes, Canada
| | | | - François Légaré
- Institut National de la Recherche Scientifique, Centre Énergie, Matériaux, Télécommunication, Varennes, Canada
| | - Laurent Kreplak
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada. .,School of Biomedical Engineering, Dalhousie University, Halifax, Canada.
| | - Samuel P Veres
- School of Biomedical Engineering, Dalhousie University, Halifax, Canada. .,Division of Engineering, Saint Mary's University, Halifax, Canada.
| |
Collapse
|
36
|
Slane LC, Bogaerts S, Thelen DG, Scheys L. Nonuniform Deformation of the Patellar Tendon During Passive Knee Flexion. J Appl Biomech 2018; 34:14-22. [PMID: 28787221 DOI: 10.1123/jab.2017-0067] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The purpose of this study was to evaluate localized patterns of patellar tendon deformation during passive knee flexion. Ultrasound radiofrequency data were collected from the patellar tendons of 20 healthy young adults during knee flexion over a range of motion of 50°-90° of flexion. A speckle tracking approach was used to compute proximal and distal tendon displacements and elongations. Nonuniform tissue displacements were visible in the proximal tendon (P < .001), with the deep tendon undergoing more distal displacement than the superficial tendon. In the distal tendon, more uniform tendon motion was observed. Spatial variations in percent elongation were also observed, but these varied along the length of the tendon (P < .002), with the proximal tendon remaining fairly isometric while the distal tendon underwent slight elongation. These results suggest that even during passive flexion the tendon undergoes complex patterns of deformation. Proximal tendon nonuniformity may arise from its complex anatomy where the deep tendon inserts onto the patella and the superficial tendon extends to the quadriceps tendon. Such heterogeneity is not captured in whole tendon average assessments, emphasizing the relevance of considering localized tendon mechanics, which may be key to understanding tendon behavior and precursors to injury and disease.
Collapse
|
37
|
Wu J, Yuan H, Li L, Fan K, Qian S, Li B. Viscoelastic shear lag model to predict the micromechanical behavior of tendon under dynamic tensile loading. J Theor Biol 2017; 437:202-213. [PMID: 29111420 DOI: 10.1016/j.jtbi.2017.10.018] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2017] [Revised: 10/13/2017] [Accepted: 10/16/2017] [Indexed: 12/26/2022]
Abstract
Owing to its viscoelastic nature, tendon exhibits stress rate-dependent breaking and stiffness function. A Kelvin-Voigt viscoelastic shear lag model is proposed to illustrate the micromechanical behavior of the tendon under dynamic tensile conditions. Theoretical closed-form expressions are derived to predict the deformation and stress transfer between fibrils and interfibrillar matrix while tendon is dynamically stretched. The results from the analytical solutions demonstrate that how the fibril overlap length and fibril volume fraction affect the stress transfer and mechanical properties of tendon. We find that the viscoelastic property of interfibrillar matrix mainly results in collagen fibril failure under fast loading rate or creep rupture of tendon. However, discontinuous fibril model and hierarchical structure of tendon ensure relative sliding under slow loading rate, helping dissipate energy and protecting fibril from damage, which may be a key reason why regularly staggering alignment microstructure is widely selected in nature. According to the growth, injury, healing and healed process of tendon observed by many researchers, the conclusions presented in this paper agrees well with the experimental findings. Additionally, the emphasis of this paper is on micromechanical behavior of tendon, whereas this analytical viscoelastic shear lag model can be equally applicable to other soft or hard tissues, owning the similar microstructure.
Collapse
Affiliation(s)
- Jiayu Wu
- MOE Key Laboratory of Disaster Forecast and Control in Engineering, Institute of Applied Mechanics, Jinan University, Guangzhou 510632, China; School of Engineering, University of Plymouth, Drake Circus, Plymouth PL4 8AA, UK
| | - Hong Yuan
- MOE Key Laboratory of Disaster Forecast and Control in Engineering, Institute of Applied Mechanics, Jinan University, Guangzhou 510632, China.
| | - Longyuan Li
- School of Engineering, University of Plymouth, Drake Circus, Plymouth PL4 8AA, UK
| | - Kunjie Fan
- School of Engineering, University of Plymouth, Drake Circus, Plymouth PL4 8AA, UK
| | - Shanguang Qian
- Architecture Engineering Faculty, Kunming Metallurgy College, Kumming 650033, China
| | - Bing Li
- Blackett Laboratory, Imperial College London, South Kensington Campus, SW7 2AZ, UK
| |
Collapse
|
38
|
Wu S, Wang Y, Streubel PN, Duan B. Living nanofiber yarn-based woven biotextiles for tendon tissue engineering using cell tri-culture and mechanical stimulation. Acta Biomater 2017; 62:102-115. [PMID: 28864251 PMCID: PMC5623069 DOI: 10.1016/j.actbio.2017.08.043] [Citation(s) in RCA: 115] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Revised: 08/16/2017] [Accepted: 08/28/2017] [Indexed: 12/28/2022]
Abstract
Non-woven nanofibrous scaffolds have been developed for tendon graft application by using electrospinning strategies. However, electrospun nanofibrous scaffolds face some obstacles and limitations, including suboptimal scaffold structure, weak tensile and suture-retention strengths, and compact structure for cell infiltration. In this work, a novel nanofibrous, woven biotextile, fabricated based on electrospun nanofiber yarns, was implemented as a tissue engineered tendon scaffold. Based on our modified electrospinning setup, polycaprolactone (PCL) nanofiber yarns were fabricated with reproducible quality, and were further processed into plain-weaving fabrics interlaced with polylactic acid (PLA) multifilaments. Nonwoven nanofibrous PCL meshes with random or aligned fiber structures were generated using typical electrospinning as comparative counterparts. The woven fabrics contained 3D aligned microstructures with significantly larger pore size and obviously enhanced tensile mechanical properties than their nonwoven counterparts. The biological results revealed that cell proliferation and infiltration, along with the expression of tendon-specific genes by human adipose derived mesenchymal stem cells (HADMSC) and human tenocytes (HT), were significantly enhanced on the woven fabrics compared with those on randomly-oriented or aligned nanofiber meshes. Co-cultures of HADMSC with HT or human umbilical vein endothelial cells (HUVEC) on woven fabrics significantly upregulated the functional expression of most tenogenic markers. HADMSC/HT/HUVEC tri-culture on woven fabrics showed the highest upregulation of most tendon-associated markers than all the other mono- and co-culture groups. Furthermore, we conditioned the tri-cultured constructs with dynamic conditioning and demonstrated that dynamic stretch promoted total collagen secretion and tenogenic differentiation. Our nanofiber yarn-based biotextiles have significant potential to be used as engineered scaffolds to synergize the multiple cell interaction and mechanical stimulation for promoting tendon regeneration. STATEMENT OF SIGNIFICANCE Tendon grafts are essential for the treatment of various tendon-related conditions due to the inherently poor healing capacity of native tendon tissues. In this study, we combined electrospun nanofiber yarns with textile manufacturing strategies to fabricate nanofibrous woven biotextiles with hierarchical features, aligned fibrous topography, and sufficient mechanical properties as tendon tissue engineered scaffolds. Comparing to traditional electrospun random or aligned meshes, our novel nanofibrous woven fabrics possess strong tensile and suture-retention strengths and larger pore size. We also demonstrated that the incorporation of tendon cells and vascular cells promoted the tenogenic differentiation of the engineered tendon constructs, especially under dynamic stretch. This study not only presents a novel tissue engineered tendon scaffold fabrication technique but also provides a useful strategy to promote tendon differentiation and regeneration.
Collapse
Affiliation(s)
- Shaohua Wu
- Mary & Dick Holland Regenerative Medicine Program, University of Nebraska Medical Center, Omaha, NE, USA; Division of Cardiology, Department of Internal Medicine, University of Nebraska Medical Center, Omaha, NE, USA
| | - Ying Wang
- Mary & Dick Holland Regenerative Medicine Program, University of Nebraska Medical Center, Omaha, NE, USA; Division of Cardiology, Department of Internal Medicine, University of Nebraska Medical Center, Omaha, NE, USA
| | - Philipp N Streubel
- Department of Orthopedic Surgery and Rehabilitation, University of Nebraska Medical Center, Omaha, NE, USA
| | - Bin Duan
- Mary & Dick Holland Regenerative Medicine Program, University of Nebraska Medical Center, Omaha, NE, USA; Division of Cardiology, Department of Internal Medicine, University of Nebraska Medical Center, Omaha, NE, USA; Department of Surgery, College of Medicine, University of Nebraska Medical Center, Omaha, NE, USA.
| |
Collapse
|
39
|
Mannarino P, Lima KMM, Fontenelle CRC, Matta TT, de Salles BF, Simão R, Oliveira LF. Analysis of the correlation between knee extension torque and patellar tendon elastic property. Clin Physiol Funct Imaging 2017; 38:378-383. [DOI: 10.1111/cpf.12424] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2016] [Accepted: 02/16/2017] [Indexed: 11/29/2022]
Affiliation(s)
- P. Mannarino
- Department of Orthopaedic Surgery; Clementino Fraga Filho University Hospital; UFRJ; Rio de Janeiro Brazil
- Biomedical Engineering Program; UFRJ; Rio de Janeiro Brazil
- Physical Education Post-Graduation Program; UFRJ; Rio de Janeiro Brazil
| | - K. M. M. Lima
- Biomedical Engineering Program; UFRJ; Rio de Janeiro Brazil
| | - C. R. C. Fontenelle
- Department of Orthopaedic Surgery; Clementino Fraga Filho University Hospital; UFRJ; Rio de Janeiro Brazil
| | - T. T. Matta
- Biomedical Engineering Program; UFRJ; Rio de Janeiro Brazil
| | - B. F. de Salles
- Physical Education Post-Graduation Program; UFRJ; Rio de Janeiro Brazil
| | - R. Simão
- Physical Education Post-Graduation Program; UFRJ; Rio de Janeiro Brazil
| | - L. F. Oliveira
- Biomedical Engineering Program; UFRJ; Rio de Janeiro Brazil
- Physical Education Post-Graduation Program; UFRJ; Rio de Janeiro Brazil
| |
Collapse
|
40
|
Fang F, Lake SP. Experimental evaluation of multiscale tendon mechanics. J Orthop Res 2017; 35:1353-1365. [PMID: 27878999 DOI: 10.1002/jor.23488] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Accepted: 11/16/2016] [Indexed: 02/04/2023]
Abstract
Tendon's primary function is a mechanical link between muscle and bone. The hierarchical structure of tendon and specific compositional constituents are believed to be critical for proper mechanical function. With increased appreciation for tendon importance and the development of various technological advances, this review paper summarizes recent experimental approaches that have been used to study multiscale tendon mechanics, includes an overview of studies that have evaluated the role of specific tissue constituents, and also proposes challenges/opportunities facing tendon study. Tendon has been demonstrated to have specific structural characteristics (e.g., multi-level hierarchy, crimp pattern, helix) and complex mechanical properties (e.g., non-linearity, anisotropy, viscoelasticity). Physical mechanisms including uncrimping, fiber sliding, and collagen reorganization have been shown to govern tendon mechanical responses under both static and dynamic loading. Several tendon constituents with relatively small quantities have been suggested to play a role in its mechanics, although some results are conflicting. Further research should be performed to understand the interplay and communication of tendon mechanical properties across levels of the hierarchical structure, and further show how each of these components contribute to tendon mechanics. The studies summarized and discussed in this review have helped elucidate important aspects of multiscale tendon mechanics, which is a prerequisite for analyzing stress/strain transfer between multiple scales and identifying key principles of mechanotransduction. This information could further facilitate interpreting the functional diversity of tendons from different species, different locations, and even different developmental stages, and then better understand and identify fundamental concepts related to tendon degeneration, disease, and healing. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1353-1365, 2017.
Collapse
Affiliation(s)
- Fei Fang
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130
| | - Spencer P Lake
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130.,Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130.,Department of Orthopaedic Surgery, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130
| |
Collapse
|
41
|
Advanced glycation end-products: Mechanics of aged collagen from molecule to tissue. Matrix Biol 2016; 59:95-108. [PMID: 27616134 DOI: 10.1016/j.matbio.2016.09.001] [Citation(s) in RCA: 166] [Impact Index Per Article: 20.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Revised: 08/29/2016] [Accepted: 09/01/2016] [Indexed: 01/03/2023]
Abstract
Concurrent with a progressive loss of regenerative capacity, connective tissue aging is characterized by a progressive accumulation of Advanced Glycation End-products (AGEs). Besides being part of the typical aging process, type II diabetics are particularly affected by AGE accumulation due to abnormally high levels of systemic glucose that increases the glycation rate of long-lived proteins such as collagen. Although AGEs are associated with a wide range of clinical disorders, the mechanisms by which AGEs contribute to connective tissue disease in aging and diabetes are still poorly understood. The present study harnesses advanced multiscale imaging techniques to characterize a widely employed in vitro model of ribose induced collagen aging and further benchmarks these data against experiments on native human tissues from donors of different age. These efforts yield unprecedented insight into the mechanical changes in collagen tissues across hierarchical scales from molecular, to fiber, to tissue-levels. We observed a linear increase in molecular spacing (from 1.45nm to 1.5nm) and a decrease in the D-period length (from 67.5nm to 67.1nm) in aged tissues, both using the ribose model of in vitro glycation and in native human probes. Multiscale mechanical analysis of in vitro glycated tendons strongly suggests that AGEs reduce tissue viscoelasticity by severely limiting fiber-fiber and fibril-fibril sliding. This study lays an important foundation for interpreting the functional and biological effects of AGEs in collagen connective tissues, by exploiting experimental models of AGEs crosslinking and benchmarking them for the first time against endogenous AGEs in native tissue.
Collapse
|
42
|
Quigley AS, Veres SP, Kreplak L. Bowstring Stretching and Quantitative Imaging of Single Collagen Fibrils via Atomic Force Microscopy. PLoS One 2016; 11:e0161951. [PMID: 27598334 PMCID: PMC5012574 DOI: 10.1371/journal.pone.0161951] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2016] [Accepted: 08/15/2016] [Indexed: 12/31/2022] Open
Abstract
Collagen is the primary structural protein in animals. Serving as nanoscale biological ropes, collagen fibrils are responsible for providing strength to a variety of connective tissues such as tendon, skin, and bone. Understanding structure-function relationships in collagenous tissues requires the ability to conduct a variety of mechanical experiments on single collagen fibrils. Though significant advances have been made, certain tests are not possible using the techniques currently available. In this report we present a new atomic force microscopy (AFM) based method for tensile manipulation and subsequent nanoscale structural assessment of single collagen fibrils. While the method documented here cannot currently capture force data during loading, it offers the great advantage of allowing structural assessment after subrupture loading. To demonstrate the utility of this technique, we describe the results of 23 tensile experiments in which collagen fibrils were loaded to varying levels of strain and subsequently imaged in both the hydrated and dehydrated states. We show that following a dehydration-rehydration cycle (necessary for sample preparation), fibrils experience an increase in height and decrease in radial modulus in response to one loading-unloading cycle to strain <5%. This change is not altered by a second cycle to strain >5%. In fibril segments that ruptured during their second loading cycle, we show that the fibril structure is affected away from the rupture site in the form of discrete permanent deformations. By comparing the severity of select damage sites in both hydrated and dehydrated conditions, we demonstrate that dehydration masks damage features, leading to an underestimate of the degree of structural disruption. Overall, the method shows promise as a powerful tool for the investigation of structure-function relationships in nanoscale fibrous materials.
Collapse
Affiliation(s)
- Andrew S. Quigley
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada
| | - Samuel P. Veres
- School of Biomedical Engineering, Dalhousie University, Halifax, Canada
- Division of Engineering, Saint Mary’s University, Halifax, Canada
| | - Laurent Kreplak
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada
- School of Biomedical Engineering, Dalhousie University, Halifax, Canada
- * E-mail:
| |
Collapse
|
43
|
Trumbull A, Subramanian G, Yildirim-Ayan E. Mechanoresponsive musculoskeletal tissue differentiation of adipose-derived stem cells. Biomed Eng Online 2016; 15:43. [PMID: 27103394 PMCID: PMC4840975 DOI: 10.1186/s12938-016-0150-9] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2015] [Accepted: 03/24/2016] [Indexed: 02/06/2023] Open
Abstract
Musculoskeletal tissues are constantly under mechanical strains within their microenvironment. Yet, little is understood about the effect of in vivo mechanical milieu strains on cell development and function. Thus, this review article outlines the in vivo mechanical environment of bone, muscle, cartilage, tendon, and ligaments, and tabulates the mechanical strain and stress in these tissues during physiological condition, vigorous, and moderate activities. This review article further discusses the principles of mechanical loading platforms to create physiologically relevant mechanical milieu in vitro for musculoskeletal tissue regeneration. A special emphasis is placed on adipose-derived stem cells (ADSCs) as an emerging valuable tool for regenerative musculoskeletal tissue engineering, as they are easily isolated, expanded, and able to differentiate into any musculoskeletal tissue. Finally, it highlights the current state-of-the art in ADSCs-guided musculoskeletal tissue regeneration under mechanical loading.
Collapse
Affiliation(s)
- Andrew Trumbull
- Department of Bioengineering, College of Engineering, University of Toledo, Toledo, OH, 43606, USA
| | - Gayathri Subramanian
- Department of Bioengineering, College of Engineering, University of Toledo, Toledo, OH, 43606, USA
| | - Eda Yildirim-Ayan
- Department of Bioengineering, College of Engineering, University of Toledo, Toledo, OH, 43606, USA. .,Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, OH, 43614, USA.
| |
Collapse
|
44
|
Manssor NAS, Radzi Z, Yahya NA, Mohamad Yusof L, Hariri F, Khairuddin NH, Abu Kasim NH, Czernuszka JT. Characteristics and Young's Modulus of Collagen Fibrils from Expanded Skin Using Anisotropic Controlled Rate Self-Inflating Tissue Expander. Skin Pharmacol Physiol 2016; 29:55-62. [PMID: 26836267 DOI: 10.1159/000431328] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2014] [Accepted: 05/11/2015] [Indexed: 11/19/2022]
Abstract
Mechanical properties of expanded skin tissue are different from normal skin, which is dependent mainly on the structural and functional integrity of dermal collagen fibrils. In the present study, mechanical properties and surface topography of both expanded and nonexpanded skin collagen fibrils were evaluated. Anisotropic controlled rate self-inflating tissue expanders were placed beneath the skin of sheep's forelimbs. The tissue expanders gradually increased in height and reached equilibrium in 2 weeks. They were left in situ for another 2 weeks before explantation. Expanded and normal skin samples were surgically harvested from the sheep (n = 5). Young's modulus and surface topography of collagen fibrils were measured using an atomic force microscope. A surface topographic scan showed organized hierarchical structural levels: collagen molecules, fibrils and fibers. No significant difference was detected for the D-banding pattern: 63.5 ± 2.6 nm (normal skin) and 63.7 ± 2.7 nm (expanded skin). Fibrils from expanded tissues consisted of loosely packed collagen fibrils and the width of the fibrils was significantly narrower compared to those from normal skin: 153.9 ± 25.3 and 106.7 ± 28.5 nm, respectively. Young's modulus of the collagen fibrils in the expanded and normal skin was not statistically significant: 46.5 ± 19.4 and 35.2 ± 27.0 MPa, respectively. In conclusion, the anisotropic controlled rate self-inflating tissue expander produced a loosely packed collagen network and the fibrils exhibited similar D-banding characteristics as the control group in a sheep model. However, the fibrils from the expanded skin were significantly narrower. The stiffness of the fibrils from the expanded skin was higher but it was not statistically different.
Collapse
|
45
|
Hammer N, Huster D, Boldt A, Hädrich C, Koch H, Möbius R, Schulze-Tanzil G, Scheidt HA. A preliminary technical study on sodium dodecyl sulfate-induced changes of the nano-structural and macro-mechanical properties in human iliotibial tract specimens. J Mech Behav Biomed Mater 2016; 61:164-173. [PMID: 26866452 DOI: 10.1016/j.jmbbm.2016.01.018] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2015] [Revised: 01/12/2016] [Accepted: 01/20/2016] [Indexed: 01/14/2023]
Abstract
INTRODUCTION Acellular scaffolds are frequently used for the surgical repair of ligaments and tendons. Even though data on the macro-mechanical properties related to the acellularization process exist, corresponding data on the nano-structural properties are still lacking. Such data would help identify target proteins of the formed extracellular matrix that are chemically altered by the acellularization. In this study we examined the altered structure by comparing molecular properties of collagens from native and acellular iliotibial tract samples to the macroscopic stress-strain behavior of tract samples. MATERIAL AND METHODS Matched pairs of five human iliotibial tract samples were obtained from five donors (mean age 28.2±4.7 years). One of each pair was acellularized using 1vol% sodium dodecyl sulfate (SDS) for 7 days. (13)C magic angle spinning nuclear magnetic resonance spectroscopy ((13)C CP MAS NMR) was utilized to compare the collagen overall secondary structure and internal dynamics of collagen-typical amino acid proteins. The resulting data was compared to age-matched stress-strain data of tract samples obtained in an uniaxial tensile setup and histologically. RESULTS Typical and nearly identical collagen (13)C CP MAS NMR spectra were found in the tract samples before and after acellularization with SDS. The characteristic collagen backbone remained intact in the native and acellular samples. Collagen molecular composition was largely unaltered in both conditions. Furthermore, a similar dynamic behavior was found for the amino acids Hyp γ, Pro α/Hyp α, Ala α, Gly α and Ala β. These minute alterations in the collagens' molecular properties related to acellularization with SDS were in line with the similarly minute changes in the macro-mechanical tensile behavior, such as the elastic modulus and ultimate stress. Histology showed intact type I collagens, minute amounts of elastins before and after acellularization and evidence for acellularization-induced reductions of proteoglycans. DISCUSSION Nano-structural properties of collagens are minutely affected by SDS treatment for acellularization, indicated by the molecular composition and dynamics. The lacking acellularization-related changes in the molecular structure properties of collagens in iliotibial tract samples are in line with the small alterations in their macro-mechanical tensile behavior. Though the given setup approaches soft tissue mechanics from both scaling extremes of mechanical testing, further structural analyzes are needed in a larger sample size to substantiate these findings.
Collapse
Affiliation(s)
- Niels Hammer
- Department of Anatomy, University of Otago, 270 Great King Street, Dunedin 9054, New Zealand.
| | - Daniel Huster
- Institute of Medical Physics and Biophysics, University of Leipzig, Faculty of Medicine, Leipzig, Germany
| | - Andreas Boldt
- Institute of Clinical Immunology, University of Leipzig, Faculty of Medicine, Leipzig, Germany; Translational Centre for Regenerative Medicine, University of Leipzig, Faculty of Medicine, Leipzig, Germany
| | - Carsten Hädrich
- Institute of Forensic Medicine, University of Leipzig, Faculty of Medicine, Leipzig, Germany
| | - Holger Koch
- Translational Centre for Regenerative Medicine, University of Leipzig, Faculty of Medicine, Leipzig, Germany
| | - Robert Möbius
- Institute of Anatomy, University of Leipzig, Faculty of Medicine, Leipzig, Germany
| | - Gundula Schulze-Tanzil
- Department of Anatomy, Nuremberg Hospital Medical School, Paracelsus Medical University, Nuremburg, Germany and Salzburg, Austria
| | - Holger A Scheidt
- Institute of Medical Physics and Biophysics, University of Leipzig, Faculty of Medicine, Leipzig, Germany
| |
Collapse
|
46
|
Methods of Assessing Human Tendon Metabolism and Tissue Properties in Response to Changes in Mechanical Loading. METABOLIC INFLUENCES ON RISK FOR TENDON DISORDERS 2016; 920:97-106. [DOI: 10.1007/978-3-319-33943-6_8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
47
|
Hsiao MY, Chen YC, Lin CY, Chen WS, Wang TG. Reduced Patellar Tendon Elasticity with Aging: In Vivo Assessment by Shear Wave Elastography. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:2899-2905. [PMID: 26304500 DOI: 10.1016/j.ultrasmedbio.2015.07.008] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Revised: 07/01/2015] [Accepted: 07/09/2015] [Indexed: 06/04/2023]
Abstract
How aging affects the elasticity of tendons has long been debated, partly because of the limited methods for in vivo evaluation, which differ vastly from those for in vitro animal studies. In this study, we tested the reliability of shear wave elastography (SWE) in the evaluation of patellar tendons and their change in elasticity with age. We recruited 62 healthy participants in three age groups: 20-30 years (group 1), 40-50 years (group 2) and 60-70 years (group 3). Shear wave velocity and elastic modulus were measured at the proximal, middle and distal areas of the patellar tendon. Reliability was excellent at the middle area and fair to good at both ends. Compared with the other groups, group 3 had significantly decreased elastic modulus and shear wave velocity values (p ≤ 0.001 vs. group 1 or 2), with significant increased side-to-side differences. SWE may be valuable in detecting aging tendons before visible abnormalities are observed on B-mode ultrasonography.
Collapse
Affiliation(s)
- Ming-Yen Hsiao
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital Bei-Hu Branch and National Taiwan University College of Medicine, Taipei City, Taiwan
| | - Yi-Ching Chen
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei City, Taiwan
| | - Che-Yu Lin
- Department of Orthopedic Surgery, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei City, Taiwan
| | - Wen-Shian Chen
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei City, Taiwan
| | - Tyng-Guey Wang
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei City, Taiwan.
| |
Collapse
|
48
|
Tronci G, Grant CA, Thomson NH, Russell SJ, Wood DJ. Multi-scale mechanical characterization of highly swollen photo-activated collagen hydrogels. J R Soc Interface 2015; 12:20141079. [PMID: 25411409 PMCID: PMC4277102 DOI: 10.1098/rsif.2014.1079] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
Biological hydrogels have been increasingly sought after as wound dressings or scaffolds for regenerative medicine, owing to their inherent biofunctionality in biological environments. Especially in moist wound healing, the ideal material should absorb large amounts of wound exudate while remaining mechanically competent in situ. Despite their large hydration, however, current biological hydrogels still leave much to be desired in terms of mechanical properties in physiological conditions. To address this challenge, a multi-scale approach is presented for the synthetic design of cyto-compatible collagen hydrogels with tunable mechanical properties (from the nano- up to the macro-scale), uniquely high swelling ratios and retained (more than 70%) triple helical features. Type I collagen was covalently functionalized with three different monomers, i.e. 4-vinylbenzyl chloride, glycidyl methacrylate and methacrylic anhydride, respectively. Backbone rigidity, hydrogen-bonding capability and degree of functionalization (F: 16 ± 12–91 ± 7 mol%) of introduced moieties governed the structure–property relationships in resulting collagen networks, so that the swelling ratio (SR: 707 ± 51–1996 ± 182 wt%), bulk compressive modulus (Ec: 30 ± 7–168 ± 40 kPa) and atomic force microscopy elastic modulus (EAFM: 16 ± 2–387 ± 66 kPa) were readily adjusted. Because of their remarkably high swelling and mechanical properties, these tunable collagen hydrogels may be further exploited for the design of advanced dressings for chronic wound care.
Collapse
Affiliation(s)
- Giuseppe Tronci
- Nonwovens Research Group, School of Design, University of Leeds, Leeds LS2 9JT, UK Biomaterials and Tissue Engineering Research Group, School of Dentistry, University of Leeds, Leeds LS2 9LU, UK
| | - Colin A Grant
- Advanced Materials Engineering RKT Centre, School of Engineering, University of Bradford, Bradford BD7 1DP, UK
| | - Neil H Thomson
- Molecular and Nanoscale Physics, School of Physics and Astronomy, University of Leeds, Leeds LS2 9JT, UK Biomineralisation Research Group, School of Dentistry, University of Leeds, Leeds LS2 9LU, UK
| | - Stephen J Russell
- Nonwovens Research Group, School of Design, University of Leeds, Leeds LS2 9JT, UK
| | - David J Wood
- Biomaterials and Tissue Engineering Research Group, School of Dentistry, University of Leeds, Leeds LS2 9LU, UK
| |
Collapse
|
49
|
Shah RR, Nerurkar NL, Wang C, Galloway JL. Tensile properties of craniofacial tendons in the mature and aged zebrafish. J Orthop Res 2015; 33:867-73. [PMID: 25665155 PMCID: PMC4417054 DOI: 10.1002/jor.22847] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2014] [Accepted: 01/27/2015] [Indexed: 02/04/2023]
Abstract
The zebrafish Danio rerio is a powerful model for the study of development, regenerative biology, and human disease. However, the analysis of load-bearing tissues such as tendons and ligaments has been limited in this system. This is largely due to technical limitations that preclude accurate measurement of their mechanical properties. Here, we present a custom tensile testing system that applies nano-Newton scale forces to zebrafish tendons as small as 1 mm in length. Tendon properties were remarkably similar to mammalian tendons, including stress-strain nonlinearity and a linear modulus (515 ± 152 MPa) that aligned closely with mammalian data. Additionally, a simple exponential constitutive law used to describe tendon mechanics was successfully fit to zebrafish tendons; the associated material constants agreed with literature values for mammalian tendons. Finally, mature and aged zebrafish comparisons revealed a significant decline in mechanical function with age. Based on the exponential constitutive model, age-related changes were primarily caused by a reduction in nonlinearity (e.g., changes in collagen crimp or fiber recruitment). These findings demonstrate the utility of zebrafish as a model to study tendon biomechanics in health and disease. Moreover, these findings suggest that tendon mechanical behavior is highly conserved across vertebrates.
Collapse
Affiliation(s)
- Rishita R. Shah
- Center for Regenerative Medicine, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Harvard Stem Cell Institute
| | - Nandan L. Nerurkar
- Department of Genetics, Harvard Medical School, NRB 360, 77 Avenue Louis Pasteur, Boston, MA 02129, P (617) 432-6533, F (617) 432-7595,co-corresponding authors
| | - Calvin Wang
- Center for Regenerative Medicine, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Harvard Stem Cell Institute
| | - Jenna L. Galloway
- Center for Regenerative Medicine, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Harvard Stem Cell Institute, 185 Cambridge Street, Boston, MA 02114, P (617) 643-4958, F (617) 724-2662,
| |
Collapse
|
50
|
Böl M, Ehret AE, Leichsenring K, Ernst M. Tissue-scale anisotropy and compressibility of tendon in semi-confined compression tests. J Biomech 2015; 48:1092-8. [DOI: 10.1016/j.jbiomech.2015.01.024] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2014] [Revised: 01/16/2015] [Accepted: 01/20/2015] [Indexed: 01/22/2023]
|