1
|
Brummer J, Glasbrenner C, Hechenbichler Figueroa S, Koehler K, Höchsmann C. Continuous glucose monitoring for automatic real-time assessment of eating events and nutrition: a scoping review. Front Nutr 2024; 10:1308348. [PMID: 38264192 PMCID: PMC10804456 DOI: 10.3389/fnut.2023.1308348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 12/13/2023] [Indexed: 01/25/2024] Open
Abstract
Background Accurate dietary assessment remains a challenge, particularly in free-living settings. Continuous glucose monitoring (CGM) shows promise in optimizing the assessment and monitoring of ingestive activity (IA, i.e., consumption of calorie-containing foods/beverages), and it might enable administering dietary Just-In-Time Adaptive Interventions (JITAIs). Objective In a scoping review, we aimed to answer the following questions: (1) Which CGM approaches to automatically detect IA in (near-)real-time have been investigated? (2) How accurate are these approaches? (3) Can they be used in the context of JITAIs? Methods We systematically searched four databases until October 2023 and included publications in English or German that used CGM-based approaches for human (all ages) IA detection. Eligible publications included a ground-truth method as a comparator. We synthesized the evidence qualitatively and critically appraised publication quality. Results Of 1,561 potentially relevant publications identified, 19 publications (17 studies, total N = 311; for 2 studies, 2 publications each were relevant) were included. Most publications included individuals with diabetes, often using meal announcements and/or insulin boluses accompanying meals. Inpatient and free-living settings were used. CGM-only approaches and CGM combined with additional inputs were deployed. A broad range of algorithms was tested. Performance varied among the reviewed methods, ranging from unsatisfactory to excellent (e.g., 21% vs. 100% sensitivity). Detection times ranged from 9.0 to 45.0 min. Conclusion Several CGM-based approaches are promising for automatically detecting IA. However, response times need to be faster to enable JITAIs aimed at impacting acute IA. Methodological issues and overall heterogeneity among articles prevent recommending one single approach; specific cases will dictate the most suitable approach.
Collapse
|
2
|
Bergford S, Riddell MC, Jacobs PG, Li Z, Gal RL, Clements MA, Doyle FJ, Martin CK, Patton SR, Castle JR, Gillingham MB, Beck RW, Rickels MR, Calhoun P. The Type 1 Diabetes and EXercise Initiative: Predicting Hypoglycemia Risk During Exercise for Participants with Type 1 Diabetes Using Repeated Measures Random Forest. Diabetes Technol Ther 2023; 25:602-611. [PMID: 37294539 PMCID: PMC10623079 DOI: 10.1089/dia.2023.0140] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Objective: Exercise is known to increase the risk for hypoglycemia in type 1 diabetes (T1D) but predicting when it may occur remains a major challenge. The objective of this study was to develop a hypoglycemia prediction model based on a large real-world study of exercise in T1D. Research Design and Methods: Structured study-specified exercise (aerobic, interval, and resistance training videos) and free-living exercise sessions from the T1D Exercise Initiative study were used to build a model for predicting hypoglycemia, a continuous glucose monitoring value <70 mg/dL, during exercise. Repeated measures random forest (RMRF) and repeated measures logistic regression (RMLR) models were constructed to predict hypoglycemia using predictors at the start of exercise and baseline characteristics. Models were evaluated with area under the receiver operating characteristic curve (AUC) and balanced accuracy. Results: RMRF and RMLR had similar AUC (0.833 vs. 0.825, respectively) and both models had a balanced accuracy of 77%. The probability of hypoglycemia was higher for exercise sessions with lower pre-exercise glucose levels, negative pre-exercise glucose rates of change, greater percent time <70 mg/dL in the 24 h before exercise, and greater pre-exercise bolus insulin-on-board (IOB). Free-living aerobic exercises, walking/hiking, and physical labor had the highest probability of hypoglycemia, while structured exercises had the lowest probability of hypoglycemia. Conclusions: RMRF and RMLR accurately predict hypoglycemia during exercise and identify factors that increase the risk of hypoglycemia. Lower glucose, decreasing levels of glucose before exercise, and greater pre-exercise IOB largely predict hypoglycemia risk in adults with T1D.
Collapse
Affiliation(s)
| | | | - Peter G. Jacobs
- Artificial Intelligence for Medical Systems Lab, Department of Biomedical Engineering, Oregon Health and Science University, Portland, Oregon, USA
| | - Zoey Li
- JAEB Center for Health Research, Tampa, Florida, USA
| | - Robin L. Gal
- JAEB Center for Health Research, Tampa, Florida, USA
| | | | - Francis J. Doyle
- Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts, USA
| | - Corby K. Martin
- Pennington Biomedical Research Center, Louisiana State University, Baton Rouge, Louisiana, USA
| | | | - Jessica R. Castle
- Harold Schnitzer Diabetes Health Center, Oregon Health and Science University, Portland, Oregon, USA
| | - Melanie B. Gillingham
- Department of Molecular and Medical Genetics, Oregon Health and Science University, Portland, Oregon, USA
| | - Roy W. Beck
- JAEB Center for Health Research, Tampa, Florida, USA
| | - Michael R. Rickels
- Institute for Diabetes, Obesity and Metabolism, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania, USA
| | - Peter Calhoun
- JAEB Center for Health Research, Tampa, Florida, USA
| |
Collapse
|
3
|
Abstract
First envisioned by early diabetes clinicians, a person-centred approach to care was an aspirational goal that aimed to match insulin therapy to each individual's unique requirements. In the 100 years since the discovery of insulin, this goal has evolved to include personalised approaches to type 1 diabetes diagnosis, treatment, prevention and prediction. These advances have been facilitated by the recognition of type 1 diabetes as an autoimmune disease and by advances in our understanding of diabetes pathophysiology, genetics and natural history, which have occurred in parallel with advancements in insulin delivery, glucose monitoring and tools for self-management. In this review, we discuss how these personalised approaches have improved diabetes care and how improved understanding of pathogenesis and human biology might inform precision medicine in the future.
Collapse
Affiliation(s)
- Alice L J Carr
- Institute of Biomedical and Clinical Science, University of Exeter Medical School, Exeter, UK.
| | - Carmella Evans-Molina
- Department of Pediatrics, Indiana University School of Medicine, Indianapolis, IN, USA
- Department of Medicine, Indiana University School of Medicine, Indianapolis, IN, USA
- Department of Anatomy, Cell Biology, and Physiology, Indiana University School of Medicine, Indianapolis, IN, USA
- Department of Biochemistry and Molecular Biology, Indiana University School of Medicine, Indianapolis, IN, USA
- Center for Diabetes and Metabolic Diseases, Indiana University School of Medicine, Indianapolis, IN, USA
- Herman B. Wells Center for Pediatric Research, Indiana University School of Medicine, Indianapolis, IN, USA
- Richard L. Roudebush VA Medical Center, Indianapolis, IN, USA
| | - Richard A Oram
- Institute of Biomedical and Clinical Science, University of Exeter Medical School, Exeter, UK.
| |
Collapse
|
4
|
Hettiarachchi C, Daskalaki E, Desborough J, Nolan CJ, O'Neal D, Suominen H. Integrating Multiple Inputs Into an Artificial Pancreas System: Narrative Literature Review. JMIR Diabetes 2022; 7:e28861. [PMID: 35200143 PMCID: PMC8914747 DOI: 10.2196/28861] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 06/07/2021] [Accepted: 01/01/2022] [Indexed: 12/02/2022] Open
Abstract
BACKGROUND Type 1 diabetes (T1D) is a chronic autoimmune disease in which a deficiency in insulin production impairs the glucose homeostasis of the body. Continuous subcutaneous infusion of insulin is a commonly used treatment method. Artificial pancreas systems (APS) use continuous glucose level monitoring and continuous subcutaneous infusion of insulin in a closed-loop mode incorporating a controller (or control algorithm). However, the operation of APS is challenging because of complexities arising during meals, exercise, stress, sleep, illnesses, glucose sensing and insulin action delays, and the cognitive burden. To overcome these challenges, options to augment APS through integration of additional inputs, creating multi-input APS (MAPS), are being investigated. OBJECTIVE The aim of this survey is to identify and analyze input data, control architectures, and validation methods of MAPS to better understand the complexities and current state of such systems. This is expected to be valuable in developing improved systems to enhance the quality of life of people with T1D. METHODS A literature survey was conducted using the Scopus, PubMed, and IEEE Xplore databases for the period January 1, 2005, to February 10, 2020. On the basis of the search criteria, 1092 articles were initially shortlisted, of which 11 (1.01%) were selected for an in-depth narrative analysis. In addition, 6 clinical studies associated with the selected studies were also analyzed. RESULTS Signals such as heart rate, accelerometer readings, energy expenditure, and galvanic skin response captured by wearable devices were the most frequently used additional inputs. The use of invasive (blood or other body fluid analytes) inputs such as lactate and adrenaline were also simulated. These inputs were incorporated to switch the mode of the controller through activity detection, directly incorporated for decision-making and for the development of intermediate modules for the controller. The validation of the MAPS was carried out through the use of simulators based on different physiological models and clinical trials. CONCLUSIONS The integration of additional physiological signals with continuous glucose level monitoring has the potential to optimize glucose control in people with T1D through addressing the identified limitations of APS. Most of the identified additional inputs are related to wearable devices. The rapid growth in wearable technologies can be seen as a key motivator regarding MAPS. However, it is important to further evaluate the practical complexities and psychosocial aspects associated with such systems in real life.
Collapse
Affiliation(s)
- Chirath Hettiarachchi
- School of Computing, College of Engineering and Computer Science, The Australian National University, Canberra, Australia
| | - Elena Daskalaki
- School of Computing, College of Engineering and Computer Science, The Australian National University, Canberra, Australia
| | - Jane Desborough
- Department of Health Services Research and Policy, Research School of Population Health, College of Health and Medicine, The Australian National University, Canberra, Australia
| | - Christopher J Nolan
- Australian National University Medical School, College of Health and Medicine, The Australian National University, Canberra, Australia
- John Curtin School of Medical Research, College of Health and Medicine, The Australian National University, Canberra, Australia
| | - David O'Neal
- Department of Medicine, University of Melbourne, Melbourne, Australia
- Department of Endocrinology and Diabetes, St Vincent's Hospital Melbourne, Melbourne, Australia
| | - Hanna Suominen
- School of Computing, College of Engineering and Computer Science, The Australian National University, Canberra, Australia
- Data61, Commonwealth Industrial and Scientific Research Organisation, Canberra, Australia
- Department of Computing, University of Turku, Turku, Finland
| |
Collapse
|
5
|
Intelligent automated drug administration and therapy: future of healthcare. Drug Deliv Transl Res 2021; 11:1878-1902. [PMID: 33447941 DOI: 10.1007/s13346-020-00876-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/09/2020] [Indexed: 12/13/2022]
Abstract
In the twenty-first century, the collaboration of control engineering and the healthcare sector has matured to some extent; however, the future will have promising opportunities, vast applications, and some challenges. Due to advancements in processing speed, the closed-loop administration of drugs has gained popularity for critically ill patients in intensive care units and routine life such as personalized drug delivery or implantable therapeutic devices. For developing a closed-loop drug delivery system, the control system works with a group of technologies like sensors, micromachining, wireless technologies, and pharmaceuticals. Recently, the integration of artificial intelligence techniques such as fuzzy logic, neural network, and reinforcement learning with the closed-loop drug delivery systems has brought their applications closer to fully intelligent automatic healthcare systems. This review's main objectives are to discuss the current developments, possibilities, and future visions in closed-loop drug delivery systems, for providing treatment to patients suffering from chronic diseases. It summarizes the present insight of closed-loop drug delivery/therapy for diabetes, gastrointestinal tract disease, cancer, anesthesia administration, cardiac ailments, and neurological disorders, from a perspective to show the research in the area of control theory.
Collapse
|
6
|
Sevil M, Rashid M, Maloney Z, Hajizadeh I, Samadi S, Askari MR, Hobbs N, Brandt R, Park M, Quinn L, Cinar A. Determining Physical Activity Characteristics from Wristband Data for Use in Automated Insulin Delivery Systems. IEEE SENSORS JOURNAL 2020; 20:12859-12870. [PMID: 33100923 PMCID: PMC7584145 DOI: 10.1109/jsen.2020.3000772] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Algorithms that can determine the type of physical activity (PA) and quantify the intensity can allow precision medicine approaches, such as automated insulin delivery systems that modulate insulin administration in response to PA. In this work, data from a multi-sensor wristband is used to design classifiers to distinguish among five different physical states (PS) (resting, activities of daily living, running, biking, and resistance training), and to develop models to estimate the energy expenditure (EE) of the PA for diabetes therapy. The data collected are filtered, features are extracted from the reconciled signals, and the extracted features are used by machine learning algorithms, including deep-learning techniques, to obtain accurate PS classification and EE estimation. The various machine learning techniques have different success rates ranging from 75.7% to 94.8% in classifying the five different PS. The deep neural network model with long short-term memory has 94.8% classification accuracy. We achieved 0.5 MET (Metabolic Equivalent of Task) root-mean-square error for EE estimation accuracy, relative to indirect calorimetry with randomly selected testing data (10% of collected data). We also demonstrate a 5% improvement in PS classification accuracy and a 0.34 MET decrease in the mean absolute error when using multi-sensor approach relative to using only accelerometer data.
Collapse
Affiliation(s)
- Mert Sevil
- Mert Sevil, Rachel Brandt, Nicole Hobbs and Zacharie Maloney are with the Department of Biomedical Engineering (BME); Mudassir Rashid, Mohammad Reza Askari, Iman Hajizadeh and Sedigeh Samadi are with the Department of Chemical and Biological Engineering (ChBE); Ali Cinar is with the Departments of ChBE and BME, Illinois Institute of Technology, Chicago, IL 60616; Minsun Park and Laurie Quinn are with the College of Nursing, University of Illinois at Chicago, IL, 60616
| | - Mudassir Rashid
- Mert Sevil, Rachel Brandt, Nicole Hobbs and Zacharie Maloney are with the Department of Biomedical Engineering (BME); Mudassir Rashid, Mohammad Reza Askari, Iman Hajizadeh and Sedigeh Samadi are with the Department of Chemical and Biological Engineering (ChBE); Ali Cinar is with the Departments of ChBE and BME, Illinois Institute of Technology, Chicago, IL 60616; Minsun Park and Laurie Quinn are with the College of Nursing, University of Illinois at Chicago, IL, 60616
| | - Zacharie Maloney
- Mert Sevil, Rachel Brandt, Nicole Hobbs and Zacharie Maloney are with the Department of Biomedical Engineering (BME); Mudassir Rashid, Mohammad Reza Askari, Iman Hajizadeh and Sedigeh Samadi are with the Department of Chemical and Biological Engineering (ChBE); Ali Cinar is with the Departments of ChBE and BME, Illinois Institute of Technology, Chicago, IL 60616; Minsun Park and Laurie Quinn are with the College of Nursing, University of Illinois at Chicago, IL, 60616
| | - Iman Hajizadeh
- Mert Sevil, Rachel Brandt, Nicole Hobbs and Zacharie Maloney are with the Department of Biomedical Engineering (BME); Mudassir Rashid, Mohammad Reza Askari, Iman Hajizadeh and Sedigeh Samadi are with the Department of Chemical and Biological Engineering (ChBE); Ali Cinar is with the Departments of ChBE and BME, Illinois Institute of Technology, Chicago, IL 60616; Minsun Park and Laurie Quinn are with the College of Nursing, University of Illinois at Chicago, IL, 60616
| | - Sediqeh Samadi
- Mert Sevil, Rachel Brandt, Nicole Hobbs and Zacharie Maloney are with the Department of Biomedical Engineering (BME); Mudassir Rashid, Mohammad Reza Askari, Iman Hajizadeh and Sedigeh Samadi are with the Department of Chemical and Biological Engineering (ChBE); Ali Cinar is with the Departments of ChBE and BME, Illinois Institute of Technology, Chicago, IL 60616; Minsun Park and Laurie Quinn are with the College of Nursing, University of Illinois at Chicago, IL, 60616
| | - Mohammad Reza Askari
- Mert Sevil, Rachel Brandt, Nicole Hobbs and Zacharie Maloney are with the Department of Biomedical Engineering (BME); Mudassir Rashid, Mohammad Reza Askari, Iman Hajizadeh and Sedigeh Samadi are with the Department of Chemical and Biological Engineering (ChBE); Ali Cinar is with the Departments of ChBE and BME, Illinois Institute of Technology, Chicago, IL 60616; Minsun Park and Laurie Quinn are with the College of Nursing, University of Illinois at Chicago, IL, 60616
| | - Nicole Hobbs
- Mert Sevil, Rachel Brandt, Nicole Hobbs and Zacharie Maloney are with the Department of Biomedical Engineering (BME); Mudassir Rashid, Mohammad Reza Askari, Iman Hajizadeh and Sedigeh Samadi are with the Department of Chemical and Biological Engineering (ChBE); Ali Cinar is with the Departments of ChBE and BME, Illinois Institute of Technology, Chicago, IL 60616; Minsun Park and Laurie Quinn are with the College of Nursing, University of Illinois at Chicago, IL, 60616
| | - Rachel Brandt
- Mert Sevil, Rachel Brandt, Nicole Hobbs and Zacharie Maloney are with the Department of Biomedical Engineering (BME); Mudassir Rashid, Mohammad Reza Askari, Iman Hajizadeh and Sedigeh Samadi are with the Department of Chemical and Biological Engineering (ChBE); Ali Cinar is with the Departments of ChBE and BME, Illinois Institute of Technology, Chicago, IL 60616; Minsun Park and Laurie Quinn are with the College of Nursing, University of Illinois at Chicago, IL, 60616
| | - Minsun Park
- Mert Sevil, Rachel Brandt, Nicole Hobbs and Zacharie Maloney are with the Department of Biomedical Engineering (BME); Mudassir Rashid, Mohammad Reza Askari, Iman Hajizadeh and Sedigeh Samadi are with the Department of Chemical and Biological Engineering (ChBE); Ali Cinar is with the Departments of ChBE and BME, Illinois Institute of Technology, Chicago, IL 60616; Minsun Park and Laurie Quinn are with the College of Nursing, University of Illinois at Chicago, IL, 60616
| | - Laurie Quinn
- Mert Sevil, Rachel Brandt, Nicole Hobbs and Zacharie Maloney are with the Department of Biomedical Engineering (BME); Mudassir Rashid, Mohammad Reza Askari, Iman Hajizadeh and Sedigeh Samadi are with the Department of Chemical and Biological Engineering (ChBE); Ali Cinar is with the Departments of ChBE and BME, Illinois Institute of Technology, Chicago, IL 60616; Minsun Park and Laurie Quinn are with the College of Nursing, University of Illinois at Chicago, IL, 60616
| | - Ali Cinar
- Mert Sevil, Rachel Brandt, Nicole Hobbs and Zacharie Maloney are with the Department of Biomedical Engineering (BME); Mudassir Rashid, Mohammad Reza Askari, Iman Hajizadeh and Sedigeh Samadi are with the Department of Chemical and Biological Engineering (ChBE); Ali Cinar is with the Departments of ChBE and BME, Illinois Institute of Technology, Chicago, IL 60616; Minsun Park and Laurie Quinn are with the College of Nursing, University of Illinois at Chicago, IL, 60616
| |
Collapse
|
7
|
Xie J, Wang Q. A Data-Driven Personalized Model of Glucose Dynamics Taking Account of the Effects of Physical Activity for Type 1 Diabetes: An In Silico Study. J Biomech Eng 2020; 141:2703963. [PMID: 30458503 DOI: 10.1115/1.4041522] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Indexed: 12/17/2022]
Abstract
This paper aims to develop a data-driven model for glucose dynamics taking into account the effects of physical activity (PA) through a numerical study. It intends to investigate PA's immediate effect on insulin-independent glucose variation and PA's prolonged effect on insulin sensitivity. We proposed a nonlinear model with PA (NLPA), consisting of a linear regression of PA and a bilinear regression of insulin and PA. The model was identified and evaluated using data generated from a physiological PA-glucose model by Dalla Man et al. integrated with the uva/padova Simulator. Three metrics were computed to compare blood glucose (BG) predictions by NLPA, a linear model with PA (LPA), and a linear model with no PA (LOPA). For PA's immediate effect on glucose, NLPA and LPA showed 45-160% higher mean goodness of fit (FIT) than LOPA under 30 min-ahead glucose prediction (P < 0.05). For the prolonged PA effect on glucose, NLPA showed 87% higher FIT than LPA (P < 0.05) for simulations using no previous measurements. NLPA had 25-37% and 31-54% higher sensitivity in predicting postexercise hypoglycemia than LPA and LOPA, respectively. This study demonstrated the following qualitative trends: (1) for moderate-intensity exercise, accuracy of BG prediction was improved by explicitly accounting for PA's effect; and (2) accounting for PA's prolonged effect on insulin sensitivity can increase the chance of early prediction of postexercise hypoglycemia. Such observations will need to be further evaluated through human subjects in the future.
Collapse
Affiliation(s)
- Jinyu Xie
- Mechanical and Nuclear Engineering, 315 Leonhard Building, Penn State University, University Park, PA 16802 e-mail:
| | - Qian Wang
- Mem. ASME Professor Mechanical Engineering, 325 Leonhard Building, Penn State University, University Park, PA 16802 e-mail:
| |
Collapse
|
8
|
Abstract
The advent of insulin pump therapy marked an important milestone in diabetes treatment in the past few decades and has become the tipping point for the development of automated insulin delivery systems (AID). Standalone insulin pump systems have evolved over the course of years and have been replaced by modern high-technology insulin pumps with continuous glucose monitor interface allowing real-time insulin dose adjustment to optimize treatment. This review summarizes evidence from AID studies conducted in children with type 1 diabetes and discusses the outlook for future generation AID systems from a pediatric treatment perspective.
Collapse
Affiliation(s)
- Eda Cengiz
- Yale School of Medicine, 333 Cedar Street, PO Box 208064, New Haven, CT 06520, USA; Bahçeşehir Üniversitesi, Istanbul, Turkey.
| |
Collapse
|
9
|
Lal RA, Ekhlaspour L, Hood K, Buckingham B. Realizing a Closed-Loop (Artificial Pancreas) System for the Treatment of Type 1 Diabetes. Endocr Rev 2019; 40:1521-1546. [PMID: 31276160 PMCID: PMC6821212 DOI: 10.1210/er.2018-00174] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Accepted: 02/28/2019] [Indexed: 01/20/2023]
Abstract
Recent, rapid changes in the treatment of type 1 diabetes have allowed for commercialization of an "artificial pancreas" that is better described as a closed-loop controller of insulin delivery. This review presents the current state of closed-loop control systems and expected future developments with a discussion of the human factor issues in allowing automation of glucose control. The goal of these systems is to minimize or prevent both short-term and long-term complications from diabetes and to decrease the daily burden of managing diabetes. The closed-loop systems are generally very effective and safe at night, have allowed for improved sleep, and have decreased the burden of diabetes management overnight. However, there are still significant barriers to achieving excellent daytime glucose control while simultaneously decreasing the burden of daytime diabetes management. These systems use a subcutaneous continuous glucose sensor, an algorithm that accounts for the current glucose and rate of change of the glucose, and the amount of insulin that has already been delivered to safely deliver insulin to control hyperglycemia, while minimizing the risk of hypoglycemia. The future challenge will be to allow for full closed-loop control with minimal burden on the patient during the day, alleviating meal announcements, carbohydrate counting, alerts, and maintenance. The human factors involved with interfacing with a closed-loop system and allowing the system to take control of diabetes management are significant. It is important to find a balance between enthusiasm and realistic expectations and experiences with the closed-loop system.
Collapse
Affiliation(s)
- Rayhan A Lal
- Division of Endocrinology, Department of Pediatrics, Stanford University School of Medicine, Stanford, California.,Division of Endocrinology, Department of Medicine, Stanford University School of Medicine, Stanford, California
| | - Laya Ekhlaspour
- Division of Endocrinology, Department of Pediatrics, Stanford University School of Medicine, Stanford, California
| | - Korey Hood
- Division of Endocrinology, Department of Pediatrics, Stanford University School of Medicine, Stanford, California.,Department of Psychiatry, Stanford University School of Medicine, Stanford, California
| | - Bruce Buckingham
- Division of Endocrinology, Department of Pediatrics, Stanford University School of Medicine, Stanford, California
| |
Collapse
|
10
|
Reddy R, Resalat N, Wilson LM, Castle JR, El Youssef J, Jacobs PG. Prediction of Hypoglycemia During Aerobic Exercise in Adults With Type 1 Diabetes. J Diabetes Sci Technol 2019; 13:919-927. [PMID: 30650997 PMCID: PMC6955453 DOI: 10.1177/1932296818823792] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
BACKGROUND Fear of exercise related hypoglycemia is a major reason why people with type 1 diabetes (T1D) do not exercise. There is no validated prediction algorithm that can predict hypoglycemia at the start of aerobic exercise. METHODS We have developed and evaluated two separate algorithms to predict hypoglycemia at the start of exercise. Model 1 is a decision tree and model 2 is a random forest model. Both models were trained using a meta-data set based on 154 observations of in-clinic aerobic exercise in 43 adults with T1D from 3 different studies that included participants using sensor augmented pump therapy, automated insulin delivery therapy, and automated insulin and glucagon therapy. Both models were validated using an entirely new validation data set with 90 exercise observations collected from 12 new adults with T1D. RESULTS Model 1 identified two critical features predictive of hypoglycemia during exercise: heart rate and glucose at the start of exercise. If heart rate was greater than 121 bpm during the first 5 min of exercise and glucose at the start of exercise was less than 182 mg/dL, it predicted hypoglycemia with 79.55% accuracy. Model 2 achieved a higher accuracy of 86.7% using additional features and higher complexity. CONCLUSIONS Models presented here can assist people with T1D to avoid exercise related hypoglycemia. The simple model 1 heuristic can be easily remembered (the 180/120 rule) and model 2 is more complex requiring computational resources, making it suitable for automated artificial pancreas or decision support systems.
Collapse
Affiliation(s)
- Ravi Reddy
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| | - Navid Resalat
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| | - Leah M. Wilson
- Department of Medicine, Division of Endocrinology, Harold Schnitzer Diabetes Health Center Oregon, Health & Science University, Portland, OR, USA
| | - Jessica R. Castle
- Department of Medicine, Division of Endocrinology, Harold Schnitzer Diabetes Health Center Oregon, Health & Science University, Portland, OR, USA
| | - Joseph El Youssef
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
- Department of Medicine, Division of Endocrinology, Harold Schnitzer Diabetes Health Center Oregon, Health & Science University, Portland, OR, USA
| | - Peter G. Jacobs
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
- Peter G. Jacobs, PhD, Department of Biomedical Engineering, Oregon Health & Science University, 3303 SW Bond Ave, Mailstop: 13B, Portland, OR 97239, USA.
| |
Collapse
|
11
|
Laguna Sanz AJ, Díez JL, Giménez M, Bondia J. Enhanced Accuracy of Continuous Glucose Monitoring during Exercise through Physical Activity Tracking Integration. SENSORS 2019; 19:s19173757. [PMID: 31480343 PMCID: PMC6749476 DOI: 10.3390/s19173757] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Revised: 08/21/2019] [Accepted: 08/27/2019] [Indexed: 12/11/2022]
Abstract
Current Continuous Glucose Monitors (CGM) exhibit increased estimation error during periods of aerobic physical activity. The use of readily-available exercise monitoring devices opens new possibilities for accuracy enhancement during these periods. The viability of an array of physical activity signals provided by three different wearable devices was considered. Linear regression models were used in this work to evaluate the correction capabilities of each of the wearable signals and propose a model for CGM correction during exercise. A simple two-input model can reduce CGM error during physical activity (17.46% vs. 13.8%, p < 0.005) to the magnitude of the baseline error level (13.61%). The CGM error is not worsened in periods without physical activity. The signals identified as optimal inputs for the model are "Mets" (Metabolic Equivalent of Tasks) from the Fitbit Charge HR device, which is a normalized measurement of energy expenditure, and the skin temperature reading provided by the Microsoft Band 2 device. A simpler one-input model using only "Mets" is also viable for a more immediate implementation of this correction into market devices.
Collapse
Affiliation(s)
- Alejandro José Laguna Sanz
- Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Instituto de Salud Carlos III, 28029 Madrid, Spain
| | - José Luis Díez
- Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Instituto de Salud Carlos III, 28029 Madrid, Spain
- Institut Universitari d'Automàtica i Informàtica Industrial, Universitat Politècnica de València, Camino de Vera, s/n, 46022 València, Spain
| | - Marga Giménez
- Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Instituto de Salud Carlos III, 28029 Madrid, Spain
- Diabetes Unit, Endocrinology and Nutrition Department, Hospital Clínic Universitari, IDIBAPS (Institut d'investigacions Biomèdiques August Pi i Sunyer), 08036 Barcelona, Spain
| | - Jorge Bondia
- Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Instituto de Salud Carlos III, 28029 Madrid, Spain.
- Institut Universitari d'Automàtica i Informàtica Industrial, Universitat Politècnica de València, Camino de Vera, s/n, 46022 València, Spain.
| |
Collapse
|
12
|
Abstract
IN BRIEF Automated insulin delivery (AID; also known as artificial pancreas) has improved the regulation of blood glucose concentrations, reduced the frequency of hyperglycemic and hypoglycemic episodes, and improved the quality of life of people with diabetes and their families. Three different types of algorithms-proportional-integral-derivative control, model predictive control, and fuzzy-logic knowledge-based systems-have been used in AID control systems. This article will highlight the foundations of these algorithms and discuss their strengths and limitations. Multivariable artificial pancreas and dual-hormone (insulin and glucagon) systems will be introduced.
Collapse
Affiliation(s)
- Ali Cinar
- Departments of Chemical and Biological Engineering and Biomedical Engineering, Engineering Center for Diabetes Research and Education, Illinois Institute of Technology, Chicago, IL
| |
Collapse
|
13
|
Kovatchev B. A Century of Diabetes Technology: Signals, Models, and Artificial Pancreas Control. Trends Endocrinol Metab 2019; 30:432-444. [PMID: 31151733 DOI: 10.1016/j.tem.2019.04.008] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2019] [Revised: 04/14/2019] [Accepted: 04/25/2019] [Indexed: 12/24/2022]
Abstract
Arguably, diabetes mellitus is one of the best-quantified human conditions: elaborate in silico models describe the action of the human metabolic system; real-time signals such as continuous glucose monitoring are readily available; insulin delivery is being automated; and control algorithms are capable of optimizing blood glucose fluctuation in patients' natural environments. The transition of the artificial pancreas (AP) to everyday clinical use is happening now, and is contingent upon seamless concerted work of devices encompassing the patient in a digital treatment ecosystem. This review recounts briefly the story of diabetes technology, which began a century ago with the discovery of insulin, progressed through glucose monitoring and subcutaneous insulin delivery, and is now rapidly advancing towards fully automated clinically viable AP systems.
Collapse
Affiliation(s)
- Boris Kovatchev
- University of Virginia School of Medicine, UVA Center for Diabetes Technology, Ivy Translational Research Building, 560 Ray C. Hunt Drive, Charlottesville, VA 22903-2981, USA.
| |
Collapse
|
14
|
Zaharieva DP, Turksoy K, McGaugh SM, Pooni R, Vienneau T, Ly T, Riddell MC. Lag Time Remains with Newer Real-Time Continuous Glucose Monitoring Technology During Aerobic Exercise in Adults Living with Type 1 Diabetes. Diabetes Technol Ther 2019; 21:313-321. [PMID: 31059282 PMCID: PMC6551983 DOI: 10.1089/dia.2018.0364] [Citation(s) in RCA: 81] [Impact Index Per Article: 16.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Background: Real-time continuous glucose monitoring (CGM) devices help detect glycemic excursions associated with exercise, meals, and insulin dosing in patients with type 1 diabetes (T1D). However, the delay between interstitial and blood glucose may result in CGM underestimating the true change in glycemia during activity. The purpose of this study was to examine CGM discrepancies during exercise and the meal postexercise versus self-monitoring of blood glucose (SMBG). Methods: Seventeen adults with T1D using insulin pump therapy and CGM completed 60 min of aerobic exercise on three occasions. A standardized meal was given 30 min postexercise. SMBG was measured during exercise and in recovery using OmniPod® Personal Diabetes Manager (PDM; Insulet, Billerica, MA) with built-in glucose meter (FreeStyle; Abbott Laboratories, Abbott Park, IL), while CGM was measured with Dexcom G4® with 505 algorithm (n = 4) or G5® (n = 13), which were calibrated with subjects' own PDM. Results: SMBG showed a large drop in glycemia during exercise, while CGM showed a lag of 12 ± 11 (mean ± standard deviation) minutes and bias of -7 ± 19 mg/dL/min during activity. Mean absolute relative difference (MARD) for CGM versus SMBG was 13 (6-22)% [median (interquartile range)] during exercise and 8 (5-14)% during mealtime. Clarke error grids showed CGM values were in zones A and B 94%-99% of the time for SMBG. Conclusion: In summary, the drop in CGM lags behind the drop in blood glucose during prolonged aerobic exercise by 12 ± 11 min, and MARD increases to 13 (6-22)% during exercise as well. Therefore, if hypoglycemia is suspected during exercise, individuals should confirm glucose levels with a capillary glucose measurement.
Collapse
Affiliation(s)
- Dessi P. Zaharieva
- Kinesiology and Health Science, Faculty of Health, Muscle Health Research Centre, York University, Toronto, Canada
| | - Kamuran Turksoy
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois
| | - Sarah M. McGaugh
- Kinesiology and Health Science, Faculty of Health, Muscle Health Research Centre, York University, Toronto, Canada
| | - Rubin Pooni
- Kinesiology and Health Science, Faculty of Health, Muscle Health Research Centre, York University, Toronto, Canada
| | | | - Trang Ly
- Insulet Corporation, Billerica, Massachusetts
| | - Michael C. Riddell
- Kinesiology and Health Science, Faculty of Health, Muscle Health Research Centre, York University, Toronto, Canada
- LMC Diabetes and Endocrinology, Toronto, Canada
| |
Collapse
|
15
|
Hajizadeh I, Rashid M, Cinar A. Plasma-Insulin-Cognizant Adaptive Model Predictive Control for Artificial Pancreas Systems. JOURNAL OF PROCESS CONTROL 2019; 77:97-113. [PMID: 31814659 PMCID: PMC6897508 DOI: 10.1016/j.jprocont.2019.03.009] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
An adaptive model predictive control (MPC) algorithm with dynamic adjustments of constraints and objective function weights based on estimates of the plasma insulin concentration (PIC) is proposed for artificial pancreas (AP) systems. A personalized compartment model that translates the infused insulin into estimates of PIC is integrated with a recursive subspace-based system identification to characterize the transient dynamics of glycemic measurements. The system identification approach is able to identify stable, reliable linear time-varying models from closed-loop data. An MPC algorithm using the adaptive models is designed to compute the optimal exogenous insulin delivery for AP systems without requiring any manually-entered meal information. A dynamic safety constraint derived from the estimation of PIC is incorporated in the adaptive MPC to improve the efficacy of the AP and prevent insulin overdosing. Simulation case studies demonstrate the performance of the proposed adaptive MPC algorithm.
Collapse
Affiliation(s)
- Iman Hajizadeh
- Dept of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL 60616
| | - Mudassir Rashid
- Dept of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL 60616
| | - Ali Cinar
- Dept of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL 60616
- Dept of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL 60616
- Correspondence concerning this article should be addressed to A. Cinar at
| |
Collapse
|
16
|
Feng J, Hajizadeh I, Yu X, Rashid M, Samadi S, Sevil M, Hobbs N, Brandt R, Lazaro C, Maloney Z, Littlejohn E, Quinn L, Cinar A. Multi-Model Sensor Fault Detection and Data Reconciliation: A Case Study with Glucose Concentration Sensors for Diabetes. AIChE J 2019; 65:629-639. [PMID: 31447487 PMCID: PMC6707739 DOI: 10.1002/aic.16435] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2018] [Indexed: 11/08/2022]
Abstract
Erroneous information from sensors affect process monitoring and control. An algorithm with multiple model identification methods will improve the sensitivity and accuracy of sensor fault detection and data reconciliation (SFD&DR). A novel SFD&DR algorithm with four types of models including outlier robust Kalman filter, locally weighted partial least squares, predictor-based subspace identification, and approximate linear dependency-based kernel recursive least squares is proposed. The residuals are further analyzed by artificial neural networks and a voting algorithm. The performance of the SFD&DR algorithm is illustrated by clinical data from artificial pancreas experiments with people with diabetes. The glucose-insulin metabolism has time-varying parameters and nonlinearities, providing a challenging system for fault detection and data reconciliation. Data from 17 clinical experiments collected over 896 hours were analyzed; the results indicate that the proposed SFD&DR algorithm is capable of detecting and diagnosing sensor faults and reconciling the erroneous sensor signals with better model-estimated values.
Collapse
Affiliation(s)
- Jianyuan Feng
- Dept. of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL 60616
| | - Iman Hajizadeh
- Dept. of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL 60616
| | - Xia Yu
- Dept. of Control Theory and Control Engineering, Northeastern University, Shenyang, Liaoning, China, 110819
| | - Mudassir Rashid
- Dept. of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL 60616
| | - Sediqeh Samadi
- Dept. of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL 60616
| | - Mert Sevil
- Dept. of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL 60616
| | - Nicole Hobbs
- Dept. of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL 60616
| | - Rachel Brandt
- Dept. of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL 60616
| | - Caterina Lazaro
- Dept. of Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL 60616
| | - Zacharie Maloney
- Dept. of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL 60616
| | | | - Laurie Quinn
- College of Nursing, University of Illinois at Chicago, Chicago, IL 60616
| | - Ali Cinar
- Dept. of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL 60616
- Dept. of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL 60616
| |
Collapse
|
17
|
Reddy RK, Pooni R, Zaharieva DP, Senf B, El Youssef J, Dassau E, Doyle Iii FJ, Clements MA, Rickels MR, Patton SR, Castle JR, Riddell MC, Jacobs PG. Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study. JMIR Mhealth Uhealth 2018; 6:e10338. [PMID: 30530451 PMCID: PMC6305876 DOI: 10.2196/10338] [Citation(s) in RCA: 90] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Revised: 06/17/2018] [Accepted: 09/05/2018] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Wrist-worn activity monitors are often used to monitor heart rate (HR) and energy expenditure (EE) in a variety of settings including more recently in medical applications. The use of real-time physiological signals to inform medical systems including drug delivery systems and decision support systems will depend on the accuracy of the signals being measured, including accuracy of HR and EE. Prior studies assessed accuracy of wearables only during steady-state aerobic exercise. OBJECTIVE The objective of this study was to validate the accuracy of both HR and EE for 2 common wrist-worn devices during a variety of dynamic activities that represent various physical activities associated with daily living including structured exercise. METHODS We assessed the accuracy of both HR and EE for two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) during dynamic activities. Over a 2-day period, 20 healthy adults (age: mean 27.5 [SD 6.0] years; body mass index: mean 22.5 [SD 2.3] kg/m2; 11 females) performed a maximal oxygen uptake test, free-weight resistance circuit, interval training session, and activities of daily living. Validity was assessed using an HR chest strap (Polar) and portable indirect calorimetry (Cosmed). Accuracy of the commercial wearables versus research-grade standards was determined using Bland-Altman analysis, correlational analysis, and error bias. RESULTS Fitbit and Garmin were reasonably accurate at measuring HR but with an overall negative bias. There was more error observed during high-intensity activities when there was a lack of repetitive wrist motion and when the exercise mode indicator was not used. The Garmin estimated HR with a mean relative error (RE, %) of -3.3% (SD 16.7), whereas Fitbit estimated HR with an RE of -4.7% (SD 19.6) across all activities. The highest error was observed during high-intensity intervals on bike (Fitbit: -11.4% [SD 35.7]; Garmin: -14.3% [SD 20.5]) and lowest error during high-intensity intervals on treadmill (Fitbit: -1.7% [SD 11.5]; Garmin: -0.5% [SD 9.4]). Fitbit and Garmin EE estimates differed significantly, with Garmin having less negative bias (Fitbit: -19.3% [SD 28.9], Garmin: -1.6% [SD 30.6], P<.001) across all activities, and with both correlating poorly with indirect calorimetry measures. CONCLUSIONS Two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) show good HR accuracy, with a small negative bias, and reasonable EE estimates during low to moderate-intensity exercise and during a variety of common daily activities and exercise. Accuracy was compromised markedly when the activity indicator was not used on the watch or when activities involving less wrist motion such as cycle ergometry were done.
Collapse
Affiliation(s)
- Ravi Kondama Reddy
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, United States
| | - Rubin Pooni
- School of Kinesiology and Health Science, York University, Toronto, ON, Canada
| | - Dessi P Zaharieva
- School of Kinesiology and Health Science, York University, Toronto, ON, Canada
| | - Brian Senf
- Harold Schnitzer Diabetes Health Center, Oregon Health & Science University, Portland, OR, United States
| | - Joseph El Youssef
- Harold Schnitzer Diabetes Health Center, Oregon Health & Science University, Portland, OR, United States
| | - Eyal Dassau
- Harvard John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, United States
| | - Francis J Doyle Iii
- Harvard John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, United States
| | - Mark A Clements
- Children's Mercy Kansas City, Kansas City, MO, United States
| | - Michael R Rickels
- Institute for Diabetes, Obesity & Metabolism, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA, United States
| | - Susana R Patton
- Department of Pediatrics, University of Kansas Medical Center, Kansas City, KS, United States
| | - Jessica R Castle
- Harold Schnitzer Diabetes Health Center, Oregon Health & Science University, Portland, OR, United States
| | - Michael C Riddell
- School of Kinesiology and Health Science, York University, Toronto, ON, Canada
| | - Peter G Jacobs
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, United States
| |
Collapse
|
18
|
Turksoy K, Hajizadeh I, Hobbs N, Kilkus J, Littlejohn E, Samadi S, Feng J, Sevil M, Lazaro C, Ritthaler J, Hibner B, Devine N, Quinn L, Cinar A. Multivariable Artificial Pancreas for Various Exercise Types and Intensities. Diabetes Technol Ther 2018; 20:662-671. [PMID: 30188192 PMCID: PMC6161329 DOI: 10.1089/dia.2018.0072] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND Exercise challenges people with type 1 diabetes in controlling their glucose concentration (GC). A multivariable adaptive artificial pancreas (MAAP) may lessen the burden. METHODS The MAAP operates without any user input and computes insulin based on continuous glucose monitor and physical activity signals. To analyze performance, 18 60-h closed-loop experiments with 96 exercise sessions with three different protocols were completed. Each day, the subjects completed one resistance and one treadmill exercise (moderate continuous training [MCT] or high-intensity interval training [HIIT]). The primary outcome is time spent in each glycemic range during the exercise + recovery period. Secondary measures include average GC and average change in GC during each exercise modality. RESULTS The GC during exercise + recovery periods were within the euglycemic range (70-180 mg/dL) for 69.9% of the time and within a safe glycemic range for exercise (70-250 mg/dL) for 93.0% of the time. The exercise sessions are defined to begin 30 min before the start of exercise and end 2 h after start of exercise. The GC were within the severe hypoglycemia (<55 mg/dL), moderate hypoglycemia (55-70 mg/dL), moderate hyperglycemia (180-250 mg/dL), and severe hyperglycemia (>250 mg/dL) for 0.9%, 1.3%, 23.1%, and 4.8% of the time, respectively. The average GC decline during exercise differed with exercise type (P = 0.0097) with a significant difference between the MCT and resistance (P = 0.0075). To prevent large GC decreases leading to hypoglycemia, MAAP recommended carbohydrates in 59% of MCT, 50% of HIIT, and 39% of resistance sessions. CONCLUSIONS A consistent GC decline occurred in exercise and recovery periods, which differed with exercise type. The average GC at the start of exercise was above target (185.5 ± 56.6 mg/dL for MCT, 166.9 ± 61.9 mg/dL for resistance training, and 171.7 ± 41.4 mg/dL HIIT), making a small decrease desirable. Hypoglycemic events occurred in 14.6% of exercise sessions and represented only 2.22% of the exercise and recovery period.
Collapse
Affiliation(s)
- Kamuran Turksoy
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois
| | - Iman Hajizadeh
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, Illinois
| | - Nicole Hobbs
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois
| | - Jennifer Kilkus
- Section of Endocrinology, Department of Pediatrics and Medicine, Kovler Diabetes Center, University of Chicago, Chicago, Illinois
| | - Elizabeth Littlejohn
- Section of Endocrinology, Department of Pediatrics and Medicine, Kovler Diabetes Center, University of Chicago, Chicago, Illinois
- Sparrow Medical Group/Michigan State University, Lansing, Michigan
| | - Sediqeh Samadi
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, Illinois
| | - Jianyuan Feng
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, Illinois
| | - Mert Sevil
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois
| | - Caterina Lazaro
- Department of Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, Illinois
| | - Julia Ritthaler
- Division of Biological Sciences, University of Chicago, Chicago, Illinois
| | - Brooks Hibner
- Division of Biological Sciences, University of Chicago, Chicago, Illinois
| | - Nancy Devine
- Section of Endocrinology, Department of Pediatrics and Medicine, Kovler Diabetes Center, University of Chicago, Chicago, Illinois
| | - Laurie Quinn
- College of Nursing, University of Illinois at Chicago, Chicago, Illinois
| | - Ali Cinar
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, Illinois
| |
Collapse
|
19
|
Hajizadeh I, Rashid M, Turksoy K, Samadi S, Feng J, Sevil M, Hobbs N, Lazaro C, Maloney Z, Littlejohn E, Cinar A. Incorporating Unannounced Meals and Exercise in Adaptive Learning of Personalized Models for Multivariable Artificial Pancreas Systems. J Diabetes Sci Technol 2018; 12:953-966. [PMID: 30060699 PMCID: PMC6134614 DOI: 10.1177/1932296818789951] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
BACKGROUND Despite the recent advancements in the modeling of glycemic dynamics for type 1 diabetes mellitus, automatically considering unannounced meals and exercise without manual user inputs remains challenging. METHOD An adaptive model identification technique that incorporates exercise information and estimates of the effects of unannounced meals obtained automatically without user input is proposed in this work. The effects of the unknown consumed carbohydrates are estimated using an individualized unscented Kalman filtering algorithm employing an augmented glucose-insulin dynamic model, and exercise information is acquired from noninvasive physiological measurements. The additional information on meals and exercise is incorporated with personalized estimates of plasma insulin concentration and glucose measurement data in an adaptive model identification algorithm. RESULTS The efficacy of the proposed personalized and adaptive modeling algorithm is demonstrated using clinical data involving closed-loop experiments of the artificial pancreas system, and the results demonstrate accurate glycemic modeling with the average root-mean-square error (mean absolute error) of 25.50 mg/dL (18.18 mg/dL) for six-step (30 minutes ahead) predictions. CONCLUSIONS The approach presented is able to identify reliable time-varying individualized glucose-insulin models.
Collapse
Affiliation(s)
- Iman Hajizadeh
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Mudassir Rashid
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Kamuran Turksoy
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Sediqeh Samadi
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Jianyuan Feng
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Mert Sevil
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Nicole Hobbs
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Caterina Lazaro
- Department of Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Zacharie Maloney
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Elizabeth Littlejohn
- Department of Pediatrics and Medicine, Section of Endocrinology, Kovler Diabetes Center, University of Chicago, Chicago, IL, USA
| | - Ali Cinar
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
- Ali Cinar, PhD, Illinois Institute of Technology, Department of Chemical and Biological Engineering, 10 W 33rd St, Chicago, IL 60616, USA.
| |
Collapse
|
20
|
Houlder SK, Yardley JE. Continuous Glucose Monitoring and Exercise in Type 1 Diabetes: Past, Present and Future. BIOSENSORS-BASEL 2018; 8:bios8030073. [PMID: 30081478 PMCID: PMC6165159 DOI: 10.3390/bios8030073] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Revised: 07/31/2018] [Accepted: 08/01/2018] [Indexed: 12/29/2022]
Abstract
Prior to the widespread use of continuous glucose monitoring (CGM), knowledge of the effects of exercise in type 1 diabetes (T1D) was limited to the exercise period, with few studies having the budget or capacity to monitor participants overnight. Recently, CGM has become a staple of many exercise studies, allowing researchers to observe the otherwise elusive late post-exercise period. We performed a strategic search using PubMed and Academic Search Complete. Studies were included if they involved adults with T1D performing exercise or physical activity, had a sample size greater than 5, and involved the use of CGM. Upon completion of the search protocol, 26 articles were reviewed for inclusion. While outcomes have been variable, CGM use in exercise studies has allowed the assessment of post-exercise (especially nocturnal) trends for different exercise modalities in individuals with T1D. Sensor accuracy is currently considered adequate for exercise, which has been crucial to developing closed-loop and artificial pancreas systems. Until these systems are perfected, CGM continues to provide information about late post-exercise responses, to assist T1D patients in managing their glucose, and to be useful as a tool for teaching individuals with T1D about exercise.
Collapse
Affiliation(s)
- Shaelyn K Houlder
- Augustana Faculty, University of Alberta, 4901-46 Ave, Camrose, AB T4V 2R3, Canada.
| | - Jane E Yardley
- Augustana Faculty, University of Alberta, 4901-46 Ave, Camrose, AB T4V 2R3, Canada.
- Alberta Diabetes Institute, 112 St. NW, Edmonton, AB T6G 2T9, Canada.
| |
Collapse
|
21
|
Castle JR, El Youssef J, Wilson LM, Reddy R, Resalat N, Branigan D, Ramsey K, Leitschuh J, Rajhbeharrysingh U, Senf B, Sugerman SM, Gabo V, Jacobs PG. Randomized Outpatient Trial of Single- and Dual-Hormone Closed-Loop Systems That Adapt to Exercise Using Wearable Sensors. Diabetes Care 2018; 41:1471-1477. [PMID: 29752345 PMCID: PMC6014543 DOI: 10.2337/dc18-0228] [Citation(s) in RCA: 104] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Accepted: 04/13/2018] [Indexed: 02/03/2023]
Abstract
OBJECTIVE Automated insulin delivery is the new standard for type 1 diabetes, but exercise-related hypoglycemia remains a challenge. Our aim was to determine whether a dual-hormone closed-loop system using wearable sensors to detect exercise and adjust dosing to reduce exercise-related hypoglycemia would outperform other forms of closed-loop and open-loop therapy. RESEARCH DESIGN AND METHODS Participants underwent four arms in randomized order: dual-hormone, single-hormone, predictive low glucose suspend, and continuation of current care over 4 outpatient days. Each arm included three moderate-intensity aerobic exercise sessions. The two primary outcomes were percentage of time in hypoglycemia (<70 mg/dL) and in a target range (70-180 mg/dL) assessed across the entire study and from the start of the in-clinic exercise until the next meal. RESULTS The analysis included 20 adults with type 1 diabetes who completed all arms. The mean time (SD) in hypoglycemia was the lowest with dual-hormone during the exercise period: 3.4% (4.5) vs. 8.3% (12.6) single-hormone (P = 0.009) vs. 7.6% (8.0) predictive low glucose suspend (P < 0.001) vs. 4.3% (6.8) current care where pre-exercise insulin adjustments were allowed (P = 0.49). Time in hypoglycemia was also the lowest with dual-hormone during the entire 4-day study: 1.3% (1.0) vs. 2.8% (1.7) single-hormone (P < 0.001) vs. 2.0% (1.5) predictive low glucose suspend (P = 0.04) vs. 3.1% (3.2) current care (P = 0.007). Time in range during the entire study was the highest with single-hormone: 74.3% (8.0) vs. 72.0% (10.8) dual-hormone (P = 0.44). CONCLUSIONS The addition of glucagon delivery to a closed-loop system with automated exercise detection reduces hypoglycemia in physically active adults with type 1 diabetes.
Collapse
Affiliation(s)
- Jessica R Castle
- Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR
| | - Joseph El Youssef
- Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR.,Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR
| | - Leah M Wilson
- Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR
| | - Ravi Reddy
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR
| | - Navid Resalat
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR
| | - Deborah Branigan
- Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR
| | - Katrina Ramsey
- Oregon Clinical and Translational Research Institute Biostatistics & Design Program, Oregon Health & Science University, Portland, OR
| | - Joseph Leitschuh
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR
| | - Uma Rajhbeharrysingh
- Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR
| | - Brian Senf
- Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR
| | - Samuel M Sugerman
- Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR
| | - Virginia Gabo
- Harold Schnitzer Diabetes Health Center, Division of Endocrinology, Oregon Health & Science University, Portland, OR
| | - Peter G Jacobs
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR
| |
Collapse
|
22
|
Hajizadeh I, Rashid M, Samadi S, Feng J, Sevil M, Hobbs N, Lazaro C, Maloney Z, Brandt R, Yu X, Turksoy K, Littlejohn E, Cengiz E, Cinar A. Adaptive and Personalized Plasma Insulin Concentration Estimation for Artificial Pancreas Systems. J Diabetes Sci Technol 2018; 12:639-649. [PMID: 29566547 PMCID: PMC6154239 DOI: 10.1177/1932296818763959] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND The artificial pancreas (AP) system, a technology that automatically administers exogenous insulin in people with type 1 diabetes mellitus (T1DM) to regulate their blood glucose concentrations, necessitates the estimation of the amount of active insulin already present in the body to avoid overdosing. METHOD An adaptive and personalized plasma insulin concentration (PIC) estimator is designed in this work to accurately quantify the insulin present in the bloodstream. The proposed PIC estimation approach incorporates Hovorka's glucose-insulin model with the unscented Kalman filtering algorithm. Methods for the personalized initialization of the time-varying model parameters to individual patients for improved estimator convergence are developed. Data from 20 three-days-long closed-loop clinical experiments conducted involving subjects with T1DM are used to evaluate the proposed PIC estimation approach. RESULTS The proposed methods are applied to the clinical data containing significant disturbances, such as unannounced meals and exercise, and the results demonstrate the accurate real-time estimation of the PIC with the root mean square error of 7.15 and 9.25 mU/L for the optimization-based fitted parameters and partial least squares regression-based testing parameters, respectively. CONCLUSIONS The accurate real-time estimation of PIC will benefit the AP systems by preventing overdelivery of insulin when significant insulin is present in the bloodstream.
Collapse
Affiliation(s)
- Iman Hajizadeh
- Department of Chemical and Biological
Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Mudassir Rashid
- Department of Chemical and Biological
Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Sediqeh Samadi
- Department of Chemical and Biological
Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Jianyuan Feng
- Department of Chemical and Biological
Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Mert Sevil
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Nicole Hobbs
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Caterina Lazaro
- Department of Electrical and Computer
Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Zacharie Maloney
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Rachel Brandt
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Xia Yu
- School of Information Science and
Technology, Northeastern University, Shenyang, China
| | - Kamuran Turksoy
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Elizabeth Littlejohn
- Department of Pediatrics and Medicine,
Section of Endocrinology, Kovler Diabetes Center, University of Chicago, Chicago,
IL, USA
| | - Eda Cengiz
- Department of Pediatrics, Yale
University School of Medicine, New Haven, CT, USA
| | - Ali Cinar
- Department of Chemical and Biological
Engineering, Illinois Institute of Technology, Chicago, IL, USA
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
- Ali Cinar, PhD, Illinois Institute of
Technology, Department of Chemical and Biological Engineering, 10 W 33rd St,
Chicago, IL 60616, USA.
| |
Collapse
|
23
|
Feng J, Hajizadeh I, Yu X, Rashid M, Turksoy K, Samadi S, Sevil M, Hobbs N, Brandt R, Lazaro C, Maloney Z, Littlejohn E, Philipson LH, Cinar A. Multi-level Supervision and Modification of Artificial Pancreas Control System. Comput Chem Eng 2018; 112:57-69. [PMID: 30287976 PMCID: PMC6166877 DOI: 10.1016/j.compchemeng.2018.02.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Artificial pancreas (AP) systems provide automated regulation of blood glucose concentration (BGC) for people with type 1 diabetes (T1D). An AP includes three components: a continuous glucose monitoring (CGM) sensor, a controller calculating insulin infusion rate based on the CGM signal, and a pump delivering the insulin amount calculated by the controller to the patient. The performance of the AP system depends on successful operation of these three components. Many APs use model predictive controllers that rely on models to predict BGC and to calculate the optimal insulin infusion rate. The performance of model-based controllers depends on the accuracy of the models that is affected by large dynamic changes in glucose-insulin metabolism or equipment performance that may move the operating conditions away from those used in developing the models and designing the control system. Sensor errors and missing signals will cause calculation of erroneous insulin infusion rates. And the performance of the controller may vary at each sampling step and each period (meal, exercise, and sleep), and from day to day. Here we describe a multi-level supervision and controller modification (ML-SCM) module is developed to supervise the performance of the AP system and retune the controller. It supervises AP performance in 3 time windows: sample level, period level, and day level. At sample level, an online controller performance assessment sub-module will generate controller performance indexes to evaluate various components of the AP system and conservatively modify the controller. A sensor error detection and signal reconciliation module will detect sensor error and reconcile the CGM sensor signal at each sample. At period level, the controller performance is evaluated with information collected during a certain time period and the controller is tuned more aggressively. At the day level, the daily CGM ranges are further analyzed to determine the adjustable range of controller parameters used for sample level and period level. Thirty subjects in the UVa/Padova metabolic simulator were used to evaluate the performance of the ML-SCM module and one clinical experiment is used to illustrate its performance in a clinical environment. The results indicate that the AP system with an ML-SCM module has a safer range of glucose concentration distribution and more appropriate insulin infusion rate suggestions than an AP system without the ML-SCM module.
Collapse
Affiliation(s)
- Jianyuan Feng
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Iman Hajizadeh
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Xia Yu
- Department of Control Theory and Control Engineering, Northeastern University, Shenyang, Liaoning China
| | - Mudassir Rashid
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Kamuran Turksoy
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Sediqeh Samadi
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Mert Sevil
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Nicole Hobbs
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Rachel Brandt
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Caterina Lazaro
- Department of Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Zacharie Maloney
- Department of Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | | | - Louis H Philipson
- Departments of Medicine and Pediatrics - Section of Endocrinology, University of Chicago, Chicago, IL, USA
| | - Ali Cinar
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| |
Collapse
|
24
|
|
25
|
Perry B, Herrington W, Goldsack JC, Grandinetti CA, Vasisht KP, Landray MJ, Bataille L, DiCicco RA, Bradley C, Narayan A, Papadopoulos EJ, Sheth N, Skodacek K, Stem K, Strong TV, Walton MK, Corneli A. Use of Mobile Devices to Measure Outcomes in Clinical Research, 2010-2016: A Systematic Literature Review. Digit Biomark 2018; 2:11-30. [PMID: 29938250 PMCID: PMC6008882 DOI: 10.1159/000486347] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2017] [Accepted: 12/13/2017] [Indexed: 01/08/2023] Open
Abstract
Background The use of mobile devices in clinical research has advanced substantially in recent years due to the rapid pace of technology development. With an overall aim of informing the future use of mobile devices in interventional clinical research to measure primary outcomes, we conducted a systematic review of the use of and clinical outcomes measured by mobile devices (mobile outcomes) in observational and interventional clinical research. Method We conducted a PubMed search using a range of search terms to retrieve peer-reviewed articles on clinical research published between January 2010 and May 2016 in which mobile devices were used to measure study outcomes. We screened each publication for specific inclusion and exclusion criteria. We then identified and qualitatively summarized the use of mobile outcome assessments in clinical research, including the type and design of the study, therapeutic focus, type of mobile device(s) used, and specific mobile outcomes reported. Results The search retrieved 2,530 potential articles of interest. After screening, 88 publications remained. Twenty-five percent of the publications (n = 22) described mobile outcomes used in interventional research, and the rest (n = 66) described observational clinical research. Thirteen therapeutic areas were represented. Five categories of mobile devices were identified: (1) inertial sensors, (2) biosensors, (3) pressure sensors and walkways, (4) medication adherence monitors, and (5) location monitors; inertial sensors/accelerometers were most common (reported in 86% of the publications). Among the variety of mobile outcomes, various assessments of physical activity were most common (reported in 74% of the publications). Other mobile outcomes included assessments of sleep, mobility, and pill adherence, as well as biomarkers assessed using a mobile device, including cardiac measures, glucose, gastric reflux, respiratory measures, and intensity of head-related injury. Conclusion Mobile devices are being widely used in clinical research to assess outcomes, although their use in interventional research to assess therapeutic effectiveness is limited. For mobile devices to be used more frequently in pivotal interventional research – such as trials informing regulatory decision-making – more focus should be placed on: (1) consolidating the evidence supporting the clinical meaningfulness of specific mobile outcomes, and (2) standardizing the use of mobile devices in clinical research to measure specific mobile outcomes (e.g., data capture frequencies, placement of device). To that aim, this manuscript offers a broad overview of the various mobile outcome assessments currently used in observational and interventional research, and categorizes and consolidates this information for researchers interested in using mobile devices to assess outcomes in interventional research.
Collapse
Affiliation(s)
- Brian Perry
- Department of Population Health Sciences, Duke University School of Medicine, Durham, North Carolina, USA.,Clinical Trials Transformation Initiative, Durham, North Carolina, USA
| | - Will Herrington
- Nuffield Department of Population Health, University of Oxford, Oxford, United Kingdom
| | - Jennifer C Goldsack
- Clinical Trials Transformation Initiative, Durham, North Carolina, USA.,Duke Clinical Research Institute, Durham, North Carolina, USA
| | - Cheryl A Grandinetti
- Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland, USA
| | - Kaveeta P Vasisht
- Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland, USA
| | - Martin J Landray
- Nuffield Department of Population Health, University of Oxford, Oxford, United Kingdom
| | - Lauren Bataille
- The Michael J. Fox Foundation for Parkinson's Research, New York, New York, USA
| | | | - Corey Bradley
- Duke University Hospital, Durham, North Carolina, USA
| | | | - Elektra J Papadopoulos
- Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland, USA
| | - Nirav Sheth
- MicroMedicine, Watertown, Massachusetts, USA
| | - Ken Skodacek
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, USA
| | | | | | - Marc K Walton
- Janssen Research and Development, Titusville, New Jersey, USA
| | - Amy Corneli
- Department of Population Health Sciences, Duke University School of Medicine, Durham, North Carolina, USA.,Clinical Trials Transformation Initiative, Durham, North Carolina, USA
| |
Collapse
|
26
|
Bertachi A, Ramkissoon CM, Bondia J, Vehí J. Automated blood glucose control in type 1 diabetes: A review of progress and challenges. ACTA ACUST UNITED AC 2017; 65:172-181. [PMID: 29279252 DOI: 10.1016/j.endinu.2017.10.011] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2017] [Revised: 10/11/2017] [Accepted: 10/21/2017] [Indexed: 12/27/2022]
Abstract
Since the 2000s, research teams worldwide have been working to develop closed-loop (CL) systems able to automatically control blood glucose (BG) levels in patients with type 1 diabetes. This emerging technology is known as artificial pancreas (AP), and its first commercial version just arrived in the market. The main objective of this paper is to present an extensive review of the clinical trials conducted since 2011, which tested various implementations of the AP for different durations under varying conditions. A comprehensive table that contains key information from the selected publications is provided, and the main challenges in AP development and the mitigation strategies used are discussed. The development timelines for different AP systems are also included, highlighting the main evolutions over the clinical trials for each system.
Collapse
Affiliation(s)
- Arthur Bertachi
- Institute of Informatics and Applications, University of Girona, Campus de Montilivi, s/n, Edifici P4, 17071 Girona, Spain; Federal University of Technology - Paraná (UTFPR), Guarapuava, Avenida Professora Laura Pacheco Bastos 800, 85053-525 Guarapuava, Paraná, Brazil
| | - Charrise M Ramkissoon
- Institute of Informatics and Applications, University of Girona, Campus de Montilivi, s/n, Edifici P4, 17071 Girona, Spain
| | - Jorge Bondia
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, Camino de Vera, s/n, Edificio 8G, 46022 Valencia, Spain
| | - Josep Vehí
- Institute of Informatics and Applications, University of Girona, Campus de Montilivi, s/n, Edifici P4, 17071 Girona, Spain.
| |
Collapse
|
27
|
Hajizadeh I, Rashid M, Turksoy K, Samadi S, Feng J, Frantz N, Sevil M, Cengiz E, Cinar A. Plasma Insulin Estimation in People with Type 1 Diabetes Mellitus. Ind Eng Chem Res 2017. [DOI: 10.1021/acs.iecr.7b01618] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
| | | | | | | | | | | | | | - Eda Cengiz
- Department
of Pediatrics, Yale University School of Medicine, New Haven, Connecticut 06437-2411, United States
| | | |
Collapse
|
28
|
Abstract
PURPOSE OF REVIEW The review summarizes the current state of the artificial pancreas (AP) systems and introduces various new modules that should be included in future AP systems. RECENT FINDINGS A fully automated AP must be able to detect and mitigate the effects of meals, exercise, stress and sleep on blood glucose concentrations. This can only be achieved by using a multivariable approach that leverages information from wearable devices that provide real-time streaming data about various physiological variables that indicate imminent changes in blood glucose concentrations caused by meals, exercise, stress and sleep. The development of a fully automated AP will necessitate the design of multivariable and adaptive systems that use information from wearable devices in addition to glucose sensors and modify the models used in their model-predictive alarm and control systems to adapt to the changes in the metabolic state of the user. These AP systems will also integrate modules for controller performance assessment, fault detection and diagnosis, machine learning and classification to interpret various signals and achieve fault-tolerant control. Advances in wearable devices, computational power, and safe and secure communications are enabling the development of fully automated multivariable AP systems.
Collapse
Affiliation(s)
- Ali Cinar
- Department of Chemical and Biological Engineering and Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA.
| |
Collapse
|
29
|
Turksoy K, Frantz N, Quinn L, Dumin M, Kilkus J, Hibner B, Cinar A, Littlejohn E. Automated Insulin Delivery-The Light at the End of the Tunnel. J Pediatr 2017; 186:17-28.e9. [PMID: 28396030 DOI: 10.1016/j.jpeds.2017.02.055] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2016] [Revised: 02/13/2017] [Accepted: 02/20/2017] [Indexed: 12/28/2022]
Affiliation(s)
- Kamuran Turksoy
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL
| | - Nicole Frantz
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL
| | - Laurie Quinn
- College of Nursing, University of Illinois at Chicago, Chicago, IL
| | - Magdalena Dumin
- Biological Sciences Division, University of Chicago, Chicago, IL
| | - Jennifer Kilkus
- Biological Sciences Division, University of Chicago, Chicago, IL
| | - Brooks Hibner
- Biological Sciences Division, University of Chicago, Chicago, IL
| | - Ali Cinar
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL; Biological Sciences Division, University of Chicago, Chicago, IL; Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL
| | | |
Collapse
|
30
|
Christiansen SC, Fougner AL, Stavdahl Ø, Kölle K, Ellingsen R, Carlsen SM. A Review of the Current Challenges Associated with the Development of an Artificial Pancreas by a Double Subcutaneous Approach. Diabetes Ther 2017; 8:489-506. [PMID: 28503717 PMCID: PMC5446388 DOI: 10.1007/s13300-017-0263-6] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Indexed: 01/01/2023] Open
Abstract
INTRODUCTION Patients with diabetes type 1 (DM1) struggle daily to achieve good glucose control. The last decade has seen a rush of research groups working towards an artificial pancreas (AP) through the application of a double subcutaneous approach, i.e., subcutaneous (SC) continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusion. Few have focused on the fundamental limitations of this approach, especially regarding outcome measures beyond time in range. METHODS Based on insulin physiology, the limitations of CGM, SC insulin absorption, meal challenge, and physical activity in DM1 patients, we discuss the limitations of the double SC approach. Finally, we discuss safety measures and the achievements reported in some recent AP studies that have utilized the double SC approach. RESULTS Most studies show that a double SC AP increases the time in range compared to a sensor-augmented insulin pump and shortens the time in hypoglycemia. Despite these achievements, the proportion of time spent in hyperglycemia is still roughly 20-40%, and hypoglycemia is still present 1-4% of the time. The main factors limiting further progress are the latency of SC CGM (at least 5-10 min) and the slow pharmacokinetics of SC-delivered fast-acting insulin. The maximum blood insulin level is reached after 45 min and the maximum glucose-lowering effect is observed after 1.5-2 h, while the glucose-lowering effect lasts for at least 5 h. CONCLUSIONS Although using a double SC AP leads to significant improvements in glucose control, the SC approach has severe limitations that hamper further progress towards a robust AP.
Collapse
Affiliation(s)
- Sverre Christian Christiansen
- Department of Endocrinology, St Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.
- Department of Cancer Research and Molecular Medicine, Norwegian University of Science and Technology (NTNU), Trondheim, Norway.
| | - Anders Lyngvi Fougner
- Department of Engineering Cybernetics, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
- Central Norway Regional Health Authority, Stjørdal, Norway
| | - Øyvind Stavdahl
- Department of Engineering Cybernetics, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | - Konstanze Kölle
- Department of Engineering Cybernetics, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
- Central Norway Regional Health Authority, Stjørdal, Norway
| | - Reinold Ellingsen
- Department of Electronic Systems, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | - Sven Magnus Carlsen
- Department of Endocrinology, St Olavs Hospital, Trondheim University Hospital, Trondheim, Norway
- Department of Cancer Research and Molecular Medicine, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| |
Collapse
|
31
|
Use of Wearable Sensors and Biometric Variables in an Artificial Pancreas System. SENSORS 2017; 17:s17030532. [PMID: 28272368 PMCID: PMC5375818 DOI: 10.3390/s17030532] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2016] [Revised: 03/02/2017] [Accepted: 03/03/2017] [Indexed: 01/26/2023]
Abstract
An artificial pancreas (AP) computes the optimal insulin dose to be infused through an insulin pump in people with Type 1 Diabetes (T1D) based on information received from a continuous glucose monitoring (CGM) sensor. It has been recognized that exercise is a major challenge in the development of an AP system. The use of biometric physiological variables in an AP system may be beneficial for prevention of exercise-induced challenges and better glucose regulation. The goal of the present study is to find a correlation between biometric variables such as heart rate (HR), heat flux (HF), skin temperature (ST), near-body temperature (NBT), galvanic skin response (GSR), and energy expenditure (EE), 2D acceleration-mean of absolute difference (MAD) and changes in glucose concentrations during exercise via partial least squares (PLS) regression and variable importance in projection (VIP) in order to determine which variables would be most useful to include in a future artificial pancreas. PLS and VIP analyses were performed on data sets that included seven different types of exercises. Data were collected from 26 clinical experiments. Clinical results indicate ST to be the most consistently important (important for six out of seven tested exercises) variable over all different exercises tested. EE and HR are also found to be important variables over several types of exercise. We also found that the importance of GSR and NBT observed in our experiments might be related to stress and the effect of changes in environmental temperature on glucose concentrations. The use of the biometric measurements in an AP system may provide better control of glucose concentration.
Collapse
|
32
|
Graf A, McAuley SA, Sims C, Ulloa J, Jenkins AJ, Voskanyan G, O’Neal DN. Moving Toward a Unified Platform for Insulin Delivery and Sensing of Inputs Relevant to an Artificial Pancreas. J Diabetes Sci Technol 2017; 11:308-314. [PMID: 28264192 PMCID: PMC5478040 DOI: 10.1177/1932296816682762] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Advances in insulin pump and continuous glucose monitoring technology have primarily focused on optimizing glycemic control for people with type 1 diabetes. There remains a need to identify ways to minimize the physical burden of this technology. A unified platform with closely positioned or colocalized interstitial fluid glucose sensing and hormone delivery components is a potential solution. Present challenges to combining these components are interference of glucose sensing from proximate insulin delivery and the large discrepancy between the life span of current insulin infusion sets and glucose sensors. Addressing these concerns is of importance given that the future physical burden of this technology is likely to be even greater with the ongoing development of the artificial pancreas, potentially incorporating multiple hormone delivery, glucose sensing redundancy, and sensing of other clinically relevant nonglucose biochemical inputs.
Collapse
Affiliation(s)
- Anneke Graf
- Department of Endocrinology & Diabetes, St Vincent’s Hospital Melbourne, Melbourne, Australia
- Department of Medicine, University of Melbourne, Melbourne, Australia
| | - Sybil A. McAuley
- Department of Endocrinology & Diabetes, St Vincent’s Hospital Melbourne, Melbourne, Australia
- Department of Medicine, University of Melbourne, Melbourne, Australia
| | - Catriona Sims
- Department of Medicine, University of Melbourne, Melbourne, Australia
| | | | - Alicia J. Jenkins
- Department of Endocrinology & Diabetes, St Vincent’s Hospital Melbourne, Melbourne, Australia
- Department of Medicine, University of Melbourne, Melbourne, Australia
- NHMRC Clinical Trials Centre, Sydney, Australia
| | | | - David N. O’Neal
- Department of Endocrinology & Diabetes, St Vincent’s Hospital Melbourne, Melbourne, Australia
- Department of Medicine, University of Melbourne, Melbourne, Australia
- David N. O’Neal, MBBS, MD, Department of Medicine, University of Melbourne, 29 Regent St, Fitzroy, Melbourne, VIC 3065, Australia.
| |
Collapse
|
33
|
Ramkissoon CM, Aufderheide B, Bequette BW, Vehi J. A Review of Safety and Hazards Associated With the Artificial Pancreas. IEEE Rev Biomed Eng 2017; 10:44-62. [DOI: 10.1109/rbme.2017.2749038] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
34
|
Patel NS, Van Name MA, Cengiz E, Carria LR, Tichy EM, Weyman K, Weinzimer SA, Tamborlane WV, Sherr JL. Mitigating Reductions in Glucose During Exercise on Closed-Loop Insulin Delivery: The Ex-Snacks Study. Diabetes Technol Ther 2016; 18:794-799. [PMID: 27996320 PMCID: PMC5178000 DOI: 10.1089/dia.2016.0311] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
OBJECTIVE To assess whether snacking could be used with closed-loop (CL) insulin delivery to avoid exercise-induced reductions in plasma glucose (PG), as well as elevations in PG at the end of exercise. RESEARCH DESIGN AND METHODS Twelve type 1 diabetes (T1D) subjects (age 13-36 years, duration 10.7 ± 8.4 years, A1c 7.4% ± 0.8% [57 ± 8.7 mmol/mol]) underwent two 105-min exercise studies while under CL control: CL alone and CL+snack. Exercise, commenced at 3 PM, consisted of four 15-min periods of brisk treadmill walking to 65%-70% HRmax (separated by three 5-min rest periods), followed by a 30-min recovery period. Fifteen to 30 g carbohydrate (Gatorade) was provided on snacking visits just before and midway through the exercise period. PG and insulin were measured every 15-20 min during the exercise studies. RESULTS Baseline PG levels were similar for CL alone (164 ± 16 mg/dL) versus CL+snack (172 ± 11 mg/dL). During exercise, PG levels fell by 53 ± 10 mg/dL without snacking versus a modest 10 ± 13 mg/dL increase in PG with snacking (P = 0.0005); similar differences in the change in PG levels were observed at the end of recovery period. Hypoglycemia requiring rescue treatment (PG ≤60 mg/dL) during exercise occurred in three nonsnacking visits versus none with snacking. During the 75-min exercise period, insulin delivered was 1.8 ± 0.4 U for the CL+snack admission compared to 0.7 ± 0.1 U during CL alone (P = 0.002). CONCLUSION These results support the use of a simple snacking strategy to avoid exercise-induced lowering of PG while on CL insulin delivery. Persistent insulin infusion during exercise with snacking also appears to be effective in limiting increases in PG at the end of exercise.
Collapse
Affiliation(s)
- Neha S Patel
- Yale School of Medicine , Yale Pediatric Endocrinology & Diabetes, New Haven, Connecticut
| | - Michelle A Van Name
- Yale School of Medicine , Yale Pediatric Endocrinology & Diabetes, New Haven, Connecticut
| | - Eda Cengiz
- Yale School of Medicine , Yale Pediatric Endocrinology & Diabetes, New Haven, Connecticut
| | - Lori R Carria
- Yale School of Medicine , Yale Pediatric Endocrinology & Diabetes, New Haven, Connecticut
| | - Eileen M Tichy
- Yale School of Medicine , Yale Pediatric Endocrinology & Diabetes, New Haven, Connecticut
| | - Kate Weyman
- Yale School of Medicine , Yale Pediatric Endocrinology & Diabetes, New Haven, Connecticut
| | - Stuart A Weinzimer
- Yale School of Medicine , Yale Pediatric Endocrinology & Diabetes, New Haven, Connecticut
| | - William V Tamborlane
- Yale School of Medicine , Yale Pediatric Endocrinology & Diabetes, New Haven, Connecticut
| | - Jennifer L Sherr
- Yale School of Medicine , Yale Pediatric Endocrinology & Diabetes, New Haven, Connecticut
| |
Collapse
|
35
|
Turksoy K, Kilkus J, Hajizadeh I, Samadi S, Feng J, Sevil M, Lazaro C, Frantz N, Littlejohn E, Cinar A. Hypoglycemia Detection and Carbohydrate Suggestion in an Artificial Pancreas. J Diabetes Sci Technol 2016; 10:1236-1244. [PMID: 27464755 PMCID: PMC5094335 DOI: 10.1177/1932296816658666] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Fear of hypoglycemia is a major concern for many patients with type 1 diabetes and affects patient decisions for use of an artificial pancreas system. We propose an alternative way for prevention of hypoglycemia by issuing predictive hypoglycemia alarms and encouraging patients to consume carbohydrates in a timely manner. The algorithm has been tested on 6 subjects (3 males and 3 females, age 24.2 ± 4.5 years, weight 79.2 ± 16.2 kg, height 172.7 ± 9.4 cm, HbA1C 7.3 ± 0.48%, duration of diabetes 209.2 ± 87.9 months) over 3-day closed-loop clinical experiments as part of a multivariable artificial pancreas control system. Over 6 three-day clinical experiments, there were only 5 real hypoglycemia episodes, of which only 1 hypoglycemia episode occurred due to being missed by the proposed algorithm. The average hypoglycemia alarms per day and per subject was 3. Average glucose value when the first alarms were triggered was recorded to be 117 ± 30.6 mg/dl. Average carbohydrate consumption per alarm was 14 ± 7.8 grams. Our results have shown that most low glucose concentrations can be predicted in advance and the glucose levels can be raised back to the desired levels by consuming an appropriate amount of carbohydrate. The proposed algorithm is able to prevent most hypoglycemic events by suggesting appropriate levels of carbohydrate consumption before the actual occurrence of hypoglycemia.
Collapse
Affiliation(s)
- Kamuran Turksoy
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Jennifer Kilkus
- Department of Pediatrics and Medicine, Section of Endocrinology, Kovler Diabetes Center, University of Chicago, Chicago, IL, USA
| | - Iman Hajizadeh
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Sediqeh Samadi
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Jianyuan Feng
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Mert Sevil
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Caterina Lazaro
- Department of Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Nicole Frantz
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Elizabeth Littlejohn
- Department of Pediatrics and Medicine, Section of Endocrinology, Kovler Diabetes Center, University of Chicago, Chicago, IL, USA
| | - Ali Cinar
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
- Department of Pediatrics and Medicine, Section of Endocrinology, Kovler Diabetes Center, University of Chicago, Chicago, IL, USA
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| |
Collapse
|
36
|
Jacobs PG, El Youssef J, Reddy R, Resalat N, Branigan D, Condon J, Preiser N, Ramsey K, Jones M, Edwards C, Kuehl K, Leitschuh J, Rajhbeharrysingh U, Castle JR. Randomized trial of a dual-hormone artificial pancreas with dosing adjustment during exercise compared with no adjustment and sensor-augmented pump therapy. Diabetes Obes Metab 2016; 18:1110-1119. [PMID: 27333970 PMCID: PMC5056819 DOI: 10.1111/dom.12707] [Citation(s) in RCA: 88] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2016] [Revised: 06/08/2016] [Accepted: 06/12/2016] [Indexed: 11/30/2022]
Abstract
AIMS To test whether adjusting insulin and glucagon in response to exercise within a dual-hormone artificial pancreas (AP) reduces exercise-related hypoglycaemia. MATERIALS AND METHODS In random order, 21 adults with type 1 diabetes (T1D) underwent three 22-hour experimental sessions: AP with exercise dosing adjustment (APX); AP with no exercise dosing adjustment (APN); and sensor-augmented pump (SAP) therapy. After an overnight stay and 2 hours after breakfast, participants exercised for 45 minutes at 60% of their maximum heart rate, with no snack given before exercise. During APX, insulin was decreased and glucagon was increased at exercise onset, while during SAP therapy, subjects could adjust dosing before exercise. The two primary outcomes were percentage of time spent in hypoglycaemia (<3.9 mmol/L) and percentage of time spent in euglycaemia (3.9-10 mmol/L) from the start of exercise to the end of the study. RESULTS The mean (95% confidence interval) times spent in hypoglycaemia (<3.9 mmol/L) after the start of exercise were 0.3% (-0.1, 0.7) for APX, 3.1% (0.8, 5.3) for APN, and 0.8% (0.1, 1.4) for SAP therapy. There was an absolute difference of 2.8% less time spent in hypoglycaemia for APX versus APN (p = .001) and 0.5% less time spent in hypoglycaemia for APX versus SAP therapy (p = .16). Mean time spent in euglycaemia was similar across the different sessions. CONCLUSIONS Adjusting insulin and glucagon delivery at exercise onset within a dual-hormone AP significantly reduces hypoglycaemia compared with no adjustment and performs similarly to SAP therapy when insulin is adjusted before exercise.
Collapse
Affiliation(s)
- P G Jacobs
- Department of Biomedical Engineering, Oregon Health and Science University, Portland.
| | - J El Youssef
- Department of Medicine, Division of Endocrinology, Harold Schnitzer Diabetes Health Center, Oregon Health and Science University, Portland
| | - R Reddy
- Department of Biomedical Engineering, Oregon Health and Science University, Portland
| | - N Resalat
- Department of Biomedical Engineering, Oregon Health and Science University, Portland
| | - D Branigan
- Department of Medicine, Division of Endocrinology, Harold Schnitzer Diabetes Health Center, Oregon Health and Science University, Portland
| | - J Condon
- Department of Biomedical Engineering, Oregon Health and Science University, Portland
| | - N Preiser
- Department of Biomedical Engineering, Oregon Health and Science University, Portland
| | - K Ramsey
- Oregon Clinical and Translational Research Institute Biostatistics and Design Program, Oregon Health and Science University, Portland
| | - M Jones
- Department of Medicine, Division of Endocrinology, Harold Schnitzer Diabetes Health Center, Oregon Health and Science University, Portland
| | - C Edwards
- Department of Medicine, Division of Endocrinology, Harold Schnitzer Diabetes Health Center, Oregon Health and Science University, Portland
| | - K Kuehl
- Department of Medicine, Division of Health Promotion and Sports Medicine, Human Performance Laboratory, Oregon Health and Science University, Portland
| | - J Leitschuh
- Department of Biomedical Engineering, Oregon Health and Science University, Portland
| | - U Rajhbeharrysingh
- Department of Biomedical Engineering, Oregon Health and Science University, Portland
| | - J R Castle
- Department of Medicine, Division of Endocrinology, Harold Schnitzer Diabetes Health Center, Oregon Health and Science University, Portland
| |
Collapse
|
37
|
Blauw H, Keith-Hynes P, Koops R, DeVries JH. A Review of Safety and Design Requirements of the Artificial Pancreas. Ann Biomed Eng 2016; 44:3158-3172. [PMID: 27352278 PMCID: PMC5093196 DOI: 10.1007/s10439-016-1679-2] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Accepted: 06/13/2016] [Indexed: 01/03/2023]
Abstract
As clinical studies with artificial pancreas systems for automated blood glucose control in patients with type 1 diabetes move to unsupervised real-life settings, product development will be a focus of companies over the coming years. Directions or requirements regarding safety in the design of an artificial pancreas are, however, lacking. This review aims to provide an overview and discussion of safety and design requirements of the artificial pancreas. We performed a structured literature search based on three search components—type 1 diabetes, artificial pancreas, and safety or design—and extended the discussion with our own experiences in developing artificial pancreas systems. The main hazards of the artificial pancreas are over- and under-dosing of insulin and, in case of a bi-hormonal system, of glucagon or other hormones. For each component of an artificial pancreas and for the complete system we identified safety issues related to these hazards and proposed control measures. Prerequisites that enable the control algorithms to provide safe closed-loop control are accurate and reliable input of glucose values, assured hormone delivery and an efficient user interface. In addition, the system configuration has important implications for safety, as close cooperation and data exchange between the different components is essential.
Collapse
Affiliation(s)
- Helga Blauw
- Department of Endocrinology, Academic Medical Center, University of Amsterdam, P.O Box 22660, 1100 DD, Amsterdam, The Netherlands. .,Inreda Diabetic BV, Goor, The Netherlands.
| | - Patrick Keith-Hynes
- TypeZero Technologies, LLC, Charlottesville, VA, USA.,Center for Diabetes Technology, University of Virginia, Charlottesville, VA, USA
| | | | - J Hans DeVries
- Department of Endocrinology, Academic Medical Center, University of Amsterdam, P.O Box 22660, 1100 DD, Amsterdam, The Netherlands
| |
Collapse
|
38
|
Trevitt S, Simpson S, Wood A. Artificial Pancreas Device Systems for the Closed-Loop Control of Type 1 Diabetes: What Systems Are in Development? J Diabetes Sci Technol 2016; 10:714-23. [PMID: 26589628 PMCID: PMC5038530 DOI: 10.1177/1932296815617968] [Citation(s) in RCA: 89] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND Closed-loop artificial pancreas device (APD) systems are externally worn medical devices that are being developed to enable people with type 1 diabetes to regulate their blood glucose levels in a more automated way. The innovative concept of this emerging technology is that hands-free, continuous, glycemic control can be achieved by using digital communication technology and advanced computer algorithms. METHODS A horizon scanning review of this field was conducted using online sources of intelligence to identify systems in development. The systems were classified into subtypes according to their level of automation, the hormonal and glycemic control approaches used, and their research setting. RESULTS Eighteen closed-loop APD systems were identified. All were being tested in clinical trials prior to potential commercialization. Six were being studied in the home setting, 5 in outpatient settings, and 7 in inpatient settings. It is estimated that 2 systems may become commercially available in the EU by the end of 2016, 1 during 2017, and 2 more in 2018. CONCLUSIONS There are around 18 closed-loop APD systems progressing through early stages of clinical development. Only a few of these are currently in phase 3 trials and in settings that replicate real life.
Collapse
Affiliation(s)
- Sara Trevitt
- NIHR Horizon Scanning Research & Intelligence Centre, University of Birmingham, Birmingham, UK
| | - Sue Simpson
- NIHR Horizon Scanning Research & Intelligence Centre, University of Birmingham, Birmingham, UK
| | - Annette Wood
- NIHR Horizon Scanning Research & Intelligence Centre, University of Birmingham, Birmingham, UK
| |
Collapse
|
39
|
Ding S, Schumacher M. Sensor Monitoring of Physical Activity to Improve Glucose Management in Diabetic Patients: A Review. SENSORS 2016; 16:s16040589. [PMID: 27120602 PMCID: PMC4851102 DOI: 10.3390/s16040589] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Revised: 04/14/2016] [Accepted: 04/21/2016] [Indexed: 12/11/2022]
Abstract
Diabetic individuals need to tightly control their blood glucose concentration. Several methods have been developed for this purpose, such as the finger-prick or continuous glucose monitoring systems (CGMs). However, these methods present the disadvantage of being invasive. Moreover, CGMs have limited accuracy, notably to detect hypoglycemia. It is also known that physical exercise, and even daily activity, disrupt glucose dynamics and can generate problems with blood glucose regulation during and after exercise. In order to deal with these challenges, devices for monitoring patients’ physical activity are currently under development. This review focuses on non-invasive sensors using physiological parameters related to physical exercise that were used to improve glucose monitoring in type 1 diabetes (T1DM) patients. These devices are promising for diabetes management. Indeed they permit to estimate glucose concentration either based solely on physical activity parameters or in conjunction with CGM or non-invasive CGM (NI-CGM) systems. In these last cases, the vital signals are used to modulate glucose estimations provided by the CGM and NI-CGM devices. Finally, this review indicates possible limitations of these new biosensors and outlines directions for future technologic developments.
Collapse
Affiliation(s)
- Sandrine Ding
- HESAV, University of Applied Sciences and Arts Western Switzerland (HES-SO), Av. Beaumont 21, Lausanne 1011, Switzerland.
| | - Michael Schumacher
- Institute of Information Systems, University of Applied Sciences and Arts Western Switzerland (HES-SO), Techno-Pôle 3, Sierre 3960, Switzerland.
| |
Collapse
|
40
|
Turksoy K, Roy A, Cinar A. Real-Time Model-Based Fault Detection of Continuous Glucose Sensor Measurements. IEEE Trans Biomed Eng 2016; 64:1437-1445. [PMID: 26930674 DOI: 10.1109/tbme.2016.2535412] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE Faults in subcutaneous glucose concentration readings with a continuous glucose monitoring (CGM) may affect the computation of insulin infusion rates that can lead to hypoglycemia or hyperglycemia in artificial pancreas control systems for patients with type 1 diabetes (T1D). METHODS Multivariable statistical monitoring methods are proposed for detection of faults in glucose concentration values reported by a subcutaneous glucose sensor. A nonlinear first principle glucose/insulin/meal dynamic model is developed. An unscented Kalman filter is used for state and parameter estimation of the nonlinear model. Principal component analysis models are developed and used for detection of dynamic changes. K-nearest neighbor classification algorithm is used for diagnosis of faults. Data from 51 subjects are used to assess the performance of the algorithm. RESULTS The results indicate that the proposed algorithm works successfully with 84.2% sensitivity. Overall, 155 (out of 184) of the CGM failures are detected with a 2.8-min average detection time. CONCLUSION A novel algorithm that integrates data-driven and model-based methods is developed. The proposed method is able to detect CGM failures with a high rate of success. SIGNIFICANCE The proposed fault detection algorithm can decrease the effects of faults on insulin infusion rates and reduce the potential for hypo- or hyperglycemia for patients with T1D.
Collapse
|
41
|
Dadlani V, Levine JA, McCrady-Spitzer SK, Dassau E, Kudva YC. Physical Activity Capture Technology With Potential for Incorporation Into Closed-Loop Control for Type 1 Diabetes. J Diabetes Sci Technol 2015; 9:1208-16. [PMID: 26481641 PMCID: PMC4667300 DOI: 10.1177/1932296815609949] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Physical activity is an important determinant of glucose variability in type 1 diabetes (T1D). It has been incorporated as a nonglucose input into closed-loop control (CLC) protocols for T1D during the last 4 years mainly by 3 research groups in single center based controlled clinical trials involving a maximum of 18 subjects in any 1 study. Although physical activity data capture may have clinical benefit in patients with T1D by impacting cardiovascular fitness and optimal body weight achievement and maintenance, limited number of such studies have been conducted to date. Clinical trial registries provide information about a single small sample size 2 center prospective study incorporating physical activity data input to modulate closed-loop control in T1D that are seeking to build on prior studies. We expect an increase in such studies especially since the NIH has expanded support of this type of research with additional grants starting in the second half of 2015. Studies (1) involving patients with other disorders that have lasted 12 weeks or longer and tracked physical activity and (2) including both aerobic and resistance activity may offer insights about the user experience and device optimization even as single input CLC heads into real-world clinical trials over the next few years and nonglucose input is introduced as the next advance.
Collapse
Affiliation(s)
- Vikash Dadlani
- Endocrine Research Unit, Mayo Clinic, Rochester, MN, USA
| | - James A Levine
- Mayo Clinic, Scottsdale, AZ, USA Obesity Solutions, Mayo Clinic Arizona and Arizona State University, Tempe, AZ, USA
| | | | - Eyal Dassau
- Harvard John A. Paulson School of Engineering and Applied Sciences, Cambridge, MA, USA
| | - Yogish C Kudva
- Endocrine Research Unit, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
42
|
Turksoy K, Paulino TML, Zaharieva DP, Yavelberg L, Jamnik V, Riddell MC, Cinar A. Classification of Physical Activity: Information to Artificial Pancreas Control Systems in Real Time. J Diabetes Sci Technol 2015; 9:1200-7. [PMID: 26443291 PMCID: PMC4667299 DOI: 10.1177/1932296815609369] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Physical activity has a wide range of effects on glucose concentrations in type 1 diabetes (T1D) depending on the type (ie, aerobic, anaerobic, mixed) and duration of activity performed. This variability in glucose responses to physical activity makes the development of artificial pancreas (AP) systems challenging. Automatic detection of exercise type and intensity, and its classification as aerobic or anaerobic would provide valuable information to AP control algorithms. This can be achieved by using a multivariable AP approach where biometric variables are measured and reported to the AP at high frequency. We developed a classification system that identifies, in real time, the exercise intensity and its reliance on aerobic or anaerobic metabolism and tested this approach using clinical data collected from 5 persons with T1D and 3 individuals without T1D in a controlled laboratory setting using a variety of common types of physical activity. The classifier had an average sensitivity of 98.7% for physiological data collected over a range of exercise modalities and intensities in these subjects. The classifier will be added as a new module to the integrated multivariable adaptive AP system to enable the detection of aerobic and anaerobic exercise for enhancing the accuracy of insulin infusion strategies during and after exercise.
Collapse
Affiliation(s)
- Kamuran Turksoy
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | | | - Dessi P Zaharieva
- School of Kinesiology and Health Science & Muscle Health Research Center, York University, Toronto, Ontario, Canada
| | - Loren Yavelberg
- School of Kinesiology and Health Science & Muscle Health Research Center, York University, Toronto, Ontario, Canada
| | - Veronica Jamnik
- School of Kinesiology and Health Science & Muscle Health Research Center, York University, Toronto, Ontario, Canada
| | - Michael C Riddell
- School of Kinesiology and Health Science & Muscle Health Research Center, York University, Toronto, Ontario, Canada
| | - Ali Cinar
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| |
Collapse
|
43
|
Jacobs PG, Resalat N, El Youssef J, Reddy R, Branigan D, Preiser N, Condon J, Castle J. Incorporating an Exercise Detection, Grading, and Hormone Dosing Algorithm Into the Artificial Pancreas Using Accelerometry and Heart Rate. J Diabetes Sci Technol 2015; 9:1175-84. [PMID: 26438720 PMCID: PMC4667295 DOI: 10.1177/1932296815609371] [Citation(s) in RCA: 66] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
In this article, we present several important contributions necessary for enabling an artificial endocrine pancreas (AP) system to better respond to exercise events. First, we show how exercise can be automatically detected using body-worn accelerometer and heart rate sensors. During a 22 hour overnight inpatient study, 13 subjects with type 1 diabetes wearing a Zephyr accelerometer and heart rate monitor underwent 45 minutes of mild aerobic treadmill exercise while controlling their glucose levels using sensor-augmented pump therapy. We used the accelerometer and heart rate as inputs into a validated regression model. Using this model, we were able to detect the exercise event with a sensitivity of 97.2% and a specificity of 99.5%. Second, from this same study, we show how patients' glucose declined during the exercise event and we present results from in silico modeling that demonstrate how including an exercise model in the glucoregulatory model improves the estimation of the drop in glucose during exercise. Last, we present an exercise dosing adjustment algorithm and describe parameter tuning and performance using an in silico glucoregulatory model during an exercise event.
Collapse
Affiliation(s)
- Peter G Jacobs
- Department of Biomedical Engineering, Oregon Health and Science University, Portland OR, USA
| | - Navid Resalat
- Department of Biomedical Engineering, Oregon Health and Science University, Portland OR, USA
| | - Joseph El Youssef
- Harold Schnitzer Diabetes Health Center, Oregon Health and Science University, Portland OR, USA
| | - Ravi Reddy
- Department of Biomedical Engineering, Oregon Health and Science University, Portland OR, USA
| | - Deborah Branigan
- Harold Schnitzer Diabetes Health Center, Oregon Health and Science University, Portland OR, USA
| | - Nicholas Preiser
- Department of Biomedical Engineering, Oregon Health and Science University, Portland OR, USA
| | - John Condon
- Department of Biomedical Engineering, Oregon Health and Science University, Portland OR, USA
| | - Jessica Castle
- Harold Schnitzer Diabetes Health Center, Oregon Health and Science University, Portland OR, USA
| |
Collapse
|
44
|
Riddell MC, Zaharieva DP, Yavelberg L, Cinar A, Jamnik VK. Exercise and the Development of the Artificial Pancreas: One of the More Difficult Series of Hurdles. J Diabetes Sci Technol 2015; 9:1217-26. [PMID: 26428933 PMCID: PMC4667314 DOI: 10.1177/1932296815609370] [Citation(s) in RCA: 58] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Regular physical activity (PA) promotes numerous health benefits for people living with type 1 diabetes (T1D). However, PA also complicates blood glucose control. Factors affecting blood glucose fluctuations during PA include activity type, intensity and duration as well as the amount of insulin and food in the body at the time of the activity. To maintain equilibrium with blood glucose concentrations during PA, the rate of glucose appearance (Ra) to disappearance (Rd) in the bloodstream must be balanced. In nondiabetics, there is a rise in glucagon and a reduction in insulin release at the onset of mild to moderate aerobic PA. During intense aerobic -anaerobic work, insulin release first decreases and then rises rapidly in early recovery to offset a more dramatic increase in counterregulatory hormones and metabolites. An "exercise smart" artificial pancreas (AP) must be capable of sensing glucose and perhaps other physiological responses to various types and intensities of PA. The emergence of this new technology may benefit active persons with T1D who are prone to hypo and hyperglycemia.
Collapse
Affiliation(s)
- Michael C Riddell
- School of Kinesiology and Health Science, Faculty of Health, Physical Activity and Chronic Disease Unit, York University, Toronto, Ontario, Canada
| | - Dessi P Zaharieva
- School of Kinesiology and Health Science, Faculty of Health, Physical Activity and Chronic Disease Unit, York University, Toronto, Ontario, Canada
| | - Loren Yavelberg
- School of Kinesiology and Health Science, Faculty of Health, Physical Activity and Chronic Disease Unit, York University, Toronto, Ontario, Canada
| | - Ali Cinar
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Veronica K Jamnik
- School of Kinesiology and Health Science, Faculty of Health, Physical Activity and Chronic Disease Unit, York University, Toronto, Ontario, Canada
| |
Collapse
|
45
|
Dasanayake IS, Bevier WC, Castorino K, Pinsker JE, Seborg DE, Doyle FJ, Dassau E. Early Detection of Physical Activity for People With Type 1 Diabetes Mellitus. J Diabetes Sci Technol 2015; 9:1236-45. [PMID: 26134831 PMCID: PMC4667311 DOI: 10.1177/1932296815592409] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Early detection of exercise in individuals with type 1 diabetes mellitus (T1DM) may allow changes in therapy to prevent hypoglycemia. Currently there is limited experience with automated methods that detect the onset and end of exercise in this population. We sought to develop a novel method to quickly and reliably detect the onset and end of exercise in these individuals before significant changes in blood glucose (BG) occur. METHODS Sixteen adults with T1DM were studied as outpatients using a diary, accelerometer, heart rate monitor, and continuous glucose monitor for 2 days. These data were used to develop a principal component analysis based exercise detection method. Subjects also performed 60 and 30 minute exercise sessions at 30% and 50% predicted heart rate reserve (HRR), respectively. The detection method was applied to the exercise sessions to determine how quickly the detection of start and end of exercise occurred relative to change in BG. RESULTS Mild 30% HRR and moderate 50% HRR exercise onset was identified in 6 ± 3 and 5 ± 2 (mean ± SD) minutes, while completion was detected in 3 ± 8 and 6 ± 5 minutes, respectively. BG change from start of exercise to detection time was 1 ± 6 and -1 ± 3 mg/dL, and, from the end of exercise to detection time was 6 ± 4 and -17 ± 13 mg/dL, respectively, for the 2 exercise sessions. False positive and negative ratios were 4 ± 2% and 21 ± 22%. CONCLUSIONS The novel method for exercise detection identified the onset and end of exercise in approximately 5 minutes, with an average BG change of only -6 mg/dL.
Collapse
Affiliation(s)
- Isuru S Dasanayake
- Department of Chemical Engineering, University of California, Santa Barbara, CA, USA William Sansum Diabetes Center, Santa Barbara, CA, USA The first 2 authors contributed equally to this study
| | - Wendy C Bevier
- William Sansum Diabetes Center, Santa Barbara, CA, USA The first 2 authors contributed equally to this study
| | | | | | - Dale E Seborg
- Department of Chemical Engineering, University of California, Santa Barbara, CA, USA William Sansum Diabetes Center, Santa Barbara, CA, USA
| | - Francis J Doyle
- Department of Chemical Engineering, University of California, Santa Barbara, CA, USA William Sansum Diabetes Center, Santa Barbara, CA, USA
| | - Eyal Dassau
- Department of Chemical Engineering, University of California, Santa Barbara, CA, USA William Sansum Diabetes Center, Santa Barbara, CA, USA
| |
Collapse
|
46
|
Turksoy K, Samadi S, Feng J, Littlejohn E, Quinn L, Cinar A. Meal Detection in Patients With Type 1 Diabetes: A New Module for the Multivariable Adaptive Artificial Pancreas Control System. IEEE J Biomed Health Inform 2015; 20:47-54. [PMID: 26087510 DOI: 10.1109/jbhi.2015.2446413] [Citation(s) in RCA: 57] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A novel meal-detection algorithm is developed based on continuous glucose measurements. Bergman's minimal model is modified and used in an unscented Kalman filter for state estimations. The estimated rate of appearance of glucose is used for meal detection. Data from nine subjects are used to assess the performance of the algorithm. The results indicate that the proposed algorithm works successfully with high accuracy. The average change in glucose levels between the meals and the detection points is 16(±9.42) [mg/dl] for 61 successfully detected meals and snacks. The algorithm is developed as a new module of an integrated multivariable adaptive artificial pancreas control system. Meal detection with the proposed method is used to administer insulin boluses and prevent most of postprandial hyperglycemia without any manual meal announcements. A novel meal bolus calculation method is proposed and tested with the UVA/Padova simulator. The results indicate significant reduction in hyperglycemia.
Collapse
|
47
|
Abstract
While being physically active bestows many health benefits on individuals with type 1 diabetes, their overall blood glucose control is not enhanced without an effective balance of insulin dosing and food intake to maintain euglycemia before, during, and after exercise of all types. At present, a number of technological advances are already available to insulin users who desire to be physically active with optimal blood glucose control, although a number of limitations to those devices remain. In addition to continued improvements to existing technologies and introduction of new ones, finding ways to integrate all of the available data to optimize blood glucose control and performance during and following exercise will likely involve development of "smart" calculators, enhanced closed-loop systems that are able to use additional inputs and learn, and social aspects that allow devices to meet the needs of the users.
Collapse
Affiliation(s)
- Sheri R Colberg
- Human Movement Sciences Department, Old Dominion University, Norfolk, VA, USA
| | - Remmert Laan
- William Sansum Diabetes Center, Santa Barbara, CA, USA
| | - Eyal Dassau
- Department of Chemical Engineering, University of California, Santa Barbara, CA, USA
| | - David Kerr
- William Sansum Diabetes Center, Santa Barbara, CA, USA
| |
Collapse
|
48
|
Visentin R, Dalla Man C, Kudva YC, Basu A, Cobelli C. Circadian variability of insulin sensitivity: physiological input for in silico artificial pancreas. Diabetes Technol Ther 2015; 17:1-7. [PMID: 25531427 PMCID: PMC4290795 DOI: 10.1089/dia.2014.0192] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND Closed-loop control clinical research trials have been considerably accelerated by in silico trials using the Food and Drug Administration-accepted type 1 diabetes mellitus (T1DM) simulator. We have recently demonstrated that postprandial insulin sensitivity (SI) in T1DM subjects was lower at breakfast (B) than lunch (L) and dinner (D), but not significantly, because of the small population size. The goal of this study was therefore to incorporate this novel information into the University of Virginia/Padova T1DM simulator and to reproduce in silico the observed circadian variability. SUBJECTS AND METHODS Twenty T1DM subjects received an identical mixed meal at B, L, and D. SI was calculated for each meal using the oral glucose minimal model. Seven SI daily patterns were identified, and their probabilities were estimated. Each in silico subject was linked to a time-varying SI profile, while random deviations of up to 40% were allowed. RESULTS Simulations were compared with experimental data. The integrated area above the basal glucose curve values were 2.60 ± 0.91 (B), 1.38 ± 0.91 (L), and 1.44 ± 1.07 (D) 10(4) min · mg/dL in silico versus 2.87 ± 1.65 (B), 1.98 ± 1.56 (L), and 2.16 ± 2.00 (D) 10(4) min · mg/dL in vivo. Incremental peak glucose values were 109 ± 33 (B), 80 ± 29 (L), and 81 ± 30 (D) mg/dL in silico versus 136 ± 39 (B), 126 ± 37 (L), and 125 ± 48 (D) mg/dL in vivo. CONCLUSIONS The incorporation of a time-varying SI into the simulator makes this technology suitable for running multiple-meal scenarios, thus enabling a more robust design of artificial pancreas algorithms.
Collapse
Affiliation(s)
- Roberto Visentin
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Chiara Dalla Man
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Yogish C. Kudva
- Division of Endocrinology, Diabetes, Metabolism, and Nutrition, Department of Internal Medicine, Mayo Clinic and Foundation, Rochester, Minnesota
| | - Ananda Basu
- Division of Endocrinology, Diabetes, Metabolism, and Nutrition, Department of Internal Medicine, Mayo Clinic and Foundation, Rochester, Minnesota
| | - Claudio Cobelli
- Department of Information Engineering, University of Padova, Padova, Italy
| |
Collapse
|