1
|
Hobson MA, Hu Y, Caldwell B, Cohen GN, Glide-Hurst C, Huang L, Jackson PD, Jang S, Langner U, Lee HJ, Levesque IR, Narayanan S, Park JC, Steffen J, Wu QJ, Zhou Y. AAPM Task Group 334: A guidance document to using radiotherapy immobilization devices and accessories in an MR environment. Med Phys 2024; 51:3822-3849. [PMID: 38648857 PMCID: PMC11330642 DOI: 10.1002/mp.17061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 11/13/2023] [Accepted: 03/28/2024] [Indexed: 04/25/2024] Open
Abstract
Use of magnetic resonance (MR) imaging in radiation therapy has increased substantially in recent years as more radiotherapy centers are having MR simulators installed, requesting more time on clinical diagnostic MR systems, or even treating with combination MR linear accelerator (MR-linac) systems. With this increased use, to ensure the most accurate integration of images into radiotherapy (RT), RT immobilization devices and accessories must be able to be used safely in the MR environment and produce minimal perturbations. The determination of the safety profile and considerations often falls to the medical physicist or other support staff members who at a minimum should be a Level 2 personnel as per the ACR. The purpose of this guidance document will be to help guide the user in making determinations on MR Safety labeling (i.e., MR Safe, Conditional, or Unsafe) including standard testing, and verification of image quality, when using RT immobilization devices and accessories in an MR environment.
Collapse
Affiliation(s)
- Maritza A Hobson
- Department of Radiation Oncology, Wake Forest University School of Medicine, Winston-Salem, North Carolina, USA
| | - Yanle Hu
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA
| | - Barrett Caldwell
- School of Industrial Engineering, Purdue University, West Lafayette, Indiana, USA
- School of Aeronautics and Astronautics, Purdue University, West Lafayette, Indiana, USA
| | - Gil'ad N Cohen
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York, USA
| | - Carri Glide-Hurst
- Department of Human Oncology, University of Wisconsin--Madison, Madison, Wisconsin, USA
- Department of Medical Physics, University of Wisconsin--Madison, Madison, Wisconsin, USA
| | - Long Huang
- Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA
| | - Paul D Jackson
- Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan, USA
| | - Sunyoung Jang
- Department of Radiation Oncology, Penn State College of Medicine, Hershey, Pennsylvania, USA
| | - Ulrich Langner
- Department of Radiation Oncology, Rhode Island Hospital, Providence, Rhode Island, USA
| | - Hannah J Lee
- Corewell Health William Beaumont University Hospital, Royal Oak, Michigan, USA
| | - Ives R Levesque
- Gerald Bronfman Department of Oncology and Medical Physics Unit, McGill University, Montreal, QC, Canada
- Department of Medical Physics, McGill University Health Centre, Cedars Cancer Centre, Montreal, QC, Canada
| | - Sreeram Narayanan
- Department of Radiation Oncology, Virginia Mason Cancer Institute, Seattle, Washington, USA
| | - Justin C Park
- Division of Medical Physics, Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida, USA
| | | | - Q Jackie Wu
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA
| | - Yong Zhou
- Department of Radiology Services, Corewell Health, Grand Rapids, Michigan, USA
| |
Collapse
|
2
|
Fu H, Zhang J, Li B, Chen L, Zou J, Zhang Z, Zou H. Abdominal multi-organ segmentation in Multi-sequence MRIs based on visual attention guided network and knowledge distillation. Phys Med 2024; 122:103385. [PMID: 38810392 DOI: 10.1016/j.ejmp.2024.103385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 03/17/2024] [Accepted: 05/21/2024] [Indexed: 05/31/2024] Open
Abstract
PURPOSE The segmentation of abdominal organs in magnetic resonance imaging (MRI) plays a pivotal role in various therapeutic applications. Nevertheless, the application of deep-learning methods to abdominal organ segmentation encounters numerous challenges, especially in addressing blurred boundaries and regions characterized by low-contrast. METHODS In this study, a multi-scale visual attention-guided network (VAG-Net) was proposed for abdominal multi-organ segmentation based on unpaired multi-sequence MRI. A new visual attention-guided (VAG) mechanism was designed to enhance the extraction of contextual information, particularly at the edge of organs. Furthermore, a new loss function inspired by knowledge distillation was introduced to minimize the semantic disparity between different MRI sequences. RESULTS The proposed method was evaluated on the CHAOS 2019 Challenge dataset and compared with six state-of-the-art methods. The results demonstrated that our model outperformed these methods, achieving DSC values of 91.83 ± 0.24% and 94.09 ± 0.66% for abdominal multi-organ segmentation in T1-DUAL and T2-SPIR modality, respectively. CONCLUSION The experimental results show that our proposed method has superior performance in abdominal multi-organ segmentation, especially in the case of small organs such as the kidneys.
Collapse
Affiliation(s)
- Hao Fu
- Department of Automation, School of Information Science and Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Jian Zhang
- Department of Automation, School of Information Science and Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Bin Li
- Jiangnan University Medical Center, Wuxi No. 2 People's Hospital, Wu Xi, Jiangsu 214000, China
| | - Lanlan Chen
- Department of Automation, School of Information Science and Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Junzhong Zou
- Department of Automation, School of Information Science and Engineering, East China University of Science and Technology, Shanghai 200237, China.
| | - ZhuiYang Zhang
- Jiangnan University Medical Center, Wuxi No. 2 People's Hospital, Wu Xi, Jiangsu 214000, China.
| | - Hao Zou
- Center for Intelligent Medical Imaging and Health, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518000, China.
| |
Collapse
|
3
|
Emin S, Rossi E, Myrvold Rooth E, Dorniok T, Hedman M, Gagliardi G, Villegas F. Clinical implementation of a commercial synthetic computed tomography solution for radiotherapy treatment of glioblastoma. Phys Imaging Radiat Oncol 2024; 30:100589. [PMID: 38818305 PMCID: PMC11137592 DOI: 10.1016/j.phro.2024.100589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 05/12/2024] [Accepted: 05/13/2024] [Indexed: 06/01/2024] Open
Abstract
Background and Purpose Magnetic resonance (MR)-only radiotherapy (RT) workflow eliminates uncertainties due to computed tomography (CT)-MR image registration, by using synthetic CT (sCT) images generated from MR. This study describes the clinical implementation process, from retrospective commissioning to prospective validation stage of a commercial artificial intelligence (AI)-based sCT product. Evaluation of the dosimetric performance of the sCT is presented, with emphasis on the impact of voxel size differences between image modalities. Materials and methods sCT performance was assessed in glioblastoma RT planning. Dose differences for 30 patients in both commissioning and validation cohorts were calculated at various dose-volume-histogram (DVH) points for target and organs-at-risk (OAR). A gamma analysis was conducted on regridded image plans. Quality assurance (QA) guidelines were established based on commissioning phase results. Results Mean dose difference to target structures was found to be within ± 0.7 % regardless of image resolution and cohort. OARs' mean dose differences were within ± 1.3 % for plans calculated on regridded images for both cohorts, while differences were higher for plans with original voxel size, reaching up to -4.2 % for chiasma D2% in the commissioning cohort. Gamma passing rates for the brain structure using the criteria 1 %/1mm, 2 %/2mm and 3 %/3mm were 93.6 %/99.8 %/100 % and 96.6 %/99.9 %/100 % for commissioning and validation cohorts, respectively. Conclusions Dosimetric outcomes in both commissioning and validation stages confirmed sCT's equivalence to CT. The large patient cohort in this study aided in establishing a robust QA program for the MR-only workflow, now applied in glioblastoma RT at our center.
Collapse
Affiliation(s)
- Sevgi Emin
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, 171 76 Stockholm, Sweden
| | - Elia Rossi
- Department of Radiation Oncology, Karolinska University Hospital, 171 76 Stockholm, Sweden
| | | | - Torsten Dorniok
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, 171 76 Stockholm, Sweden
| | - Mattias Hedman
- Department of Radiation Oncology, Karolinska University Hospital, 171 76 Stockholm, Sweden
- Department of Oncology-Pathology, Karolinska Institute, 171 77 Stockholm, Sweden
| | - Giovanna Gagliardi
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, 171 76 Stockholm, Sweden
- Department of Oncology-Pathology, Karolinska Institute, 171 77 Stockholm, Sweden
| | - Fernanda Villegas
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, 171 76 Stockholm, Sweden
- Department of Oncology-Pathology, Karolinska Institute, 171 77 Stockholm, Sweden
| |
Collapse
|
4
|
García-Figueiras R, Baleato-González S, Luna A, Padhani AR, Vilanova JC, Carballo-Castro AM, Oleaga-Zufiria L, Vallejo-Casas JA, Marhuenda A, Gómez-Caamaño A. How Imaging Advances Are Defining the Future of Precision Radiation Therapy. Radiographics 2024; 44:e230152. [PMID: 38206833 DOI: 10.1148/rg.230152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2024]
Abstract
Radiation therapy is fundamental in the treatment of cancer. Imaging has always played a central role in radiation oncology. Integrating imaging technology into irradiation devices has increased the precision and accuracy of dose delivery and decreased the toxic effects of the treatment. Although CT has become the standard imaging modality in radiation therapy, the development of recently introduced next-generation imaging techniques has improved diagnostic and therapeutic decision making in radiation oncology. Functional and molecular imaging techniques, as well as other advanced imaging modalities such as SPECT, yield information about the anatomic and biologic characteristics of tumors for the radiation therapy workflow. In clinical practice, they can be useful for characterizing tumor phenotypes, delineating volumes, planning treatment, determining patients' prognoses, predicting toxic effects, assessing responses to therapy, and detecting tumor relapse. Next-generation imaging can enable personalization of radiation therapy based on a greater understanding of tumor biologic factors. It can be used to map tumor characteristics, such as metabolic pathways, vascularity, cellular proliferation, and hypoxia, that are known to define tumor phenotype. It can also be used to consider tumor heterogeneity by highlighting areas at risk for radiation resistance for focused biologic dose escalation, which can impact the radiation planning process and patient outcomes. The authors review the possible contributions of next-generation imaging to the treatment of patients undergoing radiation therapy. In addition, the possible roles of radio(geno)mics in radiation therapy, the limitations of these techniques, and hurdles in introducing them into clinical practice are discussed. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material.
Collapse
Affiliation(s)
- Roberto García-Figueiras
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Sandra Baleato-González
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Antonio Luna
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Anwar R Padhani
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Joan C Vilanova
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Ana M Carballo-Castro
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Laura Oleaga-Zufiria
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Juan Antonio Vallejo-Casas
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Ana Marhuenda
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Antonio Gómez-Caamaño
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| |
Collapse
|
5
|
McDonald BA, Dal Bello R, Fuller CD, Balermpas P. The Use of MR-Guided Radiation Therapy for Head and Neck Cancer and Recommended Reporting Guidance. Semin Radiat Oncol 2024; 34:69-83. [PMID: 38105096 DOI: 10.1016/j.semradonc.2023.10.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
Although magnetic resonance imaging (MRI) has become standard diagnostic workup for head and neck malignancies and is currently recommended by most radiological societies for pharyngeal and oral carcinomas, its utilization in radiotherapy has been heterogeneous during the last decades. However, few would argue that implementing MRI for annotation of target volumes and organs at risk provides several advantages, so that implementation of the modality for this purpose is widely accepted. Today, the term MR-guidance has received a much broader meaning, including MRI for adaptive treatments, MR-gating and tracking during radiotherapy application, MR-features as biomarkers and finally MR-only workflows. First studies on treatment of head and neck cancer on commercially available dedicated hybrid-platforms (MR-linacs), with distinct common features but also differences amongst them, have also been recently reported, as well as "biological adaptation" based on evaluation of early treatment response via functional MRI-sequences such as diffusion weighted ones. Yet, all of these approaches towards head and neck treatment remain at their infancy, especially when compared to other radiotherapy indications. Moreover, the lack of standardization for reporting MR-guided radiotherapy is a major obstacle both to further progress in the field and to conduct and compare clinical trials. Goals of this article is to present and explain all different aspects of MR-guidance for radiotherapy of head and neck cancer, summarize evidence, as well as possible advantages and challenges of the method and finally provide a comprehensive reporting guidance for use in clinical routine and trials.
Collapse
Affiliation(s)
- Brigid A McDonald
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Riccardo Dal Bello
- Department of Radiation Oncology, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Clifton D Fuller
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Panagiotis Balermpas
- Department of Radiation Oncology, University Hospital Zurich and University of Zurich, Zurich, Switzerland.
| |
Collapse
|
6
|
Kraft J, Lutyj P, Grabenbauer F, Ströhle SP, Tamihardja J, Razinskas G, Weick S, Richter A, Huflage H, Wittig A, Flentje M, Lisowski D. Assessment of dual-energy computed tomography derived virtual monoenergetic imaging for target volume delineation of brain metastases. Radiother Oncol 2023; 187:109840. [PMID: 37536377 DOI: 10.1016/j.radonc.2023.109840] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 07/21/2023] [Accepted: 07/24/2023] [Indexed: 08/05/2023]
Abstract
BACKGROUND Objective and subjective assessment of image quality of brain metastases on dual-energy computed tomography (DECT) virtual monoenergetic imaging (VMI) and its impact on target volume delineation. MATERIALS AND METHODS 26 patients with 37 brain metastases receiving Magnetic Resonance Imaging (MRI) and DECT for stereotactic radiotherapy planning were included in this retrospective analysis. Lesion contrast (LC), contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were assessed for reconstructed VMI at 63 keV and artificial 120 kV Computed Tomography (CT). Image contrast and demarcation of metastases between 120 kV CT, VMI and MRI were subjectively assessed. Brain metastases were delineated by four radiation oncologists on VMI with a fixed or free brain window and contours were compared to solely MRI-based delineation using the Dice similarity coefficient. RESULTS LC, CNR and SNR were significantly higher in VMI than in 120 kV CT (p < 0.0001). Image contrast and lesion demarcation were significantly better on VMI compared to 120 kV CT (p < 0.0001). Mean gross tumor volume (GTV)/planning target volume (PTV) Dice similarity coefficients were 0.87/0.9 for metastases without imaging uncertainties (no artifacts, calcification or impaired visibility with MRI) but worse for metastases with imaging uncertainties (0.71/0.74). Target volumes delineated on VMI were around 5-10% smaller compared to MRI. CONCLUSION Image quality of VMI is objectively and subjectively superior to conventional CT. VMI provides significant advantages in stereotactic radiotherapy planning with improved visibility of brain metastases and geometrically distortion-free representation of brain metastases. Beside a plausibility check of MRI-based target volume delineation, VMI might improve reliability and accuracy in target volume definition particularly in cases with imaging uncertainties with MRI.
Collapse
Affiliation(s)
- Johannes Kraft
- Department of Radiation Oncology, University Hospital Wuerzburg, Wuerzburg, Germany.
| | - Paul Lutyj
- Department of Radiation Oncology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Felix Grabenbauer
- Department of Radiation Oncology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Serge-Peer Ströhle
- Department of Radiation Oncology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Jörg Tamihardja
- Department of Radiation Oncology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Gary Razinskas
- Department of Radiation Oncology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Stefan Weick
- Department of Radiation Oncology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Anne Richter
- Department of Radiation Oncology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Henner Huflage
- Department of Diagnostic and Interventional Radiology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Andrea Wittig
- Department of Radiation Oncology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Michael Flentje
- Department of Radiation Oncology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Dominik Lisowski
- Department of Radiation Oncology, University Hospital Wuerzburg, Wuerzburg, Germany
| |
Collapse
|
7
|
Sohn JJ, Lim S, Das IJ, Yadav P. An integrated and fast imaging quality assurance phantom for a 0.35 T magnetic resonance imaging linear accelerator. Phys Imaging Radiat Oncol 2023; 27:100462. [PMID: 37449023 PMCID: PMC10338140 DOI: 10.1016/j.phro.2023.100462] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 06/17/2023] [Accepted: 06/20/2023] [Indexed: 07/18/2023] Open
Abstract
Purpose Periodic imaging quality assurance (QA) of magnetic resonance imaging linear accelerator (MRL) is critical. The feasibility of a new MRL imaging phantom used for QA in the low field was evaluated with automated image analysis of various parameters for accuracy and reproducibility. Methods and materials The new MRL imaging phantom was scanned across every 30 degrees of the gantry, having the on/off state of the linac in a low-field MRL system using three magnetic resonance imaging sequences: true fast imaging with steady-state precession (TrueFISP), T1 weighted (T1W), and T2 weighted (T2W). The DICOM files were used to calculate the imaging parameters: geometric distortion, uniformity, resolution, signal-to-noise ratio (SNR), and laser alignment. The point spread function (PSF) and edge spread function (ESF) were also calculated for resolution analysis. Results The phantom data showed a small standard deviation - and high consistency for each imaging parameter. The highest variability in data was observed with the true fast imaging sequence at the calibration angle, which was expected because of low resolution and short scan time (25 sec). The mean magnitude of the largest distortion measured within 200 mm diameter with TrueFISP was 0.31 ± 0.05 mm. The PSF, ESF, signal uniformity, and SNR measurements remained consistent. Laser alignment traditional offsets and angular deviation remained consistent. Conclusions The new MRL imaging phantom is reliable, reproducible, time effective, and easy to use for a 0.35 T MRL system. The results promise a more streamlined, time-saving, and error-free QA process for low-field MRL adapted in our clinical setting.
Collapse
Affiliation(s)
| | | | | | - Poonam Yadav
- Corresponding author at: Department of Radiation Oncology, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA.
| |
Collapse
|
8
|
He M, Cao Y, Chi C, Yang X, Ramin R, Wang S, Yang G, Mukhtorov O, Zhang L, Kazantsev A, Enikeev M, Hu K. Research progress on deep learning in magnetic resonance imaging-based diagnosis and treatment of prostate cancer: a review on the current status and perspectives. Front Oncol 2023; 13:1189370. [PMID: 37546423 PMCID: PMC10400334 DOI: 10.3389/fonc.2023.1189370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Accepted: 05/30/2023] [Indexed: 08/08/2023] Open
Abstract
Multiparametric magnetic resonance imaging (mpMRI) has emerged as a first-line screening and diagnostic tool for prostate cancer, aiding in treatment selection and noninvasive radiotherapy guidance. However, the manual interpretation of MRI data is challenging and time-consuming, which may impact sensitivity and specificity. With recent technological advances, artificial intelligence (AI) in the form of computer-aided diagnosis (CAD) based on MRI data has been applied to prostate cancer diagnosis and treatment. Among AI techniques, deep learning involving convolutional neural networks contributes to detection, segmentation, scoring, grading, and prognostic evaluation of prostate cancer. CAD systems have automatic operation, rapid processing, and accuracy, incorporating multiple sequences of multiparametric MRI data of the prostate gland into the deep learning model. Thus, they have become a research direction of great interest, especially in smart healthcare. This review highlights the current progress of deep learning technology in MRI-based diagnosis and treatment of prostate cancer. The key elements of deep learning-based MRI image processing in CAD systems and radiotherapy of prostate cancer are briefly described, making it understandable not only for radiologists but also for general physicians without specialized imaging interpretation training. Deep learning technology enables lesion identification, detection, and segmentation, grading and scoring of prostate cancer, and prediction of postoperative recurrence and prognostic outcomes. The diagnostic accuracy of deep learning can be improved by optimizing models and algorithms, expanding medical database resources, and combining multi-omics data and comprehensive analysis of various morphological data. Deep learning has the potential to become the key diagnostic method in prostate cancer diagnosis and treatment in the future.
Collapse
Affiliation(s)
- Mingze He
- Institute for Urology and Reproductive Health, I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Yu Cao
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Changliang Chi
- Department of Urology, The First Hospital of Jilin University (Lequn Branch), Changchun, Jilin, China
| | - Xinyi Yang
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Rzayev Ramin
- Department of Radiology, The Second University Clinic, I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Shuowen Wang
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Guodong Yang
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Otabek Mukhtorov
- Regional State Budgetary Health Care Institution, Kostroma Regional Clinical Hospital named after Korolev E.I. Avenue Mira, Kostroma, Russia
| | - Liqun Zhang
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian, Liaoning, China
| | - Anton Kazantsev
- Regional State Budgetary Health Care Institution, Kostroma Regional Clinical Hospital named after Korolev E.I. Avenue Mira, Kostroma, Russia
| | - Mikhail Enikeev
- Institute for Urology and Reproductive Health, I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Kebang Hu
- Department of Urology, The First Hospital of Jilin University (Lequn Branch), Changchun, Jilin, China
| |
Collapse
|
9
|
Stanzione A, Ponsiglione A, Alessandrino F, Brembilla G, Imbriaco M. Beyond diagnosis: is there a role for radiomics in prostate cancer management? Eur Radiol Exp 2023; 7:13. [PMID: 36907973 PMCID: PMC10008761 DOI: 10.1186/s41747-023-00321-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Accepted: 01/05/2023] [Indexed: 03/13/2023] Open
Abstract
The role of imaging in pretreatment staging and management of prostate cancer (PCa) is constantly evolving. In the last decade, there has been an ever-growing interest in radiomics as an image analysis approach able to extract objective quantitative features that are missed by human eye. However, most of PCa radiomics studies have been focused on cancer detection and characterisation. With this narrative review we aimed to provide a synopsis of the recently proposed potential applications of radiomics for PCa with a management-based approach, focusing on primary treatments with curative intent and active surveillance as well as highlighting on recurrent disease after primary treatment. Current evidence is encouraging, with radiomics and artificial intelligence appearing as feasible tools to aid physicians in planning PCa management. However, the lack of external independent datasets for validation and prospectively designed studies casts a shadow on the reliability and generalisability of radiomics models, delaying their translation into clinical practice.Key points• Artificial intelligence solutions have been proposed to streamline prostate cancer radiotherapy planning.• Radiomics models could improve risk assessment for radical prostatectomy patient selection.• Delta-radiomics appears promising for the management of patients under active surveillance.• Radiomics might outperform current nomograms for prostate cancer recurrence risk assessment.• Reproducibility of results, methodological and ethical issues must still be faced before clinical implementation.
Collapse
Affiliation(s)
- Arnaldo Stanzione
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
| | - Andrea Ponsiglione
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy.
| | | | - Giorgio Brembilla
- Department of Radiology, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Massimo Imbriaco
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
| |
Collapse
|
10
|
Nousiainen K, Santurio GV, Lundahl N, Cronholm R, Siversson C, Edmund JM. Evaluation of MRI-only based online adaptive radiotherapy of abdominal region on MR-linac. J Appl Clin Med Phys 2023; 24:e13838. [PMID: 36347050 PMCID: PMC10018672 DOI: 10.1002/acm2.13838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 09/30/2022] [Accepted: 10/18/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE A hybrid magnetic resonance linear accelerator (MRL) can perform magnetic resonance imaging (MRI) with high soft-tissue contrast to be used for online adaptive radiotherapy (oART). To obtain electron densities needed for the oART dose calculation, a computed tomography (CT) is often deformably registered to MRI. Our aim was to evaluate an MRI-only based synthetic CT (sCT) generation as an alternative to the deformed CT (dCT)-based oART in the abdominal region. METHODS The study data consisted of 57 patients who were treated on a 0.35 T MRL system mainly for abdominal tumors. Simulation MRI-CT pairs of 43 patients were used for training and validation of a prototype convolutional neural network sCT-generation algorithm, based on HighRes3DNet, for the abdominal region. For remaining test patients, sCT images were produced from simulation MRIs and daily MRIs. The dCT-based plans were re-calculated on sCT with identical calculation parameters. The sCT and dCT were compared in terms of geometric agreement and calculated dose. RESULTS The mean and one standard deviation of the geometric agreement metrics over dCT-sCT-pairs were: mean error of 8 ± 10 HU, mean absolute error of 49 ± 10 HU, and Dice similarity coefficient of 55 ± 12%, 60 ± 5%, and 82 ± 15% for bone, fat, and lung tissues, respectively. The dose differences between the sCT and dCT-based dose for planning target volumes were 0.5 ± 0.9%, 0.6 ± 0.8%, and 0.5 ± 0.8% at D2% , D50% , and D98% in physical dose and 0.8 ± 1.4%, 0.8 ± 1.2%, and 0.6 ± 1.1% in biologically effective dose (BED). For organs-at-risk, the dose differences of all evaluated dose-volume histogram points were within [-4.5%, 7.8%] and [-1.1 Gy, 3.5 Gy] in both physical dose and BED. CONCLUSIONS The geometric agreement metrics were within typically reported values and most average relative dose differences were within 1%. Thus, an MRI-only sCT-based approach is a promising alternative to the current clinical practice of the abdominal oART on MRL.
Collapse
Affiliation(s)
- Katri Nousiainen
- Department of Physics, University of Helsinki, Helsinki, Finland.,HUS Cancer Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.,HUS Medical Imaging Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| | - Grichar Valdes Santurio
- Department of Oncology, Radiotherapy Research Unit, Herlev and Gentofte Hospital, Copenhagen University, Herlev, Denmark
| | | | | | | | - Jens M Edmund
- Department of Oncology, Radiotherapy Research Unit, Herlev and Gentofte Hospital, Copenhagen University, Herlev, Denmark.,Nils Bohr Institute, Copenhagen University, Copenhagen, Denmark
| |
Collapse
|
11
|
Olberg S, Choi BS, Park I, Liang X, Kim JS, Deng J, Yan Y, Jiang S, Park JC. Ensemble learning and personalized training for the improvement of unsupervised deep learning-based synthetic CT reconstruction. Med Phys 2023; 50:1436-1449. [PMID: 36336718 DOI: 10.1002/mp.16087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 08/22/2022] [Accepted: 10/19/2022] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND The growing adoption of magnetic resonance imaging (MRI)-guided radiation therapy (RT) platforms and a focus on MRI-only RT workflows have brought the technical challenge of synthetic computed tomography (sCT) reconstruction to the forefront. Unpaired-data deep learning-based approaches to the problem offer the attractive characteristic of not requiring paired training data, but the gap between paired- and unpaired-data results can be limiting. PURPOSE We present two distinct approaches aimed at improving unpaired-data sCT reconstruction results: a cascade ensemble that combines multiple models and a personalized training strategy originally designed for the paired-data setting. METHODS Comparisons are made between the following models: (1) the paired-data fully convolutional DenseNet (FCDN), (2) the FCDN with the Intentional Deep Overfit Learning (IDOL) personalized training strategy, (3) the unpaired-data CycleGAN, (4) the CycleGAN with the IDOL training strategy, and (5) the CycleGAN as an intermediate model in a cascade ensemble approach. Evaluation of the various models over 25 total patients is carried out using a five-fold cross-validation scheme, with the patient-specific IDOL models being trained for the five patients of fold 3, chosen at random. RESULTS In both the paired- and unpaired-data settings, adopting the IDOL training strategy led to improvements in the mean absolute error (MAE) between true CT images and sCT outputs within the body contour (mean improvement, paired- and unpaired-data approaches, respectively: 38%, 9%) and in regions of bone (52%, 5%), the peak signal-to-noise ratio (PSNR; 15%, 7%), and the structural similarity index (SSIM; 6%, <1%). The ensemble approach offered additional benefits over the IDOL approach in all three metrics (mean improvement over unpaired-data approach in fold 3; MAE: 20%; bone MAE: 16%; PSNR: 10%; SSIM: 2%), and differences in body MAE between the ensemble approach and the paired-data approach are statistically insignificant. CONCLUSIONS We have demonstrated that both a cascade ensemble approach and a personalized training strategy designed initially for the paired-data setting offer significant improvements in image quality metrics for the unpaired-data sCT reconstruction task. Closing the gap between paired- and unpaired-data approaches is a step toward fully enabling these powerful and attractive unpaired-data frameworks.
Collapse
Affiliation(s)
- Sven Olberg
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Byong Su Choi
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Medical Physics and Biomedical Engineering Lab (MPBEL), Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Inkyung Park
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Medical Physics and Biomedical Engineering Lab (MPBEL), Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Xiao Liang
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Jin Sung Kim
- Medical Physics and Biomedical Engineering Lab (MPBEL), Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
- Oncosoft Inc., Seoul, South Korea
| | - Jie Deng
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Yulong Yan
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Steve Jiang
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Justin C Park
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Medical Physics and Biomedical Engineering Lab (MPBEL), Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida, USA
| |
Collapse
|
12
|
Moore-Palhares D, Ho L, Lu L, Chugh B, Vesprini D, Karam I, Soliman H, Symons S, Leung E, Loblaw A, Myrehaug S, Stanisz G, Sahgal A, Czarnota GJ. Clinical implementation of magnetic resonance imaging simulation for radiation oncology planning: 5 year experience. Radiat Oncol 2023; 18:27. [PMID: 36750891 PMCID: PMC9903411 DOI: 10.1186/s13014-023-02209-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Accepted: 01/16/2023] [Indexed: 02/09/2023] Open
Abstract
PURPOSE Integrating magnetic resonance (MR) into radiotherapy planning has several advantages. This report details the clinical implementation of an MR simulation (MR-planning) program for external beam radiotherapy (EBRT) in one of North America's largest radiotherapy programs. METHODS AND MATERIALS An MR radiotherapy planning program was developed and implemented at Sunnybrook Health Sciences Center in 2016 with two dedicated wide-bore MR platforms (1.5 and 3.0 Tesla). Planning MR was sequentially implemented every 3 months for separate treatment sites, including the central nervous system (CNS), gynecologic (GYN), head and neck (HN), genitourinary (GU), gastrointestinal (GI), breast, and brachial plexus. Essential protocols and processes were detailed in this report, including clinical workflow, optimized MR-image acquisition protocols, MR-adapted patient setup, strategies to overcome risks and challenges, and an MR-planning quality assurance program. This study retrospectively reviewed simulation site data for all MR-planning sessions performed for EBRT over the past 5 years. RESULTS From July 2016 to December 2021, 8798 MR-planning sessions were carried out, which corresponds to 25% of all computer tomography (CT) simulations (CT-planning) performed during the same period at our institution. There was a progressive rise from 80 MR-planning sessions in 2016 to 1126 in 2017, 1492 in 2018, 1824 in 2019, 2040 in 2020, and 2236 in 2021. As a result, the relative number of planning MR/CT increased from 3% of all planning sessions in 2016 to 36% in 2021. The most common site of MR-planning was CNS (49%), HN (13%), GYN (12%), GU (12%), and others (8%). CONCLUSION Detailed clinical processes and protocols of our MR-planning program were presented, which have been improved over more than 5 years of robust experience. Strategies to overcome risks and challenges in the implementation process are highlighted. Our work provides details that can be used by institutions interested in implementing an MR-planning program.
Collapse
Affiliation(s)
- Daniel Moore-Palhares
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada ,grid.17063.330000 0001 2157 2938Physical Sciences, Sunnybrook Research Institute, Toronto, Canada
| | - Ling Ho
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada
| | - Lin Lu
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada
| | - Brige Chugh
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada ,grid.17063.330000 0001 2157 2938Physical Sciences, Sunnybrook Research Institute, Toronto, Canada
| | - Danny Vesprini
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Irene Karam
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Hany Soliman
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Sean Symons
- grid.17063.330000 0001 2157 2938Physical Sciences, Sunnybrook Research Institute, Toronto, Canada ,grid.413104.30000 0000 9743 1587Department of Medical Imaging, Sunnybrook Health Sciences Centre, Toronto, Canada
| | - Eric Leung
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Andrew Loblaw
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Sten Myrehaug
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Greg Stanisz
- grid.17063.330000 0001 2157 2938Physical Sciences, Sunnybrook Research Institute, Toronto, Canada
| | - Arjun Sahgal
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Gregory J. Czarnota
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada ,grid.17063.330000 0001 2157 2938Physical Sciences, Sunnybrook Research Institute, Toronto, Canada ,grid.17063.330000 0001 2157 2938Department of Medical Biophysics, University of Toronto, Toronto, Canada
| |
Collapse
|
13
|
Ng J, Gregucci F, Pennell RT, Nagar H, Golden EB, Knisely JPS, Sanfilippo NJ, Formenti SC. MRI-LINAC: A transformative technology in radiation oncology. Front Oncol 2023; 13:1117874. [PMID: 36776309 PMCID: PMC9911688 DOI: 10.3389/fonc.2023.1117874] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 01/16/2023] [Indexed: 01/28/2023] Open
Abstract
Advances in radiotherapy technologies have enabled more precise target guidance, improved treatment verification, and greater control and versatility in radiation delivery. Amongst the recent novel technologies, Magnetic Resonance Imaging (MRI) guided radiotherapy (MRgRT) may hold the greatest potential to improve the therapeutic gains of image-guided delivery of radiation dose. The ability of the MRI linear accelerator (LINAC) to image tumors and organs with on-table MRI, to manage organ motion and dose delivery in real-time, and to adapt the radiotherapy plan on the day of treatment while the patient is on the table are major advances relative to current conventional radiation treatments. These advanced techniques demand efficient coordination and communication between members of the treatment team. MRgRT could fundamentally transform the radiotherapy delivery process within radiation oncology centers through the reorganization of the patient and treatment team workflow process. However, the MRgRT technology currently is limited by accessibility due to the cost of capital investment and the time and personnel allocation needed for each fractional treatment and the unclear clinical benefit compared to conventional radiotherapy platforms. As the technology evolves and becomes more widely available, we present the case that MRgRT has the potential to become a widely utilized treatment platform and transform the radiation oncology treatment process just as earlier disruptive radiation therapy technologies have done.
Collapse
Affiliation(s)
- John Ng
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States,*Correspondence: John Ng,
| | - Fabiana Gregucci
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States,Department of Radiation Oncology, Miulli General Regional Hospital, Acquaviva delle Fonti, Bari, Italy
| | - Ryan T. Pennell
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States
| | - Himanshu Nagar
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States
| | - Encouse B. Golden
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States
| | | | | | - Silvia C. Formenti
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States
| |
Collapse
|
14
|
Zaki P, Chuong MD, Schaub SK, Lo SS, Ibrahim M, Apisarnthanarax S. Proton Beam Therapy and Photon-Based Magnetic Resonance Image-Guided Radiation Therapy: The Next Frontiers of Radiation Therapy for Hepatocellular Carcinoma. Technol Cancer Res Treat 2023; 22:15330338231206335. [PMID: 37908130 PMCID: PMC10621304 DOI: 10.1177/15330338231206335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 08/21/2023] [Accepted: 09/21/2023] [Indexed: 11/02/2023] Open
Abstract
External beam radiation therapy (EBRT) has increasingly been utilized in the treatment of hepatocellular carcinoma (HCC) due to technological advances with positive clinical outcomes. Innovations in EBRT include improved image guidance, motion management, treatment planning, and highly conformal techniques such as intensity-modulated radiation therapy (IMRT) and stereotactic body radiation therapy (SBRT). Moreover, proton beam therapy (PBT) and magnetic resonance image-guided radiation therapy (MRgRT) have expanded the capabilities of EBRT. PBT offers the advantage of minimizing low- and moderate-dose radiation to the surrounding normal tissue, thereby preserving uninvolved liver and allowing for dose escalation. MRgRT provides the advantage of improved soft tissue delineation compared to computerized tomography (CT) guidance. Additionally, MRgRT with online adaptive therapy is particularly useful for addressing motion not otherwise managed and reducing high-dose radiation to the normal tissue such as the stomach and bowel. PBT and online adaptive MRgRT are emerging technological advancements in EBRT that may provide a significant clinical benefit for patients with HCC.
Collapse
Affiliation(s)
- Peter Zaki
- Department of Radiation Oncology, University of Washington, Seattle, WA, USA
| | - Michael D. Chuong
- Department of Radiation Oncology, Miami Cancer Institute, Miami, FL, USA
| | - Stephanie K. Schaub
- Department of Radiation Oncology, University of Washington, Seattle, WA, USA
| | - Simon S. Lo
- Department of Radiation Oncology, University of Washington, Seattle, WA, USA
| | - Mariam Ibrahim
- School of Medicine, St. George's University, St. George's, Grenada
| | | |
Collapse
|
15
|
Goodburn RJ, Philippens MEP, Lefebvre TL, Khalifa A, Bruijnen T, Freedman JN, Waddington DEJ, Younus E, Aliotta E, Meliadò G, Stanescu T, Bano W, Fatemi‐Ardekani A, Wetscherek A, Oelfke U, van den Berg N, Mason RP, van Houdt PJ, Balter JM, Gurney‐Champion OJ. The future of MRI in radiation therapy: Challenges and opportunities for the MR community. Magn Reson Med 2022; 88:2592-2608. [PMID: 36128894 PMCID: PMC9529952 DOI: 10.1002/mrm.29450] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 08/17/2022] [Accepted: 08/22/2022] [Indexed: 01/11/2023]
Abstract
Radiation therapy is a major component of cancer treatment pathways worldwide. The main aim of this treatment is to achieve tumor control through the delivery of ionizing radiation while preserving healthy tissues for minimal radiation toxicity. Because radiation therapy relies on accurate localization of the target and surrounding tissues, imaging plays a crucial role throughout the treatment chain. In the treatment planning phase, radiological images are essential for defining target volumes and organs-at-risk, as well as providing elemental composition (e.g., electron density) information for radiation dose calculations. At treatment, onboard imaging informs patient setup and could be used to guide radiation dose placement for sites affected by motion. Imaging is also an important tool for treatment response assessment and treatment plan adaptation. MRI, with its excellent soft tissue contrast and capacity to probe functional tissue properties, holds great untapped potential for transforming treatment paradigms in radiation therapy. The MR in Radiation Therapy ISMRM Study Group was established to provide a forum within the MR community to discuss the unmet needs and fuel opportunities for further advancement of MRI for radiation therapy applications. During the summer of 2021, the study group organized its first virtual workshop, attended by a diverse international group of clinicians, scientists, and clinical physicists, to explore our predictions for the future of MRI in radiation therapy for the next 25 years. This article reviews the main findings from the event and considers the opportunities and challenges of reaching our vision for the future in this expanding field.
Collapse
Affiliation(s)
- Rosie J. Goodburn
- Joint Department of PhysicsInstitute of Cancer Research and Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | | | - Thierry L. Lefebvre
- Department of PhysicsUniversity of CambridgeCambridgeUnited Kingdom
- Cancer Research UK Cambridge Research InstituteUniversity of CambridgeCambridgeUnited Kingdom
| | - Aly Khalifa
- Department of Medical BiophysicsUniversity of TorontoTorontoOntarioCanada
| | - Tom Bruijnen
- Department of RadiotherapyUniversity Medical Center UtrechtUtrechtNetherlands
| | | | - David E. J. Waddington
- Faculty of Medicine and Health, Sydney School of Health Sciences, ACRF Image X InstituteThe University of SydneySydneyNew South WalesAustralia
| | - Eyesha Younus
- Department of Medical Physics, Odette Cancer CentreSunnybrook Health Sciences CentreTorontoOntarioCanada
| | - Eric Aliotta
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Gabriele Meliadò
- Unità Operativa Complessa di Fisica SanitariaAzienda Ospedaliera Universitaria Integrata VeronaVeronaItaly
| | - Teo Stanescu
- Department of Radiation Oncology, University of Toronto and Medical Physics, Princess Margaret Cancer CentreUniversity Health NetworkTorontoOntarioCanada
| | - Wajiha Bano
- Joint Department of PhysicsInstitute of Cancer Research and Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Ali Fatemi‐Ardekani
- Department of PhysicsJackson State University (JSU)JacksonMississippiUSA
- SpinTecxJacksonMississippiUSA
- Department of Radiation OncologyCommunity Health Systems (CHS) Cancer NetworkJacksonMississippiUSA
| | - Andreas Wetscherek
- Joint Department of PhysicsInstitute of Cancer Research and Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Uwe Oelfke
- Joint Department of PhysicsInstitute of Cancer Research and Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Nico van den Berg
- Department of RadiotherapyUniversity Medical Center UtrechtUtrechtNetherlands
| | - Ralph P. Mason
- Department of RadiologyUniversity of Texas Southwestern Medical CenterDallasTexasUSA
| | - Petra J. van Houdt
- Department of Radiation OncologyNetherlands Cancer InstituteAmsterdamNetherlands
| | - James M. Balter
- Department of Radiation OncologyUniversity of MichiganAnn ArborMichiganUSA
| | - Oliver J. Gurney‐Champion
- Imaging and Biomarkers, Cancer Center Amsterdam, Amsterdam UMCUniversity of AmsterdamAmsterdamNetherlands
| |
Collapse
|
16
|
Brynolfsson P, Lerner M, Sundgren PC, Jamtheim Gustafsson C, Nilsson M, Szczepankiewicz F, Olsson LE. Tensor-valued diffusion magnetic resonance imaging in a radiotherapy setting. Phys Imaging Radiat Oncol 2022; 24:144-151. [DOI: 10.1016/j.phro.2022.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 11/02/2022] [Accepted: 11/03/2022] [Indexed: 11/11/2022] Open
|
17
|
Emergence of MR-Linac in Radiation Oncology: Successes and Challenges of Riding on the MRgRT Bandwagon. J Clin Med 2022; 11:jcm11175136. [PMID: 36079065 PMCID: PMC9456673 DOI: 10.3390/jcm11175136] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 08/26/2022] [Accepted: 08/29/2022] [Indexed: 12/05/2022] Open
Abstract
The special issue of JCM on “Advances of MRI in Radiation Oncology” provides a unique forum for scientific literature related to MR imaging in radiation oncology. This issue covered many aspects, such as MR technology, motion management, economics, soft-tissue–air interface issues, and disease sites such as the pancreas, spine, sarcoma, prostate, head and neck, and rectum from both camps—the Unity and MRIdian systems. This paper provides additional information on the success and challenges of the two systems. A challenging aspect of this technology is low throughput and the monumental task of education and training that hinders its use for the majority of therapy centers. Additionally, the cost of this technology is too high for most institutions, and hence widespread use is still limited. This article highlights some of the difficulties and how to resolve them.
Collapse
|
18
|
Nie X, Li G. Real-Time 2D MR Cine From Beam Eye's View With Tumor-Volume Projection to Ensure Beam-to-Tumor Conformality for MR-Guided Radiotherapy of Lung Cancer. Front Oncol 2022; 12:898771. [PMID: 35847879 PMCID: PMC9277147 DOI: 10.3389/fonc.2022.898771] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Accepted: 05/20/2022] [Indexed: 12/02/2022] Open
Abstract
Purpose To minimize computation latency using a predictive strategy to retrieve and project tumor volume onto 2D MR beam eye’s view (BEV) cine from time-resolved four-dimensional magnetic resonance imaging (TR-4DMRI) libraries (inhalation/exhalation) for personalized MR-guided intensity-modulated radiotherapy (IMRT) or volumetric-modulated arc therapy (VMAT). Methods Two time-series forecasting algorithms, autoregressive (AR) modeling and deep-learning-based long short-term memory (LSTM), were applied to predict the diaphragm position in the next 2D BEV cine to identify a motion-matched and hysteresis-accounted image to retrieve the tumor volume from the inhalation/exhalation TR-4DMRI libraries. Three 40-s TR-4DMRI (2 Hz, 3 × 80 images) per patient of eight lung cancer patients were used to create patient-specific inhalation/exhalation 4DMRI libraries, extract diaphragmatic waveforms, and interpolate them to f = 4 and 8 Hz to match 2D cine frame rates. Along a (40•f)-timepoint waveform, 30•f training timepoints were moved forward to produce 3×(10•f-1) predictions. The accuracy of position prediction was assessed against the waveform ground truth. The accuracy of tumor volume projections was evaluated using the center-of-mass difference (∆COM) and Dice similarity index against the TR-4DMRI ground truth for both IMRT (six beam angles, 30° interval) and VMAT (240/480 beam angles, 1.5°/0.75° interval, at 4/8 Hz, respectively). Results The accuracy of the first-timepoint prediction is 0.36 ± 0.10 mm (AR) and 0.62 ± 0.21 mm (LSTM) at 4 Hz and 0.06 ± 0.02 mm (AR) and 0.18 ± 0.06 mm (LSTM) at 8 Hz. A 10%–20% random error in prediction-library matching increases the overall uncertainty slightly. For both IMRT and VMAT, the accuracy of projected tumor volume contours on 2D BEV cine is ∆COM = 0.39 ± 0.13 mm and DICE = 0.97 ± 0.02 at 4 Hz and ∆COM = 0.10 ± 0.04 mm and DICE = 1.00 ± 0.00 at 8Hz. Conclusion This study demonstrates the feasibility of accurately predicting respiratory motion during 2D BEV cine imaging, identifying a motion-matched and hysteresis-accounted tumor volume, and projecting tumor volume contour on 2D BEV cine for real-time assessment of beam-to-tumor conformality, promising for optimal personalized MR-guided radiotherapy.
Collapse
Affiliation(s)
- Xingyu Nie
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States.,Department of Radiology, University of Kentucky, Lexington, KY, United States
| | - Guang Li
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| |
Collapse
|
19
|
Kuah T, Vellayappan BA, Makmur A, Nair S, Song J, Tan JH, Kumar N, Quek ST, Hallinan JTPD. State-of-the-Art Imaging Techniques in Metastatic Spinal Cord Compression. Cancers (Basel) 2022; 14:cancers14133289. [PMID: 35805059 PMCID: PMC9265325 DOI: 10.3390/cancers14133289] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 06/24/2022] [Accepted: 06/28/2022] [Indexed: 12/23/2022] Open
Abstract
Metastatic Spinal Cord Compression (MSCC) is a debilitating complication in oncology patients. This narrative review discusses the strengths and limitations of various imaging modalities in diagnosing MSCC, the role of imaging in stereotactic body radiotherapy (SBRT) for MSCC treatment, and recent advances in deep learning (DL) tools for MSCC diagnosis. PubMed and Google Scholar databases were searched using targeted keywords. Studies were reviewed in consensus among the co-authors for their suitability before inclusion. MRI is the gold standard of imaging to diagnose MSCC with reported sensitivity and specificity of 93% and 97% respectively. CT Myelogram appears to have comparable sensitivity and specificity to contrast-enhanced MRI. Conventional CT has a lower diagnostic accuracy than MRI in MSCC diagnosis, but is helpful in emergent situations with limited access to MRI. Metal artifact reduction techniques for MRI and CT are continually being researched for patients with spinal implants. Imaging is crucial for SBRT treatment planning and three-dimensional positional verification of the treatment isocentre prior to SBRT delivery. Structural and functional MRI may be helpful in post-treatment surveillance. DL tools may improve detection of vertebral metastasis and reduce time to MSCC diagnosis. This enables earlier institution of definitive therapy for better outcomes.
Collapse
Affiliation(s)
- Tricia Kuah
- Department of Diagnostic Imaging, National University Hospital, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore; (A.M.); (S.N.); (J.S.); (S.T.Q.); (J.T.P.D.H.)
- Correspondence: ; Tel.: +65-6779-5555
| | - Balamurugan A. Vellayappan
- Department of Radiation Oncology, National University Cancer Institute Singapore, National University Hospital, Singapore 119074, Singapore;
| | - Andrew Makmur
- Department of Diagnostic Imaging, National University Hospital, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore; (A.M.); (S.N.); (J.S.); (S.T.Q.); (J.T.P.D.H.)
- Department of Diagnostic Radiology, Yong Loo Lin School of Medicine, National University of Singapore, 10 Medical Drive, Singapore 117597, Singapore
| | - Shalini Nair
- Department of Diagnostic Imaging, National University Hospital, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore; (A.M.); (S.N.); (J.S.); (S.T.Q.); (J.T.P.D.H.)
| | - Junda Song
- Department of Diagnostic Imaging, National University Hospital, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore; (A.M.); (S.N.); (J.S.); (S.T.Q.); (J.T.P.D.H.)
| | - Jiong Hao Tan
- University Spine Centre, Department of Orthopaedic Surgery, National University Health System, 1E Lower Kent Ridge Road, Singapore 119228, Singapore; (J.H.T.); (N.K.)
| | - Naresh Kumar
- University Spine Centre, Department of Orthopaedic Surgery, National University Health System, 1E Lower Kent Ridge Road, Singapore 119228, Singapore; (J.H.T.); (N.K.)
| | - Swee Tian Quek
- Department of Diagnostic Imaging, National University Hospital, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore; (A.M.); (S.N.); (J.S.); (S.T.Q.); (J.T.P.D.H.)
- Department of Diagnostic Radiology, Yong Loo Lin School of Medicine, National University of Singapore, 10 Medical Drive, Singapore 117597, Singapore
| | - James Thomas Patrick Decourcy Hallinan
- Department of Diagnostic Imaging, National University Hospital, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore; (A.M.); (S.N.); (J.S.); (S.T.Q.); (J.T.P.D.H.)
- Department of Diagnostic Radiology, Yong Loo Lin School of Medicine, National University of Singapore, 10 Medical Drive, Singapore 117597, Singapore
| |
Collapse
|
20
|
CT-MR Image Fusion for Post-Implant Dosimetry Analysis in Brain Tumor Seed Implantation- a Preliminary Study. DISEASE MARKERS 2022; 2022:6310262. [PMID: 35620270 PMCID: PMC9129983 DOI: 10.1155/2022/6310262] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 04/19/2022] [Accepted: 04/22/2022] [Indexed: 12/17/2022]
Abstract
Purpose To calculate and evaluate postimplant dosimetry (PID) with CT-MR fusion technique after brain tumor brachytherapy and compare the result with CT-based PID. Methods and Materials 16 brain tumor patients received MR-guided intervention with Iodine-125 (125I) seed implantation entered this preliminary study for PID evaluation. Registration and fusion of CT and MR images of the same patients were performed one day after operation. Seeds identification and targets delineation were carried out on CT, MR, and CT-MR fusion images, each. The number and location of seeds on MR or CT- MR fusion images were compared with those of actually implanted seeds. Clinical target volume (CTV) and dosimetric parameters such as %D90, %V100 and external V100 were measured and calculated. In addition, the correlation of the fusion to CT CTV ratio and other factors were analyzed. Results The numbers of fusion seeds were not significantly different compared with reference seeds (t =1.76, p >0.05). The difference between reference seeds numbers and truly extracted MR seeds numbers was statistically significant (t =3.91, p <0.05). All dosimetric parameters showed significant differences between the two techniques (p <0.05). The mean CTV delineated on fusion images was 34.3 ± 33.6, smaller than that on CT images. The mean values of external V100, %V100 and %D90 on fusion images were larger than those on CT images. Correlation analysis showed that the fusion-CT V100 ratio was positively and significantly correlated with the fusion-CT volume ratio. Conclusions This preliminary study indicated that CT-MR fusion-based PID exhibited good accuracy for 125I brain tumor brachytherapy dosimetry when compared to CT-based PID and merits further research to establish best-outcome protocols.
Collapse
|
21
|
MRI-LINAC dosimetry approach by Monte Carlo codes coupling charged particle radiation transport with strong magnetic fields. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
22
|
Fu Y, Zhang H, Morris ED, Glide-Hurst CK, Pai S, Traverso A, Wee L, Hadzic I, Lønne PI, Shen C, Liu T, Yang X. Artificial Intelligence in Radiation Therapy. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022; 6:158-181. [PMID: 35992632 PMCID: PMC9385128 DOI: 10.1109/trpms.2021.3107454] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Artificial intelligence (AI) has great potential to transform the clinical workflow of radiotherapy. Since the introduction of deep neural networks, many AI-based methods have been proposed to address challenges in different aspects of radiotherapy. Commercial vendors have started to release AI-based tools that can be readily integrated to the established clinical workflow. To show the recent progress in AI-aided radiotherapy, we have reviewed AI-based studies in five major aspects of radiotherapy including image reconstruction, image registration, image segmentation, image synthesis, and automatic treatment planning. In each section, we summarized and categorized the recently published methods, followed by a discussion of the challenges, concerns, and future development. Given the rapid development of AI-aided radiotherapy, the efficiency and effectiveness of radiotherapy in the future could be substantially improved through intelligent automation of various aspects of radiotherapy.
Collapse
Affiliation(s)
- Yabo Fu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Hao Zhang
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA
| | - Eric D. Morris
- Department of Radiation Oncology, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - Carri K. Glide-Hurst
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI 53792, USA
| | - Suraj Pai
- Maastricht University Medical Centre, Netherlands
| | | | - Leonard Wee
- Maastricht University Medical Centre, Netherlands
| | | | - Per-Ivar Lønne
- Department of Medical Physics, Oslo University Hospital, PO Box 4953 Nydalen, 0424 Oslo, Norway
| | - Chenyang Shen
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75002, USA
| | - Tian Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, USA
| |
Collapse
|
23
|
Sanders JW, Mok H, Hanania AN, Venkatesan AM, Tang C, Bruno TL, Thames HD, Kudchadker RJ, Frank SJ. Computer-aided segmentation on MRI for prostate radiotherapy, Part I: Quantifying human interobserver variability of the prostate and organs at risk and its impact on radiation dosimetry. Radiother Oncol 2021; 169:124-131. [PMID: 34921895 DOI: 10.1016/j.radonc.2021.12.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 11/13/2021] [Accepted: 12/08/2021] [Indexed: 10/19/2022]
Abstract
BACKGROUND AND PURPOSE Quantifying the interobserver variability (IoV) of prostate and periprostatic anatomy delineation on prostate MRI is necessary to inform its use for treatment planning, treatment delivery, and treatment quality assessment. MATERIALS AND METHODS Twenty five prostate cancer patients underwent MRI-based low-dose-rate prostate brachytherapy (LDRPBT). The patients were scanned with a 3D T2-weighted sequence for treatment planning and a 3D T2/T1-weighted sequence for quality assessment. Seven observers involved with the LDRPBT workflow delineated the prostate, external urinary sphincter (EUS), seminal vesicles, rectum, and bladder on all 50 MRIs. IoV was assessed by measuring contour similarity metrics, differences in organ volumes, and differences in dosimetry parameters between unique observer pairs. Measurements from a group of 3 radiation oncologists (G1) were compared against those from a group consisting of the other 4 clinical observers (G2). RESULTS IoV of the prostate was lower for G1 than G2 (Matthew's correlation coefficient [MCC], G1 vs. G2: planning-0.906 vs. 0.870, p < 0.001; postimplant-0.899 vs. 0.861, p < 0.001). IoV of the EUS was highest of all the organs for both groups, but was lower for G1 (MCC, G1 vs. G2: planning-0.659 vs. 0.402, p < 0.001; postimplant-0.684 vs. 0.398, p < 0.001). Large differences in prostate dosimetry parameters were observed (G1 maximum absolute prostate ΔD90: planning-76.223 Gy, postimplant-36.545 Gy; G1 maximum absolute prostate ΔV100: planning-13.927%, postimplant-8.860%). CONCLUSIONS While MRI is optimal in the management of prostate cancer with radiation therapy, significant interobserver variability of the prostate and external urinary sphincter still exist.
Collapse
Affiliation(s)
- Jeremiah W Sanders
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, USA.
| | - Henry Mok
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, USA
| | | | - Aradhana M Venkatesan
- Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, USA
| | - Chad Tang
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, USA
| | - Teresa L Bruno
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, USA
| | - Howard D Thames
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, USA.
| | - Rajat J Kudchadker
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, USA
| | - Steven J Frank
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, USA
| |
Collapse
|
24
|
Lui JCF, Tang AM, Law CC, Lee JCY, Lee FKH, Chiu J, Wong KH. A practical methodology to improve the dosimetric accuracy of MR-based radiotherapy simulation for brain tumors. Phys Med 2021; 91:1-12. [PMID: 34678686 DOI: 10.1016/j.ejmp.2021.10.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 10/04/2021] [Accepted: 10/05/2021] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To investigate the dosimetric accuracy of synthetic computed tomography (sCT) images generated by a clinically-ready voxel-based MRI simulation package, and to develop a simple and feasible method to improve the accuracy. METHODS 20 patients with brain tumor were selected to undergo CT and MRI simulation. sCT images were generated by a clinical MRI simulation package. The discrepancy between planning CT and sCT in CT number and body contour were evaluated. To resolve the discrepancies, an sCT specific CT-relative electron density (RED) calibration curve was used, and a layer of pseudo-skin was created on the sCT. The dosimetric impact of these discrepancies, and the improvement brought about by the modifications, were evaluated by a planning study. Volumetric modulated arc therapy (VMAT) treatment plans for each patient were created and optimized on the planning CT, which were then transferred to the original sCT and the modified-sCT for dose re-calculation. Dosimetric comparisons and gamma analysis between the calculated doses in different images were performed. RESULTS The average gamma passing rate with 1%/1 mm criteria was only 70.8% for the comparison of dose distribution between planning CT and original sCT. The mean dose difference between the planning CT and the original sCT were -1.2% for PTV D95 and -1.7% for PTV Dmax, while the mean dose difference was within 0.7 Gy for all relevant OARs. After applying the modifications on the sCT, the average gamma passing rate was increased to 92.2%. Mean dose difference in PTV D95 and Dmax were reduced to -0.1% and -0.3% respectively. The mean dose difference was within 0.2 Gy for all OAR structures and no statistically significant difference were found. CONCLUSIONS The modified-sCT demonstrated improved dosimetric agreement with the planning CT. These results indicated the overall dosimetric accuracy and practicality of this improved MR-based treatment planning method.
Collapse
Affiliation(s)
- Jeffrey C F Lui
- Department of Clinical Oncology, Queen Elizabeth Hospital, Hong Kong.
| | - Annie M Tang
- Department of Clinical Oncology, Queen Elizabeth Hospital, Hong Kong
| | - C C Law
- Department of Clinical Oncology, Queen Elizabeth Hospital, Hong Kong
| | - Jonan C Y Lee
- Department of Radiology, Queen Elizabeth Hospital, Hong Kong
| | - Francis K H Lee
- Department of Clinical Oncology, Queen Elizabeth Hospital, Hong Kong
| | - Jeffrey Chiu
- Department of Radiology, Queen Elizabeth Hospital, Hong Kong
| | - Kam-Hung Wong
- Department of Clinical Oncology, Queen Elizabeth Hospital, Hong Kong
| |
Collapse
|
25
|
Chen Y, Lu L, Zhu T, Ma D. Technical overview of magnetic resonance fingerprinting and its applications in radiation therapy. Med Phys 2021; 49:2846-2860. [PMID: 34633687 DOI: 10.1002/mp.15254] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Revised: 08/23/2021] [Accepted: 09/17/2021] [Indexed: 11/07/2022] Open
Abstract
Magnetic resonance fingerprinting (MRF) is an emerging imaging technique for rapid and simultaneous quantification of multiple tissue properties. The technique has been developed for quantitative imaging of different organs. The obtained quantitative measures have the potential to improve multiple steps of a typical radiotherapy workflow and potentially further improve integration of magnetic resonance imaging guided clinical decision making. In this review paper, we first provide a technical overview of the MRF method from data acquisition to postprocessing, along with recent development in advanced reconstruction methods. We further discuss critical aspects that could influence its usage in radiation therapy, such as accuracy and precision, repeatability and reproducibility, geometric distortion, and motion robustness. Finally, future directions for MRF application in radiation therapy are discussed.
Collapse
Affiliation(s)
- Yong Chen
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Lan Lu
- Radiation Oncology, Cleveland Clinic, Cleveland, Ohio, USA
| | - Tong Zhu
- Radiation Oncology, Washington University in St Louis, St Louis, Missouri, USA
| | - Dan Ma
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
26
|
Chen Y, Gong G, Wang Y, Liu C, Su Y, Wang L, Yang B, Yin Y. Comparative Evaluation of 4-Dimensional Computed Tomography and 4-Dimensional Magnetic Resonance Imaging to Delineate the Target of Primary Liver Cancer. Technol Cancer Res Treat 2021; 20:15330338211045499. [PMID: 34617855 PMCID: PMC8504652 DOI: 10.1177/15330338211045499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Purpose: To evaluate the feasibility of 4-dimensional magnetic resonance imaging (4DMRI) in establishing the target of primary liver cancer in comparison with 4-dimensional computed tomography (4DCT). Methods and Materials: A total of 23 patients with primary liver cancer who received radiotherapy were selected, and 4DCT and T2w-4DMRI simulations were conducted to obtain 4DCT and T2w-4DMRI simulation images. The 4DCT and T2w-4DMRI data were sorted into 10 and 8 respiratory phase bins, respectively. The liver and gross tumor volumes (GTVs) were delineated in all images using programmed clinical workflows under tumor delineation guidelines. The internal organs at risk volumes (IRVs) and internal target volumes (ITVs) were the unions of all the phase livers and GTVs, respectively. Then, the artifacts, liver volume, GTV, and motion range in 4DCT and T2w-4DMRI were compared. Results: The mean GTV volume based on 4DMRI was 136.42 ± 231.27 cm3, which was 25.04 cm3 (15.5%) less than that of 4DCT (161.46 ± 280.29 cm3). The average volume of ITV determined by 4DMRI was 166.12 ± 270.43 cm3, which was 22.44 cm3 (11.9%) less than that determined by 4DCT (188.56 ± 307.57 cm3). Liver volume and IRV in 4DMRI increased by 4.0% and 6.6%, respectively, compared with 4DCT. The difference in tumor motion by T2w-4DMRI based on the centroid was greater than that of 4DCT in the L/R, A/P, and S/I directions, and the average displacement differences were 2.6, 2.8, and 6.9 mm, respectively. The severe artifacts in 4DCT were 47.8% (11/23) greater than in 4DMRI 17.4% (4/23). Conclusions: Compared with 4DCT, T2-weighted and navigator-triggered 4DMRI produces fewer artifacts and larger motion differences in hepatic intrafraction tumors, which is a feasible technique for primary liver cancer treatment planning.
Collapse
Affiliation(s)
- Yukai Chen
- East China University of Technology, Nanchang, Jiangxi, China
| | - Guanzhong Gong
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong Province, China
| | - Yinxing Wang
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong Province, China
| | - Chenlu Liu
- School of Nuclear Science and Technology, University of South China, Hengyang, China
| | - Ya Su
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong Province, China
| | - Lizhen Wang
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong Province, China
| | - Bo Yang
- East China University of Technology, Nanchang, Jiangxi, China
| | - Yong Yin
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong Province, China
| |
Collapse
|
27
|
Das IJ, Compton JJ, Bajaj A, Johnstone PA. Intra- and inter-physician variability in target volume delineation in radiation therapy. JOURNAL OF RADIATION RESEARCH 2021:rrab080. [PMID: 34505151 DOI: 10.1093/jrr/rrab080] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 05/17/2021] [Indexed: 06/13/2023]
Abstract
Reduction in setup errors is advocated through daily imaging and adaptive therapy, where the target volume is drawn daily. Previous studies suggest that inter-physician volume variation is significant (1.5 cm standard deviation [SD]); however, there are limited data for intra-physician consistency in daily target volume delineation, which is investigated in this study. Seven patients with lung cancer were chosen based on the perceived difficulty of contouring their disease, varying from simple parenchymal lung nodules to lesions with extensive adjacent atelectasis. Four physicians delineated the gross tumor volume (GTV) for each patient on 10 separate days to see the intra- and inter-physician contouring. Isocenter coordinates (x, y and z), target volume (cm3), and largest dimensions on anterior-posterior (AP) and lateral views were recorded for each GTV. Our results show that the variability among the physicians was reflected by target volumes ranging from +109% to -86% from the mean while isocenter coordinate changes were minimal; 3.8, 1.7 and 1.9 mm for x, y and z coordinates, respectively. The orthogonal image (AP and lateral) change varied 16.3 mm and 15.0 mm respectively among days and physicians. We conclude than when performing daily imaging, random variability in contouring resulted in isocenter changes up to ±3.8 mm in our study. The shape of the target varied within ±16 mm. This study suggests that when using daily imaging to track isocenter, target volume, or treatment parameters, physicians should be aware of personal variability when considering margins added to the target volume in daily decision making especially for difficult cases.
Collapse
Affiliation(s)
- Indra J Das
- Department of Radiation Oncology, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
| | - Julia J Compton
- Hancock Regional Hospital, Sue Ann Wortman Cancer Center, 801 N State St, Greenfield, IN 46410, USA
| | - Amishi Bajaj
- Department of Radiation Oncology, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
| | - Peter A Johnstone
- Department of Radiation Oncology, Lee Moffitt Cancer Center, Magnolia Dr, Tampa, FL 33612, USA
| |
Collapse
|
28
|
Dai X, Lei Y, Wang T, Zhou J, Roper J, McDonald M, Beitler JJ, Curran WJ, Liu T, Yang X. Automated delineation of head and neck organs at risk using synthetic MRI-aided mask scoring regional convolutional neural network. Med Phys 2021; 48:5862-5873. [PMID: 34342878 DOI: 10.1002/mp.15146] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 06/30/2021] [Accepted: 07/25/2021] [Indexed: 01/10/2023] Open
Abstract
PURPOSE Auto-segmentation algorithms offer a potential solution to eliminate the labor-intensive, time-consuming, and observer-dependent manual delineation of organs-at-risk (OARs) in radiotherapy treatment planning. This study aimed to develop a deep learning-based automated OAR delineation method to tackle the current challenges remaining in achieving reliable expert performance with the state-of-the-art auto-delineation algorithms. METHODS The accuracy of OAR delineation is expected to be improved by utilizing the complementary contrasts provided by computed tomography (CT) (bony-structure contrast) and magnetic resonance imaging (MRI) (soft-tissue contrast). Given CT images, synthetic MR images were firstly generated by a pre-trained cycle-consistent generative adversarial network. The features of CT and synthetic MRI were then extracted and combined for the final delineation of organs using mask scoring regional convolutional neural network. Both in-house and public datasets containing CT scans from head-and-neck (HN) cancer patients were adopted to quantitatively evaluate the performance of the proposed method against current state-of-the-art algorithms in metrics including Dice similarity coefficient (DSC), 95th percentile Hausdorff distance (HD95), mean surface distance (MSD), and residual mean square distance (RMS). RESULTS Across all of 18 OARs in our in-house dataset, the proposed method achieved an average DSC, HD95, MSD, and RMS of 0.77 (0.58-0.90), 2.90 mm (1.32-7.63 mm), 0.89 mm (0.42-1.85 mm), and 1.44 mm (0.71-3.15 mm), respectively, outperforming the current state-of-the-art algorithms by 6%, 16%, 25%, and 36%, respectively. On public datasets, for all nine OARs, an average DSC of 0.86 (0.73-0.97) were achieved, 6% better than the competing methods. CONCLUSION We demonstrated the feasibility of a synthetic MRI-aided deep learning framework for automated delineation of OARs in HN radiotherapy treatment planning. The proposed method could be adopted into routine HN cancer radiotherapy treatment planning to rapidly contour OARs with high accuracy.
Collapse
Affiliation(s)
- Xianjin Dai
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Yang Lei
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Tonghe Wang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Jun Zhou
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Justin Roper
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Mark McDonald
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Jonathan J Beitler
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Walter J Curran
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Tian Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| |
Collapse
|
29
|
van Houdt PJ, Saeed H, Thorwarth D, Fuller CD, Hall WA, McDonald BA, Shukla-Dave A, Kooreman ES, Philippens MEP, van Lier ALHMW, Keesman R, Mahmood F, Coolens C, Stanescu T, Wang J, Tyagi N, Wetscherek A, van der Heide UA. Integration of quantitative imaging biomarkers in clinical trials for MR-guided radiotherapy: Conceptual guidance for multicentre studies from the MR-Linac Consortium Imaging Biomarker Working Group. Eur J Cancer 2021; 153:64-71. [PMID: 34144436 PMCID: PMC8340311 DOI: 10.1016/j.ejca.2021.04.041] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Accepted: 04/27/2021] [Indexed: 12/14/2022]
Abstract
Quantitative imaging biomarkers (QIBs) derived from MRI techniques have the potential to be used for the personalised treatment of cancer patients. However, large-scale data are missing to validate their added value in clinical practice. Integrated MRI-guided radiotherapy (MRIgRT) systems, such as hybrid MRI-linear accelerators, have the unique advantage that MR images can be acquired during every treatment session. This means that high-frequency imaging of QIBs becomes feasible with reduced patient burden, logistical challenges, and costs compared to extra scan sessions. A wealth of valuable data will be collected before and during treatment, creating new opportunities to advance QIB research at large. The aim of this paper is to present a roadmap towards the clinical use of QIBs on MRIgRT systems. The most important need is to gather and understand how the QIBs collected during MRIgRT correlate with clinical outcomes. As the integrated MRI scanner differs from traditional MRI scanners, technical validation is an important aspect of this roadmap. We propose to integrate technical validation with clinical trials by the addition of a quality assurance procedure at the start of a trial, the acquisition of in vivo test-retest data to assess the repeatability, as well as a comparison between QIBs from MRIgRT systems and diagnostic MRI systems to assess the reproducibility. These data can be collected with limited extra time for the patient. With integration of technical validation in clinical trials, the results of these trials derived on MRIgRT systems will also be applicable for measurements on other MRI systems.
Collapse
Affiliation(s)
- Petra J van Houdt
- Department of Radiation Oncology, The Netherlands Cancer Institute, Plesmanlaan 102, Amsterdam, 1066CX, the Netherlands.
| | - Hina Saeed
- Department of Radiation Oncology, Medical College of Wisconsin, 9200 W Wisconsin Av, Milwaukee, WI, 53226, USA.
| | - Daniela Thorwarth
- Section for Biomedical Physics, Department of Radiation Oncology, University of Tübingen, Hoppe-Seyler-Str. 3, Tübingen, 72076, Germany.
| | - Clifton D Fuller
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 0097, Houston, TX, 77030, USA.
| | - William A Hall
- Department of Radiation Oncology, Medical College of Wisconsin, 9200 W Wisconsin Av, Milwaukee, WI, 53226, USA.
| | - Brigid A McDonald
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 0097, Houston, TX, 77030, USA.
| | - Amita Shukla-Dave
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA; Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Ernst S Kooreman
- Department of Radiation Oncology, The Netherlands Cancer Institute, Plesmanlaan 102, Amsterdam, 1066CX, the Netherlands.
| | - Marielle E P Philippens
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, the Netherlands.
| | - Astrid L H M W van Lier
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, the Netherlands.
| | - Rick Keesman
- Department of Radiation Oncology, Radboud University Medical Center, Geert Grooteplein Zuid 32, Nijmegen, 6525GA, the Netherlands.
| | - Faisal Mahmood
- Laboratory of Radiation Physics, Department of Oncology, Odense University Hospital, Kløvervænget 19, Odense C, 5000, Denmark; Department of Clinical Research, University of Southern Denmark, J. B. Winsløws Vej 19.3, Odense C, 5000, Denmark.
| | - Catherine Coolens
- Department of Medical Physics, Princess Margaret Cancer Centre and University Health Network, 700 University Avenue, Toronto, Ontario, M5M 1G7, Canada.
| | - Teodor Stanescu
- Department of Medical Physics, Princess Margaret Cancer Centre and University Health Network, 700 University Avenue, Toronto, Ontario, M5M 1G7, Canada; Department of Radiation Oncology, University of Toronto, 610 University Avenue, Toronto, Ontario, M5G 2M9, Canada.
| | - Jihong Wang
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 0097, Houston, TX, 77030, USA.
| | - Neelam Tyagi
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Andreas Wetscherek
- Joint Department of Physics, The Institute of Cancer Research and the Royal Marsden NHS Foundation Trust, 15 Cotswold Road, London, SM2 5NG, United Kingdom.
| | - Uulke A van der Heide
- Department of Radiation Oncology, The Netherlands Cancer Institute, Plesmanlaan 102, Amsterdam, 1066CX, the Netherlands.
| |
Collapse
|
30
|
Wang J, Salzillo T, Jiang Y, Mackeyev Y, David Fuller C, Chung C, Choi S, Hughes N, Ding Y, Yang J, Vedam S, Krishnan S. Stability of MRI contrast agents in high-energy radiation of a 1.5T MR-Linac. Radiother Oncol 2021; 161:55-64. [PMID: 34089753 PMCID: PMC8324543 DOI: 10.1016/j.radonc.2021.05.023] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Revised: 05/24/2021] [Accepted: 05/26/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND Gadolinium-based contrast is often used when acquiring MR images for radiation therapy planning for better target delineation. In some situations, patients may still have residual MRI contrast agents in their tissue while being treated with high-energy radiation. This is especially true when MRI contrast agents are administered during adaptive treatment replanning for patients treated on MR-Linac systems. PURPOSE The purpose of this study was to analyze the molecular stability of MRI contrast agents when exposed to high energy photons and the associated secondary electrons in a 1.5T MR-Linac system. This was the first step in assessing the safety of administering MRI contrast agents throughout the course of treatment. MATERIALS AND METHODS Two common MRI contrast agents were irradiated with 7 MV photons to clinical dose levels. The irradiated samples were analyzed using liquid chromatography-high resolution mass spectrometry to detect degradation products or conformational alterations created by irradiation with high energy photons and associated secondary electrons. RESULTS No significant change in chemical composition or displacement of gadolinium ions from their chelates was discovered in samples irradiated with 7 MV photons at relevant clinical doses in a 1.5T MR-Linac. Additionally, no significant correlation between concentrations of irradiated MRI contrast agents and radiation dose was observed. CONCLUSION The chemical composition stability of the irradiated contrast agents is promising for future use throughout the course of patient treatment. However, in vivo studies are needed to confirm that unexpected metabolites are not created in biological milieus.
Collapse
Affiliation(s)
- Jihong Wang
- Department of Radiation Physics, MD Anderson Cancer Center, Houston, United States.
| | - Travis Salzillo
- Department of Radiation Oncology, MD Anderson Cancer Center, Houston, United States
| | - Yongying Jiang
- The Institute for Applied Cancer Science, MD Anderson Cancer Center, Houston, United States
| | - Yuri Mackeyev
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, United States
| | - Clifton David Fuller
- Department of Radiation Oncology, MD Anderson Cancer Center, Houston, United States
| | - Caroline Chung
- Department of Radiation Oncology, MD Anderson Cancer Center, Houston, United States
| | - Seungtaek Choi
- Department of Radiation Oncology, MD Anderson Cancer Center, Houston, United States
| | - Neil Hughes
- Department of Radiation Oncology, MD Anderson Cancer Center, Houston, United States
| | - Yao Ding
- Department of Radiation Physics, MD Anderson Cancer Center, Houston, United States
| | - Jinzhong Yang
- Department of Radiation Physics, MD Anderson Cancer Center, Houston, United States
| | - Sastry Vedam
- Department of Radiation Oncology, University of Maryland, Baltimore, United States
| | - Sunil Krishnan
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, United States
| |
Collapse
|
31
|
Groot Koerkamp ML, de Hond YJM, Maspero M, Kontaxis C, Mandija S, Vasmel JE, Charaghvandi RK, Philippens MEP, van Asselen B, van den Bongard HJGD, Hackett SS, Houweling AC. Synthetic CT for single-fraction neoadjuvant partial breast irradiation on an MRI-linac. Phys Med Biol 2021; 66. [PMID: 33761491 DOI: 10.1088/1361-6560/abf1ba] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Accepted: 03/24/2021] [Indexed: 01/08/2023]
Abstract
A synthetic computed tomography (sCT) is required for daily plan optimization on an MRI-linac. Yet, only limited information is available on the accuracy of dose calculations on sCT for breast radiotherapy. This work aimed to (1) evaluate dosimetric accuracy of treatment plans for single-fraction neoadjuvant partial breast irradiation (PBI) on a 1.5 T MRI-linac calculated on a) bulk-density sCT mimicking the current MRI-linac workflow and b) deep learning-generated sCT, and (2) investigate the number of bulk-density levels required. For ten breast cancer patients we created three bulk-density sCTs of increasing complexity from the planning-CT, using bulk-density for: (1) body, lungs, and GTV (sCTBD1); (2) volumes for sCTBD1plus chest wall and ipsilateral breast (sCTBD2); (3) volumes for sCTBD2plus ribs (sCTBD3); and a deep learning-generated sCT (sCTDL) from a 1.5 T MRI in supine position. Single-fraction neoadjuvant PBI treatment plans for a 1.5 T MRI-linac were optimized on each sCT and recalculated on the planning-CT. Image evaluation was performed by assessing mean absolute error (MAE) and mean error (ME) in Hounsfield Units (HU) between the sCTs and the planning-CT. Dosimetric evaluation was performed by assessing dose differences, gamma pass rates, and dose-volume histogram (DVH) differences. The following results were obtained (median across patients for sCTBD1/sCTBD2/sCTBD3/sCTDLrespectively): MAE inside the body contour was 106/104/104/75 HU and ME was 8/9/6/28 HU, mean dose difference in the PTVGTVwas 0.15/0.00/0.00/-0.07 Gy, median gamma pass rate (2%/2 mm, 10% dose threshold) was 98.9/98.9/98.7/99.4%, and differences in DVH parameters were well below 2% for all structures except for the skin in the sCTDL. Accurate dose calculations for single-fraction neoadjuvant PBI on an MRI-linac could be performed on both bulk-density and deep learning sCT, facilitating further implementation of MRI-guided radiotherapy for breast cancer. Balancing simplicity and accuracy, sCTBD2showed the optimal number of bulk-density levels for a bulk-density approach.
Collapse
Affiliation(s)
- M L Groot Koerkamp
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Y J M de Hond
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, The Netherlands.,Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - M Maspero
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, The Netherlands.,Computational Imaging Group for MR diagnostics & therapy, Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
| | - C Kontaxis
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - S Mandija
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, The Netherlands.,Computational Imaging Group for MR diagnostics & therapy, Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
| | - J E Vasmel
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - R K Charaghvandi
- Department of Radiation Oncology, Radboudumc, Nijmegen, The Netherlands
| | - M E P Philippens
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - B van Asselen
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, The Netherlands
| | | | - S S Hackett
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - A C Houweling
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
32
|
Prospective Image Quality and Lesion Assessment in the Setting of MR-Guided Radiation Therapy of Prostate Cancer on an MR-Linac at 1.5 T: A Comparison to a Standard 3 T MRI. Cancers (Basel) 2021; 13:cancers13071533. [PMID: 33810410 PMCID: PMC8036991 DOI: 10.3390/cancers13071533] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 03/19/2021] [Accepted: 03/24/2021] [Indexed: 12/11/2022] Open
Abstract
Simple Summary High-precision MR-guided radiotherapy (MRgRT) constitutes the state-of-the-art in the sphere of personalized prostate cancer treatment. To this end, integrating a 1.5 T scanner with a linear accelerator led to the development of MR-Linac (MRL), which could be considered a novel deflection point in radiation oncology. Since the success of both diagnosis and radiation treatment is highly dependent on image quality, geometric integrity, and lesion conspicuity, it is important to investigate the quality of these sequences in comparison to the current diagnostic gold standard multiparametric MRI at 3T (MRI3T), which has not been done before. The purpose of this study is to conduct a qualitative and a quantitative analysis of MRL-images at 1.5 T in patients undergoing MRgRT planning for prostate cancer. Results from this study pave the way for developing safer and more efficient planning workflows in patients with prostate cancer undergoing MR-guided radiotherapy. Abstract The objective of this study is to conduct a qualitative and a quantitative image quality and lesion evaluation in patients undergoing MR-guided radiation therapy (MRgRT) for prostate cancer on a hybrid magnetic resonance imaging and linear accelerator system (MR-Linac or MRL) at 1.5 Tesla. This prospective study was approved by the institutional review board. A total of 13 consecutive patients with biopsy-confirmed prostate cancer and an indication for MRgRT were included. Prior to radiation therapy, each patient underwent an MR-examination on an MRL and on a standard MRI scanner at 3 Tesla (MRI3T). Three readers (two radiologists and a radiation oncologist) conducted an independent qualitative and quantitative analysis of T2-weighted (T2w) and diffusion-weighted images (DWI). Qualitative outcome measures were as follows: zonal anatomy, capsule demarcation, resolution, visibility of the seminal vesicles, geometric distortion, artifacts, overall image quality, lesion conspicuity, and diagnostic confidence. All ratings were performed on an ordinal 4-point Likert scale. Lesion conspicuity and diagnostic confidence were firstly analyzed only on MRL. Afterwards, these outcome parameters were analyzed in consensus with the MRI3T. Quantitative outcome measures were as follows: anteroposterior and right left diameter of the prostate, lesion size, PI-RADS score (Prostate Imaging—Reporting and Data System) and apparent diffusion coefficient (ADC) of the lesions. Intergroup comparisons were computed using the Wilcoxon-sign rank test and t tests. A post-hoc regression analysis was computed for lesion evaluation. Finally, inter-/intra-reader agreement was analyzed using the Fleiss kappa and intraclass correlation coefficient. For T2w images, the MRL showed good results across all quality criteria (median 3 and 4). Furthermore, there were no significant differences between MRL and MRI3T regarding capsule demarcation or geometric distortion. For the DWI, the MRL performed significantly less than MRI3T across most image quality criteria with a median ranging between 2 and 3. However, there were no significant differences between MRL and MRI3T regarding geometric distortion. In terms of lesion conspicuity and diagnostic confidence, inter-reader agreement was fair for MRL alone (Kappa = 0.42) and good for MRL in consensus with MRI3T (Kappa = 0.708). Thus, lesion conspicuity and diagnostic confidence could be significantly improved when reading MRL images in consensus with MRI3T (Odds ratio: 9- to 11-fold for the T2w images and 5- to 8–fold for the DWI) (p < 0.001). For measures of lesion size, anterior-posterior and right-left prostate diameter, inter-reader and intersequence agreement were excellent (ICC > 0.90) and there were no significant differences between MRL and MRI3T among all three readers. In terms of Prostate Imaging Reporting and Data System (PIRADS) scoring, no significant differences were observed between MRL and MRI3T. Finally, there was a significant positive linear relationship between lesion ADC measurements (r = 0.76, p < 0.01) between the ADC values measured on both systems. In conclusion, image quality for T2w was comparable and diagnostic even without administration of spasmolytic- or contrast agents, while DWI images did not reach diagnostic level and need to be optimized for further exploitation in the setting of MRgRT. Diagnostic confidence and lesion conspicuity were significantly improved by reading MRL in consensus with MRI3T which would be advisable for a safe planning and treatment workflow. Finally, ADC measurements of lesions on both systems were comparable indicating that, lesion ADC as measured on the MRL could be used as a biomarker for evaluation of treatment response, similar to examinations using MRI3T.
Collapse
|
33
|
Ramachandran P, Noble C, Langton C, Perrett B, Cox J, Chapman M, McGill G. A 3D printed phantom to assess MRI geometric distortion. Biomed Phys Eng Express 2021; 7. [PMID: 33657539 DOI: 10.1088/2057-1976/abeb7e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Accepted: 03/03/2021] [Indexed: 11/12/2022]
Abstract
Magnetic Resonance has become a standard imaging modality for target volume delineation and treatment planning in radiation oncology. Geometric distortions, however, have the potential to detrimentally affect both tumour definition and the dose delivered to the target volume. We report the design, fabrication and imaging of a 3D printed unibody MR distortion phantom along with quantitative image analysis. METHODS The internal cavity of the phantom is an orthogonal three-dimensional planar lattice, composed of 3mm diameter rods spaced equidistantly at a 20mm centre-centre offset repeating along the X, Y and Z axes. The phantom featured an overall length of 308.5 mm, a width of 246 mm and a height of 264 mm with lines on the external surface for phantom positioning matched to external lasers. The MR phantom was 3D printed in Nylon-12 using an advancement on traditional selective laser sintering (SLS) (HP Jet Fusion 3D - 4200 machine). The phantom was scanned on a Toshiba Aquilion CT scanner to check the integrity of the 3D print and to correct for any resultant issues. The phantom was then filled with NiSO4 solution and scanned on a 3T PET-MR Siemens scanner for selected T1 and T2 sequences, from which distortion vectors were generated and analysed using in-house software written in Python. RESULTS All deviations were less than 1 mm, with an average displacement of 0.228 mm. The majority of the deviations are smaller than the 0.692 mm pixel size for this dataset. CONCLUSION A cost-effective, 3D printed MRI-phantom was successfully printed and tested for assessing geometric distortion on MRI scanners. The custom phantom with markings for phantom alignment may be considered for radiotherapy departments looking to add MR scanners for simulation and image guidance.
Collapse
Affiliation(s)
- Prabhakar Ramachandran
- Radiation Oncology, Princess Alexandra Hospital, 199 Ipswich Road, Woolloongabba, Woolloongabba, Queensland, 4102, AUSTRALIA
| | - Chris Noble
- Department of Radiation Oncology, Princess Alexandra Hospital, 199 Ipswich Rd, Woolloongabba, 4102, AUSTRALIA
| | - Christian Langton
- Clinical Sciences, Queensland University of Technology, 3D One, Brisbane, 4107, AUSTRALIA
| | - Ben Perrett
- Department of Radiation Oncology, Princess Alexandra Hospital, 199 Ipswich Road, Woolloongabba, 4102, AUSTRALIA
| | - Joshua Cox
- One Australia Pty Ltd, 3D one, Salisbury, 4107, AUSTRALIA
| | - Mike Chapman
- One Australia Pty Ltd, 3D one, Salisbury, 4107, AUSTRALIA
| | - George McGill
- Queensland University of Technology, 199 Ipswich Road, Brisbane, 4102, AUSTRALIA
| |
Collapse
|
34
|
Paganetti H, Beltran C, Both S, Dong L, Flanz J, Furutani K, Grassberger C, Grosshans DR, Knopf AC, Langendijk JA, Nystrom H, Parodi K, Raaymakers BW, Richter C, Sawakuchi GO, Schippers M, Shaitelman SF, Teo BKK, Unkelbach J, Wohlfahrt P, Lomax T. Roadmap: proton therapy physics and biology. Phys Med Biol 2021; 66. [DOI: 10.1088/1361-6560/abcd16] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Accepted: 11/23/2020] [Indexed: 12/12/2022]
|
35
|
Nie X, Rimner A, Li G. Feasibility of MR-guided radiotherapy using beam-eye-view 2D-cine with tumor-volume projection. Phys Med Biol 2021; 66:045020. [PMID: 33361569 DOI: 10.1088/1361-6560/abd66a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
PURPOSE Current magnetic resonance imaging (MRI) guided radiotherapy (MRgRT) applies sagittal/coronal 2D-cine to monitor major tumor motions, however, the beam eye's view (BEV) with volumetric tumor projection would be the best measure for radiation beam conformality, independent of tumor through-plane motion. The goal is to assess the feasibility, accuracy, and performance of the BEV approach. METHODS Beam-specific BEV 2D-cine with volume-projected tumor contours were simulated to establish a 2D/3D tumor match against a tumor-motion library based on multi-breath time-resolved (TR) 4DMRI images. Two BEV-library-matching methods were developed: (1) fast screening with tumor center-of-mass (∆COM), in-plane area ratio, and DICE similarity, and finalizing with the highest DICE score and (2) DICE screening for top-3 candidates and finalizing with rigid registration. A 4D-XCAT digital phantom and 8 lung-cancer patients were used for assessment. For each patient, 3 sets of 40 s TR-4DMRI were acquired at 2 Hz and 6 representative BEV were created with the isocenter set at tumor COM in mid-respiration. One TR-4DMRI set (40 × 2 = 80-images) was used to simulate BEV 2D-cine and the other two (160-images) were used to create a library. The matching result was validated against the ground truth within the test set. Using a leave-one-out strategy, the success rate, accuracy, and speed of tumor matching were assessed for volume-projected tumors over 11520 time-points (=8patients•3sets•80images•6BEVs). RESULTS Volume-projected tumor contour area on the 6 BEVs varies by 60% ± 8% and [Formula: see text] (in-plane/volume-projected) varies by 82% ± 9%. The [Formula: see text] changes with tumor shape, orientation, and through-plane motion. Method-1 produces 96% matching success (ΔCOM = 0.7 ± 0.2 mm, [Formula: see text]=1.01 ± 0.02, Dice=0.92 ± 0.02) with the computational time of 15 ± 1 ms/match, while method-2 produces 94% ± 1% success (ΔCOM = 0.2 ± 0.1 mm, [Formula: see text]=1.00 ± 0.01, Dice = 0.94 ± 0.02) with 223 ± 13 ms/match. CONCLUSION This study has demonstrated the feasibility, accuracy, and benefits of BEV 2D-cine imaging with tumor-volume projection, allowing real-time tumor motion monitoring and beam conformality checking. Further clinical evaluation is necessary before MRgRT applications.
Collapse
Affiliation(s)
- Xingyu Nie
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, United States of America
| | | | | |
Collapse
|
36
|
Otazo R, Lambin P, Pignol JP, Ladd ME, Schlemmer HP, Baumann M, Hricak H. MRI-guided Radiation Therapy: An Emerging Paradigm in Adaptive Radiation Oncology. Radiology 2020; 298:248-260. [PMID: 33350894 DOI: 10.1148/radiol.2020202747] [Citation(s) in RCA: 73] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Radiation therapy (RT) continues to be one of the mainstays of cancer treatment. Considerable efforts have been recently devoted to integrating MRI into clinical RT planning and monitoring. This integration, known as MRI-guided RT, has been motivated by the superior soft-tissue contrast, organ motion visualization, and ability to monitor tumor and tissue physiologic changes provided by MRI compared with CT. Offline MRI is already used for treatment planning at many institutions. Furthermore, MRI-guided linear accelerator systems, allowing use of MRI during treatment, enable improved adaptation to anatomic changes between RT fractions compared with CT guidance. Efforts are underway to develop real-time MRI-guided intrafraction adaptive RT of tumors affected by motion and MRI-derived biomarkers to monitor treatment response and potentially adapt treatment to physiologic changes. These developments in MRI guidance provide the basis for a paradigm change in treatment planning, monitoring, and adaptation. Key challenges to advancing MRI-guided RT include real-time volumetric anatomic imaging, addressing image distortion because of magnetic field inhomogeneities, reproducible quantitative imaging across different MRI systems, and biologic validation of quantitative imaging. This review describes emerging innovations in offline and online MRI-guided RT, exciting opportunities they offer for advancing research and clinical care, hurdles to be overcome, and the need for multidisciplinary collaboration.
Collapse
Affiliation(s)
- Ricardo Otazo
- From the Departments of Medical Physics (R.O.) and Radiology (R.O., H.H.), Memorial Sloan-Kettering Cancer Center, 1275 York Ave, New York, NY 10065; The D-Lab, Department of Precision Medicine, Department of Radiology & Nuclear Medicine, GROW-School for Oncology, Maastricht University Medical Centre, Maastricht, the Netherlands (P.L.); Department of Radiation Oncology, Dalhousie University, Halifax, Canada (J.P.P.); Divisions of Medical Physics in Radiology (M.E.L.), Radiology (H.P.S.), and Radiation Oncology/Radiobiology (M.B.), German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Physics and Astronomy (M.E.L.) and Faculty of Medicine (M.E.L., M.B.), Heidelberg University, Heidelberg, Germany; and OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany (M.B.)
| | - Philippe Lambin
- From the Departments of Medical Physics (R.O.) and Radiology (R.O., H.H.), Memorial Sloan-Kettering Cancer Center, 1275 York Ave, New York, NY 10065; The D-Lab, Department of Precision Medicine, Department of Radiology & Nuclear Medicine, GROW-School for Oncology, Maastricht University Medical Centre, Maastricht, the Netherlands (P.L.); Department of Radiation Oncology, Dalhousie University, Halifax, Canada (J.P.P.); Divisions of Medical Physics in Radiology (M.E.L.), Radiology (H.P.S.), and Radiation Oncology/Radiobiology (M.B.), German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Physics and Astronomy (M.E.L.) and Faculty of Medicine (M.E.L., M.B.), Heidelberg University, Heidelberg, Germany; and OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany (M.B.)
| | - Jean-Philippe Pignol
- From the Departments of Medical Physics (R.O.) and Radiology (R.O., H.H.), Memorial Sloan-Kettering Cancer Center, 1275 York Ave, New York, NY 10065; The D-Lab, Department of Precision Medicine, Department of Radiology & Nuclear Medicine, GROW-School for Oncology, Maastricht University Medical Centre, Maastricht, the Netherlands (P.L.); Department of Radiation Oncology, Dalhousie University, Halifax, Canada (J.P.P.); Divisions of Medical Physics in Radiology (M.E.L.), Radiology (H.P.S.), and Radiation Oncology/Radiobiology (M.B.), German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Physics and Astronomy (M.E.L.) and Faculty of Medicine (M.E.L., M.B.), Heidelberg University, Heidelberg, Germany; and OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany (M.B.)
| | - Mark E Ladd
- From the Departments of Medical Physics (R.O.) and Radiology (R.O., H.H.), Memorial Sloan-Kettering Cancer Center, 1275 York Ave, New York, NY 10065; The D-Lab, Department of Precision Medicine, Department of Radiology & Nuclear Medicine, GROW-School for Oncology, Maastricht University Medical Centre, Maastricht, the Netherlands (P.L.); Department of Radiation Oncology, Dalhousie University, Halifax, Canada (J.P.P.); Divisions of Medical Physics in Radiology (M.E.L.), Radiology (H.P.S.), and Radiation Oncology/Radiobiology (M.B.), German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Physics and Astronomy (M.E.L.) and Faculty of Medicine (M.E.L., M.B.), Heidelberg University, Heidelberg, Germany; and OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany (M.B.)
| | - Heinz-Peter Schlemmer
- From the Departments of Medical Physics (R.O.) and Radiology (R.O., H.H.), Memorial Sloan-Kettering Cancer Center, 1275 York Ave, New York, NY 10065; The D-Lab, Department of Precision Medicine, Department of Radiology & Nuclear Medicine, GROW-School for Oncology, Maastricht University Medical Centre, Maastricht, the Netherlands (P.L.); Department of Radiation Oncology, Dalhousie University, Halifax, Canada (J.P.P.); Divisions of Medical Physics in Radiology (M.E.L.), Radiology (H.P.S.), and Radiation Oncology/Radiobiology (M.B.), German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Physics and Astronomy (M.E.L.) and Faculty of Medicine (M.E.L., M.B.), Heidelberg University, Heidelberg, Germany; and OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany (M.B.)
| | - Michael Baumann
- From the Departments of Medical Physics (R.O.) and Radiology (R.O., H.H.), Memorial Sloan-Kettering Cancer Center, 1275 York Ave, New York, NY 10065; The D-Lab, Department of Precision Medicine, Department of Radiology & Nuclear Medicine, GROW-School for Oncology, Maastricht University Medical Centre, Maastricht, the Netherlands (P.L.); Department of Radiation Oncology, Dalhousie University, Halifax, Canada (J.P.P.); Divisions of Medical Physics in Radiology (M.E.L.), Radiology (H.P.S.), and Radiation Oncology/Radiobiology (M.B.), German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Physics and Astronomy (M.E.L.) and Faculty of Medicine (M.E.L., M.B.), Heidelberg University, Heidelberg, Germany; and OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany (M.B.)
| | - Hedvig Hricak
- From the Departments of Medical Physics (R.O.) and Radiology (R.O., H.H.), Memorial Sloan-Kettering Cancer Center, 1275 York Ave, New York, NY 10065; The D-Lab, Department of Precision Medicine, Department of Radiology & Nuclear Medicine, GROW-School for Oncology, Maastricht University Medical Centre, Maastricht, the Netherlands (P.L.); Department of Radiation Oncology, Dalhousie University, Halifax, Canada (J.P.P.); Divisions of Medical Physics in Radiology (M.E.L.), Radiology (H.P.S.), and Radiation Oncology/Radiobiology (M.B.), German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Physics and Astronomy (M.E.L.) and Faculty of Medicine (M.E.L., M.B.), Heidelberg University, Heidelberg, Germany; and OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany (M.B.)
| |
Collapse
|
37
|
Yang L, Zheng T, Dong Y, Wang Z, Liu D, Du J, Wu S, Shi Q, Liu L. MRI Texture-Based Models for Predicting Mitotic Index and Risk Classification of Gastrointestinal Stromal Tumors. J Magn Reson Imaging 2020; 53:1054-1065. [PMID: 33037745 DOI: 10.1002/jmri.27390] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 09/23/2020] [Accepted: 09/25/2020] [Indexed: 01/09/2023] Open
Abstract
BACKGROUND Treatment regimens and prognoses of gastrointestinal stromal tumors (GIST) are quite different for tumors in different risk categories. Accurate preoperative grading of tumors is important for avoiding under- or overtreatment. PURPOSE To develop and validate an MRI texture-based model to predict the mitotic index and its risk classification. STUDY TYPE Retrospective. POPULATION Ninety-one patients with histologically-confirmed GIST; 64 patients in a training cohort, and 27 patients in a test cohort. FIELD STRENGTH/SEQUENCE T2 -weighted imaging (T2 WI), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced three-dimensional volumetric interpolated breath-hold examination (3D-VIBE) at 1.5T. ASSESSMENT GIST images were manually segmented by two independent radiologists using ITK-SNAP software and MRI features were extracted using Pyradiomics. Two pathologists reviewed the tissue specimens of the tumors to identify the mitotic index and risk classification in consensus. STATISTICAL TESTS The least absolute shrinkage and selection operator (LASSO) regression method was used to select texture features. A logistic regression model was established based on the radiomic score (radscore), tumor location, and maximum diameter to predict tumor classification and develop a nomogram. Receiver operator characteristic (ROC) curves were used to evaluate the ability of the nomogram to distinguish between two tumors with different risk classifications, and a calibration curve was used to evaluate the consistency between the predicted risk and the actual risk. RESULTS The texture signature achieved high efficacy in predicting the mitotic index area under the curve ([AUC], 0.906; 95% confidence interval [CI]: 0.813, 0.961). A nomogram for prediction of the risk classification of GIST, which incorporated this texture signature together with maximum tumor diameter and location, allowed good discrimination in the training cohort (AUC, 0.878; 95% CI: 0.769, 0.960) and the validation cohort (AUC, 0.903; 95% CI: 0.732, 0.922). DATA CONCLUSION The texture-based model can be used to predict GIST mitotic index and risk classification preoperatively. LEVEL OF EVIDENCE 2. TECHNICAL EFFICACY STAGE 3.
Collapse
Affiliation(s)
- Linsha Yang
- Department of Magnetic Resonance Imaging, Qinhuangdao Municipal No. 1 Hospital, Qinhuangdao, China
| | - Tao Zheng
- Department of Magnetic Resonance Imaging, Qinhuangdao Municipal No. 1 Hospital, Qinhuangdao, China
| | - Yanchao Dong
- Department of Intervention, Qinhuangdao Municipal No. 1 Hospital, Qinhuangdao, China
| | - Zhanqiu Wang
- Department of Magnetic Resonance Imaging, Qinhuangdao Municipal No. 1 Hospital, Qinhuangdao, China
| | - Defeng Liu
- Department of Magnetic Resonance Imaging, Qinhuangdao Municipal No. 1 Hospital, Qinhuangdao, China
| | - Juan Du
- Department of Magnetic Resonance Imaging, Qinhuangdao Municipal No. 1 Hospital, Qinhuangdao, China
| | - Shuo Wu
- Department of Magnetic Resonance Imaging, Qinhuangdao Municipal No. 1 Hospital, Qinhuangdao, China
| | - Qinglei Shi
- Scientific Clinical Specialist, Siemens Ltd., Beijing, China
| | - Lanxiang Liu
- Department of Magnetic Resonance Imaging, Qinhuangdao Municipal No. 1 Hospital, Qinhuangdao, China
| |
Collapse
|
38
|
Sim AJ, Frakes JM, Hoffe SE, Wuthrick E, Dilling TJ, Rosenberg S. Novel MR-Guided Radiotherapy Elective Rotation for Radiation Oncology Trainees. Cureus 2020; 12:e10706. [PMID: 33133871 PMCID: PMC7594659 DOI: 10.7759/cureus.10706] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
MR-guided adaptive radiation therapy (RT) is emerging as an integral treatment modality for certain applications and is poised to become an exciting opportunity for greater treatment precision and personalization. However, this is still a relatively nascent technology and only a few institutions and programs have access to this technology for clinical use and trainee education. To increase the diversity of elective offerings and improve the understanding of an MR-guided radiotherapy program, we initiated a unique MR-guided radiotherapy elective rotation for radiation oncology residents. During a representative four-week rotation, 21 simulations were completed by the resident on service. A plurality of simulations were for pancreas stereotactic body radiation therapy (SBRT; 48%) and a majority (71%) of simulations were for adaptive treatments. Additionally, 74 adaptive fractions were completed during this month, of which a significant majority (74%) were for pancreas SBRT. Of the non-adaptive fractions, the majority were for prostate SBRT and intensity-modulated radiation therapy (IMRT). Although many programs may offer training in some aspects of MR-guided radiotherapy as trainees rotate through certain disease sites, we hope this may serve as a blueprint to encourage programs with this technology to fully embrace training in essential competencies related to MR-guided radiotherapy. MR-guided radiotherapy has unique challenges that trainees need to understand to deliver treatment safely: geometric uncertainty, MRI to RT isocenter, and uncertainties with voxel size/tracking.
Collapse
Affiliation(s)
- Austin J Sim
- Radiation Oncology, Moffitt Cancer Center, Tampa, USA
| | | | - Sarah E Hoffe
- Radiation Oncology, Moffitt Cancer Center, Tampa, USA
| | - Evan Wuthrick
- Radiation Oncology, Moffitt Cancer Center, Tampa, USA
| | | | | |
Collapse
|
39
|
Bahrami A, Karimian A, Fatemizadeh E, Arabi H, Zaidi H. A new deep convolutional neural network design with efficient learning capability: Application to CT image synthesis from MRI. Med Phys 2020; 47:5158-5171. [DOI: 10.1002/mp.14418] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 07/03/2020] [Accepted: 07/17/2020] [Indexed: 12/26/2022] Open
Affiliation(s)
- Abass Bahrami
- Faculty of Physics University of Isfahan Isfahan Iran
| | - Alireza Karimian
- Department of Biomedical Engineering Faculty of Engineering University of Isfahan Isfahan Iran
| | - Emad Fatemizadeh
- School of Electrical Engineering Sharif University of Technology Tehran Iran
| | - Hossein Arabi
- Division of Nuclear Medicine and Molecular Imaging Geneva University Hospital GenevaCH‐1211 Switzerland
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging Geneva University Hospital GenevaCH‐1211 Switzerland
- Geneva University NeurocenterGeneva University Geneva1205 Switzerland
- Department of Nuclear Medicine and Molecular Imaging University of GroningenUniversity Medical Center Groningen Groningen Netherlands
- Department of Nuclear Medicine University of Southern Denmark OdenseDK‐500 Denmark
| |
Collapse
|
40
|
Vergalasova I, Cai J. A modern review of the uncertainties in volumetric imaging of respiratory-induced target motion in lung radiotherapy. Med Phys 2020; 47:e988-e1008. [PMID: 32506452 DOI: 10.1002/mp.14312] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 05/15/2020] [Accepted: 05/26/2020] [Indexed: 12/25/2022] Open
Abstract
Radiotherapy has become a critical component for the treatment of all stages and types of lung cancer, often times being the primary gateway to a cure. However, given that radiation can cause harmful side effects depending on how much surrounding healthy tissue is exposed, treatment of the lung can be particularly challenging due to the presence of moving targets. Careful implementation of every step in the radiotherapy process is absolutely integral for attaining optimal clinical outcomes. With the advent and now widespread use of stereotactic body radiation therapy (SBRT), where extremely large doses are delivered, accurate, and precise dose targeting is especially vital to achieve an optimal risk to benefit ratio. This has largely become possible due to the rapid development of image-guided technology. Although imaging is critical to the success of radiotherapy, it can often be plagued with uncertainties due to respiratory-induced target motion. There has and continues to be an immense research effort aimed at acknowledging and addressing these uncertainties to further our abilities to more precisely target radiation treatment. Thus, the goal of this article is to provide a detailed review of the prevailing uncertainties that remain to be investigated across the different imaging modalities, as well as to highlight the more modern solutions to imaging motion and their role in addressing the current challenges.
Collapse
Affiliation(s)
- Irina Vergalasova
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, USA
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong
| |
Collapse
|
41
|
Groot Koerkamp ML, Vasmel JE, Russell NS, Shaitelman SF, Anandadas CN, Currey A, Vesprini D, Keller BM, De-Colle C, Han K, Braunstein LZ, Mahmood F, Lorenzen EL, Philippens MEP, Verkooijen HM, Lagendijk JJW, Houweling AC, van den Bongard HJGD, Kirby AM. Optimizing MR-Guided Radiotherapy for Breast Cancer Patients. Front Oncol 2020; 10:1107. [PMID: 32850318 PMCID: PMC7399349 DOI: 10.3389/fonc.2020.01107] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 06/03/2020] [Indexed: 01/01/2023] Open
Abstract
Current research in radiotherapy (RT) for breast cancer is evaluating neoadjuvant as opposed to adjuvant partial breast irradiation (PBI) with the aim of reducing the volume of breast tissue irradiated and therefore the risk of late treatment-related toxicity. The development of magnetic resonance (MR)-guided RT, including dedicated MR-guided RT systems [hybrid machines combining an MR scanner with a linear accelerator (MR-linac) or 60Co sources], could potentially reduce the irradiated volume even further by improving tumour visibility before and during each RT treatment. In this position paper, we discuss MR guidance in relation to each step of the breast RT planning and treatment pathway, focusing on the application of MR-guided RT to neoadjuvant PBI.
Collapse
Affiliation(s)
| | - Jeanine E. Vasmel
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Nicola S. Russell
- Department of Radiotherapy, The Netherlands Cancer Institute–Antoni van Leeuwenhoek Hospital, Amsterdam, Netherlands
| | - Simona F. Shaitelman
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Carmel N. Anandadas
- Department of Clinical Oncology, The Christie NHS Foundation Trust, Manchester, United Kingdom
| | - Adam Currey
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI, United States
| | - Danny Vesprini
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Brian M. Keller
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Chiara De-Colle
- Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Tübingen, Germany
| | - Kathy Han
- Department of Radiation Oncology, Princess Margaret Cancer Centre, University Health Network, University of Toronto, Toronto, ON, Canada
| | - Lior Z. Braunstein
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | - Faisal Mahmood
- Department of Oncology, Odense University Hospital, Odense, Denmark
- Research Unit for Oncology, Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Ebbe L. Lorenzen
- Department of Oncology, Odense University Hospital, Odense, Denmark
| | | | | | - Jan J. W. Lagendijk
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Antonetta C. Houweling
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands
| | | | - Anna M. Kirby
- Department of Radiotherapy, Royal Marsden NHS Foundation Trust and Institute of Cancer Research, Sutton, United Kingdom
| |
Collapse
|
42
|
Dercle L, Henry T, Carré A, Paragios N, Deutsch E, Robert C. Reinventing radiation therapy with machine learning and imaging bio-markers (radiomics): State-of-the-art, challenges and perspectives. Methods 2020; 188:44-60. [PMID: 32697964 DOI: 10.1016/j.ymeth.2020.07.003] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2020] [Revised: 07/02/2020] [Accepted: 07/06/2020] [Indexed: 12/14/2022] Open
Abstract
Radiation therapy is a pivotal cancer treatment that has significantly progressed over the last decade due to numerous technological breakthroughs. Imaging is now playing a critical role on deployment of the clinical workflow, both for treatment planning and treatment delivery. Machine-learning analysis of predefined features extracted from medical images, i.e. radiomics, has emerged as a promising clinical tool for a wide range of clinical problems addressing drug development, clinical diagnosis, treatment selection and implementation as well as prognosis. Radiomics denotes a paradigm shift redefining medical images as a quantitative asset for data-driven precision medicine. The adoption of machine-learning in a clinical setting and in particular of radiomics features requires the selection of robust, representative and clinically interpretable biomarkers that are properly evaluated on a representative clinical data set. To be clinically relevant, radiomics must not only improve patients' management with great accuracy but also be reproducible and generalizable. Hence, this review explores the existing literature and exposes its potential technical caveats, such as the lack of quality control, standardization, sufficient sample size, type of data collection, and external validation. Based upon the analysis of 165 original research studies based on PET, CT-scan, and MRI, this review provides an overview of new concepts, and hypotheses generating findings that should be validated. In particular, it describes evolving research trends to enhance several clinical tasks such as prognostication, treatment planning, response assessment, prediction of recurrence/relapse, and prediction of toxicity. Perspectives regarding the implementation of an AI-based radiotherapy workflow are presented.
Collapse
Affiliation(s)
- Laurent Dercle
- Department of Radiology, New York Presbyterian Hospital, Columbia University Medical Center, New York, USA
| | - Theophraste Henry
- Molecular Radiotherapy and Innovative Therapeutics, INSERM UMR1030, Gustave Roussy Cancer Campus, Université Paris Saclay, Villejuif, France; Department of Nuclear Medicine and Endocrine Oncology, Gustave Roussy Cancer Campus, Villejuif, France
| | - Alexandre Carré
- Molecular Radiotherapy and Innovative Therapeutics, INSERM UMR1030, Gustave Roussy Cancer Campus, Université Paris Saclay, Villejuif, France; Department of Radiation Oncology, Gustave Roussy Cancer Campus, Villejuif, France
| | | | - Eric Deutsch
- Molecular Radiotherapy and Innovative Therapeutics, INSERM UMR1030, Gustave Roussy Cancer Campus, Université Paris Saclay, Villejuif, France; Department of Radiation Oncology, Gustave Roussy Cancer Campus, Villejuif, France
| | - Charlotte Robert
- Molecular Radiotherapy and Innovative Therapeutics, INSERM UMR1030, Gustave Roussy Cancer Campus, Université Paris Saclay, Villejuif, France; Department of Radiation Oncology, Gustave Roussy Cancer Campus, Villejuif, France.
| |
Collapse
|
43
|
Yudhistiara B, Weber KJ, Huber PE, Ruehle A, Brons S, Haering P, Debus J, Hauswald H. Carbon ion and proton beam irradiation of a normal human TK6 lymphoblastoid cell line within a magnetic field of 1.0 tesla. Cancer Manag Res 2019; 11:8327-8335. [PMID: 31686914 PMCID: PMC6751770 DOI: 10.2147/cmar.s212310] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Accepted: 08/11/2019] [Indexed: 01/04/2023] Open
Abstract
Background Considering the increasing simultaneous application of magnetic resonance imaging (MRI) for more precise photon radiotherapy, it will be likely for particle radiotherapy to adopt MRI for future image guiding. It will then be imperative to evaluate the potential biological effects of a magnetic field (MF) on particle irradiation. This study explores such effects on the highly radiosensitive TK6 lymphoblastoid human cell line. Methods The following three parameters were measured after irradiation with either carbon ion or proton beams using spread out Bragg peaks and applying different doses within a perpendicular 1.0 T MF: (1) cell survival fraction (14 days postirradiation), (2) treatment-specific apoptosis, which was determined through the measurement of population in the sub-G1 phase, and (3) cell cycle progression by means of flow cytometry. These were compared to the same parameters measured without an MF. Results The clonogenic assay in both treatment groups showed almost identical survival curves with overlapping error bars. The calculated α values with and without an MF were 2.18 (σ=0.245) and 2.17 (σ=0.234) for carbon ions and 1.08 (σ=0.138) and 1.13 (σ=0.0679) for protons, respectively. Similarly, the treatment-specific apoptosis and cell cycle progression showed almost identical curves with overlapping error bars. A two-sample, unpooled t-test analysis was implemented for comparison of all mean values and showed p-values >0.05. Conclusion No statistically significant difference in biological response of the TK6 cells was observed when they were irradiated using spreadout Bragg peaks within a perpendicular 1.0 T MF as compared to those, which received the same dose without the MF. This should serve as another supporting piece of evidence toward the implementation of MRI in particle radiotherapy, though further research is necessary.
Collapse
Affiliation(s)
- B Yudhistiara
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg 69120, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - K J Weber
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg 69120, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - P E Huber
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg 69120, Germany.,Clinical Cooperation Unit Molecular Radiation Oncology E055, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - A Ruehle
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg 69120, Germany.,Clinical Cooperation Unit Molecular Radiation Oncology E055, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - S Brons
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg 69120, Germany
| | - P Haering
- Department of Radiation Physics E040, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - J Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg 69120, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg 69120, Germany.,Clinical Cooperation Unit E050, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - H Hauswald
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg 69120, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg 69120, Germany.,Clinical Cooperation Unit E050, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
44
|
Li G, Liu Y, Nie X. Respiratory-Correlated (RC) vs. Time-Resolved (TR) Four-Dimensional Magnetic Resonance Imaging (4DMRI) for Radiotherapy of Thoracic and Abdominal Cancer. Front Oncol 2019; 9:1024. [PMID: 31681573 PMCID: PMC6798178 DOI: 10.3389/fonc.2019.01024] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Accepted: 09/23/2019] [Indexed: 12/25/2022] Open
Abstract
Recent technological and clinical advancements of both respiratory-correlated (RC) and time-resolved (TR) four-dimensional magnetic resonance imaging (4DMRI) techniques are reviewed in light of tumor/organ motion simulation, monitoring, and assessment in radiotherapy. For radiotherapy of thoracic and abdominal cancer, respiratory-induced tumor motion, and motion variation due to breathing irregularities are the major uncertainties in treatment. RC-4DMRI is developed to assess tumor motion for treatment planning, whereas TR-4DMRI is developed to assess both motion and motion variation for treatment planning, delivery and assessment. RC-4DMRI is reconstructed to provide one-breathing-cycle motion, similar to 4D computed tomography (4DCT), the current clinical standard, but with higher soft-tissue contrast, no ionizing radiation, and less binning artifacts due to the use of an internal respiratory surrogate. Recent studies have shown that its spatial resolution has reached or exceeded that of 4DCT and scanning time becomes clinically acceptable. TR-4DMRI is recently developed with an adequate spatiotemporal resolution to assess tumor motion and motion variations for treatment simulation, delivery and assessment. The super-resolution approach is most promising since it can image any organ/body motion, whereas RC-4D MRI are limited to resolve only respiration-induced motion and some TR-4DMRI approaches may more or less depend on RC-4DMRI. TR-4DMRI provides multi-breath motion data that are useful not only in MR-guided radiotherapy but also for building a patient-specific motion model to guide radiotherapy treatment using an non-MR-equipped linear accelerator. Based on 4DMRI motion data, motion-corrected dynamic contrast imaging and diffusion-weighted imaging have also been reported, aiming to facilitate tumor delineation for more accurate radiotherapy targeting. Both RC- and TR-4DMRI have been evaluated for potential clinical applications, such as delineation of tumor volumes, where sufficiently high spatial resolution and large field-of-view are required. The 4DMRI techniques are promising to play a role in motion assessment in radiotherapy treatment planning, delivery, assessment, and adaptation.
Collapse
Affiliation(s)
- Guang Li
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | | | | |
Collapse
|
45
|
Abstract
Modern radiation therapy treatment planning and delivery is a complex process that relies on advanced imaging and computing technology as well as expertise from the medical team. The process begins with simulation imaging, in which three-dimensional computed tomography images (or magnetic resonance images in some cases) are used to characterize the patient anatomy. From there, the radiation oncologist delineates the relevant target/tumor volumes and normal tissue and communicates the goals for treatment planning. The planning process attempts to generate a radiation therapy treatment plan that will deliver a therapeutic dose of radiation to the tumor while sparing nearby normal tissue.
Collapse
|
46
|
Jonsson J, Nyholm T, Söderkvist K. The rationale for MR-only treatment planning for external radiotherapy. Clin Transl Radiat Oncol 2019; 18:60-65. [PMID: 31341977 PMCID: PMC6630106 DOI: 10.1016/j.ctro.2019.03.005] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 03/28/2019] [Accepted: 03/29/2019] [Indexed: 12/12/2022] Open
Abstract
•MR-only treatment planning could improve the spatial accuracy of radiotherapy.•The benefit compared to a mixed MR-CT workflow will vary between patient groups.•Further development of QA tools is needed before the procedure will save resources.
Collapse
Affiliation(s)
| | - Tufve Nyholm
- Department of Radiation Sciences, Umeå University, 90187 Umeå, Sweden
| | | |
Collapse
|
47
|
Godley A, Zheng D, Rong Y. MR-linac is the best modality for lung SBRT. J Appl Clin Med Phys 2019; 20:7-11. [PMID: 31112368 PMCID: PMC6560235 DOI: 10.1002/acm2.12615] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2019] [Revised: 01/05/2019] [Accepted: 01/05/2019] [Indexed: 12/25/2022] Open
Affiliation(s)
- Andrew Godley
- Miami Cancer Institute, Baptist Health South Florida, Miami, FL, USA
| | - Dandan Zheng
- Department of Radiation Oncology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Yi Rong
- Department of Radiation Oncology, University of California Davis Comprehensive Cancer Center, Sacramento, CA, USA
| |
Collapse
|
48
|
Matuszak MM, Kashani R, Green M, Lee C, Cao Y, Owen D, Jolly S, Mierzwa M. Functional Adaptation in Radiation Therapy. Semin Radiat Oncol 2019; 29:236-244. [PMID: 31027641 DOI: 10.1016/j.semradonc.2019.02.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The promise of adaptive therapy to improve outcomes in radiation oncology has been an area of interest and research in the community for many years. One of the sources of data that can be used to drive adaptive therapy is functional information about the tumor or normal tissues. This avenue of adaptation includes many potential sources of data including global markers and functional imaging. Global markers can be assessments derived from blood measurements, patient functional testing, and circulating tumor material and functional imaging data comprises spatial physiological information from various imaging studies such as positron emission tomography, magnetic resonance imaging, and single photon emission computed tomography. The goal of functional adaptation is to use these functional data to adapt radiation therapy to improve patient outcomes. While functional adaptation holds a lot of promise, there are challenges such as quantifying and minimizing uncertainties, streamlining clinical implementation, determining the ideal way to incorporate information within treatment plan optimization, and proving the clinical benefit through trials. This paper will discuss the types of functional information currently being used for adaptation, highlight several areas where functional adaptation has been studied, and introduce some of the barriers to more widespread clinical implementation.
Collapse
Affiliation(s)
- Martha M Matuszak
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI.
| | - Rojano Kashani
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Michael Green
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Choonik Lee
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Yue Cao
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Dawn Owen
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Shruti Jolly
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Michelle Mierzwa
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| |
Collapse
|