1
|
Deng X, He J, Zou Z, Yang X. A model of the spatiotemporal distribution of ozone-squalene reaction and ozonolysis by-products from human body. JOURNAL OF HAZARDOUS MATERIALS 2024; 479:135648. [PMID: 39191011 DOI: 10.1016/j.jhazmat.2024.135648] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Revised: 08/23/2024] [Accepted: 08/23/2024] [Indexed: 08/29/2024]
Abstract
Emissions of ozone and its by-products from ozonolysis on human surfaces lead to indoor air pollution. However, the spatiotemporal distribution of such emissions in indoor environments remains unclear, which may introduce bias when assessing human exposure to ozone and ozonolysis byproducts. This study developed a computational fluid dynamics model to describe the physical and chemical processes involved in the emission of ozone-dependent volatile organic compounds from the human body. The results showed that the reaction probability of ozone in the human body depends on the ozone concentration in the bulk air. For ozone concentrations ranging from 28 ppb to 200 ppb, the reaction probabilities ranged from 5.9 × 10-5 to 1.5 × 10-4. The concentrations of ozone and ozonolysis byproducts obtained from the experimental measurements were used for model validation. The ozonolysis by-products were found to be uniformly distributed in the chamber, whereas the ozone distribution showed less uniformity. The ozone concentration near the human surface was approximately 30 %∼50 % of that in the ambient air. Overall, a model was developed to understand the effect of ozone-surface interactions on indoor air quality. This model can be applied to analyze human exposure to ozone and ozonolysis byproducts and for health risk assessment in built environments.
Collapse
Affiliation(s)
- Xiaorui Deng
- Department of Building Science, Tsinghua University, Beijing, China
| | - Junzhou He
- Department of Power Engineering, North China Electric Power University, Baoding, China.
| | - Ziwei Zou
- Department of Building Science, Tsinghua University, Beijing, China
| | - Xudong Yang
- Department of Building Science, Tsinghua University, Beijing, China.
| |
Collapse
|
2
|
Park S, Won Y, Rim D. Formation and Transport of Secondary Contaminants Associated with Germicidal Ultraviolet Light Systems in an Occupied Classroom. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:12051-12061. [PMID: 38922431 DOI: 10.1021/acs.est.4c00575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/27/2024]
Abstract
Germicidal ultraviolet light (GUV) systems are designed to control airborne pathogen transmission in buildings. However, it is important to acknowledge that certain conditions and system configurations may lead GUV systems to produce air contaminants including oxidants and secondary organic aerosols (SOA). In this study, we modeled the formation and dispersion of oxidants and secondary contaminants generated by the operation of GUV systems employing ultraviolet C 254 and 222 nm. Using a three-dimensional computational fluid dynamics model, we examined the breathing zone concentrations of chemical species in an occupied classroom. Our findings indicate that operating GUV 222 leads to an approximate increase of 10 ppb in O3 concentration and 5.2 μg·m-3 in SOA concentration compared to a condition without GUV operation, while GUV 254 increases the SOA concentration by about 1.2 μg·m-3, with a minimal impact on the O3 concentration. Furthermore, increasing the UV fluence rate of GUV 222 from 1 to 5 μW·cm-2 results in up to 80% increase in the oxidants and SOA concentrations. For GUV 254, elevating the UV fluence rate from 30 to 50 μW·cm-2 or doubling the radiating volume results in up to 50% increase in the SOA concentration. Note that indoor airflow patterns, particularly buoyancy-driven airflow (or displacement ventilation), lead to 15-45% lower SOA concentrations in the breathing zone compared to well-mixed airflow. The results also reveal that when the ventilation rate is below 2 h-1, operating GUV 254 has a smaller impact on human exposure to secondary contaminants than GUV 222. However, GUV 254 may generate more contaminants than GUV 222 when operating at high indoor O3 levels (>15 ppb). These results suggest that the design of GUV systems should consider indoor O3 levels and room ventilation conditions.
Collapse
Affiliation(s)
- Seongjun Park
- Department of Architectural Engineering, Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Youngbo Won
- Department of Architectural Engineering, Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Donghyun Rim
- Department of Architectural Engineering, Pennsylvania State University, University Park, Pennsylvania 16802, United States
| |
Collapse
|
3
|
Besis A, Margaritis D, Samara C, Bekiaris E. Volatile Organic Compounds on Rhodes Island, Greece: Implications for Outdoor and Indoor Human Exposure. TOXICS 2024; 12:486. [PMID: 39058138 PMCID: PMC11280855 DOI: 10.3390/toxics12070486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Revised: 06/13/2024] [Accepted: 06/20/2024] [Indexed: 07/28/2024]
Abstract
Volatile organic compounds (VOC) are considered a class of pollutants with a significant presence in indoor and outdoor air and serious health effects. The aim of this study was to measure and evaluate the levels of outdoor and indoor VOCs at selected sites on Rhodes Island, Greece, during the cold and warm periods of 2023. Spatial and seasonal variations were evaluated; moreover, cancer and non-cancer inhalation risks were assessed. For this purpose, simultaneous indoor-outdoor air sampling was carried out on the island of Rhodes. VOCs were determined by Thermal Desorption-Gas Chromatography/Mass Spectroscopy (TD-GC/MS). Fifty-six VOCs with frequencies ≥ 50% were further considered. VOC concentrations (∑56VOCs) at all sites were found to be higher in the warm period. In the warm and cold sampling periods, the highest concentrations were found at the port of Rhodes City, while total VOC concentrations were dominated by alkanes. The Positive Matrix Factorization (PMF) model was applied to identify the VOC emission sources. Non-cancer and cancer risks for adults were within the safe levels.
Collapse
Affiliation(s)
- Athanasios Besis
- Centre for Research and Technology Hellas (CERTH)/Hellenic Institute of Transport (HIT), GR-57001 Thessaloniki, Greece; (D.M.); (E.B.)
- Environmental Pollution Control Laboratory, Department of Chemistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece;
| | - Dimitrios Margaritis
- Centre for Research and Technology Hellas (CERTH)/Hellenic Institute of Transport (HIT), GR-57001 Thessaloniki, Greece; (D.M.); (E.B.)
| | - Constantini Samara
- Environmental Pollution Control Laboratory, Department of Chemistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece;
| | - Evangelos Bekiaris
- Centre for Research and Technology Hellas (CERTH)/Hellenic Institute of Transport (HIT), GR-57001 Thessaloniki, Greece; (D.M.); (E.B.)
| |
Collapse
|
4
|
Link MF, Robertson RL, Shore A, Hamadani BH, Cecelski CE, Poppendieck DG. Ozone generation and chemistry from 222 nm germicidal ultraviolet light in a fragrant restroom. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2024; 26:1090-1106. [PMID: 38787731 DOI: 10.1039/d4em00144c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2024]
Abstract
Devices using 222 nm germicidal ultraviolet light (GUV222) have been marketed to reduce virus transmission indoors with low risk of occupant harm from direct UV exposure. GUV222 generates ozone, an indoor air pollutant and oxidant, under constrained laboratory conditions, but the chemistry byproducts of GUV222-generated ozone in real indoor spaces is uncharacterized. We deployed GUV222 in a public restroom, with an air change rate of 1 h-1 one weekend and 2 h-1 the next, to measure ozone formation and byproducts generated from ozone chemistry indoors. Ozone from GUV222 increased background concentrations by 5 ppb on average for both weekends and reacted rapidly (e.g., at rates of 3.7 h-1 for the first weekend and 2.0 h-1 for the second) with gas-phase precursors emitted by urinal screens and on surfaces. These ozone reactions generated volatile organic compound and aerosol byproducts (e.g., up to 2.6 μg m-3 of aerosol mass). We find that GUV222 is enhancing indoor chemistry by at least a factor of two for this restroom. The extent of this enhanced chemistry will likely be different for different indoor spaces and is dependent upon ventilation rates, species and concentrations of precursor VOCs, and surface reactivity. Informed by our measurements of ozone reactivity and background aerosol concentrations, we present a framework for predicting aerosol byproduct formation from GUV222 that can be extended to other indoor spaces. Further research is needed to understand how typical uses of GUV222 could impact air quality in chemically diverse indoor spaces and generate indoor air chemistry byproducts that can affect human health.
Collapse
Affiliation(s)
- Michael F Link
- National Institute of Standards and Technology, Gaithersburg, MD, 20899, USA.
| | - Rileigh L Robertson
- National Institute of Standards and Technology, Gaithersburg, MD, 20899, USA.
| | - Andrew Shore
- National Institute of Standards and Technology, Gaithersburg, MD, 20899, USA.
| | - Behrang H Hamadani
- National Institute of Standards and Technology, Gaithersburg, MD, 20899, USA.
| | | | | |
Collapse
|
5
|
Wang N, Müller T, Ernle L, Bekö G, Wargocki P, Williams J. How Does Personal Hygiene Influence Indoor Air Quality? ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:9750-9759. [PMID: 38780915 PMCID: PMC11155237 DOI: 10.1021/acs.est.4c01698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Revised: 05/12/2024] [Accepted: 05/13/2024] [Indexed: 05/25/2024]
Abstract
Humans are known to be a continuous and potent indoor source of volatile organic compounds (VOCs). However, little is known about how personal hygiene, in terms of showering frequency, can influence these emissions and their impact on indoor air chemistry involving ozone. In this study, we characterized the VOC composition of the air in a controlled climate chamber (22.5 m3 with an air change rate at 3.2 h-1) occupied by four male volunteers on successive days under ozone-free (∼0 ppb) and ozone-present (37-40 ppb) conditions. The volunteers either showered the evening prior to the experiments or skipped showering for 24 and 48 h. Reduced shower frequency increased human emissions of gas-phase carboxylic acids, possibly originating from skin bacteria. With ozone present, increasing the number of no-shower days enhanced ozone-skin surface reactions, yielding higher levels of oxidation products. Wearing the same clothing over several days reduced the level of compounds generated from clothing-ozone reactions. When skin lotion was applied, the yield of the skin ozonolysis products decreased, while other compounds increased due to ozone reactions with lotion ingredients. These findings help determine the degree to which personal hygiene choices affect the indoor air composition and indoor air exposures.
Collapse
Affiliation(s)
- Nijing Wang
- Atmospheric
Chemistry Department, Max Planck Institute
for Chemistry, 55128 Mainz, Germany
| | - Tatjana Müller
- Atmospheric
Chemistry Department, Max Planck Institute
for Chemistry, 55128 Mainz, Germany
| | - Lisa Ernle
- Atmospheric
Chemistry Department, Max Planck Institute
for Chemistry, 55128 Mainz, Germany
| | - Gabriel Bekö
- International
Centre for Indoor Environment and Energy, Department of Environmental
and Resource Engineering, Technical University
of Denmark, 2800 Lyngby, Denmark
| | - Pawel Wargocki
- International
Centre for Indoor Environment and Energy, Department of Environmental
and Resource Engineering, Technical University
of Denmark, 2800 Lyngby, Denmark
| | - Jonathan Williams
- Atmospheric
Chemistry Department, Max Planck Institute
for Chemistry, 55128 Mainz, Germany
- Climate
& Atmosphere Research Centre, The Cyprus
Institute, 1645 Nicosia, Cyprus
| |
Collapse
|
6
|
Li L, Zhang W, Liu S, Wang W, Ji X, Zhao Y, Shima M, Yoda Y, Yang D, Huang J, Guo X, Deng F. Cardiorespiratory effects of indoor ozone exposure during sleep and the influencing factors: A prospective study among adults in China. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 924:171561. [PMID: 38458472 DOI: 10.1016/j.scitotenv.2024.171561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 02/16/2024] [Accepted: 03/05/2024] [Indexed: 03/10/2024]
Abstract
Ambient ozone (O3) is recognized as a significant air pollutant with implications for cardiorespiratory health, yet the effects of indoor O3 exposure have received less consideration. Furthermore, while sleep occupies one-third of life, research on the health consequences of O3 exposure during this crucial period is scarce. This study aimed to investigate associations of indoor O3 during sleep with cardiorespiratory function and potential predisposing factors. A prospective study among 81 adults was conducted in Beijing, China. Repeated measurements of cardiorespiratory indices reflecting lung function, airway inflammation, cardiac autonomic function, blood pressure, systemic inflammation, platelet and glucose were performed on each subject. Real-time concentrations of indoor O3 during sleep were monitored. Associations of O3 with cardiorespiratory indices were evaluated using linear mixed-effect model. Effect modification by baseline lifestyles (diet, physical activity, sleep-related factors) and psychological status (stress and depression) were investigated through interaction analysis. The average indoor O3 concentration during sleep was 20.3 μg/m3, which was well below current Chinese indoor air quality standard of 160 μg/m3. O3 was associated with most respiratory indicators of decreased airway function except airway inflammation; whereas the cardiovascular effects were only manifested in autonomic dysfunction and not in others. An interquartile range increases in O3 at 6-h average was associated with changes of -3.60 % (95 % CI: -6.19 %, -0.93 %) and -9.60 % (95 % CI: -14.53 %, -4.39 %) in FVC and FEF25-75, respectively. Further, stronger effects were noted among participants with specific dietary patterns, poorer sleep and higher level of depression. This study provides the first general population-based evidence that low-level exposure to indoor O3 during sleep has greater effects on the respiratory system than on the cardiovascular system. Our findings identify the respiratory system as an important target for indoor O3 exposure, and particularly highlight the need for greater awareness of indoor air quality, especially during sleep.
Collapse
Affiliation(s)
- Luyi Li
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing 100191, China
| | - Wenlou Zhang
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing 100191, China
| | - Shan Liu
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing 100191, China
| | - Wanzhou Wang
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing 100191, China
| | - Xuezhao Ji
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing 100191, China
| | - Yetong Zhao
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing 100191, China
| | - Masayuki Shima
- Department of Public Health, School of Medicine, Hyogo Medical University, Nishinomiya, Hyogo 663-8501, Japan
| | - Yoshiko Yoda
- Department of Public Health, School of Medicine, Hyogo Medical University, Nishinomiya, Hyogo 663-8501, Japan
| | - Di Yang
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing 100191, China
| | - Jing Huang
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing 100191, China
| | - Xinbiao Guo
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing 100191, China
| | - Furong Deng
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing 100191, China; Center for Environment and Health, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China.
| |
Collapse
|
7
|
Silva de Sousa A, de Gois G, da Paz de Souza Paiva RF, Gomes Pimentel LC, de Bodas Terassi PM, Sobral BS, Muniz MA. Impacts of urban emissions and air quality in São Paulo State, Brazil. ENVIRONMENTAL MONITORING AND ASSESSMENT 2024; 196:433. [PMID: 38582822 DOI: 10.1007/s10661-024-12529-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 03/05/2024] [Indexed: 04/08/2024]
Abstract
Daily violations of air quality have an impact on urban populations and cause damage to the environment. Thus, the study evaluated the violations of the daily concentrations of SO2, NO2, and PM10, in regions of the State of São Paulo (SSP), based on the National Environment Council (CONAMA) resolution no 491/2018 and the World Health Organization (WHO - World Health Organization. (2016). Ambient air pollution: a global assessment of exposure and burden of disease.) criteria. Daily SO2, NO2, and PM10data from 6 air quality stations operated by Environmental Company of the State of São Paulo CETESB (1996-2011) were organized and submitted to quality control, with data faults (gaps) being identified. The imputation of data via spline proved satisfactory in filling in the gaps (r > 0.7 and low values of Standard Error of the Estimate (SEE) and Root Mean Square Error (RMSE). The cluster analysis (CA) applied to SO2 formed only one homogeneous group (G1). Contrariwise, NO2 and PM10 formed two homogeneous groups (G1 and G2) each. The stations that showed the greatest similarity according to the CA were Cerqueira Cesar and Osasco. The cophenetic matrix generated for SO2 (0.83), NO2 (0.79), and PM10 (0.77) indicate a satisfactory adjustment of the dendrograms. The exploratory statistics applied to groups G1 and G2 point to the high variability of outliers. The WHO criteria are more restrictive than CONAMA regarding daily violations, with a reduction in SO2 and an increase in specific years for NO2 and PM10. Such variability is due to the adoption of public policies by the SSP and the influence of meteorological systems, being confirmed by the Run test that indicated oscillations in the time series, mainly in PM10, and also recognized well-defined biannual cycles.
Collapse
Affiliation(s)
| | - Givanildo de Gois
- Federal University of Acre (UFAC), Cruzeiro Do Sul, Acre, 69980-000, Brazil
| | | | - Luiz Cláudio Gomes Pimentel
- Department of Meteorology, Geoscience Institute (IGEO), Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Rio de Janeiro, 21941-916, Brazil
| | | | - Bruno Serafini Sobral
- Land and Cartography Institute of Rio de Janeiro (ITERJ), State Secretary of Cities (SECID-RJ), Rio de Janeiro, 20060-060, Brazil
| | | |
Collapse
|
8
|
Ongwandee M, Khianthongkul K, Panyametheekul S, Yongprapat K, Srinaka K, Morris J. Bangkok school indoor air quality: monitoring and intervention by positive pressure fresh air system. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:25454-25467. [PMID: 38472572 DOI: 10.1007/s11356-024-32843-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 02/29/2024] [Indexed: 03/14/2024]
Abstract
A PM2.5 crisis in Thailand has caused the Thai government and public to be increasingly concerned about children's exposure to PM2.5 during time in school. This study is a part of a project to create a modeled effective school indoor air quality management for the Bangkok Metropolitan Administration (BMA). We measured air quality and environment in 10 Bangkok school rooms, including CO2, CO, O3, PM2.5, PM10, TVOCPID, formaldehyde, airborne bacteria and fungi, and gaseous organic contaminants. The indoor-to-outdoor concentration ratios indicated that either outdoor sources or indoor + outdoor sources were the predominant contributors to PM in naturally ventilated classrooms. Meanwhile, PM levels in air-conditioned classrooms strongly depended on class activities. CO2 measurements showed that the air-conditioned classrooms had a low 0.4 per hour air change rate and total fungal counts also reached 800 CFU m-3. Analysis of gaseous organic compounds showed that the two most abundant were aliphatic and aromatic hydrocarbons, accounting for 60% by mass concentration. Interestingly, 2-ethyl-1-hexanol, a mucous membrane irritant, was detected in all study rooms. In one naturally ventilated classroom, we implemented a positive pressure fresh air system to mitigate in-class PM levels; it kept PM levels below 20 μg m-3 throughout the class day. Students reported a 20-37% increase in satisfaction with the perceived indoor environmental quality and reported reduced rates in all symptoms of the sick building syndrome after implementing the positive pressure system.
Collapse
Affiliation(s)
- Maneerat Ongwandee
- Institute of Metropolitan Development, Navamindradhiraj University, Bangkok, Thailand.
- HAUS IAQ Research Unit, Department of Pediatrics, Faculty of Medicine, Chulalongkorn University King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
| | | | - Sirima Panyametheekul
- HAUS IAQ Research Unit, Department of Pediatrics, Faculty of Medicine, Chulalongkorn University King Chulalongkorn Memorial Hospital, Bangkok, Thailand
- Department of Environmental Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
| | - Kamomchai Yongprapat
- Institute of Metropolitan Development, Navamindradhiraj University, Bangkok, Thailand
| | - Kessara Srinaka
- Institute of Metropolitan Development, Navamindradhiraj University, Bangkok, Thailand
| | - John Morris
- School of Industrial Education and Technology, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Thailand
| |
Collapse
|
9
|
Ebrahimifakhar A, Poursadegh M, Hu Y, Yuill DP, Luo Y. A systematic review and meta-analysis of field studies of portable air cleaners: Performance, user behavior, and by-product emissions. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 912:168786. [PMID: 38008326 DOI: 10.1016/j.scitotenv.2023.168786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 11/08/2023] [Accepted: 11/20/2023] [Indexed: 11/28/2023]
Abstract
Indoor air quality is important for the health of building occupants, and public interest in controlling indoor airborne pathogens increased dramatically with the COVID-19 pandemic. Pollutant concentrations can be controlled locally using portable air cleaners (sometimes called air purifiers), which allow occupants to apply air cleaning technology to meet their needs in the location and times that they find appropriate. This paper provides a systematic review of scientific literature that describes field studies of the effectiveness of portable air cleaners. Over 500 papers were considered, and 148 were reviewed in detail, to extract 35 specific research results (e.g., particulate removal performance) or characteristics (e.g., type of building). These were aggregated to provide an overview of results and approaches to this type of research, and to provide meta-analyses of the results. The review includes: descriptions of the geographical location of the research; rate of publications over time; types of buildings and occupants in the field study; types of air cleaner technology being tested; pollutants being measured; resulting pollutant removal effectiveness; patterns of usage and potential barriers to usage by occupants; and the potential for by-product emissions in some air cleaner technologies. An example result is that 83 of the 148 papers measured reductions in fine particulates (PM2.5) and found a mean reduction of 49 % with standard deviation of 20 %. The aggregated results were approximately normally distributed, ranging from finding no significant reduction up to a maximum above 90 % reduction. Sixteen of the 148 papers considered gaseous pollutants, such as volatile organic compounds, nitrogen dioxide, and ozone; 36 papers considered biological pollutants, such as bacteria, viruses, pollen, fungi, etc. An important challenge, common to several studies, is that occupants run the air cleaners for shorter periods and on low airflow rate settings, because of concerns about noise, drafts, and electricity cost, which significantly reduces air cleaning effectiveness.
Collapse
Affiliation(s)
- Amir Ebrahimifakhar
- Delos Labs, Delos, New York, NY 10014, USA; Durham School of Architectural Engineering and Construction, University of Nebraska - Lincoln, 1110 S. 67th Street, Omaha, NE 68182, USA.
| | - Mehrdad Poursadegh
- Durham School of Architectural Engineering and Construction, University of Nebraska - Lincoln, 1110 S. 67th Street, Omaha, NE 68182, USA.
| | - Yifeng Hu
- Durham School of Architectural Engineering and Construction, University of Nebraska - Lincoln, 1110 S. 67th Street, Omaha, NE 68182, USA; Buildings and Transportation Science Division, Oak Ridge National Laboratory, Oak Ridge, TN 37830, USA.
| | - David P Yuill
- Durham School of Architectural Engineering and Construction, University of Nebraska - Lincoln, 1110 S. 67th Street, Omaha, NE 68182, USA.
| | - Yu Luo
- Department of Applied Physics and Applied Mathematics, Columbia University, 500 W. 120th Street, New York, NY 10027, USA.
| |
Collapse
|
10
|
Li X, Yan Y, Fang X, Tu J. Numerical studies of indoor particulate and gaseous micropollutant transport and its impact on human health in densely-occupied spaces. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2024; 342:123031. [PMID: 38036091 DOI: 10.1016/j.envpol.2023.123031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 08/22/2023] [Accepted: 11/21/2023] [Indexed: 12/02/2023]
Abstract
Micropollutants (MPs) have increasingly become a matter of concern owing to potential health risks associated with human inhalation exposure, particularly in densely-occupied indoor environments. This study employed numerical simulations in a traditional built indoor workspace and a public transport cabin to elucidate the transport dynamics and health impacts of particulate and gaseous type of indoor MPs on varying groups of occupants. The risk of infection from pathogen-bearing MPs was evaluated in the workspace using the integrated Eulerian-Lagrangian and modified Wells-Riley model. In the cabin environment, the health impact of inhaled TVOC within the human nasal system was assessed via the integrated nasal-involved manikin model and cancer/non-cancer risk model. The results demonstrated that when ventilation layout was in favour of restricting particulate MPs spread, considerably high health risks (up to 17.22% infection possibility) were generally found in near-fields of emission source (< 2.25 m). Conversely, if the ventilated flow interacts robustly with emission source, every occupant has a minimum 5% infection risk. Incorporating the nasal cavity in the human model offers a nuanced understanding of gaseous MP distributions post-inhalation. Notably, the olfactory and sinus regions displayed heightened vulnerability to TVOC exposure, with a 62.5%-108% concentration increase compared to other nasal areas. Cancer risk assessment plausibly explained the rising occurrence of brain and central nervous system cancer for aircrew members. Non-cancer risk was found acceptable. This study was expected to advance the understanding of environmental pollution and the health risks tied to indoor MPs in densely-populated environments.
Collapse
Affiliation(s)
- Xueren Li
- School of Engineering, RMIT Unversity, PO Box 71, Bundoora, VIC, 3083, Australia
| | - Yihuan Yan
- School of Mechanical and Automotive Engineering, Shanghai University of Engineering Science, Shanghai, 201620, China.
| | - Xiang Fang
- School of Mechanical and Automotive Engineering, Shanghai University of Engineering Science, Shanghai, 201620, China
| | - Jiyuan Tu
- School of Engineering, RMIT Unversity, PO Box 71, Bundoora, VIC, 3083, Australia
| |
Collapse
|
11
|
Barber VP, Goss MB, Franco Deloya LJ, LeMar LN, Li Y, Helstrom E, Canagaratna M, Keutsch FN, Kroll JH. Indoor Air Quality Implications of Germicidal 222 nm Light. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:15990-15998. [PMID: 37827494 PMCID: PMC10607233 DOI: 10.1021/acs.est.3c05680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 09/22/2023] [Accepted: 09/25/2023] [Indexed: 10/14/2023]
Abstract
One strategy for mitigating the indoor transmission of airborne pathogens, including the SARS-CoV-2 virus, is irradiation by germicidal UV light (GUV). A particularly promising approach is 222 nm light from KrCl excimer lamps (GUV222); this inactivates airborne pathogens and is thought to be relatively safe for human skin and eye exposure. However, the impact of GUV222 on the composition of indoor air has received little experimental study. Here, we conduct laboratory experiments in a 150 L Teflon chamber to examine the formation of secondary species by GUV222. We show that GUV222 generates ozone (O3) and hydroxyl radicals (OH), both of which can react with volatile organic compounds to form oxidized volatile organic compounds and secondary organic aerosol particles. Results are consistent with a box model based on the known photochemistry. We use this model to simulate GUV222 irradiation under more realistic indoor air scenarios and demonstrate that under some conditions, GUV222 irradiation can lead to levels of O3, OH, and secondary organic products that are substantially elevated relative to normal indoor conditions. The results suggest that GUV222 should be used at low intensities and in concert with ventilation, decreasing levels of airborne pathogens while mitigating the formation of air pollutants.
Collapse
Affiliation(s)
- Victoria P. Barber
- Department
of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Matthew B. Goss
- Department
of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Lesly J. Franco Deloya
- Department
of Earth, Atmospheric, and Planetary Sciences, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Lexy N. LeMar
- Department
of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, Massachusetts 02139, United States
| | - Yaowei Li
- John
A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138, United States
| | - Erik Helstrom
- Department
of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Manjula Canagaratna
- Center
for Aerosol and Cloud Chemistry, Aerodyne
Research Incorporated, Billerica, Massachusetts 01821, United States
| | - Frank N. Keutsch
- John
A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138, United States
- Department
of Chemistry and Chemical Biology, Harvard
University, Cambridge, Massachusetts 02138, United States
- Department
of Earth and Planetary Sciences, Harvard
University, Cambridge, Massachusetts 02138, United States
| | - Jesse H. Kroll
- Department
of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
- Department
of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, Massachusetts 02139, United States
| |
Collapse
|
12
|
Zhou Z, Crilley LR, Ditto JC, VandenBoer TC, Abbatt JPD. Chemical Fate of Oils on Indoor Surfaces: Ozonolysis and Peroxidation. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:15546-15557. [PMID: 37647222 DOI: 10.1021/acs.est.3c04009] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
Unsaturated triglycerides found in food and skin oils are reactive in ambient air. However, the chemical fate of such compounds has not been well characterized in genuine indoor environments. Here, we monitored the aging of oil coatings on glass surfaces over a range of environmental conditions, using mass spectrometry, nuclear magnetic resonance (NMR), and electron paramagnetic resonance (EPR) techniques. Upon room air exposure (up to 17 ppb ozone), the characteristic ozonolysis products, secondary ozonides, were observed on surfaces near the cooking area of a commercial kitchen, along with condensed-phase aldehydes. In an office setting, ozonolysis is also the dominant degradation pathway for oil films exposed to air. However, for indoor enclosed spaces such as drawers, the depleted air flow makes lipid autoxidation more favorable after an induction period of a few days. Forming hydroperoxides as the major primary products, this radical-mediated peroxidation behavior is accelerated by indoor direct sunlight, but the initiation step in dark settings is still unclear. These results are in accord with radical measurements, indicating that indoor photooxidation facilitates radical formation on surfaces. Overall, many intermediate and end products observed are reactive oxygen species (ROS) that may induce oxidative stress in human bodies. Given that these species can be widely found on both food and household surfaces, their toxicological properties are worth further attention.
Collapse
Affiliation(s)
- Zilin Zhou
- Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
| | - Leigh R Crilley
- Department of Chemistry, York University, Toronto, Ontario M3J 1P3, Canada
| | - Jenna C Ditto
- Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
| | | | - Jonathan P D Abbatt
- Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
| |
Collapse
|
13
|
Weschler CJ, Nazaroff WW. Ozone Loss: A Surrogate for the Indoor Concentration of Ozone-Derived Products. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:13569-13578. [PMID: 37639667 DOI: 10.1021/acs.est.3c03968] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/31/2023]
Abstract
Ozone concentrations tend to be substantially lower indoors than outdoors, largely because of ozone reactions with indoor surfaces. When there are no indoor sources of ozone, a common condition, the net concentration of gaseous products derived from indoor ozone chemistry scales linearly with the difference between outdoor and indoor ozone concentrations, termed "ozone loss." As such, ozone loss is a metric that might be used by epidemiologists to disentangle the adverse health effects of ozone's oxidation products from those of exposure to ozone itself. The present paper examines the characteristics, potential utility, and limitations of the ozone loss concept. We show that for commonly occurring indoor conditions, the ozone loss concentration is directly proportional to the total rate constant for ozone removal on surfaces (ksum) and inversely proportional to the net removal of ozone by air exchange (λ) plus surface reactions (ksum). It follows that the ratio of indoor ozone to ozone loss is equal to the ratio of λ to ksum. Ozone loss is a promising metric for probing potential adverse health effects resulting from exposures to products of indoor ozone chemistry. Notwithstanding its virtues, practitioners using it should be mindful of the limitations discussed in this paper.
Collapse
Affiliation(s)
- Charles J Weschler
- Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, New Jersey 08854, United States
- International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby 2800, Denmark
| | - William W Nazaroff
- Department of Civil and Environmental Engineering, University of California, Berkeley, California 94720-1710, United States
| |
Collapse
|
14
|
Qu Y, Zou Z, Weschler CJ, Liu Y, Yang X. Quantifying Ozone-Dependent Emissions of Volatile Organic Compounds from the Human Body. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:13104-13113. [PMID: 37610659 DOI: 10.1021/acs.est.3c02340] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
Ozone reactions on human body surfaces produce volatile organic compounds (VOCs) that influence indoor air quality. However, the dependence of VOC emissions on the ozone concentration has received limited attention. In this study, we conducted 36 sets of single-person chamber experiments with three volunteers exposed to ozone concentrations ranging from 0 to 32 ppb. Emission fluxes from human body surfaces were measured for 11 targeted skin-oil oxidation products. For the majority of these products, the emission fluxes linearly correlated with ozone concentration, indicating a constant surface yield (moles of VOC emitted per mole of ozone deposited). However, for the second-generation oxidation product 4-oxopentanal, a higher surface yield was observed at higher ozone concentrations. Furthermore, many VOCs have substantial emissions in the absence of ozone. Overall, these results suggest that the complex surface reactions and mass transfer processes involved in ozone-dependent VOC emissions from the human body can be represented using a simplified parametrization based on surface yield and baseline emission flux. Values of these two parameters were quantified for targeted products and estimated for other semiquantified VOC signals, facilitating the inclusion of ozone/skin oil chemistry in indoor air quality models and providing new insights on skin oil chemistry.
Collapse
Affiliation(s)
- Yuekun Qu
- Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, People's Republic of China
| | - Ziwei Zou
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Department of Building Science, Tsinghua University, Beijing 100084, People's Republic of China
| | - Charles J Weschler
- Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, New Jersey 08854, United States
- International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby 2800, Denmark
| | - Yingjun Liu
- Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, People's Republic of China
- Center for Environment and Health, Peking University, Beijing 100871, People's Republic of China
| | - Xudong Yang
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Department of Building Science, Tsinghua University, Beijing 100084, People's Republic of China
| |
Collapse
|
15
|
Bai S, Cui L, Du S, Zhao X, Lin S, Yang X, Zhang J, Liang Y, Wang Z. A life course approach to asthma and wheezing among young children caused by ozone: A prospective birth cohort in northern China. ENVIRONMENTAL RESEARCH 2023; 226:115687. [PMID: 36925033 DOI: 10.1016/j.envres.2023.115687] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 02/22/2023] [Accepted: 03/12/2023] [Indexed: 06/18/2023]
Abstract
BACKGROUND Given differences in vulnerability of children in early life, a life course approach to asthma and wheezing (AW) in young children caused by ozone (O3) is not fully understood. METHODS We conducted a birth cohort in Jinan, China from 2018 to 2021 to elucidate the onset model of childhood AW due to O3 exposure. An inverse distance weighted model was used for individual exposure assessment. The time-dependent Cox proportional-hazard model and logistic model were used to investigate the effects of O3 exposure on AW. Principal component analysis, interaction analysis, and distributed lag model were used to analyze the life course approach. RESULTS The cumulative incidence rate for AW among 6501 children aged 2 was 1.4%. A high level of O3 was related to AW (HR: 2.10, 95% CI: 1.31, 3.37). Only O3 exposure after birth was associated with AW, with an OR of 1.82 (1.08, 3.12), after adjusting for the effect before birth. Furthermore, adjusting for other air pollutants, the HR for the individual effect of high O3 exposure on AW was 2.44 (1.53, 3.89). Interestingly, P values for interactions for O3 and the principal components of other pollutants, as well as the characteristic variable of open windows were less than 0.1. Moreover, an increase in the IQR of O3 exposure at the 31st to 37th weeks before birth and the 1st to 105th weeks after birth was associated with an increase in the HRs for AW. CONCLUSIONS High-level of O3 exposure after birth could lead to AW among young children. Importantly, the AW onset model may include the risk factors accumulation and the sensitive period model. Specifically, there are two sensitive windows in early life, and the correlated insults between the high level of O3 and other pollutants as well as open windows in the asthma-inducing effect.
Collapse
Affiliation(s)
- Shuoxin Bai
- Department of Epidemiology, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, PR China
| | - Liangliang Cui
- Jinan Municipal Center for Disease Control and Prevention, Jinan, Shandong, PR China
| | - Shuang Du
- Department of Occupational and Environmental Health, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, PR China
| | - Xiaodong Zhao
- Jinan Municipal Center for Disease Control and Prevention, Jinan, Shandong, PR China
| | - Shaoqian Lin
- Jinan Municipal Center for Disease Control and Prevention, Jinan, Shandong, PR China
| | - Xiwei Yang
- Department of Occupational and Environmental Health, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, PR China
| | - Jiatao Zhang
- Department of Occupational and Environmental Health, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, PR China
| | - Yuxiu Liang
- Department of Occupational and Environmental Health, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, PR China
| | - Zhiping Wang
- Department of Occupational and Environmental Health, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, PR China.
| |
Collapse
|
16
|
Qin Z, Xu B, Zheng Z, Li L, Zhang G, Li S, Geng C, Bai Z, Yang W. Integrating ambient carbonyl compounds provides insight into the constrained ozone formation chemistry in Zibo city of the North China Plain. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2023; 324:121294. [PMID: 36796669 DOI: 10.1016/j.envpol.2023.121294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 01/25/2023] [Accepted: 02/13/2023] [Indexed: 06/18/2023]
Abstract
Quantifying the impact of carbonyl compounds (carbonyls) on ozone (O3) photochemical formation is crucial to formulating targeted O3 mitigation strategies. To investigate the emission source of ambient carbonyls and their integrated observational constraint on the impact of O3 formation chemistry, a field campaign was conducted in an industrial city (Zibo) of the North China Plain from August to September 2020. The site-to-site variations of OH reactivity for carbonyls were in accordance with the sequence of Beijiao (BJ, urban, 4.4 s-1) > Xindian (XD, suburban, 4.2 s-1) > Tianzhen (TZ, suburban, 1.6 s-1). A 0-D box model (MCMv3.3.1) was applied to assess the O3-precursor relationship influenced by measured carbonyls. It was found that without carbonyls constraint, the O3 photochemical production of the three sites was underestimated to varying degrees, and the biases of overestimating the VOC-limited degree were also identified through a sensitivity test to NOx emission changes, which may be associated with the reactivity of carbonyls. In addition, the results of the positive matrix factorization (PMF) model indicated that the main source of aldehydes and ketones was secondary formation and background (81.6% for aldehydes, 76.8% for ketones), followed by traffic emission (11.0% for aldehydes, 14.0% for ketones). Incorporated with the box model, we found that biogenic emission contributed the most to the O3 production at the three sites, followed by traffic emission as well as industry and solvent usage. Meanwhile, the relative incremental reactivity (RIR) values of O3 precursor groups from diverse VOC emission sources featured consistencies and differences at the three sites, which further highlights the importance of the synergetic mitigation of target O3 precursors at regional and local scales. This study will help to provide targeted policy-guiding O3 control strategies for other regions.
Collapse
Affiliation(s)
- Ze Qin
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China
| | - Bo Xu
- Shandong Zibo Eco-Environmental Monitoring Center, Zibo, 255040, China
| | - Zhensen Zheng
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China
| | - Liming Li
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China
| | - Guotao Zhang
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China
| | - Shijie Li
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China
| | - Chunmei Geng
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China.
| | - Zhipeng Bai
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China
| | - Wen Yang
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China
| |
Collapse
|
17
|
He L, Weschler CJ, Zhang Y, Li F, Bergin MH, Black M, Zhang J(J. Ozone Reaction Products Associated with Biomarkers of Cardiorespiratory Pathophysiology. Am J Respir Crit Care Med 2023; 207:1243-1246. [PMID: 36701642 PMCID: PMC10161747 DOI: 10.1164/rccm.202212-2203le] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Affiliation(s)
- Linchen He
- College of Health, Lehigh University, Bethlehem, Pennsylvania
- Bloomberg School of Public Health, Johns Hopkins University, Baltimore, Maryland
| | - Charles J. Weschler
- Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, New Jersey
- International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby, Denmark
| | - Yinping Zhang
- Department of Building Science, Tsinghua University, Beijing, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| | - Feng Li
- Department of Pulmonary Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | | | - Marilyn Black
- Underwriters Laboratories, Inc., Marietta, Georgia; and
| | - Junfeng (Jim) Zhang
- Nicholas School of the Environment, and
- Duke Global Health Institute, Duke University, Durham, North Carolina
- Duke Kunshan University, Kunshan, China
| |
Collapse
|
18
|
Yu S, Zhang M, Zhu J, Yang X, Bigambo FM, Snijders AM, Wang X, Hu W, Lv W, Xia Y. The effect of ambient ozone exposure on three types of diabetes: a meta-analysis. Environ Health 2023; 22:32. [PMID: 36998068 PMCID: PMC10061724 DOI: 10.1186/s12940-023-00981-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Accepted: 03/13/2023] [Indexed: 06/19/2023]
Abstract
BACKGROUND Ozone as an air pollutant is gradually becoming a threat to people's health. However, the effect of ozone exposure on risk of developing diabetes, a fast-growing global metabolic disease, remains controversial. OBJECTIVE To evaluate the impact of ambient ozone exposure on the incidence rate of type 1, type 2 and gestational diabetes mellitus. METHOD We systematically searched PubMed, Web of Science, and Cochrane Library databases before July 9, 2022, to determine relevant literature. Data were extracted after quality evaluation according to the Newcastle Ottawa Scale (NOS) and the agency for healthcare research and quality (AHRQ) standards, and a meta-analysis was used to evaluate the correlation between ozone exposure and type 1 diabetes mellitus (T1D), type 2 diabetes mellitus (T2D), and gestational diabetes mellitus (GDM). The heterogeneity test, sensitivity analysis, and publication bias were performed using Stata 16.0. RESULTS Our search identified 667 studies from three databases, 19 of which were included in our analysis after removing duplicate and ineligible studies. Among the remaining studies, three were on T1D, five were on T2D, and eleven were on GDM. The result showed that ozone exposure was positively correlated with T2D [effect size (ES) = 1.06, 95% CI: 1.02, 1.11] and GDM [pooled odds ratio (OR) = 1.01, 95% CI: 1.00, 1.03]. Subgroup analysis demonstrated that ozone exposure in the first trimester of pregnancy might raise the risk of GDM. However, no significant association was observed between ozone exposure and T1D. CONCLUSION Long-term exposure to ozone may increase the risk of T2D, and daily ozone exposure during pregnancy was a hazard factor for developing GDM. Decreasing ambient ozone pollution may reduce the burden of both diseases.
Collapse
Affiliation(s)
- Sirui Yu
- State Key Laboratory of Reproductive Medicine, Center for Global Health, Institute of Toxicology, School of Public Health, Nanjing Medical University, No.101 Longmian Road, Nanjing, 211166, China
- Key Laboratory of Modern Toxicology of Ministry of Education, School of Public Health, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Mingzhi Zhang
- State Key Laboratory of Reproductive Medicine, Center for Global Health, Institute of Toxicology, School of Public Health, Nanjing Medical University, No.101 Longmian Road, Nanjing, 211166, China
- Key Laboratory of Modern Toxicology of Ministry of Education, School of Public Health, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Jiamin Zhu
- State Key Laboratory of Reproductive Medicine, Center for Global Health, Institute of Toxicology, School of Public Health, Nanjing Medical University, No.101 Longmian Road, Nanjing, 211166, China
| | - Xu Yang
- State Key Laboratory of Reproductive Medicine, Center for Global Health, Institute of Toxicology, School of Public Health, Nanjing Medical University, No.101 Longmian Road, Nanjing, 211166, China
- Key Laboratory of Modern Toxicology of Ministry of Education, School of Public Health, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Francis Manyori Bigambo
- State Key Laboratory of Reproductive Medicine, Center for Global Health, Institute of Toxicology, School of Public Health, Nanjing Medical University, No.101 Longmian Road, Nanjing, 211166, China
- Key Laboratory of Modern Toxicology of Ministry of Education, School of Public Health, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Antoine M Snijders
- Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, USA
| | - Xu Wang
- Department of Endocrinology, Children's Hospital of Nanjing Medical University, Nanjing, Jiangsu, China
| | - Weiyue Hu
- State Key Laboratory of Reproductive Medicine, Center for Global Health, Institute of Toxicology, School of Public Health, Nanjing Medical University, No.101 Longmian Road, Nanjing, 211166, China.
- Department of Nutrition and Food Safety, School of Public Health, Nanjing Medical University, No.101 Longmian Road, Nanjing, 211166, China.
| | - Wei Lv
- Healthcare Management Program, School of Business, Nanjing University, 22 Hankou Rd, Nanjing, 210093, China.
| | - Yankai Xia
- State Key Laboratory of Reproductive Medicine, Center for Global Health, Institute of Toxicology, School of Public Health, Nanjing Medical University, No.101 Longmian Road, Nanjing, 211166, China.
- Key Laboratory of Modern Toxicology of Ministry of Education, School of Public Health, Nanjing Medical University, Nanjing, Jiangsu, China.
| |
Collapse
|
19
|
Manna SK, Kuilya D, Adhikary A, Maiti A, Mondal S. A minireview of recent developments in ozone detection using optical chemodosimeters. Analyst 2023; 148:954-965. [PMID: 36757270 DOI: 10.1039/d2an01971j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The development of optical chemodosimeters for ozone detection has been an important research subject in recent years because of the environmental and biological relevance of ozone. The design and development of ozone chemodosimeters, as well as their numerous applications from 2009 to 2022, have all been thoroughly covered in this minireview. In this review, chemodosimeters are categorised according to their distinctive reaction mechanism with ozone. The comparative data for each of these chemodosimeters have also been provided here. We have also discussed the difficulties and potential prospects of this fast-evolving discipline. To the best of our knowledge, this is the first review that has comprehensively analysed the progress made in the development of ozone chemodosimeters.
Collapse
Affiliation(s)
- Saikat Kumar Manna
- Department of Chemistry, Haldia Government College, Debhog, Haldia, Purba Medinipur- 721657, West Bengal, India.
| | - Debajyoti Kuilya
- Department of Chemistry, Haldia Government College, Debhog, Haldia, Purba Medinipur- 721657, West Bengal, India.
| | - Ashok Adhikary
- Department of Chemistry, Haldia Government College, Debhog, Haldia, Purba Medinipur- 721657, West Bengal, India.
| | - Aindrila Maiti
- Department of Chemistry, Haldia Government College, Debhog, Haldia, Purba Medinipur- 721657, West Bengal, India.
| | - Sanchita Mondal
- Department of Chemistry, Sree Chaitanya College, Habra, North 24 Parganas, West Bengal-743268, India.
| |
Collapse
|
20
|
Yang DL, Zhang ZN, Liu H, Yang ZY, Liu MM, Zheng QX, Chen W, Xiang P. Indoor air pollution and human ocular diseases: Associated contaminants and underlying pathological mechanisms. CHEMOSPHERE 2023; 311:137037. [PMID: 36349586 DOI: 10.1016/j.chemosphere.2022.137037] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 10/01/2022] [Accepted: 10/25/2022] [Indexed: 06/16/2023]
Abstract
People spend a long time indoors, especially young children. The risk of indoor pollution on human health is one of the current hotspots in environmental and public health. The human ocular surface is highly susceptible to indoor environment quality. Epidemiological data have linked human ophthalmological disorders with exposure to indoor pollution. In this review, we summarized the adverse impacts of indoor pollution on the human ocular surface. Several studies demonstrated that indoor contaminants including particulate matter, volatile/semi-volatile organic compounds, heavy metals, and fuel combustion and cigarette smoke exposure were associated with the incidence of human dry eye, conjunctivitis, glaucoma, cataracts, age-related macular degeneration, and keratitis. In addition, toxicological investigations revealed that indoor pollution-induced induced chronic inflammation, oxidative damage, and disruption of tight junctions are the main underlying pathological mechanisms for ocular surface diseases. Taken together, this review may expand the understanding of pollution-induced eye disorder and highlight the importance of reducing associated contaminants to decrease their detrimental effects on human eyes.
Collapse
Affiliation(s)
- Dan-Lei Yang
- Yunnan Province Innovative Research Team of Environmental Pollution, Food Safety, and Human Health, School of Ecology and Environment, Southwest Forestry University, Kunming, 650224, China
| | - Zhen-Ning Zhang
- Yunnan Province Innovative Research Team of Environmental Pollution, Food Safety, and Human Health, School of Ecology and Environment, Southwest Forestry University, Kunming, 650224, China
| | - Hai Liu
- The Affiliated Hospital of Yunnan University, Eye Hospital of Yunnan Province, Kunming, 650224, China
| | - Zi-Yue Yang
- Yunnan Province Innovative Research Team of Environmental Pollution, Food Safety, and Human Health, School of Ecology and Environment, Southwest Forestry University, Kunming, 650224, China
| | - Mi-Mi Liu
- The Affiliated Ningbo Eye Hospital of Wenzhou Medical University, Ningbo, 315040, China
| | - Qin-Xiang Zheng
- The Affiliated Ningbo Eye Hospital of Wenzhou Medical University, Ningbo, 315040, China
| | - Wei Chen
- The Affiliated Ningbo Eye Hospital of Wenzhou Medical University, Ningbo, 315040, China.
| | - Ping Xiang
- Yunnan Province Innovative Research Team of Environmental Pollution, Food Safety, and Human Health, School of Ecology and Environment, Southwest Forestry University, Kunming, 650224, China.
| |
Collapse
|
21
|
You B, Zhou W, Li J, Li Z, Sun Y. A review of indoor Gaseous organic compounds and human chemical Exposure: Insights from Real-time measurements. ENVIRONMENT INTERNATIONAL 2022; 170:107611. [PMID: 36335895 DOI: 10.1016/j.envint.2022.107611] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Revised: 10/29/2022] [Accepted: 10/31/2022] [Indexed: 06/16/2023]
Abstract
Gaseous organic compounds, mainly volatile organic compounds (VOCs), have become a wide concern in various indoor environments where we spend the majority of our daily time. The sources, compositions, variations, and sinks of indoor VOCs are extremely complex, and their potential impacts on human health are less understood. Owing to the deployment of the state-of-the-art real-time mass spectrometry during the last two decades, our understanding of the sources, dynamic changes and chemical transformations of VOCs indoors has been significantly improved. This review aims to summarize the key findings from mass spectrometry measurements in recent indoor studies including residence, classroom, office, sports center, etc. The sources and sinks, compositions and distributions of indoor VOCs, and the factors (e.g., human activities, air exchange rate, temperature and humidity) driving the changes in indoor VOCs are discussed. The physical and chemical processes of gas-particle partitioning and secondary oxidation processes of VOCs, and their impacts on human health are summarized. Finally, the recommendations for future research directions on indoor VOCs measurements and indoor chemistry are proposed.
Collapse
Affiliation(s)
- Bo You
- State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Wei Zhou
- State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China
| | - Junyao Li
- State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Zhijie Li
- State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yele Sun
- State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China.
| |
Collapse
|
22
|
Fritz H, Tang M, Kinney K, Nagy Z. Evaluating machine learning models to classify occupants' perceptions of their indoor environment and sleep quality from indoor air quality. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2022; 72:1381-1397. [PMID: 35939653 DOI: 10.1080/10962247.2022.2105439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2021] [Revised: 07/06/2022] [Accepted: 07/15/2022] [Indexed: 06/15/2023]
Abstract
A variety of factors can affect a person's perception of their environment and health, but one factor that is often overlooked in indoor settings is the air quality. To address this gap, we develop and evaluate four Machine Learning (ML) models on two disparate datasets using Indoor Air Quality (IAQ) parameters as primary features and components of self-reported IAQ satisfaction and sleep quality as target variables. In each case, we compare models to each other as well as to a simple model that always predicts the majority outcome. In the first analysis, we use open-source data collected from 93 California residences to predict occupant's satisfaction with their indoor environment. Results indicate building ventilation rate, Relative Humidity (RH), and formaldehyde are most influential when predicting IAQ perception and do so with an accuracy greater than the simplified model. The second analysis uses IAQ data gathered from a field study we conducted with 20 participants over 11 weeks to train similar models. We obtain accuracy and F1 scores similar to the simplified model where PM2.5 and TVOCs represent the most important predictors. Our results underscore the ability of IAQ to affect a person's perception of their built environment and health and highlight the utility of ML models to explore the strength of these relationships.Implications: The results from this study show that two outcome variables - occupant's indoor air quality (IAQ) satisfaction and perceived sleep quality - are related to the measured IAQ parameters but not heavily influenced by typical values measured in apartments and homes. This study highlights the ability of machine learning models as exploratory analysis tools to determine underlying relationships within and across datasets in addition to understanding the importance of certain features on the outcome variable. We compare four different models and find that the random forest classifier has the best performance in both analysis on IAQ satisfaction and perceived sleep quality. It is a suitable model for predicting IAQ-related subjective metrics and also provides value insight into the feature importance of the IAQ parameters. The accuracy of any of these machine learning models in predicting occupants' comfort or sleep quality is limited by the dataset size, how data is collected, and range of data. This study identifies the factors that are important to IAQ perception: ventilation rate, relative humidity, and concentrations of formaldehyde, NO2, and particulate matter. It indicates that sensors that can measure these variables are necessary for future, related studies that model occupants' IAQ satisfaction. However, this study does not find strong relationships between any of the IAQ parameters measured in this study and perceived sleep quality despite the logical pathway between these many pollutants and respiratory issues. A prediction model of IAQ perception or sleep quality can be integrated into home management systems to automatically adjust building operations such as ventilation rates in smart buildings. Once buildings are equipped with a network of low-cost sensors that measure concentrations of pollutants and operating conditions of the ventilation system, the prediction model can be used to predict the occupants' comfort and facilitate the control of the ventilation system.
Collapse
Affiliation(s)
- Hagen Fritz
- Department of Civil, Architectural and Environmental Engineering, University of Texas at Austin, Austin, Texas, USA
| | - Mengjia Tang
- Department of Civil, Architectural and Environmental Engineering, University of Texas at Austin, Austin, Texas, USA
| | - Kerry Kinney
- Department of Civil, Architectural and Environmental Engineering, University of Texas at Austin, Austin, Texas, USA
| | - Zoltan Nagy
- Department of Civil, Architectural and Environmental Engineering, University of Texas at Austin, Austin, Texas, USA
| |
Collapse
|
23
|
Mansouri A, Wei W, Alessandrini JM, Mandin C, Blondeau P. Impact of Climate Change on Indoor Air Quality: A Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph192315616. [PMID: 36497689 PMCID: PMC9740977 DOI: 10.3390/ijerph192315616] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 11/18/2022] [Accepted: 11/20/2022] [Indexed: 05/28/2023]
Abstract
Climate change can affect the indoor environment due to heat and mass transfers between indoor and outdoor environments. To mitigate climate change impacts and adapt buildings to the changing environment, changes in building characteristics and occupants' behavior may occur. To characterize the effects of climate change on indoor air quality (IAQ), the present review focused on four aspects: (1) experimental and modeling studies that relate IAQ to future environmental conditions, (2) evolution of indoor and outdoor air concentrations in the coming years with regard to temperature rise, (3) climate change mitigation and adaptation actions in the building sector, and (4) evolution of human behavior in the context of climate change. In the indoor environment, experimental and modeling studies on indoor air pollutants highlighted a combined effect of temperature and relative humidity on pollutant emissions from indoor sources. Five IAQ models developed for future climate data were identified in the literature. In the outdoor environment, the increasing ambient temperature may lead directly or indirectly to changes in ozone, particle, nitrogen oxides, and volatile organic compound concentrations in some regions of the world depending on the assumptions made about temperature evolution, anthropogenic emissions, and regional regulation. Infiltration into buildings of outdoor air pollutants is governed by many factors, including temperature difference between indoors and outdoors, and might increase in the years to come during summer and decrease during other seasons. On the other hand, building codes in some countries require a higher airtightness for new and retrofitted buildings. The building adaptation actions include the reinforcement of insulation, implementation of new materials and smart building technologies, and a more systematic and possibly longer use of air conditioning systems in summer compared to nowadays. Moreover, warmer winters, springs, and autumns may induce an increasing duration of open windows in these seasons, while the use of air conditioning in summer may reduce the duration of open windows.
Collapse
Affiliation(s)
- Aya Mansouri
- Scientific and Technical Centre for Building (CSTB), Health and Comfort Department, 84 Avenue Jean Jaurès, 77447 Marne-la-Vallée, France
- Laboratoire des Sciences de l’Ingénieur pour l’Environnement (LaSIE), UMR CNRS 7356, La Rochelle University, 17042 La Rochelle, France
| | - Wenjuan Wei
- Scientific and Technical Centre for Building (CSTB), Health and Comfort Department, 84 Avenue Jean Jaurès, 77447 Marne-la-Vallée, France
| | - Jean-Marie Alessandrini
- Scientific and Technical Centre for Building (CSTB), Health and Comfort Department, 84 Avenue Jean Jaurès, 77447 Marne-la-Vallée, France
| | - Corinne Mandin
- Scientific and Technical Centre for Building (CSTB), Health and Comfort Department, 84 Avenue Jean Jaurès, 77447 Marne-la-Vallée, France
| | - Patrice Blondeau
- Laboratoire des Sciences de l’Ingénieur pour l’Environnement (LaSIE), UMR CNRS 7356, La Rochelle University, 17042 La Rochelle, France
| |
Collapse
|
24
|
Butman JL, Thomson RJ, Geiger FM. Unanticipated Hydrophobicity Increases of Squalene and Human Skin Oil Films Upon Ozone Exposure. J Phys Chem B 2022; 126:9417-9423. [PMID: 36331532 DOI: 10.1021/acs.jpcb.2c04849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The C-H and O-H oscillators on the surfaces of thin films of human-derived skin oil and squalene are probed under ambient conditions (300 K, 1 atm total pressure, 40% RH) using second-order vibrational spectroscopy and contact angle goniometry before and after exposure to ppb amounts of ozone. Skin oil and squalene are found to produce different vibrational sum frequency generation spectra in the C-H stretching region, while exposure to ozone results in surface spectra for both materials that is consistent with a loss of C-H oscillators. The measured contact angles show that the hydrophobicity of the films increases following exposure to ozone, consistent with the reduction in C═C···H2O ("πH") bonding interactions that is expected from C═C double bond loss due to ozonolysis and indicating that the polar functional groups formed point toward the films' interiors. Implications for heterogeneous indoor chemistry are discussed.
Collapse
Affiliation(s)
- Jana L Butman
- Department of Chemistry, Northwestern University, Evanston, Illinois 60208, United States
| | - Regan J Thomson
- Department of Chemistry, Northwestern University, Evanston, Illinois 60208, United States
| | - Franz M Geiger
- Department of Chemistry, Northwestern University, Evanston, Illinois 60208, United States
| |
Collapse
|
25
|
Pytel K, Marcinkowska R, Rutkowska M, Zabiegała B. Recent advances on SOA formation in indoor air, fate and strategies for SOA characterization in indoor air - A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 843:156948. [PMID: 35753459 DOI: 10.1016/j.scitotenv.2022.156948] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 06/18/2022] [Accepted: 06/20/2022] [Indexed: 06/15/2023]
Abstract
Recent studies proves that indoor air chemistry differs in many aspects from atmospheric one. People send up to 90 % of their life indoors being exposed to pollutants present in gas, particle and solid phase. Particle phase indoor is composed of particles emitted from various sources, among which there is an indoor source - secondary chemical reactions leading to formation of secondary organic aerosol (SOA). Lately, researchers' attentions turned towards the ultrafine particles, for there are still a lot of gaps in knowledge concerning this field of study, while there is evidence of negative influence of ultrafine particles on human health. Presented review sums up current knowledge about secondary particle formation in indoor environment and development of analytical techniques applied to study those processes. The biggest concern today is studying ROS, for their lifetime in indoor air is very short due to reactions at the very beginning of terpene oxidation process. Another interesting aspect that is recently discovered is monoterpene autooxidation process that leads to HOMs formation that in turn can influence SOA formation yield. A complex studies covering gas phase and particle phase characterization, but also toxicological studies are crucial to fully understand indoor air chemistry leading to ultrafine particle formation.
Collapse
Affiliation(s)
- Klaudia Pytel
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, 11/12 Narutowicza Str., 80-233 Gdańnsk, Poland
| | - Renata Marcinkowska
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, 11/12 Narutowicza Str., 80-233 Gdańnsk, Poland
| | - Małgorzata Rutkowska
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, 11/12 Narutowicza Str., 80-233 Gdańnsk, Poland
| | - Bożena Zabiegała
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, 11/12 Narutowicza Str., 80-233 Gdańnsk, Poland.
| |
Collapse
|
26
|
Zannoni N, Lakey PSJ, Won Y, Shiraiwa M, Rim D, Weschler CJ, Wang N, Ernle L, Li M, Bekö G, Wargocki P, Williams J. The human oxidation field. Science 2022; 377:1071-1077. [PMID: 36048928 DOI: 10.1126/science.abn0340] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Hydroxyl (OH) radicals are highly reactive species that can oxidize most pollutant gases. In this study, high concentrations of OH radicals were found when people were exposed to ozone in a climate-controlled chamber. OH concentrations calculated by two methods using measurements of total OH reactivity, speciated alkenes, and oxidation products were consistent with those obtained from a chemically explicit model. Key to establishing this human-induced oxidation field is 6-methyl-5-hepten-2-one (6-MHO), which forms when ozone reacts with the skin-oil squalene and subsequently generates OH efficiently through gas-phase reaction with ozone. A dynamic model was used to show the spatial extent of the human-generated OH oxidation field and its dependency on ozone influx through ventilation. This finding has implications for the oxidation, lifetime, and perception of chemicals indoors and, ultimately, human health.
Collapse
Affiliation(s)
- Nora Zannoni
- Atmospheric Chemistry Department, Max Planck Institute for Chemistry, Mainz, Germany
| | | | - Youngbo Won
- Department of Architectural Engineering, Pennsylvania State University, University Park, PA, USA
| | - Manabu Shiraiwa
- Department of Chemistry, University of California, Irvine, CA, USA
| | - Donghyun Rim
- Department of Architectural Engineering, Pennsylvania State University, University Park, PA, USA
| | - Charles J Weschler
- International Centre for Indoor Environment and Energy, Environmental and Resource Engineering, DTU Sustain, Technical University of Denmark, Lyngby, Denmark.,Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, NJ, USA
| | - Nijing Wang
- Atmospheric Chemistry Department, Max Planck Institute for Chemistry, Mainz, Germany
| | - Lisa Ernle
- Atmospheric Chemistry Department, Max Planck Institute for Chemistry, Mainz, Germany
| | - Mengze Li
- Atmospheric Chemistry Department, Max Planck Institute for Chemistry, Mainz, Germany
| | - Gabriel Bekö
- International Centre for Indoor Environment and Energy, Environmental and Resource Engineering, DTU Sustain, Technical University of Denmark, Lyngby, Denmark
| | - Pawel Wargocki
- International Centre for Indoor Environment and Energy, Environmental and Resource Engineering, DTU Sustain, Technical University of Denmark, Lyngby, Denmark
| | - Jonathan Williams
- Atmospheric Chemistry Department, Max Planck Institute for Chemistry, Mainz, Germany.,Energy, Environment and Water Research Center, The Cyprus Institute, Nicosia, Cyprus
| |
Collapse
|
27
|
Bhat MA, Eraslan FN, Awad A, Malkoç S, Üzmez ÖÖ, Döğeroğlu T, Gaga EO. Investigation of indoor and outdoor air quality in a university campus during COVID-19 lock down period. BUILDING AND ENVIRONMENT 2022; 219:109176. [PMID: 35599669 PMCID: PMC9116033 DOI: 10.1016/j.buildenv.2022.109176] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 04/25/2022] [Accepted: 05/05/2022] [Indexed: 06/15/2023]
Abstract
The pandemic of COVID-19 currently shadows the world; the whole earth has been on an unprecedented lockdown. Social distancing among people interrupted domestic and international air traffic, suspended industrial productions and economic activities, and had various far-reaching and undetermined implications on air quality. Improvement in air quality has been reported in many cities during the lockdown. On March 22, 2020, the Turkish government enforced strict lockdown measures to reduce coronavirus disease transmission. This lockdown had a significant impact on the movement of people within the country, which resulted in a major drop in worldwide commercial activities. During this period, university campuses were emptied due to the transition to distance education. In this study, various air pollutants sulfur dioxide (SO2), nitrogen dioxide (NO2), ozone (O3), fine particulate matter (PM2.5), total bacteria, and total fungi were measured in different indoor environments at Eskişehir Technical University Campus in Eskişehir, Turkey during COVID-19 lock down period. Also, to calculate the indoor and outdoor ratios (I/O) of the pollutants, simultaneous outdoor measurements were also carried out. The average indoor SO2, NO2, O3, and PM2.5 concentrations in different indoor environments ranged between 2.10 and 54.58, 1.36-30.89, 12.01-39.05, and 21-94 μg/m3, respectively. The total number of bacteria and fungi ranged between 21.83-514.15 and 13.10-83.36 CFU/m3, respectively. Our study intends to give a glimpse to quantify the impact of a pandemic on air quality in different indoor environments in a university campus in Eskişehir, Turkey and calls for follow-up studies. Indoor concentrations were evaluated together with outdoor concentrations. In general, it can be said that the calculated I/O ratios for SO2, NO2, O3, bacteria, and fungi were less than 1 in most indoor environments.
Collapse
Affiliation(s)
- Mansoor Ahmad Bhat
- Eskişehir Technical University, Faculty of Engineering, Department of Environmental Engineering, 26555, Eskişehir, Turkey
| | - Fatma Nur Eraslan
- Eskişehir Technical University, Faculty of Engineering, Department of Environmental Engineering, 26555, Eskişehir, Turkey
| | - Alaa Awad
- Eskişehir Technical University, Faculty of Engineering, Department of Environmental Engineering, 26555, Eskişehir, Turkey
| | - Semra Malkoç
- Eskişehir Technical University, Faculty of Engineering, Department of Environmental Engineering, 26555, Eskişehir, Turkey
- Eskişehir Technical University, Environmental Research Center (ÇEVMER), 26555, Eskişehir, Turkey
| | - Özlem Özden Üzmez
- Eskişehir Technical University, Faculty of Engineering, Department of Environmental Engineering, 26555, Eskişehir, Turkey
| | - Tuncay Döğeroğlu
- Eskişehir Technical University, Faculty of Engineering, Department of Environmental Engineering, 26555, Eskişehir, Turkey
| | - Eftade O Gaga
- Eskişehir Technical University, Faculty of Engineering, Department of Environmental Engineering, 26555, Eskişehir, Turkey
- Eskişehir Technical University, Environmental Research Center (ÇEVMER), 26555, Eskişehir, Turkey
| |
Collapse
|
28
|
Ilacqua V, Scharko N, Zambrana J, Malashock D. Survey of residential indoor particulate matter measurements 1990-2019. INDOOR AIR 2022; 32:e13057. [PMID: 35904386 PMCID: PMC10499005 DOI: 10.1111/ina.13057] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 05/03/2022] [Accepted: 05/06/2022] [Indexed: 06/15/2023]
Abstract
We surveyed literature on measurements of indoor particulate matter in all size fractions, in residential environments free of solid fuel combustion (other than wood for recreation or space heating). Data from worldwide studies from 1990 to 2019 were assembled into the most comprehensive collection to date. Out of 2752 publications retrieved, 538 articles from 433 research projects met inclusion criteria and reported unique data, from which more than 2000 unique sets of indoor PM measurements were collected. Distributions of mean concentrations were compiled, weighted by study size. Long-term trends, the impact of non-smoking, air cleaners, and the influence of outdoor PM were also evaluated. Similar patterns of indoor PM distributions for North America and Europe could reflect similarities in the indoor environments of these regions. Greater observed variability for all regions of Asia may reflect greater heterogeneity in indoor conditions, but also low numbers of studies for some regions. Indoor PM concentrations of all size fractions were mostly stable over the survey period, with the exception of observed declines in PM2.5 in European and North American studies, and in PM10 in North America. While outdoor concentrations were correlated with indoor concentrations across studies, indoor concentrations had higher variability, illustrating a limitation of using outdoor measurements to approximate indoor PM exposures.
Collapse
Affiliation(s)
- Vito Ilacqua
- Indoor Environments Division, United States Environmental Protection Agency, Washington, District of Columbia, USA
| | - Nicole Scharko
- American Association for the Advancement of Science (AAAS) - Science, Technology, and Policy Fellow, Washington, District of Columbia, USA
| | - Jordan Zambrana
- Indoor Environments Division, United States Environmental Protection Agency, Washington, District of Columbia, USA
| | - Daniel Malashock
- Indoor Environments Division, United States Environmental Protection Agency, Washington, District of Columbia, USA
| |
Collapse
|
29
|
Integration of Indoor Air Quality Prediction into Healthy Building Design. SUSTAINABILITY 2022. [DOI: 10.3390/su14137890] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Healthy building design is an emerging field of architecture and building engineering. Indoor air quality (IAQ) is an inevitable factor that should be considered in healthy building design due to its demonstrated links with human health and well-being. This paper proposes to integrate IAQ prediction into healthy building design by developing a simulation toolbox, termed i-IAQ, using MATLAB App Designer. Within the i-IAQ, users can input information of building layout and wall-openings and select air pollutant sources from the database. As an output, the toolbox simulates indoor levels of carbon dioxide (CO2), total volatile organic compounds (TVOC), inhalable particles (PM10), fine particles (PM2.5), nitrogen dioxide (NO2), and ozone (O3) during the occupied periods. Based on the simulation results, the toolbox also offers diagnosis and recommendations to improve the design. The accuracy of the toolbox was validated by a case study in an apartment where physical measurements of air pollutants took place. The results suggest that designers can integrate the i-IAQ toolbox in building design, so that the potential IAQ issues can be resolved at the early design stage at a low cost. The paper outcomes have the potential to pave a way towards more holistic healthy building design, and novel and cost-effective IAQ management.
Collapse
|
30
|
Pei G, Xuan Y, Morrison G, Rim D. Understanding Ozone Transport and Deposition within Indoor Surface Boundary Layers. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:7820-7829. [PMID: 35670501 DOI: 10.1021/acs.est.1c08040] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Ozone-initiated oxidation reactions on indoor surfaces meaningfully alter the chemical composition of indoor air and human exposure to air toxins. Ozone mass transport within the indoor surface boundary layer plays a key role in ozone-surface reaction kinetics. However, limited information is available on detailed ozone transport dynamics near realistic, irregular indoor surfaces. This paper presents a research framework to study the underlying mechanisms of ozone reactions with realistic indoor surfaces based on microscope scanning of surface material and detailed Computational Fluid Dynamics (CFD) simulation. The study results show that indoor surface topography can meaningfully affect ozone mass transport within a surface boundary layer, thereby modulating near-surface ozone concentration gradient and surface uptake. The results also reveal that the effective indoor surface area available for ozone reaction varies with indoor air speed and turbulent air mixing within the boundary layer. The detailed dynamic behaviors of ozone reactions with realistic indoor surfaces provide insights into the implications of pollutant-surface interactions on indoor chemistry and air quality.
Collapse
Affiliation(s)
- Gen Pei
- Department of Architectural Engineering, Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Yuan Xuan
- Department of Mechanical Engineering, Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Glenn Morrison
- Department of Environmental Sciences and Engineering, Gillings School of Global Public Health, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| | - Donghyun Rim
- Department of Architectural Engineering, Pennsylvania State University, University Park, Pennsylvania 16802, United States
| |
Collapse
|
31
|
Coffaro B, Weisel CP. Reactions and Products of Squalene and Ozone: A Review. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:7396-7411. [PMID: 35648815 PMCID: PMC9231367 DOI: 10.1021/acs.est.1c07611] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 05/13/2022] [Accepted: 05/13/2022] [Indexed: 05/15/2023]
Abstract
This critical review describes the squalene-ozone (SqOz) reaction, or squalene ozonolysis. Ambient ozone penetrates indoors and drives indoor air chemistry. Squalene, a component of human skin oil, contains six carbon-carbon double bonds and is very reactive with ozone. Bioeffluents from people contribute to indoor air chemistry and affect the indoor air quality, resulting in exposures because people spend the majority of their time indoors. The SqOz reaction proceeds through various formation pathways and produces compounds that include aldehydes, ketones, carboxylic acids, and dicarbonyl species, which have a range of volatilities. In this critical review of SqOz chemistry, information on the mechanism of reaction, reaction probability, rate constants, and reaction kinetics are compiled. Characterizations of SqOz reaction products have been done in laboratory experiments and real-world settings. The effect of multiple environmental parameters (ozone concentration, air exchange rate (AER), temperature, and relative humidity (RH)) in indoor settings are summarized. This critical review concludes by identifying the paucity of available exposure, health, and toxicological data for known reaction products. Key knowledge gaps about SqOz reactions leading to indoor exposures and adverse health outcomes are provided as well as an outlook on where the field is headed.
Collapse
Affiliation(s)
- Breann Coffaro
- Environmental
and Health Sciences Institute and Graduate Program in Exposure Science, Rutgers, The State University of New Jersey, Piscataway Township, New
Jersey 08854, United
States
| | - Clifford P. Weisel
- Environmental
and Health Sciences Institute and School of Public Health, Rutgers, The State University of New Jersey, Piscataway Township, New
Jersey 08854, United
States
| |
Collapse
|
32
|
Zhou Z, Lakey PSJ, von Domaros M, Wise N, Tobias DJ, Shiraiwa M, Abbatt JPD. Multiphase Ozonolysis of Oleic Acid-Based Lipids: Quantitation of Major Products and Kinetic Multilayer Modeling. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:7716-7728. [PMID: 35671499 DOI: 10.1021/acs.est.2c01163] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Commonly found in atmospheric aerosols, cooking oils, and human sebum, unsaturated lipids rapidly decay upon exposure to ozone, following the Criegee mechanism. Here, the gas-surface ozonolysis of three oleic acid-based compounds was studied in a reactor and indoors. Under dry conditions, quantitative product analyses by 1H NMR indicate up to 79% molar yield of stable secondary ozonides (SOZs) in oxidized triolein and methyl oleate coatings. Elevated relative humidity (RH) significantly suppresses the SOZ yields, enhancing the formation of condensed-phase aldehydes and volatile C9 products. Along with kinetic parameters informed by molecular dynamics simulations, these results were used as constraints in a kinetic multilayer model (KM-GAP) simulating triolein ozonolysis. Covering a wide range of coating thicknesses and ozone levels, the model predicts a much faster decay near the gas-lipid interface compared to the bulk. Although the dependence of RH on SOZ yields is well predicted, the model overestimates the production of H2O2 and aldehydes. With negligible dependence on RH, the product composition for oxidized oleic acid is substantially affected by a competitive reaction between Criegee intermediates (CIs) and carboxylic acids. The resulting α-acyloxyalkyl hydroperoxides (α-AAHPs) have much higher molar yields (29-38%) than SOZs (12-16%). Overall, the ozone-lipid chemistry could affect the indoor environment through "crust" accumulation on surfaces and volatile organic compound (VOC) emission. In the atmosphere, the peroxide formation and changes in particle hygroscopicity may have effects on climate. The related health impacts are also discussed.
Collapse
Affiliation(s)
- Zilin Zhou
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6, Canada
| | - Pascale S J Lakey
- Department of Chemistry, University of California, Irvine, California 92697-2025, United States
| | - Michael von Domaros
- Department of Chemistry, University of California, Irvine, California 92697-2025, United States
| | - Natsuko Wise
- Department of Chemistry, University of California, Irvine, California 92697-2025, United States
| | - Douglas J Tobias
- Department of Chemistry, University of California, Irvine, California 92697-2025, United States
| | - Manabu Shiraiwa
- Department of Chemistry, University of California, Irvine, California 92697-2025, United States
| | - Jonathan P D Abbatt
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6, Canada
| |
Collapse
|
33
|
Wang N, Ernle L, Bekö G, Wargocki P, Williams J. Emission Rates of Volatile Organic Compounds from Humans. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:4838-4848. [PMID: 35389619 PMCID: PMC9022422 DOI: 10.1021/acs.est.1c08764] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 03/25/2022] [Accepted: 03/28/2022] [Indexed: 05/30/2023]
Abstract
Human-emitted volatile organic compounds (VOCs) are mainly from breath and the skin. In this study, we continuously measured VOCs in a stainless-steel environmentally controlled climate chamber (22.5 m3, air change rate at 3.2 h-1) occupied by four seated human volunteers using proton transfer reaction time-of-flight mass spectrometry and gas chromatography mass spectrometry. Experiments with human whole body, breath-only, and dermal-only emissions were performed under ozone-free and ozone-present conditions. In addition, the effect of temperature, relative humidity, clothing type, and age was investigated for whole-body emissions. Without ozone, the whole-body total emission rate (ER) was 2180 ± 620 μg h-1 per person (p-1), dominated by exhaled chemicals. The ERs of oxygenated VOCs were positively correlated with the enthalpy of the air. Under ozone-present conditions (∼37 ppb), the whole-body total ER doubled, with the increase mainly driven by VOCs resulting from skin surface lipids/ozone reactions, which increased with relative humidity. Long clothing (more covered skin) was found to reduce the total ERs but enhanced certain chemicals related to the clothing. The ERs of VOCs derived from this study provide a valuable data set of human emissions under various conditions and can be used in models to better predict indoor air quality, especially for highly occupied environments.
Collapse
Affiliation(s)
- Nijing Wang
- Atmospheric
Chemistry Department, Max Planck Institute
for Chemistry, Hahn-Meitner-Weg 1, 55128 Mainz, Germany
| | - Lisa Ernle
- Atmospheric
Chemistry Department, Max Planck Institute
for Chemistry, Hahn-Meitner-Weg 1, 55128 Mainz, Germany
| | - Gabriel Bekö
- International
Centre for Indoor Environment and Energy, Department of Environmental
and Resource Engineering, Technical University
of Denmark, Nils Koppels Alle 402, 2800 Lyngby, Denmark
| | - Pawel Wargocki
- International
Centre for Indoor Environment and Energy, Department of Environmental
and Resource Engineering, Technical University
of Denmark, Nils Koppels Alle 402, 2800 Lyngby, Denmark
| | - Jonathan Williams
- Atmospheric
Chemistry Department, Max Planck Institute
for Chemistry, Hahn-Meitner-Weg 1, 55128 Mainz, Germany
- Climate
& Atmosphere Research Centre, The Cyprus
Institute, 1645 Nicosia, Cyprus
| |
Collapse
|
34
|
Larsson L, Mattsson J. Achieving a healthy indoor environment by using an emissions barrier to stop the spread of chemicals from a building into the indoor air. UCL OPEN ENVIRONMENT 2022; 4:e033. [PMID: 37228462 PMCID: PMC10171402 DOI: 10.14324/111.444/ucloe.000033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 01/20/2022] [Indexed: 05/27/2023]
Abstract
An emissions barrier was used in a premises due to complaints about the indoor air quality (IAQ) as a result of emissions from the building in question. The emissions comprised chlorophenols/chloroanisoles and polycyclic aromatic hydrocarbons (PAH) from treated wood and volatile organic compounds (VOCs), mainly 2-ethylhexanol, from polyvinyl chloride (PVC) flooring and the glue used to paste the flooring onto a concrete slab. Attaching the barrier at the surfaces from where the emissions were spread (floor, walls, ceilings) resulted in a fresh and odour-free indoor air. We conclude that using an emissions barrier in buildings made unhealthy by moisture is an efficient way of restoring pleasant and healthy indoor air.
Collapse
Affiliation(s)
| | - Johan Mattsson
- cTrap AB, Råbylunds Gård, Prästavägen 12, 224 80 Lund, Sweden
| |
Collapse
|
35
|
Wang Y, Wang K, Cheng W, Zhang Y. Global burden of chronic obstructive pulmonary disease attributable to ambient ozone in 204 countries and territories during 1990-2019. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:9293-9305. [PMID: 34505240 DOI: 10.1007/s11356-021-16233-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 08/25/2021] [Indexed: 06/13/2023]
Abstract
Ambient ozone becomes one of significant environmental threats to chronic obstructive pulmonary disease (COPD) in recent decades. To date, however, few systematic analyses have been performed to quantify ozone-attributable disease burden, globally and regionally. In this study, we aimed to comprehensively depict the global trend of ozone-related COPD premature deaths and disability-adjusted life years (DALYs). We derived estimates of COPD burden attributable to ambient ozone for 204 countries and territories during 1990-2019 from the Global Burden of Disease Study 2019. We examined the number of deaths and DALYs, as well as age-standardized mortality rate (ASMR) and DALYs rate (ASDR) by sex, socio-demographic index (SDI), countries, and regions. Population attributable fractions (PAFs) were adopted to identify age groups vulnerable to ozone-related COPD. Estimated annual percentage changes (EAPCs) were calculated to assess the temporal trend of ozone-attributable COPD burden (e.g., ASMR and ASDR) between 1990 and 2019, using generalized linear models. Spearman rank correlation was applied to measure the relationships of estimated ASMR, ASDR, and EAPC with SDI. In 2019, COPD attributable to ambient ozone gave rise to 365.22 (95% uncertainty interval: 174.93 to 564.27) thousand deaths and 6.21 (2.99 to 9.63) million DALYs globally, representing a corresponding increase of 76.11% and 56.37% versus 1990. During 1990-2019, however, a yearly decline of 1.07% (0.81 to 1.33) was observed for ASMR and 1.30% (1.07 to 1.52) for ASDR. Considerable gender inequality continues in ozone-attributable COPD burden, with much greater impacts among men, and the gap is enlarged with the increase of age. In all age groups, the fractional contribution of ozone to COPD burden exhibited an overall increasing trend globally for both deaths (8.22% in 1990 versus 11.13% in 2019) and DALYs (6.70% in 1990 versus 8.34% in 2019). The burden of COPD caused by ambient ozone varied substantially by geographical and socioeconomic regions. In 2019, the greatest ASMR and ASDR were seen in South Asia, followed by East Asia and Central Sub-Saharan Africa. Despite the clear drop of age-standardized rates (EAPC<0) in high, high-middle, and middle SDI regions, ASMR and ASDR in low and low-middle SDI regions continuously raised between 1990 and 2019. Higher SDI was found to be associated with lower EAPCs in ASMR (rs=-0.4405, p<0.001) and ASDR (rs=-0.4510, p<0.001). Although the global ASMR and ASDR of COPD attributable to ambient ozone have decreased from 1990 to 2019, there has been an unnegligible increase in some low and low-middle SDI regions such as Southeast Asia, South Asia, and Andean Latin America. Findings may have some implications for formulating targeted plans and policies for future COPD prevention and ambient ozone management in different regions.
Collapse
Affiliation(s)
- Yaqi Wang
- Department of Epidemiology and Biostatistics, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430065, China
| | - Kai Wang
- Department of Epidemiology and Biostatistics, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430065, China
| | - Wenlin Cheng
- Department of Epidemiology and Biostatistics, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430065, China
| | - Yunquan Zhang
- Department of Epidemiology and Biostatistics, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430065, China.
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, Wuhan University of Science and Technology, Wuhan, 430065, China.
| |
Collapse
|
36
|
A Case Study on the Assessment of Chemical and Physical Pollution Levels during the Copying Process. SUSTAINABILITY 2022. [DOI: 10.3390/su14031287] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
In accordance with sustainable development goals (SDG’s), urgent action should be taken to make the societal and natural environments better for human beings. People spend most of their time indoors, therefore growing attention is devoted to address indoor air pollution. When the sources of anthropogenic indoor air pollution (copiers, laser printers) are operated indoors, then chemical and physical indoor air pollution may be higher than air pollution outdoors. Ozone, aerosol particles and volatile organic compounds are the result of pollution caused by copiers and printers. The research was carried out in a copying room by recording chemical (ozone and aerosol particles) and physical (noise) environmental pollution. To determine instantaneous ozone concentrations in the copying room, an ozone analyzer O3 41M was used, while to evaluate the effect of ozone on the ambient air of the copying room, passive samplers were used. To determine the number and concentration of aerosol particles in the ambient air of the office, a particle counter AZ-5 was used. In addition, a DrDAQ data logger was used to measure noise emitted by the copier and ambient temperature as well as relative air humidity. It was found that the distribution of ozone and aerosol particles in the copying room was mostly determined by the copying intensity. The maximum concentration of ozone and aerosol particles was determined during automatic copying (91–120 copies/min).
Collapse
|
37
|
Kang I, McCreery A, Azimi P, Gramigna A, Baca G, Abromitis K, Wang M, Zeng Y, Scheu R, Crowder T, Evens A, Stephens B. Indoor air quality impacts of residential mechanical ventilation system retrofits in existing homes in Chicago, IL. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 804:150129. [PMID: 34798726 DOI: 10.1016/j.scitotenv.2021.150129] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 08/21/2021] [Accepted: 08/31/2021] [Indexed: 06/13/2023]
Abstract
Mechanical ventilation systems are used in residences to introduce ventilation air and dilute indoor-generated pollutants. A variety of ventilation system types can be used in home retrofits, influencing indoor air quality (IAQ) in different ways. Here we describe the Breathe Easy Project, a >2-year longitudinal, pseudo-randomized, crossover study designed to assess IAQ and adult asthma outcomes before and after installing residential mechanical ventilation systems in 40 existing homes in Chicago, IL. Each home received one of three types of ventilation systems: continuous exhaust-only, intermittent powered central-fan-integrated-supply (CFIS), or continuous balanced system with an energy recovery ventilator (ERV). Homes with central heating and/or cooling systems also received MERV 10 filter replacements. Approximately weeklong field measurements were conducted at each home on a quarterly basis throughout the study to monitor environmental conditions, ventilation operation, and indoor and outdoor pollutants, including size-resolved particles (0.3-10 μm), ozone (O3), nitrogen dioxide (NO2), carbon dioxide (CO2), carbon monoxide (CO), and indoor formaldehyde (HCHO). Mean reductions in indoor/outdoor (I/O) ratios across all systems after the intervention were approximately 12% (p = 0.001), 10% (p = 0.008), 42% (p < 0.001), 39% (p = 0.002), and 33% (p = 0.007), for CO2, NO2, and estimated PM1, PM2.5, and PM10, respectively. There was a reduction in I/O ratios for all measured constituents with each type of system, on average, but with varying magnitude and levels of statistical significance. The magnitudes of mean differences in I/O pollutant concentrations ratios were generally largest for most pollutants in the homes that received continuous balanced with ERV and smallest in the homes that received intermittent CFIS systems, with apparent benefits to providing ventilation continuously rather than intermittently. All ventilation system types maintained similar indoor temperatures during pre- and post-intervention periods.
Collapse
Affiliation(s)
- Insung Kang
- Department of Civil, Architectural, and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | | | - Parham Azimi
- Department of Environmental Health, Harvard T.H. Chan School of Public Health, Boston, MA, USA
| | | | | | - Kari Abromitis
- Department of Civil, Architectural, and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Mingyu Wang
- Department of Civil, Architectural, and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Yicheng Zeng
- Department of Civil, Architectural, and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | | | | | | | - Brent Stephens
- Department of Civil, Architectural, and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA.
| |
Collapse
|
38
|
Nazaroff WW, Weschler CJ. Indoor ozone: Concentrations and influencing factors. INDOOR AIR 2022; 32:e12942. [PMID: 34609012 DOI: 10.1111/ina.12942] [Citation(s) in RCA: 42] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 09/21/2021] [Accepted: 09/24/2021] [Indexed: 05/03/2023]
Abstract
Because people spend most of their time indoors, much of their exposure to ozone occurs in buildings, which are partially protective against outdoor ozone. Measurements in approximately 2000 indoor environments (residences, schools, and offices) show a central tendency for average indoor ozone concentration of 4-6 ppb and an indoor to outdoor concentration ratio of about 25%. Considerable variability in this ratio exists among buildings, as influenced by seven building-associated factors: ozone removal in mechanical ventilation systems, ozone penetration through the building envelope, air-change rates, ozone loss rate on fixed indoor surfaces, ozone loss rate on human occupants, ozone loss by homogeneous reaction with nitrogen oxides, and ozone loss by reaction with gas-phase organics. Among these, the most important are air-change rates, ozone loss rate on fixed indoor surfaces, and, in densely occupied spaces, ozone loss rate on human occupants. Although most indoor ozone originates outdoors and enters with ventilation air, indoor emission sources can materially increase indoor ozone concentrations. Mitigation technologies to reduce indoor ozone concentrations are available or are being investigated. The most mature of these technologies, activated carbon filtration of mechanical ventilation supply air, shows a high modeled health-benefit to cost ratio when applied in densely occupied spaces.
Collapse
Affiliation(s)
- William W Nazaroff
- Department of Civil and Environmental Engineering, University of California, Berkeley, CA, USA
| | - Charles J Weschler
- Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, NJ, USA
- International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby, Denmark
| |
Collapse
|
39
|
Ji J, Yu Y, Cao S, Huang H. Enhanced activity and water tolerance promoted by Ce on MnO/ZSM-5 for ozone decomposition. CHEMOSPHERE 2021; 280:130664. [PMID: 34162073 DOI: 10.1016/j.chemosphere.2021.130664] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Revised: 03/24/2021] [Accepted: 04/22/2021] [Indexed: 06/13/2023]
Abstract
Catalytic decomposition is a promising way to eliminate ozone using manganese oxides. However, water-induced deactivation of the catalysts remains a challenge for further application. In this work, a series of Ce-promoted MnO supported on ZSM-5 (Mn-xCe/ZSM-5) were developed for ozone decomposition, which exhibited superior catalytic performance. The catalysts were characterized by multiple techniques. It is indicated that MnO was highly dispersed on ZSM-5 (Mn/ZSM-5), accounting for the high performance of ozone decomposition. Addition of Ce in Mn/ZSM-5 formed abundant redox pairs that promoted electron transfer, and thus exhibited superior ozone decomposition activity. Mn-3Ce/ZSM-5 with medium Ce loading showed the maximum activity by exposing the most active sites. Furthermore, Mn-3Ce/ZSM-5 was highly water-resistant in comparison with Mn/ZSM-5 by modulating the surface acidic property to be beneficial for the water desorption. This work provides an efficient and facile way to fabricate Ce-promoted Mn with low valence for effective and stable decomposition of ozone at room temperature.
Collapse
Affiliation(s)
- Jian Ji
- School of Environmental Science and Engineering, China.
| | - Yi Yu
- School of Environmental Science and Engineering, China
| | - Shuo Cao
- School of Environmental Science and Engineering, China
| | - Haibao Huang
- School of Environmental Science and Engineering, China; Guangdong Indoor Air Pollution Control Engineering Research Center, Sun Yat-sen University, 132 East Waihuan Road, Guangzhou, 510006, China.
| |
Collapse
|
40
|
Falcó I, Randazzo W, Sánchez G, Vilarroig J, Climent J, Chiva S, Chica A, Navarro-Laboulais J. Experimental and CFD evaluation of ozone efficacy against coronavirus and enteric virus contamination on public transport surfaces. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING 2021; 9:106217. [PMID: 34422551 PMCID: PMC8367738 DOI: 10.1016/j.jece.2021.106217] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 07/31/2021] [Accepted: 08/13/2021] [Indexed: 05/16/2023]
Abstract
The limited information about the routes of the transmission of SARS-CoV-2 within the ongoing pandemic scenario mobilized the administration, industry and academy to develop sanitation and disinfection systems for public and private spaces. Ozone has been proposed as an effective disinfection method against enveloped and non-enveloped viruses, including viruses with similar morphology to SARS-CoV-2. Due to this efficacy, numerous gaseous and aqueous phase ozone applications have emerged potentially to inhibit virus persistence in aerosols, surfaces, and water. In this work, a numerical model, a RANS CFD model for ozone dispersion inside tram and underground coach has been developed including the chemical self-decomposition and surface reactions of the ozone. The CFD model has been developed for a real tram coach of 28.6 × 2.4 × 2.2 m (L × W × H) using 1.76 million nodes and the Menter's shear stress transport turbulence model. The model predicts the O3 concentration needed to meet disinfection criteria and the fluid dynamics inside the public transport coach. The effectiveness of the system has been validated with laboratory and field tests in real full-scale coach using porcine epidemic diarrhea virus (PEDV) and murine norovirus (MNV-1) as SARS-CoV-2 and human norovirus surrogates, respectively. Lab-scale experiments on plastic surfaces demonstrated O3 disinfection (100 ppm, 95% RH, 25 min) inactivate > 99.8% MNV-1 and PEDV. Additionally, field tests in real full-scale coach demostrate the efficacy of the system as > 98.6% of infectious MNV-1 and > 96.3% PEDV were inactivated.
Collapse
Affiliation(s)
- Irene Falcó
- Department of Preservation and Food Safety Technologies, Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna, 46980 Valencia, Spain
| | - Walter Randazzo
- Department of Preservation and Food Safety Technologies, Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna, 46980 Valencia, Spain
| | - Gloria Sánchez
- Department of Preservation and Food Safety Technologies, Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna, 46980 Valencia, Spain
| | - Jose Vilarroig
- Hydrodynamic and Environmental Services, Av. del Mar, 53, 12003 Castellón, Spain
| | - Javier Climent
- Hydrodynamic and Environmental Services, Av. del Mar, 53, 12003 Castellón, Spain
| | - Sergio Chiva
- Universitat Jaume I, Department of Mechanical Engineering and Construction, Av. Vicent Sos Baynat, s/n, 12071 Castellón, Spain
| | - A Chica
- Instituto de Tecnología Química, Universitat Politècnica de València-Consejo Superior de Investigaciones Científicas, Avd. de Los Naranjos s/n, 46022 Valencia, Spain
| | - J Navarro-Laboulais
- Department of Chemical and Nuclear Engineering, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain
| |
Collapse
|
41
|
LaKind JS, Burns CJ, Pottenger LH, Naiman DQ, Goodman JE, Marchitti SA. Does ozone inhalation cause adverse metabolic effects in humans? A systematic review. Crit Rev Toxicol 2021; 51:467-508. [PMID: 34569909 DOI: 10.1080/10408444.2021.1965086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
We utilized a practical, transparent approach for systematically reviewing a chemical-specific evidence base. This approach was used for a case study of ozone inhalation exposure and adverse metabolic effects (overweight/obesity, Type 1 diabetes [T1D], Type 2 diabetes [T2D], and metabolic syndrome). We followed the basic principles of systematic review. Studies were defined as "Suitable" or "Supplemental." The evidence for Suitable studies was characterized as strong or weak. An overall causality judgment for each outcome was then determined as either causal, suggestive, insufficient, or not likely. Fifteen epidemiologic and 33 toxicologic studies were Suitable for evidence synthesis. The strength of the human evidence was weak for all outcomes. The toxicologic evidence was weak for all outcomes except two: body weight, and impaired glucose tolerance/homeostasis and fasting/baseline hyperglycemia. The combined epidemiologic and toxicologic evidence was categorized as weak for overweight/obesity, T1D, and metabolic syndrome,. The association between ozone exposure and T2D was determined to be insufficient or suggestive. The streamlined approach described in this paper is transparent and focuses on key elements. As systematic review guidelines are becoming increasingly complex, it is worth exploring the extent to which related health outcomes should be combined or kept distinct, and the merits of focusing on critical elements to select studies suitable for causal inference. We recommend that systematic review results be used to target discussions around specific research needs for advancing causal determinations.
Collapse
Affiliation(s)
- Judy S LaKind
- LaKind Associates, LLC, Catonsville, MD, USA.,Department of Epidemiology and Public Health, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Carol J Burns
- Burns Epidemiology Consulting, LLC, Sanford, MI, USA
| | | | - Daniel Q Naiman
- Department of Applied Mathematics and Statistics, Johns Hopkins University, Baltimore, MD, USA
| | | | | |
Collapse
|
42
|
Collins DB, Farmer DK. Unintended Consequences of Air Cleaning Chemistry. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:12172-12179. [PMID: 34464124 DOI: 10.1021/acs.est.1c02582] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Amplified interest in maintaining clean indoor air associated with the airborne transmission risks of SARS-CoV-2 have led to an expansion in the market for commercially available air cleaning systems. While the optimal way to mitigate indoor air pollutants or contaminants is to control (remove) the source, air cleaners are a tool for use when absolute source control is not possible. Interventions for indoor air quality management include physical removal of pollutants through ventilation or collection on filters and sorbent materials, along with chemically reactive processes that transform pollutants or seek to deactivate biological entities. This perspective intends to highlight the perhaps unintended consequences of various air cleaning approaches via indoor air chemistry. Introduction of new chemical agents or reactive processes can initiate complex chemistry that results in the release of reactive intermediates and/or byproducts into the indoor environment. Since air cleaning systems are often continuously running to maximize their effectiveness and most people spend a vast majority of their time indoors, human exposure to both primary and secondary products from air cleaners may represent significant exposure risk. This Perspective highlights the need for further study of chemically reactive air cleaning and disinfection methods before broader adoption.
Collapse
Affiliation(s)
- Douglas B Collins
- Department of Chemistry, Bucknell University, Lewisburg, Pennsylvania 17837, United States
| | - Delphine K Farmer
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| |
Collapse
|
43
|
Tang X, González NR, Russell ML, Maddalena RL, Gundel LA, Destaillats H. Chemical changes in thirdhand smoke associated with remediation using an ozone generator. ENVIRONMENTAL RESEARCH 2021; 198:110462. [PMID: 33217439 DOI: 10.1016/j.envres.2020.110462] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 10/13/2020] [Accepted: 11/09/2020] [Indexed: 06/11/2023]
Abstract
Ozonation is a common remediation approach to eliminate odors from mold, tobacco and fire damage in buildings. Little information exists to: 1) assess its effectiveness; 2) provide guidance on operation conditions; and 3) identify potential risks associated with the presence of indoor ozone and ozonation byproducts. The goal of this study is to evaluate chemical changes in thirdhand smoke (THS) aerosols induced by high levels of ozone, in comparison with THS aerosols aged under similar conditions in the absence of ozone. Samples representing different stages of smoke aging in the absence of ozone, including freshly emitted secondhand smoke (SHS) and THS, were collected inside an 18-m3 room-sized chamber over a period of 42 h after six cigarettes were consumed. The experiments involved collection and analysis of gas phase species including volatile organic compounds (VOCs), volatile carbonyls, semivolatile organic compounds (SVOCs), and particulate matter. VOC analysis was carried out by gas chromatography/mass spectrometry with a thermal desorption inlet (TD-GC/MS), and volatile carbonyls were analyzed by on-line derivatization with dinitrophenylhydrazine (DNPH), followed by liquid chromatography with UV/VIS detection. SVOCs were extracted from XAD-coated denuders and Teflon-coated fiberglass filters in the absence of ozone. In those extracts, tobacco-specific nitrosamines (TSNAs) and other SVOCs were analyzed by gas chromatography with positive chemical ionization-triple quadrupole mass spectrometric detection (GC/PCI-QQQ-MS), and polycyclic aromatic hydrocarbons (PAHs) were quantified by gas chromatography with ion trap mass spectrometric detection (GC/IT-MS) in selected ion monitoring mode. Particulate matter concentration was determined gravimetrically. In a second experiment, a 300 mg h-1 commercial ozone generator was operated during 1 h, one day after smoke was generated, to evaluate the remediation of THS by ozonation. VOCs and volatile carbonyls were analyzed before and after ozonation. Extracts from fabrics that were exposed in the chamber before and after ozonation as surrogates for indoor furnishings were analyzed by GC/IT-MS, and aerosol size distribution was studied with a scanning mobility particle sizer. Ozone concentration was measured with a photometric detector. An estimated 175 mg ozone reacted with THS after 1 h of treatment, corresponding to 58% of the total O3 released during that period. Fabric-bound nicotine was depleted after ozonation, and the surface concentration of PAHs adsorbed to fabric specimens decreased by an order of magnitude due to reaction with ozone, reaching pre-smoking levels. These results suggest that ozonation has the potential to remove harmful THS chemicals from indoor surfaces. However, gas phase concentrations of volatile carbonyls, including formaldehyde, acetaldehyde and acetone were higher immediately after ozonation. Ultrafine particles (UFP, in most cases with size <60 nm) were a major ozonation byproduct. UFP number concentrations peaked shortly after ozonation ended, and remained at higher-than background levels for several hours. Based on these results, minimum re-entry times after ozone treatment were predicted for different indoor scenarios. Clearly defining re-entry times can serve as a practical measure to prevent acute exposures to ozone and harmful ozonation byproducts after treatment. This study evaluated potential benefits and risks associated with THS remediation using ozone, providing insights into this technology.
Collapse
Affiliation(s)
- Xiaochen Tang
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, CA, USA.
| | - Noelia Ramírez González
- Institut d'Investigació Sanitària Pere Virgili, Universitat Rovira i Virgili, Department of Electronic Engineering, Tarragona, Spain; CIBER de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Instituto de Salud Carlos III, Madrid, Spain
| | - Marion L Russell
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
| | - Randy L Maddalena
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
| | - Lara A Gundel
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
| | - Hugo Destaillats
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, CA, USA.
| |
Collapse
|
44
|
Abstract
Outdoor ozone transported indoors initiates oxidative chemistry, forming volatile organic products. The influence of ozone chemistry on indoor air composition has not been directly quantified in normally occupied residences. Here, we explore indoor ozone chemistry in a house in California with two adult inhabitants. We utilize space- and time-resolved measurements of ozone and volatile organic compounds (VOCs) acquired over an 8-wk summer campaign. Despite overall low indoor ozone concentrations (mean value of 4.3 ppb) and a relatively low indoor ozone decay constant (1.3 h-1), we identified multiple VOCs exhibiting clear contributions from ozone-initiated chemistry indoors. These chemicals include 6-methyl-5-hepten-2-one (6-MHO), 4-oxopentanal (4-OPA), nonenal, and C8-C12 saturated aldehydes, which are among the commonly reported products from laboratory studies of ozone interactions with indoor surfaces and with human skin lipids. These VOCs together accounted for ≥12% molecular yield with respect to house-wide consumed ozone, with the highest net product yield for nonanal (≥3.5%), followed by 6-MHO (2.7%) and 4-OPA (2.6%). Although 6-MHO and 4-OPA are prominent ozonolysis products of skin lipids (specifically squalene), ozone reaction with the body envelopes of the two occupants in this house are insufficient to explain the observed yields. Relatedly, we observed that ozone-driven chemistry continued to produce 6-MHO and 4-OPA even after the occupants had been away from the house for 5 d. These observations provide evidence that skin lipids transferred to indoor surfaces made substantial contributions to ozone reactivity in the studied house.
Collapse
|
45
|
Fazli T, Dong X, Fu JS, Stephens B. Predicting U.S. Residential Building Energy Use and Indoor Pollutant Exposures in the Mid-21st Century. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:3219-3228. [PMID: 33591182 DOI: 10.1021/acs.est.0c06308] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The extent to which climate change and other factors will influence building energy use and population exposures to indoor pollutants is not well understood. Here, we develop and apply nationally representative residential energy and indoor pollutant model sets to estimate energy use, indoor pollutant concentrations, and associated chronic health outcomes across the U.S. residential building stock in the mid-21st century. The models incorporate expected changes in meteorological and ambient air quality conditions associated with IPCC RCP 8.5 and assumptions for changes in housing characteristics and population movements while keeping other less predictable factors constant. Site and source energy consumption for residential space-conditioning are predicted to decrease by ∼37-43 and ∼20-31%, respectively, in the 2050s compared to those in a 2010s reference scenario. Population-average indoor concentrations of pollutants of ambient origin are expected to decrease, except for O3. Holding indoor emission factors constant, indoor concentrations of pollutants with intermittent indoor sources are expected to decrease by <5% (PM2.5) to >30% (NO2); indoor concentrations of pollutants with persistent indoor sources (e.g., volatile organic compounds (VOCs)) are predicted to increase by ∼15-45%. We estimate negligible changes in disability-adjusted life-years (DALYs) lost associated with residential indoor pollutant exposures, well within uncertainty, although the attribution among pollutants is predicted to vary.
Collapse
Affiliation(s)
- Torkan Fazli
- Department of Civil, Architectural, and Environmental Engineering, Illinois Institute of Technology, Chicago, Illinois 60616, United States
| | - Xinyi Dong
- Department of Civil and Environmental Engineering, University of Tennessee, Knoxville, Knoxville, Tennessee 37996, United States
| | - Joshua S Fu
- Department of Civil and Environmental Engineering, University of Tennessee, Knoxville, Knoxville, Tennessee 37996, United States
- Computational Earth Sciences Group, Computational Sciences and Engineering Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, United States
| | - Brent Stephens
- Department of Civil, Architectural, and Environmental Engineering, Illinois Institute of Technology, Chicago, Illinois 60616, United States
| |
Collapse
|
46
|
Zhang M, Xiong J, Liu Y, Misztal PK, Goldstein AH. Physical-Chemical Coupling Model for Characterizing the Reaction of Ozone with Squalene in Realistic Indoor Environments. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:1690-1698. [PMID: 33464056 DOI: 10.1021/acs.est.0c06216] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Squalene can react with indoor ozone to generate a series of volatile and semi-volatile organic compounds, some of which may be skin or respiratory irritants, causing adverse health effects. Better understanding of the ozone/squalene reaction and product transport characteristics is thus important. In this study, we developed a physical-chemical coupling model to describe the behavior of ozone/squalene reaction products, that is, 6-methyl-5-hepten-2-one (6-MHO) and 4-oxopentanal (4-OPA) in the gas phase and skin, by considering the chemical reaction and physical transport processes (external convection, internal diffusion, and surface uptake). Experiments without intervention were performed in a single-family house in California utilizing time- and space-resolved measurements. The key parameters in the model were extracted from 5 day data and then used to predict the behaviors in some other days. Predictions from the present model can reproduce the concentration profiles of the three compounds (ozone, 6-MHO, and 4-OPA) well (R2 = 0.82-0.89), indicating high accuracy of the model. Exposure analysis shows that the total amount of 6-MHO and 4-OPA entering the blood capillaries in 4 days can reach 14.6 and 30.1 μg, respectively. The contribution of different sinks to ozone removal in the tested realistic indoor environment was also analyzed.
Collapse
Affiliation(s)
- Meixia Zhang
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Jianyin Xiong
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, China
- Department of Environmental Science, Policy and Management, University of California, Berkeley, California 94720, United States
| | - Yingjun Liu
- Department of Environmental Science, Policy and Management, University of California, Berkeley, California 94720, United States
- BIC-ESAT and SKL-ESPC, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Pawel K Misztal
- Department of Environmental Science, Policy and Management, University of California, Berkeley, California 94720, United States
- Department of Civil, Architectural and Environmental Engineering, University of Texas at Austin, Austin, Texas 78712, United States
| | - Allen H Goldstein
- Department of Environmental Science, Policy and Management, University of California, Berkeley, California 94720, United States
- Department of Civil and Environmental Engineering, University of California, Berkeley, California 94720, United States
| |
Collapse
|
47
|
Shin HH, Gogna P, Maquiling A, Parajuli RP, Haque L, Burr B. Comparison of hospitalization and mortality associated with short-term exposure to ambient ozone and PM 2.5 in Canada. CHEMOSPHERE 2021; 265:128683. [PMID: 33158503 DOI: 10.1016/j.chemosphere.2020.128683] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 10/15/2020] [Accepted: 10/19/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND Hospitalization and mortality (H-M) have been linked to air pollution separately. However, previous studies have not adequately compared whether air pollution is a stronger risk factor for hospitalization or mortality. This study aimed to investigate differences in H-M risk from short-term ozone and PM2.5 exposures, and determine whether differences are modified by season, age, and sex. METHODS Daily ozone, PM2.5, temperature, and all-cause H-M counts (ICD-10, A00-R99) were collected for 22-24 Canadian cities for up to 29 years. Generalized additive Poisson models were employed to estimate associations between each pollutant and health outcome, which were compared across season (warm, cold, or year-round), age (all ages or seniors > 65), and sex. RESULTS Overall, ozone and PM2.5 showed higher season-specific risk of mortality than hospitalization: warm-season ozone: 0.54% (95% credible interval, 0.20, 0.85) vs. 0.14% (0.02, 0.27) per 10 ppb; and year-round PM2.5: 0.90% (0.33, 1.41) vs. 0.29% (0.03, 0.56) per 10 μg/m3. While age showed little H-M difference, sex appeared to be a modifier of H-M risk. While females had higher mortality risk, males had higher hospitalization risk: for females, ozone 0.87% (0.36, 1.35) vs. -0.03% (-0.18, 0.11) and PM2.5 1.19% (0.40, 1.90) vs. 0.19% (-0.10, 0.47); and for males ozone 0.20% (-0.28, 0.65) vs. 0.35% (0.18, 0.51). CONCLUSION This study found H-M differences attributable to ozone and PM2.5, suggesting that both are stronger risk factors for mortality than hospitalization. In addition, there were clear H-M differences by sex: specifically, females showed higher mortality risk and males showed higher hospitalization risk.
Collapse
Affiliation(s)
- Hwashin Hyun Shin
- Environmental Health Science and Research Bureau, Health Canada, Ottawa, ON, Canada; Department of Mathematics and Statistics, Queen's University, Kingston, ON, Canada.
| | - Priyanka Gogna
- Department of Public Health Sciences, Queen's University, Kingston, ON, Canada.
| | - Aubrey Maquiling
- Environmental Health Science and Research Bureau, Health Canada, Ottawa, ON, Canada.
| | | | - Lani Haque
- Environmental Health Science and Research Bureau, Health Canada, Ottawa, ON, Canada.
| | - Benjamin Burr
- Department of Mathematics and Statistics, Carleton University, Ottawa, ON, Canada.
| |
Collapse
|
48
|
Goldstein AH, Nazaroff WW, Weschler CJ, Williams J. How Do Indoor Environments Affect Air Pollution Exposure? ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:100-108. [PMID: 33284612 DOI: 10.1021/acs.est.0c05727] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Affiliation(s)
- Allen H Goldstein
- Department of Environmental Science, Policy, and Management University of California, Berkeley, California 94720, United States
- Department of Civil and Environmental Engineering, University of California, Berkeley, California 94720, United States
| | - William W Nazaroff
- Department of Civil and Environmental Engineering, University of California, Berkeley, California 94720, United States
| | - Charles J Weschler
- International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Lyngby 2800, Denmark
- Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, New Jersey 08854, United States
| | | |
Collapse
|
49
|
Wang N, Zannoni N, Ernle L, Bekö G, Wargocki P, Li M, Weschler CJ, Williams J. Total OH Reactivity of Emissions from Humans: In Situ Measurement and Budget Analysis. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:149-159. [PMID: 33295177 PMCID: PMC7788569 DOI: 10.1021/acs.est.0c04206] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Humans are a potent, mobile source of various volatile organic compounds (VOCs) in indoor environments. Such direct anthropogenic emissions are gaining importance, as those from furnishings and building materials have become better regulated and energy efficient homes may reduce ventilation. While previous studies have characterized human emissions in indoor environments, the question remains whether VOCs remain unidentified by current measuring techniques. In this study conducted in a climate chamber occupied by four people, the total OH reactivity of air was quantified, together with multiple VOCs measured by proton transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS) and fast gas chromatography-mass spectrometry (fast-GC-MS). Whole-body, breath, and dermal emissions were assessed. The comparison of directly measured OH reactivity and that of the summed reactivity of individually measured species revealed no significant shortfall. Ozone exposure (37 ppb) was found to have little influence on breath OH reactivity but enhanced dermal OH reactivity significantly. Without ozone, the whole-body OH reactivity was dominated by breath emissions, mostly isoprene (76%). With ozone present, OH reactivity nearly doubled, with the increase being mainly caused by dermal emissions of mostly carbonyl compounds (57%). No significant difference in total OH reactivity was observed for different age groups (teenagers/young adults/seniors) without ozone. With ozone present, the total OH reactivity decreased slightly with increasing age.
Collapse
Affiliation(s)
- Nijing Wang
- Max
Planck Institute for Chemistry, Mainz 55128, Germany
| | - Nora Zannoni
- Max
Planck Institute for Chemistry, Mainz 55128, Germany
| | - Lisa Ernle
- Max
Planck Institute for Chemistry, Mainz 55128, Germany
| | - Gabriel Bekö
- International
Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Lyngby 2800, Denmark
| | - Pawel Wargocki
- International
Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Lyngby 2800, Denmark
| | - Mengze Li
- Max
Planck Institute for Chemistry, Mainz 55128, Germany
| | - Charles J. Weschler
- International
Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Lyngby 2800, Denmark
- Environmental
and Occupational Health Sciences Institute, Rutgers University, Piscataway, New Jersey 08854, United States
| | - Jonathan Williams
- Max
Planck Institute for Chemistry, Mainz 55128, Germany
- The
Cyprus Institute, Nicosia 2121, Cyprus
| |
Collapse
|
50
|
Kruza M, McFiggans G, Waring M, Wells J, Carslaw N. Indoor secondary organic aerosols: Towards an improved representation of their formation and composition in models. ATMOSPHERIC ENVIRONMENT: X 2020; 240:10.1016/j.atmosenv.2020.117784. [PMID: 33594348 PMCID: PMC7884095 DOI: 10.1016/j.atmosenv.2020.117784] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
The formation of secondary organic aerosol (SOA) indoors is one of the many consequences of the rich and complex chemistry that occurs therein. Given particulate matter has well documented health effects, we need to understand the mechanism for SOA formation indoors and its resulting composition. This study evaluates some uncertainties that exist in quantifying gas-to-particle partitioning of SOA-forming compounds using an indoor detailed chemical model. In particular, we investigate the impacts of using different methods to estimate compound vapour pressures as well as simulating the formation of highly oxygenated organic molecules (HOM) via auto-oxidation on SOA formation indoors. Estimation of vapour pressures for 136 α-pinene oxidation species by six investigated methods led to standard deviations of 28-216%. Inclusion of HOM formation improved model performance across three of the six assessed vapour pressure estimation methods when comparing against experimental data, particularly when the NO2 concentration was relatively high. We also explored the predicted SOA composition using two product classification methods, the first assuming the molecule is dominated by one functionality according to its name, and the second accounting for the fractional weighting of each functional group within a molecule. The SOA composition was dominated by the HOM species when the NO2-to-α-terpineol ratio was high for both product classification methods, as these conditions promoted formation of the nitrate radical and hence formation of HOM monomers. As the NO2-to-α-terpineol ratio decreased, peroxides and acids dominated the simple classification, whereas for the fractional classification, carbonyl and alcohol groups became more important.
Collapse
Affiliation(s)
- M. Kruza
- Department of Environment and Geography, University of York, Wentworth Way, York, YO10 5NG, UK
| | - G. McFiggans
- School of Earth and Environmental Sciences, University of Manchester, Manchester, UK
| | - M.S. Waring
- Department of Civil, Architectural and Environmental Engineering, Drexel University, Philadelphia, PA, USA
| | - J.R. Wells
- National Institute for Occupational Safety and Health, Morgantown, WV, USA
| | - N. Carslaw
- Department of Environment and Geography, University of York, Wentworth Way, York, YO10 5NG, UK
| |
Collapse
|