1
|
Meleppat RK, Valente D, Lee S, Jonnal RS, Doble N, Zawadzki RJ. On-axis full-field swept-source optical coherence tomography for murine retinal imaging. OPTICS LETTERS 2024; 49:4630-4633. [PMID: 39146121 DOI: 10.1364/ol.531116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Accepted: 07/19/2024] [Indexed: 08/17/2024]
Abstract
A full-field swept-source optical coherence tomography (FF-SS-OCT) for in vivo murine retinal imaging is demonstrated. The on-axis FF-SS-OCT system was built in a Mach-Zehnder interferometer configuration employing a tunable laser source with an adjustable sweep rate and sweep range in conjunction with a fast 2D-CMOS camera. A large field retinal (coherent) illumination was accomplished using an imaging interface comprised of a short-focal length imaging lens and a contact lens. The magnification between the camera and retina (spatial sampling) was appropriately chosen to record the microscopic structural features of the retina in the image. A pupil stop was employed in the detection path to reject unwanted backscattering from the mouse eye and other sources and limit aberrations distorting the retinal images. In vivo mouse retinal imaging was performed at a sweep rate of 150 Hz to acquire volumes unaffected by the system vibrations, which predominated at lower frequencies. Operating the FF-SS-OCT at this speed yielded an effective axial scan rate of 20 million A-scans/s and a field of view of 820 × 410 µm (24.12° × 12.06°). High-quality retinal B-scans and enface images of the retina were obtained with the SS-FF-OCT, revealing all major retinal layers and vascular plexuses.
Collapse
|
2
|
Rathbone E, Fu D. Quantitative Optical Imaging of Oxygen in Brain Vasculature. J Phys Chem B 2024; 128:6975-6989. [PMID: 38991095 DOI: 10.1021/acs.jpcb.4c01277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/13/2024]
Abstract
The intimate relationship between neuronal activity and cerebral oxygenation underpins fundamental brain functions like cognition, sensation, and motor control. Optical imaging offers a noninvasive approach to assess brain oxygenation and often serves as an indirect proxy for neuronal activity. However, deciphering neurovascular coupling─the intricate interplay between neuronal activity, blood flow, and oxygen delivery─necessitates independent, high spatial resolution, and high temporal resolution measurements of both microvasculature oxygenation and neuronal activation. This Perspective examines the established optical techniques employed for brain oxygen imaging, specifically functional near-infrared spectroscopy, photoacoustic imaging, optical coherence tomography, and two-photon phosphorescent lifetime microscopy, highlighting their fundamental principles, strengths, and limitations. Several other emerging optical techniques are also introduced. Finally, we discuss key technological challenges and future directions for quantitative optical oxygen imaging, paving the way for a deeper understanding of oxygen metabolism in the brain.
Collapse
Affiliation(s)
- Emily Rathbone
- Department of Chemistry, University of Washington, Seattle, Washington 98195, United States
| | - Dan Fu
- Department of Chemistry, University of Washington, Seattle, Washington 98195, United States
| |
Collapse
|
3
|
Iyer RR, Žurauskas M, Rao Y, Chaney EJ, Boppart SA. Bichromatic tetraphasic full-field optical coherence microscopy. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:S22704. [PMID: 38584966 PMCID: PMC10996847 DOI: 10.1117/1.jbo.29.s2.s22704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 02/29/2024] [Accepted: 03/05/2024] [Indexed: 04/09/2024]
Abstract
Significance Full-field optical coherence microscopy (FF-OCM) is a prevalent technique for backscattering and phase imaging with epi-detection. Traditional methods have two limitations: suboptimal utilization of functional information about the sample and complicated optical design with several moving parts for phase contrast. Aim We report an OCM setup capable of generating dynamic intensity, phase, and pseudo-spectroscopic contrast with single-shot full-field video-rate imaging called bichromatic tetraphasic (BiTe) full-field OCM with no moving parts. Approach BiTe OCM resourcefully uses the phase-shifting properties of anti-reflection (AR) coatings outside the rated bandwidths to create four unique phase shifts, which are detected with two emission filters for spectroscopic contrast. Results BiTe OCM overcomes the disadvantages of previous FF-OCM setup techniques by capturing both the intensity and phase profiles without any artifacts or speckle noise for imaging scattering samples in three-dimensional (3D). BiTe OCM also utilizes the raw data effectively to generate three complementary contrasts: intensity, phase, and color. We demonstrate BiTe OCM to observe cellular dynamics, image live, and moving micro-animals in 3D, capture the spectroscopic hemodynamics of scattering tissues along with dynamic intensity and phase profiles, and image the microstructure of fall foliage with two different colors. Conclusions BiTe OCM can maximize the information efficiency of FF-OCM while maintaining overall simplicity in design for quantitative, dynamic, and spectroscopic characterization of biological samples.
Collapse
Affiliation(s)
- Rishyashring R. Iyer
- University of Illinois Urbana-Champaign, Beckman Institute for Advanced Science and Technology, Urbana, Illinois, United States
- University of Illinois Urbana-Champaign, Department of Electrical and Computer Engineering, Urbana, Illinois, United States
| | - Mantas Žurauskas
- University of Illinois Urbana-Champaign, Beckman Institute for Advanced Science and Technology, Urbana, Illinois, United States
| | - Yug Rao
- University of Illinois Urbana-Champaign, Beckman Institute for Advanced Science and Technology, Urbana, Illinois, United States
- University of Illinois Urbana-Champaign, Department of Electrical and Computer Engineering, Urbana, Illinois, United States
| | - Eric J. Chaney
- University of Illinois Urbana-Champaign, Beckman Institute for Advanced Science and Technology, Urbana, Illinois, United States
| | - Stephen A. Boppart
- University of Illinois Urbana-Champaign, Beckman Institute for Advanced Science and Technology, Urbana, Illinois, United States
- University of Illinois Urbana-Champaign, Department of Electrical and Computer Engineering, Urbana, Illinois, United States
- University of Illinois Urbana-Champaign, Department of Bioengineering, Urbana, Illinois, United States
- University of Illinois Urbana Champaign, NIH/NIBIB P41 Center for Label-free Imaging and Multiscale Biophotonics (CLIMB), Urbana, Illinois, United States
- University of Illinois Urbana-Champaign, Cancer Center at Illinois, Urbana, Illinois, United States
- University of Illinois Urbana-Champaign, Carle Illinois College of Medicine, Urbana, Illinois, United States
| |
Collapse
|
4
|
Ye T, Wang J, Yi J. Deep learning network for parallel self-denoising and segmentation in visible light optical coherence tomography of the human retina. BIOMEDICAL OPTICS EXPRESS 2023; 14:6088-6099. [PMID: 38021135 PMCID: PMC10659798 DOI: 10.1364/boe.501848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 09/25/2023] [Accepted: 10/16/2023] [Indexed: 12/01/2023]
Abstract
Visible light optical coherence tomography (VIS-OCT) of the human retina is an emerging imaging modality that uses shorter wavelengths in visible light range than conventional near-infrared (NIR) light. It provides one-micron level axial resolution to better separate stratified retinal layers, as well as microvascular oximetry. However, due to the practical limitation of laser safety and comfort, the permissible illumination power is much lower than NIR OCT, which can be challenging to obtain high-quality VIS-OCT images and subsequent image analysis. Therefore, improving VIS-OCT image quality by denoising is an essential step in the overall workflow in VIS-OCT clinical applications. In this paper, we provide the first VIS-OCT retinal image dataset from normal eyes, including retinal layer annotation and "noisy-clean" image pairs. We propose an efficient co-learning deep learning framework for parallel self-denoising and segmentation simultaneously. Both tasks synergize within the same network and improve each other's performance. The significant improvement of segmentation (2% higher Dice coefficient compared to segmentation-only process) for ganglion cell layer (GCL), inner plexiform layer (IPL) and inner nuclear layer (INL) is observed when available annotation drops to 25%, suggesting an annotation-efficient training. We also showed that the denoising model trained on our dataset generalizes well for a different scanning protocol.
Collapse
Affiliation(s)
- Tianyi Ye
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21231, USA
| | - Jingyu Wang
- Department of Ophthalmology, Johns Hopkins University, Baltimore, MD, 21231, USA
| | - Ji Yi
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21231, USA
- Department of Ophthalmology, Johns Hopkins University, Baltimore, MD, 21231, USA
| |
Collapse
|
5
|
Cuartas-Vélez C, Middelkamp HHT, van der Meer AD, van den Berg A, Bosschaart N. Tracking the dynamics of thrombus formation in a blood vessel-on-chip with visible-light optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2023; 14:5642-5655. [PMID: 38021142 PMCID: PMC10659801 DOI: 10.1364/boe.500434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 08/31/2023] [Accepted: 09/03/2023] [Indexed: 12/01/2023]
Abstract
Thrombus formation is a physiological response to damage in a blood vessel that relies on a complex interplay of platelets, coagulation factors, immune cells, and the vessel wall. The dynamics of thrombus formation are essential for a deeper understanding of many disease processes, like bleeding, wound healing, and thrombosis. However, monitoring thrombus formation is challenging due to the limited imaging options available to analyze flowing blood. In this work, we use a visible-light optical coherence tomography (vis-OCT) system to monitor the dynamic process of the formation of thrombi in a microfluidic blood vessel-on-chip (VoC) device. Inside the VoC, thrombi form in a channel lined with a monolayer of endothelial cells and perfused by human whole blood. We show that the correlation of the vis-OCT signal can be utilized as a marker for thrombus formation. By thresholding the correlation during thrombus formation, we track and quantify the growth of the thrombi over time. We validate our results with fluorescence microscopic imaging of fibrin and platelet markers at the end of the blood perfusion assay. In conclusion, we demonstrate that the correlation of the vis-OCT signal can be used to visualize both the spatial and temporal behavior of the thrombus formation in flowing human whole blood.
Collapse
Affiliation(s)
- Carlos Cuartas-Vélez
- Biomedical Photonic Imaging Group, Faculty of Science and Technology, University of Twente, Enschede, The Netherlands
| | - Heleen H. T. Middelkamp
- BIOS/Lab on a Chip, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Enschede, The Netherlands
| | - Andries D. van der Meer
- Applied Stem Cell Technologies, Faculty of Science and Technology, University of Twente, Enschede, The Netherlands
| | - Albert van den Berg
- BIOS/Lab on a Chip, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Enschede, The Netherlands
| | - Nienke Bosschaart
- Biomedical Photonic Imaging Group, Faculty of Science and Technology, University of Twente, Enschede, The Netherlands
| |
Collapse
|
6
|
Gupta AK, Meng R, Modi YS, Srinivasan VJ. Imaging human macular pigments with visible light optical coherence tomography and superluminescent diodes. OPTICS LETTERS 2023; 48:4737-4740. [PMID: 37707890 PMCID: PMC10935566 DOI: 10.1364/ol.495247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 08/04/2023] [Indexed: 09/15/2023]
Abstract
We demonstrate superluminescent diodes (SLDs) for visible light optical coherence tomography (OCT) of the human retina. SLDs are less costly than supercontinuum sources and have lower intrinsic excess noise, enabling imaging closer to the shot noise limit. While single SLDs are not broadband, they provide power concentrated at specific wavelengths relevant to retinal function. As a new, to the best of our knowledge, application, we image human macular pigments (MPs), which are thought to both aid vision and protect against advanced age-related macular degeneration. Using the unique depth-resolved capabilities of OCT, we localize MPs in depth to Henle's fibers beneath the foveal pit in the living human retina. Our approach reduces the cost of visible light OCT to nearly that of near-infrared (NIR) OCT while also providing information about clinically relevant MPs which cannot be measured in the NIR.
Collapse
Affiliation(s)
- Alok K. Gupta
- Tech4Health Institute, NYU Langone Health, New York, New York, 10010, USA
- Department of Ophthalmology, NYU Langone Health, New York, New York, 10016, USA
- NYU Tandon School of Engineering, Brooklyn, New York, New York 11201, USA
| | - Ruoyu Meng
- Tech4Health Institute, NYU Langone Health, New York, New York, 10010, USA
- NYU Tandon School of Engineering, Brooklyn, New York, New York 11201, USA
| | - Yasha S. Modi
- Department of Ophthalmology, NYU Langone Health, New York, New York, 10016, USA
| | - Vivek J. Srinivasan
- Tech4Health Institute, NYU Langone Health, New York, New York, 10010, USA
- Department of Ophthalmology, NYU Langone Health, New York, New York, 10016, USA
- NYU Tandon School of Engineering, Brooklyn, New York, New York 11201, USA
| |
Collapse
|
7
|
Asghari H. Visible wavelength time-stretch optical coherence tomography. OPTICS EXPRESS 2023; 31:24085-24096. [PMID: 37475244 DOI: 10.1364/oe.492753] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 06/21/2023] [Indexed: 07/22/2023]
Abstract
Visible light optical coherence tomography (OCT) is an emerging non-invasive imaging modality that offers new opportunities for anatomical and functional imaging of biological tissues. Time-stretch dispersive Fourier transform, also known as photonic time-stretch, is an all-optical processing method that enables real-time Fourier transformation of ultrafast optical signals and allows for OCT at high A-scan rates. In this work, a working prototype of a photonic time-stretch OCT (TS-OCT) method in the visible wavelength region is proposed and experimentally demonstrated. The proposed visible-light TS-OCT system achieves unprecedented throughput of 100 giga voxels/second and OCT volume rate of 4,000 volumes/second and can be used to expand the range of applications of TS-OCT systems.
Collapse
|
8
|
Rubinoff I, Kuranov RV, Fang R, Ghassabi Z, Wang Y, Beckmann L, Miller DA, Wollstein G, Ishikawa H, Schuman JS, Zhang HF. Adaptive spectroscopic visible-light optical coherence tomography for clinical retinal oximetry. COMMUNICATIONS MEDICINE 2023; 3:57. [PMID: 37095177 PMCID: PMC10126115 DOI: 10.1038/s43856-023-00288-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Accepted: 04/13/2023] [Indexed: 04/26/2023] Open
Abstract
BACKGROUND Retinal oxygen saturation (sO2) provides essential information about the eye's response to pathological changes that can result in vision loss. Visible-light optical coherence tomography (vis-OCT) is a noninvasive tool that has the potential to measure retinal sO2 in a clinical setting. However, its reliability is currently limited by unwanted signals referred to as spectral contaminants (SCs), and a comprehensive strategy to isolate true oxygen-dependent signals from SCs in vis-OCT is lacking. METHODS We develop an adaptive spectroscopic vis-OCT (ADS-vis-OCT) technique that can adaptively remove SCs and accurately measure sO2 under the unique conditions of each vessel. We also validate the accuracy of ADS-vis-OCT using ex vivo blood phantoms and assess its repeatability in the retina of healthy volunteers. RESULTS In ex vivo blood phantoms, ADS-vis-OCT agrees with a blood gas machine with only a 1% bias in samples with sO2 ranging from 0% to 100%. In the human retina, the root mean squared error between sO2 values in major arteries measured by ADS-vis-OCT and a pulse oximeter is 2.1% across 18 research participants. Additionally, the standard deviations of repeated ADS-vis-OCT measurements of sO2 values in smaller arteries and veins are 2.5% and 2.3%, respectively. Non-adaptive methods do not achieve comparable repeatabilities from healthy volunteers. CONCLUSIONS ADS-vis-OCT effectively removes SCs from human images, yielding accurate and repeatable sO2 measurements in retinal arteries and veins with varying diameters. This work could have important implications for the clinical use of vis-OCT to manage eye diseases.
Collapse
Affiliation(s)
- Ian Rubinoff
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Roman V Kuranov
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
- Opticent Inc., Evanston, IL, 60201, USA
| | - Raymond Fang
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Zeinab Ghassabi
- Department of Ophthalmology, New York University, New York, NY, 10017, USA
| | - Yuanbo Wang
- Currently with Department of Ophthalmology, Oregon Health & Science University, Portland, OR, 97239, USA
| | - Lisa Beckmann
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - David A Miller
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Gadi Wollstein
- Department of Ophthalmology, New York University, New York, NY, 10017, USA
| | - Hiroshi Ishikawa
- Department of Ophthalmology, New York University, New York, NY, 10017, USA
- Currently with Department of Ophthalmology, Oregon Health & Science University, Portland, OR, 97239, USA
| | - Joel S Schuman
- Department of Ophthalmology, New York University, New York, NY, 10017, USA
| | - Hao F Zhang
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA.
| |
Collapse
|
9
|
Merkle CW, Augustin M, Harper DJ, Glösmann M, Baumann B. Degeneration of Melanin-Containing Structures Observed Longitudinally in the Eyes of SOD1-/- Mice Using Intensity, Polarization, and Spectroscopic OCT. Transl Vis Sci Technol 2022; 11:28. [PMID: 36259678 PMCID: PMC9587514 DOI: 10.1167/tvst.11.10.28] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Purpose Melanin plays an important function in maintaining eye health, however there are few metrics that can be used to study retinal melanin content in vivo. Methods The slope of the spectral coefficient of variation (SSCoV) is a novel biomarker that measures chromophore concentration by analyzing the local divergence of spectral intensities using optical coherence tomography (OCT). This metric was validated in a phantom and applied in a longitudinal study of superoxide dismutase 1 knockout (SOD1−/−) mice, a model for wet and dry age-related macular degeneration. We also examined a new feature of interest in standard OCT image data, the ratio of maximum intensity in the retinal pigment epithelium to that of the choroid (RC ratio). These new biomarkers were supported by polarization-sensitive OCT and histological analysis. Results SSCoV correlated well with depolarization metrics both in phantom and in vivo with both metrics decreasing more rapidly in SOD1−/− mice with age (P < 0.05). This finding is correlated with reduced melanin pigmentation in the choroid over time. The RC ratio clearly differentiated the SOD1−/− and control groups (P < 0.0005) irrespective of time and may indicate lower retinal pigment epithelium melanin in the SOD1−/− mice. Histological analysis showed decreased melanin content and potential differences in melanin granule shape in SOD1−/− mice. Conclusions SSCoV and RC ratio biomarkers provided insights into the changes of retinal melanin in the SOD1−/− model longitudinally and noninvasively. Translational Relevance These biomarkers were designed with the potential for rapid adoption by existing clinical OCT systems without requiring new hardware.
Collapse
Affiliation(s)
- Conrad W Merkle
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Marco Augustin
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Danielle J Harper
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Martin Glösmann
- Core Facility for Research and Technology, University of Veterinary Medicine Vienna, Austria
| | - Bernhard Baumann
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| |
Collapse
|
10
|
Fang R, Rubinoff I, Zhang HF. Multiple forward scattering reduces the measured scattering coefficient of whole blood in visible-light optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2022; 13:4510-4527. [PMID: 36187273 PMCID: PMC9484418 DOI: 10.1364/boe.459607] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 07/18/2022] [Accepted: 07/19/2022] [Indexed: 05/10/2023]
Abstract
The optical properties of blood encode oxygen-dependent information. Noninvasive optical detection of these properties is increasingly desirable to extract biomarkers for tissue health. Recently, visible-light optical coherence tomography (vis-OCT) demonstrated retinal oxygen saturation (sO2) measurements by inversely measuring the oxygen-dependent absorption and scattering coefficients of whole blood. However, vis-OCT may be sensitive to optical scattering properties of whole blood, different from those reported in the literature. Incorrect assumptions of such properties can add additional uncertainties or biases to vis-OCT's sO2 model. This work investigates whole blood's scattering coefficient measured by vis-OCT. Using Monte Carlo simulation of a retinal vessel, we determined that vis-OCT almost exclusively detects multiple-scattered photons in whole blood. Meanwhile, photons mostly forward scatter in whole blood within the visible spectral range, allowing photons to maintain ballistic paths and penetrate deeply, leading to a reduction in the measured scattering coefficient. We defined a scattering scaling factor (SSF) to account for such a reduction and found that SSF varied with measurement conditions, such as numerical aperture, depth resolution, and depth selection. We further experimentally validated SSF in ex vivo blood phantoms with pre-set sO2 levels and in the human retina, both of which agreed well with our simulation.
Collapse
Affiliation(s)
- Raymond Fang
- Department of Biomedical Engineering, Northwestern University, Evanston IL 60208, USA
- These authors contributed equally to this work
| | - Ian Rubinoff
- Department of Biomedical Engineering, Northwestern University, Evanston IL 60208, USA
- These authors contributed equally to this work
| | - Hao F. Zhang
- Department of Biomedical Engineering, Northwestern University, Evanston IL 60208, USA
| |
Collapse
|
11
|
Taylor-Williams M, Spicer G, Bale G, Bohndiek SE. Noninvasive hemoglobin sensing and imaging: optical tools for disease diagnosis. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:JBO-220074VR. [PMID: 35922891 PMCID: PMC9346606 DOI: 10.1117/1.jbo.27.8.080901] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 06/27/2022] [Indexed: 05/08/2023]
Abstract
SIGNIFICANCE Measurement and imaging of hemoglobin oxygenation are used extensively in the detection and diagnosis of disease; however, the applied instruments vary widely in their depth of imaging, spatiotemporal resolution, sensitivity, accuracy, complexity, physical size, and cost. The wide variation in available instrumentation can make it challenging for end users to select the appropriate tools for their application and to understand the relative limitations of different methods. AIM We aim to provide a systematic overview of the field of hemoglobin imaging and sensing. APPROACH We reviewed the sensing and imaging methods used to analyze hemoglobin oxygenation, including pulse oximetry, spectral reflectance imaging, diffuse optical imaging, spectroscopic optical coherence tomography, photoacoustic imaging, and diffuse correlation spectroscopy. RESULTS We compared and contrasted the ability of different methods to determine hemoglobin biomarkers such as oxygenation while considering factors that influence their practical application. CONCLUSIONS We highlight key limitations in the current state-of-the-art and make suggestions for routes to advance the clinical use and interpretation of hemoglobin oxygenation information.
Collapse
Affiliation(s)
- Michaela Taylor-Williams
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom, United Kingdom
| | - Graham Spicer
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom, United Kingdom
| | - Gemma Bale
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Electrical Division, Department of Engineering, Cambridge, United Kingdom, United Kingdom
| | - Sarah E Bohndiek
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom, United Kingdom
| |
Collapse
|
12
|
Zhu L, Makita S, Oida D, Miyazawa A, Oikawa K, Mukherjee P, Lichtenegger A, Distel M, Yasuno Y. Computational refocusing of Jones matrix polarization-sensitive optical coherence tomography and investigation of defocus-induced polarization artifacts. BIOMEDICAL OPTICS EXPRESS 2022; 13:2975-2994. [PMID: 35774308 PMCID: PMC9203103 DOI: 10.1364/boe.454975] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 04/13/2022] [Accepted: 04/13/2022] [Indexed: 06/15/2023]
Abstract
Here we demonstrate a long-depth-of-focus imaging method using polarization sensitive optical coherence tomography (PS-OCT). This method involves a combination of Fresnel-diffraction-model-based phase sensitive computational refocusing and Jones-matrix based PS-OCT (JM-OCT). JM-OCT measures four complex OCT images corresponding to four polarization channels. These OCT images are computationally refocused as preserving the mutual phase consistency. This method is validated using a static phantom, postmortem zebrafish, and ex vivo porcine muscle samples. All the samples demonstrated successful computationally-refocused birefringence and degree-of-polarization-uniformity (DOPU) images. We found that defocusing induces polarization artifacts, i.e., incorrectly high birefringence values and low DOPU values, which are substantially mitigated by computational refocusing.
Collapse
Affiliation(s)
- Lida Zhu
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
| | - Shuichi Makita
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
| | - Daisuke Oida
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
| | - Arata Miyazawa
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
- Sky technology Inc., Tsukuba, Ibaraki, Japan
| | - Kensuke Oikawa
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
| | - Pradipta Mukherjee
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
| | - Antonia Lichtenegger
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Martin Distel
- Innovative Cancer Models, St. Anna Children’s Cancer Research Institute, Vienna, Austria
| | - Yoshiaki Yasuno
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
| |
Collapse
|
13
|
Wang J, Baker A, Subramanian ML, Siegel NH, Chen X, Ness S, Yi J. Simultaneous visible light optical coherence tomography and near infrared OCT angiography in retinal pathologies: A case study. Exp Biol Med (Maywood) 2022; 247:377-384. [PMID: 34904454 PMCID: PMC8919322 DOI: 10.1177/15353702211063839] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
A dual-channel optical coherence tomography system with wavelengths in the visible and near-infrared light ranges can provide both structural and functional information for retinal microvasculature simultaneously. We applied this integrated system in an ongoing clinical study of patients with various retinal pathologies. Here, we present case study results of patients with diabetic retinopathy, central retinal vein occlusion, and sickle cell retinopathy compared to a healthy subject. For the first time, this comparison validates the system's ability to detect structural anomalies in both en face and B-scan images with simultaneous retinal optical coherence tomography angiography and measurement of sO2 in parafoveal vessels that are around 20-30 µm in diameter. This integrated system represents a powerful instrument with potentially far-reaching clinical implications for the early detection and diagnosis of retinal vascular diseases.
Collapse
Affiliation(s)
- Jingyu Wang
- Department of Ophthalmology, Johns Hopkins University, Baltimore, MD 21231, USA
| | - Andrew Baker
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21231, USA
| | - Manju L Subramanian
- Department of Ophthalmology, Boston University School of Medicine, Boston Medical Center, Boston, MA 02118, USA
| | - Nicole H Siegel
- Department of Ophthalmology, Boston University School of Medicine, Boston Medical Center, Boston, MA 02118, USA
| | - Xuejing Chen
- Department of Ophthalmology, Boston University School of Medicine, Boston Medical Center, Boston, MA 02118, USA
| | - Steven Ness
- Department of Ophthalmology, Boston University School of Medicine, Boston Medical Center, Boston, MA 02118, USA
| | - Ji Yi
- Department of Ophthalmology, Johns Hopkins University, Baltimore, MD 21231, USA,Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21231, USA,Ji Yi.
| |
Collapse
|
14
|
Bernier LP, Brunner C, Cottarelli A, Balbi M. Location Matters: Navigating Regional Heterogeneity of the Neurovascular Unit. Front Cell Neurosci 2021; 15:696540. [PMID: 34276312 PMCID: PMC8277940 DOI: 10.3389/fncel.2021.696540] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Accepted: 05/31/2021] [Indexed: 12/27/2022] Open
Abstract
The neurovascular unit (NVU) of the brain is composed of multiple cell types that act synergistically to modify blood flow to locally match the energy demand of neural activity, as well as to maintain the integrity of the blood-brain barrier (BBB). It is becoming increasingly recognized that the functional specialization, as well as the cellular composition of the NVU varies spatially. This heterogeneity is encountered as variations in vascular and perivascular cells along the arteriole-capillary-venule axis, as well as through differences in NVU composition throughout anatomical regions of the brain. Given the wide variations in metabolic demands between brain regions, especially those of gray vs. white matter, the spatial heterogeneity of the NVU is critical to brain function. Here we review recent evidence demonstrating regional specialization of the NVU between brain regions, by focusing on the heterogeneity of its individual cellular components and briefly discussing novel approaches to investigate NVU diversity.
Collapse
Affiliation(s)
- Louis-Philippe Bernier
- Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, BC, Canada
| | - Clément Brunner
- Neuro-Electronics Research Flanders, Leuven, Belgium.,Vlaams Instituut voor Biotechnologie, Leuven, Belgium.,Interuniversity Microeletronics Centre, Leuven, Belgium.,Department of Neurosciences, KU Leuven, Leuven, Belgium
| | | | - Matilde Balbi
- Queensland Brain Institute, University of Queensland, Brisbane, QLD, Australia
| |
Collapse
|
15
|
Optical density based quantification of total haemoglobin concentrations with spectroscopic optical coherence tomography. Sci Rep 2021; 11:8680. [PMID: 33883617 PMCID: PMC8060256 DOI: 10.1038/s41598-021-88063-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Accepted: 04/05/2021] [Indexed: 11/21/2022] Open
Abstract
Spectroscopic optical coherence tomography (sOCT) has emerged as a new possibility for non-invasive quantification of total haemoglobin concentrations [tHb]. Recently, we demonstrated that [tHb] measured in ex-vivo human whole-blood with a conventional sOCT system achieves a precision of 9.10 g/dL with a bias of 1.50 g/dL. This precision improved by acquiring data with a combination of focus tracking and zero-delay acquisition (FZA) that compensated for experimental limitations, increasing to 3.80 g/dL with a bias of 1.50 g/dL. Nevertheless, sOCT precision should improve at least to \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\sim 2$$\end{document}∼2 g/dL to be clinically relevant. Therefore, sOCT-based [tHb] determinations require the development of new analysis methods that reduce the variability of [tHb] estimations. In this work, we aim to increase sOCT precision by retrieving the [tHb] content from a numerical optimisation of the optical density (OD), while considering the blood absorption flattening effect. The OD-based approach simplifies previous two-step Lambert–Beer fitting approaches to a single step, thereby reducing errors during the fitting procedure. We validated our model with ex-vivo [tHb] measurements on flowing whole-blood samples in the clinical range (7–23 g/dL). Our results show that, with the new model, conventional sOCT can determine [tHb] with a precision of 3.09 g/dL and a bias of 0.86 g/dL compared to a commercial blood analyser. We present further precision improvement by combining the OD methodology with FZA, leading to a precision of 2.08 g/dL with a bias of 0.46 g/dL.
Collapse
|
16
|
Ringel MJ, Tang EM, Tao YK. Advances in multimodal imaging in ophthalmology. Ther Adv Ophthalmol 2021; 13:25158414211002400. [PMID: 35187398 PMCID: PMC8855415 DOI: 10.1177/25158414211002400] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Accepted: 02/23/2021] [Indexed: 12/12/2022] Open
Abstract
Multimodality ophthalmic imaging systems aim to enhance the contrast, resolution, and functionality of existing technologies to improve disease diagnostics and therapeutic guidance. These systems include advanced acquisition and post-processing methods using optical coherence tomography (OCT), combined scanning laser ophthalmoscopy and OCT systems, adaptive optics, surgical guidance, and photoacoustic technologies. Here, we provide an overview of these ophthalmic imaging systems and their clinical and basic science applications.
Collapse
Affiliation(s)
- Morgan J. Ringel
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Eric M. Tang
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Yuankai K. Tao
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA
| |
Collapse
|
17
|
Xing F, Lee JH, Polucha C, Lee J. Design and optimization of line-field optical coherence tomography at visible wavebands. BIOMEDICAL OPTICS EXPRESS 2021; 12:1351-1365. [PMID: 33796358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 01/25/2021] [Accepted: 01/29/2021] [Indexed: 06/12/2023]
Abstract
Parallel line-field Fourier-domain optical coherence tomography (LF-FDOCT) has emerged to enable relatively higher speeds than the conventional FDOCT system. In the LF-FDOCT, one B-scan is captured at a time instead of scanning the beam to acquire hundreds of A-scans. On the other hand, spectroscopic OCT using the visible waveband provides absorption information over multiple wavelengths at each voxel. This information of spectral absorption enables quantitative measurement of blood oxygenation, voxel by voxel. Here, we presented the design and optimization of a LF-FDOCT system at the visible waveband (520-620 nm), especially using a generic Camera Link area sensor (2048 × 1088 pixels). To optimize the axial resolution and depth of imaging volume, we simulated various parameters and found that two Nyquist optima can exist, the origin and implication of which has been discussed. As a result, our system acquired 1088 A-scans in parallel at the camera's frame rate of 281 frame per second, achieving an equivalent rate of over 300,000 A-scan/s, while minimizing sacrifice in the point spread function (2.8 × 3.1 × 3.2 µm3, x × y × z) and the field of view (750 × 750 × 750 µm3). As an example of application, we presented high-speed imaging of blood oxygenation in the rodent brain cortex.
Collapse
Affiliation(s)
- Fangjian Xing
- School of Computer and Electronic information, Nanjing Normal University, Nanjing, 210023, China
- Center for Biomedical Engineering, School of Engineering, Brown University, Providence, Rhode Island 02912, USA
| | - Jang-Hoon Lee
- Center for Biomedical Engineering, School of Engineering, Brown University, Providence, Rhode Island 02912, USA
| | - Collin Polucha
- Center for Biomedical Engineering, School of Engineering, Brown University, Providence, Rhode Island 02912, USA
| | - Jonghwan Lee
- Center for Biomedical Engineering, School of Engineering, Brown University, Providence, Rhode Island 02912, USA
- Carney Institute for Brain Science, Brown University, Providence, Rhode Island 02912, USA
| |
Collapse
|
18
|
Xing F, Lee JH, Polucha C, Lee J. Design and optimization of line-field optical coherence tomography at visible wavebands. BIOMEDICAL OPTICS EXPRESS 2021; 12:1351-1365. [PMID: 33796358 PMCID: PMC7984778 DOI: 10.1364/boe.413424] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 01/25/2021] [Accepted: 01/29/2021] [Indexed: 06/17/2023]
Abstract
Parallel line-field Fourier-domain optical coherence tomography (LF-FDOCT) has emerged to enable relatively higher speeds than the conventional FDOCT system. In the LF-FDOCT, one B-scan is captured at a time instead of scanning the beam to acquire hundreds of A-scans. On the other hand, spectroscopic OCT using the visible waveband provides absorption information over multiple wavelengths at each voxel. This information of spectral absorption enables quantitative measurement of blood oxygenation, voxel by voxel. Here, we presented the design and optimization of a LF-FDOCT system at the visible waveband (520-620 nm), especially using a generic Camera Link area sensor (2048 × 1088 pixels). To optimize the axial resolution and depth of imaging volume, we simulated various parameters and found that two Nyquist optima can exist, the origin and implication of which has been discussed. As a result, our system acquired 1088 A-scans in parallel at the camera's frame rate of 281 frame per second, achieving an equivalent rate of over 300,000 A-scan/s, while minimizing sacrifice in the point spread function (2.8 × 3.1 × 3.2 µm3, x × y × z) and the field of view (750 × 750 × 750 µm3). As an example of application, we presented high-speed imaging of blood oxygenation in the rodent brain cortex.
Collapse
Affiliation(s)
- Fangjian Xing
- School of Computer and Electronic information, Nanjing Normal University, Nanjing, 210023, China
- Center for Biomedical Engineering, School of Engineering, Brown University, Providence, Rhode Island 02912, USA
| | - Jang-Hoon Lee
- Center for Biomedical Engineering, School of Engineering, Brown University, Providence, Rhode Island 02912, USA
| | - Collin Polucha
- Center for Biomedical Engineering, School of Engineering, Brown University, Providence, Rhode Island 02912, USA
| | - Jonghwan Lee
- Center for Biomedical Engineering, School of Engineering, Brown University, Providence, Rhode Island 02912, USA
- Carney Institute for Brain Science, Brown University, Providence, Rhode Island 02912, USA
| |
Collapse
|
19
|
Rubinoff I, Kuranov RV, Zhang HF. Intrinsic spectrally-dependent background in spectroscopic visible-light optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2021; 12:110-124. [PMID: 33520380 PMCID: PMC7818955 DOI: 10.1364/boe.410011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 11/15/2020] [Accepted: 11/16/2020] [Indexed: 05/10/2023]
Abstract
Visible-light optical coherence tomography (vis-OCT) has enabled new spectroscopic applications, such as retinal oximetry, as a result of increased optical absorption and scattering contacts in biological tissue and improved axial resolution. Besides extracting tissue properties from back-scattered light, spectroscopic analyses must consider spectral alterations induced by image reconstruction itself. We investigated an intrinsic spectral bias in the background noise floor, which is hereby referred to as the spectrally-dependent background (SDBG). We developed an analytical model to predict the SDBG-induced bias and validated this model using numerically simulated and experimentally acquired data. We found that SDBG systemically altered the measured spectra of blood in human retinal vessels in vis-OCT, as compared to literature data. We provided solutions to quantify and compensate for SDBG in retinal oximetry. This work is particularly significant for clinical applications of vis-OCT.
Collapse
Affiliation(s)
- Ian Rubinoff
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Roman V. Kuranov
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
- Opticent Health, Evanston, IL 60201, USA
| | - Hao F. Zhang
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
| |
Collapse
|
20
|
Kho AM, Zhang T, Zhu J, Merkle CW, Srinivasan VJ. Incoherent excess noise spectrally encodes broadband light sources. LIGHT, SCIENCE & APPLICATIONS 2020; 9:172. [PMID: 33082941 PMCID: PMC7538909 DOI: 10.1038/s41377-020-00404-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Revised: 08/26/2020] [Accepted: 09/09/2020] [Indexed: 05/09/2023]
Abstract
Across optics and photonics, excess intensity noise is often considered a liability. Here, we show that excess noise in broadband supercontinuum and superluminescent diode light sources encodes each spectral channel with unique intensity fluctuations, which actually serve a useful purpose. Specifically, we report that excess noise correlations can both characterize the spectral resolution of spectrometers and enable cross-calibration of their wavelengths across a broad bandwidth. Relative to previous methods that use broadband interferometry and narrow linewidth lasers to characterize and calibrate spectrometers, our approach is simple, comprehensive, and rapid enough to be deployed during spectrometer alignment. First, we employ this approach to aid alignment and reduce the depth-dependent degradation of the sensitivity and axial resolution in a spectrometer-based optical coherence tomography (OCT) system, revealing a new outer retinal band. Second, we achieve a pixel-to-pixel correspondence between two otherwise disparate spectrometers, enabling a robust comparison of their respective measurements. Thus, excess intensity noise has useful applications in optics and photonics.
Collapse
Affiliation(s)
- Aaron M. Kho
- Department of Biomedical Engineering, University of California Davis, Davis, CA 95616 USA
| | - Tingwei Zhang
- Department of Biomedical Engineering, University of California Davis, Davis, CA 95616 USA
| | - Jun Zhu
- Department of Biomedical Engineering, University of California Davis, Davis, CA 95616 USA
| | - Conrad W. Merkle
- Department of Biomedical Engineering, University of California Davis, Davis, CA 95616 USA
| | - Vivek J. Srinivasan
- Department of Biomedical Engineering, University of California Davis, Davis, CA 95616 USA
- Department of Ophthalmology and Vision Science, University of California Davis School of Medicine, Sacramento, CA 95817 USA
| |
Collapse
|
21
|
Zhang T, Kho AM, Srinivasan VJ. Water wavenumber calibration for visible light optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:JBO-200166LR. [PMID: 32935500 PMCID: PMC7490762 DOI: 10.1117/1.jbo.25.9.090501] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Accepted: 08/28/2020] [Indexed: 06/11/2023]
Abstract
SIGNIFICANCE Visible light optical coherence tomography (OCT) is emerging for spectroscopic and ultrahigh resolution imaging, but challenges remain. Depth-dependent dispersion limits retinal image quality and current correction approaches are cumbersome. Inconsistent group refractive indices during image reconstruction also limit reproducibility. AIM To introduce and evaluate water wavenumber calibration (WWC), which corrects depth-dependent dispersion and provides an accurate depth axis in water. APPROACH Enabled by a visible light OCT spectrometer configuration with a 3- to 4-dB sensitivity roll-off over 1 mm in air across a 90-nm bandwidth, we determine the spectral phase of a 1-mm water cell, an affine function of water wavenumber. Via WWC, we reconstruct visible light OCT human retinal images with 1.3-μm depth resolution in water. RESULTS Images clearly reveal Bruch's membrane, inner plexiform layer lamination, and a thin nerve fiber layer in the temporal parafovea. WWC halves the processing time, while achieving the same image definition as an assumption-free gold standard approach, suggesting that water wavenumber is a suitable proxy for tissue wavenumber. WWC also provides a depth axis in water without explicitly assuming a group refractive index. CONCLUSIONS WWC is a simple method that helps to realize the full potential of visible light OCT.
Collapse
Affiliation(s)
- Tingwei Zhang
- University of California Davis, Department of Biomedical Engineering, Davis, California, United States
| | - Aaron M. Kho
- University of California Davis, Department of Biomedical Engineering, Davis, California, United States
| | - Vivek J. Srinivasan
- University of California Davis, Department of Biomedical Engineering, Davis, California, United States
- University of California Davis, School of Medicine, Department of Ophthalmology and Vision Science, Sacramento, California, United States
| |
Collapse
|
22
|
Scharf J, Freund KB, Sadda S, Sarraf D. Paracentral acute middle maculopathy and the organization of the retinal capillary plexuses. Prog Retin Eye Res 2020; 81:100884. [PMID: 32783959 DOI: 10.1016/j.preteyeres.2020.100884] [Citation(s) in RCA: 84] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 07/09/2020] [Accepted: 07/10/2020] [Indexed: 02/07/2023]
Abstract
The retinal capillary vasculature serves the formidable role of supplying the metabolically active inner and middle retina. In the parafoveal region, the retinal capillary plexuses (RCP) are organized in a system of three capillary layers of varying retinal depths: the superficial capillary plexus (SCP), intermediate capillary plexus (ICP) and deep capillary plexus (DCP). While the dynamic flow through these plexuses is complex and not completely understood, current research points to a hybrid model that includes both parallel and in series components in which blood flows in a predominantly serial direction between the superficial vascular complex (SVC) and deep vascular complex (DVC). Each capillary plexus autoregulates independently, so that under most conditions the retinal vasculature supplies adequate blood flow and oxygen saturation at varying depths despite diverse environmental stressors. When the flow in the deep vascular complex (i.e. ICP and DCP) fails, an ischemic lesion referred to as Paracentral Acute Middle Maculopathy (PAMM) can be identified. PAMM is an optical coherence tomography (OCT) finding defined by the presence of a hyperreflective band at the level of the inner nuclear layer (INL) that indicates INL infarction caused by globally impaired perfusion through the retinal capillary system leading to hypoperfusion of the DVC or specifically the DCP. Patients present with an acute onset paracentral scotoma and typically experience a permanent visual defect. Lesions can be caused by a diverse set of local retinal vascular diseases and systemic disorders. PAMM is a manifestation of the retinal ischemic cascade in which the mildest forms of ischemia develop at the venular end of the DCP, i.e. perivenular PAMM, while more severe forms progress horizontally to diffusely involve the INL, and the most severe forms progress vertically to infarct the inner retina. Management is targeted toward the identification and treatment of related vasculopathic and systemic risk factors.
Collapse
Affiliation(s)
- Jackson Scharf
- Retina Disorders and Ophthalmic Genetics, Stein Eye Institute, University of California Los Angeles, Los Angeles, CA, United States; Vagelos College of Physicians and Surgeons, Columbia University, New York, NY, United States
| | - K Bailey Freund
- Retina Department, Vitreous Retina Macula Consultants of New York, New York, NY, United States
| | - SriniVas Sadda
- Doheny Image Reading Center, Doheny Eye Institute, University of California Los Angeles (UCLA) Affiliated, Los Angeles, CA, United States; Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States
| | - David Sarraf
- Retina Disorders and Ophthalmic Genetics, Stein Eye Institute, University of California Los Angeles, Los Angeles, CA, United States; Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States; Greater Los Angeles VA Healthcare Center, Los Angeles, CA, United States.
| |
Collapse
|
23
|
Song W, Shao W, Yi W, Liu R, Desai M, Ness S, Yi J. Visible light optical coherence tomography angiography (vis-OCTA) facilitates local microvascular oximetry in the human retina. BIOMEDICAL OPTICS EXPRESS 2020; 11:4037-4051. [PMID: 33014584 PMCID: PMC7510897 DOI: 10.1364/boe.395843] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 06/18/2020] [Accepted: 06/22/2020] [Indexed: 05/06/2023]
Abstract
We report herein the first visible light optical coherence tomography angiography (vis-OCTA) for human retinal imaging. Compared to the existing vis-OCT systems, we devised a spectrometer with a narrower bandwidth to increase the spectral power density for OCTA imaging, while retaining the major spectral contrast in the blood. We achieved a 100 kHz A-line rate, the fastest acquisition speed reported so far for human retinal vis-OCT. We rigorously optimized the imaging protocol such that a single acquisition took < 6 seconds with a field of view (FOV) of 3×7.8 mm2. The angiography enables accurate localization of microvasculature down to the capillary level and thus enables oximetry at vessels < 100 µm in diameter. We demonstrated microvascular hemoglobin oxygen saturation (sO2) at the feeding and draining vessels at the perifoveal region. The longitudinal repeatability was assessed by < 5% coefficient of variation (CV). The unique capabilities of our vis-OCTA system may allow studies on the role of microvascular oxygen in various retinal pathologies.
Collapse
Affiliation(s)
- Weiye Song
- Department of Medicine, Boston University School of Medicine, Boston Medical Center, Boston 02118, USA
| | - Wenjun Shao
- Department of Medicine, Boston University School of Medicine, Boston Medical Center, Boston 02118, USA
| | - Wei Yi
- Department of Medicine, Boston University School of Medicine, Boston Medical Center, Boston 02118, USA
| | - Rongrong Liu
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Manishi Desai
- Department of Ophthalmology, Boston University School of Medicine, Boston Medical Center, Boston 02118, USA
| | - Steven Ness
- Department of Ophthalmology, Boston University School of Medicine, Boston Medical Center, Boston 02118, USA
| | - Ji Yi
- Department of Medicine, Boston University School of Medicine, Boston Medical Center, Boston 02118, USA
- Department of Biomedical Engineering, Boston University, Boston 02118, USA
- Department of Electronic and Computer Engineering, Boston University, Boston 02118, USA
| |
Collapse
|
24
|
Retinal capillary oximetry with visible light optical coherence tomography. Proc Natl Acad Sci U S A 2020; 117:11658-11666. [PMID: 32398376 DOI: 10.1073/pnas.1918546117] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Assessing oxygen saturation (sO2) remains challenging but is nonetheless necessary for understanding retinal metabolism. We and others previously achieved oximetry on major retinal vessels and measured the total retinal oxygen metabolic rate in rats using visible-light optical coherence tomography. Here we extend oximetry measurements to capillaries and investigate all three retinal vascular plexuses by amplifying and extracting the spectroscopic signal from each capillary segment under the guidance of optical coherence tomography (OCT) angiography. Using this approach, we measured capillary sO2 in the retinal circulation in rats, demonstrated reproducibility of the results, validated the measurements in superficial capillaries with known perfusion pathways, and determined sO2 responses to hypoxia and hyperoxia in the different retinal capillary beds. OCT capillary oximetry has the potential to provide new insights into the retinal circulation in the normal eye as well as in retinal vascular diseases.
Collapse
|
25
|
Lee J, Jang WH, Shim S, Kim B, Jang WS, Myung JK, Park S, Kim KH. Characterization of early-stage cutaneous radiation injury by using optical coherence tomography angiography. BIOMEDICAL OPTICS EXPRESS 2020; 11:2652-2664. [PMID: 32499950 PMCID: PMC7249837 DOI: 10.1364/boe.387400] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Revised: 03/12/2020] [Accepted: 04/13/2020] [Indexed: 05/09/2023]
Abstract
Cutaneous radiation injury (CRI) is a skin injury caused by exposure to high dose ionizing radiation (IR). Diagnosis and treatment of CRI is difficult due to its initial clinically latent period and the following inflammatory bursts. Early detection of CRI before clinical symptoms will be helpful for effective treatment, and various optical methods have been applied with limitations. Here we show that optical coherence tomography angiography (OCTA) could detect changes in the skin during the latent period in CRI mouse models non-invasively. CRI was induced on the mouse hindlimb with exposure to various IR doses and the injured skin regions were imaged longitudinally by OCTA until the onset of clinical symptoms. OCTA detected several changes in the skin including the skin thickening, the dilation of large blood vessels, and the irregularity in vessel boundaries. Some of OCTA findings were confirmed by histology. The study results showed that OCTA could be used for early CRI detection.
Collapse
Affiliation(s)
- Jungbin Lee
- Department of Mechanical Engineering, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-gu, Pohang, Gyeongbuk 37673, South Korea
| | - Won Hyuk Jang
- Divison of Integrative Biosciences & Biotechnology, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-gu, Pohang, Gyeongbuk 37673, South Korea
| | - Sehwan Shim
- National Radiation Emergency Medical Centre, Korea Cancer Centre Hospital, Korea Institute of Radiological & Medical Sciences (KIRAMS), 75 Nowon-ro, Nowon-gu, Seoul 01812, South Korea
| | - Bumju Kim
- Divison of Integrative Biosciences & Biotechnology, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-gu, Pohang, Gyeongbuk 37673, South Korea
| | - Won-Suk Jang
- Laboratory of Experimental Pathology, Korea Cancer Centre Hospital, Korea Institute of Radiological & Medical Sciences (KIRAMS), 75 Nowon-ro, Nowon-gu, Seoul 01812, South Korea
| | - Jae Kyung Myung
- National Radiation Emergency Medical Centre, Korea Cancer Centre Hospital, Korea Institute of Radiological & Medical Sciences (KIRAMS), 75 Nowon-ro, Nowon-gu, Seoul 01812, South Korea
- Laboratory of Experimental Pathology, Korea Cancer Centre Hospital, Korea Institute of Radiological & Medical Sciences (KIRAMS), 75 Nowon-ro, Nowon-gu, Seoul 01812, South Korea
- Department of Pathology, Korea Cancer Centre Hospital, Korea Institute of Radiological & Medical Sciences (KIRAMS), 75 Nowon-ro, Nowon-gu, Seoul 01812, South Korea
| | - Sunhoo Park
- National Radiation Emergency Medical Centre, Korea Cancer Centre Hospital, Korea Institute of Radiological & Medical Sciences (KIRAMS), 75 Nowon-ro, Nowon-gu, Seoul 01812, South Korea
- Laboratory of Experimental Pathology, Korea Cancer Centre Hospital, Korea Institute of Radiological & Medical Sciences (KIRAMS), 75 Nowon-ro, Nowon-gu, Seoul 01812, South Korea
- Department of Pathology, Korea Cancer Centre Hospital, Korea Institute of Radiological & Medical Sciences (KIRAMS), 75 Nowon-ro, Nowon-gu, Seoul 01812, South Korea
| | - Ki Hean Kim
- Department of Mechanical Engineering, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-gu, Pohang, Gyeongbuk 37673, South Korea
- Divison of Integrative Biosciences & Biotechnology, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-gu, Pohang, Gyeongbuk 37673, South Korea
| |
Collapse
|
26
|
Harper DJ, Konegger T, Augustin M, Schützenberger K, Eugui P, Lichtenegger A, Merkle CW, Hitzenberger CK, Glösmann M, Baumann B. Hyperspectral optical coherence tomography for in vivo visualization of melanin in the retinal pigment epithelium. JOURNAL OF BIOPHOTONICS 2019; 12:e201900153. [PMID: 31334610 PMCID: PMC7065636 DOI: 10.1002/jbio.201900153] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 06/19/2019] [Accepted: 07/18/2019] [Indexed: 05/09/2023]
Abstract
Previous studies for melanin visualization in the retinal pigment epithelium (RPE) have exploited either its absorption properties (using photoacoustic tomography or photothermal optical coherence tomography [OCT]) or its depolarization properties (using polarization sensitive OCT). However, these methods are only suitable when the melanin concentration is sufficiently high. In this work, we present the concept of hyperspectral OCT for melanin visualization in the RPE when the concentration is low. Based on white light OCT, a hyperspectral stack of 27 wavelengths (440-700 nm) was created in post-processing for each depth-resolved image. Owing to the size and shape of the melanin granules in the RPE, the variations in backscattering coefficient as a function of wavelength could be identified-a result which is to be expected from Mie theory. This effect was successfully identified both in eumelanin-containing phantoms and in vivo in the low-concentration Brown Norway rat RPE.
Collapse
Affiliation(s)
- Danielle J. Harper
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| | - Thomas Konegger
- Institute of Chemical Technologies and Analytics, TU WienViennaAustria
| | - Marco Augustin
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| | - Kornelia Schützenberger
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| | - Pablo Eugui
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| | - Antonia Lichtenegger
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| | - Conrad W. Merkle
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| | | | - Martin Glösmann
- Core Facility for Research and TechnologyUniversity of Veterinary MedicineViennaAustria
| | - Bernhard Baumann
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| |
Collapse
|
27
|
Wang TA, Chan MC, Lee HC, Lee CY, Tsai MT. Ultrahigh-resolution optical coherence tomography/angiography with an economic and compact supercontinuum laser. BIOMEDICAL OPTICS EXPRESS 2019; 10:5687-5702. [PMID: 31799040 PMCID: PMC6865110 DOI: 10.1364/boe.10.005687] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Revised: 10/06/2019] [Accepted: 10/07/2019] [Indexed: 05/19/2023]
Abstract
In this study, a Q-switch pumped supercontinuum laser (QS-SCL) is used as a light source for in vivo imaging via ultrahigh-resolution optical coherence tomography and angiography (UHR-OCT/OCTA). For this purpose, an OCT system based on a spectral-domain detection scheme is constructed, and a spectrometer with a spectral range of 635 - 875 nm is designed. The effective full-width at half maximum of spectrum covers 150 nm, and the corresponding axial and transverse resolutions are 2 and 10 µm in air, respectively. The relative intensity noise of the QS-SCL and mode-locked SCL is quantitatively compared. Furthermore, a special processing algorithm is developed to eliminate the intrinsic noise of QS-SCL. This work demonstrates that QS-SCLs can effectively reduce the cost and size of UHR-OCT/OCTA instruments, making clinical applications feasible.
Collapse
Affiliation(s)
- Tai-Ang Wang
- Institute of Photonic System, College of Photonics, National Chiao-Tung University, Tainan City 71150, Taiwan
- The authors contributed equally to this work
| | - Ming-Che Chan
- Institute of Photonic System, College of Photonics, National Chiao-Tung University, Tainan City 71150, Taiwan
- The authors contributed equally to this work
| | - Hsiang-Chieh Lee
- Graduate Institute of Photonics and Optoelectronics, National Taiwan University, 10617, Taiwan
- Department of Electrical Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Cheng-Yu Lee
- Department of Electrical Engineering, Chang Gung University, Taoyuan 33302, Taiwan
| | - Meng-Tsan Tsai
- Department of Electrical Engineering, Chang Gung University, Taoyuan 33302, Taiwan
- Department of Neurosurgery, Chang Gung Memorial Hospital, Linkou, Taoyuan 33305, Taiwan
| |
Collapse
|
28
|
Quantification of total haemoglobin concentrations in human whole blood by spectroscopic visible-light optical coherence tomography. Sci Rep 2019; 9:15115. [PMID: 31641197 PMCID: PMC6806004 DOI: 10.1038/s41598-019-51721-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Accepted: 10/02/2019] [Indexed: 11/08/2022] Open
Abstract
The non-invasive quantification of total haemoglobin concentrations [tHb] is highly desired for the assessment of haematologic disorders in vulnerable patient groups, but invasive blood sampling is still the gold standard in current clinical practice. This work demonstrates the potential of visible-light spectroscopic optical coherence tomography (sOCT) for quantifying the [tHb] in human whole blood. To accurately quantify the [tHb] from the substantial optical attenuation by blood in the visible wavelength range, we used a combination of zero-delay acquisition and focus tracking that ensures optimal system sensitivity at any depth inside the sample. Subsequently, we developed an analysis model to adequately correct for the high scattering contribution by red blood cells to the sOCT signal. We validate our method and compare it to conventional sOCT (without focus tracking and zero-delay acquisition) through ex-vivo measurements on flowing human whole blood, with [tHb] values in the clinical range of 7-23 g/dL. For our method with optimized sensitivity, the measured and expected values correlate well (Pearson correlation coefficient = 0.89, p < 0.01), with a precision of 3.8 g/dL. This is a considerable improvement compared to conventional sOCT (Pearson correlation coefficient = 0.59, p = 0.16; precision of 9.1 g/dL).
Collapse
|
29
|
Pi S, Hormel TT, Wei X, Cepurna W, Camino A, Guo Y, Huang D, Morrison J, Jia Y. Monitoring retinal responses to acute intraocular pressure elevation in rats with visible light optical coherence tomography. NEUROPHOTONICS 2019; 6:041104. [PMID: 31312671 PMCID: PMC6624745 DOI: 10.1117/1.nph.6.4.041104] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Accepted: 06/21/2019] [Indexed: 05/08/2023]
Abstract
Elevated intraocular pressure (IOP) is an important risk factor for glaucoma. However, the role of IOP in glaucoma progression, as well as retinal physiology in general, remains incompletely understood. We demonstrate the use of visible light optical coherence tomography to measure retinal responses to acute IOP elevation in Brown Norway rats. We monitored retinal responses in reflectivity, angiography, blood flow, oxygen saturation ( sO 2 ), and oxygen metabolism over a range of IOP from 10 to 100 mmHg. As IOP was elevated, nerve fiber layer reflectivity was found to decrease. Vascular perfusion in the three retinal capillary plexuses remained steady until IOP exceeded 70 mmHg and arterial flow was noted to reverse periodically at high IOPs. However, a significant drop in total retinal blood flow was observed first at 40 mmHg. As IOP increased, the venous sO 2 demonstrated a gradual decrease despite steady arterial sO 2 , which is consistent with increased arterial-venous oxygen extraction across the retinal capillary beds. Calculated total retinal oxygen metabolism was steady, reflecting balanced responses of blood flow and oxygen extraction, until IOP exceeded 40 mmHg, and fell to 0 at 70 and 80 mmHg. Above this, measurements were unattainable. All measurements reverted to baseline when the IOP was returned to 10 mmHg, indicating good recovery following acute pressure challenge. These results demonstrate the ability of this system to monitor retinal oxygen metabolism noninvasively and how it can help us understand retinal responses to elevated IOP.
Collapse
Affiliation(s)
- Shaohua Pi
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - Tristan T. Hormel
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - Xiang Wei
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - William Cepurna
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - Acner Camino
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - Yukun Guo
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - David Huang
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - John Morrison
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - Yali Jia
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
- Address all correspondence to Yali Jia, E-mail:
| |
Collapse
|
30
|
Beckmann L, Zhang X, Nadkarni NA, Cai Z, Batra A, Sullivan DP, Muller WA, Sun C, Kuranov R, Zhang HF. Longitudinal deep-brain imaging in mouse using visible-light optical coherence tomography through chronic microprism cranial window. BIOMEDICAL OPTICS EXPRESS 2019; 10:5235-5250. [PMID: 31646044 PMCID: PMC6788609 DOI: 10.1364/boe.10.005235] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 09/10/2019] [Accepted: 09/10/2019] [Indexed: 05/02/2023]
Abstract
We longitudinally imaged both the superficial and deep cortical microvascular networks in brains of healthy mice and in a mouse model of stroke in vivo using visible-light optical coherence tomography (vis-OCT). We surgically implanted a microprism in mouse brains sealed by a chronic cranial window. The microprism enabled vis-OCT to image the entire depth of the mouse cortex. Following microprism implantation, we imaged the mice for 28 days and found that that it took around 15 days for both the superficial and deep cortical microvessels to recover from the implantation surgery. After the brains recovered, we introduced ischemic strokes by transient middle cerebral artery occlusion (tMCAO). We monitored the strokes for up to 60 days and observed different microvascular responses to tMCAO at different cortical depths in both the acute and chronic phases of the stroke. This work demonstrates that the combined microprism and cranial window is well-suited for longitudinal investigation of cortical microvascular disorders using vis-OCT.
Collapse
Affiliation(s)
- Lisa Beckmann
- Department of Biomedical Engineering, Northwestern University, Evanston IL 60208, USA
- These authors contributed equally to this work
| | - Xian Zhang
- Department of Biomedical Engineering, Northwestern University, Evanston IL 60208, USA
- Department of Ophthalmology, Tongji Hospital, Tongji Medical College, HuaZhong University of Science and Technology, Wuhan, Hubei, China
- These authors contributed equally to this work
| | - Neil A. Nadkarni
- Department of Neurology, Northwestern University, Chicago IL 60611, USA
| | - Zhen Cai
- Department of Biomedical Engineering, Northwestern University, Evanston IL 60208, USA
- Department of Ophthalmology, Tongji Hospital, Tongji Medical College, HuaZhong University of Science and Technology, Wuhan, Hubei, China
| | - Ayush Batra
- Department of Neurology, Northwestern University, Chicago IL 60611, USA
| | - David P. Sullivan
- Department of Pathology, Northwestern University, Chicago IL 60611, USA
| | - William A. Muller
- Department of Pathology, Northwestern University, Chicago IL 60611, USA
| | - Cheng Sun
- Department of Mechanical Engineering, Northwestern University, Evanston IL 60208, USA
| | - Roman Kuranov
- Department of Biomedical Engineering, Northwestern University, Evanston IL 60208, USA
- Opticent Health, Evanston IL, Evanston IL 60201, USA
| | - Hao F. Zhang
- Department of Biomedical Engineering, Northwestern University, Evanston IL 60208, USA
| |
Collapse
|
31
|
Structural and Functional Sensing of Bio-Tissues Based on Compressive Sensing Spectral Domain Optical Coherence Tomography. SENSORS 2019; 19:s19194208. [PMID: 31569799 PMCID: PMC6807266 DOI: 10.3390/s19194208] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 09/17/2019] [Accepted: 09/24/2019] [Indexed: 11/16/2022]
Abstract
In this paper, a full depth 2D CS-SDOCT approach is proposed, which combines two-dimensional (2D) compressive sensing spectral-domain optical coherence tomography (CS-SDOCT) and dispersion encoding (ED) technologies, and its applications in structural imaging and functional sensing of bio-tissues are studied. Specifically, by introducing a large dispersion mismatch between the reference arm and sample arm in SD-OCT system, the reconstruction of the under-sampled A-scan data and the removal of the conjugated images can be achieved simultaneously by only two iterations. The under-sampled B-scan data is then reconstructed using the classic CS reconstruction algorithm. For a 5 mm × 3.2 mm fish-eye image, the conjugated image was reduced by 31.4 dB using 50% × 50% sampled data (250 depth scans and 480 spectral sampling points per depth scan), and all A-scan data was reconstructed in only 1.2 s. In addition, we analyze the application performance of the CS-SDOCT in functional sensing of locally homogeneous tissue. Simulation and experimental results show that this method can correctly reconstruct the extinction coefficient spectrum under reasonable iteration times. When 8 iterations were used to reconstruct the A-scan data in the imaging experiment of fisheye, the extinction coefficient spectrum calculated using 50% × 50% data was approximately consistent with that obtained with 100% data.
Collapse
|
32
|
Li B, Esipova TV, Sencan I, Kılıç K, Fu B, Desjardins M, Moeini M, Kura S, Yaseen MA, Lesage F, Østergaard L, Devor A, Boas DA, Vinogradov SA, Sakadžić S. More homogeneous capillary flow and oxygenation in deeper cortical layers correlate with increased oxygen extraction. eLife 2019; 8:42299. [PMID: 31305237 PMCID: PMC6636997 DOI: 10.7554/elife.42299] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Accepted: 07/01/2019] [Indexed: 01/01/2023] Open
Abstract
Our understanding of how capillary blood flow and oxygen distribute across cortical layers to meet the local metabolic demand is incomplete. We addressed this question by using two-photon imaging of resting-state microvascular oxygen partial pressure (PO2) and flow in the whisker barrel cortex in awake mice. Our measurements in layers I-V show that the capillary red-blood-cell flux and oxygenation heterogeneity, and the intracapillary resistance to oxygen delivery, all decrease with depth, reaching a minimum around layer IV, while the depth-dependent oxygen extraction fraction is increased in layer IV, where oxygen demand is presumably the highest. Our findings suggest that more homogeneous distribution of the physiological observables relevant to oxygen transport to tissue is an important part of the microvascular network adaptation to local brain metabolism. These results will inform the biophysical models of layer-specific cerebral oxygen delivery and consumption and improve our understanding of the diseases that affect cerebral microcirculation.
Collapse
Affiliation(s)
- Baoqiang Li
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, United States
| | - Tatiana V Esipova
- Department of Biochemistry and Biophysics, University of Pennsylvania, Philadelphia, United States.,Department of Chemistry, University of Pennsylvania, Philadelphia, United States
| | - Ikbal Sencan
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, United States
| | - Kıvılcım Kılıç
- Department of Neurosciences, University of California, San Diego, La Jolla, United States
| | - Buyin Fu
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, United States
| | - Michele Desjardins
- Department of Radiology, University of California, San Diego, La Jolla, United States
| | - Mohammad Moeini
- Institute of Biomedical Engineering, École Polytechnique de Montréal, Montréal, Canada.,Research Centre, Montreal Heart Institute, Montréal, Canada
| | - Sreekanth Kura
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, United States
| | - Mohammad A Yaseen
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, United States
| | - Frederic Lesage
- Institute of Biomedical Engineering, École Polytechnique de Montréal, Montréal, Canada.,Research Centre, Montreal Heart Institute, Montréal, Canada
| | - Leif Østergaard
- Center of Functionally Integrative Neuroscience and MINDLab, Institute of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Anna Devor
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, United States.,Department of Neurosciences, University of California, San Diego, La Jolla, United States.,Department of Radiology, University of California, San Diego, La Jolla, United States
| | - David A Boas
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, United States.,Department of Biomedical Engineering, Boston University, Boston, United States
| | - Sergei A Vinogradov
- Department of Biochemistry and Biophysics, University of Pennsylvania, Philadelphia, United States.,Department of Chemistry, University of Pennsylvania, Philadelphia, United States
| | - Sava Sakadžić
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, United States
| |
Collapse
|
33
|
Zhang T, Kho AM, Srinivasan VJ. Improving visible light OCT of the human retina with rapid spectral shaping and axial tracking. BIOMEDICAL OPTICS EXPRESS 2019; 10:2918-2931. [PMID: 31259062 PMCID: PMC6583340 DOI: 10.1364/boe.10.002918] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 04/30/2019] [Accepted: 04/30/2019] [Indexed: 05/23/2023]
Abstract
Visible light optical coherence tomography (OCT) theoretically provides finer axial resolution than near-infrared OCT for a given wavelength bandwidth. To realize this potential in the human retina in vivo, the unique technical challenges of visible light OCT must be addressed. We introduce three advances to further the performance of visible light OCT in the human retina. First, we incorporate a grating light valve spatial light modulator (GLV-SLM) spectral shaping stage to modify the source spectrum. This enables comfortable subject alignment with a red light spectrum, and image acquisition with a broad "white light" spectrum, shaped to minimize sidelobes. Second, we develop a novel, Fourier transform-free, software axial motion tracking algorithm with fast, magnetically actuated stage to maintain near-optimal axial resolution and sensitivity in the presence of eye motion. Third, we implement spatially dependent numerical dispersion compensation for the first time in the human eye in vivo. In vivo human retinal OCT images clearly show that the inner plexiform layer consists of 3 hyper-reflective bands and 2 hypo-reflective bands, corresponding with the standard anatomical division of the IPL. Wavelength-dependent images of the outer retina suggest that, beyond merely improving the axial resolution, shorter wavelength visible light may also provide unique advantages for visualizing Bruch's membrane.
Collapse
Affiliation(s)
- Tingwei Zhang
- Biomedical Engineering Department, University of California Davis, Davis, California, 95616, USA
| | - Aaron M. Kho
- Biomedical Engineering Department, University of California Davis, Davis, California, 95616, USA
| | - Vivek J. Srinivasan
- Biomedical Engineering Department, University of California Davis, Davis, California, 95616, USA
- Department of Ophthalmology and Vision Science, University of California Davis School of Medicine, Sacramento, California, 95817, USA
| |
Collapse
|
34
|
Shu X, Beckmann L, Wang Y, Rubinoff I, Lucy K, Ishikawa H, Wollstein G, Fawzi AA, Schuman JS, Kuranov RV, Zhang HF. Designing visible-light optical coherence tomography towards clinics. Quant Imaging Med Surg 2019; 9:769-781. [PMID: 31281773 PMCID: PMC6571199 DOI: 10.21037/qims.2019.05.01] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Accepted: 05/04/2019] [Indexed: 12/31/2022]
Abstract
BACKGROUND The capabilities of visible-light optical coherence tomography (vis-OCT) in noninvasive anatomical and functional retinal imaging have been demonstrated by multiple groups in both rodents and healthy human subjects. Translating laboratory prototypes to an integrated clinical-environment-friendly system is required to explore the full potential of vis-OCT in disease management. METHODS We developed and optimized a portable vis-OCT system for human retinal imaging in clinical settings. We acquired raster- and circular-scan images from both healthy and diseased human eyes. RESULTS The new vis-OCT provided high-quality retinal images of both subjects without any known eye diseases and patients with various retinal diseases, including retinal occlusive disease and diabetic retinopathy (DR) over a broad range of ages. CONCLUSIONS A newly designed vis-OCT system is sufficiently optimized to be suited for routine patients' examinations in clinics. Vis-OCT has the potential to add new anatomical and functional imaging capabilities to ophthalmic clinical care.
Collapse
Affiliation(s)
- Xiao Shu
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
| | - Lisa Beckmann
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
| | | | - Ian Rubinoff
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
| | - Katie Lucy
- NYU Langone Eye Center, NYU School of Medicine, New York, NY, USA
| | - Hiroshi Ishikawa
- NYU Langone Eye Center, NYU School of Medicine, New York, NY, USA
| | - Gadi Wollstein
- NYU Langone Eye Center, NYU School of Medicine, New York, NY, USA
| | - Amani A. Fawzi
- Department of Ophthalmology, Northwestern University, Chicago, IL, USA
| | - Joel S. Schuman
- NYU Langone Eye Center, NYU School of Medicine, New York, NY, USA
| | - Roman V. Kuranov
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
- Opticent Health, Evanston, IL, USA
| | - Hao F. Zhang
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
- Department of Ophthalmology, Northwestern University, Chicago, IL, USA
| |
Collapse
|
35
|
Steelman ZA, Ho DS, Chu KK, Wax A. Light scattering methods for tissue diagnosis. OPTICA 2019; 6:479-489. [PMID: 33043100 PMCID: PMC7544148 DOI: 10.1364/optica.6.000479] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Light scattering has become a common biomedical research tool, enabling diagnostic sensitivity to myriad tissue alterations associated with disease. Light-tissue interactions are particularly attractive for diagnostics due to the variety of contrast mechanisms that can be used, including spectral, angle-resolved, and Fourier-domain detection. Photonic diagnostic tools offer further benefit in that they are non-ionizing, non-invasive, and give real-time feedback. In this review, we summarize recent innovations in light scattering technologies, with a focus on clinical achievements over the previous ten years.
Collapse
|
36
|
Kho A, Srinivasan VJ. Compensating spatially dependent dispersion in visible light OCT. OPTICS LETTERS 2019; 44:775-778. [PMID: 30767984 PMCID: PMC6503663 DOI: 10.1364/ol.44.000775] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2018] [Accepted: 01/06/2019] [Indexed: 05/02/2023]
Abstract
Visible light optical coherence tomography (OCT) has recently emerged in retinal imaging, with claims of micrometer-scale axial resolution and multi-color (sub-band) imaging. Here, we show that the large dispersion of optical glass and aqueous media, together with broad optical bandwidths often used in visible light OCT, compromises both of these claims. To rectify this, we introduce the notion of spatially dependent (i.e., depth and transverse position-dependent) dispersion. We use a novel sub-band, sub-image correlation algorithm to estimate spatially dependent dispersion in our 109 nm bandwidth visible light OCT mouse retinal imaging system centered at 587 nm. After carefully compensating spatially dependent dispersion, we achieve delineation of fine outer retinal bands in mouse strains of varying pigmentation. Spatially dependent dispersion correction is critical for broader bandwidths and shorter visible wavelengths.
Collapse
Affiliation(s)
- Aaron Kho
- Department of Biomedical Engineering, University of California, Davis, California 95616, USA
| | - Vivek J. Srinivasan
- Department of Biomedical Engineering, University of California, Davis, California 95616, USA
- Department of Ophthalmology and Vision Science, University of California Davis School of Medicine, Sacramento, California 96817, USA
| |
Collapse
|
37
|
Liu R, Song W, Backman V, Yi J. Quantitative quality-control metrics for in vivo oximetry in small vessels by visible light optical coherence tomography angiography. BIOMEDICAL OPTICS EXPRESS 2019; 10:465-486. [PMID: 30800493 PMCID: PMC6377897 DOI: 10.1364/boe.10.000465] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 12/14/2018] [Accepted: 12/14/2018] [Indexed: 05/23/2023]
Abstract
Biological functions rely on local microvasculature to deliver oxygen and nutrients and carry away metabolic waste. Alterations to local oxygenation levels are manifested in diseases including cancer, diabetes mellitus, etc. The ability to quantify oxygen saturation (sO2) within microvasculature in vivo to assess local tissue oxygenation and metabolic function is highly sought after. Visible light optical coherence tomography (vis-OCT) angiography has shown promise in reaching this goal. However, achieving reliable measurements in small vessels can be challenging due to the reduced contrast and requires data averaging to improve the spectral data quality. Therefore, a method for quality-control of the vis-OCT data from small vessels becomes essential to reject unreliable readings. In this work, we present a quantitative metrics to evaluate the spectral data for a reliable measurement of sO2, including angiography signal to noise ratio (SNR), spectral anomaly detection and discard, and theory-experiment correlation analysis. The thresholds for each quantity can be flexibly adjusted according to different applications and system performance. We used these metrics to measure sO2 of C57BL/6J mouse lower extremity microvasculature and validated it by introducing hyperoxia for expected sO2 changes. After validation, we applied this protocol on C57BL/6J mouse ear microvasculature to conduct in vivo small blood vessel OCT oximetry. This work seeks to standardize the data processing method for in vivo oximetry in small vessels by vis-OCT.
Collapse
Affiliation(s)
- Rongrong Liu
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Weiye Song
- Department of Medicine, Boston University School of Medicine, Boston, MA, 02118, USA
| | - Vadim Backman
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Ji Yi
- Department of Medicine, Boston University School of Medicine, Boston, MA, 02118, USA
| |
Collapse
|
38
|
Winkelmann JA, Eid A, Spicer G, Almassalha LM, Nguyen TQ, Backman V. Spectral contrast optical coherence tomography angiography enables single-scan vessel imaging. LIGHT, SCIENCE & APPLICATIONS 2019; 8:7. [PMID: 30651982 PMCID: PMC6333625 DOI: 10.1038/s41377-018-0117-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Revised: 12/14/2018] [Accepted: 12/15/2018] [Indexed: 05/06/2023]
Abstract
Optical coherence tomography angiography relies on motion for contrast and requires at least two data acquisitions per pointwise scanning location. We present a method termed spectral contrast optical coherence tomography angiography using visible light that relies on the spectral signatures of blood for angiography from a single scan using endogenous contrast. We demonstrate the molecular sensitivity of this method, which enables lymphatic vessel, blood, and tissue discrimination.
Collapse
Affiliation(s)
- James A. Winkelmann
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208 USA
| | - Aya Eid
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208 USA
| | - Graham Spicer
- Department of Chemical and Biological Engineering, Northwestern University, Evanston, IL 60208 USA
| | - Luay M. Almassalha
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208 USA
| | - The-Quyen Nguyen
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208 USA
| | - Vadim Backman
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208 USA
| |
Collapse
|
39
|
Şencan İ, Esipova TV, Yaseen MA, Fu B, Boas DA, Vinogradov SA, Shahidi M, Sakadžić S. Two-photon phosphorescence lifetime microscopy of retinal capillary plexus oxygenation in mice. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-9. [PMID: 30516039 PMCID: PMC6278707 DOI: 10.1117/1.jbo.23.12.126501] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2018] [Accepted: 11/07/2018] [Indexed: 05/23/2023]
Abstract
Impaired oxygen delivery and/or consumption in the retinal tissue underlies the pathophysiology of many retinal diseases. However, the essential tools for measuring oxygen concentration in retinal capillaries and studying oxygen transport to retinal tissue are still lacking. We show that two-photon phosphorescence lifetime microscopy can be used to map absolute partial pressures of oxygen (pO2) in the retinal capillary plexus. Measurements were performed at various retinal depths in anesthetized mice under systemic normoxic and hyperoxic conditions. We used a newly developed two-photon phosphorescent oxygen probe, based on a two-photon absorbing platinum tetraphthalimidoporphyrin, and commercially available optics without correction for optical aberrations of the eye. The transverse and axial distances within the tissue volume were calibrated using a model of the eye's optical system. We believe this is the first demonstration of in vivo depth-resolved imaging of pO2 in retinal capillaries. Application of this method has the potential to advance our understanding of oxygen delivery on the microvascular scale and help elucidate mechanisms underlying various retinal diseases.
Collapse
Affiliation(s)
- İkbal Şencan
- Massachusetts General Hospital, Harvard Medical School, Athinuola A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
| | - Tatiana V. Esipova
- University of Pennsylvania, Departments of Biochemistry and Biophysics and of Chemistry, Philadelphia, Pennsylvania, United States
| | - Mohammad A. Yaseen
- Massachusetts General Hospital, Harvard Medical School, Athinuola A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
| | - Buyin Fu
- Massachusetts General Hospital, Harvard Medical School, Athinuola A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
| | - David A. Boas
- Massachusetts General Hospital, Harvard Medical School, Athinuola A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
- Boston University, Department of Biomedical Engineering, Boston, Massachusetts, United States
| | - Sergei A. Vinogradov
- University of Pennsylvania, Departments of Biochemistry and Biophysics and of Chemistry, Philadelphia, Pennsylvania, United States
| | - Mahnaz Shahidi
- University of Southern California, Departments of Ophthalmology and Biomedical Engineering, Los Angeles, California, United States
| | - Sava Sakadžić
- Massachusetts General Hospital, Harvard Medical School, Athinuola A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
| |
Collapse
|
40
|
Syu JP, Buddhakosai W, Chen SJ, Ke CC, Chiou SH, Kuo WC. Supercontinuum source-based multi-contrast optical coherence tomography for rat retina imaging. BIOMEDICAL OPTICS EXPRESS 2018; 9:6132-6144. [PMID: 31065418 PMCID: PMC6490977 DOI: 10.1364/boe.9.006132] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 10/29/2018] [Accepted: 11/01/2018] [Indexed: 05/06/2023]
Abstract
This study proposed an ultrahigh-resolution multi-contrast optical coherence tomography system integrated with fundus photography for in vivo retinal imaging of rodents. A supercontinuum light source was used in the system, providing an axial resolution of less than 3 µm within 1.8 mm (in the tissue). Three types of tissue contrast based on backscattered intensity, phase retardation, and microvasculature at a capillary level can be simultaneously obtained using the proposed system. Pigmented Long-Evans, non-pigmented (albino) Sprague Dawley, and Royal College of Surgeons rats were imaged and compared. In vivo imaging results were validated with histology.
Collapse
Affiliation(s)
- Jia-Pu Syu
- Institute of Biophotonics, National Yang-Ming University, Taipei 112, Taiwan
| | - Waradee Buddhakosai
- Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Shih-Jen Chen
- Department of Ophthalmology, Taipei Veterans General Hospital, Taiwan
- School of Medicine, National Yang-Ming University, Taiwan
| | - Chang-Chih Ke
- Department and Institute of Pharmacology, National Yang-Ming University, Taipei 112, Taiwan
| | - Shih-Hwa Chiou
- Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan
- Department of Ophthalmology, Taipei Veterans General Hospital, Taiwan
- Department and Institute of Pharmacology, National Yang-Ming University, Taipei 112, Taiwan
- Center For Intelligent Drug Systems and Smart Bio-devices (IDSB), National Chiao Tung University, Hsinchu, Taiwan
| | - Wen-Chuan Kuo
- Institute of Biophotonics, National Yang-Ming University, Taipei 112, Taiwan
- Center For Intelligent Drug Systems and Smart Bio-devices (IDSB), National Chiao Tung University, Hsinchu, Taiwan
| |
Collapse
|
41
|
Hashimoto R, Kurata T, Sekine M, Nakano K, Ohnishi T, Haneishi H. Two-wavelength oximetry of tissue microcirculation based on sidestream dark-field imaging. JOURNAL OF BIOMEDICAL OPTICS 2018; 24:1-8. [PMID: 30378349 PMCID: PMC6975279 DOI: 10.1117/1.jbo.24.3.031013] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Accepted: 10/10/2018] [Indexed: 05/24/2023]
Abstract
Monitoring oxygen saturation (SO2) in microcirculation is effective for understanding disease dynamics. We have developed an SO2 estimation method, sidestream dark-field (SDF) oximetry, based on SDF imaging. SDF imaging is a noninvasive and clinically applicable technique to observe microcirculation. We report the first in vivo experiment observing the changes in SO2 of microcirculation using SDF oximetry. First, heat from the light-emitting diodes used for the SDF imaging might affect hemodynamics in microcirculation, hence, we performed an experiment to evaluate the influence of that on the SDF oximetry. The result suggested that SDF oximetry had enough stability for long-term experiments. Then, to evaluate the sensitivity of SDF oximetry to alterations in the hemodynamics of the microcirculation, we observed the time-lapsed SO2 changes in the dermis microcirculation of rats under hypoxic stimulation. We confirmed that the SO2 estimated by SDF oximetry was in accordance with changes in the fraction of inspired oxygen (FiO2). Thus, SDF oximetry is considered to be able to observe SO2 changes that occur in accordance with alteration of the microcirculation.
Collapse
Affiliation(s)
- Ryohei Hashimoto
- Chiba University, Graduate School of Science and Engineering, Chiba, Japan
| | | | - Masashi Sekine
- Chiba University, Center for Frontier Medical Engineering, Chiba, Japan
| | - Kazuya Nakano
- Chiba University, Center for Frontier Medical Engineering, Chiba, Japan
| | - Takashi Ohnishi
- Chiba University, Center for Frontier Medical Engineering, Chiba, Japan
| | - Hideaki Haneishi
- Chiba University, Center for Frontier Medical Engineering, Chiba, Japan
| |
Collapse
|
42
|
Yi L, Sun L, Ming X, Zou M. Full-depth spectral domain optical coherence tomography technology insensitive to phase disturbance. BIOMEDICAL OPTICS EXPRESS 2018; 9:5071-5083. [PMID: 30319922 PMCID: PMC6179399 DOI: 10.1364/boe.9.005071] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Revised: 09/20/2018] [Accepted: 09/21/2018] [Indexed: 06/08/2023]
Abstract
To achieve full-depth spectral domain optical coherence tomography in the case of strong environmental disturbance, the iterative phase-shifting (IPS) method and modified dispersion-coded (MDC) method are proposed in this work. In IPS, the precise amount of phase shift is retrieved by iteration, and the direction of the phase shift is determined by dispersion compensation. Conjugate mirror items and noise can be simultaneously eliminated by two captured interferograms, whereas only one of them can be removed in the traditional phase-shift method with two interferograms. In MDC, they are removed through dispersion compensation and signal extraction with a single interferogram. Full-depth images of a glass slide, an onion, and a live fish eye are obtained by the two methods. The advantages and disadvantages of each method are analyzed and compared. IPS is found to be more effective for removing conjugate artifacts, whereas MDC is more conducive to real-time imaging. For a 2 mm × 3.6 mm image of a fish eye (200 depth scans and 1200 spectral sampling points per depth scan), the mirror image artifact is reduced by 28.55 dB in MDC and 41.53 dB in IPS. Processing times are 5.1 seconds (20 iterations) for the IPS method and 0.91 seconds for MDC.
Collapse
|
43
|
Gao W. Quantitative depth-resolved microcirculation imaging with optical coherence tomography angiography (Part ΙΙ): Microvascular network imaging. Microcirculation 2018; 25:e12376. [DOI: 10.1111/micc.12376] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2017] [Accepted: 04/11/2017] [Indexed: 11/28/2022]
Affiliation(s)
- Wanrong Gao
- Department of Optical Engineering; Nanjing University of Science and Technology; Nanjing Jiangsu China
- MIIT Key Laboratory of Advanced Solid Laser; Nanjing University of Science and Technology; Nanjing Jiangsu China
| |
Collapse
|
44
|
Veenstra C, Petersen W, Vellekoop IM, Steenbergen W, Bosschaart N. Spatially confined quantification of bilirubin concentrations by spectroscopic visible-light optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2018; 9:3581-3589. [PMID: 30338141 PMCID: PMC6191639 DOI: 10.1364/boe.9.003581] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Revised: 05/09/2018] [Accepted: 06/06/2018] [Indexed: 05/18/2023]
Abstract
Spatially confined measurements of bilirubin in tissue can be of great value for noninvasive bilirubin estimations during neonatal jaundice, as well as our understanding of the physiology behind bilirubin extravasation. This work shows the potential of spectroscopic visible-light optical coherence tomography (sOCT) for this purpose. At the bilirubin absorption peak around 460 nm, sOCT suffers from a strong signal decay with depth, which we overcome by optimizing our system sensitivity through a combination of zero-delay acquisition and focus tracking. In a phantom study, we demonstrate the quantification of bilirubin concentrations between 0 and 650 µM with only a 10% difference to the expected value, thereby covering the entire clinical pathophysiological range.
Collapse
|
45
|
Pi S, Camino A, Cepurna W, Wei X, Zhang M, Huang D, Morrison J, Jia Y. Automated spectroscopic retinal oximetry with visible-light optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2018; 9:2056-2067. [PMID: 29760969 PMCID: PMC5946770 DOI: 10.1364/boe.9.002056] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 03/30/2018] [Accepted: 04/01/2018] [Indexed: 05/18/2023]
Abstract
Accurate, quantitative assessment of retinal blood oxygen saturation (sO2 ) may provide a useful early indicator of pathophysiology in several ocular diseases. Here, with visible-light optical coherence tomography (OCT), we demonstrate an automated spectroscopic retinal oximetry algorithm to measure the sO2 within the retinal arteries (A-sO2 ) and veins (V-sO2 ) in rats by automatically detecting the vascular posterior boundary on cross-sectional structural OCT. The algorithm was validated in vitro with flow phantoms and in vivo in rats by comparing the sO2 results, respectively, to those obtained using a blood gas analyzer and pulse oximetry. We also investigated the response of oxygen extraction (A-V sO2 ), including inter-session reproducibility, at different inhaled oxygen concentrations.
Collapse
Affiliation(s)
- Shaohua Pi
- Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA
| | - Acner Camino
- Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA
| | - William Cepurna
- Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA
| | - Xiang Wei
- Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA
| | - Miao Zhang
- Optovue Inc. 2800 Bayview Dr., Fremont, CA 94538, USA
| | - David Huang
- Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA
| | - John Morrison
- Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA
| | - Yali Jia
- Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA
| |
Collapse
|
46
|
Harper DJ, Augustin M, Lichtenegger A, Eugui P, Reyes C, Glösmann M, Hitzenberger CK, Baumann B. White light polarization sensitive optical coherence tomography for sub-micron axial resolution and spectroscopic contrast in the murine retina. BIOMEDICAL OPTICS EXPRESS 2018; 9:2115-2129. [PMID: 29760974 PMCID: PMC5946775 DOI: 10.1364/boe.9.002115] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2018] [Revised: 03/29/2018] [Accepted: 03/30/2018] [Indexed: 05/03/2023]
Abstract
A white light polarization sensitive optical coherence tomography system has been developed, using a supercontinuum laser as the light source. By detecting backscattered light from 400 - 700 nm, an axial resolution of 1.0 µm in air was achieved. The system consists of a free-space interferometer and two homemade spectrometers that detect orthogonal polarization states. Following system specifications, images of a healthy murine retina as acquired by this non-contact system are presented, showing high resolution reflectivity images as well as spectroscopic and polarization sensitive contrast. Additional images of the very-low-density-lipoprotein-receptor (VLDLR) knockout mouse model were acquired. The high resolution allows the detection of small lesions in the retina.
Collapse
Affiliation(s)
- Danielle J. Harper
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| | - Marco Augustin
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| | - Antonia Lichtenegger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| | - Pablo Eugui
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| | - Carlos Reyes
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| | - Martin Glösmann
- University of Veterinary Medicine Vienna, Core Facility for Research and Technology, Veterinaerplatz 1, 1210 Vienna,
Austria
| | - Christoph K. Hitzenberger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| | - Bernhard Baumann
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| |
Collapse
|
47
|
Chong SP, Zhang T, Kho A, Bernucci MT, Dubra A, Srinivasan VJ. Ultrahigh resolution retinal imaging by visible light OCT with longitudinal achromatization. BIOMEDICAL OPTICS EXPRESS 2018; 9:1477-1491. [PMID: 29675296 PMCID: PMC5905900 DOI: 10.1364/boe.9.001477] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Revised: 01/30/2018] [Accepted: 02/03/2018] [Indexed: 05/18/2023]
Abstract
Chromatic aberrations are an important design consideration in high resolution, high bandwidth, refractive imaging systems that use visible light. Here, we present a fiber-based spectral/Fourier domain, visible light OCT ophthalmoscope corrected for the average longitudinal chromatic aberration (LCA) of the human eye. Analysis of complex speckles from in vivo retinal images showed that achromatization resulted in a speckle autocorrelation function that was ~20% narrower in the axial direction, but unchanged in the transverse direction. In images from the improved, achromatized system, the separation between Bruch's membrane (BM), the retinal pigment epithelium (RPE), and the outer segment tips clearly emerged across the entire 6.5 mm field-of-view, enabling segmentation and morphometry of BM and the RPE in a human subject. Finally, cross-sectional images depicted distinct inner retinal layers with high resolution. Thus, with chromatic aberration compensation, visible light OCT can achieve volume resolutions and retinal image quality that matches or exceeds ultrahigh resolution near-infrared OCT systems with no monochromatic aberration compensation.
Collapse
Affiliation(s)
- Shau Poh Chong
- Biomedical Engineering Department, University of California Davis, Davis, CA 95616, USA
- Equal contributions
| | - Tingwei Zhang
- Biomedical Engineering Department, University of California Davis, Davis, CA 95616, USA
- Equal contributions
| | - Aaron Kho
- Biomedical Engineering Department, University of California Davis, Davis, CA 95616, USA
| | - Marcel T. Bernucci
- Biomedical Engineering Department, University of California Davis, Davis, CA 95616, USA
| | - Alfredo Dubra
- Byers Eye Institute, Stanford University, Palo Alto, CA 94303, USA
| | - Vivek J. Srinivasan
- Biomedical Engineering Department, University of California Davis, Davis, CA 95616, USA
- Department of Ophthalmology and Vision Science, University of California Davis School of Medicine, Sacramento, CA 95817, USA
| |
Collapse
|
48
|
Marchand PJ, Szlag D, Bouwens A, Lasser T. In vivo high-resolution cortical imaging with extended-focus optical coherence microscopy in the visible-NIR wavelength range. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-7. [PMID: 29575831 DOI: 10.1117/1.jbo.23.3.036012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Accepted: 03/07/2018] [Indexed: 05/10/2023]
Abstract
Visible light optical coherence tomography has shown great interest in recent years for spectroscopic and high-resolution retinal and cerebral imaging. Here, we present an extended-focus optical coherence microscopy system operating from the visible to the near-infrared wavelength range for high axial and lateral resolution imaging of cortical structures in vivo. The system exploits an ultrabroad illumination spectrum centered in the visible wavelength range (λc = 650 nm, Δλ ∼ 250 nm) offering a submicron axial resolution (∼0.85 μm in water) and an extended-focus configuration providing a high lateral resolution of ∼1.4 μm maintained over ∼150 μm in depth in water. The system's axial and lateral resolution are first characterized using phantoms, and its imaging performance is then demonstrated by imaging the vasculature, myelinated axons, and neuronal cells in the first layers of the somatosensory cortex of mice in vivo.
Collapse
Affiliation(s)
- Paul J Marchand
- Ecole Polytechnique Fédérale de Lausanne, Laboratoire d' Optique Biomédicale, Lausanne, Switzerland
| | - Daniel Szlag
- Ecole Polytechnique Fédérale de Lausanne, Laboratoire d' Optique Biomédicale, Lausanne, Switzerland
| | - Arno Bouwens
- Ecole Polytechnique Fédérale de Lausanne, Laboratoire d' Optique Biomédicale, Lausanne, Switzerland
| | - Theo Lasser
- Ecole Polytechnique Fédérale de Lausanne, Laboratoire d' Optique Biomédicale, Lausanne, Switzerland
| |
Collapse
|
49
|
Abstract
The microvasculature plays a central role in the pathophysiology of hemorrhagic shock and is also involved in arguably all therapeutic attempts to reverse or minimize the adverse consequences of shock. Microvascular studies specific to hemorrhagic shock were reviewed and broadly grouped depending on whether data were obtained on animal or human subjects. Dedicated sections were assigned to microcirculatory changes in specific organs, and major categories of pathophysiological alterations and mechanisms such as oxygen distribution, ischemia, inflammation, glycocalyx changes, vasomotion, endothelial dysfunction, and coagulopathy as well as biomarkers and some therapeutic strategies. Innovative experimental methods were also reviewed for quantitative microcirculatory assessment as it pertains to changes during hemorrhagic shock. The text and figures include representative quantitative microvascular data obtained in various organs and tissues such as skin, muscle, lung, liver, brain, heart, kidney, pancreas, intestines, and mesentery from various species including mice, rats, hamsters, sheep, swine, bats, and humans. Based on reviewed findings, a new integrative conceptual model is presented that includes about 100 systemic and local factors linked to microvessels in hemorrhagic shock. The combination of systemic measures with the understanding of these processes at the microvascular level is fundamental to further develop targeted and personalized interventions that will reduce tissue injury, organ dysfunction, and ultimately mortality due to hemorrhagic shock. Published 2018. Compr Physiol 8:61-101, 2018.
Collapse
Affiliation(s)
- Ivo Torres Filho
- US Army Institute of Surgical Research, JBSA Fort Sam Houston, Texas, USA
| |
Collapse
|
50
|
Shu X, Beckmann L, Zhang HF. Visible-light optical coherence tomography: a review. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-14. [PMID: 29218923 PMCID: PMC5745673 DOI: 10.1117/1.jbo.22.12.121707] [Citation(s) in RCA: 74] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Accepted: 11/13/2017] [Indexed: 05/03/2023]
Abstract
Visible-light optical coherence tomography (vis-OCT) is an emerging imaging modality, providing new capabilities in both anatomical and functional imaging of biological tissue. It relies on visible light illumination, whereas most commercial and investigational OCTs use near-infrared light. As a result, vis-OCT requires different considerations in engineering design and implementation but brings unique potential benefits to both fundamental research and clinical care of several diseases. Here, we intend to provide a summary of the development of vis-OCT and its demonstrated applications. We also provide perspectives on future technology improvement and applications.
Collapse
Affiliation(s)
- Xiao Shu
- Northwestern University, Department of Biomedical Engineering, Evanston, Illinois, United States
| | - Lisa Beckmann
- Northwestern University, Department of Biomedical Engineering, Evanston, Illinois, United States
| | - Hao F. Zhang
- Northwestern University, Department of Biomedical Engineering, Evanston, Illinois, United States
- Northwestern University, Department of Ophthalmology, Chicago, Illinois, United States
- Address all correspondence to: Hao F. Zhang, E-mail:
| |
Collapse
|