1
|
Gao YN, Yang HT, Qiu ZF, Qi F, Lu QH, Zheng JF, Xi ZW, Wang X, Li L, Zhang G, Zhang DY, Lu YD, Qi HP, Qiu H, Gao RL, Zheng YF. Long-term efficacy, safety and biocompatibility of a novel sirolimus eluting iron bioresorbable scaffold in a porcine model. Bioact Mater 2024; 39:135-146. [PMID: 38783928 PMCID: PMC11112549 DOI: 10.1016/j.bioactmat.2024.05.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2024] [Revised: 04/19/2024] [Accepted: 05/13/2024] [Indexed: 05/25/2024] Open
Abstract
Iron is considered as an attractive alternative material for bioresorbable scaffolds (BRS). The sirolimus eluting iron bioresorbable scaffold (IBS), developed by Biotyx Medical (Shenzhen, China), is the only iron-based BRS with an ultrathin-wall design. The study aims to investigate the long-term efficacy, safety, biocompatibility, and lumen changes during the biodegradation process of the IBS in a porcine model. A total of 90 IBSs and 70 cobalt-chromium everolimus eluting stents (EES) were randomly implanted into nonatherosclerotic coronary artery of healthy mini swine. The multimodality assessments including coronary angiography, optical coherence tomography, micro-computed tomography, magnetic resonance imaging, real-time polymerase chain reaction (PCR), and histopathological evaluations, were performed at different time points. There was no statistical difference in area stenosis between IBS group and EES group at 6 months, 1year, 2 years and 5 years. Although the scaffolded vessels narrowed at 9 months, expansive remodeling with increased mean lumen area was found at 3 and 5 years. The IBS struts remained intact at 6 months, and the corrosion was detectable at 9 months. At 5 years, the iron struts were completely degraded and absorbed in situ, without in-scaffold restenosis or thrombosis, lumen collapse, aneurysm formation, and chronic inflammation. No local or systemic toxicity and abnormal histopathologic manifestation were found in all experiments. Results from real-time PCR indicated that no sign of iron overload was reported in scaffolded segments. Therefore, the IBS shows comparable efficacy, safety, and biocompatibility with EES, and late lumen enlargement is considered as a unique feature in the IBS-implanted vessels.
Collapse
Affiliation(s)
- Ya-Nan Gao
- Department of Cardio-Metabolic Medicine Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Hong-Tao Yang
- School of Engineering Medicine, Beihang University, Beijing, China
| | - Zi-Feng Qiu
- Peking University Health Science Center, Beijing, China
| | - Feng Qi
- Department of Cardiology, Fuwai Yunnan Hospital, Chinese Academy of Medical Sciences, Affiliated Cardiovascular Hospital of Kunming Medical University, Kunming, China
| | - Qian-Hong Lu
- Department of Cardiology, Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jian-Feng Zheng
- Department of Cardiology, Beijing Tsinghua Changgung Hospital, Beijing, China
| | - Zi-Wei Xi
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing, China
| | - Xin Wang
- Beijing Key Laboratory of Pre-clinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Li Li
- Department of Pathology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Gui Zhang
- R&D Center, Biotyx Medical (Shenzhen) Co. Ltd., Shenzhen, China
| | - De-Yuan Zhang
- R&D Center, Biotyx Medical (Shenzhen) Co. Ltd., Shenzhen, China
| | - Yu-Die Lu
- R&D Center, Biotyx Medical (Shenzhen) Co. Ltd., Shenzhen, China
| | - Hai-Ping Qi
- R&D Center, Biotyx Medical (Shenzhen) Co. Ltd., Shenzhen, China
| | - Hong Qiu
- Department of Cardio-Metabolic Medicine Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Run-Lin Gao
- Department of Cardiology, Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yu-Feng Zheng
- School of Materials Science and Engineering, Peking University, Beijing, China
| |
Collapse
|
2
|
Chlupac J, Frank J, Sedmera D, Fabian O, Simunkova Z, Mrazova I, Novak T, Vanourková Z, Benada O, Pulda Z, Adla T, Kveton M, Lodererova A, Voska L, Pirk J, Fronek J. External Support of Autologous Internal Jugular Vein Grafts with FRAME Mesh in a Porcine Carotid Artery Model. Biomedicines 2024; 12:1335. [PMID: 38927542 PMCID: PMC11201386 DOI: 10.3390/biomedicines12061335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 05/28/2024] [Accepted: 06/12/2024] [Indexed: 06/28/2024] Open
Abstract
BACKGROUND Autologous vein grafts are widely used for bypass procedures in cardiovascular surgery. However, these grafts are susceptible to failure due to vein graft disease. Our study aimed to evaluate the impact of the latest-generation FRAME external support on vein graft remodeling in a preclinical model. METHODS We performed autologous internal jugular vein interposition grafting in porcine carotid arteries for one month. Four grafts were supported with a FRAME mesh, while seven unsupported grafts served as controls. The conduits were examined through flowmetry, angiography, macroscopy, and microscopy. RESULTS The one-month patency rate of FRAME-supported grafts was 100% (4/4), whereas that of unsupported controls was 43% (3/7, Log-rank p = 0.071). On explant angiography, FRAME grafts exhibited significantly more areas with no or mild stenosis (9/12) compared to control grafts (3/21, p = 0.0009). Blood flow at explantation was higher in the FRAME grafts (145 ± 51 mL/min) than in the controls (46 ± 85 mL/min, p = 0.066). Area and thickness of neo-intimal hyperplasia (NIH) at proximal anastomoses were similar for the FRAME and the control groups: 5.79 ± 1.38 versus 6.94 ± 1.10 mm2, respectively (p = 0.558) and 480 ± 95 vs. 587 ± 52 μm2/μm, respectively (p = 0.401). However, in the midgraft portions, the NIH area and thickness were significantly lower in the FRAME group than in the control group: 3.73 ± 0.64 vs. 6.27 ± 0.64 mm2, respectively (p = 0.022) and 258 ± 49 vs. 518 ± 36 μm2/μm, respectively (p = 0.0002). CONCLUSIONS In our porcine model, the external mesh FRAME improved the patency of vein-to-carotid artery grafts and protected them from stenosis, particularly in the mid regions. The midgraft neo-intimal hyperplasia was two-fold thinner in the meshed grafts than in the controls.
Collapse
Affiliation(s)
- Jaroslav Chlupac
- Transplantation Surgery Department, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (J.F.); (T.N.); (J.F.)
- Department of Anatomy, Second Faculty of Medicine, Charles University, V Uvalu 84, 150 06 Prague, Czech Republic
| | - Jan Frank
- Transplantation Surgery Department, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (J.F.); (T.N.); (J.F.)
| | - David Sedmera
- Institute of Anatomy, First Faculty of Medicine, Charles University, U Nemocnice 3, Praha 2, 128 00 Prague, Czech Republic;
| | - Ondrej Fabian
- Clinical and Transplant Pathology Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (O.F.); (M.K.); (A.L.); (L.V.)
- Department of Pathology and Molecular Medicine, Third Faculty of Medicine, Charles University, and Thomayer University Hospital, Ruska 87, 100 00 Prague, Czech Republic
| | - Zuzana Simunkova
- Experimental Medicine Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (Z.S.); (I.M.); (Z.V.)
| | - Iveta Mrazova
- Experimental Medicine Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (Z.S.); (I.M.); (Z.V.)
| | - Tomas Novak
- Transplantation Surgery Department, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (J.F.); (T.N.); (J.F.)
| | - Zdenka Vanourková
- Experimental Medicine Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (Z.S.); (I.M.); (Z.V.)
| | - Oldrich Benada
- Laboratory of Molecular Structure Characterization, Institute of Microbiology of the Czech Academy of Sciences, Vídeňská 1083, 142 00 Prague, Czech Republic;
| | - Zdenek Pulda
- Department of Imaging Methods, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (Z.P.); (T.A.)
| | - Theodor Adla
- Department of Imaging Methods, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (Z.P.); (T.A.)
| | - Martin Kveton
- Clinical and Transplant Pathology Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (O.F.); (M.K.); (A.L.); (L.V.)
- Third Faculty of Medicine, Charles University, Ruska 87, 100 00 Prague, Czech Republic
| | - Alena Lodererova
- Clinical and Transplant Pathology Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (O.F.); (M.K.); (A.L.); (L.V.)
| | - Ludek Voska
- Clinical and Transplant Pathology Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (O.F.); (M.K.); (A.L.); (L.V.)
| | - Jan Pirk
- Cardiovascular Surgery Department, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic;
| | - Jiri Fronek
- Transplantation Surgery Department, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (J.F.); (T.N.); (J.F.)
- Department of Anatomy, Second Faculty of Medicine, Charles University, V Uvalu 84, 150 06 Prague, Czech Republic
- First Surgical Clinic, First Faculty of Medicine, Charles University, U Nemocnice 499/2, 128 08 Prague, Czech Republic
| |
Collapse
|
3
|
Long-term safety and absorption assessment of a novel bioresorbable nitrided iron scaffold in porcine coronary artery. Bioact Mater 2022; 17:496-505. [PMID: 35415293 PMCID: PMC8976101 DOI: 10.1016/j.bioactmat.2022.01.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 12/20/2021] [Accepted: 01/04/2022] [Indexed: 12/18/2022] Open
Abstract
This study aimed to investigate the long-term biocompatibility, safety, and degradation of the ultrathin nitrided iron bioresorbable scaffold (BRS) in vivo, encompassing the whole process of bioresorption in porcine coronary arteries. Fifty-two nitrided iron scaffolds (strut thickness of 70 μm) and 28 Vision Co–Cr stents were randomly implanted into coronary arteries of healthy mini-swine. The efficacy and safety of the nitrided iron scaffold were comparable with those of the Vision stentwithin 52 weeks after implantation. In addition, the long-term biocompatibility, safety, and bioresorption of the nitrided iron scaffold were evaluated by coronary angiography, optical coherence tomography, micro-computed tomography, scanning electron microscopy, energy dispersive spectrometry and histopathological evaluations at 4, 12, 26, 52 weeks and even at 7 years after implantation. In particular, a large number of struts were almost completely absorbed in situ at 7 years follow-up, which were first illustrated in this study. The lymphatic drainage pathway might serve as the potential clearance way of iron and its corrosion products. This study investigated the long-term safety and the total degradative process of nitrided iron scaffold in porcine coronary artery. The safety and biocompatibility of the nitrided iron scaffold were comparable to those of the Vision stent within 12 months after implantation. This ultrathin nitrided iron scaffold can be degraded and bioresorbed completely with long-term biocompatibility in porcine coronary artery. Interestingly, the lymphatic metabolic pathway might serve as the potential absorption route for iron and its corrosion products.
Collapse
|
4
|
Maleszewski JJ, Lai CK, Nair V, Veinot JP. Anatomic considerations and examination of cardiovascular specimens (excluding devices). Cardiovasc Pathol 2022. [DOI: 10.1016/b978-0-12-822224-9.00013-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
5
|
Kitano D, Migita S, Li Y, Takahashi R, Taniguchi Y, Kurosawa T, Sudo M, Haruta H, Hiro T, Takayama T, Mitsumata M, Matsumoto T, Okumura Y, Hirayama A. Effect of Rivaroxaban and Clopidogrel Combination Therapy on In-Stent Responses After Everolimus-Eluting Stent Implantation in a Porcine Coronary Model. J Atheroscler Thromb 2022; 29:69-81. [PMID: 33208566 PMCID: PMC8737068 DOI: 10.5551/jat.56549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Accepted: 10/05/2020] [Indexed: 12/02/2022] Open
Abstract
AIM According to recent clinical trials, a combination of direct oral anticoagulants with antiplatelet drugs is often recommended for atrial fibrillation patients who receive drug-eluting stents (DESs). Although the optimal combination comprises direct factor Xa inhibitors and a P2Y12 receptor antagonist (or aspirin), their influence on vascular responses to DESs remains unclear. METHODS Pigs were given either aspirin and clopidogrel (dual antiplatelet therapy [DAPT] group), aspirin and rivaroxaban (AR group), or clopidogrel and rivaroxaban (CR group), followed by everolimus-eluting stent (Promus Element) implantation into the coronary artery. Stented coronary arteries were evaluated via intravascular optical coherence tomography (OCT) and histological analysis at 1 and 3 months. RESULTS OCT revealed lower neointimal thickness in the DAPT group and comparable thickness among all groups at 1 and 3 months, respectively. Histological analyses revealed comparable neointimal area among all groups and the smallest neointimal area in the CR group at 1 and 3 months, respectively. In the DAPT and AR groups, the neointima continued to grow from 1 to 3 months. A shortened time course for neointima growth was observed in the CR group, with rapid growth within a month (maintained for 3 months). A higher incidence of in-stent thrombi was observed in the AR group at 1 month; no thrombi were found in either group at 3 months. More smooth muscle cells with contractile features were found in the CR group at both 1 and 3 months. CONCLUSIONS Our results proved the noninferiority of the combination of rivaroxaban with an antiplatelet drug, particularly the dual therapy using rivaroxaban and clopidogrel, compared to DAPT after DES implantation.
Collapse
Affiliation(s)
- Daisuke Kitano
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
- Division of Advanced Cardiovascular Imaging, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Suguru Migita
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Yuxin Li
- Division of Advanced Cardiovascular Imaging, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
- Division of Cell Regeneration and Transplantation, Department of Functional Morphology, Nihon University School of Medicine, Tokyo, Japan
| | - Rie Takahashi
- Research Support Center, Research Institute of Medical Science, Nihon University School of Medicine, Tokyo, Japan
| | - Yoshiki Taniguchi
- Research Support Center, Research Institute of Medical Science, Nihon University School of Medicine, Tokyo, Japan
| | - Takafumi Kurosawa
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Mitsumasa Sudo
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
- Division of Advanced Cardiovascular Imaging, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Hironori Haruta
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Takafumi Hiro
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
- Division of Advanced Cardiovascular Imaging, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Tadateru Takayama
- Department of General Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Masako Mitsumata
- Division of Pathology, Central Clinical Laboratory, Yamanashi Kosei Hospital, Yamanashi, Japan
| | - Taro Matsumoto
- Division of Cell Regeneration and Transplantation, Department of Functional Morphology, Nihon University School of Medicine, Tokyo, Japan
| | - Yasuo Okumura
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Atsushi Hirayama
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
- Cardiovascular Division, Osaka Police Hospital, Osaka, Japan
| |
Collapse
|
6
|
Kuznetsov KA, Murashov IS, Chernonosova VS, Chelobanov BP, Stepanova AO, Sergeevichev DS, Karpenko AA, Laktionov PP. Vascular Stents Coated with Electrospun Drug-Eluting Material: Functioning in Rabbit Iliac Artery. Polymers (Basel) 2020; 12:polym12081741. [PMID: 32759856 PMCID: PMC7465440 DOI: 10.3390/polym12081741] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 07/31/2020] [Accepted: 08/02/2020] [Indexed: 12/27/2022] Open
Abstract
A stenting procedure aimed at blood flow restoration in stenosed arteries significantly improves the efficiency of vascular surgery. However, the current challenge is to prevent neointimal growth, which reduces the vessel lumen, in the stented segments in the long run. We tested in vivo drug-eluting coating applied by electrospinning to metal vascular stents to inhibit the overgrowth of neointimal cells via both the drug release and mechanical support of the vascular wall. The blend of polycaprolactone with human serum albumin and paclitaxel was used for stent coating by electrospinning. The drug-eluting stents (DESs) were placed using a balloon catheter to the rabbit common iliac artery for 1, 3, and 6 months. The blood flow rate was ultrasonically determined in vivo. After explantation, the stented arterial segment was visually and histologically examined. Any undesirable biological responses (rejection or hemodynamically significant stenosis) were unobservable in the experimental groups. DESs were less traumatic and induced weaker neointimal growth; over six months, the blood flow increased by 37% versus bare-metal stents, where it increased by at least double the rate. Thus, electrospun-coated DESs demonstrate considerable advantages over the bare-metal variants.
Collapse
Affiliation(s)
- Konstantin A. Kuznetsov
- Institute of Chemical Biology and Fundamental Medicine, Siberian Branch, Russian Academy of Sciences, 630090 Novosibirsk, Russia; (V.S.C.); (B.P.C.); (A.O.S.); (P.P.L.)
- City Clinical Hospital no. 1, 630047 Novosibirsk, Russia
- Correspondence: ; Tel.: +7-(383)-363-51-44
| | - Ivan S. Murashov
- Meshalkin National Medical Research Center, Ministry of Health of the Russian Federation, 630055 Novosibirsk, Russia; (I.S.M.); (D.S.S.); (A.A.K.)
| | - Vera S. Chernonosova
- Institute of Chemical Biology and Fundamental Medicine, Siberian Branch, Russian Academy of Sciences, 630090 Novosibirsk, Russia; (V.S.C.); (B.P.C.); (A.O.S.); (P.P.L.)
- Meshalkin National Medical Research Center, Ministry of Health of the Russian Federation, 630055 Novosibirsk, Russia; (I.S.M.); (D.S.S.); (A.A.K.)
| | - Boris P. Chelobanov
- Institute of Chemical Biology and Fundamental Medicine, Siberian Branch, Russian Academy of Sciences, 630090 Novosibirsk, Russia; (V.S.C.); (B.P.C.); (A.O.S.); (P.P.L.)
| | - Alena O. Stepanova
- Institute of Chemical Biology and Fundamental Medicine, Siberian Branch, Russian Academy of Sciences, 630090 Novosibirsk, Russia; (V.S.C.); (B.P.C.); (A.O.S.); (P.P.L.)
- Meshalkin National Medical Research Center, Ministry of Health of the Russian Federation, 630055 Novosibirsk, Russia; (I.S.M.); (D.S.S.); (A.A.K.)
| | - David S. Sergeevichev
- Meshalkin National Medical Research Center, Ministry of Health of the Russian Federation, 630055 Novosibirsk, Russia; (I.S.M.); (D.S.S.); (A.A.K.)
| | - Andrey A. Karpenko
- Meshalkin National Medical Research Center, Ministry of Health of the Russian Federation, 630055 Novosibirsk, Russia; (I.S.M.); (D.S.S.); (A.A.K.)
| | - Pavel P. Laktionov
- Institute of Chemical Biology and Fundamental Medicine, Siberian Branch, Russian Academy of Sciences, 630090 Novosibirsk, Russia; (V.S.C.); (B.P.C.); (A.O.S.); (P.P.L.)
- Meshalkin National Medical Research Center, Ministry of Health of the Russian Federation, 630055 Novosibirsk, Russia; (I.S.M.); (D.S.S.); (A.A.K.)
| |
Collapse
|
7
|
Zheng JF, Qiu H, Tian Y, Hu XY, Luo T, Wu C, Tian Y, Tang Y, Song LF, Li L, Xu L, Xu B, Gao RL. Preclinical Evaluation of a Novel Sirolimus-Eluting Iron Bioresorbable Coronary Scaffold in Porcine Coronary Artery at 6 Months. JACC Cardiovasc Interv 2020; 12:245-255. [PMID: 30732729 DOI: 10.1016/j.jcin.2018.10.020] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 09/30/2018] [Accepted: 10/09/2018] [Indexed: 12/21/2022]
Abstract
OBJECTIVES The aim of this study was to investigate the operability, 6-month efficacy, and safety of the novel sirolimus-eluting iron bioresorbable coronary scaffold (IBS) system compared with a cobalt-chromium everolimus-eluting stent (EES) (XIENCE Prime stent) in porcine coronary arteries. BACKGROUND Bioresorbable scaffolds have been considered the fourth revolution in percutaneous coronary intervention. However, the first-generation bioresorbable scaffold showed suboptimal results. METHODS Forty-eight IBS and 48 EES were randomly implanted into nonatherosclerotic swine. The operability, efficacy, and safety of the IBS and EES were evaluated using coronary angiography, optical coherence tomography, micro-computed tomography, scanning electron microscopy, and histopathologic evaluation at 7, 14, 28, 90, and 180 days after implantation. RESULTS The operability of the ultrathin IBS (∼70 μm) was comparable with that of the EES, except for its visibility. There was no statistically significant difference in area stenosis between the IBS and EES from 28 to 180 days. The IBS maintained its integrity up to 90 days without corrosion, while corrosion was observed in a few struts in 2 of 10 IBS at 180 days. The percentage of endothelialization of IBS was higher than that of XIENCE Prime stents within 14 days after implantation. The fibrin score was higher in the IBS group at 28 days but comparable with the EES group at 90 and 180 days. No scaffold or stent thrombosis was seen in either group. No abnormal histopathologic changes in scaffolded or stented vessel segments and 5 main remote organs were observed in either group. CONCLUSIONS Preclinical results suggest that the novel IBS has comparable operability, mid-term efficacy, and safety with the EES, and its corrosion profile in porcine coronary arteries is reasonable, which could support initial clinical study of the IBS.
Collapse
Affiliation(s)
- Jian-Feng Zheng
- Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China
| | - Hong Qiu
- Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China.
| | - Yuan Tian
- Urumqi Friendship Hospital, Urumqi, Xinjiang Uygur Autonomous Region, China
| | - Xiao-Ying Hu
- Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China
| | - Tong Luo
- Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China
| | - Chao Wu
- Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China
| | - Yi Tian
- Beijing Key Laboratory of Preclinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China
| | - Yue Tang
- Beijing Key Laboratory of Preclinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China
| | - Lai-Feng Song
- Department of Pathology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China
| | - Li Li
- Department of Pathology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China
| | - Liang Xu
- Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China
| | - Bo Xu
- Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China
| | - Run-Lin Gao
- Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Beijing, China.
| |
Collapse
|
8
|
Gayoso J, Garrosa M, Gayoso S, Rodríguez-Arias CA, Martin-Ferrero MÁ, Gayoso MJ. Three-sectioning method: A procedure for studying hard tissues and large pieces under light and electron microscopy. Micron 2020; 132:102841. [PMID: 32062296 DOI: 10.1016/j.micron.2020.102841] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 01/24/2020] [Accepted: 01/24/2020] [Indexed: 11/16/2022]
Abstract
The histological study of hard pieces such as tendons and calcified lesions and tissues is a field that has been gaining increased attention owing to the rapid development of implantable prostheses, among other factors. In these studies, serial sectioning is utilized to detect areas of interest throughout the entire piece, as it enables the application of the appropriate light and electron microscopy techniques in these areas. We propose the "three-sectioning method" that subjects the pieces to three consecutive cycles of embedding and sectioning to localize and study the areas of interest, as an efficient technique for these histological studies. The pieces were first embedded in epoxy resin and then cut into thick sections (approximately 300 μm) for the first cycle. Next, areas of interest selected on these thick sections were re-embedded in epoxy resin to be sectioned again (second sectioning) to obtain a series of semithin sections (1-3 μm). These semithin sections are usually studied using the most relevant techniques for light microscopy. Smaller areas of interest are selected to be cut into ultrathin sections (60-90 nm) for transmission electron microscopy. If necessary, the selected areas of the semithin sections can be embedded again, and then cut into new ultrathin sections. The different kinds of sections we have described here may also be studied using scanning electron microscopy. This systematic method facilitates correlative microscopy from lower to higher magnifications along with the usage of a broad variety of histological techniques including electron microscopy.
Collapse
Affiliation(s)
- Jorge Gayoso
- Department of Cell Biology, Histology and Pharmacology, School of Medicine and INCyL, University of Valladolid, Spain
| | - Manuel Garrosa
- Department of Cell Biology, Histology and Pharmacology, School of Medicine and INCyL, University of Valladolid, Spain
| | - Sara Gayoso
- Department of Cell Biology, Histology and Pharmacology, School of Medicine and INCyL, University of Valladolid, Spain
| | | | | | - Manuel José Gayoso
- Department of Cell Biology, Histology and Pharmacology, School of Medicine and INCyL, University of Valladolid, Spain.
| |
Collapse
|
9
|
Jamshidi M, Rajabian M, Avery MB, Sundararaj U, Ronsky J, Belanger B, Wong JH, Mitha AP. A novel self-expanding primarily bioabsorbable braided flow-diverting stent for aneurysms: initial safety results. J Neurointerv Surg 2019; 12:700-705. [PMID: 31776171 DOI: 10.1136/neurintsurg-2019-015555] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Revised: 11/14/2019] [Accepted: 11/14/2019] [Indexed: 11/03/2022]
Abstract
INTRODUCTION The advent of metal flow-diverting stents has provided neurointerventionalists with an option for treating aneurysms without requiring manipulations within the aneurysm sac. The large amount of metal in these stents, however, can lead to early and late thrombotic complications, and thus requires long-term antiplatelet agents. Bioabsorbable stents have been postulated to mitigate the risk of these complications. Here we present early data on the first self-expandable primarily bioabsorbable stent for aneurysms. METHODS Braided stents were developed using poly-L-lactic acid fibers with material surface area similar to metal flow diverters. Crush resistance force, hemolysis, and thrombogenicity were determined and compared with existing commercial devices. Stents were deployed in infra-renal rabbit aortas to determine angiographic side branch patency and to study neointima formation for a 1-month follow-up period. RESULTS Crush resistance force was determined to be on the order of existing commercial devices. Hemolytic behavior was similar to existing metal devices, and thrombogenicity was lower than metal flow-diverting stents. A smooth neointimal layer was found over the absorbable stent surface and all covered side branches were patent at follow-up. CONCLUSION The design of self-expanding primarily bioabsorbable flow-diverting stents is possible, and preliminary safety data is consistent with a favorable profile in terms of mechanical behavior, hemocompatibility, side branch patency, and histological effects. Additional in vitro and long-term in vivo studies are in progress and will help determine aneurysm occlusion rates and absorption characteristics of the stent.
Collapse
Affiliation(s)
- Mehdi Jamshidi
- Biomedical Engineering, University of Calgary Schulich School of Engineering, Calgary, Alberta, Canada
| | - Mahmoud Rajabian
- MIF Microscopy and Imaging Facility Faculty of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Michael B Avery
- Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada
| | | | - Janet Ronsky
- Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Alberta, Canada
| | - Brooke Belanger
- Clinical Neurosciences, University of Calgary Cumming School of Medicine, Calgary, Alberta, Canada
| | - John H Wong
- Clinical Neurosciences, University of Calgary Cumming School of Medicine, Calgary, Alberta, Canada
| | - Alim P Mitha
- Biomedical Engineering, University of Calgary Schulich School of Engineering, Calgary, Alberta, Canada .,Clinical Neurosciences, University of Calgary Cumming School of Medicine, Calgary, Alberta, Canada
| |
Collapse
|
10
|
Miller DV, Jensen TA, Bair TL, Jensen T. A novel, rapid, and low cost method for preparing tissues with metallic stents for routine histology. Cardiovasc Pathol 2019; 45:107177. [PMID: 31891881 DOI: 10.1016/j.carpath.2019.107177] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Accepted: 10/31/2019] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Coronary artery stenting has become a common procedure and cardiovascular pathology specimens containing these metallic stents are accordingly becoming common. Histologic examination of stented vessels is imperative, but special techniques are needed due to the presence of metal within the tissue. We describe a rapid and inexpensive method for preparing stented vascular specimens for routine histology suitable for use in almost any histology laboratory. DESIGN After formalin fixation and decalcification, stented vascular segments were freeze-embedded and sectioned using a handheld power micro cutoff wheel tool into ~1 mm slices. Sections were allowed to thaw and the strut shards removed with fine forceps. No longer containing metal, the sections were processed for routine paraffin embedding, microtomy and staining. RESULTS Histologic sections showed only minor tissue disruption around the stent struts. In our experience with 25 stented arteries (mean interval from implantation 5.6 years), the mean subjective section quality score was 4.1 out of 5. The position of each strut could easily be determined, along with neointimal in-stent restenosis and thrombosis. Local reaction to each strut could be surmised even if minor tissue disruption occurred. The entire process was completed in 2-3 days. The incremental cost over that of routine histology is nominal. CONCLUSION This method for examining stented vascular segments histologically could readily be applied in most pathology laboratories and serves as a highly practical solution to dilemma of examining stents histologically.
Collapse
Affiliation(s)
- Dylan V Miller
- Department of Pathology, Intermountain Medical Center, Salt Lake City, UT, USA.
| | | | - Tami L Bair
- Department of Cardiology, Intermountain Medical Center, Salt Lake City, UT, USA
| | - Thom Jensen
- Intermountain Biorepository, Salt Lake City, UT, USA
| |
Collapse
|
11
|
Delattre C, Velazquez D, Roques C, Pavon-Djavid G, Ollivier V, Lokajczyk A, Avramoglou T, Gueguen V, Louedec L, Caligiuri G, Jandrot-Perrus M, Boisson-Vidal C, Letourneur D, Meddahi-Pelle A. In vitro and in vivo evaluation of a dextran-graft-polybutylmethacrylate copolymer coated on CoCr metallic stent. ACTA ACUST UNITED AC 2019; 9:25-36. [PMID: 30788257 PMCID: PMC6378099 DOI: 10.15171/bi.2019.04] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 09/17/2018] [Accepted: 09/24/2018] [Indexed: 02/06/2023]
Abstract
Introduction: The major complications of stent implantation are restenosis and late stent thrombosis. PBMA polymers are used for stent coating because of their mechanical properties. We previously synthesized and characterized Dextrangraft-polybutylmethacrylate copolymer (Dex-PBMA) as a potential stent coating. In this study, we evaluated the haemocompatibility and biocompatibility properties of Dex-PBMA in vitro and in vivo. Methods: Here, we investigated: (1) the effectiveness of polymer coating under physiological conditions and its ability to release Tacrolimus®, (2) the capacity of Dex-PBMA to inhibit Staphylococcus aureus adhesion, (3) the thrombin generation and the human platelet adhesion in static and dynamic conditions, (4) the biocompatibility properties in vitro on human endothelial colony forming cells ( ECFC) and on mesenchymal stem cells (MSC) and in vivo in rat models, and (5) we implanted Dex-PBMA and Dex-PBMATAC coated stents in neointimal hyperplasia restenosis rabbit model. Results: Dex-PBMA coating efficiently prevented bacterial adhesion and release Tacrolimus®. Dex-PBMA exhibit haemocompatibility properties under flow and ECFC and MSC compatibility. In vivo, no pathological foreign body reaction was observed neither after intramuscular nor intravascular aortic implantation. After Dex-PBMA and Dex-PBMATAC coated stents 30 days implantation in a restenosis rabbit model, an endothelial cell coverage was observed and the lumen patency was preserved. Conclusion: Based on our findings, Dex-PBMA exhibited vascular compatibility and can potentially be used as a coating for metallic coronary stents.
Collapse
Affiliation(s)
- Cécilia Delattre
- INSERM, UMR_S1148, Laboratory for Vascular Translational Sciences, Hôpital Bichat
| | - Diego Velazquez
- INSERM, UMR_S1148, Laboratory for Vascular Translational Sciences, Hôpital Bichat
| | - Caroline Roques
- INSERM, UMR_S1148, Laboratory for Vascular Translational Sciences, Hôpital Bichat.,Université Paris 13, Sorbonne Paris Cité, France
| | - Graciela Pavon-Djavid
- INSERM, UMR_S1148, Laboratory for Vascular Translational Sciences, Hôpital Bichat.,Université Paris 13, Sorbonne Paris Cité, France
| | - Véronique Ollivier
- INSERM, UMR_S1148, Laboratory for Vascular Translational Sciences, Hôpital Bichat.,Université Paris 13, Sorbonne Paris Cité, France
| | - Anna Lokajczyk
- Inserm UMR_S1140, Paris France.,Université Paris Descartes, Sorbonne Paris Cité, France
| | - Thierry Avramoglou
- INSERM, UMR_S1148, Laboratory for Vascular Translational Sciences, Hôpital Bichat.,Université Paris 13, Sorbonne Paris Cité, France
| | - Virginie Gueguen
- INSERM, UMR_S1148, Laboratory for Vascular Translational Sciences, Hôpital Bichat.,Université Paris 13, Sorbonne Paris Cité, France
| | - Liliane Louedec
- INSERM, UMR_S1148, Laboratory for Vascular Translational Sciences, Hôpital Bichat.,Université Paris 13, Sorbonne Paris Cité, France
| | - Giuseppina Caligiuri
- INSERM, UMR_S1148, Laboratory for Vascular Translational Sciences, Hôpital Bichat.,Université Paris 13, Sorbonne Paris Cité, France
| | - Martine Jandrot-Perrus
- INSERM, UMR_S1148, Laboratory for Vascular Translational Sciences, Hôpital Bichat.,Université Paris 13, Sorbonne Paris Cité, France
| | | | - Didier Letourneur
- INSERM, UMR_S1148, Laboratory for Vascular Translational Sciences, Hôpital Bichat.,Université Paris 13, Sorbonne Paris Cité, France
| | - Anne Meddahi-Pelle
- INSERM, UMR_S1148, Laboratory for Vascular Translational Sciences, Hôpital Bichat.,Université Paris 13, Sorbonne Paris Cité, France
| |
Collapse
|
12
|
Zhao L, Sundaram S, Le AV, Huang AH, Zhang J, Hatachi G, Beloiartsev A, Caty MG, Yi T, Leiby K, Gard A, Kural MH, Gui L, Rocco KA, Sivarapatna A, Calle E, Greaney A, Urbani L, Maghsoudlou P, Burns A, DeCoppi P, Niklason LE. Engineered Tissue-Stent Biocomposites as Tracheal Replacements. Tissue Eng Part A 2017; 22:1086-97. [PMID: 27520928 DOI: 10.1089/ten.tea.2016.0132] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Here we report the creation of a novel tracheal construct in the form of an engineered, acellular tissue-stent biocomposite trachea (TSBT). Allogeneic or xenogeneic smooth muscle cells are cultured on polyglycolic acid polymer-metal stent scaffold leading to the formation of a tissue comprising cells, their deposited collagenous matrix, and the stent material. Thorough decellularization then produces a final acellular tubular construct. Engineered TSBTs were tested as end-to-end tracheal replacements in 11 rats and 3 nonhuman primates. Over a period of 8 weeks, no instances of airway perforation, infection, stent migration, or erosion were observed. Histological analyses reveal that the patent implants remodel adaptively with native host cells, including formation of connective tissue in the tracheal wall and formation of a confluent, columnar epithelium in the graft lumen, although some instances of airway stenosis were observed. Overall, TSBTs resisted collapse and compression that often limit the function of other decellularized tracheal replacements, and additionally do not require any cells from the intended recipient. Such engineered TSBTs represent a model for future efforts in tracheal regeneration.
Collapse
Affiliation(s)
- Liping Zhao
- 2 Department of Anesthesiology, Yale University , New Haven, Connecticut
| | - Sumati Sundaram
- 1 Department of Biomedical Engineering, Yale University , New Haven, Connecticut.,2 Department of Anesthesiology, Yale University , New Haven, Connecticut
| | - Andrew V Le
- 2 Department of Anesthesiology, Yale University , New Haven, Connecticut
| | - Angela H Huang
- 1 Department of Biomedical Engineering, Yale University , New Haven, Connecticut
| | - Jiasheng Zhang
- 3 Department of Internal Medicine Cardiology, Yale University , New Haven, Connecticut
| | - Go Hatachi
- 2 Department of Anesthesiology, Yale University , New Haven, Connecticut
| | - Arkadi Beloiartsev
- 2 Department of Anesthesiology, Yale University , New Haven, Connecticut
| | - Michael G Caty
- 4 Section of Pediatric Surgery, Yale University , New Haven, Connecticut
| | - Tai Yi
- 5 Nationwide Children's Hospital Research Institute , Columbus, Ohio
| | - Katherine Leiby
- 1 Department of Biomedical Engineering, Yale University , New Haven, Connecticut
| | - Ashley Gard
- 1 Department of Biomedical Engineering, Yale University , New Haven, Connecticut
| | - Mehmet H Kural
- 2 Department of Anesthesiology, Yale University , New Haven, Connecticut
| | - Liqiong Gui
- 2 Department of Anesthesiology, Yale University , New Haven, Connecticut
| | - Kevin A Rocco
- 2 Department of Anesthesiology, Yale University , New Haven, Connecticut
| | - Amogh Sivarapatna
- 1 Department of Biomedical Engineering, Yale University , New Haven, Connecticut
| | - Elizabeth Calle
- 1 Department of Biomedical Engineering, Yale University , New Haven, Connecticut
| | - Allison Greaney
- 1 Department of Biomedical Engineering, Yale University , New Haven, Connecticut
| | - Luca Urbani
- 6 UCL Institute of Child Health and Great Ormond Street Hospital , UCL, London, United Kingdom
| | - Panagiotis Maghsoudlou
- 6 UCL Institute of Child Health and Great Ormond Street Hospital , UCL, London, United Kingdom
| | - Alan Burns
- 6 UCL Institute of Child Health and Great Ormond Street Hospital , UCL, London, United Kingdom .,7 Department of Clinical Genetics, Erasmus Medical Center , Rotterdam, The Netherlands
| | - Paolo DeCoppi
- 6 UCL Institute of Child Health and Great Ormond Street Hospital , UCL, London, United Kingdom
| | - Laura E Niklason
- 1 Department of Biomedical Engineering, Yale University , New Haven, Connecticut.,2 Department of Anesthesiology, Yale University , New Haven, Connecticut
| |
Collapse
|
13
|
Basso C, Aguilera B, Banner J, Cohle S, d'Amati G, de Gouveia RH, di Gioia C, Fabre A, Gallagher PJ, Leone O, Lucena J, Mitrofanova L, Molina P, Parsons S, Rizzo S, Sheppard MN, Mier MPS, Kim Suvarna S, Thiene G, van der Wal A, Vink A, Michaud K. Guidelines for autopsy investigation of sudden cardiac death: 2017 update from the Association for European Cardiovascular Pathology. Virchows Arch 2017; 471:691-705. [PMID: 28889247 PMCID: PMC5711979 DOI: 10.1007/s00428-017-2221-0] [Citation(s) in RCA: 310] [Impact Index Per Article: 44.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2017] [Revised: 08/10/2017] [Accepted: 08/13/2017] [Indexed: 02/07/2023]
Abstract
Although sudden cardiac death (SCD) is one of the most important modes of death in Western countries, pathologists and public health physicians have not given this problem the attention it deserves. New methods of preventing potentially fatal arrhythmias have been developed and the accurate diagnosis of the causes of SCD is now of particular importance. Pathologists are responsible for determining the precise cause and mechanism of sudden death but there is still considerable variation in the way in which they approach this increasingly complex task. The Association for European Cardiovascular Pathology has developed these guidelines, which represent the minimum standard that is required in the routine autopsy practice for the adequate investigation of SCD. The present version is an update of our original article, published 10 years ago. This is necessary because of our increased understanding of the genetics of cardiovascular diseases, the availability of new diagnostic methods, and the experience we have gained from the routine use of the original guidelines. The updated guidelines include a detailed protocol for the examination of the heart and recommendations for the selection of histological blocks and appropriate material for toxicology, microbiology, biochemistry, and molecular investigation. Our recommendations apply to university medical centers, regionals hospitals, and all healthcare professionals practicing pathology and forensic medicine. We believe that their adoption throughout Europe will improve the standards of autopsy practice, allow meaningful comparisons between different communities and regions, and permit the identification of emerging patterns of diseases causing SCD. Finally, we recommend the development of regional multidisciplinary networks of cardiologists, geneticists, and pathologists. Their role will be to facilitate the identification of index cases with a genetic basis, to screen appropriate family members, and ensure that appropriate preventive strategies are implemented.
Collapse
Affiliation(s)
- Cristina Basso
- Cardiovascular Pathology, Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy.
| | - Beatriz Aguilera
- Histopathology Service, National Institute of Toxicology and Forensic Sciences, Madrid, Spain
| | - Jytte Banner
- Department of Forensic Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Stephan Cohle
- Department of Pathology and Laboratory Medicine, Grand Rapids, MI, USA
| | - Giulia d'Amati
- Department of Radiological, Oncological and Pathological Sciences, Sapienza, University of Rome, Rome, Italy
| | - Rosa Henriques de Gouveia
- Department of Pathology, Hospital de Santa Cruz (CHLO), Lisbon & Forensic Pathology, INMLCF & FMUC, Coimbra, Portugal
| | - Cira di Gioia
- Department of Radiological, Oncological and Pathological Sciences, Sapienza, University of Rome, Rome, Italy
| | - Aurelie Fabre
- Department of Histopathology, St Vincent's University Hospital, University College Dublin School of Medicine, Dublin, Ireland
| | | | - Ornella Leone
- Department of Pathology, Sant'Orsola-Malpighi University Hospital, Bologna, Italy
| | - Joaquin Lucena
- Forensic Pathology Service, Institute of Legal Medicine and Forensic Sciences, Seville, Spain
| | - Lubov Mitrofanova
- Department of Pathology, Federal Almazov North-West Medical Research Centre, St. Petersburg, Russian Federation
| | - Pilar Molina
- Forensic Pathology Service, Institute of Legal Medicine and Forensic Sciences, Valencia, Spain
| | - Sarah Parsons
- Victorian Institute of Forensic Medicine and Monash University, Victoria, Australia
| | - Stefania Rizzo
- Cardiovascular Pathology, Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy
| | - Mary N Sheppard
- Department of Cardiovascular Pathology, St Georges Medical School, London, UK
| | - Maria Paz Suárez Mier
- Histopathology Service, National Institute of Toxicology and Forensic Sciences, Madrid, Spain
| | | | - Gaetano Thiene
- Cardiovascular Pathology, Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Padua, Italy
| | - Allard van der Wal
- Pathology, Academic Medical Center, University of Amsterdam, Amsterdam, Netherlands
| | - Aryan Vink
- Department of Pathology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Katarzyna Michaud
- University Hospital of Lausanne, University Center of Legal Medicine, Lausanne and Geneva, Chemin de la Vulliette 4, 25, 1000, Lausanne, Switzerland.
| | | |
Collapse
|
14
|
Reese SP, Farhang N, Poulson R, Parkman G, Weiss JA. Nanoscale Imaging of Collagen Gels with Focused Ion Beam Milling and Scanning Electron Microscopy. Biophys J 2017; 111:1797-1804. [PMID: 27760365 DOI: 10.1016/j.bpj.2016.08.039] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2015] [Revised: 07/29/2016] [Accepted: 08/26/2016] [Indexed: 12/13/2022] Open
Abstract
In vitro polymerized type I collagen hydrogels have been used extensively as a model system for three-dimensional (3D) cell and tissue culture, studies of fibrillogenesis, and investigation of multiscale force transmission within connective tissues. The nanoscale organization of collagen fibrils plays an essential role in the mechanics of these gels and emergent cellular behavior in culture, yet quantifying 3D structure with nanoscale resolution to fully characterize fibril organization remains a significant technical challenge. In this study, we demonstrate that a new imaging modality, focused ion beam scanning electron microscopy (FIB-SEM), can be used to generate 3D image datasets for visualizing and quantifying complex nanoscale organization and morphometry in collagen gels. We polymerized gels at a number of concentrations and conditions commonly used for in vitro models, stained and embedded the samples, and performed FIB-SEM imaging. The resulting image data had a voxel size of 25 nm, which is the highest resolution 3D data of a collagen fibril network ever obtained for collagen gels. This resolution was essential for discerning individual fibrils, fibril paths, and their branching and grouping. The resulting volumetric images revealed that polymerization conditions have a significant impact on the complex fibril morphology of the gels. We segmented the fibril network and demonstrated that individual collagen fibrils can be tracked in 3D space, providing quantitative analysis of network descriptors such as fibril diameter distribution, length, branch points, and fibril aggregations. FIB-SEM 3D reconstructions showed considerably less lateral grouping and overlap of fibrils than standard 2D SEM images, likely due to artifacts in SEM introduced by dehydration. This study demonstrates the utility of FIB-SEM for 3D imaging of collagen gels and quantitative analysis of 3D fibril networks. We anticipate that the method will see application in future studies of structure-function relationships in collagen gels as well as native collagenous tissues.
Collapse
Affiliation(s)
- Shawn P Reese
- Bioengineering, University of Utah, Salt Lake City, Utah
| | | | - Randy Poulson
- Bioengineering, University of Utah, Salt Lake City, Utah
| | - Gennie Parkman
- Bioengineering, University of Utah, Salt Lake City, Utah
| | | |
Collapse
|
15
|
Long-term in vivo corrosion behavior, biocompatibility and bioresorption mechanism of a bioresorbable nitrided iron scaffold. Acta Biomater 2017; 54:454-468. [PMID: 28315492 DOI: 10.1016/j.actbio.2017.03.020] [Citation(s) in RCA: 89] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2016] [Revised: 02/11/2017] [Accepted: 03/13/2017] [Indexed: 01/05/2023]
Abstract
Pure iron as a potential bioresorbable material for bioresorbable coronary scaffold has major disadvantages of slow corrosion and bioresorption. However, so far, there are neither quantitative data of long-term in vivo corrosion nor direct experimental evidence for bioresorption of pure iron and its alloys, which are fundamental and vital for developing novel Fe-based alloys overcoming the intrinsic drawbacks of pure iron. This work systemically investigated scaffold performance, long-term in vivo corrosion behavior and biocompatibility of a nitrided iron coronary scaffold and explored its bioresorption mechanism. It was found that the 70μm Fe-based scaffold was superior to a state of the art Co-Cr alloy stent (Xience Prime™) in terms of crossing profile, recoil and radial strength. Mass loss was 76.0±8.5wt% for the nitrided iron scaffold and 44.2±11.4wt% for the pure iron scaffold after 36months implantation in rabbit abdominal aorta (p<0.05). The Fe-based scaffold showed good long-term biocompatibility in both rabbit and porcine model. Its insoluble corrosion products were demonstrated biosafe and could be cleared away by macrophages from in situ to adventitia to be indiscernible by Micro Computed Tomography and probably finally enter the lymphatics and travel to lymph nodes after 53months implantion in porcine coronary artery. The results indicate that the nitrided iron scaffold with further improvements shall be promising for coronary application. STATEMENT OF SIGNIFICANCE Pure iron as a potential bioresorbable material has major disadvantages of slow corrosion and bioresorption. However, so far, there are neither quantitative data of long-term in vivo corrosion nor direct experimental evidence for bioresorption of pure iron and its alloys. Only this work systemically investigated long-term in vivo corrosion behavior and biocompatibility of a nitrided iron coronary scaffold up to 53months after implantation and explored its bioresorption mechanism. These are fundamental and vital for developing novel Fe-based alloys overcoming the intrinsic drawbacks of pure iron. Novel testing and section-preparing methods were also provided in this work to facilitate future research and development of novel Fe-based alloy scaffolds.
Collapse
|
16
|
[Histopatological study of stented coronary artery treated with the electrodeposition technique]. ARCHIVOS DE CARDIOLOGIA DE MEXICO 2016; 87:81-82. [PMID: 27979504 DOI: 10.1016/j.acmx.2016.09.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2016] [Revised: 09/07/2016] [Accepted: 09/12/2016] [Indexed: 11/20/2022] Open
|
17
|
Fishbein I, Welch T, Guerrero DT, Alferiev IS, Adamo RF, Chorny M, Gupte RK, Tang Y, Levy RJ. Paraffin processing of stented arteries using a postfixation dissolution of metallic and polymeric stents. Cardiovasc Pathol 2016; 25:483-488. [PMID: 27616613 DOI: 10.1016/j.carpath.2016.08.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Revised: 08/15/2016] [Accepted: 08/16/2016] [Indexed: 12/20/2022] Open
Abstract
Studying the morphology of the arterial response to endovascular stent implantation requires embedding the explanted stented artery in rigid materials such as poly(methyl methacrylate) to enable sectioning through both the in situ stent and the arterial wall, thus maintaining the proper anatomic relationships. This is a laborious, time-consuming process. Moreover, the technical quality of stained plastic sections is typically suboptimal and, in some cases, precludes immunohistochemical analysis. Here we describe a novel technique for dissolution of metallic and plastic stents that is compatible with subsequent embedding of "destented" arteries in paraffin, fine sectioning, major staining protocols, and immunohistochemistry.
Collapse
Affiliation(s)
- Ilia Fishbein
- The Children's Hospital of Philadelphia, Philadelphia, PA, USA; Department of Pediatrics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
| | - Tre Welch
- Department of Cardio-Thoracic Surgery, University of Texas, Dallas, Richardson, TX, USA
| | | | - Ivan S Alferiev
- The Children's Hospital of Philadelphia, Philadelphia, PA, USA; Department of Pediatrics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Richard F Adamo
- The Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Michael Chorny
- The Children's Hospital of Philadelphia, Philadelphia, PA, USA; Department of Pediatrics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Rohit K Gupte
- The Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Yanqing Tang
- The Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Robert J Levy
- The Children's Hospital of Philadelphia, Philadelphia, PA, USA; Department of Pediatrics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
18
|
Opie NL, van der Nagel NR, John SE, Vessey K, Rind GS, Ronayne SM, Fletcher EL, May CN, OBrien TJ, Oxley TJ. Micro-CT and Histological Evaluation of an Neural Interface Implanted Within a Blood Vessel. IEEE Trans Biomed Eng 2016; 64:928-934. [PMID: 27337706 DOI: 10.1109/tbme.2016.2552226] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Recently, we reported the development of a stent-mounted electrode array (Stentrode) capable of chronically recording neural signals from within a blood vessel with high fidelity. Preliminary data suggested incorporation of the Stentrode into the blood vessel wall was associated with improved recording sensitivity. We now investigate neointimal incorporation of the Stentrode, implanted in a cohort of sheep for up to 190 days. METHODS Micro-CT, obtained from the Imaging and Medical Beamline at the Australian Synchrotron, and histomorphometic techniques developed specifically for evaluation of cerebral vasculature implanted with a stent-electrode array were compared as measures to assess device incorporation and vessel patency. RESULTS Both micro-CT analysis and histomorphometry, revealed a strong correlation between implant duration and the number of incorporated stent struts. <10% (26/268) of stent struts were covered in neointima in sheep implanted for <2 weeks, increasing to >78% (191/243) between 2 and 4 weeks. Average strut-to-lumen thickness from animals implanted >12 weeks was comparable across both modalities, 339 ±15 μm measured using micro-CT and 331 ±19 μm ( n = 292) measured histologically. There was a strong correlation between lumen areas measured using the two modalities ( ), with no observation of vessel occlusion observed from any of the 12 animals implanted for up to 190 days. CONCLUSION Micro-CT and the histomorphometric techniques we developed are comparable and can both be used to identify incorporation of a Stentrode implanted in cerebral vessels. SIGNIFICANCE This study demonstrates preliminary safety of a stent-electrode array implanted in cerebral vasculature, which may facilitate technological advances in minimally invasive brain-computer interfaces.
Collapse
|
19
|
Grinding and polishing instead of sectioning for the tissue samples with a graft: Implications for light and electron microscopy. Micron 2016; 85:1-7. [DOI: 10.1016/j.micron.2016.03.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2015] [Revised: 03/18/2016] [Accepted: 03/18/2016] [Indexed: 11/22/2022]
|
20
|
Maleszewski J, Lai C, Veinot J. Anatomic Considerations and Examination of Cardiovascular Specimens (Excluding Devices). Cardiovasc Pathol 2016. [DOI: 10.1016/b978-0-12-420219-1.00001-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
21
|
LVAD Inflow Cannula Covered with a Titanium Mesh Induces Neointimal Tissue with Neovessels. Int J Artif Organs 2015; 38:316-24. [DOI: 10.5301/ijao.5000423] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/06/2015] [Indexed: 11/20/2022]
Abstract
Background Thrombus formation at the interfaces of inflow cannulas and left ventricular apexes is considered to be one of the predominant sources of thromboembolic complication. Use of a fine titanium mesh-covered inflow cannula is expected to prevent such thrombus formation by inducing neointimal tissue around the cannula. Methods Titanium pins (20 mm long, 3 mm diameter) covered with a fine titanium mesh (wire dia. 85 μm; volumetric porosity 40–70%) were developed to mimic the inflow cannulas of left ventricular assist devices (LVADs). Smooth-surface pins of the same size were also designed. The pins were implanted into the left ventricular apexes of rabbits. The rabbits were bled without anticoagulation for between 1 week and 1 year. The tissues around the pins were evaluated histologically. Results 28 rabbits (mesh group, 15; smooth group, 13) were evaluated. The mesh-covered pins inhibited thrombus formation to a remarkable degree throughout the entire observation period. The tissues around the mesh-covered titanium pins appeared to be in the process of conversion from thrombus formation to granulation, resulting in the replacement of fibrotic tissue containing myofibroblasts with endothelialized and angiogenic tissue. On the surface of the mesh-covered pins, endothelial cells were arranged without platelet adhesion. The tissue formed around the smooth-surface pins was partially organized into a thrombus without angiogenesis. Conclusions The titanium-mesh surface modification prevented thrombus formation with formation of neointimal tissue with endothelialization and angiogenesis. This surface modification could prevent wedge thrombus formation among patients supported by LVADs.
Collapse
|
22
|
Roberts A, Trainor KE, Weeks B, Jackson N, Troughton RW, Charles CJ, Rademaker MT, Melton IC, Crozier IG, Hafelfinger W, Gutfinger DE, Eigler NL, Abraham WT, Clubb FJ. Integrated microscopy techniques for comprehensive pathology evaluation of an implantable left atrial pressure sensor. J Histotechnol 2013; 36:17-24. [PMID: 25258469 PMCID: PMC4161197 DOI: 10.1179/2046023613y.0000000021] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Abstract
The safety and efficacy of an implantable left atrial pressure (LAP) monitoring system is being evaluated in a clinical trial setting. Because the number of available specimens from the clinical trial for histopathology analysis is limited, it is beneficial to maximize the usage of each available specimen by relying on integrated microscopy techniques. The aim of this study is to demonstrate how a comprehensive pathology analysis of a single specimen may be reliably achieved using integrated microscopy techniques. Integrated microscopy techniques consisting of high-resolution gross digital photography followed by micro-computed tomography (micro-CT) scanning, low-vacuum scanning electron microscopy (LVSEM), and microground histology with special stains were applied to the same specimen. Integrated microscopy techniques were applied to eight human specimens. Micro-CT evaluation was beneficial for pinpointing the location and position of the device within the tissue, and for identifying any areas of interest or structural flaws that required additional examination. Usage of LVSEM was reliable in analyzing surface topography and cell type without destroying the integrity of the specimen. Following LVSEM, the specimen remained suitable for embedding in plastic and sectioning for light microscopy, using the positional data gathered from the micro-CT to intersect areas of interest in the slide. Finally, hematoxylin and eosin (H&E) and methylene blue staining was deployed on the slides with high-resolution results. The integration of multiple techniques on a single specimen maximized the usage of the limited number of available specimens from the clinical trial setting. Additionally, this integrated microscopic evaluation approach was found to have the added benefit of providing greater assurance of the derived conclusions because it was possible to cross-validate the results from multiple tests on the same specimen.
Collapse
Affiliation(s)
- A Roberts
- Department of Veterinary Pathobiology, Texas A&M University, College Station, TX, USA
| | - K E Trainor
- Department of Veterinary Pathobiology, Texas A&M University, College Station, TX, USA
| | - B Weeks
- Department of Veterinary Pathobiology, Texas A&M University, College Station, TX, USA
| | - N Jackson
- Department of Veterinary Pathobiology, Texas A&M University, College Station, TX, USA
| | - R W Troughton
- Department of Cardiology, Christchurch Hospital and University of Otago, Christchurch, New Zealand
| | - C J Charles
- Department of Cardiology, Christchurch Hospital and University of Otago, Christchurch, New Zealand
| | - M T Rademaker
- Department of Cardiology, Christchurch Hospital and University of Otago, Christchurch, New Zealand
| | - I C Melton
- Department of Cardiology, Christchurch Hospital and University of Otago, Christchurch, New Zealand
| | - I G Crozier
- Department of Cardiology, Christchurch Hospital and University of Otago, Christchurch, New Zealand
| | - W Hafelfinger
- St. Jude Medical, Cardiac Rhythm Management Division, Sylmar, CA, USA
| | - D E Gutfinger
- St. Jude Medical, Cardiac Rhythm Management Division, Sylmar, CA, USA
| | - N L Eigler
- St. Jude Medical, Cardiac Rhythm Management Division, Sylmar, CA, USA
| | - W T Abraham
- Division of Cardiovascular Medicine, Ohio State University, Columbus, OH, USA
| | - F J Clubb
- Department of Veterinary Pathobiology, Texas A&M University, College Station, TX, USA
| |
Collapse
|
23
|
Xing Z, Pedersen TO, Wu X, Xue Y, Sun Y, Finne-Wistrand A, Kloss FR, Waag T, Krueger A, Steinmüller-Nethl D, Mustafa K. Biological effects of functionalizing copolymer scaffolds with nanodiamond particles. Tissue Eng Part A 2013; 19:1783-91. [PMID: 23574424 DOI: 10.1089/ten.tea.2012.0336] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Significant evidence has indicated that poly(L-lactide)-co-(ɛ-caprolactone) [(poly(LLA-co-CL)] scaffolds could be one of the suitable candidates for bone tissue engineering. Oxygen-terminated nanodiamond particles (n-DP) were combined with poly(LLA-co-CL) and revealed to be positive for cell growth. In this study, we evaluated the influence of poly(LLA-co-CL) scaffolds modified by n-DP on attachment, proliferation, differentiation of bone marrow stromal cells (BMSCs) in vitro, and on bone formation using a sheep calvarial defect model. BMSCs were seeded on either poly(LLA-co-CL)- or n-DP-coated scaffolds and incubated for 1 h. Scanning electron microscopy (SEM) and fluorescence microscopy were used in addition to protein and DNA measurements to evaluate cellular attachment on the scaffolds. To determine the effect of n-DP on proliferation of BMSCs, cell/scaffold constructs were harvested after 3 days and evaluated by Bicinchoninic Acid (BCA) protein assay and SEM. In addition, the osteogenic differentiation of cells grown for 2 weeks on the various scaffolds and in a dynamic culture condition was evaluated by real-time RT-PCR. Unmodified and modified scaffolds were implanted into the calvaria of six-year-old sheep. The expression of collagen type I (COL I) and bone morphogenetic protein-2 (BMP-2) after 4 weeks as well as the formation of new bone after 12 and 24 weeks were analyzed by immunohistochemistry and histology. Scaffolds modified with n-DP supported increased cell attachment and the mRNA expression of osteopontin (OPN), bone sialoprotein (BSP), and BMP-2 were significantly increased after 2 weeks of culture. The BMSCs had spread well on the various scaffolds investigated after 3 days in the study with no significant difference in cell proliferation. Furthermore, the in vivo data revealed more positive staining of COL I and BMP-2 in relation to the n-DP-coated scaffolds after 4 weeks and presented more bone formation after 12 and 24 weeks. n-DP modification significantly increased cell attachment and differentiation of BMSCs on poly(LLA-co-CL) scaffolds in vitro and enhanced bone formation in vivo.
Collapse
Affiliation(s)
- Zhe Xing
- Department of Clinical Dentistry, Center for Clinical Dental Research, University of Bergen, Bergen, Norway
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
First in vitro and in vivo results of an anti-human CD133-antibody coated coronary stent in the porcine model. Clin Res Cardiol 2013; 102:413-25. [PMID: 23397592 DOI: 10.1007/s00392-013-0547-4] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2012] [Accepted: 01/23/2013] [Indexed: 12/15/2022]
Abstract
BACKGROUND Drug-eluting stents successfully reduce restenosis at the cost of delayed re-endothelialization. A novel concept to enhance re-endothelialization is the use of antibody-coated stents which capture circulating progenitor cells. A CD34-positive-cell-capturing stent was recently developed with conflicting clinical results. CD133 is a glycoprotein expressed on circulating hematopoietic and putative endothelial-regenerating cells and may be superior to CD34. OBJECTIVE The aim of our study was to develop a CD133-cell-capturing bare-metal stent and investigate feasibility, safety, and efficacy of CD133-stents in terms of re-endothelialization and neointima inhibition. METHODS AND RESULTS Anti-human CD133-antibodies were covalently attached to bare-metal stents. In vitro, binding capacity of CD133-stents was studied, revealing a significantly higher affinity of human CD133-positive cells to CD133-stents compared with mononuclear cells (MNCs). In vivo, 15 landrace pigs received BMS and CD133-stents in either RCX or LAD (n = 30 stents). Re-endothelialization was examined on day 1 (n = 4), 3 (n = 4) and day 7 (n = 4) using scanning electron microscopy. In histology, injury and inflammatory scores, as well as diameter restenosis were evaluated after day 7 (n = 3), 14 (n = 4), and 28 (n = 2). Overall no reduction in re-endothelialization, diameter stenosis or inflammatory score was seen with CD133-stents. CONCLUSION Stent coating with anti-human CD133-antibodies was successfully achieved with effective binding of CD133-positive cells. However, in vivo, no difference in re-endothelialization or neointima formation was evident with the use of CD133-stents compared with BMS. The low number of circulating CD133-positive cells and an increase in unspecific binding of MNCs over time may account for the observed lack of efficacy.
Collapse
|
25
|
Cuerrier CM, Chen YX, Tremblay D, Rayner K, McNulty M, Zhao X, Kennedy CRJ, de BelleRoche J, Pelling AE, O'Brien ER. Chronic over-expression of heat shock protein 27 attenuates atherogenesis and enhances plaque remodeling: a combined histological and mechanical assessment of aortic lesions. PLoS One 2013; 8:e55867. [PMID: 23409070 PMCID: PMC3567023 DOI: 10.1371/journal.pone.0055867] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2012] [Accepted: 01/03/2013] [Indexed: 11/19/2022] Open
Abstract
Aims Expression of Heat Shock Protein-27 (HSP27) is reduced in human coronary atherosclerosis. Over-expression of HSP27 is protective against the early formation of lesions in atherosclerosis-prone apoE−/− mice (apoE−/−HSP27o/e) - however, only in females. We now seek to determine if chronic HSP27 over-expression is protective in a model of advanced atherosclerosis in both male and female apoE−/− mice. Methods and Results After 12 weeks on a high fat diet, serum HSP27 levels rose more than 16-fold in male and female apoE−/−HSP27o/e mice, although females had higher levels than males. Relative to apoE−/− mice, female apoE−/−HSP27o/e mice showed reductions in aortic lesion area of 35% for en face and 30% for cross-sectional sinus tissue sections – with the same parameters reduced by 21% and 24% in male cohorts; respectively. Aortic plaques from apoE−/−HSP27o/e mice showed almost 50% reductions in the area occupied by cholesterol clefts and free cholesterol, with fewer macrophages and reduced apoptosis but greater intimal smooth muscle cell and collagen content. The analysis of the aortic mechanical properties showed increased vessel stiffness in apoE−/−HSP27o/e mice (41% in female, 34% in male) compare to apoE−/− counterparts. Conclusions Chronic over-expression of HSP27 is atheroprotective in both sexes and coincides with reductions in lesion cholesterol accumulation as well as favorable plaque remodeling. These data provide new clues as to how HSP27 may improve not only the composition of atherosclerotic lesions but potentially their stability and resilience to plaque rupture.
Collapse
Affiliation(s)
- Charles M. Cuerrier
- University of Ottawa Heart Institute, Ottawa, Canada
- Centre for Interdisciplinary NanoPhysics, Department of Physics, University of Ottawa, Ottawa, Canada
| | | | - Dominique Tremblay
- Centre for Interdisciplinary NanoPhysics, Department of Physics, University of Ottawa, Ottawa, Canada
| | - Katey Rayner
- University of Ottawa Heart Institute, Ottawa, Canada
| | | | - XiaoLing Zhao
- University of Ottawa Heart Institute, Ottawa, Canada
| | | | | | - Andrew E. Pelling
- Centre for Interdisciplinary NanoPhysics, Department of Physics, University of Ottawa, Ottawa, Canada
- Department of Biology, University of Ottawa, Ottawa, Canada
- Institute for Science, Society and Policy, University of Ottawa, Ottawa, Canada
| | - Edward R. O'Brien
- University of Ottawa Heart Institute, Ottawa, Canada
- Libin Cardiovascular Institute of Alberta, Calgary, Canada
- * E-mail:
| |
Collapse
|
26
|
Moodley L, Franz T, Human P, Wolf MF, Bezuidenhout D, Scherman J, Zilla P. Protective constriction of coronary vein grafts with knitted nitinol. Eur J Cardiothorac Surg 2013; 44:64-71. [PMID: 23295444 DOI: 10.1093/ejcts/ezs670] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES Different flow patterns and shear forces were shown to cause significantly more luminal narrowing and neointimal tissue proliferation in coronary than in infrainguinal vein grafts. As constrictive external mesh support of vein grafts led to the complete suppression of intimal hyperplasia (IH) in infrainguinal grafts, we investigated whether mesh constriction is equally effective in the coronary position. METHODS Eighteen senescent Chacma baboons (28.8 ± 3.6 kg) received aorto-coronary bypass grafts to the left anterior descending artery (LAD). Three groups of saphenous vein grafts were compared: untreated controls (CO); fibrin sealant-sprayed controls (CO + FS) and nitinol mesh-constricted grafts (ME + FS). Meshes consisted of pulse-compliant, knitted nitinol (eight needles; 50 μm wire thickness; 3.4 mm resting inner diameter, ID) spray attached to the vein grafts with FS. After 180 days of implantation, luminal dimensions and IH were analysed using post-explant angiography and macroscopic and histological image analysis. RESULTS At implantation, the calibre mismatch between control grafts and the LAD expressed as cross-sectional quotient (Qc) was pronounced [Qc = 0.21 ± 0.07 (CO) and 0.18 ± 0.05 (CO + FS)]. Mesh constriction resulted in a 29 ± 7% reduction of the outer diameter of the vein grafts from 5.23 ± 0.51 to 3.68 ± 0 mm, significantly reducing the calibre discrepancy to a Qc of 0.41 ± 0.17 (P < 0.02). After 6 months of implantation, explant angiography showed distinct luminal irregularities in control grafts (ID difference between widest and narrowest segment 74 ± 45%), while diameter variations were mild in mesh-constricted grafts. In all control grafts, thick neointimal tissue was present [600 ± 63 μm (CO); 627 ± 204 μm (CO + FS)] as opposed to thin, eccentric layers of 249 ± 83 μm in mesh-constricted grafts (ME + FS; P < 0.002). The total wall thickness had increased by 363 ± 39% (P < 0.00001) in CO and 312 ± 61% (P < 0.00001) in CO + FS vs 82 ± 61% in ME + FS (P < 0.007). CONCLUSIONS In a senescent non-human primate model for coronary artery bypass grafts, constrictive, external mesh support of saphenous veins with knitted nitinol prevented focal, irregular graft narrowing and suppressed neointimal tissue proliferation by a factor of 2.5. The lower degree of suppression of IH compared with previous infrainguinal grafts coincided with a lesser reduction of calibre mismatch in the coronary grafts.
Collapse
Affiliation(s)
- Loven Moodley
- Chris Barnard Department of Cardiothoracic Surgery, University of Cape Town, Cape Town, South Africa
| | | | | | | | | | | | | |
Collapse
|
27
|
Abstract
Cardiovascular devices such as coronary artery stents, ventricular assist devices, pacemakers, automated implantable cardioverter-defibrillators and septal closure devices are life saving and improve quality of life for millions of patients each year. Complications of these devices include thrombosis/thromboembolism, infection, structural failure and adverse material-tissue interactions. These findings should be sought when these devices are encountered on the surgical pathology bench or at autopsy.
Collapse
Affiliation(s)
- Robert F Padera
- Department of Pathology, Brigham and Women's Hospital, 75 Francis Street, Boston, MA 02115, USA
| |
Collapse
|
28
|
Houbballah R, Robaldo A, Albadawi H, Titus J, LaMuraglia GM. A novel model of accelerated intimal hyperplasia in the pig iliac artery. Int J Exp Pathol 2011; 92:422-7. [PMID: 22050434 DOI: 10.1111/j.1365-2613.2011.00790.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
There is no good animal model of large artery injury-induced intimal hyperplasia (IH). Those available are reproducible, providing only a few layers of proliferating cells or have the disadvantage of the presence of a metallic stent that complicates histology evaluation. This study was designed to develop a new, simple model of accelerated IH based on balloon injury in conjunction with disruption of the Internal Elastic Lamina (IEL) in pig external iliac arteries. Iliac artery injury (n = 24) was performed in 12 Yorkshire pigs divided in two groups: Group I (n = 10), overdistention injury induced by an oversized non-compliant balloon; Group II (n = 14), arterial wall disruption by pulling back an isometric cutting balloon (CB) followed by stretching with a compliant Fogarty Balloon (FB). At two weeks, arteries were processed for morphometric analysis and immunohistochemistry (IHC) for smooth muscle cells (SMC) and proliferating cell nuclear antigen (PCNA). When comparing the two groups, at 2 weeks, arteries of group II had a higher incidence of IH (100%vs. 50%, P = 0.0059), increased intimal areas (2.54 ± 0.33 mm(2) vs. 0.93 ± 0.36 mm(2) , P = 0.004), increased intimal area/Media area ratios (0.95 ± 0.1 vs. 0.28 ± 0.05; P < 0.0001) and decreased lumen areas (6.24 ± 0.44 vs. 9.48 ± 1.56, P = 0.026). No thrombosis was noticed in Group II. Neointima was composed by proliferating SMC located with the highest concentration in the area of IEL disruption (IHC). Arterial injury by pulling back CB and FB induces significant IH in pig iliac arteries by two weeks without thrombosis. This model is superior to the classical overdistention non-compliant model and should be useful and cost-effective for preclinical testing of procedures designed to inhibit IH in large peripheral arteries.
Collapse
Affiliation(s)
- Rabih Houbballah
- Division of Vascular and Endovascular Surgery of the General Surgical Services, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
| | | | | | | | | |
Collapse
|
29
|
Singhrao SK, Nicholson K, Crean S. Informed choices for challenging specimens when choosing methacrylate resin systems for histology. Microsc Res Tech 2011; 75:576-85. [DOI: 10.1002/jemt.21094] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2011] [Accepted: 08/23/2011] [Indexed: 11/10/2022]
|
30
|
Padera RF, Mitchell RN. The Intervened Heart: Cardiac Hardware in the Forensic Suite. Acad Forensic Pathol 2011. [DOI: 10.23907/2011.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Cardiovascular interventions—in the form of bypass grafts, stents, prosthetic valves, and ventricular assist devices—are increasingly common for the typical citizen of the industrialized world. While these certainly contribute to longevity and improved quality of life, they can also be a source of morbidity and mortality. In most cases, a handful of predictable pathogenic pathways underlie the eventual degeneration or failure of the various interventions, and may be implicated as a cause of death. Much less frequently, an untoward and unexpected complication can be the culprit. The objectives of this manuscript are to describe the more common cardiac interventions (both mechanical and surgical), highlight the typical failure modes, and present approaches to evaluate devices and grafts when encountered in the forensic autopsy suite.
Collapse
Affiliation(s)
- Robert F. Padera
- Pathologist at Brigham and Women's Hospital and Pathology at Harvard Medical School in Boston, Massachusetts
| | - Richard N. Mitchell
- Department of Pathology Boston, Massachusetts, and Harvard Medical School -Department of Pathology Boston, Massachusetts (RM)
| |
Collapse
|
31
|
Grudtner MA, de Lara Elesbão JL, Gutierrez PS, Meyer FS, Pereira AH. Histological analysis of cobalt-chromium stents with and without Camouflage® polymer coating: experimental porcine carotid artery model. Vascular 2011; 19:89-96. [PMID: 21489934 DOI: 10.1258/vasc.2010.oa0268] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
This study evaluated the arterial response to cobalt-chromium stents with and without polymer coating (Camouflage®, Hemoteq AG, Wuerselen, Germany) implanted in pigs. Cobalt-chromium balloon-expandable stents (4 × 16 mm) were implanted in the common carotid arteries of nine pigs. Histological analysis of endothelialization, inflammation and injury was performed one month later. All stents were successfully deployed, and all but one animal survived the 30 study days. All arteries were patent. Endothelialization was nearly complete in most sections of all carotid stents in both groups. There were mild inflammatory infiltrate and mild-to-moderate injury, which were associated with the stent shafts and not significantly different between groups. Our findings suggest that, in porcine carotid arteries, the histological response to balloon-expandable cobalt-chromium stents coated with polymer (Camouflage®, Hemoteq AG) is similar to the response to non-coated cobalt-chromium stents.
Collapse
|
32
|
Improved protocol for processing stented porcine coronary arteries for immunostaining. J Mol Histol 2011; 42:187-93. [DOI: 10.1007/s10735-011-9316-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2010] [Accepted: 01/20/2011] [Indexed: 11/26/2022]
|
33
|
Cardinal KO, Williams SK. Assessment of the intimal response to a protein-modified stent in a tissue-engineered blood vessel mimic. Tissue Eng Part A 2010; 15:3869-76. [PMID: 19563259 DOI: 10.1089/ten.tea.2009.0193] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Protein-coated intravascular stents have emerged as potential pro-healing modifications for or alternatives to anti-proliferative drug-eluting stents. To support the development of these devices, preclinical testing is required to evaluate the intimal response to new coatings and modifications. The purpose of this work was to implement a tissue-engineered blood vessel as an in vitro testing system to evaluate extracellular matrix-modified stents with regard to endothelialization of the stent surface. Stents were modified by submersion in a protein-enriched medium and were subsequently deployed within tissue-engineered blood vessels and cultivated in vitro under flow to assess the intimal response. Scanning electron microscopy, fluorescent nuclear staining with en face imaging, and histological assessments were performed 7 or 14 days postdeployment. Results illustrated accelerated cellular regeneration over protein-modified stent strut surfaces, with increased coverage and increased tissue thickness atop protein-modified stent struts. In addition, the intimal response to modified stents differed significantly from bare metal stents. Conclusions from this work support the use of a tissue-engineered blood vessel mimic system for evaluation of modified stent surfaces. These findings are important to stent researchers as well as laboratories developing tissue-engineered constructs.
Collapse
|
34
|
|
35
|
Will Intravascular OCT Shed Light on Vascular Biology? JACC Cardiovasc Imaging 2010; 3:85-7. [DOI: 10.1016/j.jcmg.2009.10.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2009] [Accepted: 10/29/2009] [Indexed: 11/17/2022]
|
36
|
Rodriguez-Menocal L, Wei Y, Pham SM, St-Pierre M, Li S, Webster K, Goldschmidt-Clermont P, Vazquez-Padron RI. A novel mouse model of in-stent restenosis. Atherosclerosis 2009; 209:359-66. [PMID: 19875114 DOI: 10.1016/j.atherosclerosis.2009.09.071] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2009] [Revised: 09/15/2009] [Accepted: 09/26/2009] [Indexed: 11/29/2022]
Abstract
BACKGROUND AND AIMS In-stent restenosis (ISR) is the major complication that occurs after percutaneous coronary interventions to facilitate coronary revascularization. Herein we described a simple and cost-effective model, which reproduces important features of ISR in the mouse. METHODS AND RESULTS Microvascular bare metal stents were successfully implanted in the abdominal aorta of atherosclerotic ApoE-null mice. Patency of implanted stents was interrogated using ultrasound biomicroscopy. Aortas were harvested at different time points after implantation and processed for histopathological analysis. Thrombus formation was histologically detected after 1 day. Leukocyte adherence and infiltration were evident after 7 days and decreased thereafter. Neointimal formation, neointimal thickness and luminal stenosis simultaneously increased up to 28 days after stent implantation. Using multichannel fluorescence molecular tomography (FMT) for spatiotemporal resolution of MMP activities, we observed that MMP activity in the stented aorta of Apo-E null mice was 2-fold higher than that of wild-type mice. Finally, we compared neointimal formation in response to stenting in two genetically different mouse strains. In-stent neointimas in FVB/NJ mice were 2-fold thicker than in C57BL/6J mice (p=0.002). CONCLUSION We have developed a model that can take advantage of the multiple genetic resources available for the mouse to study the mechanisms of in-stent restenosis.
Collapse
Affiliation(s)
- Luis Rodriguez-Menocal
- University of Miami Miller School of Medicine, 1600 NW 10th Avenue, RMSB 7147A, Miami, FL 33136, United States
| | | | | | | | | | | | | | | |
Collapse
|
37
|
Zilla P, Wolf M, Rafiee N, Moodley L, Bezuidenhout D, Black M, Human P, Franz T. Utilization of shape memory in external vein-graft meshes allows extreme diameter constriction for suppressing intimal hyperplasia: A non-human primate study. J Vasc Surg 2009; 49:1532-42. [DOI: 10.1016/j.jvs.2009.01.068] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2008] [Revised: 01/22/2009] [Accepted: 01/31/2009] [Indexed: 11/25/2022]
|
38
|
A practical method to rapidly dissolve metallic stents. Cardiovasc Pathol 2009; 18:127-33. [PMID: 19211268 DOI: 10.1016/j.carpath.2009.01.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2008] [Accepted: 01/05/2009] [Indexed: 10/21/2022] Open
Abstract
Metallic stents are commonly used in many clinical applications including peripheral vascular disease intervention, biliary obstruction, endovascular repair of aneurysms, and percutaneous coronary interventions. In the examination of vascular stent placement, it is important to determine if the stent is open or has become obstructed. This is increasingly important in the era of drug-eluting stent usage in coronary arteries. We describe a practical, rapid and cost-effective method to dissolve most metallic stents leaving the vascular and luminal tissues intact. This practical method may replace the laborious and expensive plastic embedding methods currently utilized.
Collapse
|
39
|
Zhang MZ, Li CL, Jiang YT, Jiang W, Sun Y, Shu R, Liang JP. Porphyromonas gingivalis infection accelerates intimal thickening in iliac arteries in a balloon-injured rabbit model. J Periodontol 2008; 79:1192-9. [PMID: 18597601 DOI: 10.1902/jop.2008.070425] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND Current epidemiologic data suggest that a localized infection (periodontitis) can disseminate into the distant tissues, and subgingival bacteria can migrate in the bloodstream, thereby contributing to independent systemic disease processes. To test this hypothesis, we investigated the effect of repeated systemic inoculations with Porphyromonas gingivalis (Pg) on intimal hyperplasia in iliac arteries in a rabbit model of balloon injury. METHODS One week after single balloon injury to the iliac artery, 30 male New Zealand rabbits were randomly assigned to intravenous inoculation with 100 microl live Pg (10(7) colony-forming units; n = 15) or vehicle (n = 15) once weekly for 4, 8, or 12 consecutive weeks. Arteries were fixed by perfusion and removed for analysis of neointimal lesion formation. We measured intimal and medial lesion areas in iliac artery cross-sections as well as the intimal/medial ratio (I/M). We also analyzed Pg 16S ribosomal DNA amplification with polymerase chain reaction, systemic proinflammatory mediators with enzyme-linked immunosorbent assay, and immunolocalization of macrophages in the balloon-injured arteries. RESULTS At 12 weeks, iliac intimal hyperplasia was accelerated, and I/M was significantly increased in Pg-inoculated animals (I/M 3.961 +/- 0.536 in the Pg group versus 3.585 +/- 0.353 in the control animals; P <0.01). Pg-inoculated animals also had significant increases in macrophage infiltration at 12 weeks, C-reactive protein levels at all time points, and interleukin-6 levels at 12 weeks. Moreover, Pg ribosomal DNA was found in the injured arteries of Pg-inoculated animals, but only after 12 weeks. CONCLUSION Long-term systemic challenge with Pg, an oral pathogen, may accelerate intimal hyperplasia in balloon-injured iliac arteries.
Collapse
Affiliation(s)
- Ming-Zhu Zhang
- Department of Endodontics and Operative Dentistry, The Ninth People's Hospital, School of Stomatology, Shanghai Jiaotong University, Shanghai, China
| | | | | | | | | | | | | |
Collapse
|
40
|
Constrictive external nitinol meshes inhibit vein graft intimal hyperplasia in nonhuman primates. J Thorac Cardiovasc Surg 2008; 136:717-25. [PMID: 18805277 DOI: 10.1016/j.jtcvs.2008.02.068] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2007] [Revised: 01/23/2008] [Accepted: 02/15/2008] [Indexed: 11/21/2022]
Abstract
OBJECTIVE External mesh support of vein grafts has been shown to mitigate the formation of intimal hyperplasia. The aim of the present study was to address the issue of optimal mesh size in a nonhuman primate model that mimics the dimensional mismatch typically encountered between clinical vein grafts and their target arteries. METHODS The effect of mesh size on intimal hyperplasia and endothelial preservation was assessed in bilateral femoral interposition grafts in Chacma baboons (n(Sigma) = 32/n = 8 per mesh size). No mesh support (group I) was compared with external nitinol meshes at three different sizes: loose fitting (group II), 25% diameter constricting (group III), and 50% diameter constricting (group IV). Mesh sizes were seen not only in isolation but also against the background of anastomotic size mismatch at implantation, expressed as quotient of cross-sectional area of host artery to vein graft (Q(C)). RESULTS Significant amounts of intimal hyperplasia were found in group I (Q(C) median 0.20; intimal hyperplasia 6 weeks = 1.63 +/- 0.34 mm(2); intimal hyperplasia 12 weeks = 1.73 +/- 0.5 mm(2)) and group II (Q(C) median 0.25; intimal hyperplasia 6 weeks = 1.96 +/- 1.64 mm(2); intimal hyperplasia 12 weeks = 2.88 +/- 1.69 mm(2)). In contrast, group III (Q(C) median 0.45; intimal hyperplasia 6 weeks = 0.08 +/- 0.13 mm(2); intimal hyperplasia 12 weeks = 0.18 +/- 0.32 mm(2)) and IV (Q(C) median 1.16; intimal hyperplasia 6 weeks = 0.02 +/- 0.03 mm(2); intimal hyperplasia 12 weeks = 0.11 +/- 0.10 mm(2)) showed dramatically suppressed intimal hyperplasia (P < .01) at both time points. Endothelial integrity was only preserved in group IV (P < .05). There were no significant differences in vascularization and inflammation in either interlayer or intergroup comparisons. CONCLUSION By using an animal model that addressed the clinical phenomenon of diameter discrepancy between vein graft and bypassed artery, we could demonstrate that suppression of intimal hyperplasia required constrictive mesh sizes.
Collapse
|
41
|
Abstract
Preparing and processing medical device implants for evaluation is a relatively high-risk and high-dollar process in which studies get made and endpoints can be lost with no second chance. It is important to customize every aspect of the preparation process to the type of device and the study endpoints. Some standard and proven approaches for a few types of implants are discussed, addressing fixation, special dissection and extraction techniques, preprocessing imaging, trimming techniques, sample processing, embedding media, and cutting and staining options.
Collapse
|
42
|
Zhang Q, Lu L, Pu L, Zhang R, Shen J, Zhu Z, Hu J, Yang Z, Chen Q, Shen W. Neointimal hyperplasia persists at six months after sirolimus-eluting stent implantation in diabetic porcine. Cardiovasc Diabetol 2007; 6:16. [PMID: 17550588 PMCID: PMC1892541 DOI: 10.1186/1475-2840-6-16] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2007] [Accepted: 06/05/2007] [Indexed: 11/16/2022] Open
Abstract
Background Observational clinical studies have shown that patients with diabetes have less favorable results after percutaneous coronary intervention compared with the non-diabetic counterparts, but its mechanism remains unclear. The aim of this study was to examine the changes of neointimal hyperplasia after sirolimus-eluting stent (SES) implantation in a diabetic porcine model, and to evaluate the impact of aortic inflammation on this proliferative process. Methods Diabetic porcine model was created with an intravenous administration of a single dose of streptozotocin in 15 Chinese Guizhou minipigs (diabetic group); each of them received 2 SES (Firebird, Microport Co, China) implanted into 2 separated major epicardial coronary arteries. Fifteen non-diabetic minipigs with SES implantation served as controls (control group). At 6 months, the degree of neointimal hyperplasia was determined by repeat coronary angiography, intravascular ultrasound (IVUS) and histological examination. Tumor necrosis factor (TNF)-α protein level in the aortic intima was evaluated by Western blotting, and TNF-α, interleukin (IL)-1β and IL-6 mRNA levels were assayed by reverse transcription and polymerase chain reaction. Results The distribution of stented vessels, diameter of reference vessels, and post-procedural minimal lumen diameter were comparable between the two groups. At 6-month follow-up, the degree of in-stent restenosis (40.4 ± 24.0% vs. 20.2 ± 17.7%, p < 0.05), late lumen loss (0.33 ± 0.19 mm vs. 0.10 ± 0.09 mm, p < 0.001) by quantitative angiography, percentage of intimal hyperplasia in the stented area (26.7 ± 19.2% vs. 7.3 ± 6.1%, p < 0.001) by IVUS, and neointimal area (1.59 ± 0.76 mm2 vs. 0.41 ± 0.18 mm2, p < 0.05) by histological examination were significantly exacerbated in the diabetic group than those in the controls. Significant increases in TNF-α protein and TNF-α, IL-1β and IL-6 mRNA levels were observed in aortic intima in the diabetic group. Conclusion Neointimal hyperplasia persisted at least up to 6 months after SES implantation in diabetic porcine, which may be partly related to an exaggerated inflammatory response within the blood vessel wall. Our results provide theoretical support for potential direct beneficial effects of anti-diabetic and anti-inflammation medications in reducing the risk of restenosis after stenting.
Collapse
Affiliation(s)
- Qi Zhang
- Department of Cardiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, PR China
| | - Lin Lu
- Department of Cardiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, PR China
| | - LiJin Pu
- Department of Cardiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, PR China
| | - RuiYan Zhang
- Department of Cardiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, PR China
| | - Jie Shen
- Department of Cardiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, PR China
| | - ZhengBing Zhu
- Department of Cardiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, PR China
| | - Jian Hu
- Department of Cardiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, PR China
| | - ZhenKun Yang
- Department of Cardiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, PR China
| | - QiuJin Chen
- Department of Cardiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, PR China
| | - WeiFeng Shen
- Department of Cardiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, PR China
| |
Collapse
|