1
|
Gong G, Zhang BN, Guo T, Liu G, Zhang J, Zhang XJ, Du X. Efficacy of orthokeratology lens with the modified small treatment zone on myopia progression and visual quality: a randomized clinical trial. EYE AND VISION (LONDON, ENGLAND) 2024; 11:35. [PMID: 39218909 PMCID: PMC11367740 DOI: 10.1186/s40662-024-00403-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Accepted: 08/05/2024] [Indexed: 09/04/2024]
Abstract
BACKGROUND To evaluate the long-term effectiveness of orthokeratology (ortho-K) lenses with small treatment zone (STZ) or conventional treatment zone (CTZ) in controlling axial elongation in children with myopia as well as the impact on visual quality. We also sought to determine the effect of retinal visual signal quality on axial elongation. METHODS This is a prospective randomized controlled study. A total of 140 participants (age ranging from 8 to 12 years) were randomly assigned to wear either STZ or CTZ ortho-K lenses. STZ ortho-K lenses design was achieved by changing the depth of reverse zone and the sagitta height of the optical zone. Using the IOL-Master 500, axial length (AL) was measured at baseline and after 6, 12 and 18 months of ortho-K treatment. Spherical aberration (SA) and corneal topographic parameters were obtained by the Pentacam anterior segment analyzer at baseline and the 1-month follow-up visit, and optical qualities were assessed by optical quality analysis system-II (OQAS-II) at baseline and after 1 month of lens wearing. Optical quality parameters mainly included the modulation transfer function (MTF) cutoff, Strehl ratio (SR), objective scattering index (OSI), and predicted visual acuity (PVA). RESULTS A total of 131 participants completed the study, including 68 in the STZ group and 63 in the CTZ group. The STZ group had significantly reduced AL elongation compared to the CTZ group after treatment (12 months: 0.07 ± 0.11 mm vs. 0.14 ± 0.12 mm, P = 0.002; 18 months: 0.17 ± 0.15 mm vs. 0.26 ± 0.16 mm, P = 0.002). The topography in the STZ group showed a smaller treatment zone (TZ) diameter (2.50 ± 0.23 mm vs. 2.77 ± 0.18 mm, P < 0.001), a wider defocus ring width (2.45 ± 0.28 mm vs. 2.30 ± 0.30 mm, P = 0.006), and larger values of total amount of defocus (119.38 ± 63.71 D·mm2 vs. 91.40 ± 40.83 D·mm2, P = 0.003) and total SA (0.37 ± 0.25 μm vs. 0.25 ± 0.29 μm, P = 0.015), compared with the CTZ group. Objective visual quality decreased in both groups (P < 0.001). This was evidenced by a greater decrease in MTF cutoff (- 14.24 ± 10.48 vs. - 10.74 ± 9.46, P = 0.047) and SR values (- 0.09 ± 0.07 vs. - 0.06 ± 0.07, P = 0.026), and an increase in OSI value (0.84 ± 0.72 vs. 0.58 ± 0.53, P = 0.019). PVA9% decreased significantly in the STZ group but not the CTZ group. A statistically significant negative correlation was found between the changes in total SA and MTF cutoff values (r = - 0.202, P = 0.025). AL changes were associated with sex, change of MTF cutoff value, increment of total SA and TZ area. CONCLUSIONS Compared with CTZ ortho-K lenses, STZ ortho-K lenses significantly inhibited axial elongation in children with myopia while moderately reducing their objective visual quality. Axial elongation was affected by retinal visual quality, and it may be a possible mechanism for ortho-K slowing myopia progression. Trial registration This trial is registered at Chinese Clinical Trial Registry on November 5, 2019 with trial registration number: ChiCTR1900027218. https://www.chictr.org.cn/showproj.html?proj=45380.
Collapse
Affiliation(s)
- Ganyu Gong
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, 5 Yanerdao Road, Qingdao, Shandong, 266071, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, Shandong, China
- School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China
| | - Bi Ning Zhang
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, 5 Yanerdao Road, Qingdao, Shandong, 266071, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, Shandong, China
- School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China
| | - Tengyou Guo
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, 5 Yanerdao Road, Qingdao, Shandong, 266071, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, Shandong, China
- School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China
| | - Guoying Liu
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, 5 Yanerdao Road, Qingdao, Shandong, 266071, China
| | - Ju Zhang
- Shandong First Medical, University& Shandong Academy of Medical Sciences, Jinan, Shandong, China
- Eye Institute of Shandong First Medical University, Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), Qingdao, Shandong, China
| | - Xiu Juan Zhang
- Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, China
- Joint Shantou International Eye Center of Shantou University and the Chinese University of Hong Kong, Shantou, Guangdong, China
| | - Xianli Du
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, 5 Yanerdao Road, Qingdao, Shandong, 266071, China.
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, Shandong, China.
- School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China.
| |
Collapse
|
2
|
Sullivan BD, Palazón de la Torre M, Yago I, Duarte R, Schallhorn JM, Nijm LM, White DE, Berg MS, Artal P. Tear Film Hyperosmolarity is Associated with Increased Variation of Light Scatter Following Cataract Surgery. Clin Ophthalmol 2024; 18:2419-2426. [PMID: 39224175 PMCID: PMC11366549 DOI: 10.2147/opth.s484840] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2024] [Accepted: 08/21/2024] [Indexed: 09/04/2024] Open
Abstract
Purpose To study the association between tear film hyperosmolarity and ocular light scatter in a cataract surgery population. Patients and Methods Contiguous, 20-second objective scatter index (OSI) scans were recorded in hyperosmolar (≥320 mOsm/L) and normal subjects (<308 mOsm/L) with cataract nuclear opacity ≥3. OSI was measured at screening, baseline and 90 days following surgery. Along with symptoms of ocular surface disease, slit-lamp examination included corneal staining (0-3), tear film breakup time (TBUT) and evaluation of meibomian gland disease (MGD). An additional cohort of hyperosmolar subjects were measured for OSI at screening, baseline, and 5, 10, 15 and 30 minutes following instillation of 0.18% sodium hyaluronate (HA). Results Thirty-one eyes of 31 patients were included. There was a significant difference in post-operative OSI variation when comparing hyperosmolar (0.65±0.30, N=11) to normal subjects (0.33±0.11, N=10, p=0.005). Of note, there were no significant differences in OSI variation when subjects were sorted by staining (p=0.9), TBUT (p=0.7), symptoms (p=0.7), or MGD status (p=0.9). Instillation of 0.18% HA (N=10) did not alter OSI at 5 minutes, but significant reductions in OSI of 28.8%, 38.5% and 36.7% (all p < 0.001) were observed at 10, 15 and 30 minutes. Conclusion Hyperosmolar patients exhibited significantly increased variation in light scatter following cataract surgery that was undifferentiated by staining or TBUT. Elevated osmolarity may be indicative of light scatter equivalent to that of a grade 2-3 cataract.
Collapse
Affiliation(s)
| | | | - Ines Yago
- Oftalmología en Murcia, Hospital Universitario Virgen de la Arrixaca, Murcia, Spain
| | - Raúl Duarte
- Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
| | - Julie M Schallhorn
- Francis I. Proctor Foundation and Department of Ophthalmology, University of California, San Francisco, CA, USA
| | - Lisa M Nijm
- Department of Ophthalmology and Visual Sciences, University of Illinois Eye and Ear Infirmary, Chicago, IL, USA
| | | | | | - Pablo Artal
- Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
| |
Collapse
|
3
|
Zhang H, Wu Q, Xu D, Wang J. Application of objective optical quality analysis system in guiding early posterior capsule opacification laser treatment: An observational study. Medicine (Baltimore) 2024; 103:e39386. [PMID: 39183412 PMCID: PMC11346832 DOI: 10.1097/md.0000000000039386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 04/29/2024] [Accepted: 07/31/2024] [Indexed: 08/27/2024] Open
Abstract
In the present study, we aimed to demonstrate the objective guiding role of objective scatter index (OSI) in patients with early stage posterior capsule opacification (PCO), especially in patients with multifocal intraocular lens (IOL) implantation. A prospective randomized case analysis was conducted on elderly patients experiencing PCO, exhibiting best-corrected visual acuity (BCVA) below 0.2 LogMAR. Exclusion criteria comprised patients with diabetes, glaucoma, high myopia, trauma, endothelial dystrophy, maculopathy or prior eye surgery affecting visual acuity. The main observational indicators were patient gender, age, post-cataract surgery duration, BCVA (LogMAR), and OSI values. For patients undergoing laser posterior capsulotomy, meticulous documentation of pre-laser OSI values and post-laser OSI values was undertaken. Subjective visual quality was then compared using the Chinese version visual function index-14 (VF-14-CN). The study comprised 65 eyes from 56 patients. PCO developed, on average, 2.06 ± 0.94 years (ranging from 0.5 to 4 years) after the initial surgery, with the OSI consistently exceeding 3.0. Among these cases, only 40 eyes underwent laser posterior capsulotomy using Nd:YAG laser, including 26 eyes implanted with monofocal IOLs and 14 eyes implanted with multifocal IOLs. Following laser posterior capsulotomy for early-stage secondary cataracts, there was a significant decrease in OSI values compared to the presurgery state, coupled with a notable increase in VF-14-CN scores. Among the 14 cases with multifocal IOL implantation, pre-laser VF-14-CN scores were lower compared to those with monofocal IOLs. Post-laser posterior capsulotomy, patients reported a marked improvement in self-perceived symptoms. The OQAS functioned as an objective assessment metric for the laser treatment of early stage PCO. In cases involving multifocal IOL implantation, the visual disturbance caused by PCO was more pronounced, underscoring the significance of OSI as a valuable guide for laser treatment in these patients.
Collapse
Affiliation(s)
- Hui Zhang
- Department of Ophthalmology, Jinan Second People’s Hospital, Jinan, China
| | - Qin Wu
- Department of Ophthalmology, Jinan Second People’s Hospital, Jinan, China
| | - Dongyan Xu
- Department of Ophthalmology, Jinan Second People’s Hospital, Jinan, China
| | - Jing Wang
- Department of Ophthalmology, Jinan Second People’s Hospital, Jinan, China
| |
Collapse
|
4
|
Craig JP, Barsam A, Chen C, Chukwuemeka O, Ghorbani-Mojarrad N, Kretz F, Michaud L, Moore J, Pelosini L, Turnbull AMJ, Vincent SJ, Wang MTM, Ziaei M, Wolffsohn JS. BCLA CLEAR Presbyopia: Management with corneal techniques. Cont Lens Anterior Eye 2024; 47:102190. [PMID: 38851946 DOI: 10.1016/j.clae.2024.102190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2024]
Abstract
Corneal techniques for enhancing near and intermediate vision to correct presbyopia include surgical and contact lens treatment modalities. Broad approaches used independently or in combination include correcting one eye for distant and the other for near or intermediate vision, (termed monovision or mini-monovision depending on the degree of anisometropia) and/or extending the eye's depth of focus [1]. This report reviews the evidence for the treatment profile, safety, and efficacy of the current range of corneal techniques for managing presbyopia. The visual needs and expectations of the patient, their ocular characteristics, and prior history of surgery are critical considerations for patient selection and preoperative evaluation. Contraindications to refractive surgery include unstable refraction, corneal abnormalities, inadequate corneal thickness for the proposed ablation depth, ocular and systemic co-morbidities, uncontrolled mental health issues and unrealistic patient expectations. Laser refractive options for monovision include surface/stromal ablation techniques and keratorefractive lenticule extraction. Alteration of spherical aberration and multifocal ablation profiles are the primary means for increasing ocular depth of focus, using surface and non-surface laser refractive techniques. Corneal inlays use either small aperture optics to increase depth of field or modify the anterior corneal curvature to induce corneal multifocality. In presbyopia correction by conductive keratoplasty, radiofrequency energy is applied to the mid-peripheral corneal stroma, leading to mid-peripheral corneal shrinkage and central corneal steepening. Hyperopic orthokeratology lens fitting can induce spherical aberration and correct some level of presbyopia. Postoperative management, and consideration of potential complications, varies according to technique applied and the time to restore corneal stability, but a minimum of 3 months of follow-up is recommended after corneal refractive procedures. Ongoing follow-up is important in orthokeratology and longer-term follow-up may be required in the event of late complications following corneal inlay surgery.
Collapse
Affiliation(s)
- Jennifer P Craig
- Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand; College of Health & Life Sciences, Aston University, Birmingham, UK.
| | | | - Connie Chen
- Department of Optometry, Chung Shan Medical University, Taichung City, Taiwan
| | - Obinwanne Chukwuemeka
- Cornea, Contact Lens and Myopia Management Unit, De-Lens Ophthalmics Family and Vision Care Centre, Abuja, Nigeria
| | - Neema Ghorbani-Mojarrad
- School of Optometry and Vision Science, University of Bradford, Bradford, UK; Wolfson Centre for Applied Health Research, Bradford Royal Infirmary, Bradford, UK
| | | | | | | | | | - Andrew M J Turnbull
- Royal Bournemouth Hospital, University Hospitals Dorset, UK; Faculty of Life and Health Sciences, Ulster University, UK
| | - Stephen J Vincent
- Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Australia
| | - Michael T M Wang
- Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Mohammed Ziaei
- Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - James S Wolffsohn
- Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand; College of Health & Life Sciences, Aston University, Birmingham, UK
| |
Collapse
|
5
|
Song D, Zhou L. The impact of dry eye disease on retinal image quality in children. Cont Lens Anterior Eye 2024; 47:102168. [PMID: 38641524 DOI: 10.1016/j.clae.2024.102168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 03/31/2024] [Accepted: 04/09/2024] [Indexed: 04/21/2024]
Abstract
BACKGROUND AND OBJECTIVES Dry eye disease (DED) is increasingly prevalent, resultinginhigher morbidityamong children. This study evaluates the impact of DED severity on visual quality using double-pass technology, focusing on dynamic observation of the ocular light scatter in pediatric DED cases. METHOD In this non-interventional, cross-sectional study, a mild DED group (37 cases, 37 eyes), a moderate DED group (40 cases, 40 eyes), and a control group of healthy children (35 cases, 35 eyes) were examined. Measurements included the Schirmer I test, tear film break-up time (BUT), and vision-related quality of life assessments using the Modified Ocular Surface Disease Index (OSDI) questionnaires. Participants underwent visual quality analysis using double-pass technology, which measured the modulation transfer function cut-off frequency value, Strehl ratio, objective scatter index (OSI), and OQAS-II value (OQAS-II value 100%, OQAS-II value 20%, and OQAS-II value 9%) under natural conditions. Additionally, dynamic changes in OSI post-blinking, Tear film mean-OSI , and the corresponding standard deviation OSI were recorded. RESULTS Statistically significant differences were observed among the groups in modulation transfer function cutoff, Strehl ratio, OSI, OQAS-II value 100 %, OQAs-II value 20 %, OQAs-II value 9 %, tear film mean OSI, and standard deviation OSI (P < 0.05). As DED severity increased, tear film mean OSI significantly rose, while modulation transfer function cutoff, strehl ratio, OQAS-II value 100 %, OQAS-II value 20 %, OQAS-II value 9 % notably declined. All optical quality parameters were correlated with BUT, with no association observed with age, sex, or Schirmer I test. CONCLUSION Dual-channel technology objectively assesses visual quality in pediatric DED, demonstrating that tear film scattering significantly affects retinal imaging and visual quality in children with DED.
Collapse
|
6
|
Vaughan M, García-Porta N, Tabernero J, Gantes-Nuñez J, Artal P, Pardhan S. Ocular effects of exposure to low-humidity environment with contact lens wear: A pilot study. Ophthalmic Physiol Opt 2024; 44:718-726. [PMID: 38551074 DOI: 10.1111/opo.13308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Revised: 03/13/2024] [Accepted: 03/16/2024] [Indexed: 05/01/2024]
Abstract
PURPOSE To compare the ocular effects of exposure to a low-humidity environment with and without contact lens (CL) wear using various non-invasive tests. METHODS Fourteen habitual soft CL wearers were exposed to controlled low humidity (5% relative humidity [RH]) in an environmental chamber for 90 min on two separate occasions. First, when wearing their habitual spectacles and then, on a separate visit, when wearing silicone hydrogel CLs that were fitted specifically for this purpose. All participants had adapted to the new CL prior to data collection. Three non-invasive objective measurements were taken at each visit: blinking rate, objective ocular scatter (measured using the objective scatter index) and ocular surface cooling rate (measured using a long-wave infrared thermal camera). At each visit, measurements were taken before the exposure in comfortable environmental conditions (RH: 45%), and after exposure to environmental stress (low humidity, RH: 5%). RESULTS CL wearers showed increased blinking rate (p < 0.005) and ocular scatter (p = 0.03) but similar cooling rate of the ocular surface (p = 0.08) when compared with spectacle wear in comfortable environmental conditions. The exposure to low humidity increased the blinking rate significantly with both types of corrections (p = 0.01). Interestingly, ocular scatter (p = 0.96) and cooling rate (p = 0.73) were not significantly different before and after exposure to low humidity. There were no significant two-way interactions between correction and exposure in any of the measurements. CONCLUSIONS CLs significantly increased the blinking rate, which prevented a quick degradation of the tear film integrity as it was refreshed more regularly. It is hypothesised that the increased blinking rate in CL wearers aids in maintaining ocular scatter quality and cooling rate when exposed to a low-humidity environment. These results highlight the importance of blinking in maintaining tear film stability.
Collapse
Affiliation(s)
- Megan Vaughan
- Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK
| | - Nery García-Porta
- Applied Physics Department, Optics and Optometry Faculty, University of Santiago de Compostela, Santiago, Spain
- Institute of Materials (iMATUS), University of Santiago de Compostela, Santiago, Spain
| | - Juan Tabernero
- Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK
- Department of Electromagnetism and Electronics, University of Murcia, Murcia, Spain
| | | | - Pablo Artal
- Laboratorio de Óptica, Centro de Investigación en Óptica y Nanofísica, Campus Espinardo, University of Murcia, Murcia, Spain
| | - Shahina Pardhan
- Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK
| |
Collapse
|
7
|
Fernández J, Burguera N, Rocha-de-Lossada C, Zamorano-Martín F, Rodríguez-Vallejo M. Screening of positive dysphotopsia before multifocal intraocular lens implantation. Indian J Ophthalmol 2024; 72:S211-S217. [PMID: 38271416 DOI: 10.4103/ijo.ijo_1038_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 09/26/2023] [Indexed: 01/27/2024] Open
Abstract
PURPOSE To assess the photic phenomena (PP) and positive dysphotopsia in candidates for presbyopia or cataract surgery and to evaluate their relationship with cataract grading systems. DESIGN Retrospective observational. METHODS Monocular data for 82 subjects measured during the preoperative screening were retrospectively retrieved from our database. The evaluated variables consisted of two methods for PP measurement: light distortion index (LDI) and parameters obtained from a simulator, both of which were combined with subjective bother related to PP. The cutoff for LDI that better predicted patients passing from slightly to moderately bothersome was estimated. The relationships between LDI and the following objective cataract grading methods were also assessed: objective scatter index (OSI), dysfunctional lens index (DLI), and Pentacam Nucleus Staging (PNS). RESULTS LDI was the best method for measuring PP, which showed a significant correlation with the bothersome question (rho = 0.34, P = 0.002) and also with OSI (rho = 0.67, P < 0.0005), DLI (rho = -0.29, P = 0.007), and PNS (rho = 0.48, P < 0.0005). The number/percentage of patients who found it bothersome was as follows: "Not at all" (18/22%), "Slightly" (41/50%), "Moderately" (15/18.3%), and "Very" (8/9.7%). The cutoff value that predicted the transition from slightly to moderately bothersome was ≥15.20% according to LDI, which could be estimated with the following values for grading: ≥2.8 for OSI, ≤7.6 for DLI, and ≥2 for PNS. CONCLUSIONS Patients reporting moderately or higher bothersome levels in the preoperative period and with LDI <15.20%, <2.8 for OSI, >7.6 for DLI, and <2 for PNS might deserve special attention in the multifocal intraocular lens selection.
Collapse
Affiliation(s)
- Joaquín Fernández
- Department of Ophthalmology, VITHAS Almería Hospital, Qvision, 04120, Almería, Spain
| | - Noemí Burguera
- Department of Ophthalmology, VITHAS Almería Hospital, Qvision, 04120, Almería, Spain
| | - Carlos Rocha-de-Lossada
- Department of Ophthalmology, VITHAS Almería Hospital, Qvision, 04120, Almería, Spain
- Ophthalmology Department, VITHAS Málaga, 29016 Málaga, Spain
- Hospital Regional Universitario de Málaga, Plaza del Hospital Civil, Spain
- Departamento de Cirugía, Universidad de Sevilla, Área de Oftalmología, Doctor Fedriani, Spain
| | | | | |
Collapse
|
8
|
Gupta A, Ruminski D, Villar AJ, Toledo RD, Gondek G, Pierscionek B, Artal P, Grulkowski I. Age-related changes in geometry and transparency of human crystalline lens revealed by optical signal discontinuity zones in swept-source OCT images. EYE AND VISION (LONDON, ENGLAND) 2023; 10:46. [PMID: 38037146 PMCID: PMC10691129 DOI: 10.1186/s40662-023-00365-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Accepted: 10/26/2023] [Indexed: 12/02/2023]
Abstract
BACKGROUND The shape and microstructure of the human crystalline lens alter with ageing, and this has an effect on the optical properties of the eye. The aim of this study was to characterise the age-related differences in the morphology and transparency of the eye lenses of healthy subjects through the optical signal discontinuity (OSD) zones in optical coherence tomography (OCT) images. We also investigated the association of those changes with the optical quality of the eye and visual function. METHODS OCT images of the anterior segment of 49 eyes of subjects (9-78 years) were acquired, and the OSD zones (nucleus, C1-C4 cortical zones) were identified. Central thickness, curvature and optical density were measured. The eye's optical quality was evaluated by the objective scatter index (OSI). Contrast sensitivity and visual acuity tests were performed. The correlation between extracted parameters and age was assessed. RESULTS The increase in lens thickness with age was dominated by the thickening of the cortical zone C3 (0.0146 mm/year). The curvature radii of the anterior lens surface and both anterior and posterior nucleo-cortical interfaces decreased with age (- 0.053 mm/year, - 0.013 mm/year and - 0.006 mm/year, respectively), and no change was observed for the posterior lens radius. OCT-based densitometry revealed significant correlations with age for all zones except for C1β, and the highest increase in density was in the C2-C4 zones (R = 0.45, 0.74, 0.56, respectively, P < 0.001). Increase in OSI was associated with the degradation of visual function. CONCLUSIONS OCT enables the identification of OSD zones of the crystalline lens. The most significant age-related changes occur in the C3 zone as it thickens with age at a faster rate and becomes more opaque than other OSD zones. The changes are associated with optical quality deterioration and reduction of visual performance. These findings contribute to a better understanding of the structure-function relationship of the ageing lens and offer insights into both pathological and aging alterations.
Collapse
Affiliation(s)
- Ashish Gupta
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziądzka 5, 87-100, Toruń, Poland
| | - Daniel Ruminski
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziądzka 5, 87-100, Toruń, Poland
| | - Alfonso Jimenez Villar
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziądzka 5, 87-100, Toruń, Poland
| | - Raúl Duarte Toledo
- Laboratorio de Óptica, Centro de Investigación en Óptica y Nanofísica, Universidad de Murcia, Edif. CIOyN, N º34, Campus de Espinardo, 30100, Murcia, Spain
| | - Grzegorz Gondek
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziądzka 5, 87-100, Toruń, Poland
| | - Barbara Pierscionek
- Faculty of Health, Education, Medicine, and Social Care, Medical Technology Research Center, Chelmsford Campus, Anglia Ruskin University, Bishop Hall Ln, Chelmsford, CM1 1SQ, UK
| | - Pablo Artal
- Laboratorio de Óptica, Centro de Investigación en Óptica y Nanofísica, Universidad de Murcia, Edif. CIOyN, N º34, Campus de Espinardo, 30100, Murcia, Spain
| | - Ireneusz Grulkowski
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziądzka 5, 87-100, Toruń, Poland.
| |
Collapse
|
9
|
Martino F, Castro-Torres JJ, Casares-López M, Ortiz-Peregrina S, Granados-Delgado P, Anera RG. Effects of alcohol consumption on driving performance in the presence of interocular differences simulated by filters. Sci Rep 2023; 13:17694. [PMID: 37848610 PMCID: PMC10582114 DOI: 10.1038/s41598-023-45057-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 10/15/2023] [Indexed: 10/19/2023] Open
Abstract
The role of interocular differences simulated by filters (fog filter and Bangerter foil) on visual and driving performance in alcohol users was assessed. We found that the binocular visual function deteriorates significantly in terms of contrast sensitivity (from 6 to 18 cpd). Additionally, driving performance is significantly impaired under these conditions as evidenced by increased mean speed, standard deviation of the lateral position, distance traveled outside the lane, reaction time and number of collisions. Furthermore, we found that interocular differences due to intraocular scattering and straylight are directly related to an overall reduction in visual and driving performance. This provided a comprehensive perspective from which to understand the relationship between binocular visual function, interocular differences, and driving performance. In practice, our findings contribute to the understanding of the importance of limiting interocular differences, which can be common among presbyopes corrected using the monovision technique, as well as in cases of cataract or other ocular pathology affecting only one eye, or even in cases of cataract surgery of the first eye. These interocular differences can have an adverse impact on road safety, especially when combined with moderate alcohol consumption.
Collapse
Affiliation(s)
- Francesco Martino
- Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics, University of Granada, Granada, Spain
| | - José J Castro-Torres
- Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics, University of Granada, Granada, Spain.
| | - Miriam Casares-López
- Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics, University of Granada, Granada, Spain
| | - Sonia Ortiz-Peregrina
- Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics, University of Granada, Granada, Spain
| | - Pilar Granados-Delgado
- Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics, University of Granada, Granada, Spain
| | - Rosario G Anera
- Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics, University of Granada, Granada, Spain
| |
Collapse
|
10
|
Huang H, Yan J, Li B, Huang M, Guo S, Fan A, Liu W. Tear Film Stability Affects Visual Acuity After Implantations of Monofocal and Multifocal Intraocular Lenses: An Evaluation by Objective Scatter Index. Transl Vis Sci Technol 2023; 12:15. [PMID: 37847201 PMCID: PMC10584023 DOI: 10.1167/tvst.12.10.15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Accepted: 09/14/2023] [Indexed: 10/18/2023] Open
Abstract
Purpose To assess the impact of tear film on postoperative visual acuity after cataract surgery to implant an intraocular lens (IOL). Methods Tear break-up time (TBUT), Schirmer I test, objective scatter index (OSI), and uncorrected distance visual acuity (UCDVA), intermediate visual acuity (UCIVA), and near visual acuity (UCNVA) were collected 6 months after cataract surgery. Results Fifteen eyes with monofocal (Mo-) IOLs and 15 eyes with multifocal (Mu-) IOLs from 30 subjects were included. The Mu-IOL group exhibited higher baseline OSI (1.92 ± 0.69, P < 0.001). Negative correlations-both groups: tear film-related OSI (TF-OSI) and TBUT/Schirmer I test; Mo-IOL: TBUT and logMAR UCDVA-and positive correlations-both groups: TF-OSI and baseline OSI, baseline OSI/TF-OSI and logMAR UCDVA; Mu-IOL: baseline OSI/TF-OSI and logMAR UCIVA/UCNVA-were found. Linear regression showed associations between TF-OSI and TBUT (Mo-IOL: R2 = 0.455, P = 0.006; Mu-IOL: R2 = 0.454, P = 0.006)/Schirmer I test (Mo-IOL: R2 = 0.527, P = 0.002; Mu-IOL: R2 = 0.266, P = 0.049). Multiple regression showed associations between baseline OSI (Mo-IOL: R2 = 0.309, P = 0.032; Mu-IOL: R2 = 0.305, P = 0.033)/TF-OSI (Mo-IOL: R2 = 0.332, P = 0.025; Mu-IOL: R2 = 0.523, P = 0.002)/TBUT (Mo-IOL only: R2 = 0.315, P = 0.029) and logMAR UCDVA. Conclusions TF-OSI reflects the UCDVA performance in eyes with IOLs and facilitates a better understanding of the effects of the tear film. Translational Relevance TF-OSI offers a developmental and objective approach to assessing the changing visual performance caused by tear film after cataract surgery and IOL implantation in clinical practices.
Collapse
Affiliation(s)
- Hao Huang
- Department of Ophthalmology, Zhuzhou Hospital Affiliated to Xiangya School of Medicine, Central South University, Zhuzhou, China
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science; Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Jianjun Yan
- Department of Ophthalmology, Zhuzhou Hospital Affiliated to Xiangya School of Medicine, Central South University, Zhuzhou, China
| | - Bowen Li
- Eye Center of Xiangya Hospital, Central South University, Changsha, China
| | - Mansha Huang
- Guangzhou Aier Eye Hospital, Jinan University, Guangzhou, China
| | - Shuanglin Guo
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science; Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Aifang Fan
- Department of Ophthalmology, Zhuzhou Hospital Affiliated to Xiangya School of Medicine, Central South University, Zhuzhou, China
| | - Wei Liu
- Department of Ophthalmology, Zhuzhou Hospital Affiliated to Xiangya School of Medicine, Central South University, Zhuzhou, China
| |
Collapse
|
11
|
Sánchez RF, Puertas FJ, Issolio LA. Modulation transfer function formula for different age ranges. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2023; 40:1979-1985. [PMID: 37855554 DOI: 10.1364/josaa.494721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Accepted: 09/19/2023] [Indexed: 10/20/2023]
Abstract
The modulation transfer function (MTF) is one of the most complete tools to study the optical performance of the eye. We present the average radial MTF profiles measured in 68 subjects grouped in six age ranges (from 20 to 80 years) and a general formula to estimate the radial profile of human MTF as a function of pupil size and age. The mean MTF for each age group was fitted to an analytical expression to compute two parameters related to aging. The proposed formula fitted reasonably well to experimental data available in previous works and predicted the average changes with aging of different optical quality parameters obtained from MTF.
Collapse
|
12
|
Mencucci R, Morelli A, Cennamo M, Roszkowska AM, Favuzza E. Enhanced Monofocal Intraocular Lenses: A Retrospective, Comparative Study between Three Different Models. J Clin Med 2023; 12:jcm12103588. [PMID: 37240694 DOI: 10.3390/jcm12103588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 05/16/2023] [Accepted: 05/19/2023] [Indexed: 05/28/2023] Open
Abstract
The purpose of this study was to compare the visual performance and optical quality between three new enhanced monofocal intraocular lenses (IOLs). This retrospective study included patients affected by cataracts with corneal astigmatism less than 0.75 D and no ocular comorbidities who underwent cataract surgery with bilateral implantation of Tecnis Eyhance ICB00 (Johnson & Johnson Vision Care, Inc., Jacksonville, FL, USA), Vivinex Impress XY1-EM (Hoya Surgical Optics, Singapore) or IsoPure 123 (PhysIOL, Liege, Belgium) IOLs. Three months postoperatively, monocular and binocular uncorrected and corrected distant, and intermediate and near visual acuities were measured. Binocular defocus curve, photopic contrast sensitivity, Point Spread Function (PSF), low order aberrations (LOAs), high order aberrations (HOAs), objective scatter index (OSI), halo and glare perception were also evaluated. This study included a total of 72 eyes from 36 patients. Visual acuity outcomes, PSF, LOAs, HOAs and OSI were similar between groups. There were no statistically significant differences in terms of photopic contrast sensitivity, halo or glare perception. In patients without ocular comorbidities, the Eyhance ICB00 IOL, the Vivinex Impress IOL and the Isopure IOL-even though based on different optical properties-provided similar results in terms of visual acuity, contrast sensitivity and intraocular aberrations, with no influence on photic phenomena.
Collapse
Affiliation(s)
- Rita Mencucci
- Eye Clinic, Careggi Hospital, Department of Neurosciences, Psychology, Pharmacology and Child Health (NEUROFARBA), University of Florence, 50134 Florence, Italy
| | - Alberto Morelli
- Eye Clinic, Careggi Hospital, Department of Neurosciences, Psychology, Pharmacology and Child Health (NEUROFARBA), University of Florence, 50134 Florence, Italy
| | - Michela Cennamo
- Eye Clinic, Careggi Hospital, Department of Neurosciences, Psychology, Pharmacology and Child Health (NEUROFARBA), University of Florence, 50134 Florence, Italy
| | - Anna Maria Roszkowska
- Ophthalmology Clinic, Department of Biomedical Sciences, University of Messina, 98100 Messina, Italy
| | - Eleonora Favuzza
- Eye Clinic, Careggi Hospital, Department of Neurosciences, Psychology, Pharmacology and Child Health (NEUROFARBA), University of Florence, 50134 Florence, Italy
| |
Collapse
|
13
|
Pan AP, Ma Y, Hu R, Cao X, Wu Y, Zhou K, Tu R, Shao X, Chen S, Yu AY. Simultaneous real-time analysis of tear film optical quality dynamics and functional visual acuity in dry eye disease. EYE AND VISION (LONDON, ENGLAND) 2023; 10:16. [PMID: 37005660 PMCID: PMC10068140 DOI: 10.1186/s40662-023-00333-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Accepted: 02/15/2023] [Indexed: 04/04/2023]
Abstract
BACKGROUND To assess the effect of tear film instability in dry eye disease (DED) by measuring visual performance and tear film optical quality in a simultaneous real-time analysis system. METHODS Thirty-seven DED participants and 20 normal controls were recruited. A simultaneous real-time analysis system was developed by adding a functional visual acuity (FVA) channel to a double-pass system. Repeated measurements of FVA and objective scatter index (OSI) were performed simultaneously with this system under blink suppression condition for 20 s. Patient-reported symptoms was evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. Mean FVA, mean OSI, and visual acuity break-up time were defined. The OSI maintenance ratio was calculated as an evaluation index to assess the difference between dynamic OSI changes and baseline OSI. The visual maintenance ratio was also calculated in the same way. RESULTS Moderate correlations were noted between mean OSI and FVA-related parameters (mean FVA, visual maintenance ratio, visual acuity break-up time: 0.53, - 0.56, - 0.53, respectively, P < 0.01 for all). Moderate to high correlations were noted between OSI maintenance ratio and FVA-related parameters (mean FVA, visual maintenance ratio, visual acuity break-up time: - 0.62, 0.71, 0.64, respectively, all P < 0.01). The metrics derived from the simultaneous real-time analysis system were moderately correlated with the patient-reported symptoms and the visual acuity break-up time possessed the highest correlation coefficients with OSDI total, ocular symptoms, and vision-related function (- 0.64, - 0.63, - 0.62, respectively, P < 0.01). The OSI-maintenance ratio alone appeared to exhibit the best performance of the metrics for the detection of DED with sensitivity of 95.0% and specificity of 83.8% and the combinations of FVA parameters and OSI parameters were valid and can further improve the discriminating abilities. CONCLUSIONS OSI-related metrics were found to be potential indicators for assessing and diagnosing DED which correlated with both subjective visual performance and patient-reported symptoms; the FVA-related metrics were quantifiable indicators for evaluating visual acuity decline in DED. TRIAL REGISTRATION NUMBER Chinese Clinical Trial Registry, ChiCTR2100051650. Registered 29 September 2021, https://www.chictr.org.cn/showproj.aspx?proj=134612.
Collapse
Affiliation(s)
- An-Peng Pan
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, 270 Xueyuan West Road, Wenzhou, 325027, Zhejiang, China
| | - Yunjing Ma
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, 270 Xueyuan West Road, Wenzhou, 325027, Zhejiang, China
| | - Ruilin Hu
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, 270 Xueyuan West Road, Wenzhou, 325027, Zhejiang, China
| | - Xuejiao Cao
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, 270 Xueyuan West Road, Wenzhou, 325027, Zhejiang, China
| | - Yifen Wu
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, 270 Xueyuan West Road, Wenzhou, 325027, Zhejiang, China
| | - Kaijing Zhou
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, 270 Xueyuan West Road, Wenzhou, 325027, Zhejiang, China
| | - Ruixue Tu
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, 270 Xueyuan West Road, Wenzhou, 325027, Zhejiang, China
| | - Xu Shao
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, 270 Xueyuan West Road, Wenzhou, 325027, Zhejiang, China
| | - Shihao Chen
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, 270 Xueyuan West Road, Wenzhou, 325027, Zhejiang, China
| | - A-Yong Yu
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, 270 Xueyuan West Road, Wenzhou, 325027, Zhejiang, China.
| |
Collapse
|
14
|
Villanueva C, Viviano F, García-Montero M, Lorente-Velázquez A, Martínez-Alberquilla I, Garzón N. Forward-scattered and backward-scattered light in moderate keratoconus. Ophthalmic Physiol Opt 2023. [PMID: 36920155 DOI: 10.1111/opo.13126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 02/17/2023] [Accepted: 03/01/2023] [Indexed: 03/16/2023]
Abstract
INTRODUCTION To evaluate the backscattered light, objective scatter index (OSI) and retinal straylight in patients with moderate keratoconus and healthy control subjects. METHODS A prospective observational study was developed with 33 patients in the moderate-keratoconus group (KC) and 34 in the non-keratoconus group (NKC). Corneal densitometry was obtained using Scheimpflug corneal tomography and measurements were expressed in grayscale units (GSU) over four zones within a 12.00 mm diameter around the corneal apex. A straylight meter was used to determine the amount of intraocular straylight under scotopic conditions, and the straylight parameter (LOG(s)) and test duration were recorded. The Optical Quality Analysis System based on the double-pass technique determined the OSI value. RESULTS Significant differences were observed between the KC and NKC groups for corneal densitometry (except in the 6-10 mm zone), OSI and retinal straylight. A moderate and significant correlation was found between OSI and retinal straylight LOG(s) (r = 0.52, p = 0.002). Weaker and non-significant correlations were found between corneal densitometry and the other parameters analysed (i.e., OSI, retinal straylight LOG(s) and retinal straylight times). CONCLUSIONS Backscattered light, retinal straylight and the OSI show clear differences between healthy eyes and those with moderate KC. The changes present in the stages of KC evaluated in the current study (stages II and III according to the Amsler-Krumeich classification) might alter the scattering of the light entering the eye.
Collapse
Affiliation(s)
- Celia Villanueva
- Optometry and Vision Department, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Madrid, Spain.,Ophthalmology Department, Hospital Clínico San Carlos, Madrid, Spain
| | - Francesco Viviano
- Optometry and Vision Department, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Madrid, Spain
| | - María García-Montero
- Optometry and Vision Department, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Madrid, Spain
| | - Amalia Lorente-Velázquez
- Optometry and Vision Department, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Madrid, Spain
| | - Irene Martínez-Alberquilla
- Optometry and Vision Department, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Madrid, Spain
| | - Nuria Garzón
- Optometry and Vision Department, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Madrid, Spain
| |
Collapse
|
15
|
Early Impact of Laser Vision Correction (LVC) on the Stability and Quality of the Retinal Image. J Clin Med 2023; 12:jcm12051779. [PMID: 36902566 PMCID: PMC10002574 DOI: 10.3390/jcm12051779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 02/18/2023] [Accepted: 02/20/2023] [Indexed: 02/25/2023] Open
Abstract
This retrospective comparative study analyzes the early postoperative impact of laser vision correction for myopia on the optical quality and stability of functional vision using a double-pass aberrometer. Retinal image quality and visual function stability were assessed preoperatively, one and three months after myopic laser in situ keratomileuses (LASIK) and photorefractive keratectomy (PRK) using double-pass aberrometry (HD Analyzer, Visiometrics S.L, Terrassa, Spain). The parameters analyzed included vision break-up time (VBUT), objective scattering index (OSI), modulation transfer function (MTF), and Strehl ratio (SR). The study included 141 eyes of 141 patients, of whom 89 underwent PRK and 52 underwent LASIK. No statistically significant differences were noted between the two techniques in any analyzed parameters at three months postoperatively. However, a significant drop was observed in all parameters one month after PRK. Only the OSI and VBUT remained significantly altered from baseline at the three months follow-up visit, with an increased OSI by 0.14 +/- 0.36 (p < 0.01) and a shortened VBUT by 0.57 +/- 2.3 s (p < 0.01). No correlation was found between the changes in optical and visual quality parameters and age, ablation depth, or postoperative spherical equivalent. The stability and quality of the retinal images were similar between LASIK and PRK at three months postoperatively. However, significant degradation in all parameters was found one month after PRK.
Collapse
|
16
|
Martino F, Castro-Torres JJ, Casares-López M, Ortiz-Peregrina S, Granados-Delgado P, Jiménez JR. Influence of Interocular Differences and Alcohol Consumption on Binocular Visual Performance. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:1751. [PMID: 36767115 PMCID: PMC9914044 DOI: 10.3390/ijerph20031751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 01/14/2023] [Accepted: 01/16/2023] [Indexed: 06/18/2023]
Abstract
The purpose of this study was to assess the influence of a moderate breath-alcohol content (BrAC of 0.40 mg/L) on binocular visual performance for different visual functions after inducing different levels of interocular differences with the use of filters. A total of 26 healthy young subjects were enrolled. The participants participated in two sessions: one without alcohol consumption and another after alcohol consumption. In each session and for the different filter conditions (subjects were wearing Bangerter foil of 0.8 and BPM2 fog filter on the dominant eye), monocular and binocular visual function was evaluated by measuring visual acuity, contrast sensitivity, visual discrimination capacity (and successively by calculating their corresponding binocular summations) and stereopsis (near and distance stereoacuity). In addition, interocular differences were calculated for different retinal-image quality and straylight parameters. All monocular and binocular visual functions were analyzed and stereopsis was significantly impaired by alcohol and filters (p < 0.05). Interocular differences for different ocular parameters and binocular summations for visual parameters were negatively affected by filters but not alcohol. Significant correlations (averaging all the experimental conditions analyzed) were found, highlighting: the higher the interocular differences, the lower the binocular summation and the poorer the stereopsis and, therefore, the worse the binocular visual performance.
Collapse
|
17
|
Lu W, Song G, Zhang Y, Lian Y, Ma K, Lu Q, Jin Y, Zhao Y, Zhang S, Lv F, Jin W. The effect of orthokeratology lenses on optical quality and visual function in children. Front Neurosci 2023; 17:1142524. [PMID: 37123367 PMCID: PMC10140410 DOI: 10.3389/fnins.2023.1142524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 03/27/2023] [Indexed: 05/02/2023] Open
Abstract
Purpose To assess changes in optical quality and visual function in children after 3 months of wearing orthokeratology (OK) lenses. Methods A total of 25 myopic children aged 8-12 years were recruited and completed the follow-up study. Optical quality, visual function and corneal morphology were assessed at baseline and at follow-ups 1 and 3 months after wearing OK lenses. Optical quality parameters mainly included the modulation transfer function (MTF) cutoff, objective scattering index (OSI), Strehl ratio (SR) and the predicted visual acuities (PVAs). Visual function was assessed by visual acuity, monocular contrast sensitivity function (CSF) across five spatial frequencies and the area under the log contrast sensitivity function (AULCSF) that was also computed as an index for overall CSF. Results The MTF cutoff and SR values both increased after 1 month of wearing the OK lenses (baseline vs. 1 month: P MTF = 0.008 and P SR = 0.049); this improvement plateaued after 3 months of lens wear (1 month vs. 3 months: P MTF = 0.626, P SR = 0.428). The corneal morphology also showed the similar change trend. The OSI showed the opposite change trend (baseline vs. 1 month: P OSI < 0.001; 1 month vs. 3 months: P OSI = 0.720). The mean CSF at 1.5 cpd decreased significantly after 1 month of wearing the lenses (baseline vs. 1 month: p = 0.001) and recovered after 3 months of lens wear (baseline vs. 3 months: p = 0.076). CSF at spatial frequencies of 3, 6, 12 and 18 cpd as well as the AULCSF did not significantly differ between any two timepoints (all Ps > 0.05). Conclusion After 3 months of wearing OK lenses, the subjects exhibited a decrease in optical quality, similar to corneal morphology, whereas their visual function remained largely unchanged. Thus, the optical quality was more susceptible to OK lenses than visual function in children. The initial month of OK treatment of children is a key period to be paid close attention to deterioration of optical quality and visual function.
Collapse
Affiliation(s)
- Weiwei Lu
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - Guanxin Song
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - Yuhan Zhang
- Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, Shenyang, China
| | - Yan Lian
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - Ke Ma
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - Qingqing Lu
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - Yiyu Jin
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - Yang Zhao
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - Shuyu Zhang
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - Fan Lv
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China
- *Correspondence: Fan Lv,
| | - Wanqing Jin
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China
- Wanqing Jin,
| |
Collapse
|
18
|
Li Y, Jin L, Wu M, Huang Y. Evaluation value of subjective visual quality examination on surgical indications of the early cataracts based on objective scatter index values. Front Med (Lausanne) 2022; 9:1075693. [PMID: 36582278 PMCID: PMC9792837 DOI: 10.3389/fmed.2022.1075693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 11/14/2022] [Indexed: 12/14/2022] Open
Abstract
Aim To evaluate the subjective visual functions of early cataracts patients and assess their surgical indications. Methods Eyes were separated into a control group (Group A without cataract) and two early cataracts groups (Group B with 2.0 ≤ OSI < 3.0 and Group C with 3.0 ≤ OSI < 4.0). The objective scatter index (OSI), modulation transfer function cut-off frequency (MTF cut-off), and Strehl ratio (SR) values were applied to measure objective visual functions. The contrast sensitivity (CS) and scores of the questionnaires (QOL and VF-14) characterized subjective visual functions. Above visual functions were compared among three groups. Postoperative visual functions in Group B and C were analyzed to assess the outcome of surgery. Results Ninety two subjects (126 eyes) were included in the study. All objective visual function in Group B were significantly better than Group C (all P < 0.01), but worse than Group A (all P < 0.01). Except for 1.5 c/d CS, subjective visual function in Group A were significantly better than Group B and C (all P < 0.05), but there was no significant differences between Group B and C. As for eyes that underwent surgery in Group B and C, all visual functions significantly improved after surgery (P < 0.05), except for 1.5 c/d CS in Group C. There were no significant differences among the three groups after surgery. Conclusion The subjective visual function can be impaired in early cataracts patients with OSI < 3.0, whose objective visual functions were statistically better than patients with OSI ≥ 3.0. These patients can benefit equally from surgery as patients with OSI ≥ 3.0. Subjective visual functions can be used as surgical indications for these patients.
Collapse
|
19
|
Delbarre M, Crepy P, Froussart-Maille F. Keratoconus and Fitness to Fly. Aerosp Med Hum Perform 2022; 93:840-845. [PMID: 36757242 DOI: 10.3357/amhp.6050.2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
BACKGROUND: Of the body senses, vision is the most important for safe flight. Keratoconus causes progressive blurring and distortion of vision, which threatens the career of a civilian or military aviator. The goal of this retrospective study was to describe a series of keratoconus cases in a pilot population and to discuss decisions about their flight waivers.METHODS: To assess the impact of keratoconus on flying careers, we reviewed the records of all aviators with keratoconus examined in an Aeromedical Center over the past 5 yr.RESULTS: The files of 19 pilots [13 line pilots and 6 military pilots (3 fighter pilots)] were collected and analyzed. Of the 19 patients, 2 did not obtain flight fitness waivers. Among the 17 who received waivers, correction for defective distant vision (glasses or contact lenses) was imposed on 5 aviators.DISCUSSION: Keratoconus is a medical condition with aeromedical significance that should be detected by aeromedical examiners. A flight license can only be considered if the disease is stable and with satisfactory visual quality. Double pass aberrometry may be helpful to determine flight fitness. This study shows that keratoconus is not always a disability for aviators. Most of them are able to continue their flying careers safely. However, it must be analyzed on a case-by-case basis.Delbarre M, Crepy P, Froussart-Maille F. Keratoconus and fitness to fly. Aerosp Med Hum Perform. 2022; 93(12):840-845.
Collapse
|
20
|
Mota DF, Haddad JS, Rocha KM, George Oral Waring IV, Tanos FW, Ambrosio R. The role of the tear film in dysfunctional lens syndrome: a prospective review. REVISTA BRASILEIRA DE OFTALMOLOGIA 2022. [DOI: 10.37039/1982.8551.20220063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
21
|
Kaspi M, Grivet D, Thuret G, Gain P, Garcin T. Corrélations entre mesures subjectives et objectives préopératoires de la sévérité d’une cataracte, et la quantité d’ultrasons peropératoires. J Fr Ophtalmol 2022; 45:e346-e350. [DOI: 10.1016/j.jfo.2022.02.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 02/14/2022] [Accepted: 02/14/2022] [Indexed: 10/18/2022]
|
22
|
Hou XW, Wang Y, Wu Q, Ke C, Pan CW. A review of study designs and data analyses in metabolomics studies in myopia. Anal Biochem 2022; 655:114850. [PMID: 35970413 DOI: 10.1016/j.ab.2022.114850] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Revised: 07/15/2022] [Accepted: 08/03/2022] [Indexed: 11/25/2022]
Abstract
Metabolomics analyzes the entire range of small molecule metabolites in biological systems to reveal the response signals that are transmitted from "genetics and environment", which could help us understand complex phenotypes of diseases. Metabolomics has been successfully applied to the study of eye diseases including age-related macular degeneration, glaucoma, and diabetic retinopathy. In this review, we summarize the findings of myopic metabolomics and discuss them from a design and analysis perspective. Finally, we provide new ideas for the future development of myopia metabolomics research based on the broader ocular metabolomics study.
Collapse
Affiliation(s)
- Xiao-Wen Hou
- School of Public Health, Medical College of Soochow University, Suzhou, China
| | - Ying Wang
- School of Public Health, Medical College of Soochow University, Suzhou, China
| | - Qian Wu
- School of Public Health, Medical College of Soochow University, Suzhou, China
| | - Chaofu Ke
- School of Public Health, Medical College of Soochow University, Suzhou, China
| | - Chen-Wei Pan
- School of Public Health, Medical College of Soochow University, Suzhou, China.
| |
Collapse
|
23
|
Montani G, Landini L, Martino M. Short- and long-term effects of a multi-component, artificial tear on preocular tear film stability, tear evaporation and tear film optical dynamic: a prospective randomized double-phase study. Curr Eye Res 2022; 47:1252-1258. [PMID: 35749148 DOI: 10.1080/02713683.2022.2093381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
AIM To evaluate the short- (within 90 minutes) and long-term (after 21 days of treatment) effects of an artificial tear containing carbomer, hyaluronic acid, glycerol, and medium-chain triglycerides in patients with mild-to-moderate dry eye symptoms. PATIENTS AND METHODS Subjects received the tested artificial tears in the right eye and control artificial tears in the left eye and were assessed 10, 30, 60, and 90 minutes after instillation in the short-term study phase. They received the study product in both eyes in the long-term phase. Non-invasive break-up time (NIBUT), tear lipid layer pattern, tear evaporation, and tear film objective optical dynamics (TFOOD) were measured in controlled environmental conditions. RESULTS In total, 32 patients (10 males, mean age 42 ± 11 years) were enrolled. During the short-term phase, NIBUT increased significantly in the right eyes at all time points compared with baseline (all p < 0.05). Conversely, in the left eyes, NIBUT increased significantly at 10 and 30 min (p < 0.05). The tear evaporation values increased at 10 minutes and decreased at 30 and 60 minutes (p < 0.05) in the right eyes, while they increased only at 10 minutes (p < 0.05) in the left eyes. Compared with baseline, the TFOOD was significantly more stable at all time points in the right eyes (p < 0.05), while it was more stable at 10 and 30 min in the left eyes (p < 0.05). In the long-term phase, treated eyes showed a significant increase in NIBUT values, a significant reduction of tear evaporation, a significant improvement of tear lipid layer pattern, and a more stable TFOOD compared with baseline (all p < 0.05). Symptoms, measured with the Ocular Surface Disease Index questionnaire, were also significantly reduced compared with baseline (p < 0.05). CONCLUSION The tested product increased tear film stability and reduced tear evaporation, normalizing lipid layer pattern and reducing symptoms in the short- and long-term observation.
Collapse
Affiliation(s)
- Giancarlo Montani
- Mathematics and Physics Department "Ennio De Giorgi," Salento University, Lecce, Italy.,Ce.R.C.A. Salento University, Lecce, Italy
| | | | - Maurizio Martino
- Mathematics and Physics Department "Ennio De Giorgi," Salento University, Lecce, Italy.,Ce.R.C.A. Salento University, Lecce, Italy
| |
Collapse
|
24
|
Li W, Cao Y, Zhou J. Effects of low-concentration atropine eye drops on the optical quality of the eyes in myopic children. Indian J Ophthalmol 2022; 70:2107-2110. [PMID: 35647992 PMCID: PMC9359241 DOI: 10.4103/ijo.ijo_2886_21] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Purpose: The present study was performed to compare the optical quality of the eyes of myopic children before and after treatment with atropine eye drops of different concentrations. Methods: In the study population of 71 patients (131 eyes), 34 patients (63 eyes) were given 0.01% atropine eye drops and 37 patients (68 eyes) were given 0.05% atropine eye drops. The modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and predicted visual acuities (PVAs 100%, 20%, and 9%) under different lighting conditions were measured before and after two weeks of atropine treatment. Results: After using 0.05% atropine eye drops for two weeks, the Strehl ratio decreased from 0.27 ± 0.07 to 0.23 ± 0.07 (P = 0.0026), PVA 20% decreased from 1.15 ± 0.32 to 1.03 ± 0.36 (P = 0.0344), and PVA 9% decreased from 0.74 ± 0.23 to 0.64 ± 0.23 (P = 0.0073). The OSI was significantly higher after using 0.05% than 0.01% atropine eye drops (P = 0.0396), while both the Strehl ratio and PVA 20% were lower after using 0.05% than 0.01% atropine eye drops (P = 0.0087 and P = 0.0492, respectively). Conclusion: The children’s optical quality did not change significantly after using 0.01% atropine eye drops, whereas it decreased after using 0.05% atropine eye drops.
Collapse
Affiliation(s)
- Weiran Li
- Department of Ophthalmology, Ninth People's Hospital, Shanghai JiaoTong University School of Medicine; Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Yiting Cao
- Department of Ophthalmology, Ninth People's Hospital, Shanghai JiaoTong University School of Medicine; Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Jibo Zhou
- Department of Ophthalmology, Ninth People's Hospital, Shanghai JiaoTong University School of Medicine; Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| |
Collapse
|
25
|
Martínez-Plaza E, Ruiz-Fortes P, Soto-Negro R, Hernández-Rodríguez CJ, Molina-Martín A, Arias-Puente A, Piñero DP. Characterization of Dysfunctional Lens Index and Opacity Grade in a Healthy Population. Diagnostics (Basel) 2022; 12:diagnostics12051167. [PMID: 35626322 PMCID: PMC9140515 DOI: 10.3390/diagnostics12051167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Revised: 05/05/2022] [Accepted: 05/06/2022] [Indexed: 11/28/2022] Open
Abstract
This study enrolled 61 volunteers (102 eyes) classified into subjects < 50 years (group 1) and subjects ≥ 50 years (group 2). Dysfunctional Lens Index (DLI); opacity grade; pupil diameter; and corneal, internal, and ocular higher order aberrations (HOAs) were measured with the i-Trace system (Tracey Technologies). Mean DLI was 8.89 ± 2.00 and 6.71 ± 2.97 in groups 1 and 2, respectively, being significantly higher in group 1 in all and right eyes (both p < 0.001). DLI correlated significantly with age (Rho = −0.41, p < 0.001) and pupil diameter (Rho = 0.20, p = 0.043) for all eyes, and numerous internal and ocular root-mean square HOAs for right, left, and all eyes (Rho ≤ −0.25, p ≤ 0.001). Mean opacity grade was 1.21 ± 0.63 and 1.48 ± 1.15 in groups 1 and 2, respectively, with no significant differences between groups (p ≥ 0.29). Opacity grade significantly correlated with pupil diameter for right and all eyes (Rho ≤ 0.33, p ≤ 0.013), and with some ocular root-mean square HOAs for right and all eyes (Rho ≥ 0.23, p ≤ 0.020). DLI correlates with age and might be used complementary to other diagnostic measurements for assessing the dysfunctional lens syndrome. Both DLI and opacity grade maintain a relationship with pupil diameter and internal and ocular HOAs, supporting that the algorithms used by the device may be based, in part, on these parameters.
Collapse
Affiliation(s)
- Elena Martínez-Plaza
- Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, 03690 Alicante, Spain; (E.M.-P.); (C.J.H.-R.); (A.M.-M.)
- University of Valladolid, 47002 Valladolid, Spain
| | - Pedro Ruiz-Fortes
- Department of Ophthalmology, Vithas Medimar International Hospital, 03016 Alicante, Spain; (P.R.-F.); (R.S.-N.); (A.A.-P.)
| | - Roberto Soto-Negro
- Department of Ophthalmology, Vithas Medimar International Hospital, 03016 Alicante, Spain; (P.R.-F.); (R.S.-N.); (A.A.-P.)
| | - Carlos J. Hernández-Rodríguez
- Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, 03690 Alicante, Spain; (E.M.-P.); (C.J.H.-R.); (A.M.-M.)
- Department of Ophthalmology, Vithas Medimar International Hospital, 03016 Alicante, Spain; (P.R.-F.); (R.S.-N.); (A.A.-P.)
| | - Ainhoa Molina-Martín
- Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, 03690 Alicante, Spain; (E.M.-P.); (C.J.H.-R.); (A.M.-M.)
| | - Alfonso Arias-Puente
- Department of Ophthalmology, Vithas Medimar International Hospital, 03016 Alicante, Spain; (P.R.-F.); (R.S.-N.); (A.A.-P.)
| | - David P. Piñero
- Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, 03690 Alicante, Spain; (E.M.-P.); (C.J.H.-R.); (A.M.-M.)
- Department of Ophthalmology, Vithas Medimar International Hospital, 03016 Alicante, Spain; (P.R.-F.); (R.S.-N.); (A.A.-P.)
- Correspondence: ; Tel.: +34-965-903400
| |
Collapse
|
26
|
Martino F, Castro‐Torres JJ, Casares‐López M, Ortiz‐Peregrina S, Ortiz C, Jiménez JR. Effect of interocular differences on binocular visual performance after inducing forward scattering. Ophthalmic Physiol Opt 2022; 42:730-743. [PMID: 35499140 PMCID: PMC9321610 DOI: 10.1111/opo.12992] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Revised: 04/01/2022] [Accepted: 04/04/2022] [Indexed: 12/19/2022]
Abstract
Purpose To assess binocular visual performance by means of binocular summation on visual function after inducing monocular forward scattering, and to study the influence of interocular differences on ocular parameters. Methods Seven young healthy subjects were recruited. Four Bangerter foils and five fog filters were used to induce monocular forward scattering. To analyse the impact of the scatter, visual acuity, contrast sensitivity, visual discrimination capacity and distance stereoacuity were measured binocularly with the filter placed over the dominant eye. Additionally, interocular differences were calculated for four ocular parameters: the Objective Scatter Index (OSI), Strehl ratio (SR), modulation transfer function cut‐off (MTF cut off) and straylight (log[s]). Binocular summation was determined for these visual functions. Results A statistically significant deterioration in visual acuity, contrast sensitivity and stereoacuity was seen for all of the filter conditions with respect to the natural state (baseline), with the largest change being recorded for the Bangerter foils. Similarly, the interocular difference for the three retinal image quality parameters (OSI, SR and MTF cut‐off) and log(s) increased significantly for the Bangerter foil condition, but not for the fog filters (except log(s)). Binocular summation declined gradually with the Bangerter foils, but not for the fog filters. Statistically significant correlations were found, that is, the greater the interocular differences, the lower the binocular summation of the visual functions and the greater the distance stereoacuity. Conclusion Increased forward scattering in the dominant eye resulted in interocular differences, which reduced the overall binocular visual performance, including the binocular summation of several visual functions and distance stereoacuity. The results suggest that marked interocular differences in ocular parameters should be avoided in cases of ocular pathology, amblyopia and emmetropisation procedures (such as refractive surgery) or a monovision correction for presbyopia.
Collapse
Affiliation(s)
- Francesco Martino
- Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics University of Granada Granada Spain
| | - José J. Castro‐Torres
- Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics University of Granada Granada Spain
| | - Miriam Casares‐López
- Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics University of Granada Granada Spain
| | - Sonia Ortiz‐Peregrina
- Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics University of Granada Granada Spain
| | - Carolina Ortiz
- Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics University of Granada Granada Spain
| | - José R. Jiménez
- Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics University of Granada Granada Spain
| |
Collapse
|
27
|
Ortiz-Peregrina S, Ortiz C, Martino F, Casares-López M, Castro-Torres JJ, Anera RG. Speed management across road environments of varying complexities and self-regulation behaviors in drivers with cataract. Sci Rep 2022; 12:6951. [PMID: 35484276 PMCID: PMC9051061 DOI: 10.1038/s41598-022-10952-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Accepted: 04/15/2022] [Indexed: 11/08/2022] Open
Abstract
Evidence suggests that drivers with cataract self-regulate their driving, but there is a lack of objective information. This study compared speed behavior in older drivers with and without cataract and how the parameter is influenced by road traffic complexity and driver characteristics. The study included 15 drivers with cataract and a control group of 20 drivers. Visual status was assessed using visual acuity, contrast sensitivity, and intraocular straylight. Speed management was studied using a driving simulator. Driving difficulty and self-regulation patterns were evaluated by means of the Driver Habits Questionnaire (DHQ). The cataract group showed a significant decrease in visual function in all the parameters evaluated (p < 0.05). These drivers tended to drive at lower speeds than the control group. Road characteristics, gender, and intraocular straylight in the better eye were identified as significant predictors of speed management. Drivers with cataract experience greater driving difficulty, particularly when driving at night (p < 0.05). Drivers with cataract reduce their driving speed more than older drivers without visual impairment. The straylight parameter may be a good indicator of each driver's subjective perception of their own visual ability to drive. This work helps shed light on the mechanisms through which age-related visual impairment influences driving behavior.
Collapse
Affiliation(s)
- Sonia Ortiz-Peregrina
- Department of Optics, Laboratory of Vision Sciences and Applications, University of Granada, Edificio Mecenas, Av. Fuentenueva s/n, 18071, Granada, Spain.
| | - Carolina Ortiz
- Department of Optics, Laboratory of Vision Sciences and Applications, University of Granada, Edificio Mecenas, Av. Fuentenueva s/n, 18071, Granada, Spain.
| | - Francesco Martino
- Department of Optics, Laboratory of Vision Sciences and Applications, University of Granada, Edificio Mecenas, Av. Fuentenueva s/n, 18071, Granada, Spain
| | - Miriam Casares-López
- Department of Optics, Laboratory of Vision Sciences and Applications, University of Granada, Edificio Mecenas, Av. Fuentenueva s/n, 18071, Granada, Spain
| | - José J Castro-Torres
- Department of Optics, Laboratory of Vision Sciences and Applications, University of Granada, Edificio Mecenas, Av. Fuentenueva s/n, 18071, Granada, Spain
| | - Rosario G Anera
- Department of Optics, Laboratory of Vision Sciences and Applications, University of Granada, Edificio Mecenas, Av. Fuentenueva s/n, 18071, Granada, Spain
| |
Collapse
|
28
|
Zhang XF, Li XX, Xin C, Kline B, Kang MT, Li M, Qiao LY, Wang NL. Refractive Lens Exchange Surgery in Early-Onset High Myopia Patients With Partial Cataract. Front Med (Lausanne) 2022; 9:739197. [PMID: 35492336 PMCID: PMC9051036 DOI: 10.3389/fmed.2022.739197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Accepted: 03/08/2022] [Indexed: 12/04/2022] Open
Abstract
Purpose By reporting clinical characteristics and retinal image quality before and after refractive lens replacement surgery in early-onset high myopia (eoHM) patients presenting with partial cataract, we emphasized the need for an objective way to grade the severity of partial cataracts. Methods This retrospective, consecutive case series included six Chinese patients (nine eyes). Analysis of previous medical records, visual acuity, optometry, retinal image quality, and axial length (AXL) before surgery and after surgery was performed. Results Five females and one male (nine eyes) with a mean (± SD) age of 11.6 ± 7.9 years (range: 4–25 years) were included in this study. The preoperative spherical power ranged from −7.5 to −42 D. The mean follow-up time was 36 months (range: 24–48 months). Phacoemulsification was followed by in-the-bag implantation of intraocular lens. For patients who were under 6 years old, posterior capsulotomy + anterior vitrectomy were performed simultaneously. All surgeries were uneventful and no postoperative complications occurred during the entire follow-up period. All patients’ uncorrected visual acuity improved by ≥2 lines postoperatively(Snellen acuity). LogMAR best-corrected visual acuity was improved at 24-month (P = 0.042) and endpoint (P = 0.046) follow-ups. Modulation transfer function cutoff frequency (MTFcutoff) and objective scatter index (OSI) was significantly improved at 12-month (P = 0.025, P = 0.038), 24-month (P = 0.005, P = 0.007) and endpoint (P = 0.005, P = 0.008) follow-ups. Postoperative AXL remained stable during 2–4 year follow-ups (P > 0.05). Conclusion Refractive lens replacement surgery is safe and effective for improving functional vision in eoHM patients presenting with partial cataract. Retinal image quality could provide a useful and objective way to facilitate partial cataract severity evaluation and surgery decision making.
Collapse
Affiliation(s)
- Xi-Fang Zhang
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China
| | - Xiao-Xia Li
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China
| | - Chen Xin
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China
| | - Brad Kline
- Department of Ophthalmology, University of California, San Francisco, San Francisco, CA, United States
| | - Meng-Tian Kang
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China
| | - Meng Li
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China
| | - Li-Ya Qiao
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China
- *Correspondence: Li-Ya Qiao,
| | - Ning-Li Wang
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China
| |
Collapse
|
29
|
Panezai S, Jiménez-Villar A, Paniagua Diaz AM, Arias A, Gondek G, Manzanera S, Artal P, Grulkowski I. Intraocular scatter compensation with spatial light amplitude modulation for improved vision in simulated cataractous eyes. BIOMEDICAL OPTICS EXPRESS 2022; 13:2174-2185. [PMID: 35519252 PMCID: PMC9045940 DOI: 10.1364/boe.451878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 03/07/2022] [Accepted: 03/08/2022] [Indexed: 06/14/2023]
Abstract
Cataract is one of the common causes of visual impairment due to opacification of the crystalline lens. Increased intraocular scattering affects the vision of cataract patients by reducing the quality of the retinal image. In this study, an amplitude modulation-based scatter compensation (AM-SC) method is developed to minimize the impact of straylight on the retinal image. The performance of the AM-SC method was quantified by numerical simulations of point spread function and retinal images in the presence of different amounts of straylight. The approach was also experimentally realized in a single-pass system with a digital micro-mirror device used as a spatial amplitude modulator. We showed that the AM-SC method allows to enhance contrast sensitivity in the human eyes in vivo with induced scattering.
Collapse
Affiliation(s)
- Spozmai Panezai
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, ul. Grudziądzka 5, 87-100 Toruń, Poland
| | - Alfonso Jiménez-Villar
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, ul. Grudziądzka 5, 87-100 Toruń, Poland
| | - Alba M. Paniagua Diaz
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), E-30100 Murcia, Spain
| | - Augusto Arias
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), E-30100 Murcia, Spain
| | - Grzegorz Gondek
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, ul. Grudziądzka 5, 87-100 Toruń, Poland
| | - Silvestre Manzanera
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), E-30100 Murcia, Spain
| | - Pablo Artal
- Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo (Edificio 34), E-30100 Murcia, Spain
| | - Ireneusz Grulkowski
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, ul. Grudziądzka 5, 87-100 Toruń, Poland
| |
Collapse
|
30
|
Ávila FJ, Casado P. Optical instrument for the study of time recovery from total disability glare vision. APPLIED OPTICS 2022; 61:2438-2443. [PMID: 35333264 DOI: 10.1364/ao.453842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Accepted: 02/23/2022] [Indexed: 06/14/2023]
Abstract
Disability glare is defined as the loss of contrast sensitivity of the retinal image due to intraocular straylight originated from the presence of an intense and broad bright light in the field of vision. This loss of vision can range between vision loss at high spatial frequencies or total temporal blindness. If the extreme case occurs, the recovery time is crucial in night driving conditions or those professional activities in which maximum visual acuity is required at any moment. The recovery time depends mainly on the intensity and glare angle of the light source, ocular straylight, and the photoreceptor response at the retina. The recovery time can also be affected by ocular pathologies, aging, or physiological factors that increase ocular straylight. The aim of this work is to develop a new optical instrument based on psychophysical methodology as well as to investigate the recovery time from total disability glare (photobleaching) as a function of the contrast of the visual target and the glare angle of the source in healthy volunteers. Results showed significant exponential correlation between recovery time and contrast of the visual target and linear correlation between contrast sensitivity and the glare angle. Those findings allowed to obtain an empirical expression to compute the recovery time required to restore contrast sensitivity baseline vision after photobleaching. Finally, a statistical dependence of recovery time with age was found for short glare angles that disappear as the glare angle increases.
Collapse
|
31
|
Marta A, Marques JH, Almeida D, José D, Barbosa I. Keratoconus and Visual Performance with Different Contact Lenses. Clin Ophthalmol 2021; 15:4697-4705. [PMID: 34949911 PMCID: PMC8689658 DOI: 10.2147/opth.s345154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 11/25/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose To analyze the visual performance in contact lens wearers with keratoconus. Methods A retrospective study including contact lens (CL) wearers was performed. The current best-corrected visual acuity with contact lens (BCVA-CL) and with spectacles (BCVA-S) correction, contrast sensitivity (CS) (by Metrovision-MonPack3®), analysis of light scattering in the retina and vision break-up time (HD Analyzer®), and corneal tomography (Oculus Pentacam® HR) were evaluated. Results This study included 96 eyes of 59 patients with Keratoconus. Rigid gas permeable contact lenses (RGPCL), hybrid contact lenses (HCL), and silicone hydrogel/hydrogel contact lenses (HGCL) were fitted in 67, 17, and 12 eyes, respectively. Dynamic objective scatter index (OSI) (p = 0.024), minimum OSI (p = 0.037) and maximum OSI (p = 0.040) were significantly better with RGPCL and worse with HGCL. Mean CS in photopic conditions was significantly worse with HGCL and better with HCL (p = 0.006), without differences in mesopic conditions (p = 0.121). RGPCL wearers showed a higher mean K (p = 0.020), and a lower corneal thickness at the thinnest point (p=0.011). Conclusion Visual quality varied significantly with different types of CL. Although RGPCL was fitted in patients with worse Pentacam tomographic parameters, RGPCL was associated with a better dynamic visual quality.
Collapse
Affiliation(s)
- Ana Marta
- Department of Ophthalmology, Centro Hospitalar Universitário do Porto (CHUPorto), Oporto, Portugal.,Instituto de Ciências Biomédicas Abel Salazar (ICBAS), Oporto, Portugal
| | - João Heitor Marques
- Department of Ophthalmology, Centro Hospitalar Universitário do Porto (CHUPorto), Oporto, Portugal
| | - Daniel Almeida
- Department of Ophthalmology, Centro Hospitalar Universitário do Porto (CHUPorto), Oporto, Portugal
| | - Diana José
- Department of Ophthalmology, Centro Hospitalar Universitário do Porto (CHUPorto), Oporto, Portugal
| | - Irene Barbosa
- Department of Ophthalmology, Centro Hospitalar Universitário do Porto (CHUPorto), Oporto, Portugal.,Instituto de Ciências Biomédicas Abel Salazar (ICBAS), Oporto, Portugal
| |
Collapse
|
32
|
Sánchez RF, García-Guerra CE, Martínez-Roda JA, de Paul AG, Issolio LA, Pujol J. Implementation of the Frequency Scatter Index in Clinical Commercially Available Double-pass Systems. Curr Eye Res 2021; 47:391-398. [PMID: 34738850 DOI: 10.1080/02713683.2021.2002908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
A previous work has reported a methodology to quantify intraocular scattering using a high sensitivity double-pass instrument with a robust index, the frequency scatter index. The purpose of our study was to evaluate an adaptation of the frequency scatter index for use in clinical double-pass systems. A prospective observational study was carried out in a group of patients with nuclear cataracts (n = 52) and in a control group (n = 11) using conventional double-pass systems. The frequency scatter index and the objective scatter index were used to assess the scattering. The Spearman coefficient was calculated to assess the correlation between both indexes, obtained from the double-pass images. Simultaneous measurements were performed with a double-pass and with a Hartmann-Shack wavefront sensor in the control group. The root-mean-square wavefront error and the full width at half maximum of the double-pass image were used to quantify the residual aberrations introduced by the variations in pupil size and retinal eccentricity. Measurement in eyes with different grades of cataracts shows a strong correlation (ρ = 0.929, p < .0001) between the frequency scatter index and the objective scatter index. A certain degree of correlation was observed between the objective scatter index and the root-mean-square and between the objective scatter index and the full width at half maximum, both for measurements with a different pupillary diameter and with a different retinal eccentricity (p < .05). No relationship was observed between the frequency scatter index and the root-mean-square or between the frequency scatter index and the full width at half maximum (p > .05). We have introduced and evaluated an adaptation of a methodology proposed recently for the measurement of intraocular scattering using the double-pass technique with a robust index, which is less affected by ocular aberrations. The frequency scatter index can be applied to conventional double-pass instruments available in clinical environments.
Collapse
Affiliation(s)
- Roberto F Sánchez
- Instituto de Investigación en Luz, Ambiente y Visión, CONICET-UNT, Tucumán, Argentina
| | - Carlos E García-Guerra
- Centre de Desenvolupament de Sensors, Instrumentació i Sistemes, Universitat Politecnica de Catalunya, Barcelona, España
| | - Joan A Martínez-Roda
- Centre de Desenvolupament de Sensors, Instrumentació i Sistemes, Universitat Politecnica de Catalunya, Barcelona, España
| | - Aníbal G de Paul
- Instituto de Investigación en Luz, Ambiente y Visión, CONICET-UNT, Tucumán, Argentina
| | - Luis A Issolio
- Instituto de Investigación en Luz, Ambiente y Visión, CONICET-UNT, Tucumán, Argentina.,Departamento de Luminotecnia, Luz y Visión, Universidad Nacional de Tucumán, Tucumán, Argentina
| | - Jaume Pujol
- Centre de Desenvolupament de Sensors, Instrumentació i Sistemes, Universitat Politecnica de Catalunya, Barcelona, España
| |
Collapse
|
33
|
Li B, Liu Y, Hu Y, Shi M. Comparison of the IOLMaster 700 and the Pentacam in the Analysis of the Lens Nuclear Density Before the Cataract Surgery. Front Med (Lausanne) 2021; 8:691173. [PMID: 34746167 PMCID: PMC8563836 DOI: 10.3389/fmed.2021.691173] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Accepted: 09/20/2021] [Indexed: 12/19/2022] Open
Abstract
Purpose: To evaluate the difference of the lens nuclear density measured before and after mydriasis by using the IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany) and the Pentacam Scheimpflug imaging (Pentacam HR, Oculus Incorporation, Wetzlar, Germany) and investigate the relationship between the measurement data and the phacoemulsification parameters. Methods: Patients with age-related nuclear cataracts diagnosed on the slit-lamp examination were enrolled in the age range of 53–76 years. No patient had a history of ocular surgery, laser treatment, or general disorders affecting vision. The mean optical density (OD) was measured by the IOLMaster 700 by using the Image-Pro® Plus software before and after mydriasis. The Pentacam nucleus densitometry (PND) was obtained automatically from the Pentacam Scheimpflug imaging and compared with OD. The correlation between OD and effective phacoemulsification time (EPT), PND, and EPT were analyzed, respectively. Results: In this study, 53 eyes of 52 patients were evaluated. Before and after mydriasis, the mean OD values were 64.34 ± 23.31 and 63.81 ± 23.21 pixel units, respectively; the mean PND values were 28.51 ± 11.42 and 25.41 ± 11.31, respectively; and the mean EPT value was 6.24 ± 3.49. The Bland–Altman analysis showed that the lens nuclear densities of the two devices were highly consistent. There was no significant difference in the OD values (t = 0.455, p > 0.05) before and after mydriasis, but the difference has existed in the PND values (t = 2.509, p < 0.05). The OD and PND values were positively correlated with EPT before and after mydriasis (rOD−Before = 0.604, rOD−After = 0.593, rPND−Before = 0.701, and rPND−After = 0.891, p < 0.01). Conclusion: The combination of the IOLMaster 700 and the Image-Pro® Plus software can quantitatively evaluate the degree of the cataract lens opacification. It has good consistency with the Pentacam and is positively correlated with the phacoemulsification parameters. It is expected to become a new method to predict the phacoemulsification parameters before and during cataract surgery.
Collapse
Affiliation(s)
- Bowen Li
- The Department of Ophthalmology, The Fourth People's Hospital of Shenyang, Shenyang, China
| | - Yuqi Liu
- The Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, Shenyang, China.,The Department of Ophthalmology, China Medical University, Shenyang, China
| | - Yiping Hu
- The Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, Shenyang, China.,The Department of Ophthalmology, China Medical University, Shenyang, China
| | - Mingyu Shi
- The Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, Shenyang, China.,The Department of Ophthalmology, China Medical University, Shenyang, China
| |
Collapse
|
34
|
Jeon YJ, Yoon Y, Kim TI, Koh K. Comparison Between an Intraocular Lens With Extended Depth of Focus (Tecnis Symfony ZXR00) and a New Monofocal Intraocular Lens With Enhanced Intermediate Vision (Tecnis Eyhance ICB00). Asia Pac J Ophthalmol (Phila) 2021; 10:542-547. [PMID: 34608065 PMCID: PMC8673848 DOI: 10.1097/apo.0000000000000439] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 08/24/2021] [Indexed: 11/26/2022] Open
Abstract
PURPOSE This study compared the extended depth of focus (EDOF) intraocular lens (IOL) (ZXR00; Tecnis Symfony, Johnson & Johnson Vision, Santa Ana, CA, US) to a novel, higher-order aspheric monofocal IOL (ICB00; Tecnis Eyhance, Johnson & Johnson Vision, Santa Ana, CA, US) which uses the same platform and material. METHODS Medical records of patients undergoing cataract surgery with ZXR00 or ICB00 implantation between March 2020 and January 2021 and with the data available for the 3-month visit were reviewed. The uncorrected near, intermediate, and distance visual acuity (VA); corrected distance VA; and optical quality parameters were the main outcome measures. RESULTS Among the 174 enrolled patients, 72 and 102 received the ZXR00 and ICB00, respectively. The average patient ages were 59.6 ± 10.6 (range: 49 to 70) and 65.2 ± 8.2 (range: 45 to 82) years in the ZXR00 and ICB00 groups, respectively, with significantly older patients in the ICB00 group. The other baseline parameters were not different for the 2 groups. Compared to the ICB00 group, the ZXR00 group showed markedly superior near VA (P < 0.05) at 3 months postoperatively. In terms of optical quality, ICB00 was, statistically, significantly superior to ZXR00. CONCLUSIONS The ZXR00 showed remarkable near vision and defocus curve smoothness, while the ICB00 achieved better optical quality. The 2 IOLs had comparable distance and intermediate vision.
Collapse
Affiliation(s)
- Young Joon Jeon
- Department of Opthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Republic of Korea
| | - Yisang Yoon
- Department of Opthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Republic of Korea
| | - Tae-im Kim
- Department of Opthalmology, Severance Eye Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Kyungmin Koh
- Department of Opthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
35
|
Bettach E, Zadok D, Abulafia A, Shoshani A, Ghebali RA, Weill Y, Smadja D. Influence of Reading on Smartphone Screens on Visual Optical Quality Metrics and Tear Film Stability. Cornea 2021; 40:1309-1315. [PMID: 33470679 DOI: 10.1097/ico.0000000000002656] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Accepted: 11/25/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate the impact of a prolonged reading session on a smartphone screen on optical quality metrics and tear film stability. METHODS This prospective study was conducted in 41 healthy volunteers who were asked to read an article on a smartphone screen for 20 minutes. The following tests were performed before the reading task in this consecutive order and repeated after the reading task in the same order: automated noninvasive tear break-up time, optical quality assessment including Objective Scatter Index (OSI), modulation transfer function, Strehl ratio, and tear film dynamic analysis as follows: vision break-up time (VBUT) as a function of OSI changes within 20 seconds, using a double-pass aberrometer imaging system, and fluorescein tear break-up time (FBUT) measured using the slit lamp. RESULTS All break-up time-related parameters (noninvasive tear break-up time, FBUT and VBUT) were significantly reduced after the reading task (P < 0.01). The OSI was significantly worsened after the reading task (P = 0.01), whereas all the other optical quality metrics (modulation transfer function and Strehl ratio) slightly deteriorated, were not statistically significant. A significant correlation was found between the shortening of the FBUT, VBUT, and the worsening of the OSI (r = -0.33, P < 0.05). CONCLUSIONS A reading session on a smartphone screen in healthy subjects was found to significantly affect the tear film stability and objectively worsen the retinal image quality.
Collapse
Affiliation(s)
- Emmanuel Bettach
- Department of Ophthalmology, Shaare Zedek Medical Center, Jerusalem, Israel; Affiliated with the Hebrew University of Jerusalem; and
- iSEARCH, Innovation Shaarezedek Eye Advanced Research Center Hub, Jerusalem, Israel
| | - David Zadok
- Department of Ophthalmology, Shaare Zedek Medical Center, Jerusalem, Israel; Affiliated with the Hebrew University of Jerusalem; and
- iSEARCH, Innovation Shaarezedek Eye Advanced Research Center Hub, Jerusalem, Israel
| | - Adi Abulafia
- Department of Ophthalmology, Shaare Zedek Medical Center, Jerusalem, Israel; Affiliated with the Hebrew University of Jerusalem; and
- iSEARCH, Innovation Shaarezedek Eye Advanced Research Center Hub, Jerusalem, Israel
| | - Avi Shoshani
- Department of Ophthalmology, Shaare Zedek Medical Center, Jerusalem, Israel; Affiliated with the Hebrew University of Jerusalem; and
- iSEARCH, Innovation Shaarezedek Eye Advanced Research Center Hub, Jerusalem, Israel
| | - Rony A Ghebali
- iSEARCH, Innovation Shaarezedek Eye Advanced Research Center Hub, Jerusalem, Israel
| | - Yishay Weill
- Department of Ophthalmology, Shaare Zedek Medical Center, Jerusalem, Israel; Affiliated with the Hebrew University of Jerusalem; and
- iSEARCH, Innovation Shaarezedek Eye Advanced Research Center Hub, Jerusalem, Israel
| | - David Smadja
- Department of Ophthalmology, Shaare Zedek Medical Center, Jerusalem, Israel; Affiliated with the Hebrew University of Jerusalem; and
- iSEARCH, Innovation Shaarezedek Eye Advanced Research Center Hub, Jerusalem, Israel
| |
Collapse
|
36
|
Haddad JS, Rocha KM, Waring GO, Faria-Correia F, Ambrosio R. Dysfunctional lens syndrome: a prospective review. REVISTA BRASILEIRA DE OFTALMOLOGIA 2021. [DOI: 10.37039/1982.8551.20210037] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
|
37
|
Tabernero J, Garcia-Porta N, Artal P, Pardhan S. Intraocular Scattering, Blinking Rate, and Tear Film Osmolarity After Exposure to Environmental Stress. Transl Vis Sci Technol 2021; 10:12. [PMID: 34379094 PMCID: PMC8362624 DOI: 10.1167/tvst.10.9.12] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose Dry environments, such as those in offices or aircraft cabins, can potentially generate ocular discomfort and alter the tear film. We compare light scatter, blinking rate, and tear osmolarity in young and older subjects after exposure to low humidity using a controlled environmental chamber. Methods Two groups of healthy subjects were recruited; younger (N = 13, 27 ± 6 years) and older (N = 23, 71 ± 7 years). Measurements were carried out before and after 90-minute exposure to low relative humidity (5%) and constant temperature (23 degrees). Ocular light scatter was measured using a double-pass instrument (OQAS, Visiometrics, Spain). Blinking rate was monitored using an infrared video camera. Tear osmolarity was measured using the TearLab system (Escondido, CA, USA). Results Ocular light scatter increased by a factor of 10% after exposure to low humidity in the older group (P = 0.03) but did not change significantly in the younger group. Blinking rate increased significantly (40% more blinks) in both groups but there was no difference between the groups. No significant differences in osmolarity were shown between two age groups or as result of environmental stress. Conclusions Exposure to dry environment increased light scatter in older subjects. Although more blinks were triggered in both younger and older groups to prevent corneal dehydration, there was no difference between the groups. Blink rate and osmolarity are not associated with the difference in light scatter. Translational Relevance Our work approaches a clinical care problem using basic research methods (measuring ocular scatter and blink ratio).
Collapse
Affiliation(s)
- Juan Tabernero
- Vision and Eye Research Institute, Anglia Ruskin University, Cambridge, UK.,Departamento de Electromagnetismo y Electrónica, Universidad de Murcia, Spain
| | - Nery Garcia-Porta
- Vision and Eye Research Institute, Anglia Ruskin University, Cambridge, UK.,Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, UK
| | - Pablo Artal
- Laboratorio de Óptica, Universidad de Murcia, Murcia, Spain
| | - Shahina Pardhan
- Vision and Eye Research Institute, Anglia Ruskin University, Cambridge, UK
| |
Collapse
|
38
|
Association of optical cataract indices with cataract severity and visual function. Int Ophthalmol 2021; 42:27-33. [PMID: 34378173 DOI: 10.1007/s10792-021-01995-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Accepted: 07/30/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE The purpose of this study is to determine the correlation between subjective and optical measurements used during cataract evaluation, including the iTrace Dysfunctional Lens Index (DLI), the HD Analyzer Objective Scatter Index (OSI), Lens Opacities Classification System III (LOCS III), Visual Function-14 Questionnaire (VF-14), and the Pelli-Robson Contrast Sensitivity Chart (PRCSC). METHODS Seventy eyes from 70 patients were enrolled, including all stages of age-related nuclear cataracts. The LOCS III-NO with a cutoff of 3.2 was chosen to divide the population into two groups. Eyes with corneal or retinal pathology were excluded. All patients were evaluated with the iTrace's DLI, HD Analyzer's OSI, LOCS III, VF-14, and the PRCSC during each follow-up visit. Correlation analyses were performed using Stata software, version 14.0, StataCorp. RESULTS The LOCS III-NO, DLI, OSI, and VF-14 questionnaire each correlated moderately with the BCVA with a Spearman rho value of 0.37, - 0.45, 0.40, and - 0.35, respectively. The DLI correlated moderately with LOCS III-NO with a rho value of - 0.37 and with the VF-14 questionnaire with a rho value of 0.35. The OSI correlated with both the contrast sensitivity and DLI with a rho value of - 0.35 and - 0.55, respectively. CONCLUSIONS The DLI correlated with cataract symptoms (measured by the VF-14 questionnaire) in addition to BCVA. The OSI correlated moderately with contrast sensitivity and BCVA. The highest correlation was between DLI and OSI.
Collapse
|
39
|
Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study. BMC Ophthalmol 2021; 21:292. [PMID: 34340669 PMCID: PMC8330115 DOI: 10.1186/s12886-021-02048-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Accepted: 07/09/2021] [Indexed: 01/02/2023] Open
Abstract
BACKGROUND To compare the correction effect and optical quality after small-incision lenticule extraction (SMILE) and femtosecond laser assisted laser in situ keratomileusis (FS-LASIK) for high myopia. METHODS 51 high myopia eyes after SMILE and 49 high myopia eyes after FS-LASIK were enrolled and divided into two groups retrospectively. The OQAS and iTrace analyzer were used for optical quality inspection. Between the two groups the spherical equivalent (SE), astigmatism, uncorrected distant visual acuity (UDVA), strehl ratio (SR), modulation transfer function cutoff frequency (MTF cutoff), objective scatter index (OSI) and wavefront aberrations were analyzed and compared before surgery and at 1, 6 and 12 months after surgery. RESULTS After the operation: (1) SE and astigmatism declined and UDVA increased significantly in both groups, and UDVA was better after SMILE than FS-LASIK. (2) SR and MTF cutoff reduced and OSI increased significantly after SMILE and FS-LASIK. SR and MTF cutoff were significantly higher after SMILE than FS-LASIK. OSI was significantly lower after SMILE than FS-LASIK. (3) The total wavefront aberration, total low-order wavefront aberration, defocus and astigmatism aberration as well as trefoil aberration reduced significantly in both groups. The total high-order wavefront aberration increased significantly after FS-LASIK. The spherical and coma aberration increased significantly in both groups. The total high-order wavefront aberration and coma aberration at 1 month were higher after FS-LASIK than SMILE. CONCLUSION The optical quality descended after SMILE and FS-LASIK. SMILE was superior to FS-LASIK at the correction effect and optical quality for high myopia. The combination of OQAS and iTrace analyzer is a valuable complementary measurement in evaluating the optical quality after the refractive surgery. TRIAL REGISTRATION This is a retrospective study. This research was approved by the ethics committee of Xiangya Hospital and the IRB approval number is 201612074.
Collapse
|
40
|
Casares-López M, Castro-Torres JJ, Ortiz-Peregrina S, Martino F, Ortiz C. Changes in Visual Performance under the Effects of Moderate-High Alcohol Consumption: The Influence of Biological Sex. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:6790. [PMID: 34202674 PMCID: PMC8297204 DOI: 10.3390/ijerph18136790] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 06/21/2021] [Accepted: 06/23/2021] [Indexed: 01/14/2023]
Abstract
The purpose of this study was to analyze the changes in visual functions under the effects of moderate-high breath alcohol concentrations (BrACs), and the influence of biological sex on visual deterioration, considering different factors. A total of 37 healthy habitual alcohol users were enrolled in the experiment. The participants underwent a baseline session and a second session after an intake of 450 mL of red wine, so that all of them reached a BrAC above 0.25 mg/L. Visual performance was assessed by measuring the contrast sensitivity function, the halo perception, the stereopsis, and finally the retinal image quality. A Visual Deterioration Score (VDS) was calculated using the deterioration of these visual variables. All visual functions analyzed were significantly impaired following alcohol consumption (p < 0.05). The VDS was associated with the BrAC (ρ = -0.476). The VDS was also significantly higher in females, with the BrAC having a significant effect on the variability of the VDS in males and females (p < 0.05). However, the body mass index showed no significant effect (p > 0.05). Visual functions were significantly impaired under the influence of alcohol, and this deterioration was greater in females. The deterioration depends on the BrAC reached, being the primary thing responsible for the differences observed between males and females.
Collapse
Affiliation(s)
- Miriam Casares-López
- Laboratory of Vision Sciences and Applications, Department of Optics, Facultad de Ciencias (Edificio Mecenas), University of Granada, Avenida Fuentenueva s/n, 18071 Granada, Spain; (S.O.-P.); (F.M.); (C.O.)
| | - José J. Castro-Torres
- Laboratory of Vision Sciences and Applications, Department of Optics, Facultad de Ciencias (Edificio Mecenas), University of Granada, Avenida Fuentenueva s/n, 18071 Granada, Spain; (S.O.-P.); (F.M.); (C.O.)
| | | | | | | |
Collapse
|
41
|
Castro-Torres JJ, Martino F, Casares-López M, Ortiz-Peregrina S, Ortiz C. Visual performance after the deterioration of retinal image quality: induced forward scattering using Bangerter foils and fog filters. BIOMEDICAL OPTICS EXPRESS 2021; 12:2902-2918. [PMID: 34123509 PMCID: PMC8176796 DOI: 10.1364/boe.424715] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 04/15/2021] [Accepted: 04/19/2021] [Indexed: 05/09/2023]
Abstract
We induced and evaluated different levels of retinal-image degradation using Bangerter foils and fog filters. We found increased straylight and an important deterioration in visual performance, assessed by means of visual acuity, contrast threshold, and visual discrimination capacity. Bangerter foils induced forward scattering levels comparable to those observed in mature to severe cataracts, with an important impact of halos and starbursts. Fog filters induced lower levels of intraocular scattering, although luminous veils and circular halos were reported. The visual disturbance index positively correlated with intraocular scattering and straylight. Our results show retinal-image quality has an important influence on night-vision performance.
Collapse
|
42
|
Amorim-de-Sousa A, Macedo-de-Araújo R, Fernandes P, Queirós A, González-Méijome JM. Multifocal Electroretinogram in Keratoconus Patients without and with Scleral Lenses. Curr Eye Res 2021; 46:1732-1741. [PMID: 33823736 DOI: 10.1080/02713683.2021.1912781] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Purpose: To investigate changes in the multifocal electroretinogram (mfERG) response in eyes with keratoconus when corrected with scleral lenses (SL) compared with the best correction in glasses.Methods: The mfERG responses in 10 eyes with keratoconus were recorded with the best correction using both a trial frame (baseline) and a hexafocon A SL using an electrophysiological diagnostic system. Electrophysiologic measurements were performed with the pupils fully dilated with instillation of 1% phenylephrine. The implicit time (milliseconds), amplitude (nV), and response density (nV/deg2) of the peaks (N1, P1, and N2) were analyzed for the total mfERG response, six rings and four quadrants of the retina, and compared between the two conditions.Results: All eyes had a significant improvement in visual quality with the SL compared with baseline (mean differences, 0.26 ± 0.17 and 0.22 ± 0.13 logarithm of the minimum angle of resolution for high- and low-contrast visual acuity, respectively). The peaks implicit times of the mfERG responses did not show significant differences (p > .05). The P1 amplitude decreased in all the retinal areas with the SL. Only the total retinal response and the nasal quadrants reached significance (p ≤ 0.044). The P1 response density in ring 1 was on average higher with the SL, but not significantly so. The decline in P1 response density from the center to the periphery was more abrupt with the SL, and was more similar to the response density distribution of a typical subject, without a corneal pathology.Conclusions: mfERG did not show any change associated with retinal disease in young patients with keratoconus. Although the improved visual performance was not associated with changes in the mfERG response, the correction of irregular astigmatism with the SL helps exclude the optical effect induced by keratoconus.
Collapse
Affiliation(s)
- Ana Amorim-de-Sousa
- Clinical & Experimental Optometry Research Lab (CEORLab), Center of Physics, University of Minho, Braga, Portugal
| | - Rute Macedo-de-Araújo
- Clinical & Experimental Optometry Research Lab (CEORLab), Center of Physics, University of Minho, Braga, Portugal
| | - Paulo Fernandes
- Clinical & Experimental Optometry Research Lab (CEORLab), Center of Physics, University of Minho, Braga, Portugal
| | - António Queirós
- Clinical & Experimental Optometry Research Lab (CEORLab), Center of Physics, University of Minho, Braga, Portugal
| | - José M González-Méijome
- Clinical & Experimental Optometry Research Lab (CEORLab), Center of Physics, University of Minho, Braga, Portugal
| |
Collapse
|
43
|
Marcos S, Martinez-Enriquez E, Vinas M, de Castro A, Dorronsoro C, Bang SP, Yoon G, Artal P. Simulating Outcomes of Cataract Surgery: Important Advances in Ophthalmology. Annu Rev Biomed Eng 2021; 23:277-306. [PMID: 33848431 DOI: 10.1146/annurev-bioeng-082420-035827] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
As the human eye ages, the crystalline lens stiffens (presbyopia) and opacifies (cataract), requiring its replacement with an artificial lens [intraocular lens (IOL)]. Cataract surgery is the most frequently performed surgical procedure in the world. The increase in IOL designs has not been paralleled in practice by a sophistication in IOL selection methods, which rely on limited anatomical measurements of the eye and the surgeon's interpretation of the patient's needs and expectations. We propose that the future of IOL selection will be guided by 3D quantitative imaging of the crystalline lens to map lens opacities, anticipate IOL position, and develop fully customized eye models for ray-tracing-based IOL selection. Conversely, visual simulators (in which IOL designs are programmed in active elements) allow patients to experience prospective vision before surgery and to make more informed decisions about which IOL to choose. Quantitative imaging and optical and visual simulations of postsurgery outcomes will allow optimal treatments to be selected for a patient undergoing modern cataract surgery.
Collapse
Affiliation(s)
- Susana Marcos
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain;
| | - Eduardo Martinez-Enriquez
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain;
| | - Maria Vinas
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain;
| | - Alberto de Castro
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain;
| | - Carlos Dorronsoro
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid 28006, Spain; .,2EyesVision, Madrid 28760, Spain
| | - Seung Pil Bang
- Flaum Eye Institute, The Institute of Optics, Center for Visual Science, Department of Biomedical Engineering, University of Rochester, Rochester, New York 14632, USA
| | - Geunyoung Yoon
- Flaum Eye Institute, The Institute of Optics, Center for Visual Science, Department of Biomedical Engineering, University of Rochester, Rochester, New York 14632, USA
| | - Pablo Artal
- Laboratorio de Óptica, Universidad de Murcia, Murcia 30100, Spain
| |
Collapse
|
44
|
Kang KH, Song MY, Kim KY, Hwang KY, Kwon YA, Koh K. Visual Performance and Optical Quality after Implantation of a New Generation Monofocal Intraocular Lens. KOREAN JOURNAL OF OPHTHALMOLOGY 2021; 35:112-119. [PMID: 33845556 PMCID: PMC8046615 DOI: 10.3341/kjo.2020.1115] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Accepted: 02/21/2021] [Indexed: 11/26/2022] Open
Abstract
Purpose To evaluate the performance of two intraocular lenses (IOLs). The new monofocal IOL using a higher-order aspheric optic (Tecnis Eyhance ICB00) was compared to a standard monofocal IOL (Tecnis monofocal ZCB00) of the identical platform and material. Methods The medical records of the patients who had undergone cataract surgery with implantation of either the ZCB00 or the ICB00 in the dominant eye from March 2020 to August 2020 and with available data from the 3-month visit were reviewed. Subjects with ocular comorbidities or corneal astigmatism greater than 1.00 diopters were excluded. The uncorrected near, intermediate, distance visual acuity and corrected distance visual acuity were the main outcome measures. Optical quality parameters measured using an optical quality analysis system, clinical records including age, sex, laterality, ocular dominance, and information related to refractory errors was also collected. Parameters related to the refractory errors were all uniformly based on the Barrett Universal II formula. Results Of the 197 recruited patients, 111 and 86 were implanted with the ICB00 and ZCB00, respectively. No statistically significant differences in baseline parameters were observed between the two groups. While no statistically significant differences in distance visual acuity or optical quality were found between the two groups, compared to the ZCB00 group, the ICB00 group showed significantly higher intermediate visual acuity (p < 0.001) and near visual acuity (p < 0.05) 3 months postoperatively. Conclusions ICB00 provided superior intermediate vision and comparable distance performance and photic phenomena compared to a standard monofocal IOL.
Collapse
Affiliation(s)
- Kyoung Hae Kang
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Korea
| | - Mi Yeon Song
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Korea
| | - Kook Young Kim
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Korea
| | - Kyu-Yeon Hwang
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Korea
| | - Young-A Kwon
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Korea
| | - Kyungmin Koh
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Korea
| |
Collapse
|
45
|
Factors Influencing Contrast Sensitivity Function in Eyes with Mild Cataract. J Clin Med 2021; 10:jcm10071506. [PMID: 33916605 PMCID: PMC8038429 DOI: 10.3390/jcm10071506] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 03/17/2021] [Accepted: 03/26/2021] [Indexed: 01/13/2023] Open
Abstract
This study was aimed to evaluate the relationship between the area under the log contrast sensitivity function (AULCSF) and several optical factors in eyes suffering mild cataract. We enrolled 71 eyes of 71 patients (mean age, 71.4 ± 10.7 (standard deviation) years) with cataract formation who were under surgical consultation. We determined the area under the log contrast sensitivity function (AULCSF) using a contrast sensitivity unit (VCTS-6500, Vistech). We utilized single and multiple regression analyses to investigate the relevant factors in such eyes. The mean AULSCF was 1.06 ± 0.16 (0.62 to 1.38). Explanatory variables relevant to the AULCSF were, in order of influence, logMAR best spectacle-corrected visual acuity (BSCVA) (p < 0.001, partial regression coefficient B = −0.372), and log(s) (p = 0.023, B = −0.032) (adjusted R2 = 0.402). We found no significant association with other variables such as age, gender, uncorrected visual acuity, nuclear sclerosis grade, or ocular HOAs. Eyes with better BSCVA and lower log(s) are more susceptible to show higher AULCSF, even in mild cataract subjects. It is indicated that both visual acuity and intraocular forward scattering play a role in the CS function in such eyes.
Collapse
|
46
|
Ruminski D, Sebag J, Toledo RD, Jiménez-Villar A, Nowak JK, Manzanera S, Artal P, Grulkowski I. Volumetric Optical Imaging and Quantitative Analysis of Age-Related Changes in Anterior Human Vitreous. Invest Ophthalmol Vis Sci 2021; 62:31. [PMID: 33929483 PMCID: PMC8088225 DOI: 10.1167/iovs.62.4.31] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Purpose The purpose of this study was to characterize age-related changes in anterior human vitreous with 3-D swept source optical coherence tomography (SS-OCT) and evaluate associations with axial length (AL) and contrast sensitivity function (CSF). Methods There were 49 phakic eyes in 49 patients (40.0 ± 19.3 years) had 3-D volumetric scanning of the lens and retrolental vitreous with SS-OCT at 1050 nm. OCT-derived indices of vitreous optical density (VOD), vitreous opacification ratio (VOR), and lens optical density (LOD) were correlated with AL and double-pass assessment of retinal point spread function (Objective Scatter Index [OSI]). CSF was measured using an adaptive-optics visual simulator (area under log-log contrast sensitivity function [AULCSF]). Results Vitreous SS-OCT detected gel vitreous, liquefied lacunae, Berger's space, retrolental laminae, and fibrous opacifications. VOD, VOR, and LOD showed high reproducibility (intraclass correlation coefficients 0.968, 0.975, and 0.998, respectively). VOD was highly correlated with VOR (Pearson's R = 0.96, P < 0.000001). VOD, VOR, and LOD correlated with age (R = 0.48, 0.58, and 0.85, P < 0.001 for each). VOR and LOD correlated with OSI (R = 0.36, P = 0.0094, and R = 0.36, P = 0.0096, respectively). VOR correlated negatively with AULCSF (R = −0.53, P < 0.00009), which was related to OSI. Myopic eyes had higher OSI than nonmyopic eyes (P = 0.0121), consistent with correlation between OSI and AL (R = 0.37, P = 0.0091). Multivariable regression confirmed these findings. Conclusions SS-OCT visualized microstructural features of anterior human vitreous, where opacification is associated with increased light scattering and CSF degradation. SS-OCT enables high-resolution optical evaluation of vitreous opacities.
Collapse
Affiliation(s)
- Daniel Ruminski
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Torun, Poland
| | - J Sebag
- VMR Institute for Vitreous Macula Retina, Huntington Beach, California, United States
| | - Raúl Duarte Toledo
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain
| | - Alfonso Jiménez-Villar
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Torun, Poland
| | - Jan K Nowak
- Department of Pediatric Gastroenterology and Metabolic Diseases, Poznan University of Medical Sciences, Poznan, Poland
| | - Silvestre Manzanera
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain
| | - Pablo Artal
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain
| | - Ireneusz Grulkowski
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Torun, Poland
| |
Collapse
|
47
|
Functional Optical Zone and Visual Quality After Small-Incision Lenticule Extraction for High Myopic Astigmatism. Ophthalmol Ther 2021; 10:273-288. [PMID: 33548046 PMCID: PMC8079587 DOI: 10.1007/s40123-021-00330-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Accepted: 01/09/2021] [Indexed: 12/29/2022] Open
Abstract
Introduction The aim of this study was to compare the functional optical zone (FOZ) after correction of high myopic astigmatism and low myopic astigmatism by small-incision lenticule extraction (SMILE). Methods In this prospective study, 30 patients who received SMILE for high myopic astigmatism correction (cylinderical diopters ≤ − 2.0D) were enrolled in the high astigmatism group (HA). The control group comprised 40 patients who underwent SMILE for low myopic astigmatism correction (LA; cylinderical diopters ≥ − 0.5D). FOZ was delineated as the area outlined by a change of 0.5D relative to the power at the corneal vertex on the total corneal refractive power map. An ellipse-fitting program (MatLab) was used to calculate some parameters of the FOZ. Visual quality evaluations were also conducted, including evaluations of wavefront aberrations, optical quality, and intraocular scattering, and completion of a quality of life questionnaire. All of the right eyes were analyzed in the study. Results The preoperative average treatment spherical equivalent (− 5.77 ± 1.86D vs. − 6.49 ± 1.49D; P = 0.074), lenticule thickness (120.87 ± 23.27 μm vs. 118.53 ± 21.66 μm; P = 0.666), and programmed optical zone (6.58 ± 0.17 mm vs. 6.65 ± 0.18 mm; P = 0.104) were comparable between the HA and LA groups. The long axes (6.99 ± 1.14 mm vs. 5.32 ± 0.61 mm; P < 0.001), short axes (4.66 ± 0.96 mm vs. 4.23 ± 0.64 mm; P = 0.047), and area (25.90 ± 8.03 mm2 vs. 17.92 ± 4.36 mm2; P < 0.001) of the FOZ were significantly larger in the HA group than in the LA group. The centration of the FOZ were comparable between the two groups (0.62 ± 0.25 mm vs. 0.70 ± 0.25 mm; P = 0.194). Postoperative spherical aberration was lower in the HA group than in the LA group (0.07 ± 0.05 μm vs. 0.14 ± 0.10 μm; P = 0.001). There was no significant difference in the ocular scatter index (0.80 ± 0.46 vs. 0.73 ± 0.46; P = 0.447), modulated transfer function (MTF)cutoff (37.89 ± 9.79 cpd vs. 39.78 ± 7.45 cpd; P = 0.363), and Strehl in two dimensions (Strehl2D) ratio (0.20 ± 0.04 vs. 0.20 ± 0.04; P = 0.363) between the HA group and the LA group. There were no significant differences in the scores on quality of life between the HA and LA groups (45.88 ± 2.15 vs. 45.64 ± 1.84; P = 0.423). Correlation analysis revealed that increase in the spherical aberration was significantly correlated with the long axes, short axes and area in the FOZ in both groups. Conclusion With a comparable optical design and attempted correction in SMILE, the eyes with higher myopic astigmatism correction achieved larger FOZ than the eyes with lower myopic astigmatism correction. Consequently, less spherical aberration induction was created after higher myopic astigmatism correction. This result may be associated with less corneal volume sculpted by laser for the higher astigmatism treatment, leading to fewer biochemical responses and les change in corneal aspherity. Good retinal image quality and satisfied quality of life were achieved at a comparable level in both study groups.
Collapse
|
48
|
Pérez-Corral J, Cardona G, Piñero DP, Aradilla Y, García M. Should Overnight Orthokeratology Patients Wear Their Lenses During Their Afternoon Nap? Eye Contact Lens 2021; 47:91-97. [PMID: 32701767 DOI: 10.1097/icl.0000000000000732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/11/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE The purpose of this study was to evaluate changes in visual acuity, corneal curvature, elevation, pachymetry, and objective quality of vision of experienced orthokeratology patients using their contact lenses during a simulated 30-min afternoon nap. METHOD Twelve patients aged 30.8±8.3 years were recruited for the study, with a history of overnight orthokeratology of 27.4±23.0 months. Patients were instructed to close their eyes for 30 min while wearing their contact lenses or without lenses. Anterior corneal curvature, elevation, and corneal pachymetry were assessed with the Pentacam Scheimpflug System at 17 predefined corneal locations, and the HD Analyzer (Terrassa, Spain) was used to measure objective quality of vision. Measurements were conducted before eye closure (baseline), immediately after eye opening/lens removal (M1), and 30 min later (M2). RESULTS No statistically significant differences were found in anterior corneal curvature and elevation between baseline values and M1 or M2, with and without contact lenses. Corneal swelling at M1 was greater without contact lenses (change in central corneal thickness of 2.3%±3.1%, P=0.001) than with contact lenses (1.7%±1.3%, P<0.001). Recovery at M2 was slower when lenses were worn. A statistically significant improvement in objective quality of vision and visual acuity was found only when patients napped with their lenses. CONCLUSIONS Even if no significant changes were found in corneal curvature and elevation, patients of overnight orthokeratology may benefit from using their contact lenses during their afternoon nap in terms of objective quality of vision and visual acuity.
Collapse
Affiliation(s)
- Joan Pérez-Corral
- Department of Optics and Optometry (J.P.-C., G.C.), Universitat Politècnica de Catalunya, School of Optics and Optometry, Terrassa, Spain; Department of Optics, Pharmacology, and Anatomy (D.P.P.), University of Alicante, Alicante, Spain; and Department of Contact Lenses (Y.A., M.G.), Institut Català de Retina, Barcelona, Spain
| | | | | | | | | |
Collapse
|
49
|
Visual outcome, optical quality, and patient satisfaction with a new monofocal IOL, enhanced for intermediate vision: preliminary results. J Cataract Refract Surg 2021; 46:378-387. [PMID: 32050218 DOI: 10.1097/j.jcrs.0000000000000061] [Citation(s) in RCA: 100] [Impact Index Per Article: 33.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare visual outcomes, contrast sensitivity, optical quality, spectacle independence, and visual disturbances in patients implanted with 2 models of monofocal intraocular lenses (IOLs). SETTING Eye Clinic, Department of NEUROFARBA, University of Florence, Italy. DESIGN Prospective case series METHODS:: Patients without ocular comorbidities and corneal astigmatism less than 0.75 diopters (D) had cataract surgery with bilateral implantation of either of 2 monofocal IOLs, the Tecnis ZCB00 or the Tecnis Eyhance ICB00 (Johnson & Johnson Vision Care, Inc.). Six months postoperatively, monocular and binocular uncorrected and corrected (at 4 m) distance visual acuities, as well as uncorrected (UIVA), distance corrected, and corrected intermediate (at 66 cm) and near (at 40 cm) visual acuities were measured. Photopic contrast sensitivity, binocular defocus curve, objective scatter index (OSI), Strehl ratio, modulation transfer function (MTF) cutoff, halo and glare perception, and spectacle independence were also evaluated. RESULTS A total of 80 eyes of 40 patients were evaluated in this study. Although monocular and binocular uncorrected and corrected distance and near visual acuities were similar between groups, monocular and binocular UIVA were significantly higher in the Eyhance group. There were no statistically significant differences between the 2 groups in terms of photopic contrast sensitivity, OSI, MTF cutoff, Strehl ratio, and glare and halo perception. The ICB00 IOL provided better spectacle independence than the ZCB00 IOL for intermediate distance. CONCLUSIONS In patients without ocular comorbidities, the Eyhance ICB00 IOL provided better UIVA and higher intermediate spectacle independence without impairment of far vision and visual quality, compared with the ZCB00 IOL.
Collapse
|
50
|
Lu B, Zhu W, Fan Y, Shi D, Ma L. Utility of the optical quality analysis system for decision-making in Nd: YAG laser posterior capsulotomy in patients with light posterior capsule opacity. BMC Ophthalmol 2021; 21:7. [PMID: 33407218 PMCID: PMC7788843 DOI: 10.1186/s12886-020-01710-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Accepted: 10/29/2020] [Indexed: 11/18/2022] Open
Abstract
Background A prospective cohort study was performed to evaluate whether the Optical Quality Analysis System (OQAS) can serve as a valuable additional indicator for appropriate posterior capsulotomy referral. Methods One hundred and five eyes from 96 patients undergoing capsulotomy were divided into precapsulotomy logMAR CDVA ≤0.1 group and logMAR CDVA > 0.1 group. CDVA, and the Visual Function 14 index (VF-14) score were estimated before and 1 month after capsulotomy. The objective scattering index (OSI) value was measured by using the OQAS. Posterior capsule opacification (PCO) severity was assessed with Evaluation of PCO 2000 (EPCO 2000) software. Results In logMAR CDVA > 0.1 group, the correlations of OSI, logMAR CDVA, EPCO score and VF-14 score were very strong preoperatively. In logMAR CDVA ≤0.1 group, preoperatively, OSI was correlated with logMAR CDVA (r = 0.451), EPCO score (r = 0.789), and VF-14 score (r = 0.852). LogMAR CDVA has weak correlation with VF-14 score (r = − 0.384) and EPCO score (r = 0.566). VF-14 score was correlated with EPCO score (r = − 0.669). In the logMAR CDVA ≤0.1 group, there was no significant difference in logMAR CDVA between precapsulotomy and postcapsulotomy (P > 0.05). In the two groups, all the other optical quality parameters were significantly improved after capsulotomy (P < 0.05). In logMAR CDVA > 0.1 group, the area under the curve of the ROC of the OSI was 0.996 (P = 0.000). In logMAR CDVA ≤0.1 group, the area under the curve of the ROC of the OSI was 0.943 (P = 0.000). Conclusions The OSI was useful for evaluating of PCO and prediction of beneficial capsulotomy. Especially for patients with slight PCO and better visual acuity, OSI is more valuable than CDVA and completely objective examination. Trial registration The study protocol was registered at the Chinese Clinical Trial Registry. Register: ChiCTR1800018842 (Registered Date: October 13th, 2018).
Collapse
Affiliation(s)
- Bo Lu
- Department of Ophthalmology, the Fourth Affiliated Hospital of China Medical University, Eye Hospital of China Medical University, Shenyang City, 110005, Liaoning Province, China
| | - Weijie Zhu
- Department of Ophthalmology, the Fourth Affiliated Hospital of China Medical University, Eye Hospital of China Medical University, Shenyang City, 110005, Liaoning Province, China
| | - Yu Fan
- Department of Ophthalmology, the Fourth Affiliated Hospital of China Medical University, Eye Hospital of China Medical University, Shenyang City, 110005, Liaoning Province, China
| | - Dong Shi
- Department of Ophthalmology, the Fourth Affiliated Hospital of China Medical University, Eye Hospital of China Medical University, Shenyang City, 110005, Liaoning Province, China
| | - Liwei Ma
- Department of Ophthalmology, the Fourth Affiliated Hospital of China Medical University, Eye Hospital of China Medical University, Shenyang City, 110005, Liaoning Province, China. .,Aier Excellence Eye Hospital, Central South University Aier School of Ophthalmology, Shenyang City, 110001, Liaoning Province, China.
| |
Collapse
|