1
|
Genuardi MD, Wiegand M, Endres E, Opel O. Statistical analysis of parameters affecting Legionella and total cell growth in premise plumbing systems within buildings: A field study based on an empirical data set. Int J Hyg Environ Health 2024; 263:114456. [PMID: 39276424 DOI: 10.1016/j.ijheh.2024.114456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Revised: 07/18/2024] [Accepted: 09/06/2024] [Indexed: 09/17/2024]
Abstract
During the storage and distribution of water in buildings, the excessive growth of pathogens can deteriorate the quality of drinking water. This study aims to investigate the factors influencing this growth and propose technical measures for prevention. The analysis is based on an empirical data set comprising 1361 samples from 204 domestic premise plumbing systems. In 14 systems, ultrafiltration plants were installed as microbiological barriers. Legionella cultivation and flow cytometry were used to determine microbiological properties. The study identified elevated total cell counts in tapping valves and pipe end lines in numerous premise plumbing systems, indicating prolonged water stagnation prior to sampling, which facilitates microbiological growth. Higher contamination rates were observed in these systems, with peripheral taps often being contaminated in lieu of the entire system. These systems were classified as microbiologically unstable due to the relevantly higher total cell numbers at hot water taps compared to the hot water tank (>25%). Furthermore, these systems exhibited a Legionella contamination rate that was 22.3% higher than in microbiologically stable systems. In some cases, peripheral contaminations may not accurately represent the entire premise plumbing system. Increasing the discard volume during sampling from 1 L to 3-5 L could provide more precise results during standard testing. Legionella species were primarily detected in the first 1 L of water after tap activation. Additionally, statistically significant relationships were observed between direct temperature and total cell number, as well as between the presence of ultrafiltration and total cell numbers at cold water taps.
Collapse
Affiliation(s)
- Marco Daniele Genuardi
- Institute for the Transformation of the Energy System, West Coast University of Applied Sciences, Markt 18, 25746, Heide, Germany.
| | - Marlies Wiegand
- Institute for the Transformation of the Energy System, West Coast University of Applied Sciences, Markt 18, 25746, Heide, Germany
| | - Elisabeth Endres
- Institute for Building Climatology and Energy of Architecture, Technische Universität Braunschweig, Mühlenpfordstraße 23, 38106, Braunschweig, Germany
| | - Oliver Opel
- Institute for the Transformation of the Energy System, West Coast University of Applied Sciences, Markt 18, 25746, Heide, Germany
| |
Collapse
|
2
|
Lippai A, Ágoston C, Szunyogh L. The impact of stagnation on the microbial quality of constructed water systems after COVID-19 shutdowns. Biol Futur 2024; 75:361-370. [PMID: 39048893 DOI: 10.1007/s42977-024-00231-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Accepted: 07/14/2024] [Indexed: 07/27/2024]
Abstract
In response to COVID-19 pandemic, governments all over the world limited the movement of people and mandated temporary closure of different institutions. While, these measures helped to reduce the spread of COVID-19, stagnant water can cause water quality deterioration. Stagnation is considered in context with the proliferation of pathogenic and facultatively pathogenic bacteria which pose potential health risks to humans. The objective of this study was to document the hygienic microbiological status of different water systems after the first shutdowns (between 18th March 2020 and 18th May 2020) in Hungary in comparison with a reference period (between 3rd January 2020 to 17th March). During the reference period drinking waters were compliant > 95% of total samples to the parametric values. After the short period shutdowns, the ratio of tnon-compliant drinking water samples was 6.6%: mainly Pseudomonas aeruginosa (7%) and coliform bacteria (5%) resulted poor water quality. The microscopic analysis of drinking waters showed that after low water demand the values of non-compliant samples also increased due to the proliferation of Amoebozoa and other Protozoa species. The compliant pool waters' ratio was also high in the reference period (97-99%), while after the shutdowns more samples were positive in both pool operation type (fill-and-drain pools and pools with recirculation) due to the proliferation of P. aeruginosa (14%) and micrococci (12%). Legionella non-compliant samples in hot tap water did not show significant difference during both studied periods (15%) although after stagnation the Legionella CFU (colony forming unit) values of the samples increased markedly.
Collapse
Affiliation(s)
- Anett Lippai
- Biokör Technology and Environmental Protection Ltd., Bláthy Ottó utca 41., Budapest, 1089, Hungary.
| | - Csaba Ágoston
- Biokör Technology and Environmental Protection Ltd., Bláthy Ottó utca 41., Budapest, 1089, Hungary
| | - Lilla Szunyogh
- Budapest Spas cPlc., Orlay utca 5-7., Budapest, 1117, Hungary
| |
Collapse
|
3
|
Lee-Masi M, Coulter C, Chow SJ, Zaitchik B, Jacangelo JG, Exum NG, Schwab KJ. Two-year evaluation of Legionella in an aging residential building: Assessment of multiple potable water remediation approaches. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 941:173710. [PMID: 38830423 PMCID: PMC11238177 DOI: 10.1016/j.scitotenv.2024.173710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 05/30/2024] [Accepted: 05/31/2024] [Indexed: 06/05/2024]
Abstract
Legionella is an opportunistic waterborne pathogen that is difficult to eradicate in colonized drinking water pipes. Legionella control is further challenged by aging water infrastructure and lack of evidence-based guidance for building treatment. This study assessed multiple premise water remediation approaches designed to reduce Legionella pneumophila within a residential building located in an aging, urban drinking water system over a two-year period. Samples (n = 745) were collected from hot and cold-water lines and quantified via most probable number culture. Building-level treatment approaches included three single heat shocks, three single chemical shocks, and continuous low-level chemical disinfection in the potable water system. The building was highly colonized with L. pneumophila with 71 % L. pneumophila positivity. Single heat shocks had a statistically significant L. pneumophila reduction one day post treatment but no significant L. pneumophila reduction at one week, two weeks, and four weeks post treatment. The first two chemical shocks resulted in statistically significant L. pneumophila reduction at two days and four weeks post treatment, but there was a significant L. pneumophila increase at four weeks following the third chemical shock. Continuous low-level chemical disinfection resulted in statistically significant L. pneumophila reduction at ten weeks post treatment implementation. This demonstrates that in a building highly colonized with L. pneumophila, sustained remediation is best achieved using continuous low-level chemical treatment.
Collapse
Affiliation(s)
- Monica Lee-Masi
- Department of Environmental Health & Engineering, Johns Hopkins Bloomberg School of Public Health, 615 N. Wolfe St, Baltimore, MD 21205, United States
| | - Caroline Coulter
- Department of Environmental Health & Engineering, Johns Hopkins Bloomberg School of Public Health, 615 N. Wolfe St, Baltimore, MD 21205, United States
| | - Steven J Chow
- Department of Environmental Health & Engineering, Johns Hopkins Bloomberg School of Public Health, 615 N. Wolfe St, Baltimore, MD 21205, United States
| | - Benjamin Zaitchik
- Department of Earth and Planetary Sciences, Johns Hopkins Krieger School of Arts and Sciences, 3400 N. Charles St., Baltimore, MD 21218, United States
| | - Joseph G Jacangelo
- Department of Environmental Health & Engineering, Johns Hopkins Bloomberg School of Public Health, 615 N. Wolfe St, Baltimore, MD 21205, United States; Stantec, 1299 Pennsylvania Ave. NW Ste 405, Washington, DC 20004, United States
| | - Natalie G Exum
- Department of Environmental Health & Engineering, Johns Hopkins Bloomberg School of Public Health, 615 N. Wolfe St, Baltimore, MD 21205, United States
| | - Kellogg J Schwab
- Department of Environmental Health & Engineering, Johns Hopkins Bloomberg School of Public Health, 615 N. Wolfe St, Baltimore, MD 21205, United States.
| |
Collapse
|
4
|
Grimard-Conea M, Bédard E, Prévost M. Can free chlorine residuals entering building plumbing systems really be maintained to prevent microbial growth? THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 939:173651. [PMID: 38821274 DOI: 10.1016/j.scitotenv.2024.173651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 05/22/2024] [Accepted: 05/28/2024] [Indexed: 06/02/2024]
Abstract
Secondary disinfection aims to prevent microbial regrowth during distribution by maintaining disinfectant residuals in water systems. However, multi-factorial interactions contribute to free chlorine decay in distribution systems, and even more so in building plumbing. Assembling 1737 samples from nine large institutional buildings, a meta-analysis was conducted to determine whether building managers can actively rely on incoming free chlorine residuals to prevent in-building microbial amplification. Findings showed that free chlorine concentrations in first draws met the 0.2 mg/L common guide level in respectively 26 %, 6 % and 2 % of cold, tepid and hot water samples, whereas flushing for 2-60 min only significantly increased this ratio in cold water (83 %), without reaching background levels found in service lines. Free chlorine was significantly but weakly (R≤ 0.2) correlated to adenosine triphosphate, heterotrophic plate count and total and intact cell counts, thus evidencing that residuals contributed to decreased culturable and viable biomass. Detection of culturable Legionella pneumophila spanning over a 4-log distribution solely occurred when free chlorine levels were below 0.2 mg/L, but no such trend could be distinguished clearly for culturable Pseudomonas aeruginosa. Water temperatures below 20 °C and >60 °C also completely prevented L. pneumophila detection. Overall, the majority of elevated microbial counts were measured in distal sites and in tepid and hot water, where free chlorine is less likely to be present due to stagnation and increased temperature. Therefore, building managers cannot solely rely on this chemical barrier to mitigate bacterial growth in bulk water.
Collapse
Affiliation(s)
| | - Emilie Bédard
- Department of Civil Engineering, Polytechnique Montreal, Montreal, QC H3C 3A7, Canada.
| | - Michèle Prévost
- Department of Civil Engineering, Polytechnique Montreal, Montreal, QC H3C 3A7, Canada.
| |
Collapse
|
5
|
Clements E, Crank K, Nerenberg R, Atkinson A, Gerrity D, Hannoun D. Quantitative Microbial Risk Assessment Framework Incorporating Water Ages with Legionella pneumophila Growth Rates. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:6540-6551. [PMID: 38574283 PMCID: PMC11025131 DOI: 10.1021/acs.est.4c01208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 03/20/2024] [Accepted: 03/21/2024] [Indexed: 04/06/2024]
Abstract
Water age in drinking water systems is often used as a proxy for water quality but is rarely used as a direct input in assessing microbial risk. This study directly linked water ages in a premise plumbing system to concentrations of Legionella pneumophila via a growth model. In turn, the L. pneumophila concentrations were used for a quantitative microbial risk assessment to calculate the associated probabilities of infection (Pinf) and clinically severe illness (Pcsi) due to showering. Risk reductions achieved by purging devices, which reduce water age, were also quantified. The median annual Pinf exceeded the commonly used 1 in 10,000 (10-4) risk benchmark in all scenarios, but the median annual Pcsi was always 1-3 orders of magnitude below 10-4. The median annual Pcsi was lower in homes with two occupants (4.7 × 10-7) than with one occupant (7.5 × 10-7) due to more frequent use of water fixtures, which reduced water ages. The median annual Pcsi for homes with one occupant was reduced by 39-43% with scheduled purging 1-2 times per day. Smart purging devices, which purge only after a certain period of nonuse, maintained these lower annual Pcsi values while reducing additional water consumption by 45-62%.
Collapse
Affiliation(s)
- Emily Clements
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| | - Katherine Crank
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| | - Robert Nerenberg
- Department
of Civil & Environmental Engineering & Earth Science, University of Notre Dame, 156 Fitzpatrick Hall, Notre
Dame, Indiana 46556, United States
| | - Ariel Atkinson
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| | - Daniel Gerrity
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| | - Deena Hannoun
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| |
Collapse
|
6
|
Ra K, Proctor C, Ley C, Angert D, Noh Y, Odimayomi T, Whelton AJ. Four buildings and a flush: Lessons from degraded water quality and recommendations on building water management. ENVIRONMENTAL SCIENCE AND ECOTECHNOLOGY 2024; 18:100314. [PMID: 37854462 PMCID: PMC10579424 DOI: 10.1016/j.ese.2023.100314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 09/07/2023] [Accepted: 09/11/2023] [Indexed: 10/20/2023]
Abstract
A reduction in building occupancy can lead to stagnant water in plumbing, and the potential consequences for water quality have gained increasing attention. To investigate this, a study was conducted during the COVID-19 pandemic, focusing on water quality in four institutional buildings. Two of these buildings were old (>58 years) and large (>19,000 m2), while the other two were new (>13 years) and small (<11,000 m2). The study revealed significant decreases in water usage in the small buildings, whereas usage remained unchanged in the large buildings. Initial analysis found that residual chlorine was rarely detectable in cold/drinking water samples. Furthermore, the pH, dissolved oxygen, total organic carbon, and total cell count levels in the first draw of cold water samples were similar across all buildings. However, the ranges of heavy metal concentrations in large buildings were greater than observed in small buildings. Copper (Cu), lead (Pb), and manganese (Mn) sporadically exceeded drinking water limits at cold water fixtures, with maximum concentrations of 2.7 mg Cu L-1, 45.4 μg Pb L-1, 1.9 mg Mn L-1. Flushing the plumbing for 5 min resulted in detectable residual at fixtures in three buildings, but even after 125 min of flushing in largest and oldest building, no residual chlorine was detected at the fixture closest to the building's point of entry. During the pandemic, the building owner conducted fixture flushing, where one to a few fixtures were operated per visit in buildings with hundreds of fixtures and multiple floors. However, further research is needed to understand the fundamental processes that control faucet water quality from the service line to the faucet. In the absence of this knowledge, building owners should create and use as-built drawings to develop flushing plans and conduct periodic water testing.
Collapse
Affiliation(s)
- Kyungyeon Ra
- Lyles School of Civil Engineering, Purdue University, 550 Stadium Mall Drive, West Lafayette, IN, 47907, USA
| | - Caitlin Proctor
- Agricultural and Biological Engineering, Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | - Christian Ley
- Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Civil and Environmental Engineering, University of Colorado, 1111 Engineering Drive, Boulder, CO, 80309, USA
| | - Danielle Angert
- Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Civil, Architectural and Environmental Engineering, University of Texas, 301E E Dean Keeton Street, Austin, TX, 78712, USA
| | - Yoorae Noh
- Lyles School of Civil Engineering, Purdue University, 550 Stadium Mall Drive, West Lafayette, IN, 47907, USA
| | - Tolulope Odimayomi
- Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Civil and Environmental Engineering, Virginia Tech, 750 Drillfield Drive, Blacksburg, VA, 24061, USA
| | - Andrew J. Whelton
- Lyles School of Civil Engineering, Division of Environmental and Ecological Engineering, Purdue University, 550 Stadium Mall Drive, West Lafayette, IN, 47907, USA
| |
Collapse
|
7
|
Abkar L, Moghaddam HS, Fowler SJ. Microbial ecology of drinking water from source to tap. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 908:168077. [PMID: 37914126 DOI: 10.1016/j.scitotenv.2023.168077] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 10/20/2023] [Accepted: 10/21/2023] [Indexed: 11/03/2023]
Abstract
As drinking water travels from its source, through various treatment processes, hundreds to thousands of kilometres of distribution network pipes, to the taps in private homes and public buildings, it is exposed to numerous environmental changes, as well as other microbes living in both water and on surfaces. This review aims to identify the key locations and factors that are associated with changes in the drinking water microbiome throughout conventional urban drinking water systems from the source to the tap water. Over the past 15 years, improvements in cultivation-independent methods have enabled studies that allow us to answer such questions. As a result, we are beginning to move towards predicting the impacts of disturbances and interventions resulting ultimately in management of drinking water systems and microbial communities rather than mere observation. Many challenges still exist to achieve effective management, particularly within the premise plumbing environment, which exhibits diverse and inconsistent conditions that may lead to alterations in the microbiota, potentially presenting public health risks. Finally, we recommend the establishment of global collaborative projects on the drinking water microbiome that will enhance our current knowledge and lead to tools for operators and researchers alike to improve global access to high-quality drinking water.
Collapse
Affiliation(s)
- Leili Abkar
- Civil Engineering Department, University of British Columbia, Canada.
| | | | - S Jane Fowler
- Department of Biological Sciences, Simon Fraser University, Canada.
| |
Collapse
|
8
|
Cazals M, Bédard E, Soucy C, Savard P, Prévost M. How clean is your ice machine? Revealing microbial amplification and presence of opportunistic pathogens in hospital ice-water machines. J Hosp Infect 2023; 141:9-16. [PMID: 37604277 DOI: 10.1016/j.jhin.2023.08.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Revised: 07/18/2023] [Accepted: 08/05/2023] [Indexed: 08/23/2023]
Abstract
BACKGROUND Ice machines in healthcare facilities have been suspected and even linked to outbreaks and pseudo-outbreaks. Guidelines exist for maintenance of these devices but there is no clear independent infection control standard, and little is known about their microbial contamination. AIM To evaluate the microbial contamination, amplification, and presence of opportunistic pathogens in ice-water machines in a healthcare facility. METHODS Concentrations of general microbial indicators (heterotrophic plate counts (HPC), total and intact cells), faecal indicators (enterococci) and opportunistic pathogens (Pseudomonas aeruginosa, non-tuberculous mycobacteria (NTM), Candida spp.) were measured in 36 ice-water machines on patient wards of a 772-bed hospital. Profile sampling was performed on five ice-water machines and adjacent faucets to identify sites of microbial proliferation. FINDINGS Candida spp. were found in half of ice-water samples while enterococci and P. aeruginosa were present in six and 11 drain inlets respectively. NTM were measured in all ice-water samples and 35 out of 36 biofilms. Pre-filters and ice machines are sites for additional amplification: NTM densities were on average 1.3 log10 higher in water of ice machine flushed 5 min compared to flushed adjacent tap water. CONCLUSION Ice machine design needs to be adapted to reduce microbial proliferation. The absence of correlation between HPC densities (current microbial indicators) and NTM concentrations suggests a need for cleaning efficiency indicators better correlated with opportunistic pathogens. Cleaning and disinfection guidelines of ice machines in healthcare facilities need to be improved, especially when ice is given to the most vulnerable patients, and NTM may be an efficiency indicator.
Collapse
Affiliation(s)
- M Cazals
- Civil, Geological and Mining Engineering Department, Polytechnique Montréal, Montreal, Canada.
| | - E Bédard
- Civil, Geological and Mining Engineering Department, Polytechnique Montréal, Montreal, Canada
| | - C Soucy
- Infection Prevention and Control, University of Montreal Hospital Centre (CHUM), Montreal, Canada
| | - P Savard
- Infection Prevention and Control, University of Montreal Hospital Centre (CHUM), Montreal, Canada; Department of Microbiology, Infectious Diseases and Immunology and University of Montreal Hospital Centre Research Centre (CRCHUM), University of Montreal, Canada
| | - M Prévost
- Civil, Geological and Mining Engineering Department, Polytechnique Montréal, Montreal, Canada
| |
Collapse
|
9
|
Clements E, Irwin C, Taflanidis A, Bibby K, Nerenberg R. Impact of fixture purging on water age and excess water usage, considering stochastic water demands. WATER RESEARCH 2023; 245:120643. [PMID: 37748346 DOI: 10.1016/j.watres.2023.120643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Revised: 09/13/2023] [Accepted: 09/17/2023] [Indexed: 09/27/2023]
Abstract
Higher water ages are linked with water quality decline as chlorine dissipates, temperatures become more favorable for microbial growth, and metals and organic matter leach from the pipes. Water fixtures with automated purging devices can limit water age in premise plumbing systems, but also increase water use. To develop purging strategies that lower age while also minimizing water use, the stochastic nature of water demands must be considered. In this research, a hydraulic plumbing network model, with stochastic demands at fixtures, was used to compare water age and water use for five purging conditions: purging at regular intervals, "smart" purging (considering the time of last use), purging with different volumes of water, purging at different fixtures, and the purging with different levels of home occupancy. Higher purging frequency and volume resulted in lower water ages, but higher water use. Purging greatly reduced the variability in water ages, avoiding extreme ages entirely. Water age was minimized by scheduling the purging around occupancy behavior, such as before the occupants wake up or return from work. Scheduled purging used more water than smart purging. Purging after 12 h of nonuse used only 55% of the additional water required for purging every 12 h. Purging after 24 h of nonuse at the kitchen tap and shower used only 38% of the additional water required for purging every 24 h, while maintaining lower water ages and removing the variability in water ages. While larger purging volumes had a greater impact on water age, there were diminishing returns. Purging has a larger impact on low-occupancy homes because fixtures have less frequent use. Overall, this research provides a methodology to compare purging strategies that minimize both water age and water use. While the numerical results presented here are only valid for the specific layout and usage habits, they provide insights and trends applicable to other cases.
Collapse
Affiliation(s)
- Emily Clements
- Department of Civil and Environmental Engineering and Earth Sciences 156 Fitzpatrick Hall, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Christopher Irwin
- Department of Civil and Environmental Engineering and Earth Sciences 156 Fitzpatrick Hall, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Alexandros Taflanidis
- Department of Civil and Environmental Engineering and Earth Sciences 156 Fitzpatrick Hall, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Kyle Bibby
- Department of Civil and Environmental Engineering and Earth Sciences 156 Fitzpatrick Hall, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Robert Nerenberg
- Department of Civil and Environmental Engineering and Earth Sciences 156 Fitzpatrick Hall, University of Notre Dame, Notre Dame, IN 46556, USA.
| |
Collapse
|
10
|
Maillard JY, Centeleghe I. How biofilm changes our understanding of cleaning and disinfection. Antimicrob Resist Infect Control 2023; 12:95. [PMID: 37679831 PMCID: PMC10483709 DOI: 10.1186/s13756-023-01290-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Accepted: 08/15/2023] [Indexed: 09/09/2023] Open
Abstract
Biofilms are ubiquitous in healthcare settings. By nature, biofilms are less susceptible to antimicrobials and are associated with healthcare-associated infections (HAI). Resistance of biofilm to antimicrobials is multifactorial with the presence of a matrix composed of extracellular polymeric substances and eDNA, being a major contributing factor. The usual multispecies composition of environmental biofilms can also impact on antimicrobial efficacy. In healthcare settings, two main types of biofilms are present: hydrated biofilms, for example, in drains and parts of some medical devices and equipment, and environmental dry biofilms (DSB) on surfaces and possibly in medical devices. Biofilms act as a reservoir for pathogens including multi-drug resistant organisms and their elimination requires different approaches. The control of hydrated (drain) biofilms should be informed by a reduction or elimination of microbial bioburden together with measuring biofilm regrowth time. The control of DSB should be measured by a combination of a reduction or elimination in microbial bioburden on surfaces together with a decrease in bacterial transfer post-intervention. Failure to control biofilms increases the risk for HAI, but biofilms are not solely responsible for disinfection failure or shortcoming. The limited number of standardised biofilm efficacy tests is a hindrance for end users and manufacturers, whilst in Europe there are no approved standard protocols. Education of stakeholders about biofilms and ad hoc efficacy tests, often academic in nature, is thus paramount, to achieve a better control of biofilms in healthcare settings.
Collapse
Affiliation(s)
- Jean-Yves Maillard
- School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Redwood Building, King Edward VII Avenue, Cardiff, CF10 3NB, Wales, UK.
| | - Isabella Centeleghe
- School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Redwood Building, King Edward VII Avenue, Cardiff, CF10 3NB, Wales, UK
| |
Collapse
|
11
|
Lee-Masi M, Coulter C, Chow SJ, Zaitchik B, Jacangelo JG, Exum NG, Schwab KJ. Two-Year Evaluation of Legionella in an Aging Residential Building: Assessment of Multiple Potable Water Remediation Approaches. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.07.19.23292444. [PMID: 37502988 PMCID: PMC10371102 DOI: 10.1101/2023.07.19.23292444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/29/2023]
Abstract
Legionella is an opportunistic waterborne pathogen that is difficult to eradicate in colonized drinking water pipes. Legionella control is further challenged by aging water infrastructure and lack of evidence-based guidance for building treatment. This study assessed multiple premise water remediation approaches designed to reduce Legionella pneumophila (Lp) within a residential building located in an aging, urban drinking water system over a two-year period. Samples (n=745) were collected from hot and cold-water lines and quantified via most probable number culture. Building-level treatment approaches included three single heat shocks (HS), three single chemical shocks (CS), and continuous low-level chemical disinfection (CCD) in the potable water system. The building was highly colonized with Lp with 71% Lp positivity. Single HS had a statistically significant Lp reduction one day post treatment but no significant Lp reduction one, two, and four weeks post treatment. The first two CS resulted in statistically significant Lp reduction at two days and four weeks post treatment, but there was a significant Lp increase at four weeks following the third CS. CCD resulted in statistically significant Lp reduction ten weeks post treatment implementation. This demonstrates that in a building highly colonized with Lp, sustained remediation is best achieved using CCD.
Collapse
Affiliation(s)
- Monica Lee-Masi
- Department of Environmental Health & Engineering, Johns Hopkins Bloomberg School of Public Health, 21205, Baltimore, Maryland, United States
| | - Caroline Coulter
- Department of Environmental Health & Engineering, Johns Hopkins Bloomberg School of Public Health, 21205, Baltimore, Maryland, United States
| | - Steven J. Chow
- Department of Environmental Health & Engineering, Johns Hopkins Bloomberg School of Public Health, 21205, Baltimore, Maryland, United States
| | - Benjamin Zaitchik
- Department of Earth and Planetary Sciences, Johns Hopkins Krieger School of Arts and Sciences, 21218, Baltimore, Maryland, United States
| | - Joseph G. Jacangelo
- Department of Environmental Health & Engineering, Johns Hopkins Bloomberg School of Public Health, 21205, Baltimore, Maryland, United States
- Department of Earth and Planetary Sciences, Johns Hopkins Krieger School of Arts and Sciences, 21218, Baltimore, Maryland, United States
| | - Natalie G. Exum
- Department of Environmental Health & Engineering, Johns Hopkins Bloomberg School of Public Health, 21205, Baltimore, Maryland, United States
| | - Kellogg J. Schwab
- Department of Environmental Health & Engineering, Johns Hopkins Bloomberg School of Public Health, 21205, Baltimore, Maryland, United States
| |
Collapse
|
12
|
Nisar MA, Ros KE, Brown MH, Bentham R, Best G, Xi J, Hinds J, Whiley H. Stagnation arising through intermittent usage is associated with increased viable but non culturable Legionella and amoeba hosts in a hospital water system. Front Cell Infect Microbiol 2023; 13:1190631. [PMID: 37351181 PMCID: PMC10282743 DOI: 10.3389/fcimb.2023.1190631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Accepted: 05/18/2023] [Indexed: 06/24/2023] Open
Abstract
Hospital water systems are a significant source of Legionella, resulting in the potentially fatal Legionnaires' disease. One of the biggest challenges for Legionella management within these systems is that under unfavorable conditions Legionella transforms itself into a viable but non culturable (VBNC) state that cannot be detected using the standard methods. This study used a novel method (flow cytometry-cell sorting and qPCR [VFC+qPCR] assay) concurrently with the standard detection methods to examine the effect of temporary water stagnation, on Legionella spp. and microbial communities present in a hospital water system. Water samples were also analyzed for amoebae using culture and Vermamoeba vermiformis and Acanthamoeba specific qPCR. The water temperature, number and duration of water flow events for the hand basins and showers sampled was measured using the Enware Smart Flow® monitoring system. qPCR analysis demonstrated that 21.8% samples were positive for Legionella spp., 21% for L. pneumophila, 40.9% for V. vermiformis and 4.2% for Acanthamoeba. All samples that were Legionella spp. positive using qPCR (22%) were also positive for VBNC Legionella spp.; however, only 2.5% of samples were positive for culturable Legionella spp. 18.1% of the samples were positive for free-living amoebae (FLA) using culture. All samples positive for Legionella spp. were also positive for FLA. Samples with a high heterotrophic plate count (HPC ≥ 5 × 103 CFU/L) were also significantly associated with high concentrations of Legionella spp. DNA, VBNC Legionella spp./L. pneumophila (p < 0.01) and V. vermiformis (p < 0.05). Temporary water stagnation arising through intermittent usage (< 2 hours of usage per month) significantly (p < 0.01) increased the amount of Legionella spp. DNA, VBNC Legionella spp./L. pneumophila, and V. vermiformis; however, it did not significantly impact the HPC load. In contrast to stagnation, no relationship was observed between the microbes and water temperature. In conclusion, Legionella spp. (DNA and VBNC) was associated with V. vermiformis, heterotrophic bacteria, and stagnation occurring through intermittent usage. This is the first study to monitor VBNC Legionella spp. within a hospital water system. The high percentage of false negative Legionella spp. results provided by the culture method supports the use of either qPCR or VFC+qPCR to monitor Legionella spp. contamination within hospital water systems.
Collapse
Affiliation(s)
- Muhammad Atif Nisar
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | - Kirstin E. Ros
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | - Melissa H. Brown
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
- Australian Research Council Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia
| | - Richard Bentham
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | - Giles Best
- College of Medicine and Public Health, Flinders University, Bedford Park, SA, Australia
- Flow Cytometry Facility, Flinders University, Bedford Park, SA, Australia
| | - James Xi
- Enware Australia Pty Ltd., Caringbah, NSW, Australia
| | - Jason Hinds
- Enware Australia Pty Ltd., Caringbah, NSW, Australia
| | - Harriet Whiley
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
- Australian Research Council Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia
| |
Collapse
|
13
|
Grimard-Conea M, Prévost M. Controlling Legionella pneumophila in Showerheads: Combination of Remedial Intervention and Preventative Flushing. Microorganisms 2023; 11:1361. [PMID: 37374862 DOI: 10.3390/microorganisms11061361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 05/17/2023] [Accepted: 05/20/2023] [Indexed: 06/29/2023] Open
Abstract
Shock chlorination and remedial flushing are suggested to address Legionella pneumophila (Lp) contamination in buildings or during their (re)commissioning. However, data on general microbial measurements (adenosine tri-phosphate [ATP], total cell counts [TCC]), and the abundance of Lp are lacking to support their temporary implementation with variable water demands. In this study, the weekly short-term (3-week) impact of shock chlorination (20-25 mg/L free chlorine, 16 h) or remedial flushing (5-min flush) combined with distinct flushing regimes (daily, weekly, stagnant) was investigated in duplicates of showerheads in two shower systems. Results showed that the combination of stagnation and shock chlorination prompted biomass regrowth, with ATP and TCC in the first draws reaching large regrowth factors of 4.31-7.07-fold and 3.51-5.68-fold, respectively, from baseline values. Contrastingly, remedial flushing followed by stagnation generally resulted in complete or larger regrowth in Lp culturability and gene copies (gc). Irrespective of the intervention, daily flushed showerheads resulted in significantly (p < 0.05) lower ATP and TCC, as well as lower Lp concentrations than weekly flushes, in general. Nonetheless, Lp persisted at concentrations ranging from 11 to 223 as the most probable number per liter (MPN/L) and in the same order of magnitude (103-104 gc/L) than baseline values after remedial flushing, despite daily/weekly flushing, unlike shock chlorination which suppressed Lp culturability (down 3-log) for two weeks and gene copies by 1-log. This study provides insights on the most optimal short-term combination of remedial and preventative strategies that can be considered pending the implementation of suitable engineering controls or building-wide treatment.
Collapse
Affiliation(s)
- Marianne Grimard-Conea
- Industrial Chair in Drinking Water, Department of Civil, Mining and Geological Engineering, Polytechnique Montreal, Montreal, QC H3C 3A7, Canada
| | - Michèle Prévost
- Industrial Chair in Drinking Water, Department of Civil, Mining and Geological Engineering, Polytechnique Montreal, Montreal, QC H3C 3A7, Canada
| |
Collapse
|
14
|
Vosloo S, Huo L, Chauhan U, Cotto I, Gincley B, Vilardi KJ, Yoon B, Bian K, Gabrielli M, Pieper KJ, Stubbins A, Pinto AJ. Gradual Recovery of Building Plumbing-Associated Microbial Communities after Extended Periods of Altered Water Demand during the COVID-19 Pandemic. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:3248-3259. [PMID: 36795589 PMCID: PMC9969676 DOI: 10.1021/acs.est.2c07333] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 02/06/2023] [Accepted: 02/06/2023] [Indexed: 06/18/2023]
Abstract
COVID-19 pandemic-related building restrictions heightened drinking water microbiological safety concerns post-reopening due to the unprecedented nature of commercial building closures. Starting with phased reopening (i.e., June 2020), we sampled drinking water for 6 months from three commercial buildings with reduced water usage and four occupied residential households. Samples were analyzed using flow cytometry and full-length 16S rRNA gene sequencing along with comprehensive water chemistry characterization. Prolonged building closures resulted in 10-fold higher microbial cell counts in the commercial buildings [(2.95 ± 3.67) × 105 cells mL-1] than in residential households [(1.11 ± 0.58) × 104 cells mL-1] with majority intact cells. While flushing reduced cell counts and increased disinfection residuals, microbial communities in commercial buildings remained distinct from those in residential households on the basis of flow cytometric fingerprinting [Bray-Curtis dissimilarity (dBC) = 0.33 ± 0.07] and 16S rRNA gene sequencing (dBC = 0.72 ± 0.20). An increase in water demand post-reopening resulted in gradual convergence in microbial communities in water samples collected from commercial buildings and residential households. Overall, we find that the gradual recovery of water demand played a key role in the recovery of building plumbing-associated microbial communities as compared to short-term flushing after extended periods of reduced water demand.
Collapse
Affiliation(s)
- Solize Vosloo
- Department
of Civil and Environmental Engineering, Northeastern University, 360 Huntington Avenue, Boston, Massachusetts 021115, United States
| | - Linxuan Huo
- School
of Civil and Environmental Engineering, Georgia Institute of Technology, 311 Ferst Drive, Atlanta, Georgia 30318, United States
| | - Umang Chauhan
- Department
of Civil and Environmental Engineering, Northeastern University, 360 Huntington Avenue, Boston, Massachusetts 021115, United States
| | - Irmarie Cotto
- Department
of Civil and Environmental Engineering, Northeastern University, 360 Huntington Avenue, Boston, Massachusetts 021115, United States
| | - Benjamin Gincley
- School
of Civil and Environmental Engineering, Georgia Institute of Technology, 311 Ferst Drive, Atlanta, Georgia 30318, United States
| | - Katherine J. Vilardi
- Department
of Civil and Environmental Engineering, Northeastern University, 360 Huntington Avenue, Boston, Massachusetts 021115, United States
| | - Bryan Yoon
- Department
of Civil and Environmental Engineering, Northeastern University, 360 Huntington Avenue, Boston, Massachusetts 021115, United States
| | - Kaiqin Bian
- School
of Civil and Environmental Engineering, Georgia Institute of Technology, 311 Ferst Drive, Atlanta, Georgia 30318, United States
| | - Marco Gabrielli
- Dipartimento
di Ingegneria Civile e Ambientale - Sezione Ambientale, Politecnico di Milano, 20133 Milan, Italy
| | - Kelsey J. Pieper
- Department
of Civil and Environmental Engineering, Northeastern University, 360 Huntington Avenue, Boston, Massachusetts 021115, United States
| | - Aron Stubbins
- Department
of Civil and Environmental Engineering, Northeastern University, 360 Huntington Avenue, Boston, Massachusetts 021115, United States
| | - Ameet J. Pinto
- School
of Civil and Environmental Engineering, Georgia Institute of Technology, 311 Ferst Drive, Atlanta, Georgia 30318, United States
| |
Collapse
|
15
|
Schalli M, Kogler B, Miorini T, Gehrer M, Reinthaler FF. High-Speed Dental Instruments: An Investigation of Protein-Contaminated Dental Handpieces with the Bicinchoninic Acid Assay in Dental Offices in Styria, Austria. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:1670. [PMID: 36767036 PMCID: PMC9914004 DOI: 10.3390/ijerph20031670] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/09/2023] [Accepted: 01/15/2023] [Indexed: 06/18/2023]
Abstract
Due to permanent contact with bodily secretions such as blood and saliva, the dental workplace poses a high risk of infection for patients as well as for personnel. High-speed dental instruments are still considered one of the major hygienic risks, as the high-speed rotation of the attachments leads to the retraction of infectious material from patients' oral cavities. The aim of this study was to investigate the extent to which dental handpieces are contaminated after use. Spray-water samples were taken from different handpieces used in seven dental offices and protein concentrations were measured photometrically. In the first part of the study, samples were collected from each handpiece before and after the treatment of the patients. Additionally, the changes in protein concentration after consecutive treatments in which the same high-speed dental instrument was used were investigated. The results demonstrated measurable protein concentrations in 91.2% of a total of 398 samples, and 96.4% of the spray-water samples taken after treatment showed a discrepancy from the initial measured protein concentration. In 68.4% an increase in protein concentration was observed, whereas in 27.9% a decrease was measured. In conclusion, the internal contamination of high-speed dental instruments frequently occurs in daily usage and consequently may lead to the transmission of infectious agents by flushing the contaminated water out of the spray water tubes. Moreover, it must be pointed out that internal cleansing of handpieces is insufficient and that a final mechanical disinfection is indispensable.
Collapse
Affiliation(s)
- Michael Schalli
- Department for Water-Hygiene and Micro-Ecology, D&R Institute of Hygiene, Microbiology and Environmental Medicine, Medical University of Graz, 8010 Graz, Austria
| | - Birgit Kogler
- Department for Water-Hygiene and Micro-Ecology, D&R Institute of Hygiene, Microbiology and Environmental Medicine, Medical University of Graz, 8010 Graz, Austria
| | | | - Michael Gehrer
- Styrian Hospital Corporation KAGes, Hospital Leoben, 8700 Leoben, Austria
| | - Franz F. Reinthaler
- Department for Water-Hygiene and Micro-Ecology, D&R Institute of Hygiene, Microbiology and Environmental Medicine, Medical University of Graz, 8010 Graz, Austria
| |
Collapse
|
16
|
Entezari S, Al MA, Mostashari A, Ganjidoust H, Ayati B, Yang J. Microplastics in urban waters and its effects on microbial communities: a critical review. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:88410-88431. [PMID: 36327084 DOI: 10.1007/s11356-022-23810-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 10/20/2022] [Indexed: 06/16/2023]
Abstract
Microplastic (MP) pollution is one of the emerging threats to the water and terrestrial environment, forcing a new environmental challenge due to the growing trend of plastic released into the environment. Synthetic and non-synthetic plastic components can be found in rivers, lakes/reservoirs, oceans, mountains, and even remote areas, such as the Arctic and Antarctic ice sheets. MPs' main challenge is identifying, measuring, and evaluating their impacts on environmental behaviors, such as carbon and nutrient cycles, water and wastewater microbiome, and the associated side effects. However, until now, no standardized methodical protocols have been proposed for comparing the results of studies in different environments, especially in urban water and wastewater. This review briefly discusses MPs' sources, fate, and transport in urban waters and explains methodological uncertainty. The effects of MPs on urban water microbiomes, including urban runoff, sewage wastewater, stagnant water in plumbing networks, etc., are also examined in depth. Furthermore, this study highlights the pathway of MPs and their transport vectors to different parts of ecosystems and human life, particularly through mediating microbial communities, antibiotic-resistant genes, and biogeochemical cycles. Overall, we have briefly highlighted the present research gaps, the lack of appropriate policy for evaluating microplastics and their interactions with urban water microbiomes, and possible future initiatives.
Collapse
Affiliation(s)
- Saber Entezari
- Environmental Engineering Division, Faculty of Civil & Env. Eng., TMU, Tehran, Iran
| | - Mamun Abdullah Al
- Aquatic Eco-Health Group, Fujian Key Laboratory of Watershed Ecology, Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, 1799 Jimei Road, Xiamen, 361021, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Amir Mostashari
- Environmental Engineering Division, Faculty of Civil & Env. Eng., TMU, Tehran, Iran
| | - Hossein Ganjidoust
- Environmental Engineering Division, Faculty of Civil & Env. Eng., TMU, Tehran, Iran.
| | - Bita Ayati
- Environmental Engineering Division, Faculty of Civil & Env. Eng., TMU, Tehran, Iran
| | - Jun Yang
- Aquatic Eco-Health Group, Fujian Key Laboratory of Watershed Ecology, Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, 1799 Jimei Road, Xiamen, 361021, China
| |
Collapse
|
17
|
Mechanism of Biofilm Formation on Installation Materials and Its Impact on the Quality of Tap Water. WATER 2022. [DOI: 10.3390/w14152401] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
In the conducted study, an attempt was made to verify and evaluate the impact of the biofilm formed on the surfaces of the installation material on the quality and sanitary safety of tap water reaching the consumer. For biofilm studies, fractal analysis and quantitative bacteriological analysis were used. The quality of tap water flowing through the experimental installation (semi-technical scale) was determined using physicochemical and microbiological parameters. The quantitative analysis of the biofilm showed that an increase in the number of microorganisms was observed in the initial phase of biofilm formation (reached 1.4 × 104 CFU/mL/cm2 on day 14). During this period, there was a chaotic build-up of bacterial cells, as evidenced by an increase in the roughness of the profile lines. Unstable elevations of the biofilm formed in this way could be easily detached from the structure of the material, which resulted in deterioration of the bacteriological quality of the water leaving the installation. The obtained results indicate that the biofilm completely and permanently covered the surface of the tested material after 25 days of testing (the surface roughness described by the fractal dimension decreased). Moreover, the favorable temperature (22.6 °C) and the recorded decrease in the content of inorganic nitrogen (by 15%), phosphorus (by 14%), and dissolved oxygen (by 15%) confirm the activity of microorganisms. The favorable environmental conditions in the installation (the presence of nutrients, low chlorine concentration, and high temperature) contributed to the secondary development of microorganisms, including pathogenic organisms in the tested waters.
Collapse
|
18
|
Rahmatika I, Kurisu F, Furumai H, Kasuga I. Dynamics of the Microbial Community and Opportunistic Pathogens after Water Stagnation in the Premise Plumbing of a Building. Microbes Environ 2022; 37. [PMID: 35321996 PMCID: PMC8958293 DOI: 10.1264/jsme2.me21065] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
In premise plumbing, microbial water quality may deteriorate under certain conditions, such as stagnation. Stagnation results in a loss of disinfectant residual, which may lead to the regrowth of microorganisms, including opportunistic pathogens. In the present study, microbial regrowth was investigated at eight faucets in a building over four seasons in one year. Water samples were obtained before and after 24 h of stagnation. In the first 100 mL after stagnation, total cell counts measured by flow cytometry increased 14- to 220-fold with a simultaneous decrease in free chlorine from 0.17–0.36 mg L–1 to <0.02 mg L–1. After stagnation, total cell counts were not significantly different among seasons; however, the composition of the microbial community varied seasonally. The relative abundance of Pseudomonas spp. was dominant in winter, whereas Sphingomonas spp. were dominant in most faucets after stagnation in other seasons. Opportunistic pathogens, such as Legionella pneumophila, Mycobacterium avium, Pseudomonas aeruginosa, and Acanthamoeba spp., were below the quantification limit for real-time quantitative PCR in all samples. However, sequences related to other opportunistic pathogens, including L. feeleii, L. maceachernii, L. micdadei, M. paragordonae, M. gordonae, and M. haemophilum, were detected. These results indicate that health risks may increase after stagnation due to the regrowth of opportunistic pathogens.
Collapse
Affiliation(s)
- Iftita Rahmatika
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo
| | - Futoshi Kurisu
- Research Center for Water Environment Technology, Graduate School of Engineering, The University of Tokyo
| | - Hiroaki Furumai
- Research Center for Water Environment Technology, Graduate School of Engineering, The University of Tokyo
| | - Ikuro Kasuga
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo
| |
Collapse
|
19
|
Farhat N, Kim L, Mineta K, Alarawi M, Gojobori T, Saikaly P, Vrouwenvelder J. Seawater desalination based drinking water: Microbial characterization during distribution with and without residual chlorine. WATER RESEARCH 2022; 210:117975. [PMID: 34952456 DOI: 10.1016/j.watres.2021.117975] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 12/12/2021] [Accepted: 12/14/2021] [Indexed: 06/14/2023]
Abstract
Monitoring the changes that occur to water during distribution is vital to ensure water safety. In this study, the biological stability of reverse osmosis (RO) produced drinking water, characterized by low cell concentration and low assimilable organic carbon, in combination with chlorine disinfection was investigated. Water quality at several locations throughout the existing distribution network was monitored to investigate whether microbial water quality changes can be identified. Results revealed that the water leaving the plant had an average bacterial cell concentration of 103 cells/mL. A 0.5-1.5 log increase in bacterial cell concentration was observed at locations in the network. The residual disinfectant was largely dissipated in the network from 0.5 mg/L at the treatment plant to less than 0.1 mg/L in the network locations. The simulative study involving miniature distribution networks, mimicking the dynamics of a distribution network, fed with the RO produced chlorinated and non-chlorinated drinking water revealed that distributing RO produced water without residual disinfection, especially at high water temperatures (25-30 °C), poses a higher chance for water quality change. Within six months of operation of the miniature network fed with unchlorinated RO produced water, the adenosine triphosphate (ATP) and total cell concentration (TCC) in the pipe biofilm were 4 × 102 pg ATP/cm2 and 1 × 107 cells/ cm2. The low bacterial cell concentration and organic carbon concentration in the RO-produced water did not prevent biofilm development inside the network with and without residual chlorine. The bacterial community analysis using 16S ribosomal RNA (rRNA) gene sequencing revealed that mesophilic bacteria with higher temperature tolerance and bacteria associated with oligotrophic, nutrient-poor conditions dominated the biofilm, with no indication of the existence of opportunistic pathogenic species. However, chlorination selected against most bacterial groups and the bacterial community that remained was mainly the bacteria capable of surviving disinfection regimes. Biofilms that developed in the presence of chlorine contained species classified as opportunistic pathogens. These biofilms have an impact on shaping the water quality received at the consumer tap. The presence of these bacteria on its own is not a health risk indicator; viability assessment and qPCRs targeting genes specific to the opportunistic pathogens as well as quantitative microbiological risk assessment (QMRA) should be included to assess the risk. The results from this study highlight the importance of implementing multiple barriers to ensure water safety. Changes in water quality detected even when high-quality disinfected RO-produced water is distributed highlight microbiological challenges that chlorinated systems endure, especially at high water temperatures.
Collapse
Affiliation(s)
- Nadia Farhat
- Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia.
| | - Lanhee Kim
- Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Katsuhiko Mineta
- Computational Bioscience Research Center (CBRC), Division of Computer, Electrical and Mathematical Sciences and Engineering (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Mohammed Alarawi
- Computational Bioscience Research Center (CBRC), Division of Computer, Electrical and Mathematical Sciences and Engineering (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Takashi Gojobori
- Computational Bioscience Research Center (CBRC), Division of Computer, Electrical and Mathematical Sciences and Engineering (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia; Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Pascal Saikaly
- Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Johannes Vrouwenvelder
- Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia; Faculty of Applied Sciences, Department of Biotechnology, Delft University of Technology, Van der Maasweg 9, Delft 2629 HZ, Netherlands
| |
Collapse
|
20
|
Liang J, Swanson CS, Wang L, He Q. Impact of building closures during the COVID-19 pandemic on Legionella infection risks. Am J Infect Control 2021; 49:1564-1566. [PMID: 34537274 PMCID: PMC8447490 DOI: 10.1016/j.ajic.2021.09.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 08/11/2021] [Accepted: 09/10/2021] [Indexed: 01/14/2023]
Abstract
Prolonged building closures are prevalent during the COVID-19 pandemic, resulting in extreme stagnation in building water systems. High-throughput sequencing analysis revealed significantly increased presence of Legionella due to extreme water stagnation, highlighting elevated exposure risks to Legionella from building water systems during re-opening of previously closed buildings.
Collapse
Affiliation(s)
- Jiayu Liang
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, Jiangsu, China
| | - Clifford S Swanson
- Department of Civil and Environmental Engineering, The University of Tennessee, Knoxville, TN, USA
| | - Liang Wang
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, Jiangsu, China.
| | - Qiang He
- Department of Civil and Environmental Engineering, The University of Tennessee, Knoxville, TN, USA.
| |
Collapse
|
21
|
Hess A, Baum C, Schiessl K, Besmer MD, Hammes F, Morgenroth E. Stagnation leads to short-term fluctuations in the effluent water quality of biofilters: A problem for greywater reuse? WATER RESEARCH X 2021; 13:100120. [PMID: 34647001 PMCID: PMC8495163 DOI: 10.1016/j.wroa.2021.100120] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 09/06/2021] [Accepted: 09/11/2021] [Indexed: 05/04/2023]
Abstract
A key characteristic of decentralized greywater treatment and reuse is high variability in both nutrient concentrations and flow. This variability in flow leads to stagnant water in the system and causes short-term fluctuations in the effluent water quality. Automated monitoring tools provide data to understand the mechanisms underlying the dynamics and to adapt control strategies accordingly. We investigated the fluctuations in a building-scale greywater treatment system comprising a membrane bioreactor followed by a biological activated carbon filter. Short-term dynamics in the effluent of the biological activated carbon filter were monitored with automated flow cytometry and turbidity, and the impact of these fluctuations on various hygiene-relevant parameters in the reuse water was evaluated. Continuous biofilm detachment into the stagnant water in the biological activated carbon filter led to temporarily increased turbidity and cell concentrations in the effluent after periods of stagnation. The fluctuations in cell concentrations were consistent with a model assuming higher detachment rates during flow than during times with stagnant water. For this system, total cell concentration and turbidity were strongly correlated. We also showed that the observed increase in cell concentration was not related to either an increase of organic carbon concentration or the concentration of two opportunistic pathogens, P. aeruginosa and L. pneumophila. Our findings demonstrate that turbidity measurements are sensitive to changes in the effluent water quality and can be used to monitor the fluctuations caused by intermittent flow. Intermittent flow did not lead to an increase in opportunistic pathogens, and this study provides no indications that stagnant water in biological activated carbon filters need be prevented.
Collapse
Affiliation(s)
- Angelika Hess
- Eawag: Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland
- ETH Zürich, Institute of Environmental Engineering, 8093 Zürich, Switzerland
| | - Chiara Baum
- Eawag: Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland
| | | | | | - Frederik Hammes
- Eawag: Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland
| | - Eberhard Morgenroth
- Eawag: Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland
- ETH Zürich, Institute of Environmental Engineering, 8093 Zürich, Switzerland
- Corresponding author.
| |
Collapse
|
22
|
Richard R, Boyer TH. Pre- and post-flushing of three schools in Arizona due to COVID-19 shutdown. AWWA WATER SCIENCE 2021; 3:e1239. [PMID: 34901766 PMCID: PMC8646703 DOI: 10.1002/aws2.1239] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 08/03/2021] [Accepted: 08/11/2021] [Indexed: 01/14/2023]
Abstract
A one-day water sampling and flushing study was conducted for three schools in Maricopa County that experienced prolonged building inactivity due to the COVID-19 pandemic: an elementary school, middle school, and high school. Grab samples were taken at hand washing sinks, water fountains, and hose bibbs before and after flushing. Samples were analyzed for free chlorine, UVA254, copper, lead, total trihalomethanes, pH, conductivity, temperature, and Legionella species. All three schools experienced an increase in free chlorine post-flush. Copper concentrations were higher for first draw samples than post-flush samples for all schools. Conductivity, temperature, and pH did not see a major change after flushing. UVA254 values decreased after flushing. Bromoform species saw a 20% increase after flushing at the elementary school. Legionella spp. did not decrease post-flush at the elementary school. Overall, flushing changed the water quality at the schools. However, equipment flushing may be necessary to fully remediate Legionella spp. ARTICLE IMPACT STATEMENT Prolonged closure of buildings causes water quality issues such as lack of disinfectant and Legionella. Flushing can restore water quality.
Collapse
Affiliation(s)
- Rain Richard
- School of Sustainable Engineering and the Built Environment (SSEBE)Arizona State UniversityTempeArizonaUSA
- Biodesign Swette Center for Environmental BiotechnologyArizona State UniversityTempeArizonaUSA
| | - Treavor H. Boyer
- School of Sustainable Engineering and the Built Environment (SSEBE)Arizona State UniversityTempeArizonaUSA
- Biodesign Swette Center for Environmental BiotechnologyArizona State UniversityTempeArizonaUSA
| |
Collapse
|
23
|
Benoit MÈ, Prévost M, Succar A, Charron D, Déziel E, Robert E, Bédard E. Faucet aerator design influences aerosol size distribution and microbial contamination level. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 775:145690. [PMID: 33631571 DOI: 10.1016/j.scitotenv.2021.145690] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 02/03/2021] [Accepted: 02/03/2021] [Indexed: 06/12/2023]
Abstract
Faucet aerators have been linked to multiple opportunistic pathogen outbreaks in hospital, especially Pseudomonas aeruginosa, their complex structure promoting biofilm development. The importance of bacteria aerosolization by faucet aerators and their incidence on the risk of infection remain to be established. In this study, ten different types of aerators varying in complexity, flow rates and type of flow were evaluated in a controlled experimental setup to determine the production of aerosols and the level of contamination. The aerosol particle number density and size distribution were assessed using a particle spectrometer. The bacterial load was quantified with a 14-stage cascade impactor, where aerosol particles were captured and separated by size, then analysed by culture and flow cytometry. The water was seeded with Pseudomonas fluorescens as a bacterial indicator. Aerosol particle size and mean mass distribution varied depending on the aerator model. Devices without aeration or with laminar flow produced the lowest number and mass of aerosol particles when measured with spectrometry. Models with aeration displayed wide differences in their potential production of aerosol particles. A new aerator with a low flow, no air inlet in its structure, and a spray stream produced 12 to 395 times fewer aerosol particles containing bacteria. However, the impact of low flow on biofilm development and incorporation of pathogens should be further investigated. Repeated use of aerators resulted in fouling which increased the quantity of bacteria released through aerosol particles. An in-depth mechanical cleaning including complete dismantling of the aerator was required to recover initial performances. Aerators should be selected to minimize aerosol production, considering the ease of maintenance and the main water usage at each sink. Low flow aerators produced a lower number of contaminated aerosol particles when new but may be more susceptible to fouling and quickly lose their initial advantage.
Collapse
Affiliation(s)
- Marie-Ève Benoit
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC, Canada
| | - Michèle Prévost
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC, Canada
| | - Antonella Succar
- Department of Mechanical Engineering, Polytechnique Montréal, Montréal, QC, Canada
| | - Dominique Charron
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC, Canada
| | - Eric Déziel
- Centre Armand-Frappier Santé Biotechnologie, Institut National de la Recherche Scientifique (INRS), Laval, QC, Canada
| | - Etienne Robert
- Department of Mechanical Engineering, Polytechnique Montréal, Montréal, QC, Canada
| | - Emilie Bédard
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC, Canada.
| |
Collapse
|
24
|
Yu Y, Chen X, Wang Y, Mao J, Ding Z, Lu Y, Wang X, Lian X, Shi Y. Producing and storing self-sustaining drinking water from rainwater for emergency response on isolated island. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 768:144513. [PMID: 33453540 DOI: 10.1016/j.scitotenv.2020.144513] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 12/10/2020] [Accepted: 12/11/2020] [Indexed: 06/12/2023]
Abstract
Drinking water on isolated islands includes treated rainwater, water shipped from the mainland, and desalinated seawater. However, marine transportation and desalination plants are vulnerable to emergencies, such as extreme weather, making self-sustaining stand-by water for emergency response essential. Rainwater is ideal for producing the stand-by water, and rainwater harvesting is sustainable and clean, and prolonged biostability can be ensured by managing biological and chemical parameters. The present study applied a stand-by drinking water purification system (primarily including nanofiltration and low-dose chlorination) to explore the feasibility of producing and storing cleaner drinking water from rainwater and the following conclusions were drawn. First, treatment of rainwaters ensures biosafety for seven days, which is longer than that for untreated rainwater; the proportion of opportunistic pathogens decreased from 23.40-7.77% after nanofiltration, and it was proposed that the microbial community converges after advanced water treatment. Second, chemical qualities were improved. Local resource coral sand prevents pH in rainwater from decreasing below 6.5, and treated rainwater had lower disinfection by-product potential and higher disinfection efficiency, allowing periodical rainwater recycling. Third, harvesting rainwater was extremely cost-effective, with an operation cost of 1.5-2.5 RMB/m3. From biosafety, chemical safety, and economic cost perspectives, self-sustaining water from rainwater can contributes to the development of sustainable and cost-effective water supply systems on isolated islands. Mixing treated rainwater and desalinated seawater reasonably guarantees sufficiency and safety.
Collapse
Affiliation(s)
- Yingjun Yu
- College of Defense Engineering, Peoples' Liberation Army Engineering University, Nanjing 210007, China
| | - Xiao Chen
- College of Defense Engineering, Peoples' Liberation Army Engineering University, Nanjing 210007, China
| | - Yi Wang
- College of Defense Engineering, Peoples' Liberation Army Engineering University, Nanjing 210007, China.
| | - Jinfeng Mao
- College of Defense Engineering, Peoples' Liberation Army Engineering University, Nanjing 210007, China.
| | - Zhibin Ding
- College of Defense Engineering, Peoples' Liberation Army Engineering University, Nanjing 210007, China
| | - Yaofeng Lu
- College of Defense Engineering, Peoples' Liberation Army Engineering University, Nanjing 210007, China
| | - Xiuchun Wang
- College of Defense Engineering, Peoples' Liberation Army Engineering University, Nanjing 210007, China
| | - Xiaoying Lian
- College of Defense Engineering, Peoples' Liberation Army Engineering University, Nanjing 210007, China
| | - Yue Shi
- College of Defense Engineering, Peoples' Liberation Army Engineering University, Nanjing 210007, China
| |
Collapse
|
25
|
Hozalski RM, LaPara TM, Zhao X, Kim T, Waak MB, Burch T, McCarty M. Flushing of Stagnant Premise Water Systems after the COVID-19 Shutdown Can Reduce Infection Risk by Legionella and Mycobacterium spp. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:15914-15924. [PMID: 33232602 DOI: 10.1021/acs.est.0c06357] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
There is concern about potential exposure to opportunistic pathogens when reopening buildings closed due to the COVID-19 pandemic. In this study, water samples were collected before, during, and after flushing showers in five unoccupied (i.e., for ∼2 months) university buildings with quantification of opportunists via a cultivation-based assay (Legionella pneumophila only) and quantitative PCR. L. pneumophila were not detected by either method; Legionella spp., nontuberculous mycobacteria (NTM), and Mycobacterium avium complex (MAC), however, were widespread. Using quantitative microbial risk assessment (QMRA), the estimated risks of illness from exposure to L. pneumophila and MAC via showering were generally low (i.e., less than a 10-7 daily risk threshold), with the exception of systemic infection risk from MAC exposure in some buildings. Flushing rapidly restored the total chlorine (as chloramine) residual and decreased bacterial gene targets to building inlet concentrations within 30 min. During the postflush stagnation period, the residual chlorine dissipated within a few days and bacteria rebounded, approaching preflush concentrations after 6-7 days. These results suggest that flushing can quickly improve water quality in unoccupied buildings, but the improvement may only last a few days.
Collapse
Affiliation(s)
- Raymond M Hozalski
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, Minneapolis 55455, Minnesota, United States
| | - Timothy M LaPara
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, Minneapolis 55455, Minnesota, United States
| | - Xiaotian Zhao
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, Minneapolis 55455, Minnesota, United States
| | - Taegyu Kim
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, Minneapolis 55455, Minnesota, United States
| | - Michael B Waak
- Norwegian University of Science and Technology, Trondheim 7031, Norway
- Department of Infrastructure, SINTEF Community, Trondheim 7031, Norway
| | - Tucker Burch
- Agricultural Research Service, U.S. Department of Agriculture, Marshfield, Wisconsin 54449, United States
| | - Michael McCarty
- School of Public Health, University of Minnesota, Minneapolis 55455, Minnesota, United States
| |
Collapse
|
26
|
Assessing the Food Safety Risk Posed by Birds Entering Leafy Greens Fields in the US Southwest. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17238711. [PMID: 33255193 PMCID: PMC7727694 DOI: 10.3390/ijerph17238711] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 11/17/2020] [Accepted: 11/18/2020] [Indexed: 12/18/2022]
Abstract
In the US Southwest, it is common to observe birds in leafy green fields, though the risk they contribute to foodborne outbreaks remains unclear. In this study, we investigated and recorded the relationship between birds near leafy green fields and the risk for contaminated irrigation water or leafy green plants. We monitored the presence of birds for over two years and performed cloacal swab analysis for non-pathogenic Escherichia coli, E. coli O157:H7 and Salmonellaenterica, while also monitoring the incidence of other microbial indicators. We also assessed the risks from bird feces by performing observations in a commercial field reported with Salmonella positive samples and by analyzing the survival of foodborne pathogens in bird feces. Our results showed that most of the birds near the crop fields were resident small birds. We did not observe a correlation between the number of birds in sites and the incidence of indicator bacteria (e.g., coliforms, E. coli) in irrigation canal water, with the exception of one out of four sites where water flow was low or stagnant. Using walk-in-traps, 305 birds were captured and placed in short-term captivity to determine the presence of various bacteria. None of the birds tested positive for E. coli O157:H7 or Salmonella. However, nearly 40% of the birds captured were confirmed positive for non-pathogenic E. coli. We found no correlation between age (young, adult, unknown), gender (male, female, unknown) and the incidence of E. coli positive birds, but we observed significantly higher probability of incidence during October-December. The role of relative humidity and temperature on bacterial survival appeared to play a key role in the survival of Salmonella on the leaves of spinach plants in a commercial field. This was also confirmed in laboratory conditions where Salmonella inoculated in bird feces and exposed to 15 °C and 80% RH(Relative humidity) survived beyond 133 days, while at 26 °C and 40% RH, the organism was undetectable after 63 days. Our results suggest that local birds associated with leafy green fields likely pose a minimal impact of risk for food contamination, but also points out the need for increased analysis specifically for E. coli O157:H7. Furthermore, our study suggests the need for expanding research that addresses risks associated with large migratory birds, especially in areas where stagnated water sources would be used for overhead sprinkle irrigation.
Collapse
|
27
|
Hirsh MB, Baron JL, Mietzner SM, Rihs JD, Yassin MH, Stout JE. Evaluation of Recommended Water Sample Collection Methods and the Impact of Holding Time on Legionella Recovery and Variability from Healthcare Building Water Systems. Microorganisms 2020; 8:E1770. [PMID: 33187132 PMCID: PMC7696883 DOI: 10.3390/microorganisms8111770] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 11/07/2020] [Accepted: 11/09/2020] [Indexed: 12/03/2022] Open
Abstract
Water safety and management programs (WSMP) utilize field measurements to evaluate control limits and monitor water quality parameters including Legionella presence. This monitoring is important to verify that the plan is being implemented properly. However, once it has been determined when and how to sample for Legionella, it is important to choose appropriate collection and processing methods. We sought to compare processing immediate and flushed samples, filtration of different volumes collected, and sample hold times. Hot water samples were collected immediately and after a 2-min flush. These samples were plated directly and after filtration of either 100 mL, 200 mL, or 1 L. Additionally, unflushed samples were collected and processed immediately and after 1, 24, and 48 h of hold time. We found that flushed samples had significant reductions in Legionella counts compared to immediate samples. Processing 100 mL of that immediate sample both directly and after filter concentration yielded the highest concentration and percent sample positivity, respectively. We also show that there was no difference in culture values from time 0 compared to hold times of 1 h and 24 h. At 48 h, there were slightly fewer Legionella recovered than at time 0. However, Legionella counts were so variable based on sampling location and date that this hold time effect was minimal. The interpretation of Legionella culture results depends on the sample collection and processing methods used, as these can have a huge impact on the success of sampling and the validation of control measures.
Collapse
Affiliation(s)
- Marisa B. Hirsh
- Special Pathogens Laboratory, Pittsburgh, PA 15219, USA; (M.B.H.); (J.L.B.); (S.M.M.); (J.D.R.)
| | - Julianne L. Baron
- Special Pathogens Laboratory, Pittsburgh, PA 15219, USA; (M.B.H.); (J.L.B.); (S.M.M.); (J.D.R.)
| | - Sue M. Mietzner
- Special Pathogens Laboratory, Pittsburgh, PA 15219, USA; (M.B.H.); (J.L.B.); (S.M.M.); (J.D.R.)
| | - John D. Rihs
- Special Pathogens Laboratory, Pittsburgh, PA 15219, USA; (M.B.H.); (J.L.B.); (S.M.M.); (J.D.R.)
| | - Mohamed H. Yassin
- Department of Infection Control, UPMC Mercy Hospital, Pittsburgh, PA 15219, USA;
| | - Janet E. Stout
- Special Pathogens Laboratory, Pittsburgh, PA 15219, USA; (M.B.H.); (J.L.B.); (S.M.M.); (J.D.R.)
- Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, PA 15261, USA
| |
Collapse
|
28
|
Hutchins CF, Moore G, Webb J, Walker JT. Investigating alternative materials to EPDM for automatic taps in the context of Pseudomonas aeruginosa and biofilm control. J Hosp Infect 2020; 106:429-435. [PMID: 32946923 DOI: 10.1016/j.jhin.2020.09.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Accepted: 09/10/2020] [Indexed: 11/24/2022]
Abstract
BACKGROUND Automatic taps use solenoid valves (SVs) which incorporate a rubber (typically EPDM) diaphragm to control water flow. Contaminated SVs can be reservoirs of opportunistic pathogens such as Pseudomonas aeruginosa; an important cause of healthcare-associated infection. AIMS To investigate the attachment and biofilm formation of P. aeruginosa on EPDM and relevant alternative rubbers to assess the impact on water hygiene in a laboratory model. METHODS Biofilm formation on EPDM, silicone and nitrile rubber coupons was investigated using a CDC biofilm reactor. SVs incorporating EPDM or nitrile rubber diaphragms were installed on to an experimental water distribution system (EWDS) and inoculated with P. aeruginosa. P. aeruginosa water levels were monitored for 12-weeks. SVs incorporating diaphragms (EPDM, silicone or silver ion-impregnated silicone rubber), pre-colonized with P. aeruginosa, were installed and the effect of flushing as a control measure was investigated. The concentration of P. aeruginosa in the water was assessed by culture and biofilm assessed by culture and microscopy. FINDINGS Bacterial attachment was significantly higher on nitrile (6.2 × 105 cfu/coupon) and silicone (5.4 × 105 cfu/coupon) rubber than on EPDM (2.9 ×105 cfu/coupon) (P<0.05, N = 17). Results obtained in vitro did not translate to the EWDS where, after 12-weeks in situ, there was no significant difference in P. aeruginosa water levels or biofilm levels. Flushing caused a superficial reduction in bacterial counts after <5 min of stagnation. CONCLUSION This study did not provide evidence to support replacement of EPDM with (currently available) alternative rubbers and indicated the first sample of water dispensed from a tap should be avoided for use in healthcare settings.
Collapse
Affiliation(s)
- C F Hutchins
- Public Health England, Porton Down, Salisbury, Wiltshire, UK; University of Southampton, Southampton, Hampshire, UK.
| | - G Moore
- Public Health England, Porton Down, Salisbury, Wiltshire, UK
| | - J Webb
- University of Southampton, Southampton, Hampshire, UK
| | - J T Walker
- Public Health England, Porton Down, Salisbury, Wiltshire, UK
| |
Collapse
|
29
|
The impact of metal pipe materials, corrosion products, and corrosion inhibitors on antibiotic resistance in drinking water distribution systems. Appl Microbiol Biotechnol 2020; 104:7673-7688. [DOI: 10.1007/s00253-020-10777-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 06/29/2020] [Accepted: 07/05/2020] [Indexed: 02/07/2023]
|
30
|
Buse HY, Morris BJ, Gomez-Alvarez V, Szabo JG, Hall JS. Legionella Diversity and Spatiotemporal Variation in The Occurrence of Opportunistic Pathogens within a Large Building Water System. Pathogens 2020; 9:E567. [PMID: 32668779 PMCID: PMC7400177 DOI: 10.3390/pathogens9070567] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 07/06/2020] [Accepted: 07/07/2020] [Indexed: 01/22/2023] Open
Abstract
Understanding Legionella survival mechanisms within building water systems (BWSs) is challenging due to varying engineering, operational, and water quality characteristics unique to each system. This study aimed to evaluate Legionella, mycobacteria, and free-living amoebae occurrence within a BWS over 18-28 months at six locations differing in plumbing material and potable water age, quality, and usage. A total of 114 bulk water and 57 biofilm samples were analyzed. Legionella culturability fluctuated seasonally with most culture-positive samples being collected during the winter compared to the spring, summer, and fall months. Positive and negative correlations between Legionella and L. pneumophila occurrence and other physiochemical and microbial water quality parameters varied between location and sample types. Whole genome sequencing of 19 presumptive Legionella isolates, from four locations across three time points, identified nine isolates as L. pneumophila serogroup (sg) 1 sequence-type (ST) 1; three as L. pneumophila sg5 ST1950 and ST2037; six as L. feeleii; and one as Ochrobactrum. Results showed the presence of a diverse Legionella population with consistent and sporadic occurrence at four and two locations, respectively. Viewed collectively with similar studies, this information will enable a better understanding of the engineering, operational, and water quality parameters supporting Legionella growth within BWSs.
Collapse
Affiliation(s)
- Helen Y. Buse
- Homeland Security and Materials Management Division, Center for Environmental Solutions & Emergency Response (CESER), Office of Research and Development (ORD), US Environmental Protection Agency (USEPA), Cincinnati, OH 45268, USA; (J.G.S.); (J.S.H.)
| | - Brian J. Morris
- Pegasus Technical Services, Inc c/o US EPA, Cincinnati, OH 45268, USA;
| | - Vicente Gomez-Alvarez
- Water Infrastructure Division, Center for Environmental Solutions & Emergency Response (CESER), US Environmental Protection Agency (USEPA), Office of Research and Development (ORD), Cincinnati, OH 45268, USA;
| | - Jeffrey G. Szabo
- Homeland Security and Materials Management Division, Center for Environmental Solutions & Emergency Response (CESER), Office of Research and Development (ORD), US Environmental Protection Agency (USEPA), Cincinnati, OH 45268, USA; (J.G.S.); (J.S.H.)
| | - John S. Hall
- Homeland Security and Materials Management Division, Center for Environmental Solutions & Emergency Response (CESER), Office of Research and Development (ORD), US Environmental Protection Agency (USEPA), Cincinnati, OH 45268, USA; (J.G.S.); (J.S.H.)
| |
Collapse
|
31
|
Proctor CR, Rhoads WJ, Keane T, Salehi M, Hamilton K, Pieper KJ, Cwiertny DM, Prévost M, Whelton AJ. Considerations for large building water quality after extended stagnation. AWWA WATER SCIENCE 2020; 2:e1186. [PMID: 32838226 DOI: 10.31219/osf.io/qvj3b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 06/03/2020] [Accepted: 06/09/2020] [Indexed: 05/25/2023]
Abstract
The unprecedented number of building closures related to the coronavirus disease (COVID-19) pandemic is concerning because water stagnation will occur in many buildings that do not have water management plans in place. Stagnant water can have chemical and microbiological contaminants that pose potential health risks to occupants. Health officials, building owners, utilities, and other entities are rapidly developing guidance to address this issue, but the scope, applicability, and details included in the guidance vary widely. To provide a primer of large building water system preventative and remedial strategies, peer-reviewed, government, industry, and nonprofit literature relevant to water stagnation and decontamination practices for plumbing was synthesized. Preventative practices to help avoid the need for recommissioning (e.g., routine flushing) and specific actions, challenges, and limitations associated with recommissioning were identified and characterized. Considerations for worker and occupant safety were also indicated. The intended audience of this work includes organizations developing guidance.
Collapse
Affiliation(s)
- Caitlin R Proctor
- Division of Environmental and Ecological Engineering, Lyles School of Civil Engineering, Weldon School of Biomedical Engineering, School of Materials Engineering Purdue University West Lafayette Indiana
| | - William J Rhoads
- Department of Civil and Environmental Engineering Virginia Tech Blacksburg Virginia
| | - Tim Keane
- Legionella Risk Management, Inc. Chalfont Pennsylvania
| | - Maryam Salehi
- Department of Civil Engineering University of Memphis Memphis Tennessee
| | - Kerry Hamilton
- School of Sustainable Engineering and the Built Environment Arizona State University Tempe Arizona
| | - Kelsey J Pieper
- Department of Civil and Environmental Engineering Northeastern University Boston Massachusetts
| | - David M Cwiertny
- Department of Civil and Environmental Engineering, Seamans Center for the Engineering Arts and Sciences University of Iowa Iowa City Iowa
- Center for Health Effects of Environmental Contamination University of Iowa Iowa City Iowa
- Public Policy Center University of Iowa Iowa City Iowa
| | - Michele Prévost
- Civil, Geological and Mining Engineering Polytechnique Montreal Montréal Québec Canada
| | - Andrew J Whelton
- Lyles School of Civil Engineering, Division of Environmental and Ecological Engineering Purdue University West Lafayette Indiana
| |
Collapse
|
32
|
Feeding the Building Plumbing Microbiome: The Importance of Synthetic Polymeric Materials for Biofilm Formation and Management. WATER 2020. [DOI: 10.3390/w12061774] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
The environmental conditions in building plumbing systems differ considerably from the larger distribution system and, as a consequence, uncontrolled changes in the drinking water microbiome through selective growth can occur. In this regard, synthetic polymeric plumbing materials are of particular relevance, since they leach assimilable organic carbon that can be utilized for bacterial growth. Here, we discuss the complexity of building plumbing in relation to microbial ecology, especially in the context of low-quality synthetic polymeric materials (i.e., plastics) and highlight the major knowledge gaps in the field. We furthermore show how knowledge on the interaction between material properties (e.g., carbon migration) and microbiology (e.g., growth rate) allows for the quantification of initial biofilm development in buildings. Hence, research towards a comprehensive understanding of these processes and interactions will enable the implementation of knowledge-based management strategies. We argue that the exclusive use of high-quality materials in new building plumbing systems poses a straightforward strategy towards managing the building plumbing microbiome. This can be achieved through comprehensive material testing and knowledge sharing between all stakeholders including architects, planners, plumbers, material producers, home owners, and scientists.
Collapse
|
33
|
Proctor CR, Rhoads WJ, Keane T, Salehi M, Hamilton K, Pieper KJ, Cwiertny DM, Prévost M, Whelton AJ. Considerations for Large Building Water Quality after Extended Stagnation. ACTA ACUST UNITED AC 2020; 2:e1186. [PMID: 32838226 PMCID: PMC7323006 DOI: 10.1002/aws2.1186] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 06/03/2020] [Accepted: 06/09/2020] [Indexed: 01/04/2023]
Abstract
The unprecedented number of building closures related to the coronavirus disease (COVID‐19) pandemic is concerning because water stagnation will occur in many buildings that do not have water management plans in place. Stagnant water can have chemical and microbiological contaminants that pose potential health risks to occupants. Health officials, building owners, utilities, and other entities are rapidly developing guidance to address this issue, but the scope, applicability, and details included in the guidance vary widely. To provide a primer of large building water system preventative and remedial strategies, peer‐reviewed, government, industry, and nonprofit literature relevant to water stagnation and decontamination practices for plumbing was synthesized. Preventative practices to help avoid the need for recommissioning (e.g., routine flushing) and specific actions, challenges, and limitations associated with recommissioning were identified and characterized. Considerations for worker and occupant safety were also indicated. The intended audience of this work includes organizations developing guidance.
Collapse
Affiliation(s)
- Caitlin R Proctor
- Division of Environmental and Ecological Engineering, Lyles School of Civil Engineering, Weldon School of Biomedical Engineering, School of Materials Engineering Purdue University West Lafayette IN
| | - William J Rhoads
- Department of Civil and Environmental Engineering Virginia Tech Blacksburg VA
| | - Tim Keane
- Consulting Engineer, Legionella Risk Management, Inc PA
| | - Maryam Salehi
- Department of Civil Engineering University of Memphis Memphis TN
| | - Kerry Hamilton
- School of Sustainable Engineering and the Built Environment Arizona State University Tempe AZ
| | - Kelsey J Pieper
- Department of Civil and Environmental Engineering Northeastern University Boston MA
| | - David M Cwiertny
- Department of Civil & Environmental Engineering, 4105 Seamans Center for the Engineering Arts and Sciences University of Iowa Iowa City IA.,Center for Health Effects of Environmental Contamination, 251 North Capitol Street, Chemistry Building - Room W195 University of Iowa Iowa City IA.,Public Policy Center, 310 South Grand Ave, 209 South Quadrangle University of Iowa Iowa City IA
| | - Michele Prévost
- Professor and Principal Chairholder, NSERC Industrial Chair on Drinking Water, Civil, Geological and Mining Engineering, Polytechnique Montreal CP Québec Canada
| | - Andrew J Whelton
- Purdue University, Lyles School of Civil Engineering, Division of Environmental and Ecological Engineering West Lafayette IN
| |
Collapse
|
34
|
Julien R, Dreelin E, Whelton AJ, Lee J, Aw TG, Dean K, Mitchell J. Knowledge gaps and risks associated with premise plumbing drinking water quality. ACTA ACUST UNITED AC 2020. [DOI: 10.1002/aws2.1177] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Ryan Julien
- Department of Biosystems and Agricultural EngineeringMichigan State University East Lansing Michigan
| | - Erin Dreelin
- Department of Fisheries and WildlifeMichigan State University East Lansing Michigan
| | - Andrew J. Whelton
- Lyles School of Civil Engineering and Environmental and Ecological EngineeringPurdue University West Lafayette Indiana
| | - Juneseok Lee
- Department of Civil and Environmental EngineeringManhattan College Riverdale New York
| | - Tiong Gim Aw
- Department of Environmental Health Sciences, School of Public Health and Tropical MedicineTulane University New Orleans Louisiana
| | - Kara Dean
- Department of Biosystems and Agricultural EngineeringMichigan State University East Lansing Michigan
| | - Jade Mitchell
- Department of Biosystems and Agricultural EngineeringMichigan State University East Lansing Michigan
| |
Collapse
|
35
|
Paniagua AT, Paranjape K, Hu M, Bédard E, Faucher SP. Impact of temperature on Legionella pneumophila, its protozoan host cells, and the microbial diversity of the biofilm community of a pilot cooling tower. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 712:136131. [PMID: 31931228 DOI: 10.1016/j.scitotenv.2019.136131] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Revised: 12/13/2019] [Accepted: 12/13/2019] [Indexed: 06/10/2023]
Abstract
Legionella pneumophila is a waterborne bacterium known for causing Legionnaires' Disease, a severe pneumonia. Cooling towers are a major source of outbreaks, since they provide ideal conditions for L. pneumophila growth and produce aerosols. In such systems, L. pneumophila typically grow inside protozoan hosts. Several abiotic factors such as water temperature, pipe material and disinfection regime affect the colonization of cooling towers by L. pneumophila. The local physical and biological factors promoting the growth of L. pneumophila in water systems and its spatial distribution are not well understood. Therefore, we built a lab-scale cooling tower to study the dynamics of L. pneumophila colonization in relationship to the resident microbiota and spatial distribution. The pilot was filled with water from an operating cooling tower harboring low levels of L. pneumophila. It was seeded with Vermamoeba vermiformis, a natural host of L. pneumophila, and then inoculated with L. pneumophila. After 92 days of operation, the pilot was disassembled, the water was collected, and biofilm was extracted from the pipes. The microbiome was studied using 16S rRNA and 18S rRNA genes amplicon sequencing. The communities of the water and of the biofilm were highly dissimilar. The relative abundance of Legionella in water samples reached up to 11% whereas abundance in the biofilm was extremely low (≤0.5%). In contrast, the host cells were mainly present in the biofilm. This suggests that L. pneumophila grows in host cells associated with biofilm and is then released back into the water following host cell lysis. In addition, water temperature shaped the bacterial and eukaryotic community of the biofilm, indicating that different parts of the systems may have different effects on Legionella growth.
Collapse
Affiliation(s)
- Adriana Torres Paniagua
- Department of Natural Resource Sciences, McGill University, 21111 Lakeshore Drive, Ste-Anne-de-Bellevue, Quebec, H9X 3V9, Canada
| | - Kiran Paranjape
- Department of Natural Resource Sciences, McGill University, 21111 Lakeshore Drive, Ste-Anne-de-Bellevue, Quebec, H9X 3V9, Canada
| | - Mengqi Hu
- Department of Natural Resource Sciences, McGill University, 21111 Lakeshore Drive, Ste-Anne-de-Bellevue, Quebec, H9X 3V9, Canada
| | - Emilie Bédard
- Department of Natural Resource Sciences, McGill University, 21111 Lakeshore Drive, Ste-Anne-de-Bellevue, Quebec, H9X 3V9, Canada; Department of Civil Engineering, Polytechnique Montreal, P.O. Box 6079, Station Centre-Ville, Montreal, Quebec H3C 3A7, Canada.
| | - Sébastien P Faucher
- Department of Natural Resource Sciences, McGill University, 21111 Lakeshore Drive, Ste-Anne-de-Bellevue, Quebec, H9X 3V9, Canada.
| |
Collapse
|
36
|
Evaluation of Legionella pneumophila Decrease in Hot Water Network of Four Hospital Buildings after Installation of Electron Time Flow Taps. WATER 2020. [DOI: 10.3390/w12010210] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Legionella spp. control is a critical issue in hospital with old water networks. Chemical disinfection methods are applied as a control measure over prolonged time periods, but Legionella may be resistant to chemical agents in pipeworks with low flow and frequent water stagnation. We evaluated Legionella spp. colonization in the hot water network of Italian hospitals after the installation of time flow taps (TFTs). In the period between 2017 and 2019, TFTs were installed in four hospital water networks. They were programmed in order to obtain a hot water flow of 192 L/day from each TFTs. A continuous chlorination system (chlorine dioxide) and a cold water pre-filtration device were applied in all the buildings. Before and after TFT installation, Legionella spp. was investigated at scheduled times. Before TFT installation, Legionella pneumophila was detected in all the hospitals with counts ranging from 2 × 102 to 1.4 × 105 CFU/L. After TFT installation, a loss in Legionella pneumophila culturability was always achieved in the period between 24 h and 15 days. Total chlorine concentration (Cl2) was detected in the range between 0.23 and 0.36 mg/L while temperature values were from 44.8 to 53.2 °C. TFTs together with chemical disinfection represent a method which improve water quality and disinfectant efficacy, reducing Legionella colonization in dead-end sections.
Collapse
|
37
|
Socio-Economic and Environmental Factors Related to Spatial Differences in Human Non-Tuberculous Mycobacterial Diseases in the Czech Republic. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:ijerph16203969. [PMID: 31627484 PMCID: PMC6843547 DOI: 10.3390/ijerph16203969] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Accepted: 10/16/2019] [Indexed: 02/07/2023]
Abstract
Non-tuberculous mycobacteria (NTM) are ubiquitous environmental bacteria that can induce pulmonary and non-pulmonary diseases in susceptible persons. It is reported that the prevalence of NTM diseases is increasing in developed countries, but this differs by regions and countries. NTM species distribution and the rate of diseases caused by NTM vary widely in the historical territories of Moravia and Silesia (Czech Republic). This epidemiologic study of NTM diseases covers the period 2012–2018, reviews isolates obtained from patients with clinical disease and investigates correlations with related socio-economic and environmental factors. Individual NTM patients were included only once during the studied period and results were presented as incidence rate per year. The most frequently isolated NTM meeting the microbiological and clinical criteria in the study were the Mycobacterium avium-intracellulare complex, followed by Mycobacterium kansasii and Mycobacteriumxenopi. A previously described endemic incidence of M.kansasii in the Karviná district and M.xenopi in the Ostrava district was also observed in this study. The incidence of NTM patients in the whole studied territory was 1.10/100,000 inhabitants (1.33/100,000 in men and 0.88/100,000 in women). The annual incidence of lymphadenitis in children (≤5 years of age) was 2.35/100,000 of the population of children during the 7 year period but increased in the year 2018 to 5.95/100,000. The rate of human tuberculosis in the studied area was 1.97/100,000 inhabitants. The incidence of NTM pulmonary diseases correlated with a lower socio-economic status (r = 0.63) and a higher concentration of benzo[a]pyrene pollution in the air (r = 0.64).
Collapse
|
38
|
Bédard E, Paranjape K, Lalancette C, Villion M, Quach C, Laferrière C, Faucher SP, Prévost M. Legionella pneumophila levels and sequence-type distribution in hospital hot water samples from faucets to connecting pipes. WATER RESEARCH 2019; 156:277-286. [PMID: 30925374 DOI: 10.1016/j.watres.2019.03.019] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 03/08/2019] [Accepted: 03/14/2019] [Indexed: 05/07/2023]
Abstract
Recent studies have reported increased levels of Legionella pneumophila (Lp) at points of use compared to levels in primary and secondary components of hot water systems, suggesting possible selection by environmental conditions. In this study, concentrations of Lp in a hospital hot water system were evaluated by profile sampling, collecting successive water samples to determine the prevalence at the faucet (distal) and upstream piping before and after a system intervention to increase temperature. Lp strain diversity was compared between different points of use and different areas of the hot water system (i.e., tap, intermediate piping and main upflow piping). In total, 47 isolates were recovered from 32 positive hot water samples collected from designated taps, showers and recirculation loops; these isolates were subsequently analyzed by sequence-based typing (SBT). Lp levels were comparable between first draw (500 mL) and flushed (2 and 5 min) samples, whereas a decrease was observed in the amount of culturable cells (1 log). Two sequence types (STs) were identified throughout the system. ST378 (sg4/10) was present in 91% of samples, while ST154-like (sg1) was present in 41%; both STs were simultaneously recovered in 34% of samples. Isolated STs displayed comparable tolerance to copper (0.8-5 mg/L) and temperature (55 °C, 1 h) exposure. The ability to replicate within THP1 cells and Acanthamoeba castellanii was similar between the two STs and a comparative environmental outbreak strain. The low Lp diversity and the detection of both Lp sequence types in repeated subsequent samples collected from positive faucets in a hospital wing suggest a minimal impact of the distal conditions on strain selection for the sampled points, as well as a possible adaptation to stressors present in the system, leading to the predominance of a few strains.
Collapse
Affiliation(s)
- Emilie Bédard
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC, Canada; Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, QC, Canada.
| | - Kiran Paranjape
- Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, QC, Canada
| | - Cindy Lalancette
- Laboratoire de santé publique du Québec, Sainte-Anne-de-Bellevue, QC, Canada
| | - Manuela Villion
- Centre d'expertise en analyse environnementale du Québec, Ministère de l'Environnement et de la Lutte contre les changements climatiques, Québec, Canada
| | - Caroline Quach
- Department of Microbiology, Infectiology and Immunology, Université de Montréal, Montréal, QC, Canada
| | - Céline Laferrière
- Department of Microbiology, Infectiology and Immunology, Université de Montréal, Montréal, QC, Canada
| | - Sebastien P Faucher
- Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, QC, Canada
| | - Michèle Prévost
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC, Canada
| |
Collapse
|
39
|
Dowdell K, Haig SJ, Caverly LJ, Shen Y, LiPuma JJ, Raskin L. Nontuberculous mycobacteria in drinking water systems - the challenges of characterization and risk mitigation. Curr Opin Biotechnol 2019; 57:127-136. [PMID: 31003169 DOI: 10.1016/j.copbio.2019.03.010] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2018] [Revised: 03/05/2019] [Accepted: 03/05/2019] [Indexed: 12/18/2022]
Abstract
Nontuberculous mycobacteria (NTM) pulmonary infections are a growing concern worldwide, with a disproportionate incidence in persons with pre-existing health conditions. NTM have frequently been found in municipally-treated drinking water and building plumbing, leading to the hypothesis that an important source of NTM exposure is drinking water. The identification and quantification of NTM in environmental samples are complicated by genetic variability among NTM species, making it challenging to determine if clinically relevant NTM are present. Additionally, their unique cellular features and lifestyles make NTM and their nucleic acids difficult to recover. This review highlights a recent work focused on quantification and characterization of NTM and on understanding the influence of source water, treatment plants, distribution systems, and building plumbing on the abundance of NTM in drinking water.
Collapse
Affiliation(s)
- Katherine Dowdell
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Sarah-Jane Haig
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, MI, USA; Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, PA, USA
| | - Lindsay J Caverly
- Department of Pediatrics, University of Michigan, Ann Arbor, MI, USA
| | - Yun Shen
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, MI, USA
| | - John J LiPuma
- Department of Pediatrics, University of Michigan, Ann Arbor, MI, USA
| | - Lutgarde Raskin
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, MI, USA.
| |
Collapse
|
40
|
Identification of Factors Affecting Bacterial Abundance and Community Structures in a Full-Scale Chlorinated Drinking Water Distribution System. WATER 2019. [DOI: 10.3390/w11030627] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Disentangling factors influencing suspended bacterial community structure across distribution system and building plumbing provides insight into microbial control strategies from source to tap. Water quality parameters (residence time, chlorine, and total cells) and bacterial community structure were investigated across a full-scale chlorinated drinking water distribution system. Sampling was conducted in treated water, in different areas of the distribution system and in hospital building plumbing. Bacterial community was evaluated using 16S rRNA gene sequencing. Bacterial community structure clearly differed between treated, distributed, and premise plumbing water samples. While Proteobacteria (60%), Planctomycetes (20%), and Bacteroidetes (10%) were the most abundant phyla in treated water, Proteobacteria largely dominated distribution system sites (98%) and taps (91%). Distributed and tap water differed in their Proteobacteria profile: Alphaproteobacteria was dominant in distributed water (92% vs. 65% in tap waters), whereas Betaproteobacteria was most abundant in tap water (18% vs. 2% in the distribution system). Finally, clustering of bacterial community profiles was largely explained by differences in chlorine residual concentration, total bacterial count, and water residence time. Residual disinfectant and hydraulic residence time were determinant factors of the community structure in main pipes and building plumbing, rather than treated water bacterial communities.
Collapse
|