1
|
Ferreira CR, Lima Gomes PCFD, Robison KM, Cooper BR, Shannahan JH. Implementation of multiomic mass spectrometry approaches for the evaluation of human health following environmental exposure. Mol Omics 2024; 20:296-321. [PMID: 38623720 PMCID: PMC11163948 DOI: 10.1039/d3mo00214d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Accepted: 03/22/2024] [Indexed: 04/17/2024]
Abstract
Omics analyses collectively refer to the possibility of profiling genetic variants, RNA, epigenetic markers, proteins, lipids, and metabolites. The most common analytical approaches used for detecting molecules present within biofluids related to metabolism are vibrational spectroscopy techniques, represented by infrared, Raman, and nuclear magnetic resonance (NMR) spectroscopies and mass spectrometry (MS). Omics-based assessments utilizing MS are rapidly expanding and being applied to various scientific disciplines and clinical settings. Most of the omics instruments are operated by specialists in dedicated laboratories; however, the development of miniature portable omics has made the technology more available to users for field applications. Variations in molecular information gained from omics approaches are useful for evaluating human health following environmental exposure and the development and progression of numerous diseases. As MS technology develops so do statistical and machine learning methods for the detection of molecular deviations from personalized metabolism, which are correlated to altered health conditions, and they are intended to provide a multi-disciplinary overview for researchers interested in adding multiomic analysis to their current efforts. This includes an introduction to mass spectrometry-based omics technologies, current state-of-the-art capabilities and their respective strengths and limitations for surveying molecular information. Furthermore, we describe how knowledge gained from these assessments can be applied to personalized medicine and diagnostic strategies.
Collapse
Affiliation(s)
- Christina R Ferreira
- Purdue Metabolite Profiling Facility, Purdue University, West Lafayette, IN 47907, USA.
| | | | - Kiley Marie Robison
- School of Health Sciences, College of Health and Human Sciences, Purdue University, West Lafayette, IN 47907, USA
| | - Bruce R Cooper
- Purdue Metabolite Profiling Facility, Purdue University, West Lafayette, IN 47907, USA.
| | - Jonathan H Shannahan
- School of Health Sciences, College of Health and Human Sciences, Purdue University, West Lafayette, IN 47907, USA
| |
Collapse
|
2
|
Tata A, Zacometti C, Massaro A, Bragolusi M, Ceroni S, Falappa S, Prataviera D, Merenda M, Piro R, Catania S. Empowering veterinary clinical diagnosis in industrial poultry production by ambient mass spectrometry and chemiometrics: a new approach for precise poultry farming. Poult Sci 2024; 103:103709. [PMID: 38598914 PMCID: PMC11017065 DOI: 10.1016/j.psj.2024.103709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 03/22/2024] [Accepted: 03/28/2024] [Indexed: 04/12/2024] Open
Abstract
Untargeted metabolomic profiling, by ambient mass spectrometry and chemometric tools, has made a dramatic impact on human disease detection. In a similar vein, this study attempted the translation of this clinical human disease experience to farmed poultry for precise veterinary diagnosis. As a proof of principle, in this diagnostic/prognostic study, direct analysis in real-time high resolution mass spectrometry (DART-HRMS) was used in an untargeted manner to analyze fresh tissues (abdominal fat, leg skin, liver, and leg muscle) of pigmented and non-pigmented broilers to investigate the causes of lack of pigmentation in an industrial poultry farm. Afterwards, statistical analysis was applied to the DART-HRMS data to retrieve the molecular features that codified for 2 broiler groups, that is, properly pigmented and non-pigmented broilers. Higher abundance of oxidized lipids, high abundance of oxidized bile derivatives, and lower levels of tocopherol isomers (Vitamin E) and retinol (Vitamin A) were captured in nonpigmented than in pigmented broilers. In addition, conventional rapid analyses were used: 1) color parameters of the tissues of pigmented and non-pigmented broilers were measured to rationalize the color differences in abdominal fat, leg skin and leg muscle, and 2) macronutrients were determined in broiler leg muscle, to capture a detailed picture of the pathology and exclude other possible causes. In this study, the DART-HRMS system performed well in retrieving valuable chemical information from broilers that explained the differences between the 2 groups of broilers in absorption of xanthophylls and the subsequent lack of proper broiler pigmentation in affected broilers. The results suggest this technology could be useful in providing near real-time feedback to aid in veterinary decision-making in poultry farming.
Collapse
Affiliation(s)
- Alessandra Tata
- Istituto Zooprofilattico Sperimentale delle Venezie, Laboratorio di Chimica Sperimentale, Vicenza, Italy.
| | - Carmela Zacometti
- Istituto Zooprofilattico Sperimentale delle Venezie, Laboratorio di Chimica Sperimentale, Vicenza, Italy
| | - Andrea Massaro
- Istituto Zooprofilattico Sperimentale delle Venezie, Laboratorio di Chimica Sperimentale, Vicenza, Italy
| | - Marco Bragolusi
- Istituto Zooprofilattico Sperimentale delle Venezie, Laboratorio di Chimica Sperimentale, Vicenza, Italy
| | - Simona Ceroni
- Fileni Alimentare SPA, Località Cerrete Collicelli N° 8, Cingoli, Macerata 62011, Italy
| | - Sonia Falappa
- Fileni Alimentare SPA, Località Cerrete Collicelli N° 8, Cingoli, Macerata 62011, Italy
| | - Davide Prataviera
- Avian Medicine Laboratory, Istituto Zooprofilattico Sperimentale delle Venezie, Buttapietra, Verona 37060, Italy
| | - Marianna Merenda
- Avian Medicine Laboratory, Istituto Zooprofilattico Sperimentale delle Venezie, Buttapietra, Verona 37060, Italy
| | - Roberto Piro
- Istituto Zooprofilattico Sperimentale delle Venezie, Laboratorio di Chimica Sperimentale, Vicenza, Italy
| | - Salvatore Catania
- Avian Medicine Laboratory, Istituto Zooprofilattico Sperimentale delle Venezie, Buttapietra, Verona 37060, Italy
| |
Collapse
|
3
|
Sorokin AA, Pekov SI, Zavorotnyuk DS, Shamraeva MM, Bormotov DS, Popov IA. Modern machine-learning applications in ambient ionization mass spectrometry. MASS SPECTROMETRY REVIEWS 2024. [PMID: 38671553 DOI: 10.1002/mas.21886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 03/29/2024] [Accepted: 04/05/2024] [Indexed: 04/28/2024]
Abstract
This article provides a comprehensive overview of the applications of methods of machine learning (ML) and artificial intelligence (AI) in ambient ionization mass spectrometry (AIMS). AIMS has emerged as a powerful analytical tool in recent years, allowing for rapid and sensitive analysis of various samples without the need for extensive sample preparation. The integration of ML/AI algorithms with AIMS has further expanded its capabilities, enabling enhanced data analysis. This review discusses ML/AI algorithms applicable to the AIMS data and highlights the key advancements and potential benefits of utilizing ML/AI in the field of mass spectrometry, with a focus on the AIMS community.
Collapse
Affiliation(s)
- Anatoly A Sorokin
- Laboratory of Molecular Medical Diagnostics, Moscow Institute of Physics and Technology, Dolgoprudny, Russia
| | - Stanislav I Pekov
- Mass Spectrometry Laboratory, Skolkovo Institute of Science and Technology, Moscow, Russia
- Translational Medicine Laboratory, Siberian State Medical University, Tomsk, Russia
- Department for Molecular and Biological Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Russia
| | - Denis S Zavorotnyuk
- Laboratory of Molecular Medical Diagnostics, Moscow Institute of Physics and Technology, Dolgoprudny, Russia
| | - Mariya M Shamraeva
- Laboratory of Molecular Medical Diagnostics, Moscow Institute of Physics and Technology, Dolgoprudny, Russia
| | - Denis S Bormotov
- Laboratory of Molecular Medical Diagnostics, Moscow Institute of Physics and Technology, Dolgoprudny, Russia
| | - Igor A Popov
- Laboratory of Molecular Medical Diagnostics, Moscow Institute of Physics and Technology, Dolgoprudny, Russia
- Translational Medicine Laboratory, Siberian State Medical University, Tomsk, Russia
| |
Collapse
|
4
|
Zimmerman-Federle H, Ren G, Dowling S, Warren C, Rusyniak D, Avera R, Manicke NE. Plasma drug screening using paper spray mass spectrometry with integrated solid phase extraction. Drug Test Anal 2024. [PMID: 38584344 DOI: 10.1002/dta.3687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 03/04/2024] [Accepted: 03/14/2024] [Indexed: 04/09/2024]
Abstract
Drug overdoses have risen dramatically in recent years. We developed a simple nontargeted method using a disposable paper spray cartridge with an integrated solid phase extraction column. This method was used to screen for ~160 fentanyl analogs, synthetic cannabinoids, other synthetic drugs, and traditional drugs of abuse in over 300 authentic overdose samples collected at emergency departments in Indianapolis. A solid phase extraction step was implemented on the paper spray cartridge to enable subnanograms per milliliter synthetic drugs screening in plasma. Analysis was performed on a quadrupole orbitrap mass spectrometer using the sequential window acquisition of all theoretical fragment ion spectra approach in which tandem mass spectrometry was performed using 7 m/z isolation windows in the quadrupole. Calibration curves with isotopically labeled internal standards were constructed for 35 of the most frequently encountered synthetic and traditional illicit drugs by US toxicology labs. Additional qualitative-only drugs in a suspect screening list were also included. Limits of detection in plasma for synthetic cannabinoids ranged from 0.1 to 0.5 and 0.1 to 0.3 ng/mL for fentanyl and its analogs and between 1 and 5 ng/mL for most other drugs. Relative matrix effects were evaluated by determining the variation of the calibration slope in 10 different lots of biofluid and found to be between 3% and 20%. The method was validated on authentic overdose samples collected from two emergency departments in Indianapolis, Indiana, from suspected or known overdoses. Commonly detected synthetic drugs included fentanyl related substances, designer benzodiazepines such as flubromazolam, and the synthetic cannabinoid 5F-PB-22.
Collapse
Affiliation(s)
- Hannah Zimmerman-Federle
- Department of Chemistry and Chemical Biology, Indiana University-Purdue University Indianapolis, Indianapolis, Indiana, USA
| | - Greta Ren
- Department of Chemistry and Chemical Biology, Indiana University-Purdue University Indianapolis, Indianapolis, Indiana, USA
| | - Sarah Dowling
- Department of Chemistry and Chemical Biology, Indiana University-Purdue University Indianapolis, Indianapolis, Indiana, USA
| | - Cassandra Warren
- Department of Chemistry and Chemical Biology, Indiana University-Purdue University Indianapolis, Indianapolis, Indiana, USA
| | - Daniel Rusyniak
- School of Medicine, Indiana University, Indianapolis, Indiana, USA
| | - Robert Avera
- School of Medicine, Indiana University, Indianapolis, Indiana, USA
| | - Nicholas E Manicke
- Department of Chemistry and Chemical Biology, Indiana University-Purdue University Indianapolis, Indianapolis, Indiana, USA
| |
Collapse
|
5
|
Henderson A, Heaney LM, Rankin-Turner S. Ambient ionisation mass spectrometry for drug and toxin analysis: A review of the recent literature. Drug Test Anal 2024. [PMID: 38326879 DOI: 10.1002/dta.3644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 11/17/2023] [Accepted: 12/28/2023] [Indexed: 02/09/2024]
Abstract
Ambient ionisation mass spectrometry (AIMS) is a form of mass spectrometry whereby analyte ionisation occurs outside of a vacuum source under ambient conditions. This enables the direct analysis of samples in their native state, with little or no sample preparation and without chromatographic separation. The removal of these steps facilitates a much faster analytical process, enabling the direct analysis of samples within minutes if not seconds. Consequently, AIMS has gained rapid popularity across a diverse range of applications, in particular the analysis of drugs and toxins. Numerous fields rely upon mass spectrometry for the detection and identification of drugs, including clinical diagnostics, forensic chemistry, and food safety. However, all of these fields are hindered by the time-consuming and laboratory-confined nature of traditional techniques. As such, the potential for AIMS to resolve these challenges has resulted in a growing interest in ambient ionisation for drug and toxin analysis. Since the early 2000s, forensic science, diagnostic testing, anti-doping, pharmaceuticals, environmental analysis and food safety have all seen a marked increase in AIMS applications, foreshadowing a new future for drug testing. In this review, some of the most promising AIMS techniques for drug analysis will be discussed, alongside different applications of AIMS published over a 5-year period, to provide a summary of the recent research activity for ambient ionisation for drug and toxin analysis.
Collapse
Affiliation(s)
- Alisha Henderson
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Liam M Heaney
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Stephanie Rankin-Turner
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, Maryland, USA
| |
Collapse
|
6
|
Mathias S, Amerio-Cox M, Jackson T, Douce D, Sage A, Luke P, Sleeman R, Crean C, Sears P. Selectivity of Explosives Analysis with Ambient Ionization Single Quadrupole Mass Spectrometry: Implications for Trace Detection. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:50-61. [PMID: 38086767 PMCID: PMC10767746 DOI: 10.1021/jasms.3c00305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 11/03/2023] [Accepted: 11/27/2023] [Indexed: 01/04/2024]
Abstract
Ambient ionization (AI) is a rapidly growing field in mass spectrometry (MS). It allows for the direct analysis of samples without any sample preparation, making it a promising technique for the detection of explosives. Previous studies have shown that AI can be used to detect a variety of explosives, but the exact gas-phase reactions that occur during ionization are not fully understood. This is further complicated by differences in mass spectrometers and individual experimental set ups between researchers. This study investigated the gas-phase ion reactions of five different explosives using a variety of AI techniques coupled to a Waters QDa mass spectrometer to identify selective ions for explosive detection and identification based on the applied ambient ionization technique. The results showed that the choice of the ion source can have a significant impact on the number of ions observed. This can affect the sensitivity and selectivity of the data produced. The findings of this study provide new insights into the gas-phase ion reactions of explosives and could lead to the development of more sensitive and selective AI-based methods for their detection.
Collapse
Affiliation(s)
- Simone Mathias
- School
of Chemistry and Chemical Engineering, University
of Surrey, Guildford GU2 7XH, U.K.
| | - Marius Amerio-Cox
- School
of Chemistry and Chemical Engineering, University
of Surrey, Guildford GU2 7XH, U.K.
| | - Toni Jackson
- School
of Chemistry and Chemical Engineering, University
of Surrey, Guildford GU2 7XH, U.K.
| | - David Douce
- Waters
Corporation, Stamford
Avenue, Wilmslow SK9 4AX, U.K.
| | - Ashley Sage
- Waters
Corporation, Stamford
Avenue, Wilmslow SK9 4AX, U.K.
| | - Peter Luke
- Mass
Spec Analytical, Future Space UWE North Gate, Bristol BS34 8RB, U.K.
| | - Richard Sleeman
- Mass
Spec Analytical, Future Space UWE North Gate, Bristol BS34 8RB, U.K.
| | - Carol Crean
- School
of Chemistry and Chemical Engineering, University
of Surrey, Guildford GU2 7XH, U.K.
| | - Patrick Sears
- School
of Chemistry and Chemical Engineering, University
of Surrey, Guildford GU2 7XH, U.K.
| |
Collapse
|
7
|
Miskulin A, Wallace B, Gill C, Hore D. A strategy for the detection of benzodiazepine drugs using low-resolution paper-spray mass spectrometry for harm reduction drug checking. Drug Test Anal 2023. [PMID: 38145889 DOI: 10.1002/dta.3630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 11/02/2023] [Accepted: 12/07/2023] [Indexed: 12/27/2023]
Abstract
The ability to detect newly emerging substances is of great importance in reducing harms for people who use drugs. New psychoactive substances including novel benzodiazepines in the illicit drug supply have been linked to high rates of overdose deaths while complicating drug checking as an overdose prevention strategy. Paper-spray mass spectrometry (PS-MS) has emerged as a novel strategy to rapidly detect trace components in street drug samples. While targeted, low-resolution PS-MS methods have proven effective, newly emerging substances are often missed. To address this, a method was applied to low-resolution full-scan PS-MS data to aid in the early detection and identification of novel benzodiazepines in the unregulated drug supply. Using the developed method, true positives rates of 0.89 and 0.75 were achieved for bromazolam and etizolam in street samples obtained in a community drug checking service. The applicability of the method was further demonstrated for a novel benzodiazepine, desalkylgidazepam, that has recently emerged in the illicit drug supply.
Collapse
Affiliation(s)
- Allie Miskulin
- Department of Chemistry, University of Victoria, Victoria, British Columbia, Canada
| | - Bruce Wallace
- School of Social Work, University of Victoria, Victoria, British Columbia, Canada
- Canadian Institute for Substance Use Research, University of Victoria, Victoria, British Columbia, Canada
| | - Chris Gill
- Department of Chemistry, University of Victoria, Victoria, British Columbia, Canada
- Canadian Institute for Substance Use Research, University of Victoria, Victoria, British Columbia, Canada
- Department of Chemistry, Applied Environmental Research Laboratories (AERL), Vancouver Island University, Nanaimo, British Columbia, Canada
- Department of Chemistry, Simon Fraser University, Burnaby, British Columbia, Canada
- Department of Environmental and Occupational Health Sciences, University of Washington, Seattle, Washington, USA
| | - Dennis Hore
- Department of Chemistry, University of Victoria, Victoria, British Columbia, Canada
- Canadian Institute for Substance Use Research, University of Victoria, Victoria, British Columbia, Canada
- Department of Computer Science, University of Victoria, Victoria, British Columbia, Canada
| |
Collapse
|
8
|
Liu S, Xu W, Zhai Y. Swab-in-Capillary Electrospray Ionization and a Miniature Mass Spectrometer for In Situ Drug Analysis. Anal Chem 2023; 95:16987-16995. [PMID: 37948617 DOI: 10.1021/acs.analchem.3c03279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2023]
Abstract
In situ analysis of drugs has been in increasing demand in many fields. As an updated version of capillary-in-capillary electrospray ionization (CC-ESI) developed previously, a disposable swab-in-capillary electrospray ionization (SC-ESI) source was designed in this study. With a micro medical swab for sampling and an integrated filter membrane for online filtration, SC-ESI was able to directly sample and MS analyze complex samples without the need for pretreatment. Coupled with a miniature mass spectrometer, SC-ESI was applied for direct analysis of effective ingredients in therapeutic drugs (in tablet, capsule, and liquid droplet) and drugs in saliva and quantitation of therapeutic drugs in blood. The limits of detection in absolute amounts were obtained as 1 ng for fentanyl and 0.5 ng for cocaine in saliva. Combining with an internal standard method, SC-ESI acquired linear quantitation ranges of 100-5000 ng/mL for imatinib in whole blood and 100-2000 ng/mL for clozapine in serum with high accuracies and precisions. The entire analysis process, from sampling to data acquisition, can be completed in less than 2 min. As demonstrated as a cheap, portable, and sampling-effective ionization source, SC-ESI has shown great potential for in situ drug analysis, especially in border drug screening and clinical therapeutic drug monitoring.
Collapse
Affiliation(s)
- Siyu Liu
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Wei Xu
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Yanbing Zhai
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China
| |
Collapse
|
9
|
Kumar BS. Recent Advances and Applications of Ambient Mass Spectrometry Imaging in Cancer Research: An Overview. Mass Spectrom (Tokyo) 2023; 12:A0129. [PMID: 37789912 PMCID: PMC10542858 DOI: 10.5702/massspectrometry.a0129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 08/25/2023] [Indexed: 10/05/2023] Open
Abstract
Cancer metabolic variability has a significant impact on both diagnosis and treatment outcomes. The discovery of novel biological indicators and metabolic dysregulation, can significantly rely on comprehension of the modified metabolism in cancer, is a research focus. Tissue histology is a critical feature in the diagnostic testing of many ailments, such as cancer. To assess the surgical margin of the tumour on patients, frozen section histology is a tedious, laborious, and typically arbitrary method. Concurrent monitoring of ion images in tissues facilitated by the latest advancements in mass spectrometry imaging (MSI) is far more efficient than optical tissue image analysis utilized in conventional histopathology examination. This article focuses on the "desorption electrospray ionization (DESI)-MSI" technique's most recent advancements and uses in cancer research. DESI-MSI can provide wealthy information based on the variances in metabolites and lipids in normal and cancerous tissues by acquiring ion images of the lipid and metabolite variances on biopsy samples. As opposed to a systematic review, this article offers a synopsis of the most widely employed cutting-edge DESI-MSI techniques in cancer research.
Collapse
Affiliation(s)
- Bharath S. Kumar
- Correspondence to: Bharath S. Kumar, 21, B2, 27th Street, Nanganallur, Chennai, India, e-mail:
| |
Collapse
|
10
|
Nazim T, Lusina A, Cegłowski M. Recent Developments in the Detection of Organic Contaminants Using Molecularly Imprinted Polymers Combined with Various Analytical Techniques. Polymers (Basel) 2023; 15:3868. [PMID: 37835917 PMCID: PMC10574876 DOI: 10.3390/polym15193868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 09/13/2023] [Accepted: 09/21/2023] [Indexed: 10/15/2023] Open
Abstract
Molecularly imprinted polymers (MIPs) encompass a diverse array of polymeric matrices that exhibit the unique capacity to selectively identify a designated template molecule through specific chemical moieties. Thanks to their pivotal attributes, including exceptional selectivity, extended shelf stability, and other distinct characteristics, this class of compounds has garnered interest in the development of highly responsive sensor systems. As a result, the incorporation of MIPs in crafting distinctive sensors and analytical procedures tailored for specific analytes across various domains has increasingly become a common practice within contemporary analytical chemistry. Furthermore, the range of polymers amenable to MIP formulation significantly influences the potential utilization of both conventional and innovative analytical methodologies. This versatility expands the array of possibilities in which MIP-based sensing can be employed in recognition systems. The following review summarizes the notable progress achieved within the preceding seven-year period in employing MIP-based sensing techniques for analyte determination.
Collapse
Affiliation(s)
| | | | - Michał Cegłowski
- Faculty of Chemistry, Adam Mickiewicz University in Poznań, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland; (T.N.); (A.L.)
| |
Collapse
|
11
|
Muggli TM, Schürch S. Analysis of Pesticide Residues on Fruit Using Swab Spray Ionization Mass Spectrometry. Molecules 2023; 28:6611. [PMID: 37764387 PMCID: PMC10537605 DOI: 10.3390/molecules28186611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 09/06/2023] [Accepted: 09/13/2023] [Indexed: 09/29/2023] Open
Abstract
The vast quantity and high variety of pesticides globally used in agriculture entails considerable risks for the environment and requires ensuring the safety of food products. Therefore, powerful analytical tools are needed to acquire qualitative and quantitative data for monitoring pesticide residues. The development of ambient ionization mass spectrometry methods in the past two decades has demonstrated numerous ways to generate ions under atmospheric conditions and simultaneously to reduce the need for extended sample preparation and circumvent chromatographic separation prior to mass analysis. Swab spray ionization enables the generation of ions directly from swabs via the application of high voltage and solvent flow. In this study, swab sampling of fruit surfaces and subsequent ionization directly from the swab in a modified electrospray ion source was employed for the screening and quantitation of pesticide residues. Aspects regarding sample collection, sampling efficacy on different surfaces, and swab background are discussed. The effect of solvent composition on pesticide-sodium adduct formation and the suppression of ionization by the background matrix have been investigated. Furthermore, a novel approach for the quantitation of pesticide residues based on depletion curve areas is presented. It is demonstrated that swab spray ionization is an effective and quick method for spectral library-based identification and the quantitative analysis of polar contact pesticide residues on food.
Collapse
Affiliation(s)
| | - Stefan Schürch
- Department of Chemistry, Biochemistry and Pharmaceutical Sciences, University of Bern, 3012 Bern, Switzerland;
| |
Collapse
|
12
|
Shen X, Xu Y, Huang J, Wu P, Zhou W, Chen Y. A comparative study on two methods of ocular surface microbial sampling. BMC Ophthalmol 2023; 23:228. [PMID: 37217905 DOI: 10.1186/s12886-023-02979-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Accepted: 05/17/2023] [Indexed: 05/24/2023] Open
Abstract
PURPOSE To compare the effect of traditional conjunctival sac swab sampling (A) with aerosolization ocular surface microorganism sampling (B),a novel microbial sampling method, in detecting ocular microbial infection. METHODS The study included 61 participants (122 eyes) enrolled at the Eye Hospital, Wenzhou Medical University from December, 2021 to March, 2023. Each eye of the participants underwent sampling first with method A then B.Before aerosolization sampling, the air environment was disinfected and sampled as blank air control sample. Subsequently, the air pulses impinging the ocular surface causes dehiscence of the tear film covering the ocular surface and aerosols are formed.The microorganisms from the ocular surface attach to the aerosols generated as aerosolization ocular surface microorganism and be sampled as subject sample by bio-aerosol sampler.The samples were collected and incubated at 25℃ for 3-5 days and 37℃ for 24-48 h.The colonies were counted and identified by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. RESULTS The accuracy in Group B was higher than that in Group A (45.8% vs. 38.3%, P = 0.289). There was a slight level of agreement between the results from both the sampling methods (k = 0.031, P = 0.730). The sensitivity in Group B was higher than that in Group A (57.1% vs. 35.7%, P = 0.453). The specificity results in Group B was higher than that in Group A (44.3% vs. 38.7%, P = 0.480). There were 12 and 37 types of microbes detected in Groups A and B, respectively. CONCLUSIONS Compared with traditional swab sampling, the novel aerosolization sampling method shows higher accuracy and more comprehensive detection of microbes; however, it cannot completely replace swab sampling. The novel method can be a novel conducive strategy and supplement swab sampling to auxiliary diagnose ocular surface infection.
Collapse
Affiliation(s)
- Xinyi Shen
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
| | - Yi Xu
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
| | - Jinzhi Huang
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
| | - Peiyu Wu
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
| | - Weihe Zhou
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
| | - Yanyan Chen
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
| |
Collapse
|
13
|
Dvorak J, Novakova J, Kraftova L, Studentova V, Matejovic M, Radej J, Karvunidis T, Horak J, Kralovcova M, Hrabak J, Kalaninova Z, Volny M, Novak P, Pompach P. The rapid detection of procalcitonin in septic serum using immunoaffinity MALDI chips. Clin Proteomics 2023; 20:20. [PMID: 37170190 PMCID: PMC10176672 DOI: 10.1186/s12014-023-09410-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Accepted: 04/27/2023] [Indexed: 05/13/2023] Open
Abstract
BACKGROUND Sepsis is a common worldwide health condition with high mortality. It is caused by a dysregulated immune response to the pathogen. Severe infections resulting in sepsis can be also determined by monitoring several bloodstream biomarkers, one of them being pro-hormone procalcitonin (PCT). PCT concentration in the bloodstream correlates well with sepsis and in severe cases increases up to a thousand times from the healthy physiological values in a short time. In this study, we developed a rapid technique for PCT detection by MALDI-TOF mass spectrometry, that uses in-situ enrichment directly on the specialized immuno MALDI chips that are utilized as MALDI plates. The method's ability to detect PCT was confirmed by comparing the results with LC-MS bottom-up workflow. The new method detects intact PCT by its m/z and uncovers its alternations in septic serum. METHODS The MALDI chips used for the detection of PCT were prepared by ambient ion soft landing of anti-PCT antibody on an ITO glass slide. The chips were used for the development of the rapid MALDI-TOF MS method. A parallel method based on affinity enrichment on magnetic beads followed by LC-MS/MS data-dependent peptide microsequencing was used to prove PCT presence in the sample. All samples were also tested by ELISA to determine PCT concentration prior to analyzing them by mass spectrometry methods. RESULTS The MALDI chip method was optimized using recombinant PCT spiked into the human serum. The PCT detection limit was 10 ng/mL. The optimized method was used to analyze 13 sera from patients suffering sepsis. The PCT results were confirmed by LC-MS/MS. The measurement of the intact PCT by the MALDI chip method revealed that sera of patients with severe sepsis have other forms of PCT present, which show post-processing of the primary sequence by cleavage of PCT, resulting in the formation of N and C termini fragments. CONCLUSIONS Procalcitonin from human serum was successfully enriched and detected using immunoaffinity MALDI chips. The intact PCT was characterized in 13 septic patients. The method is more specific compared to non-MS-based immunoaffinity techniques and allows observation of different variants of PCT in septic patients.
Collapse
Affiliation(s)
- Josef Dvorak
- Department of Biochemistry, Faculty of Science, Charles University, Prague, Czech Republic
- Institute of Microbiology, The Czech Academy of Science, Prague, Czech Republic
| | - Jana Novakova
- Institute of Microbiology, The Czech Academy of Science, Prague, Czech Republic
| | - Lucie Kraftova
- Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic
| | - Vendula Studentova
- Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic
| | - Martin Matejovic
- Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic
- Department of Internal Medicine, Faculty of Medicine in Pilsen, Pilsen University Hospital, Charles University, Pilsen, Czech Republic
| | - Jaroslav Radej
- Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic
- Department of Internal Medicine, Faculty of Medicine in Pilsen, Pilsen University Hospital, Charles University, Pilsen, Czech Republic
| | - Thomas Karvunidis
- Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic
- Department of Internal Medicine, Faculty of Medicine in Pilsen, Pilsen University Hospital, Charles University, Pilsen, Czech Republic
| | - Jan Horak
- Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic
- Department of Internal Medicine, Faculty of Medicine in Pilsen, Pilsen University Hospital, Charles University, Pilsen, Czech Republic
| | - Marcela Kralovcova
- Department of Internal Medicine, Faculty of Medicine in Pilsen, Pilsen University Hospital, Charles University, Pilsen, Czech Republic
| | - Jaroslav Hrabak
- Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic
| | - Zuzana Kalaninova
- Department of Biochemistry, Faculty of Science, Charles University, Prague, Czech Republic
- Institute of Microbiology, The Czech Academy of Science, Prague, Czech Republic
| | - Michael Volny
- Institute of Microbiology, The Czech Academy of Science, Prague, Czech Republic
| | - Petr Novak
- Department of Biochemistry, Faculty of Science, Charles University, Prague, Czech Republic
- Institute of Microbiology, The Czech Academy of Science, Prague, Czech Republic
| | - Petr Pompach
- Department of Biochemistry, Faculty of Science, Charles University, Prague, Czech Republic.
- Institute of Microbiology, The Czech Academy of Science, Prague, Czech Republic.
- Institute of Biotechnology, The Czech Academy of Science, Prague, Czech Republic.
| |
Collapse
|
14
|
Zhou W, Nazdrajić E, Pawliszyn J. High-Throughput and Rapid Screening of Drugs of Abuse in Saliva by Multi-Segment Injection Using Solid-Phase Microextraction-Automated Microfluidic Open Interface-Mass Spectrometry. Anal Chem 2023; 95:6367-6373. [PMID: 37021600 PMCID: PMC10848236 DOI: 10.1021/acs.analchem.2c05782] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/07/2023]
Abstract
There is great demand for analytical methods capable of providing high-throughput and rapid screening, especially for anti-doping and clinical point-of-care applications. In this work, automated microfluidic open interface-mass spectrometry (MOI-MS) was used for coupling with high-throughput, automated solid-phase microextraction (SPME) to achieve this objective. The design of the MOI-MS interface provides a continuous and stable electrospray fluid flow to the MS without introducing any bubble, a feature that we exploit to introduce the concept of multi-segment injection for the determination of multiple samples in a single MS run. By eliminating the need to start a new MS run between sample assays, the developed approach provides significantly simplified protocols controlled by programmed software and increased reproducibility. Furthermore, the biocompatible SPME device, which utilizes coating consisting of hydrophilic-lipophilic balanced particles embedded in a polyacrylonitrile (PAN) binder, can be directly used for biological sample analysis, as the PAN acts as both a binder and a matrix-compatible barrier, thus enabling the enrichment of small molecules while eliminating interferences associated with the presence of interfering macromolecules. The above design was employed to develop a fast, quantitative method capable of analyzing drugs of abuse in saliva samples in as little as 75 s per sample. The findings indicate that the developed method provides good analytical performance, with limits of detection ranging between 0.05 and 5 ng/mL for analysis of 16 drugs of abuse, good calibration linear correlation coefficients (R2 ≥ 0.9957), accuracy between 81 and 120%, and excellent precision (RSD% < 13%). Finally, a proof-of-concept experiment was performed to demonstrate the method's suitability for real-time analysis in anti-doping applications.
Collapse
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Emir Nazdrajić
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
15
|
Li Y, Jia K, Pan Y, Han J, Chen J, Wang Y, Ma X, Chen H, Wang S, Xie D, Xiong C, Nie Z. Pocket-Size Wireless Nanoelectrospray Ionization Mass Spectrometry for Metabolic Analysis of Salty Biofluids and Single Cells. Anal Chem 2023; 95:4612-4618. [PMID: 36862115 DOI: 10.1021/acs.analchem.2c04268] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/03/2023]
Abstract
Analysis of volume-limited biological samples such as single cells and biofluids not only benefits clinical purposes but also promotes fundamental research in life sciences. Detection of these samples, however, imposes strict requirements on measurement performance because of the minimal volume and concentrated salts of the samples. Herein, we developed a self-cleaning nanoelectrospray ionization device powered by a pocket-size "MasSpec Pointer" (MSP-nanoESI) for metabolic analysis of salty biological samples with limited volume. The self-cleaning effect induced by Maxwell-Wagner electric stress helps with keeping the borosilicate glass capillary tip free from clogging and thus increasing salt tolerance. This device possesses a high sample economy (about 0.1 μL per test) due to its pulsed high voltage supply, sampling method (dipping the nanoESI tip into analyte solution), and contact-free electrospray ionization (ESI) (the electrode does not touch the analyte solution during ESI). High repeatable results could be acquired by the device with a relative standard deviation (RSD) of 1.02% for voltage output and 12.94% for MS signals of caffeine standard. Single MCF-7 cells were metabolically analyzed directly from phosphate buffered saline, and two types of untreated cerebrospinal fluid from hydrocephalus patients were distinguished with 84% accuracy. MSP-nanoESI gets rid of the bulky apparatus and could be held in hand or put into one's pocket for transportation, and it could operate for more than 4 h without recharge. We believe this device will boost scientific research and clinical usage of volume-limited biological samples with high-concentration salts in a low-cost, convenient, and rapid manner.
Collapse
Affiliation(s)
- Yuze Li
- State Key Laboratory of High-efficiency Utilization of Coal and Green Chemical Engineering, College of Chemistry and Chemical Engineering, Ningxia University, Yinchuan 750021, China.,Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Ke Jia
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yixin Pan
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jing Han
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Junyu Chen
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yiran Wang
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xiaobing Ma
- Aerospace Information Research Institute, Chinese Academy of Sciences Beijing 100094, China
| | - Hongwei Chen
- Department of Neurosurgery for Cerebrospinal Fluid Diseases, Aviation General Hospital, Beijing 100012, China
| | - Shengjie Wang
- Department of Neurosurgery for Cerebrospinal Fluid Diseases, Aviation General Hospital, Beijing 100012, China
| | - Dongcheng Xie
- Department of Neurosurgery for Cerebrospinal Fluid Diseases, Aviation General Hospital, Beijing 100012, China
| | - Caiqiao Xiong
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Zongxiu Nie
- State Key Laboratory of High-efficiency Utilization of Coal and Green Chemical Engineering, College of Chemistry and Chemical Engineering, Ningxia University, Yinchuan 750021, China.,Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
16
|
Pandey S, Hu Y, Anderson PL, Kiser JJ, Cooks RG. Miniature mass spectrometer-based point-of-care assay for measuring phosphatidylethanol in blood. Analyst 2023; 148:1430-1436. [PMID: 36892479 PMCID: PMC10061498 DOI: 10.1039/d3an00098b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2023]
Abstract
We demonstrate proof-of-concept for point-of-care assessment of long-term alcohol consumption by measuring phosphatidylethanol in blood/dried blood spots with nano-electrospray ionization and MS/MS using a miniature mass spectrometer. 'Abstinence', 'moderate', and 'chronic' consumption could be distinguished rapidly for both sample types, and quantitative performance was obtained with blood (LoQ-100 ng mL-1).
Collapse
Affiliation(s)
- Sangeeta Pandey
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA.
| | - Yanyang Hu
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA.
| | - Peter L Anderson
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, Aurora, CO 80045, USA.
| | - Jennifer J Kiser
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, Aurora, CO 80045, USA.
| | - R Graham Cooks
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA.
| |
Collapse
|
17
|
Kim A, Kelly PF, Turner MA, Reynolds JC. Development of a rapid, in-situ analysis method using sheath-flow probe electrospray ionisation-mass spectrometry for the direct identification of cocaine metabolites in dried blood spots. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2023; 37:e9422. [PMID: 36278930 PMCID: PMC9788050 DOI: 10.1002/rcm.9422] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 10/12/2022] [Accepted: 10/18/2022] [Indexed: 06/16/2023]
Abstract
RATIONALE Small amounts of biofluid samples are frequently found at crime scenes; however, existing gold standard methods such as LC-MS frequently require destructive extraction of the sample before a time-consuming analysis which puts strain on forensic analysis providers and can preclude further sample analysis. This study presents the application of sheath-flow probe electrospray ionization-mass spectrometry (sfPESI-MS) to the direct analysis of drug metabolites in dried blood spots (DBS) as a high throughput, minimally destructive alternative. METHODS A rapid direct analysis method using a sfPESI ionisation source coupled to an Orbitrap Exactive mass spectrometer was applied to detect cocaine metabolites (benzoylecgonine, BZE, cocaethylene, CE, and ecgonine methyl ester, EME) from DBS. An optimisation study exploring the use of different chemical modifiers (formic acid and sodium acetate) in the sfPESI probe extraction solvent was conducted to enhance the sensitivity and reproducibility of the sfPESI-MS method. RESULTS Optimisation of the extraction solvent significantly enhanced the sensitivity and reproducibility of the sfPESI-MS method. A quantitative response over a five-point calibration range 0.5 to 10 μg/ml was obtained for BZE (R2 = 0.9979) and CE (R2 = 0.9948). Limits of detection (LOD) of 1.31, 0.29 and 0.15 μg/ml were achieved for EME, BZE and CE, respectively, from 48 h aged DBSs with % RSD (relative standard deviation) across the calibration range ranging between 19%-28% for [BZE + H]+ , 13%-21% for [CE + H]+ and 12%-29% for [EME + H]+ . CONCLUSIONS A rapid (< 20 s) quantitative method for the direct analysis of cocaine metabolites from DBS which requires no prior sample preparation was developed. Although the LOD achieved for BZE (LOD: 0.29 μg/ml) was above the UK threshold limit of exposure for drug driving (0.05 μg/ml), the method may be suitable for use in identifying overdose in forensic analysis.
Collapse
Affiliation(s)
- Ayoung Kim
- Centre for Analytical Science, Department of ChemistryLoughborough UniversityUK
| | - Paul F. Kelly
- Centre for Analytical Science, Department of ChemistryLoughborough UniversityUK
| | - Matthew A. Turner
- Centre for Analytical Science, Department of ChemistryLoughborough UniversityUK
| | - James C. Reynolds
- Centre for Analytical Science, Department of ChemistryLoughborough UniversityUK
| |
Collapse
|
18
|
Wang X, Yang M, Xiao H, Liu D, Pan L, Zhang L, Yang Y, Lu Q, Liu Y, Yang X, Yang B. Determination of nicotine in newborn meconium by high-Resolution ambient mass spectrometry using wooden-Tip spray. Front Chem 2023; 11:1122137. [PMID: 36742034 PMCID: PMC9892440 DOI: 10.3389/fchem.2023.1122137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Accepted: 01/10/2023] [Indexed: 01/20/2023] Open
Abstract
Prenatal exposure to nicotine that are mainly produced from tobacco smoke has been reported to affect infants. Therefore, nicotine exposure is one of important health concerns for newborn screening. Detecting nicotine and its metabolites such as cotinine in meconium were widely used to evaluate the tobacco exposure of pregnancy. In this study, disposable wooden tips were applied for touch sampling of meconium from newborn infants, and then were directly mounted on mass spectrometer (MS) to perform rapid screening of nicotine and cotinine. Choice of extraction/spray solvents was optimized. The limits of detection, reproducibility, linear response for direct analysis of meconium were also investigated. It is found the limits of detection (S/N = 3) to be as low as 0.36 ng/mg and 1.18 ng/mg for nicotine and cotinine, respectively, while the limits of quantitation (S/N = 10) to be 1.19 ng/mg and 3.94 ng/mg for nicotine and cotinine, respectively. The relative standard deviations (RSD) were found to be at 8.4%-19.8% (n = 6) for nicotine and cotinine, a good linear range from 5-500 ng/mL (R 2 > 0.99). These analytical performances are well-accepted levels for ambient mass spectrometer analysis. In this study, evaluation of nicotine and cotinine in 22 puerpera volunteers were conducted by the established wooden-tip spray mass spectrometry (WTS-MS). These results showed that wooden-tip spray mass spectrometry would be useful for newborn screening of nicotine and cotinine in meconium with high reproducibility, speed, sensitivity, and specificity. Owing to the use of disposable wooden tips that involves no sample preparation and no chromatographic separation, our results show that wooden-tip spray mass spectrometry is a powerful tool for determination of nicotine in newborn meconium.
Collapse
Affiliation(s)
- Xinrong Wang
- Jiangxi Key Laboratory of Birth Defect Prevention and Control, Jiangxi Maternal and Child Health Hospital, Nanchang, China,Maternal and Child Health Hospital of Nanchang Medical College, Nanchang, China
| | - Mingyu Yang
- The First Clinical Medical School, Guangdong Medical University, Zhanjiang, China
| | - Hui Xiao
- Jiangxi Key Laboratory of Birth Defect Prevention and Control, Jiangxi Maternal and Child Health Hospital, Nanchang, China,Maternal and Child Health Hospital of Nanchang Medical College, Nanchang, China
| | - Danping Liu
- Jiangxi Key Laboratory of Birth Defect Prevention and Control, Jiangxi Maternal and Child Health Hospital, Nanchang, China,Maternal and Child Health Hospital of Nanchang Medical College, Nanchang, China
| | - Lu Pan
- Jiangxi Key Laboratory of Birth Defect Prevention and Control, Jiangxi Maternal and Child Health Hospital, Nanchang, China,Maternal and Child Health Hospital of Nanchang Medical College, Nanchang, China
| | - Liuyang Zhang
- Jiangxi Key Laboratory of Birth Defect Prevention and Control, Jiangxi Maternal and Child Health Hospital, Nanchang, China,Maternal and Child Health Hospital of Nanchang Medical College, Nanchang, China
| | - Yan Yang
- Jiangxi Key Laboratory of Birth Defect Prevention and Control, Jiangxi Maternal and Child Health Hospital, Nanchang, China,Maternal and Child Health Hospital of Nanchang Medical College, Nanchang, China
| | - Qing Lu
- Jiangxi Key Laboratory of Birth Defect Prevention and Control, Jiangxi Maternal and Child Health Hospital, Nanchang, China,Maternal and Child Health Hospital of Nanchang Medical College, Nanchang, China
| | - Yanqiu Liu
- Jiangxi Key Laboratory of Birth Defect Prevention and Control, Jiangxi Maternal and Child Health Hospital, Nanchang, China,Maternal and Child Health Hospital of Nanchang Medical College, Nanchang, China,*Correspondence: Bicheng Yang, ; Xiao Yang, ; Yanqiu Liu,
| | - Xiao Yang
- Jiangxi Key Laboratory of Birth Defect Prevention and Control, Jiangxi Maternal and Child Health Hospital, Nanchang, China,Maternal and Child Health Hospital of Nanchang Medical College, Nanchang, China,*Correspondence: Bicheng Yang, ; Xiao Yang, ; Yanqiu Liu,
| | - Bicheng Yang
- Jiangxi Key Laboratory of Birth Defect Prevention and Control, Jiangxi Maternal and Child Health Hospital, Nanchang, China,Maternal and Child Health Hospital of Nanchang Medical College, Nanchang, China,*Correspondence: Bicheng Yang, ; Xiao Yang, ; Yanqiu Liu,
| |
Collapse
|
19
|
Song Y, Zhang Y, Xie S, Song X. Screening and diagnosis of triple negative breast cancer based on rapid metabolic fingerprinting by conductive polymer spray ionization mass spectrometry and machine learning. Front Cell Dev Biol 2022; 10:1075810. [PMID: 36589750 PMCID: PMC9798417 DOI: 10.3389/fcell.2022.1075810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 11/22/2022] [Indexed: 12/23/2022] Open
Abstract
We present the use of conductive spray polymer ionization mass spectrometry (CPSI-MS) combined with machine learning (ML) to rapidly gain the metabolic fingerprint from 1 μl liquid extraction from the biopsied tissue of triple-negative breast cancer (TNBC) in China. The 76 discriminative metabolite markers are verified at the primary carcinoma site and can also be successfully tracked in the serum. The Lasso classifier featured with 15- and 22-metabolites detected by CPSI-MS achieve a sensitivity of 88.8% for rapid serum screening and a specificity of 91.1% for tissue diagnosis, respectively. Finally, the expression levels of their corresponding upstream enzymes and transporters have been initially confirmed. In general, CPSI-MS/ML serves as a cost-effective tool for the rapid screening, diagnosis, and precise characterization for the TNBC metabolism reprogramming in the clinical practice.
Collapse
Affiliation(s)
- Yaoyao Song
- Department of General Surgery, The Sixth Medical Center of Chinese PLA General Hospital, Beijing, China,Department of Burn and Plastic Surgery, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Yan Zhang
- Department of General Surgery, The Sixth Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Songhai Xie
- Department of Chemistry, Fudan University, Shanghai, China
| | - Xiaowei Song
- Department of Chemistry, Fudan University, Shanghai, China,*Correspondence: Xiaowei Song,
| |
Collapse
|
20
|
Ruan H, Xu C, Wang W, Li H. Hexapole-Assisted Continuous Atmospheric Pressure Interface for a High-Pressure Photoionization Miniature Ion Trap Mass Spectrometer. Anal Chem 2022; 94:17287-17294. [PMID: 36451554 DOI: 10.1021/acs.analchem.2c04274] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
Miniature mass spectrometers are powerful tools for on-site chemical analysis in the fields of homeland security, personal healthcare, and environmental monitoring. This study presents a novel hexapole-assisted continuous atmospheric pressure interface for a high-pressure photoionization miniature ion trap mass spectrometer (HA-HPPI-IT). Efficient ion transmission was achieved by combining radial focusing by an RF electric field and axial driving by gas flow, which was demonstrated by SIMION simulation and experimental verification. The pressure in the ionization-transmission chamber and the inner diameter of the skimmer were optimized, which helped in determining the number density of product ions and affected the ion transmission in the hexapole, respectively. After systematic optimizations, about 16-fold increase in signal intensity was achieved as the RF amplitude was varied from 140 to 400 Vpp, and a limit of detection of 1 ppbv was obtained. In addition, the HA-HPPI-IT exhibited high stability and the relative standard deviation was as low as 5.47%. Finally, the apparatus was applied for discovering the simulated spot for illicit drug synthesis by detecting toluene and propiophenone released to air and monitoring the evolutions of perchloroethylene residues from dry-cleaned clothes.
Collapse
Affiliation(s)
- Huiwen Ruan
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), 457 Zhongshan Road, Dalian116023, People's Republic of China.,University of Chinese Academy of Sciences, 19 Yuquan Road, Beijing100049, People's Republic of China.,Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian116023, People's Republic of China.,Dalian Engineering Research Center of Breath Diagnostic Technology, Dalian116023, People's Republic of China
| | - Chuting Xu
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), 457 Zhongshan Road, Dalian116023, People's Republic of China.,University of Chinese Academy of Sciences, 19 Yuquan Road, Beijing100049, People's Republic of China.,Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian116023, People's Republic of China.,Dalian Engineering Research Center of Breath Diagnostic Technology, Dalian116023, People's Republic of China
| | - Weiguo Wang
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), 457 Zhongshan Road, Dalian116023, People's Republic of China.,Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian116023, People's Republic of China.,Dalian Engineering Research Center of Breath Diagnostic Technology, Dalian116023, People's Republic of China
| | - Haiyang Li
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), 457 Zhongshan Road, Dalian116023, People's Republic of China.,Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian116023, People's Republic of China.,Dalian Engineering Research Center of Breath Diagnostic Technology, Dalian116023, People's Republic of China
| |
Collapse
|
21
|
Lee CW, Su H, Shiea J. Potential applications and challenges of novel ambient ionization mass spectrometric techniques in the emergency care for acute poisoning. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
22
|
Zhou W, Pawliszyn J. Coated Blade Spray with a Barrier: Improving Negative Electrospray Ionization and Sample Preparation. Anal Chem 2022; 94:15879-15886. [DOI: 10.1021/acs.analchem.2c04003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, OntarioN2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, OntarioN2L 3G1, Canada
| |
Collapse
|
23
|
Zhou W, Nazdrajić E, Pawliszyn J. Rapid Screening and Quantitation of Drugs of Abuse by Both Positive and Negative Modes via Coated Blade Spray-Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:1187-1193. [PMID: 35609124 DOI: 10.1021/jasms.2c00040] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Solid-phase microextraction (SPME)-direct mass spectrometry (MS) has proven to be an efficient tool for the rapid screening and quantitation of target compounds at trace levels. However, it is challenging to perform screening using both positive and negative modes in one analytical run without compromising scanning speed and detection sensitivity. To take advantage of the special geometry of a coated blade spray (CBS) blade, which consists of two flat sides coated with the same SPME coating, we developed a CBS-MS method that enables desorption and ionization to be performed in positive ionization mode on one side of a coated blade and negative ionization mode on the other side of the same blade. By simply flipping the blade 180°, MS analysis in both ionization modes on different sides can be completed in 40 s. Combining this approach with an automated Concept 96-blade-based SPME system allowed analysis for one sample in positive and negative modes to be completed in less than 1 min. The workflow was optimized by using a biocompatible polyacrylonitrile as an undercoating layer and a binder of polyacrylonitrile/hydrophilic-lipophilic balance (HLB) particles, which enabled the rapid analysis of 20 drugs of abuse in saliva samples in both positive and negative modes. The proposed method provided low limits of quantification (between 0.005 and 10 ng/mL), with calibration linear correlation coefficients ⩾ 0.9925, accuracy between 72% and 126%, and relative precision < 15% for three validation points.
Collapse
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Emir Nazdrajić
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
24
|
Pursell ME, Sharif D, DeBastiani A, Li C, Majuta S, Li P, Valentine SJ. Development of cVSSI-APCI for the Improvement of Ion Suppression and Matrix Effects in Complex Mixtures. Anal Chem 2022; 94:9226-9233. [PMID: 35729103 PMCID: PMC9260805 DOI: 10.1021/acs.analchem.1c05136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The new ionization technique termed vibrating sharp-edge spray ionization (cVSSI) has been coupled with corona discharge to investigate atmospheric pressure chemical ionization (APCI) capabilities. The optimized source was evaluated for its ability to enhance ion signal intensity, overcome matrix effects, and limit ion suppression. The results have been compared with state-of-the-art ESI source performance as well as a new APCI-like source. In methanol, the ion signal intensity increased 10-fold and >10-fold for cocaine and the suppressed analytes, respectively. The ability to overcome ion suppression was improved from 2-fold to 16-fold for theophylline and vitamin D2, respectively. For aqueous samples, ion signal levels increased by two orders of magnitude for all analytes. In both solvent systems, the signal-to-noise ratios also increased for all suppressed analytes. One example of the characterization of low-ionizing (by ESI or cVSSI alone) species in the presence of high-ionizing species by direct analysis from a cotton swab is presented. The work is discussed with respect to the advantages of cVSSI-APCI for direct, in situ, and field analyses.
Collapse
Affiliation(s)
- Madison E. Pursell
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Daud Sharif
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Anthony DeBastiani
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Chong Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Sandra Majuta
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Stephen J. Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| |
Collapse
|
25
|
Marasco Júnior CA, Edwards ME, Lamarca RS, Sobreira TJP, Caterino JM, Hains DS, Schwaderer AL, Lima Gomes PCFD, Ferreira CR. Suspect screening of exogenous compounds using multiple reaction screening (MRM) profiling in human urine samples. J Chromatogr B Analyt Technol Biomed Life Sci 2022; 1201-1202:123290. [PMID: 35588643 PMCID: PMC10566365 DOI: 10.1016/j.jchromb.2022.123290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Revised: 04/14/2022] [Accepted: 05/07/2022] [Indexed: 11/25/2022]
Abstract
Thousands of chemical compounds produced by industry are dispersed in the human environment widely enough to reach the world population, and the introduction of new chemicals constantly occurs. As new synthetic molecules emerge, rapid analytical workflows for screening possible presence of exogenous compounds in biofluids can be useful as a first pass analysis to detect chemical exposure and guide the development and application of more elaborate LC-MS/MS methods for quantification. In this study, a suspect screening workflow using the multiple reaction monitoring (MRM) profiling method is proposed as a first pass exploratory technique to survey selected exogenous molecules in human urine samples. The workflow was applied to investigate 12 human urine samples using 310 MRMs related to the chemical functionalities of 87 exogenous compounds present in the METLIN database and reported in the literature. A total of 11 MRMs associated with five different compounds were detected in the samples. Product ion scans for the precursor ions of the selected MRMs were acquired as a further identification step for these chemicals. The suspect screening results suggested the presence of five exogenous compounds in the human urine samples analyzed, namely metformin, metoprolol, acetaminophen, paraxanthine and acrylamide. LC-MS/MS was applied as a last step to confirm these results, and the presence of four out of the five targets selected by MRM profiling were corroborated, indicating that this workflow can support the selection of suspect compounds to screen complex samples and guide more time-consuming and specific quantification analyses.
Collapse
Affiliation(s)
- César A Marasco Júnior
- National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, São Paulo State University (UNESP), P.O. Box 355, 14800-060 Araraquara, São Paulo, Brazil; Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
| | - Madison E Edwards
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
| | - Rafaela S Lamarca
- National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, São Paulo State University (UNESP), P.O. Box 355, 14800-060 Araraquara, São Paulo, Brazil
| | - Tiago J P Sobreira
- Bindley Bioscience Center, Purdue University, West Lafayette, IN 47907, USA
| | - Jeffrey M Caterino
- Department of Emergency Medicine, The Ohio State University, Columbus, OH 43210, USA
| | - David S Hains
- Department of Pediatrics, Indiana University, Indianapolis, IN 43202, USA
| | | | - Paulo Clairmont F de Lima Gomes
- National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, São Paulo State University (UNESP), P.O. Box 355, 14800-060 Araraquara, São Paulo, Brazil.
| | - Christina R Ferreira
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA; Bindley Bioscience Center, Purdue University, West Lafayette, IN 47907, USA.
| |
Collapse
|
26
|
Su H, Huang MZ, Shiea J, Lee CW. Thermal desorption ambient ionization mass spectrometry for emergency toxicology. MASS SPECTROMETRY REVIEWS 2022:e21784. [PMID: 35603997 DOI: 10.1002/mas.21784] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 12/17/2021] [Accepted: 01/21/2022] [Indexed: 06/15/2023]
Abstract
In the emergency department, it is important to rapidly identify the toxic substances that have led to acute poisoning because different toxicants or toxins cause poisoning through different mechanisms, requiring disparate therapeutic strategies and precautions against contraindicating actions, and diverse directions of clinical course monitoring and prediction of prognosis. Ambient ionization mass spectrometry, a state-of-the-art technology, has been proved to be a fast, accurate, and user-friendly tool for rapidly identifying toxicants like residual pesticides on fruits and vegetables. In view of this, developing an analytical platform that explores the application of such a cutting-edge technology in a novel direction has been initiated a research program, namely, the rapid identification of toxic substances which might have caused acute poisoning in patients who visit the emergency department and requires an accurate diagnosis for correct clinical decision-making to bring about corresponding data-guided management. This review includes (i) a narrative account of the breakthrough in emergency toxicology brought about by the advent of ambient ionization mass spectrometry and (ii) a thorough discussion about the clinical implications and technical limitations of such a promising innovation for promoting toxicological tests from tier two-level to tier one level.
Collapse
Affiliation(s)
- Hung Su
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Min-Zong Huang
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Jentaie Shiea
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University, Kaohsiung, Taiwan
- Research Center for Environmental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Chi-Wei Lee
- Institute of Medical Science and Technology, National Sun Yat-Sen University, Kaohsiung, Taiwan
| |
Collapse
|
27
|
Roadmap for large-scale implementation of point-of-care testing in primary care in Central and Eastern European countries: the Hungarian experience. Prim Health Care Res Dev 2022; 23:e26. [PMID: 35445652 PMCID: PMC9112671 DOI: 10.1017/s1463423622000159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Objective: The aim of this study is to give a broad overview of the international best practices regarding the implementation of point-of-care testing (POCT) in primary care (PC) setting and to highlight the facilitators and barriers for widespread national uptake. The study focuses on the managerial and organizational side of POCT, offering a roadmap for implementation as well as highlighting the most important requirements needed to unlock the clinical and economical potential of POCT in the Hungarian healthcare system. Methods: We conducted an English language scoping literature review between January 2012 and June 2021 to assess the recent trends of POCT implementation in developed countries. Our research focuses on the recent publications of several European and Anglo-Saxon countries where POCT utilization is common. In parallel, we reviewed the Hungarian regulatory framework, ongoing governmental legislation, and strategies influencing the POCT dissemination in the Hungarian PC sector. Results: Among the possible POCT usage in PC, we identified several clinically relevant devices and tests (C-reactive protein, urine, blood glucose, D-dimer, prothrombin time) important in screening and early detection of morbidities representing high disease burden. Based on international literature, general practitioners (GPs) are interested in the shortened diagnostic times, portable devices, and better doctor–patient relations made possible by POCT. There are several concerns, however, regarding initial and operational costs and reimbursement, limited scientific evidence about quality and safety, unclear regulations on quality validation of tests, as well as managerial aspects like PC staff training and IT integration at the GP level. Conclusion: As our review highlights, there is considerable interest among GPs to implement POCT as it has the potential to improve quality of care; however, there are many obstacles to overcome before widespread uptake. Further investigation is recommended to elaborate management and quality insurance background and to develop appropriate regulatory framework and financial scheme for GP practices. Preferably this work should involve the local practicing GPs to better tailor the implementation roadmap to country-specific details.
Collapse
|
28
|
Mainero Rocca L, L'Episcopo N, Gordiani A, Staderini A. Direct multiclass desorption electrospray ionization-tandem mass spectrometry method for the analysis of sleep inducers and ototoxic drugs in dried blood spots. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9265. [PMID: 35128730 DOI: 10.1002/rcm.9265] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 02/01/2022] [Accepted: 02/01/2022] [Indexed: 06/14/2023]
Abstract
RATIONALE An unconventional and innovative approach for the quantitative determination of 11 ototoxic and narcoleptic drugs in whole blood is described. The multiclass method allows the inclusion of the most widespread drugs on the market (antihistamines, antidepressants, antihypertensives, anxiolytics, opioids, Z-drugs) responsible for 10% of occupational accidents. METHODS The developed procedure involved the use of the desorption electrospray ionization (DESI) interface for the direct analysis of dried blood spots (DBS). All the issues strictly connected to the chemical-physical characteristics of DBS and DESI (sample inhomogeneity, DBS support, DESI geometry and solvent) were carefully evaluated and innovative strategies were applied. Haematocrit was managed using a small and measured volume of blood (2 μL) with analysis of the entire DBS. RESULTS The proposed method was fully validated in terms of limits of detection, limits of quantitation (LOQs; between 60 pg/mm2 and 1.6 ng/mm2 ), linearity (one order of magnitude starting from LOQs) and inter- and intra-day precision (on three levels, with relative standard deviation values not exceeding 17%). Accuracy was calculated by comparison with an ultrahigh-performance liquid chromatography-tandem mass spectrometry method (suitable also as a confirmatory method). CONCLUSIONS Results showed a surprising sensitivity, demonstrating that this procedure could be suitable for applications in various fields, e.g. forensic analysis. Moreover, as a collateral benefit, it was discovered that the method is able to analyse very light traces left on plastic and glass surfaces by detached dried blood.
Collapse
Affiliation(s)
- Lucia Mainero Rocca
- Chemical Agents Laboratory, Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, Italian Workers' Compensation Authority (INAIL), Monte Porzio Catone, Rome, Italy
| | - Nunziata L'Episcopo
- Chemical Agents Laboratory, Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, Italian Workers' Compensation Authority (INAIL), Monte Porzio Catone, Rome, Italy
| | - Andrea Gordiani
- Chemical Agents Laboratory, Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, Italian Workers' Compensation Authority (INAIL), Monte Porzio Catone, Rome, Italy
| | - Alessandro Staderini
- Chemical Agents Laboratory, Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, Italian Workers' Compensation Authority (INAIL), Monte Porzio Catone, Rome, Italy
| |
Collapse
|
29
|
Zhou X, Zhang W, Ouyang Z. Recent advances in on-site mass spectrometry analysis for clinical applications. Trends Analyt Chem 2022; 149:116548. [PMID: 35125564 PMCID: PMC8802081 DOI: 10.1016/j.trac.2022.116548] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
In recent years, mass spectrometry (MS) is increasingly attracting interests for clinical applications, which also calls for technical innovations to make a transfer of MS from conventional analytical laboratories to clinics. The system design and analysis procedure should be friendly for novice users and appliable for on-site clinical diagnosis. In addition, the analysis result should be auto-interpreted and reported in formats much simpler than mass spectra. This motivates new ideas for developments in all the aspects of MS. In this review, we report recent advances of direct sampling ionization and miniature MS system, which have been developed targeting clinical and even point-of-care analysis. We also discuss the trend of the development and provide perspective on the technical challenges raised by diseases such as coronavirus SARS-CoV-2.
Collapse
Affiliation(s)
- Xiaoyu Zhou
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China
| | - Wenpeng Zhang
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China
| | - Zheng Ouyang
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China
| |
Collapse
|
30
|
Wang J, Li C, Li P. A Small Footprint and Robust Interface for Solid Phase Microextraction and Mass Spectrometry Based on Vibrating Sharp-Edge Spray Ionization. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:304-314. [PMID: 35040644 PMCID: PMC9014482 DOI: 10.1021/jasms.1c00305] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Combining solid phase microextraction (SPME) and mass spectrometry (MS) analysis has become increasingly important to many bioanalytical, environmental, and forensic applications due to its simplicity, rapid analysis, and capability of reducing matrix effects for complex samples. To further promote the adoption of SPME-MS based analysis and expand its application scope calls for efficient and convenient interfaces that couple the SPME sample handling with the efficient analyte ionization for MS. Here, we report a novel interface that integrates both the desorption and the ionization steps in one device based on the capillary vibrating sharp-edge spray ionization (cVSSI) method. We demonstrated that the cVSSI is capable of nebulizing liquid samples in a pulled-tip glass capillary with a battery powered function generator. The cVSSI device allows the insertion of a SPME probe into the spray capillary for desorption and then direct nebulization of the desorption solvent in situ. With the integrated interface, we have demonstrated rapid MS analysis of drug compounds from serum samples. Quantitative determination of various drug compounds including metoprolol, pindolol, acebutolol, oxprenolol, capecitabine, and irinotecan was achieved with good linearity (R2 = 0.97-0.99) and limit of detection ranging from 0.25 to 0.59 ng/mL without using a high voltage source. Only 3.5 μL of desorption solvent and 3 min desorption time were needed for the present method. Overall, we demonstrated a portable SPME-MS interface featuring high sensitivity, short analysis time, small footprint, and low cost, which makes it an attractive method for many applications requiring sample cleanup including drug compound monitoring, environmental sample analysis, and forensic sample analysis.
Collapse
Affiliation(s)
- Jing Wang
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Chong Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| |
Collapse
|
31
|
Spherical Sampler Probes Enhance the Robustness of Ambient Ionization Mass Spectrometry for Rapid Drugs Screening. Molecules 2022; 27:molecules27030945. [PMID: 35164211 PMCID: PMC8840626 DOI: 10.3390/molecules27030945] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 01/26/2022] [Accepted: 01/28/2022] [Indexed: 02/06/2023] Open
Abstract
Ambient ionization mass spectrometry has become one of the most promising approaches for rapid and high-throughput screening of small molecules in complex biological matrices for emergency medicine, forensics, and food and agriculture applications. The simple procedures for sample collection and ionization without additional pretreatment are vital in these fields. Many efforts have been devoted to modifying various ambient ionization techniques to simplify the procedures and improve the robustness and sensitivity of the methods. Here, we demonstrate the implementation of rigid spherical sampler probes to improve the robustness of touch spray ionization mass spectrometry. The sphericity of the probes increases the stability of the cone-jet mode of electrospray, reduces the requirements for fine positioning of a sampler in the ion source, and decreases the possibility of corona discharge occurrence. The utilization of spherical sampler probes allows fast, non-invasive sampling, followed by rapid analysis for various drugs of different chemical classes in complex biological matrices, such as the whole blood or sebum collected from the skin surface. The linearity of the analytical signal response from drug concentration confirms the possibility of creating a simple semiquantitative method for small molecules monitoring using spherical sampler probes.
Collapse
|
32
|
Yang Y, Wang W, Liu H, Tong L, Mu X, Chen Z, Tang B. Sensitive Quantification of MicroRNA in Blood through Multi‐amplification Toehold‐Mediated DNA‐Strand‐Displacement Paper‐Spray Mass Spectrometry (TSD‐PS MS). Angew Chem Int Ed Engl 2022. [DOI: 10.1002/ange.202113051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Yanmei Yang
- College of Chemistry Chemical Engineering and Materials Science Key Laboratory of Molecular and Nano Probes Ministry of Education Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong Institute of Molecular and Nano Science Shandong Normal University Jinan 250014 P. R. China
| | - Weiqing Wang
- College of Chemistry Chemical Engineering and Materials Science Key Laboratory of Molecular and Nano Probes Ministry of Education Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong Institute of Molecular and Nano Science Shandong Normal University Jinan 250014 P. R. China
| | - Huimin Liu
- College of Chemistry Chemical Engineering and Materials Science Key Laboratory of Molecular and Nano Probes Ministry of Education Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong Institute of Molecular and Nano Science Shandong Normal University Jinan 250014 P. R. China
| | - Lili Tong
- College of Chemistry Chemical Engineering and Materials Science Key Laboratory of Molecular and Nano Probes Ministry of Education Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong Institute of Molecular and Nano Science Shandong Normal University Jinan 250014 P. R. China
| | - Xiaoyan Mu
- College of Chemistry Chemical Engineering and Materials Science Key Laboratory of Molecular and Nano Probes Ministry of Education Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong Institute of Molecular and Nano Science Shandong Normal University Jinan 250014 P. R. China
| | - Zhenzhen Chen
- College of Chemistry Chemical Engineering and Materials Science Key Laboratory of Molecular and Nano Probes Ministry of Education Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong Institute of Molecular and Nano Science Shandong Normal University Jinan 250014 P. R. China
| | - Bo Tang
- College of Chemistry Chemical Engineering and Materials Science Key Laboratory of Molecular and Nano Probes Ministry of Education Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong Institute of Molecular and Nano Science Shandong Normal University Jinan 250014 P. R. China
| |
Collapse
|
33
|
Wilson S, Steele S, Adeli K. Innovative technological advancements in laboratory medicine: Predicting the lab of the future. BIOTECHNOL BIOTEC EQ 2022. [DOI: 10.1080/13102818.2021.2011413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/09/2022] Open
Affiliation(s)
- Siobhan Wilson
- Clinical Biochemistry, Pediatric Laboratory Medicine and Molecular Medicine, Research Institute, The Hospital for Sick Children, Toronto, ON, Canada
- Department of Laboratory Medicine & Pathobiology, Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| | - Shannon Steele
- Clinical Biochemistry, Pediatric Laboratory Medicine and Molecular Medicine, Research Institute, The Hospital for Sick Children, Toronto, ON, Canada
| | - Khosrow Adeli
- Clinical Biochemistry, Pediatric Laboratory Medicine and Molecular Medicine, Research Institute, The Hospital for Sick Children, Toronto, ON, Canada
- Department of Laboratory Medicine & Pathobiology, Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
34
|
Liu B, Tang W, Li H, Liu R, Dong F, Guo Y, Li J, Hou K. Point-of-care detection of sevoflurane anesthetics in exhaled breath using a miniature TOFMS for diagnosis of postoperative agitation symptoms in children. Analyst 2022; 147:2484-2493. [DOI: 10.1039/d2an00479h] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
A miniature TOFMS with MEPEI has been developed for POC diagnosis of postoperative agitation symptoms, and can analyze sevoflurane by direct sampling. The risk is high when the sevoflurane in the exhaled breath is higher than 500 ppmv.
Collapse
Affiliation(s)
- Bing Liu
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao 266237, People's Republic of China
| | - Wenxi Tang
- Department of Anesthesiology, Qilu Hospital (Qingdao), Cheeloo College of Medicine, Shandong University, Qingdao, 758 Hefei Road, Qingdao 266035, People's Republic of China
| | - Hang Li
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People's Republic of China
| | - Ruidong Liu
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao 266237, People's Republic of China
| | - Fengshuo Dong
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao 266237, People's Republic of China
| | - Yingzhe Guo
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao 266237, People's Republic of China
| | - Jianjun Li
- Department of Anesthesiology, Qilu Hospital (Qingdao), Cheeloo College of Medicine, Shandong University, Qingdao, 758 Hefei Road, Qingdao 266035, People's Republic of China
| | - Keyong Hou
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao 266237, People's Republic of China
| |
Collapse
|
35
|
Chen L, Ghiasvand A, Sanz Rodriguez E, Innis PC, Paull B. Nanomaterial-assisted thread-based isotachophoresis with on-thread solute trapping. Analyst 2022; 147:1944-1951. [DOI: 10.1039/d2an00287f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This research describes a nanomaterial-assisted TB-ITP setup for the clean-up, preconcentration, and trapping of alkaloids in biological fluids, followed by their on-thread DESI-MS determination.
Collapse
Affiliation(s)
- Liang Chen
- Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
- ARC Centre of Excellence for Electromaterials Sciences (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Alireza Ghiasvand
- Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
- ARC Centre of Excellence for Electromaterials Sciences (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
- Department of Chemistry, Lorestan University, Khorramabad, Iran
| | - Estrella Sanz Rodriguez
- Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Peter C. Innis
- ARC Centre of Excellence for Electromaterials Science (ACES), Intelligent Polymer Research Institute, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Brett Paull
- Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
- ARC Centre of Excellence for Electromaterials Sciences (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| |
Collapse
|
36
|
Yang Y, Wang W, Liu H, Tong L, Mu X, Chen Z, Tang B. Sensitive Quantification of MicroRNA in Blood through Multi-amplification Toehold-Mediated DNA-Strand-Displacement Paper-Spray Mass Spectrometry (TSD-PS MS). Angew Chem Int Ed Engl 2021; 61:e202113051. [PMID: 34881475 DOI: 10.1002/anie.202113051] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Indexed: 11/07/2022]
Abstract
Accurate quantification of disease-signature microRNAs (miRNAs) in biomedical samples is in high demand for clinical diagnosis but still challenging because of low miRNAs abundance and complicating interferences in the milieus. Here, we report a multi-amplification strategy for blood miRNAs analysis based on paper-spray mass spectrometry (PS MS). A toehold-mediated DNA-strand-displacement reaction (TSD) is employed to amplify the signal chain and to ensure the specificity. The signal chain is then cleaved by UV to release signal molecules for detection. Moreover, paper spray can efficiently filter out the interfering substances in blood and further enhances the detecting sensitivity. This concept is successfully demonstrated in the prototype detection of a cancer biomarker miRNA-141 in blood and serum. The proposed TSD-PS MS approach provides an efficient way for sensitive detection of oligonucleotides with low concentration in complicating milieus.
Collapse
Affiliation(s)
- Yanmei Yang
- Shandong Normal University, College of Chemistry, 80, CHINA
| | - Weiqing Wang
- Shandong Normal University, College of Chemistry, CHINA
| | - Huimin Liu
- Shandong Normal University, College of Chemistry, CHINA
| | - Lili Tong
- Shandong Normal University, College of Chmistry, CHINA
| | - Xiaoyan Mu
- Shandong Normal University, College of Chemistry, CHINA
| | - Zhenzhen Chen
- Shandong Normal University, College of Chemistry, CHINA
| | - Bo Tang
- Shandong Normal University, Chemistry, No.88 Wenhua East Road, 250014, Jinan, CHINA
| |
Collapse
|
37
|
Jiao B, Ye H, Liu X, Bu J, Wu J, Zhang W, Zhang Y, Ouyang Z. Handheld Mass Spectrometer with Intelligent Adaptability for On-Site and Point-of-Care Analysis. Anal Chem 2021; 93:15607-15616. [PMID: 34780167 DOI: 10.1021/acs.analchem.1c02508] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The development of miniature mass spectrometry (MS) systems with simple analysis procedures is important for the transition of applying MS analysis outside traditional analytical laboratories. Here, we present Mini 14, a handheld MS instrument with disposable sample cartridges designed based on the ambient ionization concept for intrasurgical tissue analysis and surface analysis. The instrumentation architecture consists of a single-stage vacuum chamber with a discontinuous atmospheric interface and a linear ion trap. A major effort in this study for technical advancement is on making handheld MS systems capable of automatically adapting to complex conditions for in-field analysis. Machine learning is used to establish the model for autocorrecting the mass offsets in the mass scale due to temperature variations and a new strategy is developed to extend the dynamic concentration range for analysis. Mini 14 weighs 12 kg and can operate on battery power for more than 3 h. The mass range exceeds m/z 2000, and the full peak width at half-maximum is Δm/z 0.4 at a scanning speed of 700 Th/s. The direct analysis of human brain tissue for identifying glioma associated with isocitrate dehydrogenase mutations has been achieved and a limit of detection of 5 ng/mL has been obtained for analyzing illicit drugs in blood.
Collapse
Affiliation(s)
- Bin Jiao
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China
| | - Huimin Ye
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China
| | - Xinwei Liu
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China
| | - Jiexun Bu
- PURSPEC Technologies Inc., Beijing 100084, China
| | - Junhan Wu
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China
| | - Wenpeng Zhang
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China
| | - Yunfeng Zhang
- Institute of Forensic Science of China, Ministry of Public Security, Beijing 100038, China
| | - Zheng Ouyang
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China
| |
Collapse
|
38
|
Wang J, Valentine SJ, Li P. Integrated sample desalting, enrichment, and ionization on an omniphobic glass slide for direct mass spectrometry analysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35:e9179. [PMID: 34363417 DOI: 10.1002/rcm.9179] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Revised: 08/02/2021] [Accepted: 08/04/2021] [Indexed: 06/13/2023]
Abstract
RATIONALE Direct and rapid mass spectrometry (MS) analysis is desired for many applications including environmental monitoring, forensic analysis, chemical and biological defense, and point-of-care testing. However, sample pretreatment is often necessary for analyzing targets from complex matrices using MS due to ion suppression. To achieve rapid MS analysis calls for simple and efficient solutions for sample processing and ionization. Here, a simple sample pretreatment and ionization workflow is reported, which achieves sample desalting, enrichment, and ionization on a single glass slide. METHODS Desalting is achieved based on crystallization and re-dissolution-induced spontaneous separation of analytes and salt. Efficient sample enrichment is achieved during the crystallization process by modifying the glass surface with an omniphobic coating. Finally, vibrating sharp-edge spray ionization is employed to ionize the target molecules directly on the glass slide. Thus, all the necessary sample operations prior to MS analysis are completed on the sample glass slide. RESULTS Efficient sample enrichment on the omniphobic glass slide is first visualized using food dyes. The benefits of the desalting and enrichment steps for detecting macrolide antibiotics in 1× phosphate buffered saline (PBS) solutions are demonstrated by comparing samples with different treatment procedures. Finally, quantification of macrolide antibiotics from PBS and serum samples is demonstrated. A linear range between 2 nM and 10 μM has been achieved for the serum sample with a limit of detection of 1 nM. CONCLUSIONS A simple, flexible, low-cost, and highly integrated workflow for detecting target molecules from complex matrices using MS is demonstrated. This method will be valuable to many applications that require rapid and efficient MS analysis of complex samples.
Collapse
Affiliation(s)
- Jing Wang
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Stephen J Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| |
Collapse
|
39
|
Cai SH, Di D, Yuan ZC, Chen W, Hu B. Paper-in-Facemask Device for Direct Mass Spectrometry Analysis of Human Respiratory Aerosols and Environmental Exposures via Wearable Continuous-Flow Adsorptive Sampling: A Proof-of-Concept Study. Anal Chem 2021; 93:13743-13748. [PMID: 34609849 DOI: 10.1021/acs.analchem.1c03406] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Facemasks are considered safe and wearable devices that cover the human mouth and nose for filtering exhaled aerosols and inhaled environmental exposures; various chemical and environmental residues thus can remain in facemasks. Therefore, direct analysis of residues in facemasks can be used to investigate the wearer's health and behavior. Here, we developed a simple paper-in-facemask sampling method for adsorbing a wearer's respiratory aerosol and environmental exposures by fixing paper strips at the outside and inside surfaces of facemasks, and the paper strips were then analyzed by paper spray mass spectrometry (PSMS) for directly detecting adsorbed analytes without any sample pretreatment. The applicability of this device was demonstrated by directly analyzing exhaled aerosolized saliva, breath metabolites, and inhalable environmental exposures. The technical aspects, including sampling time, sampling position, paper property, and spray solvent, were investigated. The sampling process was revealed to involve a continuous-flow adsorptive mechanism. These findings motivated us to extend this work and build a wearable sampling device that is capable of simultaneously monitoring both exhaled and inhaled biomarkers in situ to investigate human health and environmental exposure. This work highlights that facemasks are promising platforms for aerosol collection and direct MS analysis, which is expected to be a promising method for monitoring human health, diseases, and behaviors.
Collapse
Affiliation(s)
- Shen-Hui Cai
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| | - Dandan Di
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| | - Zi-Cheng Yuan
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| | - Weini Chen
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| | - Bin Hu
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| |
Collapse
|
40
|
Pruski P, Correia GDS, Lewis HV, Capuccini K, Inglese P, Chan D, Brown RG, Kindinger L, Lee YS, Smith A, Marchesi J, McDonald JAK, Cameron S, Alexander-Hardiman K, David AL, Stock SJ, Norman JE, Terzidou V, Teoh TG, Sykes L, Bennett PR, Takats Z, MacIntyre DA. Direct on-swab metabolic profiling of vaginal microbiome host interactions during pregnancy and preterm birth. Nat Commun 2021; 12:5967. [PMID: 34645809 PMCID: PMC8514602 DOI: 10.1038/s41467-021-26215-w] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Accepted: 09/23/2021] [Indexed: 11/13/2022] Open
Abstract
The pregnancy vaginal microbiome contributes to risk of preterm birth, the primary cause of death in children under 5 years of age. Here we describe direct on-swab metabolic profiling by Desorption Electrospray Ionization Mass Spectrometry (DESI-MS) for sample preparation-free characterisation of the cervicovaginal metabolome in two independent pregnancy cohorts (VMET, n = 160; 455 swabs; VMET II, n = 205; 573 swabs). By integrating metataxonomics and immune profiling data from matched samples, we show that specific metabolome signatures can be used to robustly predict simultaneously both the composition of the vaginal microbiome and host inflammatory status. In these patients, vaginal microbiota instability and innate immune activation, as predicted using DESI-MS, associated with preterm birth, including in women receiving cervical cerclage for preterm birth prevention. These findings highlight direct on-swab metabolic profiling by DESI-MS as an innovative approach for preterm birth risk stratification through rapid assessment of vaginal microbiota-host dynamics.
Collapse
Affiliation(s)
- Pamela Pruski
- Division of Systems Medicine, Department of Metabolism, Digestion and Reproduction, Faculty of Medicine Imperial College London, London, UK
| | - Gonçalo D S Correia
- Division of Systems Medicine, Department of Metabolism, Digestion and Reproduction, Faculty of Medicine Imperial College London, London, UK
- National Phenome Centre, Imperial College London, London, UK
| | - Holly V Lewis
- March of Dimes Prematurity Research Centre at Imperial College London, London, UK
- Imperial College Parturition Research Group, Institute of Reproductive and Developmental Biology, Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
- Queen Charlotte's & Chelsea Hospital, Imperial College London, London, UK
| | - Katia Capuccini
- March of Dimes Prematurity Research Centre at Imperial College London, London, UK
- Imperial College Parturition Research Group, Institute of Reproductive and Developmental Biology, Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
| | - Paolo Inglese
- Division of Systems Medicine, Department of Metabolism, Digestion and Reproduction, Faculty of Medicine Imperial College London, London, UK
- National Phenome Centre, Imperial College London, London, UK
| | - Denise Chan
- March of Dimes Prematurity Research Centre at Imperial College London, London, UK
- Imperial College Parturition Research Group, Institute of Reproductive and Developmental Biology, Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
- Queen Charlotte's & Chelsea Hospital, Imperial College London, London, UK
| | - Richard G Brown
- Imperial College Parturition Research Group, Institute of Reproductive and Developmental Biology, Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
- Queen Charlotte's & Chelsea Hospital, Imperial College London, London, UK
| | - Lindsay Kindinger
- Imperial College Parturition Research Group, Institute of Reproductive and Developmental Biology, Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
- Elizabeth Garrett Anderson Institute for Women's Health, University College London, London, UK
| | - Yun S Lee
- March of Dimes Prematurity Research Centre at Imperial College London, London, UK
- Imperial College Parturition Research Group, Institute of Reproductive and Developmental Biology, Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
| | - Ann Smith
- Faculty of Health and Applied Sciences, University West of England, Bristol, UK
| | - Julian Marchesi
- Division of Systems Medicine, Department of Metabolism, Digestion and Reproduction, Faculty of Medicine Imperial College London, London, UK
- March of Dimes Prematurity Research Centre at Imperial College London, London, UK
| | - Julie A K McDonald
- MRC Centre for Molecular Bacteriology and Infection, Imperial College London, London, UK
| | - Simon Cameron
- Division of Systems Medicine, Department of Metabolism, Digestion and Reproduction, Faculty of Medicine Imperial College London, London, UK
- School of Biological Sciences, Institute for Global Food Security, Queen's University Belfast, Belfast, UK
| | - Kate Alexander-Hardiman
- Division of Systems Medicine, Department of Metabolism, Digestion and Reproduction, Faculty of Medicine Imperial College London, London, UK
| | - Anna L David
- Elizabeth Garrett Anderson Institute for Women's Health, University College London, London, UK
| | - Sarah J Stock
- MRC Centre for Reproductive Health, University of Edinburgh, Edinburgh, UK
| | - Jane E Norman
- MRC Centre for Reproductive Health, University of Edinburgh, Edinburgh, UK
- Faculty of Health Sciences, University of Bristol, Bristol, UK
| | - Vasso Terzidou
- March of Dimes Prematurity Research Centre at Imperial College London, London, UK
- Imperial College Parturition Research Group, Institute of Reproductive and Developmental Biology, Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
- Chelsea & Westminster Hospital, NHS Trust, London, UK
| | - T G Teoh
- St Mary's Hospital, Imperial College Healthcare NHS Trust, London, UK
| | - Lynne Sykes
- March of Dimes Prematurity Research Centre at Imperial College London, London, UK
- Imperial College Parturition Research Group, Institute of Reproductive and Developmental Biology, Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
- Queen Charlotte's & Chelsea Hospital, Imperial College London, London, UK
| | - Phillip R Bennett
- March of Dimes Prematurity Research Centre at Imperial College London, London, UK
- Imperial College Parturition Research Group, Institute of Reproductive and Developmental Biology, Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
- Queen Charlotte's & Chelsea Hospital, Imperial College London, London, UK
- Tommy's National Centre for Miscarriage Research, Imperial College London, London, UK
| | - Zoltan Takats
- Division of Systems Medicine, Department of Metabolism, Digestion and Reproduction, Faculty of Medicine Imperial College London, London, UK.
- National Phenome Centre, Imperial College London, London, UK.
- March of Dimes Prematurity Research Centre at Imperial College London, London, UK.
| | - David A MacIntyre
- March of Dimes Prematurity Research Centre at Imperial College London, London, UK.
- Imperial College Parturition Research Group, Institute of Reproductive and Developmental Biology, Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK.
- Tommy's National Centre for Miscarriage Research, Imperial College London, London, UK.
| |
Collapse
|
41
|
Batista PR, Penna TC, Ducati LC, Correra TC. p-Aminobenzoic acid protonation dynamics in an evaporating droplet by ab initio molecular dynamics. Phys Chem Chem Phys 2021; 23:19659-19672. [PMID: 34524295 DOI: 10.1039/d1cp01495a] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Protonation equilibria are known to vary from the bulk to microdroplet conditions, which could induce many chemical and physical phenomena. Protonated p-aminobenzoic acid (PABA + H+) can be considered a model for probing the protonation dynamics in an evaporating droplet, as its protonation equilibrium is highly dependent on the formation conditions from solution via atmospheric pressure ionization sources. Experiments using diverse experimental techniques have shown that protic solvents allow formation of the O-protomer (PABA protonated in the carboxylic acid group) stable in the gas phase, while aprotic solvents yield the N-protomer (protonated in the amino group) that is the most stable protomer in solution. In this work, we explore the protonation equilibrium of PABA solvated by different numbers of water molecules (n = 0 to 32) using ab initio molecular dynamics. For n = 8-32, the protonation is either at the NH2 group or in the solvent network. The solvent network interacts with the carboxylic acid group, but there is no complete proton transfer to form the O-protomer. For smaller clusters, however, solvent-mediated proton transfers to the carboxylic acid were observed, both via the Grotthuss mechanism and the vehicle or shuttle mechanism (for n = 1 and 2). Thermodynamic considerations allowed a description of the origins of the kinetic trapping effect, which explains the observation of the solution structure in the gas phase. This effect likely occurs in the final evaporation steps, which are outside the droplet size range covered by previous classical molecular dynamics simulations of charged droplets. These results may be considered relevant in determining the nature of the species observed in the ubiquitous ESI based mass spectrometry analysis, and in general for droplet chemistry, explaining how protonation equilibria are drastically changed from bulk to microdroplet conditions.
Collapse
Affiliation(s)
- Patrick R Batista
- Department of Fundamental Chemistry, Institute of Chemistry - University of São Paulo, Av. Prof. Lineu Prestes, 748, Cidade Universitária, São Paulo, SP, Brazil.
| | - Tatiana C Penna
- Department of Fundamental Chemistry, Institute of Chemistry - University of São Paulo, Av. Prof. Lineu Prestes, 748, Cidade Universitária, São Paulo, SP, Brazil.
| | - Lucas C Ducati
- Department of Fundamental Chemistry, Institute of Chemistry - University of São Paulo, Av. Prof. Lineu Prestes, 748, Cidade Universitária, São Paulo, SP, Brazil.
| | - Thiago C Correra
- Department of Fundamental Chemistry, Institute of Chemistry - University of São Paulo, Av. Prof. Lineu Prestes, 748, Cidade Universitária, São Paulo, SP, Brazil.
| |
Collapse
|
42
|
Zhang X, Wang W, Zare RN, Min Q. Peptide and protein assays using customizable bio-affinity arrays combined with ambient ionization mass spectrometry. Chem Sci 2021; 12:10810-10816. [PMID: 34476062 PMCID: PMC8372322 DOI: 10.1039/d1sc02311j] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Accepted: 07/14/2021] [Indexed: 12/25/2022] Open
Abstract
High-throughput identification and quantification of protein/peptide biomarkers from biofluids in a label-free manner is achieved by interfacing bio-affinity arrays (BAAs) with nano-electrospray desorption electrospray ionization mass spectrometry (nano-DESI-MS). A wide spectrum of proteins and peptides ranging from phosphopeptides to cis-diol biomolecules as well as thrombin can be rapidly extracted via arbitrarily predefined affinity interactions including coordination chemistry, covalent bonding, and biological recognition. An integrated MS platform allows continuous interrogation. Profiling and quantitation of dysregulated phosphopeptides from small-volume (∼5 μL) serum samples has been successfully demonstrated. As a front-end device adapted to any mass spectrometer, this MS platform might hold much promise in protein/peptide analysis in point-of-care (POC) diagnostics and clinical applications. Customizable bio-affinity arrays were interfaced with ambient ionization mass spectrometry for high-throughput assays of protein/peptide biomarkers in biofluids.![]()
Collapse
Affiliation(s)
- Xuemeng Zhang
- State Key Laboratory of Analytical Chemistry for Life Science, Chemistry and Biomedicine Innovation Center, School of Chemistry and Chemical Engineering, Nanjing University Nanjing 210023 P. R. China
| | - Wei Wang
- State Key Laboratory of Analytical Chemistry for Life Science, Chemistry and Biomedicine Innovation Center, School of Chemistry and Chemical Engineering, Nanjing University Nanjing 210023 P. R. China
| | - Richard N Zare
- Department of Chemistry, Stanford University Stanford California 94305 USA
| | - Qianhao Min
- State Key Laboratory of Analytical Chemistry for Life Science, Chemistry and Biomedicine Innovation Center, School of Chemistry and Chemical Engineering, Nanjing University Nanjing 210023 P. R. China
| |
Collapse
|
43
|
Plekhova V, Van Meulebroek L, De Graeve M, Perdones-Montero A, De Spiegeleer M, De Paepe E, Van de Walle E, Takats Z, Cameron SJS, Vanhaecke L. Rapid ex vivo molecular fingerprinting of biofluids using laser-assisted rapid evaporative ionization mass spectrometry. Nat Protoc 2021; 16:4327-4354. [PMID: 34341579 DOI: 10.1038/s41596-021-00580-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Accepted: 05/31/2021] [Indexed: 01/29/2023]
Abstract
Of the many metabolites involved in any clinical condition, only a narrow range of biomarkers is currently being used in the clinical setting. A key to personalized medicine would be to extend this range. Metabolic fingerprinting provides a more comprehensive insight, but many methods used for metabolomics analysis are too complex and time-consuming to be diagnostically useful. Here, a rapid evaporative ionization mass spectrometry (REIMS) system for direct ex vivo real-time analysis of biofluids with minor sample pretreatment is detailed. The REIMS can be linked to various laser wavelength systems (such as optical parametric oscillator or CO2 laser) and with automation for high-throughput analysis. Laser-induced sample evaporation occurs within seconds through radiative heating with the plume guided to the MS instrument. The presented procedure includes (i) laser setup with automation, (ii) analysis of biofluids (blood/urine/stool/saliva/sputum/breast milk) and (iii) data analysis. We provide the optimal settings for biofluid analysis and quality control, enabling sensitive, precise and robust analysis. Using the automated setup, 96 samples can be analyzed in ~35-40 min per ionization mode, with no intervention required. Metabolic fingerprints are made up of 2,000-4,000 features, for which relative quantification can be achieved at high repeatability when total ion current normalization is applied. With saliva and feces as example matrices, >70% of features had a coefficient of variance ≤30%. However, to achieve acceptable long-term reproducibility, additional normalizations by, e.g., LOESS are recommended, especially for positive ionization.
Collapse
Affiliation(s)
- Vera Plekhova
- Laboratory of Chemical Analysis, Ghent University, Merelbeke, Belgium
| | - Lieven Van Meulebroek
- Laboratory of Chemical Analysis, Ghent University, Merelbeke, Belgium.,ProDigest BV, Zwijnaarde, Belgium
| | - Marilyn De Graeve
- Laboratory of Chemical Analysis, Ghent University, Merelbeke, Belgium
| | | | | | - Ellen De Paepe
- Laboratory of Chemical Analysis, Ghent University, Merelbeke, Belgium
| | - Emma Van de Walle
- Laboratory of Chemical Analysis, Ghent University, Merelbeke, Belgium
| | - Zoltan Takats
- Department of Surgery and Cancer, Imperial College London, London, UK
| | - Simon J S Cameron
- School of Biological Sciences, Institute for Global Food Security, Queen's University Belfast, Belfast, Northern Ireland, UK
| | - Lynn Vanhaecke
- Laboratory of Chemical Analysis, Ghent University, Merelbeke, Belgium. .,School of Biological Sciences, Institute for Global Food Security, Queen's University Belfast, Belfast, Northern Ireland, UK.
| |
Collapse
|
44
|
Zhang D, Latif M, Gamez G. Instantaneous Differentiation of Functional Isomers via Reactive Flowing Atmospheric Pressure Afterglow Mass Spectrometry. Anal Chem 2021; 93:9986-9994. [PMID: 34251188 DOI: 10.1021/acs.analchem.0c04867] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Ambient mass spectrometry (AMS) allows direct desorption and ionization of analytes in real time with minimal-to-no sample preparation. However, it may present inadequate capabilities for differentiating isomers. Here, a reactive flowing atmospheric-pressure afterglow (reactive-FAPA) AMS source is developed for rapid isomer differentiation by derivatization of analytes in real time. The effects of the reactive-FAPA operating conditions on the reagent and product ions were studied and optimized for highly volatile and non-volatile model compounds with different carbonyl functional groups. In addition, two functional isomers of valproic acid (VPA) metabolites, 4-ene VPA and γ-valprolactone, are successfully differentiated for the first time by incorporating methylamine (MA) reagent vapor into the plasma effluent used for desorption/ionization. Reactive-FAPAMS for 4-ene VPA shows only detectable peaks of the protonated acylation product [M + MA-H2O + H]+, while for γ-valprolactone, it shows detectable peaks for both protonated acylation product [M + MA-H2O + H]+ and protonated intermediate [M + MA + H]+. A method for quantitative characterization of mixtures of 4-ene VPA and γ-valprolactone is also developed and validated. In addition, reactive-FAPAMS also shows better detection sensitivity compared to nonreactive-FAPAMS for some larger analyte types, such as UV filters and steroids. The limit of detection (LOD) of pregnenolone acetate in reactive-FAPAMS is 310 ng/mL, which is about 10 times better than its LOD in nonreactive-FAPA.
Collapse
Affiliation(s)
- Dong Zhang
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - Mohsen Latif
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - Gerardo Gamez
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| |
Collapse
|
45
|
Li C, Li K, Xu X, Qi W, Hu X, Jin P. A pilot study for colorectal carcinoma screening by instant metabolomic profiles using conductive polymer spray ionization mass spectrometry. Biochim Biophys Acta Mol Basis Dis 2021; 1867:166210. [PMID: 34246751 DOI: 10.1016/j.bbadis.2021.166210] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 06/17/2021] [Accepted: 07/06/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND The rapid and accurate discrimination of colorectal carcinoma (CRC) and polyps at the molecular level enables early intervention of CRC, which can greatly improve the 5-year survival rate of patients. Here we reported the potential of conductive polymer spray ionization mass spectrometry (CPSI-MS) in successfully screening CRC according to the serum metabolic profile. METHODS Trace intravenous blood (50 μL) was collected from 60 colorectal carcinoma (CRC) and 60 polyp patients, respectively. After centrifugation, serum (2 μL) was loaded onto the tip of conductive polymer to form a dried serum spot. When the 5 μL methanol-water (1:1, v/v) extraction solvent was spiked onto the dried serum spot followed with +4.5 kV high voltage applied on the polymer tip, the extracted components will be ionized and carried into the MS system for direct metabolic profiling. FINDINGS There were 51 metabolites discovered to be significantly changed in CRC serum compared to polyps. Combining these metabolites as the characteristic panel, the ideal diagnostic performance was achieved by Lasso regression model with the accuracy of 88.3%. INTERPRETATION This pilot study demonstrated the potential of CPSI-MS as a cost-effective tool in large-scale CRC screening in the high-risk population.
Collapse
Affiliation(s)
- Chao Li
- Department of Pharmacy, Beijing Hospital, Beijing 100730, China; National Center of Gerontology, Beijing 100730, China; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing 100730, China; Beijing Key Laboratory of Assessment of Clinical Drugs Risk and Individual Application (Beijing Hospital), Beijing 100730, China
| | - Kexin Li
- National Center of Gerontology, Beijing 100730, China; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing 100730, China; Clinical Trial Center, Beijing Hospital, Beijing 100730, China
| | - Xiaoyu Xu
- National Center of Gerontology, Beijing 100730, China; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing 100730, China; Clinical Trial Center, Beijing Hospital, Beijing 100730, China
| | - Wenyuan Qi
- National Center of Gerontology, Beijing 100730, China; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing 100730, China; Clinical Trial Center, Beijing Hospital, Beijing 100730, China
| | - Xin Hu
- Department of Pharmacy, Beijing Hospital, Beijing 100730, China; National Center of Gerontology, Beijing 100730, China; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing 100730, China; Beijing Key Laboratory of Assessment of Clinical Drugs Risk and Individual Application (Beijing Hospital), Beijing 100730, China
| | - Pengfei Jin
- Department of Pharmacy, Beijing Hospital, Beijing 100730, China; National Center of Gerontology, Beijing 100730, China; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing 100730, China; Beijing Key Laboratory of Assessment of Clinical Drugs Risk and Individual Application (Beijing Hospital), Beijing 100730, China.
| |
Collapse
|
46
|
Abstract
Biomarkers may be diagnostic of asthma, they may predict or reflect response to therapy or they may identify patients at risk of asthma exacerbation. A biomarker is most often measured in biologic fluids that are sampled using relatively non-invasive sampling techniques such as blood, sputum, urine or exhaled breath. Biomarkers should be stable, readily quantifiable and their measurement should be reproducible and not confounded by other host factors, or the presence of comorbidities. However, asthma comprises multiple molecular endotypes and single, sensitive, specific, biomarkers reflecting these endotypes may not exist. Combining biomarkers may improve their predictive capability in asthma. The most well-established endotypes are those described as Type2 and non-Type2 asthma. Clinical trials established the fraction of exhaled nitric oxide (FeNO) and blood eosinophil counts as key biomarkers of response to corticosteroid or targeted anti-inflammatory therapy in Type2 asthma. However, these biomarkers may have limited value in the management of asthma in real-life settings or routine clinical practise. Biomarkers for Type2 asthma are not well described or validated and more research is needed. Breathomics has provided evidence to propose a number of exhaled volatile organic compounds (VOCs) as surrogate biomarkers for airway inflammatory phenotypes, disease activity and adherence to therapy. Analysis of urinary eicosanoids has identified eicosanoids related to Type2 and non-Type2 inflammation. Future clinical trials will be important in determining how exhaled VOCs or urinary eicosanoid profiles can be used to direct precision treatments. Their future clinical use will also depend on developing simplified instrumentation for biomarker analysis at the point-of-care.
Collapse
Affiliation(s)
- Janis Shute
- School of Pharmacy and Biomedical Sciences, Institute of Biomedical and Biomolecular Sciences, University of Portsmouth, Portsmouth, UK -
| |
Collapse
|
47
|
Feider CL, Gatmaitan AN, Hooper T, Chakraborty A, Gowda P, Buchanan E, Eberlin LS. Integrating the MasSpec Pen with Sub-Atmospheric Pressure Chemical Ionization for Rapid Chemical Analysis and Forensic Applications. Anal Chem 2021; 93:7549-7556. [PMID: 34008955 DOI: 10.1021/acs.analchem.1c00393] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Analytical methods that allow rapid, sensitive, and specific chemical measurements are central to forensic analysis and essential to accelerating compound screening and confirmation. We have previously reported the development of the MasSpec Pen technology as an easy-to-use and disposable hand-held device integrated to a mass spectrometer for direct analysis and molecular profiling of biological samples. In this Technical Note, we describe a new apparatus that integrates the MasSpec Pen device with a subatmospheric pressure chemical ionization (sub-APCI) source and an ion trap mass spectrometer for detection and semiquantitative analysis of forensic-related compounds. Coupling the MasSpec Pen device to a sub-APCI source allowed semiquantitative analysis of the drugs cocaine and oxycodone, the agrochemicals atrazine and azoxystrobin, and the explosives trinitrotoluene and dinitroglycerin in under 20 s. Using chemical ionization, improved reproducibility and sensitivity for targeted chemical detection and compound identification was achieved while maintaining the user-friendly features of the hand-held MasSpec Pen device. Limits of detection in the high picogram to low nanogram range were obtained for the compounds analyzed, which are within the range of federal screening cutoffs and those reported for other ambient ionization MS techniques. Altogether, the MasSpec Pen sub-APCI system described enabled rapid and semiquantitative chemical analysis for forensic applications and could be further adapted and applied to other areas of chemical testing.
Collapse
Affiliation(s)
- Clara L Feider
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Abigail N Gatmaitan
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Tim Hooper
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Ashish Chakraborty
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Prajwal Gowda
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Emily Buchanan
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Livia S Eberlin
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
48
|
Eliferov VA, Zhvansky ES, Sorokin AA, Shurkhay VA, Bormotov DS, Pekov SI, Nikitin PV, Ryzhova MV, Kulikov EE, Potapov AA, Nikolaev EN, Popov IA. The Role of Lipids in the Classification of Astrocytoma and Glioblastoma Using Mass Spectrometry Tumor Profiling. BIOCHEMISTRY (MOSCOW), SUPPLEMENT SERIES B: BIOMEDICAL CHEMISTRY 2021. [DOI: 10.1134/s1990750821020025] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
49
|
Zhao J, Yan H, Shi Y, Sheng B, Xiang P. Rapid Characterization of Drugs in Biological Fluid and Seized Material Using Thermal-Assisted Carbon Fiber Ionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:969-976. [PMID: 33779186 DOI: 10.1021/jasms.0c00472] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Developing a rapid, simple, and sensitive method to analyze drugs is critical to forensic research study because of the widespread occurrence of the matrix effect. Herein, we develop a method using thermal-assisted carbon fiber ionization mass spectrometry that can be used to directly analyze drugs in biological fluid. The key feature of this technique is that the biological samples such as urine and blood can be achieved online as precipitated protein on the carbon fiber tip and thermally desorbed by the metal ceramics heater, which can reduce the matrix effects and improve the sensitivity. Analytes including raw urine, blood, oral fluid, drink, tobacco tar, drug tablets, and paper cards can be rapidly identified and analyzed within a few minutes regardless of their physical variations. Due to its simplicity and noninvasive analysis, this method can be used for drugged driving analysis and to achieve point-of-care drug testing in clinical and forensic chemistry.
Collapse
Affiliation(s)
- Junbo Zhao
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - Hui Yan
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - Yan Shi
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - Baohua Sheng
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - Ping Xiang
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| |
Collapse
|
50
|
Zhvansky ES, Eliferov VA, Sorokin AA, Shurkhay VA, Pekov SI, Bormotov DS, Ivanov DG, Zavorotnyuk DS, Bocharov KV, Khaliullin IG, Belenikin MS, Potapov AA, Nikolaev EN, Popov IA. Assessment of variation of inline cartridge extraction mass spectra. JOURNAL OF MASS SPECTROMETRY : JMS 2021; 56:e4640. [PMID: 32798239 DOI: 10.1002/jms.4640] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 07/20/2020] [Accepted: 07/31/2020] [Indexed: 06/11/2023]
Abstract
Recently, mass-spectrometry methods show its utility in tumor boundary location. The effect of differences between research and clinical protocols such as low- and high-resolution measurements and sample storage have to be understood and taken into account to transfer methods from bench to bedside. In this study, we demonstrate a simple way to compare mass spectra obtained by different experimental protocols, assess its quality, and check for the presence of outliers and batch effect in the dataset. We compare the mass spectra of both fresh and frozen-thawed astrocytic brain tumor samples obtained with the inline cartridge extraction prior to electrospray ionization. Our results reveal the importance of both positive and negative ion mode mass spectrometry for getting reliable information about sample diversity. We show that positive mode highlights the difference between protocols of mass spectra measurement, such as fresh and frozen-thawed samples, whereas negative mode better characterizes the histological difference between samples. We also show how the use of similarity spectrum matrix helps to identify the proper choice of the measurement parameters, so data collection would be kept reliable, and analysis would be correct and meaningful.
Collapse
Affiliation(s)
- Evgeny S Zhvansky
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Moscow Region, Russian Federation
| | - Vasiliy A Eliferov
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Moscow Region, Russian Federation
| | - Anatoly A Sorokin
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Moscow Region, Russian Federation
| | - Vsevolod A Shurkhay
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Moscow Region, Russian Federation
- Outpatient department, Federal State Autonomous Institution «N.N. Burdenko National Scientific and Practical Center for Neurosurgery» of the Ministry of Healthcare of the Russian Federation, Moscow, Russian Federation
| | - Stanislav I Pekov
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Moscow Region, Russian Federation
- Center for Computational and Data-Intensive Science and Engineering, Skolkovo Institute of Science and Technology, Moscow, Russian Federation
| | - Denis S Bormotov
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Moscow Region, Russian Federation
| | - Daniil G Ivanov
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Moscow Region, Russian Federation
- Emanuel Institute for Biochemical Physics, Russian Academy of Sciences, Moscow, Russian Federation
| | - Denis S Zavorotnyuk
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Moscow Region, Russian Federation
| | - Konstantin V Bocharov
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Moscow Region, Russian Federation
- V. L. Talrose Institute for Energy Problems of Chemical Physics, N. N. Semenov Federal Center of Chemical Physics, Russian Academy of Sciences, Moscow, Russia
| | - Iliyas G Khaliullin
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Moscow Region, Russian Federation
| | - Maksim S Belenikin
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Moscow Region, Russian Federation
| | - Aleksandr A Potapov
- Outpatient department, Federal State Autonomous Institution «N.N. Burdenko National Scientific and Practical Center for Neurosurgery» of the Ministry of Healthcare of the Russian Federation, Moscow, Russian Federation
| | - Evgeny N Nikolaev
- Center for Computational and Data-Intensive Science and Engineering, Skolkovo Institute of Science and Technology, Moscow, Russian Federation
| | - Igor A Popov
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Moscow Region, Russian Federation
| |
Collapse
|