1
|
Zhang D, Kukkar D, Kim KH, Bhatt P. A comprehensive review on immunogen and immune-response proteins of SARS-CoV-2 and their applications in prevention, diagnosis, and treatment of COVID-19. Int J Biol Macromol 2024; 259:129284. [PMID: 38211928 DOI: 10.1016/j.ijbiomac.2024.129284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 01/03/2024] [Accepted: 01/04/2024] [Indexed: 01/13/2024]
Abstract
Exposure to severe acute respiratory syndrome-corona virus-2 (SARS-CoV-2) prompts humoral immune responses in the human body. As the auxiliary diagnosis of a current infection, the existence of viral proteins can be checked from specific antibodies (Abs) induced by immunogenic viral proteins. For people with a weakened immune system, Ab treatment can help neutralize viral antigens to resist and treat the disease. On the other hand, highly immunogenic viral proteins can serve as effective markers for detecting prior infections. Additionally, the identification of viral particles or the presence of antibodies may help establish an immune defense against the virus. These immunogenic proteins rather than SARS-CoV-2 can be given to uninfected people as a vaccination to improve their coping ability against COVID-19 through the generation of memory plasma cells. In this work, we review immunogenic and immune-response proteins derived from SARS-CoV-2 with regard to their classification, origin, and diverse applications (e.g., prevention (vaccine development), diagnostic testing, and treatment (via neutralizing Abs)). Finally, advanced immunization strategies against COVID-19 are discussed along with the contemporary circumstances and future challenges.
Collapse
Affiliation(s)
- Daohong Zhang
- College of Food Engineering, Ludong University, Yantai 264025, Shandong, China; Bio-Nanotechnology Research Institute, Ludong University, Yantai 264025, Shandong, China
| | - Deepak Kukkar
- Department of Biotechnology, Chandigarh University, Gharuan, Mohali 140413, Punjab, India; University Center for Research and Development, Chandigarh University, Gharuan, Mohali 140413, Punjab, India
| | - Ki-Hyun Kim
- Department of Civil & Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul 04763, Republic of Korea.
| | - Poornima Bhatt
- Department of Biotechnology, Chandigarh University, Gharuan, Mohali 140413, Punjab, India; University Center for Research and Development, Chandigarh University, Gharuan, Mohali 140413, Punjab, India
| |
Collapse
|
2
|
Zhang W, Xu X, Qi L, Liu M, Zhao X, Kong L, Wang Y, Chen F, Zhang C, Cheng J, Zheng W. Clinical evaluation of a new COVID-19 antigen rapid test kit for detection of SARS-CoV-2. Diagn Microbiol Infect Dis 2024; 108:116136. [PMID: 38041889 DOI: 10.1016/j.diagmicrobio.2023.116136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 11/10/2023] [Accepted: 11/14/2023] [Indexed: 12/04/2023]
Abstract
The antigen rapid diagnostic test (Ag-RDT) is an assay kit for detecting the SARS-COV-2 nucleocapsid proteins, based on the colloidal gold method.Accurate diagnosis has an important role in limiting the transmission of SARS-COV-2, and also helps patients to receive earlier treatment .The object of this study was to perform the clinical evaluation of a novel Ag-RDTs with samples collected from two different swabs.DEEPBLUE®COVID-19 antigen detection kit used for the examination of the subjects in the experiment.For antigen testing on samples collected with nasal swabs, sensitivity was 91.7 % (95 % CI 83.6-96.6 %) and specificity was 100 %(95 %CI 98.1-100 %).For nasopharyngeal swabs, the sensitivity was 96.8 % (95 % CI 93.6-98.7 %) and the specificity was 100 % (95 % CI 98.2-100 %).Fisher Precision test showed a significant correlation between nasopharyngeal swab Ag-RDTs and nasal swab Ag-RDTs and RT-qPCR test (p-value <0.001).The results showed that the patients use the kit for testing were comparable to the RT-qPCR.
Collapse
Affiliation(s)
- Wenjing Zhang
- Department of Laboratory Medicine, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230001, Anhui, China
| | - Xiaoliang Xu
- School of Laboratory Medicine, Bengbu Medical College, Bengbu 233030, Anhui, China
| | - Liangshuai Qi
- School of Laboratory Medicine, Bengbu Medical College, Bengbu 233030, Anhui, China
| | - Mingkai Liu
- Department of Laboratory Medicine, The First Affiliated Hospital, Shihezi University, Shihezi 832008, Xinjiang, China
| | - Xiaoying Zhao
- Department of Laboratory Medicine, The First Affiliated Hospital, Shihezi University, Shihezi 832008, Xinjiang, China
| | - Lingshang Kong
- Department of General Surgery, The Second Affiliated Hospital of Anhui Medical University, Hefei 230601, Anhui, China
| | - Yingji Wang
- Department of Geriatric Endocrinology, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, 610072, Sichuan, China
| | - Fengling Chen
- Anhui DeepBlue Medical Technology Co. Ltd., Hefei, 230088, Anhui, China
| | - Chao Zhang
- Anhui DeepBlue Medical Technology Co. Ltd., Hefei, 230088, Anhui, China.
| | - Jianghua Cheng
- Institute of Agricultural Products Processing, Anhui Academy of Agricultural Sciences, Hefei 230031, Anhui, China.
| | - Weiwei Zheng
- Department of Laboratory Medicine, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230001, Anhui, China.
| |
Collapse
|
3
|
Bottino P, Pizzo V, Castaldo S, Scomparin E, Bara C, Cerrato M, Sisinni S, Penpa S, Roveta A, Gerbino M, Maconi A, Rocchetti A. Clinical Evaluation and Comparison of Two Microfluidic Antigenic Assays for Detection of SARS-CoV-2 Virus. Microorganisms 2023; 11:2709. [PMID: 38004721 PMCID: PMC10673207 DOI: 10.3390/microorganisms11112709] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 10/27/2023] [Accepted: 11/03/2023] [Indexed: 11/26/2023] Open
Abstract
Given the ongoing pandemic, there is a need to identify SARS-CoV-2 and differentiate it from other respiratory viral infections in various critical settings. Since its introduction, rapid antigen testing is spreading worldwide, but diagnostic accuracy is extremely variable and often in disagreement with the manufacturer's specifications. Our study compared the clinical performances of two microfluidic rapid antigen tests towards a molecular assay, starting from positive samples. A total of 151 swabs collected at the Microbiology and Virology Laboratory of A.O. "SS Antonio e Biagio e C. Arrigo" (Alessandria, Italy) for the diagnosis of SARS-CoV-2 were simultaneously tested to evaluate accuracy, specificity, and agreement with the RT-qPCR results. Both assays showed an overall agreement of 100% for negative specimens, while positive accuracy comprised between 45.10% and 54.90%. According to the manufacturer's instructions, the greatest correlation between the antigenic and molecular assays was observed for the subset with high viral load (18/19, 94.74%), while it dramatically decreased for other subsets. Moreover, the ability to differentiate between SARS-CoV-2 and Flu provides an added value and could be addressed in an epidemic context. However, an in-house validation should be performed due to differences observed in performance declared by manufacturers and those actually obtained.
Collapse
Affiliation(s)
- Paolo Bottino
- Microbiology and Virology Laboratory, A.O. “SS Antonio e Biagio e C. Arrigo”, Via Venezia 16, 15121 Alessandria, Italy; (V.P.); (S.C.); (E.S.); (C.B.); (M.C.); (A.R.)
| | - Valentina Pizzo
- Microbiology and Virology Laboratory, A.O. “SS Antonio e Biagio e C. Arrigo”, Via Venezia 16, 15121 Alessandria, Italy; (V.P.); (S.C.); (E.S.); (C.B.); (M.C.); (A.R.)
| | - Salvatore Castaldo
- Microbiology and Virology Laboratory, A.O. “SS Antonio e Biagio e C. Arrigo”, Via Venezia 16, 15121 Alessandria, Italy; (V.P.); (S.C.); (E.S.); (C.B.); (M.C.); (A.R.)
| | - Elisabetta Scomparin
- Microbiology and Virology Laboratory, A.O. “SS Antonio e Biagio e C. Arrigo”, Via Venezia 16, 15121 Alessandria, Italy; (V.P.); (S.C.); (E.S.); (C.B.); (M.C.); (A.R.)
| | - Cristina Bara
- Microbiology and Virology Laboratory, A.O. “SS Antonio e Biagio e C. Arrigo”, Via Venezia 16, 15121 Alessandria, Italy; (V.P.); (S.C.); (E.S.); (C.B.); (M.C.); (A.R.)
| | - Marcella Cerrato
- Microbiology and Virology Laboratory, A.O. “SS Antonio e Biagio e C. Arrigo”, Via Venezia 16, 15121 Alessandria, Italy; (V.P.); (S.C.); (E.S.); (C.B.); (M.C.); (A.R.)
| | - Sabrina Sisinni
- Research and Innovation Department (DAIRI), A.O. “SS. Antonio e Biagio e C. Arrigo”, Via Venezia 16, 15121 Alessandria, Italy; (S.S.); (S.P.); (A.R.); (A.M.)
| | - Serena Penpa
- Research and Innovation Department (DAIRI), A.O. “SS. Antonio e Biagio e C. Arrigo”, Via Venezia 16, 15121 Alessandria, Italy; (S.S.); (S.P.); (A.R.); (A.M.)
| | - Annalisa Roveta
- Research and Innovation Department (DAIRI), A.O. “SS. Antonio e Biagio e C. Arrigo”, Via Venezia 16, 15121 Alessandria, Italy; (S.S.); (S.P.); (A.R.); (A.M.)
| | - Maria Gerbino
- Department of Science and Technological Innovation (DISIT), University of Eastern Piedmont, Viale Teresa Michel 11, 15121 Alessandria, Italy;
| | - Antonio Maconi
- Research and Innovation Department (DAIRI), A.O. “SS. Antonio e Biagio e C. Arrigo”, Via Venezia 16, 15121 Alessandria, Italy; (S.S.); (S.P.); (A.R.); (A.M.)
| | - Andrea Rocchetti
- Microbiology and Virology Laboratory, A.O. “SS Antonio e Biagio e C. Arrigo”, Via Venezia 16, 15121 Alessandria, Italy; (V.P.); (S.C.); (E.S.); (C.B.); (M.C.); (A.R.)
| |
Collapse
|
4
|
de Almeida MT, Barbosa AP, Bomfim CG, Visnardi AB, Vinces TC, Ceroni A, Durigon EL, Guzzo CR. Obtaining a high titer of polyclonal antibodies from rats to the SARS-CoV-2 nucleocapsid protein and its N- and C-terminal domains for diagnostic test development. J Immunol Methods 2023; 522:113558. [PMID: 37704125 DOI: 10.1016/j.jim.2023.113558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 08/30/2023] [Accepted: 09/05/2023] [Indexed: 09/15/2023]
Abstract
Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is an enveloped, plus-stranded RNA virus responsible for the Coronavirus Disease 2019 (COVID-19). Patients infected with COVID-19 may be asymptomatic or have symptoms ranging from mild manifestations to severe cases of the disease that could lead to death. The SARS-CoV-2 genome encodes 4 structural proteins, including the Spike protein (S), the Nucleocapsid protein (N), Membrane protein (M) and, the Envelope protein (E). The N protein forms a major component of the ribonucleoprotein complex within the virus particle and play a vital role in its transcription and replication. Nevertheless, the S protein was the most important protein in the development of vaccines against COVID-19. However, the decrease in number of registered immunizations against the disease and the rapid drop in neutralizing antibody titers together with looser preventive measures for virus transmission, favored the rapid appearance of new variants of concerns (VOCs) that primarily show mutations in the S protein. This fact makes the N protein a good candidate for the development of diagnostic tests, due to its stability, amino acid conservation, high immunogenicity, and the smaller likelihood of mutation. With the aim of developing a new diagnostic kit based on the N protein, we evaluated the humoral response in female Wistar rats against this target. Three constructions of the N protein were used to inoculate the animals: the full-length protein (Cfull), the N- (NTD), and the C-terminal (CTD) portion of the protein. The immunizations induced the animal's immune response, with specific polyclonal IgG antibodies against the Cfull protein and its fragments. There were not non-specific bind to the protein used as negative control. Anti-Cfull antibodies demonstrated high efficiency in binding to the NTD protein and the antibodies present in the anti-CTD and anti-NTD sera have recognized the Cfull protein, but they were not able to recognize the NTD and CTD proteins, respectively. Our results indicate an efficient protocol for obtaining high antibody titers against the N recombinant protein of SARS-CoV-2 and its fragments highlighting the Cfull protein, which can be used in the development of new diagnostic kits.
Collapse
Affiliation(s)
| | - Ana Paula Barbosa
- Department of Microbiology, Institute of Biomedical Sciences, University of São Paulo, São Paulo, Brazil
| | - Camila Gasque Bomfim
- Department of Microbiology, Institute of Biomedical Sciences, University of São Paulo, São Paulo, Brazil
| | - Aline Biazola Visnardi
- Department of Microbiology, Institute of Biomedical Sciences, University of São Paulo, São Paulo, Brazil
| | - Tania Churasacari Vinces
- Department of Microbiology, Institute of Biomedical Sciences, University of São Paulo, São Paulo, Brazil
| | - Alexandre Ceroni
- Department of Physiology and Biophysics, Institute of Biomedical Sciences, University of São Paulo, São Paulo, Brazil
| | - Edison Luiz Durigon
- Department of Microbiology, Institute of Biomedical Sciences, University of São Paulo, São Paulo, Brazil; Scientific Platform Pasteur USP, São Paulo, Brazil
| | - Cristiane Rodrigues Guzzo
- Department of Microbiology, Institute of Biomedical Sciences, University of São Paulo, São Paulo, Brazil.
| |
Collapse
|
5
|
Bernasconi L, Neyer P, Oberle M, Schmid B, Martin E, Fankhauser H, Haubitz S, Hammerer-Lercher A. Efficiency evaluation of a SARS-CoV-2 diagnostic strategy combining high throughput quantitative antigen immunoassay and real time PCR. Clin Chem Lab Med 2023; 61:1661-1669. [PMID: 36947812 DOI: 10.1515/cclm-2023-0087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Accepted: 03/08/2023] [Indexed: 03/24/2023]
Abstract
OBJECTIVES Laboratory testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has played an important role in the effort to prevent and contain local outbreaks. The aim of this study was to assess the diagnostic accuracy of a new fully automated SARS-CoV-2 laboratory-based antigen assay (CoV2Ag) and to explore the efficiency of a diagnostic algorithm combining antigen and conventional high-throughput molecular assays to address potential future challenges of the SARS-CoV-2 pandemic. METHODS One thousand two hundred and twenty four consecutive nasopharyngeal swabs were tested using RT-PCR and CoV2Ag assay. RESULTS The overall sensitivity and specificity of CoV2Ag were 79.1 and 97.8%, respectively. When the analysis was restricted to cases with Ct values ≤30, the sensitivity of the assay improved to 98.1%. Acceptable sensitivity was found when the analysis was limited to patients presenting within one or two to four days of symptom onset (80.5 and 84.8%, respectively). A retrospective analysis of the use of a two-step diagnostic approach combining the CoV2Ag assay and RT-PCR during an acute pandemic phase of 97 days showed a potential reduction in the number of RT-PCR tests by 36.1%, corresponding to savings in reagent costs and technician workload of approximately €8,000 and 10.5 h per day, respectively. CONCLUSIONS Our data show that the proposed algorithm represents a valid alternative diagnostic approach to increase testing efficiency during future pandemic phases with high positivity rates (>20%) and elevated numbers of RT-PCR test requests.
Collapse
Affiliation(s)
- Luca Bernasconi
- Institute of Laboratory Medicine, Kantonsspital Aarau AG, Aarau, Switzerland
| | - Peter Neyer
- Institute of Laboratory Medicine, Kantonsspital Aarau AG, Aarau, Switzerland
| | - Michael Oberle
- Institute of Laboratory Medicine, Kantonsspital Aarau AG, Aarau, Switzerland
| | - Bettina Schmid
- Institute of Laboratory Medicine, Kantonsspital Aarau AG, Aarau, Switzerland
| | - Eileen Martin
- Department of Infectious Diseases and Hospital Hygiene, Kantonsspital Aarau AG, Aarau, Switzerland
| | - Hans Fankhauser
- Institute of Laboratory Medicine, Kantonsspital Aarau AG, Aarau, Switzerland
| | - Sebastian Haubitz
- Department of Infectious Diseases and Hospital Hygiene, Kantonsspital Aarau AG, Aarau, Switzerland
| | | |
Collapse
|
6
|
Vierbaum L, Wojtalewicz N, Grunert HP, Zimmermann A, Scholz A, Goseberg S, Kaiser P, Duehring U, Drosten C, Corman V, Niemeyer D, Rabenau HF, Obermeier M, Nitsche A, Michel J, Puyskens A, Huggett JF, O'Sullivan DM, Busby E, Cowen S, Vallone PM, Cleveland MH, Falak S, Kummrow A, Schellenberg I, Zeichhardt H, Kammel M. Results of German external quality assessment schemes for SARS-CoV-2 antigen detection. Sci Rep 2023; 13:13206. [PMID: 37580353 PMCID: PMC10425338 DOI: 10.1038/s41598-023-40330-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 08/08/2023] [Indexed: 08/16/2023] Open
Abstract
The COVID-19 pandemic illustrated the important role of diagnostic tests, including lateral flow tests (LFTs), in identifying patients and their contacts to slow the spread of infections. INSTAND performed external quality assessments (EQA) for SARS-CoV-2 antigen detection with lyophilized and chemically inactivated cell culture supernatant of SARS-CoV-2 infected Vero cells. A pre-study demonstrated the suitability of the material. Participants reported qualitative and/or quantitative antigen results using either LFTs or automated immunoassays for five EQA samples per survey. 711 data sets were reported for LFT detection in three surveys in 2021. This evaluation focused on the analytical sensitivity of different LFTs and automated immunoassays. The inter-laboratory results showed at least 94% correct results for non-variant of concern (VOC) SARS-CoV-2 antigen detection for viral loads of ≥ 4.75 × 106 copies/mL and SARS-CoV-2 negative samples. Up to 85% had success for a non-VOC viral load of ~ 1.60 × 106 copies/mL. A viral load of ~ 1.42 × 107 copies/mL of the Delta VOC was reported positive in > 96% of results. A high specificity was found with almost 100% negative SARS-CoV-2 antigen results for HCoV 229E and HCoV NL63 positive samples. Quantitative results correlated with increasing SARS-CoV-2 viral load but showed a broad scatter. This study shows promising SARS-CoV-2 antigen test performance of the participating laboratories, but further investigations with the now predominant Omicron VOC are needed.
Collapse
Affiliation(s)
- Laura Vierbaum
- INSTAND E.V., Society for Promoting Quality Assurance in Medical Laboratories, Ubierstr. 20, 40223, Düsseldorf, Germany.
| | - Nathalie Wojtalewicz
- INSTAND E.V., Society for Promoting Quality Assurance in Medical Laboratories, Ubierstr. 20, 40223, Düsseldorf, Germany
| | - Hans-Peter Grunert
- GBD Gesellschaft für Biotechnologische Diagnostik mbH, Berlin, Potsdamer Chaussee 80, 14129, Berlin, Germany
| | - Anika Zimmermann
- IQVD GmbH, Institut für Qualitätssicherung in der Virusdiagnostik, Berlin, Potsdamer Chaussee 80, 14129, Berlin, Germany
| | - Annemarie Scholz
- IQVD GmbH, Institut für Qualitätssicherung in der Virusdiagnostik, Berlin, Potsdamer Chaussee 80, 14129, Berlin, Germany
| | - Sabine Goseberg
- INSTAND E.V., Society for Promoting Quality Assurance in Medical Laboratories, Ubierstr. 20, 40223, Düsseldorf, Germany
| | - Patricia Kaiser
- INSTAND E.V., Society for Promoting Quality Assurance in Medical Laboratories, Ubierstr. 20, 40223, Düsseldorf, Germany
| | - Ulf Duehring
- GBD Gesellschaft für Biotechnologische Diagnostik mbH, Berlin, Potsdamer Chaussee 80, 14129, Berlin, Germany
| | - Christian Drosten
- Institute of Virology, Charité - University Medicine Berlin; National Consultant Laboratory for Coronaviruses; German Centre for Infection Research, Berlin, Berlin, Germany
| | - Victor Corman
- Institute of Virology, Charité - University Medicine Berlin; National Consultant Laboratory for Coronaviruses; German Centre for Infection Research, Berlin, Berlin, Germany
| | - Daniela Niemeyer
- Institute of Virology, Charité - University Medicine Berlin; National Consultant Laboratory for Coronaviruses; German Centre for Infection Research, Berlin, Berlin, Germany
| | - Holger F Rabenau
- Institute of Virology, Charité - University Medicine Berlin; National Consultant Laboratory for Coronaviruses; German Centre for Infection Research, Berlin, Berlin, Germany
| | - Martin Obermeier
- Institute for Medical Virology, University Hospital, Goethe University Frankfurt, Frankfurt, Hessen, Germany
| | | | - Janine Michel
- Robert Koch Institute, Highly Pathogenic Viruses, Centre for Biological Threats and Special Pathogens, WHO Reference Laboratory for SARS-CoV-2 and WHO Collaborating Centre for Emerging Infections and Biological Threats, Robert Koch Institute, Berlin, Germany
| | - Andreas Puyskens
- Robert Koch Institute, Highly Pathogenic Viruses, Centre for Biological Threats and Special Pathogens, WHO Reference Laboratory for SARS-CoV-2 and WHO Collaborating Centre for Emerging Infections and Biological Threats, Robert Koch Institute, Berlin, Germany
| | - Jim F Huggett
- National Measurement Laboratory, LGC, Teddington, Middlesex, UK
- School of Biosciences and Medicine, Faculty of Health and Medical Science, University of Surrey, Guildford, UK
| | | | - Eloise Busby
- National Measurement Laboratory, LGC, Teddington, Middlesex, UK
| | - Simon Cowen
- National Measurement Laboratory, LGC, Teddington, Middlesex, UK
| | - Peter M Vallone
- NIST, National Institute of Standards and Technology, Applied Genetics Group, Biomolecular Measurement Division, Materials Measurement Laboratory, Gaithersburg, MD, USA
| | - Megan H Cleveland
- NIST, National Institute of Standards and Technology, Applied Genetics Group, Biomolecular Measurement Division, Materials Measurement Laboratory, Gaithersburg, MD, USA
| | - Samreen Falak
- Physikalisch-Technische Bundesanstalt, Berlin, Germany
| | | | - Ingo Schellenberg
- INSTAND E.V., Society for Promoting Quality Assurance in Medical Laboratories, Ubierstr. 20, 40223, Düsseldorf, Germany
- Institute of Bioanalytical Sciences, Center of Life Sciences, Anhalt University of Applied Sciences, Bernburg, Saxony-Anhalt, Germany
| | - Heinz Zeichhardt
- INSTAND E.V., Society for Promoting Quality Assurance in Medical Laboratories, Ubierstr. 20, 40223, Düsseldorf, Germany
- IQVD GmbH, Institut für Qualitätssicherung in der Virusdiagnostik, Berlin, Potsdamer Chaussee 80, 14129, Berlin, Germany
- GBD Gesellschaft für Biotechnologische Diagnostik mbH, Berlin, Potsdamer Chaussee 80, 14129, Berlin, Germany
| | - Martin Kammel
- INSTAND E.V., Society for Promoting Quality Assurance in Medical Laboratories, Ubierstr. 20, 40223, Düsseldorf, Germany
- IQVD GmbH, Institut für Qualitätssicherung in der Virusdiagnostik, Berlin, Potsdamer Chaussee 80, 14129, Berlin, Germany
| |
Collapse
|
7
|
Lippi G, Henry BM, Plebani M. Diagnostic accuracy of Siemens SARS-CoV-2 Antigen (CoV2Ag) chemiluminescent immunoassay for diagnosing acute SARS-CoV-2 infection: a pooled analysis. Clin Chem Lab Med 2023; 61:1133-1139. [PMID: 36634305 DOI: 10.1515/cclm-2022-1287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 01/03/2023] [Indexed: 01/13/2023]
Abstract
BACKGROUND This article provides a critical literature review and pooled analysis of diagnostic accuracy of the fully-automated Siemens SARS-CoV-2 Antigen (CoV2Ag) chemiluminescent immunoassay for diagnosis of acute SARS-CoV-2 infections. METHODS An electronic search was conducted in Scopus, PubMed and medRxiv using the keywords ["Siemens AND CoV2Ag"] OR ["Siemens AND SARS-CoV-2 AND antigen"] for capturing studies that investigated the accuracy of Siemens CoV2Ag for diagnosing acute SARS-CoV-2 infection against a reference SARS-CoV-2 molecular test. The retrieved information was used for constructing a 2 × 2 table and for calculating pooled diagnostic sensitivity, specificity, Summary Receiver Operating Characteristic Curve (SROC) and Agreement. This study followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) reporting checklist. RESULTS Four studies totalling 1,310 respiratory samples (612 with high viral load) were finally included in our analysis. The cumulative area under the curve, accuracy, sensitivity, specificity, were 0.964 (95% CI, 0.957-0.971), 86.9% (95% CI, 84.9-88.7%), 0.79 (95% CI, 0.76-0.82) and 0.98 (95% CI, 0.96-0.99), respectively. The negative (NPV) and positive (PPV) predictive values were 0.77 (0.74-0.79) and 0.98 (95% CI, 0.96-99), respectively. The diagnostic sensitivity in samples with high viral load (i.e., Ct<29-30) was 0.95 (95% CI, 0.93-0.97). CONCLUSIONS The Siemens CoV2Ag fully-automated and high-throughput immunoassay approximates the minimum performance criteria for general SARS-CoV-2 antigen testing and displays excellent performance in samples with high viral load, thus representing a valuable screening solution for risk assessment in COVID-19 and for limiting viral spread.
Collapse
Affiliation(s)
- Giuseppe Lippi
- IFCC Task Force on COVID-19, Milano, Italy
- IFCC WG on SARS-CoV-2 variants, Milano, Italy
- Section of Clinical Biochemistry and School of Medicine, University of Verona, Verona, Italy
| | - Brandon M Henry
- IFCC Task Force on COVID-19, Milano, Italy
- IFCC WG on SARS-CoV-2 variants, Milano, Italy
- Clinical Laboratory, Division of Nephrology and Hypertension, Cincinnati Children's Hospital Medical Center, Cincinnati OH, USA
| | - Mario Plebani
- IFCC Task Force on COVID-19, Milano, Italy
- IFCC WG on SARS-CoV-2 variants, Milano, Italy
- Department of Medicine, University of Padova, Padova, Italy
| |
Collapse
|
8
|
Olver P, Bohn MK, Adeli K. Central role of laboratory medicine in public health and patient care. Clin Chem Lab Med 2023; 61:666-673. [PMID: 36436024 DOI: 10.1515/cclm-2022-1075] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Accepted: 11/18/2022] [Indexed: 11/28/2022]
Abstract
Clinical laboratories play a vital role in the healthcare system. Objective medical data provided by clinical laboratories supports approximately 60-70% of clinical decisions, however, evidence supporting this claim is poorly documented and laboratories still lack visibility, despite their indisputable impact on patient care and public health. The International Federation for Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Outcome Studies in Laboratory Medicine (TF-OSLM) was recently developed to support directed research evaluating the role of laboratory medicine on clinical outcomes. Establishing and documenting this evidence is key to enhance visibility of the field in the eye of the public and other healthcare professionals together with optimizing patient outcomes and health care system operations. In this review, we discuss four areas that exemplify the contribution of laboratory medicine directly to patient care. This includes high-sensitivity cardiac troponin (hs-cTn) and N-terminal pro-B-type natriuretic peptide/B-type natriuretic peptides (NT-proBNP/BNP) for the diagnosis and prognosis of myocardial infarction and heart failure, respectively, and procalcitonin for the management of sepsis and antibiotic stewardship. Emerging markers of traumatic brain injury and the role of laboratory medicine in the fight against the COVID-19 pandemic are discussed along with an introduction to plans of IFCC TF-OSLM.
Collapse
Affiliation(s)
- Pyper Olver
- CALIPER Program, Department of Paediatric Laboratory Medicine, The Hospital for Sick Children, Toronto, ON, Canada
| | - Mary Kathryn Bohn
- CALIPER Program, Department of Paediatric Laboratory Medicine, The Hospital for Sick Children, Toronto, ON, Canada.,Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada
| | - Khosrow Adeli
- CALIPER Program, Department of Paediatric Laboratory Medicine, The Hospital for Sick Children, Toronto, ON, Canada.,Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
9
|
Salvagno GL, Henry BM, Bongiovanni G, De Nitto S, Pighi L, Lippi G. Positivization time of a COVID-19 rapid antigen self-test predicts SARS-CoV-2 viral load: a proof of concept. Clin Chem Lab Med 2023; 61:316-322. [PMID: 36315978 DOI: 10.1515/cclm-2022-0873] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 10/16/2022] [Indexed: 11/09/2022]
Abstract
OBJECTIVES This proof of concept study was aimed to validate the hypothesis that the time of positivization of SARS-CoV-2 self-performed rapid diagnostic tests (RDTs) may reflect the actual viral load in the specimen. METHODS A SARS-CoV-2 positive sample with high viral load was diluted and concomitantly assayed with molecular assay (Xpert Xpress SARS-CoV-2) and RDT (COVID-VIRO ALL IN RDT). The (mean cycle threshold; Ct) values and RDT positivization times of these dilutions were plotted and interpolated by calculating the best fit. The parameters of this equation were then used for converting the positivization times into RDT-estimated SARS-CoV-2 Ct values in routine patient samples. RESULTS The best fit between measured and RDT-estimated Ct values could be achieved with a 2-degree polynomial curve. The RDT-estimated Ct values exhibited high correlation (r=0.996) and excellent Deming fit (y=1.01 × x - 0.18) with measured Ct values. In 30 consecutive patients with positive RDT test, the correlation between RDT positivization time and measured Ct value was r=0.522 (p=0.003). The correlation of RDT-estimated and measured Ct values slightly improved to 0.577 (Deming fit: y=0.44 × x + 11.08), displaying a negligible bias (1.0; 95% CI, -0.2 to 2.2; p=0.105). Concordance of RDT-estimated and measured Ct values at the <20 cut-off was 80%, with 0.84 sensitivity and 0.73 specificity. CONCLUSIONS This proof of concept study demonstrates the potential feasibility of using RDTs for garnering information on viral load in patients with acute SARS-CoV-2 infection.
Collapse
Affiliation(s)
- Gian Luca Salvagno
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
- Service of Laboratory Medicine, Pederzoli Hospital, Peschiera del Garda, Italy
| | - Brandon M Henry
- Clinical Laboratory, Division of Nephrology and Hypertension, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | | | - Simone De Nitto
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
- Service of Laboratory Medicine, Pederzoli Hospital, Peschiera del Garda, Italy
| | - Laura Pighi
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
- Service of Laboratory Medicine, Pederzoli Hospital, Peschiera del Garda, Italy
| | - Giuseppe Lippi
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| |
Collapse
|
10
|
Favresse J, Douxfils J, Henry B, Lippi G, Plebani M. Clinical Chemistry and Laboratory Medicine celebrates 60 years – narrative review devoted to the contribution of the journal to the diagnosis of SARS-CoV-2. Clin Chem Lab Med 2022; 61:811-821. [PMID: 36420539 DOI: 10.1515/cclm-2022-1166] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Accepted: 11/16/2022] [Indexed: 11/25/2022]
Abstract
Abstract
This review is an integral part of the special issue for the 60 years of the journal Clinical Chemistry and Laboratory Medicine (CCLM). The aim of the review is to highlight the role of the clinical laboratory since the emergence of the “severe acute respiratory syndrome coronavirus 2” (SARS-CoV-2), which causes Coronavirus disease 2019 (COVID-19), with special focus on the contribution of the journal in generating knowledge in SARS-CoV-2 diagnosis. As of October 30, 2022, a total of 186 CCLM publications were dedicated to COVID-19. Of importance, major International Federation of Clinical Chemistry (IFCC) guidelines related to the diagnosis of COVID-19 were published in CCLM. Between early-2020 and late October 2022, COVID-19 publications represented around 27% of all articles in CCLM, highlighting the willingness of the editorial board to help the field in order to better describe and diagnose this new emerging disease. First launched in 1963 under the name “Zeitschrift für Klinische Chemie”, the Journal was entirely devoted to clinical chemistry in the strict sense. The various topics published in relation to COVID-19 including its diagnosis, its impact on biochemical or hematological measures, as well as biosafety measures, is the perfect example that shows that the journal has greatly diversified over time.
Collapse
Affiliation(s)
- Julien Favresse
- IFCC SARS-CoV-2 Variants Working Group , Verona , Italy
- Department of Laboratory Medicine , Clinique St-Luc Bouge , Namur , Belgium
- Department of Pharmacy , Namur Research Institute for Lifes Sciences, University of Namur , Namur , Belgium
| | - Jonathan Douxfils
- Department of Pharmacy , Namur Research Institute for Lifes Sciences, University of Namur , Namur , Belgium
- Qualiblood s.a. , Namur , Belgium
| | - Brandon Henry
- IFCC SARS-CoV-2 Variants Working Group , Verona , Italy
- Clinical Laboratory, Division of Nephrology and Hypertension, Cincinnati Children’s Hospital Medical Center , Cincinnati , OH , USA
| | - Giuseppe Lippi
- IFCC SARS-CoV-2 Variants Working Group , Verona , Italy
- Section of Clinical Biochemistry and School of Medicine, University of Verona , Verona , Italy
| | - Mario Plebani
- IFCC SARS-CoV-2 Variants Working Group , Verona , Italy
- Department of Laboratory Medicine , University-Hospital of Padova , Padova , Italy
| |
Collapse
|
11
|
Carta M, Pascarella M, Cappelletti A, Rassu M, Giavarina D. Evaluating the role of a fully automated SARS-CoV-2 antigen ECLIA immunoassay in the management of the SARS COV 2 pandemic on general population. Diagnosis (Berl) 2022; 9:491-498. [PMID: 36181728 DOI: 10.1515/dx-2022-0067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Accepted: 09/15/2022] [Indexed: 12/29/2022]
Abstract
OBJECTIVES Chemiluminescence immunoassay (CLIA) automated assays (fourth-generation antigen test) for SARS-CoV-2 detection are promising because of their analytical productivity, but have lower sensitivity and specificity than rt-PCR assays. The authors of this paper evaluated a recent immunoassay implemented on Siemens Atellica IM, investigating how much this could affect the actual feasibility of this diagnostic during the pandemic. METHODS From the three-day routine 134 positive and 241 negative swab samples by rt-PCR test were evaluated, selected as 1/3 positive - 2/3 negative. RESULTS Using rt-PCR as gold standard, the specificity of immunoassay was 96.7%, while sensitivity was 68.0%. Sensitivity is inversely proportional to the viral load: 100% for cycles threshold (CT) values from 14 to 29, 95% until 30 CT, then 85, 74, 72, 68%, for 31-35 CT respectively. CONCLUSIONS Our study confirms the reliability of the fourth-generation antigen assay in recognizing negative samples. Conversely, sensitivity appears to be less reliable (68.0%) than reported in the literature. This could be due to a non-randomized study group: many swab samples were taken from patients with expected low viral load (hospitalized for COVID for more than 10-12 days or asymptomatic patients for epidemiological surveillance). The strong correlation of sensitivity and viral load could prove significant to track the infectiousness of infected people, as previous studies reported that a viral load of at least 10E6 copies of RNA/mL, corresponding to 25 CT, is the threshold of transmission of the disease.
Collapse
Affiliation(s)
| | | | | | - Mario Rassu
- Microbiology Unit, AULSS 8 Berica, Vicenza, Italy
| | | |
Collapse
|
12
|
Salvagno GL, Henry BM, de NS, Pighi L, Lippi G. Association between viral load and positivization time of a SARS-CoV-2 rapid antigen test in routine nasopharyngeal specimens. J Med Biochem 2022; 41:513-517. [PMID: 36381068 PMCID: PMC9618342 DOI: 10.5937/jomb0-35482] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 01/25/2022] [Indexed: 10/29/2023] Open
Abstract
BACKGROUND Rapid SARS-CoV-2 antigen tests are potentially useful tools for screening carriers with high viral load. This study was aimed to assess the potential association between viral load and positivization time of a manual SARS-CoV-2 commercial antigen test in routine nasopharyngeal specimens. METHODS In a sample of subjects undergoing routine diagnostic testing, SARS-CoV-2 positivity of nasopharyngeal samples was assayed with both molecular (Altona Diagnostics RealStar SARS-CoV-2 RT-PCR Kit) and antigenic (Roche SARS-CoV-2 Rapid Antigen Test) tests. Positivization time of rapid antigen test was correlated and compared with viral load expressed as mean of SARS-CoV2 E/S genes cycle threshold (Ct) values. RESULTS The study sample consisted of 106 patients (median age 48 years, 55 women) with positive results of rapid SARS-CoV-2 antigen testing. A highly significant Spearman's correlation was found between mean SARSCoV-2 E/S genes Ct values and positivization time of manual antigen test (r= 0.70; p<0.001). The positivization time of rapid SARS-CoV-2 antigen test displayed an area under the curve of 0.82 (95%CI, 0.74-0.89) for predicting nasopharyngeal samples with high viral load (i.e., mean Ct <20). A positivization time cut-off of 32 SEC had 94.9% sensitivity and 58.2% specificity for detecting specimens with high viral load. The overall agreement between mean Ct value <20 and positivization time <32 SEC was 70.8%. CONCLUSIONS Positivization time of rapid SARS-CoV-2 antigen tests may provide easy and rapid information on viral load, thus making this type of manual assay potentially suitable for quick and reliable detection and isolation of supercarriers.
Collapse
Affiliation(s)
| | - Brandon M. Henry
- Cincinnati Children's Hospital Medical Center, Division of Nephrology and Hypertension, Clinical Laboratory, Cincinnati, United States of America
| | - Nitto Simone de
- University of Verona, Section of Clinical Biochemistry, Verona, Italy
| | - Laura Pighi
- University of Verona, Section of Clinical Biochemistry, Verona, Italy
| | - Giuseppe Lippi
- University of Verona, Section of Clinical Biochemistry, Verona, Italy
| |
Collapse
|
13
|
Stokes W, Berenger BM, Venner AA, Deslandes V, Shaw JLV. Point of care molecular and antigen detection tests for COVID-19: current status and future prospects. Expert Rev Mol Diagn 2022; 22:797-809. [PMID: 36093682 DOI: 10.1080/14737159.2022.2122712] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Detection of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) has been critical to support and management of the COVID-19 pandemic. Point of care testing (POCT) for SARS-CoV-2 has been a widely used tool for detection of SARS-CoV-2. AREAS COVERED POCT nucleic acid amplification tests (NAATs) and rapid antigen tests (RATs) have been the most readily used POCT for SARS-CoV-2. Here, current knowledge on the utility of POCT NAATs and RATs for SARS-CoV-2 are reviewed and discussed alongside aspects of quality assurance factors that must be considered for successful and safe implementation of POCT. EXPERT OPINION Use cases for implementation of POCT must be evidence based, regardless of the test used. A quality assurance framework must be in place to ensure accuracy and safety of POCT.
Collapse
Affiliation(s)
- William Stokes
- Alberta Precision Laboratories, Alberta, Canada.,Department of Pathology and Laboratory Medicine, University of Alberta, Edmonton, Alberta, Canada
| | - Byron M Berenger
- Alberta Precision Laboratories, Alberta, Canada.,Department of Pathology and Laboratory Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Allison A Venner
- Alberta Precision Laboratories, Alberta, Canada.,Department of Pathology and Laboratory Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Vincent Deslandes
- Eastern Ontario Regional Laboratories Association, Ottawa, Ontario, Canada.,Department of Pathology and Laboratory Medicine, The Ottawa Hospital, Ottawa, Ontario, Canada.,Department of Pathology and Laboratory Medicine, The University of Ottawa, Ottawa, Ontario, Canada
| | - Julie L V Shaw
- Eastern Ontario Regional Laboratories Association, Ottawa, Ontario, Canada.,Department of Pathology and Laboratory Medicine, The Ottawa Hospital, Ottawa, Ontario, Canada.,Department of Pathology and Laboratory Medicine, The University of Ottawa, Ottawa, Ontario, Canada
| |
Collapse
|
14
|
Lippi G, Plebani M. Clinical Chemistry and laboratory medicine: enjoying the present and assessing the future. Clin Chem Lab Med 2022; 60:1313-1315. [PMID: 35822713 DOI: 10.1515/cclm-2022-0627] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Giuseppe Lippi
- Section of Clinical Biochemistry and School of Medicine, University of Verona, Verona, Italy
| | - Mario Plebani
- Department of Medicine-DIMED, University of Padova, Padova, Italy
| |
Collapse
|
15
|
Giberti I, Costa E, Domnich A, Ricucci V, De Pace V, Garzillo G, Guarona G, Icardi G. High Diagnostic Accuracy of a Novel Lateral Flow Assay for the Point-of-Care Detection of SARS-CoV-2. Biomedicines 2022; 10:biomedicines10071558. [PMID: 35884863 PMCID: PMC9312898 DOI: 10.3390/biomedicines10071558] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 06/27/2022] [Accepted: 06/29/2022] [Indexed: 12/27/2022] Open
Abstract
Highly accurate lateral flow immunochromatographic tests (LFTs) are an important public health tool to tackle the ongoing COVID-19 pandemic. The aim of this study was to assess the comparative diagnostic performance of the novel ND COVID-19 LFT under real-world conditions. A total of 400 nasopharyngeal swab specimens with a wide range of viral loads were tested in both reverse-transcription polymerase chain reaction and ND LFT. The overall sensitivity and specificity were 85% (95% CI: 76.7−90.7%) and 100% (95% CI: 98.7−100%), respectively. There was a clear association between the false-negative rate and sample viral load: the sensitivity parameters for specimens with cycle threshold values of <25 (>3.95 × 106 copies/mL) and ≥30 (≤1.29 × 105 copies/mL) were 100% and 50%, respectively. The performance was maximized in testing samples with viral loads ≥1.29 × 105 copies/mL. These findings suggest that the ND LFT is sufficiently accurate and useful for mass population screening programs, especially in high-prevalence and resource-constrained settings or during periods when the epidemic curve is rising. Other public health implications were also discussed.
Collapse
Affiliation(s)
- Irene Giberti
- Department of Health Sciences (DISSAL), University of Genoa, 16132 Genoa, Italy; (I.G.); (E.C.); (G.G.); (G.I.)
| | - Elisabetta Costa
- Department of Health Sciences (DISSAL), University of Genoa, 16132 Genoa, Italy; (I.G.); (E.C.); (G.G.); (G.I.)
| | - Alexander Domnich
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (V.R.); (V.D.P.); (G.G.)
- Correspondence:
| | - Valentina Ricucci
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (V.R.); (V.D.P.); (G.G.)
| | - Vanessa De Pace
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (V.R.); (V.D.P.); (G.G.)
| | - Giada Garzillo
- Department of Health Sciences (DISSAL), University of Genoa, 16132 Genoa, Italy; (I.G.); (E.C.); (G.G.); (G.I.)
| | - Giulia Guarona
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (V.R.); (V.D.P.); (G.G.)
| | - Giancarlo Icardi
- Department of Health Sciences (DISSAL), University of Genoa, 16132 Genoa, Italy; (I.G.); (E.C.); (G.G.); (G.I.)
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (V.R.); (V.D.P.); (G.G.)
| |
Collapse
|
16
|
Hörber S, Drees C, Ganzenmueller T, Schmauder K, Peter S, Biskup D, Peter A. Evaluation of a laboratory-based high-throughput SARS-CoV-2 antigen assay. Clin Chem Lab Med 2022; 60:1478-1485. [PMID: 35700973 DOI: 10.1515/cclm-2022-0360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 05/31/2022] [Indexed: 11/15/2022]
Abstract
OBJECTIVES Antigen tests are an essential part of SARS-CoV-2 testing strategies. Rapid antigen tests are easy to use but less sensitive compared to nucleic acid amplification tests (NAT) and less suitable for large-scale testing. In contrast, laboratory-based antigen tests are suitable for high-throughput immunoanalyzers. Here we evaluated the diagnostic performance of the laboratory-based Siemens Healthineers SARS-CoV-2 Antigen (CoV2Ag) assay. METHODS In a public test center, from 447 individuals anterior nasal swab specimens as well as nasopharyngeal swab specimens were collected. The nasal swab specimens were collected in sample inactivation medium and measured using the CoV2Ag assay. The nasopharyngeal swab specimens were measured by RT-PCR. Additionally, 9,046 swab specimens obtained for screening purposes in a tertiary care hospital were analyzed and positive CoV2Ag results confirmed by NAT. RESULTS In total, 234/447 (52.3%) participants of the public test center were positive for SARS-CoV-2-RNA. Viral lineage B1.1.529 was dominant during the study. Sensitivity and specificity of the CoV2Ag assay were 88.5% (95%CI: 83.7-91.9%) and 99.5% (97.4-99.9%), respectively. Sensitivity increased to 93.7% (97.4-99.9%) and 98.7% (97.4-99.9%) for swab specimens with cycle threshold values <30 and <25, respectively. Out of 9,046 CoV2Ag screening tests from hospitalized patients, 21 (0.2%) swab specimens were determined as false-positive by confirmatory NAT. CONCLUSIONS Using sample tubes containing inactivation medium the laboratory-based high-throughput CoV2Ag assay is a very specific and highly sensitive assay for detection of SARS-CoV-2 antigen in nasal swab specimens including the B1.1.529 variant. In low prevalence settings confirmation of positive CoV2Ag results by SARS-CoV-2-RNA testing is recommended.
Collapse
Affiliation(s)
- Sebastian Hörber
- Institute for Clinical Chemistry and Pathobiochemistry, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Tübingen, Germany
| | - Christoph Drees
- Institute for Clinical Chemistry and Pathobiochemistry, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Tübingen, Germany
| | - Tina Ganzenmueller
- Institute of Medical Virology, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Tübingen, Germany
| | - Kristina Schmauder
- Institute of Medical Microbiology and Hygiene, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Tübingen, Germany
| | - Silke Peter
- Institute of Medical Microbiology and Hygiene, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Tübingen, Germany
| | | | - Andreas Peter
- Institute for Clinical Chemistry and Pathobiochemistry, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Tübingen, Germany
| |
Collapse
|
17
|
Kost GJ. The Coronavirus Disease 2019 Spatial Care Path: Home, Community, and Emergency Diagnostic Portals. Diagnostics (Basel) 2022; 12:diagnostics12051216. [PMID: 35626375 PMCID: PMC9140623 DOI: 10.3390/diagnostics12051216] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 05/10/2022] [Accepted: 05/10/2022] [Indexed: 12/28/2022] Open
Abstract
This research uses mathematically derived visual logistics to interpret COVID-19 molecular and rapid antigen test (RAgT) performance, determine prevalence boundaries where risk exceeds expectations, and evaluate benefits of recursive testing along home, community, and emergency spatial care paths. Mathematica and open access software helped graph relationships, compare performance patterns, and perform recursive computations. Tiered sensitivity/specificity comprise: (T1) 90%/95%; (T2) 95%/97.5%; and (T3) 100%/≥99%, respectively. In emergency medicine, median RAgT performance peaks at 13.2% prevalence, then falls below T1, generating risky prevalence boundaries. RAgTs in pediatric ERs/EDs parallel this pattern with asymptomatic worse than symptomatic performance. In communities, RAgTs display large uncertainty with median prevalence boundary of 14.8% for 1/20 missed diagnoses, and at prevalence > 33.3−36.9% risk 10% false omissions for symptomatic subjects. Recursive testing improves home RAgT performance. Home molecular tests elevate performance above T1 but lack adequate validation. Widespread RAgT availability encourages self-testing. Asymptomatic RAgT and PCR-based saliva testing present the highest chance of missed diagnoses. Home testing twice, once just before mingling, and molecular-based self-testing, help avoid false omissions. Community and ER/ED RAgTs can identify contagiousness in low prevalence. Real-world trials of performance, cost-effectiveness, and public health impact could identify home molecular diagnostics as an optimal diagnostic portal.
Collapse
Affiliation(s)
- Gerald J Kost
- Fulbright Scholar 2020-2022, ASEAN Program, Point-of-Care Testing Center for Teaching and Research (POCT•CTR), Pathology and Laboratory Medicine, School of Medicine, University of California, Davis, CA 95616, USA
| |
Collapse
|
18
|
Keskin AU, Ciragil P, Topkaya AE. Clinical Accuracy of Instrument-Read SARS-CoV-2 Antigen Rapid Diagnostic Tests (Ag-IRRDTs). Int J Microbiol 2022; 2022:9489067. [PMID: 35586835 PMCID: PMC9110244 DOI: 10.1155/2022/9489067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 02/20/2022] [Accepted: 04/07/2022] [Indexed: 11/17/2022] Open
Abstract
This systematic review (PROSPERO registration number: CRD42021282476) aims to collect and analyse current evidence on real-world performance based on clinical accuracy of instrument-read rapid antigen diagnostic tests (Ag-IRRDTs) for SARS-CoV-2 identification. We used PRISMA Checklist and searched databases (PubMed, Web of Science Core Collection and FIND) for publications evaluating the accuracy of SARS-CoV-2 Ag-IRRDTs as of 30 September 2021, and included 40 independent clinical studies resulting in 48 Ag-IRRDT datasets with 137,770 samples. Across all datasets, pooled Ag-IRRDT sensitivity was 67.1% (95% CI: 65.9%-68.3%) and specificity was 99.4% with a tight CI. Pooled sensitivity and specificity of SARS-CoV-2 Ag-IRRDTs did not demonstrate a significant superiority over SARS-CoV-2 rapid antigen tests which do not require a reader instrument, even in the case where surveillance and screening datasets were excluded from the analysis. Nevertheless, they provide connectivity advantages and remove operator interface (in results-reading) issues. The lower sensitivity of certain brands of Ag-IRRDTs can be overcome in high prevalence areas with high frequency of testing. New SARS-CoV-2 variants are major concern for current and future diagnostic performance of these tests.
Collapse
Affiliation(s)
- Ali Umit Keskin
- Department of Biomedical Engineering, Yeditepe University, Istanbul, Turkey
| | - Pinar Ciragil
- Department of Microbiology, Yeditepe University Kozyatagi Hospital, Istanbul, Turkey
| | - Aynur Eren Topkaya
- Department of Microbiology, Yeditepe University Kosuyolu Hospital, Istanbul, Turkey
| |
Collapse
|
19
|
Lippi G, Henry BM, Adeli K. Diagnostic performance of the fully automated Roche Elecsys SARS-CoV-2 antigen electrochemiluminescence immunoassay: a pooled analysis. Clin Chem Lab Med 2022; 60:655-661. [PMID: 35114742 DOI: 10.1515/cclm-2022-0053] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Accepted: 01/21/2022] [Indexed: 12/28/2022]
Abstract
OBJECTIVES Among the diagnostic tests that have recently become commercially available for diagnosing coronavirus disease 2019 (COVID-19), the fully-automated Roche Elecsys severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen electrochemiluminescence immunoassay (ECLIA) is one of the most widespread for its adaptability within a system of laboratory automation, rapidity and high-throughput. This article is aimed to provide the results of the first pooled analysis of its accuracy for diagnosing SARS-CoV-2 infections. CONTENT We carried out an electronic search in Scopus and Medline, without language or date restrictions (i.e., up to January 18, 2022), to identify articles where the diagnostic performance of Roche Elecsys SARS-CoV-2 antigen ECLIA was compared with that of reference molecular diagnostic techniques. SUMMARY Overall, 11 studies were identified, 10 of which (n=6,095 swabs) provided necessary data for inclusion in a pooled analysis. The pooled diagnostic sensitivity, specificity and area under the curve (AUC) in nasopharyngeal samples were 0.68 (95%CI, 0.66-0.70), 0.99 (95%CI, 0.99-0.99) and 0.958 (95%CI, 0.936-0.980), respectively. The cumulative observed agreement with reference molecular assays was 89.5% and the kappa statistic was 0.735 (95%CI, 0.716-0.754). The pooled diagnostic sensitivity in samples with high viral load (i.e., cycle threshold values <28-30) was 0.95 (95%CI, 0.92-0.97). OUTLOOK The results of this pooled analysis confirm that the fully-automated Roche Elecsys SARS-CoV-2 antigen ECLIA has high diagnostic specificity and optimal diagnostic sensitivity for identifying nasopharyngeal samples with higher viral load, thus making it a reliable technique for mass screening and for supporting strategies based on shorten isolation and/or quarantine.
Collapse
Affiliation(s)
- Giuseppe Lippi
- IFCC Task Force on COVID-19, Milan, Italy
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| | - Brandon M Henry
- IFCC Task Force on COVID-19, Milan, Italy
- Cardiac Intensive Care Unit, The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
- Disease Intervention & Prevention and Population Health Programs, Texas Biomedical Research Institute, San Antonio, TX, USA
| | - Khosrow Adeli
- IFCC Task Force on COVID-19, Milan, Italy
- Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
20
|
Lippi G, Favresse J, Gromiha MM, SoRelle JA, Plebani M, Henry BM. Ad interim recommendations for diagnosing SARS-CoV-2 infection by the IFCC SARS-CoV-2 variants working group. Clin Chem Lab Med 2022; 60:975-981. [PMID: 35452576 DOI: 10.1515/cclm-2022-0345] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2022] [Accepted: 04/10/2022] [Indexed: 12/28/2022]
Abstract
This document, endorsed by the IFCC Working Group on SARS-CoV-2 Variants, aims to update previous indications for diagnosing acute SARS-CoV-2 infection, taking into consideration the evidence that has emerged after the origin and spread of new lineages and sub-lineages of the virus characterized by mutated genetics and altered biochemical, biological and clinical characteristics. These indications encompass the use of different diagnostic strategies in specific clinical settings, such as high risk of SARS-CoV-2 infection (symptomatic patients), low risk of SARS-CoV-2 infection (asymptomatic subjects) at hospital admission/contact tracing, testing in asymptomatic subjects, in epidemiologic surveys and/or population screening, along with tentative indications for identification of new lineages and/or sub-lineages of SARS-CoV-2.
Collapse
Affiliation(s)
- Giuseppe Lippi
- IFCC SARS-CoV-2 Variants Working Group, Verona, Italy
- IFCC Task Force on COVID-19, Verona, Italy
- Section of Clinical Biochemistry and School of Medicine, University of Verona, Verona, Italy
| | - Julien Favresse
- IFCC SARS-CoV-2 Variants Working Group, Verona, Italy
- Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium
| | - Michael M Gromiha
- IFCC SARS-CoV-2 Variants Working Group, Verona, Italy
- Department of Biotechnology, Bhupat and Jyoti Mehta School of Biosciences, Indian Institute of Technology Madras, Chennai, India
| | - Jeffrey A SoRelle
- IFCC SARS-CoV-2 Variants Working Group, Verona, Italy
- Department of Pathology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Mario Plebani
- IFCC SARS-CoV-2 Variants Working Group, Verona, Italy
- Department of Medicine-DIMED, University of Padova, Padova, Italy
| | - Brandon M Henry
- IFCC SARS-CoV-2 Variants Working Group, Verona, Italy
- Clinical Laboratory, Division of Nephrology and Hypertension, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| |
Collapse
|
21
|
Lippi G, Henry BM, Plebani M. LumiraDX SARS-CoV-2 Antigen Test for Diagnosing Acute SARS-CoV-2 Infection: Critical Literature Review and Meta-Analysis. Diagnostics (Basel) 2022; 12:diagnostics12040947. [PMID: 35453996 PMCID: PMC9027501 DOI: 10.3390/diagnostics12040947] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 04/08/2022] [Accepted: 04/08/2022] [Indexed: 12/20/2022] Open
Abstract
We present here a critical literature review and meta-analysis on the accuracy of the LumiraDX SARS-CoV-2 Antigen Test for diagnosing acute SARS-CoV-2 infection. An electronic search was conducted in the Scopus and Medline databases using the keywords “LumiraDX” AND “COVID-19” OR “SARS-CoV-2”, without date (i.e., up to 1 February 2022) or language restrictions, for detecting clinical studies where the diagnostic accuracy of the LumiraDX SARS-CoV-2 Antigen Test was compared with reference molecular diagnostic methods. All studies where the rates of true positive, true negative, false positive and false negative cases were available for constructing a 2 × 2 table and providing pooled estimates of diagnostic sensitivity, specificity and accuracy were included in a pooled analysis. The study was conducted in accordance with the PRISMA (preferred reporting items for systematic reviews and meta-analyses) reporting checklist. Eleven studies (n = 8527 samples) could be included in our pooled analysis, while five additional documents provided diagnostic accuracy data but could not be extracted for construction of a 2 × 2 table. The pooled diagnostic sensitivity and specificity were 0.86 (95%CI, 0.84–0.88) and 0.99 (95%CI, 0.98–0.99), respectively, while the area under the summary receiver operating characteristic curve was 0.974 (95%CI, 0.965–0.983) and the agreement was 96.8% (95%CI, 96.4–97.1%), with kappa statistics of 0.87 (95%CI, 0.85–0.88). In conclusion, the diagnostic performance of the LumiraDX SARS-CoV-2 Antigen Test would allow the conclusion that it may be seen as a reliable alternative to molecular testing for the rapid preliminary screening of acute SARS-CoV-2 infections.
Collapse
Affiliation(s)
- Giuseppe Lippi
- Section of Clinical Biochemistry and School of Medicine, University of Verona, 37134 Verona, Italy
- Correspondence: ; Tel.: +39-045-8122970; Fax: +39-045-8124308
| | - Brandon M. Henry
- Cardiac Intensive Care Unit, The Heart Institute, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH 45229, USA;
- Disease Intervention & Prevention and Population Health Programs, Texas Biomedical Research Institute, San Antonio, TX 78245, USA
| | - Mario Plebani
- Department of Medicine—DIMED, University of Padova, 35100 Padova, Italy;
| |
Collapse
|
22
|
Barry G, McCarney C, Farrelly M, Breathnach R, Mooney C, More SJ. Rapid antigen testing for SARS-CoV-2 infection in a university setting in Ireland: Learning from a 6-week pilot study. PUBLIC HEALTH IN PRACTICE 2022; 3:100255. [PMID: 35403074 PMCID: PMC8976698 DOI: 10.1016/j.puhip.2022.100255] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 03/29/2022] [Accepted: 03/30/2022] [Indexed: 11/25/2022] Open
Abstract
Objectives Study design Methods Results Conclusions
Collapse
|
23
|
Lippi G, Henry BM, Adeli K, Plebani M. Fujirebio Lumipulse SARS-CoV-2 antigen immunoassay: pooled analysis of diagnostic accuracy. Diagnosis (Berl) 2022; 9:149-156. [PMID: 35287253 DOI: 10.1515/dx-2022-0021] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Accepted: 02/28/2022] [Indexed: 12/15/2022]
Abstract
We provide here a pooled analysis of accuracy of Fujirebio Lumipulse SARS-CoV-2 Antigen chemiluminescent immunoassay for diagnosing acute SARS-CoV-2 infections. An electronic search was conducted in Scopus and Medline with the keywords "Lumipulse" AND "antigen" AND "SARS-CoV-2" or "COVID-19", up to January 21, 2022, for identifying clinical investigations (minimum sample size ≥100) where diagnostic accuracy of Lumipulse G SARS-CoV-2 Ag was tested against reference molecular techniques. All studies which allowed to construct a 2 × 2 table were included in a pooled analysis. A final number of 21 studies, totalling 17,648 nasopharyngeal and 8538 saliva specimens, were finally included. The pooled diagnostic sensitivity and specificity in nasopharyngeal swabs were 0.80 (95%CI, 0.78-0.81) and 0.98 (95%CI, 0.97-0.98), respectively, whilst the area under the curve and agreement were 0.980 (95%CI, 0.973-0.986) and 94.9%, respectively. In the twelve studies which used the fixed 1.34 pg/mL currently recommended manufacturer's threshold, the diagnostic accuracy remained unvaried. In saliva samples, the pooled diagnostic sensitivity and specificity were 0.75 (95%CI, 0.36-0.62) and 1.00 (95%CI, 0.99-1.00), respectively, whilst the area under the curve and were 0.976 (95%CI, 0.969-0.984) and 98.4%, respectively. In the five studies which used the fixed 0.67 pg/mL currently recommended manufacturer's threshold, the diagnostic accuracy remained unvaried. In conclusion, Lumipulse G SARS-CoV-2 Ag assay demonstrates good diagnostic sensitivity and specificity, thus representing a valuable complementary and integrative option to molecular testing for SARS-CoV-2 in the current pandemic.
Collapse
Affiliation(s)
- Giuseppe Lippi
- IFCC Task Force on COVID-19, Milan, Italy.,Section of Clinical Biochemistry, University of Verona, Verona, Italy
| | - Brandon M Henry
- IFCC Task Force on COVID-19, Milan, Italy.,Clinical Laboratory, Division of Nephorlogy and Hypertension, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA.,Disease Intervention & Prevention and Population Health Programs, Texas Biomedical Research Institute, San Antonio, TX, USA
| | - Khosrow Adeli
- IFCC Task Force on COVID-19, Milan, Italy.,Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada
| | - Mario Plebani
- Department of Medicine-DIMED, University of Padova, Padova, Italy
| |
Collapse
|
24
|
Clinical performance of the Roche Elecsys SARS-CoV-2 antigen fully automated electrochemiluminescence immunoassay. Pract Lab Med 2022; 29:e00265. [PMID: 35071720 PMCID: PMC8760093 DOI: 10.1016/j.plabm.2022.e00265] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Accepted: 01/12/2022] [Indexed: 01/08/2023] Open
Abstract
Objective We assessed the clinical performance of novel Roche Elecsys SARS-CoV-2 Antigen fully automated electrochemiluminescence immunoassay (ECLIA). Design and methods We tested 160 subjects, 110 (68.8%), with positive molecular test for SARS-CoV-2 infection in nasopharyngeal samples, with Altona Diagnostics RealStar SARS-CoV-2 RT-PCR Kit and Roche Elecsys SARS-CoV-2 Antigen. Results Highly significant correlation was found between Elecsys SARS-CoV-2 Antigen ECLIA and cycle threshold (Ct) values of SARS-CoV-2 S and E genes (both r = −0.91; p < 0.001). The area under the curve (AUC), sensitivity and specificity of Elecsys SARS-CoV-2 Antigen ECLIA were 0.83, 0.43 and 1.00 in all samples, 0.99, 0.87 and 0.99 in those with both Ct values < 30, as well as 1.00, 1.00 and 0.89 in samples with both Ct values < 25. Conclusion Roche Elecsys SARS-CoV-2 Antigen ECLIA may be a surrogate of molecular testing for identification of super-spreaders.
Collapse
|
25
|
FebriDx for rapid screening of patients with suspected COVID-19 upon hospital admission: systematic literature review and meta-analysis. J Hosp Infect 2022; 123:61-66. [PMID: 35202747 PMCID: PMC8858770 DOI: 10.1016/j.jhin.2022.02.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2022] [Revised: 02/10/2022] [Accepted: 02/13/2022] [Indexed: 12/30/2022]
Abstract
A systematic literature review and meta-analysis was undertaken of the lateral flow-based FebriDx immunoassay for triaging patients with suspected coronavirus disease 2019 (COVID-19) upon admission to healthcare facilities. An electronic search was conducted in Scopus and Medline using the keywords ‘FebriDx’ AND ‘COVID-19’ OR ‘SARS-CoV-2’, with no language or date (i.e. up to 4th February 2022) limits, selecting studies where FebriDx was used for triaging patients with suspected COVID-19 in acute care settings, and reporting sufficient data to construct a 2×2 table. Five studies were included in the final analysis, totalling 2309 patients. The pooled diagnostic sensitivity and specificity were 0.91 [95% confidence interval (CI) 0.88–0.93] and 0.92 (95% CI 0.90–0.93), whilst the area under the curve, accuracy and kappa statistics were 0.971 (95% CI 0.962–0.980), 91.4% (95% CI 90.2–92.5%) and 0.762 (95% CI 0.731–0.793), respectively, thus reflecting substantial agreement with reference molecular testing techniques. Negative and positive predictive values were 0.974 (95% CI 0.966–0.981) and 0.742 (95% CI 0.711–0.770), respectively. This pooled analysis demonstrated that FebriDx has clinical value for rapid screening of patients with suspected COVID-19 in acute care settings, especially in regions with high viral circulation in which the pre-test probability is high, and enables prioritization for confirmatory laboratory testing.
Collapse
|
26
|
Tonelotto V, Davini A, Cardarelli L, Calderone M, Marin P. Efficacy of Fluorecare SARS-CoV-2 Spike Protein Test Kit for SARS-CoV-2 detection in nasopharyngeal samples of 121 individuals working in a manufacturing company. PLoS One 2022; 17:e0262174. [PMID: 35025944 PMCID: PMC8757945 DOI: 10.1371/journal.pone.0262174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 12/17/2021] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVES The aim of this study was to evaluate the clinical performance of the Fluorecare SARS-CoV-2 Spike Protein Test Kit, a rapid immunochromatographic assay for SARS-CoV-2 detection. Moreover, we sought to point out the strategy adopted by a local company to lift the lockdown without leading to an increase in the number of COVID-19 cases, by performing a precise and timely health surveillance. METHODS The rapid Fluorecare SARS-CoV-2 Spike Protein Test was performed immediately after sampling following the manufacturer's instructions. RT-PCRs were performed within 24 hours of specimen collection. A total amount of 253 nasopharyngeal samples from 121 individuals were collected between March 16 and April 2, 2021 and tested. RESULTS Of 253 nasopharyngeal samples, 11 (9.1%) were positive and 242 (90.9%) were negative for SARS-CoV-2 RNA by RT-PCR assays. The rapid SARS-CoV-2 antigen detection test's mean sensitivity and specificity were 84,6% (95% CI, 54.6-98.1%) and 100% (95% CI, 98.6-100%), respectively. Two false negative test results were obtained from samples with high RT-PCR cycle threshold (Ct). CONCLUSION Our study suggested that Fluorecare SARS-CoV-2 Spike Protein Test can be introduced into daily diagnostic practice, as its mean sensitivity and specificity follow the standards recommended by WHO and IFCC Task Force. In addition, we underlined how the strategy adopted by a local company to risk assessment and health surveillance was appropriate for infection containment. This real-life scenario gave us the possibility to experience potential approaches aimed to preserve public health and work activities.
Collapse
Affiliation(s)
| | - Annamaria Davini
- C.M.S.R. Veneto Medica S.r.l., Altavilla Vicentina, Vicenza, Italy
| | - Laura Cardarelli
- Lifebrain S.r.l–Gruppo Cerba HealthCare c/o RDI—Rete Diagnostica Italiana S.r.l, Limena, Padova, Italy
| | - Milena Calderone
- C.M.S.R. Veneto Medica S.r.l., Altavilla Vicentina, Vicenza, Italy
| | - Paola Marin
- C.M.S.R. Veneto Medica S.r.l., Altavilla Vicentina, Vicenza, Italy
| |
Collapse
|
27
|
Lippi G, Nocini R, Brandon HM. Critical literature review and pooled analysis of diagnostic accuracy of Ortho VITROS SARS-CoV-2 antigen test for diagnosing acute SARS-CoV-2 infections. J Med Biochem 2022; 41:540-548. [PMCID: PMC9618338 DOI: 10.5937/jomb0-36107] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 02/15/2022] [Indexed: 11/12/2022] Open
Abstract
Background: The present study is aimed at reviewing and meta-analyzing the currently published data on the diagnostic accuracy of Ortho VITROS SARS-CoV-2 antigen test for diagnosing acute SARS-CoV-2 infections. Methods: An electronic search was conducted in Scopus and Medline with the keywords "VITROS" AND "antigen" AND "COVID-19" OR "SARS-CoV-2" AND "immunoassay" within the search fields "TITLE" AND "ABSTRACT" AND "KEYWORDS", without no date (i.e., up to January 23, 2022) or language restrictions, aimed at detecting documents reporting the diagnostic accuracy of this SARSCoV-2 immunoassay compared with reference molecular diagnostic methods. Results: Overall, 5 studies (n=2734 samples) were finally included in our pooled analysis, four of which also provided diagnostic sensitivity in oro-and nasopharyngeal samples with high viral load. The pooled cumulative diagnostic sensitivity and specificity were 0.82 (95%CI, 0.78-0.86) and 1.00 (95%CI, 1.00-1.00), respectively, whilst the area under the curve was 0.995 (95%CI, 0.993-0.997), the cumulative agreement 97.2% (95%CI, 96.5-97.8%), with 0.89 (95%CI, 0.86-0.91) kappa statistics, thus reflecting an almost perfect concordance with reference molecular biology techniques. The pooled diagnostic sensitivity in samples with high viral load was as high as 0.98 (95%CI, 0.96-0.99). Conclusions: These results confirm that the automated and high-throughput Ortho VITROS SARS-CoV-2 antigen test may represent a valuable surrogate of molecular testing for diagnosing acute SARS-CoV-2 infections, especially in subjects with high viral load.
Collapse
Affiliation(s)
- Giuseppe Lippi
- University of Verona, Section of Clinical Biochemistry and School of Medicine, Verona, Italy
| | - Riccardo Nocini
- University of Verona, Department of Surgery, Dentistry, Paediatrics and Gynaecology, Unit of Otorhinolaryngology, Verona, Italy
| | - Henry M. Brandon
- The Heart Institute, Cincinnati Children's Hospital Medical Center, Cardiac Intensive Care Unit, Cincinnati, OH, United States of America
| |
Collapse
|
28
|
García-Salguero C, Culebras E, Merino P, Baos E, Delgado-Iribarren A. Usefulness of SARS-CoV-2 antigen test sample as input for SARS-CoV-2 RT-PCR analysis. J Med Virol 2021; 94:1693-1695. [PMID: 34786737 PMCID: PMC8661811 DOI: 10.1002/jmv.27459] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 11/12/2021] [Accepted: 11/15/2021] [Indexed: 01/02/2023]
Abstract
SARS‐CoV‐2 rapid detection is of great interest to prevent viral dissemination. In that sense, antigen tests appeared as a very valuable tool to reach this goal. However, it is possible to obtain a negative result in those patients with low viral loads, and consequently, reverse transcription‐polymerase chain reaction (RT‐PCR) should be performed on samples from patients with a negative antigen test in which there is a strong suspicion of COVID infection. The common diagnostic algorithm involves taking a second sample for RT‐PCR testing. This study evaluates the usefulness of the antigen test sample for carrying out RT‐PCR analysis when necessary. Results obtained indicate that can be used a unique sample for both antigen test and RT‐PCR. This data showed that it is possible to reduce excessive suspected individuals managing and so on increase staff security and patient comfort.
Collapse
Affiliation(s)
| | - Esther Culebras
- Department of Clinical Microbiology, IML and IdISSC, Hospital Clínico San Carlos, Madrid, Spain.,Department of Medicine, Facultad de Medicina, Universidad Complutense, Madrid, Spain
| | - Paloma Merino
- Department of Clinical Microbiology, IML and IdISSC, Hospital Clínico San Carlos, Madrid, Spain.,Department of Medicine, Facultad de Medicina, Universidad Complutense, Madrid, Spain
| | - Elvira Baos
- Department of Clinical Microbiology, IML and IdISSC, Hospital Clínico San Carlos, Madrid, Spain
| | - Alberto Delgado-Iribarren
- Department of Clinical Microbiology, IML and IdISSC, Hospital Clínico San Carlos, Madrid, Spain.,Department of Medicine, Facultad de Medicina, Universidad Complutense, Madrid, Spain
| |
Collapse
|
29
|
Durner J, Beikler T, Watts DC, Becker M, Draenert ME. SARS-CoV-2 and regular patient treatment - from the use of rapid antigen testing up to treatment specific precaution measures. Head Face Med 2021; 17:39. [PMID: 34481505 PMCID: PMC8417659 DOI: 10.1186/s13005-021-00289-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Accepted: 08/24/2021] [Indexed: 11/10/2022] Open
Abstract
INTRODUCTION The COVID-19 pandemic poses a continued challenge for all parties involved especially for the dentist as routine operation must be resumed. Rapid Antigen Tests (RATs) are actually recommended to identify and minimize infectious risks. However, there is still no guideline on the implementation of RATs in a dental or medical setting. METHODS Based on data and an extensive literature research regarding rapid antigen testing and reflecting the recommendations given by the various professional societies a task force was formed to determine a specific testing and treatment strategy. RESULTS A comprehensive test and treatment strategy and risk analysis was developed with practical suggestions for a wide range of typical activities in dental and medical offices. The transmission of SARS-CoV-2 and its variants via aerosols and droplets as well as the difficulties to maintain the minimum distance form special challenges to the dental routine. RATs might in addition to optimal and necessary hygienic standards in combination with the use of adequate personal protection equipment be an important instrument in managing the challenges. CONCLUSIONS The present work gives recommendations for dental routine operation (dental practices, outpatient clinics) to provide the necessary dental care for the population while protecting the doctor, practice team and patient at the same time.
Collapse
Affiliation(s)
- Jürgen Durner
- Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Ludwig-Maximilians-University Munich, Goethestr. 70, Goethestraße 70, 80336, Munich, Germany.
- Laboratory Becker & Colleagues, Führichstr. 70, 81671, Munich, Germany.
| | - Thomas Beikler
- Department of Periodontics, Preventive and Restorative Dentistry, University Medical Center Hamburg-Eppendorf, Martinistraße 52 (Building O58), 20246, Hamburg, Germany
| | - David C Watts
- School of Medical Sciences and Photon Science Institute, University of Manchester, Manchester, UK
| | - Marc Becker
- Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Ludwig-Maximilians-University Munich, Goethestr. 70, Goethestraße 70, 80336, Munich, Germany
- Laboratory Becker & Colleagues, Führichstr. 70, 81671, Munich, Germany
| | - Miriam E Draenert
- Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Ludwig-Maximilians-University Munich, Goethestr. 70, Goethestraße 70, 80336, Munich, Germany
| |
Collapse
|
30
|
Salvagno GL, Nocini R, Gianfilippi G, Fiorio G, Pighi L, De Nitto S, Cominziolli A, Henry BM, Lippi G. Performance of Fujirebio Espline SARS-CoV-2 rapid antigen test for identifying potentially infectious individuals. Diagnosis (Berl) 2021; 9:146-148. [PMID: 34411471 DOI: 10.1515/dx-2021-0107] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 08/05/2021] [Indexed: 11/15/2022]
Affiliation(s)
- Gian Luca Salvagno
- Section of Clinical Biochemistry, University of Verona, Verona, Italy.,Service of Laboratory Medicine, Pederzoli Hospital, Peschiera del Garda, Italy
| | - Riccardo Nocini
- Department of Surgery, Dentistry, Paediatrics and Gynaecology, University of Verona, Verona, Italy
| | | | - Giacomo Fiorio
- Medical Direction, Pederzoli Hospital, Peschiera del Garda, Italy
| | - Laura Pighi
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| | - Simone De Nitto
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| | - Annalisa Cominziolli
- Department of Surgery, Dentistry, Paediatrics and Gynaecology, University of Verona, Verona, Italy
| | - Brandon M Henry
- The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Giuseppe Lippi
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| |
Collapse
|
31
|
Salvagno GL, Gianfilippi G, Pighi L, De Nitto S, Henry BM, Lippi G. Real-world assessment of Fluorecare SARS-CoV-2 Spike Protein Test Kit. ADVANCES IN LABORATORY MEDICINE 2021; 2:409-416. [PMID: 37362410 PMCID: PMC10197504 DOI: 10.1515/almed-2021-0041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Accepted: 05/03/2021] [Indexed: 06/28/2023]
Abstract
Objectives Since commercial SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) antigen rapid detection tests (Ag-RDTs) display broad diagnostic efficiency, this study aimed to evaluate the clinical performance of Fluorecare SARS-CoV-2 Spike Protein Test Kit in a real-life scenario. Methods The study population consisted of a series of patients undergoing SARS-Cov-2 diagnostic testing at Pederzoli Hospital of Peschiera del Garda (Verona, Italy). A nasopharyngeal swab was collected upon hospital admission and assayed with molecular (Altona Diagnostics RealStar® SARSCoV-2 RT-PCR Kit) and antigen (Fluorecare SARS-CoV-2 Spike Protein Test Kit) tests. Results The study population consisted of 354 patients (mean age, 47 ± 20 years; 195 women, 55.1%), 223 (65.8%) positive at molecular testing. A significant correlation was found between Fluorecare SARS-CoV-2 Spike Protein Test Kit and Altona (both S and E genes: r=-0.75; p<0.001). The cumulative area under the curve in all nasopharyngeal samples was 0.68. At ≥1.0 S/CO manufacturer's cut-off, the sensitivity, specificity, negative and positive predictive values were 27.5, 99.2, 41.5 and 98.5%, respectively. Considerable improvement of sensitivity was observed as Ct values decreased, becoming 66.7% in samples with mean Ct values <30, 90.5% in those with mean Ct values <25, up to 100% in those with mean Ct values <20. Conclusions The modest sensitivity and negative predictive value of Fluorecare SARS-CoV-2 Spike Protein Test Kit makes unadvisable to use this assay as surrogate of molecular testing for definitively diagnosing SARS-CoV-2 infection, though its suitable sensitivity at high viral load could make it a reliable screening test for patients with higher infective potential.
Collapse
Affiliation(s)
- Gian Luca Salvagno
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
- Service of Laboratory Medicine, Pederzoli Hospital, Peschiera del Garda, Italy
| | | | - Laura Pighi
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| | - Simone De Nitto
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| | - Brandon M. Henry
- The Heart Institute, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
| | - Giuseppe Lippi
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| |
Collapse
|
32
|
Hartard C, Berger S, Josse T, Schvoerer E, Jeulin H. Performance evaluation of an automated SARS-CoV-2 Ag test for the diagnosis of COVID-19 infection on nasopharyngeal swabs. Clin Chem Lab Med 2021; 59:2003-2009. [PMID: 34331847 DOI: 10.1515/cclm-2021-0569] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Accepted: 07/21/2021] [Indexed: 12/19/2022]
Abstract
OBJECTIVES The detection of SARS-CoV-2 in infected people is a key tool to help in controlling COVID-19 pandemic. Like rapid antigenic tests, automated antigen tests, that present the advantage of a higher throughput flow, may be of interest. The LIAISON® SARS-CoV-2 Ag test was evaluated for the quantification of SARS-CoV-2 nucleocapsid antigen in nasopharyngeal swabs by comparison to RT-PCR. METHODS The study involved 378 nasopharyngeal samples (UTM® and FLOQSwab™, Copan Diagnostics), including 46 swabs positive for SARS-CoV-2 by RT-PCR. These samples came from asymptomatic (n=99, 26.2%) or symptomatic people (n=279, 73.8%), at different times from symptom onset. The samples were analyzed on LIAISON® XL. RESULTS The overall specificity was 99.4% (CI95% [98.6-100]). The negative predictive value reached 100% in asymptomatic people. Among the 46 positive samples, the overall sensitivity was 84.8% (CI95% [74.4-95.2]), reached 91.9% (CI95% [83.1-100]) in the first fourth days after symptoms onset and was 100% for Cq values ≤25. Antigen was not detected in samples with Cq values >25. Similar results were observed on nasopharyngeal swabs coming from patients infected with the 20I/501Y.V1 variant or the 20H/501Y.V2 variant. CONCLUSIONS According to technical performances, the LIAISON® SARS-CoV-2 Ag test may be a useful tool for COVID-19 diagnosis, especially during the first four days of symptoms.
Collapse
Affiliation(s)
- Cédric Hartard
- Université de Lorraine, CNRS, LCPME, Nancy, France
- Laboratoire de Virologie, CHRU de Nancy Brabois, Vandoeuvre-lès-Nancy, France
| | - Sibel Berger
- Plateforme de Génomique Microbienne, CHRU de Nancy Brabois, Vandoeuvre-lès-Nancy, France
| | - Thomas Josse
- Plateforme de Génomique Microbienne, CHRU de Nancy Brabois, Vandoeuvre-lès-Nancy, France
| | - Evelyne Schvoerer
- Université de Lorraine, CNRS, LCPME, Nancy, France
- Laboratoire de Virologie, CHRU de Nancy Brabois, Vandoeuvre-lès-Nancy, France
| | - Hélène Jeulin
- Université de Lorraine, CNRS, LCPME, Nancy, France
- Laboratoire de Virologie, CHRU de Nancy Brabois, Vandoeuvre-lès-Nancy, France
| |
Collapse
|
33
|
Wagenhäuser I, Knies K, Rauschenberger V, Eisenmann M, McDonogh M, Petri N, Andres O, Flemming S, Gawlik M, Papsdorf M, Taurines R, Böhm H, Forster J, Weismann D, Weißbrich B, Dölken L, Liese J, Kurzai O, Vogel U, Krone M. Clinical performance evaluation of SARS-CoV-2 rapid antigen testing in point of care usage in comparison to RT-qPCR. EBioMedicine 2021; 69:103455. [PMID: 34186490 PMCID: PMC8234263 DOI: 10.1016/j.ebiom.2021.103455] [Citation(s) in RCA: 52] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 06/07/2021] [Accepted: 06/07/2021] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Antigen rapid diagnostic tests (RDT) for SARS-CoV-2 are fast, broadly available, and inexpensive. Despite this, reliable clinical performance data from large field studies is sparse. METHODS In a prospective performance evaluation study, RDT from three manufacturers (NADAL®, Panbio™, MEDsan®, conducted on different samples) were compared to quantitative reverse transcription polymerase chain reaction (RT-qPCR) in 5 068 oropharyngeal swabs for detection of SARS-CoV-2 in a hospital setting. Viral load was derived from standardised RT-qPCR Cycle threshold (Ct) values. The data collection period ranged from November 12, 2020 to February 28, 2021. FINDINGS The sensitivity of RDT compared to RT-qPCR was 42·57% (95% CI 33·38%-52·31%). The specificity was 99·68% (95% CI 99·48%-99·80%). Sensitivity declined with decreasing viral load from 100% in samples with a deduced viral load of ≥108 SARS-CoV-2 RNA copies per ml to 8·82% in samples with a viral load lower than 104 SARS-CoV-2 RNA copies per ml. No significant differences in sensitivity or specificity could be observed between samples with and without spike protein variant B.1.1.7. The NPV in the study cohort was 98·84%; the PPV in persons with typical COVID-19 symptoms was 97·37%, and 28·57% in persons without or with atypical symptoms. INTERPRETATION RDT are a reliable method to diagnose SARS-CoV-2 infection in persons with high viral load. RDT are a valuable addition to RT-qPCR testing, as they reliably detect infectious persons with high viral loads before RT-qPCR results are available. FUNDING German Federal Ministry for Education and Science (BMBF), Free State of Bavaria.
Collapse
Affiliation(s)
- Isabell Wagenhäuser
- Institute for Hygiene and Microbiology, University of Wuerzburg, Josef-Schneider-Str. 2 / E1, Wuerzburg 97080, Germany
| | - Kerstin Knies
- Institute for Virology and Immunobiology, University of Wuerzburg, Wuerzburg, Germany
| | | | - Michael Eisenmann
- Infection Control Unit, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Miriam McDonogh
- Department of Orthopaedic Trauma, Hand, Plastic and Reconstructive Surgery, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Nils Petri
- Department of Internal Medicine I, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Oliver Andres
- Department of Paediatrics, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Sven Flemming
- Department of General, Visceral, Transplantation, Vascular and Paediatric Surgery, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Micha Gawlik
- Department of Psychiatry and Psychotherapy, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Michael Papsdorf
- Department of Obstetrics and Gynaecology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Regina Taurines
- Department of Child and Adolescent Psychiatry, Psychosomatics and Psychotherapy, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Hartmut Böhm
- Department of Oral and Maxillofacial Surgery, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Johannes Forster
- Institute for Hygiene and Microbiology, University of Wuerzburg, Josef-Schneider-Str. 2 / E1, Wuerzburg 97080, Germany
| | - Dirk Weismann
- Department of Internal Medicine I, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Benedikt Weißbrich
- Institute for Virology and Immunobiology, University of Wuerzburg, Wuerzburg, Germany
| | - Lars Dölken
- Institute for Virology and Immunobiology, University of Wuerzburg, Wuerzburg, Germany
| | - Johannes Liese
- Department of Paediatrics, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Oliver Kurzai
- Institute for Hygiene and Microbiology, University of Wuerzburg, Josef-Schneider-Str. 2 / E1, Wuerzburg 97080, Germany; Leibniz Institute for Natural Product Research and Infection Biology - Hans-Knoell-Institute, Jena, Germany
| | - Ulrich Vogel
- Institute for Hygiene and Microbiology, University of Wuerzburg, Josef-Schneider-Str. 2 / E1, Wuerzburg 97080, Germany; Infection Control Unit, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Manuel Krone
- Institute for Hygiene and Microbiology, University of Wuerzburg, Josef-Schneider-Str. 2 / E1, Wuerzburg 97080, Germany; Infection Control Unit, University Hospital Wuerzburg, Wuerzburg, Germany; Department of Internal Medicine I, University Hospital Wuerzburg, Wuerzburg, Germany.
| |
Collapse
|