1
|
Casas-Barragán A, Molina F, Tapia-Haro RM, Martínez-Martos JM, Ramírez-Expósito MJ, Rus A, Correa-Rodríguez M, Aguilar-Ferrándiz ME. Different Correlation Patterns Between Circulating Amino Acids and Body Temperature in Fibromyalgia Syndrome: A Cross-Sectional Study. Int J Mol Sci 2024; 25:13517. [PMID: 39769280 PMCID: PMC11676748 DOI: 10.3390/ijms252413517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2024] [Revised: 12/07/2024] [Accepted: 12/13/2024] [Indexed: 01/11/2025] Open
Abstract
The aim of this study was to analyze the association between circulating amino acids and central and peripheral body temperature in subjects with and without fibromyalgia syndrome (FMS). A total of 47 patients with FMS and 59 healthy subjects were included in the study. The concentration of amino acids was determined in serum samples using a fluorimeter coupled with a high-performance liquid chromatography system. An infrared thermography camera was used to estimate peripheral hand temperatures. The core temperature of the body was estimated using an infrared thermometer, which was applied to the axillary and tympanic areas. Correlations between several thermographic variables of the hands and tryptophan, methionine, 3-methylhistidine, histidine, glutamic acid, and tyrosine were identified exclusively within the FMS group. In contrast, correlations between aminoadipic acid and serine and thermographic variables were observed only in the healthy control group. The concentrations of asparagine and lysine correlated with thermographic variables in both groups. The essential amino acid leucine was found to correlate with axillary temperature in FMS patients. However, it should be noted that the observed associations between aminoadipic acid and tryptophan blood concentrations and axillary temperature were limited to the control group. Several correlations were identified between circulating amino acids and different body temperatures in both healthy controls and patients with FMS. However, the correlation pattern differs significantly between FMS patients and healthy controls. These findings suggest the possibility of a change in the function of several amino acids in the thermoregulatory process in patients with FMS.
Collapse
Affiliation(s)
- Antonio Casas-Barragán
- Department of Physical Therapy, Faculty of Health Sciences, University of Granada (UGR), 18071 Granada, Spain; (A.C.-B.); (F.M.); (R.M.T.-H.); (M.E.A.-F.)
- Instituto de Investigación Biosanitaria ibs.GRANADA, 18012 Granada, Spain;
| | - Francisco Molina
- Department of Physical Therapy, Faculty of Health Sciences, University of Granada (UGR), 18071 Granada, Spain; (A.C.-B.); (F.M.); (R.M.T.-H.); (M.E.A.-F.)
- Instituto de Investigación Biosanitaria ibs.GRANADA, 18012 Granada, Spain;
| | - Rosa María Tapia-Haro
- Department of Physical Therapy, Faculty of Health Sciences, University of Granada (UGR), 18071 Granada, Spain; (A.C.-B.); (F.M.); (R.M.T.-H.); (M.E.A.-F.)
- Instituto de Investigación Biosanitaria ibs.GRANADA, 18012 Granada, Spain;
| | | | | | - Alma Rus
- Instituto de Investigación Biosanitaria ibs.GRANADA, 18012 Granada, Spain;
- Department of Cell Biology, University of Granada (UGR), 18071 Granada, Spain
| | - María Correa-Rodríguez
- Instituto de Investigación Biosanitaria ibs.GRANADA, 18012 Granada, Spain;
- Department of Nursing, Faculty of Health Sciences, University of Granada (UGR), 18071 Granada, Spain
| | - María Encarnación Aguilar-Ferrándiz
- Department of Physical Therapy, Faculty of Health Sciences, University of Granada (UGR), 18071 Granada, Spain; (A.C.-B.); (F.M.); (R.M.T.-H.); (M.E.A.-F.)
- Instituto de Investigación Biosanitaria ibs.GRANADA, 18012 Granada, Spain;
| |
Collapse
|
2
|
Luo W, Cao L, Wang C. Low body temperature and mortality in critically ill patients with coronary heart disease: a retrospective analysis from MIMIC-IV database. Eur J Med Res 2023; 28:614. [PMID: 38124189 PMCID: PMC10731844 DOI: 10.1186/s40001-023-01584-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Accepted: 12/10/2023] [Indexed: 12/23/2023] Open
Abstract
BACKGROUND This study was aimed to investigate the correlation between low body temperature and outcomes in critically ill patients with coronary heart disease (CHD). METHODS Participants from the Medical Information Mart for Intensive Care (MIMIC)-IV were divided into three groups (≤ 36.5 ℃, 36.6-37.4 ℃, ≥ 37.5 ℃) in accordance with body temperature measured orally in ICU. In-hospital, 28-day and 90-day mortality were the major outcomes. Multivariable Cox regression, decision curve analysis (DCA), restricted cubic splines (RCS), Kaplan-Meier curves (with or without propensity score matching), and subgroup analyses were used to investigate the association between body temperature and outcomes. RESULTS A total of 8577 patients (65% men) were included. The in-hospital, 28-day, 90-day, and 1-year overall mortality rate were 10.9%, 16.7%, 21.5%, and 30.4%, respectively. Multivariable Cox proportional hazards regression analyses indicated that patients with hypothermia compared to the patients with normothermia were at higher risk of in-hospital [adjusted hazard ratios (HR) 1.23, 95% confidence interval (CI) 1.01-1.49], 28-day (1.38, 1.19-1.61), and 90-day (1.36, 1.19-1.56) overall mortality. For every 1 ℃ decrease in body temperature, adjusted survival rates were likely to eliminate 14.6% during the 1-year follow-up. The DCA suggested the applicability of the model 3 in clinical practice and the RCS revealed a consistent higher mortality in hypothermia group. CONCLUSIONS Low body temperature was associated with increased mortality in critically ill patients with coronary heart disease.
Collapse
Affiliation(s)
- Weiran Luo
- The Six Clinical Medical School, Capital Medical University, Beijing, China
| | - Lixue Cao
- Department of Medical Genetics and Developmental Biology, Capital Medical University School of Basic Medical Sciences, Beijing, China
| | - Chuan Wang
- Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Beijing, 100029, China.
| |
Collapse
|
3
|
Ravi N, Vithyananthan M, Saidu A. Are all thermometers equal? A study of three infrared thermometers to detect fever in an African outpatient clinic. PeerJ 2022; 10:e13283. [PMID: 35726256 PMCID: PMC9206434 DOI: 10.7717/peerj.13283] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Accepted: 03/25/2022] [Indexed: 01/13/2023] Open
Abstract
Infrared thermometry has certain advantages over traditional oral thermometry including quick, non-invasive administration and an absence of required consumables. This study compared the performance of tympanic, temporal artery and forehead contactless thermometers with traditional oral electronic thermometer as the reference in measuring temperature in outpatients in a Nigerian secondary care hospital. A convenience sample of 100 male and 100 female adult patients (Mean age = 38.46 years, SD = 16.33 years) were recruited from a secondary care hospital in Kano, Nigeria. Temperature measurements were taken from each patient using the tympanic, temporal artery and contactless thermometers and oral electronic thermometer. Data was analyzed to assess bias and limits using scatterplots and Bland-Altman charts while sensitivity analysis was done using ROC curves. The tympanic and temporal artery thermometers systematically gave higher temperature readings compared to the oral electronic thermometer. The contactless thermometer gave lower readings compared to the oral electronic thermometer. The temporal artery thermometer had the highest sensitivity (88%) and specificity (88%) among the three infrared thermometers. The contactless thermometer showed a low sensitivity of 13% to detect fever greater than 38 °C. Our study shows that replacing oral thermometers with infrared thermometers must be done with caution despite the associated convenience and cost savings.
Collapse
|
4
|
Cho MJ, Choi HI, Kim HJ, Bunsawat K, Kunutsor SK, Jae SY. Comparison of the acute effects of ankle bathing versus moderate-intensity aerobic exercise on vascular function in young adults. Appl Physiol Nutr Metab 2022; 47:469-481. [PMID: 35380875 DOI: 10.1139/apnm-2021-0272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
We examined the efficacy of ankle bathing versus aerobic exercise to improve vascular function in young adults who were randomized to aerobic exercise (AE) (n = 13, 40%-60% of heart rate reserve), ankle bathing (AB) (n = 15, 43 °C), or a control condition (CON) (n = 14, ankle bathing, 36 °C) for 40 min. Conduit vessel function [brachial artery flow-mediated dilation (FMD)], carotid and femoral artery blood flow and shear rate (SR), and arterial stiffness [carotid-to-femoral pulse wave velocity (cf-PWV), augmentation index (AIx@75), β-stiffness index, and arterial compliance] were evaluated. Compared with CON, AE and AB increased FMD at 30 min and 90 min (interaction: p < 0.05); AB decreased carotid artery blood flow and SR at 30 min, while both AE and AB increased femoral artery blood flow and SR at 30 min and 90 min (interaction: p < 0.05); AE and AB decreased cf-PWV and AIx@75 at 30 min and 90 min (interaction: p < 0.05); and AE improved both carotid and femoral β-stiffness index and arterial compliance, while AB reduced β-stiffness index and increased arterial compliance only in the femoral artery (interaction: p < 0.05). These findings suggest that ankle bathing may serve as an alternative strategy for enhancing vascular function. Novelty: We observed similar improvements in conduit vessel function, femoral artery blood flow and shear rate, and arterial stiffness following ankle bathing and acute aerobic exercise in young adults. These findings have identified ankle bathing as a potential therapeutic strategy for enhancing vascular function, which may be particularly relevant for those with limited ability to engage in regular aerobic exercise.
Collapse
Affiliation(s)
- Min Jeong Cho
- Department of Sport Science, University of Seoul, Seoul, Republic of Korea
| | - Ho Il Choi
- Department of Sport Science, University of Seoul, Seoul, Republic of Korea
| | - Hyun Jeong Kim
- Department of Sport Science, University of Seoul, Seoul, Republic of Korea
| | - Kanokwan Bunsawat
- Department of Internal Medicine, Division of Geriatrics, University of Utah, Salt Lake City, Utah, USA
| | - Setor K Kunutsor
- National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol, Bristol, UK.,Musculoskeletal Research Unit, Translational Health Sciences, Bristol Medical School, University of Bristol, Southmead Hospital, Bristol, UK
| | - Sae Young Jae
- Department of Sport Science, University of Seoul, Seoul, Republic of Korea.,Division of Urban Social Health, Graduate School of Urban Public Health, University of Seoul, Seoul, Republic of Korea
| |
Collapse
|
5
|
Masè M, Werner A, Putzer G, Avancini G, Falla M, Brugger H, Micarelli A, Strapazzon G. Low Ambient Temperature Exposition Impairs the Accuracy of a Non-invasive Heat-Flux Thermometer. Front Physiol 2022; 13:830059. [PMID: 35309078 PMCID: PMC8931521 DOI: 10.3389/fphys.2022.830059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 01/31/2022] [Indexed: 11/23/2022] Open
Abstract
Background Indirect core body temperature (CBT) monitoring from skin sensors is gaining attention for in-field applications thanks to non-invasivity, portability, and easy probe positioning. Among skin sensors, heat-flux devices, such as the so-called Double Sensor (DS), have demonstrated reliability under various experimental and clinical conditions. Still, their accuracy at low ambient temperatures is unknown. In this randomized cross-over trial, we tested the effects of cold temperature exposition on DS performance in tracking CBT. Methods Twenty-one participants were exposed to a warm (23.2 ± 0.4°C) and cold (−18.7 ± 1.0°C) room condition for 10 min, following a randomized cross-over design. The accuracy of the DS to estimate CBT in both settings was assessed by quantitative comparison with esophageal (reference) and tympanic (comparator) thermometers, using Bland–Altman and correlation analyses (Pearson’s correlation coefficient, r, and Lin’s concordance correlation coefficient, CCC). Results In the warm room setting, the DS showed a moderate agreement with the esophageal sensor [bias = 0.09 (−1.51; 1.69) °C, r = 0.40 (p = 0.069), CCC = 0.22 (−0.006; 0.43)] and tympanic sensor [bias = 2.74 (1.13; 4.35) °C, r = 0.54 (p < 0.05), CCC = 0.09 (0.008; 0.16)]. DS accuracy significantly deteriorated in the cold room setting, where DS temperature overestimated esophageal temperature [bias = 2.16 (−0.89; 5.22) °C, r = 0.02 (0.94), CCC = 0.002 (−0.05; 0.06)]. Previous exposition to the cold influenced temperature values measured by the DS in the warm room setting, where significant differences (p < 0.00001) in DS temperature were observed between randomization groups. Conclusion DS accuracy is influenced by environmental conditions and previous exposure to cold settings. These results suggest the present inadequacy of the DS device for in-field applications in low-temperature environments and advocate further technological advancements and proper sensor insulation to improve performance in these conditions.
Collapse
Affiliation(s)
- Michela Masè
- Institute of Mountain Emergency Medicine, Eurac Research, Bolzano, Italy
| | - Andreas Werner
- Institute of Physiology, Center for Space Medicine and Extreme Environments Berlin, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin, Germany
- German Air Force – Centre of Aerospace Medicine, Aviation Physiology Training Centre, Aviation Physiology Diagnostic and Research, Königsbrück, Germany
| | - Gabriel Putzer
- Department of Anaesthesiology and Intensive Care Medicine, Medical University of Innsbruck, Innsbruck, Austria
| | - Giovanni Avancini
- Department of Anaesthesia and Intensive Care, Santa Chiara Hospital, Trento, Italy
| | - Marika Falla
- Institute of Mountain Emergency Medicine, Eurac Research, Bolzano, Italy
- Centre for Mind/Brain Sciences, CIMeC, University of Trento, Rovereto, Italy
| | - Hermann Brugger
- Institute of Mountain Emergency Medicine, Eurac Research, Bolzano, Italy
- Department of Anaesthesiology and Intensive Care Medicine, Medical University of Innsbruck, Innsbruck, Austria
| | - Alessandro Micarelli
- Institute of Mountain Emergency Medicine, Eurac Research, Bolzano, Italy
- ITER Center for Balance and Rehabilitation Research (ICBRR), Rome, Italy
| | - Giacomo Strapazzon
- Institute of Mountain Emergency Medicine, Eurac Research, Bolzano, Italy
- Department of Anaesthesiology and Intensive Care Medicine, Medical University of Innsbruck, Innsbruck, Austria
- *Correspondence: Giacomo Strapazzon,
| |
Collapse
|
6
|
Nguyen LS, Helias M, Raia L, Nicolas E, Jaubert P, Benghanem S, Ait Hamou Z, Dupland P, Charpentier J, Pène F, Cariou A, Mira JP, Chiche JD, Jozwiak M. Impact of COVID-19 on the association between pulse oximetry and arterial oxygenation in patients with acute respiratory distress syndrome. Sci Rep 2022; 12:1462. [PMID: 35087122 PMCID: PMC8795352 DOI: 10.1038/s41598-021-02634-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Accepted: 11/15/2021] [Indexed: 01/08/2023] Open
Abstract
Managing patients with acute respiratory distress syndrome (ARDS) requires frequent changes in mechanical ventilator respiratory settings to optimize arterial oxygenation assessed by arterial oxygen partial pressure (PaO2) and saturation (SaO2). Pulse oxymetry (SpO2) has been suggested as a non-invasive surrogate for arterial oxygenation however its accuracy in COVID-19 patients is unknown. In this study, we aimed to investigate the influence of COVID-19 status on the association between SpO2 and arterial oxygenation. We prospectively included patients with ARDS and compared COVID-19 to non-COVID-19 patients, regarding SpO2 and concomitant arterial oxygenation (SaO2 and PaO2) measurements, and their association. Bias was defined as mean difference between SpO2 and SaO2 measurements. Occult hypoxemia was defined as a SpO2 ≥ 92% while concomitant SaO2 < 88%. Multiple linear regression models were built to account for confounders. We also assessed concordance between positive end-expiratory pressure (PEEP) trial-induced changes in SpO2 and in arterial oxygenation. We included 55 patients, among them 26 (47%) with COVID-19. Overall, SpO2 and SaO2 measurements were correlated (r = 0.70; p < 0.0001), however less so in COVID-19 than in non-COVID-19 patients (r = 0.55, p < 0.0001 vs. r = 0.84, p < 0.0001, p = 0.002 for intergroup comparison). Bias was + 1.1%, greater in COVID-19 than in non-COVID-19 patients (2.0 vs. 0.3%; p = 0.02). In multivariate analysis, bias was associated with COVID-19 status (unstandardized β = 1.77, 95%CI = 0.38–3.15, p = 0.01), ethnic group and ARDS severity. Occult hypoxemia occurred in 5.5% of measurements (7.7% in COVID-19 patients vs. 3.4% in non-COVID-19 patients, p = 0.42). Concordance rate between PEEP trial-induced changes in SpO2 and SaO2 was 84%, however less so in COVID-19 than in non-COVID-19 patients (69% vs. 97%, respectively). Similar results were observed for PaO2 regarding correlations, bias, and concordance with SpO2 changes. In patients with ARDS, SpO2 was associated with arterial oxygenation, but COVID-19 status significantly altered this association.
Collapse
Affiliation(s)
- Lee S Nguyen
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France.,Research and Innovation Department, CMC Ambroise Paré, Neuilly-sur-Seine, France
| | - Marion Helias
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France
| | - Lisa Raia
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France
| | - Estelle Nicolas
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France
| | - Paul Jaubert
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France
| | - Sarah Benghanem
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France.,Université de Paris, Paris, France
| | - Zakaria Ait Hamou
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France.,Université de Paris, Paris, France
| | - Pierre Dupland
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France.,Université de Paris, Paris, France
| | - Julien Charpentier
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France
| | - Frédéric Pène
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France.,Université de Paris, Paris, France
| | - Alain Cariou
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France.,Université de Paris, Paris, France
| | - Jean-Paul Mira
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France.,Université de Paris, Paris, France
| | - Jean-Daniel Chiche
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France.,Université de Paris, Paris, France
| | - Mathieu Jozwiak
- Hôpital Cochin, Service de Médecine Intensive Réanimation, Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris-Centre, 27 rue du faubourg Saint Jacques, 75014, Paris, France. .,Université de Paris, Paris, France. .,Equipe 2 CARRES, UR2CA - Unité de Recherche Clinique Côte d'Azur, Université Côte d'Azur UCA, Nice, France.
| |
Collapse
|
7
|
Sharif Nia H, Chong PP, Yiong Huak C, Gorgulu O, Taghipour B, Sivarajan Froelicher E, Pahlevan Sharif S, Rahmatpour P. Clinical accuracy and agreement between tympanic and forehead body temperature measurements for screening of patients with COVID-19. J Clin Nurs 2021; 31:3272-3285. [PMID: 34908206 DOI: 10.1111/jocn.16166] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Revised: 11/12/2021] [Accepted: 11/27/2021] [Indexed: 01/08/2023]
Abstract
AIM To investigate the accuracy, reliability and agreement between infrared forehead thermometers versus infrared tympanic thermometers temperature, a cross-sectional study was conducted in April 2020. METHODS The forehead and tympanic temperatures of 615 subjects were measured simultaneously in three exposed SARS-COV-2 groups at one hospital in Iran, during April 2020. These comparisons were evaluated by Bland-Altman Plot, repeatability, Passing-Bablok regression and Lin's concordance correlation coefficient. The receiver operating characteristic (ROC) analysis was done to describe the discrimination accuracy of a diagnostic test. The study adhered to STROBE checklist for cross-sectional studies. RESULTS A Bland-Altman plot indicated that the limits of agreement between the forehead and tympanic temperature were -0.259 to +0.19°C. Passing-Bablok regression analysis illustrated that the infrared forehead was not linearly related to tympanic temperatures (reference method), with a slope estimate that was significantly different from 1.00. The infrared forehead thermometer showed poor precision and lower accuracy than the tympanic. The forehead temperature readings had 60.0% sensitivity and 44.4% specificity (p > .05) to predict disease. CONCLUSION According to the results of study, there is no evidence that the assessment of temperature by infrared forehead thermometer could discriminate between the two groups (positive and negative).
Collapse
Affiliation(s)
- Hamid Sharif Nia
- School of Nursing and Midwifery Amol, Mazandaran University of Medical Sciences, Sari, Iran
| | - Pei Pei Chong
- School of Biosciences, Faculty of Health and Medical Sciences, Taylor's University, Subang Jaya, Malaysia
| | | | - Ozkan Gorgulu
- Kirsehir Ahi Evran University, Faculty of Medicine, Department of Biostatistics and Medical Information Kirsehir, Kirsehir, Turkey
| | - Behzad Taghipour
- Imam Khomeini' s Hospital of Amol, Mazandaran University of Medical Science, Sari, Iran
| | - Erika Sivarajan Froelicher
- Department of Physiological Nursing, School of Nursing and Department of Epidemiology & Biostatistics, School of Medicine, University of California San Francisco, San Francisco, California, USA
| | - Saeed Pahlevan Sharif
- Taylor's Business School, Taylor's University Lakeside Campus, Subang Jaya, Malaysia
| | - Pardis Rahmatpour
- Department of Nursing, Alborz University of Medical Sciences, Karaj, Iran
| |
Collapse
|
8
|
Tanaka S, Nakagawa K, Ozone Y, Kaneko Y, Sugiki S, Hoshino G, Saito S, Minami A, Tanaka H. Evaluation of the physiological changes in prehospital health-care providers influenced by environmental factors in the summer of 2020 during the COVID-19 pandemic. Acute Med Surg 2021; 8:e699. [PMID: 34745638 PMCID: PMC8552522 DOI: 10.1002/ams2.699] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/20/2021] [Accepted: 10/07/2021] [Indexed: 11/08/2022] Open
Abstract
Aim Wearing personal protective equipment (PPE) is essential to prevent infection transmission, but the risk of heatstroke increases with wearing PPE in a humid and hot environment. Therefore, we aimed to examine how environmental parameters change the body physiology in a hot environment during the coronavirus disease (COVID-19) pandemic. Methods This was a retrospective cohort study extracted from the MEDIC Japan heatstroke prevention database, which was recorded between 1 August and 7 September, 2020. Its database is a registry collection from seven healthy health-care providers. Subjects recorded their own vital signs (forehead and tympanic temperature, blood pressure, pulse rate, and oxygen saturation) and environmental factors (type of weather, wet-bulb globe temperature [WBGT], air temperature, humidity, and location) every hour during their working shift. Results From 323 records, a weak positive but statistically significant correlation was observed between WBGT and pulse rate (correlation coefficient [95% confidence interval], r = 0.34 [0.23, 0.45]) and between WBGT and core body temperature. Forehead temperature had a stronger correlation than tympanic temperature (forehead, r = 0.33 [0.21, 0.43]; tympanic, r = 0.17 [0.05, 0.28]), which also showed a larger effect (forehead, η2 = 0.08; tympanic, η2 = 0.05). The effect size of oxygen saturation measured outdoors was large (η2 = 0.30). Forehead temperature increased abruptly at 28°C WBGT and at 33°C air temperature. Conclusion A hot environment significantly affected forehead temperature, and the daytime imposed a high risk of heatstroke. To avoid heatstroke, environmental parameters are important to note as outdoor environments had a large effect on vital sign changes depending on the time of day.
Collapse
Affiliation(s)
- Shota Tanaka
- MEDIC Japan Inc. Shibuya Japan.,Research Institute of Disaster Management and EMS Kokushikan University Tama City Japan
| | - Koshi Nakagawa
- MEDIC Japan Inc. Shibuya Japan.,Graduate School of Emergency Medical System Kokushikan University Tama City Japan
| | - Yuki Ozone
- MEDIC Japan Inc. Shibuya Japan.,Sonoda Daiichi Hospital Adachi City Japan
| | - Yuuki Kaneko
- MEDIC Japan Inc. Shibuya Japan.,Faculty of Emergency Medical Science Meiji University of Integrative Medicine Nantan Japan
| | - Shota Sugiki
- MEDIC Japan Inc. Shibuya Japan.,Department of Emergency Medical Science Faculty of Health Sciences Kyoto Tachibana University Shibuya Japan
| | | | - Shunsuke Saito
- MEDIC Japan Inc. Shibuya Japan.,Graduate School of Emergency Medical System Kokushikan University Tama City Japan
| | | | - Hideharu Tanaka
- MEDIC Japan Inc. Shibuya Japan.,Research Institute of Disaster Management and EMS Kokushikan University Tama City Japan.,Graduate School of Emergency Medical System Kokushikan University Tama City Japan.,Department of Sports Medicine Kokushikan University Tama City Japan
| |
Collapse
|
9
|
Kiekkas P, Aretha D, Tzenalis A, Stefanopoulos N. Diagnostic accuracy of oral thermometry for fever detection in adult patients: literature review and meta-analysis. J Clin Nurs 2021; 31:520-531. [PMID: 34278635 DOI: 10.1111/jocn.15968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 05/05/2021] [Accepted: 06/02/2021] [Indexed: 11/30/2022]
Abstract
AIMS AND OBJECTIVES To synthesise the evidence on the accuracy and precision of oral thermometry in adult patients, as well as on its sensitivity and specificity for fever detection. BACKGROUND Oral thermometry has long been used in various clinical settings thanks to its rapid, safe and convenient measurements, which are easy to obtain and minimally prone to operator errors. DESIGN Literature review and meta-analysis that adhered to the PRISMA statement. METHODS By using key terms, literature searches were conducted in CINAHL, PubMed, Web of Science, Scopus and Cochrane Library. Method-comparison studies, which were published from January 1990 to December 2020 in English-language, peer-reviewed journals, compared oral temperature measurements with invasive thermometry ones, and were conducted on patients ≥18 years, were included. Methodological quality of selected studies was evaluated with QUADAS-2. RESULTS Sixteen articles were selected for inclusion. Risk of bias was assessed as low in most of them. Quantitative synthesis indicated that pooled mean oral temperature was lower than core temperature by .07℃, with 95% limits of agreement ranging between -.22℃ and .08℃. Pooled sensitivity and specificity for fever detection (defined as core temperature ≥38℃ in most studies) were .53 (95% confidence interval, .39-.66) and .98 (95% confidence interval, .97-.99), respectively. Sensitivity analysis indicated larger temperature underestimation in case rectal temperature was used as reference standard. CONCLUSION Despite its satisfactory accuracy, precision and specificity, oral thermometry has low sensitivity for fever detection, which entails a high number of false-negative readings and uncertainty for excluding fever in patients found to be non-febrile. RELEVANCE TO CLINICAL PRACTICE Oral thermometry cannot be recommended for replacing invasive thermometry methods in hospitalised adult patients, considering the high incidence of fever in them and possible negative effects of missing fever for patient diagnosis and outcomes.
Collapse
Affiliation(s)
| | - Diamanto Aretha
- Department of Anesthesiology and Critical Care Medicine, Patras University Hospital, Patras, Greece
| | | | | |
Collapse
|
10
|
Yoo JH, Ok SY, Kim SH, Chung JW, Park SY, Kim MG, Cho HB, Song SH, Choi YJ, Kim HJ, Oh HC. Comparison of upper and lower body forced air blanket to prevent perioperative hypothermia in patients who underwent spinal surgery in prone position: A randomized controlled trial. Korean J Anesthesiol 2021; 75:37-46. [PMID: 33984220 PMCID: PMC8831429 DOI: 10.4097/kja.21087] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Accepted: 05/09/2021] [Indexed: 11/23/2022] Open
Abstract
Background We compared upper- and lower-body forced-air blankets in terms of their ability to prevent perioperative hypothermia, defined as a reduction in body temperature to < 36.0°C, during the perioperative period in patients undergoing spine surgery in the prone position. Methods In total, 120 patients scheduled for elective spine surgery under general anesthesia were divided into an upper-warming group (n = 60) and a lower-warming group (n = 60). After inducing anesthesia and preparing the patient for surgery, including prone positioning, the upper and lower bodies of the patients in the upper- and lower-warming groups, respectively, were warmed using a forced-air warmer with specified upper and lower blankets. Body temperature was measured using a tympanic membrane thermometer during the pre- and post-operative periods and using a nasopharyngeal temperature probe during the intraoperative period. Patients were evaluated in terms of shivering, thermal comfort, and satisfaction in the post-anesthesia care unit (PACU). Results The incidence of intraoperative and postoperative hypothermia was lower in the upper-warming group than in the lower-warming group ([55.2% vs. 75.9%, P = 0.019] and [21.4% vs. 49.1%, P = 0.002]). Perioperative body temperature was higher in the upper-warming group (P < 0.001). However, intraoperative blood loss, postoperative thermal comfort scale and shivering scores, patient satisfaction, and PACU duration were similar in the two groups. Conclusions The upper-body blanket was more effective than the lower-body blanket for preventing perioperative hypothermia in patients who underwent spine surgery in the prone position.
Collapse
Affiliation(s)
- Jae Hwa Yoo
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University Hospital Seoul, Republic of Korea
| | - Si Young Ok
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University Hospital Seoul, Republic of Korea
| | - Sang Ho Kim
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University Hospital Seoul, Republic of Korea
| | - Ji Won Chung
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University Hospital Seoul, Republic of Korea
| | - Sun Young Park
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University Hospital Seoul, Republic of Korea
| | - Mun Gyu Kim
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University Hospital Seoul, Republic of Korea
| | - Ho Bum Cho
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University Hospital Seoul, Republic of Korea
| | - Sang Hoon Song
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University Hospital Seoul, Republic of Korea
| | - Yun Jeong Choi
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University Hospital Seoul, Republic of Korea
| | - Hyun Ju Kim
- Department of Anesthesiology and Pain Medicine, Soonchunhyang University Hospital Seoul, Republic of Korea
| | - Hong Chul Oh
- Department of Thoracic and Cardiovascular surgery, Soonchunhyang University Hospital Seoul, Republic of Korea
| |
Collapse
|
11
|
Casas-Barragán A, Molina F, Tapia-Haro RM, García-Ríos MC, Correa-Rodríguez M, Aguilar-Ferrándiz ME. Association of core body temperature and peripheral blood flow of the hands with pain intensity, pressure pain hypersensitivity, central sensitization, and fibromyalgia symptoms. Ther Adv Chronic Dis 2021; 12:2040622321997253. [PMID: 33747428 PMCID: PMC7940732 DOI: 10.1177/2040622321997253] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Accepted: 02/03/2021] [Indexed: 11/16/2022] Open
Abstract
Our aim was to analyse body core temperature and peripheral vascular microcirculation at skin hypothenar eminence of the hands and its relationship to symptoms in fibromyalgia syndrome (FMS). A total of 80 FMS women and 80 healthy women, matched on weight, were enrolled in this case-control study. Thermography and infrared thermometer were used for evaluating the hypothenar regions and core body temperature, respectively. The main outcome measures were pain pressure thresholds (PPTs) and clinical questionnaires. Significant associations were observed between overall impact [β = 0.033; 95% confidence interval (95%CI) = 0.003, 0.062; p = 0.030], daytime dysfunction (β = 0.203; 95%CI = 0.011, 0.395; p = 0.039) and reduced activity (β = 0.045; 95%CI = 0.005, 0.085; p = 0.029) and core body temperature in FMS women. PPTs including greater trochanter dominant (β = 0.254; 95%CI = 0.003, 0.504; p = 0.047), greater trochanter non-dominant (β = 0.650; 95%CI = 0.141, 1.159; p = 0.013), as well as sleeping medication (β = -0.242; 95%CI = -0.471, -0.013; p = 0.039) were also associated with hypothenar eminence temperature. Data highlighted that FMS women showed correlations among body core temperature and hand temperature with the clinical symptoms.
Collapse
Affiliation(s)
- Antonio Casas-Barragán
- Department of Physical Therapy, Faculty of Health Sciences, Instituto de Investigación Biosanitaria ibs.GRANADA, University of Granada, Granada, Spain
| | | | - Rosa María Tapia-Haro
- Department of Physical Therapy, Faculty of Health Sciences, Instituto de Investigación Biosanitaria ibs.GRANADA, University of Granada, Granada, Spain
| | - María Carmen García-Ríos
- Department of Physical Therapy, Faculty of Health Sciences, Instituto de Investigación Biosanitaria ibs.GRANADA, University of Granada, Granada, Spain
| | - María Correa-Rodríguez
- Department of Nursing, Faculty of Health Sciences, Instituto de Investigación Biosanitaria ibs. GRANADA, University of Granada, Ave. de la Ilustración, 60, Granada 18016, Spain
| | - María Encarnación Aguilar-Ferrándiz
- Department of Physical Therapy, Faculty of Health Sciences, Instituto de Investigación Biosanitaria ibs.GRANADA, University of Granada, Granada, Spain
| |
Collapse
|
12
|
Healy C, Segal Z, Hinnerichs C, Ace E, Ward D, Honovich J. Globally deployed COVID-19 fever screening devices using infrared thermographs consistently normalize high readings to afebrile range. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-200403SSRR. [PMID: 33715317 PMCID: PMC7955777 DOI: 10.1117/1.jbo.26.4.043009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 03/02/2021] [Indexed: 06/12/2023]
Abstract
SIGNIFICANCE The need for regulatory review of infrared thermographs (IRTs) used on humans was removed in response to the unique circumstances of the SARS-CoV-2 pandemic (a.k.a., COVID-19). The market for these devices has since expanded considerably. This evaluation of IRT performance may have significant implications for febrility screening worldwide. AIM Perform controlled nonhuman trials of IRT devices to identify and quantify deviations in the human temperature range. APPROACH We compared IRT readings of a temperature-controlled non-human subject with one FDA-cleared IRT and one FDA-cleared handheld NCIT. In individual trials for each device, the subject was measured between 35°C and 40°C at 0.25°C increments. RESULTS The IRT device measurements were consistently normalized around the human mean (∼37 ° C). Temperatures were decremented as they approached the febrile range, and systematically reported as normal across all seven devices. This effect does not appear to be explained by a fixed offset or any known approach to estimating body temperature, or by random error. CONCLUSION The IRTs in this study generated human temperature measurements that were systematically biased to the mean human temperature. Given that these devices are utilized for sentinel detection of possible infectious disease transmission, and are now globally employed, the implications for reduced detection of febrility are a widespread false sense of security. This vulnerability must be considered with respect to facility access control, clinical applications, and travel screening in the context of the ongoing COVID-19 pandemic response.
Collapse
Affiliation(s)
- Conor Healy
- IPVM, Bethlehem, Pennsylvania, United States
| | | | - Chris Hinnerichs
- Infrared Thermography for Febrile Screening in Public Health – ISBN-13: 978-3659263194
| | - Ethan Ace
- IPVM, Bethlehem, Pennsylvania, United States
| | - Derek Ward
- IPVM, Bethlehem, Pennsylvania, United States
| | | |
Collapse
|
13
|
Machin G, Brettle D, Fleming S, Nutbrown R, Simpson R, Stevens R, Tooley M. Is current body temperature measurement practice fit-for-purpose? J Med Eng Technol 2021; 45:136-144. [PMID: 33632055 DOI: 10.1080/03091902.2021.1873441] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
There has been a marked rise in the number of avoidable deaths in health services around the world. At the same time there has been a growing increase in antibiotic resistant so-called "superbugs." We examine here the potential role of body temperature measurement in these adverse trends. Electronic based thermometers have replaced traditional mercury (and other liquid-in-glass type) thermometers for reasons of safety rather than superiority. Electronic thermometers are in general less robust from a measurement perspective than their predecessors. We illustrate the implications of unreliable temperature measurement on the diagnosis and management of disease, including COVID-19, through statistical calculations. Since a return to mercury thermometers is both undesirable and impractical, we call for better governance in the current practice of clinical thermometry to ensure the traceability and long-term accuracy of electronic thermometers and discuss how this could be achieved.
Collapse
Affiliation(s)
| | - David Brettle
- Medical Physics, Leeds Teaching Hospitals NHS trust, Leeds, UK
| | - Susannah Fleming
- Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
| | - Rebecca Nutbrown
- Department of Medical Physics, Royal Surrey NHS Foundation Trust, Surrey, UK
| | - Rob Simpson
- National Physical Laboratory, Teddington, UK
| | - Richard Stevens
- Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
| | - Mark Tooley
- Office of the Chief Scientific Officer, Medical Directorate, London, UK
| |
Collapse
|
14
|
Aguilar-Ferrándiz ME, Casas-Barragán A, Tapia-Haro RM, Rus A, Molina F, Correa-Rodríguez M. Evaluation of sympathetic adrenergic branch of cutaneous neural control throughout thermography and its relationship to nitric oxide levels in patients with fibromyalgia. J Therm Biol 2020; 95:102813. [PMID: 33454042 DOI: 10.1016/j.jtherbio.2020.102813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 11/11/2020] [Accepted: 12/12/2020] [Indexed: 11/16/2022]
Abstract
BACKGROUND Fibromyalgia syndrome is defined as a complex disease, characterized by chronic widespread musculoskeletal pain and other symptoms. The factors underlying physiopathology of fibromyalgia are not well understood, complicating its diagnosis and management. OBJECTIVES To evaluate the peripheral vascular blood flow of the skin of the hands and the core body temperature as indirect measures of sympathetic adrenergic activity of the nervous system and its relationship to nitric oxide levels (NO) in women with fibromyalgia compared with healthy controls. METHODS Forty-two women with fibromyalgia and 52 healthy women were enrolled in this observational pilot study. We used infrared thermography of the hands and an infrared dermal thermometer to evaluate the peripheral vascular blood flow and tympanic and axillary core body temperature, respectively. We measured NO levels using the ozone chemiluminescence-based method. RESULTS Two-way analysis of covariance (ANCOVA) showed that the tympanic (P=0.002) and hand temperatures were significantly higher in the patients with fibromyalgia than in the controls (P≤0.001). Significant associations were also found between serum NO levels and minimum temperatures at the dorsal center of the dominant hand (β=-3.501; 95% confidence interval [CI] -6.805, ‑0.198; P= 0.038), maximum temperature (β=-5.594; 95% CI ‑10.106, ‑1.081; P=0.016), minimum temperature (β=-4.090; 95% CI ‑7.905, ‑0.275; P=0.036), and mean temperature (β=-5.519; 95% CI ‑9.933, ‑1.106; P=0.015) of the center of the palm of the non-dominant hand, maximum temperature at the thenar eminence of the dominant hand (β=-5.800; 95% CI ‑10.508, ‑1.092; P=0.017), and tympanic temperature (β=-9.321; 95% CI ‑17.974, ‑0.669; P=0.035) in the controls. CONCLUSIONS Our findings indicate that the women with fibromyalgia showed higher tympanic core body and hand temperature than the healthy controls. Moreover, there were negative associations between hand peripheral vasodilation and NO in the healthy women but not in those with fibromyalgia, suggesting a dysfunction of sympathetic cutaneous neural control.
Collapse
Affiliation(s)
- María Encarnación Aguilar-Ferrándiz
- Instituto de Investigación Biosanitaria ibs.GRANADA, Department of Physical Therapy, Faculty of Health Sciences, University of Granada (UGR), Spain.
| | - Antonio Casas-Barragán
- PhD Student of the Biomedicine Program of the University of Granada (UGR), Instituto de Investigación Biosanitaria ibs.GRANADA. Department of Physical Therapy, Faculty of Health Sciences, University of Granada (UGR), Spain.
| | - Rosa Maria Tapia-Haro
- Instituto de Investigación Biosanitaria ibs.GRANADA. Department of Physical Therapy, Faculty of Health Sciences, University of Granada (UGR), Spain.
| | - Alma Rus
- Instituto de Investigación Biosanitaria ibs.GRANADA. Department of Cell Biology, University of Granada (UGR), Spain.
| | - Francisco Molina
- Department of Health Sciences, Faculty of Health Sciences, University of Jaén, Spain.
| | - María Correa-Rodríguez
- Instituto de Investigación Biosanitaria ibs.GRANADA. Department of Nursing, Faculty of Health Sciences, University of Granada (UGR), Spain.
| |
Collapse
|
15
|
Warm-up durations in a hot-dry climate affect thermoregulation, mean power-output and fatigue, but not peak power in specific soccer repeated-sprint ability. BMC Sports Sci Med Rehabil 2020; 12:76. [PMID: 33298114 PMCID: PMC7724813 DOI: 10.1186/s13102-020-00221-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 11/10/2020] [Indexed: 11/19/2022]
Abstract
Background This study addressed the lack of data on the effect of warm-up (WU) duration in hot-dry climate (~ 30 °C; ~ 18% RH), on thermoregulation, muscular power-output, and fatigue after specific soccer repeated-sprint test (RSA). Methods Eleven amateur soccer players participated in a cross-over randomized study and they underwent the Bangsbo repeated-sprint test, after three WU durations (i.e. WU10, WU15 and WU20 min) at 70% of MAV, and on different days. Peak power (PP), mean power (MP) and the fatigue index (FI) were recorded and analyzed. Likewise, heart rate (HR), tympanic temperature (Ttym), mean body temperature (MBT) and rating of perceived exertion (RPE) were recorded during each session. Results The repeated measure ANOVA showed that MP improved after WU15 in comparison to WU10 and WU20 (p = 0.04 and p = 0.001; respectively). Nonetheless, no significant effect on PP was recorded after all WU durations. FI during RSA increased after WU20 in comparison to WU15 and WU10 (p < 0.001 and p = 0.003; respectively). Higher RPE values (p < 0.001) were recorded after WU15 and WU20 in comparison to WU10 duration. The two-way ANOVA showed higher ΔTtym and ΔMBT values after WU15 and WU20 compared to WU10 (p = 0.039 and p < 0.001for Ttym; p = 0.005 and p < 0.001 for MBT, respectively). Conclusions The WU15 at 70% of MAV better assists mean power-output during soccer RSA in hot-dry (~ 30 °C; 18% RH) climate, but not peak power. Reducing WU duration up to 10 min seems to be insufficient to induce beneficial physiological changes necessary for optimizing repeated-sprint performance, while its extension up to 20 min remains detrimental for muscular power and induces higher fatigue.
Collapse
|
16
|
Fienieg B, Hassing GJ, van der Wall HEC, van Westen GJP, Kemme MJB, Adiyaman A, Elvan A, Burggraaf J, Gal P. The association between body temperature and electrocardiographic parameters in normothermic healthy volunteers. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2020; 44:44-53. [PMID: 33179782 PMCID: PMC7894493 DOI: 10.1111/pace.14120] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Revised: 10/14/2020] [Accepted: 11/01/2020] [Indexed: 12/19/2022]
Abstract
Background Previous studies reported that hypo‐ and hyperthermia are associated with several atrial and ventricular electrocardiographical parameters, including corrected QT (QTc) interval. Enhanced characterization of variations in QTc interval and normothermic body temperature aids in better understanding the underlying mechanism behind drug induced QTc interval effects. The analysis’ objective was to investigate associations between body temperature and electrocardiographical parameters in normothermic healthy volunteers. Methods Data from 3023 volunteers collected at our center were retrospectively analyzed. Subjects were considered healthy after review of collected data by a physician, including a normal tympanic body temperature (35.5‐37.5°C) and in sinus rhythm. A linear multivariate model with body temperature as a continuous was performed. Another multivariate analysis was performed with only the QT subintervals as independent variables and body temperature as dependent variable. Results Mean age was 33.8 ± 17.5 years and mean body temperature was 36.6 ± 0.4°C. Body temperature was independently associated with age (standardized coefficient [SC] = −0.255, P < .001), female gender (SC = +0.209, P < .001), heart rate (SC = +0.231, P < .001), P‐wave axis (SC = −0.051, P < .001), J‐point elevation in lead V4 (SC = −0.121, P < .001), and QTcF duration (SC = −0.061, P = .002). In contrast, other atrial and atrioventricular (AV) nodal parameters were not independently associated with body temperature. QT subinterval analysis revealed that only QRS duration (SC = −0.121, P < .001) was independently associated with body temperature. Conclusion Body temperature in normothermic healthy volunteers was associated with heart rate, P‐wave axis, J‐point amplitude in lead V4, and ventricular conductivity, the latter primarily through prolongation of the QRS duration.
Collapse
Affiliation(s)
| | | | - Hein E C van der Wall
- Centre for Human Drug Research, Leiden, The Netherlands.,Leiden Academic Centre for Drug Research, Leiden, The Netherlands
| | | | - Michiel J B Kemme
- Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Ahmet Adiyaman
- Department of Cardiology, Isala Hospital, Zwolle, The Netherlands
| | - Arif Elvan
- Department of Cardiology, Isala Hospital, Zwolle, The Netherlands
| | - Jacobus Burggraaf
- Centre for Human Drug Research, Leiden, The Netherlands.,Leiden Academic Centre for Drug Research, Leiden, The Netherlands.,Leiden University Medical Center, Leiden, The Netherlands
| | - Pim Gal
- Centre for Human Drug Research, Leiden, The Netherlands.,Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
17
|
Aykanat VM, Broadbent E, Peyton PJ. Reliability of alternative devices for postoperative patient temperature measurement: two prospective, observational studies. Anaesthesia 2020; 76:514-519. [PMID: 32845016 DOI: 10.1111/anae.15248] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/31/2020] [Indexed: 11/28/2022]
Abstract
Peri-operative hypothermia is associated with significant morbidity, yet limitations exist regarding non-invasive temperature assessment in the post-anaesthesia care unit (PACU). In this prospective study of 100 patients, we aimed to determine the reliability of two commonly used temperature measurement devices, forehead temporal artery temperature and tympanic measurement, in addition to an indwelling urinary catheter with temperature probe, in comparison with the final nasopharyngeal core temperature at the end of surgery. Agreement of forehead measurement with nasopharyngeal temperature showed a mean bias (±95% limits of agreement) of 0.15 °C (±1.4 °C), with a steep slope of the relationship on the Bland-Altman plot of -0.8, indicating a tendency to normalise patient temperature readings to 36.4 °C. Only 54% of hypothermic cases were correctly detected by the forehead measurement device. Agreement of tympanic measurement with nasopharyngeal core temperature measurement was marginally improved with a mean bias of 0.13 °C (95% limits of agreement ±1.15 °C). In contrast, agreement of bladder temperature with nasopharyngeal temperature showed a mean (SD) bias of 0.19 (0.28) °C (95% limits of agreement ±0.54 °C), with a relatively flat line of best fit. We demonstrated that two commonly used temperature measurement devices, forehead temporal artery temperature and tympanic measurement, compared with nasopharyngeal core temperature, were imprecise and unreliable following major surgery. However, the indwelling catheter with temperature sensor was precise and acceptable for continuous core temperature measurement in the PACU.
Collapse
Affiliation(s)
- V M Aykanat
- Department of Anaesthesia, Austin Hospital, Melbourne, Victoria, Australia
| | - E Broadbent
- Austin Hospital, Melbourne, Victoria, Australia
| | - P J Peyton
- Department of Anaesthesia, Austin Hospital, Melbourne, Victoria, Australia
| |
Collapse
|
18
|
Chen HY, Chen A, Chen C. Investigation of the Impact of Infrared Sensors on Core Body Temperature Monitoring by Comparing Measurement Sites. SENSORS 2020; 20:s20102885. [PMID: 32438729 PMCID: PMC7284737 DOI: 10.3390/s20102885] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Revised: 05/13/2020] [Accepted: 05/19/2020] [Indexed: 01/24/2023]
Abstract
Many types of thermometers have been developed to measure body temperature. Infrared thermometers (IRT) are fast, convenient and ease to use. Two types of infrared thermometers are uses to measure body temperature: tympanic and forehead. With the spread of COVID-19 coronavirus, forehead temperature measurement is used widely to screen people for the illness. The performance of this type of device and the criteria for screening are worth studying. This study evaluated the performance of two types of tympanic infrared thermometers and an industrial infrared thermometer. The results showed that these infrared thermometers provide good precision. A fixed offset between tympanic and forehead temperature were found. The measurement values for wrist temperature show significant offsets with the tympanic temperature and cannot be used to screen fevers. The standard operating procedure (SOP) for the measurement of body temperature using an infrared thermometer was proposed. The suggestion threshold for the forehead temperature is 36 °C for screening of fever. The body temperature of a person who is possibly ill is then measured using a tympanic infrared thermometer for the purpose of a double check.
Collapse
Affiliation(s)
- Hsuan-Yu Chen
- Department of Materials Science and Engineering, University of California, San Diego, CA 92093, USA;
| | - Andrew Chen
- Africa Research Center, National Chung Hsing University, Taichung 40227, Taiwan;
| | - Chiachung Chen
- Department of Bio-industrial Mechatronics Engineering, National ChungHsing University, Taichung 40227, Taiwan
- Correspondence: ; Tel.: +886-4-22857562
| |
Collapse
|
19
|
Non-Invasive Forehead Segmentation in Thermographic Imaging. SENSORS 2019; 19:s19194096. [PMID: 31546740 PMCID: PMC6806055 DOI: 10.3390/s19194096] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 09/19/2019] [Accepted: 09/20/2019] [Indexed: 02/06/2023]
Abstract
The temperature of the forehead is known to be highly correlated with the internal body temperature. This area is widely used in thermal comfort systems, lie-detection systems, etc. However, there is a lack of tools to achieve the segmentation of the forehead using thermographic images and non-intrusive methods. In fact, this is usually segmented manually. This work proposes a simple and novel method to segment the forehead region and to extract the average temperature from this area solving this lack of non-user interaction tools. Our method is invariant to the position of the face, and other different morphologies even with the presence of external objects. The results provide an accuracy of 90% compared to the manual segmentation using the coefficient of Jaccard as a metric of similitude. Moreover, due to the simplicity of the proposed method, it can work with real-time constraints at 83 frames per second in embedded systems with low computational resources. Finally, a new dataset of thermal face images is presented, which includes some features which are difficult to find in other sets, such as glasses, beards, moustaches, breathing masks, and different neck rotations and flexions.
Collapse
|
20
|
Development of a Wireless Health Monitoring System for Measuring Core Body Temperature from the Back of the Body. JOURNAL OF HEALTHCARE ENGINEERING 2019; 2019:8936121. [PMID: 30911365 PMCID: PMC6397989 DOI: 10.1155/2019/8936121] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/16/2018] [Revised: 11/26/2018] [Accepted: 12/27/2018] [Indexed: 11/17/2022]
Abstract
In this paper, a user-friendly and low-cost wireless health monitoring system that measures skin temperature from the back of the body for monitoring the core body temperature is proposed. To measure skin temperature accurately, a semiconductor-based microtemperature sensor with a maximum accuracy of ±0.3°C was chosen and controlled by a high-performance/low-power consumption Acorn-Reduced Instruction Set Computing Machine (ARM) architecture microcontroller to build the temperature measuring device. Relying on a 2.4 GHz multichannel Gaussian frequency shift keying (GFSK) RF communication technology, up to 100 proposed temperature measuring devices can transmit the data to one receiver at the same time. The shell of the proposed wireless temperature-measuring device was manufactured via a 3D printer, and the device was assembled to conduct the performance tests and in vivo experiments. The performance test was conducted with a K-type temperature sensor in a temperature chamber to observe temperature measurement performance. The results showed an error value between two devices was less than 0.1°C from 25 to 40°C. For the in vivo experiments, the device was attached on the back of 10 younger male subjects to measure skin temperature to investigate the relationship with ear temperature. According to the experimental results, an algorithm based on the curve-fitting method was implemented in the proposed device to estimate the core body temperature by the measured skin temperature value. The algorithm was established as a linear model and set as a quadratic formula with an interpolant and with each coefficient for the equation set with 95% confidence bounds. For evaluating the goodness of fit, the sum of squares due to error (SSE), R-square, adjusted R-square, and root mean square error (RMSE) values were 33.0874, 0.0212, 0.0117, and 0.3998, respectively. As the experimental results have shown, the mean value for an error between ear temperature and estimated core body temperature is about ±0.19°C, and the mean bias is 0.05 ± 0.14°C when the subjects are in steady status.
Collapse
|
21
|
Nutong R, Mungthin M, Hatthachote P, Ukritchon S, Imjaijit W, Tengtrakulcharoen P, Panichkul S, Putwatana P, Prapaipanich W, Rangsin R. Personal risk factors associated with heat-related illness among new conscripts undergoing basic training in Thailand. PLoS One 2018; 13:e0203428. [PMID: 30180213 PMCID: PMC6122829 DOI: 10.1371/journal.pone.0203428] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2016] [Accepted: 08/21/2018] [Indexed: 12/03/2022] Open
Abstract
Cases of exertional heat stroke have been reported every year during basic training for Royal Thai Army (RTA) conscripts. Prevention is an important strategy to reduce the incidence of heat-related illnesses. We conducted a study to identify potential indicators for the prevention and monitoring of heat-related illnesses among military conscripts undergoing basic training in Thailand. All newly inducted RTA conscripts in 5 basic training units in 5 regions in Thailand were invited to participate in a prospective cohort study from May 1 to July 9, 2013. The incidence rate of heat-related illnesses and the incidence rate ratio (IRR) based on a Poisson regression model were used to identify the independent factors associated with heat-related illnesses, daily tympanic (body) temperatures higher than 37.5°C, >3% decreases in body weight in one day, and the production of dark brown urine. Eight hundred and nine men aged 21.4 (±1.13) years were enrolled in this study. The prevalence of a body mass index (BMI) ≥30 kg/m2 was 5.5%. During the study period, 53 subjects (6.6%) representing 3.41/100 person-months (95% confidence interval (CI), 2.55–4.23) developed heat-related illnesses (excluding heat rash), and no subjects experienced heat stroke. The incidence rates of a daily tympanic temperature >37.5°C at least once, body weight loss of >3% per day, and the production of dark brown urine at least once were 8.27/100 person-months (95% CI, 7.69–8.93), 47.91/100 person-months (95% CI, 44.22–51.58), and 682.11/100 person-months (95% CI, 635.49–728.52), respectively. The sole identified independent factor related to the incidence of heat-related illnesses was a BMI ≥30 kg/m2 (adjusted IRR = 2.66, 95% CI, 1.01–7.03). In conclusion, a high BMI was associated with heat-related illnesses among conscripts undergoing basic training in Thailand. Daily monitoring of heat-related illnesses, body temperature, body weight and urine color in each new conscript during basic military training was feasible.
Collapse
Affiliation(s)
- Rudchanu Nutong
- Ramathibodi School of Nursing, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Mathirut Mungthin
- Department of Pharmacology, Phramongkutklao College of Medicine, Bangkok, Thailand
| | - Panadda Hatthachote
- Department of Physiology, Phramongkutklao College of Medicine, Bangkok, Thailand
| | - Supak Ukritchon
- Office of Research and Development, Phramongkutklao College of Medicine, Bangkok, Thailand
| | - Worarachanee Imjaijit
- Office of Research and Development, Phramongkutklao College of Medicine, Bangkok, Thailand
| | | | - Suthee Panichkul
- Department of Military and Community Medicine, Phramongkutklao College of Medicine, Bangkok, Thailand
| | - Panwadee Putwatana
- Ramathibodi School of Nursing, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Wonnapha Prapaipanich
- Ramathibodi School of Nursing, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Ram Rangsin
- Department of Military and Community Medicine, Phramongkutklao College of Medicine, Bangkok, Thailand
- * E-mail:
| |
Collapse
|
22
|
Kollmann Camaiora A, Brogly N, Alsina E, de Celis I, Huercio I, Gilsanz F. Validation of the Zero-Heat-Flux thermometer (SpotOn®) in major gynecological surgery to monitor intraoperative core temperature: a comparative study with esophageal core temperature. Minerva Anestesiol 2018; 85:351-357. [PMID: 29945430 DOI: 10.23736/s0375-9393.18.12188-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
BACKGROUND The Zero-Heat-Flux technology of the SpotOn® sensor to measure core temperature has been validated in vascular and cardiac surgery. Our aim was to assess its validity in gynecological surgery in terms of time of measurement, thermic status (hypo-, normo-, or hyperthermia) and the use of different warming devices. METHODS Prospective study in patients scheduled for major gynecological surgery using three warming systems (Snuggle Warm®, Lithotomy Underbody Blanket® and Warmtac Pad®). Intraoperative temperature was simultaneously monitored using the SpotOn® sensor and a Dräger® esophageal probe; measurements were taken after induction (T0), between 0 and 60 min (T1), between 60 and 120 minutes (T2) and after 120 minutes (T3). We calculated the level of correlation between pairs of measurements both overall and in subgroups with an acceptable difference of less than 0.5 °C. We built Bland-Altman plots, and calculated the Pearson correlation (PC) and intraclass correlation coefficient (ICC) to test our data. RESULTS We recruited 70 patients and included 66 for analysis, giving a total of 401 paired measurements. Overall, the PC and ICC for paired temperature readings were 0.82 and 0.90, respectively. The lowest levels of correlation were observed after intubation, when a convective blanket was placed under the patient, and in hypothermic patients. The highest correlations were observed at T2, and in normothermic patients. CONCLUSIONS We found a high overall correlation between the SpotOn® and the esophageal probe, with negligible differences and almost perfect agreement. The warming system used, time of measurement, and thermic status appear to influence the level of correlation, but these differences were not clinically significant.
Collapse
Affiliation(s)
| | - Nicolas Brogly
- Department of Anesthesia and Intensive Care, La Paz University Hospital, Madrid, Spain
| | - Estibaliz Alsina
- Department of Anesthesia and Intensive Care, La Paz University Hospital, Madrid, Spain
| | - Isabel de Celis
- Department of Anesthesia and Intensive Care, La Paz University Hospital, Madrid, Spain
| | - Ivan Huercio
- Department of Anesthesia and Intensive Care, La Paz University Hospital, Madrid, Spain
| | - Fernando Gilsanz
- Department of Anesthesia and Intensive Care, La Paz University Hospital, Madrid, Spain
| |
Collapse
|