Shuai T, Shao T, Yi L, Han S, Jiménez-Herrera MF, Wang Z, Li X. The effect of different types of water sources on dental unit waterline contamination: A systematic review and meta analysis. Heliyon 2024; 10:e35745. [PMID: 39220891 PMCID: PMC11365326 DOI: 10.1016/j.heliyon.2024.e35745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 07/28/2024] [Accepted: 08/02/2024] [Indexed: 09/04/2024] Open
Abstract
To systematically review the effect of different types of water sources on dental unit waterline (DUWL) contamination. 5 databases were searched from their inception to December 23, 2023. Two reviewers independently extracted the data and assessed the quality of the literature. The risk ratio (RR) was used as measure of effect size in meta-analysis. The Grading of Recommendations, Assessment, Development and Evaluation (GRADE) was used for evaluating quality of the evidence. Meta-analysis was completed by RevMan 5.4.5 studies involving 561 water samples were quantified for meta-analysis. The results indicated that no significant differences were found in view of contamination rate (RR = 1.01; 95 % CI, 0.72-1.41; P = 0.96, I 2 = 62 %; GRADE low)and detection rate of Pseudomonas aeruginosa (RR = 0.78; 95 % CI, 0.15-4.13; P = 0.77; I 2 = 83 %; GRADE very low) between using purified water and tap water as water sources of DUWL. The available evidence suggests that there is no significant difference between purified water and tap water in controlling DUWL contamination. However, the conclusions need to be further validated through more randomized controlled trials with robust design and a large sample size.
Collapse
Affiliation(s)
- Ting Shuai
- Second Clinical Division, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing, 100081, China
| | - Tianyi Shao
- School of Nursing, Peking University, Beijing, 100191, China
| | - Lijuan Yi
- Department of Nursing, Hunan Traditional Chinese Medical College, Zhuzhou, 412000, China
- Nursing Department, Universitat Rovira i Virgili, Tarragona, Spain
| | - Shuyu Han
- School of Nursing, Peking University, Beijing, 100191, China
| | | | - Zhiwen Wang
- School of Nursing, Peking University, Beijing, 100191, China
| | - Xiue Li
- Department of Nursing, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing, 100081, China
| |
Collapse
|
2
|
Baudet A, Lizon J, Florentin A, Mortier É. Initial waterline contamination by Pseudomonas aeruginosa in newly installed dental chairs. Microbiol Spectr 2024; 12:e0396223. [PMID: 38652098 PMCID: PMC11237434 DOI: 10.1128/spectrum.03962-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 04/08/2024] [Indexed: 04/25/2024] Open
Abstract
Water contamination in dental unit waterlines (DUWLs) is a potential source of healthcare-associated infection during dental care. The aim of this study was to evaluate the microbiological quality of DUWLs water from newly installed dental chairs in a French University Hospital. The microbiological quality of water from 24 new DUWLs initially disinfected by ICX Renew-prior to use of the dental units for patient treatment-was assessed for total culturable aerobic bacteria at 22°C and 36°C, Legionella sp., Pseudomonas aeruginosa, and total coliforms. Among the 24 samples analyzed, 21 were compliant with the water quality levels: 19 had no bacteria, and 2 contained only 4 and 1 CFU/mL for total culturable aerobic bacteria at 22°C and 36°C, respectively. Three samples were non-compliant due to contamination by P. aeruginosa (4, 2, and 2 CFU/100 mL). Controlling and preventing the microbiological contamination of DUWLs, especially by pathogenic bacteria, at the time of the installation of the new dental chairs are crucial to prevent healthcare-associated infection in dentistry. IMPORTANCE Dental unit waterlines (DUWLs) of new dental chairs may be contaminated before their first clinical use, so an initial shock disinfection is crucial at the time of their installation. The microbiological analyses are crucial to control the water quality of DUWLs before their first clinical use because their disinfection does not guarantee the elimination of all bacteria.
Collapse
Affiliation(s)
- Alexandre Baudet
- Faculté d’odontologie, Université de Lorraine, Nancy, France
- CHRU-Nancy, Service d’odontologie, Nancy, France
- Université de Lorraine, Inserm, INSPIIRE, Nancy, France
| | - Julie Lizon
- Département territorial d’hygiène et prévention du risque infectieux (DTPRI), CHRU-Nancy, Nancy, France
| | - Arnaud Florentin
- Université de Lorraine, Inserm, INSPIIRE, Nancy, France
- Département territorial d’hygiène et prévention du risque infectieux (DTPRI), CHRU-Nancy, Nancy, France
- Département d’hygiène, des risques environnementaux et associés aux soins (DHREAS), Faculté de Médecine, Université de Lorraine, Nancy, France
| | - Éric Mortier
- Faculté d’odontologie, Université de Lorraine, Nancy, France
- CHRU-Nancy, Service d’odontologie, Nancy, France
- CNRS, IJL, Université de Lorraine, Nancy, France
| |
Collapse
|
3
|
Chen P, Zeng J, Hong F, Li C, Wang H, Yu X. The importance of biofilm contamination control for dental unit waterlines: a multicenter assessment of the microbiota diversity of biofilm in dental unit waterlines. J Oral Microbiol 2023; 16:2299496. [PMID: 38174123 PMCID: PMC10763872 DOI: 10.1080/20002297.2023.2299496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 12/21/2023] [Indexed: 01/05/2024] Open
Abstract
Background The biofilm formation in Dental Unit Waterlines (DUWLs) could become an important cause of infection during dental care, which could put immunocompromised individuals at risk of cross-infection. The aim of this study was to characterize the microbial communities of biofilms among DUWLs using high-throughput sequencing technology. Methods Twenty-nine biofilm samples were obtained from 24 dental chair units at 5 hospitals and 2 dental clinics. The genomic DNA of the samples was extracted, then 16S rDNA and ITS2 gene were amplified and sequenced. Alpha-diversity and Beta-diversity were calculated with QIIME2 and the Kruskal - Wallis H-test was adopted for statistical analysis. Results Microbial communities with a high diversity of bacteria (377 genera) and fungi (83 genera) were detected in the biofilm samples. The dominant phylum of bacteria was Proteobacteria (93.27%) and that of fungi was Basidiomycota (68.15%). Potential human pathogens were detected including 7 genera of bacteria (Pseudomonas, Stenotrophomonas, Hafnia-Obesumbacterium, Burkholderia-Caballeronia-Paraburkholderia, Ralstonia, Enterobacter, Klebsiella) and 6 genera of fungi (Malassezia, Candida, Alternaria, Cryptococcus, Rhodotorula, Rhinocladiella). Conclusions This multicenter assessment revealed the infectious risk during dental care. It emphasized the importance of biofilm control due to biofilm accumulation and multiple kinds of opportunistic pathogens in DUWLs.
Collapse
Affiliation(s)
- Piaopiao Chen
- Key Laboratory of Oral Biomedical Research of Zhejiang Province, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Jiang Zeng
- Key Laboratory of Oral Biomedical Research of Zhejiang Province, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Feiruo Hong
- Stomatology Hospital, School of Stomatology, Zhejiang, University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, ZhejiangChina
| | - Cong Li
- Stomatology Hospital, School of Stomatology, Zhejiang, University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, ZhejiangChina
| | - Huimin Wang
- School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China
| | - Xuefen Yu
- Stomatology Hospital, School of Stomatology, Zhejiang, University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, ZhejiangChina
| |
Collapse
|
4
|
Krishnan CS, Tompkins GR, Lyons KM, Cannon RD. Electrolysed oxidising water as a multi-purpose biocide in dental healthcare-A scoping review. Gerodontology 2023; 40:422-462. [PMID: 37694292 DOI: 10.1111/ger.12712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/20/2023] [Indexed: 09/12/2023]
Abstract
OBJECTIVES The objective of this scoping review was to map evidence of electrolysed oxidising water (EOW) as a biocide for dental applications of relevance to older people and identify research gaps. BACKGROUND EOW is an emerging, "green," and cost-effective biocide. There are no reviews on the landscape of EOW research as either an antiseptic or disinfectant in dental healthcare or its suitability for the oral healthcare of older people. MATERIALS AND METHODS The review follows the PRISMA Extension for Scoping Reviews (PRISMA-ScR) guidelines. Database searches (Google Scholar, PubMed, Web of Science, Ovid, Scopus and Science Direct) were undertaken using MESH terms and Boolean operators with no date restrictions, to identify full-text, original reports published in English-language peer-reviewed journals. RESULTS The search yielded 114 papers that met the inclusion/exclusion criteria. Dental applications of EOW include its use as an endodontic irrigant (39%); mouth rinse/surgical irrigant (21%); disinfectant for dental unit water lines (19%) and dental biomaterials (17%); and for antimicrobial efficacy, effects on oral tissues and on dental material properties. Most studies (83%) evaluated a single EOW formulation (acidic, moderately acidic or neutral) that was either generated at 'point-of-use' (POU; 72%), bottled ('ready-to-use', RTU; 24%) or from unspecified (3%) sources. Six reports evaluated storage-related parameters and 25 evaluated clinical applications; 89 were in vitro studies and one investigated the cost-effectiveness of POU EOW. CONCLUSIONS Neutral-pH, EOW is effective as an antimicrobial agent without deleterious effects on oral tissues. However, research on the impact of storage conditions, anti-Candida biofilm efficacy and mechanism of action against yeasts, long-term effects on denture materials and cost-effectiveness is required to establish the suitability of EOW as a multipurpose biocide for dental healthcare, including infection-control requirements relating to older people.
Collapse
Affiliation(s)
- Chitra S Krishnan
- Department of Oral Sciences, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Geoffrey R Tompkins
- Department of Oral Sciences, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Karl M Lyons
- Department of Oral Rehabilitation, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Richard D Cannon
- Department of Oral Sciences, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| |
Collapse
|
5
|
Hoogenkamp MA, Mazurel D, Deutekom-Mulder E, de Soet JJ. The consistent application of hydrogen peroxide controls biofilm growth and removes Vermamoeba vermiformis from multi-kingdom in-vitro dental unit water biofilms. Biofilm 2023; 5:100132. [PMID: 37346320 PMCID: PMC10279787 DOI: 10.1016/j.bioflm.2023.100132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 05/24/2023] [Accepted: 05/24/2023] [Indexed: 06/23/2023] Open
Abstract
The water systems inside a dental unit are known to be contaminated with a multi-kingdom biofilm encompassing bacteria, fungi, viruses and protozoa. Aerosolization of these micro-organisms can potentially create a health hazard for both dental staff and the patient. Very little is known on the efficacy of dental unit disinfection products against amoeba. In this study we have examined the effect of four different treatment regimens, with the hydrogen peroxide (H2O2) containing product Oxygenal, on an in-vitro multi-kingdom dental unit water system (DUWS) biofilm. The treatment efficacy was assessed in time using heterotrophic plate counts, the bacterial 16S rDNA, fungal 18S rDNA gene load and the number of genomic units for Legionella spp. the amoeba Vermamoeba vermiformis. The results indicated that a daily treatment of the DUWS with a low dose H2O2 (0.02% for 5 h), combined with a weekly shock dose (0.25% H2O2, 30 min) is necessary to reduce the heterotrophic plate count of a severely contaminated DUWS (>106 CFU.mL-1) to below 100 CFU.mL-1. A daily treatment with a low dose hydrogen peroxide alone, is sufficient for the statistically significant reduction of the total amount of bacterial 16S rDNA gene, Legionella spp. and Vermamoeba vermiformis load (p < 0.005). Also shown is that even though hydrogen peroxide does not kill the trophozoite nor the cysts of V. vermiformis, it does however result in the detachment of the trophozoite form of this amoeba from the DUWS biofilm and hereby ultimately removing the amoeba from the system.
Collapse
Affiliation(s)
- Michel A. Hoogenkamp
- Corresponding author. Gustav Mahlerlaan 3004, 1081 LA, Amsterdam, the Netherlands.
| | | | | | | |
Collapse
|
6
|
Buitrago JM, Kolbe RJ, Siqueira MF. Dental unit waterline testing practices: an 11-Year retrospective study. BMC Oral Health 2023; 23:867. [PMID: 37968643 PMCID: PMC10652605 DOI: 10.1186/s12903-023-03590-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 10/27/2023] [Indexed: 11/17/2023] Open
Abstract
OBJECTIVES This retrospective study examined the dental unit waterline (DUWL) testing practices of Saskatchewan dental clinics over a period of 11 years, with an emphasis on their responses after identification of high microbial levels. MATERIALS AND METHODS Dental clinics (n = 137) aseptically collected samples of output water from their air/water syringes, handpieces, and ultrasonic scaler lines using Sigma-Aldrich® waterline test kits and delivered them to a quality assurance laboratory. Tests were incubated for seven days at room temperature, and those with heterotrophic plate counts > 500 CFU/mL were reported as failures. Statistical analyses were performed on a database containing 4,093 test results. RESULTS Participating clinics submitted an average of 11 DUWL tests per year. Overall, 21% of tests failed, and a moderate positive association (rs=.52, p < 0.001) was found between clinics' DUWL testing frequency and failure rate. Only 7% of failed DUWL tests were followed up by collection of a subsequent test within two weeks, of which 47% still exceeded the 500 CFU/mL threshold. CONCLUSIONS Our findings demonstrate an association between DUWL testing frequency and detection of unacceptable microbial levels, along with infrequent retesting and often-inadequate intervention after a failed test. This suggests the need for further efforts at the regulatory and educational levels to maintain adequate water quality during dental treatment. CLINICAL RELEVANCE Procedural water can become contaminated in DUWLs and endanger patients. Regular DUWL monitoring and evidence-based interventions to treat contaminated systems are necessary to safeguard patient health.
Collapse
Affiliation(s)
- Juan M Buitrago
- College of Dentistry, University of Saskatchewan, Saskatoon, SK, Canada
| | - Rob J Kolbe
- College of Dentistry, University of Saskatchewan, Saskatoon, SK, Canada
| | | |
Collapse
|
7
|
Patil R, Hindlekar A, Jadhav GR, Mittal P, Humnabad V, Di Blasio M, Cicciù M, Minervini G. Comparative evaluation of effect of sodium hypochlorite and chlorhexidine in dental unit waterline on aerosolized bacteria generated during dental treatment. BMC Oral Health 2023; 23:865. [PMID: 37964280 PMCID: PMC10647182 DOI: 10.1186/s12903-023-03585-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Accepted: 10/27/2023] [Indexed: 11/16/2023] Open
Abstract
BACKGROUND In dentistry, nosocomial infection poses a great challenge to clinicians. The microbial contamination of water in dental unit waterlines (DUWLs) is ubiquitous. Such infected DUWLs can transmit oral microbes in the form of aerosols. Previous studies have suggested treating DUWLs with various disinfectants to reduce cross-contamination. The literature lacks a comparative evaluation of the effect of the use of 0.2% chlorhexidine (CHX) and 0.1% sodium hypochlorite (NaOCl) in DUWLs on aerosolized bacteria generated during dental procedures. OBJECTIVE To compare the effect of NaOCl and CHX in DUWLs on aerosolized bacteria generated during restorative and endodontic procedures. MATERIALS AND METHODS A total of 132 patients were equally divided into three groups (n = 44 in each group) according to the content of DUWL as follows. Group I-0.1% NaOCl Group II-0.2% CHX Group III-distilled water (Positive control) One-way ANOVA was performed and the Kruskal-Wallis test was used for intergroup comparison. RESULTS For the restorative procedure, inter-group comparison of mean colony-forming units (CFU) scores showed a statistically significant difference between the groups (p - .001) with the score of group 3 higher than group 2 followed by group 1. For the endodontics, an inter-group comparison of CFU scores showed a statistically significant difference between the groups (p - .003) with the mean score in group 1 being the lowest and group 3 being the highest. CONCLUSION The addition of NaOCl or CHX in DUWLs shows an effective reduction in aerosolized bacteria compared to distilled water.
Collapse
Affiliation(s)
- Rutuja Patil
- Department of Conservative Dentistry and Endodontics, Dr D. Y. Patil Dental College & Hospital, Dr. D. Y. Patil Vidyapeeth, Pimpri, Pune -18, India
| | - Ajit Hindlekar
- Department of Conservative Dentistry and Endodontics, Dr D. Y. Patil Dental College & Hospital, Dr. D. Y. Patil Vidyapeeth, Pimpri, Pune -18, India
| | | | - Priya Mittal
- Department of Conservative Dentistry and Endodontics, Swargiya Dadasaheb Kalmegh Smruti Dental College & Hospital, Nagpur, India
| | - Vamshi Humnabad
- Department of Conservative Dentistry and Endodontics, Dr D. Y. Patil Dental College & Hospital, Dr. D. Y. Patil Vidyapeeth, Pimpri, Pune -18, India
| | - Marco Di Blasio
- Department of Medicine and Surgery, University Center of Dentistry, University of Parma, 43126, Parma, Italy.
| | - Marco Cicciù
- Department of Biomedical and Surgical and Biomedical Sciences, Catania University, 95123, Catania, Italy
| | - Giuseppe Minervini
- Saveetha Dental College & Hospitals, Saveetha Institute of Medical & Technical Sciences Saveetha University, Chennai, India.
- Multidisciplinary Department of Medical-Surgical and Odontostomatological Specialties, University of Campania "Luigi Vanvitelli", Naples, Italy.
| |
Collapse
|
8
|
Petchphayaprai C, Chotipan C, Sa-Ngiampak P, Thotsaporn K, Ampornaramveth RS. Effectiveness of iodine for continuous decontamination of dental unit waterline. BDJ Open 2023; 9:34. [PMID: 37481614 PMCID: PMC10363156 DOI: 10.1038/s41405-023-00160-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 06/19/2023] [Accepted: 07/03/2023] [Indexed: 07/24/2023] Open
Abstract
OBJECTIVE Dental Unit Waterlines (DUWLs) are contaminated by various species of microorganisms. DUWLs should be disinfected appropriately to control microbial contamination. This study investigated the effectiveness of devices continuously releasing iodine to control microbial contamination in DUWLs. MATERIALS AND METHODS Ten dental chair units (DCU) at Chulalongkorn University were randomized into the iodine and control groups. After setting iodine treatment devices, the DCU was allowed to operate normally. 25 ml of water from airotors lines were collected weekly for enumerating bacteria. The viability of biofilms in DUWLs was quantified by ATP testing kit. The amount of iodine released into the procedural water was also quantified. RESULTS The continuous presence of iodine could significantly control bacterial contamination in the DUWL to be less than 500 CFU/mL, the standard level recommended by the Centre for Disease Control and Prevention (CDC). Iodine treatment can reduce bacterial CFU up to 98-100%. Biofilm viability in the iodine group was slightly lower than that of the control group though not statistically significant. After eleven months, the average iodine release was measured to be 3.6 ppm which is still effective in controlling bacterial contamination. CONCLUSION Continuously supplying iodine in DUWLs effectively controls microbial contamination.
Collapse
Affiliation(s)
- Chatchaya Petchphayaprai
- Center of Excellence on Oral Microbiology and Immunology, Department of Microbiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Chutimon Chotipan
- Center of Excellence on Oral Microbiology and Immunology, Department of Microbiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Pitchayapa Sa-Ngiampak
- Center of Excellence on Oral Microbiology and Immunology, Department of Microbiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Kittisak Thotsaporn
- Department of Biochemistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
| | | |
Collapse
|
9
|
Marino F, Mazzotta M, Pascale MR, Derelitto C, Girolamini L, Cristino S. First water safety plan approach applied to a Dental Clinic complex: identification of new risk factors associated with Legionella and P. aeruginosa contamination, using a novel sampling, maintenance and management program. J Oral Microbiol 2023; 15:2223477. [PMID: 37346998 PMCID: PMC10281406 DOI: 10.1080/20002297.2023.2223477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 05/18/2023] [Accepted: 06/06/2023] [Indexed: 06/23/2023] Open
Abstract
Dental unit waterlines (DUWLs) represent a complex environment able to promote microbial contamination, due to functional, mechanical and practical risk factors. According to a water safety plan approach, the main goal is to preserve the health of dentists, dental staff and patients. The aim of this study is to develop a DUWLs water safety plan that is able to support correct and effective maintenance and disinfection procedures. Three different water systems serve 60 dental chairs: (i) water that comes directly from municipal water (Type A), (ii) water supplied by municipal water and water bottles (Type B) and (iii) water supplied only via water bottles (Type C). For each type, Legionella and Pseudomonas aeruginosa contamination was studied, by applying a new sampling scheme, based on separate sampling from water bottles, cup filler and handpieces. Type B DUWL is the only type of DUWL contaminated by L. pneumophila (ST 59) and L. anisa (mean contamination: 608.33 ± 253.33 cfu/L) detected in cup filler and handpieces, as well as the high presence of P. aeruginosa (44.42 ± 13.25 cfu/100 mL). Two subsequent shock treatments and resampling procedures were performed by increasing disinfectant dosage and contact time and removing some DUWL components linked to biofilm growth in DUWLs. A significant reduction of contamination was obtained for both microorganisms (Legionella spp.: -100%, p < 0.001 and P. aeruginosa: -99.86%, p = 0.006). The sampling strategy proposed allows us to identify the source of contamination and better focus on the maintenance and disinfection procedures. DUWLs represent an environment that requires a multidisciplinary approach, combining the knowledge of all DUWL components to correct procedures that are able to preserve the health of personnel and patients, as well as guaranteeing DUWLs' safe functionality.
Collapse
Affiliation(s)
- Federica Marino
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Marta Mazzotta
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Maria Rosaria Pascale
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
- Department of Civil, Chemical, Environmental and Materials Engineering, University of Bologna, Bologna, Italy
| | - Carlo Derelitto
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Luna Girolamini
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Legionella Infections (ESGLI), Basel, Switzerland
| | - Sandra Cristino
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Legionella Infections (ESGLI), Basel, Switzerland
| |
Collapse
|
10
|
Weber J, Bonn EL, Auer DL, Kirschneck C, Buchalla W, Scholz KJ, Cieplik F. Preprocedural mouthwashes for infection control in dentistry-an update. Clin Oral Investig 2023:10.1007/s00784-023-04953-z. [PMID: 37079156 PMCID: PMC10116478 DOI: 10.1007/s00784-023-04953-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 03/17/2023] [Indexed: 04/21/2023]
Abstract
OBJECTIVES Aerosols and splatter are routinely generated in dental practice and can be contaminated by potentially harmful bacteria or viruses such as SARS-CoV-2. Therefore, preprocedural mouthwashes containing antiseptic agents have been proposed as a potential measure for infection control in dental practice. This review article aims to summarize the clinical (and, if insufficient, preclinical) evidence on preprocedural mouthwashes containing antiseptic agents and to draw conclusions for dental practitioners. METHODS Literature on preprocedural mouthwashes for reduction of bacterial or viral load in dental aerosols was searched and summarized. RESULTS Preprocedural mouthwashes, particularly those containing chlorhexidine digluconate (CHX), cetylpyridinium chloride (CPC), or essential oils (EO), can significantly reduce the bacterial load in dental aerosols. With respect to viruses such as HSV-1, there are too little clinical data to draw any clear recommendations. On the other hand, clinical data is consolidating that CPC-containing mouthwashes can temporarily reduce the intraoral viral load and infectivity in SARS-CoV-2 positive individuals. Nevertheless, potential risks and side effects due to regular antiseptic use such as ecological effects or adaptation of bacteria need to be considered. CONCLUSIONS The use of preprocedural mouthwashes containing antiseptics can be recommended according to currently available data, but further studies are needed, particularly on the effects on other viruses besides SARS-CoV-2. When selecting a specific antiseptic, the biggest data basis currently exists for CHX, CPC, EO, or combinations thereof. CLINICAL RELEVANCE Preprocedural mouthwashes containing antiseptics can serve as part of a bundle of measures for protection of dental personnel despite some remaining ambiguities and in view of potential risks and side effects.
Collapse
Affiliation(s)
- Johanna Weber
- Department of Conservative Dentistry and Periodontology, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany
- Department of Orthodontics, University Hospital Regensburg, Regensburg, Germany
| | - Eva L Bonn
- Department of Conservative Dentistry and Periodontology, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany
| | - David L Auer
- Department of Conservative Dentistry and Periodontology, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany
| | | | - Wolfgang Buchalla
- Department of Conservative Dentistry and Periodontology, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany
| | - Konstantin J Scholz
- Department of Conservative Dentistry and Periodontology, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany
| | - Fabian Cieplik
- Department of Conservative Dentistry and Periodontology, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany.
| |
Collapse
|
11
|
Xing M, Zhang H, Zhang L, Qian W. Construction of ZnO/PCL Antibacterial Coating Potentially for Dental Unit Waterlines. J Funct Biomater 2023; 14:jfb14040225. [PMID: 37103315 PMCID: PMC10144832 DOI: 10.3390/jfb14040225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 04/04/2023] [Accepted: 04/13/2023] [Indexed: 04/28/2023] Open
Abstract
The formation of bacterial biofilms and the contamination of treatment water within dental unit waterlines can lead to a risk of secondary bacterial infections in immunocompromised patients. Although chemical disinfectants can reduce the contamination of treatment water, they can also cause corrosion damage to dental unit waterlines. Considering the antibacterial effect of ZnO, a ZnO-containing coating was prepared on the surface of polyurethane waterlines using polycaprolactone (PCL) with a good film-forming capacity. The ZnO-containing PCL coating improved the hydrophobicity of polyurethane waterlines, thus inhibiting the adhesion of bacteria. Moreover, the continuous slow release of Zn ions endowed polyurethane waterlines with antibacterial activity, thus effectively preventing the formation of bacterial biofilms. Meanwhile, the ZnO-containing PCL coating had good biocompatibility. The present study suggests that ZnO-containing PCL coating can realize a long-term antibacterial effect on the polyurethane waterlines by itself, providing a novel strategy for the manufacture of autonomous antibacterial dental unit waterlines.
Collapse
Affiliation(s)
- Min Xing
- Shanghai Xuhui District Dental Center, Shanghai 200032, China
| | - Haifeng Zhang
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China
| | - Ling Zhang
- Shanghai Xuhui District Dental Center, Shanghai 200032, China
| | - Wenhao Qian
- Shanghai Xuhui District Dental Center, Shanghai 200032, China
| |
Collapse
|
12
|
Hong F, Chen P, Yu X, Chen Q. The Application of Silver to Decontaminate Dental Unit Waterlines-a Systematic Review. Biol Trace Elem Res 2022; 200:4988-5002. [PMID: 34997534 PMCID: PMC8741583 DOI: 10.1007/s12011-022-03105-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Accepted: 01/03/2022] [Indexed: 11/26/2022]
Abstract
The contamination of dental unit waterlines (DUWLs) is a major health concern since it can pose cross-infection risks among dental professionals and their patients. Silver is one of the widely used metals in medical fields due to its superior antimicrobial properties. Silver-based agents have been commercially available for the decontamination of dental unit water currently. This systematic review aims to examine the evidence supporting efficacy and safety of application of silver to decontaminate DUWLs. We performed a search of the peer-review literature of studies in six electronic databases using corresponding search terms. Eligibility was restricted to English-language studies exploring the application of silver to decontaminate dental unit water, e.g., silver-based disinfectants and silver-coated dental waterlines tubing. The search identified 148 articles, and 9 articles that met the criteria were synthesized with qualitative narrative analyses. We observed good evidence of antimicrobial efficacy of silver with hydrogen peroxide on diverse microorganism present in DUWLs. Furthermore, there is insufficient evidence on the application of silver nanoparticles (AgNPs) as an efficient material to control the biofilms in DUWLs. Post-treatment data of either the bactericidal and bacteriostatic effects of silver or AgNPs, especially the actual clinical efficacy of long-term application, are scarce. More high-quality research is needed to resolve the gap on the optimal dosage and treatment options required to control bacterial and biofilm in DUWLs with silver-containing materials.
Collapse
Affiliation(s)
- Feiruo Hong
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, 310000, Zhejiang, China
- School of Medicine, Zhejiang University, Hangzhou, 310000, Zhejiang, China
| | - Piaopiao Chen
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, 310000, Zhejiang, China
- School of Medicine, Zhejiang University, Hangzhou, 310000, Zhejiang, China
| | - Xuefen Yu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, 310000, Zhejiang, China.
| | - Qianming Chen
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, 310000, Zhejiang, China
| |
Collapse
|
13
|
Totaro M, Badalucco F, Papini F, Grassi N, Mannocci M, Baggiani M, Tuvo B, Casini B, Menchini Fabris GB, Baggiani A. Effectiveness of a Water Disinfection Method Based on Osmosis and Chlorine Dioxide for the Prevention of Microbial Contamination in Dental Practices. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:10562. [PMID: 36078275 PMCID: PMC9518534 DOI: 10.3390/ijerph191710562] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 08/17/2022] [Accepted: 08/23/2022] [Indexed: 06/15/2023]
Abstract
In dental clinics, the infections may be acquired through contaminated devices, air, and water. Aerosolized water may contain bacteria, grown into the biofilm of dental unit waterlines (DUWLs). We evaluated a disinfection method based on water osmosis and chlorination with chlorine dioxide (O-CD), applied to DUWL of five dental clinics. Municipal water was chlorinated with O-CD device before feeding all DUWLs. Samplings were performed on water/air samples in order to research total microbial counts at 22-37 °C, Pseudomonas aeruginosa, Legionella spp., and chlorine values. Water was collected from the taps, spittoons, and air/water syringes. Air was sampled before, during, and after 15 min of aerosolizing procedure. Legionella and P. aeruginosa resulted as absent in all water samples, which presented total microbial counts almost always at 0 CFU/mL. Mean values of total chlorine ranged from 0.18-0.23 mg/L. Air samples resulted as free from Legionella spp. and Pseudomonas aeruginosa. Total microbial counts decreased from the pre-aerosolizing (mean 2.1 × 102 CFU/m3) to the post-aerosolizing samples (mean 1.5 × 10 CFU/m3), while chlorine values increased from 0 to 0.06 mg/L. O-CD resulted as effective against the biofilm formation in DUWLs. The presence of residual activity of chlorine dioxide also allowed the bacteria reduction from air, at least at one meter from the aerosolizing source.
Collapse
Affiliation(s)
- Michele Totaro
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Federica Badalucco
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Francesca Papini
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Niccolò Grassi
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Marina Mannocci
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | | | - Benedetta Tuvo
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Beatrice Casini
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | | | - Angelo Baggiani
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| |
Collapse
|
14
|
Deasy E, Scott T, Swan J, O’donnell M, Coleman D. Effective cleaning and decontamination of the internal air and water channels, heads and head-gears of multiple contra angle dental handpieces using an enzymatic detergent and automated washer disinfection in a dental hospital setting. J Hosp Infect 2022; 128:80-88. [DOI: 10.1016/j.jhin.2022.07.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 07/21/2022] [Accepted: 07/21/2022] [Indexed: 11/16/2022]
|
15
|
Wu M, Shi Z, Yu X, Xu Y, Jin X, Zhang L, Fu B. Disinfection methods of dental unit waterlines contamination: a systematic review. J Med Microbiol 2022; 71. [PMID: 35670283 DOI: 10.1099/jmm.0.001540] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Background. Severe contamination of dental unit waterlines was found in healthcare settings. The benefits of decontamination methods are controversial. The aim of this review was to systematically evaluate disinfection methods in contamination control of dental unit waterlines.Methods. The terms 'dental unit waterline(s) or DUWL(s) or dental unit water line(s)' were searched through PubMed, Cochrane Library, Embase, Web of Science and Scopusup to 31 May 2021. The DUWLs' output water was incubated on R2A agar at 20-28 °C for 5-7 days to evaluate heterotrophic mesophilic bacteria. The risk of bias was evaluated by a modified Newcastle-Ottawa quality assessment scale.Results. Eighteen papers from the literature were included. One study indicated that water supply played a crucial role in disinfecting DUWLs. Three studies indicated that flushing decreased bacteria counts but did not meet the American CDC standard (500 c.f.u. ml-1). All chlorine- and peroxide-containing disinfectants except sodium hypochlorite in one of 15 studies as well as three mouthrinses and citrus botanical extract achieved the standard (≤500 c.f.u. ml-1). The included studies were of low (1/18), moderate (6/18) and high (11/18) quality.Conclusion. Independent water reservoirs are recommended for disinfecting DUWLs using distilled water. Flushing DUWLs should be combined with disinfections. Nearly all the chlorine-, chlorhexidine- and peroxide-containing disinfectants, mouthrinses and citrus botanical extract meet the standard for disinfecting DUWLs. Alkaline peroxide would lead to tube blockage in the DUWLs. Regularly changing disinfectants can reduce the risk of occurrence of disinfectant-resistant strains of microbes.
Collapse
Affiliation(s)
- Mengting Wu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| | - Zhiwei Shi
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| | - Xuefen Yu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| | - Yuedan Xu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| | - Xinyang Jin
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| | - Ling Zhang
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| | - Baiping Fu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310006, PR China
| |
Collapse
|
16
|
Microbiological Evaluation of Water Used in Dental Units. WATER 2022. [DOI: 10.3390/w14060915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
In modern dentistry, dental units are used for the treatment of patients’ teeth, and they need water to operate. Water circulates in a closed vessel system and finally reaches the mucous membranes of the patient as well as the dentist themselves. Therefore, the microbiological safety of this water should be a priority for physicians. This study aims to identify and determine the microbial count, expressed in CFU/mL, in water samples from various parts of the dental unit that are in direct contact with the patient. Thirty-four dental units located in dentistry rooms were analysed. The dentistry rooms were divided into three categories: surgical, conservative, and periodontal. It was found that in surgical rooms, the bacterial count was 1464.76 CFU/mL, and the most common bacterium was Staphylococcus pasteuri—23.88% of the total bacteria identified. In dentistry rooms where conservative treatments were applied, the average bacterial concentration was 8208.35 CFU/mL, and the most common bacterium was Ralsonia pickettii (26.31%). The periodontal rooms were also dominated by R. pickettii (45.13%), and the average bacterial concentration was 8743.08 CFU/mL. Fungi were also detected. Rhodotorula spp., Alternaria spp., and Candida parapsilosis were found to be the most common bacteria which are potentially harmful. This study indicates the need for effective decontamination of the water that is used in dental units and for constant monitoring of the level of contaminants present in the closed vessel system.
Collapse
|
17
|
Fan C, Gu H, Liu L, Zhu H, Yan J, Huo Y. Distinct Microbial Community of Accumulated Biofilm in Dental Unit Waterlines of Different Specialties. Front Cell Infect Microbiol 2021; 11:670211. [PMID: 34222041 PMCID: PMC8248794 DOI: 10.3389/fcimb.2021.670211] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Accepted: 05/31/2021] [Indexed: 12/26/2022] Open
Abstract
The contamination of dental unit waterlines (DUWLs) is a serious problem and directly affects the dental care. This study aims to explore the microbial community of biofilm in DUWL from different specialties and investigate the associated factors. A total of 36 biofilm samples from 18 DUWL of six specialties (i.e., prosthodontics, orthodontics, pediatrics, endodontics, oral surgery, and periodontics) at two time points (i.e., before and after daily dental practice) were collected with a novel method. Genomic DNA of samples was extracted, and then 16S ribosomal DNA (rDNA) (V3–V4 regions) and ITS2 gene were amplified and sequenced. Kruskal–Wallis and Wilcoxon rank test were adopted for statistical analysis. Microbial community with high diversity of bacteria (631 genera), fungi (193 genera), and viridiplantae was detected in the biofilm samples. Proteobacteria was the dominant bacteria (representing over 65.74–95.98% of the total sequences), and the dominant fungi was Ascomycota (93.9–99.3%). Microorganisms belonging to multiple genera involved in human diseases were detected including 25 genera of bacteria and eight genera of fungi, with relative abundance of six genera over 1% (i.e., Acinetobacter, Pseudomonas, Enterobacter, Aspergillus, Candida, and Penicillium). The biofilm microbiome may be influenced by the characteristics of dental specialty and routine work to some extent. The age of dental chair unit and overall number of patients had the strongest impact on the overall bacteria composition, and the effect of daily dental practices (associated with number of patients and dental specialty) on the fungi composition was the greatest. For the first time, biofilm in DUWL related to dental specialty was comprehensively evaluated, with more abundance of bacterial and fungal communities than in water samples. Biofilm accumulation with daily work and multiple kinds of opportunistic pathogen emphasized the infectious risk with dental care and the importance of biofilm control.
Collapse
Affiliation(s)
- Cancan Fan
- Zhujiang New Town Clinic, Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Haijing Gu
- Zhujiang New Town Clinic, Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Limin Liu
- Zhujiang New Town Clinic, Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Haiwei Zhu
- Zhujiang New Town Clinic, Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Juan Yan
- Zhujiang New Town Clinic, Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Yongbiao Huo
- Zhujiang New Town Clinic, Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| |
Collapse
|
18
|
Risk Perception of SARS-CoV-2 Infection and Implementation of Various Protective Measures by Dentists Across Various Countries. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18115848. [PMID: 34072456 PMCID: PMC8199051 DOI: 10.3390/ijerph18115848] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 05/19/2021] [Accepted: 05/26/2021] [Indexed: 01/19/2023]
Abstract
Objective: Healthcare workers in general are at a high risk of potential infections with COVID-19, especially those who work with aerosol generating procedures. Dentists fall in this category, as not only do they operate with aerosol generating procedures but also operate within a face-to-face contact area. Methods: A structured self-administered questionnaire was developed at Najran University and provided to the participants for data collection. The data collected included information on risk perception and incorporation of measures for protection against COVID-19 to gauge the attitude of dentists during this period. Also, clinical implementation of various protective measures was reviewed. Results: Of the n = 322 dentists that answered the questions, 50% were general dentists and 28.9% were dentists working at specialist clinics, while the remaining 21.1% of dentists were employed in academic institutions. Among the newer additions to the clinic, 36.3% of dentists answered that they had added atomizers to their practices, followed by 26.4% of dentists that had incorporated the use of UV lamps for sterilization. We found that 18.9% dentists were using HEPA filters in their clinics, while 9.9% of dentists were making use of fumigation devices to control the risk of infection. One-way ANOVA was also carried out to demonstrate that there was a statistically significant difference (p = 0.049) between groups of dentists utilizing HEPA filters, UV lamps, atomizers, and fumigation devices to prevent the spread of SARS-CoV2 across their workplaces. Conclusion: Dentists are aware of recently updated knowledge about the modes of transmission of COVID-19 and the recommended infection control measures in dental settings. A better understanding of the situation and methods to prevent it will ensure that the dental community is able to provide healthcare services to patients during the pandemic.
Collapse
|
19
|
Yiek WK, Coenen O, Nillesen M, van Ingen J, Bowles E, Tostmann A. Outbreaks of healthcare-associated infections linked to water-containing hospital equipment: a literature review. Antimicrob Resist Infect Control 2021; 10:77. [PMID: 33971944 PMCID: PMC8108015 DOI: 10.1186/s13756-021-00935-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 04/09/2021] [Indexed: 01/27/2023] Open
Abstract
BACKGROUND Healthcare-associated infections (HAIs) are a significant cause of morbidity and mortality in hospitalized patients. Water in the environment can be a source of infection linked to outbreaks and environmental transmission in hospitals. Water safety in hospitals remains a challenge. This article has summarized available scientific literature to obtain an overview of outbreaks linked to water-containing hospital equipment and strategies to prevent such outbreaks. METHODS We made a list of water-containing hospital equipment and devices in which water is being used in a semi-closed circuit. A literature search was performed in PubMed with a search strategy containing the names of these medical devices and one or more of the following words: outbreak, environmental contamination, transmission, infection. For each medical device, we summarized the following information: the function of the medical device, causes of contamination, the described outbreaks and possible prevention strategies. RESULTS The following water-containing medical equipment or devices were identified: heater-cooler units, hemodialysis equipment, neonatal incubators, dental unit waterlines, fluid warmers, nebulizers, water traps, water baths, blanketrol, scalp cooling, and thermic stimulators. Of the latter three, no literature could be found. Of all other devices, one or more outbreaks associated with these devices were reported in the literature. CONCLUSIONS The water reservoirs in water-containing medical devices can be a source of microbial growth and transmissions to patients, despite the semi-closed water circuit. Proper handling and proper cleaning and disinfection can help to reduce the microbial burden and, consequently, transmission to patients. However, these devices are often difficult to clean and disinfect because they cannot be adequately opened or disassembled, and the manufacturer's cleaning guidelines are often not feasible to execute. The development of equipment without water or fluid containers should be stimulated. Precise cleaning and disinfection guidelines and instructions are essential for instructing healthcare workers and hospital cleaning staff to prevent potential transmission to patients.
Collapse
Affiliation(s)
- Wing-Kee Yiek
- Department of Medical Microbiology, Radboud Centre for Infectious Diseases, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Olga Coenen
- Department of Medical Microbiology, Radboud Centre for Infectious Diseases, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Mayke Nillesen
- Department of Medical Microbiology, Radboud Centre for Infectious Diseases, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Jakko van Ingen
- Department of Medical Microbiology, Radboud Centre for Infectious Diseases, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Edmée Bowles
- Department of Medical Microbiology, Radboud Centre for Infectious Diseases, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Alma Tostmann
- Department of Medical Microbiology, Radboud Centre for Infectious Diseases, Radboud University Medical Centre, Nijmegen, The Netherlands.
| |
Collapse
|
20
|
Comisi JC, Ravenel TD, Kelly A, Teich ST, Renne W. Aerosol and spatter mitigation in dentistry: Analysis of the effectiveness of 13 setups. J ESTHET RESTOR DENT 2021; 33:466-479. [PMID: 33522677 PMCID: PMC8014276 DOI: 10.1111/jerd.12717] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Accepted: 01/19/2021] [Indexed: 01/08/2023]
Abstract
OBJECTIVES The current study aims to investigate the aerosol and spatter mitigation quality of 13 dry-field isolation methods in a simulated setup that replicates real-life work scenarios encountered in dental practices. METHODS A crown preparation on a manikin was performed on tooth number 30 and repeated five times for each setup to simulate a patient under care. Aerosol, environmental, and operator face shield spatter, and sound intensity was measured. Generalized linear mixed models were used, and posthoc pairwise comparisons were performed to compare least-squares means when appropriate using a Tukey adjustment. RESULTS All tested setups showed some environmental spatter formation; however, these were able to control most (and in some cases all) spatter on the operator face shield. All methods resulted in excellent aerosol mitigation when a second line of high-volume evacuation (HVE) was added to the device setup. However, in most setups, total sound levels exceeded 85 dB, posing a concern for prolonged noise exposure. CONCLUSIONS The Prototype device and four other tested setups with secondary HVE addition completely eliminated aerosol creation as tested. Spatter of the Face Shield was best eliminated using the Prototype device. CLINICAL SIGNIFICANCE Within the limitations of this study, it can be concluded that the dental community has at its disposal equipment that can effectively mitigate aerosol and spatter.
Collapse
Affiliation(s)
- John C Comisi
- Medical University of South Carolina, James B. Edwards College of Dental Medicine, Charleston, South Carolina, USA
| | - Theodore D Ravenel
- Medical University of South Carolina, James B. Edwards College of Dental Medicine, Charleston, South Carolina, USA
| | - Abigail Kelly
- Medical University of South Carolina, James B. Edwards College of Dental Medicine, Charleston, South Carolina, USA
| | - Sorin T Teich
- Medical University of South Carolina, James B. Edwards College of Dental Medicine, Charleston, South Carolina, USA
| | - Walter Renne
- Medical University of South Carolina, James B. Edwards College of Dental Medicine, Charleston, South Carolina, USA
| |
Collapse
|
21
|
Aldahlawi SA, Afifi IK. COVID-19 in Dental Practice: Transmission Risk, Infection Control Challenge, and Clinical Implications. Open Dent J 2020. [DOI: 10.2174/1874210602014010348] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Objective:
The COVID-19 pandemic has become a worldwide, significant public health challenge. Dental care providers are at high risk due to the nature of their profession, which necessitates close proximity to the patient's oropharyngeal region and the use of droplet and aerosol-generating procedures.
Methods:
A review of the evolving literature on the COVID-19 pandemic was conducted. Published articles addressing SARS-CoV2 transmission modes and risks, and infection control procedures required in the dental office to protect dental patients and health care providers were assessed. Also, clinical guidelines on the management of dental patients during the pandemic were reviewed.
Results:
The established modes of transmission of SARS-CoV2 appear to be through respiratory droplets and through close contact with either symptomatic or asymptomatic patients. In addition to standard precautions of infection control widely followed in dental practices, extra precautionary measures are needed to control the spread of this highly infectious disease. Dental treatment during the pandemic is limited to emergent and urgent cases after a meticulous patient risk assessment and dental needs are triaged to minimize the risk of COVID-19 transmission and avoid cross-contamination.
Conclusion:
Dentists should be aware of the recently updated knowledge about COVID-19 modes of transmission and the recommended infection control measures in dental settings. Effective management protocols to regulate droplet and aerosol contamination in the dental clinic should be implemented to deliver dental care in a safe environment.
Collapse
|
22
|
Zemouri C, Laheij AMGA, Volgenant CMC, Brandt BW, Crielaard W, Buijs MJ, Zaura E, de Soet JJ. Chlorine-based DUWL disinfectant leads to a different microbial composition of water derived biofilms compared to H 2O 2-based chemical disinfectants in vitro. PeerJ 2020; 8:e9503. [PMID: 32742792 PMCID: PMC7368430 DOI: 10.7717/peerj.9503] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Accepted: 06/17/2020] [Indexed: 02/06/2023] Open
Abstract
Background Biofilm formation in dental unit waterlines (DUWL) may lead to health risks for dental staff and patients. Therefore, dental unit waterlines need to be disinfected, for instance by using chemical disinfectants. However, the application of chemical disinfectants may lead to the selection of specific microorganisms. Therefore, the aim of our study was to assess the microbial composition of water-derived biofilms, after a continuous exposure to maintenance doses of commercially available chemical disinfectants, in vitro. Methods The AAA-model was used to grow water derived biofilms. The biofilms were subjected to the maintenance dose of each disinfectant. To determine the microbial composition, the V4 hypervariable region of the 16S rRNA gene was sequenced. The sequences were clustered in operational taxonomic units (OTUs). Results The bacterial composition of biofilms in all treatment groups differed significantly (PERMANOVA F = 4.441, p = 0.001). Pairwise comparisons revealed Anoxyl treated biofilms were significantly different from all groups (p = 0.0001). In the Anoxyl-treated biofilms, the relative abundance of Comamonadaceae and Sphingopyxis was high compared to the Dentosept, Green and Clean and Oxygenal groups. Conclusion We concluded that exposure to low doses of the chlorine-based chemical disinfectant Anoxyl led to a substantially different composition of water derived biofilms compared to biofilms exposed to H2O2-based chemical disinfectants.
Collapse
Affiliation(s)
- Charifa Zemouri
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - Alexa M G A Laheij
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - Catherine M C Volgenant
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - Bernd W Brandt
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - Wim Crielaard
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - Mark J Buijs
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - Egija Zaura
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - Johannes J de Soet
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
23
|
Okubo K, Ito T, Okamoto K, Yamamoto I, Mizutani H, Kawata Y, Shiota Y, Ito M, Nakamura S, Tai M, Yamamoto T, Takashiba S. Evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines. Heliyon 2020; 6:e04132. [PMID: 32566782 PMCID: PMC7298401 DOI: 10.1016/j.heliyon.2020.e04132] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 08/04/2019] [Accepted: 06/01/2020] [Indexed: 11/24/2022] Open
Abstract
The prevention of nosocomial infections is an imperative task. The dental chair unit (DCU) is an indispensable device used in dental treatment. However, it is known that the dental unit water line (DUWL) can become contaminated with biofilm, consisting mainly of heterotrophic bacteria (HB). Recently, the International Organization for Standardization specified the methods for testing DUWL contamination management. On these grounds, a simulator reproducing DUWL was prepared to standardize the examination method of the DUWL contamination. Objectives To evaluate the reproducibility of the DUWL simulator, monitor the DUWL contamination states, and test the efficacy of a commercial decontaminant for DUWL. Methods The DUWL simulator was assembled by a DCU manufacturing company. The simulator's DUWL was filled with tap water (TW), and left for approximately one year. Neutral electrolyzed water (NEW) was used as a decontaminant for DUWL. Both TW and NEW were passed through DUWL in a timely manner simulating daily dental treatment. Water was sampled from the air turbine hand piece weekly for 4 weeks and used for HB culture. Contamination status was evaluated by measuring bacterial adenosine triphosphate release and by culturing on Reasoner's 2A medium. Results The DUWL released contaminated water had a bacterial count of over 6 × 104 cfu/mL. After passing NEW through DUWL for 1 week, the count drastically decreased to its basal level and remained steady for 4 weeks. However, TW showed no effect on DUWL decontamination throughout the examination periods. Conclusions The DUWL simulator could be useful to examine the efficacy of the decontaminant for DUWL and development of new methods in DUWL contamination management.
Collapse
Affiliation(s)
- Keisuke Okubo
- Department of Pathophysiology - Periodontal Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8558, Japan.,Division of Dentistry, Tottori Municipal Hospital, 1-1 Matoba Tottori, Tottori 680-0501, Japan
| | - Takashi Ito
- Center for Innovative Clinical Medicine, Okayama University Hospital, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8558, Japan
| | - Kentaro Okamoto
- Department of Pathophysiology - Periodontal Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8558, Japan
| | - Ichiro Yamamoto
- Dental Department Marketing Division, TAKARA BELMONT Corporation, 2-1-1 Higashishinsaibashi, Chuo-ku, Osaka 542-0083, Japan
| | - Hajime Mizutani
- Research and Development Department, TAKARA BELMONT Corporation, 2-1-1 Higashishinsaibashi, Chuo-ku, Osaka 542-0083, Japan
| | - Yusuke Kawata
- Department of Periodontics and Endodontics, Okayama University Hospital, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8558, Japan
| | - Yasuyoshi Shiota
- Department of Pathophysiology - Periodontal Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8558, Japan
| | - Masahiro Ito
- Department of Periodontics and Endodontics, Okayama University Hospital, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8558, Japan
| | - Shin Nakamura
- Department of Periodontics and Endodontics, Okayama University Hospital, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8558, Japan
| | - Masako Tai
- Department of Periodontics and Endodontics, Okayama University Hospital, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8558, Japan
| | - Tadashi Yamamoto
- Department of Pathophysiology - Periodontal Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8558, Japan
| | - Shogo Takashiba
- Department of Pathophysiology - Periodontal Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8558, Japan
| |
Collapse
|
24
|
Comparative Evaluation of Efficacy of Chlorhexidine and Herbal Mouthwash as a Preprocedural Rinse in Reducing Dental Aerosols: A Microbiological Study. Int J Dent 2020. [DOI: 10.1155/2020/2021082] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Objective. The risk to dentists, assistants, and patients of infectious diseases through aerosols has long been recognized. The aim of this study was to evaluate and compare the efficacy of commercially available preprocedural mouth rinses containing 0.2% chlorhexidine (CHX) gluconate, Befresh™ herbal mouthwash, and water in reducing the levels of viable bacteria in aerosols. Materials & Methods. This was a single-center, double-masked, placebo-controlled, randomized, three-group parallel design study. 30 patients (10 patients in each group) were recruited in the study. Patient rinsed mouth with 10 ml of CHX, 10 ml Befresh™, or 10 ml water. All the patients underwent supragingival ultrasonic scaling for a minimum of 30 min. The aerosol collection was done using a blood agar plate. The blood agar plates were kept approximately 12 inches from the patient’s mouth. The microbial culture was analyzed. The colony-forming unit (CFU) counting in all three groups was assessed using one-way ANOVA test to compare among the groups (p value <0.001). The intergroup comparison was done using the post hoc Tukey test. Result. There was a marked reduction in the CFU in the CHX group in all three areas. This was followed by Befresh™ (Sagar Pharmaceuticals) mouthwash. There was no reduction in the CFU of the water group. Conclusion. This study proves that a regular preprocedural mouth rinse could significantly reduce the majority bacteria present in aerosols generated by the use of an ultrasonic unit, and Befresh™ mouth rinse was found to be equally effective in reducing the aerosol contamination to 0.2% CHX gluconate.
Collapse
|
25
|
Zemouri C, de Soet JJ, Volgenant CMC, Crielaard W, Laheij AMGA. Heterogeneity in the efficacy of dental chemical disinfectants on water-derived biofilms in vitro. BIOFOULING 2020; 36:587-596. [PMID: 32580580 DOI: 10.1080/08927014.2020.1782894] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Revised: 05/29/2020] [Accepted: 06/08/2020] [Indexed: 06/11/2023]
Abstract
Conditions in dental unit waterlines are favourable for biofilm growth and contamination of dental unit water. The aim of this study was to assess the effect of several chemical disinfectants on bacteria in a biofilm model. Water-derived biofilms were grown in a static biofilm model (Amsterdam Active Attachment model), using two growth media. Biofilms were challenged with Alpron/Bilpron, Anoxyl, Citrisil, Dentosept, Green & Clean, ICX and Oxygenal in shock dose and maintenance doses. The concentration and the composition of the chemical disinfectants influenced the number of culturable bacteria in the biofilms. The application of a single shock dose followed by a low dose of the same chemical disinfectants resulted in the greatest suppression of viable bacteria in the biofilms. Exposure to Citrisil and ICX consistently resulted in failure to control the biofilms, while Alpron/Bilpron had a substantial and relevant effect on the number of bacteria in the biofilms.
Collapse
Affiliation(s)
- C Zemouri
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - J J de Soet
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - C M C Volgenant
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - W Crielaard
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - A M G A Laheij
- Department of Preventive Dentistry, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
26
|
Cheng L, Naibijiang N, Hasenbai A, Dong H, He H. Bacteriostatic effects of nanometer silver disinfectant on the biofilms in dental unit water lines. J Dent Sci 2020; 16:327-332. [PMID: 33384816 PMCID: PMC7770243 DOI: 10.1016/j.jds.2020.03.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 03/30/2020] [Indexed: 01/10/2023] Open
Abstract
Background/purpose Dental unit water lines (DUWLs) may be contaminated by aerobic bacteria in clinical settings and comprehensive disinfecting methods should be considered without delay. Herein, this study aims to investigate the timeliness and dynamic bacteriostatic effects of different forms of nanometer silver (NMS) disinfectant on bio-film in DUWLs. Materials and methods Bacterial DUWLs samples were respectively treated with different NMS forms, including liquid phase and solid phase at the concentrations of 0.25%, 0.5%, 1% and 2% and their bacteriostatic effects were observed at the 1st, 4th, 7th, 14th, 28th day. Results The bacteriostatic effects of liquid phase NMS at all concentrations were unsatisfactory and the bacteriostatic rate was only 20% at the 1st day. However, there appeared massive bacteria growth at the 4th, 7th, 14th, 28th day. Comparatively, no bacteria growth was found at the 1st, 4th, 7th, 14th, 28th day after sterilizing with different concentrations of solid phase NMS and the bacteriostatic rate was 100%. Conclusion Microbial contamination in DUWLs can be disinfected by different NMS forms, among which solid phase NMS is more bactericidal against bacteria bio-films, demonstrating significant roles of solid phase NMS in preventing DUWL contamination.
Collapse
Affiliation(s)
- Lujin Cheng
- Department of Stomatology, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang Uyghur Autonomous Region, People's Republic of China
| | - Nijiatijiang Naibijiang
- Urumqi Stomatology Hospital, Urumqi, Xinjiang Uyghur Autonomous Region, People's Republic of China
| | - Aletengguli Hasenbai
- Department of Stomatology, The People's Hospital of Guoerguosi, Guoerguosi, Xinjiang Uyghur Autonomous Region, People's Republic of China
| | - Hongbin Dong
- Department of Stomatology, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang Uyghur Autonomous Region, People's Republic of China
| | - Huiyu He
- Department of Stomatology, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang Uyghur Autonomous Region, People's Republic of China
| |
Collapse
|
27
|
Ji XY, Ning PY, Fei CN, Liu J, Liu H, Song J. The importance of sampling technique and rinse water for assessing flexible gastrointestinal endoscope reprocessing: A 3-year study covering 59 centers. Am J Infect Control 2020; 48:19-25. [PMID: 31400884 DOI: 10.1016/j.ajic.2019.07.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Revised: 07/11/2019] [Accepted: 07/11/2019] [Indexed: 01/12/2023]
Abstract
BACKGROUND Various guidelines recommend several sampling techniques to verify endoscope reprocessing, but a comparative study of the efficiency for recovering microorganisms was rare. Our goal was to compare different sampling techniques for the postreprocessing endoscope to assess residual bacterial contamination and analysis of the critical factors affecting the endoscope reprocessing failure. METHODS From 2016 to 2018, 3 techniques, the conventional flushing sampling method, flush-brush-flush sampling method (FBFSM), and pump-assisted sampling method (PASM), were compared covering all 59 endoscope units in Tianjin, China. RESULTS A total of 237 (84.64%) flushing channel samples and 110 (61.11%) final rinse water samples met the Chinese national standard. The univariate analysis showed that the qualified rates of endoscope reprocessing sampled by PASM (65.52%) and FBFSM (75%) were significantly lower than those of the conventional flushing sampling method (91.38%). Five other factors, including the final rinse water, dry, and hospital level, were potential factors besides sample technique. The multivariate logistic analysis indicated only 2 factors (sampling technique and final rinse water) remained in the model. FBFSM, PASM, and the purified water were significantly associated with the odds of endoscope reprocessing failure, with the odds ratio (95% confidence interval) of which were 4.206 (1.757-10.067), 5.326 (2.463-11.645), and 0.309 (0.137-0.695), respectively. CONCLUSIONS The problem of residual microorganisms of the postreprocessing endoscope was severe. Sampling technique and final rinse water were critical for endoscope reprocessing verification.
Collapse
|
28
|
Baudet A, Lizon J, Martrette JM, Camelot F, Florentin A, Clément C. Dental Unit Waterlines: A Survey of Practices in Eastern France. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:E4242. [PMID: 31683783 PMCID: PMC6862618 DOI: 10.3390/ijerph16214242] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 10/24/2019] [Accepted: 10/30/2019] [Indexed: 11/16/2022]
Abstract
Water is essential during dental care. Physical and chemical techniques should be used to maintain a good water quality with respect to bacteria, and to ensure the safety of exposed patients and dental staff. The aim of this survey was to assess the modalities used by dental practitioners in Eastern France to maintain the water quality of their dental unit waterlines (DUWLs). A questionnaire about water quality maintenance practices was sent to 870 dental offices in 2016. The questionnaires were completed by 153 dental offices, covering about 223 dental care units. The majority of units were fed by mains water (91.0%), which is generally unfiltered (71.3%). One-third (33.6%) of the units had an independent water bottle reservoir. Flushing, a basic physical technique to improve the quality of units' outflow water, was practiced in 65.4% of dental offices. Concerning the chemical treatment of water, it was used for 62.1% of the units. An analysis of the microbiological quality of the DUWL water was only carried out in 2.6% of the offices. In conclusion, providing better training to dental staff seems necessary to improve their practices and to generalize procedures that improve the microbiological quality of the water used.
Collapse
Affiliation(s)
- Alexandre Baudet
- Faculty of Dentistry, University of Lorraine, 54505 Vandœuvre-lès-Nancy, France.
- Department of Dentistry, University Hospital, 54000 Nancy, France.
| | - Julie Lizon
- Department of Hygiene and Environmental Analysis, University Hospital, 54505 Vandœuvre-lès-Nancy, France.
| | - Jean-Marc Martrette
- Faculty of Dentistry, University of Lorraine, 54505 Vandœuvre-lès-Nancy, France.
- Department of Dentistry, University Hospital, 54000 Nancy, France.
- EA 3450 DevAH, University of Lorraine, 54505 Vandœuvre-lès-Nancy, France.
| | | | - Arnaud Florentin
- Department of Hygiene and Environmental Analysis, University Hospital, 54505 Vandœuvre-lès-Nancy, France.
- Faculty of Medicine, University of Lorraine, 54505 Vandœuvre-lès-Nancy, France.
- EA 4360 APEMAC, University of Lorraine, 54505 Vandœuvre-lès-Nancy, France.
| | - Céline Clément
- Faculty of Dentistry, University of Lorraine, 54505 Vandœuvre-lès-Nancy, France.
- Department of Dentistry, University Hospital, 54000 Nancy, France.
| |
Collapse
|
29
|
Okubo K, Ito T, Shiota Y, Kawata Y, Yamamoto T, Takashiba S. Effectiveness and safety of low-concentrated ozonized water for the reduction of contamination in dental unit water lines. Heliyon 2019; 5:e02306. [PMID: 31463403 PMCID: PMC6710486 DOI: 10.1016/j.heliyon.2019.e02306] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Revised: 05/09/2019] [Accepted: 08/09/2019] [Indexed: 11/30/2022] Open
Abstract
Contamination of dental unit waterlines (DUWL) with heterotrophic bacteria can cause problems in immune compromised patients (aged, tumor and organ transplantation-patients). We focused on the use of low-concentrated ozonized water (OZW) as the biofilm formation restraint system for DUWL. Here, we examined the effects of low-concentrated OZW on the growth of bacteria and related biofilm formation and harmfulness to dental unit components (DUCs) in vitro. OBJECTIVES To evaluate the bactericidal effects of OZW on biofilms in DUWL and DUC in vitro. METHODS Low-concentrated OZW (0.4 mg/L) was generated using an OZS-PTDX generator. Heterotrophic bacterial biofilms in old DUWL tubes and Candia albicans solution (control microbe) were treated with OZW for 1 h with gentle agitation before static culturing for 96 h in Reasoner's 2A liquid media. The control solutions were 0.1% cetylpyridinium chloride (CPC), chlorinated tap water (TW), and phosphate-buffered saline (PBS). Adenosine triphosphate (ATP) amounts of the microbes were measured and the biofilms of these microbes were observed using scanning electron microscopy (SEM). Moreover, surfaces of DUC soaked in OZW and TW were observed by SEM. RESULTS The OZW reduced ATP levels in microbes to 50% compared to TW and PBS treatment, although CPC reduced it below detection limits. SEM observation revealed deformation of microbes cultured with OZW, whereas no changes were seen on DUC surfaces. CONCLUSIONS Low-concentrated OZW is bactericidal against heterotrophic bacteria biofilms and it is not harmful to DUC, suggesting that it might be useful in preventing DUWL contamination.
Collapse
Affiliation(s)
- Keisuke Okubo
- Department of Pathophysiology - Periodontal Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8525, Japan
- Division of Dentistry, Tottori Municipal Hospital, 1-1 Matoba, Tottori, 680-8501, Japan
| | - Takashi Ito
- Center for Innovative Clinical Medicine, Okayama University Hospital, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8525, Japan
| | - Yasuyoshi Shiota
- Department of Pathophysiology - Periodontal Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8525, Japan
- Division of Dentistry, National Hospital Organization Shikoku Cancer Center, 160 Minamiumemoto-cho-ko, Matuyama, 791-0280, Japan
| | - Yusuke Kawata
- Department of Pathophysiology - Periodontal Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8525, Japan
| | - Tadashi Yamamoto
- Department of Pathophysiology - Periodontal Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8525, Japan
| | - Shogo Takashiba
- Department of Pathophysiology - Periodontal Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8525, Japan
| |
Collapse
|
30
|
Plasma Sterilization Effectively Reduces Bacterial Contamination in Dental Unit Waterlines. Int J Dent 2019; 2019:5720204. [PMID: 31467546 PMCID: PMC6701304 DOI: 10.1155/2019/5720204] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 07/01/2019] [Accepted: 07/14/2019] [Indexed: 12/27/2022] Open
Abstract
Objective To investigate the effectiveness of plasma sterilization in reducing bacterial contamination and controlling biofilms in dental unit waterlines. Materials and Methods Ten identical dental chair units (DCUs) were used. Five DCUs were installed with an automated plasma sterilization system (PSS) and the other five were kept as nontreated controls (CTL). Water flushed from the airotor line served as the output water of the dental unit waterlines (DUWLs). Water samples were collected at the beginning and on a weekly basis for 4 months. Water was analyzed for bacterial contamination (CFU/mL). Scanning electron microscopy (SEM) was used to investigate the amount of biofilm in the waterlines. Biofilm viability was assessed by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) assays. All statistical analyses were performed using the Mann-Whitney U test. A value of p < 0.05 was considered significant. Results The DCU output water was found to be heavily contaminated with bacteria. Plasma sterilization effectively reduced bacterial contamination from an average of 212 CFU/mL to 8 CFU/mL. During the entire period of 4 months, the level remained below 500 CFU/mL, the standard level recommended by the Centers for Disease Control and Prevention (CDC) of the USA. The reduction in the bacterial count was significant compared with the CTL group (p < 0.05). Plasma sterilization could not eradicate the existing biofilms in the waterlines, and it did reduce biofilm mass and viability. Moreover, treatment with plasma sterilization did not induce a change in the composition of microorganisms, as analyzed by Gram staining. Conclusion Plasma sterilization, which is part of electrochemically activated water, effectively reduces bacterial contamination and reduces biofilms in dental unit waterlines.
Collapse
|
31
|
Spagnolo AM, Sartini M, Cave DD, Casini B, Tuvo B, Cristina ML. Evaluation of Microbiological and Free-Living Protozoa Contamination in Dental Unit Waterlines. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:ijerph16152648. [PMID: 31344972 PMCID: PMC6696308 DOI: 10.3390/ijerph16152648] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Revised: 07/19/2019] [Accepted: 07/22/2019] [Indexed: 12/12/2022]
Abstract
Studies conducted over the last 40 years have demonstrated that the water output from dental unit waterlines (DUWLs) is often contaminated with high densities of microorganisms. It has been monitored the microbiological quality of the water in 30 public dental facilities in northern Italy in order to assess the health risk for patients and dental staff. In each facility, samples of water both from taps and from DUWLs were analyzed in order to evaluate heterotrophic plate counts (HPCs) at 22 °C and 36 °C, and to detect coliform bacteria, Pseudomonas aeruginosa, Legionella pneumophila and amoebae. In 100% of the samples taken from the DUWLs, the concentration of HPCs was above the threshold as determined by the Ministère de la Santé et des Solidarités (2007). The concentration of P. aeruginosa was greater than the indicated threshold in 16.67% of the hand-pieces analyzed. A total of 78.33% of samples were contaminated by L. pneumophila, while in the samples taken from the DUWLs alone, this percentage rose to 86.67%. Amoebae were detected in 60% of the samples taken from hand-pieces; all belonging to the species V. vermiformis. This study documented the presence of various microorganisms, including Legionella spp., at considerably higher concentrations in water samples from DUWLs than in samples of tap water in the same facilities, confirming the role of the internal DUWLs in increasing microbial contamination, especially in the absence of proper management of waterborne health risks.
Collapse
Affiliation(s)
- Anna Maria Spagnolo
- Department of Health Sciences, University of Genova, Via Pastore 1, 16132 Genova, Italy
| | - Marina Sartini
- Department of Health Sciences, University of Genova, Via Pastore 1, 16132 Genova, Italy.
| | - David Di Cave
- Department of Clinical Sciences and Translational Medicine, University of Rome Tor Vergata, 00133 Rome, Italy
| | - Beatrice Casini
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Benedetta Tuvo
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Maria Luisa Cristina
- Department of Health Sciences, University of Genova, Via Pastore 1, 16132 Genova, Italy
| |
Collapse
|
32
|
Gawish S, Abbass A, Abaza A. Occurrence and biofilm forming ability of Pseudomonas aeruginosa in the water output of dental unit waterlines in a dental center in Alexandria, Egypt. Germs 2019; 9:71-80. [PMID: 31341834 DOI: 10.18683/germs.2019.1160] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Revised: 05/13/2019] [Accepted: 05/23/2019] [Indexed: 11/08/2022]
Abstract
Introduction Dental unit waterlines (DUWLs) are notorious for being contaminated with different bacterial species including the opportunistic pathogen Pseudomonas aeruginosa which poses a risk to patients and professionals. This work aimed at studying the occurrence and biofilm-forming ability (BFA) of P. aeruginosa in the output of DUWLs in a dental center in Egypt. Methods Water samples were collected from the outlets of the high-speed hand piece, the air/water syringe and the cup filler waterlines. Bacteriological analysis included heterotrophic plate count (HPC), isolation and identification of P. aeruginosa and determination of the antimicrobial susceptibility and the BFA of the isolates by tissue culture plate (TCP) method and tube method (TM). Results The average concentration of HPC bacteria in the output of the 3 DUWLs was 2.9×104 CFU/μL where 88.3% of the samples exceeded the Egyptian standards for drinking water (<50 CFU L). P. aeruginosa was isolated from nine cup filler samples (which had a water source different from the other waterlines). The isolates were sensitive to all tested antimicrobials. Of these nine isolates, 6, 5 and 4 were positive for BFA by TCP, modified TCP and TM, respectively. Conclusions More stringent measures are required to ensure safer dental water; as the majority of studied samples exceeded the required HPC bacterial limit and P. aeruginosa isolates were detected. P. aeruginosa isolates from DUWLs may not be as resistant to antibiotics as what is reported in the literature about clinical isolates. Some P. aeruginosa isolates can colonize DUWLs despite their inability to form biofilms in experimental testing.
Collapse
Affiliation(s)
- Sheref Gawish
- MSc Microbiology, Microbiology Department, High Institute of Public Health, Alexandria University, 165 El Horreya Avenue, Alexandria, Egypt
| | - Aleya Abbass
- PhD, Professor of Microbiology, Microbiology Department, High Institute of Public Health, Alexandria University, 165 El Horreya Avenue, Alexandria, Egypt
| | - Amani Abaza
- PhD, Professor of Microbiology, Microbiology Department, High Institute of Public Health, Alexandria University, 165 El Horreya Avenue, Alexandria, Egypt
| |
Collapse
|
33
|
Lizzadro J, Mazzotta M, Girolamini L, Dormi A, Pellati T, Cristino S. Comparison between Two Types of Dental Unit Waterlines: How Evaluation of Microbiological Contamination Can Support Risk Containment. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:E328. [PMID: 30682855 PMCID: PMC6388184 DOI: 10.3390/ijerph16030328] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Revised: 01/16/2019] [Accepted: 01/18/2019] [Indexed: 01/16/2023]
Abstract
Infection risk management in a dental unit waterline (DUWL) involves healthcare personnel and patients and is related to routine exposure to water and aerosols that may contain bacterial species. To improve water safety plans, maintenance, and sanitation procedures, analyses of heterotrophic plate counts (HPCs) at 36 °C, and two other microorganisms frequently associated with biofilms, Pseudomonas aeruginosa and Legionella spp., were performed in order to evaluate differences in microbiological contamination between two types of DUWLs: Type A, provided by a water tank, and Type B, directly connected to municipal water. The data showed that the water supply and water safety plan differentially influenced microbiological contamination: Type A DUWLs were more contaminated than Type B DUWLs for all microbiological parameters tested, with significant changes in the percentage of positive samples and contamination levels that were beyond the limits of standard guidelines. The results obtained show how the storage tank, the absence of anti-retraction valves, and the disinfection procedures performed are the main critical points of Type A DUWLs, which confirms that dental unit management (maintenance/sanitization) is often missed or not correctly applied by stakeholders, with an underestimation of the real risk of infection for patients and operators.
Collapse
Affiliation(s)
- Jessica Lizzadro
- Department of Biological, Geological, and Environmental Sciences, BiGeA, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy.
| | - Marta Mazzotta
- Department of Biological, Geological, and Environmental Sciences, BiGeA, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy.
| | - Luna Girolamini
- Department of Biological, Geological, and Environmental Sciences, BiGeA, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy.
| | - Ada Dormi
- Department of Medical and Surgical Science, DIMEC, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy.
| | - Tiziana Pellati
- GVM Care & Research, via Emaldi 10, 48124 Lugo di Ravenna, Italy.
| | - Sandra Cristino
- Department of Biological, Geological, and Environmental Sciences, BiGeA, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy.
| |
Collapse
|
34
|
Ji XY, Fei CN, Zhang Y, Liu J, Liu H, Song J. Three key factors influencing the bacterial contamination of dental unit waterlines: a 6-year survey from 2012 to 2017. Int Dent J 2018; 69:192-199. [PMID: 30565215 DOI: 10.1111/idj.12456] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
BACKGROUND The contaminated output water from dental unit waterlines (DUWLs) is a potential risk to both patients and dental personnel who are frequently exposed to this water or aerosols. AIM The purpose was to evaluate the contamination level and prevalence of bacteria in the output water of DUWLs, and to identify key factors to provide technical support for formulating relevant policies. METHODS We developed a special sampling connector designed for collecting dental handpiece output water and a measurement device to assess retraction of a dental chair unit (DCU). Output water from dental handpieces and air/water syringes were collected as representative of DUWLs. Water samples were tested with reference to China's national standard. FINDINGS From 2012 to 2017, 318 DCUs were randomly selected from 64 hospitals in Tianjin, China. Of these DCUs, 78.93% had no disinfection to prevent DUWL contamination. Three-hundred and forty-three (56.14%) samples complied with the guidelines on DUWL output water. The highest concentration of bacteria was 1.8 × 106 colony-forming units (CFUs)/mL. The three key factors of influence were as follows: daily or weekly disinfection of DUWLs; water supply source being hospital self-made purified water or purchased purified bottled water; and DCU with a valid anti-retraction valve. Potential infectious agents, including Bacillus cereus, Burkholderia cepacia and Pseudomonas aeruginosa, were isolated. CONCLUSION There was a high rate of contamination in DUWLs. This highlights the need to develop national standards. There is a need to disinfect the DUWLs periodically and use a cleaner source of water; more attention should be paid to the efficacy of DCU anti-retraction valves.
Collapse
Affiliation(s)
- Xue-Yue Ji
- Department of Infectious Disease, Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - Chun-Nan Fei
- Department of Infectious Disease, Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - Ying Zhang
- Department of Infectious Disease, Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - Jun Liu
- Department of Infectious Disease, Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - He Liu
- Department of Infectious Disease, Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - Jia Song
- Department of Infectious Disease, Tianjin Centers for Disease Control and Prevention, Tianjin, China
| |
Collapse
|
35
|
Microbiologic assessment of flexible gastrointestinal endoscope reprocessing using a pump-assisted sampling technique: an investigation involving all endoscopy units in Tianjin, China. Am J Infect Control 2018; 46:e43-e48. [PMID: 29778431 DOI: 10.1016/j.ajic.2018.04.216] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Revised: 04/13/2018] [Accepted: 04/14/2018] [Indexed: 11/20/2022]
Abstract
BACKGROUND Microbiologic surveillance of flexible gastrointestinal endoscopes is recommended in several guidelines as the primary means of identifying reprocessing failures. This study aimed to evaluate the contamination level and prevalence of bacteria of post-reprocessing endoscopes and to access whether using a pump-assisted sampling method (PASM) improves the sensitivity of culture. METHODS All 59 endoscopy units in Tianjin, China, were investigated. The PASM and the conventional flushing sampling method (CFSM) were used to compare the results of the microbial culture. Logistic regression analysis was used to identify the influencing factors. RESULTS One hundred four (56.52%) flushing channel samples of gastrointestinal endoscopes were positive for culture, and the maximum bacterial concentration was 14,100 colony-forming units (CFU)/channel. One hundred fifty-one (82.07%) flushing samples were qualified according to the national standard of China (≤ 20 CFU/channel). The qualified rate of the samples collected by PASM was significantly lower than the qualified rate by CFSM (65.52% vs 89.68%). Using PASM (odds ratio [OR]: 4.257; 95% confidence interval [CI]: 1.870-9.690) would increase the sensitivity of culture. The use of purified water (OR: 0.288; 95% CI: 0.102-0.814) could reduce the risk of endoscope reprocessing failure. CONCLUSION Many endoscopes fail to meet the national standard for microbial culture after reprocessing. Our results suggest that using a pump-assisted method could increase the sensitivity of the test.
Collapse
|
36
|
Application of D-Amino Acids as Biofilm Dispersing Agent in Dental Unit Waterlines. Int J Dent 2018; 2018:9413925. [PMID: 29593796 PMCID: PMC5821966 DOI: 10.1155/2018/9413925] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Revised: 10/31/2017] [Accepted: 11/19/2017] [Indexed: 02/02/2023] Open
Abstract
Aim and Purpose Biofilms in dental unit waterlines (DUWLs) are extremely difficult to eliminate. Aim of this study is to evaluate the efficacy of a mixture of four D-amino acids on biofilm dispersion in DUWLs. Materials and Methods A mixture of four D-amino acids (D-methionine, D-tryptophan, D-leucine, and D-tyrosine, 10 mM each), distilled water (control), and 0.1 M hydrochloric acid (HCl) was used in the experiment. In laboratory, pieces of DUWLs covered with biofilms were submerged in different solutions for 5 days, flushed, and measured OD600 of the dispersed biofilms. Remnants of biofilms on the DUWLs were evaluated by SEM. In clinic, fifteen DCUs were incubated with test and control solutions, flushed, and measured OD600 of the dispersed biofilms. Microbial count of DUWL output water was enumerated twice a week for four weeks. Results There was a slight, but not significant, increase in OD600 of flushing water in D-amino acids group. D-amino acids effectively reduced bacterial plaque as demonstrated by SEM. Incubation with D-amino acids significantly reduced biofilms especially after the first day of flushing. Bacterial count in DUWL output water was significantly reduced after treatment with D-amino acids. Conclusion D-amino acids are applicable as biofilm dispersing agents in DUWLs.
Collapse
|
37
|
Yoon HY, Lee SY. Susceptibility of bacteria isolated from dental unit waterlines to disinfecting chemical agents. J GEN APPL MICROBIOL 2018; 64:269-275. [DOI: 10.2323/jgam.2018.02.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- Hye Young Yoon
- Department of Oral Microbiology, College of Dentistry, Research Institute of Oral Science, Gangneung-Wonju National University
| | - Si Young Lee
- Department of Oral Microbiology, College of Dentistry, Research Institute of Oral Science, Gangneung-Wonju National University
| |
Collapse
|
38
|
Lauritano D, Nardone M, Gaudio RM, Candotto V, Carinci F. Risk assessment of colonization of legionella spp. in dental unit waterlines. ACTA ACUST UNITED AC 2017; 10:283-288. [PMID: 29285331 DOI: 10.11138/orl/2017.10.3.283] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The aerosol produced during the use of dental instruments can spread pathogens potentially harmful to health. Most of the pathogens found in hydraulic system are Gram-negative aerobic heterotrophic environmental bacterial species exhibiting very low pathogenicity, although they may be of concern in the treatment of vulnerable patients, such as immunocompromised, medically compromised individuals and dental team. Dental team can be exposed to pathogenic microorganisms including cytomegalovirus, hepatitis B virus, hepatitis C virus, herpes simplex virus and Legionella spp. Legionella spp. are ubiquitous in hydraulic system, in fact surveys have shown that the percentage of samples taken at different dental chairs that were positive for Legionella spp. and ranged from 0 to 100%. The concentration of Legionella spp. in hydraulic system may reach 1000 organisms per ml. The primary route of Legionella spp. transmission is inhalation or aspiration of environmentally contaminated aerosols. All dentists are required to conduct a statutory risk assessment of their hydraulic system, in fact to comply with their legal duties, dentists must identify and assess the sources of risk and prepare a scheme for preventing and controlling risks. Moreover, they must monitor the quality of their hydraulic system at least annually to ensure that they are "legionellae free".
Collapse
Affiliation(s)
- D Lauritano
- Department of Medicine and Surgery, University of Milan-Bicocca, Monza, Italy
| | - M Nardone
- Ministry of Public Health, Rome, Italy
| | - R M Gaudio
- Department of Medical Sciences, University of Ferrara, Ferrara, Italy
| | - V Candotto
- Department of Morphology, Surgery and Experimental Medicine, University of Ferrara, Ferrara, Italy
| | - F Carinci
- Department of Morphology, Surgery and Experimental Medicine, University of Ferrara, Ferrara, Italy
| |
Collapse
|
39
|
Costa D, Bossard V, Brunet K, Fradin B, Imbert C. Planktonic free-living amoebae susceptibility to dental unit waterlines disinfectants. Pathog Dis 2017; 75:4082732. [PMID: 28911034 DOI: 10.1093/femspd/ftx099] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2017] [Accepted: 08/10/2017] [Indexed: 12/17/2022] Open
Abstract
A high diversity of microorganisms is encountered inside dental unit waterlines (DUWL). Among those the presence of free-living amoebae (FLA) appears currently underestimated, although human infections may occur due to contact with FLA-contaminated water during dental cares. In order to limit microbial DUWL contamination, disinfectants are provided by dental unit manufacturer, however, with limited documentation on their activities against FLA. The aim of this study was to evaluate the efficiency of three commercial DUWL disinfectants: the Calbenium© (Airel, Champigny-sur-Marne, France), the Oxygenal 6© (Kavo, Biberach, Germany) and the Sterispray© (Gammasonic, Billom, France), against two FLA species, i.e. Acanthamoeba castellanii and Vermamoeba vermiformis alone or co-cultured with Pseudomonas aeruginosa and Candida albicans at concentrations ranging from 0% to 5% (v/v). Results showed varied efficacies of disinfectants: the Oxygenal 6© did not exhibit FLA killing activity, while the Sterispray© and the Calbenium© displayed concentration- and species-dependent activities with a maximum eradication rates of 100% and 86%, and 79% and 97% for A. castellani and V. vermiformis, respectively. None of the disinfectants were able to totally eradicate FLA at concentrations recommended by manufacturers. Present results highlight unsatisfactory anti-FLA activities of 3 DUWL disinfectant preparations advocating deeper investigation of antimicrobial spectra of commercial disinfectants in use for DUWL maintenance.
Collapse
Affiliation(s)
- Damien Costa
- UMR CNRS 7267, Laboratory of Ecology and Biology of Interactions, Faculty of Medecine and Pharmacy, University of Poitiers, Bat D1, 6 rue de la Milétrie, TSA 51115, 86073 Poitiers Cedex 9, France
| | - Valentin Bossard
- UMR CNRS 7267, Laboratory of Ecology and Biology of Interactions, Faculty of Medecine and Pharmacy, University of Poitiers, Bat D1, 6 rue de la Milétrie, TSA 51115, 86073 Poitiers Cedex 9, France
| | - Kévin Brunet
- UMR CNRS 7267, Laboratory of Ecology and Biology of Interactions, Faculty of Medecine and Pharmacy, University of Poitiers, Bat D1, 6 rue de la Milétrie, TSA 51115, 86073 Poitiers Cedex 9, France
| | - Benjamin Fradin
- UMR CNRS 7267, Laboratory of Ecology and Biology of Interactions, Faculty of Medecine and Pharmacy, University of Poitiers, Bat D1, 6 rue de la Milétrie, TSA 51115, 86073 Poitiers Cedex 9, France
| | - Christine Imbert
- UMR CNRS 7267, Laboratory of Ecology and Biology of Interactions, Faculty of Medecine and Pharmacy, University of Poitiers, Bat D1, 6 rue de la Milétrie, TSA 51115, 86073 Poitiers Cedex 9, France
| |
Collapse
|
40
|
Pankhurst CL, Scully C, Samaranayake L. Dental Unit Water Lines and their Disinfection and Management: A Review. ACTA ACUST UNITED AC 2017; 44:284-5, 289-92. [PMID: 29172350 DOI: 10.12968/denu.2017.44.4.284] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The perceived threat to public health from dental unit water line (DUWL) contamination comes from opportunistic and respiratory pathogens such as Legionella spp, Nontuberculous Mycobacteria (NTM) and pseudomonads. These organisms can grow and multiply in the DUWL biofilm to reach infective concentrations, with the potential for inhalation leading to respiratory infections or direct contamination of surgical wounds. In this paper we discuss current legislation and practical methods for delivering water within the DUWL that meets the standards for safety. Clinical relevance: Understanding the clinical relevance and methods for decontaminating DUWL is essential to create a safe working environment in dentistry.
Collapse
|
41
|
Yoon HY, Lee SY. Establishing a laboratory model of dental unit waterlines bacterial biofilms using a CDC biofilm reactor. BIOFOULING 2017; 33:917-926. [PMID: 29160100 DOI: 10.1080/08927014.2017.1391950] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Accepted: 10/06/2017] [Indexed: 06/07/2023]
Abstract
In this study, a laboratory model to reproduce dental unit waterline (DUWL) biofilms was developed using a CDC biofilm reactor (CBR). Bacteria obtained from DUWLs were filtered and cultured in Reasoner's 2A (R2A) for 10 days, and were subsequently stored at -70°C. This stock was cultivated on R2A in batch mode. After culturing for five days, the bacteria were inoculated into the CBR. Biofilms were grown on polyurethane tubing for four days. Biofilm accumulation and thickness was 1.3 × 105 CFU cm-2 and 10-14 μm respectively, after four days. Bacteria in the biofilms included cocci and rods of short and medium lengths. In addition, 38 bacterial genera were detected in biofilms. In this study, the suitability and reproducibility of the CBR model for DUWL biofilm formation were demonstrated. The model provides a foundation for the development of bacterial control methods for DUWLs.
Collapse
Affiliation(s)
- Hye Young Yoon
- a Department of Oral Microbiology, College of Dentistry, Research Institute of Oral Science , Gangneung-Wonju National University , Gangneung , Korea
| | - Si Young Lee
- a Department of Oral Microbiology, College of Dentistry, Research Institute of Oral Science , Gangneung-Wonju National University , Gangneung , Korea
| |
Collapse
|
42
|
Zhang Y, Ping Y, Zhou R, Wang J, Zhang G. High throughput sequencing-based analysis of microbial diversity in dental unit waterlines supports the importance of providing safe water for clinical use. J Infect Public Health 2017; 11:357-363. [PMID: 28988812 DOI: 10.1016/j.jiph.2017.09.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2017] [Revised: 09/02/2017] [Accepted: 09/09/2017] [Indexed: 01/27/2023] Open
Abstract
This study aims to explore the water quality of dental unit waterlines (DUWLs) and the diversity of microbial communities in DUWLs. Water samples from 33 dental chair units (DCUs) were collected, diluted and then spread on sterilized R2A plate for incubation. Subsequently, the microbial colony-forming units per milliliter (CFU/ml) were recorded by an automatic colony analyzer. Total DNA extracted from the rest of the samples was tested on the Illumina MiSeq PE300 platform. T-test and Kruskal-Wallis rank test were adopted for statistical analysis. Significance was assumed at a P<0.05. After incubation, the average total microbial count was 21,413.13±17,861.00CFU/ml. High-throughput sequencing revealed 10 bacterial phyla, including 9 identified and 1 unclassified phyla. Totally 63 sequences were identified at the genus level, including 42 genera, 3 tentative species and 18 unclassified genera. In addition, 7 potential human pathogenic bacteria were detected. In summary, department, brand and service life of DCUs do not influence the water quality of DUWLs significantly. The diversity of microbial communities in DUWLs is abundant and includes both pathogenic and some unknown bacteria.
Collapse
Affiliation(s)
- Yuan Zhang
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Yifan Ping
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Ruyu Zhou
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Juan Wang
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University, Department of Endodontics and Operative Dentistry, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, Jiangsu, China.
| | - Guangdong Zhang
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University, Department of Endodontics and Operative Dentistry, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, Jiangsu, China.
| |
Collapse
|
43
|
Petti S, Vitali M. Occupational risk for Legionella infection among dental healthcare workers: meta-analysis in occupational epidemiology. BMJ Open 2017; 7:e015374. [PMID: 28710211 PMCID: PMC5734417 DOI: 10.1136/bmjopen-2016-015374] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
OBJECTIVE The occupational risk for Legionella infection among dental healthcare workers (DHCWs) is conjectured because of the risk of routine inhalation of potentially contaminated aerosols produced by the dental instruments. Nevertheless, occupational epidemiology studies are contrasting. This meta-analysis assessed the level of scientific evidence regarding the relative occupational risk for Legionella infection among DHCWs. METHODS Literature search was performed without time and language restrictions, using broad data banks (PubMed, Scopus, Web of Science, GOOGLE Scholar) and generic keywords ('legionella' AND 'dent*'). Analytical cross-sectional studies comparing prevalence of high serum Legionella antibody levels in DHCWs and occupationally unexposed individuals were considered. The relative occupational risk was assessed through prevalence ratio (PR) with 95% CI. Between-study heterogeneity was assessed (Cochran's Q test) and was used to choose the meta-analytic method. Study quality (modified Newcastle-Ottawa Scale) and publication bias (Begg and Mazumdar's test, Egger and colleagues' test, trim and fill R0 method) were assessed formally and considered for the sensitivity analysis. Sensitivity analysis to study inclusion, subgroup analyses (dental staff categories; publication year, before vs after 1998, ie, 5 years after the release by the Centers for Disease Control and Prevention of the infection control guidelines in dental healthcare setting) were performed. RESULTS Seven studies were included (2232 DHCWs, 1172 occupationally unexposed individuals). No evidence of publication bias was detected. The pooled PR estimate was statistically non-significant at 95% level (1.7; 95% CI 0.8 to 3.2), study-quality adjustment did not change the PR considerably (PR, 1.5; 95% CI 0.5 to 4.1). PR was statistically significant before 1998 and no longer significant after 1998. Subgroup analysis according to DHCW categories was inconclusive. CONCLUSIONS There is no scientific evidence that DHCWs are at high occupational risk. The differences between former and recent studies could be due to different characteristics of municipal water systems and the infection control guideline dissemination.
Collapse
Affiliation(s)
- Stefano Petti
- Department of Public Health and Infectious Diseases, Sapienza University of Rome, Rome, Italy
| | - Matteo Vitali
- Department of Public Health and Infectious Diseases, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
44
|
Rams TE, van Winkelhoff AJ. Introduction to Clinical Microbiology for the General Dentist. Dent Clin North Am 2017; 61:179-197. [PMID: 28317561 DOI: 10.1016/j.cden.2016.11.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Clinical oral microbiology may help dental professionals identify infecting pathogenic species and evaluate their in vitro antimicrobial susceptibility. Saliva, dental plaque biofilms, mucosal smears, abscess aspirates, and soft tissue biopsies are sources of microorganisms for laboratory testing. Microbial-based treatment end points may help clinicians better identify patients in need of additional or altered dental therapies before the onset of clinical treatment failure, and help improve patient oral health outcomes. Microbiological testing appears particularly helpful in periodontal disease treatment planning. Further research and technological advances are likely to increase the availability and clinical utility of microbiological analysis in modern dental practice.
Collapse
Affiliation(s)
- Thomas E Rams
- Department of Periodontology and Oral Implantology, Oral Microbiology Testing Service Laboratory, Temple University School of Dentistry, 3223 North Broad Street, Philadelphia, PA 19140, USA; Department of Microbiology and Immunology, Temple University School of Medicine, 3500 North Broad Street, Philadelphia, PA 19140, USA.
| | - Arie J van Winkelhoff
- Center for Dentistry and Oral Hygiene, University Medical Center Groningen, Faculty of Medical Sciences, University of Groningen, Antonius Deusinglaan 1, Groningen 9713 AV, The Netherlands; Department of Medical Microbiology, University Medical Center Groningen, Faculty of Medical Sciences, University of Groningen, Hanzeplein 1, Groningen GZ 9713, The Netherlands
| |
Collapse
|
45
|
Cataldi ME, Al Rakayan S, Arcuri C, Condò R. Dental unit wastewater, a current environmental problem: a sistematic review. ORAL & IMPLANTOLOGY 2017; 10:354-359. [PMID: 29682252 DOI: 10.11138/orl/2017.10.4.354] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The dental unit waters are divided in two different groups, because of their chemical and microbial composition proprieties: in the first there is the "incoming dental unit water", drinking water that arrived directly in the dental chair unit through the municipal water system; in the second there is the "waste water", that represents the whole dental unit waste water. Regarding the lack of a complete systematic review on the quality of dental unit wastewater, the aim of the current research was to systematically study the incoming dental unit water and the waste one, focusing the attention on the problem of the wastewater contamination and its regulations. Materials and methods A systematic literature review of the last 17 years was conducted on the topic of dental unit wastewater. Italian and English were the languages chosen for the papers research.Studies were searched in PubMed, Medline and Cochrane, with regard to inclusion criteria. Results The investigation and analysis of the two papers group revealed the presence of many information and scientific studies on the incoming dental unit water contamination, in contrast not much in literature about dental unit waste-water. Conclusions The results revealed that dental unit wastewater is a problem underestimated by the scientific community, with the exception of dental amalgam wastes.In Italy there is a sentence of "Corte di Cassazione Penale, sez III, sentenza 17 gennaio 2013, n 2340" that regularized dental wastewaters as industrial ones, so they are inadequate to be disposed as domestic waters; but, at the same time, there isn't a specific law that regulates this king of waste.
Collapse
Affiliation(s)
- M E Cataldi
- PhD in Materials for Health, Environment and Energy, Department of Clinical Sciences and Translational Medicine, University of Rome "Tor Vergata", Rome, Italy
| | - S Al Rakayan
- PhD in Materials for Health, Environment and Energy, Department of Clinical Sciences and Translational Medicine, University of Rome "Tor Vergata", Rome, Italy
| | - C Arcuri
- Department of Clinical Sciences and Translational Medicine, University of Rome "Tor Vergata", Rome, Italy
| | - R Condò
- Department of Clinical Sciences and Translational Medicine, University of Rome "Tor Vergata", Rome, Italy
| |
Collapse
|
46
|
Costa D, Mercier A, Gravouil K, Lesobre J, Verdon J, Imbert C. Occurrence and diversity of both bacterial and fungal communities in dental unit waterlines subjected to disinfectants. Pathog Dis 2016; 74:ftw094. [PMID: 27630186 DOI: 10.1093/femspd/ftw094] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/09/2016] [Indexed: 11/13/2022] Open
Abstract
Chemical disinfectants are widely advocated to reduce the microbial contamination in dental unit waterlines (DUWL). However, until now their efficacy has been poorly examined after long-term application. In this study, through quantitative PCR and high-throughput sequencing, both bacterial and fungal communities were profiled from 8- to 12-year-old DUWL treated with disinfectants commonly used by European dentists. Water was collected from the tap water supplying units to the output exposure point of the turbine handpiece following a stagnation period and dental care activity. Results showed that (i) the unit itself is the principal source of microbial contamination and (ii) water stagnation, DU maintenance practices and quality of water supplying DU appeared as parameters driving the water quality. Despite disinfecting treatment combined to flushing process, the microbial contamination remained relevant in the studied output water, in association with a high bacterial and fungal diversity. The occurrence of potentially pathogenic microorganisms in these treated DUWL demonstrated a potential infectious risk for both patients and dental staff. A disinfectant shock before a prolonged stagnation period could limit the microbial proliferation inside DUWL. Necessity to proceed to regular water quality control of DUWL was highlighted.
Collapse
Affiliation(s)
- Damien Costa
- Team Water Microbiology, Ecology and Biology of Interactions, CNRS, University of Poitiers, 86073 Poitiers Cedex, France Bacteriology and Hospital Hygiene Laboratory, University Hospital of Poitiers 86021 Poitiers Cedex, France
| | - Anne Mercier
- Team Water Microbiology, Ecology and Biology of Interactions, CNRS, University of Poitiers, 86073 Poitiers Cedex, France Cooperative Laboratory Thanaplast SP-EBI-Carbios Bioplastics, Ecology and Biology of interactions, CNRS UMR 7267, University of Poitiers 86073 Poitiers Cedex, France
| | - Kevin Gravouil
- Cooperative Laboratory Thanaplast SP-EBI-Carbios Bioplastics, Ecology and Biology of interactions, CNRS UMR 7267, University of Poitiers 86073 Poitiers Cedex, France
| | - Jérôme Lesobre
- Microorganisms laboratory: Genome and environment, UMR CNRS 6023, University Blaise Pascal 63177 Aubière Cedex, France
| | - Julien Verdon
- Team Water Microbiology, Ecology and Biology of Interactions, CNRS, University of Poitiers, 86073 Poitiers Cedex, France
| | - Christine Imbert
- Team Water Microbiology, Ecology and Biology of Interactions, CNRS, University of Poitiers, 86073 Poitiers Cedex, France University of Medicine Pharmacy of Poitiers 86073 Poitiers Cedex, France
| |
Collapse
|
47
|
Watanabe A, Tamaki N, Yokota K, Matsuyama M, Kokeguchi S. Monitoring of bacterial contamination of dental unit water lines using adenosine triphosphate bioluminescence. J Hosp Infect 2016; 94:393-396. [PMID: 27597265 DOI: 10.1016/j.jhin.2016.08.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2016] [Accepted: 08/02/2016] [Indexed: 11/17/2022]
Abstract
Bacterial contamination of dental unit waterlines (DUWLs) was evaluated using ATP bioluminescence analysis and a conventional culture method. Water samples (N=44) from DUWLs were investigated for heterotrophic bacteria by culture on R2A agar, which gave counts ranging from 1.4×103 to 2.7×105 cfu/mL. The ATP bioluminescence results for DUWL samples ranged from 6 to 1189 relative light units and could be obtained within 1min; these correlated well with the culture results (r=0.727-0.855). We conclude that the results of the ATP bioluminescence assay accurately reflect the results of conventional culture-based testing. This method is potentially useful for rapid and simple monitoring of DUWL bacterial contamination.
Collapse
Affiliation(s)
- A Watanabe
- Department of Oral Health Care and Rehabilitation, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan.
| | - N Tamaki
- Department of Preventive Dentistry, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan
| | - K Yokota
- Graduate School of Health Sciences, Okayama University, Okayama, Japan
| | - M Matsuyama
- Department of Oral Health Care and Rehabilitation, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan
| | - S Kokeguchi
- Department of Oral Microbiology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
| |
Collapse
|
48
|
Ditommaso S, Giacomuzzi M, Ricciardi E, Zotti CM. Efficacy of a Low Dose of Hydrogen Peroxide (Peroxy Ag⁺) for Continuous Treatment of Dental Unit Water Lines: Challenge Test with Legionella pneumophila Serogroup 1 in a Simulated Dental Unit Waterline. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2016; 13:E745. [PMID: 27455299 PMCID: PMC4962286 DOI: 10.3390/ijerph13070745] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2016] [Revised: 07/11/2016] [Accepted: 07/19/2016] [Indexed: 11/29/2022]
Abstract
This study was designed to examine the in vitro bactericidal activity of hydrogen peroxide against Legionella. We tested hydrogen peroxide (Peroxy Ag⁺) at 600 ppm to evaluate Legionella survival in a simulated dental treatment water system equipped with Water Hygienization Equipment (W.H.E.) device that was artificially contaminated. When Legionella pneumophila serogroup (sg) 1 was exposed to Peroxy Ag⁺ for 60 min we obtained a two decimal log reduction. High antimicrobial efficacy was obtained with extended periods of exposure: four decimal log reduction at 75 min and five decimal log reduction at 15 h of exposure. Involving a simulation device (Peroxy Ag⁺ is flushed into the simulation dental unit waterlines (DUWL)) we obtained an average reduction of 85% of Legionella load. The product is effective in reducing the number of Legionella cells after 75 min of contact time (99.997%) in the simulator device under test conditions. The Peroxy Ag⁺ treatment is safe for continuous use in the dental water supply system (i.e., it is safe for patient contact), so it could be used as a preventive option, and it may be useful in long-term treatments, alone or coupled with a daily or periodic shock treatment.
Collapse
Affiliation(s)
- Savina Ditommaso
- Department of Public Health and Pediatrics, University of Turin, Turin 10126, Italy.
| | - Monica Giacomuzzi
- Department of Public Health and Pediatrics, University of Turin, Turin 10126, Italy.
| | - Elisa Ricciardi
- Department of Public Health and Pediatrics, University of Turin, Turin 10126, Italy.
| | - Carla M Zotti
- Department of Public Health and Pediatrics, University of Turin, Turin 10126, Italy.
| |
Collapse
|
49
|
Pawar A, Garg S, Mehta S, Dang R. Breaking the Chain of Infection: Dental Unit Water Quality Control. J Clin Diagn Res 2016; 10:ZC80-4. [PMID: 27630960 DOI: 10.7860/jcdr/2016/19070.8196] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Accepted: 05/26/2016] [Indexed: 11/24/2022]
Abstract
INTRODUCTION The air-water syringes, ultrasonic scalers, high speed air turbine handpieces are connected to dental units by a network of small-bore plastic tubes through which water and air travel to activate or cool the instruments and it had been shown that this system is extensively contaminated with microbial biofilms and pose a potential risk of infection for patients as well as dental professionals. AIM To evaluate and compare the efficacy of various disinfectants in reducing the microbial colony count in water derived from Dental Unit Waterlines. MATERIALS AND METHODS Five random dental units were selected and samples were collected before and after intervention with 5 disinfectants (0.02% H2O2 continuously, 0.02% H2O2 continuously with shock treatment with 0.25% H2O2 weekly, 0.12% Chlorohexidine and 12% Ethanol overnight, 1:50 Original Listerine overnight, 2% Sodium Perborate and 2% EDTA 5 minutes in morning) using different disinfection methods for 4 weeks. Samples were cultured on Reasoner's 2A (R2A) agar for microbial counting. RESULTS Results were recorded as Colony forming units/ml (cfu/ml) and were evaluated statistically. Results showed that all the dental unit waterlines were heavily contaminated with microbes before any intervention. After 1 day of disinfection regime the counts reduced significantly and showed progressive reduction in consecutive weeks. Goals set by ADA & CDC were ultimately achieved at the end of 4 weeks. CONCLUSION All the disinfectants were equally effective in reducing the microbial colony count of DUWLs, irrespective of their concentration and method of disinfection.
Collapse
Affiliation(s)
- Amrita Pawar
- Senior Lecturer, Department of Prosthodontics, ITS College of Dental Sciences & Research , Muradnagar, Ghaziabad, UP, India
| | - Sandeep Garg
- Professor and Head, Department of Prosthodontics, MM College of Dental Sciences & Research , Mullana, Ambala, Haryana, India
| | - Sonia Mehta
- Associate Professor, Department of Microbiology, MM College of Medical Sciences & Research , Mullana, Ambala, Haryana, India
| | - Rajat Dang
- Professor, Department of Prosthodontics, MM College of Dental Sciences & Research , Mullana, Ambala, Haryana, India
| |
Collapse
|
50
|
Ji XY, Fei CN, Zhang Y, Zhang W, Liu J, Dong J. Evaluation of bacterial contamination of dental unit waterlines and use of a newly designed measurement device to assess retraction of a dental chair unit. Int Dent J 2016; 66:208-14. [PMID: 27000421 DOI: 10.1111/idj.12225] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
INTRODUCTION Dental unit waterline (DUWL) output water is delivered through instruments of a dental chair unit (DCU) to irrigate and cool teeth. However, these waterlines can be heavily contaminated with bacteria. AIM The purpose of the present study was to assess retraction and investigate the contamination level and prevalence of bacteria in DUWL output water. METHODS Fifty-eight DCUs were randomly selected from 30 hospitals in 10 districts of Tianjin, one of the four special municipalities of China. A unique sampling connector was used in place of the dental handpiece to collect water samples. Evaluation of retraction was accomplished using a retraction measurement device designed in accordance with the International Standard ISO 7494-2:2015(E). RESULTS A total of 263 water samples were collected, and the highest concentration of bacteria [1.8 × 10(6) colony-forming units (CFU)/mL] was found in the handpiece group. Thirty (51.72%) water samples in the handpiece group and 21 (36.21%) in the air/water syringe groups were cultured, yielding colony counts of > 500 CFU/mL. Potential infectious agents, such as Bacillus cereus, Kocuria kristinae and Pseudomonas fluorescens, were isolated from the water samples. Thirty (51.72%) DCUs failed the retraction evaluation. There was a significant, positive correlation (P < 0.05) between the concentration of bacteria in the water sample and the retracted volume. CONCLUSION It is of paramount importance to increase compliance with the standards for controlling DUWL contamination. Routine microbial monitoring and evaluation of retraction are necessary to provide high-quality water for use in dental treatment.
Collapse
Affiliation(s)
- Xue-Yue Ji
- Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - Chun-Nan Fei
- Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - Ying Zhang
- Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - Wei Zhang
- Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - Jun Liu
- Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - Jie Dong
- Tianjin Centers for Disease Control and Prevention, Tianjin, China
| |
Collapse
|