1
|
Huang Z, Meng L, Bi X, Xie Z, Liang W, Huang J. Efficacy and safety of robot-assisted deep brain stimulation for Parkinson's disease: a meta-analysis. Front Aging Neurosci 2024; 16:1419152. [PMID: 38882524 PMCID: PMC11176545 DOI: 10.3389/fnagi.2024.1419152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Accepted: 05/20/2024] [Indexed: 06/18/2024] Open
Abstract
Objective This meta-analysis aims to assess the effectiveness and safety of robot-assisted deep brain stimulation (DBS) surgery for Parkinson's disease(PD). Methods Four databases (Medline, Embase, Web of Science and CENTRAL) were searched from establishment of database to 23 March 2024, for articles studying robot-assisted DBS in patients diagnosed with PD. Meta-analyses of vector error, complication rate, levodopa-equivalent daily dose (LEDD), Unified Parkinson's Disease Rating Scale (UPDRS), UPDRS II, UPDRS III, and UPDRS IV were performed. Results A total of 15 studies were included in this meta-analysis, comprising 732 patients with PD who received robot-assisted DBS. The pooled results revealed that the vector error was measured at 1.09 mm (95% CI: 0.87 to 1.30) in patients with Parkinson's disease who received robot-assisted DBS. The complication rate was 0.12 (95% CI, 0.03 to 0.24). The reduction in LEDD was 422.31 mg (95% CI: 68.69 to 775.94). The improvement in UPDRS, UPDRS III, and UPDRS IV was 27.36 (95% CI: 8.57 to 46.15), 14.09 (95% CI: 4.67 to 23.52), and 3.54 (95% CI: -2.35 to 9.43), respectively. Conclusion Robot-assisted DBS is a reliable and safe approach for treating PD. Robot-assisted DBS provides enhanced accuracy in contrast to conventional frame-based stereotactic techniques. Nevertheless, further investigation is necessary to validate the advantages of robot-assisted DBS in terms of enhancing motor function and decreasing the need for antiparkinsonian medications, in comparison to traditional frame-based stereotactic techniques.Clinical trial registration: PROSPERO(CRD42024529976).
Collapse
Affiliation(s)
- Zhilong Huang
- The First Affiliated Hospital of Guangxi University of Science and Technology, Guangxi University of Science and Technology, Liuzhou, Guangxi, China
| | - Lian Meng
- The First Affiliated Hospital of Guangxi University of Science and Technology, Guangxi University of Science and Technology, Liuzhou, Guangxi, China
| | - Xiongjie Bi
- The First Affiliated Hospital of Guangxi University of Science and Technology, Guangxi University of Science and Technology, Liuzhou, Guangxi, China
| | - Zhengde Xie
- The First Affiliated Hospital of Guangxi University of Science and Technology, Guangxi University of Science and Technology, Liuzhou, Guangxi, China
| | - Weiming Liang
- The First Affiliated Hospital of Guangxi University of Science and Technology, Guangxi University of Science and Technology, Liuzhou, Guangxi, China
| | - Jinyu Huang
- The First Affiliated Hospital of Guangxi University of Science and Technology, Guangxi University of Science and Technology, Liuzhou, Guangxi, China
| |
Collapse
|
2
|
Gunderman AL, Sengupta S, Huang Z, Sigounas D, Oluigbo C, Godage IS, Cleary K, Chen Y. Towards MR-Guided Robotic Intracerebral Hemorrhage Evacuation: Aiming Device Design and ex vivo Ovine Head Trial. IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS 2024; 6:577-588. [PMID: 38911181 PMCID: PMC11189651 DOI: 10.1109/tmrb.2024.3385794] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/25/2024]
Abstract
Stereotactic neurosurgery is a well-established surgical technique for navigation and guidance during treatment of intracranial pathologies. Intracerebral hemorrhage (ICH) is an example of various neurosurgical conditions that can benefit from stereotactic neurosurgery. As a part of our ongoing work toward real-time MR-guided ICH evacuation, we aim to address an unmet clinical need for a skull-mounted frameless stereotactic aiming device that can be used with minimally invasive robotic systems for MR-guided interventions. In this paper, we present NICE-Aiming, a Neurosurgical, Interventional, Configurable device for Effective-Aiming in MR-guided robotic neurosurgical interventions. A kinematic model was developed and the system was used with a concentric tube robot (CTR) for ICH evacuation in (i) a skull phantom and (ii) in the first ever reported ex vivo CTR ICH evacuation using an ex vivo ovine head. The NICE-Aiming prototype provided a tip accuracy of 1.41±0.35 mm in free-space. In the MR-guided gel phantom experiment, the targeting accuracy was 2.07±0.42 mm and the residual hematoma volume was 12.87 mL (24.32% of the original volume). In the MR-guided ex vivo ovine head experiment, the targeting accuracy was 2.48±0.48 mm and the residual hematoma volume was 1.42 mL (25.08% of the original volume).
Collapse
Affiliation(s)
- Anthony L Gunderman
- Department of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30338 USA
| | - Saikat Sengupta
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232 USA
| | - Zhefeng Huang
- Department of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30338 USA
| | - Dimitri Sigounas
- The George Washington University School of Medicine and Health Sciences, Department of Neurosurgery, The George Washington University, Washington, DC, US
| | - Chima Oluigbo
- Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Hospital, Washington, DC 20010 USA
| | - Isuru S Godage
- Department of Engineering Technology and Industrial Distribution, Texas A&M University, College Station, TX, USA
| | - Kevin Cleary
- Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Hospital, Washington, DC 20010 USA
| | - Yue Chen
- Biomedical Engineering Department, Georgia Institute of Technology/Emory, Atlanta 30338 USA
| |
Collapse
|
3
|
He Z, Dai J, Ho JD, Tong H, Wang X, Fang G, Liang L, Cheung C, Guo Z, Chang H, Iordachita I, Taylor RH, Poon W, Chan DT, Kwok K. Interactive Multi-Stage Robotic Positioner for Intra-Operative MRI-Guided Stereotactic Neurosurgery. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2305495. [PMID: 38072667 PMCID: PMC10870025 DOI: 10.1002/advs.202305495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 10/30/2023] [Indexed: 02/17/2024]
Abstract
Magnetic resonance imaging (MRI) demonstrates clear advantages over other imaging modalities in neurosurgery with its ability to delineate critical neurovascular structures and cancerous tissue in high-resolution 3D anatomical roadmaps. However, its application has been limited to interventions performed based on static pre/post-operative imaging, where errors accrue from stereotactic frame setup, image registration, and brain shift. To leverage the powerful intra-operative functions of MRI, e.g., instrument tracking, monitoring of physiological changes and tissue temperature in MRI-guided bilateral stereotactic neurosurgery, a multi-stage robotic positioner is proposed. The system positions cannula/needle instruments using a lightweight (203 g) and compact (Ø97 × 81 mm) skull-mounted structure that fits within most standard imaging head coils. With optimized design in soft robotics, the system operates in two stages: i) manual coarse adjustment performed interactively by the surgeon (workspace of ±30°), ii) automatic fine adjustment with precise (<0.2° orientation error), responsive (1.4 Hz bandwidth), and high-resolution (0.058°) soft robotic positioning. Orientation locking provides sufficient transmission stiffness (4.07 N/mm) for instrument advancement. The system's clinical workflow and accuracy is validated with lab-based (<0.8 mm) and MRI-based testing on skull phantoms (<1.7 mm) and a cadaver subject (<2.2 mm). Custom-made wireless omni-directional tracking markers facilitated robot registration under MRI.
Collapse
Affiliation(s)
- Zhuoliang He
- Department of Mechanical EngineeringThe University of Hong KongHong Kong999077China
| | - Jing Dai
- Department of Mechanical EngineeringThe University of Hong KongHong Kong999077China
| | - Justin Di‐Lang Ho
- Department of Mechanical EngineeringThe University of Hong KongHong Kong999077China
| | - Hon‐Sing Tong
- Department of Mechanical EngineeringThe University of Hong KongHong Kong999077China
| | - Xiaomei Wang
- Department of Mechanical EngineeringThe University of Hong KongHong Kong999077China
- Multi‐Scale Medical Robotics CenterHong Kong999077China
| | - Ge Fang
- Department of Mechanical EngineeringThe University of Hong KongHong Kong999077China
| | - Liyuan Liang
- Department of Biomedical EngineeringThe Chinese University of Hong KongHong Kong999077China
- Multi‐Scale Medical Robotics CenterHong Kong999077China
| | - Chim‐Lee Cheung
- Department of Mechanical EngineeringThe University of Hong KongHong Kong999077China
| | - Ziyan Guo
- Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonWC1E 6BTUK
- Wellcome/EPSRC Centre for Interventional and Surgical SciencesUniversity College LondonLondonWC1E 6BTUK
| | - Hing‐Chiu Chang
- Department of Biomedical EngineeringThe Chinese University of Hong KongHong Kong999077China
- Multi‐Scale Medical Robotics CenterHong Kong999077China
| | - Iulian Iordachita
- Department of Mechanical Engineering and Laboratory for Computational Sensing and RoboticsJohns Hopkins UniversityBaltimoreMD 21218USA
| | - Russell H. Taylor
- Department of Computer Science and Laboratory for Computational Sensing and RoboticsJohns Hopkins UniversityBaltimoreMD 21218USA
| | - Wai‐Sang Poon
- Division of NeurosurgeryDepartment of SurgeryPrince of Wales HospitalThe Chinese University of Hong KongHong Kong999077China
- Neuromedicine CenterShenzhen Hospital, The University of Hong KongShenzhen518053China
| | - Danny Tat‐Ming Chan
- Division of NeurosurgeryDepartment of SurgeryPrince of Wales HospitalThe Chinese University of Hong KongHong Kong999077China
- Multi‐Scale Medical Robotics CenterHong Kong999077China
| | - Ka‐Wai Kwok
- Department of Mechanical EngineeringThe University of Hong KongHong Kong999077China
- Multi‐Scale Medical Robotics CenterHong Kong999077China
| |
Collapse
|
4
|
Chuang TC, Tan JQ, Chen SM. Comparison of intraoperative imaging guided versus microelectrode recording guided deep brain stimulation for Parkinson's disease: A meta-analysis. NEUROCIRUGIA (ENGLISH EDITION) 2023; 34:228-237. [PMID: 36931932 DOI: 10.1016/j.neucie.2022.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Accepted: 09/12/2022] [Indexed: 03/17/2023]
Abstract
BACKGROUND Traditionally, most centers would use microelectrode recording (MER) to refine targeting in deep brain stimulation (DBS) surgery. In recent years, intraoperative imaging (IMG) guided DBS has become an alternative way to verify lead placement. Currently, there is still controversy surrounding the necessity of MER or IMG for DBS. This meta-analysis aims to explore lead accuracy, clinical efficacy and safety between IMG and MER guided DBS for Parkinson's disease (PD). METHODS PubMed, Embase, Web of Science, Cochrane Library were searched up to Mar, 2021 for studies reporting comparisons between IMG and MER guided DBS for PD. Subgroup analysis was conducted to assess effects of different IMG technology and DBS targeting site. RESULTS Six studies, comprising of 478 patients were included in our analysis. The mean difference between the two implantation techniques in stereotactic accuracy, lead passes per trajectory, improvement% of Unified Parkinson's Disease Rating Scale part III and levodopa equivalent daily dose were -0.45 (95% confidence interval, CI=-1.11 to 0.20), -0.18 (95% CI=-0.41 to 0.06), 3.40 (95% CI=-5.36 to 12.16), and 5.00 (95% CI=-1.40 to 11.39), respectively. No significant differences were observed in each adverse event and operation/procedure time between the two implantation techniques. CONCLUSIONS Both IMG and MER guided DBS offered effective control of motor symptoms for PD. Besides, IMG guided is comparable to MER guided DBS, in terms of safety, accuracy and efficiency. It is recommended for each hospital to select DBS guidance technology based on available resources and equipment.
Collapse
Affiliation(s)
- Tsung-Che Chuang
- Department of Primary Medicine, Shuang-Ho Hospital, New Taipei, Taiwan
| | - Jia-Qi Tan
- Department of Primary Medicine, Shuang-Ho Hospital, New Taipei, Taiwan
| | - Shu-Mei Chen
- Department of Surgery, School of Medicine, Taipei Medical University, Taipei, Taiwan; Department of Neurosurgery, Taipei Medical University Hospital, Taipei Medical University, Taipei, Taiwan.
| |
Collapse
|
5
|
Giordano U, Mizera J, Żak E, Pilch J, Tomecka P, Dudzik T, Palczewski M, Biziorek W, Piotrowski P. Surgical treatment methods in the course of psychiatric disorders: Deep brain stimulation-Novel insights and indications. Indian J Psychiatry 2023; 65:799-807. [PMID: 37736228 PMCID: PMC10510643 DOI: 10.4103/indianjpsychiatry.indianjpsychiatry_266_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Revised: 07/06/2023] [Accepted: 07/12/2023] [Indexed: 09/23/2023] Open
Abstract
Deep brain stimulation (DBS) is a relatively dated treatment procedure that emerged in the late 1980s. Nonetheless, numerous studies are being carried out to examine its influence on the human brain and develop new treatment indications. This systematic review aims to summarize the current state of knowledge referring to DBS, investigate novel insights into its indications, and discuss the technical aspects and rationale behind DBS application. In particular, we sought to subject to scrutiny the application of DBS specifically in anorexia nervosa (AN), various addiction types, depression, and obsessive-compulsive disorders (OCDs). The method is supposed to offer promising results, especially in pharmacologically resistant forms of the upper-mentioned psychiatric disorders. Moreover, further insight has been provided into the historical notions of the method and differences in the surgical approach in specific disease entities. Furthermore, we mark the possible influence of comorbidities on treatment results. Our review consists of articles and studies found on PubMed, Google Scholar, Cochrane, and Scopus, which were then analyzed with scrutiny in the identification process, including the most resourceful ones. After methodological quality and risk of bias assessment, a total of 53 studies were included. To this date, DBS's usefulness in the treatment of AN, OCDs, depression, and addictions has been proven, despite an ongoing debate concerning the technical aspects and parameters when applying DBS. To the best of our knowledge, we have not found any paper that would recapitulate the current state of DBS in the context of psychiatric disorders with an addition of technical insights.
Collapse
Affiliation(s)
- Ugo Giordano
- Department of Psychiatry, University Clinical Hospital (USK) in Wroclaw, Wroclaw Medical University, Wroclaw, Poland
| | - Jakub Mizera
- Department of Psychiatry, Students Scientific Association at the Clinic of Psychiatry, Wroclaw Medical University, Wroclaw, Poland
| | - Elżbieta Żak
- Department of Psychiatry, Students Scientific Association at the Clinic of Psychiatry, Wroclaw Medical University, Wroclaw, Poland
| | - Justyna Pilch
- Department of Psychiatry, Students Scientific Association at the Clinic of Psychiatry, Wroclaw Medical University, Wroclaw, Poland
| | - Paulina Tomecka
- Department of Psychiatry, Students Scientific Association at the Clinic of Psychiatry, Wroclaw Medical University, Wroclaw, Poland
| | - Tomasz Dudzik
- Department of Psychiatry, Students Scientific Association at the Clinic of Psychiatry, Wroclaw Medical University, Wroclaw, Poland
| | - Mikołaj Palczewski
- Department of Psychiatry, Students Scientific Association at the Clinic of Psychiatry, Wroclaw Medical University, Wroclaw, Poland
| | - Weronika Biziorek
- Department of Psychiatry, Students Scientific Association at the Clinic of Psychiatry, Wroclaw Medical University, Wroclaw, Poland
| | - Patryk Piotrowski
- Department of Psychiatry, University Clinical Hospital (USK) in Wroclaw, Wroclaw Medical University, Wroclaw, Poland
- Department of Psychiatry, Students Scientific Association at the Clinic of Psychiatry, Wroclaw Medical University, Wroclaw, Poland
| |
Collapse
|
6
|
Kons Z, Hadanny A, Bush A, Nanda P, Herrington TM, Richardson RM. Accurate Deep Brain Stimulation Lead Placement Concurrent With Research Electrocorticography. Oper Neurosurg (Hagerstown) 2023; 24:524-532. [PMID: 36701668 PMCID: PMC10158863 DOI: 10.1227/ons.0000000000000582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 10/14/2022] [Indexed: 01/27/2023] Open
Abstract
BACKGROUND Using electrocorticography for research (R-ECoG) during deep brain stimulation (DBS) surgery has advanced our understanding of human cortical-basal ganglia neurophysiology and mechanisms of therapeutic circuit modulation. The safety of R-ECoG has been established, but potential effects of temporary ECoG strip placement on targeting accuracy have not been reported. OBJECTIVE To determine whether temporary subdural electrode strip placement during DBS implantation surgery affects lead implantation accuracy. METHODS Twenty-four consecutive patients enrolled in a prospective database who underwent awake DBS surgery were identified. Ten of 24 subjects participated in R-ECoG. Lead locations were determined after fusing postoperative computed tomography scans into the surgical planning software. The effect of brain shift was quantified using Lead-DBS and analyzed in a mixed-effects model controlling for time interval to postoperative computed tomography. Targeting accuracy was reported as radial and Euclidean distance errors and compared with Mann-Whitney tests. RESULTS Neither radial error nor Euclidean distance error differed significantly between R-ECoG participants and nonparticipants. Pneumocephalus volume did not differ between the 2 groups, but brain shift was slightly greater with R-ECoG. Pneumocephalus volume correlated with brain shift, but neither of these measures significantly correlated with Euclidean distance error. There were no complications in either group. CONCLUSION In addition to an excellent general safety profile as has been reported previously, these results suggest that performing R-ECoG during DBS implantation surgery does not affect the accuracy of lead placement.
Collapse
Affiliation(s)
- Zachary Kons
- Department of Neurosurgery, Massachusetts General Hospital, Boston, Massachusetts, USA;
- Virginia Commonwealth University School of Medicine, Richmond, Virginia, USA;
| | - Amir Hadanny
- Department of Neurosurgery, Massachusetts General Hospital, Boston, Massachusetts, USA;
| | - Alan Bush
- Department of Neurosurgery, Massachusetts General Hospital, Boston, Massachusetts, USA;
- Harvard Medical School, Boston, Massachusetts, USA;
| | - Pranav Nanda
- Department of Neurosurgery, Massachusetts General Hospital, Boston, Massachusetts, USA;
| | - Todd M. Herrington
- Harvard Medical School, Boston, Massachusetts, USA;
- Department of Neurology, Massachusetts General Hospital, Boston, Massachusetts, USA;
| | - R. Mark Richardson
- Department of Neurosurgery, Massachusetts General Hospital, Boston, Massachusetts, USA;
- Harvard Medical School, Boston, Massachusetts, USA;
| |
Collapse
|
7
|
Slavin KV. Commentary: Targeting Accuracy and Clinical Outcomes of Awake versus Asleep Interventional Magnetic Resonance Imaging-Guided Deep Brain Stimulation for Parkinson's Disease: The University of California, San Francisco Experience. Neurosurgery 2023; 92:e87-e88. [PMID: 36727768 DOI: 10.1227/neu.0000000000002378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 12/04/2022] [Indexed: 02/03/2023] Open
Affiliation(s)
- Konstantin V Slavin
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, Illinois, USA
- Neurology Service, Jesse Brown Veterans Administration Medical Center, Chicago, Illinois, USA
| |
Collapse
|
8
|
Noh SH, Cho PG, Kim KN, Kim SH, Shin DA. Artificial Intelligence for Neurosurgery : Current State and Future Directions. J Korean Neurosurg Soc 2023; 66:113-120. [PMID: 36124365 PMCID: PMC10009243 DOI: 10.3340/jkns.2022.0130] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 09/12/2022] [Indexed: 11/27/2022] Open
Abstract
Artificial intelligence (AI) is a field of computer science that equips machines with human-like intelligence and enables them to learn, reason, and solve problems when presented with data in various formats. Neurosurgery is often at the forefront of innovative and disruptive technologies, which have similarly altered the course of acute and chronic diseases. In diagnostic imaging, such as X-rays, computed tomography, and magnetic resonance imaging, AI is used to analyze images. The use of robots in the field of neurosurgery is also increasing. In neurointensive care units, AI is used to analyze data and provide care to critically ill patients. Moreover, AI can be used to predict a patient's prognosis. Several AI applications have already been introduced in the field of neurosurgery, and many more are expected in the near future. Ultimately, it is our responsibility to keep pace with this evolution to provide meaningful outcomes and personalize each patient's care. Rather than blindly relying on AI in the future, neurosurgeons should gain a thorough understanding of it and use it to enhance their patient care.
Collapse
Affiliation(s)
- Sung Hyun Noh
- Department of Neurosurgery, Ajou University College of Medicine, Suwon, Korea.,Department of Neurosurgery, Yonsei University College of Medicine, Seoul, Korea
| | - Pyung Goo Cho
- Department of Neurosurgery, Ajou University College of Medicine, Suwon, Korea
| | - Keung Nyun Kim
- Department of Neurosurgery, Yonsei University College of Medicine, Seoul, Korea.,Department of Neurosurgery, Spine and Spinal Cord Institute, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Sang Hyun Kim
- Department of Neurosurgery, Ajou University College of Medicine, Suwon, Korea
| | - Dong Ah Shin
- Department of Neurosurgery, Yonsei University College of Medicine, Seoul, Korea.,Department of Neurosurgery, Spine and Spinal Cord Institute, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
9
|
Kremer NI, van Laar T, Lange SF, Statius Muller S, la Bastide-van Gemert S, Oterdoom DM, Drost G, van Dijk JMC. STN-DBS electrode placement accuracy and motor improvement in Parkinson's disease: systematic review and individual patient meta-analysis. J Neurol Neurosurg Psychiatry 2023; 94:236-244. [PMID: 36207065 DOI: 10.1136/jnnp-2022-329192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Accepted: 09/21/2022] [Indexed: 11/05/2022]
Abstract
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an effective neurosurgical treatment for Parkinson's disease. Surgical accuracy is a critical determinant to achieve an adequate DBS effect on motor performance. A two-millimetre surgical accuracy is commonly accepted, but scientific evidence is lacking. A systematic review and meta-analysis of study-level and individual patient data (IPD) was performed by a comprehensive search in MEDLINE, EMBASE and Cochrane Library. Primary outcome measures were (1) radial error between the implanted electrode and target; (2) DBS motor improvement on the Unified Parkinson's Disease Rating Scale part III (motor examination). On a study level, meta-regression analysis was performed. Also, publication bias was assessed. For IPD meta-analysis, a linear mixed effects model was used. Forty studies (1391 patients) were included, reporting radial errors of 0.45-1.86 mm. Errors within this range did not significantly influence the DBS effect on motor improvement. Additional IPD analysis (206 patients) revealed that a mean radial error of 1.13±0.75 mm did not significantly change the extent of DBS motor improvement. Our meta-analysis showed a huge publication bias on accuracy data in DBS. Therefore, the current literature does not provide an unequivocal upper threshold for acceptable accuracy of STN-DBS surgery. Based on the current literature, DBS-electrodes placed within a 2 mm range of the intended target do not have to be repositioned to enhance motor improvement after STN-DBS for Parkinson's disease. However, an indisputable upper cut-off value for surgical accuracy remains to be established. PROSPERO registration number is CRD42018089539.
Collapse
Affiliation(s)
- Naomi I Kremer
- Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| | - Teus van Laar
- Neurology, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| | - Stèfan F Lange
- Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| | - Sijmen Statius Muller
- Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| | | | - Dl Marinus Oterdoom
- Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| | - Gea Drost
- Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
- Neurology, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| | - J Marc C van Dijk
- Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| |
Collapse
|
10
|
Bex A, Mathon B. Advances, technological innovations, and future prospects in stereotactic brain biopsies. Neurosurg Rev 2022; 46:5. [PMID: 36471144 PMCID: PMC9734929 DOI: 10.1007/s10143-022-01918-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Stereotactic brain biopsy is one of the most frequently performed brain surgeries. This review aimed to expose the latest cutting-edge and updated technologies and innovations available to neurosurgeons to safely perform stereotactic brain biopsy by minimizing the risks of complications and ensuring that the procedure is successful, leading to a histological diagnosis. We also examined methods for improving preoperative, intraoperative, and postoperative workflows. We performed a comprehensive state-of-the-art literature review. Intraoperative histology, fluorescence, and imaging techniques appear as smart tools to improve the diagnostic yield of biopsy. Constant innovations such as optical methods and augmented reality are also being made to increase patient safety. Robotics and integrated imaging techniques provide an enhanced intraoperative workflow. Patients' management algorithms based on early discharge after biopsy optimize the patient's personal experience and make the most efficient possible use of the available hospital resources. Many new trends are emerging, constantly improving patient care and safety, as well as surgical workflow. A parameter that must be considered is the cost-effectiveness of these devices and the possibility of using them on a daily basis. The decision to implement a new instrument in the surgical workflow should also be dependent on the number of procedures per year, the existing stereotactic equipment, and the experience of each center. Research on patients' postbiopsy management is another mandatory approach to enhance the safety profile of stereotactic brain biopsy and patient satisfaction, as well as to reduce healthcare costs.
Collapse
Affiliation(s)
- Alix Bex
- Department of Neurosurgery, CHR Citadelle, Liege, Belgium
| | - Bertrand Mathon
- Department of Neurosurgery, Sorbonne University, APHP, La Pitié-Salpêtrière Hospital, 47-83, Boulevard de L'Hôpital, 75651 Cedex 13, Paris, France.
- ICM, INSERM U 1127, CNRS UMR 7225, UMRS, Paris Brain Institute, Sorbonne University, 1127, Paris, France.
- GRC 23, Brain Machine Interface, APHP, Sorbonne University, Paris, France.
- GRC 33, Robotics and Surgical Innovation, APHP, Sorbonne University, Paris, France.
| |
Collapse
|
11
|
Ma FZ, Liu DF, Yang AC, Zhang K, Meng FG, Zhang JG, Liu HG. Application of the robot-assisted implantation in deep brain stimulation. Front Neurorobot 2022; 16:996685. [PMID: 36531913 PMCID: PMC9755501 DOI: 10.3389/fnbot.2022.996685] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Accepted: 11/21/2022] [Indexed: 08/15/2023] Open
Abstract
INTRODUCTION This work aims to assess the accuracy of robotic assistance guided by a videometric tracker in deep brain stimulation (DBS). METHODS We retrospectively reviewed a total of 30 DBS electrode implantations, assisted by the Remebot robotic system, with a novel frameless videometric registration workflow. Then we selected 30 PD patients who used stereotactic frame surgery to implant electrodes during the same period. For each electrode, accuracy was assessed using radial and axial error. RESULTS The average radial error of the robot-assisted electrode implantation was 1.28 ± 0.36 mm, and the average axial error was 1.20 ± 0.40 mm. No deaths or associated hemorrhages, infections or poor incision healing occurred. CONCLUSION Robot-assisted implantation guided by a videometric tracker is accurate and safe.
Collapse
Affiliation(s)
- Fang-Zhou Ma
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - De-Feng Liu
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - An-Chao Yang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
- Department of Functional Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
| | - Kai Zhang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
- Department of Functional Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
| | - Fan-Gang Meng
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
- Department of Functional Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
| | - Jian-Guo Zhang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
- Department of Functional Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Neurostimulation, Beijing, China
| | - Huan-Guang Liu
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
- Department of Functional Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
| |
Collapse
|
12
|
Comparison of intraoperative imaging guided versus microelectrode recording guided deep brain stimulation for Parkinson's disease: A meta-analysis. Neurocirugia (Astur) 2022. [DOI: 10.1016/j.neucir.2022.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2022]
|
13
|
Lee AT, Han KJ, Nichols N, Sudhakar VR, Burke JF, Wozny TA, Chung JE, Volz MM, Ostrem JL, Martin AJ, Larson PS, Starr PA, Wang DD. Targeting Accuracy and Clinical Outcomes of Awake Vs Asleep Interventional MRI-Guided Deep Brain Stimulation for Parkinson's Disease: The UCSF Experience. Neurosurgery 2022; 91:717-725. [PMID: 36069560 DOI: 10.1227/neu.0000000000002111] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Accepted: 06/05/2022] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Interventional MRI (iMRI)-guided implantation of deep brain stimulator (DBS) leads has been developed to treat patients with Parkinson's disease (PD) without the need for awake testing. OBJECTIVE Direct comparisons of targeting accuracy and clinical outcomes for awake stereotactic with asleep iMRI-DBS for PD are limited. METHODS We performed a retrospective review of patients with PD who underwent awake or iMRI-guided DBS surgery targeting the subthalamic nucleus or globus pallidus interna between 2013 and 2019 at our institution. Outcome measures included Unified Parkinson's Disease Rating Scale Part III scores, levodopa equivalent daily dose, radial error between intended and actual lead locations, stimulation parameters, and complications. RESULTS Of the 218 patients included in the study, the iMRI cohort had smaller radial errors (iMRI: 1.27 ± 0.72 mm, awake: 1.59 ± 0.96 mm, P < .01) and fewer lead passes (iMRI: 1.0 ± 0.16, awake: 1.2 ± 0.41, P < .01). Changes in Unified Parkinson's Disease Rating Scale were similar between modalities, but awake cases had a greater reduction in levodopa equivalent daily dose than iMRI cases (P < .01), which was attributed to the greater number of awake subthalamic nucleus cases on multivariate analysis. Effective clinical contacts used for stimulation, side effect thresholds, and complication rates were similar between modalities. CONCLUSION Although iMRI-DBS may result in more accurate lead placement for intended target compared with awake-DBS, clinical outcomes were similar between surgical approaches. Ultimately, patient preference and surgeon experience with a given DBS technique should be the main factors when determining the "best" method for DBS implantation.
Collapse
Affiliation(s)
- Anthony T Lee
- Department of Neurological Surgery, Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, California, USA
| | - Kasey J Han
- Department of Neurological Surgery, Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, California, USA
| | - Noah Nichols
- Department of Neurological Surgery, Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, California, USA
| | - Vivek R Sudhakar
- University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania, USA
| | - John F Burke
- Department of Neurological Surgery, Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, California, USA
| | - Thomas A Wozny
- Department of Neurological Surgery, Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, California, USA
| | - Jason E Chung
- Department of Neurological Surgery, Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, California, USA
| | - Monica M Volz
- Department of Neurological Surgery, Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, California, USA
| | - Jill L Ostrem
- Department of Neurology, Movement Disorders and Neuromodulation Center, Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, California, USA
| | - Alastair J Martin
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, USA
| | - Paul S Larson
- Department of Neurological Surgery, Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, California, USA
| | - Philip A Starr
- Department of Neurological Surgery, Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, California, USA
| | - Doris D Wang
- Department of Neurological Surgery, Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, California, USA
| |
Collapse
|
14
|
Hodge JO, Cook P, Brandmeir NJ. Awake Deep Brain Stimulation Surgery Without Intraoperative Imaging Is Accurate and Effective: A Case Series. Oper Neurosurg (Hagerstown) 2022; 23:133-138. [PMID: 35486875 DOI: 10.1227/ons.0000000000000249] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Accepted: 02/09/2022] [Indexed: 01/17/2023] Open
Abstract
BACKGROUND The success of deep brain stimulation (DBS) surgery depends on the accuracy of electrode placement. Several factors can affect this such as brain shift, the quality of preoperative planning, and technical factors. It is crucial to determine whether techniques yield accurate lead placement and effective symptom relief. Many of the studies establishing the accuracy of frameless techniques used intraoperative imaging to further refine lead placement. OBJECTIVE To determine whether awake lead placement without intraoperative imaging can achieve similar minimal targeting error while preserving clinical results. METHODS Eighty-two trajectories in 47 patients who underwent awake, frameless DBS lead placement with the Fred Haer Corporation STarFix system for essential tremor or Parkinson's disease were analyzed. Neurological testing during lead placement was used to determine appropriate lead locations, and no intraoperative imaging was performed. Accuracy data were compared with previously performed studies. RESULTS The Euclidean error for the patient cohort was 1.79 ± 1.02 mm, and the Pythagorean error was 1.40 ± 0.95 mm. The percentage symptom improvement evaluated by the Unified Parkinson's Disease Rating Scale for Parkinson's disease or the Fahn-Tolosa-Marin scale for essential tremor was similar to reported values at 58% ± 17.2% and 67.4% ± 24.7%, respectively. The operative time was 95.0 ± 30.3 minutes for all study patients. CONCLUSION Awake, frameless DBS surgery with the Fred Haer Corporation STarFix system does not require intraoperative imaging for stereotactic accuracy or clinical effectiveness.
Collapse
Affiliation(s)
- Johnie O Hodge
- Department of Neurosurgery, Rockefeller Neuroscience Institute, West Virginia University, Morgantown, West Virginia, USA
| | | | | |
Collapse
|
15
|
Campbell BA, Cho H, Faulhammer RM, Hogue O, Tsai JPC, Hussain MS, Machado AG, Baker KB. Stability and Effect of Parkinsonian State on Deep Brain Stimulation Cortical Evoked Potentials. Neuromodulation 2022; 25:804-816. [PMID: 34309115 PMCID: PMC10246651 DOI: 10.1111/ner.13508] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 06/09/2021] [Accepted: 07/06/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To characterize and compare the stability of cortical potentials evoked by deep brain stimulation (DBS) of the subthalamic nucleus (STN) across the naïve, parkinsonian, and pharmacologically treated parkinsonian states. To advance cortical potentials as possible biomarkers for DBS programming. MATERIALS AND METHODS Serial electrocorticographic (ECoG) recordings were made more than nine months from a single non-human primate instrumented with bilateral ECoG grids spanning anterior parietal to prefrontal cortex. Cortical evoked potentials (CEPs) were generated through time-lock averaging of the ECoG recordings to DBS pulses delivered unilaterally in the STN region using a chronically implanted, six-contact, scaled DBS lead. Recordings were made across the naïve followed by mild and moderate parkinsonian conditions achieved by staged injections of the 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP) neurotoxin. In addition to characterizing the spatial distribution and stability of the response within each state, changes in the amplitude and latency of CEP components as well as in the frequency content were examined in relation to parkinsonian severity and dopamine replacement. RESULTS In the naïve state, the STN DBS CEP presented as a multiphase response maximal over M1 cortex, with components attributable to physiological activity distinguishable from stimulus artifact as early as 0.45-0.75 msec poststimulation. When delivered using therapeutically effective parameters in the parkinsonian state, the CEP was highly stable across multiple recording sessions within each behavioral state. Across states, significant differences were present with respect to both the latency and amplitude of individual response components, with greater differences present for longer-latency components (all p < 0.05). Power spectral density analysis revealed a high-beta peak within the evoked response, with significant changes in power between disease states across multiple frequency bands. CONCLUSIONS Our findings underscore the spatiotemporal specificity and relative stability of the DBS-CEP associated with different disease states and with therapeutic benefit. DBS-CEP may be a viable biomarker for therapeutic programming.
Collapse
Affiliation(s)
- Brett A Campbell
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA; Department of Neurosciences, Cleveland Clinic, Cleveland, OH, USA
| | - Hanbin Cho
- Department of Neurosciences, Cleveland Clinic, Cleveland, OH, USA
| | | | - Olivia Hogue
- Department of Quantitative Health Sciences, Cleveland Clinic, Cleveland, OH, USA
| | | | | | - Andre G Machado
- Neurological Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Kenneth B Baker
- Department of Neurosciences, Cleveland Clinic, Cleveland, OH, USA.
| |
Collapse
|
16
|
Sinclair NC, McDermott HJ, Lee WL, Xu SS, Acevedo N, Begg A, Perera T, Thevathasan W, Bulluss KJ. Electrically evoked and spontaneous neural activity in the subthalamic nucleus under general anesthesia. J Neurosurg 2022; 137:449-458. [PMID: 34891136 DOI: 10.3171/2021.8.jns204225] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Accepted: 08/09/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Deep brain stimulation (DBS) surgery is commonly performed with the patient awake to facilitate assessments of electrode positioning. However, awake neurosurgery can be a barrier to patients receiving DBS. Electrode implantation can be performed with the patient under general anesthesia (GA) using intraoperative imaging, although such techniques are not widely available. Electrophysiological features can also aid in the identification of target neural regions and provide functional evidence of electrode placement. Here we assess the presence and positional variation under GA of spontaneous beta and high-frequency oscillation (HFO) activity, and evoked resonant neural activity (ERNA), a novel evoked response localized to the subthalamic nucleus. METHODS ERNA, beta, and HFO were intraoperatively recorded from DBS leads comprising four individual electrodes immediately after bilateral awake implantation into the subthalamic nucleus of 21 patients with Parkinson's disease (42 hemispheres) and after subsequent GA induction deep enough to perform pulse generator implantation. The main anesthetic agent was either propofol (10 patients) or sevoflurane (11 patients). RESULTS GA reduced the amplitude of ERNA, beta, and HFO activity (p < 0.001); however, ERNA amplitudes remained large in comparison to spontaneous local field potentials. Notably, a moderately strong correlation between awake ERNA amplitude and electrode distance to an "ideal" therapeutic target within dorsal STN was preserved under GA (awake: ρ = -0.73, adjusted p value [padj] < 0.001; GA: ρ = -0.69, padj < 0.001). In contrast, correlations were diminished under GA for beta (awake: ρ = -0.45, padj < 0.001; GA: ρ = -0.13, padj = 0.12) and HFO (awake: ρ = -0.69, padj < 0.001; GA: ρ = -0.33, padj < 0.001). The largest ERNA occurred at the same electrode (awake vs GA) for 35/42 hemispheres (83.3%) and corresponded closely to the electrode selected by the clinician for chronic therapy at 12 months (awake ERNA 77.5%, GA ERNA 82.5%). The largest beta amplitude occurred at the same electrode (awake vs GA) for only 17/42 (40.5%) hemispheres and 21/42 (50%) for HFO. The electrode measuring the largest awake beta and HFO amplitudes corresponded to the electrode selected by the clinician for chronic therapy at 12 months in 60% and 70% of hemispheres, respectively. However, this correspondence diminished substantially under GA (beta 20%, HFO 35%). CONCLUSIONS ERNA is a robust electrophysiological signal localized to the dorsal subthalamic nucleus subregion that is largely preserved under GA, indicating it could feasibly guide electrode implantation, either alone or in complementary use with existing methods.
Collapse
Affiliation(s)
- Nicholas C Sinclair
- 1Bionics Institute, East Melbourne
- 2Medical Bionics Department, The University of Melbourne, East Melbourne
| | - Hugh J McDermott
- 1Bionics Institute, East Melbourne
- 2Medical Bionics Department, The University of Melbourne, East Melbourne
| | | | - San San Xu
- 1Bionics Institute, East Melbourne
- 3Department of Neurology, Austin Hospital, Heidelberg
| | | | | | - Thushara Perera
- 1Bionics Institute, East Melbourne
- 2Medical Bionics Department, The University of Melbourne, East Melbourne
| | - Wesley Thevathasan
- 1Bionics Institute, East Melbourne
- 3Department of Neurology, Austin Hospital, Heidelberg
- 5Department of Medicine, The University of Melbourne, Parkville
| | - Kristian J Bulluss
- 1Bionics Institute, East Melbourne
- 6Department of Neurosurgery, St. Vincent's and Austin Hospitals, Melbourne; and
- 7Department of Surgery, The University of Melbourne, Heidelberg, Victoria, Australia
| |
Collapse
|
17
|
Malvea A, Babaei F, Boulay C, Sachs A, Park J. Deep brain stimulation for Parkinson’s Disease: A Review and Future Outlook. Biomed Eng Lett 2022; 12:303-316. [PMID: 35892031 PMCID: PMC9308849 DOI: 10.1007/s13534-022-00226-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 12/29/2021] [Accepted: 04/03/2022] [Indexed: 11/30/2022] Open
Abstract
Parkinson's Disease (PD) is a neurodegenerative disorder that manifests as an impairment of motor and non-motor abilities due to a loss of dopamine input to deep brain structures. While there is presently no cure for PD, a variety of pharmacological and surgical therapeutic interventions have been developed to manage PD symptoms. This review explores the past, present and future outlooks of PD treatment, with particular attention paid to deep brain stimulation (DBS), the surgical procedure to deliver DBS, and its limitations. Finally, our group's efforts with respect to brain mapping for DBS targeting will be discussed.
Collapse
Affiliation(s)
- Anahita Malvea
- Faculty of Medicine, University of Ottawa, K1H 8M5 Ottawa, ON Canada
| | - Farbod Babaei
- School of Electrical Engineering and Computer Science, University of Ottawa, K1N 6N5 Ottawa, ON Canada
| | - Chadwick Boulay
- The Ottawa Hospital Research Institute, Ottawa, Ontario Canada
- The University of Ottawa Brain and Mind Research Institute, Ottawa, Ontario Canada
| | - Adam Sachs
- The Ottawa Hospital Research Institute, Ottawa, Ontario Canada
- The University of Ottawa Brain and Mind Research Institute, Ottawa, Ontario Canada
- Division of Neurosurgery, Department of Surgery, The Ottawa Hospital, Ottawa, Ontario Canada
| | - Jeongwon Park
- School of Electrical Engineering and Computer Science, University of Ottawa, K1N 6N5 Ottawa, ON Canada
- Department of Electrical and Biomedical Engineering, University of Nevada, 89557 Reno, NV USA
| |
Collapse
|
18
|
Kochanski RB, Slavin KV. The future perspectives of psychiatric neurosurgery. PROGRESS IN BRAIN RESEARCH 2022; 270:211-228. [PMID: 35396029 DOI: 10.1016/bs.pbr.2022.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The future of psychiatric neurosurgery can be viewed from two separate perspectives: the immediate future and the distant future. Both show promise, but the treatment strategy for mental diseases and the technology utilized during these separate periods will likely differ dramatically. It can be expected that the initial advancements will be built upon progress of neuroimaging and stereotactic targeting while surgical technology becomes adapted to patient-specific symptomatology and structural/functional imaging parameters. This individualized approach has already begun to show significant promise when applied to deep brain stimulation for treatment-resistant depression and obsessive-compulsive disorder. If effectiveness of these strategies is confirmed by well designed, double-blind, placebo-controlled clinical studies, further technological advances will continue into the distant future, and will likely involve precise neuromodulation at the cellular level, perhaps using wireless technology with or without closed-loop design. This approach, being theoretically less invasive and carrying less risk, may ultimately propel psychiatric neurosurgery to the forefront in the treatment algorithm of mental illness. Despite prominent development of non-invasive therapeutic options, such as stereotactic radiosurgery or transcranial magnetic resonance-guided focused ultrasound, chances are there will still be a need in surgical management of patients with most intractable psychiatric conditions.
Collapse
Affiliation(s)
- Ryan B Kochanski
- Neurosurgery, Methodist Healthcare System, San Antonio, TX, United States
| | - Konstantin V Slavin
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, IL, United States; Neurology Service, Jesse Brown Veterans Administration Medical Center, Chicago, IL, United States.
| |
Collapse
|
19
|
Ose T, Autio JA, Ohno M, Frey S, Uematsu A, Kawasaki A, Takeda C, Hori Y, Nishigori K, Nakako T, Yokoyama C, Nagata H, Yamamori T, Van Essen DC, Glasser MF, Watabe H, Hayashi T. Anatomical variability, multi-modal coordinate systems, and precision targeting in the marmoset brain. Neuroimage 2022; 250:118965. [PMID: 35122965 PMCID: PMC8948178 DOI: 10.1016/j.neuroimage.2022.118965] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 01/31/2022] [Accepted: 02/01/2022] [Indexed: 01/02/2023] Open
Abstract
Localising accurate brain regions needs careful evaluation in each experimental species due to their individual variability. However, the function and connectivity of brain areas is commonly studied using a single-subject cranial landmark-based stereotactic atlas in animal neuroscience. Here, we address this issue in a small primate, the common marmoset, which is increasingly widely used in systems neuroscience. We developed a non-invasive multi-modal neuroimaging-based targeting pipeline, which accounts for intersubject anatomical variability in cranial and cortical landmarks in marmosets. This methodology allowed creation of multi-modal templates (MarmosetRIKEN20) including head CT and brain MR images, embedded in coordinate systems of anterior and posterior commissures (AC-PC) and CIFTI grayordinates. We found that the horizontal plane of the stereotactic coordinate was significantly rotated in pitch relative to the AC-PC coordinate system (10 degrees, frontal downwards), and had a significant bias and uncertainty due to positioning procedures. We also found that many common cranial and brain landmarks (e.g., bregma, intraparietal sulcus) vary in location across subjects and are substantial relative to average marmoset cortical area dimensions. Combining the neuroimaging-based targeting pipeline with robot-guided surgery enabled proof-of-concept targeting of deep brain structures with an accuracy of 0.2 mm. Altogether, our findings demonstrate substantial intersubject variability in marmoset brain and cranial landmarks, implying that subject-specific neuroimaging-based localization is needed for precision targeting in marmosets. The population-based templates and atlases in grayordinates, created for the first time in marmoset monkeys, should help bridging between macroscale and microscale analyses.
Collapse
Affiliation(s)
- Takayuki Ose
- Laboratory for Brain Connectomics Imaging, RIKEN Center for Biosystems Dynamics Research, Kobe, Japan; Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan.
| | - Joonas A Autio
- Laboratory for Brain Connectomics Imaging, RIKEN Center for Biosystems Dynamics Research, Kobe, Japan.
| | - Masahiro Ohno
- Laboratory for Brain Connectomics Imaging, RIKEN Center for Biosystems Dynamics Research, Kobe, Japan.
| | | | - Akiko Uematsu
- Laboratory for Brain Connectomics Imaging, RIKEN Center for Biosystems Dynamics Research, Kobe, Japan.
| | - Akihiro Kawasaki
- Laboratory for Brain Connectomics Imaging, RIKEN Center for Biosystems Dynamics Research, Kobe, Japan.
| | - Chiho Takeda
- Laboratory for Brain Connectomics Imaging, RIKEN Center for Biosystems Dynamics Research, Kobe, Japan.
| | - Yuki Hori
- Laboratory for Brain Connectomics Imaging, RIKEN Center for Biosystems Dynamics Research, Kobe, Japan; Department of Functional Brain Imaging, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan.
| | - Kantaro Nishigori
- Laboratory for Brain Connectomics Imaging, RIKEN Center for Biosystems Dynamics Research, Kobe, Japan; Sumitomo Dainippon Pharma Co., Ltd., Osaka, Japan.
| | - Tomokazu Nakako
- Laboratory for Brain Connectomics Imaging, RIKEN Center for Biosystems Dynamics Research, Kobe, Japan; Sumitomo Dainippon Pharma Co., Ltd., Osaka, Japan.
| | - Chihiro Yokoyama
- Laboratory for Brain Connectomics Imaging, RIKEN Center for Biosystems Dynamics Research, Kobe, Japan; Faculty of Human life and Environmental Science, Nara women's University, Nara, Japan.
| | | | - Tetsuo Yamamori
- Laboratory for Molecular Analysis of Higher Brain Function, RIKEN Center for Brain Science, Wako, Japan.
| | - David C Van Essen
- Department of Neuroscience, Washington University Medical School, St Louis, MO USA.
| | - Matthew F Glasser
- Department of Neuroscience, Washington University Medical School, St Louis, MO USA; Department of Radiology, Washington University Medical School, St Louis, MO USA.
| | - Hiroshi Watabe
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan.
| | - Takuya Hayashi
- Laboratory for Brain Connectomics Imaging, RIKEN Center for Biosystems Dynamics Research, Kobe, Japan; Department of Brain Connectomics, Kyoto University Graduate School of Medicine, Kyoto, Japan.
| |
Collapse
|
20
|
Vagdargi P, Uneri A, Jones CK, Wu P, Han R, Luciano MG, Anderson WS, Helm PA, Hager GD, Siewerdsen JH. Pre-Clinical Development of Robot-Assisted Ventriculoscopy for 3D Image Reconstruction and Guidance of Deep Brain Neurosurgery. IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS 2022; 4:28-37. [PMID: 35368731 PMCID: PMC8967072 DOI: 10.1109/tmrb.2021.3125322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Conventional neuro-navigation can be challenged in targeting deep brain structures via transventricular neuroendoscopy due to unresolved geometric error following soft-tissue deformation. Current robot-assisted endoscopy techniques are fairly limited, primarily serving to planned trajectories and provide a stable scope holder. We report the implementation of a robot-assisted ventriculoscopy (RAV) system for 3D reconstruction, registration, and augmentation of the neuroendoscopic scene with intraoperative imaging, enabling guidance even in the presence of tissue deformation and providing visualization of structures beyond the endoscopic field-of-view. Phantom studies were performed to quantitatively evaluate image sampling requirements, registration accuracy, and computational runtime for two reconstruction methods and a variety of clinically relevant ventriculoscope trajectories. A median target registration error of 1.2 mm was achieved with an update rate of 2.34 frames per second, validating the RAV concept and motivating translation to future clinical studies.
Collapse
Affiliation(s)
- Prasad Vagdargi
- Department of Computer Science, Johns Hopkins University, Baltimore, MD 21218 USA
| | - Ali Uneri
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Craig K. Jones
- Malone Center for Engineering in Healthcare, Johns Hopkins University, Baltimore, MD USA
| | - Pengwei Wu
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Runze Han
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Mark G. Luciano
- Department of Neurosurgery, Johns Hopkins Medicine, Baltimore, MD, USA
| | | | | | - Gregory D. Hager
- Department of Computer Science, Johns Hopkins University, Baltimore, MD 21218 USA
| | - Jeffrey H. Siewerdsen
- Department of Biomedical Engineering and Department of Computer Science, Johns Hopkins University, Baltimore, MD, USA
| |
Collapse
|
21
|
He C, Zhang F, Li L, Jiang C, Li L. Measurement of Lead Localization Accuracy Based on Magnetic Resonance Imaging. Front Neurosci 2021; 15:632822. [PMID: 35002596 PMCID: PMC8727439 DOI: 10.3389/fnins.2021.632822] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Accepted: 11/04/2021] [Indexed: 11/13/2022] Open
Abstract
Post-implantation localization of deep brain stimulation (DBS) lead based on a magnetic resonance (MR) image is widely used. Existing localization methods use artifact center method or template registration method, which may lead to a considerable deviation of > 2 mm, and result in severe side effects or even surgical failure. Accurate measurement of lead position can instantly inform surgeons of the imprecise implantation. This study aimed to identify the influencing factors in DBS lead post-implantation localization approach, analyze their influence, and describe a localization approach that uses the individual template method to reduce the deviation. We verified that reconstructing direction should be parallel or perpendicular to lead direction, instead of the magnetic field. Besides, we used simplified relationship between magnetic field angle and deviation error to correct the localization results. The mean localization error can be reduced after correction and favors the feasibility of direct localization of DBS lead using MR images. We also discussed influence of in vivo noise on localization frequency and the possibility of using only MR images to localize the contacts.
Collapse
Affiliation(s)
- Changgeng He
- National Engineering Laboratory for Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China
| | - Feng Zhang
- National Engineering Laboratory for Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China
| | - Linze Li
- National Engineering Laboratory for Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China
| | - Changqing Jiang
- National Engineering Laboratory for Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China
| | - Luming Li
- National Engineering Laboratory for Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China
- Precision Medicine and Healthcare Research Center, Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, Shenzhen, China
- IDG/McGovern Institute for Brain Research at Tsinghua University, Beijing, China
- Institute of Epilepsy, Beijing Institute for Brain Disorders, Beijing, China
| |
Collapse
|
22
|
Zhang H, Liu Y, Zhou K, Wei W, Liu Y. Restoring Sensorimotor Function Through Neuromodulation After Spinal Cord Injury: Progress and Remaining Challenges. Front Neurosci 2021; 15:749465. [PMID: 34720867 PMCID: PMC8551759 DOI: 10.3389/fnins.2021.749465] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 09/13/2021] [Indexed: 12/27/2022] Open
Abstract
Spinal cord injury (SCI) is a major disability that results in motor and sensory impairment and extensive complications for the affected individuals which not only affect the quality of life of the patients but also result in a heavy burden for their families and the health care system. Although there are few clinically effective treatments for SCI, research over the past few decades has resulted in several novel treatment strategies which are related to neuromodulation. Neuromodulation-the use of neuromodulators, electrical stimulation or optogenetics to modulate neuronal activity-can substantially promote the recovery of sensorimotor function after SCI. Recent studies have shown that neuromodulation, in combination with other technologies, can allow paralyzed patients to carry out intentional, controlled movement, and promote sensory recovery. Although such treatments hold promise for completely overcoming SCI, the mechanisms by which neuromodulation has this effect have been difficult to determine. Here we review recent progress relative to electrical neuromodulation and optogenetics neuromodulation. We also examine potential mechanisms by which these methods may restore sensorimotor function. We then highlight the strengths of these approaches and remaining challenges with respect to its application.
Collapse
Affiliation(s)
- Hui Zhang
- Jiangsu Key Laboratory of Neuropsychiatric Diseases and Institute of Neuroscience, Soochow University, Suzhou, China
| | - Yaping Liu
- Jiangsu Key Laboratory of Neuropsychiatric Diseases and Institute of Neuroscience, Soochow University, Suzhou, China
| | - Kai Zhou
- Jiangsu Key Laboratory of Neuropsychiatric Diseases and Institute of Neuroscience, Soochow University, Suzhou, China
| | - Wei Wei
- Jiangsu Key Laboratory of Neuropsychiatric Diseases and Institute of Neuroscience, Soochow University, Suzhou, China
| | - Yaobo Liu
- Jiangsu Key Laboratory of Neuropsychiatric Diseases and Institute of Neuroscience, Soochow University, Suzhou, China
| |
Collapse
|
23
|
Zappalá S, Bennion NJ, Potts MR, Wu J, Kusmia S, Jones DK, Evans SL, Marshall D. Full-field MRI measurements of in-vivo positional brain shift reveal the significance of intra-cranial geometry and head orientation for stereotactic surgery. Sci Rep 2021; 11:17684. [PMID: 34480073 PMCID: PMC8417262 DOI: 10.1038/s41598-021-97150-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 08/13/2021] [Indexed: 11/15/2022] Open
Abstract
Positional brain shift (PBS), the sagging of the brain under the effect of gravity, is comparable in magnitude to the margin of error for the success of stereotactic interventions ([Formula: see text] 1 mm). This non-uniform shift due to slight differences in head orientation can lead to a significant discrepancy between the planned and the actual location of surgical targets. Accurate in-vivo measurements of this complex deformation are critical for the design and validation of an appropriate compensation to integrate into neuronavigational systems. PBS arising from prone-to-supine change of head orientation was measured with magnetic resonance imaging on 11 young adults. The full-field displacement was extracted on a voxel-basis via digital volume correlation and analysed in a standard reference space. Results showed the need for target-specific correction of surgical targets, as a significant displacement ranging from 0.52 to 0.77 mm was measured at surgically relevant structures. Strain analysis further revealed local variability in compressibility: anterior regions showed expansion (both volume and shape change), whereas posterior regions showed small compression, mostly dominated by shape change. Finally, analysis of correlation demonstrated the potential for further patient- and intervention-specific adjustments, as intra-cranial breadth and head tilt correlated with PBS reaching statistical significance.
Collapse
Affiliation(s)
- Stefano Zappalá
- School of Computer Science and Informatics, Cardiff University, Cardiff, UK.
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, UK.
| | | | | | - Jing Wu
- School of Computer Science and Informatics, Cardiff University, Cardiff, UK
| | - Slawomir Kusmia
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, UK
- Centre for Medical Image Computing, University College London, London, UK
- MRI Unit, Epilepsy Society, Chalfont St Peter, UK
| | - Derek K Jones
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, UK
| | - Sam L Evans
- School of Engineering, Cardiff University, Cardiff, UK
| | - David Marshall
- School of Computer Science and Informatics, Cardiff University, Cardiff, UK
| |
Collapse
|
24
|
Holanda VM, Eisinger RS, Almeida L, Tsuboi T, Wang H, Okun MS, Deeb W, Patterson A, Wagle Shukla A, Lobo Lopes J, Foote KD. Evolution of Globus Pallidus Targeting for Parkinson's and Dystonia Deep Brain Stimulation: A 15-Year Experience. Front Neurol 2021; 12:679918. [PMID: 34456844 PMCID: PMC8387620 DOI: 10.3389/fneur.2021.679918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Accepted: 07/05/2021] [Indexed: 12/02/2022] Open
Abstract
Objective: The aim of this study is to evaluate the evolution of GPi DBS targeting. Methods: This retrospective, single-center study included patients implanted with GPi DBS leads for dystonia or PD during the years 2004 to 2018 at the University of Florida Fixel Institute for Neurological Diseases. Each patient underwent a high-resolution targeting study on the day prior to the surgery, which was fused with a high resolution CT scan that was acquired on the day of the procedure. Intraoperative target location was selected using a digitized 3D Schaltenbrand-Bailey atlas. All patients underwent a high-resolution head CT scan without contrast approximately one month after lead implantation and accurate measurement of neuroanatomical lead position was acquired after fusion of pre-operative and post-operative image studies. Results: We analyzed 253 PD patients with 352 leads and 80 dystonia patients with 141 leads. During 15 years of follow-up, lead locations in the PD group migrated more laterally (β = 0.09, p < 0.0001), posteriorly [slope (β) = 0.04, p < 0.05], and dorsally (β = 0.07, p < 0.001), whereas leads in the dystonia group did not significantly change position aside from a trend in the dorsal direction (β = 0.06, p = 0.053). Conclusion: The evolving target likely results from multiple factors including improvements in targeting techniques and clinical feedback intraoperatively and post-operatively. Our demonstrates the potential importance of a systematic post-operative DBS lead measurement protocol to ensure quality control and to inform and optimize DBS programming.
Collapse
Affiliation(s)
- Vanessa M Holanda
- Department of Neurosurgery, Center of Neurology and Neurosurgery Associates (NeuroCENNA), Beneficencia Portuguesa of São Paulo Hospital, São Paulo, Brazil
| | - Robert Stephen Eisinger
- Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida Health, Gainesville, FL, United States
| | - Leonardo Almeida
- Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida Health, Gainesville, FL, United States
| | - Takashi Tsuboi
- Department of Neurology, Nagoya University, Nagoya, Japan
| | - Huimin Wang
- Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida Health, Gainesville, FL, United States
| | - Michael S Okun
- Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida Health, Gainesville, FL, United States
| | - Wissam Deeb
- Department of Neurology, University of Massachusetts Medical School, Worcester, MA, United States
| | - Addie Patterson
- Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida Health, Gainesville, FL, United States
| | - Aparna Wagle Shukla
- Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida Health, Gainesville, FL, United States
| | - Janine Lobo Lopes
- Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida Health, Gainesville, FL, United States
| | - Kelly Douglas Foote
- Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida Health, Gainesville, FL, United States
| |
Collapse
|
25
|
Liu DF, Liu HG, Zhang K, Meng FG, Yang AC, Zhang JG. The Clinical Application of Robot-Assisted Ventriculoperitoneal Shunting in the Treatment of Hydrocephalus. Front Neurosci 2021; 15:685142. [PMID: 34421517 PMCID: PMC8376146 DOI: 10.3389/fnins.2021.685142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 07/13/2021] [Indexed: 11/13/2022] Open
Abstract
Background This work aims to assess the effectiveness and safety of robotic assistance in ventriculoperitoneal shunting and to compare the results with data from traditional surgery. Methods We retrospectively analyzed 60 patients who had undergone ventriculoperitoneal shunting, of which shunts were implanted using a robot in 20 patients and using traditional surgical methods in the other 40 patients. Data related to surgery were compared between the two groups, and the accuracy of the drainage tube in the robot-assisted group was assessed. Results In the robot-assisted surgery group, the operation duration was 29.75 ± 6.38 min, intraoperative blood loss was 10.0 ± 3.98 ml, the success rate of a single puncture was 100%, and the bone hole diameter was 4.0 ± 0.3 mm. On the other hand, the operation duration was 48.63 ± 6.60 min, intraoperative blood loss was 22.25 ± 4.52 ml, the success rate of a single puncture was 77.5%, and the bone hole diameter was 11.0 ± 0.2 mm in the traditional surgery group. The above are statistically different between the two groups (P < 0.05). Only one case of surgery-related complications occurred in the robot-assisted group, while 13 cases occurred in the traditional surgery group. There was no significant difference in the hospitalization time. In the robot-assisted surgery group, the average radial error was 2.4 ± 1.5 mm and the average axial error was 1.9 ± 2.1 mm. Conclusion In summary, robot-assisted implantation is accurate, simple to operate, and practical; the duration of surgery is short; trauma to the patient is reduced; and fewer postoperative complications related to surgery are reported.
Collapse
Affiliation(s)
- De-Feng Liu
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Huan-Guang Liu
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.,Department of Functional Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
| | - Kai Zhang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.,Department of Functional Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
| | - Fan-Gang Meng
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.,Department of Functional Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
| | - An-Chao Yang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.,Department of Functional Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
| | - Jian-Guo Zhang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.,Department of Functional Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China.,Beijing Key Laboratory of Neurostimulation, Beijing, China
| |
Collapse
|
26
|
Segar DJ, Tata N, Harary M, Hayes MT, Cosgrove GR. Asleep deep brain stimulation with intraoperative magnetic resonance guidance: a single-institution experience. J Neurosurg 2021; 136:699-708. [PMID: 34359029 DOI: 10.3171/2020.12.jns202572] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Accepted: 12/15/2020] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Deep brain stimulation (DBS) is traditionally performed on an awake patient with intraoperative recordings and test stimulation. DBS performed under general anesthesia with intraoperative MRI (iMRI) has demonstrated high target accuracy, reduced operative time, direct confirmation of target placement, and the ability to place electrodes without cessation of medications. The authors describe their initial experience with using iMRI to perform asleep DBS and discuss the procedural and radiological outcomes of this procedure. METHODS All DBS electrodes were implanted under general anesthesia by a single surgeon by using a neuronavigation system with 3-T iMRI guidance. Clinical outcomes, operative duration, complications, and accuracy were retrospectively analyzed. RESULTS In total, 103 patients treated from 2015 to 2019 were included, and all but 1 patient underwent bilateral implantation. Indications included Parkinson's disease (PD) (65% of patients), essential tremor (ET) (29%), dystonia (5%), and refractory epilepsy (1%). Targets included the globus pallidus pars internus (12.62% of patients), subthalamic nucleus (56.31%), ventral intermedius nucleus of the thalamus (30%), and anterior nucleus of the thalamus (1%). Technically accurate lead placement (radial error ≤ 1 mm) was obtained for 98% of leads, with a mean (95% CI) radial error of 0.50 (0.46-0.54) mm; all leads were placed with a single pass. Predicted radial error was an excellent predictor of real radial error, underestimating real error by only a mean (95% CI) of 0.16 (0.12-0.20) mm. Accuracy remained high irrespective of surgeon experience, but procedure time decreased significantly with increasing institutional and surgeon experience (p = 0.007), with a mean procedure duration of 3.65 hours. Complications included 1 case of intracranial hemorrhage (asymptomatic) and 1 case of venous infarction (symptomatic), and 2 patients had infection at the internal pulse generator site. The mean ± SD voltage was 2.92 ± 0.83 V bilaterally at 1-year follow-up. Analysis of long-term clinical efficacy demonstrated consistent postoperative improvement in clinical symptoms, as well as decreased drug doses across all indications and follow-up time points, including mean decrease in levodopa-equivalent daily dose by 53.57% (p < 0.0001) in PD patients and mean decrease in primidone dose by 61.33% (p < 0.032) in ET patients at 1-year follow-up. CONCLUSIONS A total of 205 leads were placed in 103 patients by a single surgeon under iMRI guidance with few operative complications. Operative time trended downward with increasing institutional experience, and technical accuracy of radiographic lead placement was consistently high. Asleep DBS implantation with iMRI appears to be a safe and effective alternative to standard awake procedures.
Collapse
Affiliation(s)
| | - Nalini Tata
- Departments of1Neurosurgery and.,4Department of Neurosurgery, UCLA, Los Angeles, California
| | - Maya Harary
- Departments of1Neurosurgery and.,3Northwestern Feinberg School of Medicine, Chicago, Illinois; and
| | - Michael T Hayes
- 2Neurology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts
| | | |
Collapse
|
27
|
Ball T, González-Martínez J, Zemmar A, Sweid A, Chandra S, VanSickle D, Neimat JS, Jabbour P, Wu C. Robotic Applications in Cranial Neurosurgery: Current and Future. Oper Neurosurg (Hagerstown) 2021; 21:371-379. [PMID: 34192764 DOI: 10.1093/ons/opab217] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Accepted: 05/16/2021] [Indexed: 12/19/2022] Open
Abstract
Robotics applied to cranial surgery is a fast-moving and fascinating field, which is transforming the practice of neurosurgery. With exponential increases in computing power, improvements in connectivity, artificial intelligence, and enhanced precision of accessing target structures, robots are likely to be incorporated into more areas of neurosurgery in the future-making procedures safer and more efficient. Overall, improved efficiency can offset upfront costs and potentially prove cost-effective. In this narrative review, we aim to translate a broad clinical experience into practical information for the incorporation of robotics into neurosurgical practice. We begin with procedures where robotics take the role of a stereotactic frame and guide instruments along a linear trajectory. Next, we discuss robotics in endoscopic surgery, where the robot functions similar to a surgical assistant by holding the endoscope and providing retraction, supplemental lighting, and correlation of the surgical field with navigation. Then, we look at early experience with endovascular robots, where robots carry out tasks of the primary surgeon while the surgeon directs these movements remotely. We briefly discuss a novel microsurgical robot that can perform many of the critical operative steps (with potential for fine motor augmentation) remotely. Finally, we highlight 2 innovative technologies that allow instruments to take nonlinear, predetermined paths to an intracranial destination and allow magnetic control of instruments for real-time adjustment of trajectories. We believe that robots will play an increasingly important role in the future of neurosurgery and aim to cover some of the aspects that this field holds for neurosurgical innovation.
Collapse
Affiliation(s)
- Tyler Ball
- Department of Neurosurgery, University of Louisville, Louisville, Kentucky, USA
| | | | - Ajmal Zemmar
- Department of Neurosurgery, University of Louisville, Louisville, Kentucky, USA.,Department of Neurosurgery, People's Hospital of Zhengzhou University, Henan Provincial People's Hospital, Henan University People's Hospital, Henan University School of Medicine, Zhengzhou, China
| | - Ahmad Sweid
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Sarat Chandra
- Department of Neurosurgery, All India Institute of Medical Science, New Delhi, India
| | | | - Joseph S Neimat
- Department of Neurosurgery, University of Louisville, Louisville, Kentucky, USA
| | - Pascal Jabbour
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Chengyuan Wu
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| |
Collapse
|
28
|
Sammartino F, Taylor P, Chen G, Reynolds RC, Glen D, Krishna V. Functional Neuroimaging During Asleep DBS Surgery: A Proof of Concept Study. Front Neurol 2021; 12:659002. [PMID: 34262518 PMCID: PMC8273165 DOI: 10.3389/fneur.2021.659002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 05/25/2021] [Indexed: 11/30/2022] Open
Abstract
Object: A real-time functional magnetic resonance imaging (fMRI) feedback during ventral intermediate nucleus (VIM) deep brain stimulation (DBS) under general anesthesia (or “asleep” DBS) does not exist. We hypothesized that it was feasible to acquire a reliable and responsive fMRI during asleep VIM DBS surgery. Methods: We prospectively enrolled 10 consecutive patients who underwent asleep DBS for the treatment of medication-refractory essential tremor. Under general anesthesia, we acquired resting-state functional MRI immediately before and after the cannula insertion. Reliability was determined by a temporal signal-to-noise-ratio >100. Responsiveness was determined based on the fMRI signal change upon insertion of the cannula to the VIM. Results: It was feasible to acquire reliable fMRI during asleep DBS surgery. The fMRI signal was responsive to the brain cannula insertion, revealing a reduction in the tremor network's functional connectivity, which did not reach statistical significance in the group analysis. Conclusions: It is feasible to acquire a reliable and responsive fMRI signal during asleep DBS. The acquisition steps and the preprocessing pipeline developed in these experiments will be useful for future investigations to develop fMRI-based feedback for asleep DBS surgery.
Collapse
Affiliation(s)
- Francesco Sammartino
- Department of Neurosurgery, The Ohio State University, Columbus, OH, United States
| | - Paul Taylor
- Scientific and Statistical Computing Core, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, United States
| | - Gang Chen
- Scientific and Statistical Computing Core, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, United States
| | - Richard C Reynolds
- Scientific and Statistical Computing Core, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, United States
| | - Daniel Glen
- Scientific and Statistical Computing Core, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, United States
| | - Vibhor Krishna
- Department of Neurosurgery, The Ohio State University, Columbus, OH, United States
| |
Collapse
|
29
|
Moran C, Sarangmat N, Gerard CS, Barua N, Ashida R, Woolley M, Pietrzyk M, Gill SS. Two Hundred Twenty-Six Consecutive Deep Brain Stimulation Electrodes Placed Using an "Asleep" Technique and the Neuro|MateTM Robot for the Treatment of Movement Disorders. Oper Neurosurg (Hagerstown) 2021; 19:530-538. [PMID: 32629477 DOI: 10.1093/ons/opaa176] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Accepted: 04/15/2020] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Robotics in neurosurgery has demonstrated widening indications and rapid growth in recent years. Robotic precision and reproducibility are especially pertinent to the field of functional neurosurgery. Deep brain stimulation (DBS) requires accurate placement of electrodes in order to maximize efficacy and minimize side effects. In addition, asleep techniques demand clear target visualization and immediate on-table verification of accuracy. OBJECTIVE To describe the surgical technique of asleep DBS surgery using the Neuro|MateTM Robot (Renishaw plc, Wotton-under-Edge, United Kingdom) and examine the accuracy of DBS lead placement in the subthalamic nucleus (STN) for the treatment of movement disorders. METHODS A single-center retrospective review of 113 patients who underwent bilateral STN/Zona Incerta electrode placement was performed. Accuracy of implantation was assessed using 5 measurements, Euclidian distance, radial error, depth error, angular error, and shift error. RESULTS A total of 226 planned vs actual electrode placements were analyzed. The mean 3-dimensional vector error calculated for 226 trajectories was 0.78 +/- 0.37 mm. The mean radial displacement off planned trajectory was 0.6 +/- 0.33 mm. The mean depth error, angular error, and shift error was 0.4 +/- 0.35 mm, 0.4 degrees, and 0.3 mm, respectively. CONCLUSION This report details our institution's method for DBS lead placement in patients under general anaesthesia using anatomical targeting without microelectrode recordings or intraoperative test stimulation for the treatment of movement disorders. This is the largest reported dataset of accuracy results in DBS surgery performed asleep. This novel robot-assisted operative technique results in sub-millimeter accuracy in DBS electrode placement.
Collapse
Affiliation(s)
- Catherine Moran
- Functional Neurosurgery Group, Clinical Neurosciences, University of Bristol, Bristol, United Kingdom.,Department of Neurosurgery, North Bristol Trust, Westbury-on-Trym, United Kingdom
| | - Nagaraja Sarangmat
- Department of Neurology, North Bristol Trust, Westbury-on-Trym, United Kingdom
| | - Carter S Gerard
- Department of Neurosurgery, North Bristol Trust, Westbury-on-Trym, United Kingdom
| | - Neil Barua
- Department of Neurosurgery, North Bristol Trust, Westbury-on-Trym, United Kingdom
| | - Reiko Ashida
- Department of Neurosurgery, North Bristol Trust, Westbury-on-Trym, United Kingdom
| | - Max Woolley
- Functional Neurosurgery Group, Clinical Neurosciences, University of Bristol, Bristol, United Kingdom.,Neurological Products Division, Renishaw Plc, Wotton-under-Edge, United Kingdom
| | - Mariusz Pietrzyk
- Neurological Products Division, Renishaw Plc, Wotton-under-Edge, United Kingdom
| | - Steven S Gill
- Functional Neurosurgery Group, Clinical Neurosciences, University of Bristol, Bristol, United Kingdom.,Department of Neurosurgery, North Bristol Trust, Westbury-on-Trym, United Kingdom
| |
Collapse
|
30
|
Philipp LR, Matias CM, Thalheimer S, Mehta SH, Sharan A, Wu C. Robot-Assisted Stereotaxy Reduces Target Error: A Meta-Analysis and Meta-Regression of 6056 Trajectories. Neurosurgery 2021; 88:222-233. [PMID: 33045739 DOI: 10.1093/neuros/nyaa428] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Accepted: 07/12/2020] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND The pursuit of improved accuracy for localization and electrode implantation in deep brain stimulation (DBS) and stereoelectroencephalography (sEEG) has fostered an abundance of disparate surgical/stereotactic practices. Specific practices/technologies directly modify implantation accuracy; however, no study has described their respective influence in multivariable context. OBJECTIVE To synthesize the known literature to statistically quantify factors affecting implantation accuracy. METHODS A systematic review and meta-analysis was conducted to determine the inverse-variance weighted pooled mean target error (MTE) of implanted electrodes among patients undergoing DBS or sEEG. MTE was defined as Euclidean distance between planned and final electrode tip. Meta-regression identified moderators of MTE in a multivariable-adjusted model. RESULTS A total of 37 eligible studies were identified from a search return of 2,901 potential articles (2002-2018) - 27 DBS and 10 sEEG. Random-effects pooled MTE = 1.91 mm (95% CI: 1.7-2.1) for DBS and 2.34 mm (95% CI: 2.1-2.6) for sEEG. Meta-regression identified study year, robot use, frame/frameless technique, and intraoperative electrophysiologic testing (iEPT) as significant multivariable-adjusted moderators of MTE (P < .0001, R2 = 0.63). Study year was associated with a 0.92-mm MTE reduction over the 16-yr study period (P = .0035), and robot use with a 0.79-mm decrease (P = .0019). Frameless technique was associated with a mean 0.50-mm (95% CI: 0.17-0.84) increase, and iEPT use with a 0.45-mm (95% CI: 0.10-0.80) increase in MTE. Registration method, imaging type, intraoperative imaging, target, and demographics were not significantly associated with MTE on multivariable analysis. CONCLUSION Robot assistance for stereotactic electrode implantation is independently associated with improved accuracy and reduced target error. This remains true regardless of other procedural factors, including frame-based vs frameless technique.
Collapse
Affiliation(s)
- Lucas R Philipp
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania
| | - Caio M Matias
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania
| | - Sara Thalheimer
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania
| | - Shyle H Mehta
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania
| | - Ashwini Sharan
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania
| | - Chengyuan Wu
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania
| |
Collapse
|
31
|
Dlaka D, Švaco M, Chudy D, Jerbić B, Šekoranja B, Šuligoj F, Vidaković J, Romić D, Raguž M. Frameless stereotactic brain biopsy: A prospective study on robot-assisted brain biopsies performed on 32 patients by using the RONNA G4 system. Int J Med Robot 2021; 17:e2245. [PMID: 33591608 DOI: 10.1002/rcs.2245] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 02/12/2021] [Accepted: 02/12/2021] [Indexed: 12/19/2022]
Abstract
BACKGROUND We present a novel robotic neuronavigation system (RONNA G4), used for precise preoperative planning and frameless neuronavigation, developed by a research group from the University of Zagreb and neurosurgeons from the University Hospital Dubrava, Zagreb, Croatia. The aim of study is to provide comprehensive error measurement analysis of the system used for the brain biopsy. METHODS Frameless stereotactic robot-assisted biopsies were performed on 32 consecutive patients. Post-operative CT and MRI scans were assessed to precisely measure and calculate target point error (TPE) and entry point error (EPE). RESULTS The application accuracy of the RONNA system for TPE was 1.95 ± 1.11 mm, while for EPE was 1.42 ± 0.74 mm. The total diagnostic yield was 96.87%. Linear regression showed statistical significance between the TPE and EPE, and the angle of the trajectory on the bone. CONCLUSION The RONNA G4 robotic system is a precise and highly accurate autonomous neurosurgical assistant for performing frameless brain biopsies.
Collapse
Affiliation(s)
- Domagoj Dlaka
- Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Marko Švaco
- Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb, Zagreb, Croatia.,Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Darko Chudy
- Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia.,Croatian Institute for Brain Research, School of Medicine University of Zagreb, Zagreb, Croatia.,Department of Surgery, School of Medicine, University of Zagreb, Zagreb, Croatia
| | - Bojan Jerbić
- Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb, Zagreb, Croatia.,Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Bojan Šekoranja
- Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb, Zagreb, Croatia.,Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Filip Šuligoj
- Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb, Zagreb, Croatia.,Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Josip Vidaković
- Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb, Zagreb, Croatia.,Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Dominik Romić
- Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia
| | - Marina Raguž
- Department of Neurosurgery, University Hospital Dubrava, Zagreb, Croatia.,Croatian Institute for Brain Research, School of Medicine University of Zagreb, Zagreb, Croatia
| |
Collapse
|
32
|
Bezchlibnyk YB, Sharma VD, Naik KB, Isbaine F, Gale JT, Cheng J, Triche SD, Miocinovic S, Buetefisch CM, Willie JT, Boulis NM, Factor SA, Wichmann T, DeLong MR, Gross RE. Clinical outcomes of globus pallidus deep brain stimulation for Parkinson disease: a comparison of intraoperative MRI- and MER-guided lead placement. J Neurosurg 2021; 134:1072-1082. [PMID: 32114534 DOI: 10.3171/2019.12.jns192010] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Accepted: 12/30/2019] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Deep brain stimulation (DBS) lead placement is increasingly performed with the patient under general anesthesia by surgeons using intraoperative MRI (iMRI) guidance without microelectrode recording (MER) or macrostimulation. The authors assessed the accuracy of lead placement, safety, and motor outcomes in patients with Parkinson disease (PD) undergoing DBS lead placement into the globus pallidus internus (GPi) using iMRI or MER guidance. METHODS The authors identified all patients with PD who underwent either MER- or iMRI-guided GPi-DBS lead placement at Emory University between July 2007 and August 2016. Lead placement accuracy and adverse events were determined for all patients. Clinical outcomes were assessed using the Unified Parkinson's Disease Rating Scale (UPDRS) part III motor scores for patients completing 12 months of follow-up. The authors also assessed the levodopa-equivalent daily dose (LEDD) and stimulation parameters. RESULTS Seventy-seven patients were identified (MER, n = 28; iMRI, n = 49), in whom 131 leads were placed. The stereotactic accuracy of the surgical procedure with respect to the planned lead location was 1.94 ± 0.21 mm (mean ± SEM) (95% CI 1.54-2.34) with frame-based MER and 0.84 ± 0.007 mm (95% CI 0.69-0.98) with iMRI. The rate of serious complications was similar, at 6.9% for MER-guided DBS lead placement and 9.4% for iMRI-guided DBS lead placement (RR 0.71 [95% CI 0.13%-3.9%]; p = 0.695). Fifty-seven patients were included in clinical outcome analyses (MER, n = 16; iMRI, n = 41). Both groups had similar characteristics at baseline, although patients undergoing MER-guided DBS had a lower response on their baseline levodopa challenge (44.8% ± 5.4% [95% CI 33.2%-56.4%] vs 61.6% ± 2.1% [95% CI 57.4%-65.8%]; t = 3.558, p = 0.001). Greater improvement was seen following iMRI-guided lead placement (43.2% ± 3.5% [95% CI 36.2%-50.3%]) versus MER-guided lead placement (25.5% ± 6.7% [95% CI 11.1%-39.8%]; F = 5.835, p = 0.019). When UPDRS III motor scores were assessed only in the contralateral hemibody (per-lead analyses), the improvements remained significantly different (37.1% ± 7.2% [95% CI 22.2%-51.9%] and 50.0% ± 3.5% [95% CI 43.1%-56.9%] for MER- and iMRI-guided DBS lead placement, respectively). Both groups exhibited similar reductions in LEDDs (21.2% and 20.9%, respectively; F = 0.221, p = 0.640). The locations of all active contacts and the 2D radial distance from these to consensus coordinates for GPi-DBS lead placement (x, ±20; y, +2; and z, -4) did not differ statistically by type of surgery. CONCLUSIONS iMRI-guided GPi-DBS lead placement in PD patients was associated with significant improvement in clinical outcomes, comparable to those observed following MER-guided DBS lead placement. Furthermore, iMRI-guided DBS implantation produced a similar safety profile to that of the MER-guided procedure. As such, iMRI guidance is an alternative to MER guidance for patients undergoing GPi-DBS implantation for PD.
Collapse
Affiliation(s)
- Yarema B Bezchlibnyk
- 1Department of Neurosurgery and Brain Repair, Morsani School of Medicine, University of South Florida, Tampa, Florida
- 2Department of Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
| | - Vibhash D Sharma
- 3Department of Neurology, University of Kansas Medical Center, Kansas City, Kansas
- 4Department of Neurology, Emory University School of Medicine
| | - Kushal B Naik
- 5Department of Epidemiology, Rollins School of Public Health, Emory University, Atlanta, Georgia, and
| | - Faical Isbaine
- 2Department of Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
| | - John T Gale
- 2Department of Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
| | - Jennifer Cheng
- 2Department of Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
- 6Department of Neurosurgery, University of Kansas Medical Center, Kansas City, Kansas
| | | | | | | | - Jon T Willie
- 2Department of Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
- 4Department of Neurology, Emory University School of Medicine
| | - Nicholas M Boulis
- 2Department of Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
| | | | - Thomas Wichmann
- 4Department of Neurology, Emory University School of Medicine
| | - Mahlon R DeLong
- 4Department of Neurology, Emory University School of Medicine
| | - Robert E Gross
- 2Department of Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
- 4Department of Neurology, Emory University School of Medicine
| |
Collapse
|
33
|
Almahariq F, Sedmak G, Vuletić V, Dlaka D, Orešković D, Marčinković P, Raguž M, Chudy D. The Accuracy of Direct Targeting Using Fusion of MR and CT Imaging for Deep Brain Stimulation of the Subthalamic Nucleus in Patients with Parkinson's Disease. J Neurol Surg A Cent Eur Neurosurg 2021; 82:518-525. [PMID: 33618414 DOI: 10.1055/s-0040-1715826] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
INTRODUCTION In 33 consecutive patients with Parkinson's disease (PD) undergoing awake deep brain stimulation (DBS) without microelectrode recording (MER), we assessed and validated the precision and accuracy of direct targeting of the subthalamic nucleus (STN) using preoperative magnetic resonance imaging (MRI) and stereotactic computed tomography (CT) image fusion combined with immediate postoperative stereotactic CT and postoperative MRI, and we report on the side effects and clinical results up to 6 months' follow-up. MATERIALS AND METHODS Preoperative nonstereotactic MRI and stereotactic CT images were merged and used for planning the trajectory and final lead position. Immediate postoperative stereotactic CT and postoperative nonstereotactic MRI provided the validation of the final electrode position. Changes in the Unified Parkinson's Disease Rating Scale III (UPDRS III) scores and the levodopa equivalent daily doses (LEDD) and appearance of adverse side effects were assessed. RESULTS The mean Euclidian distance (ED) error between the planned position and the final position of the lead in the left STN was 1.69 ± 0.82 mm and that in the right STN was 2.12 ± 1.00. The individual differences between planned and final position in each of the three coordinates were less than 2 mm. The UPDRS III scores improved by 75% and LEDD decreased by 45%. Few patients experienced complications, such as postoperative infection (n = 1), or unwanted side effects, such as emotional instability (n = 1). CONCLUSION Our results confirm that direct targeting of an STN on stereotactic CT merged with MRI could be a valid method for placement the DBS electrode. The magnitude of our targeting error is comparable with the reported errors when using MER and other direct targeting approaches.
Collapse
Affiliation(s)
- Fadi Almahariq
- Department of Neurosurgery, Clinical Hospital Dubrava, Zagreb, Croatia.,Center of Excellence in Basic, Clinical and Translational Neuroscience, Zagreb, Croatia
| | - Goran Sedmak
- Center of Excellence in Basic, Clinical and Translational Neuroscience, Zagreb, Croatia.,Croatian Institute for Brain Research, School of Medicine, University of Zagreb, Zagreb, Croatia
| | - Vladimira Vuletić
- Department of Neurology, School of Medicine, University of Rijeka, University Hospital Rijeka, Rijeka, Croatia
| | - Domagoj Dlaka
- Department of Neurosurgery, Clinical Hospital Dubrava, Zagreb, Croatia
| | - Darko Orešković
- Department of Neurosurgery, Clinical Hospital Dubrava, Zagreb, Croatia
| | - Petar Marčinković
- Department of Neurosurgery, Clinical Hospital Dubrava, Zagreb, Croatia
| | - Marina Raguž
- Department of Neurosurgery, Clinical Hospital Dubrava, Zagreb, Croatia
| | - Darko Chudy
- Department of Neurosurgery, Clinical Hospital Dubrava, Zagreb, Croatia.,Center of Excellence in Basic, Clinical and Translational Neuroscience, Zagreb, Croatia.,Department of Surgery, School of Medicine, University of Zagreb, Zagreb, Croatia
| |
Collapse
|
34
|
van den Munckhof P, Bot M, Schuurman PR. Targeting of the Subthalamic Nucleus in Patients with Parkinson's Disease Undergoing Deep Brain Stimulation Surgery. Neurol Ther 2021; 10:61-73. [PMID: 33565018 PMCID: PMC8140007 DOI: 10.1007/s40120-021-00233-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Accepted: 01/20/2021] [Indexed: 11/29/2022] Open
Abstract
Precise stereotactic targeting of the dorsolateral motor part of the subthalamic nucleus (STN) is paramount for maximizing clinical effectiveness and preventing side effects of deep brain stimulation (DBS) in patients with advanced Parkinson's disease. With recent developments in magnetic resonance imaging (MRI) techniques, direct targeting of the dorsolateral part of the STN is now feasible, together with visualization of the motor fibers in the nearby internal capsule. However, clinically relevant discrepancies were reported when comparing STN borders on MRI to electrophysiological STN borders during microelectrode recordings (MER). Also, one should take into account the possibility of a 3D inaccuracy of up to 2 mm of the applied stereotactic technique. Pneumocephalus and image fusion errors may further increase implantation inaccuracy. Even when implantation has been successful, suboptimal lead anchoring on the skull may cause lead migration during follow-up. Meticulous pre- and intraoperative imaging is therefore indispensable, and so is postoperative imaging when the effects of DBS deteriorate during follow-up. Thus far, most DBS centers employ MRI targeting, multichannel MER, and awake test stimulation in STN surgery, but randomized trials comparing surgery under local versus general anesthesia and additional studies comparing MER-STN borders to high-field MRI-STN may change this clinical practice. Further developments in imaging protocols and improvements in image fusion processes are needed to optimize placement of DBS leads in the dorsolateral motor part of the STN in Parkinson's disease.
Collapse
Affiliation(s)
- Pepijn van den Munckhof
- Department of Neurosurgery, Amsterdam University Medical Centers, Academic Medical Center (AMC), Amsterdam, The Netherlands.
| | - Maarten Bot
- Department of Neurosurgery, Amsterdam University Medical Centers, Academic Medical Center (AMC), Amsterdam, The Netherlands
| | - P Richard Schuurman
- Department of Neurosurgery, Amsterdam University Medical Centers, Academic Medical Center (AMC), Amsterdam, The Netherlands
| |
Collapse
|
35
|
Furlanetti L, Hasegawa H, Oviedova A, Raslan A, Samuel M, Selway R, Ashkan K. O-Arm Stereotactic Imaging in Deep Brain Stimulation Surgery Workflow: A Utility and Cost-Effectiveness Analysis. Stereotact Funct Neurosurg 2020; 99:93-106. [PMID: 33260175 DOI: 10.1159/000510344] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Accepted: 07/21/2020] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Deep brain stimulation (DBS) surgery is an established treatment for movement disorders. Advances in neuroimaging techniques have resulted in improved targeting accuracy that may improve clinical outcomes. This study aimed to evaluate the safety and feasibility of using the Medtronic O-arm device for the acquisition of intraoperative stereotactic imaging, targeting, and localization of DBS electrodes compared with standard stereotactic MRI or computed tomography (CT). METHODS Patients were recruited prospectively into the study. Routine frame-based stereotactic DBS surgery was performed. Intraoperative imaging was used to facilitate and verify the accurate placement of the intracranial electrodes. The acquisition of coordinates and verification of the position of the electrodes using the O-arm were evaluated and compared with conventional stereotactic MRI or CT. Additionally, a systematic review of the literature on the use of intraoperative imaging in DBS surgery was performed. RESULTS Eighty patients were included. The indications for DBS surgery were dystonia, Parkinson's disease, essential tremor, and epilepsy. The globus pallidus internus was the most commonly targeted region (43.7%), followed by the subthalamic nucleus (35%). Stereotactic O-arm imaging reduced the overall surgical time by 68 min, reduced the length of time of acquisition of stereotactic images by 77%, reduced patient exposure to ionizing radiation by 24.2%, significantly reduced operating room (OR) costs per procedure by 31%, and increased the OR and neuroradiology suite availability. CONCLUSIONS The use of the O-arm in DBS surgery workflow significantly reduced the duration of image acquisition, the exposure to ionizing radiation, and costs when compared with standard stereotactic MRI or CT, without reducing accuracy.
Collapse
Affiliation(s)
- Luciano Furlanetti
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, United Kingdom,
| | - Harutomo Hasegawa
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, United Kingdom
| | - Anna Oviedova
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, United Kingdom
| | - Ahmed Raslan
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, United Kingdom
| | - Michael Samuel
- Department of Neurology, King's College Hospital NHS Foundation Trust, London, United Kingdom
| | - Richard Selway
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, United Kingdom
| | - Keyoumars Ashkan
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, United Kingdom
| |
Collapse
|
36
|
Sharma VD, Bezchlibnyk YB, Isbaine F, Naik KB, Cheng J, Gale JT, Miocinovic S, Buetefisch C, Factor SA, Willie JT, Boulis NM, Wichmann T, DeLong MR, Gross RE. Clinical outcomes of pallidal deep brain stimulation for dystonia implanted using intraoperative MRI. J Neurosurg 2020; 133:1582-1594. [PMID: 31604331 DOI: 10.3171/2019.6.jns19548] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Accepted: 06/27/2019] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Lead placement for deep brain stimulation (DBS) using intraoperative MRI (iMRI) relies solely on real-time intraoperative neuroimaging to guide electrode placement, without microelectrode recording (MER) or electrical stimulation. There is limited information, however, on outcomes after iMRI-guided DBS for dystonia. The authors evaluated clinical outcomes and targeting accuracy in patients with dystonia who underwent lead placement using an iMRI targeting platform. METHODS Patients with dystonia undergoing iMRI-guided lead placement in the globus pallidus pars internus (GPi) were identified. Patients with a prior ablative or MER-guided procedure were excluded from clinical outcomes analysis. Burke-Fahn-Marsden Dystonia Rating Scale (BFMDRS) scores and Toronto Western Spasmodic Torticollis Rating Scale (TWSTRS) scores were assessed preoperatively and at 6 and 12 months postoperatively. Other measures analyzed include lead accuracy, complications/adverse events, and stimulation parameters. RESULTS A total of 60 leads were implanted in 30 patients. Stereotactic lead accuracy in the axial plane was 0.93 ± 0.12 mm from the intended target. Nineteen patients (idiopathic focal, n = 7; idiopathic segmental, n = 5; DYT1, n = 1; tardive, n = 2; other secondary, n = 4) were included in clinical outcomes analysis. The mean improvement in BFMDRS score was 51.9% ± 9.7% at 6 months and 63.4% ± 8.0% at 1 year. TWSTRS scores in patients with predominant cervical dystonia (n = 13) improved by 53.3% ± 10.5% at 6 months and 67.6% ± 9.0% at 1 year. Serious complications occurred in 6 patients (20%), involving 8 of 60 implanted leads (13.3%). The rate of serious complications across all patients undergoing iMRI-guided DBS at the authors' institution was further reviewed, including an additional 53 patients undergoing GPi-DBS for Parkinson disease. In this expanded cohort, serious complications occurred in 11 patients (13.3%) involving 15 leads (10.1%). CONCLUSIONS Intraoperative MRI-guided lead placement in patients with dystonia showed improvement in clinical outcomes comparable to previously reported results using awake MER-guided lead placement. The accuracy of lead placement was high, and the procedure was well tolerated in the majority of patients. However, a number of patients experienced serious adverse events that were attributable to the introduction of a novel technique into a busy neurosurgical practice, and which led to the revision of protocols, product inserts, and on-site training.
Collapse
Affiliation(s)
| | - Yarema B Bezchlibnyk
- 3Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
- 4Department of Neurosurgery and Brain Repair, University of South Florida, Tampa, Florida; and
| | - Faical Isbaine
- 3Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
| | - Kushal B Naik
- 6Department of Epidemiology, Rollins School of Public Health, Emory University, Atlanta, Georgia
| | - Jennifer Cheng
- 3Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
- 5Neurosurgery, University of Kansas Medical Center, Kansas City, Kansas
| | - John T Gale
- 3Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
| | | | | | | | - Jon T Willie
- Departments of1Neurology and
- 3Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
| | - Nicholas M Boulis
- 3Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
| | | | | | - Robert E Gross
- Departments of1Neurology and
- 3Neurosurgery, Emory University School of Medicine, Atlanta, Georgia
| |
Collapse
|
37
|
Krauss P, Oertel MF, Baumann-Vogel H, Imbach L, Baumann CR, Sarnthein J, Regli L, Stieglitz LH. Intraoperative Neurophysiologic Assessment in Deep Brain Stimulation Surgery and its Impact on Lead Placement. J Neurol Surg A Cent Eur Neurosurg 2020; 82:18-26. [PMID: 33049794 DOI: 10.1055/s-0040-1716329] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVES While the efficacy of deep brain stimulation (DBS) to treat various neurological disorders is undisputed, the surgical methods differ widely and the importance of intraoperative microelectrode recording (MER) or macrostimulation (MS) remains controversially debated. The objective of this study is to evaluate the impact of MER and MS on intraoperative lead placement. PATIENTS AND METHODS We included 101 patients who underwent awake bilateral implantation of electrodes in the subthalamic nucleus with MER and MS for Parkinson's disease from 2009 to 2017 in a retrospective observational study. We analyzed intraoperative motor outcomes between anatomically planned stimulation point (PSP) and definite stimulation point (DSP), lead adjustments and Unified Parkinson's Disease Rating Scale Item III (UPDRS-III), levodopa equivalent daily dose (LEDD), and adverse events (AE) after 6 months. RESULTS We adjusted 65/202 leads in 47/101 patients. In adjusted leads, MS results improved significantly when comparing PSP and DSP (p < 0.001), resulting in a number needed to treat of 9.6. After DBS, UPDRS-III and LEDD improved significantly after 6 months in adjusted and nonadjusted patients (p < 0.001). In 87% of leads, the active contact at 6 months still covered the optimal stimulation point during surgery. In total, 15 AE occurred. CONCLUSION MER and MS have a relevant impact on the intraoperative decision of final lead placement and prevent from a substantial rate of poor stimulation outcome. The optimal stimulation points during surgery and chronic stimulation strongly overlap. Follow-up UPDRS-III results, LEDD reductions, and DBS-related AE correspond well to previously published data.
Collapse
Affiliation(s)
- Philipp Krauss
- Department of Neurosurgery, Klinikum rechts der Isar, Technical University of Munich, Germany
| | - Markus Florian Oertel
- Department of Neurosurgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Heide Baumann-Vogel
- Department of Neurology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Lukas Imbach
- Department of Neurology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | | | - Johannes Sarnthein
- Department of Neurosurgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Luca Regli
- Department of Neurosurgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | | |
Collapse
|
38
|
Park HR, Lim YH, Song EJ, Lee JM, Park K, Park KH, Lee WW, Kim HJ, Jeon B, Paek SH. Bilateral Subthalamic Nucleus Deep Brain Stimulation under General Anesthesia: Literature Review and Single Center Experience. J Clin Med 2020; 9:jcm9093044. [PMID: 32967337 PMCID: PMC7564882 DOI: 10.3390/jcm9093044] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 09/13/2020] [Accepted: 09/17/2020] [Indexed: 02/07/2023] Open
Abstract
Bilateral subthalamic nucleus (STN) Deep brain stimulation (DBS) is a well-established treatment in patients with Parkinson's disease (PD). Traditionally, STN DBS for PD is performed by using microelectrode recording (MER) and/or intraoperative macrostimulation under local anesthesia (LA). However, many patients cannot tolerate the long operation time under LA without medication. In addition, it cannot be even be performed on PD patients with poor physical and neurological condition. Recently, it has been reported that STN DBS under general anesthesia (GA) can be successfully performed due to the feasible MER under GA, as well as the technical advancement in direct targeting and intraoperative imaging. The authors reviewed the previously published literature on STN DBS under GA using intraoperative imaging and MER, focused on discussing the technique, clinical outcome, and the complication, as well as introducing our single-center experience. Based on the reports of previously published studies and ours, GA did not interfere with the MER signal from STN. STN DBS under GA without intraoperative stimulation shows similar or better clinical outcome without any additional complication compared to STN DBS under LA. Long-term follow-up with a large number of the patients would be necessary to validate the safety and efficacy of STN DBS under GA.
Collapse
Affiliation(s)
- Hye Ran Park
- Department of Neurosurgery, Soonchunhyang University Seoul Hospital, Seoul 04401, Korea;
| | - Yong Hoon Lim
- Department of Neurosurgery, Seoul National University Hospital, Seoul 03080, Korea; (Y.H.L.); (E.J.S.)
| | - Eun Jin Song
- Department of Neurosurgery, Seoul National University Hospital, Seoul 03080, Korea; (Y.H.L.); (E.J.S.)
| | - Jae Meen Lee
- Department of Neurosurgery, Pusan National University Hospital, Busan 49241, Korea;
| | - Kawngwoo Park
- Department of Neurosurgery, Gachon University Gil Medical Center, Incheon 21565, Korea;
| | - Kwang Hyon Park
- Department of Neurosurgery, Chuungnam National University Sejong Hospital, Sejong 30099, Korea;
| | - Woong-Woo Lee
- Department of Neurology, Nowon Eulji Medical Center, Eulji University, Seoul 01830, Korea;
| | - Han-Joon Kim
- Department of Neurology, Seoul National University Hospital, Seoul 03080, Korea; (H.-J.K.); (B.J.)
| | - Beomseok Jeon
- Department of Neurology, Seoul National University Hospital, Seoul 03080, Korea; (H.-J.K.); (B.J.)
| | - Sun Ha Paek
- Department of Neurosurgery, Seoul National University Hospital, Seoul 03080, Korea; (Y.H.L.); (E.J.S.)
- Correspondence: ; Tel.: +82-22-072-2876
| |
Collapse
|
39
|
Martini ML, Oermann EK, Opie NL, Panov F, Oxley T, Yaeger K. Sensor Modalities for Brain-Computer Interface Technology: A Comprehensive Literature Review. Neurosurgery 2020; 86:E108-E117. [PMID: 31361011 DOI: 10.1093/neuros/nyz286] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 05/04/2019] [Indexed: 12/23/2022] Open
Abstract
Brain-computer interface (BCI) technology is rapidly developing and changing the paradigm of neurorestoration by linking cortical activity with control of an external effector to provide patients with tangible improvements in their ability to interact with the environment. The sensor component of a BCI circuit dictates the resolution of brain pattern recognition and therefore plays an integral role in the technology. Several sensor modalities are currently in use for BCI applications and are broadly either electrode-based or functional neuroimaging-based. Sensors vary in their inherent spatial and temporal resolutions, as well as in practical aspects such as invasiveness, portability, and maintenance. Hybrid BCI systems with multimodal sensory inputs represent a promising development in the field allowing for complimentary function. Artificial intelligence and deep learning algorithms have been applied to BCI systems to achieve faster and more accurate classifications of sensory input and improve user performance in various tasks. Neurofeedback is an important advancement in the field that has been implemented in several types of BCI systems by showing users a real-time display of their recorded brain activity during a task to facilitate their control over their own cortical activity. In this way, neurofeedback has improved BCI classification and enhanced user control over BCI output. Taken together, BCI systems have progressed significantly in recent years in terms of accuracy, speed, and communication. Understanding the sensory components of a BCI is essential for neurosurgeons and clinicians as they help advance this technology in the clinical setting.
Collapse
Affiliation(s)
- Michael L Martini
- Department of Neurosurgery, Mount Sinai Hospital, New York, New York
| | - Eric Karl Oermann
- Department of Neurosurgery, Mount Sinai Hospital, New York, New York
| | - Nicholas L Opie
- Vascular Bionics Laboratory, Department of Medicine, Melbourne University, Melbourne, Australia
| | - Fedor Panov
- Department of Neurosurgery, Mount Sinai Hospital, New York, New York
| | - Thomas Oxley
- Department of Neurosurgery, Mount Sinai Hospital, New York, New York.,Vascular Bionics Laboratory, Department of Medicine, Melbourne University, Melbourne, Australia
| | - Kurt Yaeger
- Department of Neurosurgery, Mount Sinai Hospital, New York, New York
| |
Collapse
|
40
|
Hwang BY, Mampre D, Mills K, Courtney P, Kim MJ, Butala AA, Anderson WS. Non-staged bilateral Globus Pallidus Internus deep brain stimulation lead revision using intraoperative MRI: a case report and literature review. Br J Neurosurg 2020; 35:301-305. [PMID: 32648480 DOI: 10.1080/02688697.2020.1789556] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
BACKGROUND Deep brain stimulation (DBS) lead revision due to suboptimal therapy is common but there is no standardised protocol. We describe a novel technique using iMRI to perform concurrent new Globus Pallidus Internus (GPi) DBS lead implantation and old lead removal in a dystonia patient.Case-description: A 60-year-old woman with medication and neurotoxin-refractory isolated cervical dystonia underwent awake bilateral GPi DBS surgery with MER-guided lead implantation. She initially had a favourable response but later reported suboptimal benefit despite reprogramming. MRI demonstrated suboptimal lead placement and MRI-guided revision surgery under general anesthesia was planned. The goal was to place new leads superior and medial to the existing leads. Using a 1.5 T iMRI and the ClearPoint® NeuroNavigation system, new leads were placed through the existing burr holes, into the new targets with radial errors < 0.08mm bilaterally without crossing the old leads. The old leads were then removed and the new leads connected to the existing pulse generator. The patient tolerated the procedure well and had improved side-effect profile at all contacts at 1-month follow-up. CONCLUSIONS Non-staged iMRI-guided DBS revision surgery under general anesthesia is technically feasible and is an alternative strategy to a staged iMRI-guided revision surgery or an awake MER-guided revision surgery in select patients.
Collapse
Affiliation(s)
- Brian Y Hwang
- Department of Neurosurgery, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - David Mampre
- Department of Neurosurgery, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - Kelly Mills
- Department of Neurology, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - Pamala Courtney
- Department of Radiology, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - Min Jae Kim
- Department of Biomedical Engineering and Neuroscience, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - Ankur A Butala
- Department of Neurology, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - William S Anderson
- Department of Neurosurgery, Johns Hopkins School of Medicine, Baltimore, MD, USA
| |
Collapse
|
41
|
Piano C, Bove F, Mulas D, Bentivoglio AR, Cioni B, Tufo T. Frameless stereotaxy in subthalamic deep brain stimulation: 3-year clinical outcome. Neurol Sci 2020; 42:259-266. [PMID: 32638134 PMCID: PMC7819924 DOI: 10.1007/s10072-020-04561-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Accepted: 07/02/2020] [Indexed: 11/24/2022]
Abstract
Background In most centers, the surgery of deep brain stimulation (DBS) is performed using a stereotactic frame. Compared with frame-based technique, frameless stereotaxy reduces the duration of surgical procedure and patient’s discomfort, with lead placing accuracy equivalent after the learning curve. Although several studies have investigated the targeting accuracy of this technique, only a few studies reported clinical outcomes, with data of short-term follow-up. Objective To assess clinical efficacy and safety of frameless bilateral subthalamic nucleus (STN) DBS in Parkinson’s disease (PD) patients at 1- and 3-year follow-up. Methods Consecutive PD patients who underwent bilateral STN-DBS with a manual adjustable frameless system were included in the study. The data were collected retrospectively. Results Eighteen PD patients underwent bilateral STN-DBS implant and were included in the study. All patients completed 1-year observation and ten of them completed 3-year observation. At 1-year follow-up, motor efficacy of STN stimulation in off-med condition was of 30.1% (P = 0.003) and at 3-year follow-up was of 36.3%, compared with off-stim condition at 3-year follow-up (P = 0.005). Dopaminergic drugs were significantly reduced by 31.2% 1 year after the intervention (P = 0.003) and 31.7% 3 years after the intervention (P = 0.04). No serious adverse events occurred during surgery. Conclusions Frameless stereotaxy is an effective and safe technique for DBS surgery at 1- and 3-year follow-up, with great advantages for patients’ discomfort during surgery.
Collapse
Affiliation(s)
- Carla Piano
- Institute of Neurology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Largo A. Gemelli 8, 00168, Rome, Italy
| | - Francesco Bove
- Institute of Neurology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Largo A. Gemelli 8, 00168, Rome, Italy.
| | - Delia Mulas
- Institute of Neurology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Largo A. Gemelli 8, 00168, Rome, Italy.,Institute of Neurology, Mater Olbia Hospital, Olbia, Italy
| | - Anna Rita Bentivoglio
- Institute of Neurology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Largo A. Gemelli 8, 00168, Rome, Italy
| | - Beatrice Cioni
- Institute of Neurosurgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Tommaso Tufo
- Institute of Neurosurgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy
| |
Collapse
|
42
|
Gravbrot N, Burket A, Saranathan M, Kasoff WS. Asleep Deep Brain Stimulation of the Nucleus Ventralis Intermedius for Essential Tremor Using Indirect Targeting and Interventional Magnetic Resonance Imaging: Single-Institution Case Series. Mov Disord Clin Pract 2020; 7:521-530. [PMID: 32626797 PMCID: PMC7328410 DOI: 10.1002/mdc3.12955] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 03/15/2020] [Accepted: 03/30/2020] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND Literature on asleep deep brain stimulation (DBS) of the ventralis intermedius (Vim) nucleus in essential tremor is relatively sparse. Furthermore, controversy exists as to whether indirect ("consensus" or "atlas-based") targeting of the Vim requires physiologic adjustment for effective clinical outcomes in DBS surgery. OBJECTIVES The objective of this study was to evaluate the clinical results of asleep Vim DBS using indirect coordinates and real-time interventional magnetic resonance imaging guidance. METHODS Retrospective review of a prospectively collected database was performed to identify patients with essential tremor undergoing asleep Vim DBS using interventional magnetic resonance imaging guidance. Stereotactic and clinical outcomes were abstracted and analyzed using descriptive statistics. RESULTS A total of 12 consecutive patients were identified, all of whom were available for 6-month clinical follow-up. Stereotactic (radial) error was 0.5 ± 0.2 mm on the left and 0.5 ± 0.3 mm on the right. Fahn-Tolosa-Marin tremor scores in the treated limb(s) decreased by 71.2% ± 31.0% (P = 0.0088), The Essential Tremor Rating Assessment Scale activities of daily living improved by 74.9% ± 23.7% (P < 0.0001), and The Essential Tremor Rating Assessment Scale performance improved by 64.3 ± 16.2% (P = 0.0004). Surgical complications were mild and generally transient. Stimulation-related side effects were similar to those reported in historical series of awake Vim DBS. CONCLUSIONS Asleep Vim DBS using indirect targeting and interventional magnetic resonance imaging-guided placement is safe and effective, with 6-month clinical results similar to those achieved with awake placement. These data support the use of asleep surgery in essential tremor and represent a baseline for comparison with future studies using more advanced targeting techniques.
Collapse
Affiliation(s)
- Nicholas Gravbrot
- Department of NeurosurgeryUniversity of Arizona College of MedicineTucsonArizonaUSA
| | - Aaron Burket
- Department of NeurosurgeryUniversity of Arizona College of MedicineTucsonArizonaUSA
| | - Manojkumar Saranathan
- Department of Medical ImagingUniversity of Arizona College of MedicineTucsonArizonaUSA
| | - Willard S. Kasoff
- Department of NeurosurgeryUniversity of Arizona College of MedicineTucsonArizonaUSA
| |
Collapse
|
43
|
Katati MJ, Jover VA, Iañez VB, Navarro PMJ, de la Cruz SJ, García OG, Escamilla SF, Mínguez CA. An initial experience with intraoperative O-Arm for deep brain stimulation surgery: can it replace post-operative MRI? Acta Neurol Belg 2020; 120:295-301. [PMID: 30406497 DOI: 10.1007/s13760-018-1037-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Accepted: 10/30/2018] [Indexed: 10/27/2022]
Abstract
Deep brain stimulation (DBS) is used to treat movement disorders, severe psychiatric disorders, and neuropathic pain, among other diseases. Advanced neuroimaging techniques allow direct or indirect localization of the target site, which is verified in many centers by the intraoperative recording of unitary neuronal activity. Intraoperative image acquisition technology (e.g., O-Arm) is increasingly used for accurate electrode positioning throughout the surgery. The aim of our study is to analyze the initial experience of our team in the utilization of O-Arm for planning DBS and monitoring its precision and accuracy throughout the procedure. The study included 13 patients with movement disorders. All underwent DBS with the intraoperative O-arm image acquisition system (iCT) and Medtronic StealthStation S7 cranial planning system, placing a total of 25 electrodes. For each patient, we calculated the difference between real and theoretic x, y, z coordinates, using the paired Student's t test to evaluate absolute and directional differences and the one-sample Student's t test to analyze differences in Euclidean distances. No statistically significant differences were found in absolute, directional, or Euclidean distances between intended and actual x, y, and z coordinates, based on iCT scan. Our experience confirms that utilization of the O-Arm system in DBS provides accurate and precise verification of electrode placements throughout the procedure. Recent studies found no significant differences between iCT and postoperative MRI, the current gold standard. Further prospective studies are warranted to test the elimination of postoperative MRI when this system is used.
Collapse
|
44
|
Thevathasan W, Sinclair NC, Bulluss KJ, McDermott HJ. Tailoring Subthalamic Nucleus Deep Brain Stimulation for Parkinson's Disease Using Evoked Resonant Neural Activity. Front Hum Neurosci 2020; 14:71. [PMID: 32180711 PMCID: PMC7059818 DOI: 10.3389/fnhum.2020.00071] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Accepted: 02/18/2020] [Indexed: 01/15/2023] Open
Affiliation(s)
- Wesley Thevathasan
- Bionics Institute, East Melbourne, VIC, Australia
- Department of Neurology, The Royal Melbourne and Austin Hospitals, Melbourne, VIC, Australia
- Department of Medicine, The University of Melbourne, Melbourne, VIC, Australia
| | - Nicholas C. Sinclair
- Bionics Institute, East Melbourne, VIC, Australia
- Medical Bionics Department, The University of Melbourne, East Melbourne, VIC, Australia
| | - Kristian J. Bulluss
- Bionics Institute, East Melbourne, VIC, Australia
- Department of Neurosurgery, St Vincent's and Austin Hospitals, Melbourne, VIC, Australia
- Department of Surgery, The University of Melbourne, Melbourne, VIC, Australia
| | - Hugh J. McDermott
- Bionics Institute, East Melbourne, VIC, Australia
- Medical Bionics Department, The University of Melbourne, East Melbourne, VIC, Australia
| |
Collapse
|
45
|
Preston C, Alvarez AM, Barragan A, Becker J, Kasoff WS, Witte RS. High resolution transcranial acoustoelectric imaging of current densities from a directional deep brain stimulator. J Neural Eng 2020; 17:016074. [PMID: 31978914 PMCID: PMC7446234 DOI: 10.1088/1741-2552/ab6fc3] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE New innovations in deep brain stimulation (DBS) enable directional current steering-allowing more precise electrical stimulation of the targeted brain structures for Parkinson's disease, essential tremor and other neurological disorders. While intra-operative navigation through MRI or CT approaches millimeter accuracy for placing the DBS leads, no existing modality provides feedback of the currents as they spread from the contacts through the brain tissue. In this study, we investigate transcranial acoustoelectric imaging (tAEI) as a new modality to non-invasively image and characterize current produced from a directional DBS lead. tAEI uses ultrasound (US) to modulate tissue resistivity to generate detectable voltage signals proportional to the local currents. APPROACH An 8-channel directional DBS lead (Infinity 6172ANS, Abbott Inc) was inserted inside three adult human skulls submerged in 0.9% NaCl. A 2.5 MHz linear array delivered US pulses through the transtemporal window and focused near the contacts on the lead, while a custom amplifier and acquisition system recorded the acoustoelectric (AE) interaction used to generate images. MAIN RESULTS tAEI detected monopolar current with stimulation pulses as short as 100 µs with an SNR ranging from 10-27 dB when using safe US pressure (mechanical indices <0.78) and injected current of ~2 mA peak amplitude. Adjacent contacts were discernable along the length and within each ring of the lead with a mean radial separation between contacts of 2.10 and 1.34 mm, respectively. SIGNIFICANCE These results demonstrate the feasibility of tAEI for high resolution mapping of directional DBS currents using clinically-relevant stimulation parameters. This new modality may improve the accuracy for placing the DBS leads, guide calibration and programming, and monitor long-term performance of DBS for treatment of Parkinson's disease.
Collapse
Affiliation(s)
- Chet Preston
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, United States of America
| | - Alexander M Alvarez
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, United States of America
| | - Andres Barragan
- Department of Computer Science, University of Arizona, Tucson, AZ, United States of America
| | - Jennifer Becker
- Department of Medical Imaging, University of Arizona, Tucson, AZ, United States of America
| | - Willard S Kasoff
- Department of Surgery, University of Arizona, Tucson, AZ, United States of America
| | - Russell S Witte
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, United States of America
- Department of Medical Imaging, University of Arizona, Tucson, AZ, United States of America
| |
Collapse
|
46
|
Sudhakar V, Mahmoodi A, Bringas JR, Naidoo J, Kells A, Samaranch L, Fiandaca MS, Bankiewicz KS. Development of a novel frameless skull-mounted ball-joint guide array for use in image-guided neurosurgery. J Neurosurg 2020; 132:595-604. [PMID: 30771782 DOI: 10.3171/2018.10.jns182169] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2018] [Accepted: 10/15/2018] [Indexed: 12/26/2022]
Abstract
OBJECTIVE Successful convection-enhanced delivery of therapeutic agents to subcortical brain structures requires accurate cannula placement. Stereotactic guiding devices have been developed to accurately target brain nuclei. However, technologies remain limited by a lack of MRI compatibility, or by devices' size, making them suboptimal for direct gene delivery to brain parenchyma. The goal of this study was to validate the accuracy of a novel frameless skull-mounted ball-joint guide array (BJGA) in targeting the nonhuman primate (NHP) brain. METHODS Fifteen MRI-guided cannula insertions were performed on 9 NHPs, each targeting the putamen. Optimal trajectories were planned on a standard MRI console using 3D multiplanar baseline images. After cannula insertion, the intended trajectory was compared to the final trajectory to assess deviation (euclidean error) of the cannula tip. RESULTS The average cannula tip deviation was 1.18 ± 0.60 mm (mean ± SD) as measured by 2 independent reviewers. Topological analysis showed a superior, posterior, and rightward directional bias, and the intra- and interclass correlation coefficients were > 0.85, indicating valid and reliable intra- and interobserver evaluation. CONCLUSIONS The data demonstrate that the BJGA can be used to reliably target subcortical brain structures by using MRI guidance, with accuracy comparable to current frameless stereotactic systems. The size and versatility of the BJGA, combined with a streamlined workflow, allows for its potential applicability to a variety of intracranial neurosurgical procedures, and for greater flexibility in executing MRI-guided experiments within the NHP brain.
Collapse
|
47
|
Eleopra R, Rinaldo S, Devigili G, Mondani M, D’Auria S, Lettieri C, Ius T, Skrap M. Frameless Deep Brain Stimulation Surgery: A Single-Center Experience and Retrospective Analysis of Placement Accuracy of 220 Electrodes in a Series of 110 Patients. Stereotact Funct Neurosurg 2020; 97:337-346. [DOI: 10.1159/000503335] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2018] [Accepted: 09/13/2019] [Indexed: 11/19/2022]
|
48
|
Wu A, Halpern C. Essential Tremor: Deep Brain Stimulation. Stereotact Funct Neurosurg 2020. [DOI: 10.1007/978-3-030-34906-6_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
49
|
Shamir RR, Duchin Y, Kim J, Patriat R, Marmor O, Bergman H, Vitek JL, Sapiro G, Bick A, Eliahou R, Eitan R, Israel Z, Harel N. Microelectrode Recordings Validate the Clinical Visualization of Subthalamic-Nucleus Based on 7T Magnetic Resonance Imaging and Machine Learning for Deep Brain Stimulation Surgery. Neurosurgery 2020; 84:749-757. [PMID: 29800386 DOI: 10.1093/neuros/nyy212] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Accepted: 04/26/2018] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a proven and effective therapy for the management of the motor symptoms of Parkinson's disease (PD). While accurate positioning of the stimulating electrode is critical for success of this therapy, precise identification of the STN based on imaging can be challenging. We developed a method to accurately visualize the STN on a standard clinical magnetic resonance imaging (MRI). The method incorporates a database of 7-Tesla (T) MRIs of PD patients together with machine-learning methods (hereafter 7 T-ML). OBJECTIVE To validate the clinical application accuracy of the 7 T-ML method by comparing it with identification of the STN based on intraoperative microelectrode recordings. METHODS Sixteen PD patients who underwent microelectrode-recordings guided STN DBS were included in this study (30 implanted leads and electrode trajectories). The length of the STN along the electrode trajectory and the position of its contacts to dorsal, inside, or ventral to the STN were compared using microelectrode-recordings and the 7 T-ML method computed based on the patient's clinical 3T MRI. RESULTS All 30 electrode trajectories that intersected the STN based on microelectrode-recordings, also intersected it when visualized with the 7 T-ML method. STN trajectory average length was 6.2 ± 0.7 mm based on microelectrode recordings and 5.8 ± 0.9 mm for the 7 T-ML method. We observed a 93% agreement regarding contact location between the microelectrode-recordings and the 7 T-ML method. CONCLUSION The 7 T-ML method is highly consistent with microelectrode-recordings data. This method provides a reliable and accurate patient-specific prediction for targeting the STN.
Collapse
Affiliation(s)
| | - Yuval Duchin
- Surgical Information Sciences, Minneapolis, Minnesota.,Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minnesota
| | - Jinyoung Kim
- Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina
| | - Remi Patriat
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minnesota
| | - Odeya Marmor
- Department of Neurobiology, Institute of Medical Research-Israel Canada (IMRIC), The Hebrew University-Hadassah Medical School, Jerusalem, Israel
| | - Hagai Bergman
- Department of Neurobiology, Institute of Medical Research-Israel Canada (IMRIC), The Hebrew University-Hadassah Medical School, Jerusalem, Israel.,Edmond and Lily Safra Center for Brain Sciences, The Hebrew University, Jerusalem, Israel
| | - Jerrold L Vitek
- Department of Neurology, University of Minnesota, Minneapolis, Minnesota
| | - Guillermo Sapiro
- Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina.,Departments of Biomedical Engineering, Computer Science, and Mathematics, Duke University, Durham, North Carolina
| | - Atira Bick
- Department of Radiology, Hadassah Medical Center, Jerusalem, Israel
| | - Ruth Eliahou
- Department of Radiology, Hadassah Medical Center, Jerusalem, Israel
| | - Renana Eitan
- Department of Neurobiology, Institute of Medical Research-Israel Canada (IMRIC), The Hebrew University-Hadassah Medical School, Jerusalem, Israel.,Functional Neuroimaging Laboratory, Brigham and Women's Hospital, Department of Psychiatry, Harvard Medical School, Boston, Massachusetts
| | - Zvi Israel
- Department of Neurosurgery, Hadassah Medical Center, Jerusalem, Israel
| | - Noam Harel
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minnesota
| |
Collapse
|
50
|
Kundu B, Brock AA, Thompson JA, Rolston JD. Microelectrode Recording in Neurosurgical Patients. Stereotact Funct Neurosurg 2020. [DOI: 10.1007/978-3-030-34906-6_8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|