1
|
Henry B, Merz M, Hoang H, Abdulkarim G, Wosik J, Schoettker P. Cuffless Blood Pressure in clinical practice: challenges, opportunities and current limits. Blood Press 2024; 33:2304190. [PMID: 38245864 DOI: 10.1080/08037051.2024.2304190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 01/07/2024] [Indexed: 01/22/2024]
Abstract
Background: Cuffless blood pressure measurement technologies have attracted significant attention for their potential to transform cardiovascular monitoring.Methods: This updated narrative review thoroughly examines the challenges, opportunities, and limitations associated with the implementation of cuffless blood pressure monitoring systems.Results: Diverse technologies, including photoplethysmography, tonometry, and ECG analysis, enable cuffless blood pressure measurement and are integrated into devices like smartphones and smartwatches. Signal processing emerges as a critical aspect, dictating the accuracy and reliability of readings. Despite its potential, the integration of cuffless technologies into clinical practice faces obstacles, including the need to address concerns related to accuracy, calibration, and standardization across diverse devices and patient populations. The development of robust algorithms to mitigate artifacts and environmental disturbances is essential for extracting clear physiological signals. Based on extensive research, this review emphasizes the necessity for standardized protocols, validation studies, and regulatory frameworks to ensure the reliability and safety of cuffless blood pressure monitoring devices and their implementation in mainstream medical practice. Interdisciplinary collaborations between engineers, clinicians, and regulatory bodies are crucial to address technical, clinical, and regulatory complexities during implementation. In conclusion, while cuffless blood pressure monitoring holds immense potential to transform cardiovascular care. The resolution of existing challenges and the establishment of rigorous standards are imperative for its seamless incorporation into routine clinical practice.Conclusion: The emergence of these new technologies shifts the paradigm of cardiovascular health management, presenting a new possibility for non-invasive continuous and dynamic monitoring. The concept of cuffless blood pressure measurement is viable and more finely tuned devices are expected to enter the market, which could redefine our understanding of blood pressure and hypertension.
Collapse
Affiliation(s)
- Benoit Henry
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Maxime Merz
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Harry Hoang
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Ghaith Abdulkarim
- Neuro-Informatics Laboratory, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
- Department of Neurological Surgery, Mayo Clinic, Rochester, MN, USA
| | - Jedrek Wosik
- Department of Medicine, Duke University School of Medicine, Durham, North Carolina
| | - Patrick Schoettker
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
2
|
Sahranavard T, Alimi R, Arabkhazaei J, Nasrabadi M, Alavi Dana SMM, Gholami Y, Izadi-Moud A, Esmaily H, Ebrahimi M, Ferns GA, Moohebati M, Saffar Soflaei S, Ghayour Mobarhan M. Association of major and minor ECG abnormalities with traditional cardiovascular risk factors in the general population: a large scale study. Sci Rep 2024; 14:11289. [PMID: 38760424 PMCID: PMC11101625 DOI: 10.1038/s41598-024-62142-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Accepted: 05/14/2024] [Indexed: 05/19/2024] Open
Abstract
Cardiovascular disease (CVD) can be determined and quantified using the electrocardiogram (ECG) analysis. Identification of the risk factors associated with ECG abnormalities may advise prevention approaches to decrease CVD burden. In this study we aimed to investigate the association between CVD risk factors and minor and major ECG abnormalities in a general Iranian adult population. This study was conducted in 2010 and covered a population of 9035 males and females aged 35 to 65 years recruiting from the phase I of Mashhad Stroke and Heart Atherosclerotic Disorder (MASHAD) cohort study. The participants were drawn by a stratified cluster random sampling technique. The Bivariate and multinomial logistic regression analysis were conducted considering gender stratification to explore the association of ECG abnormalities with traditional cardiovascular risk factors. There was a significant association between minor and major ECG abnormalities and hypertension (HTN), type 2 diabetes (T2DM), smoking, and physical activity (p < 0.005). There was a significant trend, in both genders, for increasing major abnormalities as the number of CVD risk factors increased. But, only in women, the minor abnormalities increase in frequency as the number of CVD risk factors increased. The results of multinomial logistic regression showed that men with HTN [ARRR = 1.25, 95% CI 0.99, 1.57] and T2DM [ARRR = 1.31, 95% CI 0.99, 1.74] had the highest likelihood to have major abnormalities, although these are not statistically significant. For women, those with HTN had the highest likelihood to have major [ARRR = 1.36, 95% CI 1.13, 1.63] and minor [ARRR = 1.35, 95% CI 1.15, 1.58] abnormalities. Also, women aged > 60 years were more likely to have major [ARRR = 2.01, 95% CI 1.49, 2.74] and minor [ARRR = 1.59, 95% CI 1.20, 2.10] abnormalities compared to women aged < 45 years. Age and HTN were significantly associated with major and minor ECG abnormalities in women, and, on the other hand, HTN and T2DM were associated with major abnormalities in men. Taken together, these findings suggest that healthcare providers should advise preventive approaches to the asymptomatic adults with both major and minor electrocardiographic abnormalities that may predict cardiovascular risk.
Collapse
Affiliation(s)
- Toktam Sahranavard
- International UNESCO Center for Health-Related Basic Sciences and Human Nutrition, Mashhad University of Medical Sciences, Mashhad, 99199-91766, Iran
| | - Rasoul Alimi
- Department of Epidemiology and Biostatistics, School of Health, Torbat Heydariyeh University of Medical Sciences, Torbat Heydariyeh, Iran
| | - Javad Arabkhazaei
- International UNESCO Center for Health-Related Basic Sciences and Human Nutrition, Mashhad University of Medical Sciences, Mashhad, 99199-91766, Iran
| | - Mohamad Nasrabadi
- Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | | | - Yazdan Gholami
- Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Azadeh Izadi-Moud
- Department of Cardiovascular Diseases, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Habiobollah Esmaily
- Department of Biostatistics, School of Health, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mahmoud Ebrahimi
- Vascular and Endovascular Research Center, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Gordon A Ferns
- Division of Medical Education, Brighton & Sussex Medical School, Falmer, Brighton, Sussex, UK
| | - Mohsen Moohebati
- Department of Cardiovascular Diseases, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
- Heart and Vascular Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
| | - Sara Saffar Soflaei
- International UNESCO Center for Health-Related Basic Sciences and Human Nutrition, Mashhad University of Medical Sciences, Mashhad, 99199-91766, Iran.
| | - Majid Ghayour Mobarhan
- International UNESCO Center for Health-Related Basic Sciences and Human Nutrition, Mashhad University of Medical Sciences, Mashhad, 99199-91766, Iran.
| |
Collapse
|
3
|
Landry C, Mukkamala R. Current evidence suggests that estimating blood pressure from convenient ECG waveforms alone is not viable. J Electrocardiol 2023; 81:153-155. [PMID: 37708738 PMCID: PMC10872818 DOI: 10.1016/j.jelectrocard.2023.09.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 08/03/2023] [Accepted: 09/02/2023] [Indexed: 09/16/2023]
Abstract
Cuffless blood pressure (BP) measurement could improve hypertension awareness and control and is being widely pursued. Some have proposed to estimate BP from the electrocardiogram (ECG) alone despite little physiological basis. In this minireview, we extracted the most relevant articles related to ECG-based BP estimation. Our findings suggest that, as expected, estimating BP from ECG does not appear to be viable. Most notably, we have not found any evidence that ECG features can track BP changes. At best, certain ECG features may indicate heart disease and thus correlate with high BP, but this may not be clinically useful.
Collapse
Affiliation(s)
- Cederick Landry
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
| | - Ramakrishna Mukkamala
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA.; Department of Anesthesiology and Perioperative Medicine, University of Pittsburgh, Pittsburgh, PA, USA.
| |
Collapse
|
4
|
Vaseekaran M, Kaese S, Görlich D, Wiemer M, Samol A. WATCH-BPM-Comparison of a WATCH-Type Blood Pressure Monitor with a Conventional Ambulatory Blood Pressure Monitor and Auscultatory Sphygmomanometry. SENSORS (BASEL, SWITZERLAND) 2023; 23:8877. [PMID: 37960576 PMCID: PMC10650650 DOI: 10.3390/s23218877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 09/18/2023] [Accepted: 10/29/2023] [Indexed: 11/15/2023]
Abstract
BACKGROUND Smart devices that are able to measure blood pressure (BP) are valuable for hypertension or heart failure management using digital technology. Data regarding their diagnostic accuracy in comparison to standard noninvasive measurement in accordance to Riva-Rocci are sparse. This study compared a wearable watch-type oscillometric BP monitor (Omron HeartGuide), a wearable watch-type infrared BP monitor (Smart Wear), a conventional ambulatory BP monitor, and auscultatory sphygmomanometry. METHODS Therefore, 159 consecutive patients (84 male, 75 female, mean age 64.33 ± 16.14 years) performed observed single measurements with the smart device compared to auscultatory sphygmomanometry (n = 109) or multiple measurements during 24 h compared to a conventional ambulatory BP monitor on the upper arm (n = 50). The two BP monitoring devices were simultaneously worn on the same arm throughout the monitoring period. In a subgroup of 50 patients, single measurements were also performed with an additional infrared smart device. RESULTS The intraclass correlation coefficient (ICC) between the difference and the mean of the oscillometric Omron HeartGuide and the conventional method for the single measurement was calculated for both systole (0.765) and diastole (0.732). This is exactly how the ICC was calculated for the individual mean values calculated over the 24 h long-term measurement of the individual patients for both systole (0.880) and diastole (0.829). The ICC between the infrared device and the conventional method was "bad" for SBP (0.329) and DBP (0.025). Therefore, no further long-term measurements were performed with the infrared device. CONCLUSION The Omron HeartGuide device provided comparable BP values to the standard devices for single and long-term measurements. The infrared smart device failed to acquire valid measurement data.
Collapse
Affiliation(s)
- Mathini Vaseekaran
- Department of Cardiology and Critical Care Medicine, Johannes Wesling University Hospital, 32429 Minden, Germany; (M.V.); (S.K.); (M.W.)
| | - Sven Kaese
- Department of Cardiology and Critical Care Medicine, Johannes Wesling University Hospital, 32429 Minden, Germany; (M.V.); (S.K.); (M.W.)
| | - Dennis Görlich
- Institute of Biostatistics and Clinical Research, University Münster, 48149 Muenster, Germany;
| | - Marcus Wiemer
- Department of Cardiology and Critical Care Medicine, Johannes Wesling University Hospital, 32429 Minden, Germany; (M.V.); (S.K.); (M.W.)
| | - Alexander Samol
- Department of Cardiology and Critical Care Medicine, Johannes Wesling University Hospital, 32429 Minden, Germany; (M.V.); (S.K.); (M.W.)
- Department of Cardiology and Angiology, St. Antonius-Hospital Gronau GmbH, Möllenweg 22, 48599 Gronau, Germany
| |
Collapse
|
5
|
Alsowaida YS, Shehadeh F, Kalligeros M, Mylonakis E. Incidence and potential risk factors for remdesivir-associated bradycardia in hospitalized patients with COVID-19: A retrospective cohort study. Front Pharmacol 2023; 14:1106044. [PMID: 36817161 PMCID: PMC9930471 DOI: 10.3389/fphar.2023.1106044] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Accepted: 01/16/2023] [Indexed: 02/04/2023] Open
Abstract
Background: Remdesivir is widely used for the management of COVID-19 and several studies have reported bradycardia as a potential side effect associated with this agent. The aim of the present study was to evaluate the incidence rate, severity, and potential risk factors of remdesivir-associated bradycardia. Methods: We performed a retrospective cohort study among hospitalized adult patients with COVID-19 who were treated with remdesivir from March 2020 to October 2021. Our primary outcome of interest was the incidence rate and severity of bradycardia after remdesivir administration. We defined mild bradycardia as a heart rate of 51-59 beats per minute, moderate bradycardia as a heart rate of 41-50 beats per minute, and severe bradycardia as a heart rate of ≤40 beats per minute. We also performed univariable and multivariable regression analyses to determine potential bradycardia risk factors. Baseline characteristics were reported as means with standard deviations or medians with interquartile ranges (IQRs). All the statistical tests are shown as odds ratios (ORs) with 95% confidence intervals (CIs). Results: In total, 1,635 patients were included in this study. The median age with IQR was 68 (57-79) years and 51.7% of the patients were male. In total, 606 (37.1%) patients developed bradycardia. Among them, 437 patients (26.7%) developed mild bradycardia, 158 patients (9.7%) moderate bradycardia, while 11 patients (0.7%) experienced severe bradycardia. In our adjusted multivariate logistic regression, the odds of bradycardia development after remdesivir administration were higher among patients with age ≥65 years (OR 1.76, 95% CI: 1.04-2.99, p = 0.04), those with hypertension (OR 1.37, 95% CI: 1.07-1.75, p = 0.01), and obesity (OR 1.32, 95% CI: 1.02-1.68, p = 0.03). Conclusion: More than 1 out of 3 patients (37%) who received remdesivir for COVID-19 developed bradycardia with the majority of these patients developing mild or moderate bradycardia that is usually a benign manifestation not needing treatment in most cases. Age ≥65 years, hypertension, and obesity were potential risk factors for remdesivir-associated bradycardia among hospitalized COVID-19 patients. Clinicians should be aware of this adverse event and consider close clinical monitoring for patients at high risk for this adverse event.
Collapse
Affiliation(s)
- Yazed Saleh Alsowaida
- Division of Infectious Diseases, Department of Medicine, The Warren Alpert Medical School, Brown University and Rhode Island Hospital, Providence, RI, United States
- Department of Clinical Pharmacy, College of Pharmacy, Hail University, Hail, Saudi Arabia
| | - Fadi Shehadeh
- Division of Infectious Diseases, Department of Medicine, The Warren Alpert Medical School, Brown University and Rhode Island Hospital, Providence, RI, United States
- School of Electrical and Computer Engineering, National Technical University of Athens, Athens, Greece
| | - Markos Kalligeros
- Division of Infectious Diseases, Department of Medicine, The Warren Alpert Medical School, Brown University and Rhode Island Hospital, Providence, RI, United States
| | - Eleftherios Mylonakis
- Division of Infectious Diseases, Department of Medicine, The Warren Alpert Medical School, Brown University and Rhode Island Hospital, Providence, RI, United States
| |
Collapse
|
6
|
Sivajohan B, Elgendi M, Menon C, Allaire C, Yong P, Bedaiwy MA. Clinical use of artificial intelligence in endometriosis: a scoping review. NPJ Digit Med 2022; 5:109. [PMID: 35927426 PMCID: PMC9352729 DOI: 10.1038/s41746-022-00638-1] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 06/24/2022] [Indexed: 02/07/2023] Open
Abstract
Endometriosis is a chronic, debilitating, gynecologic condition with a non-specific clinical presentation. Globally, patients can experience diagnostic delays of ~6 to 12 years, which significantly hinders adequate management and places a significant financial burden on patients and the healthcare system. Through artificial intelligence (AI), it is possible to create models that can extract data patterns to act as inputs for developing interventions with predictive and diagnostic accuracies that are superior to conventional methods and current tools used in standards of care. This literature review explored the use of AI methods to address different clinical problems in endometriosis. Approximately 1309 unique records were found across four databases; among those, 36 studies met the inclusion criteria. Studies were eligible if they involved an AI approach or model to explore endometriosis pathology, diagnostics, prediction, or management and if they reported evaluation metrics (sensitivity and specificity) after validating their models. Only articles accessible in English were included in this review. Logistic regression was the most popular machine learning method, followed by decision tree algorithms, random forest, and support vector machines. Approximately 44.4% (n = 16) of the studies analyzed the predictive capabilities of AI approaches in patients with endometriosis, while 47.2% (n = 17) explored diagnostic capabilities, and 8.33% (n = 3) used AI to improve disease understanding. Models were built using different data types, including biomarkers, clinical variables, metabolite spectra, genetic variables, imaging data, mixed methods, and lesion characteristics. Regardless of the AI-based endometriosis application (either diagnostic or predictive), pooled sensitivities ranged from 81.7 to 96.7%, and pooled specificities ranged between 70.7 and 91.6%. Overall, AI models displayed good diagnostic and predictive capacity in detecting endometriosis using simple classification scenarios (i.e., differentiating between cases and controls), showing promising directions for AI in assessing endometriosis in the near future. This timely review highlighted an emerging area of interest in endometriosis and AI. It also provided recommendations for future research in this field to improve the reproducibility of results and comparability between models, and further test the capacity of these models to enhance diagnosis, prediction, and management in endometriosis patients.
Collapse
Affiliation(s)
- Brintha Sivajohan
- Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
- Department of Obstetrics and Gynecology, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
| | - Mohamed Elgendi
- Department of Obstetrics and Gynecology, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
- Biomedical and Mobile Health Technology Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Carlo Menon
- Biomedical and Mobile Health Technology Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Catherine Allaire
- Department of Obstetrics and Gynecology, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
- British Columbia Women's Hospital, Vancouver, BC, Canada
| | - Paul Yong
- Department of Obstetrics and Gynecology, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
- British Columbia Women's Hospital, Vancouver, BC, Canada
| | - Mohamed A Bedaiwy
- Department of Obstetrics and Gynecology, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.
- British Columbia Women's Hospital, Vancouver, BC, Canada.
| |
Collapse
|
7
|
Ricardo Pires J, Teixeira M, Ferreira F, Viseu I, Afreixo V, Neves C. Electrocardiography in Hypertensive Patients without Cardiovascular Events: A Valuable Predictor Tool? Int J Hypertens 2022; 2022:7038894. [PMID: 35912335 PMCID: PMC9334108 DOI: 10.1155/2022/7038894] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 05/13/2022] [Accepted: 06/12/2022] [Indexed: 11/18/2022] Open
Abstract
Background Hypertension is an important risk factor of cardiovascular (CV) disease. An early diagnosis of target organ damage could prevent major CV events. Electrocardiography (ECG) is a valuable clinical technique, with wide availability and high specificity, used in evaluation of hypertensive patients. However, the use of ECG as a predictor tool is controversial given its low sensitivity. This study aims to characterise ECG features in a hypertensive population and identify ECG abnormalities that could predict CV events. Methods We studied 175 hypertensive patients without previous CV events during a follow-up mean of 4.0 ± 2.20 years. ECGs and pulse wave velocity were performed in all patients. Clinical characteristics and ECG abnormalities were evaluated and compared between the patients as they presented CV events. Results Considering the 175 patients (53.14% male), the median age was 62 years. Median systolic blood pressure was 140 mmHg and diastolic blood pressure was 78 mmHg. Median PWV was 9.8 m/s. Of the patients, 39.4% were diabetic, 78.3% had hyperlipidaemia, and 16.0% had smoking habits. ECG identified left ventricular (LV) hypertrophy in 29.71% of the patients, and a LV strain pattern was present in 9.7% of the patients. Twenty-nine patients (16.57%) had a CV event. Comparative analyses showed statistical significance for the presence of a LV strain pattern in patients with CV events (p=0.01). Univariate and multivariate analysis confirmed that a LV strain pattern was an independent predictor of CV event (HR 2.66, 95% IC 1.01-7.00). In the survival analysis, the Kaplan-Meier curve showed a worse prognosis for CV events in patients with a LV strain pattern (p=0.014). Conclusion ECG is a useful daily method to identify end-organ damage in hypertensive patients. In our study, we also observed that it may be a valuable tool for the prediction of CV events.
Collapse
Affiliation(s)
- J Ricardo Pires
- Internal Medicine Department, Centro Hospitalar Baixo Vouga, Aveiro, Portugal
- University of Aveiro, Aveiro, Portugal
| | - M Teixeira
- Internal Medicine Department, Centro Hospitalar Baixo Vouga, Aveiro, Portugal
| | - F Ferreira
- Internal Medicine Department, Centro Hospitalar Baixo Vouga, Aveiro, Portugal
| | - I Viseu
- University of Aveiro, Aveiro, Portugal
| | - V Afreixo
- University of Aveiro, Aveiro, Portugal
| | - C Neves
- Internal Medicine Department, Centro Hospitalar Baixo Vouga, Aveiro, Portugal
- University of Aveiro, Aveiro, Portugal
| |
Collapse
|
8
|
Tang Q, Chen Z, Guo Y, Liang Y, Ward R, Menon C, Elgendi M. Robust Reconstruction of Electrocardiogram Using Photoplethysmography: A Subject-Based Model. Front Physiol 2022; 13:859763. [PMID: 35547575 PMCID: PMC9082149 DOI: 10.3389/fphys.2022.859763] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 03/21/2022] [Indexed: 11/13/2022] Open
Abstract
Electrocardiography and photoplethysmography are non-invasive techniques that measure signals from the cardiovascular system. While the cycles of the two measurements are highly correlated, the correlation between the waveforms has rarely been studied. Measuring the photoplethysmogram (PPG) is much easier and more convenient than the electrocardiogram (ECG). Recent research has shown that PPG can be used to reconstruct the ECG, indicating that practitioners can gain a deep understanding of the patients’ cardiovascular health using two physiological signals (PPG and ECG) while measuring only PPG. This study proposes a subject-based deep learning model that reconstructs an ECG using a PPG and is based on the bidirectional long short-term memory model. Because the ECG waveform may vary from subject to subject, this model is subject-specific. The model was tested using 100 records from the MIMIC III database. Of these records, 50 had a circulatory disease. The results show that a long ECG signal could be effectively reconstructed from PPG, which is, to our knowledge, the first attempt in this field. A length of 228 s of ECG was constructed by the model, which was trained and validated using 60 s of PPG and ECG signals. To segment the data, a different approach that segments the data into short time segments of equal length (and that do not rely on beats and beat detection) was investigated. Segmenting the PPG and ECG time series data into equal segments of 1-min width gave the optimal results. This resulted in a high Pearson’s correlation coefficient between the reconstructed 228 s of ECG and referenced ECG of 0.818, while the root mean square error was only 0.083 mV, and the dynamic time warping distance was 2.12 mV per second on average.
Collapse
Affiliation(s)
- Qunfeng Tang
- School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China.,Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
| | - Zhencheng Chen
- School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China
| | - Yanke Guo
- School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China
| | - Yongbo Liang
- School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China
| | - Rabab Ward
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
| | - Carlo Menon
- Biomedical and Mobile Health Technology Laboratory, Department of Health Sciences and Technology, Zurich, Switzerland
| | - Mohamed Elgendi
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada.,Biomedical and Mobile Health Technology Laboratory, Department of Health Sciences and Technology, Zurich, Switzerland
| |
Collapse
|
9
|
Cuffless Blood Pressure Measurement Using Linear and Nonlinear Optimized Feature Selection. Diagnostics (Basel) 2022; 12:diagnostics12020408. [PMID: 35204499 PMCID: PMC8870879 DOI: 10.3390/diagnostics12020408] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Revised: 01/30/2022] [Accepted: 01/30/2022] [Indexed: 02/04/2023] Open
Abstract
The cuffless blood pressure (BP) measurement allows for frequent measurement without discomfort to the patient compared to the cuff inflation measurement. With the availability of a large dataset containing physiological waveforms, now it is possible to use them through different learning algorithms to produce a relationship with changes in BP. In this paper, a novel cuffless noninvasive blood pressure measurement technique has been proposed using optimized features from electrocardiogram and photoplethysmography based on multivariate symmetric uncertainty (MSU). The technique is an improvement over other contemporary methods due to the inclusion of feature optimization depending on both linear and nonlinear relationships with the change of blood pressure. MSU has been used as a selection criterion with algorithms such as the fast correlation and ReliefF algorithms followed by the penalty-based regression technique to make sure the features have maximum relevance as well as minimum redundancy. The result from the technique was compared with the performance of similar techniques using the MIMIC-II dataset. After training and testing, the root mean square error (RMSE) comes as 5.28 mmHg for systolic BP and 5.98 mmHg for diastolic BP. In addition, in terms of mean absolute error, the result improved to 4.27 mmHg for SBP and 5.01 for DBP compared to recent cuffless BP measurement techniques which have used substantially large datasets and feature optimization. According to the British Hypertension Society Standard (BHS), our proposed technique achieved at least grade B in all cumulative criteria for cuffless BP measurement.
Collapse
|
10
|
Chen F, Hao L, Zhu S, Yang X, Shi W, Zheng K, Wang T, Chen H. Potential Adverse Effects of Dexamethasone Therapy on COVID-19 Patients: Review and Recommendations. Infect Dis Ther 2021; 10:1907-1931. [PMID: 34296386 PMCID: PMC8298044 DOI: 10.1007/s40121-021-00500-z] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 07/06/2021] [Indexed: 12/12/2022] Open
Abstract
In the context of the coronavirus disease 2019 (COVID-19) pandemic, the global healthcare community has raced to find effective therapeutic agents against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). To date, dexamethasone is the first and an important therapeutic to significantly reduce the risk of death in COVID-19 patients with severe disease. Due to powerful anti-inflammatory and immunosuppressive effects, dexamethasone could attenuate SARS-CoV-2-induced uncontrolled cytokine storm, severe acute respiratory distress syndrome and lung injury. Nevertheless, dexamethasone treatment is a double-edged sword, as numerous studies have revealed that it has significant adverse impacts later in life. In this article, we reviewed the literature regarding the adverse effects of dexamethasone administration on different organ systems as well as related disease pathogenesis in an attempt to clarify the potential harms that may arise in COVID-19 patients receiving dexamethasone treatment. Overall, taking the threat of COVID19 pandemic into account, we think it is necessary to apply dexamethasone as a pharmaceutical therapy in critical patients. However, its adverse side effects cannot be ignored. Our review will help medical professionals in the prognosis and follow-up of patients treated with dexamethasone. In addition, given that a considerable amount of uncertainty, confusion and even controversy still exist, further studies and more clinical trials are urgently needed to improve our understanding of the parameters and the effects of dexamethasone on patients with SARS-CoV-2 infection.
Collapse
Affiliation(s)
- Fei Chen
- Department of Physiology, Jining Medical University, 133 Hehua Rd, Jining, 272067, China.
| | - Lanting Hao
- Department of Physiology, Jining Medical University, 133 Hehua Rd, Jining, 272067, China
| | - Shiheng Zhu
- Department of Physiology, Jining Medical University, 133 Hehua Rd, Jining, 272067, China
| | - Xinyuan Yang
- Department of Physiology, Jining Medical University, 133 Hehua Rd, Jining, 272067, China
| | - Wenhao Shi
- Department of Physiology, Jining Medical University, 133 Hehua Rd, Jining, 272067, China
| | - Kai Zheng
- Department of Physiology, Jining Medical University, 133 Hehua Rd, Jining, 272067, China
| | - Tenger Wang
- Department of Physiology, Jining Medical University, 133 Hehua Rd, Jining, 272067, China
| | - Huiran Chen
- Department of Physiology, Jining Medical University, 133 Hehua Rd, Jining, 272067, China
| |
Collapse
|
11
|
Sato T. Commentary: Assessment of Hypertension Using Clinical Electrocardiogram Features: A First-Ever Review. Front Med (Lausanne) 2021; 8:691330. [PMID: 34291065 PMCID: PMC8287056 DOI: 10.3389/fmed.2021.691330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 06/14/2021] [Indexed: 11/13/2022] Open
Affiliation(s)
- Tatsuya Sato
- Department of Cellular Physiology and Signal Transduction, Sapporo Medical University School of Medicine, Sapporo, Japan.,Department of Cardiovascular, Renal, and Metabolic Medicine, Sapporo Medical University School of Medicine, Sapporo, Japan
| |
Collapse
|